VSG 7.2.0 - Release notes

BT-SC/PAS4-MKP

VSG 7.2 Release Note enUS 74267901963
VSG 7.2.0 - Release notes
Author: Verhaeg Mario (BT-VS/PAS4-MKP) Date: 20 August, 2020

VSG 7.2.0 - Release notes
1 VSG Version 7.2.0
1.1 Introduction 1.2 Installation notes 1.3 New functionality 1.4 Resolved issues 1.5 Known issues
2 ONVIF Camera Event Driver Tool 1.1.0
2.1 Introduction 2.2 New functionality 2.3 Resolved issues 2.4 Known issues
3 VSG Version 7.1.0
3.1 Introduction 3.2 Installation notes 3.3 New functionality 3.4 Resolved issues 3.5 Known issues
4 ONVIF Camera Event Driver Tool 1.0.0
4.1 Introduction 4.2 New functionality 4.3 Resolved issues 4.4 Known issues
5 VSG Version 7.0.2
5.1 Introduction 5.2 Installation notes 5.3 New functionality 5.4 Resolved issues 5.5 Known issues
6 VSG Version 6.45
6.1 Introduction 6.2 Installation notes 6.3 New functionality 6.4 Resolved issues 6.5 Known issues
7 VSG Version 6.44
7.1 Introduction 7.2 Installation notes 7.3 New functionality

2 of 17
4
4 4 4 4 4
6
6 6 6 6
7
4 4 4 4 4
9
6 6 6 6
10
4 4 4 4 4
13
4 4 4 4 4
16
4 4 4

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes
7.4 Resolved issues 7.5 Known issues

3 of 17
4 4

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

4 of 17

1 VSG Version 7.2.0

1.1 Introduction
The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Video Streaming Gateway (VSG) 7.2.0 introduces new functionality and resolves issues. VSG 7.2.0 is tested and released with BVMS 10.1. The list of tested cameras with BVMS 10.1 can be found on the Bosch Building Technologies knowledge base. The VSG is included in the BVMS installation package.

1.2 Installation notes
Password protection is not enforced during installation and configuration of the Video Streaming gateway and it's instances. It is recommended to set a password for the service-, user- and live user for each installed instance manually to protect the devices for unauthorized access. Due to the required performance, it is not recommended to install VSG within a virtual environment. Unexpected issues, for example recording gaps, might arise when the virtual machine does not get the required (virtual) resources.

1.3 New functionality

Build 7.2.0.44 7.2.0.44 7.2.0.44 7.2.0.44 7.2.0.44 7.2.0.44

ID 235263 240014 243178 247639 250987 268512

Description Generic events (planned to be implemented in BVMS 11.0). Log camera configuration changes. Distinguish events from multi-sensor cameras (event mapping AND/OR support). GOP length up to 255 can be set to ONVIF cameras. Enhanced system events. Hyper-v virtualization and fail-over cluster tested.

1.4 Resolved issues

Build 7.2.0.44

ID 263663

(FIXED) Closed HTTP listener as this was not used.

7.2.0.44 7.2.0.44 7.2.0.44

273701 273084 251797

(FIXED) VSG setup executes "net.exe" if this file is present in the working directory. (FIXED) VSG is not able to stream video from Panomera Streaming Service (PSS). (FIXED) Cameras are no longer accessible after repair installation.

1.5 Known issues

Known issues Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

Build 7.2.0.44

ID 271253

Description VSG was not found in BVMS scan dialogue.

5 of 17

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

6 of 17

2 ONVIF Camera Event Driver Tool 1.1.0

2.1 Introduction
The ONVIF Camera Event Driver Tool is responsible for mapping custom events, coming from ONVIF cameras, into available BVMS events. The tool can be started from the BVMS Configuration Client (right click on a VSG instance).

2.2 New functionality

Build 1.1.0.22

ID 243178

Description Distinguish events from multi-sensor cameras (event mapping AND/OR support).

2.3 Resolved issues

Build

ID

1.1.0.22 n/a

n/a

2.4 Known issues

Known issues Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Build

ID

1.1.0.22 n/a

Description n/a

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

7 of 17

3 VSG Version 7.1.0

3.1 Introduction
The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Video Streaming Gateway (VSG) 7.1.0 introduces new functionality and resolves issues. VSG 7.1.0 is tested and released with BVMS 10.0.1. The list of tested and certified cameras with BVMS 10.0.1 can be found on the Bosch Building Technologies knowledge base. The VSG is included in the BVMS installation package.

3.2 Installation notes
Password protection is not enforced during installation and configuration of the Video Streaming gateway and it's instances. It is recommended to set a password for the service-, user- and live user for each installed instance manually to protect the devices for unauthorized access. Due to the required performance, it is not recommended to install VSG within a virtual environment. Unexpected issues, for example recording gaps, might arise when the virtual machine does not get the required (virtual) resources.

3.3 New functionality

Build 7.1.0.43 7.1.0.43 7.1.0.43

ID 236593 238293 239128

Description
Manual switch between ONVIF Profile S and ONVIF Profile T.
Enhance the VSG installer.
Event mapping should be customizable (interface to support the ONVIF Camera Event Driver Tool).

3.4 Resolved issues

Build 7.1.0.43

ID 239841

FIXED: lost video packets during iSCSI path fail-over.

3.5 Known issues

Known issues Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Build 7.1.0.43

ID 250929

7.1.0.43 205061

7.1.0.43 215995

Description
When using a multi-sensor camera, some events (for example, a motion event) are triggered on a camera level and the system cannot determine the sensor that triggered the event.
In some situation the VSG might crash when an Arecont Vision camera is connected. Arecont Vision cameras are not ONVIF Profile S compliant.
The VSG cannot receive the stream from Sony cameras with FW 3.1.0. Workaround: disable audio back channel on the camera.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

Build 7.1.0.43

ID 220665

7.1.0.43 220672

7.1.0.43 224867

7.1.0.43 249986

8 of 17
Description Using RTSP over HTTP/HTTPS with Panasonic cameras has reconnection issue every 2 mins interval. Workaround: disable HTTPS. Using RTSP over HTTP/HTTPS with Yokogawa cameras has reconnection issue every 2 mins interval. Workaround: disable HTTPS. VSG sometimes stops receiving events from Samsung SNP-L6233 camera. This issue cannot be observed with other Samsung cameras. Basic authentication is not a supported ONVIF authentication method and is therefore removed from the VSG. Cameras should be configured with digest authentication.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

9 of 17

4 ONVIF Camera Event Driver Tool 1.0.0

4.1 Introduction
The ONVIF Camera Event Driver Tool is responsible for mapping custom events, coming from ONVIF cameras, into available BVMS events. The tool can be started from the BVMS Configuration Client (right click on a VSG instance).

4.2 New functionality

Build

ID

1.0.0.201 n/a

Description n/a

4.3 Resolved issues

Build

ID

1.0.0.201 n/a

n/a

4.4 Known issues

Known issues Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Build

ID

1.0.0.201 207822

Description The ONVIF mapping tool can only connect to the VSG using a secure connection.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

10 of 17

5 VSG Version 7.0.2

5.1 Introduction
The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 7.0.2 introduces new functionality and resolves issues.
VSG 7.0.2 is tested and released with BVMS 10.0. List of tested and certified cameras with BVMS 10.0 can be found on the Bosch Building Technologies community.

5.2 Installation notes
Please note:
Password protection is not enforced during installation and configuration of the Video Streaming gateway and it's instances. It is recommended to set a password for the service-, user- and live user for each installed instance manually to protect the devices for unauthorized access.

5.3 New functionality

Build 7.0.2 7.0.2 7.0.2 7.0.2 7.0.2 7.0.2 7.0.2

ID 204382 206406 209373 209597 216441 197262 236526

Description Support streaming of ONVIF profile T cameras Encrypted communication from VSG to ONVIF cameras Configure TCP/unicast/multicast streaming protocol of ONVIF cameras to VSG Logging improvements for troubleshooting Move to 64-bit software architecture ONVIF profile S and T event handling Telnet access to the system is disabled by default

5.4 Resolved issues

Build 7.0.2

ID 214494

7.0.2

216177

7.0.2

216536

7.0.2

215005

7.0.2

215074

7.0.2

214487

FIXED: [Dahua] RTSP cameras stay disconnected after VSG restart, but become connected after BVMS activation
FIXED: [Sony SNC-DH240T] Camera always shows No Cam image
FIXED: [Pelco IMM12027] Camera is unable to stream
FIXED: [Avigilon H5] Unable to stream camera, due to RTSP bad request
FIXED: [Illustra PRO 12MP Fisheye] Camera is online but unable to get video stream.
FIXED: [Dahua] RTSP unauthorized even though ONVIF authentication is disabled on camera. Note: ONVIF authentication must be enabled in the camera, basic authentication is not from VSG 7.0 onwards

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

11 of 17

Build 7.0.2 7.0.2 7.0.2 7.0.2 7.0.2

ID 220343 229084 229154 229266 198892

7.0.2

198898

7.0.2

217544

7.0.2

217545

FIXED: [SAMSUNG XNP-6370RH] Audio G726 and AAC crashes OC
FIXED: JPEG cameras cannot reconnect after disconnection
FIXED: [Hikvision] Unable to stream as JPEG camera
FIXED: JPEG cameras toggles online-offline when not streaming
FIXED: Avigilon Cameras ONLINE and OFFLINE at VSG. Note: camera must be configured to stream unicast to work with VSG
FIXED: Arecont camera not working as ONVIF camera. Note: camera must be configured to stream unicast to work with VSG
FIXED: Pelco IMM12027 using multicast does not stream. Note: camera must be configured to stream unicast to work with VSG
FIXED: Avigilon H5 Using multicast does not stream. Note: camera must be configured to stream unicast to work with VSG

5.5 Known issues

Known issues Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Build 7.0.2

ID 249986

7.0.2

n/a

7.0.2

198890

7.0.2

215995

Description
Basic authentication is not a supported ONVIF authentication method and is therefore removed from the VSG. Cameras should be configured with digest authentication.
Password protection is not enforced during installation and configuration of the Video Streaming gateway and it's instances. It is recommended to set a password for the service-, user- and live user for each installed instance manually to protect the devices for unauthorized access.
Under certain circumstances replaying video from Sony 4k cameras can show corrupt images when repositioning in time line
Sony cameras streaming not working with firmware 3.1.0 when audio upload option is enabled in the camera. When disabling the audio upload option in the camera setting, stream to VSG is working.

7.0.2

226689

In case of ignoring the VSG error message in BVMS, that the max number of I/O devices is reached, VSG will not receive an updated configuration. Workaround: Reducing the number of I/O devices to max. 255.

7.0.2

229265, 235491, Adding Dahua, Hikvision and Vivotek cameras as JPEG cameras and using a high resolution

235512

JPEG image does not work with VSG 7.0, Workaround: Reduce resolution of JPEG image

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

Build 7.0.2

ID 234590

7.0.2

n/a

12 of 17
Description Under certain circumstances the VSG service keeps restarting if not TCP socket resources are available during start up Enabling telnet via CM-LIB and BVMS Config Client is not supported for VSG 7.0.2, please contact Bosch tech support to enable telnet access if necessary

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

13 of 17

6 VSG Version 6.45

6.1 Introduction
The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 6.45.5 introduces new functionality and resolves issues.
VSG 6.45 is tested and released with BVMS 9.0. List of tested and certified cameras with BVMS 9.0 can be found on the B osch Building Technologies community.

6.2 Installation notes
Please note:
Password protection is not enforced during installation and configuration of the Video Streaming gateway and it's instances. It is recommended to set a password for the service-, user- and liveuser for each installed instance manually to protect the devices for unauthorized access.

6.3 New functionality

Build 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5 6.45.5

ID 208217 208217 208217 208217 208217 208217 208217 208217 208217 208217 208217 208217 208217 208217 208217 208217 208217

Description Execute certification tests for Axis firmware 8.30.1.1 Execute certification tests for Axis M2026-LE Mk II Execute certification tests for Axis P3374-V Execute certification tests for Axis Q3517 Execute certification tests for Axis M3058 Execute certification tests for Axis firmware 6.50.2.3 Execute certification tests for Axis P1428-E Execute certification tests for Axis Q6115-E Execute certification tests for Axis Q8665-LE Execute certification tests for Axis firmware 5.51.5.1 Execute certification tests for Axis M3025 Execute certification tests for Axis M5013 Execute certification tests for Axis Q1921 Execute certification tests for Axis firmware 8.30.1 Execute certification tests for Axis Q1941-E Execute certification tests for Canon VB-H45 Execute certification tests for American Dynamics cameras

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

14 of 17

6.4 Resolved issues

Build 6.45.5

ID 210481

6.45.5

210496

6.45.5

210417

6.45.5 6.45.5

210961 210616

Description
FIXED:Hikvision: If DHCP is used for IP-address assignment, recording and live streaming is not working
FIXED:Dahua: If ONVIF authentication on camera settings is enabled, it will not be reachable in BVMS
FIXED:Dahua: Adding more than 1 ONVIF cameras result in disconnection every 10 seconds interval
FIXED:Alarm based alarm recording stops after 32 alarms
FIXED:Null execption when deleting camera from configuration when RTP looging is enabled

6.5 Known issues

Known issues Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Build

ID

n/a

179513 197601 210896 n/a n/a n/a

Description
Password protection is not enforced during installation and configuration of the Video Streaming gateway and it's instances. It is recommended to set a password for the service-, user- and liveuser for each installed instance manually to protect the devices for unauthorized access.
Event subscription is not working for Bosch VideoJetX40-SN when added as a ONVIF device to VSG
Motion/VCA Events cannot be configured and triggered separately for each video channel ´zone´ key/data-parameter ignored. This applies for all multi sensor cameras.
Switching of resolution displays distorted image
Recording of video analytics metadata only supported for Bosch cameras when using the RCP+ protocol
H.265 supported for cameras connected via RTSP protocol, for ONVIF cameras H.265 is only supported if provided as media1 profile
Audio on some 3rd Party cameras not fully supported which may result in non-availability of audio streams

n/a

Motion JPEG uses the framerate as configured in the camera.

n/a

The maximum I-frame distance must not exceed 60; for backwards replay the I-frame

distance must not exceed 30.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

Build

ID

n/a

n/a

n/a

15 of 17
Description When adding a Bosch camera to the video streaming gateway, the metadata generated by the video content analysis is always recorded. During establishing a live connection no i-frame is requested: the live connection is established after the first i-frame is received.
RTSP timeout handling like in Onvif handling (SET_PARAMETER) - some older cameras may not support this.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

16 of 17

7 VSG Version 6.44

7.1 Introduction
The latest version of the Release Notes is always available on the Bosch Security Systems Product Catalog. Version 6.44.0022 introduces new functionality and resolves issues.
List of tested and certified cameras with BVMS 9.0 can be found on the Bosch Building Technologies community.

7.2 Installation notes
Not applicable.

7.3 New functionality

Build

ID

0022

n/a

0022

n/a

0022

n/a

0022

n/a

0022

n/a

Description Motion Recording supported on DIVAR IP 5000 for Sony cameras Axis P3707-PE multi sensor camera tested Pelco IMM12027 multi sensor camera tested Samsung PNM-9081VQ multi sensor camera tested Vivotek MS8391-EV multi sensor camera tested

7.4 Resolved issues

Build 0022 0022 0022 0022

ID 176342 189306 197489 197490

Description FIXED: ONVIF/RTSP - device send no audio via rtsp FIXED: Too much log entries for JPEG cameras FIXED: [ONVIF] AXIS multi sensor quad camera AXIS P3707-PE not recording on VSG FIXED: [Pelco IMM12027] Camera does not work in current BVMS

0022

198017

0022

201439

FIXED: [Axis] Recording issue with Multi Channel encoder M-7014
FIXED: [Axis] [BVMS] Unable to retrieve event properties in OnvifEncoderEvents page (Custom port)

7.5 Known issues

Known issues Known issues are inherited by previous versions. If an issue is fixed, it will appear in the list of resolved issues. The issue IDs can be used to relate an issue to a resolution.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.

VSG 7.2.0 - Release notes

Build

ID

0022

n/a

0022

n/a

0022

n/a

0022

n/a

0022

n/a

0022

n/a

0022

n/a

0022

n/a

17 of 17
Description Recording of video analytics metadata only supported for Bosch cameras when using the RCP+ protocol H.265 supported for cameras connected via RTSP protocol, for ONVIF cameras H.265 is only supported if provided as media1 profile Audio on some 3rd Party cameras not fully supported which may result in non-availability of audio streams
Motion JPEG uses the framerate as configured in the camera.
The maximum I-frame distance must not exceed 60; for backwards replay the I-frame distance must not exceed 30. When adding a Bosch camera to the video streaming gateway, the metadata generated by the video content analysis is always recorded. During establishing a live connection no i-frame is requested: the live connection is established after the first i-frame is received.
RTSP timeout handling like in Onvif handling (SET_PARAMETER) - some older cameras may not support this.

Copyright Robert Bosch GmbH. All rights reserved, also regarding any disposal, exploration, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.


RealObjects PDFreactor(R) 10.1.10722.8, Serial No: 3945, Licensed for: K15t GmbH RealObjects PDFreactor(R) 10.1.10722.8, Serial No: 3945, Licensed for: K15t GmbH