File info: application/pdf · 246 pages · 14.87MB
PowerLogic
• Power availability • Demand response / load. curtailment. Version: 1.0 - 22/01/2020 ... Custom animated graphics Manual/automatic reports. Characteristics.
Energy management, revenue metering and power quality monitoring
Extracted Text
PowerLogicTM Electrical network management Energy management, revenue metering and power quality monitoring www.schneider-electric.com POWERLOGIC CATALOG Contents Introduction to PowerLogic Product panorama Current transformers Clicking on a Commercial Reference Number or scanning the product's QR Code links you to further product information on www.schneider-electric.com Panel instruments Basic energy metering IEM2000 series and IEM3000 series Basic multi-function metering ION6200, PM3000 series, PM5350 and PM5000 series Advanced metering PM8000 series and ION9000 series Advanced utility metering ION7400, ION8650 and ION8800 Multi-circuit metering BCPM, EM4000 series, EM4800, and EM4900 Retrofit products EM3500 and EM4200 Communications and gateways Link150, Com'X 210, Com'X 510 and ION7550 RTU Insulation monitoring devices Vigilohm insulation monitoring devices Commercial reference numbers INTRODUCTION 3 7 15 32 43 58 106 129 159 195 209 236 241 2 Version: 1.0 - 22/01/2020 PLSED309005EN_01a POWERLOGIC CATALOG INTRODUCTION PowerLogicTM System is... Schneider Electric believes every business can increase productivity while consuming less and achieving energy savings of 10% to 30%. Saving energy reduces costs and pollution, but you need the tools to uncover all opportunities, avoid risks, track progress against goals, and verify success. Schneider Electric provides these tools via the world's most advanced energy intelligence technology: PowerLogic. A PowerLogic system of meters, software and power quality solutions help manage all energy assets, every second of the day. A PowerLogic system enables all stakeholders, from CEO to facility and engineering managers, to respond quickly to potential problems and manage energy in financial and environmental terms. PowerLogic technology delivers the key performance indicators and analytics that you need to strategically balance emissions, efficiency, reliability and cost. PowerLogic technology forms one part of your total energy management solution from Schneider Electric. As the global energy management specialist, we offer endto-end power, building and process management solutions that help you optimize energy use and costs, improve performance, enhance comfort and safety, and deliver uninterrupted service while taking responsible care of our planet. Our expert services can help you audit your energy use and build your energy action plan. From power factor correction systems, harmonic filtering and variable speed drives to HVAC and lighting controls, we offer a complete range of energy efficient technologies. Version: 1.0 - 22/01/2020 3 PLSED309005EN_01a POWERLOGIC CATALOG Gain energy insight and control with PowerLogicTM systems INTRODUCTION Cutting-edge technology to increase profitability PowerLogic technology converts the complex dynamics governing the relationship between power generation and distribution on the utility side, and energy consumption, cost and reliability on the consumer side, into timely, easily understood information. Businesses can use this powerful to improve tactical actions and strategic decision making. From a single facility to an entire enterprise, PowerLogic meters monitor key distribution points 24 hours a day. Whether from generators, substations, service entrances, mains, feeders, loads or 3rd party equipment and systems, PowerLogic technology tracks, records and reports all real-time conditions and historical performance data. Intuitive web-based interfaces give stakeholders access to this data as well as advanced analytics, alarm annunciation and control capabilities. It supports comprehensive energy management programs by tracking performance and empowering you to make effective decisions. Demand Power availability and reliability � Validate that power quality complies with the energy contract � Identify power quality issues and fix them quickly with reliable mitigation solutions � Improve response to p ower-related problems � Leverage existing infrastructure capacity and avoid over-building � Support proactive maintenance to prolong asset life Supply Energy availability and reliability � Improve T&D network reliability � Enhance substation automation � Maximize the use of your existing infrastructure Revenue metering a nd power quality � Maximize metering accuracy at all interchange points � Verify compliance with new powerquality standards � Analyse and isolate the sourceof power quality problems Energy efficiency and cost savings � Measure efficiency, reveal opportunities and verify savings � Manage greenhouse gas emissions � Allocate energy costs to departments or processes � Reduce peak demand and power factor penalties � Enable participation in loadcurtailment programs (e.g. demand response) � Strengthen rate negotiation with energy suppliers � Identify billing discrepancies � Sub-bill tenants for energy costs 4 Version: 1.0 - 22/01/2020 PLSED309005EN_01a POWERLOGIC CATALOG Market segments INTRODUCTION Industry From finance to engineering, PowerLogic technology gives industry professionals the energy intelligence and control they need to support strategic decisions and establish best energy practices. It will help you reduce operational costs and meet new emissions standards without compromising production schedules or product quality. Key points are monitored throughout your power distribution, building and backup systems. Enterpriselevel software helps you maximize the use of your existing energy assets, increase energy efficiency and avoid demand or power factor penalties. Use it to uncover and solve hidden power problems that can shorten equipment life or cause costly downtime. � Cost allocation � Procurement optimization � Power factor correction � Continuity of service even in case of an earth fault Buildings Building managers through operations staff can cut energy and maintenance costs without effecting the comfort or productivity of their tenants, employees, students, patients or customers. A PowerLogic system will track all utilities and equipment conditions, and enterpriselevel software will help you analyse and improve electrical reliability. You can forecast energy requirements, optimize multi-site contracts and accurately allocate or sub-bill costs. Key performance indicators help you find and sustain energy savings, reduce emissions and meet "green" building standards in order to increase asset value and attract or retain tenants.. � Tenant sub-billing � Power availability � Cost allocation � Demand response / load � Energy efficiency & curtailment benchmarking � Procurement optimization Version: 1.0 - 22/01/2020 5 PLSED309005EN_01a POWERLOGIC CATALOG INTRODUCTION Utilities Today's energy market is more complex than ever before. Whether you generate, transmit or distribute electricity, more stakeholders need shared access to timely, accurate energy data from more exchange points and you need to maintain power availability and reduce price volatility in the face of rising demand and transmission congestion. A PowerLogic energy information system helps you meet all of these challenges by: � Metering all key interchange points with the highest possible accuracy � Improving the quality of power delivered to your customers � Ensuring the reliability and efficiency of your network and equipment From advanced energy and power quality metering systems to enterprise-level analytic software and power quality mitigation solutions, PowerLogic systems deliver business-critical information that conventional metering, SCADA and billing systems cannot. It gives you the energy intelligence and control needed to track performance, stay informed of critical conditions and empower you to make strategic decisions. It will help you increase reliability, maximize the use of resources and improve service. Critical infrastructure PowerLogic technology helps keep your systems operating continuously and securely with an economical supply of energy. Whether you manage data, communication, transportation or environmental services, minimising the risk of power-related downtime and keeping costs under control is a priority. A PowerLogic system monitors all power and cooling systems, accurately tracks their energy consumption, and allows you to identify and fix power quality issues as soon as they arise. Enterprise-level software delivers insightful diagnostics and metrics to help verify the reliability of your backup systems and maximize the use of existing capacity to defer new capital investments. You can also reveal energy inefficiencies and strengthen energy procurement across multiple sites. � Infrastructure optimization � Power quality analysis compliance � Alarming and event notification � Energy efficiency � Cost allocation � Procurement optimization � Revenue metering � Power quality monitoring � Power availability and reliability � Insulation monitoring 6 Version: 1.0 - 22/01/2020 PLSED309005EN_01a POWERLOGIC CATALOG Panorama of the PowerLogic range Use this panorama to select the most efficient products for your application needs PANORAMA Current transformers Panel Instruments CTs Ip / 5 A Name iAMP iVLT AMP/VLT iFRE iCH/iCI current transformer Function ammeter, voltmeter ammeter, voltmeter frequency meter hour counter pulse counter Installation binsulated cable, Applications diameter 21 to 35 mm, Panel instrumentation through transformer Panel instrumentation I / U I / U I / U F hours/pulses bbusbar through transformer bcable connections Energy efficiency & cost Sub-billing & cost allocation Demand & load management Billing analysis Power availability & reliability Compliance monitoring Sag/swell, transient Harmonics Revenue metering Revenue meter Characteristics btransformation ratio: 40/5 A to 6000/5 A baccuracy: class 0.5 to 3 bmaximum rated operational voltage: 720 V AC btropicalised Characteristics Measurement accuracy Installation Measurement Communication ports Inputs / Outputs Class 1.5 DIN rail 4 x 18 mm modules � 0.5 % � 1 digit DIN rail 2 x 18 mm modules Class 1.5 flush mounted 72 x 72 mm 96 x 96 mm iAMP: 30 A direct or external CT iVLT: 600 V AC direct or external VT VLT: 500 V AC direct or external VT AMP: external CT � 0.5 % � 1 digit DIN rail 2 x 18 mm modules iCI, iCH: DIN rail 2 x 18 mm modules CH: flush mount 400 V AC direct Memory capacity page 15 page 32 page 32 page 34 page 33 page 33 Version: 1.0 - 27/01/2020 7 PLSED309005EN_01b POWERLOGIC CATALOG Panorama of the PowerLogic range (cont'd) PANORAMA Basic energy metering Basic multi-function metering Name Function iEM2000/ iEM2010/ iEM2000T/ iEM2100 kilowatt-hour meters iEM3000 Series kilowatt-hour meters Applications Panel instrumentation Panel instrumentation E I, U, F, P, Q, S, PF, E (Power demand and current demand) ION6200 PM3000 Series PM5350 Series metering & sub-metering Class 0.5S IEC 62053-22 Class 1 IEC 62053-21 Class 2IEC 62053-23 metering & sub-metering Class 0.5S IEC 62053-22 Class 1 IEC 62053-21 Class 2IEC 62053-23 Class 0.5S IEC 62053-22 Class IEC 62053-23 Class IEC 61557-12 I, U, F, P, Q, S, PF, E (Power demand and current demand) I, U, F, P, Q, S, PF, E (Power demand and current demand) I, U, F, P, Q, S, PF, E (Power demand and current demand) Energy efficiency and cost Sub-billing & cost allocation Demand & load management Billing analysis Power availability & reliability Compliance monitoring Dip/swell, transient Harmonics Revenue metering Revenue meter Characteristics Measurement accuracy Installation Class 0.5S / Class 1 DIN rail 1, 2, 5, or 7 x 18 mm modules Class 0.5S / Class 1 DIN rail Voltage measurement 400 V AC direct Current measurement 40 to 125 A direct or external CT Communication ports 50 V to 330 V (Ph-N) 80 V to 570 V (Ph-Ph) up to 1MV AC (ext VT) external CT 1 Inputs / Outputs 2 I/O Memory capacity Class 0.5S Flush mount or DIN rail 60 V to 400 V AC L-N 103.5 to 690 V AC L-L external CT 1 2 I/O Class 0.5 DIN rail 50 V to 330 V AC (Ph-N) 80 V to 570 V AC (Ph-Ph) up to 1M V AC (ext VT) external CT 1 2 I/O Class 0.5 Flush mount 96 mm x 96 mm PM53xx 20-400 V L-N 20-690 V L-L external CT 1 2 I/O page 43 page 50 page 58 page 65 page 71 8 Version: 1.0 - 27/01/2020 PLSED309005EN_01b POWERLOGIC CATALOG Panorama of the PowerLogic range (cont'd) PANORAMA Basic multi-function (contd) Advanced metering Name Function Applications Panel instrumentation Panel instrumentation PM5000 Series metering & sub-metering Class 0.5S IEC 62053-22 Class 0.2S (PM55xx) IEC 62053-22 Class 1/2 IEC 62053-24 IEC 61557-12 I, U, F, P, Q, S, PF, E (Power demand and current demand) Energy efficiency and cost Sub-billing and cost allocation Demand and load management Billing analysis Power availability & Harmonics Dip/swell, transient Compliance monitoring Revenue metering Revenue metering PM8000 Series ION9000 energy & basic powwer quality meter IEC 62053-22 Class 0.2S ANSI C12.20 Class 0.2 IEC 61000-4-30 Class S IEC 62586-2 IEC 61557-12 PMD/Sx/K70/0.2 IEC / UL 61010-1 energy & advanced power quality meter IEC 62053-22 Class 0.1S ANSI C12.20 Class 0.1 IEC 61000-4-30 Class A IEC 62586-1 / -2 IEC 61557-12 PMD/Sx/K70/0.2 IEC / UL 61010-1 I, U, F, P, Q, S, PF, E, THD, Min/Max, harm, alarm, I/O (I, U unbalance, demand, clock/cal, dip/swell) I, U, F, P, Q, S, PF, E, THD, Min/Max, harm, alarm, I/O (I, U unbalance, demand, clock/cal, dip/swell, transients, flicker, RVC, mains signalling, 1/2 cycle RMS) dip/swell Characteristics Measurement accuracy (active energy) Installation Voltage measurement Current measurement Communication ports Inputs / Outputs Memory capacity Class 0.2S (PM55xx) Class 0.5S Flush & DIN 96 mm x 96 mm 20-400 V L-N 20-690 V L-L (PM55xx) 20-277 V L-N 35-690 V L-L (PM51/53xx) external CT 2 1DO for PM51xx 4/6 I/O PM53xx based on model 6 I/O for PM55xx 256 kb 1.1 MB (PM55xx) IEC 62053-22 Class 0.2S ANSI C12.20 Class 0.2 Flush & DIN 96 mm x 96 mm 57-400 V AC L-N 3P (100-690 V AC L-L) external CT 3 up to 27 DI, 9 DO up to 16 AI, 8 AO 512 MB IEC 62053-22 Class 0.1S ANSI C12.20 Class 0.1 Flush & DIN 160 mm x 160 mm Display 96 mm or 197 mm x 175 mm 57-400 V L-N AC or 100-690 V L-L AC external CT 4 up to 32 DI, 4 DO, 10 RO (relay) up to 16 AI, 8 AO 2 GB page 94 page 106 page 116 Version: 1.0 - 27/01/2020 9 PLSED309005EN_01b POWERLOGIC CATALOG Panorama of the PowerLogic range (cont'd) PANORAMA Advanced utility Name Function Applications Panel instrumentation Panel instrumentation ION7400 energy & basic power quality meter IEC 61557-12 IEC 62053-22 IEC 61000-4-30 Class S IEC 62586 ANSI C12.20 Class 0.2 PMD/Sx/K70/0.2 ION8650 A B C energy & power quality meter IEC 62052-11 IEC 62053-22/23 Class 0.2S IEC 61000-4-30 Class A ION8800 A B C energy & power quality meter IEC 62052-11 IEC 62053-22/23 Class 0.2S IEC 61000-4-30 I, U, F, P, Q, S, PF, E, THD, Min/Max, harm, alarm, I/O (I, U unbalance, demand, clock/cal) I, U, F, P, Q, S, PF, E (demand, minimum and maximum values) I, U, F, P, Q, S, PF, E (demand, minimum and maximum values) Energy efficiency & cost Sub-billing and cost allocation Demand and load management Billing analysis Power availability & reliability Harmonics Dip/swell, transient Compliance monitoring dip/swell Revenue metering Revenue metering Characteristics Measurement accuracy (active energy) Installation Voltage measurement Current measurement Communication ports Inputs / Outputs Memory capacity IEC 61053-22 Class 0.2S ANSI 12.20 Class 0.2S Flush & DIN rail mount 96 mm x 96 mm 57-400 V AC L-N 3P (100-690 V AC L-L) external CT 2 up to 27 DI, 9 DO up to 16 AI, 8 AO 512 MB Class 0.2S Class 0.2S ANSI socket mount 9S, 35S, 36S, 39S DIN 43862 rack and 76S; FT21 switchboard case 57-277 V L-N AC (9S, 36S); 120-480 V L-L AC (35S) 57-288 V L-N AC or 99-500 V L-L AC external CT 5 up to 22 I/O external CT 5 up to 16 I/O 10 MB 4 MB 2 MB up to 10 MB page 128 page 138 page 148 10 Version: 1.0 - 27/01/2020 PLSED309005EN_01b POWERLOGIC CATALOG Panorama of the PowerLogic range (cont'd) PANORAMA Multi-circuit metering Name Function BCPM branch circuit monitor IEC 61036 Class 1 EM4000 EM4800 EM4900 multi-circuit energy meter Class 0.5 ANSI C12.1, C12.20 Class 0.5S IEC 62053-22 multi-circuit energy meter Class 0.5 ANSI C12.1, C12.20 Class 0.5S IEC 62053-22 multi-circuit energy meter Class 0.5 ANSI C12.1, C12.20 Class 0.5S IEC 62 Applications Panel instrumentation Panel instrumentation Energy efficiency and cost Sub-billing and cost allocation Demand and load management Billing analysis Power availability and reliability Compliance monitoring Sag/swell, transient Harmonics Revenue metering Revenue meter Characteristics Measurement accuracy Installation Voltage measurement Current measurement Communication ports I, U, F, P, Q, S, PF, E (Power demand and current demand) I, U, F, P, Q, S, PF, E (Power demand and current demand) I, U, F, P, Q, S, PF, E (Power demand and current demand) I, U, F, P, Q, S, PF, E (Power demand and current demand) Class 1 (mains active energy) Class 0.5S Class 0.5S Class 0.5S Panel or enclosure Panel or enclosure Panel or enclosure Panel or enclosure 90 � 277 V L-N voltage Inputs CT strips for branch circuits and external CTs for mains 80 - 480 V AC L-L without 80 - 480 V AC L-L without PTs, PTs, Up to 999 kV with external Up to 999 kV with PTs external PTs Split- or solid-core CTs Split- or solid-core CTs 150 � 480 V AC L-L without PTs Up to 999 kV with external PTs Split- or solid-core CTs 1 for main 2 2 2 Inputs / Outputs Memory capacity Version: 1.0 - 27/01/2020 PLSED309005EN_01b 2 2 2 page 158 page 172 page 181 page 186 11 POWERLOGIC CATALOG Panorama of the PowerLogic range (cont'd) PANORAMA Retrofit products Name Function Applications Panel instrumentation Panel instrumentation Energy efficiency and cost Sub-billing and cost allocation Demand and load management Billing analysis Power availability and reliability Compliance monitoring Sag/swell, transient Harmonics Revenue metering Revenue meter Characteristics Measurement accuracy Installation Voltage measurement Current measurement Communication ports Inputs/Outputs Memory capacity 12 EM3500 DIN rail power & energy meter ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S for EM35xx models, ANSI C12.20 0.5% accuracy, IEC 62053-22 Class 0.2S for EM35xxA models EM4200 power & energy meter ANSI C12.20 0.2% IEC 62053-22 Class 0.2S I, U, F, P, Q, S, PF, E (Power demand and current demand) I, U, F, P, Q, S, PF, E (Power demand and current demand) Class 1 (mains active energy) ANSI C12.20 Class 0.2S IEC 62053-22 Class 0.2S Panel or enclosure DIN or screw, clip-on or hook UL: 90 V L-N to 600 V L-L; 890 - 480 V AC L-L CE: 90 V L-N to 300 V L EM35xxA models work 5 A to 5000 A exclusively with Rogowski coil CTs. 1 for main 2 (see Datasheet) page 196 page 202 Version: 1.0 - 27/01/2020 PLSED309005EN_01b POWERLOGIC CATALOG Panorama of the PowerLogic range (cont'd) PANORAMA Communications & gateways Insulation monitoring Devices Name Link150 Com'X 210 Com'X 510 ION7550 RTU Function Modbus Serial to Modbus TCP/IP protocol gateway Modbus gateway plus Energy Server and Cloud connector Ethernet gateway-server + onboard I/O Features RS-485 / Ethernet gateway Devices supported Web server with standard HTML pages Web server with custom HTML pages Real time data Ethernet Gateway Ethernet Gateway All Modbus devices 100+ known Schneider Electric devices and the ability to create custom Modbus models. EM3000 Series, iEM3000 Series, Acti9 Smartlink Masterpact, PM5000 Series, Compact NSX, iEM1, iEM2000 series, PM3000 Series, PM5350, PM5000, PM8000, ION9000, CM4000 ION8800, ION9000, Modbus devices PM5350 PM5000 PM8000 Configuration only Com'X 510 - full support Com'X 210 - config. only Custom web page support Available on Com'X 510 Historical data Automatic notification Alarm and event logs Waveform display Custom animated graphics Manual/automatic reports Characteristics Ethernet ports Modbus TCP/IP protocol RS-485 (2-wire / 4-wire) ports, Modbus protocol Number of devices connected directly RS-232 configuration ports Miscellaneous Installation Com'X 510 onboard storage Com'X 210 - publish to database server Event Notification to FI RTU includes alarm and event logs 2 (switch mode 2 only) 2w/4w - 1 (rj45) 1 10/100 Base TX port 3 32 64 devices/32 max 64 Modbus, 2 analog sensors 1 1 Serial line to Connectivity: WiFi, Ethernet Ethernet, Zigbee, GPRS, connectivity - serial + 3G or Ethernet master modem port I/O (20 I/ 12 O) 9 DIN rail DIN rail DIN 192 cutout 186 x 186 mm VigilohmTM Insulation monitoring devices Insulation monitoring for IT / Ungrounded networks RS-485 Insulation Monitors: IM9, IM9-OL, IM10, IM20 IM10-H, IM20-H, IM400 series IM400THR Insulation Fault Locators: IFL 12, IFL 12C, IFL 12MC, IFL 12H Accessories: Including voltage adaptors, cardews, toroids Available on product supervision e.g.PME, Com'X 510 Available on product supervision e.g.PME, Com'X 510 Available in supervision PME Available in supervision PME An IT earthing system -also called ungrounded system- allows the network to operate even in the presence of an insulation fault, without endangering people or property. Required as part of the IT network, an Insulation Monitoring Device (IMD) detects the insulation fault and locates it so it can be repaired. page 211 page 215 page 225 page 235 Version: 1.0 - 27/01/2020 13 PLSED309005EN_01b CURREBT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS Current transformers Schneider Electric is the global specialist in energy management with the most complete power monitoring product line. Current Transformers are essential components designed to be used with Schneider Electric's extensive power monitoring product portfolio. From simple energy meters to world class power quality meters, these proven products satisfy any requirement. 056854NMD-2 PB100316-35 056852NMD-2 PB119864 PB119870 METSECT5CC04 METSECT5MB025 METSECT5CYL1 14 METSECT5GD025 METSECT5HA025 Version: 1.0 - 24/01/2020 PLSED309005EN_02 DB416186 CURRENT TRANSFORMERS Ip/5 A ratio Application diagram of a CT. FUNCTIONS AND CHARACTERISTICS The Ip/5 A ratio current transformer delivers at the secondary a current (Is) of 0 to 5 A that is proportional to the current measured at the primary (Ip). This allows them to be used in combination with measurement equipment: � Ammeters. � Kilowatt-hour meters. � Measurement units. � Control relays. � etc. When the primary is energized, the measurement equipment nearly acts as a short circuit which keeps the secondary voltage very low. This voltage will increases significantly if the short circuit is removed. CT selection - conductor rating aspects The choice depends on the conductor profile and the maximum intensity of the primary circuit. CT with let-through primary Conductor type Suggested Current Transformer and mounting DB415986 Cable DB415920 Mixed, bars or cables DB415988 Vertical or horizontal bars DB415989 Vertical bars DB415987 DB415921 Ratings (A) CT internal profile 40 to 250 Type C FF C FF MD FF MA 150 to 800 Type M 200 to 4000 Type D (1) FF D MA MB MC FF V2 5000 to 6000 Type V MD VV (1) Two secondary connectors (parallel internal wiring - only one secondary winding) for easier cable access. 1 lateral + 1 on one extremity. Warning: only one must be used at a time. Specific mounting: use of cylinder A cylindrical metallic spacer ensures a proper CT positioning when the conductor or the CT cannot be positioned perpendicular. Secured by bolt + nut. CT with primary connection by screw and nut (example: use of cylinder with bar or cable) DB416006 DB416005 NOTE: This document is not intended to be used as an installation guide. Version: 1.0 - 24/01/2020 PLSED309005EN_02 METSECT5CYL1 (aluminium) 16550 (brass) 15 CURREBT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS CT selection - Electrical aspect Ip/5 A � We recommend that you choose the ratio immediately higher than the maximum measured current (In). Example: In = 1103 A; ratio chosen = 1250/5. � For small ratings: From 40/5 to 75/5 and for an application with digital devices, we recommend that you choose a higher rating, for example 100/5. This is because small ratings are less accurate and the 40 A measurement, for example, will be more accurate with a 100/5 CT than with a 40/5 CT. � Specific case of the motor starter: to measure motor starter current, you must choose a CT with primary current Ip = Id/2 (Id = motor starting current). Validation of measurement solution according to accuracy class It consists in controlling the right adaptation of the CT on the accuracy class aspect. The accuracy class is specified in the project. The total dissipated power of the measurement circuit (meter + cables) should not be superior to the specified limit of the CT. This limit is for different standard classes. If necessary, the choice of the cable section, the CT or meter should be modified to fit the requirement. Copper cable cross-section (mm2) 1 1.5 2.5 4 6 10 16 Power per doubled meter at 20 �C (VA) 1 0.685 0.41 0.254 0.169 0.0975 0.062 Schneider Electric Consumption of device the current input (VA) Ammeter 1.1 72 x 72 / 96 x 96 Analog ammeter 1.1 Digital ammeter 0.3 PM8000 0.15 PM3000 0.3 PM5000 iEM3000 For each temperature variation per 10 �C bracket, the power drawn up by the cables increases by 4 %. Application example Project specification: 200 A, in �27 mm cable, accuracy class 1. Our choice is METSECT5MA020. For this CT selected on the chart (next page), the max acceptable power is 7 VA (for "Accuracy class 1" which is specified in the project). Internal Cables profile (mm) type MA �27 Bars (mm) 10 x 32 15 x 25 Rating Ip/5 A (A) 150 200 250 300 400 Commercial reference number Accuracy class 0.5 1 3 Max. power (VA) METSECT5MA015 3 4 - METSECT5MA020 4 7 - METSECT5MA025 6 8 - METSECT5MA030 8 10 - METSECT5MA040 10 12 - Control of the conformity of the measurement chain: bb PM3000 multi-meter: 0.3 VA. bb 4 meters of 2.5 mm2, doubled wires: 0.41 x 4 = 1.64 VA. Total: 0.3 + 1.64 = 1.94 VA (< 7 VA) Conclusion: this CT is well adapted as the accuracy class will be even better than 1. FF ME Hazard Label 16 Version: 1.0 - 24/01/2020 PLSED309005EN_02 CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS PB118085 PB112446 PB112461 PB112460 PB112462 METSECT5CCppp METSECT5MBppp METSECT5MAppp METSECT5MCppp FF MD FF MC FF MA FF MB FF CC Type C - solid core current transformer (cable profile) Internal profile Cables type (mm) Bars (mm) Rating Commercial ref number Ip/5 A (A) CC �21 - 40 METSECT5CC004 50 METSECT5CC005 60 METSECT5CC006 75 METSECT5CC008 100 METSECT5CC010 125 METSECT5CC013 150 METSECT5CC015 200 METSECT5CC020 250 METSECT5CC025 Type M - current transformers (mixed: cable/bar profile) MB �26 12 x 40 250 METSECT5MB025 15 x 32 300 METSECT5MB030 400 METSECT5MB040 MA �27 10 x 32 150 METSECT5MA015 15 x 25 200 METSECT5MA020 250 METSECT5MA025 300 METSECT5MA030 400 METSECT5MA040 MC �32 10 x 40 250 METSECT5MC025 20 x 32 300 METSECT5MC030 25 x 25 400 METSECT5MC040 500 METSECT5MC050 600 METSECT5MC060 800 METSECT5MC080 MD �40 12 x 50 500 METSECT5MD050 20 x 40 600 METSECT5MD060 800 METSECT5MD080 See your Schneider Electric representative for complete ordering information. METSECT5MDppp Version: 1.0 - 24/01/2020 17 PLSED309005EN_02 PB112463 DB415926 DB415927 FF CC CURREBT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS Mounting plate installation. DIN rail mounting. Common characteristics Secondary current Is (A) Maximum voltage rating Ue (V) Frequency (Hz) Safety factor (sf) Degree of protection Operating temperature Storage temperature Compliance with standards Secondary connection (as per model) (1) Warning: some products are limited to +50�C. 5 A 720 V 50/60 Hz 40 to 4000 A: sf y 5 5000 to 6000 A: sf y 10 IP20 tropicalised range -25�C to +60�C (1) relative humidity > 95 % -40�C to +85�C IEC 61869-2 VDE 0414 by terminals for lug by tunnel terminals by screws Type C - solid core current transformer (cable profile) Internal profile Accuracy class type 0.5 1 3 Max. power (VA) Overall dimensions (refer to drawing pages for details) W x H x D (mm) Fastening mode Accessories Cylinder PB112451 PB112452 CC Dimension (mm) Commercial ref no. - - 1 44 x 66 x 37 - 1.25 1.5 - 1.25 2 bb Adapter for DIN rails. bb Mounting plate. 16550 METSECT5CYL1 Included - 1.5 2.5 2 2.5 3.5 2.5 3.5 4 3 4 5 4 5.5 6 5 6 7 MB 3 5 - 60 x 85 x 63 4 6 - bb Adapter for DIN rails. bb Mounting plate. METSECT5COVER 6 8 - MA 3 4 - 56 x 80 x 63 4 7 - bb Adapter for DIN rails. bb Mounting plate. METSECT5CYL2 METSECT5COVER 6 8 - 8 10 - 10 12 MC 3 5 - 70 x 95 x 65 5 8 - bb Adapter for DIN rails. bb Mounting plate. METSECT5COVER 8 10 - 10 12 12 15 - 10 12 MD 4 6 - 70 x 95 x 65 6 8 - bb Adapter for DIN rails. bb Mounting plate. METSECT5COVER 8 12 - See your Schneider Electric representative for complete ordering information. FF MB FF MA FF MC FF MD NOTE: This document is not intended to be used as an installation guide. 18 Version: 1.0 - 24/01/2020 PLSED309005EN_02 PB112467 FF V2 PB112454 CURRENT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS Type V - current transformers (vertical bar profile) Internal profile Cables Bars Rating Commercial reference type (mm) (mm) Ip/5 A number (A) VV - 55 x 165 5000 METSECT5VV500 g 6000 METSECT5VV600 g METSECT5VVppp PB112455 METSECT5DAppp METSECT5DCppp METSECT5DEppp PB112459 PB112457 METSECT5DBppp METSECT5DDppp METSECT5DHppp Type D - current transformers (vertical or horizontal bar - dual secondary terminals) DA 32 x 65 400 METSECT5DA040 500 METSECT5DA050 600 METSECT5DA060 800 METSECT5DA080 1000 METSECT5DA100 1250 1500 METSECT5DA125 g METSECT5DA150 g DB - 38 x 127 1000 METSECT5DB100 1250 METSECT5DB125 g 1500 METSECT5DB150 g 2000 METSECT5DB200 g 2500 3000 METSECT5DB250 g METSECT5DB300 g DC - 52 x 127 2000 METSECT5DC200 g 2500 METSECT5DC250 g 3000 METSECT5DC300 g 4000 METSECT5DC400 g DD - 34 x 84 1000 METSECT5DD100 1250 METSECT5DD125 g 1500 METSECT5DD150 g DE - 54 x 102 1000 METSECT5DE100 1250 METSECT5DE125 g DH - 38 x 102 1500 2000 1250 METSECT5DE150 g METSECT5DE200 g METSECT5DH125 g 1500 METSECT5DH150 g 2000 METSECT5DH200 g g Operating temperature: -25 �C to 50 �C See your Schneider Electric representative for complete ordering information. PB112456 PB112458 Version: 1.0 - 24/01/2020 19 PLSED309005EN_02 FF V2 CURREBT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS Type V - solid core current transformers (vertical bar profile) Internal profile Accuracy class type 0.5 1 3 Max. power (VA) Overall dimensions (refer to drawing pages for details) W x H x D (mm) Fastening mode VV Dimension (mm) . 60 - - 175 x 273.5 x 110 bb Insulated locking screw. 70 - - Accessories Cylinder - Sealable cover Included Type D - solid core current transformers (vertical or horizontal bar - dual secondary terminals) DA Dimension (mm) 4 8 - 90 x 94 x 90 bb Insulated locking screw. 8 10 - 8 12 - 12 15 - 15 20 - 15 20 20 25 - DB 6 10 - 99 x 160 x 87 bb Insulated locking screw. - 8 12 - 10 15 - 15 20 - 20 25 - 25 30 - DC 25 30 - 125 x 160 x 87 bb Insulated locking screw. - 30 50 - 30 50 - 30 50 - DD 10 15 - 96 x 116 x 87 bb Insulated locking screw. - 12 15 - 15 20 - DE 12 15 - 135 x 129 x 85 bb Insulated locking screw. - 15 20 - 20 25 20 25 - DH 12 15 - 98 x 129 x 75 bb Insulated locking screw. - 12 15 - 20 25 - g Operating temperature: -25 �C to 50 �C See your Schneider Electric representative for complete ordering information. Included Included Included Included Included Included 20 Version: 1.0 - 24/01/2020 PLSED309005EN_02 DB416965 DB415922 CURRENT TRANSFORMERS Solid core CT dimensions CC internal profile type MB internal profile type DIMENSIONS AND CONNECTION DB415923 MA internal profile type MC internal profile type DB415939 MD internal profile type DA internal profile type DB415932 DB internal profile type DC internal profile type DB416966 DB416968 DB416967 Version: 1.0 - 24/01/2020 21 PLSED309005EN_02 CURRENT TRANSFORMERS Solid core CT dimensions contd. DIMENSIONS AND CONNECTION DD internal profile type DE internal profile type DB416970 DB416969 DH internal profile type DB416971 VV internal profile type DB416972 NOTE: This document is not intended to be used as an installation guide. 22 Version: 1.0 - 24/01/2020 PLSED309005EN_02 DB416004 CURRENT TRANSFORMERS Solid core cylinders dimensions Cylinders METSECT5CYL1 METSECT5CYL2 DIMENSIONS AND CONNECTION DB416002 Aluminium 16550 Brass Covers METSECT5COVER DB416000 Aluminium 16551 Brass DB416082 DB416008 Version: 1.0 - 24/01/2020 23 PLSED309005EN_02 CURREBT TRANSFORMERS Split core CTs FUNCTIONS AND CHARACTERISTICS Hazard Label Common characteristics Secondary current Is (A) Maximum voltage rating Ue (V) Frequency (Hz) Safety factor (sf) Degree of protection Operating temperature Storage temperature Compliance with standards Secondary connection (as per model) Cable CT 5 A 720 V 50/60 Hz up to 1000 A: sf y 5 greater than 1000 A: sf y 10 IP20 -5�C to +50�C relative humidity 5-85 % -25�C to +70�C IEC 61869-1 IEC 61869-2 by terminals for lug by tunnel terminals by screws Bus Bar CT 5 A 720 V 50/60 Hz up to 1500 A: sf y 5 greater than 1500 A: sf y 10 IP20 -5�C to +40�C relative humidity 5-85 % -25�C to +70�C IEC 61869-1 IEC 61869-2 by terminals for lug by tunnel terminals by screws Split core CT CT internal profile Type H FF C HA HD HG HJ HP FF V2 Type G GA GD GG GJ FF HM HM 24 Version: 1.0 - 24/01/2020 PLSED309005EN_02 PB119862 PB119864 CURRENT TRANSFORMERS Split core CTs METSECT5GAppp METSECT5GDppp METSECT5GGppp FUNCTIONS AND CHARACTERISTICS Type G - split core current transformers (bus bar) Accuracy class CT window Max power (VA) dimension (mm) 0.5 1 3 Rating Ip/5A (A) Commercial Reference no. GA - - 1.25 23 x 33 100 METSECT5GA010 - - 1.5 150 METSECT5GA015 - - 2.5 200 METSECT5GA020 - 1.5 - 250 METSECT5GA025 - 3.75 - 300 METSECT5GA030 1- - 400 METSECT5GA040 GD - 1.5 - 55 x 85 250 METSECT5GD025 - 2.5 - 300 METSECT5GD030 1- - 400 METSECT5GD040 2.5 - - 500 METSECT5GD050 2.5 - - 600 METSECT5GD060 2.5 - - 750 METSECT5GD075 2.5 - - 800 METSECT5GD080 5- - 1000 METSECT5GD100 GG - 1.5 - 85 x 125 250 METSECT5GG025 - 2.5 - 300 METSECT5GG030 - 2.5 - 400 METSECT5GG040 2.5 - - 500 METSECT5GG050 2.5 - - 600 METSECT5GG060 2.5 - - 750 METSECT5GG075 2.5 - - 800 METSECT5GG080 5- - 1000 METSECT5GG100 5- - 1200 METSECT5GG120 7.5 - - 1250 METSECT5GG125 7.5 - - 1500 METSECT5GG150 GJ 10 - - 85 x 165 1000 METSECT5GJ100 10 - - 1200 METSECT5GJ120 10 - - 1500 METSECT5GJ150 10 - - 1600 METSECT5GJ160 10 - - 2000 METSECT5GJ200 10 - - 2500 METSECT5GJ250 15 - - 3000 METSECT5GJ300 15 - - 4000 METSECT5GJ400 See your Schneider Electric representative for complete ordering information. PB119866 PB119868 METSECT5GJppp Version: 1.0 - 24/01/2020 25 PLSED309005EN_02 PB119870 PB119872 CURREBT TRANSFORMERS FUNCTIONS AND CHARACTERISTICS Split core CTs contd. METSECT5HAppp METSECT5HDppp METSECT5HGppp Type H - split core current transformers (cable) Accuracyclass CT window Rating Commercial Max power (VA) dimension (mm) Ip/5A (A) Reference no. 0.5 1 3 HA - 1 - 18.4 x 19 150 METSECT5HA015 - 1.5 - 150 METSECT5HA020 1 - - HD 250 METSECT5HA025 - 1 - 27.9 x 27 250 METSECT5HD025 - 1.5 - 300 METSECT5HD030 - 2.5 - 400 METSECT5HD040 1 - - 500 METSECT5HD050 HG - - 1.5 �32.5 100 METSECT5HG010 - - 2.5 125 METSECT5HG013 - - 3 150 METSECT5HG015 - - 3 200 METSECT5HG020 - - 3 250 METSECT5HG025 - 2.5 - 300 METSECT5HG030 - 5 - 400 METSECT5HG040 - 5 - 500 METSECT5HG050 - 5 - 600 METSECT5HG060 HJ - 2.5 - 42.4 x 43 300 METSECT5HJ030 - 5 - 400 METSECT5HJ040 - 5 - 500 METSECT5HJ050 2.5 - - 600 METSECT5HJ060 2.5 - - 750 METSECT5HJ075 2.5 - - 800 METSECT5HJ080 HM - 2.5 - 42.4 x 85 300 METSECT5HM030 - 5 - 400 METSECT5HM040 - 5 - 500 METSECT5HM050 2.5 - - 600 METSECT5HM060 2.5 - - 750 METSECT5HM075 2.5 - - 800 METSECT5HM080 HP - 1.5 - �44 250 METSECT5HP025 - 2.5 - 300 METSECT5HP030 - 5 - 400 METSECT5HP040 - 5 - 500 METSECT5HP050 - 5 - 600 METSECT5HP060 - 5 - 750 METSECT5HP075 - 5 - 800 METSECT5HP080 - 5 - 1000 METSECT5HP100 See your Schneider Electric representative for complete ordering information. PB119874 PB119878 PB119880 PB119876 METSECT5HJppp 26 METSECT5HMppp METSECT5HPppp Version: 1.0 - 24/01/2020 PLSED309005EN_02 PB119863 PB119865 CURRENT TRANSFORMERS Split core CT dimensions Gx products GA Dimensions DIMENSIONS AND CONNECTION GD Dimensions GG Dimensions GJ Dimensions PB119867 PB119869 Version: 1.0 - 24/01/2020 27 PLSED309005EN_02 PB119871 PB119873 CURRENT TRANSFORMERS Split core CT dimensions contd. Hx products HA Dimensions HD Dimensions DIMENSIONS AND CONNECTION HG Dimensions HJ Dimensions PB119875 PB119877 28 Version: 1.0 - 24/01/2020 PLSED309005EN_02 CURRENT TRANSFORMERS Split core CT dimensions contd. HM Dimensions HP Dimensions DIMENSIONS AND CONNECTION PB119879 PB119881 Version: 1.0 - 24/01/2020 29 PLSED309005EN_02 CURREBT TRANSFORMERS Rogowski CTs FUNCTIONS AND CHARACTERISTICS PB118060 METSECTR30500 PowerLogic Rogowski Current Transformer Main Range Product or component type Accessory / part category Range compatibility Current transformer type Complementary Electrical connection Cable METSECTR30500 METSECTR46500 METSECTR60500 METSECTR90500 PowerLogic Current transducer Measurement accessory PowerLogic EM3500 - EM3555A EM3502A EM3560 EM3550A EM3560 EM3561A PowerLogic EM4200 - EM4236 EM4235 Acti9 iEM3000 - iEM3555 iEM3565 Flexible core Flying lead 2.4 m 600 V AC max, voltage L-N sensed conductor 1000 V AC UL style 21223 cable with 22 AWG leads Current range 50 A to 5000 A Network frequency 50/60 Hz Measurement accuracy �1 % from 50 A to 5000 A Installation category Pollution degree Dimensions CT core thickness METSECTR30500 8 mm diameter 600 V AC Cat IV 2 METSECTR46500 METSECTR60500 8 mm diameter 8 mm diameter METSECTR90500 8 mm diameter CT core length (open) 300 mm 460 mm 600 mm 900 mm Diameter (closed) Environment 96 mm 146 mm 191 mm 287 mm Standards Product certifications EN 61010-1, UL 61010-1, EN 61010-2-032, UL 61010-2-032 CURus UL recognized Ambient air temperature for operation -15 �C to 60 �C Ambient air temperature for storage Humidity range -40 �C to 70 �C 0 to 95 % non-condensing Altitude Protection degree 2000 m max IP67 Commercial Reference Numbers METSECTR25500 METSECTR30500 METSECTR46500 METSECTR60500 METSECTR90500 Powerlogic - Rogowski current transformer, 250 mm CT core length, 80 mm dia. CT, rope, 600 V AC, 5 kA Powerlogic - Rogowski current transformer, 300 mm CT core length, 96 mm dia. CT, rope, 600 V AC, 5 kA Powerlogic - Rogowski current transformer, 460 mm CT core length, 146 mm dia. CT, rope, 600 V AC, 5 kA Powerlogic - Rogowski current transformer, 600 mm CT core length, 191 mm dia. CT, rope, 600 V AC, 5 kA Powerlogic - Rogowski current transformer, 900 mm CT core length, 287 mm dia. CT, rope, 600 V AC, 5 kA 30 Version: 1.0 - 24/01/2020 PLSED309005EN_02 PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICS Panel instruments Schneider Electric panel instruments reliably comply with the most stringent standards, including IEC, MID, UL, etc., and we thoroughly test all products with recognized, third-party laboratories. Our products are simple to install, configure, and use. This saves our partners time and money and lets them deliver the best solutions in a timely and cost-effective manner. Whatever the size or type of application, the PowerLogicTM product line is an integral part of smart panels. DB119006 PB112024 PB101118 16029 Version: 1.0 - 24/01/2020 PLSED309005EN_03 15202 16003 31 DB119006 DB119005 PANEL INSTRUMENTS iAMP. 16029 iVLT. 16061 FUNCTIONS AND CHARACTERISTICS Function iAMP Ammeters measure the current flowing through an electric circuit in amps. iVLT Voltmeters measure the potential (voltage) difference of an electric circuit in volts. Common technical data � Accuracy: Class 1.5. � Complies with standards IEC 60051-1, IEC 61010-1 and IEC 61000-4. � Ferromagnetic device. � Pseudo-linear scale over 90�. � Ammeters (except catalog number 16029): � connection on CT, ratio In/5, to be ordered separately interchangeable dials. � Temperature: � operating temperature: -25 �C to 55 �C � reference temperature: 23 �C � Influence of temperature on accuracy: �0.03 %/�C. � Utilisation frequency: 50 Hz to 60 Hz. � Consumption: � AMP: 1.1 VA � VLT catalog number 15060: 2.5 VA � VLT catalog number 16061: 3.5 VA. � Permanent overload: � AMP: 1.2 In � VLT: 1.2 Un. � Maximum overload for 5 s: � AMP: 10 In � VLT: 2 Un. � Connection: tunnel terminals for 1.5 to 6 mm2 rigid cables. Commercial reference numbers Type iAMP with direct connection Scale Connection Width in mod. Comm. ref. with CT of 9 mm no. 0-30 A no 8 16029 iAMP with connection on CT Basic device (delivered without dial) X/5 8 Dial 0-5 A 0-50 A 50/5 0-75 A 75/5 0-100 A 100/5 0-150 A 150/5 0-200 A 200/5 0-250 A 250/5 0-300 A 300/5 0-400 A 400/5 0-500 A 500/5 0-600 A 600/5 0-800 A 800/5 0-1000 A 1000/5 0-1500 A 1500/5 0-2000 A 2000/5 iVLT 0-300 V 8 0-500 V 8 16030 16032 16033 16034 16035 16036 16037 16038 16039 16040 16041 16042 16043 16044 16045 16060 16061 See your Schneider Electric representative for complete ordering information. 32 Version: 1.0 - 24/01/2020 PLSED309005EN_03 PB112024 PB112023 PB112025 PANEL INSTRUMENTS iAMP. iVLT. 15202 15201 iFRE. 15208 FUNCTIONS AND CHARACTERISTICS Function iAMP Ammeters measure in amps the current flowing through an electric circuit. iVLT Voltmeters measure in volts the potential (voltage) difference of an electric circuit. iFRE Frequency meters measure in hertz the frequency of an electric circuit from 20 to 600 V AC. Common technical data � Supply voltage: 230 V AC � Operating frequency: 50 Hz to 60 Hz. � Display by red LED: 3 digits, h = 8 mm (0.31 in). � Accuracy at full-scale : 0.5 % �1 digit. � Consumption: max. 5 VA or rated 2.5 VA. � Degree of protection: � IP40 on front face. � IP20 at terminal level. � Connection: tunnel terminals for 2.5 mm2 cables. Specific data 10 A direct reading ammeter � Minimum value measured: 4 % of rating. � Measurement input consumption: 1 VA. Multi-rating ammeter � Ratings: � in direct reading: 5 A. � by CT (not supplied) configurable on the front face of the ammeter: 10, 15, 20, 25, 40, 50, 60, 100, 150, 200, 250, 400, 500, 600, 800, 1000, 1500, 2000, 2500, 4000, 5000 A. � Minimum value measured: 4 % of rating. � Measurement input consumption: 0.55 VA. Voltmeter � Direct measurement: 0...600 V AC � Input impedance: 2 MW. � Minimum value measured: 4 % of rating. Frequency meter � Minimum value measured: 20 Hz. � Maximum value measured: 100 Hz. � Full-scale display: 99.9 Hz. Compliance with standards � Safety: IEC/EN 61010-1. � EMC electromagnetic compatibility: IEC/EN 65081-1 and IEC/EN 65082-2. Commercial reference numbers Type Direct reading iAMP Multi-rating iAMP iVLT iFRE Scale Connection Width in mod. Comm. ref. with CT of 9 mm no. 0-10 A No 4 15202 0-5000 A As per rating 4 15209 0-600 V 4 15201 20-100 Hz 4 15208 See your Schneider Electric representative for complete ordering information. Version: 1.0 - 24/01/2020 33 PLSED309005EN_03 PB101118-30_c PB101119-30_c PB101116-30_c PANEL INSTRUMENTS AMP for standard feeder. 16009 AMP for motor feeder. 16006 16005 VLT. FUNCTIONS AND CHARACTERISTICS Function The 72 x 72 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. AMP The ammeters measure in amps the current flowing through an electrical circuit. VLT The voltmeter measure in volts the potential difference (voltage) of an electrical circuit. Common technical data � Accuracy: Class 1.5. � Compliance with standard IEC 60051-1, IEC 61010-1 and IEC 61000-4. � Ferromagnetic device. � Scale length: 62 mm over 90�. � Mounting in enclosure or in cubicle. � Degree of protection: IP52. � Maximum operating position: 30� / vertical. � Temperature: � operation: -25 �C to 50 �C. � reference: 23 �C. � Influence of temperature on accuracy: �0.003 %/ �C. � Utilisation frequency: 50 Hz to 60 Hz. AMP specific technical data � Needs a In/5 CT to be ordered separately. � Interchangeable dials to be ordered separately. � Consumption: 1.1 VA. � Permanent overload: 1.2 In. � Maximum overload for 5 s: 10 In. VLT specific technical data � Consumption: 3 VA. � Permanent overload: 1.2 Un. � Maximum overload for 5 s: 2 Un. Commercial reference numbers Type Scale AMP for standard feeder Basic device (delivered without dial) 1.3 In dial AMP for motor feeder Basic device (delivered without dial) 3 In dial VLT 0-50 A 0-100 A 0-200 A 0-400 A 0-600 A 0-1000 A 0-1250 A 0-1500 A 0-2000 A 0-30-90 A 0-75-225 A 0-200-600 A 0-500 V Connection on CT X/5 50/5 100/5 200/5 400/5 600/5 1000/5 1250/5 1500/5 2000/5 X/5 30/5 75/5 200/5 Comm. ref. no. 16004 16009 16010 16011 16012 16013 16014 16015 16016 16019 16003 16006 16007 16008 16005 See your Schneider Electric representative for complete ordering information. 34 Version: 1.0 - 24/01/2020 PLSED309005EN_03 PB101116-40_c PB101119-40_c PB101118-40_c PANEL INSTRUMENTS AMP for standard feeder. AMP for motor feeder. VLT. Version: 1.0 - 24/01/2020 PLSED309005EN_03 16079 16076 16075 FUNCTIONS AND CHARACTERISTICS Function The 96 x 96 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. AMP The ammeters measure in amps the current flowing through an electrical circuit. VLT The voltmeter measure in volts the potential difference (voltage) of an electrical circuit. Common technical data � Accuracy: class 1.5. � Compliance with standard IEC 60051-1, IEC 61010-1 and IEC 61000-4. � Ferromagnetic device. � Scale length: 80 mm over 90�. � Mounting in enclosure or in cubicle. � Degree of protection: IP52. � Maximum operating position: 30� / vertical. � Temperature: � operation: -25 �C to 50 �C. � reference: 23 �C. � Influence of temperature on accuracy: �0.003 % / �C. � Utilisation frequency: 50 Hz to 60 Hz. AMP specific technical data � Needs a In/5 CT to be ordered separately. � Interchangeable dials to be ordered separately. � Consumption: 1.1 VA. � Permanent overload: 1.2 In. � Maximum overload for 5S: 10 In. VLT specific technical data � Consumption: 3 VA. � Permanent overload: 1.2 Un. � Maximum overload for 5S: 2 Un. Commercial reference numbers Type Scale AMP for standard feeder Basic device (delivered without dial) 1.3 In dial AMP for motor feeder Basic device (delivered without dial) 3 In dial VLT 0-50 A 0-100 A 0-200 A 0-400 A 0-600 A 0-1000 A 0-1250 A 0-1500 A 0-2000 A 0-2500 A 0-3000 A 0-4000 A 0-5000 A 0-6000 A 0-30-90 A 0-75-225 A 0-200-600 A 0-500 V Connection on CT X/5 50/5 100/5 200/5 400/5 600/5 1000/5 1250/5 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5 6000/5 X/5 30/5 75/5 200/5 Comm. ref. no. 16074 16079 16080 16081 16082 16083 16084 16085 16086 16087 16088 16089 16090 16091 16092 16073 16076 16077 16078 16075 See your Schneider Electric representative for complete ordering information. 35 PANEL INSTRUMENTS FUNCTIONS AND CHARACTERISTICS Function The 48 x 48 selector switches are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. CMA The ammeter selector switch uses a single ammeter (by means of current transformers) for successive measurement of the currents of a three-phase circuit. CMV The voltmeter selector switch uses a single voltmeter for successive measurement of the voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit. Common technical data � Durability: � electrical: 100,000 operations. � mechanical: 2,000,000 operations. � AgNi contact. � Operating temperature: -25 �C to 50 �C. � Compliance with standards IEC/EN 60947-3. � Degree of protection: � IP65 on front face. � IP20 at terminal level. Commercial reference numbers Type CMA CMV Rating (A) 20 Voltage (V) 500 Number of positions 4 7 Comm. ref. no. 16017 16018 See your Schneider Electric representative for complete ordering information. Connection DB117274 DB114275 CMA. CMV. Reading 3 phase-to-earth voltages + 3 phase-to-phase voltages. Note: when connecting do not remove the pre-cabling. See appropriate Installation Guide for this product. 36 Version: 1.0 - 24/01/2020 PLSED309005EN_03 PB107119 PB107118 PANEL INSTRUMENTS iCMA. 15126 iCMV. 15125 FUNCTIONS AND CHARACTERISTICS Function iCMA This 4-position ammeter selector switch uses a single ammeter (using current transformers) for successive measurement of the currents of a three-phase circuit. iCMV This 7-position voltmeter selector switch uses a single voltmeter for successive measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit. Common technical data � Rotary handle. � Maximum operating voltage: 440 V, 50/60 Hz. � Nominal thermal current: 10 A. � Operating temperature: -20 �C to 55 �C. � Storage temperature: -25�C to 80�C. � Mechanical durability (AC21A-3 x 440 V): 2,000,000 operations. � Degree of protection: � IP66 on front face. � IP20 at terminal level. � Electrical durability: 1,000,000 operations. � Connection: jumper terminals with captive screws, for cables up to 1.5 mm2. � Complies with standards: IEC/EN 60947-3. Commercial reference numbers Type iCMA iCMV Rating (A) 10 10 Voltage (V AC) 415 415 Width in mod. of 9 mm 4 4 Comm. ref. no. 15126 15125 See your Schneider Electric representative for complete ordering information. Connection DB114272 iCMA. DB114273 iCMV. See appropriate Installation Guide for this Version: 1.0 - 24/01/2020 37 PLSED309005EN_03 PB112026 DB119003 PANEL INSTRUMENTS iCH "DIN". CH "48 x 48". 15440 15607 FUNCTIONS AND CHARACTERISTICS Function Electromechanical counter that counts the operating hours of a machine or piece of electrical equipment. Giving a precise indication of operating time, the counter is used to decide when to carry out preventive maintenance. Common technical data � Electromechanical display. � Maximum display: 99999.99 hours. � Display accuracy: 0.01 %. � Without reset. � Storage temperature: -25 �C to 85 �C. � Connection: tunnel terminals for 2.5 mm2 cable. Specific technical data iCH "DIN" � Consumption: 0.15 VA. � Operating temperature: -10 �C to 70 �C. � Mounting on DIN rail. CH "48 x 48" � Consumption: � 15607: 0.25 VA � 15608: 0.15 VA � 15609: 0.02 VA to 12 V and 0.3 VA to 36 V. � Operating temperature: -20 �C to 70 �C. � Degree of protection: IP65 on front face. � Mounting on front face of monitoring switchboards. Commercial reference numbers Type iCH "DIN" CH "48 x 48" Voltage (V) Width in mod. of 9 mm 230 V AC � 10 %/50 Hz 4 24 V AC � 10 %/50 Hz 230 V AC � 10 %/50 Hz 12 to 36 V DC Comm. ref. no. 15440 15607 15608 15609 See your Schneider Electric representative for complete ordering information. Connection DB114262 DB114263 load iCH "DIN". See appropriate Installation Guide for this load CH "48 x 48". 38 Version: 1.0 - 24/01/2020 PLSED309005EN_03 iCL.eps PANEL INSTRUMENTS iCI impulse counter 15443 FUNCTIONS AND CHARACTERISTICS Function Electromechanical counter designed to count impulses emitted by: kilowatt-hour meters, temperature overrun detectors, people meters, speed meters, etc. Common technical data � Supply and metering voltage: 230 V AC � 10 %, 50/60 Hz. � Consumption: 0.15 VA. � Maximum display: 9 999 999 impulses. � Without reset. � Metering data: � minimum impulse time: 50 ms � minimum time between 2 impulses: 50 ms. � Storage temperature: -25 �C to 85 �C. � Operating temperature: -10 �C to 70 �C. � Connection: tunnel terminals for 2.5 mm2 cable. Commecial reference numbers Type iCI Width in mod. of 9 mm 4 Comm. ref. no. 15443 Connection DB114271 load load See appropriate Installation Guide for this Version: 1.0 - 24/01/2020 39 PLSED309005EN_03 DB103473 PANEL INSTRUMENTS Analog ammeters and voltmeters iAMP, iVLT Capot de protection Digital ammeters, voltmeter and frequency meter iAMP, iVLT DIMENSIONS AND CONNECTION DB103474 iCMA and iCMV selector switches DB103475 DB103481 DB103476 72 x 72 analog ammeters and voltmeter Protection cover Terminal M4 96 x 96 analog ammeters and voltmeter Protection cover Terminal M4 See the appropriate Installation Guide for this product. 40 Version: 1.0 - 24/01/2020 PLSED309005EN_03 DB103477 DB103479 PANEL INSTRUMENTS 48 x 48 CMA and CMV selector switches 3.2 (or 4.8) 24.1 (or 33) 22.3 (or 30.5) (with adapter) iCI impulse counter and iCH hour counter DIMENSIONS AND CONNECTION 48 x 48 CH hour counters See the appropriate Installation Guide for this product. DB109825 Version: 1.0 - 24/01/2020 41 PLSED309005EN_03 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Basic energy metering Whether you require a single-phase kWh meters or full-featured, dual tariff energy meter, Schneider Electric provides iEM2xxx & iEM3xxx series meters to best fit your customer's application. � PowerLogic iEM2000 series � PowerLogic iEM2100 series � PowerLogic iEM3000 series PB108401 PB115001 PB108410 A9MEM2000 A9MEM2100 42 A9MEM3100 Version: 1.0 - 24/01/2020 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Acti9 iEM2000 Series Technical Datasheet The Acti9 iEM2000 series energy meters offer a cost-attractive, competitive range of single-phase DIN rail-mounted energy meters ideal for sub-billing and cost allocation applications. Applications � Monitor power consumption for each floor, office sector, or unit � Allocate energy costst to lower cost of operations, optimise your building's power efficiency � Connect to power management software to take full advantage of the IoT digital power installation PB105289 Version: 1.0 - 24/01/2020 PLSED309005EN_04 A9MEM2000 43 BASIC ENERGY METERING The solution for: All markets that can benefit from a solution that includes PowerLogic iEM2000 series meters: � Buildings � Industry � Data Centre & networks � Infrastructures (airport, road tunnels, telecom). Benefits The Acti9 iEM2000 series meters are economical and easy to install in panelboards and switchboards: � DIN rail mounted, compact size � Accurate data measurement with Class 1 accuracy Advantages � Active energy Class 1 accuracy, with LCD display � Modbus RS-485 and pulse output � Direct connect, self-powered � MID approved � Two tariffs FUNCTIONS AND CHARACTERISTICS Energy management system: To get the most effective use from your Schneider Electric measurement and metering devices, we offer a range of dedicated data loggers and gateways for your building energy management. Conformity of standards � IEC 62053-21 � EN 50470-3 iEM2000 feature selection iEM2000T Self-powered n Display iEM2000 n n Width (mm) 18 18 Current input Multi-tariff Communication 40 A Active Energy accuracy Class 1 IEC 62053-21 Digital outputs MID for billing application Commercial reference number 1 P/O A9MEM2000T 40 A Class 1 IEC 62053-21 Class B EN 50470-3 n A9MEM2000 See your Schneider Electric representative for complete ordering information. iEM2010 n n 18 40 A Class 1 IEC 62053-21 Class B EN 50470-3 1 P/O n A9MEM2010 iEM2050 n n (6 digit LCD) 17.5 45 A 2 tariffs Modbus Class 1 IEC 62053-21 1 P/O A9MEM2050 iEM2055 n n (6 digit LCD) 17.5 45 A 2 tariffs Modbus Class 1 IEC 62053-21 Class B EN 50470-3 1 P/O n A9MEM2055 44 Version: 1.0 - 24/01/2020 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS iEM2000 series technical specifications Technical specifications iEM2000T iEM2000 iEM2010 COMM reference number A9MEM2000T A9MEM2000 A9MEM2010 Direct connection Up to 40 A Up to 40 A Up to 40 A Pulse output operation 100 pulses/kwh (120ms long) Display capacity 999999.9 kWh Voltage range (L-N) Operating frequency Meter constant LED Wiring capacity (Power) Wiring capacity (Communications) Consumption IP protection Temperature Active energy Reactive energy Active power Reactive power Power Factor Current and voltage Frequency 184 to 276 V AC 50/60 Hz 3200 flashes per KWh 4 mm2 10 mm2 <10 VA IP40 front panel and IP20 casing -10�C to 55�C n n n iEM2050 iEM2055 A9MEM2050 A9MEM2055 Up to 45 A Up to 45 A 10000, 2000, 1000, 100, 10, 1, 0.1, 0.01 pulses/kWh 9999.99 kWh (switching to 99999.9 when over this value) 195 to 253 V AC 50 Hz 10000 flashes per KWh 2.5 mm2 8-10 mm2 IP51 front panel -25�C to 55�C n n n n n n n n n n n n n n iEM2050/iEM2055 dimensions iEM2000 dimensions PB115426 DB116734 Maximum diameter power connection clamps 8 mm2 (solid copper). See the appropriate product Installation Guide for complete instructions. Version: 1.0 - 24/01/2020 PLSED309005EN_04 Maximum diameter power connection clamps 8 mm2 (solid copper). See the appropriate product Installation Guide for complete instructions. 45 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Acti9 iEM2100 Series The Acti9 iEM2100 series energy meters are ideal for basic kWh metering and billing applications and support two protocols (Modbus and M-bus) that allow them to integrate seamlessly into your customers' existing networks. Applications � Monitor the power consumption of each sector, unit, workshop... � Manage an electrical installation and optimise your building's power efficiency � Various business, industrial and residential applications PB118059 A9MEM2100 46 Version: 1.0 - 24/01/2020 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS The solution for All markets that can benefit from a solution that includes PowerLogic iEM2100 series meters: � Buildings � Industry � Data Centre & networks � Infrastructures (airport, road tunnels, telecom). Benefits The Acti9 iME kilowatt-hour meters are specially economic and easy to install in all switchboards. Competitive advantages � Compact size � MID compliant (selected models) providing certified accuracy and data security � Four quadrant measurement � Electrical parameter measurement eg. V, I, P, PF � Onboard Modbus or M-bus communication � A complete range of energy meters � Compatible with Acti9 range Energy management system: To get the most effective use from your Schneider Electric measurement and metering devices, we offer a range of dedicated data loggers and gateways for your building energy management. Conformity of standards � IEC 62052-11 � IEC 62053-21 � IEC 62053-23 � EN 50470-1 � EN 50470-3 iEM2100 feature selection iEM2100 Self-powered Display Width (mm) Current input Active Energy accuracy Reactive Energy accuracy Four quadrant Energy measurement Multi-tariff n n 36 63 A Class 1 Class 2 Digital inputs Digital outputs Communication protocol MID for billing application Commercial reference number A9MEM2100 iEM2105 n n 36 63 A Class 1 Class 2 1 P/O A9MEM2105 iEM2110 n n 36 63 A Class 1 Class 2 iEM2135 n n 36 63 A Class 1 Class 2 IEM2150 n n 36 63 A Class 1 Class 2 iEM2155 n n 36 63 A Class 1 Class 2 n n n n 2 1 (tariff switching) 2 1 (tariff switching) 2 P/O's n A9MEM2110 M-bus n A9MEM2135 Modbus RS-485 A9MEM2150 2 1 (tariff switching) Modbus RS-485 n A9MEM2155 Version: 1.0 - 24/01/2020 47 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Acti9 iEM2100 series technical specifications Technical specifications iEM2100 iEM2105 Direct connection 63 A 63 A Pulse output operation 1 pulse/kwh (200ms long) Display capacity 99999 KWh or 999.99 MWh Voltage range (L-N) Operating frequency Meter constant LED Wiring capacity (Top) Wiring capacity (Bottom) Consumption 184 to 276 V AC 6 mm2 2.5 VA IP protection Temperature Active energy n n Reactive energy Active power Reactive power Power Factor Current and voltage Frequency iEM2110 63 A 1 to 1000 pulses / kwh or kvarh (30 to 100ms long) iEM2135 63 A IEM2150 63 A 999999.99KWh 92 to 276 V AC 50/60 Hz 1000 flashes per KWh 4 mm2 32 mm2 (16 mm2 iEM2100/iEM2105) 3 VA IP40 front panel and IP20 casing -25�C to 55�C n n n n n n n n n n n n n n n n n n n n n iEM2155 63 A n n n n n n n DB103483 PB115003 iEM2100/iEM2105 dimensions iEM2110/iEM2135/iEM2150/iEM2155 dimensions See the appropriate product Installation Guide for complete instructions. 48 Version: 1.0 - 24/01/2020 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS iEM2000 and iEM2100 series commercial reference numbers Comm. reference number Product A9MEM2000T A9MEM2000 A9MEM2010 A9MEM2100 A9MEM2050 A9MEM2055 A9MEM2105 A9MEM2110 A9MEM2135 A9MEM2150 A9MEM2155 iEM2000T basic energy meter, no display iEM2000 basic energy meter iEM2010 energy meter, kWh pulse output iEM2100 basic energy meter iEM2050 modular single phase power meter 230 V - 45 A with Modbus iEM2055 modular single phase power meter 230 V - 45 A with Modbus, MID iEM2105 energy meter, kWh pulse output with partial meter iEM2110 energy meter, kWh and kvarh pulse outputs with two tariffs, four quadrant energy measurement, MID certified iEM2135 energy meter, M-Bus communication, four quadrant energy measurement, two tariffs, MID certified iEM2150 energy meter, Modbus communication, four quadrant energy measurement iEM2155 energy meter, Modbus communication, four quadrant energy measurement, two tariffs, MID certified See your Schneider Electric representative for complete ordering information. Version: 1.0 - 24/01/2020 49 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Acti9 iEM3000 Series The Acti9 iEM3000 series energy meters is a cost-attractive, feature-rich energy metering offer for DIN rail, modular enclosures. With Modbus, BACnet, M-bus and LON protocol support, you can easily integrate these meters into commercial and non-critical buildings to add simple energy management applications to any BMS, AMR or EMS system. Applications Cost management applications � Bill checking to verify that you are only charged for the energy you use � Sub-billing individual tenants for their energy consumption, including WAGES � Aggregation of energy consumption, including WAGES, and allocating costs per area, per usage, per shift, or per time within the same facility Network management applications � Basic metering of electrical parameters to better understand the behaviour of your electrical distribution system PB108418 A9MEM3100 50 Version: 1.0 - 24/01/2020 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS More than just kWh meters, the Acti9 iEM3000 series meters provide a full view of both energy consumption and on-site generation with full four-quadrant measurement of active and reactive energy delivered and received. Additionally, extensive real-time measurements (V, I, P, PF) give customers greater detail on their energy usage, and multiple tariffs give customers the flexibility to match the billing structure of their utility. The solution for All markets that can benefit from a solution that includes PowerLogic iEM3000 series meters: � Buildings & industry � Data centres and networks � Infrastructure (airports, road tunnels, telecom) Benefits Optimise your energy consumption & enable energy efficiency practices � Collect and analyse energy consumption data from each area for each type of load or circuit � Gain an accurate understanding of business expenses by allocating the energy-related costs � Use information to implement actions designed to reduce energy consumption Monitor the energy consumption of your tenants or customers and establish accurate invoices � Drive energy-efficient behaviour � Allow building owners to bill tenants for individual measured utility usage � Give accurate and achievable objectives for energy savings Competitive advantages � Compact size � MID compliant (selected models) providing certified accuracy and data security � Programmable digital inputs/ouputs � Multi-tariff capability � Onboard Modbus, LON, M-bus or BACnet communication � A complete range of energy meters � Compatible with Acti9 range Energy management system: To get the most effective use from your Schneider Electric measurement and metering devices, we offer a range of dedicated data loggers and gateways for your building energy management. Conformity of standards � IEC 61557-12 � EN 50470-3 � IEC 62053- � EN 50470-1 21/22 � IEC 61036 � IEC 62053-23 � IEC 61010 Version: 1.0 - 24/01/2020 51 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Acti9 iEM3000 Series iEM3000 feature selection iEM3100 iEM3200 iEM3300 Self-powered n iEM3110 iEM3210 iEM3310 n iEM3115 iEM3215 n iEM3150 iEM3250 iEM3350 n iEM3135 iEM3235 iEM3335 n iEM3155 iEM3255 iEM3355 n iEM3165 iEM3265 iEM3365 n iEM3175 iEM3275 iEM3375 n Width (18mm module) 5/5/7 5/5/7 5/5 5/5/7 5/5/7 5/5/7 5/5/7 5/5/7 Direct measurement (up to) Measurement input through CTs (1A, 5A) Measurement input through VTs 63 A/-/125 A 63 A/-/125 A - / n / - - / n / - 63 A/- / n 63 A/-/125 A 63 A/-/125 A 63 A/-/125 A 63 A/-/125 A 63 A/-/125 A - / n / - - / n / - - / n / - - / n / - - / n / - - / n / - - / n / - - / n / - - / n / - - / n / - Active Energy measurements class 1/0.5S/1 1/0.5S/1 1/0.5S 1/0.5S/1 1/0.5S/1 1/0.5S/1 1/0.5S/1 1/0.5S/1 Four Quadrant Energy measurement Electrical parameter measurements (I, V, P,...) Multi-tariff (internal clock) n n n n n n n n n 4 4 4 4 4 Multi-tariff (external control) 4 2 2 2 2 Measurement display (no. of line) 3 3 3 3 3 3 3 3 Digital inputs Programmable (Tariff control or WAGES input) Tariff control only 1 1 1 1 2 Digital outputs Programmable (Kwh pulse or KW overload alarm) Kwh pulse only 1 1 1 1 M-bus n Communication protocols Modbus BACnet n n n Lon n MID (legal metrology certification) n n n n n n A9MEM3100 A9MEM3110 A9MEM3115 A9MEM3150 A9MEM3135 A9MEM3155 A9MEM3165 A9MEM3175 Commercial reference numbers A9MEM3200 A9MEM3210 A9MEM3215 A9MEM3250 A9MEM3235 A9MEM3255 A9MEM3265 A9MEM3275 A9MEM3300 A9MEM3310 A9MEM3350 A9MEM3335 A9MEM3355 A9MEM3365 A9MEM3375 See your Schneider Electric representative for complete ordering information. How to read table: If a cell contains a single value, that value applies to all meter models identified in the header cell(s). For cells with multiple values, the values correspond from left to right with the meter models listed from top to bottom for each associated header cell. For example, a cell with "A / B / C" means A for iEM31xx models, B for iEM32xx models, and C for iEM33xx models 52 Version: 1.0 - 24/01/2020 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Acti9 iEM3000 Series EM3400/iEM3500 technical specifications iEM3455 Max current 0.333V-1.0V LVCTs Meter constant LED Pulse output frequency Multi-tariff Communication Modbus DI/DO Network Wiring capacity Display max Voltage (L-L) IP protection Temperature Product size Overvoltage & measurement kWh kVARh Active power Reactive power Currents & voltages Overload alarm Hour counter iEM3465 iEM33555 0.333V-1.0V LVCTs Rogowski coils 5000/kWh Up to 500p/kWh 4 tariffs BACnet Modbus 1/1 1P+N, 3P, 3P+N support LVCTs, Rogowski coils, and VTs 6 mm� for currents and 4 mm� for voltages LCD 99999999.9kWh or 99999999.9MWh 3 x 100/173 V AC to 3 x 277/480 V AC (50/60 Hz) IP40 front panel and IP20 casing -25�C to 70�C (K55) 5 steps of 18 mm Category III, Degree of pollution 2 n n n n n n n iEM3565 Rogowski coils BACnet See your Schneider Electric representative for complete ordering information. Version: 1.0 - 24/01/2020 53 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Acti9 iEM3100/iEM3300 series technical specifications Technical specifications iEM3100 iEM3300 iEM3110 iEM3310 iEM3115 iEM3150 iEM3350 iEM3135 iEM3335 iEM3155 iEM3355 iEM3165 iEM3365 Max current (direct connection) 63 A for iEM3100 models, 125 A for iEM3300 models Meter constant LED Pulse output Multi-tariff Up to 1000 p/kWh 4 tariffs 500/kWh Up to 1000 p/kWh 4 tariffs Up to 1000 p/kWh 4 tariffs Communication Modbus Modbus Modbus BACnet DI/DO MID (EN50470-3) 0/1 2/0 n 1/1 1/1 1/1 n n n Network 1P+N, 3P, 3P+N Accuracy class Class 1 (IEC 62053-21 and IEC 61557-12) Class B (EN 50470-3) Wiring capacity 16 mm� for iEM3100 models, 50 mm2 for iEM3300 models Display max. LCD 99999999.9kWh Voltage (L-L) 3 x 100/173 V AC to 3 x 277/480 V AC (50/60 Hz) IP protection IP40 front panel and IP20 casing Temperature -25�C to 55�C (K55) Product size 5 x 18 mm for iEM3100 models, 7 x 18 mm for iEM3300 models Overvoltage and measurement Category III, Degree of pollution 2 kWh n n n n n n n kVARh n n n Active power n n n n Reactive power n n n Currents and voltages n n n n Overload alarm n n n Hour counter n n n iEM3175 iEM3375 LON 1/0 n n n n n n n n 54 Version: 1.0 - 24/01/2020 PLSED309005EN_04 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS Acti9 IEM3200 series technical specifications Technical specifications Max current (1A/5A CT connected) Meter constant LED Pulse output frequency Multi-tariff iEM3200 iEM3210 Up to 500p/kWh iEM3215 4 tariff iEM3250 iEM3235 6 A 5000/kWh Up to 500p/kWh 4 tariffs iEM3255 iEM3265 Up to 500p/kWh 4 tariffs Communication Modbus Modbus Modbus BACnet DI/DO 0/1 2/0 1/1 1/1 1/1 MID (EN50470-3)(1) Network Accuracy class n n n n n 1P+N, 3P, 3P+N support CTs 1P+N, 3P, 3P+N support CTs &VTs (1) Class 0.5S (IEC 62053-22 and IEC61557-12) Class C (EN50470-3) Wiring capacity 6 mm� for currents and 4 mm� for voltages Display max. LCD 99999999.9kWh or 99999999.9MWh Voltage (L-L) 3 x 100/173 V AC to 3 x 277/480 V AC (50/60 Hz) IP protection IP40 front panel and IP20 casing Temperature -25�C to 55�C (K55) Product size 5 steps of 18 mm Overvoltage & measurement Category III, Degree of pollution 2 kWh n n n n n n n kVARh n n n Active power n n n n Reactive power n n n Currents and voltages n n n n Overload alarm n n n Hour counter n n n iEM3275 LON 1/0 n n n n n n n n (1) If used for MID purposes, iEM32xx must use CT secondary set to 5 A. Version: 1.0 - 24/01/2020 55 PLSED309005EN_04 PB105302 BASIC ENERGY METERING iEM3000/iEM3200 series dimensions DIMENSIONS AND CONNECTION PB105303 PB105313 PB105306 Acti9 iEM3100/iEM3200 Series front flaps open and closed Acti9 iEM3000 Series parts 1. Digital inputs for tariff control (iEM3115 / iEM3215) 2. Display for measurement and configuration 3. Pulse out for remote transfer (iEM3110 / iEM3210) 4. Cancellation 5. Confirmation 6. Selection 7. Flashing yellow meter indicator to check accuracy 8. Green indicator: on/off, error iEM3300 series dimensions PB105305 PB1053241 PB113599_m PB113598_m Acti9 iEM3000 Series parts 1. Digital inputs for tariff control (iEM3115 / iEM3215) 2. Display for measurement and configuration 3. Pulse out for remote transfer (iEM3110 / iEM3210) 4. Cancellation 5. Confirmation 6. Selection 7. Flashing yellow meter indicator to check accuracy 8. Green indicator: on/off, error Please see the appropriate Installation Guide for accurate and complete information on the installation of this product. 56 Version: 1.0 - 24/01/2020 PLSED309005EN_04 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS Basic multifunction metering A range of meters designed for cost management and simple network management. Affordable to buy and easy to choose, the highly-capable PowerLogic PM5000 series meters are designed to provide the best combination of features to match all your energy cost management needs. As well as pin-point energy savings, optimal equipment efficiency and utilisation, basic multi-function meters perform a high level assessment of the power quality in an electrical network. � � PowerLogic ION6200 � � PowerLogic PM3000 � � PowerLogic PM5350 � � PowerLogic PM5000 PE86127 PB108447 PB117510 PB111770 M6200 Version: 1.0 - 24/01/2020 PLSED309005EN_05 A9MEM2000 A9MEM2000 A9MEM2000 57 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS ION6200 series The PowerLogic ION6200 is a multi-function, cost-attractive, feature-rich flush or DIN rail-mounted multifunction meter that offers all the measurement capabilities required to monitor an electrical installation. Complete with four-quadrant power, demand, energy, power factor, and frequency measurements, this versatile unit is easy to wire and mount. It offers an excellent upgrade path that lets you start with a low-cost base model and add enhanced functionality over the long term. Applications Cost management applications � Basic metering � Class 0.5S metering and sub-metering � Replace multiple analog meters � Cost allocation � Substation monitoring PE86127 M6200 58 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS The solution for All markets that can benefit from a solution that includes PowerLogic ION6200 series meters: � Buildings � Industry � Data centres and networks � Infrastructure (e.g. airports, road tunnels, telecom) Benefits Optimise your energy consumption & enable energy efficiency practices � Collect and analyse energy consumption data from each area for each type of load or circuit � Gain an accurate understanding of business expenses by allocating the energy-related costs � Identify savings opportunities � Use information to implement actions designed to reduce energy consumption Competitive advantages Connectivity advantages � High visibility front display panel � Megawatt option for all power and energy values � Complete communications - optional RS-485 port, standard Modbus RTU, data rates 1200-19200 baud � Modular construction allows for easy retrofit and planned upgrades � Fast, easy setup via display or software � IEC 60687 Class 0.5s accuracy for tariff metering � Certified for revenue metering � Multiple installation options - direct 4-wire Wye, 3-wire Wye, 3-wire Delta, Direct Delta, and single phase Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � EN 61000-4-2 � EN 61000-4-3 � EN 61000-4-4 � EN 61000-4-5 � EN 61000-4-6 � EN 61010-1 � IEC 61010-1 � IEC 61000-4-2 � IEC 61000-4-3 � IEC 61000-4-4 � IEC 61000-4-5 � IEC 61000-4-6 � IEC 61000-6-2 Version: 1.0 - 24/01/2020 59 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING ION6200 ION6200 feature selection Performance standard IEC61557-12 PMD/Sx/K55/0.5 General Use on LV and HV systems Current and voltage accuracy Energy and power accuracy Number of samples per cycle Instantaneous rms values Current and voltage Frequency Active, power Reactive and apparent power Power factor Energy value Active energy Reactive, apparent energy Demand value Current Active power Reactive and apparent power Power quality measurements Harmonic distortion Display and I/O LED display Pulse output Direct voltage connection (V AC) Communication RS-485 port ION compatibility Modbus RTU protocol Total Per phase Total Per phase Total Per phase Present and max Present Max Present and max Current, voltage See your Schneider Electric representative for complete ordering information. 60 FUNCTIONS AND CHARACTERISTICS ION6200 Standard n n 0.3% 0.5% 64 n n n 400/690 n n n ION6200 EP1 n n 0.3% 0.5% 64 n n n n n n n n n 400/690 n n n ION6200 EP2 n n 0.3% 0.5% 64 n n n n n n n n n n n n n n n n n 400/690 n n n Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS ION6200 ION6200 feature selection Electrical characteristics Type of measurement Measurement accuracy Input-voltage characteristics Input-current characteristics Power supply Inputs/outputs Mechanical characteristics Weight IP degree of protection (IEC 60529) Dimensions Environmental conditions Operating temperature Storage temperature Humidity rating Pollution degree Installation category True rms electrical parameters Up to 64 samples per cycle Current 5 % of full scale 0.3 % reading <5 % of full scale 0.3 % reading + 0.5 % full scale I4 derivation 0.6 % reading + 0.5 % full scale Voltage L-N 0.3 % reading, L-L 0.5 % reading Power IEC 60687 Class 0.5, ANSI 12.20 Class 0.5 Frequency 0.1 % reading Power factor 1.0 % reading Energy IEC 60687 Class 0.5, ANSI 12.20 Class 0.5 Harmonic distortion Total harmonic distortion + 1.0 % Measurement range 60-400 L-N (103.5-690 L-L) V AC RMS (3 phase) 60-400 L-N V AC (single phase) Impedance 2 MW /phase Inputs V1, V2, V3, Vref Overload 1500 V AC RMS continuous Dielectric withstand >3250 V AC RMS; 60 Hz for 1 minute Rated inputs Permissible overload Starting current Burden Inputs Dielectric withstand AC DC Digital outputs RS-485 port 5 A nominal /10 A full scale RMS (+20% overrange with full accuracy, 300 V RMS to ground) 120 A RMS for 1 second, non-recurring 0.005 A RMS 0.05 VA (typical) @ 5 A RMS I1, I2, I3 3000 V RMS for 1 minute Standard: 100-240 V AC, 50-60 Hz Standard: 110-300 V DC, Low Voltage DC: 20-60 V DC 2 optically isolated digital outputs for KY pulsing or control Max forward current: 150 mA Max voltage: 200 V Max current: 150 mA Optically isolated 0.68 kg Meter with display: front IP 65, back IP 30; Transducer unit (no integrated display): IP 30 Remote display unit: front IP 65; back IP 30 Basic unit installed depth: 106.7x106.7x40.6 mm Remote display: 106.7x106.7x22.9 mm -20� C to 70� C ambient air -40� C to 85� C 5 % to 95 % non-condensing 2 III (Distribution) Electromagnetic compatibilty industrial environments Version: 1.0 - 24/01/2020 61 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS ION6200 ION6200 feature selection Electromagnetic compatibility Electrostatic discharge Immunity to radiated fields Immunity to fast transients Surge immunity Conducted immunity Electromagnetic compatibilty for industrial environments Safety Standards Communications IEC 61000-4-2 (EN61000-4-2/IEC801-2) IEC 61000-4-3 (EN61000-4-3/IEC801-3) IEC 61000-4-4 (EN61000-4-4/IEC801-4) IEC 61000-4-5 (EN61000-4-5/IEC801-5) IEC 61000-4-6 (EN61000-4-6/IEC801-6) IEC 61000-6-2 cUL compliant to CSA C22.2 No. 1010-1 IEC1010-1 (EN61010-1) UL 3111-1 RS-485 port Up to 19 200 bps, Modbus RTU, ION compatible protocol Display 19 mm high digits Displays all basic power parameters Bright LED display Easy setup for common configuration parameters Password protection on setup parameters Password protection for demand reset Megawatt options MegaWatt option on meter base with integrated display. Not available for RMICAN or RMICAN-sealed meters MO MegaWatt option on Transducer model with DIN rail mount, Remote Display and 4.2 m cable (RJ11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL. MegaWatt option on Transducer model with DIN rail mount, Remote Display and 2 m cable (RJ11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL. MegaWatt option on Transducer model with DIN rail mount, Remote Display and 9 m cable (RJ11, 6 conductor, 26 gauge). Not available with Security options RMICAN or RMICAN-SEAL. Options card 1 Standard Measurements 2 Enhanced Package #1 3 Enhanced Package #2 4 Standard Measurements, two pulse outputs 5 Enhanced Package #1, two pulse outputs 6 Enhanced Package #2, two pulse outputs 7 Standard Measurements, RS-485 8 Enhanced Package #1, RS-485 9 Enhanced Package #2, RS-485 10 Standard Measurements, two pulse outputs, RS-485 11 Enhanced Package #1, two pulse outputs, RS-485 12 Enhanced Package #2, two pulse outputs, RS-485 N1 N2 N3 Z0A0N Z0A0P Z0A0R Z0B0N Z0B0P Z0B0R A0A0N A0A0P A0A0R A0B0N A0B0P A0B0R Remote modular display (RMD) Model Display type Cable length Standard display For use with Transducer meter base with MegaWatt option No Cable 4.2 m cable connecting RMD to Transducer meter base 2 m cable connecting RMD to Transducer meter base 9 m cable connecting RMD to Transducer meter base M620D R N 0 1 2 3 62 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS ION6200 feature selection Part numbers Part Code 1 Model M6200 A0 R1 2 Form factor R2 Description A Integrated display model Transducer model with DIN rail mount, Remote Display and 4.2 m cable (RJ11, 6 conductor, 26 gauge) Transducer model with DIN rail mount, Remote Display and 2 m cable (RJ11, 6 conductor, 26 gauge) 3 Current inputs 4 Voltage inputs 5 Power supply 6 System frequency 7 Communications 8 I/O 9 Security 10 Measurement package Power supply R3 T1 A 0 A B 0 Z0 A0 A B 0 2 3 4 N P R P620PB P620PC Transducer model DIN rail mount, Remote Display and 9 m cable (RJ11, 6 conductor, 26 gauge) Transducer model with DIN rail mount (requires Comms or pulse outputs) 10 Amp current inputs (12 A max) Autoranging (57-400 V AC L-N / 99-690 V AC L-L) AC Standard: 100-240 V AC, 50-60 Hz DC Standard: 110-300 V DC, Low Voltage DC: 20-60 V DC Calibrated for use with 50 Hz or 60 Hz systems No communications Single RS-485 port (supports Modbus RTU protocol and ION-compatible PML protocol) No I/O This option activates the two Form A digital outputs for kWh, kvarh energy pulsing No hardware lock (setup is password protected) RMANSI: Revenue Meter approved for use in the United States (ANSI C12.16 approved; meets ANSI C12.20 class 0.5 accuracy at 23� C; 10 A current inputs only) RMICAN: Measurement Canada approved revenue meter for use in Canada (10A current inputs only) RMICAN-SEAL: Factory-sealed and Measurement Canada approved revenue meter Standard Measurements (Volts/Amps per phase and avg) Enhanced Package #1 (Standard Measurements plus Energy/Power total, Frequency, Power Factor total, Neutral Current Enhanced Package #2 (all measurements) Standard plug-in power supply (100-240 V AC / 50-60 Hz or 110-300 V DC) Low voltage DC plug-in power supply (20-60 V DC) Version: 1.0 - 24/01/2020 63 PLSED309005EN_05 PE86084 PE86085 BASIC MULTI-FUNCTION METERING ION6200 integrated model dimensions ION6200 TRAN model dimensions ION6200 RMD dimensions PE86090 PE86089 DIMENSIONS AND CONNECTION Mounting integrated model - ANSI 4" (4 1/2" Switchboard) 101.6 mm diameter 85.7 mm 4.67 mm diameter screw & washer 85.7 mm mounting surface Mounting integrated model - DIN 96 screws fit in corners; holes not required 92 mm x 92 mm Mounting the TRAN model RMD port faces up PE86086 PE86087 PE86091 PE86088 PE86085 64 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM3000 series The PowerLogic PM3000 series power meters are a cost-attractive, feature-rich range of DIN railmounted power meters that offers all the measurement capabilities required to monitor an electrical installation. Ideal for power metering and network monitoring applications that seek to improve the availability and reliability of your electrical distribution system, the meters are also fully capable of supporting sub-metering and cost allocation applications. Applications Cost management applications � Bill checking to verify that you are only charged for the energy you use � Aggregation of energy consumption, including WAGES, and cost allocation per area, per usage, per shift or per time within the same facility � Energy cost and usage analysis per zone, per usage or per time period to optimise energy usage Network management applications � Metering of electrical parameters to better understand the behaviour of your electrical distribution system PB108447 Version: 1.0 - 24/01/2020 PLSED309005EN_05 METSEPM3250 65 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS The solution for All markets that can benefit from a solution that includes PowerLogic PM3000 series meters: � Buildings � Industry � Data centres and networks � Infrastructure (e.g. airports, road tunnels, telecom) Benefits Optimise your energy consumption & enable energy efficiency practices � Collect and analyse energy consumption data from each area for each type of load or circuit � Gain an accurate understanding of business expenses by allocating the energy-related costs � Identify savings opportunities � Use information to implement actions designed to reduce energy consumption Competitive advantages Connectivity advantages � Programmable digital input �� External tariff control signal (4 tariff) �� Remote reset partial counter �� External status like breaker status �� Collect WAGES pulses � Programmable digital output �� Alarm (PM3255) �� KWh pulses � Graphic LCD display � Modbus RS-485 with screw terminals Multi-tariff capability The PM3000 series allows users to arrange KWh consumption in four different registers. This can be controlled by: � Digital inputs. Signal can be provided by PLC or utilities � Internal clock programmable by HMI � Through communication This function allows users to: � Make tenant metering for dual source applications to differentiate backup source or utility source � Understand well the consumption during peak time and offpeak time, weekdays and weekends, holiday and working days etc. � Follow up feeders consumption in line with utility tariff rates Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC 61557-12 � IEC 61326-1 � IEC 62052-11 � IEC 62053-21 � IEC 62053-22 � IEC 62053-23 � EN 50470-1 � EN 50470-3 � IEC 61010-1 � EN 55022 66 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM3000 series PM3000 series feature selection Performance standard IEC61557-12 PMD/Sx/K55/0.5 General Use on LV and HV systems Number of samples per cycle CT input 1A/5A VT input Multi-tariff Multi-lingual backlit display Instantaneous rms values Current, voltage Per phase and average Active, reactive, apparent power Total and per phase Power factor Total and per phase Energy values Active, reactive and apparent energy; import and export Demand value PM3200 n n 32 n n 4 n n n n n Current, power (active, reactive, apparent) demand; present n Current, power (active, reactive, apparent) demand; peak Power quality measurements THD Current and voltage Data recording Min/max of the instantaneous values Power demand logs Energy consumption log (day, week, month) Alarms with timestamping Digital inputs/digital outputs Communication RS-485 port Modbus protocol Commercial reference number n METSEPM3200 See your Schneider Electric representative for complete ordering information. PM3210 n n 32 n n 4 n n n n n n n n n 5 0/1 METSEPM3210 PM3250 n n 32 n n 4 n n n n n n n n n 5 n n METSEPM3250 PM3255 n n 32 n n 4 n n n n n n n n n n n 15 2/2 n n METSEPM3255 Version: 1.0 - 24/01/2020 67 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM3000 series PM3000 technical specifications Type of measurement Measurement accuracy Current with x/5A CTs Current with x/1A CTs Voltage Power factor Active/Apparent Power with x/5A CTs Active/Apparent Power with x/1A CTs Reactive power Frequency Active energy with x/5A CTs Active energy with x/1A CTs Reactive energy Data update rate Update rate Input-voltage characteristics Measured voltage Frequency range Input-current characteristics CT primary True rms up to the 15th harmonic on three-phase (3P,3P+N) and single-phase AC systems. 32 samples per cycle 0.3 % from 0.5 A to 6 A 0.5 % from 0.1 A to 1.2 A 0.3 % from 50 V to 330 V (Ph-N), from 80 V to 570 V (Ph-Ph) �0.005 from 0.5 A to 6 A with x/5 A CTs; from 0.1A to 1.2 A with x/1 A CTs and from 0.5 L to 0.8 C Class 0.5 Class 1 Class 2 0.05 % from 45 to 65 Hz IEC 62053-22 Class 0.5s IEC 62053-21 Class 1 IEC 62053-23 Class 2 1s 50 V to 330 V AC (direct / VT secondary Ph-N) 80 V to 570 V AC (direct / VT secondary Ph-Ph) up to 1 MV AC (with external VT) 45 Hz to 65 Hz Adjustable from 1 A to 32767 A CT secondary Measurement input range with x/5A CTs Measurement input range with x/1A CTs Permissible overload Control Power AC DC Input Digital inputs (PM3255) Output Digital output (PM3210) Digital outputs (PM3255) 1 A or 5 A 0.05 A to 6 A 0.02 A to 1.2 A 10 A continuous, 20 A for 10s/hour 100/173 to 277/480 V AC (+/-20%), 3 W/5 VA; 45 Hz to 65 Hz 100 to 300 V DC, 3 W 11 to 40 V DC, 24 V DC nominal, <=4mA maximum burden, 3.5kVrms insulation Optocoupler, polarity sensitive, 5 to 30 V, 15 mA max, 3.5kVrms insulation Solid state relay, polarity insensitive, 5 to 40 V, 50 mA max, 50 max, 3.5kVrms insulation 68 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM3000 series PM3000 technical specifications Mechanical characteristics Weight IP degree of protection (IEC 60529) Dimension Environmental conditions Operating temperature Storage temperature Humidity rating Pollution degree Metering category Dielectric withstand Altitude Electromagnetic compatibility Electrostatic discharge Immunity to radiated fields Immunity to fast transients Immunity to surge Conducted immunity Immunity to power frequency magnetic fields Conducted and radiated emissions Safety Communication RS-485 port Display characteristics Dimensions (VA) Display resolution Standard compliance g Protected throughout by double insulation 0.26 kg IP40 front panel, IP20 meter body 90 x 95 x 70 mm -25 �C to 55 �C -40 �C to 85 �C 5 to 95% RH at 50 �C (non-condensing) 2 III, for distribution systems up to 277/480 V AC As per IEC61010-1, Doubled insulated front panel display 3000 m max Level IV (IEC 61000-4-2) Level III (IEC 61000-4-3) Level IV (IEC 61000-4-4) Level IV (IEC 61000-4-5) Level III (IEC 61000-4-6) 0.5mT (IEC 61000-4-8) Class B (EN 55022) CE as per IEC 61010-1g Half duplex, from 9600 up to 38400 baud, Modbus RTU (double insulation) 43 mm x 34.6 mm 128 x 96 dots IEC 61557-12, EN 61557-12 IEC 61010-1, UL 61010-1 IEC 62052-11, IEC 62053-21, IEC 62053-22, IEC 62053-23 EN 50470-1, EN 50470-3 Version: 1.0 - 24/01/2020 69 PLSED309005EN_05 PB105440 BASIC MULTI-FUNCTION METERING DIMENSIONS AND CONNECTION PM3200 series front of meter Front of meter parts 1 Control power 2 Display with white backlight 3 Flashing yellow meter indicator (to check accuracy) 4 Pulse output for remote transfer (PM3210) 5 Cancellation 6 Confirmation 7 Up 8 Down PM3200 series dimensions PB105447 PM3200 series easy installation PM3200 top and lower flaps PB105302 PB105446 Please see the appropriate Installation Guide for accurate and complete information on the installation of this product. 70 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5350 series The PowerLogic PM5350 series power meters are the new benchmark in affordable, precision metering. The PowerLogic PM5350 power meter offers all the measurement capabilities required to monitor an electrical installation in a space-efficient, single 96 x 96 mm unit with small depth. DNC certifies for marine applications. Applications � Panel instrumentation. � Cost allocation or energy management � Electrical installation remote monitoring � Sophisticated alarming � Circuit beaker monitoring and control PE86278 Version: 1.0 - 24/01/2020 PLSED309005EN_05 METSEPM5350 71 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic PM5350 series meters: � Buildings � Industry � Healthcare � Data Centre and networks � Infrastructure Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance Competitive advantages � Easy to install and operate � Easy for circuit breaker monitoring and control � Power quality analysis � Load management combined with alarm and timestamping � High performance and accuracy Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC 62053-22 � IEC 61557-12 � IEC 62053-23 � IEC 61010-1 � UL 61010-1 � IEC 61326-1 � FCC part 15 Class A � DNV certified 72 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PE86278 PowerLogic PM5350. Feature selection Commercial reference number METSEPM5350 METSEPM5350P Description PM5350 Power & Energy meter with THD alarming PM5350 Power & Energy Meter with THD, Alarming, Multi-tariff and Individual Harmonics The PowerLogic PM5350 power meter offers all the measurement capabilities required to monitor an electrical installation in a single 96 x 96 mm unit extending only 44 mm behind the mounting surface. With its large display, all three-phases and neutral can be monitored simultaneously. The bright, anti-glare display features large characters and powerful backlighting for easy reading even in extreme lighting conditions and viewing angles. The meter menus are understood by all, with the availability of three languages (English, Chinese, Spanish) included standard in the PM5350. Its compact size and high performance make the PowerLogic PM5350 suitable for many applications. � Applications �� Panel instrumentation. �� Cost allocation or energy management. �� Electrical installation remote monitoring. �� Alarming with under/over, digital status, control power interruption, meter reset, self diagnostic issue. �� Circuit Breaker monitoring and control with relay outputs and whetted digital inputs. �� DNV certified for marine applications. � Main characteristics �� Easy to install �� Mounts using two clips, no tools required. Ultra compact meter with 44 mm depth connectable up to 480 V L-L without voltage transformers for installations compliant with category III, as per IEC 61010-1. See specification table for UL voltage limits. �� Easy to operate �� Intuitive navigation with self-guided, language selectable menus, six lines, four concurrent values. Two LEDs on the meter face help the user confirm normal operation (heartbeat/communications indicator LED: green and other LED orange, customizable either for alarms or energy pulse outputs). �� Easy circuit breaker monitoring and control �� The PM5350 provides two relay outputs (high performance) with capability to command most of the circuit breaker coils directly. In addition, monitored switches can be wired directly to the meter without external power supply. �� System status at a glance �� Bright, anti-glare, backlit display plus two LEDs; orange for energy pulse or alarm and green for heartbeat/communications indication. �� IEC 62053-22 class 0.5S accuracy for active energy �� Accurate energy measurement for cost allocation. �� Power Quality analysis �� The PM5350 offers THD and TDD measurements as standard. Total Demand Distortion is based on a point of common coupling (PCC), which is a common point that each user receives power from the power source. The TDD compares the contribution of harmonics versus the maximum demand load. �� Load management �� Peak demands with timestamping are provided. Predicted demand values can be used in basic load shedding applications. �� Alarming with timestamping �� Over 30 alarm conditions, such as under/over conditions, digital input changes, and phase unbalance inform you of events. A time-stamped log maintains a record of the last 40 alarm events. �� Load timer setpoint adjustable to monitor and advise maintenance requirements. Performance Standard Meets IEC 61557-12 PMD/Sx/K70/0.5. Version: 1.0 - 24/01/2020 73 PLSED309005EN_05 PE86324 PE86323_m BASIC MULTI-FUNCTION METERING PM5350 meter parts A Retainer clips. B Control power supply connector. C Voltage inputs. D Digital outputs. E RS-485 port (COM1). F Digital input. G Optical revenue switch. H Current inputs. 74 FUNCTIONS AND CHARACTERISTICS PM5350 series PM5350 technical specifications General Use on LV and MV systems Basic metering with THD and min/max readings Instantaneous rms values Current Total, Phases and neutral Voltage Total, Ph-Ph and Ph-N Frequency Real, reactive, and apparent power Total and per phase b b b b b Signed True Power Factor Total and per phase Signed, Four Quadrant Displacement PF Total and per phase Signed, Four Quadrant Unbalanced I, VL-N, VL-L b Energy values Stored in non-volatile memory Accumulated Active, Reactive and Apparent Energy Received/Delivered; Net and absolute; b Demand values Current average Present, Last, Predicted, Peak, & Peak Date Time b Active power Present, Last, Predicted, Peak, & Peak Date Time b Reactive power Present, Last, Predicted, Peak, & Peak Date Time b Apparent power Present, Last, Predicted, Peak, & Peak Date Time b Peak demand with timestamping D/T for current & powers b b Demand calculation Sliding, fixed and rolling block, thermal b b Synchronization of the measurement window b b Other measurements I/O timer b b Operating timer b b Active load timer b b Alarm counters b b Power quality measurements THD, thd (Total Harmonic Distortion) TDD, thd (Total Demand Distortion) Data recording Min/max of instantaneous values, plus phase identification I, V L-N, V L-L b b b Alarms with 1s timestamping Standard 29; Unary 4; Digital 4 Alarms stored in non-volatile memory 40 events b Inputs/Outputs Digital inputs Digital outputs Display White backlit LCD display, 6 lines, 4 concurrent values IEC or IEEE visualization mode Communication Modbus RTU, Modbus ASCII, Jbus Protocol Firmware update via RS-485 serial port (DLF3000 via the Schneider Electric website: www.schneider-electric.com) 4 (DI1, DI2, DI3, DI4) 2 relay outputs (DO1, DO2) b b b b Version: 1.0 - 24/01/2020 PLSED309005EN_05 PE86292 BASIC MULTI-FUNCTION METERING Front screen view of PM5350. Version: 1.0 - 24/01/2020 PLSED309005EN_05 FUNCTIONS AND CHARACTERISTICS Electrical characteristics Type of measurement True rms up to the 15th harmonic on three-phase (3P, 3P + N) 32 samples per cycle, zero blind Measurement Current, Phase g accuracy Voltage, L-N g Power Factor g �0.30 % �0.30 % �0.005 Power, Phase IEC 61557-12 Class 0.5; For 5 A nominal CT (for 1 A nominal CT when I > 0.15 A) �0.5 % from 0.25 A to 9.0 A at COS = 1 �0.6 % from 0.50 A to 9.0 A at COS = 0.5 (ind or cap) Frequencyg Real Energy Reactive Energy �0.05 % IEC 62053-22 Class 0.5 S; IEC 61557-12 Class 0.5; For 5 A nominal CT (for 1 A nominal CT when I > 0.15 A) �0.5 % from 0.25 A to 9.0 A at COS = 1 �0.6 % from 0.50 A to 9.0 A at COS = 0.5 (ind or cap) IEC 61557-12 Class 0.5 IEC 62053-23 Class 3, IEC 61557-12 Class 2 For 5 A nominal CT (for 1 A nominal CT when I > 0.15 A) �2.0 % from 0.25 A to 9.0 A at SIN = 1 �2.5 % from 0.50 A to 9.0 A at SIN = 0.5 (ind or cap) Data update rate 1 second nominal (50/60 cycles) Input-voltage VT primary 1.0 MV AC max, starting voltage depends on VT ratio. U nom 277 V L-N Measured voltage with IEC: 20 to 480 V AC L-L; 20 to 277 V AC L-N, CAT III overrange & Crest IEC: 20 to 690 V AC L-L; 20 to 400 V AC L-N, CAT II Factor UL: 20 to 300 V AC L-L, CAT III Permanent overload 700 V AC L-L, 404 V AC L-N Impedance 10 MW Frequency range 45 to 70 Hz Input-current CT ratings Secondary 1A, 5 A nominal Measured voltage with 5 mA to 9 A overrange & crest factor Withstand Continuous 20 A,10 sec/hr 50 A,1 sec/hr 500 A Impedance < 0.3 mW Frequency range 45 to 70 Hz Burden < 0.024 VA at 9 A AC control power Operating range Burden 85 - 265 V AC 4.1 VA / 1.5 W typical, 6.7 VA / 2.7 W max at 120 V AC 6.3 VA / 2.0 W typical, 8.6 VA / 2.9 W max at 230 V AC 9.6 VA / 3.5 W maximum at 265 V AC Frequency Ride-through time DC control power Operating range Burden Ride-through time 45 to 65 Hz 100 mS typical at 120 V AC and maximum burden 400 mS typical at 230 V AC and maximum burden 100 to 300 V DC 1.4 W typical, 2.6 W maximum at 125 V DC 1.8 W typical, 2.7 W maximum at 250 V DC 3.2 W maximum at 300 V DC 50 mS typical at 125 V DC and maximum burden Real time clock Ride-through time Digital output Number/Type 30 seconds 2 - Mechanical Relays Output frequency 0.5 Hz maximum (1 second ON / 1 second OFF minimum times) Switching Current 250 V AC at 2.0 Amps, 200 k cycles, resistive 250 V AC at 8.0 Amps, 25 k cycles, resistive 250 V AC at 2.0 Amps, 100 k cycles, COS =0.4 250 V AC at 6.0 Amps, 25 k cycles, COS =0.4 30 V DC at 2.0 Amps, 75 k cycles, resistive 30 V DC at 5.0 Amps, 12.5 k cycles, resistive Isolation 2.5 kVrms Status Digital Voltage ratings Inputs Input Resistance ON 18.5 to 36 V DC, OFF 0 to 4 V DC 110 k W Maximum Frequency 2 Hz (T ON min = T OFF min = 250 ms) Response Time 10 ms Isolation 2.5 kVrms Whetting output Nominal voltage Allowable load 24 V DC 4 mA Isolation 2.5 kVrms g Measurements taken from 45 Hz to 65 Hz, 0.5 A to 9 A, 57 V to 347 V & 0.5 ind to 0.5 cap power factor with a sinusoidal wave. 75 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5350 series PM5350 technical specifications Mechanical characteristics Weight IP degree of protection (IEC 60529) Dimensions W x H x D Mounting position Panel thickness Environmental characteristics Operating temperature Meter Display Storage temp. Humidity rating Pollution degree Altitude Meter + display Indoor use only Not suitable for wet locations Electromagnetic compatibility Electrostatic discharge Immunity to radiated fields Immunity to fast transients Immunity to impulse waves Conducted immunity Immunity to magnetic fields Immunity to voltage dips Radiated emissions Conducted emissions Harmonics Flicker emissions Safety Europe U.S. and Canada Measurement category (Voltage and current inputs) Overvoltage Category (Control power) Dielectric 250 g IP51 front display, IP30 meter body (excluding connectors) 96 x 96 x 44 mm (depth of meter from housing mounting flange) 96 x 96 x 13 mm (protrusion of meter from housing flange) Vertical 6.35 mm max -25 �C to 70 �C -20 �C to 70 �C (Display functions to -25 �C with reduced performance) -40 �C to 85 �C 5 % to 95 % RH at 50 �C (non-condensing) 2 3000 m max IEC 61000-4-2g IEC 61000-4-3g IEC 61000-4-4g IEC 61000-4-5g IEC 61000-4-6g IEC 61000-4-8g IEC 61000-4-11g FCC part 15 class A, EN 55011 Class A FCC part 15 class A, EN 55011 Class A IEC 61000-3-2g IEC 61000-3-3g e, as per IEC 61010-1 cULus as per UL 61010-1, IEC 61010-1 (3rd Edition) Per IEC 61010-1: CAT III, 277 V L-N / 480 V L-L nominal; CAT II 400 V L-N / 690 V L-L nominal Per UL 61010-1 and CSA C22.2 No. 61010-1: CAT III, 300 V L-L CAT III As per IEC 61010-1 Double insulated front panel display Protective Class Class II Communication RS-485 port 2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd, None, 1 stop bit if parity Odd or Even, 2 stop bits if None; Modbus RTU, Modbus ASCII (7 or 8 bit), JBUS Firmware and language file update Update via communication port using DLF3000 software Isolation 2.5 kVrms, double insulated Human machine interface Display type Monochrome Graphics LCD Resolution 128 x 128 Backlight White LED Viewable area (W x H) 67 x 62.5 mm Keypad 4-button Indicator Heartbeat / Comm activity Green LED Energy pulse output / Active alarm indication (configurable) Type Optical, amber LED Wavelength 590 to 635 nm Maximum pulse rate 2.5 kHz g As per IEC 61557-12 76 Version: 1.0 - 24/01/2020 PLSED309005EN_05 PE86279 BASIC MULTI-FUNCTION METERING Rear of meter - open DIMENSIONS AND CONNECTION Rear view retainers - installation PE86274 For detailed installation instructions see the product's Installation Guide. Version: 1.0 - 24/01/2020 77 PLSED309005EN_05 PE86275 BASIC MULTI-FUNCTION METERING Rear view retainers - users DIMENSIONS AND CONNECTION For detailed installation instructions see the product's Installation Guide. 78 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5350IB and PM5350PB series The PowerLogic PM5350IB and PM5350PB series power meters are the new benchmark in affordable, precision metering. The PowerLogic PM5350P power meter offers all the measurement capabilities required to monitor an electrical installation in a space-efficient, single 96 x 96 mm unit. Applications � Panel instrumentation. � Cost allocation or energy management � Electrical installation remote monitoring. � Sophisticated alarming � Circuit Breaker monitoring and control PE86278 Version: 1.0 - 24/01/2020 PLSED309005EN_05 METSEPM5350IB 79 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic PM5350IB and PM5350PB series meters: � Buildings � Industry � Healthcare � Data Centre and networks � Infrastructure Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance Competitive advantages � Easy to install and operate � Easy for circuit breaker monitoring and control � Power quality analysis � Load management combined with alarm and timestamping � High performance and accuracy Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC 62053-22 � IEC 61557-12 � IEC 62053-23 � IEC 61326-1 � IEC 61010-1 � UL 61010-1 � IEC 61000-4-2 � IEC 61000-4-3 80 Version: 1.0 - 24/01/2020 PLSED309005EN_05 PE86278 BASIC MULTI-FUNCTION METERING PowerLogic PM5350IB FUNCTIONS AND CHARACTERISTICS The PM5350IB and PM5350PB are compact multi-circuit power meters specially designed to monitor Busway power distribution systems. They provide consumption and alarm data by circuit, for up to three single-phase circuits and can also be installed in different electrical configurations, monitoring 1-, 2-, and 3-phase circuits. These meters are an ideal solution for cost management and sub-billing in data centres. With its large display, all individual circuits can be monitored simultaneously. The bright, anti-glare display features large characters and powerful backlighting for easy reading even in extreme lighting conditions and viewing angles. � Main characteristics �� Easy to install �� Mounts using two clips, no tools required. Ultra compact meter with 44 mm depth connectable up to 480 V L-L without voltage transformers. See specification table for voltage inputs details. �� Easy to operate �� Intuitive navigation with self-guided, language selectable menus, six lines, four concurrent values. �� System status at a glance �� Bright, anti-glare, backlit display plus two LEDs; orange for energy pulse or alarm and green for heartbeat/communications indication. �� IEC 62053-22 class 0.5S accuracy for active energy Accurate energy measurement for cost allocation and sub-billing.g � Circuit breaker monitoring �� Four digital inputs provide an easy way to monitor status, alarm and report on circuit breaker trips. � Multi-level alarming �� Five different alarm levels (high, high-high, low, low-low, tripped) optimized network management and downtime prevention. � Performance Standard Meets IEC 61557-12 PMD/Sx/K70/0.5. gSub-billing might be subject to local regulation. Feature selection Commercial reference number METSEPM5350IB METSEPM5350PB Description PowerLogic PM5350IB PowerLogic PM5350PB Version: 1.0 - 24/01/2020 81 PLSED309005EN_05 PB113624_m BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS Dimensions PM5350IB Dimensions PM5350PB PM5350IB/PB series PM5350IB/PB technical specifications General Use on LV and MV systems Basic metering with THD and min/max readings Instantaneous rms values Current Total, Phases and neutral Voltage Total, Ph-Ph and Ph-N Frequency Real, reactive, and apparent power Total and per phase True Power Factor Total and per phase Displacement PF Total and per phase Unbalanced I, V L-N, V L-L Energy Total and per circuit Accumulated Active, Reactive and Apparent Energyg Received/Delivered; Net and absolute Demand values Current averageg Active powerg Reactive powerg Present, Last, Predicted, Peak, & Peak Date Time Present, Last, Predicted, Peak, & Peak Date Time Present, Last, Predicted, Peak, & Peak Date Time Apparent powerg Present, Last, Predicted, Peak, & Peak Date Time Peak demand with timestampingg Power quality THD, thd (Total Harmonic Distortion) TDD, thd (Total Demand Distortion) Data recording total and per circuit Min/max of instantaneous values, plus circuit identificationg Alarms with 1s timestamping Alarms stored in non-volatile memoryg Inputs/Outputs Digital inputs Digital outputs Display White backlit LCD display, 6 lines, 4 concurrent values IEC or IEEE visualization mode Communication Modbus RTU, Modbus ASCII, Jbus Protocol Firmware update via RS-485 serial port (DLF3000 via the Schneider Electric website: www.schneider-electric.com) 5350IB 5350PB b b b b b Signed Signed, Four Quadrant Signed, Four Quadrant b b b b b b I, V L-N, V L-L b b Standard 29; Unary 4; Digital 4 40 events b 4 (DI1, DI2, DI3, DI4) 2 relay outputs (DO1, DO2) b b b b gStored in non-volatile memory PB113625_m 82 Version: 1.0 - 24/01/2020 PLSED309005EN_05 PE86292 BASIC MULTI-FUNCTION METERING Front screen view of PM5350. Version: 1.0 - 24/01/2020 PLSED309005EN_05 FUNCTIONS AND CHARACTERISTICS Electrical characteristics 5350IB 5350PB Type of measurement True rms up to the 15th harmonic 32 samples per cycle, zero blind Measurement Current, Circuit g accuracy Voltage, L-N g Power Factor g Power, Circuit Frequency g Real Energy Reactive Energy Data update rate �0.30 % �0.30 % �0.005 IEC 61557-12 Class 0.5; For 5 A nominal CT (for 1 A nominal CT when I > 0.15 A) �0.5 % from 0.25 A to 9.0 A at COS = 1 �0.6 % from 0.50 A to 9.0 A at COS = 0.5 (ind or cap) �0.05 % IEC 62053-22 Class 0.5 S; IEC 61557-12 Class 0.5; For 5 A nominal CT (for 1 A nominal CT when I > 0.15A) �0.5 % from 0.25 A to 9.0 A at COS = 1 �0.6 % from 0.50 A to 9.0 A at COS = 0.5 (ind or cap)IEC 61557-12 Class 0.5 IEC 62053-23 Class 3, IEC 61557-12 Class 2 For 5 A nominal CT (for 1 A nominal CT when I > 0.15A) �2.0 % from 0.25 A to 9.0 A at SIN = 1 �2.5 % from 0.50 A to 9.0 A at SIN = 0.5 (ind or cap) 1 second nominal (50/60 cycles) Input-voltage VT primary 1.0 MV AC max, starting voltage depends on VT ratio. U nom Measured voltage with overrange & Crest Factor 277 V L-N UL: 20 to 300 V AC L-L UL: 20 to 480 V AC L-L IEC: 20 to 690 V V AC IEC: 20 to 690 V V AC L-L; 20 to 400 V AC L-N L-L; 20 to 400 V AC L-N Permanent overload 700 V AC L-L, 404 V AC L-N Impedance 10 M W Frequency range 45 to 70 Hz Input-current CT ratings Primary Adjustable 1 A to 32767 A Secondary 1 A, 5 A nominal Measured voltage with overrange & Crest Factor 5 mA to 9 A Withstand Continuous 20 A,10 sec/hr 50 A,1 sec/hr 500 A Impedance < 0.3 mW Frequency range 45 to 70 Hz Burden < 0.024 VA at 9 A AC control power Operating range Burden 85 to 277 V AC 4.1 VA / 1.5 W typical, 6.7 VA / 2.7 W max at 120 V AC 6.3 VA / 2.0 W typical, 8.6 VA / 2.9 W max at 230 V AC 9.6 VA / 3.5 W maximum at 265 V AC Frequency Ride-through time 45 to 65 Hz 100 mS typical at 120 V AC and maximum burden 400 mS typical at 230 V AC and maximum burden DC control power Operating range Burden 100 to 300 V DC 1.4 W typical, 2.6 W maximum at 125 V DC 1.8 W typical, 2.7 W maximum at 250 V DC 3.2 W maximum at 300 V DC Ride-through time 50 mS typical at 125 V DC and maximum burden Real time clock Ride-through time Digital output Number/Type 30 seconds 2 - Mechanical Relays Output frequency Switching Current Isolation 0.5 Hz maximum (1 second ON / 1 second OFF minimum times) 250 V AC at 2.0 Amps, 200 k cycles, resistive 250 V AC at 8.0 Amps, 25 k cycles, resistive 250 V AC at 2.0 Amps, 100 k cycles, COS = 0.4 250 V AC at 6.0 Amps, 25 k cycles, COS = 0.4 30 V DC at 2.0 Amps, 75 k cycles, resistive 30 V DC at 5.0 Amps, 12.5 k cycles, resistive 2.5 kVrms Status Digital Voltage ratings Inputs Input Resistance ON 18.5 to 36 V DC, OFF 0 to 4 V DC 110 k W Maximum Frequency 2 Hz (T ON min = T OFF min = 250 ms) Response Time 10 ms Isolation 2.5 kVrms Whetting output Nominal voltage Allowable load 24 V DC 4 mA Isolation 2.5 kVrms g Measurements taken from 45 Hz to 65 Hz, 0.5 A to 9 A, 57 V to 347 V & 0.5 ind to 0.5 cap power factor with a sinusoidal wave. 83 BASIC MULTI-FUNCTION METERING PM5350IB/PB series PM5350IB/PB technical specifications Mechanical characteristics Weight IP degree of protection (IEC 60529) Dimensions W x H x D Mounting position Panel thickness Environmental characteristics (for indoor use only) Operating temperature Meter Display Storage temp. Meter + display Humidity rating Pollution degree Altitude Indoor use only Not suitable for wet locations Electromagnetic compatibility (for indoor use only) Electrostatic discharge Immunity to radiated fields Immunity to fast transients Immunity to impulse waves Conducted immunity Immunity to magnetic fields Immunity to voltage dips Radiated emissions Conducted emissions Harmonics Flicker emissions Safety Europe U.S. and Canada Measurement category (Voltage and current inputs) Overvoltage Category (Control power) Dielectric Protective Class Communication RS-485 port Firmware and language file update Isolation Human machine interface Display type Resolution Backlight Viewable area (W x H) Keypad Indicator Heartbeat / Comm activity Energy pulse output / Active alarm indication (configurable) Type Wavelength Maximum pulse rate g V L-L is limited to 700 V AC (2) As per IEC 61557-12 84 FUNCTIONS AND CHARACTERISTICS 5350IB 5350PB 250 g IP51 front display, IP30 meter body 96 x 96 x 44 mm (depth of meter from housing mounting flange) 96 x 96 x 13 mm (protrusion of meter from housing flange) Vertical 6.35 mm max -25 �C to 70 �C -20 �C to 70 �C (Display functions to -25�C with reduced performance) -40 �C to 85 �C 5 to 95 % RH at 50 �C (non-condensing) 2 3000 m max. IEC 61000-4-2g IEC 61000-4-3g IEC 61000-4-4g IEC 61000-4-5g IEC 61000-4-6g IEC 61000-4-8g IEC 61000-4-11g FCC part 15 class A, EN 55011 Class A FCC part 15 class A, EN 55011 Class A IEC 61000-3-2g IEC 61000-3-3g e, as per IEC 61010-1 cULus as per UL61010-1, IEC 61010-1 (2nd Edition) UL: 20 to 300 V AC L-L, CATIII IEC: 20 to 480V V AC L-L; 20 to 277 V AC L-N, CATIII 20 to 690V V AC L-L; 20 to 400 V AC L-N, CATII UL: 20 to 480 V AC L-L, CATIII IEC: 20 to 480V V AC L-L; 20 to 277 V AC L-N, CATIII 20 to 690V V AC L-L; 20 to 400 V AC L-N, CATII CAT III As per IEC 61010-1 Double insulated front panel display Class II 2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd, None, 1 stop bit if parity Odd or Even, 2 stop bits if None; Modbus RTU, Modbus ASCII (7 or 8 bit), JBUS Update via comunication port using DLF3000 software 2.5 kVrms, double insulated Monochrome Graphics LCD 128 x 128 White LED 67 x 62.5 mm 4-button Green LED Optical, amber LED 590 to 635 nm 2.5 kHz Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING DIMENSIONS AND CONNECTION PM5350IB/PB series Parts of PM5350IB and PM5350PB (rear panel door removed) PB113626 PM5350IB PB113626 Version: 1.0 - 24/01/2020 PLSED309005EN_05 PM5350PB A Control power B Voltage inputs C Current inputs D Digital inputs E Whetting voltage source (for digital inputs) F RS-485 communications G Digital outputs H Retainer clips For detailed installation instructions see the product's Installation guide. 85 BASIC MULTI-FUNCTION METERING PM5350IB/PB series Installation DIMENSIONS AND CONNECTION PM5350IB PM5350PB For detailed installation instructions see the product's Installation Guide. 86 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5350P series The PowerLogic PM5350P series power meters are the new benchmark in affordable, precision metering. The PowerLogic PM5350P power meter offers all the measurement capabilities required to monitor an electrical installation in a space-efficient, single 96 x 96 mm unit. Applications � Panel instrumentation � Cost allocation or energy management � Electrical installation remote monitoring � Sophisticated alarming � Circuit Breaker monitoring and control PB117510 Version: 1.0 - 24/01/2020 PLSED309005EN_05 METSEPM5350P 87 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic PM5350P series meters: � Buildings � Industry � Healthcare � Data Centre and networks � Infrastructure Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance Competitive advantages � Easy to install and operate � Easy for circuit breaker monitoring and control � Power quality analysis � Load management combined with alarm and timestamping � High performance and accuracy � Multi-tariff capabilities � Individual harmonics up to 31st Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC 62053-22 � IEC 61557-12 � IEC 62053-23 � IEC 61010-1 � IEC 61326-1 � UL 61010-1 � IEC 61000-3-3 88 Version: 1.0 - 24/01/2020 PLSED309005EN_05 PB117510 BASIC MULTI-FUNCTION METERING PowerLogic PM5350P Version: 1.0 - 24/01/2020 PLSED309005EN_05 FUNCTIONS AND CHARACTERISTICS The PowerLogic PM5350P power meter offers electrical installation measurement capabilities in a single 96 x 96 mm unit. Three-phases and neutral can be monitored simultaneously using a bright, anti-glare display with large characters and backlighting. Menus are intuitive and the meter supports English, Chinese, Hebrew, and Spanish. Its compact size and high performance make the PowerLogic PM5350P suitable for many applications. � Applications �� Panel instrumentation. �� Cost allocation or energy management. �� Electrical installation remote monitoring. �� Alarming with under/over, digital status, control power interruption, meter reset, self diagnostic issue. �� Circuit Breaker monitoring and control with relay outputs and whetted digital inputs. � Main characteristics �� Easy to install �� Mounts using two clips, no tools required. Ultra compact meter with 44 mm depth connectable up to 480 V L-L without voltage transformers for installations compliant with category III, as per IEC 61010-1. See specification table for UL voltage limits. �� Easy to operate �� Intuitive navigation with self-guided, language selectable menus, six lines, four concurrent values. Two LEDs help confirm normal operation. �� Easy circuit breaker monitoring and control �� Two relay outputs (high performance) to command most circuit breaker coils directly. Monitored switches can be wired directly without external power supply. �� System status at a glance �� Bright, anti-glare, backlit display plus two LEDs; orange for energy pulse or alarm and green for heartbeat/communications indication. �� IEC 62053-22 class 0.5S accuracy for active energy �� Accurate energy measurement for cost allocation. �� Power Quality analysis �� The PM5350P offers THD and TDD measurements as standard. Total Demand Distortion is based on a point of common coupling (PCC), which is a common point that each user receives power from the power source. The TDD compares the contribution of harmonics versus the maximum demand load. In addition, it has individual harmonics (odd) measurement up to 31st harmonics. These types of power quality parameters help to identify the source of harmonics that can harm transformers, capacitors, generators, motors and electronic equipment. � Load management �� Peak demands with Timestamping are provided. Predicted demand values can be used in basic load shedding applications. Alarming with timestamping �� Over 30 alarm conditions, such as under/over conditions, digital input changes, and phase unbalance inform you of events. A time-stamped log maintains a record of the last 40 alarm events. �� Load timer setpoint adjustable to monitor and advise maintenance requirements. �� Performance Standard Meets IEC 61557-12 PMD/Sx/K70/0.5. 89 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PE86323_m PE86324 PM5350P meter parts A Retainer clips. B Control power supply connector. C Voltage inputs. D Digital outputs. E RS-485 port (COM1). F Digital inputs. G Optical revenue switch. H Current inputs. Feature guide PM5350P General Use on LV and MV systems Basic metering with THD and min/max readings Instantaneous rms values Current Total, Phases and neutral Voltage Total, Ph-Ph and Ph-N Frequency Real, reactive, and apparent power Total and per phase b b b b b Signed True Power Factor Total and per phase Signed, Four Quadrant Displacement PF Total and per phase Signed, Four Quadrant Unbalanced I, VL-N, VL-L b Energy values Stored in non-volatile memory Accumulated Active, Reactive and Apparent Energy Received/Delivered; Net and absolute; b Demand values Current average Present, Last, Predicted, Peak, & Peak Date Time b Active power Reactive power Present, Last, Predicted, Peak, & Peak Date Time b Present, Last, Predicted, Peak, & Peak Date Time b Apparent power Present, Last, Predicted, Peak, & Peak Date Time b Multi-tariff 4 tariffs b Peak demand with timestamping D/T for current & powers b b Demand calculation Sliding, fixed and rolling block, thermal b b Synchronization of the measurement window b b Other measurements I/O timer b b Operating timer b b Active load timer b b Alarm counters b b Power quality measurements THD, thd (Total Harmonic Distortion) TDD, thd (Total Demand Distortion) Harmonics Individual (Odd) Data recording I, V L-N, V L-L b 31st Min/max of instantaneous values, plus phase identification b b Alarms with 1s timestamping Standard 29; Unary 4; Digital 4 Alarms stored in non-volatile memory 40 events b Inputs/Outputs Digital inputs Digital outputs Display White backlit LCD display, 6 lines, 4 concurrent values IEC or IEEE visualization mode 4 (DI1, DI2, DI3, DI4) 2 relay outputs (DO1, DO2) b b Communication Modbus RTU, Modbus ASCII, Jbus Protocol b Firmware update via RS-485 serial port (DLF3000 via the Schneider Electric website: b www.schneider-electric.com) 90 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PB117511 PowerLogic PM5350P front display Version: 1.0 - 24/01/2020 PLSED309005EN_05 Electrical characteristics Type of measurement Measurement Active Energy accuracy Reactive Energy Active Power RMS including harmonics upto 31st on three-phase AC system (3P, 3P + N) 64 samples per cycle, zero blind Class 0.5S as per IEC 62053-22 up to 9A Class 0.5 as per IEC 61557-12 up to 9A For 5 A nominal CT (for 1 A nominal CT when I > 0.15 A) Class 2 as per IEC 62053-23 up to 9 A Class 2 as per IEC 61557-12 up to 9 A For 5 A nominal CT (for 1 A nominal CT when I > 0.15 A) Class 0.5 as per IEC 61557-12 upto 9A For 5 A nominal CT (for 1 A nominal CT when I > 0.15 A) Frequencyg Current, Phaseg Voltage, L-Ng Power Factorg Voltage Harmonics Voltage THD/thd Current Harmonics �0.05 % �0.5 % �0.50 % �0.01 Count Class 5 as per 61557-12 g g Class 5 as per 61557-12 g g Class 5 as per 61557-12 g g Current THD/ thd Class 5 as per 61557-12 g g g Measurement applicable from 45 Hz to 65 Hz ,0.5 A to 9 A , 57 V to 347V and 0.5 Inductive , 0.5 capacitive power factor With a sinusoidal wave g g Accuracy applicable up to 15th Harmonics measured up to 31st Harmonics Data update rate 1 second nominal (50/60 cycles) Input voltage U nom 277 V L-N Measured voltage with Per IEC 61010-1 overrange & Crest Factor CAT III, 20-277 V L-N / 20-480 V L-L CAT II, 20-400 V L-N / 20-690 V L-L Per UL 61010-1 and CSA C22.2 NO. 61010-1 CAT III, 20-300 V L-L AC Permanent overload 700 V AC L-L, 404 V AC L-N Impedance 5 MW Frequency range 45 to 65 Hz Input-current CT ratings Secondary 1 A, 5 A nominal Measured voltage with 5 mA to 9 A overrange & Crest Factor Withstand Continuous 20 A,10 sec/hr 50 A,1 sec/hr 500 A Impedance < 0.3 MW Frequency range 45 to 65 Hz Burden < 0.024 V A at 9 A AC control power Operating range Burden 85 - 265 V AC 7 VA / 4W maximum at 120 V AC, 9 VA / 5W maximum at 230 V AC, 11.9 VA /5W maximum at 265 V AC Frequency 45 to 65 Hz Ride-through time 40 mS typical at 120 V AC and maximum burden 250 mS typical at 230 V AC and maximum burden DC control power Operating range Burden 100 to 300 V DC 4 W maximum at 125 V DC, 5 W maximum at 250 V DC, 5 W maximum at 300 V DC Ride-through time 30 mS typical at 125 V DC and maximum burden Real time clock Clock drift Battery Backup time ~0.5 seconds per day 3 years without control power Digital output Number/Type 2 - Mechanical Relays Output frequency Switching Current 0.5 Hz maximum (1 second ON / 1 second OFF minimum times) 250 V AC at 2.0 Amps, 200k cycles, resistive 250 V AC at 8.0 Amps, 25k cycles, resistive 250 V AC at 2.0 Amps, 50k cycles, COS=0.4 30 V DC at 2.0 Amps, 75k cycles, resistive 30 V DC at 5.0 Amps, 12.5k cycles, resistive NOTE: The COS ratings are not evaluated for UL Isolation 2.5 kVrms Status Digital Inputs Voltage ratings Input Resistance Maximum Frequency ON 18.5 to 36 V DC, OFF 0 to 4 V DC 110 k W 2 Hz (T ON min = T OFF min = 250 ms) Whetting output Response Time Isolation Nominal voltage Allowable load Isolation 10 ms 2.5 kVrms 24 V DC 4 mA 2.5 kVrms 91 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PB117512 Rear view of PowerLogic PM5350P Feature selection Commercial reference number Description METSEPM5350 METSEPM5350IB METSEPM5350PB METSEPM5350P METSEPM5100 METSEPM5110 RS-485 Modbus, THD, 4DI, 2Relay RS-485, 4DI/2Relay, Multi-level alarm, UL480V, 4DI/2Relay RS-485, 4DI/2Relay, Multi-level alarm, UL300V, 4DI/2Relay RS-485 Modbus, THD, Multi-tariff and individual harmonics 4DI/2relay No commnication, 1DO RS-485 Modbus, 1DO METSEPM5111 RS-485 ModBus, 1DO, MID certified METSEPM5310 RS-485 Modbus, 2DI/2DO METSEPM5320 METSEPM5330 METSEPM5331 METSEPM5340 METSEPM5341 METSEPM5560 METSEPM5561 METSEPM5562 METSEPM5562MC METSEPM5563 METSEPM5563RD Ethernet 2DI/2DO RS-485 Modbus, 2DI/2DO, 2Relay RS-485 Modbus, 2DI/2DO, 2Relay, MID certified Ethernet 2DI/2DO, 2Relay Ethernet 2DI/2DO, 2Relay, MID certified Modbus and Ethernet, 4DI/2DO Modbus and Ethernet, MID certified RMICAN approved, HW lockable, 4DI/2DO RMICAN approved, factory sealed, 4DI/2DO DIN mount , no display Power meter, 4DI/2DO Remote Display for PM5563 Mechanical characteristics Weight IP degree of protection (IEC 60529) 250 g Designed to IP51 front display, IP30 meter body (Excluding connectors) Dimensions W x H x D 96 x 96 x 44 mm (depth of meter from housing mounting flange) 96 x 96 x 13 mm (protrusion of meter from housing flange) Mounting position Panel thickness Environmental characteristics Operating temperature Meter Display Storage temp. Humidity rating Pollution degree Altitude Meter + display Vertical 6.35 mm max -25 �C to 70 �C -20 �C to 70 �C (Display functions to -25 �C with reduced performance) -40 �C to 85 �C 5 % to 95 % RH at 50 �C (non-condensing) 2 < 3000 m max Indoor use only Not suitable for wet locations Electromagnetic compatibility Electrostatic discharge Immunity to radiated fields Immunity to fast transients Immunity to impulse waves Conducted immunity Immunity to magnetic fields Immunity to voltage dips Radiated emissions Conducted emissions Harmonics Flicker emissions Safety Europe IEC 61000-4-2g IEC 61000-4-3g IEC 61000-4-4g IEC 61000-4-5g IEC 61000-4-6g IEC 61000-4-8g IEC 61000-4-11g FCC part 15 class A, EN 55011 class A FCC part 15 class A, EN 55011 class A IEC 61000-3-2g IEC 61000-3-3g e, as per IEC 61010-1 3rd Edition U.S. and Canada UL 61010-1 and CAN/CSA-C22.2 No. 61010, 3rd Edition Measurement category (Voltage inputs) Per IEC 61010-1 CAT III, 20-277 V L-N / 20-480 V L-L CAT II, 20-400 V L-N / 20-690 V L-L Per UL 61010-1 and CSA C22.2 NO. 61010-1 CAT III, 20-300 V L-L Current Inputs (sensor connected) Require external Current Transformer for Insulation Overvoltage Category (Control power) CAT III Overvoltage Category (Relay) CAT II Dielectric withstand Protective Class As per IEC 61010-1 Double insulated front panel display Class II Double insulation at user-accessible area Included Communication RS-485 port Firmware and language file update Isolation 2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd, None, 1 stop bit if parity Odd or Even, 2 stop bits if None; Modbus RTU, Modbus ASCII (7 or 8 bit), JBUS Update via communication port using DLF3000 software 2.5 kVrms Human machine interface Display type Monochrome Graphics LCD Resolution 128 x 128 Backlight White LED Viewable area (W x H) 67 x 62.5 mm Keypad type 4-button Indicator Heartbeat / Comm activity Green LED Energy pulse output / Active alarm indication (configurable) Type Wavelength Maximum pulse rate Optical, amber LED 590 to 635 nm 2.5 kHz 92 Version: 1.0 - 24/01/2020 PLSED309005EN_05 PE86279 BASIC MULTI-FUNCTION METERING Rear of meter - open DIMENSIONS AND CONNECTION Rear view retainers - installation Rear view retainers - users PE86274 For detailed installation instructions see the product's Installation Guide. Version: 1.0 - 24/01/2020 93 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5000 series The PowerLogic PM5000 series power meters are the new benchmark in affordable, precision metering. The value you want, the precision you need. Compact, affordable power meters with high-end cost capabilities and basic mobile energy management. Applications Capable of essential cost management: � Sub-billing/tenant metering � Equipment sub-billing � Energy cost allocation Also ideal for electrical network management: � Track real-time power conditions � Monitor control functions � Provide basic power quality values � Detect and capture voltage sag and swell events � Monitor residual current � Analyze equipment and network status � BACnet/IP, Ethernet/IP, and DNP3.0 protocol support PB118061 METSEPM5760 94 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING The solution for Markets that can benefit from a solution that includes PowerLogic PM5000 series meters: � Buildings � Industry � Healthcare � Data Center and networks � Infrastructure Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance � Maximize uptime, eliminate faults, and enhance safety FUNCTIONS AND CHARACTERISTICS Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximize electrical network reliability and availability, and optimize electrical asset performance. Conformity of standards � IEC 61557-12 � IEC 62053-22 � IEC 62053-24 � IEEE 802.3 � EN 50470-1 � EN 50470-3 � IEC 61010-1 � IEC 61326-1 � CISPR22 Class B � ODVA certification � ANSI C12.1-2008 (PM55xx) � ANSI C12.20 Class 0.2 & 0.5 Competitive advantages � Easy to install and operate � Easy for circuit breaker monitoring and control � Power quality analysis � Load management combined with alarm and timestamping � High performance and accuracy � Residual Current Monitoring � Voltage sag and swell detection with waveform capture � MID ready compliance for legal billing application � BACnet/IP, Ethernet/IP, and DNP3.0 protocol support Version: 1.0 - 24/01/2020 95 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5000 series PM5000 series feature selection Installation PM5100 PM5100 PM5110 PM5310 PM5310R PM5300 PM5320 PM5320R PM5330 Fast installation, panel mount b b b b b b b with integrated display Fast installation, DIN rail mountable Accuracy Display Backlit LCD, multilingual, bar graphs, 6 lines, 4 concurrent values Power and energy metering 3-ph voltage, current, power, demand, energy, frequency, power factor Multi-tariff MID ready compliance, EN50470-1/3, Annex B & Annex D Class C Power quality analysis THD, thd, TDD Harmonics, individual (odd) up to Waveform capture & sag/ swell detection I/Os and relays I/Os Relays Analog inputs Residual Current inputs Alarms and control Alarms Set point response time, seconds Single and multi-condition alarms Boolean alarm logic � CL 0.5S b b � � b 15th � 1DO 0 � � 33 1 � � � CL 0.5S b b � PM5111 b 15th � 1DO 0 � � 33 1 � � � CL 0.5S b b 4 � b 31st � 2DI/2DO 0 � � 35 1 b � � CL 0.5S b b 4 � b 31st � 2DI/2DO 0 � � 35 1 b � � CL 0.5S b b 4 � b 31st � 2DI/2DO 0 � � 35 1 b � � CL 0.5S b b 4 � b 31st � 2DI/2DO 0 � � 35 1 b � � CL 0.5S b b 4 PM5331 b 31st � 2DI/2DO 2 � � 35 1 b � Memory for data logging � � 256KB 256KB 256KB 256KB 256KB Communications Serial ports with modbus protocol � 1 Ethernet port with Modbus TCP protocol � � BACnet/IP protocol � � Ethernet/IP protocol � � DNP3.0 over Ethernet � � Onboard web server with web pages � � Serial to Ethernet gateway � � Short ref. numbers PM5100 PM5110 (See table below for complete commercial reference numbers) 1 � � � � � � PM5310 1 � � � � � � PM5310R � 1 b � � � � PM5320 � 1 b � � � � PM5320R 1 � � � � � � PM5330 g 2 Ethernet ports for daisy chain, one IP address. NOTE: PM5310R and PM5320R must be used with Schneider Electric's "Quick Click" 3-in-1 LVCTs PM5340 b � CL 0.5S b b 4 PM5341 b 31st � 2DI/2DO 2 � � 35 1 b � 256KB � 1 b � � � � PM5340 96 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING PM5000 series FUNCTIONS AND CHARACTERISTICS PM5000 series feature selection PM5560 Installation Fast installation, panel mount with integrated b display Fast installation, DIN rail mountable � Accuracy CL 0.2S Display Backlit LCD, multilingual, bar graphs, 6 lines, 4 b concurrent values Power and energy metering 3-ph voltage, current, power, demand, energy, b frequency, power factor Multi-tariff 8 MID ready compliance, EN50470-1/3, Annex B & Annex D Class C PM5561 Power quality analysis THD, thd, TDD b Harmonics, individual (odd) up to 63rd Waveform capture & sag/ swell detection � I/Os and relays I/Os Relays Analog inputs Residual Current inputs Alarms and control Alarms Set point response time, seconds Single and multi-condition alarms Boolean alarm logic 4DI/2DO 0 0 0 52 1 b b PM5563 PM5500 PM5563RD PM5570 � � b b CL 0.2S b CL 0.2S � CL 0.2S � b b b b b 8 8 8 � � � b 63rd � b 63rd � b 63rd � 4DI/2DO 0 0 0 4DI/2DO 0 0 0 2DI/2DO 0 2 0 52 52 52 1 1 1 b b b b b b PM5580 PM5600 PM5650 PM5660 PM5700 PM5760 b b b b � CL 0.2S � CL 0.2S � CL 0.2S � CL 0.2S b b b b b b b b 8 8 8 8 � � PM5661 PM5761 b 63rd � b 63rd 8 cycles @ 128 cycles/ sec b 63rd � b 63rd 8 cycles @ 128 cycles/ sec 4DI/2DO 0 0 0 4DI/2DO 0 0 0 2DI/2DO 0 0 2 2DI/2DO 0 0 2 52 52 52 52 1 1 1 1 b b b b b b b b Memory for data logging 1.1 MB 1.1 MB 1.1 MB 1.1 MB 1.1 MB 1.1 MB 1.1 MB 1.1 MB Communications Serial ports with modbus protocol 1 1 1 Ethernet port with Modbus TCP protocol 2g 2g 2g BACnet/IP protocol b b b Ethernet/IP protocol b b b DNP3.0 over Ethernet b b b Onboard web server with b b b web pages Serial to Ethernet gateway b b b Short ref. numbers PM5560 PM5563 PM5563RD (See table below for complete commercial reference numbers) 1 2g b b b b b PM5570 1 2g b b b b b PM5580 1 2g b b b b b PM5650 1 2g b b b b b PM5660 1 2g b b b b b PM5760 g 2 Ethernet ports for daisy chain, one IP address. NOTE: PM5310R and PM5320R must be used with Schneider Electric's "Quick Click" 3-in-1 LVCTs Version: 1.0 - 24/01/2020 97 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING PM5000 series PM5000 technical specifications Use on LV and MV systems Basic metering with THD and min/max readings Instantaneous rms values Current Voltage per phase, neutral and ground (PM5500) Total, per phase L-L and L-N Frequency Real, reactive, and apparent power Total and per phase True Power Factor Total and per phase Displacement PF Total and per phase % Unbalanced I, V L-N, V L-L Direct monitoring of neutral current Energy values Accumulated Active, Reactive and Apparent Energy Demand value Current average Active power Reactive power Apparent power Peak demand with timestamping D/T for current and powers Demand calculation Sliding, fixed and rolling block, thermal methods Synchronisation of the measurement window to input, communication command or internal clock Settable Demand intervals Demand calculation for Pulse input (WAGES) Other measurements I/O timer Operating timer Load timer Alarm counters and alarm logs Power quality measurements THD, thd (Total Harmonic Distortion) I, VLN, VLL TDD (Total Demand Distortion) Individual harmonics (odds) Neutral Current metering with ground current calculation Waveform capture and sag/swell detection Data recording Min/max of instantaneous values, plus phase identificationg Alarms with 1s timestampingg Data logging Memory capacity Min/max log Maintenance, alarm and event logs Customisable data logs gStored in non-volatile memory PM5100 15th b FUNCTIONS AND CHARACTERISTICS PM5300 PM5500 b b PM5600 PM5700 b b b Signed, Four Quadrant Signed, Four Quadrant Signed, Four Quadrant b b Received/Delivered; Net and absolute; Time Counters Present, Last, Predicted, Peak, and Peak Date Time Present, Last, Predicted, Peak, and Peak Date Time Present, Last, Predicted, Peak, and Peak Date Time Present, Last, Predicted, Peak, and Peak Date Time b b b b b 31st b b b b I,VLN, VLL b 63rd b 8 cycles @ 128 cycles/sec b b 2 fixed parameters kWh and kVAh with configurable interval Up to 14 selectable parameters with configurable interval and & duration (e.g. 2 duration (e.g. 6 parameters for 90 days at 15-minute intervals) parameters for 60 days at 15-minute intervals) 256 KB 256 kB b b 1.1 MB b b b 98 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING PM5000 series FUNCTIONS AND CHARACTERISTICS PM5000 technical specifications PM5100 Inputs / Outputs / Mechanical Relays Digital inputs Digital outputs 1 (kWh only) PM5300 2 2 (configurable) PM5500 PM5600 PM5700 4 with WAGES for PM5560, PM5563, PM5580, PM5650 2 with WAGES for PM5570, PM5660, PM5760 2 (configurable) Form A Relay outputs 2 Analog inputs 2 for PM5570 Residual Current inputs Timestamp resolution in seconds Whetting source Type of measurement: True rms on three-phase (3P, 3P + N) IEC 61557-12 Active Energy Reactive Energy Active Power Measurement accuracy Apparent Power Current, Phase Voltage, L-N Frequency MID Directive EN50470-1, EN50470-3 Input-voltage (up to 1.0 MV AC max, with voltage transformer) Input-current (configurable for 1 or 5 A secondary CTs) Nominal Measured Voltage range Impedance Frequency nom I nom Measured Amps with over range and Crest Factor Withstand Impedance Frequency nom Burden Operating range AC control power Burden Frequency Ride-through time DC control power LV DC control power Operating range Burden Ride-through time 20-60 V DC �10 % CAT III Burden 4.1 W max. 2 for PM5660 2 for PM5760 1 1 1 1 1 24 V DC, 8 mA 64 samples per cycle 128 samples per cycle PMD/[SD|SS]/K70/0.5 Class 0.5S as per IEC 62053-22 Class 2 as per IEC 62053-23 Class 0.5 as per IEC 61557-12 PMD/[SD|SS]/K70/0.2 Class 0.2S as per IEC 62053-22 Class 2 as per IEC 62053-23 Class 0.2 as per IEC 61557-12 Class 0.5 as per IEC 61557-12 Class 0.5 as per IEC 61557-12 Class 0.5 as per IEC 61557-12 �0.05 % Annex B and Annex D (Optional model references) Class C 20 V L-N / 35 V L-L to 400 V L-N /690 V L-L absolute range 35 V L-L to 760 V L-L 20 V L-N / 20 V L-L to 400 V L-N /690 V L-L absolute range 20 V L-L to 828 V L-L 50 or 60 Hz �5 % 5 M 5 A 50 or 60 Hz �10 % Starting current: 5 mA Operating range: 50 mA to 8.5 A Starting current: 5 mA Operating range: 50 mA to 10 A 50 or 60 Hz �5 % Continuous 20 A, 10 s/hr 50 A, 1s/hr 500 A < 0.3 m 50 or 60 Hz �10 % <0.026 VA at 8.5 A 100 - 277 V AC L-N / 415 V L-L +/-10 % CAT III 300V class per IEC 61010 100-480 V AC �10 % CAT III 600V class per IEC 61010 <5 W,11 VA at 415V L-L 80 mS typical at 120V AC and maximum burden. 100 mS typical at 230 V AC and maximum burden 100 mS typical at 415 V AC and maximum burden 45 to 65 Hz <5W/16.0 VA at 480 V AC 35 ms typical at 120 V L-N and maximum burden 129 ms typical at 230 V L-N and maximum burden 125-250 V DC �20 % <4 W at 250 V DC typical 3.1W at 125 V DC, max. 5W 50 mS typical at 125 V DC and maximum burden b PM5580 Version: 1.0 - 24/01/2020 99 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5000 series PM5000 technical specifications PM5100 PM5300 PM5500 PM5600 PM5700 Max output frequency 0.5 Hz maximum (1 second ON / 1 second OFF - min times) Relay Switching current 250 V AC at 8.0 Amps, 25 k cycles, resistive 30 V DC at 2.0 Amps, 75 k cycles, resistive 30 V DC at 5.0 Amps, 12.5 k cycles, resistive Isolation 2.5 kV rms Max load voltage 40 V DC 30 V AC / 40 V DC PM5570, PM5560, PM5561, PM5760, PM5761 Max load current 20 mA 125 mA Outputs On Resistance Meter constant 50 max 8 from 1 to 9,999,999 pulses per kWh Pulse width for Digital Output 50 % duty cycle Pulse frequency for Digital Output 25 Hz max. Leakage current 0.03 micro Amps 1 micro Amps Isolation 5 kV rms 2.5 kV rms Optical outputs Pulse width (LED) Pulse frequency Meter constant 50 Hz. max. 200 ms 2.5 kHz. max from 1 to 9,999,999 pulses per k_h Status Inputs ON Voltage OFF Voltage Input Resistance Maximum Frequency Response Time Opto Isolation Whetting output Input Burden Analog inputs Residual Current inputs Mechanical characteristics Product weight IP degree of protection (IEC 60529) 18.5 to 36 V DC 110 k 2 Hz (T ON min = T OFF min = 250 ms) 20 ms 5 kV rms 24 V DC/ 8 mA max 2mA @24V DC 0 to 4 V DC 30 V AC / 60 V DC max 100 k 25 Hz (T ON min = T OFF min = 20 ms) 10 ms 2.5 kV rms 2 mA @ 24 V AC/DC 4 - 20 mA DC (nominal) Accuracy: 1% of full-scale reading < 20 ohm Operating voltage: 24 V DC max 5 uA to 1,200 uA (nominal), 1,500 uA max (continuous)Input type: AC 45 to 65 Hz Burden: 150 ohms Default toroid: 1000 turns 380 g 430 g 450 g 450 g IP52 front display, (IP54 for PM53xx and PM55xx), IP30 meter body 450 g Dimensions W x H x D [protrusion from cabinet] 96 x 96 x 72 mm (77 mm for PM5500) (depth of meter from housing mounting flange) [13 mm] Mounting position Panel thickness Environmental characteristics Meter Display (Display functions to -25� with reduced performance) Storage temp. Humidity range Pollution degree Altitude Vertical 6 mm maximum -25 �C to 70 �C -25 �C to 70 �C -40 �C to 85 �C 5 to 95 % RH at 50 �C (non-condensing) 2 2000 m CAT III / 3000 m CAT II 3000 m max. CAT III 100 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5000 series PM5000 technical specifications Electromagnetic compatibility Harmonic current emissions Flicker emissions Electrostatic discharge Immunity to radiated fields Immunity to fast transients Immunity to surge Conducted immunity 150 kHz to 80 MHz Immunity to magnetic fields Immunity to voltage dips Radiated emissions Conducted emissions Safety Europe U.S. and Canada Measurement category (Voltage & Current inputs) Dielectric Protective Class PM5100 IEC 61000-3-2 IEC 61000-3-3 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 FCC part 15, EN 55022 Class B FCC part 15, EN 55022 Class B PM5300 PM5500 PM5600 CE, as per IEC 61010-1 Ed. 3, IEC 62052-11 & IEC 61557-12 cULus as per UL 61010-1 (3rd Edition) CAT III up to 400 V L-N / 690 V L-L As per IEC/UL 61010-1 Ed. 3 II, Double insulated for user accessible parts PM5700 RS-485 port Modbus RTU, Modbus ASCII Ethernet port: 10/100 Mbps; Modbus TCP/IP Native Ethernet/IP & DNP3.0 over Ethernet 2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd, None, 1 stop bit if parity Odd or Even, 2 stop bits if None; 1 Optional 2 (daisy chain only, 1 IP address) Yes Yes Yes Firmware and language file update Isolation Human machine interface Display type Resolution Backlight Viewable area (W x H) Keypad Indicator Heartbeat / Comm activity Energy pulse output / Active alarm (configurable) Wavelength Maximum pulse rate Meter firmware update via the communication ports 2.5 kVrms, double insulated Monochrome Graphics LCD 128 x 128 White LED 67 x 62.5 mm 4-button Green LED Optical, amber LED 590 to 635 nm 2.5 kHz Version: 1.0 - 24/01/2020 PLSED309005EN_05 101 BASIC MULTI-FUNCTION METERING FUNCTIONS AND CHARACTERISTICS PM5xxx series commercial reference numbers Comm ref numbers METSEPM5100 Description Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 15th harmonic, no communication, 1DO METSEPM5110 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 15th harmonic, RS-485 Modbus, 1DO METSEPM5111 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 15th harmonic, RS-485 Modbus, 1DO, MID cert. METSEPM5310 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RS-485 Modbus, 2DI/2DO METSEPM5310R Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RJ45 LVCT, RS-485 Modbus, 2DI/2DO METSEPM5320 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, Ethernet, 2DI/2DO METSEPM5320R Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RJ45 LVCT, Ethernet, 2DI/2DO METSEPM5330 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RS-485 Modbus, 2DI/2DO, 2Relay METSEPM5331 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RS-485 Modbus, 2DI/2DO, 2Relay, MID cert. METSEPM5340 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, Ethernet, 2DI/2DO, 2Relay METSEPM5341 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, Ethernet, 2DI/2DO, 2Relay, MID cert. METSEPM5560 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, Modbus and Ethernet, 4DI/2DO METSEPM5561 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, Modbus and Ethernet, MID cert. METSEPM5562 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, RMICAN approved, HW lockable, 4DI/2DO METSEPM5562MC Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, RMICAN approved, factory sealed, 4DI/2DO METSEPM5563 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, DIN mount, no display, 4DI/2DO METSEPM5563RD Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, DIN mount, remote display, 4DI/2DO METSEPM5570 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, Modbus and Ethernet, 2DI/2DO/2AI METSEPM5580 Power Meter range 77 mm depth, control power 24-60 VDC, Cl 0.2S, 63rd harmonic, 1.1 MB, Modbus and Ethernet, 4DI/2DO METSEPM5650 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, waveform capture and sag/swell, 1.1 MB, Modbus and Ethernet, 2DI/2DO, RCM METSEPM5660 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, Modbus and Ethernet, 2DI/2DO, RCM METSEPM5661 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, Modbus and Ethernet, 2DI/2DO, RCM, MID METSEPM5760 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, waveform capture and sag/swell, 1.1 MB, Modbus and Ethernet, 2DI/2DO, RCM METSEPM5761 Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, waveform capture and sag/swell, 1.1 MB, Modbus and Ethernet, 2DI/2DO, RCM, MID cert. Residual Current Monitoring Toroids (Vigirex) Closed Toroids, A Type 50437 TA30 - 30 mm inside diameter, Ie (A) 65, 1000 turns 50438 PA50 - 50 mm inside diameter, Ie (A) 85, 1000 turns 50439 IA80 - 80 mm inside diameter, Ie (A) 160, 1000 turns 50440 MA120 - 120 mm inside diameter, Ie (A) 250, 1000 turns 50441 SA200 - 200 mm inside diameter, Ie (A) 400, 1000 turns 50442 GA300 - 300 mm inside diameter, Ie (A) 630, 1000 turns Accessories for Closed Toroids 56055 Magnetic ring for TA30 toroid 56056 Magnetic ring for PA50 toroid 56057 Magnetic ring for IA80 toroid 56058 Magnetic ring for MA120 toroid Split Toroids, OA Type 50420 TOA80 - 80 mm inside diameter, Ie (A) 160, 1000 turns 50421 TOA120 - 120 mm inside diameter, Ie (A) 250, 1000 turns 56053 L1 - 280 x 115 mm inside diameter, Ie (A) 1600, 1000 turns 56054 L2 - 470 x 160 mm inside diameter, Ie (A) 3200, 1000 turns 102 Version: 1.0 - 24/01/2020 PLSED309005EN_05 BASIC MULTI-FUNCTION METERING PM5xxR series commercial reference numbers Comm. ref numbers Description 0.333V 3-in-1 CTs with RJ45 for PM53x0R METSECTV25006 METSECTV25010 METSECTV25013 METSECTV25016 METSECTV35006 METSECTV35010 METSECTV35012 METSECTV35013 METSECTV35015 METSECTV35016 METSECTV35020 METSECTV35025 METSECTV45025 METSECTV45030 METSECTV45040 METSECTV45050 METSECTV45060 METSECTV45063 METSECTV29006 METSECTV29010 METSECTV29012 METSECTV29013 METSECTV29015 METSECTV29016 METSECTV29020 METSECTV70080 METSECTV70100 METSECTV70125 LVCT SolidC 3in1 RJ45 25mmCtr 60A:1/3V LVCT SolidC 3in1 RJ45 25mmCtr 100A:1/3V LVCT SolidC 3in1 RJ45 25mmCtr 125A:1/3V LVCT SolidC 3in1 RJ45 25mmCtr 160A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 60A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 100A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 120A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 125A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 150A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 160A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 200A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 250A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 250A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 300A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 400A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 500A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 600A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 630A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 60A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 100A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 120A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 125A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 150A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 160A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 200A:1/3V LVCT SolidC 3in1 RJ45 70mmCtr 800A:1/3V LVCT SolidC 3in1 RJ45 70mmCtr 1000A:1/3V LVCT SolidC 3in1 RJ45 70mmCtr 1250A:1/3V Cables DCEPCURJX5GYM DCEPCURJ01GYM DCEPCURJ02GYM DCEPCURJ03GYM DCEPCURJ05GYM Category 5e, Patch Cord, UTP, 0.5 M, Grey Category 5e, Patch Cord, UTP, 1 M, Grey Category 5e, Patch Cord, UTP, 2 M, Grey Category 5e, Patch Cord, UTP, 3 M, Grey Category 5e, Patch Cord, UTP, 5 M, Grey DCEPCURJ10GYM Category 5e, Patch Cord, UTP, 10 M, Grey Other related products METSEPM5RD Remote display for PM5563 METSEPM51HK Hardware kit for PM51xx METSEPM53HK Hardware kit for PM53xx METSEPM51_3RSK Revenue sealing kit for PM51XX & PM53XX METSEPM55RSK Revenue sealing kit for PM55XX METSEPM55HK Hardware kit for PM55xx METSEPM5CAB3 Remote Display cable See your Schneider Electric representative for complete ordering information. FUNCTIONS AND CHARACTERISTICS Version: 1.0 - 24/01/2020 PLSED309005EN_05 103 BASIC MULTI-FUNCTION METERING PM5000 series PM5000 Series meter flush mounting DIMENSIONS AND CONNECTION PB111276m PB111279_m PB111278 PM5000 series meter dimensions PB111279A PB111289 PM5000 PM5100 / PM5300 PM5500 / PM5600 PB111291 PB111277 PM5500 PM5000 meter parts A Menu selection buttons B LED indicators C Navigation or menu selections D Maintenance and alarm notification area PM5500 / PM5600 meter parts E Voltage inputs F RS-485 comms G Digital inputs H Current inputs I Digital outputs J Ethernet ports K Control power PM5100 / PM5300 meter parts E Relay output (PM5300 only) F Voltage inputs G Control power H Current inputs I Status inputs/digital outputs J Communications port: Ethernet (PM5300 only) or RS-485) Please see the appropriate Installation Guide for accurate and complete information on the installation of this product. 104 Version: 1.0 - 24/01/2020 PLSED309005EN_05 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS Advanced metering Advanced high performance meters are designed for mains or critical loads on MV/LV networks. They provide analysis of efficiency, losses and capacity, bill verification, power quality compliance monitoring, problem notification and diagnosis and control of loads, etc. Power quality meters are classified as advanced meters designed to monitor service entrances and critical network locations to maximize power availability and reliability by providing a comprehensive system load profile, power quality and root cause analyses. � � PowerLogicTM PM8000 � � PowerLogicTM ION9000 PB113687 P115913 METSEPM8240 Version: 1.0 - 27/08/2020 PLSED309005EN_06 M7650 105 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS PM8000 Series The PowerLogicTM PM8000 series meters are compact, cost-effective multifunction power meters that will help you ensure reliability and efficiency of your power-critical facility. Reveal and understand complex power quality conditions. Measure, understand and act on insightful data gathered from your entire power system. Designed for key metering points throughout your energy infrastructure, the PowerLogic PM8000 series meter has the versatility to perform nearly any job you need a meter to do, wherever you need it! Applications Ideal for low to high voltage applications in industrial facilities, data centers, infrastructure and other critical power environments. PB113687 106 METSEPM8240 Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS PM8000 series The solution for Markets that can benefit from a solution that includes PowerLogic PM8000 series meters: � Industry � Data centers � Infrastructure � Healthcare � Buildings Benefits � Makes understanding power quality simple to help operations personnel avoid downtime and helps ensure increased productivity and equipment life. � Makes energy and power quality immediately relevant and actionable to support your operational and sustainability goals. Competitive advantages � Modular, flexible patented ION technology architecture enables a simple building block approach. � Disturbance direction detection, modularity and compliance with latest power quality standards. � Color screen. � Multiple communication options. � Excellent accuracy. Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximize electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � EN 50160 � IEC 62053-11 � EN 50470 � IEC 62053-22 � IEC 61000-4-30 � IEC 62053-23 � IEC 61010-1 � IEC 62053-24 � IEC 61326-1 � IEC 62586-2 � IEC 61557-12 � IEEE 519 � IEC 62052-11 � UL 61010-1 Version: 1.0 - 27/08/2020 PLSED309005EN_06 107 PB113692 PB113668 PB113641 ADVANCED METERING PM8000 series PowerLogic PM8000 series meter. PowerLogic PM8000 series meter - rear view. PowerLogic PM8000 DIN rail mounted meter. 108 FUNCTIONS AND CHARACTERISTICS Main characteristics � Precision metering: � IEC 61557-12 PMD/SD/K70/0.2 and PMD/SS/K70/0.2 3000m (performance measuring and monitoring functions). � Class 0.2S accuracy IEC 62053-22, ANSI C12.20 Class 0.2 (active energy). � Industry leading Class 0.5S accuracy for reactive energy (IEC 62053-24). � Cycle-by-cycle RMS measurements updated every � cycle. � Full `multi-utility' WAGES metering support. � Net metering. � Anti-tamper protection seals. � PQ compliance reporting and basic PQ analysis: � Monitors and logs parameters in support of international PQ standards, � IEC 61000-4-30 Class S (test methods as per IEC 62586-2). � Generates onboard PQ compliance reports accessible via onboard web pages: � Basic event summary and pass/fail reports, for EN 50160 for power frequency, supply voltage indication, supply voltage dips, short and long interruptions, temporary over voltages, voltage unbalance and harmonic voltage. � ITIC (CBEMA) and SEMI curves, with alarm categorization to support further analyses. � NEMA Motor Derating curve. � Pass/fail report for IEEE 519 for voltage and current harmonic limits. � Harmonic analysis: � THD on voltage and current, per phase, min/max, custom alarming. � Individual harmonic magnitudes and angles on voltage and current, up to the 63rd harmonic. � High resolution waveform capture: triggered manually or by alarm, captured waveforms available directly from the meter via FTP in a COMTRADE format. � Disturbance detection and capture: sag/swell on any current and voltage channel, alarm on disturbance event, waveform capture with pre-event information. � Patented disturbance direction detection: provides indication of the captured disturbance occurring upstream or downstream of the meter; timestamped results provided in the event log, with degree of certainty of disturbance direction. � Used with Schneider Electric's sophisticated software tools, provides detailed PQ reporting across entire network: � EN 50160 report. � IEC 61000-4-30 report. � IEEE 519 harmonic compliance report. � PQ compliance summary. � Display of waveforms and PQ data from all connected meters. � Onboard web-based waveform viewer. � Energy reports for consumption analysis and cost management. � WAGES dashboards and reports. � EcoStruxure Power Events Analysis, including alarm management, sequence of events, and root cause analysis. � Cybersecurity: � Security events logging with Syslog protocol support. � HTTPS secure protocol. � Ability to enable or disable any communication port and any protocol per port. � Anti-tamper protection seals and hardware metrology lock. � User accounts with strong passwords. � Data and event logging: � Onboard data and event logging. � 512 MB of standard non-volatile memory. Version: 1.0 - 27/08/2020 PLSED309005EN_06 PB113669 PB113671 ADVANCED METERING PM8000 series PowerLogic PM8000 series meter with remote display. PowerLogic I/O module. FUNCTIONS AND CHARACTERISTICS M Main characteristics Main characteristics (contd.) � No data gaps due to network outages or server downtime. � Min/Max log for standard values. � 50 user-definable data logs, recording up to 16 parameters on a cycle-by- cycle or other user definable interval. � Continuous logging or `snapshot' triggered by setpoint and stopped after defined duration. � Trend energy, demand and other measured parameters. � Forecasting via web pages: average, minimum and maximum for the next four hours and next four days. � Advanced time-of-use capability. � Security / event log: alarm conditions, metering configuration changes, power outages, firmware download, and user login/logout all timestamped to �1 millisecond. � Alarming and control: � 50+ definable alarms to log critical event data, trigger waveform recording, or perform control function. � Trigger on any condition, with 1/2-cycle and 1-second response time. � Combine alarms using Boolean logic and to create alarm levels. � Alarm notification via email. � In conjunction with Schneider Electric's EcoStruxure software, alarms, software alarms, and alarm frequency are categorized and trended enabling sequence of events and root cause analyses. Usability � Easy installation and setup: � Panel and DIN rail mounting options, remote display option. � Pluggable connectors. � Free setup application simplifies meter configuration. � Auto-discovery using DPWS (Device Profile Web Services). � DHCP for automatic IP address configuration. � Front panel: � Easy to read color graphic display. � Simple, intuitive menu navigation with multi-language (8) support. � Flexible remote communications: � Multiple simultaneously operating communication ports and protocols allow interfacing with other automation systems; (e.g. waveforms, alarms, billing data, etc.) can be uploaded for viewing/analysis while other systems access real-time information. � Supports Modbus, ION, DNP3, IEC 61850. � Dual port Ethernet: 10/100BASE-TX; supports IPV4 and IPV6; daisychaining capability removes need for additional switches. � Secure web interface with HTTPS and TLS 1.2 with support for userprovided certificates. � Create redundant network loop using Rapid Spanning Tree Protocol (RSTP) and managed Ethernet switches. � Customize TCP/IP port numbers and enable/disable individual ports. � RS-485 2-wire connection, up to 115,200 baud, Modbus RTU, ION and DNP3 protocols. � Ethernet to serial gateway with Modbus Master functionality, connecting to 31 downstream serial Modbus devices. Also supports Modbus Mastering over TCP/IP (Ethernet) network. � Full function web server with factory and customizable pages to access real-time and PQ compliance data. � Push historical data via email. � Advanced security: Up to 50 configurable user accounts. Version: 1.0 - 27/08/2020 PLSED309005EN_06 109 PB113686 PB119094 ADVANCED METERING PM8000 series PowerLogic PM8000 series meter with I/O modules. PowerLogic PM8000 series waveform web page sample FUNCTIONS AND CHARACTERISTICS � Time synchronization via: � GPS clock (RS-485) or IRIG-B (digital input) to �1 millisecond. � Network Time Protocol (NTP/SNTP). � Precision Time Protocol (PTP - IEEE 1588 / IEC 61588). � Time set function from Schneider Electric software server. Adaptability � IONTM frameworks allow customisable, scalable applications, object-oriented programming, compartmentalizes functions, and increases flexibility and adaptability. � Applications include: access and aggregate data from Modbus devices on serial port or across the network (Modbus TCP/IP), logging and/or processing data by totaling, unit conversion or other calculations, applying complex logic for alarming or control operations, data visualization via web pages. Standard meter I/O � 3 digital status/counter inputs. � 1 KY (form A) energy pulse output for interfacing with other systems. Modular I/O options � Optional expansion modules. � Up to 4 modules per meter. Option modules include: � Digital module: � 6 digital status/counter inputs. � 2 Form C relay outputs, 250 V, 8 A. � Analog module: � 4 analog inputs (4-20 mA; 0-20 mA; 0-30 V). � 2 analog outputs (4-20 mA; 0-20 mA; 0-10 V) for interfacing with building management sensors and systems. PowerLogic PM8000 series CBEMA web page sample PB119093 PB119095 PowerLogic PM8000 series PQ harmonics web page sample 110 Version: 1.0 - 27/08/2020 PLSED309005EN_06 PB113696 ADVANCED METERING PM8000 series FUNCTIONS AND CHARACTERISTICS Underside of PM8000 meter (DIN rail version). Feature selection Commercial reference number METSEPM8240 METSEPM8210 METSEPM8243 METSEPM8213 METSEPM8244 METSEPM8214 Description 96 x 96 panel mount meter, AC/DC power. 96 x 96 panel mount meter, LV DC power. DIN rail mount meter, AC/DC power. DIN rail mount meter, LV DC power. DIN rail mount meter with remote display, AC/DC power. DIN rail mount meter with remote display, LV DC power. METSEPM82401 MID approved panel mount meter. METSEPM82403 METSEPM82404 RMICAN approved panel mount meter. RMICAN sealed panel mount meter. Accessories Description METSEPM89RD96 Remote display, 3 metre cable, mounting hardware for 30 mm hole (nut & centering pin), mounting hardware for DIN96 cutout (92 x 92 mm) adapter plate METSEPM89M2600 Digital I/O module (6 digital inputs & 2 relay outputs) METSEPM89M0024 Analog I/O module (4 analog inputs & 2 analog outputs) METSEPM8HWK Replacement hardware kit (connectors, screws, retainer clips, mounting template) Feature guide General Use on LV, MV, and HV systems Current accuracy Voltage accuracy Active energy accuracy Number of samples/cycle or sample frequency Instantaneous rms values Current, voltage, frequency Active, reactive, apparent power Power factor Current measurement range (autoranging) Total and per phase Total and per phase Energy values Active, reactive, apparent energy Settable accumulation modes Demand values Current Present and max. values Active, reactive, apparent power Present and max. values Predicted active, reactive, apparent power Synchronization of the measurement window Setting of calculation mode Block, sliding Power quality measurements Harmonic distortion Current and voltage Individual harmonics Via front panel and web page Via EcoStruxureTM software Waveform capture Detection of voltage swells and sags Fast acquisition 1/2 cycle data EN 50160 compliance checking IEEE 519 compliance checking Customizable data outputs (using logic and math functions) Data recording Min/max of instantaneous values Data logs Event logs Trending/forecasting SER (Sequence of event recording) Time stamping GPS synchronization (+/- 1 ms) Memory (in Mbytes) Display and I/O Front panel display Wiring self-test Pulse output Digital or analog inputs(max) Digital or analog outputs (max, including pulse output) Communication RS-485 port Ethernet port Serial port (Modbus, ION, DNP3) Ethernet port (Modbus/TCP, ION TCP, DNP3 TCP, DHCP, DNS, IPv4, IPv6, IEC 61850) Ethernet gateway Alarm notification via email HTTP/HTTPs web server with waveform viewer SNMP with custom MIB and traps for alarms SMTP email PTP and NTP time synchronization FTP file transfer PM8000 b 0.1 % reading 0.1 % reading 0.2 Class 256 b b b 0.05 - 10 A b b b b b b b b 63 127 b b b b b b b b b b b b b 512 b b 1 27 digital 16 analog 1 digital 8 relay 8 analog 1 2 b b b b b b b b b Version: 1.0 - 27/08/2020 PLSED309005EN_06 111 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS PM8000 series Technical specifications Electrical characteristics Type of measurement Current & voltage Active Power Power factor Measurement accuracy Frequency Active energy Reactive Energy MID Directive Display refresh rate Specified accuracy voltage Input-voltage characteristics Impedance Specified accuracy frequency - Frequency Input-current characteristics Limit range of operation frequency Rated nominal current Specified accuracy current range Permissible overload Impedance Burden AC DC Power supply AC/DC Ride-through time Burden Power supply LV DC DC Burden Input/outputs Meter Base Only Optional Mechanical characteristics Weight IP degree of protection Excellent quality Dimensions Panel mount model DIN model Remote display IO modules True rms to 256 samples per cycle Class 0.2 as per IEC 61557-12 Class 0.2 as per IEC 61557-12 Class 0.5 as per IEC 61557-12 Class 0.02 as per IEC 61557-12 Class 0.2S IEC 62053-22 Class 0.2 IEC 61557-12, ANSI C12.20 Class 0.2 Class 0.5S IEC 62053-24* EN 50470-1, EN 50470-1, AnnexB & AnnexD (optional model) 1/2 cycle or 1 second 57 - 400 V L-N / 100 - 690 V L-L 5 MW per phase 42 to 69 Hz (50/60 Hz nominal) 20 to 450 Hz 1 A (0.2S), 5 A (0.2S) , 10 A (0.2 ANSI) Starting Current: 5 mA Accurate Range: 50 mA - 10 A 200 A rms for 0.5s, non-recurring 0.0003 W per phase 0.01 VA max at 5 A 90-415 V AC �10 % (50/60 Hz �10 %) 90-120 V AC +/- 10% (400 Hz) 110-415 V DC �15 % (20-60 V DC �10 % for PM8210 100 ms (6 cycles at 60 Hz) min., any condition 200 ms (12 cycles at 60 Hz) typ., 120 V AC 500 ms (30 cycles at 60 Hz) typ., 415 V AC Typical: 7.7 W / 16 VA at 230 V (50/60 Hz) Fully optioned: max. 18 W / 40 VA at 415 V (50/60 Hz). 20 to 60 V DC �10 % Fully optioned: max. 18 W at 18 to 60 V DC 3 digital inputs (30 V AC/60 V DC) 1 form A (KY) solid state digital output (30 V AC/60 V DC, 75 mA). Digital - 6 digital inputs (30 V AC / 60 V DC) wetted + 2 form C relay outputs (250 V AC, 8 A) Analog - 4 analog inputs (4-20 mA, 0-30 V DC) + 2 analog outputs (4-20 mA, 0-10 V DC). Integrated Display Model 0.581 kg DIN rail mounted Model 0.528 kg IO modules 0.140 kg Remote display 0.300 kg IP 54, UL type 12: Panel mount and Remote display, front. IP 30: Panel mount rear, DIN rail mount, I/O modules. ISO 9001 and ISO 14000 certified manufacturing. 96 x 96 x 77.5 mm 90.5 x 90.5 x 90.8 mm 96 x 96 x 27 mm 90.5 x 90.5 x 22 mm 112 Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS PM8000 series Environmental conditions Operating temperature Remote Display Unit -25 �C to 70 �C -25 �C to 60 �C Storage temperature -40 �C to 85 �C Humidity rating Installation category Operating altitude (maximum) Electromagnetic compatibility 5 % to 95 % non-condensing III 3000 m above sea-level EMC standards IEC 62052-11 and IEC 61326-1 Immunity to electrostatic discharge IEC 61000-4-2 Immunity to radiated fields Immunity to fast transients Immunity to surges IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 Immunity to conducted disturbances IEC 61000-4-6 Immunity to power frequency magnetic fields Immunity to conducted disturbances, 2-150kHz Immunity to voltage dips & interruptions Immunity to ring waves IEC 61000-4-8 CLC/TR 50579 IEC 61000-4-11 IEC 61000-4-12 Conducted and radiated emissions EN 55022, EN 55011, FCC part 15 Class B, EN55011, EN55022 Class B, ICES-003 Class B Surge withstand Capability (SWC) IEEE / ANSI C37.90.1 Safety Safety Construction Communication IEC/EN 61010-1 ed.3, CAT III, 400 V L-N / 690 V L-L UL 61010-1 ed.3 and CSA-C22.2 No. 61010-1 ed.3, CAT III, 347 V L-N / 600 V L-L IEC/EN 62052-11, protective class II. Ethernet to serial line gateway Communicates directly with up to 31 unit load devices. Web server Customisable pages, new page creation capabilities, HTML/XML compatible. Serial port RS-485 Baud rates of 2400 to 115200, pluggable screw terminal connector. Ethernet port(s) 2x 10/100BASE-TX, RJ45 connector (UTP). Protocol Modbus, ION, DNP3, IEC 61850, HTTPS, FTP, SNMP, SMTP, DPWS, RSTP, NTP, PTP, NTP/SNTP, GPS, IPv4 /IPv6, DHCP, Syslog protocols. Firmware characteristics High-speed data recording Down to 1/2 cycle interval burst recording, stores detailed characteristics of disturbances or outages. Trigger recording by a user-defined setpoint, or from external equipment. Harmonic distortion Up to 63rd harmonic (127th via Schneider Electric software) for all voltage and current inputs. Sag/swell detection Analyse severity/potential impact of sags and swells: magnitude and duration data suitable for plotting on voltage tolerance curves per phase triggers for waveform recording, control. Disturbance direction detection Determine the location of a disturbance more quickly and accurately by determining the direction of the disturbance relative to the meter. Analysis results are captured in the event log, along with a timestamp and confidence level indicating level of certainty. Instantaneous High accuracy of standard speed (1s) and high-speed (1/2 cycle) measurements, including true rms per phase and total for: voltage, current, active power (kW),reactive power (kvar), apparent power (kVA), power factor, frequency, voltage and current unbalance, phase reversal. Load profiling Channel assignments (800 channels via 50 data recorders) configurable for any measurable parameter, including historical trend recording of energy, demand, voltage, current, power quality, or any measured parameter. Trigger recorders based on time interval, calendar schedule, alarm/event condition, or manually. Trend curves Historical trends and future forecasts to better manage demand, circuit loading, and other parameters. Provides average, min, max and standard deviation every hour for last 24 hours, every day for last month, every week for last 8 weeks and every month for last 12 months. Waveform captures Simultaneous capture of all voltage and current channels, sub-cycle disturbance capture, ability to record from 210 cycles at 256 sample per cycle to over 2880 cycles at 16 points per cycle with user selectable sampling speed as well as pre- and post-trigger length. Alarms Threshold alarms: adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm, user-defined or automatic alarm threshold settings, user-defined priority levels (optional automatic alarm setting). Advanced Time of Use (TOU) 6 seasons; 3 different day types: weekend, weekday, and holiday; up to 8 tariffs per day type. Version: 1.0 - 27/08/2020 PLSED309005EN_06 113 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS PM8000 series Firmware characteristics (cont.) Advanced security Up to 50 users with unique access rights. Perform resets, time sync, or meter configurations based on user privileges. Memory 512 MB. Firmware update Display characteristics Update via the communication ports. Integrated or Remote display 320 x 240 (1/4 VGA) Color LCD, configurable screens , 5 buttons and 2 LED indicators (alarm and meter status). Languages English, French, Spanish, Russian, Portugese, German, Italian, Chinese. Notations IEC, IEEE. The HMI menu includes Alarms Active alarms, historic alarms (50+ alarms). Basic Reading Voltage, current, frequency, power summary. Power Power summary, demand, power factor. Energy Energy total, delivered, received. Events Timestamped verbose event log. Power Quality EN 50160, IEEE 519, harmonics, phasor diagrams. Inputs/Outputs Digital inputs, digital outputs, analog inputs, analog outputs. Nameplate Model, serial and FW version. Custom Screens Build your own metrics. Setup Menu Meter setup, communications setup, display setup, date/time/clock setup, alarm setup, language setup, time of use setup, resets, password setup. PM8000 series parts PB119092 PB113642 A Voltage inputs B Control power C Digital inputs D Revenue lock LED (green) E Status LED (green/red) F Revenue lock switch G Digital output H Sealing gasket I Infrared energy pulsing LED J Energy pulsing LED K RS-485 L Current inputs M Ethernet (2) N Date/time O Revenue lock icon P Alarm icon Q Display R Navigation icons Up Down Select Cancel Edit More S Navigation buttons T Home button U Alarm LED (red) V Bar graph 114 Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED METERING PM8000 series PM8000 panel mount meter dimensions DIMENSIONS AND CONNECTION PB119087 PB119088 PB119089 PM8000 DIN rail mount meter dimensions PM8000 remote display dimensions PM8000 with I/O modules dimensions PB119086 Please see the appropriate Installation Guide for accurate and complete information on the installation of this product. Version: 1.0 - 27/08/2020 PLSED309005EN_06 115 PB119090 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS ION9000 Series The PowerLogicTM ION9000 is your 24/7 power quality expert, providing information, not just data. With a comprehensive, industry-leading Power Quality Instrument (PQI) performance designation according to IEC 625861/-2, the PowerLogic ION9000 is third-party certified ANSI C12.20 Class 0.1 and IEC 62053-22 Class 0.1S accurate, the most accurate power meter available today. Lab-verified power quality and safety ensure reliable, precision performance that is perfect for supply- or demand-side applications. Its patented Disturbance Direction Detection also helps you pinpoint the source of power quality issues faster. Capable of sampling at 10 MHz, the ION9000T captures extremely fast voltage events that are missed by most other power meters, enabling advanced diagnostics and high-resolution event associations for fast, conclusive diagnosis and resolution to transient voltages. Highly customizable and modular, the ION9000's field programmability can adapt to satisfy any solution, protecting your investment now and in the future. All designed to align with your comprehensive grid cybersecurity policies and backed by Schneider Electric's global services and support. Applications Ideal for critical power and large energy users who cannot afford to be shut down, the ION9000T has High-Speed Transient Capture (HSTC) to detect and record transient events that exceed the voltage withstand of sensitive equipment. PB115917 116 METSEION92040 Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS The market solution for Markets that benefit from a solution that includes PowerLogic ION9000 series meters: � Data centers � Healthcare facilities � Semiconductor � Pharmaceutical & chemical � Energy industries � Mining, Minerals, & Metals � Renewable energy interconnects � Medium voltage distribution & energy automation Benefits � Makes understanding power quality simple which helps operations personnel avoid downtime and increase productivity and equipment life � Makes energy and power quality data immediately actionable and relevant to operational and sustainability goals Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings. Maximize electrical network reliability and availability, and optimize electrical asset performance. Conformity of standards � ANSI C12.20 � IEC 62052-11 � ANSI C37.90.1 � IEC 62052-31 � IEC 61000-4-15 � IEC 62053-22 � IEC 61000-4-30 � IEC 62053-23 � IEC 61010-1 � IEC 62053-24 � IEC 61326-1 � IEC 62586 � IEC 61557-12 � UL 61010-1 � IEC 61850 Competitive advantages � Modular, flexible, patented IONTM programmable technology � Utility grade energy accuracy � Patented Disturbance Direction Detection � Third-party, lab-verified compliance with latest PQ standards � Onboard pass/fail PQ characterization and assessment according to EN50160 and IEEE519 � Cybersecurity event logging, Syslog protocol, HTTPS, SFTP, and full control of each communication port � High-speed impulsive and oscillatory transient detection Version: 1.0 - 27/08/2020 PLSED309005EN_06 117 PB115917 PB115914 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS PowerLogicTM ION9000 series meter with RD192 display PowerLogicTM ION9000 RD192 remote display Main characteristics � PQ compliance reporting and basic PQ analysis: � Monitors and logs parameters according to IEC 61000-4-30 Class A international PQ standards (test methods as per IEC 62586-2). � High resolution waveform capture: triggered manually or by event. Captured waveforms available directly from the meter via SFTP in a COMTRADE format, and viewable in the meter's web interface. � Generates onboard PQ compliance reports accessible via onboard web pages: � Pass/fail report for IEEE 519 for voltage and current harmonic limits. � ITIC (CBEMA) and SEMI curves, with alarm categorization to support further analyses. � NEMA Motor Derating curve. � Harmonic analysis: � THD and TDD per phase, min/max, custom alarming. � Individual harmonic magnitudes and angles on voltage and current, up to the 63rd harmonic. � Disturbance detection and capture: sag/swell on any current and voltage channel, alarm on disturbance event, and waveform capture. � Patented Disturbance Direction Detection: provides indication of the captured disturbance occurring upstream or downstream of the meter; timestamped results provided in the event log, with degree of certainty of disturbance direction. � Transient detection and capture: events 20 microseconds or longer in duration on any voltage channel with alarm, event log, and waveform capture. � PowerLogic ION9000T also provides High-Speed Transient Capture (HSTC) of voltage events 100 nanoseconds or longer in duration and up to 10,000 V in magnitude with high-speed and disturbance waveform captures, as well as per-event statistics on each transient. � Metering precision: � IEC 61557-12 PMD/SD/K70/0.2 and PMD/SS/K70/0.2 3000m (Performance Measuring and Monitoring devices (PMD)). � Class 0.1S accuracy IEC 62053-22, ANSI C12.20 Class 0.1 (active energy). � Industry leading Class 0.5S accuracy for reactive energy (IEC 62053-24). � Cycle-by-cycle RMS measurements updated every � cycle. � Full `multi-utility' WAGES metering support. � Net metering. � Anti-tamper protection seals and hardware metrology lock. � Cybersecurity: � Security events logging with Syslog protocol support. � HTTPS and SFTP secure protocols. � Ability to enable or disable any communication port and any protocol per port. � Anti-tamper protection seals and hardware metrology lock. � User accounts with strong passwords. PowerLogicTM ION9000 front view PB115918 118 Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS PB115916 PB115919 PowerLogic ION9000 with panel mounting adapter PowerLogic ION9000 front with two option modules PowerLogic ION9000 bottom with two option modules � Used with Schneider Electric's advanced software tools, provides detailed PQ reporting across entire network: � EN 50160 compliance report. � IEEE 519 harmonic compliance report. � IEC 61000-4-30 report. � Power quality compliance summary. � Energy reports for consumption analysis and cost management. � WAGES dashboards and reports. � Display of waveforms and PQ data from all connected meters. � Onboard web-based waveform viewer. � EcoStruxure Power Events Analysis, including alarm management, sequence of events, and root cause analysis. � Data and event logging: � Onboard data and event logging. � 2 GB of standard non-volatile memory. � No data gaps due to network outages or server downtime. � Min/max log for standard values. � 100 user-definable data logs, recording up to 16 parameters at a 1/2 cycle or other user definable interval. � Continuous logging or snapshot, triggered by setpoint and stopped after defined duration. � Trend energy, demand and other measured parameters. � Forecasting via web pages: average, minimum and maximum for the next four hours and next four days. � Advanced time-of-use capability. � Security/event log: alarm conditions, metering configuration changes, power outages, firmware download, and user login/logout with timestamp. � Alarming and control: � 50+ definable alarms to log critical event data, trigger waveform recording, or perform control function. � Trigger on any condition, with 1/2-cycle and 1-second response time. � Combine alarms using Boolean logic enabling customization of alarms. � Alarm notification via email. � In conjunction with Schneider Electric's EcoStruxure software, alarms, software alarms, and alarm frequency are categorized and trended enabling sequence of events and root cause analyses. Usability � Auto-discovery using DPWS (Device Profile Web Services). � DHCP for automatic IP address configuration. � Full function web server enables simple web commissioning. � Free setup wizard simplifies meter configuration. � Front panel: � Easy to read color graphic display. � Simple and intuitive menu navigation with multiple language interface and support. � DIN rail mounting options. � Remote display option. � Pluggable connectors. � Low Voltage Current Sensors Input option. PB115920 Version: 1.0 - 27/08/2020 PLSED309005EN_06 (1) For 50 Hz line frequency; 17�s for 60 Hz line frequency. 119 PB115915 ADVANCED METERING PowerLogic ION9000 Harmonics display 120 FUNCTIONS AND CHARACTERISTICS � Flexible remote communications: � Multiple simultaneously operating communication ports and protocols allow interfacing with other automation systems, e.g. waveforms, alarms, billing data, etc. Data can be uploaded for viewing/analysis while other systems access real-time information. � Supports: Modbus, ION, DNP3, DLMS/COSEM, SNMP, and IEC 61850. � Dual port Ethernet: 2x 10/100BASE-TX; supports IPV4 and IPV6; daisychaining capability removes need for additional switches. � Create redundant network loop using Rapid Spanning Tree Protocol (RSTP) and managed Ethernet switches. � Secure web interface with HTTPS and TLS 1.2 with support for userprovided certificates. � Customize TCP/IP port numbers and enable/disable individual ports. � RS-485 2-wire connection, up to 115,200 baud, Modbus RTU, ION and DNP3 protocols. � Ethernet to serial gateway with Modbus Master functionality, connecting to 31 unit loads of downstream serial Modbus devices. Also supports Modbus Mastering over TCP/IP (Ethernet) network. � Full function web server with factory and customizable pages to access real-time and PQ compliance data. � Push historical data via email. � Advanced network security: Up to 50 configurable user accounts. � Time synchronization via: � Precision network time protocol (PTP) based on IEEE 1588 / IEC 61588. � GPS clock (RS-485) or IRIG-B (digital input) to �1 millisecond. � Network Time Protocol (NTP/SNTP). � Automatic time synchronization available through Schneider Electric software server. Adaptability � IONTM frameworks are customizable, scalable applications with objectoriented programming that compartmentalizes functions, and increases flexibility and adaptability. � Applications include: access and aggregate data from Modbus devices on serial port or across the network (Modbus TCP/IP), logging and/or processing data by totaling, unit conversion or other calculations, applying complex logic for alarming or control operations, data visualization via web pages. Standard meter I/O � 8 digital status/counter inputs with �1 millisecond timestamp. � 4 solid state digital outputs (Form A) for energy pulsing, interfacing with other systems or control. � 2 Form C relay outputs for control applications. Modular I/O options � Optional expansion modules. � Up to 4 modules per meter. Option modules include: � Digital module: � 6 digital status/counter inputs. � 2 Form C relay outputs, 250 V AC, 8 A. � Analog module: � 4 analog inputs (0-20 mA, 4-20 mA; 0-30 V). � 2 analog outputs (0-20 mA, 4-20 mA; 0-10 V) for interfacing with building management sensors and systems. Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED METERING ION9000 series FUNCTIONS AND CHARACTERISTICS Feature guide General Use on LV, MV, and HV systems Current accuracy: 0.1 % reading Voltage accuracy: 0.1 % reading Active energy accuracy: 0.1 Class Number of samples/cycle or sample frequency: 1024 High-Speed Transient Capture: 10 MHz (200 k for 50 Hz, 167 k for 60 Hz) Instantaneous rms values Current, voltage, frequency Active, reactive, apparent power: Total and per phase Power factor: Total and per phase Energy values Active, reactive, apparent energy Settable accumulation modes Demand values Current: Present and max. values Active, reactive, apparent power: Present and max. values Predicted active, reactive, apparent power Synchronization of the measurement window Setting of calculation mode: Block, sliding Power Quality measurements Harmonic distortion: Current and voltage Individual harmonics: via front panel and web page: 63 via EcoStruxureTM software: 511 Waveform capture Detection of voltage swells and sags Fast acquisition: 1/2 cycle data EN 50160 compliance checking Customizable data outputs (using logic and math functions) IEEE 519 compliance checking Data recording Min/max of instantaneous values Data logs Event logs Trending/forecasting SER (Sequence of event recording) Time stamping GPS synchronization (� 1ms) Memory: 2000 MB Display and I/O Front panel display, 2 options: 96 mm & 192 mm Pulse output: 2 Digital or analog inputs(max): 32 digital, 16 analog Digital or analog outputs (max, including pulse output): 4 digital, 10 relay, 8 analog Communication RS-485 port(s): 2 Ethernet port(s): 2x 10/100BASE-TX, RJ45 connector, CAT5/5e/6/6a cable Serial port protocols (Modbus, ION, DNP3, DLMS/COSEM) Ethernet port protocols (Modbus, ION, DNP3, DLMS/COSEM, IEC 61850) Ethernet gateway Alarm notification via email HTTP/HTTPS web server with waveform viewer SNMP with custom MIB and traps for alarms SMTP email PTP and NTP time synchronization SFTP file transfer ION9000 b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b ION9000T b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b Version: 1.0 - 27/08/2020 PLSED309005EN_06 121 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS ION9000 series Technical specifications Electrical characteristics Type of measurement Measurement accuracy Current & voltage Active Power Power factor Frequency Active energy Display refresh rate Input-voltage characteristics Input-current characteristics LV Input-current characteristics Power supply AC/DC Input/outputs Reactive Energy Specified accuracy voltage Impedance Specified accuracy frequency Limit range of operation - frequency Rated nominal current Specified accuracy current range Permissible overload Impedance Burden Input voltage range Minimum signal Withstand Input impedance Safety AC DC Ride-through time (Values for meters with no optional accessories) Burden Meter base Only Optional True rms to 1,024 samples per cycle High-speed transient detection, 10 MHz, 10 kV Class 0.1 as per IEC 61557-12 Class 0.1 as per IEC 61557-12 Class 0.5 as per IEC 61557-12 Class 0.02 as per IEC 61557-12 Class 0.1S IEC 62053-22 Class 0.1 IEC 61557-12 Class 0.1 ANSI C12.20 Class 0.5S IEC 62053-24 HMI display updated once per second; data refresh rate 1/2 cycle or 1 second 57 - 400 V L-N / 100 - 690 V L-L 5 MW per phase 42 to 69 Hz (50/60 Hz nominal) 20 to 450 Hz 1 A (0.1S), 5 A (0.1S); current class 2, 10, 20 A (0.1 ANSI) Starting Current: 1 mA (no accuracy) Accurate Range: 10 mA - 20 A 500 A rms for 1.0s 0.0003 W per phase 0.01 VA max at 5 A �5.5 V pk 1 mV 30 V pk continuous 200 k W For use with listed Energy Monitoring current transformers 90-480 V AC �10 % (50/60 Hz �10 %) 90-120 V AC �10% (400 Hz) 110-480 V DC �15 % 100 ms (5 cycles at 50/60 Hz) typ., 120 V AC 400 ms (20 cycles at 50/60 Hz) typ., 240 V AC 1,200 ms (60 cycles at 50/60 Hz) typ., 480 V AC Typical: 16.5 W / 38 VA at 480 V (50/60 Hz) Fully optioned: max. 40 W / 80 VA at 480 V (50/60 Hz). 8 digital inputs (30 V AC/60 V DC) 4 Form A (KY) solid state digital output (30 V AC/60 V DC, 75 mA) 2 Form C relays (8 A at 250 V AC, 5 A at 24 V DC) Digital - 6 digital inputs (30 V AC / 60 V DC) wetted + 2 Form C relay outputs (250 V AC, 8 A) Analog - 4 analog inputs (0-20 mA, 4-20 mA, 0-30 V DC) + 2 analog outputs (0-20 mA, 4-20 mA, 0-10 V DC). ION9000 b b b b b b b b b b b b b b b b b b 1 b 1 b 1 b 1 b 1 b b b b b b b ION9000T b b b b b b b b b b b b b b b b b b b b b b b b b 1 The LV Input-current option replaces standard CT inputs (1) Consult the ION7550 / ION7650 installation guide for complete specifications. (2) IEC 62051-22B with serial ports only. 122 Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS ION9000 series Mechanical characteristics Weight IP degree of protection Excellent quality Dimensions Panel mount DIN rail mount meter ION9000 DIN rail mount meter 1.5 kg b IO modules 0.140 kg Touchscreen display 0.300 kg IP 65, UL type 12: Panel mount and touchscreen display, front. b IP 30: Panel mount rear, DIN rail mount, I/O modules. ISO 9001 and ISO 14000 certified manufacturing. b 160 x 160 x 135.3 mm b 160 x 160 x 135.3 mm b Color remote 197 x 175 x 27.5 mm touchscreen b display (2 options) I/O modules 90.5 x 90.5 x 22 mm b Touchscreen 192 mm and 96 mm b display(s) Environmental conditions Operating temperature -25 to 70 �C b Remote Display Unit -25 to 60 �C b Storage temperature -40 to 85 �C b Humidity rating 5 to 95 % non-condensing b Installation category III b Operating altitude (maximum) 3,000 m above sea-level b Electromagnetic compatibility EMC standards IEC 62052-11, IEC 61326-1, IEC 61000-6-5 b Immunity to electrostatic discharge IEC 61000-4-2 b Immunity to radiated fields IEC 61000-4-3 b Immunity to fast transients IEC 61000-4-4 b Immunity to surges IEC 61000-4-5 b Immunity to conducted IEC 61000-4-6 b disturbances Immunity to power frequency IEC 61000-4-8 b magnetic fields Immunity to conducted CLC/TR 50579 b disturbances, 2-150kHz Immunity to voltage dips & IEC 61000-4-11 b interruptions Immunity to ring waves IEC 61000-4-12 b Conducted and radiated emissions EN 55011 and EN 55032 Class B, FCC part 15 Class B, ICES-003 Class B b Surge withstand Capability (SWC) IEEE/ANSI C37.90.1 b Safety Safety Construction IEC/EN 61010-1 ed.3, CAT III, 400 V L-N / 690 V L-L, UL 61010-1 ed.3 and CSA-C22.2 No. b 61010-1 ed.3, CAT III, 347 V L-N / 600 V L-L, IEC/EN 62052-31, protective class II. Communication Ethernet to serial line gateway Communicates directly with up to 31 serial devices. b Web server Customizable pages, new page creation capabilities, HTML/XML compatible. b Serial port RS-485 2x, Baud rates of 2,400 to 115,200, pluggable screw terminal connector. b Ethernet port(s) 2x 10/100BASE-TX, RJ45 connector, CAT5/5e/6/6a cable. b Protocol HTTPS, SFTP, SNMP, SMTP, DPWS, RSTP, PTP, NTP/SNTP, GPS, Syslog, DHCP, IPv4, IPv6. b Firmware characteristics High-speed data recording Down to 1/2 cycle interval recording, stores detailed characteristics of disturbances b or outages. Trigger recording by a user-defined setpoint, or from external equipment. Harmonic distortion Up to 63rd harmonic (511th via Schneider Electric EcoStruxure software) for all b voltage and current inputs. Sag/swell detection Analyze severity/potential impact of sags and swells: magnitude and duration data suitable for b plotting on voltage tolerance curves per phase triggers for waveform recording. ION9000T b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b Version: 1.0 - 27/08/2020 PLSED309005EN_06 123 ADVANCED METERING FUNCTIONS AND CHARACTERISTICS ION9000 series Firmware characteristics (cont.) ION9000 Disturbance direction detection Determine the location of a disturbance more quickly and accurately by determining the b direction of the disturbance relative to the meter. Results are captured in the event log, along with a timestamp and confidence level indicating level of certainty. Detection and capture of As short as 20 s at 50 Hz (17 s at 60 Hz) b transients High-speed transient capture Detection and capture of high-speed impulsive and oscillatory transients as short as 100 ns in b duration and up to 10 kV in magnitude. (PowerLogic ION9000T). Instantaneous High accuracy of standard speed (1s) and high-speed (1/2 cycle) measurements, b including true rms per phase and total for: voltage, current, active power (kW),reactive power (kvar), apparent power (kVA), power factor, frequency, voltage and current unbalance, phase reversal. Load profiling Channel assignments (1600 channels via 100 recorders) configurable for any b measurable parameter, including historical trend recording of energy, demand, voltage, current, power quality, or any measured parameter. Trigger recorders based on time interval, calendar schedule, alarm/event condition, or manually. Trend curves Historical trends and future forecasts to better manage demand, circuit loading, and other b parameters. Provides average, min, max, and standard deviation every hour for last 24 hours, every day for last month, every week for last 8 weeks and every month for last 12 months. Waveform captures Simultaneous capture of voltage and current channels, sub-cycle disturbance captures of b 180-cycles @ 1,024 samples/cycle to 7,200-cycles @ 16 sample/cycle, retriggerable. High-speed transient waveform captures Simultaneous capture of voltage channels, impulsive and oscillatory transient capture of up to 1-cycle @ 200 k samples per cycle (50 Hz) along with coincidence disturbance waveform capture (PowerLogic ION9000T). Alarms Threshold alarms: adjustable pickup and dropout setpoints and time delays, numerous activation b levels possible for a given type of alarm, user-defined or automatic alarm threshold settings, user- defined priority levels (optional automatic alarm setting). Advanced Time of Use (TOU) 4 seasons; 5 different day types: weekend, weekday, and holiday; up to 4 tariffs per day type. b Advanced network security Up to 50 users with unique access rights. Perform resets, time sync, or meter b configurations based on user privileges. Memory 2,000 MB. b Firmware update Update via the communication ports. b Display characteristics 96 mm pushbutton display 320 x 240 (1/4 VGA) color LCD, configurable screens, 5 buttons and 2 LED indicators b (alarm and meter status). 192 mm touchscreen display 800 x 480 pixels, 177.8 mm (7") Color LCD, +/- 85 degree view angle, sunlight readable, b dual capacitive touch, usable when wet or through Class 0 lineman gloves, impact resistant to 5 joules, IP65 rating. Languages English, French, Spanish, Russian, Portugese, German, Italian, Chinese. b Notations IEC, IEEE. b ION9000T b b b b b b b b b b b b b b b b b ION9000 Commercial reference numbers Comm ref number METSEION92030 METSEION92040 METSEION93030 METSEION93040 METSEION95030 METSEION95040 METSEPM89RD96 METSERD192 METSEPM89M2600 METSEPM89M0024 METSE9HWK METSE9CTHWK METSERD192HWK METSE9B2BMA METSE9HWKLVCS METSE9USBK METSE7X4MAK Description ION9000 meter, DIN mount, no display, hardware kit ION9000 meter, DIN mount, 192 mm display, B2B adapter, hardware kit ION9000 meter, LVCS, DIN mount, no display, hardware kit ION9000 meter, LVCS, DIN mount, 192 mm display, B2B adapter, hardware kit ION9000T meter, HSTC, DIN mount, no display, hardware kit ION9000T meter, HSTC, DIN mount, 192 mm display, B2B adapter, hardware kit Remote display, color LCD, 96 x 96 mm Remote display, color touchscreen, 192 x 192 mm I/O module, 2 relay outputs, 6 digital inputs I/O module, 2 analog outputs, 4 analog inputs ION9000 meter hardware kit � plugs, terminal guards, spare grounding screw, DIN clips ION9000 Current Input hardware kit - terminal screws, CT covers RD192 remote display hardware kit ION9000 B2B (back to back) mounting adapter ION9000 hardware kit for LVCS ION9000 USB cover hardware kit ION7X50 mounting adapter kit Contact your Schneider Electric representative for complete ordering information. 124 Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED METERING ION9000 series ION9000 meter dimensions DIMENSIONS AND CONNECTION ION9000 mounting template PB119714_m PB119707 PB120537 PB119712_m PB119705 ION9000 back-to-back (B2B) dimensions LVCS Input-current option ION9000 192 mm display dimensions ION9000 96 mm display dimensions Please refer to ION9000 Series Meter Installation Sheet for accurate and complete information on the installation of this product. Version: 1.0 - 27/08/2020 PLSED309005EN_06 125 PB119713_m PB119706 ADVANCED METERING ION9000 series ION9000 meter DIN rail dimensions FUNCTIONS AND CHARACTERISTICS ION7x50 mounting adapter dimensions PB119714 ION9000 LV Current Input wiring options PB120533 126 Version: 1.0 - 27/08/2020 PLSED309005EN_06 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS Advanced utility metering Power quality and revenue meters are designed for utility network monitoring, e.g. transmission and distribution network monitoring. Revenue and power quality meters designed for precision metering at key transmission network inter-ties, distribution substations and service entrances to optimise power reliability and energy efficiency in utility smart grids. � � PowerLogic ION7400 � � PowerLogic ION8650 � � PowerLogic ION8800 PB115152 PB107500 PE86176 METSEION7400 Version: 1.0 - 24/01/2020 PLSED309005EN_07 M8650A P880CA0A 127 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS ION7400 series Providing high accuracy and a wide range of features for transmission and distribution metering, the versatile PowerLogic ION7400 series advanced utility meter has the flexibility to change along with your needs. � Compact 3-phase, multifunction energy and power quality compliance � Flexible and modular installation with object-oriented intelligence � Accurate, precise, and highly adaptable metering Applications � Substation feeder metering � Revenue metering � Extensive power quality monitoring and cause analysis � End feeder line monitoring � Digital fault recording PB115152 128 METSEION7400 Version: 1.0 - 21/07/2020 PLSED309005EN_07 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic ION7400 series meters: � Transmission networks � Distribution network Benefits � Reduce operations costs � Improve power quality � Improve continuity of service Competitive advantages � Be able to use Power Monitoring Expert software for data analysis or share operation data with SCADA systems through multiple communication channels and protocols � Transformer/line loss compensation � Instrument transformer correction � Utilize disturbance direction detection to help locate fault Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � ANSI C12.20 � IEC 61557-12 � CLC/TTR50579 � IEC 61850 � EN 50160 � IEC 62052-11 � IEC 61000-4-7 � IEC 62053-22 � IEC 61000-4-15 � IEC 62053-23 � IEC 61000-4-30 � IEC 62586 � IEC 61010-1 � IEEE 519 � IEC 61326 Version: 1.0 - 21/07/2020 PLSED309005EN_07 129 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS PB115152 PB115161 PowerLogic ION7400 meter showing active alarms. PowerLogic ION7400 meter - rear view. PowerLogic ION7403 DIN rail mounted meter. 130 Applications and benefits � Maximize profits by providing the highest output possible with the least amount of risk to availability � Optimize availability and reliability of electrical systems and equipment � Monitor power quality (PQ) for compliance and to prevent problems � Meters fully supported by EcoStruxureTM Power Monitoring Expert and EcoStruxureTM Power SCADA Operation software Main characteristics � Precision metering: � IEC 61557-12 PMD/Sx/K70/0.2 3000m (performance measuring and monitoring functions) � IEC 62053-22 for active energy Class 0.2s accuracy and 0.5s accuracy, ANSI C12.20 Class 0.2 for active energy � IEC 62053-23 for reactive energy Class 2 accuracy and Class 3 � Cycle-by-cycle RMS measurements updated every � cycle � Full `multi-utility' WAGES metering support � Net metering � Anti-tamper protection seals � Test mode � PQ Compliance and basic PQ analysis. � Monitors and logs parameters in support of international PQ standards, � IEC 61000-4-30 Class S � IEC 61000-4-15 Flicker � IEC 62586 � EN 50160 � Generates onboard PQ compliance reports accessible via onboard web pages: � Basic event summary and pass/fail reports, such as EN 50160 for power � Frequency, supply voltage magnitude, supply voltage dips, short and long interruptions, temporary over voltages, voltage unbalance and harmonic voltage � ITIC (CBEMA) and SEMI curves, with alarm categorization to support further analyses � Basic meter provides EN 50160 but can be configured to provide IEEE 519 � Harmonic analysis: � THD on voltage and current, per phase, min/max, custom alarming � Individual harmonic magnitudes and angles on voltage and current, up to the 63rd harmonic (up to 127th via EcoStruxureTM software). � High resolution waveform capture: triggered manually or by alarm, captured waveforms available directly from the meter via FTP in a COMTRADE format or can be viewed via onboard webpages � Disturbance detection and capture: sag/swell on any current and voltage channel, alarm on disturbance event, waveform capture with pre-event information � Patented disturbance direction detection: provides indication of the captured disturbance occurring upstream or downstream of the meter; timestamped results provided in the event log, with degree of certainty of disturbance direction � Used with EcoStruxureTM Power Monitoring Expert software, provides detailed PQ reporting across entire network: � EN 50160 report � IEC 61000-4-30 report � PQ compliance summary � Display of waveforms and PQ data from all connected meters. Version: 1.0 - 21/07/2020 PLSED309005EN_07 PB115162_1 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS PB117739 PB113671 PB117743 PB115153 PowerLogic ION7400 with Harmonics display. PowerLogic remote display. PowerLogic I/O module. PowerLogic ION7400 meter with remote display. Version: 1.0 - 21/07/2020 PLSED309005EN_07 � Onboard data and event logging � 512 MB of standard non-volatile memory � No data gaps due to network outages or server downtime � Min/Max log for standard values � 50 user-definable data logs, recording up to 16 parameters on a cycle-by-cycle or other user definable interval � Continuous logging or `snapshot' triggered by setpoint and stopped after defined duration � Trend energy, demand and other measured parameters � Forecasting via web pages: average, minimum and maximum for the next four hours and next four days � Time-of-use in conjunction with EcoStruxureTM software � Event log: alarm conditions, metering configuration changes, and power outages, timestamped to 1 millisecond � Alarming and control. � 50+ definable alarms to log critical event data, trigger waveform recording, or perform control function � Trigger on any condition, with cycle-by-cycle and 1-second response time � Combine alarms using Boolean logic and to create alarm levels � Alarm notification via email text message � In conjunction with EcoStruxureTM Power Monitoring Expert, software alarms and alarm frequency are categorized and trended for easy evaluation of worsening/improving conditions � Excellent quality: ISO 9001 and ISO 14000 certified manufacturing Usability � Easy installation and setup � Panel and DIN rail mounting options, remote display option � Pluggable connectors � Free setup application simplifies meter configuration � Front panel � Easy to read color graphic display � Simple, intuitive menu navigation with multi-language (8) support � Optical port � 2 energy pulsing LEDs � Alt/Norm screens. � Flexible remote communications � Multiple simultaneously operating communication ports and protocols allow interfacing with other automation systems; (e.g. waveforms, alarms, billing data, etc.) can be uploaded for viewing/analysis while other systems access real-time information � Supports Modbus, ION, DNP3, IEC 61850, MV-90 � Dual port Ethernet: 10/100BASE-TX; daisy-chaining capability removes need for additional switches � Create redundant network loop using Rapid Spanning Tree Protocol (RSTP) and managed Ethernet switches � Customize TCP/IP port numbers enable/disable individual ports � RS-485 2-wire connection, up to 115200 baud, Modbus RTU and ION protocols, DNP3 is also supported via RS-485. 131 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS PB115159 PowerLogic ION7400 series meter with phasor display. Feature selection Commercial reference number METSEION7400 METSEION7410 Description ION7400 Panel mount meter (integrated display with optical port and 2 energy pulse LEDs) ION7400 Panel mount meter (integrated display with optical port and 2 energy pulse LEDs) 20-60 V DC control power METSEION7403 DIN rail mount - utility meter base METSEION7413 DIN rail mount - utility meter base 20-60 V DC control power Accessories Description METSEPM89RD96 Remote display, 3 metre cable, mounting hardware for 30 mm hole (nut & centering pin), mounting hardware for DIN96 cutout (92 x 92 mm) adapter plate METSEPM89M2600 Digital I/O module (6 digital inputs & 2 relay outputs) METSEPM89M0024 Analog I/O module (4 analog inputs & 2 analog outputs) METSECAB10 Display Cable, 10 m METSEPM8000SK Sealing kit � Flexible remote communications (cont'd) � Ethernet to serial gateway with Modbus Master functionality, connecting to 31 downstream serial Modbus devices. Also supports Modbus Mastering over TCP/IP (Ethernet) network. � Full function web server with factory and customizable pages to access realtime and PQ compliance data. � Push historical data via email. � Advanced security: Up to 16 configurable user accounts. � Time synchronization via: � GPS clock (RS-485) or IRIG-B (digital input) to +/- 1 millisecond. Also supports Network Time Protocol (NTP/SNTP) and time set function from EcoStruxure software server. Adaptability � IONTM frameworks allow customizable, scalable applications, object-oriented programming, compartmentalizes functions, and increases flexibility and adaptability. � Applications include: access and aggregate data from Modbus devices on serial port or across the network (Modbus TCP/IP), logging and/or processing data by totalizing, unit conversion or other calculations, applying complex logic for alarming or control operations, data visualization via web pages. Standard meter I/O � 3 digital status/counter inputs. � 1 KY (form A) energy pulse output for interfacing with other systems. Modular I/O options � Optional expansion modules (up to 4 per meter) add digital/analog I/O. Option modules include: � Digital module � 6 digital status/counter inputs. � 2 Form C relay outputs, 250 V, 8 A � Analog module. � 4 analog inputs (4-20 mA; 0-30 V) � 2 analog outputs (4-20 mA; 0-10 V) for interfacing with building management sensors and systems Standards � IEC 61000-4-30 � IEC 61000-4-7 � IEC 61000-4-15 � IEC 61326-1 � ANSI C12.20 � IEC 62052-11 � IEC 62053-22 � IEC 62053-23 � CLC/TR50579 Languages supported � English, French, Spanish, Chinese, Italian, German, Russian, Portuguese 132 Version: 1.0 - 21/07/2020 PLSED309005EN_07 PB113696 ADVANCED UTILITY METERING PowerLogicTM ION7400 bottom view DIN mounting. FUNCTIONS AND CHARACTERISTICS ION7400 series Feature guide General Use on LV and MV systems Current accuracy (5 A Nominal) Voltage accuracy (90-690 V AC L-L, 50, 60, 400 Hz) Active energy accuracy Reactive energy accuracy Number of samples/cycle or sample frequency Instantaneous rms values Current, voltage, frequency Active, reactive, apparent power Total and per phase Power factor Total and per phase Current measurement range (autoranging) Energy values Active, reactive, apparent energy Settable accumulation modes Demand values Current Present and max. values Active, reactive, apparent power Present and max. values Predicted active, reactive, apparent power Synchronisation of the measurement window Setting of calculation mode Block, sliding Power quality measurements Harmonic distortion Current and voltage Individual harmonics Via front panel and web page Via EcoStruxure software Waveform capture Detection of voltage swells and sags Flicker Fast acquisition 1/2 cycle data EN 50160 compliance checking Customizable data outputs (using logic and math functions) Data recording Min/max of instantaneous values Data logs Event logs Trending/forecasting SER (Sequence of event recording) Time stamping GPS synchronisation (+/- 1 ms) Memory (in Mbytes) Display and I/O Front panel display 89 mm TFT Wiring self-test Pulse output Digital Analog Digital or analog outputs (max, including pulse output) Communication RS-485 port 10/100BASE-TX Serial port (Modbus, ION, DNP3, DLMS/COSEM) Ethernet port (Modbus/TCP, ION TCP, DNP3 TCP, IEC 61850, DLMS/COSEM) USB port (mini type B) ANSI C12.19 Optical port All the communications ports may be used simultaneously ION7400 b 0.1 % reading 0.1 % reading 0.2 % 2 % 256 b b b 0.05 A - 10 A b b b b b b b b 63 127 b b b b b b b b b b b b b 512 b b 1 6 In / 2 Out 4 In / 2 Out 1 digital 8 relay 8 analog 1 2 b b b b Version: 1.0 - 21/07/2020 PLSED309005EN_07 133 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS ION7400 series Electrical characteristics Type of measurement Current & voltage Active Power Measurement accuracy Power factor Frequency Active energy Reactive Energy Data update rate Specified accuracy voltage Input-voltage characteristics Impedance Specified accuracy frequency - Frequency Limit range of operation frequency Input-current characteristics Rated nominal current Specified accuracy current range Power supply Permissible overload Impedance Burden AC/DC LV DC Ride-through time Burden Input/outputs Meter Base Only Optional Mechanical characteristics Weight IP degree of protection Panel mount model Dimensions DIN model Remote display IO modules Environmental conditions Operating temperature Remote Display Unit Storage temperature Humidity rating Installation category Operating altitude (maximum) ION7400 True rms to 256 samples per cycle Class 0.2 as per IEC 61557-12 Class 0.2 as per IEC 61557-12 Class 0.5 as per IEC 61557-12 Class 0.2 as per IEC 61557-12 Class 0.2S IEC 62053-22 (In=5A) Class 0.2 IEC 61557-12, ANSI C12.20 Class 0.2 Class 2 IEC 62053-23 1/2 cycle or 1 second 57 V L-N/100 V L-L to 400 V L-N/690 V L-L 5 MW per phase 42 to 69 Hz (50/60 Hz nominal) 20 Hz to 450 Hz 1 A (0.2S), 5 A (0.2S) , 10 A (0.2 ANSI) Starting Current: 5 mA Accurate Range: 50 mA - 10 A 200 A rms for 0.5s, non-recurring 0.0003 W per phase 0.024 VA at 10 A 90-415 V AC �10 % 16 VA at 230 V (50/60 Hz �10%), 110-300 V DC �10% 18 W (max) 20�60 V DC, �10 %,18 W (max) 100 ms (6 cycles at 60 Hz) min., any condition 200 ms (12 cycles at 60 Hz) typ., 120 V AC, 110-415 V DC 500 ms (30 cycles at 60 Hz) typ., 415 V AC Meter Only: 18 VA max at 415 V AC, 6W at 300 V DC Fully optioned meter: 36 VA max at 415 V AC, 17 W at 300 V DC. 3 form A digital inputs (30 V AC/60 V DC) 1 form A (KY) solid state digital output (30 V AC/60 V DC, 75 mA). Digital - 6 form A digital inputs (30 V AC / 60 V DC) wetted + 2 form C relay outputs (250 V AC / 30 V DC, 8 A at 250 V AC or 5 A at 24 V DC) Analog - 4 analog inputs (4-20 mA, 0-30 V DC) + 2 analog outputs (4-20 mA, 0-10 V DC). Integrated Display Model 0.710 kg (without option modules) DIN rail mounted Model 0.530 kg (without remore display or option modules) IO modules 0.140 kg Remote display 0.300 kg IP 54, UL type 12: Panel mount and Remote display, front. IP 30: Panel mount rear, DIN rail mount, I/O modules. 98 x 112 x 78.5 mm 90.5 x 90.5 x 90.8 mm 96 x 96 x 27 mm 90.5 x 90.5 x 22 mm -25 �C to 70 �C -25 �C to 60 �C -40 �C to 85 �C 5 % to 95 % non-condensing III 3000 m above sea level 134 Version: 1.0 - 21/07/2020 PLSED309005EN_07 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS ION7400 series Electromagnetic compatibility Product standards Immunity to electrostatic discharge Immunity to radiated fields Immunity to fast transients Immunity to surges Immunity to conducted disturbances Immunity to power frequency magnetic fields IEC 62052-11 and IEC 61326-1 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 Immunity to conducted disturbances, 2-150kHz CLC/TR 50579 Immunity to voltage dips & interruptions IEC 61000-4-11 Immunity to ring waves Conducted and radiated emissions Surge withstand Capability (SWC) IEC 61000-4-12 EN 55022, EN 55011, FCC part 15, ICES-003 IEEE C37.90.1 Safety Safety Construction IEC/EN 61010-1 ed.3, CAT III, 400 V L-N / 690 V L-L UL 61010-1 ed.3 and CSA-C22.2 No. 61010-1 ed.3, CAT III, 347 V L-N / 600 V L-L IEC/EN 62052-11, protective class II Communication Ethernet to serial line gateway Communicates directly with up to 32 unit load ION slave devices. Web server Customisable pages, new page creation capabilities, HTML/XML compatible. Serial port RS 485 Baud rates of 2400 to 115200, pluggable screw terminal connector. Ethernet port(s) USB port 2 x 10/100BASE-TX, RJ45 connector (UTP). Virtual serial port supports USB 3.0, 2.0, 1.1 using ION protocol. Protocol Firmware characteristics High-speed data recording Modbus, ION, DNP3, IEC 61850, MV-90, DLMS/COSEM, HTTP, FTP, SNMP, SMTP, DPWS, RSTP, NTP, SNTP, GPS protocols. Down to 1/2 cycle interval burst recording, stores detailed characteristics of disturbances or outages. Trigger recording by a user-defined setpoint, or from external equipment. Harmonic distortion Up to 63rd harmonic (via EcoStruxureTM software) for all voltage and current inputs. Sag/swell detection Disturbance direction detection Instantaneous Load profiling Trend curves Waveform captures Alarms Analyse severity/potential impact of sags and swells: magnitude and duration data suitable for plotting on voltage tolerance curves per phase triggers for waveform recording, control. Determine the location of a disturbance more quickly and accurately by determining the direction of the disturbance relative to the meter. Analysis results are captured in the event log, along with a timestamp and confidence level indicating level of certainty. High accuracy of standard speed (1s) and high-speed (1/2 cycle) measurements, including true rms per phase and total for: voltage, current, active power (kW),reactive power (kvar), apparent power (kVA), power factor, frequency, voltage and current unbalance, phase reversal. Channel assignments (800 channels via 50 data recorders) configurable for any measurable parameter, including historical trend recording of energy, demand, voltage, current, power quality, or any measured parameter. Trigger recorders based on time interval, calendar schedule, alarm/event condition, or manually. Historical trends and future forecasts to better manage demand, circuit loading, and other parameters. Provides average, min, max and standard deviation every hour for last 24 hours, every day for last month, every week for last 8 weeks and every month for last 12 months. Simultaneous capture of all voltage and current channels sub-cycle disturbance capture, maximum cycles is 100,000 (16 samples/cycle x 96 cycles, 10 MB memory), max 256 samples/cycle. Threshold alarms: adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm, user-defined or automatic alarm threshold settings, user-defined priority levels (optional automatic alarm setting). All the communication ports may be used simultaneously. Version: 1.0 - 21/07/2020 PLSED309005EN_07 135 PB115156 PB115154 PB115155 ADVANCED UTILITY METERING ION7400 meter parts descriptions 136 DIMENSIONS AND CONNECTION A Voltage inputs B Control power C Digital inputs D Revenue lock LED E Status LED (2 green/red) F Revenue lock switch G Digital output H Sealing gasket I Infrared energy pulsing LED J Energy pulsing LED K RS-485 L Current inputs M Ethernet (2) N Date/time O Indicator icons P Display Q Navigation icons R Navigation buttons S Home button T Alarm LED (red) U USB ports cover V Watt energy pulsing LED W Watt infrared energy pulsing LED X VAR infrared energy pulsing LED Y VAR energy pulsing LED Z Optical port Version: 1.0 - 21/07/2020 PLSED309005EN_07 PB115157_m ADVANCED UTILITY METERING ION7400 meter dimensions DIMENSIONS AND CONNECTION ION7400 panel cutout dimensions PB115158 For further details please see appropriate Schneider Electric Installation Guide for this product. Version: 1.0 - 21/07/2020 PLSED309005EN_07 137 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS ION8650 series Providing high accuracy and a wide range of features for transmission and distribution metering, the PowerLogic ION8650 advanced revenue and power quality meter has the flexibility to change along with your needs. The meter provides the tools necessary to: � Manage energy procurement and supply contracts � Perform network capacity planning and stability analysis � Monitor power quality compliance, supply agreements, and regulatory requirements Applications � Transmission and distribution metering � Revenue metering � Extensive power quality monitoring and analysis � Power quality compliance monitoring � Digital fault recording � Instrument transformer correction PB107500 138 M8650A Version: 1.0 - 24/01/2020 PLSED309005EN_07 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic ION8650 series meters: � Transmission networks � Distribution network Benefits � Reduce operations costs � Improve power quality � Improve continuity of service Competitive advantages � Be integrated into existing wholesale settlement system � Be able to use Power Monitoring Expert software for data analysis or share operation data with SCADA systems through multiple communication channels and protocols � Transformer/line loss compensation � Instrument transformer correction Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC 62053-22/23 � IEC 61000-4-4 � IEC 61000-4-30 � IEC 61000-4-5 � EN 50160 � IEC 61000-4-6 � IEC 61000-4-7 � IEC 61000-4-12 � IEC 61000-4-15 � CISPR 22 � IEEE 1159 � IEC 62052-11 � IEEE 519 � IEC 60950 � IEC 61000-4-2 � ANSI C12.20 � IEC 61000-4-3 Version: 1.0 - 24/01/2020 PLSED309005EN_07 139 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS PB107500 PowerLogic ION8650 socket meter Feature selection Commercial reference number ION8650 meters S8650A ION8650A S8650B ION8650B S8650C ION8650C 140 Main characteristics Used to monitor electric energy provider networks, service entrances and substations, PowerLogic ION8650 meters are ideal for independent power producers and cogeneration applications that need to accurately measure energy bi-directionally in both generation and stand-by modes. These meters give utilities the tools to manage complex energy supply contracts that include commitments to power quality. Integrate them with our EcoStruxureTM Power Monitoring operations software or other energy management and SCADA systems through multiple communication channels and protocols, including Itron MV-90, Modbus, DNP, DLMS, IEC 61850 Ed. 3. Applications � Revenue metering. � Cogeneration and IPP monitoring. � Compliance monitoring. � Power quality analysis. � Demand and power factor control. � Load curtailment. � Equipment monitoring and control. � Energy pulsing and totalisation. � Instrument transformer correction. � Outage Notification Main characteristics � ANSI Class 0.1 and IEC 62053-22/23 Class 0.2 S metering �� For interconnection points on medium, high, and ultra-high voltage networks; twice as accurate as current IEC and meets ANSI Class standards over all conditions and including single wide range current measurement. � Power quality compliance monitoring �� Monitor compliance with international quality-of-supply standards (IEC 61000-4-30 Ed. 3 Class A/S, EN 50160 Ed. 4, IEC 61000-4-7, IEC 61000-415, IEEE 1159, IEEE 519). Also detects disturbance direction. � Digital fault recording �� Simultaneous capture of voltage and current channels for sub-cycle disturbance. � Complete communications �� Multi-port, multi-protocol ports including serial, infrared, modem and ethernet. Simultaneously supports multiple industry standard protocols including: Itron MV-90, Modbus, Modbus Master, DLMS, DNP 3.0 and IEC 61850 Ed. 2. Cell modem option using CDMA or LTE. � Multiple tariffs and time-of-use �� Apply tariffs, seasonal rate schedules to measure energy and demand values for time periods with specific billing requirements. � Multiple setpoints for alarm and functions �� Use up to 65 setpoints for single/multi-condition alarms and I/O functions with response times down to 1/2 cycle. � Multiple setpoints for alarm and functions �� Use up to 65 setpoints. � Instrument transformer correction �� Save money and improve accuracy by correcting for less accurate transformers. � Alarm notification via email �� High-priority alarms, data logs sent directly to the user's PC. Instant notification of power quality events by email. � Cyber security enhancements �� Assign communication admin rights to selected user; prevention measures ensure no loss of security logs; support syslog for external security. Version: 1.0 - 24/01/2020 PLSED309005EN_07 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS PE86302-95 PowerLogic ION8650 switchboard meter. 1 Terminals 2 Optical port 3 Main display status bar 4 Watt LED 5 Navigation, ALT/Enter buttons 6 VAR LED 7 Nameplate label 8 Demand reset switch Disturbance waveform capture and power quality report Selection guide ION8650 ION8650 ION8650 A B C General Use on LV, MV and HV systems b b b Current accuracy Voltage accuracy Power accuracy Samples/cycle Instantaneous values 0.1 % 0.1 % 0.1 % 1024 0.1 % 0.1 % 0.1 % 1024 0.1 % 0.1 % 0.1 % 1024 Current, voltage, frequency b b b Active, reactive, apparent power Total & per phase b b b Power factor Total & per phase b b b Current measurement range Energy values 0 A - 20 A 0 A - 20 A 0 A - 20 A Active, reactive, apparent energy b b b Settable accumulation modes b b b Demand values Current Present & max values b b b Active, reactive, apparent power Present & max values b b b Predicted active, reactive, apparent power b b b Synchronisation of the measurement window b b b Demand modes: Block (sliding), thermal (exponential) b b b Power quality measurements Harmonic distortion Current & voltage b b b Individual harmonics Via front panel Waveform / transient capture Harmonics: magnitude, phase, and interharmonics Detection of voltage sags and swells 63 63 31 b / b - / b - / - 50 40 - b b b IEC 61000-4-30 class A / S IEC 61000-4-15 (Flicker) High speed data recording (down to 10 ms) EN 50160 compliance reporting Programmable (logic and math functions) A S - b b - b b - b b - b b b Data recording Onboard Memory (in Mbytes) Revenue logs 128 64 32 b b b Event logs b b b Historical logs b b b Harmonics logs b b b Sag/swell logs b b b Transient logs Time stamping to 1 ms b - - b b b GPS synchronisation (IRIG-B standard) b b b Display and I/O Front panel display b b b Wiring self-test (requires PowerLogic ION Setup) b b b Pulse output (front panel LED) 2 2 2 Digital or analog inputsg (max) 11 11 11 Digital or analog outputsg (max, including pulse output) 16 16 16 Communication Infrared port 1 RS-485 / RS-232 port 1 RS-485 port 1 Ethernet port (Modbus/TCP/IP protocol) with gateway 1 Internal modem with gateway (ModemGate) 1 HTML web page server b 1 1 1 1ggg 1 1ggg 1 1ggg 1 1ggg b b IRIG-B port (unmodulated IRIG B00x time format) Modbus TCP Master / Slave (Ethernet port) Modbus RTU Master / Slave (Serial ports) DNP 3.0 through serial, modem, and I/R ports 1 b / b b / b b 1 b / b b / b b 1 - / b - / b b Cell modem option (CDMA/LTE) b b b DLMS COSEM through serial, Ethernet and optical ports for all variants b b b g With optional I/O Expander. gg For 9S, and 36S only. For 35S system up to 480 V L-L. ggg C model limited to IR + 2 other ports at one time. Ports can be enabled/disabled by user. Version: 1.0 - 24/01/2020 PLSED309005EN_07 141 PE86002 PE86041 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS PowerLogic ION8650 front panel harmonic display. ION8650 front panel phasor display and table. Electrical characteristics Type of measurement True rms 1024 samples per cycle Current and voltage 0.1 % Reading Power 0.1 % Measurement accuracy Frequency Power factor �0.001 Hz 0.1 % Energy 0.1 %, twice as accurate as ANSI Class 0.2 and IEC 62053-22/23 (0,2S) Data update rate 0.5 cycle or 1 second (depending on value) Nominal voltage Input-voltage Maximum voltage characteristicsg Impedance Inputs 57 V to 277 V L-N rms 100 V to 480 V L-L rms (35S) 347 V L-N rms, 600 V L-L rms (9S) 5 MW /phase (phase-Vref/Ground) V1, V2, V3, VREF Rated nominal/current 1A, 2 A, 5 A and/or 10 A (Class 1/2/10/20) class Accuracy range 0.01 - 20 A (standard range) Input-current characteristics Measurement range Permissible overload 0.001 - 24 A 500 A rms for 1 second, non-recurring Burden per phase Standard power supply, blade powered Socket: Typical: 3 W, 8 VA/phase, 3-phase operation; Maximum: 4 W, 11 VA/phase, 3-phase operation Switchboard: 0.05 V A at 1 A (0.05 max) 120-277 V L-N RMS (-15 %/+20 %) 47-63 Hz or 120-480 V L-L RMS (-15 %/+20 %) 47-63 Hz (35S) Auxiliary powered low AC: 65-120 (+/- 15 %) VLN RMS, 47-63 Hz voltage DC: 80-160 (+/- 20 %) VDC Power supply Auxiliary powered high AC: 160-277 (+/- 20 %) V L-N RMS, 47-63 Hz voltage DC: 200-300 (+/- 20 %) V DC Ride-through time, (Standard power supply) Socket: min guaranteed: 6 cycles at nominal frequency (minimun 50 Hz), at 120 V L-N rms (208 V L-L rms) 3-phase operation Switchboard: min guaranteed: 6 cycles at nominal frequency (minimun 50 Hz), at 120 V L-N rms (208 V L-L rms) 3-phase operation Input/outputsgg Digital outputs 4 (Form C) Solid state relays (130 V AC/ 200 V DC) 50 mA AC/DC, 1 (Form A) output Digital inputs upto 3 Self-excited, dry contact sensing inputs Mechanical characteristics Weight 7.0 kg IP degree of protection Socket Switchboard Front IP65, back IP51 Front IP50, back IP30 Dimensions Socket 178 x 237 mm Switchboard 285 x 228 x 163 mm Environmental conditions Operating temperature -40 �C to 85 �C Display operating range -40 �C to 70 �C Storage temperature -40 �C to 85 �C Humidity rating 5 % to 95 % RH non-condensing Pollution degree 2 Installation category Cat III Dielectric withstand 2.5 kV Electromagnetic compatibility Electrostatic discharge IEC 61000-4-2 Immunity to radiated fields IEC 61000-4-3 Immunity to fast transients IEC 61000-4-4 Immunity to surge IEC 61000-4-5 Immunity conducted IEC 61000-4-6 Damped oscillatory waves immunity IEC 61000-4-12 Conducted and radiated emissions CISPR 22 (class B) Safety Europe As per IEC 62052-11 North America As per ANSI C12.1 g Specifications are limited by the operating range of the power supply if a non-aux power supply is used. gg More input and output selections available via optional I/O expander. PE86042 142 Version: 1.0 - 24/01/2020 PLSED309005EN_07 PB117744 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS Example embedded webserver page (WebMeter) showing realtime values. Communication RS-232 / RS-485 port (COM1) User-selectable RS-232 or RS-485. 300 - 115,200 baud (RS-485 limited to 57,600 bps); protocols: ION, Modbus/RTU/Mastering, DLMS, DNP 3.0, GPSTRUETIME/DATUM. Internal modem port (COM2) Cell modem option (CDMA/LTE) ANSI 12.18 Type II optical port (COM3) RS-485 port (COM4) Ethernet port EtherGate ModemGate Firmware characteristics High-speed data recording 300-57,600 bps CDMA2000 1xRTT / EV-DO Rev A (backwards compatible to EVDO Rev. 0 and CDMA 1x networks) 800/1900 MHz. MTSMC-LVW3 / LTE FDD Cat 1, 3GPP release 9 compliant, 4G: 1900 (B2) / 700 (B13) / AWS 1700 (B4) Up to 57,600 bps Up to 57,600 baud, Modbus, direct connection to a PC or modem 10/100BASE-T, RJ45 connector, protocols: DNP, ION, Modbus/TCP/Mastering, IEC 61850 Ed. 2 or 100BASE-FX multimode, male ST connectors, DLMS Up to 31 slave devices via serial ports Up to 31 slave devices Up to 1/2-cycle interval burst recording, stores detailed characteristics of disturbances or outages. Trigger recording by a user-defined setpoint, or from external equipment. Harmonic distortion Up to 63rd harmonic for all voltage and current inputs Dip/swell detection Instantaneous Analyse severity/potential impact of sags and swells: �� magnitude and duration data suitable for plotting on voltage tolerance curves �� per phase triggers for waveform recording or control operations High accuracy measurements with 1s or 1/2 cycle update rate for: �� voltage and current �� active power (kW) and reactive power (kVAR) �� apparent power (kVA) �� power factor and frequency �� voltage and current unbalance �� phase reversal Load profiling Channel assignments are user configurable: �� 800 channels via 50 data recorders (feature set A), �� 720 channels via 45 data recorders (feature set B), �� 80 channels via 5 data recorders (feature set C). Configure for historical trend recording of energy, demand, voltage, current, power quality, other measured parameters. Recorders can trigger on time interval basis, calendar schedule, alarm/event condition, manually. Waveform captures Simultaneous capture of all voltage and current channels �� sub-cycle disturbance capture (16 to 1024 samples/cycle) Alarms Advanced security Transformer correction Memory Firmware update Display characteristics Type Backlight Languages Threshold alarms: �� adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm �� user-defined priority levels �� boolean combination of alarms Up to 50 users with unique access rights. Perform resets, time syncs, or meter configurations based on user privileges. Correct for phase / magnitude inaccuracies in current transformers (CTs), potential transformers (PTs) 128 MB (A), 64 MB (B), 32 MB (C) Update via the communication ports FSTN transreflective LCD LED English Version: 1.0 - 24/01/2020 PLSED309005EN_07 143 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS PE86043-C PB107507 1 Model. 2 Feature set. 3 Form factor. 4 Current Inputs. 5 Voltage inputs. 6 Power supply. 7 System frequency. 8 Communications. 9 Input/output options. 10 Security. 11 Special order options. PowerLogic ION8650 meter with switchboard case Commercial reference numbers Item Code Description 1 Model 2 Feature Set M8650 Schneider Electric energy and power quality meter. A 128 MB Memory Class A power quality analysis, waveforms and transient capture with 1024 samples/cycle. B 64 MB memory, energy meter Class S EN 50160 Ed. 4 power quality monitoring. C 32 MB memory, basic tariff/energy metering (5 data recorders, 80 channels). 3 Form Factor (1) 0 1 Form 9S/29S/36S Base, 57-277 V L-N (autoranging) 3-Element, 4-Wire / 2 1/2-Element, 4-Wire Form 35S Base - 120-480 V L-L (autoranging) 2-Element, 3-Wire 4 7 4 Current Inputs C 5 Voltage Inputs 0 Form 9/29/35/36S FT21 Switchboard (meter + case) with break out panel Form 9/29/35/36S FT21 Switchboard (meter + case) with break out cable 1, 2 or 5 A nominal, 20 A full scale (24 A fault capture, start at 0.001 A) Standard (see Form Factor above) 6 Power Supplyg E H Form 9/29/35/36S, (socket) and Form 9, 36 (FT21 switchboard): 120-277 V AC. Form 35S (socket) and Form 35 (FT21 switchboard): 120-480 V AC. Powered from the meter's voltage connections. Auxiliary Power Pigtail: 65-120 V AC or 80-160 V DC (power from external source) J Auxiliary Power Pigtail: 160-277 V AC or 200-300 V DC (power from external source) K Auxiliary Power Pigtail: 65-120 V AC, 80-160 V DC (power from external source), Universal Socket Style L Auxiliary Power Pigtail: 160-277 V AC, 200-350 V DC (power from external source), Universal Socket Style 7 System Frequency 5 Calibrated for 50 Hz systems. 6 Calibrated for 60 Hz systems. 8 Communications A 0 Infrared optical port, RS-232/RS-485 port, RS-485 port C 7 Infrared optical port, Ethernet (10/100BASE-T), RS-232/485 port, RS-485 port (note: in addition to infrared optical port, Feature Set C can use any two ports (configurable)), 56 k universal internal modem (RJ11) E 1 Infrared optical port, Ethernet (10/100BASE-T), RS 232/485 port, RS-485 port (note: in addition to infrared optical port, Feature Set C can use any two ports (configurable)) F 1 Infrared Optical port, Ethernet (100BASE-FX multi-mode) with male ST connectors (available on socket meters only, Forms 0 & 1 above. I/O card not available if this option is ordered.) RS-232/485 port, RS-485 port (Note: in addition to Infrared Optical port Feature Set C can use any two ports (configurable)) M 1 Infrared optical port, RS-232/485 port, RS-485 port (note: in addition to infrared optical port, Feature Set C can use any two ports (configurable)), 56 k universal internal modem (RJ11). S 1 9 Onboard I/O A B C 10 Security 0 1 3 4 7 8 11 Special Order A Infrared optical port, Ethernet (10 BASE-T), RS-232/485 port, RS-485 port (note: in addition to infrared optical port, Feature Set C can use any two ports (configurable)), Verizon 4G LTE cell modem. None. 4 Form C digital outputs, 3 Form A digital inputs. 4 Form C digital outputs, 1 Form A digital output, 1 digital input. Password protected no security lock. Password protected with security lock enabled RMICAN (Measurement Canada approved) RMICAN-SEAL (Measurement Canada approved, and factory sealed) Password protected, no security lock (US only) Password protected with security lock enabled (US only) None gSpecifications are limited by the operating range of the power supply if a non-aux power supply is used. 144 Version: 1.0 - 24/01/2020 PLSED309005EN_07 PE86044_1 PE86131 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS Example order code. Use this group of codes when ordering the I/O Expander. 1 Digital / Analog I/O. 2 I/O option. 3 Cable option. Commercial reference numbers (cont.) I/O Expander Digital/Analog I/O P850E Schneider Electric I/O Expander for ION8600 meters: Inputs and Outputs for energy pulsing, control, energy counting, status monitoring, and analog interface to SCADA. I/O option Cable A External I/O box with 8 digital inputs and 8 digital outputs (4 Form A, 4 Form C) B External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (0 to 20 mA) C External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (-1 mA to 1 mA) D External I/O box with 8 digital inputs and 4 digital outputs (4 Form C) and 4 analog outputs (two -1 to 1 mA, and two 0 to 20 mA outputs) 0 No cable - cables for the I/O box are no ordered as a separate part number. Refer to commercial reference numbers: CBL- 8X00IOE5FT, CBL-8X00IOE15FT and CBL-8XX0-BOP-IOBOX under Connector cables, below. Comm. ref. no. A-BASE-ADAPTER-9 A-BASE-ADAPTER-35 OPTICAL-PROBE CBL-8X00BRKOUT CBL-8X00IOE5FT CBL-8X00IOE15FT A-base adapters Form 9S to Form 9A adapter Form 35S to Form 35A adapter Optical communication interface Optical communication interface Connector cables 1.5 m extension cable, mates with 24-pin male Molex connector from the meter to the 24-pin Molex connector on the I/O expander box (not for use with breakout panel E8, F8 & G8 form factors) 44.57 m extension cable, mates with 24-pin male Molex connector from the meter to the 24-pin Molex connector on the I/O expander box (not for use with breakout panel E8, F8 & G8 form factors) 44.57 m extension cable, mates with 24-pin male Molex connector from the meter to the 24-pin female Molex connector on the I/O Expander box (not for use with breakout panel E8, F8 & G8 form factors) CBL-8XX0-BOP-IOBOX 1.8 m connector cable, 24-pin male to 14-pin male Molex connector for connecting an ION8000 Series meter with breakout panel to an I/O Expander Box Version: 1.0 - 24/01/2020 PLSED309005EN_07 145 PE86303_m PE86304_m ADVANCED UTILITY METERING ION8650 socket dimensions ION8650 switchboard dimensions I/O Expander dimensions DIMENSIONS AND CONNECTION PE86305_m PE86306_m PE86307 PE86308 146 Version: 1.0 - 24/01/2020 PLSED309005EN_07 PE86052 ADVANCED UTILITY METERING ION8650 suggested switchboard mounting dimensions DIMENSIONS AND CONNECTION ION8650 switchboard mounting PE86309 PE86310 Please see appropriate Installation Guide for these products for further details. Version: 1.0 - 24/01/2020 PLSED309005EN_07 147 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS ION8800 series Providing high accuracy and a wide range of features for transmission and distribution metering, the PowerLogic ION8800 advanced revenue and power quality meter has the flexibility to change along with your needs. The meter provides the tools necessary to: � Manage energy procurement and supply contracts � Perform network capacity planning and stability analysis � Monitor power quality compliance, supply agreements, and regulatory requirements Applications � Transmission and distribution metering � Revenue metering � Extensive power quality monitoring and analysis � Power quality compliance monitoring � Digital fault recording � Instrument transformer correction PE86176 148 P880CA0A Version: 1.0 - 24/01/2020 PLSED309005EN_07 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic ION8800 series meters: � Transmission networks � Distribution network Benefits � Reduce operations costs � Improve power quality � Improve continuity of service Competitive advantages � Integrated into existing wholesale settlement system � Able to use EcoStruxureTM software for data analysis or share operation data with SCADA systems through multiple communication channels and protocols � Transformer/line loss compensation � Instrument transformer correction Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC 62053-22/23 � IEC 61000-4-3 � IEC 61000-4-30 � IEC 61000-4-4 � EN 50160 � IEC 61000-4-5 � IEC 61000-4-7 � IEC 61000-4-6 � IEC 61000-4-15 � IEC 61000-4-12 � IEEE 1159 � CISPR 22 � IEEE 519 � IEC 62052-11 � IEC 61000-4-2 � IEC 60950 Version: 1.0 - 24/01/2020 PLSED309005EN_07 149 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS Main characteristics � IEC 19-inch rack mount design to DIN 43862 standard �� Use Essailec connectors with common measurement and energy pulsing pin-out to easily retrofit into existing systems. � Accurate metering �� Interconnection points on medium, high, and ultra-high voltage networks are in compliance with IEC 62053-22/23 Class 0,2S. � Power quality compliance monitoring �� Monitor compliance with international quality-of-supply standards (IEC 61000-4-30 Class A/S, EN50160, IEC 61000-4-7, IEC 61000-415, IEEE 1159, IEEE 519). � Power quality summary �� Consolidate power quality characteristics into easily viewable reports indices. � Digital fault recording �� Capture voltage and current channels simultaneously for sub-cycle disturbances. � Complete communications �� Use the IEC1107 optical port or the optional communications module that supports concurrent Ethernet, serial, and modem communications. � Multiple tariffs and time-of-use �� Apply tariffs and seasonal rate schedules to measure energy and demand values for time periods with specific billing requirements. � Alarms and I/O functions �� Use up to 65 setpoints for single/multi-condition alarms and I/O functions with response times down to 1/2 cycle. � Alarm notification via email �� High-priority alarms, data logs sent directly to the user's PC. Instant notification of power quality events by email. � Software integration �� Easily integrate the meter with EcoStruxureTM Power Monitoring Expert, EcoStruxureTM Power SCADA Operation, or other utility software; MV-90, Pacis and third-party SCADA packages. � Transformer/line loss compensation �� Compensate for system losses in real time directly in the meter. � Instrument transformer correction �� Save money and improve accuracy by correcting for less accurate transformers. 150 150 Version: 1.0 - 24/01/2020 PLSED309005EN_07 PLSED3090051E5N0 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS PE86001 PowerLogic ION8800 meter 1 Optional communications module. 2 Essailec connectors. 3 Internal modem. 4 Optional Ethernet communications. 5 Selectable RS-485 serial port. 6 Selectable RS-232 or RS-485 serial port. 7 Ground terminal. Display screen examples: KWh disk simulator, voltage harmonics histogram, phasor diagram, and name plate1. (1) ION8800A only. (2) ION8800B only. Selection guide General Use on LV, MV and HV systems Current accuracy Voltage accuracy Power accuracy Samples/cycle Instantaneous rms values Current, voltage, frequency (Class 0,2S) Active, reactive, apparent power Total and per phase Power factor Total and per phase Current measurement range Current measurement range Energy values Active, reactive, apparent energy Settable accumulation modes Demand values Current Active, reactive, apparent Predicted active, reactive, apparent Demand modes (block, sliding, thermal, predicted) Power quality measurements Detection of voltage dips (sags) and swells Symmetrical components: zero, positive, negative Transient detection, microseconds (50 Hz) Harmonics: individual, even, odd, total up to Harmonics: magnitude, phase and inter-harmonics EN 50160 compliance IEC 61000-4-30 class A IEC 61000-4-30 class S IEC 61000-4-15 (Flicker) Configurable for IEEE 519 - 1992, IEEE1159-1995 Programmable (logic and math functions) Data recording Min/max logging for any parameter Historical logs Maximum # of records Waveform logs Maximum # of records Timestamp resolution in seconds Setpoints, minimum response time Number of setpoints GPS time synchronisation (IRIG-B) Could add transient logs. COMTRADE fault records. User configurable log memory Display and I/O Front panel display Active/reactive energy pulser, LED and IEC 1107 style port Digital pulse outputs, optional Solid state Form A Digital pulse outputs Solid state Form C Alarm relay output Form C Digital inputs (optional) Communications RS-232/485 port RS-485 port Ethernet port IEC 1107 optical port Internal modem 3-port DNP 3.0 through serial, modem, Ethernet and I/R ports Modbus RTU master / slave (serial, modem and I/R ports) Modbus TCP master / slave (via Ethernet port) DLMS/COSEM RS-485 port or Ethernet Data transfer between Ethernet and RS-485 (EtherGate) Data transfer between internal modem, RS-485 (ModemGate) Alarms, single or multi-condition Alarm notification & logged data via email Embedded web server (WebMeter) ION8800A ION8800B b 0.1 % 0.1 % 0.2 % 1024 b b b 0.001 - 10 A 0.001 - 10 A b b b b b b 10 ms b 20 (1) 63rd 50th b b b (2) b b(1) b b 960(1) 800(2) 96 (1) 0.001 � cycle 65 b b 10 MB b b 8 4 1 3 1 1 1 1 1 b b / b b / b b b b b b b ION8800C b 0.1 % 0.1 % 0.2 % 1024 b b b 0.001 - 10 A 0.001 - 10 A b b b b b b 10 ms - 20 (1) 63rd 40th b b 80 64 0.001 � cycle 65 b b 10 MB b b 8 4 1 3 1 1 1 1 1 b - / b - / b b b b b b b PE86235 Version: 1.0 - 24/01/2020 PLSED309005EN_07 151 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS Part numbers Item 1 Model Code Description M8800 ION8800 IEC/DIN 43862 19" rack mount energy and power quality meter. A Class A power quality analysis, waveforms and transient capture with 1024 samples/cycle. 2 Feature Set B Energy meter Class S EN50160 power quality monitoring. C Basic tariff/energy revenue meter with sag/swell monitoring. 3 Memory/Form Factor 1 10 MB logging memory, Essailec connectors. 2 5 MB logging memory, Essailec connectors, with IEC61850 protocol 4 Current Inputs C (I1-I3): Configured for 5 A nominal, 10 A full scale, 14 A fault capture, 0.001 A starting current. E (I1-I3): Configured for 1 A nominal, 10 A full scale, 14 A fault capture, 0.001 A starting current. 5 Voltage Inputs 0 (V1-V3): Autoranging (57-288 VAC L-N or 99-500 VAC L-L) 6 Power Supply B Single phase power supply: 85-240 VAC �10% (47-63 Hz) or 110-270 VDC. 7 System Frequency 5 Calibrated for 50 Hz systems. 6 Calibrated for 60 Hz systems. Z0 No communications module - meter includes Base Onboard I/O and comms (see below for details). A0 Standard communications: 1 RS 232/RS-485 port, 1 RS-485 port (COM2) (1). Communications 8 module (field serviceable) C1 Standard communications plus 10BASE-T Ethernet (RJ45), 56k universal internal modem (RJ11). D1 Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ45) / 10Base-FL/100BASE-FX Ethernet Fiber, 56k universal internal modem (RJ11) E0 Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ45). F0 Standard communications plus 10BASE-T/100BASE-TX Ethernet (RJ45) / 10Base-FL/100BASE-FX (ST male Fiber Optic connection). M1 Standard communications plus 56k universal internal modem (RJ11). Onboard I/O and 9 communications (not field serviceable, part of base unit) A Base option AND 8 Form A digital outputs (2), 1 RS-485 (COM2) port (1). B Base Option AND 8 Form A digital outputs (2), 3 digital inputs (20-56 VDC/AC). C Base Option AND 8 Form A digital outputs (2), 3 digital inputs (80-280 VDC/AC). D Base Option AND 1 IRIG-B time sync port (2), 1 RS-485 port (COM2), 3 digital inputs (20-56 V DC/AC) (1). E Base Option AND 1 IRIG-B time sync port (2), 1 RS-485 port (COM2), 3 digital inputs (80-280 V DC/AC) (1). 10 Security 0 Password protected, no security lock. 1 Password protected with security lock enabled. 11 Special Order A None. C Tropicalisation treatment applied. Example product part number. 1 Model. 2 Feature set. 3 Memory / form factor. 4 Current Inputs. 5 Voltage inputs. 6 Power supply. 7 System frequency. 8 Communications. 9 Onboard inputs/outputs. 10 Security. 11 Special order. (1) Channel COM2 is available on the port at the back of the meter OR on the Comm Module (if installed). You must select which connectors your communications wiring is connected to during meter setup. (2) All Onboard I/O and Comms (Base Option) options include: 4 Form C solid-state digital outputs, 1 Form C mechanical relay output, one IEC 1107 optical communications port, two IEC1107 style optical pulsing ports. PE86006 152 Version: 1.0 - 24/01/2020 PLSED309005EN_07 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS ION8800 Accessories Ordering reference Communication Card for ION8800 P880CA0A Std. comms: 1 RS-232/RS-485 port, **1 RS-485 port (COM2) P880CA0C Std. comms: 1 RS-232/RS-485 port, **1 RS-485 port (COM2), tropicalisation treatment applied P880CC1A Std. comms AND 10/1000BASE-TX Ethernet (RJ45), 56k universal internal modem (RJ11) P880CC1C Std. comms AND 10/1000BASE-TX Ethernet (RJ45), 56k universal internal modem (RJ11), tropicalisation treatment applied P880CD1A P880CD1C P880CE0A Std. comms AND 10/1000BASE-TX Ethernet (RJ45) / 10/100BASE-FX Ethernet Fiber, 56k universal internal modem (RJ11) Std. comms AND 10/1000BASE-TX Ethernet (RJ45) / 10/100BASE-FX Ethernet Fiber, 56k universal internal modem (RJ11), tropicalisation treatment applied Std. comms AND 10/1000BASE-TX Ethernet (RJ45) P880CE0C Std. comms AND 10/1000BASE-TX Ethernet (RJ45), tropicalisation treatment applied P880CF0A P880CF0C P880CM1A Std. comms AND 10/1000BASE-TX Ethernet (RJ45) / 10/100BASE-FX (ST Fiber Optic connection) Std. comms AND 10/1000BASE-TX Ethernet (RJ45) / 10/100BASE-FX (ST Fiber Optic connection), tropicalisation treatment applied Std. comms AND 56k universal internal modem (RJ11) P880CM1C Std. comms AND 56k universal internal modem (RJ11), tropicalisation treatment applied Ordering reference ION8800 related items BATT-REPLACE-8XXX Replacement batteries for the ION8600 or ION8800, quantity 10 RACK-8800-RAW IEC/DIN 34862 19" Rack with female mating voltage/current and I/O blocks unassembled. IEC-OPTICAL-PROBE IEC 61107 compliant Optical Probe (DB-9) for use with ION8800 meters PE86007_C Optional ION8800 communications module Version: 1.0 - 24/01/2020 PLSED309005EN_07 153 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS ION8800 series Technical Specification Technical Specification Electrical characteristics Type of measurement Current and voltage Measurement accuracy Power Frequency Power factor Energy Data update rate Inputs Input-voltage Measurement range characteristics Dielectic withstand Impedance Rated nominals Input-current Permissible overload characteristics Impedance Burden AC DC Power supply Burden Ride-through time Dielectric withstand True rms 1024 samples per cycle 0.1 % 0.2 % �0.005 Hz 0.1% IEC 62053-22/23 Class 0.2 S � cycle or 1 second U1, U2, U3, Uref 57-288 L-N V AC rms (99-500 L-L V AC rms) 3320 V AC rms 5 MW /phase (phase-Uref/Ground) 5 A, 1 A, 2 A 200A rms for 0.5s, non-recurring (IEC 62053-22) 10 mW /phase 0.01VA per phase (1A), 0.25VA per phase (5A) 85 - 240 V AC (+/- 10 %), 47-63 Hz 110 - 270 V DC (+/- 10 %) Typical (without comm module): 13 VA, 8 W Typical (with comm module): 19 VA, 12 W Max (without comm module): 24 VA, 10 W Max (with comm module): 32 VA, 14 W Typical: 0.5 s to 5 s depending on configuration Min: 120 ms (6 cycles @ 50 Hz) 2000 V AC Mechanical alarm relay 1 Form C digital output (250 V AC / 125 V DC, 1A AC / 0.1 A DC max) Input/outputs Digital outputs (Form C) Digital outputs (Form A) 4 Solid state relay outputs (210 V AC / 250 V DC) 100 mA AC/DC 8 Solid state relay outputs (210 V AC / 250 V DC) 100 mA AC/DC Digital inputs 3 Solid state digital inputs (low-voltage inputs 15 to 75 V AC/DC; high-voltage inputs 75 to 280 V AC/DC; 3 mA max.) Pulse rate Mechanical characteristics Weight IP degree of protection (IEC60529) Dimensions Environmental conditions Mounting location Maximum altitude Limit range of operation Specified operating temperature Display operating range Storage temperature Humidity rating Pollution degree Installation category Electromagnetic compatibility Electrostatic discharge Immunity to radiated fields Immunity to fast transients Immunity to surge waves Conducted immunity Damped oscillatory waves immunity Conducted and radiated emissions Safety Europe International 20 Hz maximum 6.0 kg (6.5 kg with optional communications module) IP51 202.1 x 261.51 x 132.2 mm Indoor 2000 metres above sea-level -25 �C to 70 �C -10 �C to 45 �C (as per 62052-11) -10 �C to 60 �C -25 �C to 70 �C 5 to 95 % RH non-condensing 2 Power supply (II) Metering inputs (III) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-12 CISPR 22 (class B) As per IEC 62052-11 As per IEC 60950 154 Version: 1.0 - 24/01/2020 PLSED309005EN_07 PE86234 PE86233 ADVANCED UTILITY METERING FUNCTIONS AND CHARACTERISTICS Ports on the optional communications module. Example embedded page showing realtime values. Technical Specification Communication IEC 1107 optical port RS-485 port 2/4 wires, up to 19200 baud Up to 57600 baud, direct connection to a PC or modem, protocols: ION, Modbus RTU, Modbus Master, DNP 3.0, GPSTRUETIME/DATUM, DLMS/COSEM Communications module (optional) RS-232/485 port Internal modem port Ethernet port Fiber-optic Ethernet link EtherGate ModemGate Firmware characteristics 300 - 115,200 baud (RS-485 limited to 57,600 baud); protocols: same as RS-485 port 300 baud - 56000 baud, RJ11 connector 10/100BASE-TX, RJ45 connector, 100 m link; protocols: DNP TCP, ION, Modbus TCP, Modbus Master, DLMS/ COSEM, IEC 61850 10/100BASE-FX, ST connector, 1300 nm, FO multimode with gradient index 62.5/125 �m or 50/125 �m, 2000 m link; protocols: same as Ethernet port Communicates directly with up to 62 slave devices via available serial ports Communicates directly with up to 31 slave devices High-speed data recording Harmonic distortion Up to �-cycle interval burst recording, stores detailed characteristics of disturbances or outages Trigger recording by a user-defined setpoint, or from external equipment. Up to 63rd harmonic for all voltage and current inputs Dip/swell detection Analyse severity/potential impact of sags and swells: magnitude and duration data suitable for plotting on voltage tolerance curves per phase triggers for waveform recording or control operations Instantaneous Load profiling Modbus Master Waveform captures Alarms Advanced security Transformer correction Memory Firmware update Display characteristics Type Backlight Languages High accuracy measurements with 1s or 1/2 cycle update rate for: voltage and current active power (kW) and reactive power (kvar) apparent power (kVA) power factor and frequency voltage and current unbalance phase reversal Channel assignments (800 channels via 50 data recorders) are configurable for any measureable parameter, including historical trend recording of energy, demand, voltage, current, power quality, or any measured parameter Trigger recorders based on time interval, calendar schedule, alarm/event condition, or manually. Master up to 32 slave devices per serial channel and store their data at programmable intervals. Use this data to aggregate and sum energy values and perform complex totaling. Simultaneous capture of all voltage and current channels sub-cycle disturbance capture maximum cycles is 214,000 (16 samples/cycle x 96cycles, 10MB memory) 1024 samples/cycle Threshold alarms: adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm user-defined priority levels boolean combination of alarms possible Up to 50 users with unique access rights. Perform resets, time syncs, or meter configurations based on user privileges. Correct for phase / magnitude inaccuracies in current transformers (CTs), potential transformers (PTs) 5 -10 MB(specified at time of order) Update via the communication ports FSTN transreflective LCD LED English PE86002 Version: 1.0 - 24/01/2020 PLSED309005EN_07 155 PE86008 ADVANCED UTILITY METERING ION8800 dimensions ION8800 Essailec rack dimensions Rack mounting the ION8800 PE86009 DIMENSIONS AND CONNECTION PE86010 PE86011 PE86012 ION8800 communication module dimensions Please see the appropriate Installation Guide for accurate and complete information on the installation of this product. 156 Version: 1.0 - 24/01/2020 PLSED309005EN_07 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS Multi-circuit metering This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in both new build and retrofit and is used for critical power operations in data centres and energy management in buildings. The ideal solution for data centre managers, energy or facility managers, engineers and operational executives who are responsible for delivering power to critical applications. In corporate and hosted data centre facilities, this technology helps you plan and optimise the critical power infrastructure to meet the demands of continuous availability. � � PowerLogic BCPM � � EM4000 Series � � EM4800 � � EM4900 PB113665 PE86325 PB113664 BCPMA084S Version: 1.0 - 24/01/2020 PLSED309005EN_08 BCPMA042S BCPMA084S 157 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS PowerLogic BCPM The PowerLogic BCPM is a highly accurate, full-featured metering product designed for the unique, multi-circuit and minimal space requirements of a high performance power distribution unit (PDU) or remote power panel (RPP). It offers class 1 (1 %) power and energy system accuracy (including 50 A or 100 A CTs) on all branch channels. The BCPM monitors up to 84 branch circuits and the incoming power mains to provide information on a complete PDU. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Applications � Maximise uptime and avoid outages � Optimise existing infrastructure � Improve power distribution efficiency � Track usage and allocate energy costs � Enable accurate sub-metering PB113665 158 BCPMA084S Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic BCPM series meters: � Data centres � Buildings Benefits The flexible BCPM fits any PDU or RPP design and supports both new and retrofit installations. It has exceptional dynamic range and accuracy, and optional feature sets to meet the energy challenges of mission critical data centres. Competitive advantages � Fit any PDU or RPP design for both new and retrofit projects � Class 1.0 system accuracy � Ethernet communication Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � ANSI C12.1 � IEC 61010-1 � IEC 62053-21 Class 1 � UL508 Version: 1.0 - 24/01/2020 PLSED309005EN_08 159 PB113649 PB113647 PB113646 PB113645 PB113664 PE86281 MULTI-CIRCUIT METERING BCPM 160 PB113648 FUNCTIONS AND CHARACTERISTICS Main characteristics � Monitor up to 84 branch circuits with a single BCPM. � Ideal for installation in both new PDUs and retrofit projects � New installations: �� BCPM with solid core CTs monitors up to 84 branch circuits using 2 or 4 CT strips. Solid core CTs are rated to 100 A CTs and are mounted on strips to simplify installation. CT strips are available with 12, 18 or 21 CTs per strip on 18 mm spacings. 21 CT strips with 3/4in or 1in spacings are also available. � Retrofit projects: �� BCPMSC with split-core CTs is ideal for retrofits. Any number of split-core CTs, up to 84 maximum, can be installed with a single BCPM. Three sizes of CT are supported (50 A, 100 A, and 200 A) and all three CT sizes can be used on a single BCPM. Adapter boards with terminals for split-core CTs can be mounted using DIN-rail, Snaptrack or on a common mounting plate with the main board (42 ch Y63 models only). � IEC Class 1 metering accuracy �� Accurately monitor very low current levels, down to a quarter-Amp. �� Easily differentiate between the flow of low current and a trip where no current flows. � Class 1.0 system accuracy for Revenue Grade measurements �� Branch Power and Energy measurements fully meet ANSI and IEC class 1 accuracy requirements with 50 or 100 A CTs included. No need to de-rate meter branch accuracy to allow for CTs. Voltage and current measurement accuracy is 0.5 % and currents are measured down to 50mA. Easily differentiate between the flow of low current and a trip where no current flows. Class 1.0 system accuracy for Revenue Grade measurements �� Branch Power and Energy measurements fully meet ANSI and IEC class 1 accuracy require � Power quality: obtain basic power quality data thanks to the measurement of Total Harmonic Distortion percentages on voltages and current. (V L-L, V L-N, I L-N). � Designed to fit any PDU or RPP design �� Lowers your total installation costs as well as the cost per meter point by supporting both new and retrofit installations. � Communicates with your various systems: BCPMA, and BCPMSCA have a Modbus RTU connection BCPME, and BCPMSCE, have a serial connection for either Modbus RTU or BACnet MS/TP. And there is an ethernet connection for Modbus TCP, BACnet IP and SNMP at the same time. Allowing the concurrent use of an Energy Management System, a Building Management System and an IT system. � Compatible with PowerLogic power monitoring software �� Easily turn the large amount of data collected by the devices into useful decision-making information. � Flexible Configuration capability �� Set the ordering and orientation of CT strips, assign individual CT size and phases, support for 1, 2, and 3-pole breakers in any configuration. Version: 1.0 - 24/01/2020 PLSED309005EN_08 PE86167 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS BCPM PowerLogic BCPM 1 50-pin ribbon cable connectors (data acquisition board). 2 Auxiliary inputs. 3 Control (mains) power connection. 4 Control power fuse. 5 Alive LED. 6 Voltage taps. 7 Communications address DIP switches. 8 Communications settings DIP switch. 9 RS-485 2 connection. 10 RS-485 LEDs. Feature selection General Use on LV systems Power and energy measurements Mains Branch circuits Instantaneous rms values Voltage, frequency Current Active power Total and per phase Power factor Total and per phase Energy values Active energy Demand values Total active power Present and max. values Power quality measurements THD % (V L-L, V L-N, I L-N) Detection of over-voltage/under-voltage Sampling rate points per cycle Alarming Alarms Power supply AC version Communication RS-485 port Modbus RTU Modbus TCP BACnet IP BACnet MS/TP SNMP protocol Ethernet Port g1 Add E8951 Gateway BCPMA BCPME b b b b b b b b b b b b b b b b b b b b 2560 Hz b b 2560 Hz b b 90-277 V AC 100-277 V AC b b RTU b 1g b 1g b 1g b 1g b 1g b Version: 1.0 - 24/01/2020 PLSED309005EN_08 161 PE86168 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS BCPM Example BCPM with solid core CTs part number 1. Model 2. Feature set 3. CT spacing (solid core models only) 4. Number of circuits 5. Brand The PowerLogic BCPM uses .333 V AC output split-core CTs for the auxiliary inputs. These CTs are ordered separately from the BCPM. BCPM part numbers BCPM with solid core CTs Item Code Description 1 Model BCPM BCPM with solid core CTs. Highly accurate meter that monitors branch circuits and the incoming power mains and includes full alarming capabilities 2 Feature set Advanced - Monitors power & energy per A circuit & mains, Modbus RTU only (add E8951 for other protocols), Meter Main Board comes on an aluminum mounting plate Advanced, with Ethernet - Monitors power & E energy per circuit & mains, Meter Main Board is partially enclosed in a metal housing 0 3/4in (19 mm) CT spacing 3 CT spacing 1 1in (26 mm) CT spacing 2 18 mm CT spacing 24 24 circuits, (2) 12-CT strips (18 mm spacing only) 36 36 circuits, (2) 18-CT strips (18 mm spacing only) 4 Number of circuits 42 42 circuits, (2) 21-CT strips 48 48 circuits, (4) 12-CT strips (18 mm spacing only) 72 72 circuits, (4) 18-CT strips (18 mm spacing only) 84 84 circuits, (4) 21-CT strips 5 Brand S Schneider Electric PB113664 PB113665 * Quantity and style of CT strips and cables included varies by model 162 Version: 1.0 - 24/01/2020 PLSED309005EN_08 PB113735 PB113666 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS BCPM Example BCPMSC with split-core CTs part number. 1 Model. 2 Feature set. 3 Number of circuits. 4 Brand. BCPM part numbers (contd.) BCPM with split-core CTs BCPM with split-core CTs 1 Model BCPMSC BCPM with split-core CTs. Highly accurate meter that monitors branch circuits and the incoming power mains and includes full alarming capabilities Advanced - Monitors power and energy per A circuit and mains, Modbus RTU only (add E8951 for other protocols), Meter Main Board comes on an aluminum mounting plate 2 Feature set Intermediate - Monitors current per circuit, power and energy per mains, Modbus RTU B only (add E8951 for other protocols), Meter Main Board comes on an aluminum mounting plate Basic - Monitors current only per circuit and C mains, Modbus RTU only (add E8951 for other protocols), Meter Main Board comes on an aluminum mounting plate Advanced, with Ethernet - Monitors power & E energy per circuit & mains, Meter Main Board is enclosed in a metal housing 1 42 circuit main and adapter boards (no branch CTs or ribbon cables, order separately) 2 84 circuit main and adapter boards (no branch CTs or ribbon cables, order separately) Number of 3 circuits 30 30 split-core CTs (50 A) 42 42 split-core CTs (50 A) 60 60 split-core CTs (50 A) 84 84 split-core CTs (50 A) 42 circuits � main and adapter boards on Y63 single mounting plate (no branch CTs or ribbon, order separately) - Feature set A only 4 Brand S Schneider Electric *The BCPMSC models with 1, 2 or Y63 as the number of circuits DO NOT INCLUDE ANY branch CTs or ribbon cables (they include only the Main board and adapater board assemblies). These models are provided to allow users to order a specific combination of CT quantities, CT sizes, CT lead lengths and ribbon cable styles and lengths. The CTs and cables must be ordered separately. The PowerLogic BCPMSC uses .333 V AC output split-core CTs for the auxiliary inputs. These CTs are ordered separately from the BCPMSC. PB113730 Version: 1.0 - 24/01/2020 PLSED309005EN_08 163 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS PE86284 PB113650 BCPM Flat ribbon cable CBL016 Round ribbon cable CBL022 Cabling and connection Flat ribbon cables are recommended for use when the BCPM printed circuit board will be mounted inside of the PDU that is being monitored. Round ribbon cables are the prefered choice when the ribbon cable will be threaded through conduit. BCPM part numbers for solid and split-core CTs (contd.) BCPM with split-core CTs Commercial ref. no. Description BCPMA042S 42-circuit solid core power & energy meter, 100 A CTs (2 strips), 19 mm spacing BCPMA084S 84-circuit solid core power & energy meter, 100 A CTs (4 strips), 19 mm spacing BCPMA142S 42-circuit solid core power & energy meter, 100 A CTs (2 strips), 25 mm spacing BCPMA184S 84-circuit solid core power & energy meter, 100 A CTs (4 strips), 25 mm spacing BCPMA224S 24-circuit solid core power & energy meter, 100 A CTs (2 strips), 18 mm spacing BCPMA236S 36-circuit solid core power & energy meter, 100 A CTs (2 strips), 18 mm spacing BCPMA242S 42-circuit solid core power & energy meter, 100 A CTs (2 strips), 18 mm spacing BCPMA248S 48-circuit solid core power & energy meter, 100 A CTs (4 strips), 18 mm spacing BCPMA272S 72-circuit solid core power & energy meter, 100 A CTs (4 strips), 18 mm spacing BCPMA284S 84-circuit solid core power & energy meter, 100 A CTs (4 strips), 18 mm spacing BCPME042S 42-circuit solid core power & energy meter w/Ethernet, 100 A CTs (2 strips), 19 mm spacing BCPME084S 84-circuit solid core power & energy meter w/Ethernet, 100 A CTs (4 strips), 19 mm spacing BCPME142S 42-circuit solid core power & energy meter w/Ethernet, 100 A CTs (2 strips), 25 mm spacing BCPME184S 84-circuit solid core power & energy meter w/Ethernet, 100 A CTs (4 strips), 25 mm spacing BCPME224S 24-circuit solid core power & energy meter w/Ethernet, 100 A CTs (2 strips), 18 mm spacing BCPME236S 36-circuit solid core power & energy meter w/Ethernet, 100 A CTs (2 strips), 18 mm spacing BCPME242S 42-circuit solid core power & energy meter w/Ethernet, 100 A CTs (2 strips), 18 mm spacing BCPME248S 48-circuit solid core power & energy meter w/Ethernet, 100 A CTs (4 strips), 18 mm spacing BCPME272S 72-circuit solid core power & energy meter w/Ethernet, 100 A CTs (4 strips), 18 mm spacing BCPME284S 84-circuit solid core power & energy meter w/Ethernet, 100 A CTs (4 strips), 18 mm spacing 164 Version: 1.0 - 24/01/2020 PLSED309005EN_08 PB113651 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS BCPM BCPM part numbers for solid and split-core CTs (contd.) BCPM with split-core CTs Commercial ref. no. Description BCPMSCA1S BCPMSCxY63S 42-circuit split-core models come with the main board, (2) adapter boards and ribbon cables all mounted on a backplate, to simplify installation. LVCT00050S PowerLogicTM LVCT0xxxxS Split-core Low-voltage (1/3V) CTs for Aux inputs (Mains) are ideal for retrofit applications BCPMSCA1S 42-circuit split-core power and energy meter, CTs and cables sold separately BCPMSCA2S 84-circuit split-core power and energy meter, CTs and cables sold separately BCPMSCA30S 30-circuit split-core power and energy meter, (30) 50 A CTs & (2) 1.2 m cables BCPMSCA42S 42-circuit split-core power and energy meter, (42) 50 A CTs & (2) 1.2 m cables BCPMSCA60S 60-circuit split-core power and energy meter, (60) 50 A CTs & (4) 1.2 m cables BCPMSCAY63S 42-circuit split-core power and energy meter, all boards on backplate, CTs and cables sold separately BCPMSCA84S 84-circuit split-core power and energy meter, with (84) 50 A CTs & (4) 1.2 m cables BCPMSCE1S 42-circuit split-core power and energy meter w/Ethernet, CTs and cables sold separately BCPMSCE2S 84-circuit split-core power and energy meter w/Ethernet, CTs and cables sold separately BCPMSCE30S 30-circuit split-core power and energy meter w/Ethernet, (30) 50 A CTs & (2) 1.2 m cables BCPMSCE42S 42-circuit split-core power and energy meter w/Ethernet, (42) 50 A CTs & (2) 1.2 m cables BCPMSCE60S 60-circuit split-core power and energy meter w/Ethernet, (60) 50 A CTs & (4) 1.2 m cables BCPMSCE84S 84-circuit split-core power and energy meter w/Ethernet, (84) 50 A CTs & (4) 1.2 m cables The PowerLogicTM BCPM uses .333 V AC output split-core CTs for the auxiliary inputs. These CTs are ordered separately from the BCPM. PE86183 PB113652 PB113657 PB113658 LVCT20050S PowerLogicTM LVCT2xxxxS Low-voltage (1/3V) solid core CTs for Aux inputs (Mains) are ideal for panel builders (small, medium, large) Version: 1.0 - 24/01/2020 PLSED309005EN_08 165 MULTI-CIRCUIT METERING BCPM Commercial ref. no. BCPM split-core branch CTs and adapter boards BCPMSCADPBS BCPM adapter boards, quantity 2, for split-core BCPM BCPMSCCT0 BCPM 50 A split-core CTs, Quantity 6, 1.8 m lead lengths BCPMSCCT0R20 BCPM 50 A split-core CTs, quantity 6, 6 m lead lengths BCPMSCCT1 BCPM 100 A split-core CTs, Quantity 6, 1.8 m lead lengths BCPMSCCT1R20 BCPM 100 A split-core CTs, Quantity 6, 6 m lead lengths BCPMSCCT3 BCPM 200 A split-core CTs, Quantity 1, 1.8 m lead lengths BCPMSCCT3R20 BCPM 200 A split-core CTs, Quantity 1, 6 m lead lengths Commercial ref. no. Additional accessories for use with BCPM products BCPMCOVERS BCPM circuit board cover BCPMREPAIR CT repair kit for solid core BCPM (includes one CT) H6803R-0100 Additional 100 A split-core CT for use with solid core repair kit E8951 Modbus to BACnet protocol converter CBL016 Flat Ribbon cable (quantity 1) for BCPM, length = 1.2 m CBL017 Flat Ribbon cable (quantity 1) for BCPM, length = 1.5 m CBL018 Flat Ribbon cable (quantity 1) for BCPM, length = 1.8 m CBL020 Flat Ribbon cable (quantity 1) for BCPM, length = 3.0 m CBL021 Flat Ribbon cable (quantity 1) for BCPM, length = 6.1 m CBL022 Round Ribbon cable (quantity 1) for BCPM, length = 1.2 m CBL024 Round Ribbon cable (quantity 1) for BCPM, length = 6.1 m 1/3 V low-voltage Split-core CTs for Aux inputs (Mains) Commercial ref. no. Amperage rating Inside dimensions LVCT00050S 50 A 10 mm x 11 mm LVCT00101S 100 A 16 mm x 20 mm LVCT00202S 200 A 32 mm x 32 mm LVCT00102S 100 A 30 mm x 31 mm LVCT00202S 200 A 30 mm x 31 mm LVCT00302S 300 A 30 mm x 31 mm LVCT00403S 400 A 62 mm x 73 mm LVCT00603S 600 A 62 mm x 73 mm LVCT00803S 800 A 62 mm x 73 mm LVCT00804S 800 A 62 mm x 139 mm LVCT01004S 1000 A 62 mm x 139 mm LVCT01204S 1200 A 62 mm x 139 mm LVCT01604S 1600 A 62 mm x 139 mm LVCT02004S 2000 A 62 mm x 139 mm LVCT02404S 2400 A 62 mm x 139 mm 1/3 V low-voltage Solid core CTs for Aux inputs (Mains) Commercial ref. no. Amperage rating Inside dimensions LVCT20050S 50 A 10 mm LVCT20100S 100 A 10 mm LVCT20202S 200 A 25 mm LVCT20403S 400 A 31 mm 166 FUNCTIONS AND CHARACTERISTICS Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS BCPM Technical specifications Electrical characteristics Type of measurement Power/energy 1 % system accuracy (including 50A or 100A branch CTs) Accuracy Voltage �0.5 % of reading Current �0.5 % of reading Minimum "ON" current 50mA Sampling rate Points per cycle 2560 Hz Data update rate 1.8 seconds (Modbus), 14 seconds (BACnet) 20 sec (SNMP) Input-voltage characteristics Measured voltage Measurement range Power supply AC 150 � 480 V AC L-L (1) 90 � 277 V AC L-N (1) 150 � 480 V AC L-L (1) 90 � 277 V AC L-N (1) 100 � 277 V AC (50/60 Hz) Auxiliary CT Current Input Range 0-0.333V; CTs must be rated for use with Class 1 voltage inputs Mechanical characteristics Weight 1.5 kg Dimensions A/B/C model Circuit board 288 x 146 mm E model housing (w/brackets on long sides) 253 mm W x 307 mm H x 71 mm D E model housing (w/brackets on short ends) 210 mm W x 353 mm H x 71 mm D Environmental conditions Operating temperature Storage temperature Installation category Safety Europe U.S. and Canada Communication RS-485 (A/B/C models) 0 to 60 �C -40 �C to 70 �C CAT III, pollution degree 2 IEC 61010 UL 508 Open type device Baud rate: DIP-switch selectable 9600, 19200, 38400 DIP-switch selectable 2-wire or 4-wire RS-485. Parity selectable: Even, Odd or None. RS-485 (A models) Baud rate: configured via Web-server. Baud selectable: 9600, 19200, 38400. Parity selectable: Even, Odd or None. 2-wire RS-485. Ethernet (E models) 10/100 Mbit Ethernet. RJ-45 connection. Static IP or DHCP. Protocols Modbus RTU on all models, BCPME models also support Modbus TCP, SNMP, BACnet IP & BACnet MS/TP Firmware characteristics Detection of over-voltage/undervoltage User-defined alarm thresholds for over-voltage and under-voltage detection Alarms Four alarm levels: high-high, high, low and low-low (users define the setpoints for each). Each alarm has a latching status to alert the operator that an alarm has previously occurred. High and Low alarms have instantaneous status to let the operator know if the alarm state is still occurring. Firmware update Update via Modbus Version: 1.0 - 24/01/2020 PLSED309005EN_08 167 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS BCPM 1/3 V low-voltage CT (LVCT) for Mains - Technical specifications Electrical characteristics Accuracy Frequency range Leads Max. voltage L-N sensed conductor Environmental conditions Operating temperature Storage temperature Humidity range 1 % from 10 % to 100 % of rated current(LVCT0xxxx0S/1S/2S/3S/4S [split-core]) 0.5 % from 5 % to 100 % of rated current (LVCT2xxxx0S/2S/3S [solid core]) 50/60 Hz 18 AWG, 600 V AC, 1.8m standard length 300 V AC (LVCT0xxxx0S) 600 V AC (LVCT0xxxx1S/2S/3S/4S, LVCT2xxxxxS) 0 �C to 70 �C (LVCT0xxxx0S/1S) -15 �C to 60 �C (LVCT0xxxx2S/3S/4S less than 2400A) -15 �C to 60 �C (LVCT02404S [2400A]) -40 �C to 85 �C (LVCT2xxxx0S/2S/3S [solid core]) -40 �C to 105 �C (LVCT0xxxx0S/1S) -40 �C to 70 �C (LVCT0xxxx2S/3S/4S) -50 �C to 105 �C (LVCT2xxxx0S/2S/3S [solid core]) 0 to 95 % non-condensing 168 Version: 1.0 - 24/01/2020 PLSED309005EN_08 PE86286_m MULTI-CIRCUIT METERING BCPM PowerLogic BCPM dimensions PowerLogic BCPM adapter board (one board per 21 splitcore branch CTs) PE86169 DIMENSIONS AND CONNECTION PB113661 PB113662 Version: 1.0 - 24/01/2020 PLSED309005EN_08 169 PB113659 MULTI-CIRCUIT METERING BCPM 50 A-200 A Split-core CT dimensions DIMENSIONS AND CONNECTION PB113659 PB113659 These dimensions apply to both BCPMSCCTxx (branch CTs) and LVCT0xxxx0S/1S (for Mains) 50 A-200 A CT families. Solid core CT dimensions 1/3 V low-voltage CT form factor Model LVCT20050S LVCT20100S LVCT20202S LVCT20403S L A B C D E 1.8 m 33 mm 38 mm 18 mm 21 mm 10 mm 1.8 m 1.8 m 59 mm 70 mm 66 mm 82 mm 18 mm 25 mm 31 mm 36 mm 25 mm 31 mm Small form factor 100/200/300 Amp A = 96 mm B = 30 mm C = 31 mm D = 30 mm E = 100 mm F = 121 mm Medium form factor 400/600/800 Amp A = 125 mm B = 73 mm C = 62 mm D = 30 mm E = 132 mm F = 151 mm Large form factor 800/1000/1200/ 1600/2000/2400 Amp A = 125 mm B = 139 mm C = 62 mm D = 30 mm E = 201 mm F = 151 mm PB113660_m PB113663 170 Version: 1.0 - 24/01/2020 PLSED309005EN_08 PE86171 MULTI-CIRCUIT METERING DIMENSIONS AND CONNECTION BCPM PowerLogic BCPM with solid core CT strips installation details Mains monitoring (CTs ordered separately) Circuit monitoring 4 CT strips monitor up to 84 circuits Transducers (1/3 Vac) BCPM PCB PowerLogic BCPM with split-core CTs installation details PE86287 Version: 1.0 - 24/01/2020 PLSED309005EN_08 171 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS EM4000 series The compact PowerLogic EM4000 series multi-circuit energy meter from Schneider Electric enables the reliable reliable monitoring of building electrical loads iwith a low installation cost-per-point by combining revenue-accurate electricity sub-metering with advanced communications technology. Applications � Energy management � Energy cost allocation � Utility bill verification PB113714 172 METSEEM403316 Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic EM4000 series meters: � Buildings � Industry � Healthcare � Data Centre and networks � Infrastructure Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance Competitive advantages � Compact, maintenance-free design � Hi-density, flexible connection � Direct connection � Multiple CT types � No rewiring required � Integrated communications networks. Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC 61557-12 � IEC 61000-4-4 � IEC 62053-22 � IEC 61000-4-5 � IEC 62053-24 � IEC 61000-4-6 � IEC 61010-1 � IEC 61000-4-8 � IEC 61000-4-2 � Etc. � IEC 61000-4-3 Version: 1.0 - 24/01/2020 PLSED309005EN_08 173 PB113714 MULTI-CIRCUIT METERING EM4000 series EM4000 series multi-circuit energy meter FUNCTIONS AND CHARACTERISTICS The compact PowerLogic EM4000 series multi-circuit energy meter from Schneider Electric enables the reliable monitoring of building electrical loads iwith a low installation cost-per-point by combining revenue-accurate electricity sub-metering with advanced communications technology. The EM4000 is ideal for departmental metering applications and M&V within office towers, condominiums, apartment buildings, shopping centres and other multi-user environments, or small-footprint retail. The PowerLogic EM4000 series meters monitor up to 24 meter points with a single device. Multiple meters can be combined to support an unlimited number of points. Two meter models offer a choice of CTs and installation options: � PowerLogic EM4033: 333 mV, split-core CTs � PowerLogic EM4080: 80 mA solid core CTs Main characteristics � Compact, maintenance-free design �� Requires no floor space � Hi-density, flexible connection �� From single-pole to single- or three-phase metering, supports up to 24 circuits. �� Select the connection type using an intuitive configuration tool. � Direct connection �� For 100 - 300 V AC L-N electrical distribution systems: 120/240 V, 120/208 V, 277/480 V � Multiple CT types �� Support a variety of needs in both new and retrofit installations. �� 1/3 V output CT option does not require shorting blocks, making it the ideal choice for retrofit installations. � No rewiring required �� Use existing wiring to connect to existing panels. � Integrated communications networks. �� Onboard Ethernet or RS-485 allows for easy integration into existing communications networks. Feature selection Commercial ref. no. Model METSEEM403316 METSEEM403336 EM4033 METSEEM408016 METSEEM408036 EM4080 Description PM5310 Cl 0.5, RS-485 Modbus, 2DI/2DO PM5330 Cl 0.5, RS-485 Modbus, 2DI/2DO, Relay PM5331 Power & Energy meter PM5320 Power & Energy meter 174 Version: 1.0 - 24/01/2020 PLSED309005EN_08 PB113718 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS EM4000 series PowerLogic EM4000 meter 480Y/277V three-phase wye service connection Selection guide General Use on LV systems Accuracy Accuracy compliance +/- 0.5 % ANSI C12.1 and C12.20 Class 0.5; IEC 62053-22, Class 0.5S Maximum circuits: single-pole / single-phase / three-phase 24 / 12 / 8 Instantaneous rms values Energy real, kWh received/delivered reactive, kvarh received/delivered apparent, VAh Voltage Pulse counts Voltage and current V rms, I rms per phase Power real, reactive, apparent Power factor Measurements available for data logging Energy real, kWh received/delivered reactive, kvarh received/delivered apparent, VAh Voltage Display Backlit LCD display 2 lines of 16 characters Optional remote modular display available Communication Ethernet port MODBUS-RTU over RS-485 Pulse inputs 2 Protocols: Modbus TCP/IP, HTTP, BACnet/IP, FTP, and SNTP Installation options 0.333 V CTs 80 mA CTs Split-core CT Solid core CT EM4033 EM4080 b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b Legend: 1 Cover screw location 2 Meter point input connector 3 Cable connector 4 Mounting keyhole 5 Ingress punch-outs 6 Earth stud 6 Sense voltage terminal block 8 Control voltage terminal block 9 Fuse 10 Control voltage jumper 11 RTU interface 12 Display 13 Remote display connector 14 Serial RS-232 15 Ethernet port 16 Pulse in terminal blocks 17 Pulse out connector PB113716 Version: 1.0 - 24/01/2020 PLSED309005EN_08 175 MULTI-CIRCUIT METERING EM4000 series EM4000 technical specifications Electrical characteristics Input-voltage characteristics Inputs Measured voltage Frequency range Mechanical characteristics Weight Dimensions EM4033/EM4080 EM4033/EM4080 Environmental conditions Operating temperature Storage temperature Humidity rating Enclosure Altitude Pollution degree Safety and standards UL Certified to IEC/EA/CSA 61010-1 CSA-C22.2 No 61010-1-04 FCC Part 15 Class B ICES-003 EN 55022, IEC 6100-4-5 ANSI/TIA968-A: 2002 Communication Ports Pulse inputs Protocols: Modbus TCP/IP, HTTP, BACnet/IP, FTP, and SNTP Display characteristics Integrated backlit LCD display FUNCTIONS AND CHARACTERISTICS V1, V2, V3, Vn 80 - 480 V AC L-L without PTs Up to 999 kV with external PTs 60 Hz approx. 4.0 kg 335 x 305 x 55 mm -40 �C to 70 �C -40 �C to 70 �C 0 % to 90 % RH non-condensing Type 1 (indoor or enclosed outdoor use) 3000 m 2 Ethernet MODBUS-RTU over RS-485 2 2 lines, 16 digits per line display; R / L arrow buttons select metering point; Display button cycles through measurements per point. 176 Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING EM4X00, CT termination, PT module DIMENSIONS AND CONNECTION PB113726 PB113719 EM4X00, CT termination, PT module Version: 1.0 - 24/01/2020 PLSED309005EN_08 177 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS PB113724 EM4000 series METSEPTMOD480 PT Module The PT module provides step-down voltage connections to Schneider Electric PowerLogic meters for metering single-phase to three-phase voltages of 600 V, 347 V, or 400 V, while meeting all regulatory electrical safety and ANSI 0.5 Accuracy Class standards. The PT module provides both the per-phase input metering voltages and the auxiliary input power required by Schneider Electric PowerLogic energy meters. There are two variants of the PT module that support the following source voltages and wiring configurations: � 347 V Wye / 600 V Delta variant supports: �� 347 V, three-phase, 4-wire wye �� 600 V, three-phase, 3-wire delta � 480V Delta variant supports: �� 480 V, three-phase, 3-wire delta The 347 V/600 V PT module variant has three sense voltage potential transformers for metering. The configuration of the transformers (347 V wye or 600 V delta) is selected by using the jumper provided. The 480V PT module has two sense voltage potential transformers for metering. There is a separate auxiliary power transformer in both variants to operate the meter. All voltage inputs are fused. PowerHawk PT module specifications Dimensions Height Width Depth Weight Fuse ratings High voltage inputs Voltage inputs Transformer specifications Input voltage Environmental Output voltage Operating temperature Operating humidity Usage environment Maximum altitude Pollution degree 213.1 mm 54 mm 54 mm 5.67 kg F1 F2 F3 F4 F5 F6 F7 600 V T315 mA, 1000 V T315 mA, 1000 V T315 mA, 1000 V T250 mA, 250 V T250 mA, 250 V T250 mA, 250 V T250 mA, 250 V Voltage tolerance: +/-10 % 480 V Voltage tolerance: +/-10 % 347 V Voltage tolerance: +/-10 % 120 V Accuracy: 0.3 % -40 �C to 70 �C 5 % to 90 % non-condensing Indoor or enclosed outdoor environment 3000 m 2 178 Feature selection Commercial ref. no. METSEPTMOD480 METSEPTMOD347600 Description 480 V PT Module for EM4X00 meter 347 V/600 V PT Module for EM4X00 meter Version: 1.0 - 24/01/2020 PLSED309005EN_08 PB113725 MULTI-CIRCUIT METERING EM4000 series FUNCTIONS AND CHARACTERISTICS CT Module PowerLogic 4080 meters have two shorting options that provide a seamless and sealable mechanical package. The CT Shorting Module provides CT connections via the color coded 25 pair cable routed into the breaker panel. All CTs are shorted at the same time for safe removal of the meter for maintenance when the electrical circuits are still live. The CT Termination Module has the same shorting ability, but provides CT connections via 24 2-position screw-down terminal blocks. Individual pairs are then routed from the CT Termination Module to 1 or more breaker panels via conduit knock outs provided on the module. Thus eliminating the need for a splitter box to route CT cables to multiple panels. Commercial ref. no. METSECTTERM METSECTSHORT Description CT Termination Module for EM4X00 meter CT Shorting Module for EM4X00 meter Converter The 5 A:80 mA converter is useful in applications where there are existing 5 A CT's integrated into large motors or switch gear. The 5 A:80 mA converter matches the 5 A secondary of the load to the 80 mA input of the meter. In Billing Grade applications, the 5 A:80 mA converter is also used to connect regulatory grade large aperture, large amperage CT's with 5 A secondaries to the 80 mA of PowerLogic 4 X 80 meters. Commercial ref. no. METSECONV580 Description 5 A : 80 mA converter for EM4X00 meter METSECONV580 PB113729 PB111056 Version: 1.0 - 24/01/2020 PLSED309005EN_08 The 5 A to 80 mA converter dimensions See appropriate Installation Guide for this product. 179 PB111061 MULTI-CIRCUIT METERING EM4000 series Legend: 1 Source 2 Energy flow 3 Load 4 X1 5 X2 DIMENSIONS AND CONNECTION CTs � Model 8 (80/100 mA Secondary) � Window Size: 82.5 mm Diameters � Application: Metering � Frequency: 50-400 Hz � Insulation Level: 600 Volts, 10 Kv BIL Full Wave � Flexible leads available for all case configurations. Flexible leads are UL 1015 105 �C, CSA approved #16 AWG, 609.6 mm long standard length. Non-s tandard lengths are available upon request. � Terminals are brass studs No. 8-32 UNC with one flat washer, one lock washer and one nut each. Terminals are only available on the square case configuration. � Mounting brackets kits for the Model 8SHT are available when required. � Approximate weight: 1.36 kg PB111060 PB111059 200 A CT 200 A CT dimensions PB113972 PB113971 Feature selections Commercial reference number Description METSECT80200 CT, solid core, 200 A primary, 80 mA secondary, for use with EM4X80 multi-circuit meter METSECT80400 CT, solid core, 400 A primary, 80 mA secondary, for use with EM4X80 multi-circuit meter METSECT80600 CT, solid core, 600 A primary, 80 mA secondary, for use with EM4X80 multi-circuit meter 400 A CT METSECT80600 600 A 80 mA CT 180 PB111057 PB111057 PB111058 400 A CT dimensions 600 A 80 mA CT dimensions Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING DIMENSIONS AND CONNECTION EM4800 series The compact PowerLogic EM4800 series multi-circuit energy meter from Schneider Electric enables reliable metering of individual tenants with a low installation cost-per-point by combining revenueaccurate electricity sub-metering with advanced communications technology.The ideal fit for high-end cost management applications, providing the measurement capabilities needed to allocate energy usage, perform tenant metering and sub-billing, pin-point energy savings, optimise equipment efficiency and utilisation, and perform a high level assessment of the power quality in an electrical network. Applications Capable of essential cost management: � Multi-tenant metering � Energy management � Energy cost allocation � Utility bill verification PE86325 Version: 1.0 - 24/01/2020 PLSED309005EN_08 METSEEM480525 181 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic EM4800 series meters: � Buildings � Industry � Healthcare � Data Centre and networks � Infrastructure Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance Competitive advantages � Compact, maintenance-free design � Hi-density, flexible connection � Direct connection � Multiple CT types � No rewiring required � Integrated communications Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC61557-12 � IEC 61000-4-4 � IEC62053-22 � IEC 61000-4-5 � IEC62053-24 � IEC 61000-4-6 � IEC 61010-1 � IEC 61000-4-8 � IEC 61000-4-2 � Etc. � IEC 61000-4-3 182 Version: 1.0 - 24/01/2020 PLSED309005EN_08 PE86326 PE86325 MULTI-CIRCUIT METERING EM4800 series EM4800 series multi-circuit energy meter front (above), installed in panel (below) Version: 1.0 - 24/01/2020 PLSED309005EN_08 FUNCTIONS AND CHARACTERISTICS The compact PowerLogic EM4800 series multi-circuit energy meter from Schneider Electric enables reliable metering of individual tenants with a low installation cost-per-point by combining revenue-accurate electricity sub-metering with advanced communications technology. The EM4800 is ideal for multi-tenant or departmental metering applications within office towers, condominiums, apartment buildings, shopping centres and other multi-user environments. The PowerLogic EM4800 series meters monitor up to 24 tenants with a single device. Multiple meters can be combined to support an unlimited number of suites. � Three meter models offer a choice of CT secondary ratings and installation options: �� PowerLogic EM4805: 5 A, split or solid core CTs �� PowerLogic EM4833: 0.333 V, split or solid core CTs �� PowerLogic EM4880: 80 mA, solid core CTs � Main characteristics �� Compact, maintenance-free design �� Requires no floor space. � Hi-density, flexible connection �� From single-pole to single- or three-phase metering, supports up to 24 circuits. Select the connection type using an intuitive configuration tool. � Direct connection �� For 100 - 300 V AC L-N electrical distribution systems: �� 120/240 V, 120/208 V, 230/240 V, 220/380 V, 240/415 V, 277/480 V � Multiple CT types �� Support a variety of needs in both new and retrofit installations. �� 1/3 V output CT option does not require shorting blocks, making it the ideal choice for retrofit installations. � No rewiring required �� Use existing wiring to connect to existing panels. � Integrated communications �� Onboard Ethernet and modem allows for easy integration into existing communications networks. Feature selections Commercial ref. no. METSEEM480525 METSEEM480516 Model EM4805 METSEEM483325 METSEEM483316 EM4833 METSEEM488016 METSEEM488025 EM4880 Description 24 x 5 A inputs, 230/240 V control power, 50 Hz 24 x 5 A inputs, 120 V control power, 60 Hz 24 x 333 mV inputs, 230/240 V control power, 50 Hz 24 x 333 mV inputs, 120 V control power, 60 Hz 24 x 80 mA inputs, 120 V control power, 60 Hz 24 x 80 mA inputs, 230/240 V control power, 50 Hz 183 PE86327A MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS EM4800 series PowerLogic EM4800 series digital panel meter. Selection guide EM4805 EM4833 EM4880 General Use on LV systems Accuracy Accuracy compliance b b b +/- 0.5 % b b b ANSI C12.1 and C12.20 Class 0.5; b b b IEC 62053-22, Class 0.5S Maximum circuits: single-pole / single phase / three-phase 24 / 12 / 8 b b b Instantaneous rms values Energy Real, kWh received/delivered b b b Reactive, kvarh received/ delivered b b b Apparent, VAh b b b Voltage b b b Pulse counts b b b Voltage and current V rms, I rms per phase b b b Power Real, reactive, apparent b b b Power factor b b b Measurements available for data logging Energy Real, kWh received/delivered b b b Reactive, kvarh received/ delivered b b b Apparent, VAh b b b Voltage b b b Display Backlit LCD display 2 lines of 16 characters b b b Optional remote modular display available b b b Communication Ethernet port b b b V.90 modem port b b b Pulse inputs 2 b b b Protocols: Modbus TCP/IP, HTTP, BACnet/IP, FTP, and SNTP b b b Installation options 5 A CTs b 0.333 V CTs b 80 mA CTs b Split-core CT b b Solid core CT b b b Remote modular display b b b 184 Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS EM4800 series Electrical characteristics Input-voltage Inputs characteristics Measured voltage Frequency range Mechanical characteristics Weight EM4805 EM4833/EM4880 Dimensions EM4805 EM4833 / EM4880 Environmental conditions Operating temperature Storage temperature Humidity rating Enclosure Altitude Pollution degree Safety and standards UL Certified to IEC/EA/CSA 61010-1 CSA-C22.2 No 61010-1-04 FCC Part 15 Class B ICES-003 EN55022, IEC 6100-4-5 ANSI/TIA968-A: 2002 Communication Ports Pulse inputs Protocols: Modbus TCP/IP, HTTP, BACnet/IP, FTP, and SNTP Display characteristics Integrated backlit LCD display V1, V2, V3, Vn 80 - 480 V AC L-L without PTs Up to 999 kV with external PTs 50/60 Hz approx. 5.4 kg approx. 4.0 kg 335 x 44 x 55 mm 335 x 305 x 55 mm -40 �C to 70 �C -40 �C to 70 �C 0 % to 90 % RH non-condensing Type 1 (indoor or enclosed outdoor use) 3000 m 2 Ethernet V.90 modem 2 2 ines, 16 digits per line display; R / L arrow buttons select metering point; Display button cycles through measurements per point. Version: 1.0 - 24/01/2020 PLSED309005EN_08 185 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS EM4900 series The PowerLogic EM4900 Series Multi-Circuit Meters make it easy to add many metering points without having to purchase, mount, wire and commission individual energy meters. Simply add a single device with common voltage inputs and communication interface that can measure the current, voltage, power, energy consumption, and Total harmonic Distorion (THD) of up to (14) 3-phase circuits with a single board or up to (28) 3-phase circuits with a two board configuration. Save on both equipment cost and installation. Applications � Commercial and residential subtenant billing � Load-based cost allocation � Measuring for load balancing and demand response � Overload protection PB117150 PB117149 186 METSEEM4904E METSEEM4904A Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic EM4900 series meters: � Buildings � Industry � Healthcare � Hotels, Multi-Dweller Units (condos) Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance Competitive advantages � Lower cost and space per metering point � Adapts to any mix of metering needs (1ph, 2ph, 3ph with or without Neutral wire) � Class 0.5 accuracy for Revenue Grade measurement � THD monitoring to help identify problem loads and early wear and tear � Capable of concurrent communication to software packages, including PowerLogic software packages and third party systems Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � EN 61000-6-3 Class B - Part 6-3 � EN 61000-6-3 Class B - Part 6-3 � EN 61000-6-4 Class A - Part 6 � EN 61010-1 - Part 1 � EN 61326-1 Class A - Part 1 � EN 61326-1 Class B - Part 1 � IEC 62053-22 Class 0.5 - Part 21 � FCC 47 CFR Part 15 Class A & Class B � UL 508 Open Device Type � IEC 61010-1 - Part 1 Version: 1.0 - 24/01/2020 PLSED309005EN_08 187 PB117149 PB117153 MULTI-CIRCUIT METERING EM4900 series PowerLogicTM EM4914A PowerLogicTM EM4914E 28 Meter adapter board (EM4928A and EM4928E) FUNCTIONS AND CHARACTERISTICS To aid in commissioning, a configuration software tool, an Ethernet discovery tool (for the EM49xxE) and a User Guide are available online at www.schneider-electric.com. � Main characteristics �� Add lots of metering points without lots of cost �� Add up to 28 3-phase meters by installing a single product small enough to fit inside many distribution panels. Save on both equipment cost and installation cost. Common voltage and communication connections and color-coded push-in CT connections save installation time and effort. �� Class 0.5 accuracy for Revenue Grade measurements �� Power and Energy measurements with ANSI and IEC class 0.5 accuracy provide the accuracy needed for tenant billing applications. Voltage and current measurement accuracy is 0.5 % and currents are measured down to 0.1% of the CT range. Easily differentiate between the flow of low current and a trip or load disconnect where no current flows. �� Total Harmonics Distorion measurements �� Helps assess basic power quality to reduce risks to the load and provide indication of potential early wear and tear of the electrical network and its load. �� Common CTs, 1/3V outputs �� CTs with low-voltage outputs eliminate the need for shorting blocks that add cost and labor to the installation. They also allow long CT lead extensions without compromising accuracy. Choose from a range of our CT styles and sizes or use any CTs with industrystandard 0.333V outputs. �� Models with integrated Ethernet offer broad protocol support �� All models integrate easily into existing networks using Modbus RTU communications over an RS-485 serial link. EM49xxE models offer integrated Ethernet and add support for Modbus TCP, BACnet IP, BACnet MS/TP and SNMP. Those Ethernet protocols can be run in parallel allowing multiple software to access the device (Building Management System, Energy Management System, etc.) An optional external gateway can be added to EM49xxA models to offer the same capability. �� Compatible with PowerLogic power monitoring software �� Easily turn the large amount of data collected by the devices into useful decision making information. �� Configure the meters you want �� Choose 4, 8, 14 or 28 3-phase meters. User-configurable to any combination of 1-, 2-, 3-phase meters. Reconfigure channels as needed to monitor neutral current. PB117151 188 Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS EM4900 series specifications Measurements Measurement voltage Total Harmonic Distortion (THD) Control power EM49xxA EM49xxE Accuracy Power/Energy Voltage Current Operation Sampling frequency Update rate Overload capability EM49xxA serial communication Type Connection Address Baud rate Parity Communication format Termination EM49xxE serial communication Physical Interface Serial protocols supported Address range Baud rate Parity Communication format Termination EM49xxE Ethernet communication Physical interface Protocols supported Wire size range Removable connectors on main board CT Terminals and EM49xxE serial connector terminals Terminal block torque Removable connectors Mechanical Ribbon cable support (28-meter models only) Operating conditions Operating temperature range Storage temperature range Altitude of operation Mounting location Compliance information Agency approvals Installation category Conducted emissions Radiated emissions Conducted and radiated immunity 90 t0 300 V AC L-N, 50/60 Hz THD % voltage L-L, L-N and THD % on current 90 to 277 V AC L-N, 50/60 Hz 100 to 277 V AC L-N, 50/60 Hz IEC 62053-21 Class 0.5, ANSI C12.20 class 0.5 �0.5% of reading 90 to 277 V L-N �0.5% of reading from 2% to 100% of full-scale 2560 Hz 1.8 seconds (both panels) 22 kAIC Modbus RTU DIP switch-selectable 2-wire or 4-wire, RS-485 DIP switch-selectable address 1 to 247 (in pairs of 2) (See Installation Guide) DIP switch-selectable 9600, 19200, 38400 DIP switch-selectable NONE, ODD, EVEN 8 data bits, 1 start bit, 1 stop bit 5-position plug-in connector (TX+ TX- SHIELD TX+/RX+ TX-/RX-) 2-wire RS-485 Modbus RTU or BACnet MS/TP 1 to 247 for Modbus RTU; 0 to 127 for BACnet MS/TP 9600, 19200, 38400 Modbus RTU: NONE, ODD, EVEN BACnet MS/TP: NONE (fixed) 8 data bits, 1 start bit, 1 stop bit 2x3 position connector Protocols Supported Modbus TCP, BACnet IP, SNMP V2c 24 to 12 AWG 26 to 16 AWG 0.5 to 0.6 N-m 0.9 m round ribbon cable ships standard; up to 6 m flat or round available 0 to 60 �C (<95% RH non-condensing) -40 to 70 �C 3000 m Not suitable for wet locations. For indoor use only. UL 508 open type device+1, IEC/EN 61010-1 Cat III, pollution degree 2+2 EM49xxA Models: FCC part 15 Class B, EN 61000-6-3, EN 61326-1 Class B (residential & light EM49xxE Models: FCC part 15 Class A, EN 6100-6-4, EN 61326-1 Class A EN 61000-6-2 and EN 61326-1 +1Install EM49xx in apprpropriate fire enclosure; if used with circuits higher than product ratings, circuits must be segregated per UL 508A Sec 17.5 (EM49xx internal circuitry are not circuits as defined by UL 508A). +2 A Pollution Degree 2 environment must control conductive pollution and the possibility of condensation or high humidity. Consideration must be given to the enclosure, the correct use of ventilation, thermal properties of the equipment and the relationship with the environment. Version: 1.0 - 24/01/2020 PLSED309005EN_08 189 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS EM4900 series 1/3 V low-voltage CT (LVCT) Electrical characteristics Accuracy Frequency range Leads Max. voltage L-N sensed conductor Measurements Real time measurements Demand measurements Historic maximums Accumulate energy Energy snapshots 1 % from 10 % to 100 % of rated current(LVCT0xxxx0S/1S/2S/3S/4S [split-core]) 0.5 % from 5 % to 100 % of rated current (LVCT2xxxx0S/2S/3S [solid core]) 50/60 Hz 18 AWG, 600 V AC, 1.8 m standard length 300 V AC (LVCT0xxxx0S) 600 V AC (LVCT0xxxx1S/2S/3S/4S, LVCT2xxxxxS) Current: multi-phase average and per phase Current phase angle per branch Real power (kW): multi-phase total and per phase Apparent power (kVA): multi-phase total and per phase Power factor: multi-phase average and per phase Current present demand: multi-phase average and per phase Real power (kW) present demand: multi-phase average and per phase Maximum instantaneous current: multi-phase average and per phase Maximum current demand: multi-phase average and per phase Maximum real power demand: multi-phase total and per phase Energy (kWh): multi-phase total and per phase Energy (kWh): multi-phase total and per phase 190 Version: 1.0 - 24/01/2020 PLSED309005EN_08 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS PB117149 EM4900 series 1 23 METSEEM49 14 E 1 Model. 2 Number of 3-phase meters (without neutral current) 3 Communication interfaces & protocols. EM49xxA Main Board PB117150 EM49xxE Main Unit EM4900 series part numbers - BCPM with solid core CTs Item 1 Model 2 Number of 3-phase Meters 3 Communication Interfaces & Protocols Code METSEEM49 04 08 14 28 A E Description Multi-Circuit Meter Up to (4) 3-phase Meters (see table for variations) Up to (8) 3-phase Meters (see table for variations) Up to (14) 3-phase Meters (see table for variations) Up to (28) 3-phase Meters (see table for variations) RS-485 Serial with Modbus RTU (add E8951 for other protocols) Ethernet with Modbus TCP, BACnet IP and SNMP protocols and RS-485 Serial with Modbus RTU or BACnet IP Commercial ref. no. "E" - Integrated Ethernet METSEEM4904A METSEEM4904E METSEEM4908A METSEEM4908E METSEEM4914A METSEEM4914E METSEEM4928A METSEEM4928E Number of meters 3-phase 2-phase 1-phase 4 6 12 8 12 24 14 21 42 28 42 84 Number of meters supported: EM4900 models are all factory-configured as all 3-phase meters (w/o neutral). They can be easily re-configured to any combination of 1-ph, 2-ph or 3-ph meters (with ION Setup). Any unused channels can be used to measure neutral current. Label overlays (to re-number CT connections) are provided for 1-ph/2-ph applications. Commercial ref. no. EM4900 multi-circuit meters METSEEM4904A Multi-Circuit Meter � (4) 3-phase meters - Modbus RTU only METSEEM4908A Multi-Circuit Meter � (8) 3-phase meters - Modbus RTU only METSEEM4914A Multi-Circuit Meter � (14) 3-phase meters - Modbus RTU only METSEEM4928A Multi-Circuit Meter � (28) 3-phase meters - Modbus RTU only METSEEM4904E METSEEM4908E METSEEM4914E METSEEM4928E Multi-Circuit Meter � (4) 3-phase meters - Ethernet and Serial (Modbus, BACnet & SNMP) Multi-Circuit Meter � (8) 3-phase meters - Ethernet and Serial (Modbus, BACnet & SNMP) Multi-Circuit Meter � (14) 3-phase meters - Ethernet and Serial (Modbus, BACnet & SNMP) Multi-Circuit Meter � (28) 3-phase meters - Ethernet and Serial (Modbus, BACnet & SNMP) PB117151 CT Adapter Assembly (28-Meter models only) Version: 1.0 - 24/01/2020 PLSED309005EN_08 191 PE86284 PB117152 MULTI-CIRCUIT METERING FUNCTIONS AND CHARACTERISTICS EM4900 series Flat ribbon cable CBL008 Round ribbon cable CBL022 LVCT00050S PowerLogicTM LVCT0xxxxS split-core Low-voltage (1/3V) CTs are ideal for retrofit applications EM4900 series accessories Commercial Description reference number BCPMCOVERS EM4900 circuit board cover E8951 Modbus to BACnet protocol converter Ribbon cables for 28-meter models 1.22 m cables are standard � others must be ordered separately CBL008 Flat Ribbon cable (quantity 1) for BCPM, length = 0.45 m CBL016 Flat Ribbon cable (quantity 1) for BCPM, length = 1.2 m CBL017 Flat Ribbon cable (quantity 1) for BCPM, length = 1.5 m CBL018 Flat Ribbon cable (quantity 1) for BCPM, length = 1.8 m CBL019 Flat Ribbon cable (quantity 1) for BCPM, length = 2.4 m CBL020 Flat Ribbon cable (quantity 1) for BCPM, length = 3.0 m CBL021 Flat Ribbon cable (quantity 1) for BCPM, length = 6.1 m CBL022 Round Ribbon cable (quantity 1) for BCPM, length = 1.2 m CBL023 Round Ribbon cable (quantity 1) for BCPM, length = 3 m CBL024 Round Ribbon cable (quantity 1) for BCPM, length = 6.1 m CBL031 Round Ribbon cable (quantity 1) for BCPM, length = 0.5 m CBL033 Round Ribbon cable (quantity 1) for BCPM, length = 0.8 m 1/3 V low-voltage Split-core CTs Commercial Amperage rating reference number LVCT00050S 50 A LVCT00101S 100 A LVCT00201S 200 A LVCT00102S 100 A LVCT00202S 200 A LVCT00302S 300 A LVCT00403S 400 A LVCT00603S 600 A LVCT00803S 800 A LVCT00804S 800 A LVCT01004S 1000 A LVCT01204S 1200 A LVCT01604S 1600 A LVCT02004S 2000 A LVCT02404S 2400 A Inside dimensions 10 x 11 mm 16 x 20 mm 32 x 32 mm 30 x 31 mm 30 x 31 mm 30 x 31 mm 62 x 73 mm 62 x 73 mm 62 x 73 mm 62 x 139 mm 62 x 139 mm 62 x 139 mm 62 x 139 mm 62 x 139 mm 62 x 139 mm 1/3 V low-voltage Solid core CTs Commercial Amperage rating reference number LVCT20050S 50 A LVCT20100S 100 A LVCT20202S 200 A LVCT20403S 400 A Inside dimensions 10 mm 10 mm 25 mm 31 mm PE86183 PB113652 PB113657 PB113658 LVCT20050S PowerLogicTM LVCT2xxxxS Low-voltage (1/3V) solid core CTs are ideal for panel builders (small, medium, large) 192 Version: 1.0 - 24/01/2020 PLSED309005EN_08 PE86169_m MULTI-CIRCUIT METERING EM4900 series EM49xxA main board dimensions mm DIMENSIONS AND CONNECTION PB119356_m 28-Meter CT adapter assembly dimensions PB117144_m Version: 1.0 - 24/01/2020 PLSED309005EN_08 193 MULTI-CIRCUIT METERING EM4900 series 50 A-200 A Split-core CT dimensions DIMENSIONS AND CONNECTION CT rating 50 A A 26 mm B 11 mm C 10 mm D 23 mm E 40 mm 100 A 28 mm 16 mm 16 mm 40 mm 52 mm 200 A 37 mm 32 mm 32 mm 62 mm 69 mm PB113659 PB113660 Solid core CT dimensions Split-core CT dimensions - see table. 194 Model LVCT20050S LVCT20100S L A B C D E 1.8 m 33 mm 38 mm 18 mm 21 mm 10 mm LVCT20202S 1.8 m 59 mm 66 mm 18 mm 31 mm 25 mm LVCT20403S 1.8 m 70 mm 82 mm 25 mm 36 mm 31 mm 1/3 V low-voltage CT form factor Small form factor 100/200/300 A Medium form factor 400/600/800 A Large form factor 800/1000/1200/ 1600/2000/2400 A A = 96 mm B = 30 mm C = 31 mm A = 125 mm B = 73 mm C = 62 mm A = 125 mm B = 139 mm C = 62 mm D = 30 mm D = 30 mm D = 30 mm E = 100 mm E = 132 mm E = 201 mm F = 121 mm F = 151 mm F = 151 mm Version: 1.0 - 24/01/2020 PLSED309005EN_08 PB113663 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS Retrofit Products The advantages of using retrofit products throughout your power monitoring system are numerous and proven. Whether you install these products as part of an upgrade or as add-on modules in a new build environment, ease of installation and commissioning will reap huge economic benefits. The PowerLogic range is designed to retrofit existing switchboards and enhance the energy efficiency of buildings for many years. These products are: � � Easy and cost-effective to install � � Able to collect a broad scop of electrical data � � Able to utilize a variety of meters to measure WAGES (Water, Air, Gas, Electricity, Steam) usage � � Transmit all data to a centralized data concentrator for detailed analysis PB105431 PB115451 Version: 1.0 - 24/01/2020 PLSED309005EN_09 METSEEM3502 METSEEM4235 195 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS EM3500 series The EM3500 Series DIN Rail Meter combines exceptional performance and easy installation to deliver a costeffective solution for power monitoring applications. The EM35xx can be installed on standard DIN rail or surface mounted as needed. Pulse output and phase alarms provide additional versatility. Applications Capable of essential cost management: � Energy monitoring in building automation systems � Renewable energy monitoring � Commercial sub-metering � Energy management � Industrial monitoring � Accurate cost allocation PB105431 196 METSEEM3502 Version: 1.0 - 24/01/2020 PLSED309005EN_09 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic EM3500 series meters: � Buildings � Industry � Healthcare � Data Centre and networks � Infrastructure Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance Competitive advantages � DIN rail mounting option; easy installation � Real energy output and phase loss alarm output � 90-600 V AC; application versatility with fewer models to stock � Bright backlit LCD; easy visibility in dark enclosures � Data logging capability safeguard during power failures � EM35xx models compatible with LVCTs from 5 A to 32000 A � User-enabled password protection prevents tampering � Native BACnet MS/TP support (no gateway) Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � IEC 61557-12 � IEC 61000-4-4 � IEC 62053-22 � IEC 61000-4-5 � IEC 62053-24 � IEC 61000-4-6 � IEC 61010-1 � IEC 61000-4-8 � IEC 61000-4-2 � Etc. � IEC 61000-4-3 Version: 1.0 - 24/01/2020 PLSED309005EN_09 197 PB105431 PB113728 PB113727 RETROFIT PRODUCTS EM3500 series PowerLogicTM EM3500 EM3500 parts and connection terminals FUNCTIONS AND CHARACTERISTICS The data logging capability (EM3555 and EM3560) protects data in the event of a power failure. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. Additional pulse inputs on EM3560 provide an easy way to incorporate simple flow sensors to track gas, water, steam, or other energy forms using a BACnet system in addition to full monitoring of electrical energy. EM35xxA (Pulse, Modbus, BACnet) models designed for use exclusively with Rogowski coil CTs where integrator and power supply for the CTs are built into the meter, resulting in fewer devices to purchase and faster to install. (Not recommended for high harmonic applications.) The EM3555 models adds a bi-directional monitoring feature designed expressly for renewable energy applications, allowing measurement of power imported from the utility grid as well as power exported from the renewable energy source (e.g. solar panels). In this way, a facility administrator track all energy data, ensuring accuracy in billing and crediting. � Features �� All Models: A compact solution for panelboard monitoring �� DIN rail mounting option; easy installation �� ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S for all 35xx models; great for cost allocation �� ANSI C12.20 0.5% accuracy, IEC 62053-22 Class 0.5S for EM35xxA models �� Real energy output and phase loss alarm output on EM3502(A), EM3550(A), and EM3555 models; one device serves multiple applications �� 90-600 VAC; application versatility with fewer models to stock �� Bright backlit LCD; easy visibility in dark enclosures �� Data logging capability EM3555 & EM3560(A); safeguard during power failures �� EM35xx models compatible with LVCTs from 5 A to 32000 A; wide range of service types �� User-enabled password protection; prevents tampering �� EM35xxA models are designed to work exclusively with Rogowski coil CTs 20-5000 A range. Eliminate site walks, save time and money. (Not recommended in high harmonic applications.) �� System integration via Modbus EM355xx(A) or BACnet MS/TP EM356xx(A); convenient compatibility with existing systems �� Native BACnet MS/TP support (no gateway) with serial rates up to 115.2 kbaud EM3560, EM3561, EM3560A, & EM3561A �� EM3555 Models: An essential solution for Solar and other renewable energy applications �� Bi-directional metering (4-quadrant); allows net metering �� Data logging capability; ensures long term data retrieval �� CSI approved EM3502/EM355x parts and connection terminals 198 Version: 1.0 - 24/01/2020 PLSED309005EN_09 PB105437 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS EM3500 series EM3500 in enclosure with door open Selection guide Electrical characteristics Inputs Control Power, AC Accuracy Control Power, DC Voltage Input Current Input Scaling Input Range Pulse Inputs (EM3560 & EM3560A) Real Power and Energy 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347V L-N ); CE Maximums: 300 V L-N (520V L-L ) 3W max.; UL and CE: 125 to 300 V DC (external DC current limiting required) UL: 90 V L-N to 600 V L-L ; CE: 90 V L-N to 300 V L 5 A to 32,000 A Non "A" models only 20 A to 5000 A for "A" models only 1/3V and 1V nominal LVCT (selectable) Non "A" models only Rogowski coil CTs only for "A" models Two sets of contact inputs to pulse accumulators 0.2 % (ANSI C12.20, IEC 62053-22 Class 0.2S) EM35xx models only 0.5 % (ANSI C12.20, IEC 62053-22 Class 0.5S) EM35xxA models only Outputs All Models (EM3560, EM3560A, EM3561 & EM3561A) Real Energy Pulse: N.O. static; Alarm contacts: N.C. static EM3502 Reactive energy pulse 30 VAC/DC EM3550, EM3555, EM3550A RS-485 2-wire Modbus RTU (1200 baud to 38.4 kbaud) EM3560, EM3560A, EM3561, EM3561A RS-485 2-wire BACnet MS/TP (9600 baud to 115.2 kbaud) Mechanical characteristics Mounting Environmental conditions DIN Rail or 3-point screw mount Operating temperature Range -30 �C to 70 �C Storage Temperature Range -40 �Cto 85�C Humidity Range <95 % RH non-condensing Accessories NEMA 4x enclosure (EM3500-ENC, pictured) Split-core low voltage CTs (LVCTxx) Fuse kits (EFP1, EFP2, EFP3) Safety US and Canada (cULus) UL508 (open type device)/CSA 22.2 No. 14-05 Europe (CE) EN61010-1:2001 Feature selection Commercial reference number METSEEM3502 METSEEM3550 METSEEM3555 METSEEM3560 METSEEM3502A METSEEM3550A METSEEM3560A METSEEM3561 METSEEM3561A Model EM3502 EM3550 EM3555 EM3560 EM3502A EM3550A EM3560A EM3561 EM3561A Description Pulse out only Modbus - 2 quadrant Modbus - 4 quadrant with logging BACnet with logging Pulse Rope CT model Modbus Rope CT Model BACnet w/ logging Rope CT Model BACnet without logging BACnet without logging Rope CT Model Version: 1.0 - 24/01/2020 PLSED309005EN_09 199 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS EM3502 EM3550 EM3560 EM3561 EM3555 EM3502A EM3550A EM3560A EM3561A EM3500 series EM3500 series Measurement Capability, Full Data Set Bi-directional Energy Measurements b Power (3-phase total and per phase): Real (kW) Reactive (kVAR), and Apparent (kVA) b b b b b b b b b Power Factor: 3-phase average & per phase b b b b b b b b b Present Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) b b b b b b b b b Import and Export totals of Present Power Demand: Real (kW), Reactive (kVAR), & Apparent (kVA) b Peak Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) b b b b b b b b b Current (3-phase average and per phase) b b b b b b b b b Voltage: Line-Line and Line-Neutral (3-phase average and per phase) b b b b b b b b b Frequency b b b b b b b b b ANSI C12.20 0.5 % accuracy, IEC 62053-22 Class 0.5S b b b b ANSI C12.20 0.2 % accuracy, IEC 62053-22 Class 0.2S b b b b b Accumulated Net Energy: Real (kWh), Reactive (kVARh), and Apparent (kVAh) b b b b b b b b b Accumulated Real Energy by phase (kWh) b b b b b b b b b Import and Export Accumulators of Real and Apparent Energy b Reactive Energy Accumulators by Quadrant (3-phase total & per phase) b Demand Interval Configuration: Fixed or Rolling Block b b b b b b b b b Demand Interval Configuration: External Sync to Comms b b b b b b b Data Logging (Store up to 60 days at 15-minute interval) Data Logging: 10 16-Bit Configurable (can include Date/Time) Data Buffers b Data Logging: 3 Timestamped 32-Bit Configurable Data Buffers b b Outputs Alarm Output (N.C.) b b b b b b b 1 Pulse Output (N.O.) b b b 2 Pulse Outputs (N.O.) b b RS-485 Serial (Modbus RTU Protocol) b b b RS-485 Serial (BACnet MS/TP Protocol) b b b b LON FT Serial (LonTalk Protocol) Inputs 2 Pulse Contact Accumulator Inputs b b 1 Pulse Contact Accumulator Input b b Display Screen Diagram Screen Name or Units Diagnostic Alert Numeric Data Alive Indicator Export Import Transmit Data Receive Data Receive Data Error 200 Version: 1.0 - 24/01/2020 PLSED309005EN_09 PB105436 RETROFIT PRODUCTS EM3500 series EM3500 dimensions DIMENSIONS AND CONNECTION PB105421 PB105420 PB105439 PB105417 Bottom View (DIN Mount Option) EM3500 connections Two 5-character rows of display text. Top row alphanumeric; Bottom row numeric only The red Alarm LED lights when any of the 3 phase voltages drop below the selected threshold. The green Energy LED lights momentarily each time the Energy output pulse is active. Please see EM3500 User Guide and EM3500 Installation Guide for safe and correct wiring and connection information. Version: 1.0 - 24/01/2020 PLSED309005EN_09 201 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS EM4200 series The PowerLogic EM4200 Series Enercept power and energy meters provide a unique solution for measuring energy data. Designed for simplicity, the range includes two main offers: System Calibrated and Flex. The EM4200 System Calibrated offers system accuracy, pre-mounted Current Transducers, with a simple to quote and order single part number. The EM4200 Flex offers the flexibility of a wide range of Current Transducers to match most applications, no matter how varied. Applications Capable of essential cost management: � Energy monitoring in building automation systems � Renewable energy monitoring � Energy management � Commercial sub-metering � Industrial monitoring � Accurate cost allocation PB120808 202 METSEEM4235 Version: 1.0 - 24/01/2020 PLSED309005EN_09 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS The solution for Markets that can benefit from a solution that includes PowerLogic EM4200 series: � Buildings � Industry � Healthcare � Data centre and networks � Infrastructure Benefits System integrators' benefit � Ease of integration � Ease of setup � Cost effectiveness Panel builders' benefit � Ease of installation � Cost effectiveness � Aesthetically pleasing � Simplified ordering End users' benefit � Ease of use � Precision metering & sub-billing � Billing flexibility � Comprehensive, consistent and superior performance Competitive advantages � High reliability with high system, or meter accuracy. � Single part to order a metering chain (System Calibrated). � Supports a large range of Sensor options. Flex can adapt to CTs from 50 to 5000 A, or different Rogowski coil sizes rated for up to 5000 A. � Modbus and BACnet protocols along with uni-directional and bi-directional feature sets. � Wide 90 to 480 V AC input range. � DIN rail or screw-mount options, including mounting bracket for easy installation. � Seamless integration with EcoStruxureTM Power Management software products. Power management solutions Schneider Electric provides innovative power management solutions to increase your energy efficiency and cost savings, maximise electrical network reliability and availability, and optimise electrical asset performance. Conformity of standards � CAN/CSA-C22.2 � EN 61326-1 � EN 61000-6-2 Class A � EN 61000-6-4 � FCC 47 CFR Class A Part 15 Class A � EN 61010-1 � UL 61010-1 Accuracy standards Flex models � ANSI C12.20-2015 Class 0.2 � IEC 62053-24 Class 1S When used with 1/3 V CT (Meter accuracy) � IEC 62053-22 Class 0.2S 0.2% When used with Rogowskil Coils (Meter accuracy) � IEC 62053-22 Class 0.5S System calibrated � ANSI C12.1, 1% � IEC 62053-22 Class 1S 1% Version: 1.0 - 24/01/2020 PLSED309005EN_09 203 PB120809 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS EM4200 series EM4200 Flex Power Meter EM4200 System Calibrated with calibrated Rogowski coils The EM4200 meter series provides a highly flexible retrofit option ideal when adding metering to an existing building, or to integrate in an OEM solution. Designed to simplify the ordering process, the meter is declined in 2 major options: System Calibrated offers the simplest way to order, deploy and meet requirements. The meter comes with pre-mounted Current Transducers (CT), or Rogowski Coils. A single reference provides a System calibrated accuracy meter with a 100, 200, 400A CT, or 5,000A Rogowski coil. Flex offers the flexibility required when the CT, or Rogowksi coil, rating or size needs to further adapt to the site. CTs can range from 50 to 5,000A and Rogowski coils can be different sizes with a 5,000 A rating. � General features �� Uni and Bi-Directional metering to support to power generation application. �� Data logging. �� Modbus and BACnet serial communication with auto-protocol and baud rate detection. �� Configurable with or without power. �� DIN rail or screw-mount options, including mounting brackets for easy installation. �� Seamless integration in Power Monitoring Operations and Power SCADA Operations. �� Wide input range of 90 to 480 V AC. �� Approvals: UL 61010-1, IEC/EN 61010-1 � System calibrated features �� Three factory mounted and calibrated Current Transducers (100, 200 or 400 A), or Rogowski coils (5,000 A, 12" or 18" (304.8 mm or 457.2 mm)). Simplifies ordering and commissioning. �� ANSI version only: Fuse packs factory mounted. �� System Accuracy from 1% to 100% load: �� Real Power and Energy: ANSI C12.1 1%, IEC 62053-22 Class 1S, 1%. �� Reactive Power and Energy: IEC 62053-24 Class 1, 1% � Flex features �� Supports generic 1/3 V CTs from 50 to 5,000 A. Or 1/3 V 5,000 A Rogowski coils. �� ANSI: Optional fuse packs available. �� Meter Accuracy from 1% to 100% of load (CT mode): �� Real Power and Energy: ANSI C12.20 0.2%, IEC 62053-22 Class 0.2S, 0.2%. �� Reactive Power and Energy: IEC 62053-24 Class 1, 1%. PB119361 204 Version: 1.0 - 24/01/2020 PLSED309005EN_09 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS EM4200 series EM4200 series selection guide Advantage EM4200 Flex METSEEM4235 METSEEM4236 General Market IEC ANSI Single part to order Factory mounted CTs/Rogowski coil CT Rating 50 to 5000 A user choice 50 to 5000 A user choice Rogowski Coil Type 1/3 V Solid or Split Core 1/3 V Solid or Split Core Rating 5000 A 5000 A Accuracy Fuse pack Communication Type Size User choice User choice Meter 0.2% with CTs 0.5% with Rogowski Coil System 0.2% with CTs 0.5% with Rogowski Coil Option sold separately Option sold separately EM4200 System Calibrated METSEEM4235Axx METSEEM4236Axx METSEEM4235Bxx METSEEM4236Bxx IEC ANSI IEC ANSI Yes Yes Yes Yes Yes Yes Yes Yes Three Three 100, 200 or Three 100, 200 or 400 A supplied 400 A supplied Split Core Split Core 5000 A supplied Three 5000 A supplied 12" or 18" 12" or 18" 1% 1% 1% 1% Factory mounted Factory mounted EM4200 parts descriptions and advantages EM4200 Flex meter EM4200 System calibrated PB120811 PB120812 Version: 1.0 - 24/01/2020 PLSED309005EN_09 205 RETROFIT PRODUCTS FUNCTIONS AND CHARACTERISTICS EM4200 series Electrical characteristics Input-voltage Inputs characteristics Measured voltage Frequency range Mechanical characteristics Weight Dimensions Environmental conditions Operating temperature Storage temperature Humidity rating Enclosure Altitude Pollution degree Electromagnetic compatibility Compliance Accuracy EM4200 Flex V1, V2, V3, Vn 90 - 277 V AC L-N UL max 480 V L-L CE max 300 V L-N 50/60 Hz Approx 1/0 kg (2.2 lb) 46.63 x 35.81 x 152.36 mm (1.84 x 1.41 x 6.0 in) -30 �C to 70 �C (-22 to 158 �F) -40 �C to 85 �C (-40 to 185 �F) <95 % RH non-condensing Indoor use only - not suitable for wet locations 3000 m (10,000 ft) 2 EM4200 System calibrated V1, V2, V3, Vn 90 - 277 V AC L-N UL max 480 V L-L CE max 300 V L-N 50/60 Hz 1.4 to 2.2 Kg (3.10 to 4.85 lb) (model dependent) 46.63 x 35.81 x 152.36 mm (1.84 x 1.41 x 6.0 in) (Meter alone), CT/ Rogowski size varies with model 0 to 70 �C (32 to 158 �F) With Split Core CTs: -40 to 85 �C (-40 to 185 �F) With Rogowski Coils: -40 to 70 �C (-40 to 158 �F)) <95 % RH non-condensing Indoor use only - not suitable for wet locations 3000 m (10,000 ft) 2 CAN/CSA-C22.2 EN 61000-6-2 EN 61000-6-4 Class A EN 61010-1 EN 61326-1 Class A FCC 47 CFR Part 15 Class A UL 61010-1 CAN/CSA-C22.2 EN 61000-6-2 EN 61000-6-4 Class A EN 61010-1 EN 61326-1 Class A FCC 47 CFR Part 15 Class A UL 61010-1 ANSI C12.20-2015 Class 0.2 ANSI C12.20-2015 Class 0.2 IEC 62053-24 Class 1S IEC 62053-24 Class 1S ANSI C12.20 2015 Class 0.2 IEC 62053-24 Class 1S When used with 1/3 V CT (Meter accuracy) IEC 62053-22 Class 0.2S 0.2% When used with Rogowski coils (Meter accuracy) IEC 62053-22 Class 0.5S ANSI C12.1 1% IEC 62053-21 Class 1S 1% IEC 62053-24 Class 1 1% Commercial Reference Numbers Market Commercial Reference IEC IEC IEC IEC IEC IEC ANSI ANSI ANSI ANSI ANSI ANSI METSEEM4235 METSEEM4235A12 METSEEM4235A18 METSEEM4235B101 METSEEM4235B201 METSEEM4235B401 METSEEM4236 METSEEM4236A12 METSEEM4236A18 METSEEM4236B101 METSEEM4236B201 METSEEM4236B401 Rating User choice Up to 5000 A (3 coils supplied) Up to 5000 A (3 coils supplied) 100 A (3 CTs supplied) 200 A (3 CTs supplied) 400 A (3 CTs supplied) User choice Up to 5000 A (3 coils supplied) Up to 5000 A (3 coils supplied) 100 A (3 CTs supplied) 200 A (3 CTs supplied) 400 A (3 CTs supplied) CTR type CT size Fuse pack CT lead length System calibrated Rogowski 12" (304.8 mm) 6 ft (1828.8 mm) Yes Rogowski 18" (457.2 mm) 6 ft (1828.8 mm) Yes Split core 6 ft (1828.8 mm) Yes Split core 6 ft (1828.8 mm) Yes Split core 6 ft (1828.8 mm) Yes Option Rogowski 12" (304.8 mm) Yes 6 ft (1828.8 mm) Yes Rogowski 18" (457.2 mm) Yes 6 ft (1828.8 mm) Yes Split core Yes 6 ft (1828.8 mm) Yes Split core Yes 6 ft (1828.8 mm) Yes Split core Yes 6 ft (1828.8 mm) Yes 206 Version: 1.0 - 24/01/2020 PLSED309005EN_09 RETROFIT PRODUCTS EM4200 series EM4200 dimensions DIMENSIONS AND CONNECTION PB115452 PB115454 PB115453 Version: 1.0 - 24/01/2020 PLSED309005EN_09 207 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Communications & Gateways This is a part of your metering solution which provides an interface between energy monitoring software and your metering points via GPRS, wired connection and Wi-Fi. We also offer the option of an integrated gateway-server which provides an all-in-one energy management solution. They are fully capable of supporting EcoStruxureTM Power Management software. Data loggers, gateways and remote terminal units help measured data reach the power monitoring software for analyses. They are fundamental components in most power and energy management system architectures. � � Link150 Ethernet gateway � � Data logger Com'X 210 � � Data logger Com'X 510 � � ION7550 RTU PB115427 PB112041 PE86117 EGX150 208 EBX210 P765CA0A Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Serial link With Schneider Electric's advanced communication technology, all forms of power monitoring data can be accessed remotely, quickly and easily. In all architectures, the communication interface serves as the link between the installation devices and the PC running the operating software. It provides the physical link and protocol adaptation. Adaptation is required because the communication systems used by the PC (Modbus via RS-232 and/or Ethernet) are generally not those used by the installation devices (e.g. the Modbus protocol via RS-485). Dedicated application software prepares the information for analysis under the best possible conditions. In addition, an Modbus-Ethernet gateway in serial port slave mode allows a serial Modbus master device to access information from other devices across a Modbus TCP/IP network. RS-232 - RS-485 interface Modbus master device Link150 serial slave mode Modbus communication architecture. Switchboard-data acquisition and monitoring make it possible to anticipate events. In this way, they reduce customer costs in terms of operation, maintenance and investment. Modbus communication across Ethernet network DB111316 DB111317 Version: 1.0 - 24/01/2020 PLSED309005EN_10 209 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Ethernet link Using modern web technologies, the operator can access information from monitoring and protection devices using any PC connected to the network, with all the required security. The Ethernet Modbus-Ethernet gateway* or the integrated gateway-servers* provide connectivity between Modbus RS-485 and Ethernet Modbus TCP/IP. PB11133a Link150 Com'X 510 Ethernet communication architecture. The services available with these technologies considerably simplify the creation, maintenance and operation of these supervision systems. The application software is now standardised: the web interface into the system does not require custom web pages to be created. It is personalised by simply identifying the components in your installation and can be used as easily as any internet application. The first step in this approach is the integrated gateway-server with HTTP pages. Power management software (EcoStruxureTM Power Monitoring Expert and EcoStruxureTM Power SCADA Operation), running on a PC, provide broader coverage for more specific need 210 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Link150 Ethernet gateway The Link150 gateway provides fast, reliable Ethernet connectivity in the most demanding applications, from a single building to a multi-site enterprise. This gateway supports meters, monitors, protective relays, trip units, motor controls and other devices that need to communicate data quickly and efficiently. It is your simple, cost-effective serial line to full Ethernet connectivity. Applications � Energy management � Power distribution � Building automation � Factory automation PB115427 Version: 1.0 - 24/01/2020 PLSED309005EN_10 EGX150 211 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS PB117745 The solution for All markets that can benefit from a solution that includes the Link150 gateway: � Buildings � Data centre � Healthcare � Industry � Infrastructure � Utility Benefits � Easy to install and setup � Easy to maintain � Advanced security feature � Compatible with Schneider Electric software offerings � Reliable Modbus to Ethernet protocol conversion Architecture PowerLogic software Energy and power management software Powerlogic software is recommended as a user interface which provides access to all status and measurement information. It also prepares summary reports for energy and power management. The Link150 is compatible with � EcoStruxureTM Power Monitoring Expert software � EcoStruxureTM Power SCADA Operation Conformity of standards � EN 55022/EN 55011/ � EN 61000-4-4 FCC Class A � EN 61000-4-5 � EN 61000-6-2 � EN 61000-4-6 � EN 61000-4-2 � EN 61000-4-8 � EN 61000-4-3 � EN 60950 Ethernet Modbus TCP/IP Link150 Modbus RS-485 serial link PM5000 PM8000 Micrologic Sepam Security � Secure user interface including user's name and password for login � Advanced security features to allow users to specify which Modbus TCP/IP master devices may access attached serial slave devices � Modbus TCP/IP filtering feature � Allows user to specify the level of access for each master device as Read-only or Full access � Web pages provide easy configuration and setup Commercial ref. no. EGX150 Product description Link150 Ethernet Gateway 212 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Link150 Ethernet gateway Technical specifications Weight Dimensions (HxWxD) Mounting Link150 175 g without packing 72 x 105 x 71 mm DIN rail Power-over-Ethernet (PoE) Class 3 Power supply 24 V DC (-20/+10 %) or Power over Ethernet (PoE Class 3 IEEE 802.3 af) at 15 W Consumption (typical) 24 V DC, 130 mA at 20 �C PoE 48 V DC, 65 mA at 20 �C Ambient operating temperature Ambient storage temperature -25 to 70 �C -40 to 85 �C Humidity rating 5 % to 95 % relative humidity (without condensation) at +55�C Pollution Degree Level 2 IP Ratings On the front panel (wall-mounted enclosure): IP4x Connectors: IP20 Other parts: IP30 Regulatory/standards compliance for electromagenetic interference Emissions (radiated and conducted) EN 55022/EN 55011/FCC class A Immunity for industrial environments: electrostatic discharge radiated RF electrical fast transients surge EN 61000-6-2 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 conducted RF EN 61000-4-5 power frequency EN 61000-4-6 magnetic field EN 61000-4-8 Regulatory/standards compliance for safety Safety - IEC Safety - ULg EMC Australia IEC 60950 UL 60950 UL 61010-2-201 IEC 6100-6-2 C-tick - RCM Sustainability Serial ports Green Premium Number of ports 2 (1 available at a time) Types of ports RS-232 or RS-485 (2-wire or 4-wire), depending on settings Protocol Modbus, Serial Baud rates 19200 bps (factory setting), 2400 bps, 4800 bps, 9600 bps, 38400 bps, 56000 bpsgg, 57600 bpsgg Maximum number of connected devices 32 (directly) 247 (indirectly) Ethernet ports (used as a switch) Number of ports 2 Type of port 10/100BASE-TX (802.3af) por Protocol HTTP, Modbus TCP/IP, FTP, SNMP (MIB II) g Dual listed for US and Canada gg Only available when Physical Interface is set to RS-232 and Transmission Mode is set to Modbus ASCII Version: 1.0 - 24/01/2020 PLSED309005EN_10 213 COMMUNICATIONS & GATEWAYS Link150 Ethernet gateway Parts A Ethernet 1 communication port B Ethernet 2 (PoE) communication port C Midspan PoE injector PB115432 DIMENSIONS AND CONNECTION D Ethernet communication LEDs E Module status LED F Network status LED G Sealable transparent cover H IP reset pin I RS-485 traffic status LED J Device soft restart button (Accesible through closed cover) K RS-232 traffic status LED L Device name label PB115431 PB115433 Dimensions M RS-232 port N RS-485 port DIN rail mounting PB115429 PB115430 PB115436 214 Fast and easy DIN rail installation See appropriate Installation Guide for this product. Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Com'X 210 A highly flexible plug-and-play Energy Server Com'X 210 collects and stores WAGES consumptions and environmental parameters such as temperatures, humidity and CO2 levels in a building. Data is periodically transmitted as a report to an internet database server for further processing. The Energy Server Com'X 210 not only reduces your technical complexity, but helps to manage your energy. Applications The quickest path to multi-site energy management and on-line services � Delivers batches of data ready to process by EcoStruxureTM Power Management solutions and services � Publishes logged data to the Schneider Electric cloud or another hosted platform PB112041 Version: 1.0 - 24/01/2020 PLSED309005EN_10 EBX210 215 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS The solution for All markets that can benefit from a solution that includes data logger Com'X 210: � Buildings � Industry Benefits � Data collection from up to 64 field devices � Data publishing leveraging existing infrastructures, Ethernet or Wi-Fi, GPRS-ready � Quick fitting into electrical switchboards thanks to DIN rail clipping and profile � Quick setup and configuration thanks to intuitive HMI Energy management solutions The data collected and stored by Com'X 210 can be processed and displayed as webpages through web services provided by Schneider Electric, such as EcoStruxureTM Power Management software products, or by any private energy platform. The Com'X 210 also provides a transparent interface between Ethernetbased networks and field devices. This gateway function supports the use of monitoring software, such as EcoStruxureTM Power Monitoring Expert (PME) for data collection, trending, event management, analysis and further processing. Conformity of standards � EN 60950 Architecture PB114856-200 216 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Data collector Collects and stores energy data from up to 64 field devices, connected to either: � Ethernet TCP/IP field network. � Modbus Serial line network (up to 32 devices). � Embedded digital and analogue inputs. "Field devices" consist of : � PowerLogic devices for power and energy monitoring. � Masterpact or Compact circuit-breakers for protection and monitoring. � Acti9 protection devices, meters, remote controlled switches, etc. � Water, Air, Gas, Electricity, and Steam (WAGES) consumption meters, from specialised manufacturers, delivering pulses as per standard (see table next page). � Environmental sensors such as temperatures, humidity, and CO2 levels in a building, providing analogue information. Data logging and storage capabilities include: � Configurable logging interval, from every minute to once a week. � Data storage duration of several weeks, depending on quantity of collected data. Data publisher Batches of collected data periodically transmitted to an Internet server, as: � XML files, for processing by EcoStruxureTM Power Management software products. � CSV files for viewing in Excel or transformed for upload into programs such as EcoStruxureTM Power Monitoring Expert or any compatible software. Data publishing function supports 4 transfer protocols over Ethernet or Wi-Fi: � HTTP � FTP � HTTPS � SMTP Additional functions Gateway If selected by the user, the Com'X 210 can also make all data from connected devices available in real-time: � In Modbus TCP/IP format over Ethernet or Wi-Fi. � For requests by an energy management software. Modbus packets can be sent from managing software to field devices through Modbus serial line or Modbus TCP/IP over Ethernet. Commercial ref. no. EBX210 EBXA-ANT-5M Product description Com'X 210 data logger 24 V DC or 230 V AC power supplied Com'X External GPRS antenna Version: 1.0 - 24/01/2020 PLSED309005EN_10 217 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Com'X 510 A highly flexible plug-and-play Energy Server Com'X 510 collects and stores WAGES consumptions and environmental parameters such as temperatures, humidity and CO2 levels in a building. The Com'X 510 has up to 2 year data storage and embedded webpages which means all your energy data can be viewed and managed on-site. Applications � All-in-one-box energy management solution especially suitable for buildings up to 10,000 sq. metres PB114582 218 EBX510 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS The solution for All markets that can benefit from a solution that includes data logger Com'X 510: � Buildings � Industry Benefits � Data collection from up to 64 field devices � Data publishing leveraging existing infrastructures : Ethernet or Wi-Fi, GPRS-ready � Quick fitting into electrical switchboards thanks to DIN rail clipping and profile. � Quick setup and configuration thanks to intuitive HMI Competitive advantages � Fit any PDU or RPP design for both new and retrofit projects � Class 1.0 system accuracy � Ethernet communication Energy management solution The data collected and stored by Com'X 510 can be processed and displayed through its own onboard webpage. The Com'X 510 also provides a transparent interface between Ethernetbased networks and field devices. This gateway function supports the use of monitoring software, such as EcoStruxureTMPower Monitoring Expert for data collection, trending, event management, analysis and further processing. Conformity of standards � EN 60950 Architecture PB114856 Version: 1.0 - 24/01/2020 PLSED309005EN_10 219 PB114852 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Com'X 510 Energy server Energy dashboard comparing accumulated over time energy values (partial screen) Data collector As soon as the data logger is connected to the LAN, it can be detected and assigned an IP address by DHCP. Your operating system's DPWS feature allows your computer to automatically recognise the device as Com'X. Embedded web pages are then immediately accessible by clicking each Com'X device icon or by typing the assigned IP address into your web browser. Collects and stores energy data from up to 64 field devices, connected to either: � Ethernet TCP/IP field network. � Modbus Serial line network (up to 32 devices). � Embedded digital and analogue inputs. "Field devices" consist of: � PowerLogic meters for power and energy monitoring. � Masterpact, Powerpact, or Compact circuit-breakers for protection and monitoring. � Acti9 protection devices, meters, remote controlled switches, etc. � Water, Air, Gas, Electricity, and Steam (WAGES) consumption meters, from specialised manufacturers, delivering pulses as per standard (see table at end of this document). � Environmental sensors such as temperatures, humidity, and CO2 levels in a building, providing analogue information. Data logging and storage capabilities include: � Data logging period: configurable from every minute to once a week. � Data storage duration: up to 2 years, depending on quanitity of collected data. � Able to set time and send reset instructions to field devices. Embedded energy management software The Com'X provides the end-user with immediate visibility into energy consumption throughout the site. As soon as the Com'X is connected to the Local Area Network (LAN), several web pages are accessible via any standard web browser, (without plug-in or additional components). These web pages display real-time data as it is collected, in easy to understand tabular and summary formats. In addition, users can get simple analysis of historical data in bar graph or trending formats. 220 Version: 1.0 - 24/01/2020 PLSED309005EN_10 PB114327 PB114854 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Com'X 510 Energy server Energy Server Com'X 510 data logger Raw data and measurements from one field device (partial screen) Additional functions Data publisher Batches of collected data can also be periodically transmitted to an Internet server, as: � XML files, for processing by EcoStruxureTM Power Management software products � CSV files for viewing in Excel or transformed for uploading to programs such as EcoStruxureTM Power Monitoring Expert or any compatible software Data publishing function supports 4 transfer protocols over Ethernet or Wi-Fi: � HTTP � HTTPS � FTP � SMTP Gateway � If selected by the user, the Com'X 510 can make data from connected devices available in real time � In Modbus TCP/IP format over Ethernet or Wi-Fi � For requests by energy management software Modbus packets can be sent from managing software to field devices through Modbus serial line or Modbus TCP/IP over Ethernet. Commercial reference numbers Description EBX510 Com'X 510 energy server 24 V DC power supplied UL rated EBXA-ANT-5M Com'X External GPRS antenna EBXA-USB-Zigbee Com'X Zigbee USB interface Historical trending comparing multiple devices or multiple topics (partial screen) PB114853 Version: 1.0 - 24/01/2020 PLSED309005EN_10 221 PB112047 PB114859 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Com'X 210/510 Data Logger Connection points 1 Terminal block 2 RJ45 cable 3 Ethernet port #1 4 Ethernet port #2 Power supply to analogue and digital inputs GPRS modem GPRS antenna Connectivity � Modbus SL / RS-485 connections to field devices �� By cable with RJ45 connector. � 2 Ethernet ports �� Used to either separate upstream connection from field devices network or to daisy chain Ethernet devices. �� RJ45 10/100BASE connectors. �� Static IP address. � Ethernet port #1 �� Connection to Local Area Network (LAN). �� PoE Class 3 (802.3af) can act as main/backup power supply for the Com'X. �� DHCP client. � Ethernet port # 2 �� Connection to field devices. �� DHCP client or server. � Power supply to analogue and digital outputs �� Outputs to supply sensors and inputs when Com'X is supplied through 24 V DC input on top: �� 12 V DC 60 mA for digital inputs. �� 24 V DC for analogue inputs. �� Compliant with electrical switchboard environment (temperature, electromagnetic compatibilty). � 2 inputs for analogue sensors �� PT100 or PT1000 temperature probes. �� Various sensors (humidity, CO2, etc.) with 0-10 V output. �� Various sensors with 4-20 mA output � 6 inputs for dry contact sensors or pulse counters �� Max 25 pulses per second (min duration 20 ms) �� IEC 62053-31 Class A � GPRS modem �� For connection to the data processing server through cellular or user's APN network. �� Also connect to Schneider Electric's Digital Service Platform. �� Especially suitable for sites with no internet access. �� Simply plugs into dedicated port under the front cover. � GPRS antenna �� Improves GPRS signal strength in case of poor transmission conditions. �� Recommended for Com'X located inside metallic electrical panels. PB112042 PB112045 222 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Com'X 210/510 setup and configuration Setup and configuration Connection to LAN As soon as they are connected to the LAN, Com'X devices can be detected and assigned an IP address by DHCP. Your operating system's DPWS feature allows your computer to automatically recognise the device as Com'X. Embedded web pages are then immediately accessible by clicking each Com'X device icon or by typing the assigned IP address into your web browser. Field device auto-discovery Data selection for logging and publication The user-activated device discovery function automatically identifies all field devices connected to Modbus SL, Ethernet port. Web page configuration tabs allow you to configure, in just a few clicks, which connected field devices collect and publish data. � Schneider Electric devices display with the product image. � Other devices appear as "unknown," allowing the user to manually assign a device type. � User can assign their own device types. � Users can complete additional device identification fields, such as circuit ID or building zone. � Advanced diagnostics and troubleshooting features � Modbus serial and TCP/IP device statistics. � Ethernet network statistics. � Communications check wizard. � Direct reading of register values from local and remote devices. PB114857 Additional features and benefits � Cybersecurity - works well with your cyber security architecture. � 2 Ethernet ports to separate upstream cloud connection, or to daisy chain with other Ethernet devices, from field device network. � Data storage in case of communications failure. � Local backup of configuration parameters - back up your system to a USB storage device and have it available for system restore or to duplicate the configuration on another box. Com'X 210/510 installation Device settings page (partial), as displayed after autodiscovery, enabling user to assign circuit identifications and select data for logging and publication. PB118056 PB118057 DIN rail fitting (Front face IP40, terminals IP20). Version: 1.0 - 24/01/2020 PLSED309005EN_10 223 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS Com'X 210/510 Data Logger Technical specifications Com'X 210/510 Environment Operating temperature Storage temperature GPRS dongle Operating temperature -25� to 60�C Com'X 210 -25� to 70�C Com'X 510 -40� to 85�C -20� to 60�C GPRS dongle Storage temperature -40� to 85�C Wif-Fi dongle Operating temperature Wi-Fi dongle Storage temperature Humidity Pollution Safety standards / regulation International (CB scheme) 0� to 50�C -20� to 80�C 5 to 95 % relative humidity (without condensation) at 55�C Class III IEC 60950 USA UL 508 USA Canada Canada Europe Quality Brands Power Supply AC DC Power over Ethernet Max power Mechanical IP Dimensions (HxWxD) Weight UL 60950 (Com'X 510 only) cUL 60950 (Com'X 510 only) cULus 508 EN 60950 CE, UL 100-230 V (+/- 15%)(50-60 Hz) 24 V (+/- 10%) 15.4 W DC 26 W max Front face IP40, terminals IP20 91 x 144 x 65.8 mm 450 g Com'X 210 b b b b Com'X 210 b b b Com'X 510 b b b Com'X 510 b b b 224 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS ION7550 RTU The PowerLogic ION7550 RTU (remote terminal unit) is an intelligent web-enabled device ideal for combined utilities metering of water, air, gas, electricity and steam (WAGES). When combined with Power management software, the ION7550 RTU offers a seamless, end-to-end WAGES metering solution. Featuring a large, high-visibility display and overall versatility of the PowerLogic system, the ION7550 RTU provides extensive analogue and digital I/O choices and is a cost-effective dedicated WAGES solution when compared to a traditional meter. The device automatically collects, scales and logs readings from a large number of connected meters or transducers and delivers information to one or more head-end systems through a unique combination of integrated Ethernet, modem or serial gateways. Applications � WAGES (water, air, gas, electricity, steam) metering � Integrated utility metering with advanced programmable math functions � Data concentration through multi-port, multi-protocol communications � Equipment status monitoring and control � Programmable set points for out-of-limit triggers or alarm conditions PE86117 Version: 1.0 - 24/01/2020 PLSED309005EN_10 P765CA0A 225 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS The solution for All markets that can benefit from a solution that includes PowerLogic ION7550 RTU series meters: � Buildings � Industry � Healthcare � Education � Etc. Benefits � Help reduce waste and optimise equipment operation to increase energy efficiency � A large, intuitive display � Extensive digital and analogue I/O � Dedicated WAGES solution when compared to a traditional meter Competitive advantages � Data concentration through multi-port, multi-protocol communications � Integrated utility metering with advanced programmable function Power management solutions As part of a complete enterprise energy management solution, the ION7550 RTU can be integrated with EcoStruxureTM Power Monitoring Expert, or other SCADA, information and automation systems. Conformity of standards � EN 61010-1 � IEC 61000-4-2 � IEC 61000-4-3 � IEC 61000-4-4 � IEC 61000-4-5 � CISPR 22 Main characteristics � Increase efficiency �� Reduce waste and optimise equipment operation to increase efficiency. � Easy to operate �� Screen-based menu system to configure meter settings. Bright LCD display with adjustable contrast. � Integrate with software �� Easily integrated with PowerLogic or other energy management enterprises, including SCADA systems. � Transducer and equipment condition monitoring �� Versatile communications, extensive I/O points, clock synchronisation, event logging and sequence of events recording capabilities for transducer and equipment condition and status monitoring at utility substations. � Set automatic alarms �� Alarm setpoint learning feature for optimum threshold settings. � Up to 10 Mbytes of memory �� For archiving of data and waveforms. � Notify alarms via email �� High-priority alarms sent directly to the user's PC. Instant notification of power quality events by email. � Modbus Master functionality �� Aggregate and store data from downstream Modbus devices using serial or Ethernet connections 226 Version: 1.0 - 24/01/2020 PLSED309005EN_10 PE86124 COMMUNICATIONS & GATEWAYS ION7550 RTU M5 4 N 9 PowerLogic� ION7550 RTU. 1 I/O expansion card. 2 Digital inputs. 3 Analogue inputs. 4 Analogue outputs. 5 Communications card. 6 Power supply. 7 Form C digital outputs. 8 Digital inputs. 9 Form A digital outputs. FUNCTIONS AND CHARACTERISTICS Part numbers Item 1 Model 2 Form Factor 3 RTU option 4 Power Supply 5 Internal use Code Description 7550 ION7550 device A0 Integrated display with front optical port, 5 MB logging memory, and 512 samples/cycle resolution. B0 Integrated display with front optical port, 10 MB logging memory, and 512 samples/cycle resolution. T0 Transducer (no display) version, with 5 MB logging memory. U0 Transducer (no display) version, with 10 MB logging memory. N9 RTU option B Standard power supply (85-240 VAC, �10%/47-63 Hz / 110-330 VDC, �10%) C Low voltage DC power supply (20-60 VDC) 9 This field for internal use only Standard communications (1 RS-232/RS-485 port, 1 RS- A0 485 port). Integrated display models also include 1 ANSI Type 2 optical communications port. 6 Communications 7 I/O 8 Security 9 Special Order Standard communications plus 10BASE-T/100BASE-TX C1 Ethernet (RJ-45), 56k universal internal modem (RJ-11). Ethernet, modem gateway functions each use a serial port. Standard comms plus 10BASE-T/100BASE-TX Ethernet D7 (RJ-45) and 100BASE-FX Ethernet Fiber, 56k universal internal modem (RJ-11). Ethernet and modem gateway functions each use a serial communications port. Standard communications plus 10BASE-T/100BASE-TX E0 Ethernet (RJ-45). Ethernet gateway function uses serial port. Standard communications plus 10BASE-T/100BASEF1 TX Ethernet (RJ-45) and 100BASE-FX (SC fiber optic connection). Ethernet gateway uses a serial port. Standard communications plus 56k universal internal M1 modem (RJ-11). Modem gateway uses serial communications port. A Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs) E Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analogue inputs) K Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analogue outputs) Standard I/O plus Expansion I/O card (8 additional digital N inputs & four 0 to 20 mA analogue inputs and four 0 to 20 mA outputs) Standard I/O plus Expansion I/O card (8 additional digital P inputs & four 0 to 1 analogue inputs and four -1 to 1 mA analogue outputs) 0 Password protected, no hardware lock A None C Tropicalisation treatment applied Version: 1.0 - 24/01/2020 PLSED309005EN_10 227 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS ION7550 RTU Commercial ref. no. P765CA0A P765CA0C P765CC1A Communication Card for ION7550RTU Standard Comms: 1 RS-232/RS-485 port (COM1), 1 RS-485 port (COM2), Front optical port (COM3) Standard Comms: 1 RS-232/RS-485 port (COM1), 1 RS-485 port (COM2), Front optical port (COM3), tropicalisation treatment applied Standard plus Ethernet (10/100BASE-T), 56k universal internal modem (RJ11; shares COM3) P765CC1C Standard plus Ethernet (10/100BASE-T), 56k universal internal modem (RJ11; shares COM3), tropicalisation treatment applied P765CD7A Standard plus Ethernet (10/100BASE-T, 100BASE-FX), 56k internal modem (RJ11) P765CD7C Standard plus Ethernet (10/100BASE-T, 100BASE-FX), 56k internal modem (RJ11), tropicalisation treatment applied P765CE0A Standard plus Ethernet (10/100BASE-T) P765CE0C Standard plus Ethernet (10/100BASE-T), tropicalisation treatment applied P765CF1A Standard plus Ethernet (10/100BASE-T, 100BASE-FX) P765CF1C Standard plus Ethernet (10/100BASE-T, 100BASE-FX), tropicalisation treatment applied P765CM1A Standard plus 56k universal internal modem (RJ11; shares COM3) P765CM1C Standard plus 56k universal internal modem (RJ11; shares COM3),tropicalisation treatment applied Commercial ref. no. Analogue I/O cards P760AEA four 0 to 20 mA analogue inputs & 8 digital inputs P760AEC four 0 to 20 mA analogue inputs & 8 digital inputs,tropicalisation treatment applied P760AKA four 0 to 20 mA analogue outputs & 8 digital inputs P760AKC four 0 to 20 mA analogue outputs & 8 digital inputs,tropicalisation treatment applied P760ANA four 0 to 20 mA analogue inputs, four 0 to 20 mA analogue outputs & 8 digital inputs P760ANC four 0 to 20 mA analogue inputs, four 0 to 20 mA analogue outputs & 8 digital inputs,tropicalisation treatment applied P760APA four 0 to 1 analogue inputs, four -1 to 1 mA analogue outputs & 8 digital inputs. P760APC four 0 to 1 analogue inputs, four -1 to 1 mA analogue outputs & 8 digital inputs,tropicalisation treatment applied 228 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS ION7550 RTU Commercial ref. no. 70LRCK16-48 72-MOD-4000 72-ETH-T000 PS-240-15W Commercial ref. no. 70L-IAC 70L-IACA 70L-IDC 70L-IDCB 70L-IDCNP 70L-IDC5S 70L-ISW 70L-OAC 70L-OACL 70L-OACA 70L-OACAL 70L-ODC 70L-ODCA 70L-ODCB 70L-ODC5R Ordering reference 73L-II020 73L-II420 73L-ITCJ 73L-ITCK 73L-ITCT 73L-ITR100 73L-ITR3100 73L-ITR4100 73L-IV1 73L-IV10 73L-IV10B 73L-IV100M 73L-IV5 73L-IV5B 73L-IV50M 73L-OI020 73L-OI420 73L-OV10 73L-OV10B 73L-OV5 73L-OV5B OpenDAC rack, controllers, power supply OpenDAC rack. Holds up to 8 OpenLine modules to provide up to 16 I/O points. Requires communications controller OpenDAC OpenDAC RS-485 serial module. Communications controller for use in a Modbus RTU network. Supports up to 2 70LRCK16-48 OpenDAC racks OpenDAC Ethernet network module for use on an Modbus/TCP Ethernet network. Supports up to 2 OpenDAC racks 85-264 V AC/110-370 V DC 15 W power supply. Required for applying power to the racks and controllers OpenLine digital I/O modules digital input, 120 V AC digital input, 220 V AC digital input, 3-32 V DC digital input, fast switching digital input, 15-32 V AC/10-32 V DC dry contact closure-sensing DC input input test module digital output, 120 V AC digital output, 120 V AC inductive loads digital output, 220 V AC digital output, 220 V AC inductive loads digital output, 3-60 V DC fast digital output, 4-200 V DC digital output, fast switching digital output, dry contact OpenLine analogue I/O modules analogue input, current, 0-20 mA analogue input, current, 4-20 mA analogue input, temperature, J-type TC analogue input, temperature, K-type TC analogue input, temperature, T-type TC analogue input, temperature, RTD analogue input, temperature, 3wire RTD analogue input, temperature, 4wire RTD analogue input, voltage, 0-1 V DC analogue input, voltage, 0-10 V DC analogue input, voltage, -10 to 10 V DC analogue input, voltage, 0-100 V DC analogue input, voltage, 0-5 V DC analogue input, voltage, -5 to 5 V DC analogue input, voltage, 0-50 mV analogue output, current, 0-20 mA analogue output, current, 4-20 mA analogue output, voltage, 0-10 V DC analogue output, voltage, -10 to 10 V DC analogue output, voltage, 0-5 V DC analogue output, voltage, -5 to 5 V DC Version: 1.0 - 24/01/2020 PLSED309005EN_10 229 COMMUNICATIONS & GATEWAYS ION7550 RTU Features Data recording Min/max of instantaneous values Data logs Event logs Trending SER (Sequence of event recording) Time stamping GPS synchronisation (1 ms) Memory (in Mbytes) Display and I/O Front panel display Pulse output Digital or analogue inputs(max) Digital or analogue outputs (max, including pulse output) Communication RS-485 port RS-485 / RS-232 port Optical port Modbus TCP Master / Slave (Ethernet port) Modbus RTU Master / Slave (Serial port) Ethernet port (Modbus/TCP/IP protocol) Ethernet gateway (EtherGate) Alarms (optional automatic alarm setting Alarm notification via email (Meterm@il) HTML web page server (WebMeter) Internal modem Modem gateway (ModemGate) DNP 3.0 through serial, modem, and I/R ports FUNCTIONS AND CHARACTERISTICS ION7550 RTU b b b b b b b 10 b 1 24 30 1 1 1 b / b b / b 1 1 b b b 1 b b 230 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS ION7550 RTU Electrical characteristics Data update rate 1/2 cycle or 1 second AC 85-240 V AC �10% (47-63 Hz) DC 110-300 V DC �10% Power supply DC low voltage (optional) 20-60 V DC �10% Ride-through time 100 ms (6 cycles at 60 Hz) min. at 120 V DC Burden Standard: typical 15 VA, max 35 VA Low voltage DC: typical 12 VA, max 18 VA Input/outputs(1) Standard 8 digital inputs (120 V DC) 3 relay outputs (250 V AC / 30 V DC) 4 digital outputs (solid state) Optional 8 additional digital inputs 4 analogue outputs, and/or 4 analogue inputs Mechanical characteristics Weight 1.9 kg IP degree of protection (IEC60529) IP52 Dimensions Standard model TRAN model 192 x 192 x 159 mm 235.5 x 216.3 x 133.1 mm Environmental conditions Operating temperature Standard power supply Low voltage DC supply -20 to 70�C -20 to 50�C Display operating range -20 to 70�C Storage temperature Display, TRAN -40 to 85�C Humidity rating 5 to 95 % non-condensing Installation category III (2000 m above sea level) Dielectric withstand As per EN61010-1, IEC 62051-22A(2) Electromagnetic compatibility Electrostatic discharge IEC 61000-4-2 Immunity to radiated fields IEC 61000-4-3 Immunity to fast transients IEC 61000-4-4 Immunity to surges IEC 61000-4-5 Conducted and radiated emissions CISPR 22 Safety Europe IEC 61010-1 (1) Consult the ION7550 / ION7650 installation guide for complete specifications. (2) IEC 62051-22B with serial ports only. FUNCTIONS AND CHARACTERISTICS Version: 1.0 - 24/01/2020 PLSED309005EN_10 231 COMMUNICATIONS & GATEWAYS FUNCTIONS AND CHARACTERISTICS ION7550 RTU Communication RS-232/RS-485 port (1) Up to 115,200 bauds (57,600 bauds for RS-485), ION, DNP 3.0, Modbus, GPS, EtherGate, ModemGate, Modbus Master RS-485 port (1) Infrared port(1) Ethernet port Fibre-optic Ethernet link Protocol EtherGate ModemGate WebMeter Firmware characteristics High-speed data recording Up to 115,200 bauds, ION, DNP 3.0, Modbus, GPS, EtherGate, ModemGate, Modbus Master ANSI type 2, up to 19,200 bauds, ION, Modbus, DNP 3.0 10BASET, 100BASETX. RJ45 connector, 10/100 m link 100BASE FX, SC duplex connector, 1300 nm, FO multimode with gradient index 62.5/125 �m or 50/125 �m, 2000 m link ION, Modbus, Modbus Master, TCP/IP, DNP 3.0, Telnet Communicates directly with up to 62 slave devices via available serial ports Communicates directly with up to 31 slave devices 5 customisable pages, new page creation capabilities, HTML/XML compatible Down to 5 ms interval burst recording, stores detailed characteristics of disturbances or outages. Trigger recording by a user-defined setpoint, or from external equipment. Load profiling Trend curves Alarms Advanced security Memory Firmware update Display characteristics Integrated display Languages Channel assignments (800 channels via 50 data recorders) are configurable for any measurable parameter. Trigger recorders based on time interval, calendar schedule, alarm/event condition, or manually. Access historical data at the front panel. Display, trend and continuously update historical data with date and timestamps for up to four parameters simultaneously. Threshold alarms: adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm user-defined priority levels boolean combination of alarms is possible using the operators NAND, OR, NOR and XOR Up to 16 users with unique access rights. Perform resets, time syncs, or meter configurations based on user privileges 5 to 10 MB (specified at time of order) Update via the communication ports Backlit LCD, configurable screens English (1) All the communication ports may be used simultaneously. 232 Version: 1.0 - 24/01/2020 PLSED309005EN_10 COMMUNICATIONS & GATEWAYS ION7550 RTU ION7550 RTU dimensions DIMENSIONS AND CONNECTION PE86023 PE86022 PE86027 Front-panel mounting PE86123 Power supply Protection (3A) Fuse for N/- required if neutral is ungrounded Power supply L/+ N/- Connect G terminal to ground for AC power source Note: the current and voltage terminal strip (I52, I51, I42, I41, I32, I31, I22, I21, I12, I11, V4, V3, V2, V1, Vref) is not present on the RTU. Version: 1.0 - 24/01/2020 PLSED309005EN_10 233 INSULATION MONITORING DEVICES FUNCTIONS AND CHARACTERISTICS Insulation monitoring devices An IT earthing system allows your electrical distribution system to continually operate, even in the presence of an insulation fault, without endangering people or property. Required as part of an IT earthing system, an insulation monitoring device (IMD) detects the initial fault so you can make repairs before a second fault occurs, which could trigger protective devices and halt operations. PB118026 PB118027 PB118026 234 Version: 1.0 - 24/01/2020 PLSED309005EN_11 INSULATION MONITORING DEVICES FUNCTIONS AND CHARACTERISTICS Insulation Monitoring of IT / Ungrounded Networks Unlike the TT or TN earthing systems, the neutral of the transformer is isolated from the ground for an IT earthing system (also called Ungrounded system). PB118029 PB118030 PB118031 The main interest of IT systems is that in case of one insulation fault, no trip of protective device is required as the faulty current remains low. 230 V �� Advantages of IT networks include: �� Enhanced continuity of service of the network (no trip if there is one insulation fault on the network). �� Reduced risk of electric shock. �� Reduced risk of fire or explosion (low faulty current in case of insulation fault). 230 V �� Reduced stress on the network and increased equipment life (low faulty current in case of insulation fault). �� In a situation with several insulation faults, the faulty current is no longer negligible and will cause trip of the protections. �� For this reason, Insulation Monitoring Devices are used on IT networks in order to detect a first insulation fault and indicate its location so that the fault can be repaired; hence avoiding situations with several insulation faults and maintaining the continuity of service on the network. TT 110 V 110 mA IT 0.7 V < 1 mA Example of simple insulation monitoring system Version: 1.0 - 24/01/2020 PLSED309005EN_11 235 INSULATION MONITORING DEVICES FUNCTIONS AND CHARACTERISTICS Insulation Monitoring of IT / Ungrounded Networks IT earthing systems are used for applications requiring continuity of service, such as: �� Healthcare: critical rooms in medical premises such as operating theaters, intensive care units, recovery rooms. �� Industry: critical processes in cement, steel, chemical factories, food processing, car manufacturing, water, and waste water. �� Infrastructure: control tower and take-off path in airports, lighting, and signaling networks in rail. �� Utilities: power plants and control command systems. �� Photovoltaic: solar farms. �� Marine: electrical distribution of any type of ship. �� DC applications such as electrical vehicle charging stations. The Vigilohm catalog offers a range of products suitable for these various applications, from the simplest insulation monitoring systems to the most advanced ones, including individual insulation monitoring per feeder and communication with supervision. Example of Healthcare network monitored by Vigilohm Insulation Monitoring Devices in compliance with IEC 60364-7-710. Maintenance Room PME Operating Theater 1 Operating Theater 2 OTD Modbus TCP/IP Smartlink Ethernet OTD IM20H Link150 Smartlink Modbus IM20H IFL12H IFL12H Medical staff is informed of electrical faults in the operating theater room through the local HMI (Operating Theater Display - OTD) Technical staff is informed of any fault in the various operating theaters via a supervision system such as EcoStruxure Power Monitoring Expert. PB118032 Modbus RS485 Modbus RS485 236 Version: 1.0 - 24/01/2020 PLSED309005EN_11 PB118033 INSULATION MONITORING DEVICES FUNCTIONS AND CHARACTERISTICS Vigilohm Range Overview for Industrial Networks A simple range to meet your needs Industrial networks Monitoring and Control Power Monitoring & SCADA system Communication and Simple Monitoring Gateway, Data logger & Web Server Insulation Monitoring Devices Gateway, Data logger & Web Server Insulation Fault Locators Indentification of the faulty feeder Toroids Used along with the Fault Locators Version: 1.0 - 24/01/2020 PLSED309005EN_11 237 INSULATION MONITORING DEVICES FUNCTIONS AND CHARACTERISTICS Vigilohm Range Overview for Healthcare Dedicated offers for critical rooms compliant with IEC60364-7-7 10 Monitoring and Control Power Monitoring & SCADA system PB118034 238 Communication Gateway Local Displays HMI in the medical room Local Displays HMI in the medical room Insulation Fault Locators Identification of the fault Toroids Used along with the Fault Locators Version: 1.0 - 24/01/2020 PLSED309005EN_11 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS PowerLogic Commercial Reference Numbers Commercial ref. no. 16550 16551 16552 16553 METSECT5CC004 METSECT5CC005 METSECT5CC006 METSECT5CC008 METSECT5CC010 METSECT5CC013 METSECT5CC015 METSECT5CC020 METSECT5CC025 METSECT5MB025 METSECT5MB030 METSECT5MB040 METSECT5MA015 METSECT5MA020 METSECT5MA025 METSECT5MA030 METSECT5MA040 METSECT5MC025 METSECT5MC030 METSECT5MC040 METSECT5MC050 METSECT5MC060 METSECT5MC080 METSECT5MD050 METSECT5MD060 METSECT5MD080 METSECT5CYL1 METSECT5CYL2 METSECT5COVER METSECT5VV500 METSECT5VV600 METSECT5DA040 METSECT5DA050 METSECT5DA060 METSECT5DA080 METSECT5DA100 METSECT5DA125 METSECT5DA150 METSECT5DB100 METSECT5DB125 METSECT5DB150 METSECT5DB200 METSECT5DB250 METSECT5DB300 METSECT5DC200 METSECT5DC250 METSECT5DC300 METSECT5DC400 METSECT5DD100 METSECT5DD125 METSECT5DD150 Description Page Current Transformers 14 CT Ip/5 A ratio 15 44 x 66 x 37 Adapter for DIN rails Mounting plate 56 x 84 x 60 Adapter for DIN rails Mounting plate, insulated locking screw 56 x 84 x 60 Adapter for DIN rails Mounting plate Insulated locking screw sealable cover 77 x 107 x 64 Adapter for DIN rails Mounting plate Insulated locking screw CC 40 A CC 50 A CC 60 A CC 75 A CC 100 A CC 125 A CC 150 A CC 200 A CC 250 A MB 250 A MB 300 A MB 400 A MA 150 A MA 200 A MA 250 A MA 300 A MA 400 A MC 250 A MC 300 A MC 400 A MC 500 A MC 600 A MC 800 A MD 500 A MD 600 A MD 800 A Cylinder 8.5 mm dia. Cylinder 10.5 mm dia. sealable cover 60.5 x 22 x 23.5 mm for CT TI CT tropicalised 5000 5 bars 55x165 CT tropicalised 6000 5 bars 55x165 CT tropicalised 400 5 dual out. bars 32x65 CT tropicalised 500 5 dual out. bars 32x65 CT tropicalised 600 5 dual out. bars 32x65 CT tropicalised 800 5 dual out. bars 32x65 CT tropicalised 1000 5 dual out. bars 32x65 CT tropicalised 1250 5 dual out. bars 32x65 CT tropicalised 1500 5 dual out. bars 32x65 CT tropicalised 1000 5 dual out. bars 38x127 CT tropicalised 1250 5 dual out. bars 38x127 CT tropicalised 1500 5 dual out. bars 38x127 CT tropicalised 2000 5 dual out. bars 38x127 CT tropicalised 2500 5 dual out. bars 38x127 CT tropicalised 3000 5 dual out. bars 38x127 CT tropicalised 2000 5 dual out. bars 52x127 CT tropicalised 2500 5 dual out. bars 52x127 CT tropicalised 3000 5 dual out. bars 52x127 CT tropicalised 4000 5 dual out. bars 52x127 CT tropicalised 1000 5 dual out. bars 34x84 CT tropicalised 1250 5 dual out. bars 34x84 CT tropicalised 1500 5 dual out. bars 34x84 Commercial ref. no. METSECT5DE100 METSECT5DE125 METSECT5DE150 METSECT5DE200 METSECT5DH125 METSECT5DH150 METSECT5DH200 METSECTR30500 METSECTR46500 METSECTR60500 METSECTR90500 METSECTV25006 METSECTV25010 METSECTV25013 METSECTV25016 METSECTV35006 METSECTV35010 METSECTV35012 METSECTV35013 METSECTV35015 METSECTV35016 METSECTV35020 METSECTV35025 METSECTV45025 METSECTV45030 METSECTV45040 METSECTV45050 METSECTV45060 METSECTV45063 METSECTV29006 METSECTV29010 METSECTV29012 METSECTV29013 METSECTV29015 METSECTV29016 METSECTV29020 METSECTV70080 METSECTV70100 METSECTV70125 16029 16030 16031 16032 16033 16034 16035 16036 16037 16038 16039 Description Page CT tropicalised 1000 5 dual out. bars 54x102 CT tropicalised 1250 5 dual out. bars 54x102 CT tropicalised 1500 5 dual out. bars 54x102 CT tropicalised 2000 5 dual out. bars 54x102 CT tropicalised 1250 5 dual out. bars 38x102 CT tropicalised 1500 5 dual out. bars 38x102 CT tropicalised 2000 5 dual out. bars 38x102 Rogowski CTs 30 Rogowski CT, 250 mm core length, 96 mm dia. Rogowski CT, 250 mm core length, 146 mm dia. Rogowski CT, 250 mm core length, 191 mm dia. Rogowski CT, 250 mm core length, 287 mm dia. 0.333 V 3-in-1 CTs with RJ45 for PM53xR LVCT SolidC 3in1 RJ45 25mmCtr 60A:1/3V LVCT SolidC 3in1 RJ45 25mmCtr 100A:1/3V LVCT SolidC 3in1 RJ45 25mmCtr 125A:1/3V LVCT SolidC 3in1 RJ45 25mmCtr 160A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 60A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 100A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 120A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 125A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 150A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 160A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 200A:1/3V LVCT SolidC 3in1 RJ45 35mmCtr 250A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 250A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 300A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 400A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 500A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 600A:1/3V LVCT SolidC 3in1 RJ45 45mmCtr 630A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 60A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 100A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 120A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 125A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 150A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 160A:1/3V LVCT SolidC 3in1 RJ45 29mmCtr 200A:1/3V LVCT SolidC 3in1 RJ45 70mmCtr 800A:1/3V LVCT SolidC 3in1 RJ45 70mmCtr 1000A:1/3V LVCT SolidC 3in1 RJ45 70mmCtr 1250A:1/3V Panel Instruments 31 DIN rail analog ammeters, voltmeters 31 0-30 A no 8 X/5 8 0-5 A 0-50 A 50/5 0-75 A 75/5 0-100 A 100/5 0-150 A 150/5 0-200 A 200/5 0-250 A 250/5 0-300 A 300/5 0-400 A 400/5 Version: 1.0 - 27/01/2020 PLSED309005EN_12 239 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS PowerLogic Commercial Reference Numbers Commercial ref. no. 16040 16041 16042 16043 16044 16045 16060 16061 15202 15209 15201 15208 16003 16004 16009 16010 16011 16012 16013 16014 16015 16016 16019 16003 16006 16007 16008 16005 16074 16079 16080 16081 16082 16083 16084 16085 16086 16087 16088 16089 16090 16091 16092 16073 16076 16077 16078 16075 16017 16018 15126 15125 15440 15607 15608 15609 Description 0-500 A 500/5 0-600 A 600/5 0-800 A 800/5 0-1000 A 1000/5 0-1500 A 1500/5 0-2000 A 2000/5 0-300 V 8 0-500 V 8 DIN rail digital ammeters, voltmeter, freq meter Direct reading iAMP 0-10 A No 4 Multi-rating iAMP 0-5000 A As per rating 4 iVLT 0-600 V 4 iFRE 20-100 Hz 4 72x72 analog ammeter, voltmeter AMP for motor feeder AMP for standard feeder X/5 AMP for standard feeder 0-50 A 50/5 AMP for standard feeder 0-100 A 100/5 AMP for standard feeder 0-200 A 200/5 AMP for standard feeder 0-400 A 400/5 AMP for standard feeder 0-600 A 600/5 AMP for standard feeder 0-1000 A 1000/5 AMP for standard feeder 0-1250 A 1250/5 AMP for standard feeder 0-1500 A 1500/5 AMP for standard feeder 0-2000 A 2000/5 AMP for motor feeder X/5 AMP for motor feeder 0-30-90 A 30/5 AMP for motor feeder 0-75-225 A 75/5 AMP for motor feeder 0-200-600 A 200/5 VLT 0-500 V 96x96 analog ammeter, voltmeter AMP for standard feeder X/5 AMP for standard feeder 0-50 A 50/5 AMP for standard feeder 0-100 A 100/5 AMP for standard feeder 0-200 A 200/5 AMP for standard feeder 0-400 A 400/5 AMP for standard feeder 0-600 A 600/5 AMP for standard feeder 0-1000 A 1000/5 AMP for standard feeder 0-1250 A 1250/5 AMP for standard feeder 0-1500 A 1500/5 AMP for standard feeder 0-2000 A 2000/5 AMP for standard feeder 0-2500 A 2500/5 AMP for standard feeder 0-3000 A 3000/5 AMP for standard feeder 0-4000 A 4000/5 AMP for standard feeder 0-5000 A 5000/5 AMP for standard feeder 0-6000 A 6000/5 AMP for motor feeder X/5 AMP for motor feeder 0-30-90 A 30/5 AMP for motor feeder 0-75-225 A 75/5 AMP for motor feeder 0-200-600 A 200/5 VLT 0-500 V 48x48 CMA, CMV selector switches CMA 20 4 CMV 500 7 DIN rail iCMA, iCMV selector switches iCMA 10 415 4 iCMV 10 415 4 iCH hour counter iCH "DIN" 230 V AC � 10 %/50 Hz 4mm CH "48 x 48" 24 V AC � 10 %/50 Hz CH "48 x 48" 230 V AC � 10 %/50 Hz CH "48 x 48" 12 to 36 V DC Commercial Page ref. no. 15443 A9MEM2000T A9MEM2000 A9MEM2010 A9MEM2100 A9MEM2050 33 A9MEM2055 A9MEM2105 A9MEM2110 34 A9MEM2135 A9MEM2150 A9MEM2155 A9MEM3100 A9MEM3110 A9MEM3115 A9MEM3135 A9MEM3150 35 A9MEM3155 A9MEM3165 A9MEM3175 A9MEM3200 A9MEM3210 A9MEM3215 A9MEM3235 A9MEM3250 A9MEM3255 A9MEM3265 A9MEM3275 36 A9MEM3300 A9MEM3310 A9MEM3335 37 A9MEM3350 38 A9MEM3355 Description Page iCI impulse counter 39 iCI 4mm impulse counter DIN Basic Energy Metering 42 iEM2000 43 iEM2000T basic energy meter, no display iEM2000 basic energy meter iEM2010 energy meter, kWh pulse output iEM2100 basic energy meter iEM2050 modular single phase power meter 230 V - 45 A with Modbus iEM2055 modular single phase power meter 230 V - 45 A with Modbus, MID iEM2105 energy meter, kWh pulse output with partial meter iEM2110 energy meter, kWh and kvarh pulse outputs with two tariffs, four quadrant energy measurement, MID certified iEM2135 energy meter, M-Bus communication, four quadrant energy measurement, two tariffs, MID certified iEM2150 energy meter, Modbus communication, four quadrant energy measurement iEM2155 energy meter, Modbus communication, four quadrant energy measurement, two tariffs, MID certified iEM3000 50 iEM3100 basic energy meter iEM3110 energy meter with pulse output iEM3115 multi-tariff energy meter iEM3135 advanced multi-tariff energy meter & electrical parameter plus M-Bus comm port iEM3150 energy meter & electrical parameter plus Modbus RS-485 comm port iEM3155 advanced multi-tariff energy meter & electrical parameter plus Modbus RS-485 comm port iEM3165 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm port iEM3175 advanced multi-tariff energy meter & electrical parameter plus LON TP/FT-10 comm port iEM3200 basic energy meter iEM3210 energy meter with pulse output iEM3215 multi-tariff energy meter iEM3235 advanced multi-tariff energy meter & electrical parameter plus M-Bus comm port iEM3250 energy meter & electrical parameter plus Modbus RS-485 comm port iEM3255 advanced multi-tariff energy meter & electrical parameter plus Modbus RS485 comm port iEM3265 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm port iEM3275 advanced multi-tariff energy meter & electrical parameter plus LON TP/FT-10 comm port iEM3300 basic energy meter iEM3310 energy meter with pulse output iEM3335 advanced multi-tariff energy meter & electrical parameter plus M-Bus comm port iEM3350 energy meter & electrical parameter plus Modbus RS-485 comm port iEM3355 advanced multi-tariff energy meter & electrical parameter plus Modbus RS485 comm port 240 Version: 1.0 - 27/01/2020 PLSED309005EN_12 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS PowerLogic Commercial Reference Numbers Commercial ref. no. Description Commercial Page ref. no. Description Page A9MEM3365 iEM3365 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm port A9MEM3375 iEM3375 advanced multi-tariff energy meter & electrical parameter plus LON TP/FT-10 comm port A9MEM3455 iEM3455 advanced multi-tariff energy meter & electrical parameter plus Modbus RS-485 comm port A9MEM3465 iEM3465 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm port A9MEM3555 iEM3555 advanced multi-tariff energy meter & electrical parameter plus Modbus RS-485 comm port A9MEM3565 iEM3565 advanced multi-tariff energy meter & electrical parameter plus BACnet MS/TP comm port LVCTs 49 LVCT00050S CT, split-core, Size 0, 50 A to 0.333 V LVCT00101S CT, split-core, Size 1, 100 A to 0.333 V LVCT00201S CT, split-core, Size 1, 200 A to 0.333 V LVCT00102S CT, split-core, Size 2, 100 A to 0.333 V LVCT00202S CT, split-core, Size 2, 200 A to 0.333 V LVCT00302S CT, split-core, Size 2, 300 A to 0.333 V LVCT00403S CT, split-core, Size 3, 400 A to 0.333 V LVCT00603S CT, split-core, Size 3, 600 A to 0.333 V LVCT00803S CT, split-core, Size 3, 800 A to 0.333 V LVCT00804S CT, split-core, Size 4, 800 A to 0.333 V LVCT01004S CT, split-core, Size 4, 1000 A to 0.333 V LVCT01204S CT, split-core, Size 4, 1200 A to 0.333 V LVCT01604S CT, split-core, Size 4, 1600 A to 0.333 V LVCT02004S CT, split-core, Size 4, 2000 A to 0.333 V LVCT02404S CT, split-core, Size 4, 2400 A to 0.333 V Basic Multi-Function Metering 57 ION6200 58 M6200 PowerLogic ION6200 meter PM3000 65 METSEPM3200 PM3200 basic power meter METSEPM3210 PM3210 power meter with pulse output METSEPM3250 PM3250 power meter with RS485 port METSEPM3255 PM3255 power meter plus 2 digital inputs, 2 digital outputs with RS-485 port METSEPM5320 PM5350/PM5350IB/PM5350PB/PM5350P 71 PM5320 Power & Energy meter with THD, alarming METSEPM5340 METSEPM5350 METSEPM5350PB/IB PM5320 Power & Energy meter with THD, alarming PM5350 Power & Energy meter with THD, alarming PM5350PB/IB METSEPM5350P METSEPM5100 METSEPM5110 METSEPM5111 METSEPM5310 METSEPM5310R METSEPM5320 PM5350 Power & Energy meter with THD, alarming, multi-tariff and individual harmonics PM5000 94 Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 15th harmonic, no communication, 1DO Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 15th harmonic, RS-485 Modbus, 1DO Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 15th harmonic, RS-485 Modbus, 1DO, MID cert Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RS-485 Modbus, 2DI/2DO Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RJ45 LVCT, RS-485 Modbus, 2DI/2DO Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, Ethernet, 2DI/2DO METSEPM5320R METSEPM5330 METSEPM5331 METSEPM5340 METSEPM5341 METSEPM5560 METSEPM5561 METSEPM5562 METSEPM5562MC METSEPM5563* METSEPM5563RD* Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RJ45 LVCT, Ethernet, 2DI/2DO Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RS-485 Modbus, 2DI/2DO, 2Relay Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, RS-485 Modbus, 2DI/2DO, 2Relay, MID cert Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, Ethernet, 2DI/2DO, 2Relay Power Meter range 72 mm depth, control power to 415 V AC, Cl 0.5S, 31st harmonic, 256 kB, Ethernet, 2DI/2DO, 2Relay, MID cert Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, Modbus and Ethernet, 4DI/2DO Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, Modbus and Ethernet, MID cert Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, RMICAN approved, HW lockable, 4DI/2DO Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, RMICAN approved, factory sealed, 4DI/2DO Power Meter range 77 mm depth, control power to 480 V AC, Cl 0.2S, 63rd harmonic, 1.1 MB, DIN mount, no display, 4DI/2DO PM5500 power meter, ETH-serial + 4DI-2DO out, remote display METSEPM5RD* Remote display for PM5563 power meter *METSEPM5563RD includes both METSEPM5563 and METSEPM5RD METSEPM51HK Hardware kit for PM51XX (voltage, current, comms & IO connectors + moulding clips) METSEPM53HK Hardware kit for PM53XX (voltage, current, comms & IO connectors + moulding clips) METSEPM51_3RSK Revenue sealing kit for PM51XX & PM53XX (sealing covers for voltage & current connectors) METSEPM55HK Hardware kit for PM55XX (voltage, current, comms & IO connectors & moulding clips) METSEPM55RSK Revenue sealing kit for PM55XX (sealing covers for voltage & current connectors) Cables 103 METSEPM5CAB3 Remote Display cable DCEPCURJX5GYM Category 5e, Patch Cord, UTP, 0.5 M, Grey DCEPCURJ01GYM DCEPCURJ02GYM DCEPCURJ03GYM DCEPCURJ05GYM DCEPCURJ10GYM Category 5e, Patch Cord, UTP, 1 M, Grey Category 5e, Patch Cord, UTP, 2 M, Grey Category 5e, Patch Cord, UTP, 3 M, Grey Category 5e, Patch Cord, UTP, 5 M, Grey Category 5e, Patch Cord, UTP, 10 M, Grey Advanced Metering 105 PM8000 106 METSEPM8240 DIN96 panel mount meter METSEPM8243 DIN rail mount meter METSEPM8244 DIN rail mount meter with remote display METSEPM89RD96 Remote display, 3 metre cable, mounting hardware for 30mm hole (nut & centering pin), mounting hardware for DIN96 cutout (92x92mm) adapter plate METSEPM8000SK METSEPMAK Terminal covers for utility sealing Adapters for mounting meter and remote display back to back & ANSI 4�, 0.3 metre (1 ft.) Ethernet cable METSECAB1 Display Cable, 1 metre METSECAB3 Display Cable, 3 metres METSECAB10 Display Cable, 10 metres METSEPM8HWK PM8000 hardware kit Version: 1.0 - 27/01/2020 PLSED309005EN_12 241 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS PowerLogic Commercial Reference Numbers Commercial ref. no. Description Page METSEPM8RDHWK PM8000 remote display hardware kit METSEPM89M2600 Digital I/O module (6 digital inputs & 2 relay outputs) METSEPM89M0024 Analog I/O module (4 analog inputs & 2 analog outputs) ION9000 116 METSEION92030 ION9200 meter, DIN mount, no display, HW kit METSEION92040 METSEION95030 ION9200 meter, DIN mount, 192 mm display, B2B adapter, HW kit ION9000T HSTC meter, DIN mount, no display, hardware kit METSEION95040 METSEPM89RD96 ION9000T HSTC meter, DIN mount, 192 mm display, B2B adapter, hardware kit Remote display, color LCD, 96 x 96 mm METSERD192 METSEPM89M2600 Remote display, color touchscreen, 192 x 192 mm I/O module, 2 relay outputs, 6 digital inputs METSEPM89M0024 I/O module, 2 analog outputs, 4 analog inputs METSE9HWK ION9000 meter hardware kit � plugs, terminal guards, spare grounding screw, DIN clips METSERD192HWK METSE9B2BMA RD192 remote display hardware kit ION9000 B2B adapter METSE92040DEMOK ION9000 Demo Kit METSE9USBK ION9000 USB cover hardware kit METSE9CTHWK METSEPMBATK ION9000 Current Input hardware kit � terminal screws, CT covers Battery replacement kit � ION7400/ION9000/ PM8000 METSE7X4MAK ION7x50 Mounting Adapter Kit Advanced Utility Metering 127 METSEION7400 ION7400 128 ION7400 Panel mount meter (integrated display with optical port and 2 energy pulse LEDs) METSEION7403 DIN rail mount - utility meter base METSEPM89RD96 Remote display, 3 m cable, mounting hardware for 30 mm hole and DIN96 cutout (92 x 92 mm) adapter plate METSEPM89M2600 Digital I/O module (6 digital inputs (wetted) & 2 relay outputs) METSEPM89M0024 Analog I/O module (4 analog inputs & 2 analog outputs) METSEPM8000SK Revenue sealing kit METSECAB10 Display Cable, 10 m ION8650 138 M8650A ION8650A meter M8650B ION8650B meter M8650C ION8650C meter A-BASE-ADAPTER-9 Form 9S to Form 9A adapter A-BASEADAPTER-35 Form 35S to Form 35A adapter CBL-8X00BRKOUT Break out cable 1.5 m CBL-8X00IOE5FT Cable para I/O expander 1.5 m CBL-8X00IOE15FT I/O extension cable 4.6 m CBL-8XX0-BOPIOBOX Cat.3 25PR UTP cable 205 m reel ION8800 148 M8800A ION8800A meter M8800B ION8800B meter M8800C ION8800C meter OPTICAL-PROBE ION8800 optical probe with DB9 connector OPTICAL-PROBEUSB ION8800 optical probe with USB connector Multi-Circuit Metering 157 BCPMA084S BCPMA184S BCPM (Branch Circuit Power Meter) 158 84-circuit solid-core power & energy meter, 100A CTs (4 strips), 19.05 mm spacing 84-circuit solid-core power & energy meter, 100A CTs (4 strips), 25.4 mm spacing Commercial ref. no. BCPMA042S BCPMA142S BCPMA224S BCPMA236S BCPMA242S BCPMA248S BCPMA272S BCPMA284S BCPMB084S BCPMB184S BCPMB042S BCPMB142S BCPMB224S BCPMB236S BCPMB242S BCPMB248S BCPMB272S BCPMB284S BCPMC084S BCPMC184S BCPMC042S BCPMC142S BCPMC224S BCPMC236S BCPMC242S BCPMC248S BCPMC272S BCPMC284S BCPME042S BCPME084S BCPME142S BCPME184S Description Page 42-circuit solid-core power & energy meter, 100A CTs (2 strips), 19.05 mm spacing 42-circuit solid-core power & energy meter, 100A CTs (2 strips), 25.4 mm spacing 24-circuit solid-core power & energy meter, 100A CTs (2 strips), 18 mm spacing 36-circuit solid-core power & energy meter, 100A CTs (2 strips), 18 mm spacing 42-circuit solid-iEM2000core power & energy meter, 100 A CTs (2 strips), 18 mm spacing 48-circuit solid-core power & energy meter, 100 A CTs (4 strips), 18 mm spacing 72-circuit solid-core power & energy meter, 100 A CTs (4 strips), 18 mm spacing 84-circuit solid-core power & energy meter, 100 A CTs (4 strips), 18 mm spacing 84-circuit solid-core branch current, mains power meter, 100 A CTs (4 strips), 19.05 mm spacing 84-circuit solid-core branch current, mains power meter, 100 A CTs (4 strips), 25.4 mm spacing 42-circuit solid-core branch current, mains power meter, 100 A CTs (2 strips), 19.05 mm spacing 42-circuit solid-core branch current, mains power meter, 100 A CTs (2 strips), 25.4 mm spacing 24-circuit solid-core branch current, mains power meter, 100 A CTs (2 strips), 18 mm spacing 36-circuit solid-core branch current, mains power meter, 100 A CTs (2 strips), 18 mm spacing 42-circuit solid-core branch current, mains power meter, 100 A CTs (2 strips), 18 mm spacing 48-circuit solid-core branch current, mains power meter, 100 A CTs (4 strips), 18 mm spacing 72-circuit solid-core branch current, mains power meter, 100 A CTs (4 strips), 18 mm spacing 84-circuit solid-core branch current, mains power meter, 100 A CTs (4 strips), 18 mm spacing 84-circuit solid-core branch current meter, 100 A CTs (4 strips), 19.05 mm spacing 84-circuit solid-core branch current meter, 100 A CTs (4 strips), 25.4 mm spacing 42-circuit solid-core branch current meter, 100 A CTs (2 strips), 19.05 mm spacing 42-circuit solid-core branch current meter, 100 A CTs (2 strips), 25.4 mm spacing 24-circuit solid-core branch current meter, 100 A CTs (2 strips), 18 mm spacing 36-circuit solid-core branch current meter, 100 A CTs (2 strips), 18 mm spacing 42-circuit solid-core branch current meter, 100 A CTs (2 strips), 18 mm spacing 48-circuit solid-core branch current meter, 100 A CTs (4 strips), 18 mm spacing 72-circuit solid-core branch current meter, 100 A CTs (4 strips), 18 mm spacing 84-circuit solid-core branch current meter, 100 A CTs (4 strips), 18 mm spacing 42-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (2 strips), 19.05 mm spacing 84-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (4 strips), 19.05 mm spacing 42-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (2 strips), 25.4 mm spacing 84-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (4 strips), 25.4 mm spacing 242 Version: 1.0 - 27/01/2020 PLSED309005EN_12 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS PowerLogic Commercial Reference Numbers Commercial ref. no. BCPME224S BCPME236S BCPME242S BCPME248S BCPME272S BCPME284S BCPMSCA1S BCPMSCA2S BCPMSCA30S BCPMSCA42S BCPMSCA60S BCPMSCA84S BCPMSCB1S BCPMSCB2S BCPMSCB30S BCPMSCB42S BCPMSCB60S BCPMSCBY63S BCPMSCB84S BCPMSCC1S BCPMSCC2S BCPMSCC30S BCPMSCC42S BCPMSCC60S BCPMSCCY63S BCPMSCC84S BCPMSCE1S BCPMSCE2S BCPMSCE30S BCPMSCE42S BCPMSCE60S BCPMSCE84S Description Page 24-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (2 strips), 18 mm spacing 36-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (2 strips), 18 mm spacing 42-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (2 strips), 18 mm spacing 48-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (4 strips), 18 mm spacing 72-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (4 strips), 18 mm spacing 84-circuit solid-core power & energy meter w/Ethernet, 100 A CTs (4 strips), 18 mm spacing 42-circuit split-core power and energy meter, CTs and cables sold separately 84-circuit split-core power and energy meter, CTs and cables sold separately 30-circuit split-core power and energy meter, (30) 50 A CTs & (2) 1.21 m cables 42-circuit split-core power and energy meter, (42) 50 A CTs & (2) 1.21 m cables 60-circuit split-core power and energy meter, (60) 50 A CTs & (4) 1.21 m cables 84-circuit split-core power and energy meter, with (84) 50 A CTs & (4) 1.21 m cables 42-circuit split-core branch current, mains power meter, CTs and cables sold separately 84-circuit split-core branch current, mains power meter, CTs and cables sold separately 30-circuit split-core branch current, mains power meter, (30) 50 A CTs & (2) 1.21 m cables 42-circuit split-core branch current, mains power meter, (42) 50 A CTs & (2) 1.21 m cables 60-circuit split-core branch current, mains power meter, (60) 50 A CTs & (4) 1.21 m cables 42-circuit split-core branch current, mains, all boards on backplate, CTs and cables sold separately 84-circuit split-core branch current, mains power meter, (84) 50 A CTs & (4) 1.21 m cables 42-circuit split-core current meter, CTs and cables sold separately 84-circuit split-core current meter, CTs and cables sold separately 30-circuit split-core current meter, (30) 50 A CTs & (2) 1.21 m cables 42 circuit split-core current meter, (42) 50 A CTs & (2) 1.21 m cables 60-circuit split-core current meter, (60) 50 A CTs & (4) 1.21 m cables 42-circuit split-core current meter, all boards on backplate, CTs and cables sold separately 84-circuit split-core current meter, (84) 50 A CTs & (4) 1.21 m cables 42-circuit split-core power and energy meter w/Ethernet, CTs and cables sold separately 84-circuit split-core power and energy meter w/Ethernet, CTs and cables sold separately 30-circuit split-core power and energy meter w/Ethernet, (30) 50A CTs & (2) 1.21 m cables 42-circuit split-core power and energy meter w/Ethernet, (42) 50 A CTs & (2) 1.21 m cables 60-circuit split-core power and energy meter w/Ethernet, (60) 50 A CTs & (4) 1.21 m cables 84-circuit split-core power and energy meter w/Ethernet, (84) 50 A CTs & (4) 1.21 m cables Commercial ref. no. Description Page BCPMSCADPBS BCPMSCCT0 BCPMSCCT0R20 BCPMSCCT1 BCPMSCCT1R20 BCPMSCCT3 BCPMSCCT3R20 BCPMCOVERS BCPMREPAIR H6803R-0100 E8951 BCPM adapter boards, quantity 2, for split core BCPM BCPM 50 A split core CTs, Quantity 6, 1.8 m lead lengths BCPM 50 A split core CTs, quantity 6, 6 m lead lengths BCPM 100 A split core CTs, Quantity 6, 1.8 m lead lengths BCPM 100 A split core CTs, Quantity 6, 6 m lead lengths BCPM 200 A split core CTs, Quantity 1, 1.8 m lead lengths BCPM 200 A split core CTs, Quantity 1, 6 m lead lengths BCPM circuit board cover CT repair kit for solid core BCPM (includes one CT) H6803R-0100 Additional 100A split core CT for use with solid core repair kit Modbus to BACnet protocol converter CBL008 CBL016 Flat Ribbon cable for BCPM, length = 0.45 m Flat Ribbon cable for BCPM, length = 1.2 m CBL017 Flat Ribbon cable for BCPM, length = 1.5 m CBL018 CBL019 Flat Ribbon cable for BCPM, length = 1.8 m Flat Ribbon cable for BCPM, length = 2.4 m CBL020 Flat Ribbon cable for BCPM, length = 3.0 m CBL021 Flat Ribbon cable for BCPM, length = 6.1 m CBL022 Round Ribbon cable for BCPM, length = 1.2 m CBL023 Round Ribbon cable for BCPM, length = 3 m CBL024 Round Ribbon cable for BCPM, length = 6.1 m CBL031 Round Ribbon cable for BCPM, length = 0.5 m CBL033 Round Ribbon cable for BCPM, length = 0.8 m LVCT00050S 50 A 10 mm x 11 mm LVCT00101S 100 A 16 mm x 20 mm LVCT00102S 100 A 30 mm x 31 mm LVCT00202S 200 A 30 mm x 31 mm LVCT00302S 300 A 30 mm x 31 mm LVCT00403S 400 A 62 mm x 73 mm LVCT00603S 600 A 62 mm x 73 mm LVCT00803S 800 A 62 mm x 73 mm LVCT00804S 800 A 62 mm x 139 mm LVCT01004S 1000 A 62 mm x 139 mm LVCT01204S 1200 A 62 mm x 139 mm LVCT01604S 1600 A 62 mm x 139 mm LVCT02004S 2000 A 62 mm x 139 mm LVCT02404S 2400 A 62 mm x 139 mm LVCT20050S 50 A 10 mm LVCT20100S 100 A 10 mm LVCT20202S 200 A 25 mm EM4000 172 METSEEM403316 24 x 333 mV inputs, 120V control power 60 Hz METSEEM403336 24 x 333 mV inputs, 277V control power 60 Hz METSEEM408016 24 x 80 mA inputs, 120V control power 60 Hz METSEEM408036 24 x 80 mA inputs, 277V control power 60 Hz METSECONV580 EM4000 5 A : 80 mA converter METSEPTMOD480 480 V PT Module for EM4X00 meter METSEPTMOD347600 347 V/600 V PT Module for EM4X00 meter METSECTTERM EM4000 CT termination module METSECTSHORT EM4000 CT shorting module METSECT80200 METSECT80400 EM4000 solid-core CT 200 A / 80 mA secondary EM4000 solid-core CT 400 A / 80 mA secondary METSECT80600 EM4000 solid-core CT 600 A / 80 mA secondary Version: 1.0 - 27/01/2020 PLSED309005EN_12 243 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS PowerLogic Commercial Reference Numbers Commercial ref. no. METSEEM480525 METSEEM480516 METSEEM483325 METSEEM483316 METSEEM488016 Description Page EM4800 181 24 x 5 A inputs, 230/240 V control power, 50 Hz 24 x 5 A inputs, 120 V control power, 60 Hz 24 x 333 mV inputs, 230/240 V control power, 50 Hz 24 x 333 mV inputs, 120 V control power, 60 Hz 24 x 80 mA inputs, 120 V control power, 60 Hz METSEEM488026 24 x 80 mA inputs, 230/240 V control power, 50 Hz METSECONV580 EM4000 5 A : 80 mA converter METSEPTMOD480 480 V PT Module for EM4X00 meter METSEPTMOD347600 347 V/600 V PT Module for EM4X00 meter METSECTTERM METSECTSHORT METSECT80200 METSECT80400 METSECT80600 METSEEM4904A METSEEM4908A METSEEM4914A METSEEM4928A METSEEM4904E METSEEM4908E METSEEM4914E METSEEM4928E METSEEM3502 METSEEM3550 METSEEM3555 METSEEM3560 METSEEM3502A METSEEM3550A METSEEM3560A METSEEM3561 METSEEM3561A METSEEM4235 METSEEM4236 EGX150 EBX200 EBX210 EBX510 EBXA-GPRS-SIM EBXA-ANT-5M EBXA-USB-Zigbee EM4000 CT termination module EM4000 CT shorting module EM4000 solid-core CT 200 A / 80 mA secondary EM4000 solid-core CT 400 A / 80 mA secondary EM4000 solid-core CT 600 A / 80 mA secondary EM4900 186 EM4900 (4) 3-phase meters - Modbus RTU only EM4900 (8) 3-phase meters - Modbus RTU only EM4900 (14) 3-phase meters - Modbus RTU only EM4900 (28) 3-phase meters - Modbus RTU only EM4900 (4) 3-phase meters - Ethernet and Serial (Modbus, BACnet & SNMP) EM4900 (8) 3-phase meters - Ethernet and Serial (Modbus, BACnet & SNMP) EM4900 (14) 3-phase meters - Ethernet and Serial (Modbus, BACnet & SNMP) EM4900 (28) 3-phase meters - Ethernet and Serial (Modbus, BACnet & SNMP) Retrofit Products 195 EM3500 196 EM3502 Pulse out only EM3550 Modbus - 2 quadrant EM3555 Modbus - 4 quadrant with logging EM3560 BACnet with logging EM3502A Pulse Rope CT model EM3550A Modbus Rope CT Model EM3560A BACnet w/ logging Rope CT Model EM3561 BACnet without logging EM3561A BACnet without loggingRope CT Model EM4200 202 Enercept, Class 0.2S meter, Modbus/ BACnet communication, Uni-Directional/ Bi-Directional, RS-485, IEC wire code, single circuit, Modbus/BACnet Enercept, Class 0.2S meter, Modbus/BACnet communication, Uni-Directional/BiDirectional, RS-485, ANSI wire code, single circuit, Modbus/BACnet Communications & Gateways 208 Link150 Ethernet gateway 211 Link150 Ethernet gateway Com'X 200/210/510 215 Com'X 200 data logger 24 V DC or 230 V AC power supplied Com'X 210 data logger 24 V DC power supplied UL rated Com'X 510 energy server 24 V DC power supplied UL rated Com'X GPRS interface SIM card Com'X External GPRS antenna Com'X Zigbee USB interface Commercial ref. no. M7550 M7550A0N9B9A0A0A M7550A0N9B9E0A0A M7550A0N9B9E0E0A 50310 50281 50282 50283 50278 50494 50498 50499 50285 50170 50171 50172 50183 50169 50248 50159 IMD-IM20-1700 IMD-IM400-1700 IMD-IM400-1700C IMD-IM400VA2 50168 50540 50541 50542 IMD-IM10 IMD-IM10-H IMD-IM20 IMD-IM20-H IMD-IM9 IMD-IM9-OL IMD-IM400 IMD-IM400C 50490 50491 50492 50322 50323 50324 50606 50607 50608 50615 50616 50617 50723 50724 50725 50506 50507 50508 50535 Description ION7550 RTU ION7550 RTU 7550-I/5M/512S-RTU-P240-SCOM PML 7550 PO SE-7550-I/5M/512S-RTU-P240-ETH PML 7550 SE-7550-I/5M/512S-RTU-P240-ETH-20MAI PML Insulation Monitoring Vigilohm Insulation Monitoring Case XGR(230 V CA) +XRM+3Clamp-on CTs XGR 115-127 V CA XGR 220-240 V CA XGR 380-415 V CA XRM XP15 Clamp-on toroid for XRM XP50 Clamp-on toroid for XRM XP100 Clamp-on toroid for XRM Empty case Surge arrestor CARDEW 250 V CA Surge arrestor CARDEW 440 V CA Surge arrestor CARDEW 660 V CA Surge arrestor CARDEW 1000 V CA Base CARDEW PHT1000 ZX resistance grounded Voltage Adaptor for IM20 Voltage Adaptor for IM400 Voltage Adaptor for IM400C Voltage adaptor for PV application_Coated HOSPITAL REMOTE PANEL XM300C 115-127 V CA XM300C 200-240 V CA XM300C 380-415 V CA IM10 IM10 H IM20 IM20 H IM9 IM9Off-Line IM400 IM400C XML308 115-127 V CA XML308 220-240 V CA XML308 380-415 V CA XML316 115-127 XML316 220-240 V CA XML316 380-415 V CA XL308 115/127 V CA XL308 220-240 V CA XL308 380-415 V CA XL316 115/127 V CA XL316 220-240 V CA XL316 380-415 V CA XD308C 115-127 V CA XD308C 220-240 V CA XD308C 380-415 V CA XD301 115-127 V CA XD301 220-240 V CA XD301 380-415 V CA XD312 115-127 V CA Page 225 234 235 244 Version: 1.0 - 27/01/2020 PLSED309005EN_12 BASIC ENERGY METERING FUNCTIONS AND CHARACTERISTICS PowerLogic Commercial Reference Numbers Commercial ref. no. Description Page 50536 XD312 220-240 V CA 50537 XD312 380-415 V CA 50536-H XD312 220-240 V CA FOR HOSPITAL 50515 XLI300 115/127 V CA 50516 XLI300 220/240 V CA 50517 XLI300 380/415 V CA 50545 XTU300115/127 V CA 50546 XTU300 220/240 V CA 50547 XTU300 380/415 V CA 50437 Toroid TA30 50438 Toroid PA50 50439 Toroid IA80 50440 Toroid MA120 50441 Toroid SA200 50442 Toroid GA300 50485 Toroid Ouvert POA 50486 Toroid Ouvert GOA 50420 Toroid ouvert TOA80 50421 Toroid ouvert TOA120 Please see your Schneider Electric Representative for complete ordering information. Version: 1.0 - 27/01/2020 PLSED309005EN_12 245 www.se.com Schneider Electric Industries SAS 35, Rue Joseph Monier CS 30323 92506 Rueil Malmaison Cedex RCS Nanterre 954 503 439 Capital social 928 298 512 www.se.com September 2020 PowerLogicTM Catalog PLSED309005EN � 2020 - Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. As standards, specifications and designs develop from time to time, please ask for confirmation of the information given in this document. Over 75 % of Schneider Electric products have been awarded the Green Premium ecolabel.