Form 35™ Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC — Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4)
Form 35TM Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC -- Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4) Applications · Serve as pulling fittings. · Make bends in conduit system. · Provide openings for splicing. · Connect and change direction of conduit runs. · Allow connections for branch runs. · Permit access to conductors for maintenance. Features · Smooth, rounded integral bushings in hubs protect conductor insulation. · Accurately tapped, tapered threads for tight, rigid joints and excellent ground continuity. · Form 35TM malleable iron UniletsTM: high tensile strength and ductility. High corrosion-resistance, high impact and shock resistance. · Exclusive built-in easy-pulling rollers in type C (1-1/4" thru 4") and type LB (1-1/4" thru 4"): eliminate damage when cable is pulled through hubs. · Sizes with flat-back design ideal where fitting is mounted flat against surface. · 1/2" to 3" blank covers are domed for extra wiring space. Standard Materials · Bodies: malleable iron · Blank covers: malleable iron, steel or aluminum · Cover screws: stainless steel · Gaskets: neoprene or composition fiber Standard Finishes · Malleable iron bodies and covers: triple-coat -- (1) zinc electroplate, (2) chromate, and (3) epoxy powder coat · Steel covers: zinc electroplate NEC/CEC Certifications and Compliances · UL Standards: 514A, 514B · UL Listed: E2527 · CSA Standard: C22.2 No. 18.3 · CSA Certified: 065183 · NEMA Standard: FB-1 Related Products · For explosionproof conduit outlet bodies and boxes, see Enclosures and Junction Boxes in Protection and Control of Electrical Apparatus and Circuits Catalog. 2" Type LB with rollers shown COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES Visit our website at www.emerson.com or contact us at (800) 621-1506. 9 © January 2021 Form 35TM Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC -- Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4) Threaded Type Conduit Bodies Hub Size Max. Wire Max. Wire Max. Wire (Inches) Fill C Fill E Fill LB 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 Hub Size (Inches) (3) # 6 (3) # 4 (3) # 2 (3) # 1/0 (3) # 4/0 (3) 300 (3) 300 (3) 350 (3) 350 -- Max. Wire Fill C-50M C-75M C-100M C-125M C-150M C-200M C-250M C-300M C-350M C-400M -- LRL (3) # 6 (3) # 4 (3) #2 (3) # 1/0 -- -- -- -- -- -- Max. Wire Fill E-50M E-75M E-100M E-125M E-150M -- -- -- -- -- -- T (3) # 6 (3) # 4 (3) # 2 (3) # 1/0 (3) # 4/0 (3) 300 (3) 400 (3) 500 (3) 500 (3) 600 Max. Wire Fill LB-50M LB-75M LB-100M LB-125M LB-150M LB-200M LB-250M LB-300M LB-350M LB-400M LB-500M TA COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 (3) # 6 (3) # 4 (3) # 2 (3) # 1/0 (3) # 4/0 -- -- -- -- LRL-50M LRL-75M LRL-100M LRL-125M LRL-150M LRL-200M -- -- -- -- (3) # 6 (3) # 6 (3) # 6 (3) # 4 (3) # 1/0 (3) 300 (3) 300 (3) 350 (3) 350 T-50M T-75M T-100M T-125M T-150M T-200M T-250M T-300M T-350M T-400M (3) # 6 (3) # 4 -- -- -- -- -- -- -- TA-50M TA-75M TA-100M -- -- -- -- -- -- -- All 1/2" Max Wire Fill Calculations per the NEC - Annex C - Table C8. Catalog numbers having roller feature, all others do not. LRL Unilets have double opening and are furnished with one steel cover, assembled. 10 Visit our website at www.emerson.com or contact us at (800) 621-1506. © January 2021 Form 35TM Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC -- Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4) Threaded Type Conduit Bodies Hub Size (Inches) Max. Wire Fill LL Max. Wire Fill LR 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 Hub Size (Inches) (3) # 6 (3) # 4 (3) # 2 (3) # 1/0 (3) # 4/0 (3) 300 (3) 350 (3) 350 (3) 350 -- -- Max. Wire Fill LL-50M LL-75M LL-100M LL-125M LL-150M LL-200M LL-250M LL-300M LL-350M LL-400M -- -- TB (3) # 6 (3) # 4 (3) # 2 (3) # 1/0 (3) # 4/0 (3) 300 (3) 350 (3) 350 (3) 350 -- -- Max. Wire Fill LR-50M LR-75M LR-100M LR-125M LR-150M LR-200M LR-250M LR-300M LR-350M LR-400M -- -- X COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 (3) # 6 (3) # 6 (3) # 6 (3) # 4 (3) # 1/0 -- -- -- -- TB-50M TB-75M TB-100M TB-125M TB-150M TB-200M -- -- -- -- (3) # 6 (3) # 4 (3) # 4 (3) # 1/0 (3) # 2/0 -- -- -- -- Back Style for Form 35TM Unilet Conduit Body Sizes (Inches) Unilet Body C, LB E LL, LR, T Flat Back 1/2 2 1/2 1-1/2 1/2 2 Round Back 2-1/2 and up 1-1/4 and up 2-1/2 and up Unilet Body TB X TA Flat Back 1/2 1-1/2 1/2 2 All sizes X-50M X-75M X-100M X-125M X-150M X-200M -- -- -- -- Round Back 1/2, 3/4, 1, 2 1-1/4 and up All 1/2" Max Wire Fill Calculations per the NEC - Annex C - Table C8. Visit our website at www.emerson.com or contact us at (800) 621-1506. 11 © January 2021 Form 35TM Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit. NEC/CEC -- Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4) Wiring Capacity: Combine Body and Cover Capacities for Total Usable Capacity per NEC 314.16(A) Hub Size (Inches) C Capacity dm3 (in3) E LB LL & LR LRL T TA TB X 1/2 0.07 (4.50) 0.07 (4.50) 0.07 (4.50) 0.07 (4.50) 0.08 (5.00) 0.10 (6.00) 0.07 (4.30) 0.07 (4.30) 0.10 (6.00) Stamped Cover 0.01 (0.50) Cast Cover 0.00 (0.00) 3/4 0.12 (7.50) 0.12 (7.50) 0.12 (7.50) 0.12 (7.50) 0.14 (8.80) 0.16 (9.50) 0.11 (7.00) 0.11 (7.00) 0.16 (9.50) 0.01 (0.80) 0.00 (0.30) 1 0.20 (12.50) 0.20 (12.50) 0.20 (12.50) 0.20 (12.50) 0.23 (14.30) 0.25 (15.00) 0.25 (15.00) 0.21 (13.00) 0.25 (15.00) 25.4 (1.00) 0.01 (0.50) 1-1/4 0.57 (35.00) 0.48 (29.30) 0.53 (32.30) 0.52 (32.00) 0.57 (34.80) 0.54 (33.00) -- 0.57 (35.00) 0.52 (31.50) 0.04 (2.50) 0.01 (0.80) 1-1/2 0.58 (35.30) 0.53 (32.50) 0.58 (35.30) 0.58 (35.30) 0.66 (40.00) 0.59 (36.00) -- 0.58 (35.30) 0.66 (40.00) 0.04 (2.50) 0.01 (0.80) 2 1.23 (75.00) -- 1.20 (73.00) 1.20 (73.00) 1.39 (85.00) 1.16 (71.00) -- 1.16 (71.00) 1.16 (71.00) 0.11 (6.50) 0.02 (1.00) 2-1/2 2.34 (143.00) -- 2.28 2.30 (139.00) (140.50) -- 2.39 (146.00) -- -- -- 0.29 (18.00) 0.49 (30.00) 3 2.95 (180.00) -- 2.90 2.87 (177.00) (175.00) -- 3.03 (185.00) -- -- -- 0.29 (18.00) 0.49 (30.00) 3-1/2 4.97 (303.00) -- 4.92 4.92 (300.00) (300.00) -- 5.15 (314.00) -- -- -- -- 0.82 (50.00) 4 5.57 (340.00) -- 5.41 5.41 (330.00) (330.00) -- 5.65 (345.00) -- -- -- -- 0.82 (50.00) 5 -- -- 12.39 (756.00) -- -- -- -- -- -- -- -- 6 -- -- 21.76 (1328.00) -- -- -- -- -- -- -- -- COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES 12 Visit our website at www.emerson.com or contact us at (800) 621-1506. © January 2021 Form 35TM Malleable Iron Conduit Outlet Bodies, Covers and Gaskets Covers Furnished with Stainless Steel Fastening Screws. NEC/CEC -- Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4) Covers and Gaskets Body Size (Inches) Blank Stamped Steel Blank Cast Malleable Neoprene Composition Fiber 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 Domed: 1/2" - 3" Flat: 1/2" - 2" Flat: 3-1/2" - 6" K50 K75 K100 K125-150 K125-150 K200 K250-300 K250-300 K350-400 K350-400 K500 K600 Domed: 2-1/2" - 4" K50-CM K75-CM K100-CM K125-150-CM K125-150-CM K200-CM K250-300-CM K250-300-CM K350-400-CM K350-400-CM -- -- Tear out inner section to convert to "open type" gasket. GK50-N GK50-V GK75-N GK75-V GK100-N GK100-V GK125-150-N GK125-150-V GK125-150-N GK125-150-V GK200-N GK200-V GK250-300-N GK-250-300-V GK250-300-N GK-250-300-V GK350-400-N GK-350-400-V GK350-400-N GK-350-400-V GK500-SN -- GK600-SN -- COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES Refer to previous page for Wiring Capacity Table. Not perforated. Visit our website at www.emerson.com or contact us at (800) 621-1506. 13 © January 2021 Form 35TM Malleable Iron Conduit Outlet Bodies, Covers and Gaskets Threaded Type for use with Rigid Metal Conduit and IMC; Compression Type for use with Threadless Rigid Metal Conduit. NEC/CEC -- Suitable for use in the following Hazardous Locations: Class I, Division 2 per NEC 501.10(B)(4) Threaded Type Dimensions in Millimeters (Inches) Types A, C, TA, TB Hub Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 A 100.1 (3.94) 117.6 (4.63) 136.7 (5.38) 182.6 (7.19) 182.6 (7.19) 241.3 (9.50) 311.2 (12.25) 311.2 (12.25) 378.0 (14.88) 378.0 (14.88) 463.6 (18.25) 584.2 (23.00) B 33.3 (1.31) 39.6 (1.56) 46.0 (1.81) 63.5 (2.50) 63.5 (2.50) 79.5 (3.13) 109.5 (4.31) 109.5 (4.31) 139.7 (5.50) 139.7 (5.50) 184.2 (7.25) 219.2 (8.63) C 36.6 (1.44) 42.9 (1.69) 49.3 (1.94) 65.0 (2.56) 69.9 (2.75) 85.9 (3.38) 98.6 (3.88) 117.6 (4.63) 131.8 (5.19) 141.2 (5.56) 177.8 (7.00) 220.7 (8.69) D 136.7 (5.38) 153.9 (6.06) 181.1 (7.13) 233.4 (9.19) 233.4 (9.19) 295.4 (11.63) 384.3 (15.13) 384.3 (15.13) 460.5 (18.13) 460.5 (18.13) -- -- E 68.3 (2.69) 73.2 (2.88) 85.9 (3.38) 114.3 (4.50) 114.3 (4.50) 133.4 (5.25) -- -- -- -- -- -- Types E, LB, LL, LR, LRL F 50.8 (2.00) 55.6 (2.19) 65.0 (2.56) 88.9 (3.50) 88.9 (3.50) 106.4 (4.19) 146.1 (5.75) 146.1 (5.75) 181.1 (7.13) 181.1 (7.13) -- -- G 54.1 (2.13) 58.7 (2.31) 68.3 (2.69) 90.4 (3.56) 95.3 (3.75) 117.6 (4.63) 133.4 (5.25) 152.4 (6.00) 173.0 (6.81) 182.6 (7.19) 228.6 (9.00) 271.5 (10.69) H 100.1 (3.94) 112.8 (4.44) 130.3 (5.13) 179.3 (7.06) 173.0 (6.81) 227.1 (8.94) 301.8 (11.88) 293.6 (11.56) 355.6 (14.00) 349.3 (13.75) 428.8 (16.88) 534.9 (21.06) J 117.6 (4.63) 136.7 (5.38) 158.8 (6.25) 208.0 (8.19) 208.0 (8.19) 268.2 (10.56) 347.7 (13.69) 347.7 (13.69) 419.1 (16.50) 419.1 (16.50) 514.4 (20.25) 635.0 (25.00) K 44.5 (1.75) 50.8 (2.00) 57.2 (2.25) 65.0 (2.56) 69.9 (2.75) 85.9 (3.38) 98.6 (3.88) 117.6 (4.63) 131.8 (5.19) 141.2 (5.56) -- -- Types T, X L 16.0 (0.63) 19.1 (0.75) 23.9 (0.94) 30.2 (1.19) 35.1 (1.38) 41.4 (1.63) 46.0 (1.81) 55.6 (2.19) 63.5 (2.50) 69.9 (2.75) 85.9 (3.38) 100.1 (3.94) M 30.2 (1.19) 35.1 (1.38) 42.9 (1.69) 50.8 (2.00) 60.5 (2.38) 74.7 (2.94) 85.9 (3.38) 104.9 (4.13) 120.7 (4.75) 130.3 (5.13) 165.1 (6.50) 192.0 (7.56) N 80.3 (3.16) 96.0 (3.78) 115.1 (4.53) 152.4 (6.00) 152.4 (6.00) 204.7 (8.06) 270.0 (10.63) 270.0 (10.63) 333.5 (13.13) 333.5 (13.13) 412.8 (16.25) 533.4 (21.00) P 25.4 (1.00) 31.0 (1.22) 37.3 (1.47) 50.8 (2.00) 50.8 (2.00) 65.0 (2.56) 93.7 (3.69) 93.7 (3.69) 124.0 (4.88) 124.0 (4.88) 165.1 (6.50) 198.4 (7.81) COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES 14 Visit our website at www.emerson.com or contact us at (800) 621-1506. © January 2021Adobe PDF Library 15.0