Rosemount 3051 Pressure Transmitter

This Product Data Sheet provides ordering information, specifications, product....certifications, and dimensional drawings of Rosemount 3051 Pressure....Transmitter.

00813-0100-4001, Rosemount, gauge pressure, low pressure regulator, pressure reducer, differential pressure cell, measurement of pressure, pressure products industries, pressure switch and pressure transmitter difference, measuring instrument for pressure, how to use pressure sensor, high temperature pressure transducer, what is a transducer, gas pressure sensor, absolute pressure sensor, what is differential pressure transmitter, transducers, pressure probe, pressure products, how differential pressure tra

Rosemount - Emerson

Rosemount 3051 Pressure Transmitter - Emerson Electric

April 2021 Rosemount™ 3051 Pressure Transmitter With the Rosemount 3051 Pressure Transmitter, you'll gain more control over your plant. You'll be able to reduce product variation and complexity as well as your total cost of ownership by leveraging one device across a number of pressure, level, and flow applications.

Rosemount 3051 Pressure Transmitter - Emerson

April 2021. Rosemount. ™. 3051 Pressure Transmitter. With the Rosemount 3051 Pressure Transmitter, you'll ... Rosemount 3051CF Flow Meter selection guide. ... Easy installation with all solutions fully assembled, leak-tested, and calibrated.

April 2021 Rosemount™ 3051 Pressure Transmitter With the Rosemount 3051 Pressure Transmitter, you'll gain more control over your plant. You'll be able to reduce product variation and complexity as well as your total cost of ownership by leveraging one device across a number of pressure, level, and flow applications.

product-data-sheet-rosemount-3051-pressure-products-en-73134
Product Data Sheet
00813-0100-4001, Rev WB April 2021
RosemountTM 3051 Pressure Transmitter
With the Rosemount 3051 Pressure Transmitter, you'll gain more control over your plant. You'll be able to reduce product variation and complexity as well as your total cost of ownership by leveraging one device across a number of pressure, level, and flow applications. You'll have access to information you can use to diagnose, correct, and even prevent issues. And with unparalleled reliability and experience, the Rosemount 3051 is the industry standard that will help you perform at higher levels of efficiency and safety so you can remain globally competitive.

Rosemount 3051

April 2021

Contents
Setting the standard for pressure measurement................................................................................................................................2 Rosemount 3051C Coplanar Pressure Transmitter ordering information........................................................................................... 6 Rosemount 3051T In-Line Transmitter ordering information...........................................................................................................19 Rosemount 3051CF Flow Meter selection guide.............................................................................................................................. 29 Rosemount 3051L Level Transmitter ordering information..............................................................................................................61 Specifications.................................................................................................................................................................................. 73 Rosemount 3051 product certifications.......................................................................................................................................... 91 Rosemount 3051 Wireless product certifications.......................................................................................................................... 107 Dimensional drawings .................................................................................................................................................................. 112 Options......................................................................................................................................................................................... 127

2

Emerson.com/Rosemount

April 2021

Rosemount 3051

Setting the standard for pressure measurement
Proven best-in-class performance, reliability, and safety
 More than seven million installed  Reference accuracy 0.04 percent of span  Installed total performance of 0.14 percent of span  10-year stability of 0.2 percent of URL  SIL2/3 certified (IEC 61508)

Maximize installation and application flexibility with the coplanar platform
 Improve reliability and performance with integrated DP Flow meters, DP Level solutions, and integral manifolds.  Easy installation with all solutions fully assembled, leak-tested, and calibrated.  Meet your application needs with an unsurpassed offering.
Advanced functionality
Loop Integrity diagnostics  Detect on-scale failures caused by electrical loop issues
before they impact your process operation.  This capability is safety certified for your most critical
applications. Local operator interface (LOI)  Straightforward menus and built-in configuration buttons
allow you to commission the device in less than a minute.  Configure in hazardous-area locations without removing the
transmitter cover using external buttons.

Emerson.com/Rosemount

3

Rosemount 3051

April 2021

Industry leading capabilities extended to IEC 62591 (WirelessHART®)
 Cost effectively implement wireless on the industry's most proven platform.
 Optimize safety with the industry's only intrinsically safe power module.
 Eliminate wiring design and construction complexities to lower costs by 40 to 60 percent.
 Quickly deploy new pressure, level, and flow measurements in 70 percent less time.

Innovative, integrated DP flow meters
 Fully assembled, configured, and leak tested for out-of-thebox installation.
 Reduce straight pipe requirements, lower permanent pressure loss, and achieve accurate measurement in small line sizes.
 Up to 1.65 percent volumetric flow accuracy at 8:1 turndown.

4

Emerson.com/Rosemount

April 2021

Rosemount 3051

Proven, reliable, and innovative DP Level technologies
 Connect to virtually any process with a comprehensive offering of process connections, fill fluids, direct mount, or capillary connections and materials.
 Quantify and optimize total system performance with QZ option.
 Operate at higher temperature and in vacuum applications.
 Optimize level measurement with cost efficient Rosemount Tuned-SystemTM assemblies.

Instrument manifolds ­ quality, convenient, and easy
 Designed and engineered for optimal performance with Rosemount transmitters.
 Save installation time and money with factory assembly.  Offers a variety of styles, materials, and configurations.

Access information when you need it with asset tags
Newly shipped devices include a unique QR code asset tag that enables you to access serialized information directly from the device. With this capability, you can:  Access device drawings, diagrams, technical documentation, and troubleshooting information in your MyEmerson account  Improve mean time to repair and maintain efficiency  Ensure confidence that you have located the correct device  Eliminate the time-consuming process of locating and transcribing nameplates to view asset information

Emerson.com/Rosemount

5

Rosemount 3051

April 2021

Rosemount 3051C Coplanar Pressure Transmitter ordering information

Rosemount 3051C Coplanar Pressure Transmitters are the industry standard for differential, gage, and absolute pressure measurement. The coplanar platform enables seamless integration with manifolds, flow, and level solutions. Capabilities include:  The Loop Integrity Diagnostic continuously monitors the
electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
 LOI with straightforward menus and built-in configuration buttons (option code M4).
 Safety certification (option code QT).

CONFIGURE >

VIEW PRODUCT >

Online product configurator
Many products are configurable online using our Product Configurator. Select the Configure button or visit our website to start. With this tool's built-in logic and continuous validation, you can configure your products more quickly and accurately.
Specifications and options
See the Specifications and options section for more details on each configuration. Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See the Material selection section for more information.
Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown in Figure 1. Figure 1: Model Code Example

1. Required model components (choices available on most) 2. Additional options (variety of features and functions that may be added to products)
Optimizing lead time
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

6

Emerson.com/Rosemount

April 2021

Rosemount 3051

Required model components

Model

Code Description

3051C Coplanar pressure transmitter



Measurement type

Code Description

D

Differential



G

Gage



A(1)

Absolute

(1) If ordered with Wireless output code X, only available with 316L stainless steel (SST) diaphragm material (code 2), and silicone fill fluid (code 1).

Pressure range

Code

Differential (Rosemount 3051CD)

Gage (Rosemount 3051CG)

Absolute (Rosemount 3051CA)

1

­25 to 25 inH2O

­25 to 25 inH2O

0 to 30 psia



(­62.16 to 62.16 mbar)

(­62.16 to 62.16 mbar)

(0 to 2.06 bar)

2

­250 to 250 inH2O

­250 to 250 inH2O

0 to 150 psia



(­621.60 to 621.60 mbar)

(­621.60 to 621.60 mbar)

(0 to 10.34 bar)

3

­1000 to 1000 inH2O

­393 to 1000 inH2O

0 to 800 psia



(­2.48 to 2.48 bar)

(­0.97 to 2.48 bar)

(0 to 55.15 bar

4

­300 to 300 psi

­14.2 to 300 psi

0 to 4000 psia



(­20.68 to 20.68 bar)

(­0.97 to 20.68 bar)

(0 to 275.79 bar)

5

­2000 to 2000 psi

­14.2 to 2000 psi

N/A



(­137.89 to 137.89 bar)

(­0.97 to 137.89 bar)

0(1)

­3 to 3 inH2O

N/A

N/A

(-7.46 to 7.46 mbar)

(1) Rosemount 3051CD0 is only available with output code A and X. For output code A, only transmitter flange code 0 (Alternate flange H2, H7, HJ, or HK), isolating diaphragm code 2, O ring code A, and bolting option L4 are available. For output code X, only transmitter flange code 0 (Alternate flange H2), isolating diaphragm code 2, O ring code A, and bolting option L4 are available.

Transmitter output

Code Description

A(1)

4­20 mA with digital signal based on HART® Protocol



F

FOUNDATIONTM Fieldbus Protocol



W(2)

PROFIBUS® PA Protocol



X(3)

Wireless (requires wireless options and engineered polymer housing)



Emerson.com/Rosemount

7

Rosemount 3051

April 2021

M(4)

Low-power, 1­5 Vdc with digital signal based on HART Protocol

(1) HART Revision 5 is the default HART output. (2) For local addressing and configuration, M4 (LOI) is required. Not available with product certification codes E4, EM, EP, I6, IM, KD, KL, KM, KP, KS,
N3. (3) This option is only available with intrinsically safe approvals. (4) Only available with C6, E2, E5, I5, K5, KB, EM , EP, and E8 product certifications.

Materials of construction

Code Transmitter flange type

Flange material

Drain/vent

2

Coplanar

3(1)

Coplanar

SST Cast C-276

SST



Alloy C-276



4

Coplanar

Alloy 400

Alloy 400/K-500



5

Coplanar

7(1)

Coplanar

8(1)

Coplanar

Plated CS SST Plated CS

SST



Alloy C-276



Alloy C-276



0

Alternate process connection



(1) Materials of construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Isolating diaphragm

Code Description

2(1)

316L SST



3(1)

Alloy C-276



4(2)

Alloy 400

5(2)

Tantalum (available on Rosemount 3051CD and CG, ranges 2­5 only; not available on Rosemount 3051CA)

6(2)

Gold-plated alloy 400 (use in combination with O-ring option code B)

7(2)

Gold-plated 316 SST

(1) Materials of construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(2) Not available with wireless output (code X).

O-ring

Code Description

A

Glass-filled PTFE



B

Graphite-filled PTFE



Sensor fill fluid

Code Description

1

Silicone



8

Emerson.com/Rosemount

April 2021

Rosemount 3051

2(1)

Inert (differential and gage only)



(1) Not available with wireless output (code X).

Housing material

Code Description

Conduit entry size

A

Aluminum

½­14 NPT



B

Aluminum

M20 x 1.5



E

Aluminum, ultra low copper

½­14 NPT



F

Aluminum, ultra low copper

M20 x 1.5



J

SST

½­14 NPT



K

SST

M20 x 1.5



P(1)

Engineered polymer

No conduit entries



D(2)

Aluminum

G½

M(2)

SST

G½

(1) Only available with wireless output (code X). (2) Transmitter conduit entry will be ½ NPT and a ½ NPT to G½ thread adapter will be provided. This option is only available with product
certifications options I1, I2, I3, I7, IA, IB, IM, KA, N1, N3, N7. Housing code D is also available with E4, and IG.

Wireless options
Requires wireless output code X and engineered polymer housing code P.

Wireless transmit rate, operating frequency, and protocol

Code Description

WA3 User configurable transmit rate, 2.4 GHz WirelessHART®



Antenna and SmartPowerTM

Code Description

WP5 Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)



Emerson.com/Rosemount

9

Rosemount 3051

April 2021

Additional options

Extended product warranty

Code Description

WR3 3-year limited warranty



WR5 5-year limited warranty



PlantwebTM control functionality

Code Description

A01

FOUNDATIONTM Fieldbus control function block suite



PlantwebTM diagnostic functionality

Code Description

DA0 Loop Integrity HART® Diagnostic



D01

FOUNDATIONTM Fieldbus Diagnostics Suite



Alternate flange
The alternate flange option code requires the 0 code in materials of construction for alternate process connection.

Code Description

H2

Traditional flange, 316 SST, SST drain/vent



H3(1) Traditional flange, alloy C, alloy C-276 drain/vent



H4

Traditional flange, cast alloy 400, alloy 400/K-500 drain/vent



H7(1) Traditional flange, 316 SST, alloy C-276 drain/vent



HJ

DIN-compliant traditional flange, SST, 7/16-in. (10 mm) adapter/manifold bolting



FA

Level flange, SST, 2-in. (51 mm), ANSI Class 150, vertical mount 316 SST drain/vent



FB

Level flange, SST, 2-in. (51 mm), ANSI Class 300, vertical mount 316 SST drain/vent



FC

Level flange, SST, 3-in. (76 mm), ANSI Class 150, vertical mount 316 SST drain/vent



FD

Level flange, SST, 3-in. (76 mm), ANSI Class 300, vertical mount 316 SST drain/vent



FP

DIN level flange, SST, DN 50, PN 40, vertical mount 316 SST drain/vent



FQ

DIN level flange, SST, DN 80, PN 40, vertical mount 316 SST drain/vent



HK(2) DIN compliant traditional flange, SST, 0.40 in. (10 mm) adapter/manifold bolting 316 SST

HL

DIN compliant traditional flange, SST, 0.50 in. (12 mm) adapter/manifold bolting 316 SST

(1) Materials of construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(2) Not valid with option code P9 for 4500 static pressure.

10

Emerson.com/Rosemount

April 2021

Rosemount 3051

Manifold assembly
"Assemble-to" items are specified separately and require a completed model number.

Code Description

S5

Assemble to Rosemount 305 Integral Manifold



S6

Assemble to Rosemount 304 Manifold or Connection System



Integral mount primary element
Not valid with option code P9 for 4500 static pressure. "Assemble-to" items are specified separately and require a completed model number.

Code Description

S3

Assemble to Rosemount 405 Compact Orifice Plate



S4(1) Assemble to Rosemount AnnubarTM or Rosemount 1195 Integral Orifice



(1) Transmitter flange limited to coplanar (option codes 2, 3, 5, 7, or 8) or traditional (option codes H2, H3, or H7).

Seal assemblies
"Assemble-to" items are specified separately and require a completed model number.

Code Description

S1(1) Assemble to one Rosemount 1199 seal



S2(2) Assemble to two Rosemount 1199 seals



(1) Not valid with option code D9 for RC½ adapters. (2) Not valid for option codes DF and D9 for adapters.

Mounting bracket
Panel mounting bolts are not supplied.

Code Description

B4

Coplanar flange bracket, all SST, 2-in. (51 mm) pipe and panel



B1

Traditional flange bracket, CS, 2-in. (51 mm) pipe



B2

Traditional flange bracket, CS, panel



B3

Traditional flange flat bracket, CS, 2-in. (51 mm) pipe



B7

Traditional flange bracket, B1 with SST bolts



B8

Traditional flange bracket, B2 with SST bolts



B9

Traditional flange bracket, B3 with SST bolts



BA

Traditional flange bracket, B1, all SST



BC

Traditional flange bracket, B3, all SST



Product certifications

Code Description

E8

ATEX Flameproof and Dust Certification



Emerson.com/Rosemount

11

Rosemount 3051

April 2021

I1(1)

ATEX Intrinsic Safety and Dust



IA

ATEX FISCO Intrinsic Safety; for FOUNDATIONTM Fieldbus or PROFIBUS® PA Protocol only



N1

ATEX Type n Certification and Dust



K8

ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)



E4

TIIS Flame-proof



I4

TIIS Intrinsic Safety



E5

USA Explosion-proof, Dust Ignition-Proof



I5(2)

USA Intrinsically Safe, Nonincendive



C6

Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2



E6

Canada Explosion-proof, Dust Ignition-proof, Division 2



I6

Canada Intrinsic Safety



K6

Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)



E7

IECEx Flameproof, Dust Ignition-proof



I7

IECEx Intrinsic Safety



N7

IECEx Type n Certification



K7

IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)



IG

IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K5

USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2



E2

INMETRO Flameproof001



I2

INMETRO Intrinsic Safety



IB

INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K2

INMETRO Flameproof, Intrinsic Safety



E3

China Flameproof



I3

China Intrinsic Safety



N3

China Type n



EM

Technical Regulations Customs Union (EAC) Flameproof



IM

Technical Regulations Customs Union (EAC) Intrinsic Safety



KM

Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety



KB

USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) 

KD

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)



KL(3) USA, Canada, IECEx, ATEX Intrinsic Safety Combination



KS

USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2



EP

Republic of Korea Flameproof



IP

Republic of Korea Intrinsic Safety



KP

Republic of Korea Flameproof, Intrinsic Safety



(1) Dust approval not applicable to output code X. (2) Nonincendive certification not provided with output code (X). (3) Only available with output code X.

12

Emerson.com/Rosemount

April 2021

Rosemount 3051

Drinking water approval
This approval is not available with Alloy C-276 isolator (code 3), tantalum isolator (code 5), all cast C-276 flanges, all plated carbon steel (CS) flanges, all DIN flanges, all level flanges, assemble-to manifolds (codes S5 and S6), assemble-to seals (codes S1 and S2), assemble-to primary elements (codes S3 and S4), surface finish certification (code Q16), and remote seal system report (code QZ).

Code Description

DW

NSF drinking water approval



Shipboard approvals
Shipyard approvals are not available with wireless output (code X).

Code Description

SBS

American Bureau of Shipping



SBV(1) Bureau Veritas (BV)



SDN Det Norske Veritas



SLL(1) Lloyds Register (LR)



(1) Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7

SST tagging

Code Y2

Description 316 SST nameplate, top tag, wire-on tag, and fasteners

Custody transfer
The custody transfer option is only available with HART 4­20 mA output (code A).

Code C5

Description Measurement Canada Accuracy Approval (limited availability depending on transmitter type and range; contact an  Emerson representative).

Bolting material

Code Description

L4(1) Austenitic 316 SST bolts



L5

ASTM A 193, grade B7M bolts



L6

Alloy K-500 bolts



(1) L4 bolting not required with S6 option.

Emerson.com/Rosemount

13

Rosemount 3051

Display and interface options

Code M4(1) M5

Description LCD display with LOI LCD display

(1) Only available with 4-20 mA HART® output (code A) and PROFIBUS®-PA (code W).

Calibration certificate

Code Q4 QG(1) QP

Description Calibration certificate Calibration certificate and GOST verification certificate Calibration certification and tamper evident seal

(1) Contact an Emerson representative for availability.

Material traceability certification

Code Q8

Description Material traceability certification per EN 10204 3.1

Positive material identification (PMI)

Code Q76

Description PMI verification and certificate

Quality certification for safety
The quality certification for safety is only available with HART® 4­20 mA output (code A).

Code QT

Description Safety certified to IEC 61508 with certificate of FMEDA

Configuration buttons

Code D4(1) DZ(2)

Description Analog zero and span Digital zero trim

(1) Only available with HART® 4­20 mA output (code A). (2) Only available with HART 4­20 mA output (output code A) and wireless output (output code X)

April 2021
 
  



 

14

Emerson.com/Rosemount

April 2021

Rosemount 3051

Transient protection
The transient protection option is not available with wireless output (code X). The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, and IE.

Code Description

T1

Transient protection terminal block



Software configuration
The software configuration option is only available with HART® 4­20 mA output (output code A) and wireless output (output code X).

Code Description

C1

Custom software configuration (For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see 

the Rosemount 3051 Wireless Configuration Data Sheet.)

Low power output

Code Description

C2

0.8­3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)



Gauge pressure calibration

Code Description

C3

Gauge calibration (Rosemount 3051CA only)



Alarm levels
The alarm levels option is only available with HART 4­20 mA output (code A).

Code C4(1) CN(1) CR CS CT

Description

Analog output levels compliant with NAMUR recommendation NE 43, alarm high



Analog output levels compliant with NAMUR recommendation NE 43, alarm low



Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Rosemount standard low alarm



(1) NAMUR-compliant operation is preset at the factory and can be changed to standard operation in the field for the standard Rosemount 3051.

Pressure testing

Code P1

Description Hydrostatic testing with certificate

Emerson.com/Rosemount

15

Rosemount 3051

April 2021

Cleaning process area

Code P2 P3(1)

Description Cleaning for special service Cleaning for < 1 ppm chlorine/fluorine

(1) Not available with code S5.

Flange adapters
This option is not valid with alternate process connection options S3, S4, S5, and S6.

Code Description

DF

½­14 NPT flange adapter(s)



Vent drain valves

Code D7 DC

Description Coplanar flange without drain/vent ports Ports left open - None

Conduit plug
The conduit plug option is not available with wireless output (code X).

Code Description

DO

316 SST conduit plug



RC¼ RC½ process connection
This option is not available with alternate process connection, DIN flanges, and level flanges.

Code D9

Description RC¼ flange with RC½ flange adapter - SST

Maximum static line pressure

Code Description

P9

4500 psig (310,26 bar) static pressure limit (Rosemount 3051CD ranges 2­5 only)



Ground screw
The ground screw option is not available with wireless output (code X). The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.

Code Description

V5

External ground screw assembly



16

Emerson.com/Rosemount

April 2021

Rosemount 3051

Surface finish

Code Description

Q16 Surface finish certification for sanitary remote seals



Toolkit total system performance reports

Code Description

QZ

Remote seal system performance calculation report



Conduit electrical connector
The conduit electrical connector option is not available with wireless output (code X).

Code Description

GE

M12, 4-pin, male connector (eurofast®)



GM

A size mini, 4-pin, male connector (minifast®)



NACE certificate
Note that NACE®-compliant wetted materials are required. Materials of construction must comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult the latest standard for details. All selected materials must also conform to NACE MR0103 for sour refining environments.

Code Description

Q15 Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials



Q25 Certificate of Compliance to NACE MR0103 for wetted materials



Cold temperature
This option is only available for pressure type D and G, pressure ranges 1­5 with 4-20 mA HART® protocol, and silicone sensor fill fluid. It is available with 316SST, C-276, gold plated SST isolating diaphragms, and with transmitter flange types 2, 7, and 0 (only for HJ, HK, and HL). BR5 and BR6 are not available with the following options: DC, DF, D7, D9, P9, Q16, GE, and GM. Consult factory for available approvals.

Code Description

BR5(1) ­58 °F (­50 °C) cold temperature operation



BR6(2) ­76 °F (­60 °C) cold temperature operation



(1) BR5 option is only available with approval codes C6, E2, E5, EM, I2, I5, I7, IM, IP, K5, KM, and KP. (2) BR6 option is only available with approval codes EM, I2, I7, IM, IP, and KM.

HART revision configuration (requires HART Protocol output code A)
HART® Revision 5 is the default HART output.

Code Description

HR5 Configured for HART Revision 5



HR7 Configured for HART Revision 7



Emerson.com/Rosemount

17

Rosemount 3051

Wireless power accessory
This option is only available with output code X.

Code Description

HS

Hot swap power adapter for power module replacement

April 2021

18

Emerson.com/Rosemount

April 2021

Rosemount 3051

Rosemount 3051T In-Line Transmitter ordering information

Rosemount 3051T In-Line Pressure Transmitters are the industry standard for gage and absolute pressure measurement. The in-line, compact design allows the transmitter to be connected directly to a process for quick, easy and cost effective installation. Capabilities include:  The Loop Integrity Diagnostic continuously monitors the
electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
 LOI with straightforward menus and built-in configuration buttons (option code M4).
 Safety certification (option code QT).

CONFIGURE >

VIEW PRODUCT >

Online product configurator
Many products are configurable online using our Product Configurator. Select the Configure button or visit our website to start. With this tool's built-in logic and continuous validation, you can configure your products more quickly and accurately.
Specifications and options
See the Specifications and options section for more details on each configuration. Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See the Material selection section for more information.
Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown in Figure 2. Figure 2: Model Code Example

1. Required model components (choices available on most) 2. Additional options (variety of features and functions that may be added to products)
Optimizing lead time
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

Emerson.com/Rosemount

19

Rosemount 3051

April 2021

Required model components

Model
Code Description 3051T In-Line Pressure Transmitter

Pressure type

Code Description

G

Gage



A(1)

Absolute



(1) Wireless output (code X) available in absolute measurement type (code A) with only range 1­5, with 14-NPT process connection (code 2B) and housing (code P).

Pressure range

Code Gage (Rosemount 3051TG)(1)

Absolute (Rosemount 3051TA)

0

­5 to 5 psi (-344.74 to 344.74 mbar)

N/A



1

­14.7 to 30 psi (-1.01 to 2.06 bar)

0 to 30 psia (0 to 2.06 bar)



2

­14.7 to 150 psi (-1.01 to 10.34 bar)

0 to 150 psia (0 to 10.34 bar)



3

­14.7 to 800 psi (-1.01 to 55.15 bar)

0 to 800 psia (0 to 55.15 bar)



4

­14.7 to 4000 psi (-1.01 to 275.79 bar)

0 to 4000 psia (0 to 275.79 bar)



5

­14.7 to 10000 psi (-1.01 to 689.47 bar)

0 to 10000 psia (0 to 689.47 bar)



6(2)

­14.7 to 20000 psi (­1.01 to 1378.95 bar)

0 to 20000 psia (0 to 1378.95 bar)

(1) Rosemount 3051TG lower range limit assumes atmospheric pressure of 14.7 psig. (2) Not available with PROFIBUS PA or Low Power 1­5 Vdc transmitter output (option code W or M), inert sensor fill fluid (option code 2), NSW
drinking water approval (option code DW), or assemble to manifolds (option code S5).

Transmitter output

Code Description

A(1)

4­20 mA with digital signal based on HART® Protocol



F

FOUNDATIONTM Fieldbus Protocol



W(2)

PROFIBUS® PA Protocol



X(3)

Wireless (requires wireless options and engineered polymer housing)



M(4)

Low-power, 1­5 Vdc with digital signal based on HART Protocol

(1) HART Revision 5 is the default HART output. (2) For local addressing and configuration, M4 (LOI) is required. Not available with product certification codes E4, EM, EP, I6, IM, KD, KL, KM, KP, KS,
N3. (3) This option is only available with intrinsically safe approvals. (4) Only available with C6, E2, E5, I5, K5, KB, EM , EP, and E8 product certifications.

20

Emerson.com/Rosemount

April 2021

Rosemount 3051

Process connection style

Code Description

2B

½-14 NPT female (range 1-5 only)



2C(1) G½ A EN837-1 male (range 1-4 only)



2F(2) Coned and threaded, compatible with autoclave Type F-250-C (range 5-6 only)

61(3)(4) Non-threaded instrument flange (range 1-4 only)

(1) Wireless output (code X), not available with absolute pressure type or C-276 diaphragm. Not available with S1, S5, or WSM. Only available in G½ A EN837-1 male process connection (code 2C) with range 1­4, 316 stainless steel isolating diaphragm (code 2), silicone fill fluid (code 1), and housing (code P).
(2) Not available with wireless output for range 5. (3) Not available with wireless output. (4) Only available with 316L stainless steel isolating diaphragm.

Isolating diaphragm
Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Code 2 3 7

Isolating diaphragm 316L stainless steel Alloy C-276 Gold-plated 316 stainless steel

Process connection wetted parts material

316L stainless steel



Alloy C-276



316L stainless steel

Sensor fill fluid

Code Description

1

Silicone



2(1)

Inert

(1) Not available with wireless output.

Housing material

Code Housing material

Conduit entry size

A

Aluminum

½-14 NPT



B

Aluminum

M20 x 1.5



E

Aluminum, ultra low copper

½-14 NPT

F

Aluminum, ultra low copper

M20 x 1.5

J

Stainless steel

½-14 NPT



K

Stainless steel

M20 x 1.5

P(1)

Engineered polymer

No conduit entries



D(2)

Aluminum

G½

M(2) Stainless steel

G½

(1) Only available with wireless output. Not available with absolute pressure type, range 1-4.

Emerson.com/Rosemount

21

Rosemount 3051

April 2021

(2) Transmitter conduit entry will be ½ NPT, and a ½ NPT to G½ thread adapter will be provided. Only available with product certifications options I1, I2, I3, I7, IA, IB, IM, KA, N1, N3, N7. Housing code D is also available with E4, and IG.

Wireless options
Requires wireless output code X and engineered polymer housing code P.

Wireless transmit rate, operating frequency, and protocol

Code Description

WA3 User configurable transmit rate, 2.4 GHz WirelessHART®



Antenna and SmartPower

Code Description

WP5 Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately).



Additional options

Extended product warranty

Code Description

WR3 3-year limited warranty



WR5 5-year limited warranty



PlantwebTM control functionality

Code Description

A01

FOUNDATIONTM Fieldbus control function block suite



PlantwebTM diagnostic functionality

Code Description

DA0 Loop Integrity HART® Diagnostic



D01

FOUNDATIONTM Fieldbus Diagnostics Suite



Integral assembly
"Assemble-to" items are specified separately and require a completed model number.

Code Description

S5

Assemble to Rosemount 306 Integral Manifold



22

Emerson.com/Rosemount

April 2021

Rosemount 3051

Diaphragm seal assemblies
"Assemble-to" items are specified separately and require a completed model number.

Code Description

S1

Assemble to one Rosemount 1199 seal



Mounting bracket
Panel mounting bolts are not supplied.

Code Description

B4

Bracket for 2-in. pipe or panel mounting, all stainless steel



Product certifications

Code Description

E8

ATEX Flameproof and Dust Certification



I1(1)

ATEX Intrinsic Safety and Dust



IA

ATEX FISCO Intrinsic Safety; for FOUNDATIONTM Fieldbus or PROFIBUS® PA Protocol only



N1

ATEX Type n Certification and Dust



K8

ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)



E4

TIIS Flame-proof



I4

TIIS Intrinsic Safety



E5

USA Explosion-proof, Dust Ignition-Proof



I5(2)

USA Intrinsically Safe, Nonincendive



C6

Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2



E6

Canada Explosion-proof, Dust Ignition-proof, Division 2



I6

Canada Intrinsic Safety



K6

Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)



E7

IECEx Flameproof, Dust Ignition-proof



I7

IECEx Intrinsic Safety



N7

IECEx Type n Certification



K7

IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)



IG

IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K5

USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2



E2

INMETRO Flameproof001



I2

INMETRO Intrinsic Safety



IB

INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K2

INMETRO Flameproof, Intrinsic Safety



E3

China Flameproof



I3

China Intrinsic Safety



Emerson.com/Rosemount

23

Rosemount 3051

April 2021

N3

China Type n



EM

Technical Regulations Customs Union (EAC) Flameproof



IM

Technical Regulations Customs Union (EAC) Intrinsic Safety



KM

Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety



KB

USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) 

KD

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)



KL(3) USA, Canada, IECEx, ATEX Intrinsic Safety Combination



KS

USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2



EP

Republic of Korea Flameproof



IP

Republic of Korea Intrinsic Safety



KP

Republic of Korea Flameproof, Intrinsic Safety



(1) Dust approval not applicable to output code X. (2) Nonincendive certification not provided with output code (X). (3) Only available with output code X.

Drinking water approval
Not available with alloy isolator (option code 3), assemble-to manifolds (option code S5), assemble-to seals (option code S1), surface finish certification (option code Q16), and remote seal system report (option code QZ).

Code Description

DW NSF drinking water approval



Shipboard approvals
Shipyard approvals are not available with wireless output (code X).

Code Description

SBS

American Bureau of Shipping



SBV(1) Bureau Veritas (BV)



SDN Det Norske Veritas



SLL(1) Lloyds Register (LR)



(1) Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7

SST tagging

Code Y2

Description 316 SST nameplate, top tag, wire-on tag, and fasteners

Custody transfer
The custody transfer option is only available with HART 4­20 mA output (code A).

24

Emerson.com/Rosemount

April 2021

Rosemount 3051

Code C5

Description Measurement Canada Accuracy Approval (limited availability depending on transmitter type and range; contact an  Emerson representative).

Calibration certification

Code Description

Q4

Calibration certificate



QG

Calibration certificate and GOST verification certificate



QP

Calibration certificate and tamper evident seal



Material traceability certification

Code Description

Q8

Material traceability certification per EN 10204 3.1.B



Positive material identification (PMI)

Code Description

Q76 PMI verification and certificate



Quality certification for safety
The quality certification for safety is only available with HART® 4­20 mA output (code A).

Code Description

QT

Safety certified to IEC 61508 with certificate of FMEDA



Configuration buttons

Code Description

D4(1) Analog zero and span



DZ(2) Digital zero trim



(1) Only available with HART 4­20 mA output (code A). (2) Only available with HART 4­20 mA output (output code A) and wireless output (output code X).

Display and interface options

Code Description

M4(1) LCD display with LOI



M5

LCD display



(1) Only available with 4-20 mA HART output (code A) and PROFIBUS-PA (code W).

Emerson.com/Rosemount

25

Rosemount 3051

April 2021

Wireless sensor module

Code Description

WSM Wireless stainless steel sensor module



Transient protection
The transient protection option is not available with wireless output (code X). The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, and IE.

Code Description

T1

Transient protection terminal block



Conduit plug
The conduit plug option is not available with wireless output (code X).

Code Description

DO

316 SST conduit plug



Software configuration

Code Description

C1

Custom software configuration. (Completed Rosemount 3051 Wireless Configuration Data Sheet required with



order.)

Low power output

Code Description

C2

0.8­3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)



Alarm levels
The alarm levels option is only available with HART 4­20 mA output (code A).

Code C4(1) CN(1) CR CS CT

Description

Analog output levels compliant with NAMUR recommendation NE 43, alarm high



Analog output levels compliant with NAMUR recommendation NE 43, alarm low



Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Rosemount standard low alarm



(1) NAMUR-compliant operation is preset at the factory and can be changed to standard operation in the field for the standard Rosemount 3051.

Pressure testing

Code Description

P1(1) Hydrostatic testing with certificate



(1) Not available with pressure range 0.

26

Emerson.com/Rosemount

April 2021

Rosemount 3051

Cleaning process area
Not valid with alternate process connection S5.

Code Description

P2

Cleaning for special service

P3

Cleaning for < 1 ppm chlorine/fluoride

Ground screw
The ground screw option is not available with wireless output (code X). The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.

Code Description

V5

External ground screw assembly



High accuracy
Only available with standard Rosemount 3051. See Specifications section for more information.

Code Description

P8

0.04% accuracy to 5:1 turndown (range 2-4)



Surface finish

Code Description

Q16 Surface finish certification for sanitary remote seals



Toolkit total system performance reports

Code Description

QZ

Remote seal system performance calculation report



Conduit electrical connector
The conduit electrical connector option is not available with wireless output (code X).

Code Description

GE

M12, 4-pin, male connector (eurofast®)



GM

A size mini, 4-pin, male connector (minifast®)



NACE certificate
Note that NACE®-compliant wetted materials are required. Materials of construction must comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult the latest standard for details. All selected materials must also conform to NACE MR0103 for sour refining environments.

Code Description

Q15 Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials



Q25 Certificate of Compliance to NACE MR0103 for wetted materials



Emerson.com/Rosemount

27

Rosemount 3051

April 2021

Cold temperature
This option is only available for pressure type D and G, pressure ranges 1­5 with 4-20 mA HART® protocol, and silicone sensor fill fluid. It is available with 316SST, C-276, gold plated SST isolating diaphragms, and with transmitter flange types 2, 7, and 0 (only for HJ, HK, and HL). BR5 and BR6 are not available with the following options: DC, DF, D7, D9, P9, Q16, GE, and GM. Consult factory for available approvals.

Code Description

BR5(1) ­58 °F (­50 °C) cold temperature operation



BR6(2) ­76 °F (­60 °C) cold temperature operation



(1) BR5 option is only available with approval codes C6, E2, E5, EM, I2, I5, I7, IM, IP, K5, KM, and KP. (2) BR6 option is only available with approval codes EM, I2, I7, IM, IP, and KM.

HART revision configuration (requires HART Protocol output code A)
HART® Revision 5 is the default HART output.

Code Description

HR5 Configured for HART Revision 5



HR7 Configured for HART Revision 7



Wireless power accessory
This option is only available with output code X.

Code HS

Description Hot swap power adapter for power module replacement

28

Emerson.com/Rosemount

April 2021

Rosemount 3051

Rosemount 3051CF Flow Meter selection guide
Rosemount 3051CF Flow Meters combine the proven Rosemount 3051 Pressure Transmitter and the latest primary element technologies. All flow meters are fully assembled, calibrated, configured, and leak tested for out-of-the-box installation and are available with wired or wireless capabilities to meet all of your application needs.
Rosemount 3051CFA Annubar Flow Meter
Rosemount Annubar technology minimizes permanent pressure loss while delivering best in class accuracy.  Lowest material costs for large line sizes.  Flo-tap enables installation without process shutdown.  Realize up to 96 percent less permanent pressure loss compared to traditional
orifice plate installations.

Rosemount 3051CFC Compact Conditioning Flow Meter
Rosemount Compact Conditioning technologies provide unprecedented performance with minimal straight-run requirements. Solutions include conditioning orifice plate or Rosemount Annubar primary elements.  Conditioning orifice requires only two pipe diameters upstream and downstream.
 Eliminate swirl and regular profiles resulting in more stable and accurate flow measurement.
 Savings up to 55 percent when compared to a traditional orifice plate installation can be realized.

Emerson.com/Rosemount

29

Rosemount 3051
Rosemount 3051CFP Integral Orifice Flow Meter

April 2021
Rosemount Integral Orifice Flow Meters deliver highly accurate small-bore flow measurement capability with minimal installation and maintenance requirements.  Best performance for small line sizes ½- to 1½-in. (15 to 40
mm).  Precision honed pipe section and tight machining
tolerances deliver higher installed performance.  Reduces uncertainty by up to five percent compared to
traditional orifice plate installation.

Rosemount 3051CFA AnnubarTM Flow Meter ordering information
The Rosemount 3051CFA Annubar Flow Meter uses the T-shaped sensor design that delivers best in class accuracy and performance while meeting the needs of diverse process applications, whether it is high accuracy for precision control or high strength for severe flow applications. Main capabilities include:  Up to 1.8 percent of flow rate accuracy.
 Available in 2- to 96-in. (50 to 2400 mm) line.
 Fully assembled and leak tested for out-of-the-box installation.
 The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
 LOI with straightforward menus and built-in configuration buttons (option code M4).
VIEW PRODUCT >

Online product configurator
Many products are configurable online using our Product Configurator. Select the Configure button or visit our website to start. With this tool's built-in logic and continuous validation, you can configure your products more quickly and accurately.
Specifications and options
See the Specifications and options section for more details on each configuration. Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See the Material selection section for more information.

30

Emerson.com/Rosemount

April 2021

Rosemount 3051

Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown in Figure 3.
Figure 3: Model Code Example

1. Required model components (choices available on most) 2. Additional options (variety of features and functions that may be added to products)

Optimizing lead time
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

Required model components
Model

Code

Description

3051CFA Annubar Flow Meter



Measurement type

Code Description

D

Differential pressure



Fluid type

Code Description

L

Liquid



G

Gas



S

Steam



Line size

Code Description

020 2-in. (50 mm)



025 2½-in. (63.5 mm)



030 3-in. (80 mm)



035 3½-in. (89 mm)



040 4-in. (100 mm)



050 5-in. (125 mm)



Emerson.com/Rosemount

31

Rosemount 3051

Code 060 070 080 100 120 140 160 180 200 240 300 360 420 480 600 720 780 840 900 960

Description 6-in. (150 mm) 7-in. (175 mm) 8-in. (200 mm) 10-in. (250 mm) 12-in. (300 mm) 14-in. (350 mm) 16-in. (400 mm) 18-in. (450 mm) 20-in. (500 mm) 24-in. (600 mm) 30-in. (750 mm) 36-in. (900 mm) 42-in. (1066 mm) 48-in. (1210 mm) 60-in. (1520 mm) 72-in. (1820 mm) 78-in. (1950 mm) 84-in. (2100 mm) 90-in. (2250 mm) 96-in. (2400 mm)

Pipe I.D. range

All pipe I.D. ranges are available for both measurement types D and 1-7.

Code Z

Description Specify pipe I.D. and wall thickness

Pipe material/mounting assembly material

All materials are available for both measurement types D and 1-7.

Code C S 0 G N J

Description CS (A105) 316 SST No mounting (customer supplied) Chrome-moly grade F-11 Chrome-moly grade F-22 Chrome-moly grade F-91

32

April 2021     

  
Emerson.com/Rosemount

April 2021

Piping orientation

Code H D U

Description Horizontal piping Vertical piping with downward flow Vertical piping with upward flow

Annubar type

Code P F L G M

Description Pak-Lok Flanged with opposite side support Flange-Lok Gear-drive Flo-Tap Manual Flo-Tap

Sensor material

Code S H

Description 316 SST Alloy C-276

Sensor size

Code 1 2 3

Description Sensor size 1 -- line sizes 2- to 8-in. (50 to 200 mm) Sensor size 2 -- line sizes 6- to 96-in. (150 to 2400 mm) Sensor size 3 -- line sizes greater than 12-in. (300 mm)

Mounting type

Code T1 A1 A3 A6 A9(1) AF(1) AT(1) D1

Description Compression or threaded connection Class 150 RF ASME B16.5 Class 300 RF ASME B16.5 Class 600 RF ASME B16.5 Class 900 RF ASME B16.5 Class 1500 RF ASME B16.5 Class 2500 RF ASME B16.5 PN16 EN-1092-1 RF

Emerson.com/Rosemount

Rosemount 3051
  
 

  
   
 33

Rosemount 3051

April 2021

Code Description

D3

PN40 EN-1092-1 RF



D6

PN100 EN-1092-1 RF



R1

Class 150 RTJ ASME B16.5

R3

Class 300 RTJ ASME B16.5

R6

Class 600 RTJ ASME B16.5

R9(1) Class 900 RTJ ASME B16.5

RF(1) Class 1500 RTJ ASME B16.5

RT(1) Class 2500 RTJ ASME B16.5

(1) Available in remote mount applications only.

Opposite side support or packing gland

Code Description

0

No opposite side support or packing gland (required for Pak-Lok and Flange-Lok models)



Opposite side support - required for flanged models

Code Description

C

NPT threaded opposite support assembly ­ extended tip



D

Welded opposite support assembly ­ extended tip



Packing gland - required for Flo-Tap models

Code J(1) K(1) L(1) N(1) R

Packing gland material SST packing gland/cage nipple Alloy C-276 packing gland/cage nipple

(1) The cage nipple is constructed of Rosemount 304 SST.

Isolation valve for Flo-Tap models

Code 0 1 2 5 6

Description Not applicable or customer supplied Gate valve, CS Gate valve, SST Ball valve, CS Ball valve, SST

Rod material CS SST CS SST SST

Packing material PTFE PTFE Graphite Graphite Graphite



34

Emerson.com/Rosemount

April 2021

Rosemount 3051

Temperature measurement

Code Description

T

Integral RTD ­ not available with flanged model greater than Class 600



0

No temperature sensor



R

Remote thermowell and RTD

Transmitter connection platform

Code Description

3

Direct-mount, integral 3-valve manifold­ not available with flanged model greater than Class 600



5

Direct-mount, 5-valve manifold ­ not available with flanged model greater than Class 600



7

Remote-mount NPT connections (½-in. NPT)



6

Direct-mount, high temperature 5-valve manifold ­ not available with flanged model greater than Class 600

8

Remote-mount SW connections (½-in.)

Differential pressure range

Code Description

1

0 to 25 in H2O (0 to 62.16 mbar)



2

0 to 250 in H2O (0 to 621.60 mbar)



3

0 to 1000 in H2O (0 to 2.49 bar)



Transmitter output

Code Description

A(1)

4­20 mA with digital signal based on HART® Protocol



F

FOUNDATIONTM Fieldbus Protocol



W(2)

PROFIBUS® PA Protocol



X(3)

Wireless (requires wireless options and engineered polymer housing)



M(4)

Low-power, 1­5 Vdc with digital signal based on HART Protocol

(1) HART Revision 5 is the default HART output. (2) For local addressing and configuration, M4 (LOI) is required. Not available with product certification codes E4, EM, EP, I6, IM, KD, KL, KM, KP, KS,
N3. (3) This option is only available with intrinsically safe approvals. (4) Only available with C6, E2, E5, I5, K5, KB, EM , EP, and E8 product certifications.

Housing material

Code Description

Conduit entry size

A

Aluminum

½­14 NPT



B

Aluminum

M20 x 1.5



E

Aluminum, ultra low copper

½­14 NPT



F

Aluminum, ultra low copper

M20 x 1.5



Emerson.com/Rosemount

35

Rosemount 3051

April 2021

J

SST

½­14 NPT



K

SST

M20 x 1.5



P(1)

Engineered polymer

No conduit entries



D(2)

Aluminum

G½

M(2)

SST

G½

(1) Only available with wireless output (code X). (2) Transmitter conduit entry will be ½ NPT and a ½ NPT to G½ thread adapter will be provided. This option is only available with product
certifications options I1, I2, I3, I7, IA, IB, IM, KA, N1, N3, N7. Housing code D is also available with E4, and IG.

Transmitter performance class

Code Description

1

1.75 percent flow rate accuracy, 8:1 flow turndown, 5-year stability



Wireless options

Wireless transmit rate, operating frequency, and protocol

Code Description

WA3 User configurable transmit rate, 2.4 GHz WirelessHART



Antenna and SmartPowerTM

Code Description

WP5 Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)



Additional options
Extended product warranty

Code Description

WR3 3-year limited warranty



WR5 5-year limited warranty



Pressure testing These options apply to assembled flow meter only, mounting not tested.

Code P1 PX

Description Hydrostatic testing with certificate Extended hydrostatic testing

Special cleaning

Code P2

Description Cleaning for special processes

36

Emerson.com/Rosemount

April 2021

Rosemount 3051

Material testing

Code V1

Description Dye penetrant exam

Material examination

Code V2

Description Radiographic examination

Flow calibration

Code W1

Description Flow calibration (Average K)

Special inspection

Code Description

QC1 Visual and dimensional inspection with certificate



QC7 Inspection and performance certificate



Surface finish This surface finish option is auto selected by the sizing tool as necessary.

Code Description

RL

Surface finish for low pipe Reynolds number in gas and steam



RH

Surface finish for high pipe Reynolds number in liquid



Material traceability certification
Instrument connections for remote mount options and isolation valves for Flo-Tap models are not included in the Material Traceability Certification.

Code Description

Q8

Material Traceability Certification per EN 10474:2004 3.1



Positive material identification (PMI)

Code Description

Q76 PMI verification and certificate



Code conformance This option is not available with transmitter connection platform 6.

Code J2

Description ANSI/ASME B31.1

Emerson.com/Rosemount

37

Rosemount 3051

April 2021

Code J3

Description ANSI/ASME B31.3

Materials conformance
Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Code J5

Description NACE MR-0175/ISO 15156

Country certification

Code Description

J6

European Pressure Directive (PED)



J1

Canadian registration

J8

Chinese Certificate of Special Equipment Type Test

Installed in flanged pipe spool section

Code H3 H4 H5

Description Class 150 flanged connection with Rosemount standard length and schedule Class 300 flanged connection with Rosemount standard length and schedule Class 600 flanged connection with Rosemount standard length and schedule

Instrument connections for remote mount options

Code Description

G2

Needle valves, SST



G6

OS&Y gate valves, SST



G1

Needle valves, CS

G3

Needle valves, alloy C-276

G5

OS&Y gate valves, CS

G7

OS&Y gate valves, alloy C-276

Special shipment

Code Description

Y1

Mounting hardware shipped separately



38

Emerson.com/Rosemount

April 2021

Rosemount 3051

Special dimensions

Code VM VT VS

Description Variable mounting Variable tip Variable length spool section

PlantwebTM control functionality

Code Description

A01

FOUNDATIONTM Fieldbus control function block suite



PlantwebTM diagnostic functionality

Code Description

DA0 Loop Integrity HART® Diagnostic



D01

FOUNDATIONTM Fieldbus Diagnostics Suite



Product certifications

Code Description

E8

ATEX Flameproof and Dust Certification



I1(1)

ATEX Intrinsic Safety and Dust



IA

ATEX FISCO Intrinsic Safety; for FOUNDATIONTM Fieldbus or PROFIBUS® PA Protocol only



N1

ATEX Type n Certification and Dust



K8

ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)



E4

TIIS Flame-proof



I4

TIIS Intrinsic Safety



E5

USA Explosion-proof, Dust Ignition-Proof



I5(2)

USA Intrinsically Safe, Nonincendive



C6

Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2



E6

Canada Explosion-proof, Dust Ignition-proof, Division 2



I6

Canada Intrinsic Safety



K6

Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)



E7

IECEx Flameproof, Dust Ignition-proof



I7

IECEx Intrinsic Safety



N7

IECEx Type n Certification



K7

IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)



IG

IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K5

USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2



E2

INMETRO Flameproof001



Emerson.com/Rosemount

39

Rosemount 3051

April 2021

I2

INMETRO Intrinsic Safety



IB

INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K2

INMETRO Flameproof, Intrinsic Safety



E3

China Flameproof



I3

China Intrinsic Safety



N3

China Type n



EM

Technical Regulations Customs Union (EAC) Flameproof



IM

Technical Regulations Customs Union (EAC) Intrinsic Safety



KM

Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety



KB

USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) 

KD

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)



KL(3) USA, Canada, IECEx, ATEX Intrinsic Safety Combination



KS

USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2



EP

Republic of Korea Flameproof



IP

Republic of Korea Intrinsic Safety



KP

Republic of Korea Flameproof, Intrinsic Safety



(1) Dust approval not applicable to output code X. (2) Nonincendive certification not provided with output code (X). (3) Only available with output code X.

Sensor fill fluid and O-ring options

Code Description

L1(1) Inert sensor fill fluid (silicone fill fluid is standard)



L2

Graphite-filled (PTFE) O-ring



LA(1) Inert sensor fill fluid and graphite-filled (PTFE) O-ring



(1) Not available with wireless output code X.

Shipboard approvals These options are not available with wireless output code X.

Code Description

SBS American Bureau of Shipping



SLL(1) Lloyds Register (LR)

(1) Only available with Product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, and N7.

Display and interface options

Code Description

M4(1) LCD display with LOI



M5

LCD display



(1) Not available with FOUNDATION Fieldbus (output code F) or Wireless (output code X) or low power (output code M).

40

Emerson.com/Rosemount

April 2021

Rosemount 3051

Transmitter calibration certification

Code Description

Q4

Calibration certificate for transmitter



Quality certification for safety These options are only available with 4­20 mA HART (output code A).

Code Description

QT

Safety certified to IEC 61508 with certificate of FMEDA



Transient protection
This option is not available with wireless output code X. The T1 option is not needed with FISCO Product Certifications; transient protection is included with the FISCO Product Certification codes IA, IB, and IE.

Code Description

T1

Transient terminal block



Manifold for remote mount option

Code Description

F2

3-valve manifold, SST



F6

5-valve manifold, SST



F3

3-valve manifold, alloy C-276

F7

5-valve manifold, alloy C-276

Lower power output

Code C2

Description 0.8­3.2 Vdc output with digital signal based on HART® Protocol (available with output code M only)

Alarm levels These options are only available with 4­20 mA HART (output code A).

Code C4(1) CN(1) CR CS CT

Description

NAMUR alarm and saturation levels, high alarm



NAMUR alarm and saturation levels, low alarm



Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Rosemount standard low alarm



(1) NAMUR-compliant operation is preset at the factory and can be changed to standard operation in the field for the standard Rosemount 3051.

Emerson.com/Rosemount

41

Rosemount 3051

April 2021

Configuration buttons

Code Description

D4(1) Analog zero and span



DZ(2) Digital zero trim



(1) Only available with 4­20 mA HART® (output code A). (2) Only available with 4­20 mA HART (output code A) and Wireless (output code X).

Ground screw
This option is not available with wireless output code X. The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.

Code Description

V5

External ground screw assembly



HART® Revision configuration
These options require HART Protocol output code A. Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.

Code Description

HR5 Configured for HART Revision 5



HR7 Configured for HART Revision 7



Rosemount 3051CFC Compact Flow Meter ordering information

Rosemount 3051CFC Compact Flow Meters provide a quick, reliable installation between existing raised face flanges. Depending on your application needs, you can reduce energy loss with the Compact AnnubarTM or minimize straight run requirements with the Conditioning Orifice.  Up to 1.8 percent of flow rate accuracy.
 Available in ½- to 12-in. (15 to 300 mm) line sizes.
 Fully assembled and leak tested for out-of-the-box installation.
 The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
 LOI with straightforward menus and built-in configuration buttons (option code M4).

CONFIGURE >

VIEW PRODUCT >

Online product configurator
Many products are configurable online using our Product Configurator. Select the Configure button or visit our website to start. With this tool's built-in logic and continuous validation, you can configure your products more quickly and accurately.

42

Emerson.com/Rosemount

April 2021

Rosemount 3051

Specifications and options
See the Specifications and options section for more details on each configuration. Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See the Material selection section for more information.
Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown in Figure 4. Figure 4: Model Code Example

1. Required model components (choices available on most) 2. Additional options (variety of features and functions that may be added to products)

Optimizing lead time
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

Required model components
Model

Code

Description

3051CFC Compact flow meter



Measurement type

Code Description

D

Differential pressure



Primary element technology

Code Description

A

Annubar averaging pitot tube



C

Conditioning orifice plate



P

Orifice plate



Material type

Code Description

S

316 SST



Emerson.com/Rosemount

43

Rosemount 3051

Line size

Code 005(1) 010 (1) 015(1) 020 030 040 060 080 100(2) 120(2)

Product description ½-in. (15 mm) 1-in. (25 mm) 1½-in. (40 mm) 2-in. (50 mm) 3-in. (80 mm) 4-in. (100 mm) 6-in. (150 mm) 8-in. (200 mm) 10-in. (250 mm) 12-in. (300 mm)

(1) Available with Primary Element Technology P only. (2) 10-in. (250 mm) and 12-in. (300 mm) line sizes not available with Primary Element Technology A.

Primary element type

Code Description N000 Rosemount Annubar sensor size 1 N040 0.40 beta ratio N050 0.50 beta ratio N065(1) 0.65 beta ratio

(1) For 2-in. (50 mm) line sizes the Primary Element Type is 0.6 for Primary Element Technology Code C.

Temperature measurement

Code T(1) 0 R

Description Integral temperature No temperature sensor Remote thermowell and RTD

(1) Available with primary element technology A only.

Transmitter connection platform

Code 3 7

Description Direct-mount Remote-mount, NPT connections

Differential pressure range

Code 1 2

Description 0 to 25 in H2O (0 to 62.16 mbar) 0 to 250 in H2O (0 to 621.60 mbar)

44

April 2021
         
  

 
  Emerson.com/Rosemount

April 2021

Rosemount 3051

Code Description

3

0 to 1000 in H2O (0 to 2.49 bar)



Transmitter output

Code Description

A(1)

4­20 mA with digital signal based on HART® Protocol



F

FOUNDATIONTM Fieldbus Protocol



W(2)

PROFIBUS® PA Protocol



X(3)

Wireless (requires wireless options and engineered polymer housing)



M(4)

Low-power, 1­5 Vdc with digital signal based on HART Protocol

(1) HART Revision 5 is the default HART output. (2) For local addressing and configuration, M4 (LOI) is required. Not available with product certification codes E4, EM, EP, I6, IM, KD, KL, KM, KP, KS,
N3. (3) This option is only available with intrinsically safe approvals. (4) Only available with C6, E2, E5, I5, K5, KB, EM , EP, and E8 product certifications.

Housing material

Code Description

Conduit entry size

A

Aluminum

½­14 NPT



B

Aluminum

M20 x 1.5



E

Aluminum, ultra low copper

½­14 NPT



F

Aluminum, ultra low copper

M20 x 1.5



J

SST

½­14 NPT



K

SST

M20 x 1.5



P(1)

Engineered polymer

No conduit entries



D(2)

Aluminum

G½

M(2)

SST

G½

(1) Only available with wireless output (code X). (2) Transmitter conduit entry will be ½ NPT and a ½ NPT to G½ thread adapter will be provided. This option is only available with product
certifications options I1, I2, I3, I7, IA, IB, IM, KA, N1, N3, N7. Housing code D is also available with E4, and IG.

Transmitter performance class

Code Description

1

Up to ±1.75% flow rate accuracy, 8:1 flow turndown, 5-year stability



Wireless options

These options require wireless output code X and Engineered Polymer Housing code P. Wireless transmit rate, operating frequency, and protocol

Code Description

WA3 User configurable transmit rate, 2.4 GHz WirelessHART®



Emerson.com/Rosemount

45

Rosemount 3051

Antenna and SmartPower

Code WP5

Description Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)

Additional options
Extended product warranty

Code WR3 WR5

Description 3-year limited warranty 5-year limited warranty

Installation accessories

Code AB AC AD DG DH DJ JB JR JS

Description ANSI alignment ring (Class 150) (only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes) ANSI alignment ring (Class 300) (only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes) ANSI alignment ring (Class 600) (only required for 10-in. (250 mm) and 12-in. (300 mm) line sizes) DIN alignment ring (PN16) DIN alignment ring (PN40) DIN alignment ring (PN100) JIS alignment ring (10K) JIS alignment ring (20K) JIS alignment ring (40K)

Remote adapters

Code FE

Description Flange adapters 316 SST (½-in NPT)

High temperature application

Code HT

Description Graphite valve packing (Tmax = 850 °F)

Flow calibration Available with Primary Element Technology C only.

Code WC WD(1)

Description Flow calibration, 3 pt, conditioning orifice option C (all pipe schedules) Flow calibration, 10 pt, conditioning option C (all schedules), Annubar option A (schedule 40)

(1) For Annubar option A, consult factory for pipe schedules other than schedule 40.

April 2021

 
     


46

Emerson.com/Rosemount

April 2021

Pressure testing

Code P1

Description Hydrostatic testing with certificate

Special cleaning Available with Primary Element Technology C or P only.

Code P2

Description Cleaning for special processes

Special inspection

Code QC1 QC7

Description Visual and dimensional inspection with certificate Inspection and performance certificate

Transmitter calibration certification

Code Q4

Description Calibration certificate for transmitter

Quality certification for safety Only available with HART® 4­20 mA output code A.

Code QT

Description Safety certified to IEC 61508 with certificate of FMEDA

Material traceability certification

Code Q8

Description Material traceability certification per EN 10204:2004 3.1

Positive material identification (PMI)

Code Q76

Description PMI verification and certificate

Code conformance

Code J2 J3 J4

Description ANSI/ASME B31.1 ANSI/ASME B31.3 ANSI/ASME B31.8

Emerson.com/Rosemount

Rosemount 3051
     
47

Rosemount 3051

April 2021

Materials conformance
Materials of construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Code J5

Description NACE MR-0175/ISO 15156

Country certification

Code J1

Description Canadian registration

Product certifications

Code Description

E8

ATEX Flameproof and Dust Certification



I1(1)

ATEX Intrinsic Safety and Dust



IA

ATEX FISCO Intrinsic Safety; for FOUNDATIONTM Fieldbus or PROFIBUS® PA Protocol only



N1

ATEX Type n Certification and Dust



K8

ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)



E4

TIIS Flame-proof



I4

TIIS Intrinsic Safety



E5

USA Explosion-proof, Dust Ignition-Proof



I5(2)

USA Intrinsically Safe, Nonincendive



C6

Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2



E6

Canada Explosion-proof, Dust Ignition-proof, Division 2



I6

Canada Intrinsic Safety



K6

Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)



E7

IECEx Flameproof, Dust Ignition-proof



I7

IECEx Intrinsic Safety



N7

IECEx Type n Certification



K7

IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)



IG

IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K5

USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2



E2

INMETRO Flameproof001



I2

INMETRO Intrinsic Safety



IB

INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K2

INMETRO Flameproof, Intrinsic Safety



E3

China Flameproof



48

Emerson.com/Rosemount

April 2021

Rosemount 3051

I3

China Intrinsic Safety



N3

China Type n



EM

Technical Regulations Customs Union (EAC) Flameproof



IM

Technical Regulations Customs Union (EAC) Intrinsic Safety



KM

Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety



KB

USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) 

KD

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)



KL(3) USA, Canada, IECEx, ATEX Intrinsic Safety Combination



KS

USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2



EP

Republic of Korea Flameproof



IP

Republic of Korea Intrinsic Safety



KP

Republic of Korea Flameproof, Intrinsic Safety



(1) Dust approval not applicable to output code X. (2) Nonincendive certification not provided with output code (X). (3) Only available with output code X.

Sensor fill fluid and O-ring options

Code Description

L1(1) Inert sensor fill fluid



L2

Graphite-filled (PTFE) O-ring



LA(1) Inert sensor fill fluid and graphite-filled (PTFE) O-ring



(1) Not available with Wireless output code X.

Shipboard approvals Not available with wireless output code X.

Code Description

SBS

American Bureau of Shipping



SLL(1) Lloyds Register (LR)



(1) Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, and N7.

Display and interface options

Code Description

M4(1) LCD display with LOI



M5

LCD display



(1) Not available with output code F- FOUNDATION Fieldbus or Wireless output code X or low power (output code M).

Transient protection
The T1 option is not needed with FISCO Product Certifications; transient protection is included with the FISCO Product Certification code IA, IB, and IE.

Code Description

T1

Transient terminal block



Emerson.com/Rosemount

49

Rosemount 3051

April 2021

Manifold for remote mount option

Code Description

F2

3-valve manifold, SST



F6

5-Valve Manifold, SST



PlantwebTM control functionality

Code Description

A01

FOUNDATIONTM Fieldbus control function block suite



PlantwebTM diagnostic functionality

Code Description

DA0 Loop Integrity HART® Diagnostic



D01

FOUNDATIONTM Fieldbus Diagnostics Suite



Low power output

Code C2

Description 0.8­3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)

Alarm levels Only available with HART 4­20 mA output code A.

Code C4(1) CN(1) CR CS CT

Description

NAMUR alarm and saturation levels, high alarm



NAMUR alarm and saturation levels, low alarm



Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Rosemount standard low alarm



(1) NAMUR-compliant operation is preset at the factory and can be changed to standard operation in the field for the standard Rosemount 3051.

Ground screw The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.

Code Description

V5

External ground screw assembly



Configuration buttons

Code D4(1) DZ(2)

Description Analog zero and span Digital zero trim

(1) Only available with HART 4­20 mA output code A.

50

 
Emerson.com/Rosemount

April 2021

Rosemount 3051

(2) Only available with 4­20 mA HART output code A and wireless output code X.
HART® Revision Configuration (requires HART Protocol output code A)
Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.

Code Description

HR5 Configured for HART Revision 5



HR7 Configured for HART Revision 7



Rosemount 3051CFP Integral Orifice Flow Meter ordering information
Rosemount 3051CFP Integral Orifice Flow Meters enable highly accurate flow measurement in small line sizes. Integral Orifice Flow Meters use precision honed pipe section for increased accuracy and self-centering plate design to prevent alignment errors that magnify measurement inaccuracies in small line sizes.  Up to 1.75 percent of flow rate accuracy.  Available in ½- to 1½-in. (15 - 40 mm) line sizes.  Fully assembled and leak tested for out-of-the-box
installation.  The Loop Integrity Diagnostic continuously monitors the
electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).  LOI with straightforward menus and built-in configuration buttons (option code M4).
VIEW PRODUCT >
Online product configurator
Many products are configurable online using our Product Configurator. Select the Configure button or visit our website to start. With this tool's built-in logic and continuous validation, you can configure your products more quickly and accurately.
Specifications and options
See the Specifications and options section for more details on each configuration. Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See the Material selection section for more information.
Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown in Figure 5.
Figure 5: Model Code Example

1. Required model components (choices available on most)

Emerson.com/Rosemount

51

Rosemount 3051

April 2021

2. Additional options (variety of features and functions that may be added to products)

Optimizing lead time
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

Required model components
Model

Code

Description

3051CFP Integral Orifice Flow Meter



Measurement type

Code Product description

D

Differential pressure



Body material

Code Description

F

316 SST, 4-bolt



Line size

Code Description

005

½-in. (15 mm)



010

1-in. (25 mm)



015

1½-in. (40 mm)



Process connection

Code Description

T1

NPT female body (not available with remote thermowell and RTD)



S1(1) Socket weld body (not available with remote thermowell and RTD)



P1

Pipe ends: NPT threaded



P2

Pipe ends: beveled



D1

Pipe ends: flanged, PN16 EN-1092-1 RF, slip-on



D2

Pipe ends: flanged, PN40 EN-1092-1 RF, slip-on



D3

Pipe ends: flanged, PN100 EN-1092-1 RF, slip-on



W1

Pipe ends: flanged, RF, Class 150 RF ASME B16.5, weld-neck



W3

Pipe ends: flanged, RF, Class 300 RF ASME B16.5, weld-neck



W6

Pipe ends: flanged, RF, Class 600 RF ASME B16.5, weld-neck



52

Emerson.com/Rosemount

April 2021

Code W9 A1 A3 A6 R1 R3 R6 R9

Description Pipe ends: flanged, Class 900 RF ASME B16.5, weld-neck Pipe ends: flanged, RF, Class 150 RF ASME B16.5, slip-on Pipe ends: flanged, RF, Class 300 RF ASME B16.5, slip-on Pipe ends: flanged, RF, Class 600 RF ASME B16.5, slip-on Pipe ends: flanged, RTJ, Class 150 RTJ ASME B16.5, slip-on Pipe ends: flanged, RTJ, Class 300 RTJ ASME B16.5, slip-on Pipe ends: flanged, RTJ, Class 600 RTJ ASME B16.5, slip-on Pipe ends: flanged, Class 900 RTJ ASME B16.5, weld-neck

(1) To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D.

Orifice plate material

Code S H M

Description 316 SST Alloy C-276 Alloy 400

Bore size option

Code 0066 0109 0160 0196 0260 0340 0150 0250 0345 0500 0630 0800 0295 0376 0512 0748 1022 1184

Description 0.066-in. (1.68 mm) for ½-in. pipe 0.109-in. (2.77 mm) for ½-in. pipe 0.160-in. (4.06 mm) for ½-in. pipe 0.196-in. (4.98 mm) for ½-in. pipe 0.260-in. (6.60 mm) for ½-in. pipe 0.340-in. (8.64 mm) for ½-in. pipe 0.150-in. (3.81 mm) for 1-in. pipe 0.250-in. (6.35 mm) for 1-in. pipe 0.345-in. (8.76 mm) for 1-in. Pipe 0.500-in. (12.70 mm) for 1-in. pipe 0.630-in. (16.00 mm) for 1-in. pipe 0.800-in. (20.32 mm) for 1-in. pipe 0.295-in. (7.49 mm) for 1½-in. pipe 0.376-in. (9.55 mm) for 1½-in. pipe 0.512-in. (13.00 mm) for 1½-in. pipe 0.748-in. (19.00 mm) for 1½-in. pipe 1.022-in. (25.96 mm) for 1½-in. pipe 1.184-in. (30.07 mm) for 1½-in. pipe

Emerson.com/Rosemount

Rosemount 3051

                  53

Rosemount 3051

April 2021

Code 0010 0014 0020 0034

Description 0.010-in. (0.25 mm) for ½-in. pipe 0.014-in. (0.36 mm) for ½-in. pipe 0.020-in. (0.51 mm) for ½-in. pipe 0.034-in. (0.86 mm) for ½-in. pipe

Transmitter connection platform

Code Description

D3

Direct-mount, 3-valve manifold, SST



D5

Direct-mount, 5-valve manifold, SST



R3

Remote-mount, 3-valve manifold, SST



R5

Remote-mount, 5-valve manifold, SST

D4

Direct-mount, 3-valve manifold, alloy C-276

D6

Direct-mount, 5-valve manifold, alloy C-276

D7

Direct-mount, high temperature, 5-valve manifold, SST

R4

Remote-mount, 3-valve manifold, alloy C-276

R6

Remote-mount, 5-valve manifold, alloy C-276

Differential pressure range

Code Description

1

0 to 25 in H2O (0 to 62.16 mbar)



2

0 to 250 in H2O (0 to 621.60 mbar)



3

0 to 1000 in H2O (0 to 2.49 bar)



Transmitter output

Code Description

A(1)

4­20 mA with digital signal based on HART® Protocol



F

FOUNDATIONTM Fieldbus Protocol



W(2)

PROFIBUS® PA Protocol



X(3)

Wireless (requires wireless options and engineered polymer housing)



M(4)

Low-power, 1­5 Vdc with digital signal based on HART Protocol

(1) HART Revision 5 is the default HART output. (2) For local addressing and configuration, M4 (LOI) is required. Not available with product certification codes E4, EM, EP, I6, IM, KD, KL, KM, KP, KS,
N3. (3) This option is only available with intrinsically safe approvals. (4) Only available with C6, E2, E5, I5, K5, KB, EM , EP, and E8 product certifications.

54

Emerson.com/Rosemount

April 2021

Rosemount 3051

Housing material

Code Description

Conduit entry size

A

Aluminum

½­14 NPT



B

Aluminum

M20 x 1.5



E

Aluminum, ultra low copper

½­14 NPT



F

Aluminum, ultra low copper

M20 x 1.5



J

SST

½­14 NPT



K

SST

M20 x 1.5



P(1)

Engineered polymer

No conduit entries



D(2)

Aluminum

G½

M(2)

SST

G½

(1) Only available with wireless output (code X). (2) Transmitter conduit entry will be ½ NPT and a ½ NPT to G½ thread adapter will be provided. This option is only available with product
certifications options I1, I2, I3, I7, IA, IB, IM, KA, N1, N3, N7. Housing code D is also available with E4, and IG.

Transmitter performance class

Code Description

1

Up to ±1.75% flow rate accuracy, 8:1 flow turndown, 5-year stability



Wireless options
These options require wireless output code X and engineered polymer housing code P. Wireless transmit rate, operating frequency, and protocol

Code Description

WA3 User configurable transmit rate, 2.4 GHz WirelessHART®



Antenna and SmartPower

Code Description

WP5 Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)



Additional options
Extended product warranty

Code Description

WR3 3-year limited warranty



WR5 5-year limited warranty



Transmitter body/bolt material

Code GT

Description High temperature (850 °F/454 °C)

Emerson.com/Rosemount

55

Rosemount 3051

Temperature sensor Thermowell material is the same as the body material.

Code RT

Description Thermowell and RTD

Optional connection

Code G1

Description DIN 19213 transmitter connection

Pressure testing This option does not apply to process connection codes T1 and S1.

Code P1

Description Hydrostatic testing with certificate

Special cleaning

Code P2

Description Cleaning for special services

Material testing

Code V1

Description Dye penetrant exam

Material examination

Code V2

Description Radiographic examination

Flow calibration This option is not available for bore sizes 0010, 0014, 0020, 0034, 0066, or 0109.

Code WD

Description Discharge coefficient verification

Special inspection

Code QC1 QC7

Description Visual and dimensional inspection with certificate Inspection and performance certificate

56

April 2021 
  Emerson.com/Rosemount

April 2021

Rosemount 3051

Material traceability certification

Code Description

Q8

Material traceability certification per EN 10204:2004 3.1



Positive material identification (PMI)

Code Description

Q76 PMI verification and certificate



Code conformance This option is not available with DIN Process Connection codes D1, D2, or D3.

Code J2 J3 J4

Description ANSI/ASME B31.1 ANSI/ASME B31.3 ANSI/ASME B31.8

Materials conformance
Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Code J5

Description NACE MR-0175/ISO 15156

Country certification

Code Description

J1

Canadian registration



J6

European Pressure Directive (PED)



Transmitter calibration certification

Code Description

Q4

Calibration certificate for transmitter



Quality certification for safety This option is only availabe with HART® 4-20 mA output (option code A).

Code Description

QT

Safety certified to IEC 61508 with certificate of FMEDA



Emerson.com/Rosemount

57

Rosemount 3051

April 2021

Product certifications

Code E8 I1(1) IA N1 K8 E4 I4 E5 I5(2) C6 E6 I6 K6 E7 I7 N7 K7 IG K5 E2 I2 IB K2 E3 I3 N3 EM IM KM KB KD KL(3) KS EP IP

Description

ATEX Flameproof and Dust Certification



ATEX Intrinsic Safety and Dust



ATEX FISCO Intrinsic Safety; for FOUNDATIONTM Fieldbus or PROFIBUS® PA Protocol only



ATEX Type n Certification and Dust



ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)



TIIS Flame-proof



TIIS Intrinsic Safety



USA Explosion-proof, Dust Ignition-Proof



USA Intrinsically Safe, Nonincendive



Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2



Canada Explosion-proof, Dust Ignition-proof, Division 2



Canada Intrinsic Safety



Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)



IECEx Flameproof, Dust Ignition-proof



IECEx Intrinsic Safety



IECEx Type n Certification



IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)



IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2



INMETRO Flameproof001



INMETRO Intrinsic Safety



INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



INMETRO Flameproof, Intrinsic Safety



China Flameproof



China Intrinsic Safety



China Type n



Technical Regulations Customs Union (EAC) Flameproof



Technical Regulations Customs Union (EAC) Intrinsic Safety



Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety



USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) 

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)



USA, Canada, IECEx, ATEX Intrinsic Safety Combination



USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2



Republic of Korea Flameproof



Republic of Korea Intrinsic Safety



58

Emerson.com/Rosemount

April 2021

Rosemount 3051

KP

Republic of Korea Flameproof, Intrinsic Safety



(1) Dust approval not applicable to output code X. (2) Nonincendive certification not provided with output code (X). (3) Only available with output code X.

Sensor fill fluid and O-ring options

Code Description

L1(1) Inert sensor fill fluid (silicone fill fluid is standard)



L2

Graphite-filled (PTFE) O-ring



LA(1) Inert sensor fill fluid and graphite-filled (PTFE) O-ring



(1) Not available with wireless output code X.

Shipboard approvals These options are not available with wireless output code X.

Code Description

SBS American Bureau of Shipping



SLL(1) Lloyds Register (LR)

(1) Only available with Product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, and N7.

Display and interface options

Code Description

M4(1) LCD display with LOI



M5

LCD display

(1) Not available with output code F- FOUNDATION Fieldbus or Wireless output code X or low power (output code M).

Transient protection
The T1 option is not needed with FISCO Product Certifications; transient protection is included with the FISCO Product Certification code IA, IB, and IE.

Code Description

T1

Transient terminal block



PlantwebTM control functionality

Code Description

A01

FOUNDATIONTM Fieldbus control function block suite



PlantwebTM diagnostic functionality

Code Description

DA0 Loop Integrity HART® Diagnostic



D01

FOUNDATIONTM Fieldbus Diagnostics Suite



Emerson.com/Rosemount

59

Rosemount 3051

April 2021

Low power output

Code C2

Description 0.8­3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)

Alarm levels Only available with HART 4­20 mA output code A.

Code C4(1) CN(1) CR CS CT

Description

NAMUR alarm and saturation levels, high alarm



NAMUR alarm and saturation levels, low alarm



Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Rosemount standard low alarm



(1) NAMUR-compliant operation is preset at the factory and can be changed to standard operation in the field for the standard Rosemount 3051.

Ground screw The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.

Code Description

V5

External ground screw assembly



Configuration buttons

Code Description

D4(1) Analog zero and span



DZ(2) Digital zero trim



(1) Only available with HART 4­20 mA output code A. (2) Only available with 4­20 mA HART output code A and wireless output code X.

HART® Revision Configuration (requires HART Protocol output code A)

Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.

Code Description

HR5 Configured for HART Revision 5



HR7 Configured for HART Revision 7



60

Emerson.com/Rosemount

April 2021

Rosemount 3051

Rosemount 3051L Level Transmitter ordering information

The Rosemount 3051L Level Transmitter combines the performance and capabilities of Rosemount 3051 Transmitters with the reliability and quality of a direct mount seal in one model number. Rosemount 3051L Level Transmitters offer a variety of process connections, configurations, and fill fluid types to meet a breadth of level applications. Capabilities of a Rosemount 3051L Level Transmitter include:  Quantify and optimize total system performance (option
code QZ).
 Tuned-System assembly (option code S1).
 The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
 LOI with straightforward menus and built-in configuration buttons (option code M4).

CONFIGURE >

VIEW PRODUCT >

Online product configurator
Many products are configurable online using our Product Configurator. Select the Configure button or visit our website to start. With this tool's built-in logic and continuous validation, you can configure your products more quickly and accurately.
Specifications and options
See the Specifications and options section for more details on each configuration. Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See the Material selection section for more information.
Model codes
Model codes contain the details related to each product. Exact model codes will vary; an example of a typical model code is shown in Figure 6. Figure 6: Model Code Example

1. Required model components (choices available on most) 2. Additional options (variety of features and functions that may be added to products)

Emerson.com/Rosemount

61

Rosemount 3051

April 2021

Optimizing lead time
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead time.

Required model components

Model

Code Description

3051L Level transmitter



Pressure range

Code Description

2

­250 to 250 inH2O (­621.60 to 621.60 mbar)



3

­1000 to 1000 inH2O (­2.48 to 2.48 bar)



4

­300 to 300 psi (­20.68 to 20.68 bar)



Transmitter output

Code Description

A(1)

4­20 mA with digital signal based on HART® Protocol



F

FOUNDATIONTM Fieldbus Protocol



W(2)

PROFIBUS® PA Protocol



X(3)

Wireless (requires wireless options and engineered polymer housing)



M(4)

Low-power, 1­5 Vdc with digital signal based on HART Protocol

(1) HART Revision 5 is the default HART output. (2) For local addressing and configuration, M4 (LOI) is required. Not available with product certification codes E4, EM, EP, I6, IM, KD, KL, KM, KP, KS,
N3. (3) This option is only available with intrinsically safe approvals. (4) Only available with C6, E2, E5, I5, K5, KB, EM , EP, and E8 product certifications.

62

Emerson.com/Rosemount

April 2021

Rosemount 3051

Process connection size, material, extension length (high side)

Code G0(1) H0(1) J0 A0(1) A2(1) A4(1) A6(1) B0(1) B2(1) B4(1) B6(1) C0(1) C2(1) C4(1) C6(1) D0(1) D2(1) D4(1) D6(1) E0 F0

Process connection size 2-in./DN 50/A 2-in./DN 50 2-in./DN 50 3-in./DN 80 3-in./DN 80 3-in./DN 80 3-in./DN 80 4-in./DN 100 4-in./DN 100 4-in./DN 100 4-in./DN 100 3-in./DN 80 3-in./DN 80 3-in./DN 80 3-in./DN 80 4-in./DN 100 4-in./DN 100 4-in./DN 100 4-in./DN 100 3-in./DN 80 4-in./DN 100

Material 316L SST Alloy C-276 Tantalum 316L SST 316L SST 316L SST 316L SST 316L SST 316L SST 316L SST 316L SST Alloy C-276 Alloy C-276 Alloy C-276 Alloy C-276 Alloy C-276 Alloy C-276 Alloy C-276 Alloy C-276 Tantalum Tantalum

Extension length

Flush mount only



Flush mount only



Flush mount only



Flush mount



2-in./50 mm



4-in./100 mm



6-in./150 mm



Flush mount



2-in./50 mm



4-in./100 mm



6-in./150 mm



Flush mount



2-in./50 mm



4-in./100 mm



6-in./150 mm



Flush mount



2-in./50 mm



4-in./100 mm



6-in./150 mm



Flush mount only



Flush mount only



(1) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

Emerson.com/Rosemount

63

Rosemount 3051

April 2021

Mounting flange size, rating, material (high side)

Code M A B N C D P E X(1) F(1) G(1) Y(1) H(1) J(1) Z(1) L(1) Q R S V K(1) T(1) U(1) W(1) 7(1) 1 2 3 4(1) 5(1) 6(1)

Size 2-in. 3-in. 4-in. 2-in. 3.in. 4-in. 2-in. 3-in. 2-in. 3-in. 4-in. 2-in. 3-in. 4-in. 2-in. 3-in. DN 50 DN 80 DN 100 DN 100 DN 50 DN 80 DN 100 DN 100 4-in. N/A N/A N/A N/A N/A N/A

Rating

Material

ASME B16.5 Class 150

CS



CS



CS



ASME B16.5 Class 300

CS



CS



CS



ASME B16.5 Class 600

CS



CS



ASME B16.5 Class 150

316 SST



316 SST



316 SST



ASME B16.5 Class 300

316 SST



316 SST



316 SST



ASME B16.5 Class 600

316 SST



316 SST



PN 10-40 per EN 1092-1

CS



PN 40 per EN 1092-1

CS



CS



PN 10/16 per EN 1092-1

CS



PN 10-40 per EN 1092-1

316 SST



PN 40 per EN 1092-1

316 SST



316 SST



PN 10/16 per EN 1092-1

316 SST



ASME B16.5 Class 600

316 SST



10K per JIS B2238

316 SST

20K per JIS B2238

CS

40K per JIS B2238

CS

10K per JIS B2238

CS

20K per JIS B2238

316 SST

40K per JIS B2238

316 SST

(1) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

64

Emerson.com/Rosemount

April 2021

Rosemount 3051

Seal fill fluid
Code Description

D

Silicone 200

F

Silicone 200 for vacuum

applications

Specific gravity
0.93
0.93

L

Dow Corning® 704 diffusion 1.07

pump fluid

C

D.C. Silicone 704 for vacuum 1.07

applications

A

SYLTHERMTM XLT

0.85

H

Inert (halocarbon)

1.85

G

Glycerin and water

1.13

N

Neobee® M-20

0.92

P

Propylene glycol and water

1.02

Temperature limits (ambient temperature of 70° F [21° C])

­49 to 401 °F (­45 to 205 °C)



For use in vacuum applications below 14.7 psia (1 bar-a), refer to  vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.

32 to 401 °F (0 to 205 °C)



For use in vacuum applications below 14.7 psia (1 bar-a), refer to  vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.

­102 to 293 °F (­75 to 145 °C)



­49 to 320 °F (­45 to 160 °C)



5 to 203 °F (­15 to 95 °C)



5 to 401 °F (­15 to 205 °C)



5 to 203 °F (­15 to 95 °C)



Low pressure side

Code Configuration

11(1) Gage

21

Differential

22(1) Differential

2A(2) Differential

2B(1)(2) Differential

31(1)

Tuned-system assembly with remote seal

Flange adapter
SST SST SST SST SST None

Diaphragm material 316L SST 316 SST
Alloy C-276 316 SST
Alloy C-276 316 SST

Sensor fluid

Silicone



Silicone



Silicone



Inert (halocarbon)



Inert (halocarbon)



Silicone (requires option code S1) 

(1) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(2) Not available with wireless output code X.

O-ring

Code Description

A

Glass-filled PTFE



Housing material

Code A B

Material Aluminum Aluminum

Conduit entry size

½­14 NPT



M20 x 1.5



Emerson.com/Rosemount

65

Rosemount 3051

April 2021

Code Material

Conduit entry size

E

Aluminum, ultra low copper

½­14 NPT

F

Aluminum, ultra low copper

M20 x 1.5

J

SST

½­14 NPT



K

SST

M20 x 1.5



P(1)

Engineered polymer

No conduit entries



D(2)

Aluminum

G½

M(2)

SST

G½

(1) Only available with wireless output code X. (2) Transmitter conduit entry will be ½ NPT and a ½ NPT to G½ thread adapter will be provided. Only available with product certifications options I1,
I2, I3, I7, IA, IB, IM, KA, N1, N3, N7. Housing code D is also available with E4, and IG

Wireless options
Requires wireless output code X and Engineered Polymer Housing code P.

Wireless transmit rate, operating frequency, and protocol

Code Description

WA3 User configurable transmit rate, 2.4 GHz WirelessHART



Antenna and SmartPower

Code Description

WP5 Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)



Addtional options
Include with selected model number.

Extended product warranty

Code Description

WR3 3-year limited warranty



WR5 5-year limited warranty



PlantwebTM control functionality

Code Description

A01

FOUNDATIONTM Fieldbus control function block suite



66

Emerson.com/Rosemount

April 2021

Rosemount 3051

PlantwebTM diagnostic functionality

Code Description

DA0 Loop Integrity HART® Diagnostic



D01

FOUNDATIONTM Fieldbus Diagnostics Suite



Seal assemblies
"Assemble-to" items are specified separately and require a completed model number.

Code Description

S1

Assembled to one Rosemount 1199 Seal



Remote seal diaphragm coating

Code Description

SZ

0.0002-in. (5 µm) gold-plated diaphragm

FP(1) CorrosionShield PFA coated diaphragm

(1) Not compatible with spiral wound gasket.

Product certifications

Code Description

E8

ATEX Flameproof and Dust Certification



I1(1)

ATEX Intrinsic Safety and Dust



IA

ATEX FISCO Intrinsic Safety; for FOUNDATIONTM Fieldbus or PROFIBUS® PA Protocol only



N1

ATEX Type n Certification and Dust



K8

ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)



E4

TIIS Flame-proof



I4

TIIS Intrinsic Safety



E5

USA Explosion-proof, Dust Ignition-Proof



I5(2)

USA Intrinsically Safe, Nonincendive



C6

Canada Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2



E6

Canada Explosion-proof, Dust Ignition-proof, Division 2



I6

Canada Intrinsic Safety



K6

Canada and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)



E7

IECEx Flameproof, Dust Ignition-proof



I7

IECEx Intrinsic Safety



N7

IECEx Type n Certification



K7

IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)



IG

IECEx FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



Emerson.com/Rosemount

67

Rosemount 3051

April 2021

K5

USA Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2



E2

INMETRO Flameproof001



I2

INMETRO Intrinsic Safety



IB

INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only



K2

INMETRO Flameproof, Intrinsic Safety



E3

China Flameproof



I3

China Intrinsic Safety



N3

China Type n



EM

Technical Regulations Customs Union (EAC) Flameproof



IM

Technical Regulations Customs Union (EAC) Intrinsic Safety



KM

Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety



KB

USA and Canada Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) 

KD

USA, Canada, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)



KL(3) USA, Canada, IECEx, ATEX Intrinsic Safety Combination



KS

USA, Canada, IECEx, ATEX Explosion Proof, Intrinsically Safe, Dust, Non-Incendive, Type-N, Div. 2



EP

Republic of Korea Flameproof



IP

Republic of Korea Intrinsic Safety



KP

Republic of Korea Flameproof, Intrinsic Safety



(1) Dust approval not applicable to output code X. (2) Nonincendive certification not provided with output code (X). (3) Only available with output code X.

Shipboard approvals
Shipyard approvals are not available with wireless output (code X).

Code Description

SBS

American Bureau of Shipping



SBV(1) Bureau Veritas (BV)



SDN Det Norske Veritas



SLL(1) Lloyds Register (LR)



(1) Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7

SST tagging

Code Y2

Description 316 SST nameplate, top tag, wire-on tag, and fasteners

68

Emerson.com/Rosemount

April 2021

Bolting material

Code L4

Description Austenitic 316 SST bolts

Display and interface options

Code M4(1) M5

Description LCD display with LOI LCD display

(1) Only available with 4-20 mA HART® output (code A) and PROFIBUS®-PA (code W).

Calibration certificate

Code Q4 QG(1) QP

Description Calibration certificate Calibration certificate and GOST verification certificate Calibration certification and tamper evident seal

(1) Contact an Emerson representative for availability.

Material traceability certification

Code Q8

Description Material traceability certification per EN 10204 3.1

Positive material identification (PMI)

Code Q76

Description PMI verification and certificate

Quality certification for safety
The quality certification for safety is only available with HART® 4­20 mA output (code A).

Code QT

Description Safety certified to IEC 61508 with certificate of FMEDA

Toolkit total system performance reports

Code QZ

Description Remote seal system performance calculation report

Conduit electrical connector
The conduit electrical connector option is not available with wireless output (code X).

Emerson.com/Rosemount

Rosemount 3051
  
  
 
 
69

Rosemount 3051

April 2021

Code Description

GE

M12, 4-pin, male connector (eurofast®)



GM

A size mini, 4-pin, male connector (minifast®)



Configuration buttons

Code Description

D4(1) Analog zero and span



DZ(2) Digital zero trim



(1) Only available with HART® 4­20 mA output (code A). (2) Only available with HART 4­20 mA output (output code A) and wireless output (output code X)

Transient protection
The transient protection option is not available with wireless output (code X). The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IB, and IE.

Code Description

T1

Transient protection terminal block



Software configuration
The software configuration option is only available with HART® 4­20 mA output (output code A) and wireless output (output code X).

Code Description

C1

Custom software configuration (For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see 

the Rosemount 3051 Wireless Configuration Data Sheet.)

Low power output

Code Description

C2

0.8­3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)



Alarm levels
The alarm levels option is only available with HART 4­20 mA output (code A).

Code C4(1) CN(1) CR CS CT

Description

Analog output levels compliant with NAMUR recommendation NE 43, alarm high



Analog output levels compliant with NAMUR recommendation NE 43, alarm low



Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet) 

Rosemount standard low alarm



(1) NAMUR-compliant operation is preset at the factory and can be changed to standard operation in the field for the standard Rosemount 3051.

70

Emerson.com/Rosemount

April 2021

Rosemount 3051

Conduit plug
The conduit plug option is not available with wireless output (code X).

Code Description

DO

316 SST conduit plug



Ground screw
The ground screw option is not available with wireless output (code X). The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.

Code Description

V5

External ground screw assembly



Lower housing flushing connection options

Code F1 F2 F3 F4 F7 F8 F9 F0

Ring material 316 SST 316 SST Alloy C-276 Alloy C-276 316 SST 316 SST Alloy C-276 Alloy C-276

Number 1 2 1 2 1 2 1 2

Size (NPT)

¼­18 NPT



¼­18 NPT



¼­18 NPT



¼­18 NPT



½­14 NPT



½­14 NPT



½­14 NPT



½­14 NPT



Lower housing intermediate gasket material

Code Description

S0

No gasket for lower housing



SY(1) Thermo-Tork® TN-9000



(1) Gasket provided when lower housing is ordered.

NACE certificate
Note that NACE®-compliant wetted materials are required. Materials of construction must comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult the latest standard for details. All selected materials must also conform to NACE MR0103 for sour refining environments.

Code Description

Q15 Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials



Q25 Certificate of Compliance to NACE MR0103 for wetted materials



HART revision configuration (requires HART Protocol output code A)
HART® Revision 5 is the default HART output.

Emerson.com/Rosemount

71

Rosemount 3051

Code HR5 HR7

Description Configured for HART Revision 5 Configured for HART Revision 7

Wireless power accessory
This option is only available with output code X.

Code HS

Description Hot swap power adapter for power module replacement

April 2021
 

72

Emerson.com/Rosemount

April 2021

Rosemount 3051

Specifications

Performance specifications
This product data sheet covers HART®, WirelessHART®, FOUNDATIONTM Fieldbus, and PROFIBUS® PA Protocols unless specified otherwise.
For zero-based spans, reference conditions, silicone oil fill, glass-filled PTFE O-rings, SST materials, coplanar flange, or ½­14 NPT process connections, digital trim values set to equal range points.

Conformance to specifications (±3 [Sigma])
Technology leadership, advanced manufacturing techniques, and statistical process control ensure specification conformance to at least ±3.

Reference accuracy
Stated reference accuracy equations include terminal based linearity, hysteresis, and repeatability. For wireless, FOUNDATIONTM Fieldbus, and PROFIBUS® PA devices, use calibrated range in place of span.

Models

Rosemount 3051 and WirelessHART®

Rosemount 3051C(1)

Range 5

±0.065% of span For spans less than 10:1, accuracy =

Ranges 2­4

± 0.04% of span For spans less than 10:1(2), accuracy =

Range 1

± 0.10% of span For spans less than 15:1, accuracy =

Range 0 (CD)

± 0.10% of span For spans less than 2:1, accuracy = ± 0.05% of URL

Rosemount 3051CA

Ranges 1­4

± 0.04% of span(3) For spans less 10:1, accuracy =

Emerson.com/Rosemount

73

Rosemount 3051

Rosemount 3051T(1)

Range 0

± 0.04% of span(3) For spans less 5:1 to 20:1, accuracy =

Ranges 1­4

± 0.04% of span(3) For spans less than 10:1, accuracy =

April 2021

Range 5­6

± 0.075% of span

Rosemount 3051L

Ranges 2-4

± 0.075% of span For spans less than 10:1, accuracy =

(1) For Rosemount 3051C and 3051T with 1199 assemble to code S1, use 3051L specification. (2) For output code F, for span less than 5:1. (3) For output code M, ±0.065 percent span.

Flow Performance - Flow Reference Accuracy
Note Accuracy over range of use is always application dependent. Range 1 flow meters may experience an additional uncertainty up to 0.9 percent. Consult your Emerson representative for exact specifications.

Rosemount 3051CFA AnnubarTM Flow Meter

Ranges 2­3

±1.80% of flow rate at 8:1 flow turndown

Rosemount 3051CFC_A Compact Annubar Flow Meter ­ Rosemount Annubar Option A

Ranges 2­3

Standard

±2.10% of flow rate at 8:1 flow turndown

Calibrated

±1.80% of Flow Rate at 8:1 flow turndown

Rosemount 3051CFC_C Compact Orifice Flow Meter ­ Conditioning Option C

Ranges 2­3

 = 0.4

±1.75% of flow rate at 8:1 flow turndown

 = 0.50, 0.65 ±1.95% of flow rate at 8:1 flow turndown

Rosemount 3051CFC_P Compact Orifice Flow Meter ­ Orifice Type Option P(1)

Ranges 2­3

= 0.4

±2.00% of flow rate at 8:1 flow turndown

= 0.65

±2.00% of flow rate at 8:1 flow turndown

Rosemount 3051CFP Integral Orifice Flow Meter

Ranges 2­3

<0.1

±3.00% of flow rate at 8:1 flow turndown

74

Emerson.com/Rosemount

April 2021

Rosemount 3051

0.1< <0.2 0.2< <0.6 0.6< <0.8

±1.95% of flow rate at 8:1 flow turndown ±1.75% of flow rate at 8:1 flow turndown ±2.15% of flow rate at 8:1 flow turndown

(1) Applicable to 2- to 12-in. line sizes. For smaller line sizes, see the Rosemount DP Flow Meters and Primary Elements Product Data Sheet.

Total performance
Total performance is based on combined errors of reference accuracy, ambient temperature effect, and static pressure effect at normal operating conditions (70 percent of span typical reading, 740 psi (51,02 bar) line pressure).
For ±50 °F (28 °C) temperature changes; 0­100 percent relative humidity, from 1:1 to 5:1 rangedown

Models
Rosemount 3051C Ranges 2­5

Total performance(1) ± 0.14% of span

Rosemount 3051L Ranges 2­4

Use Instrument Toolkit or the QZ option to quantify the total performance of a remote seal assembly under operating conditions.

(1) For output code W, F, and M, total performance is ±0.15 percent of span.

Long term stability
Models Rosemount 3051C Ranges 2­5
Rosemount 3051 CD, 3051CG Low/Draft Range Ranges 0-1, 3051TG Range 0 Rosemount 3051CA Low Range Range 1
Rosemount 3051T Ranges 1­4
Rosemount 3051L Ranges 2­3 Ranges 4­5

Long term stability
±0.2% of URL for 10 years ±50 °F (28 °C) temperature changes, and up to 1000 psi (68.95 bar) line pressure. ±0.2% of URL for 1 year
±0.2% of URL for 10 years ±50 °F (28 °C) temperature changes, and up to 1000 psi (68.95 bar) line pressure.
±0.2% of URL for 10 years ±50 °F (28 °C) temperature changes, and up to 1000 psi (68.95 bar) line pressure.
±0.1% of URL for 1 year ±0.2% of URL for 1 year

Dynamic performance
4 - 20 mA HART®(1)
Total Response Time (T d + T c)(3): Rosemount 3051C

FOUNDATIONTM Fieldbus and PROFIBUS® PA Protocols(2)

Typical HART transmitter response time

Emerson.com/Rosemount

75

Rosemount 3051

April 2021

Ranges 2-5 Range 1 Range 0 Rosemount 3051T Rosemount 3051L Dead time (Td) Update rate(4)

4 - 20 mA HART®(1)
100 ms 255 ms 700 ms 100 ms See Instrument Toolkit. 45 ms (nominal) 22 times per second

FOUNDATIONTM Fieldbus and PROFIBUS® PA Protocols(2) 152 ms 307 ms N/A 152 ms See Instrument Toolkit. 97 ms 22 times per second

Typical HART transmitter response time

(1) Dead time and update rate apply to all models and ranges; analog output only. (2) Transducer block response time, Analog Input block execution time not included. (3) Nominal total response time at 75 °F (24 °C) reference conditions. (4) Does not apply to wireless (output code X). See Wireless (output code X) for wireless update rate.

Line pressure effect per 1000 psi (68.95 bar)
For line pressures above 2000 psi (137.90 bar) and Ranges 4­5, see the following documents. For HART®, see the Rosemount 3051 Reference Manual. For WirelessHART®, see the Rosemount 3051 Wireless Reference Manual.
For FOUNDATIONTM Fieldbus, see the Rosemount 3051 Reference Manual. For PROFIBUS® PA, see the Rosemount 3051 Reference Manual.
Table 1: Rosemount 3051CD and 3051CF Line Pressure Effect

Range

Line pressure effect

Zero error

Ranges 2­3

±0.05% of URL/1000 psi (68,95 bar) for line pressures from 0 to 2000 psi (0 to 137.90 bar)

Range 1

±0.25% of URL/1000 psi (68,95 bar) for line pressures from 0 to 2000 psi (0 to 137.90 bar)

Range 0

±0.125% of URL/100 psi (6,89 bar) for line pressures from 0 to 750 psi (0 to 51.71 bar)

Span error

Ranges 2­3

±0.1% of reading/1000 psi (68.95 bar)

Range 1

±0.4% of reading/1000 psi (68.95 bar)

Range 0

±0.15% of reading/100 psi (6.895 bar)

Ambient temperature effect per 50 °F (28 °C)

Models Rosemount 3051C Ranges 2­5
Range 1 Range 0

Ambient temperature effect
±(0.0125% URL + 0.0625% span) from 1:1 to 5:1 ±(0.025% URL + 0.125% span) from 5:1 to 150:1 ±(0.1% URL + 0.25% span) from 1:1 to 30:1 ±(0.14% URL + 0.15% span) from 30:1 to 50:1 ±(0.25% URL + 0.05% span) from 1:1 to 30:1

76

Emerson.com/Rosemount

April 2021

Rosemount 3051

Models Rosemount 3051CA Ranges 1­4
Rosemount 3051T Range 2­4
Range 1
Range 0 Range 5­6 Rosemount 3051L

Ambient temperature effect
±(0.025% URL + 0.125% span) from 1:1 to 30:1 ±(0.035% URL + 0.125% span) from 30:1 to 150:1
±(0.025% URL + 0.125% span) from 1:1 to 30:1 ±(0.035% URL + 0.125% span) from 30:1 to 150:1 ±(0.025% URL + 0.125% span) from 1:1 to 10:1 ±(0.05% URL + 0.125% span) from 10:1 to 100:1 ±(0.15% URL + 0.075% span) from 1:1 to 20:1 ±(0.1% URL + 0.15% span) from 1:1 to 5:1 See Instrument ToolkitTM software.

Mounting position effects

Models Rosemount 3051C Rosemount 3051CA, 3051T Rosemount 3051L

Mounting position effects Zero shifts up to ±1.25 in H2O (3.11 mbar), which can be calibrated out. No span effect. Zero shifts up to ±2.5 in H2O (6.22 mbar), which can be calibrated out. No span effect. With liquid level diaphragm in vertical plane, zero shift of up to ±1 in H2O (2.49 mbar). With diaphragm in horizontal plane, zero shift of up to ±5 in H2O (12.43 mbar) plus extension length on extended units. All zero shifts can be calibrated out. No span effect.

Vibration effect
Less than ±0.1 percent of URL when tested per the requirements of IEC60770-1: 1999 field or pipeline with high vibration level (10­ 60 Hz 0.21 mm displacement peak amplitude/60­2000 Hz 3g).
Power supply effect
Less than ±0.005 percent of calibrated span per volt change.
Electromagnetic compatibility
Meets all industrial environment requirements of EN61326 and NAMUR NE-21. Maximum deviation <1 percent Span during EMC disturbance. Note NAMUR NE-21 does not apply to Low-Power (Transmitter output option code M) or Wireless (Transmitter output code X).
Note During surge event, device with 4-20 mA (Transmitter output option code A) may exceed maximum EMC deviation limit or reset; however, device will self-recover and return to normal operation within specified start-up time.

Transient protection (option code T1)
Tested in accordance with IEEE C62.41.2-2002, location category B  6 kV crest (0.5 µs - 100 kHz)  3 kA crest (8 x 20 µs)

Emerson.com/Rosemount

77

Rosemount 3051
 6 kV crest (1.2 x 50 µs)

April 2021

Functional specifications

Range and sensor limits
Table 2: Rosemount 3051CD, 3051CG, 3051CF, and 3051L Range and Sensor Limits

Range(1) Minimum span Range and sensor limits

Rosemount

Upper (URL)

3051CD, 3051CG, 3051CF, 3051L(2)

Lower (LRL)
Rosemount 3051CD Differential, 3051CF Flow Meters

Rosemount 3051CG Gage(3)

Rosemount 3051L Differential

Rosemount 3051L Gage(3)

0

0.10 inH2O

3.00 inH2O ­3.00 inH2O

N/A

N/A

N/A

(0.24 mbar)

(7.45 mbar) (­7.45 mbar)

1

0.50 inH2O

25.00 inH2O ­25.00 inH2O

­25.00 inH2O

N/A

N/A

(1.24 mbar)

(62.16 mbar) (­62.16 mbar)

(­62.16 mbar)

2

1.67 inH2O

250.00 inH2O ­250.00 inH2O

­250.00 inH2O

­250.00 inH2O

­250.00 inH2O

(4.15 mbar)

(621.60 mbar) (­621.60 mbar) (­621.60 mbar) (­621.60 mbar) (­621.60 mbar)

3

6.67 inH2O

1000.00

­1000.00 inH2O 0.50 psia

­1000.00 inH2O 0.50 psia

(16.58 mbar)

inH2O

(­2.48 bar)

(34.47 mbar)

(­2.48 bar)

(34.47 mbar)

(2.48 bar)

4

2.00 psi

300.00 psi

­300.00 psi

0.50 psia

­300.00 psi

0.50 psia

(137.89 mbar)

(20.68 bar) (­20.68 bar)

(34.47 mbar)

(­20.68 bar)

(34.47 mbar)

5

13.33 psi

2000.00 psi ­ 2000.00 psi

0.50 psia

N/A

N/A

(919.01 mbar)

(137.89 bar) (­137.89 bar)

(34.47 mbar)

(1) Range 0 only available with Rosemount 3051CD. Range 1 only available with 3051CD, 3051CG, or 3051CF. inH2O referenced at 68 °F (20 °C). (2) For outputs options W and M, minimum span are: range 1 - 0.50 inH2O (1.24 mbar), range 2 - 2.50 inH2O (6.21 mbar), range 3 - 10.00 inH2O
(24.86 mbar), range 4 - 3.00 psi (0.21 bar), range 5 - 20.00 psi (1.38 bar). (3) Assumes atmospheric pressure of 14.7 psig.

Table 3: Rosemount 3051CA and 3051T Range and Sensor Limits

Range

Rosemount 3051CA

Minimum span(1)

Range and sensor limits

Rosemount 3051T

Minimum span(1)

Range and sensor limits

Lower(2) (LRL) (gage)

Upper (URL)

0

N/A

N/A

Lower (LRL) Upper (URL)

N/A

0.25 psi

(17.24 mbar)

5 psi (344.74 mbar)

Lower (LRL) (absolute)
N/A

­5 psi (­344.74 mbar)

1

0.30 psi (20.68 30 psia

0 psia

0.30 psi

30.00 psi

0 psia (0 bar) ­14.70 psig

mbar)

(2.06 bar)

(0 bar)

(20.68 mbar) (2.06 bar)

(­1.01 bar)

2

1.00 psi (68.94 150 psia (10.34 0 psia

1.00 psi

150.00 psi

0 psia (0 bar) ­14.70 psig

mbar)

bar)

(0 bar)

(68.94 mbar) (10.34 bar)

(­1.01 bar)

3

5.33 psi

800 psia (55.15 0 psia

5.33 psi

800.00 psi

0 psia (0 bar) ­14.70 psig

(367.49 mbar) bar)

(0 bar)

(367.49 mbar) (55.15 bar)

(­1.01 bar)

78

Emerson.com/Rosemount

April 2021

Rosemount 3051

Table 3: Rosemount 3051CA and 3051T Range and Sensor Limits (continued)

Range

Rosemount 3051CA

Minimum span(1)

Range and sensor limits

Rosemount 3051T

Minimum span(1)

Range and sensor limits

Lower(2) (LRL) (gage)

Upper (URL)

Lower (LRL) Upper (URL)

Lower (LRL) (absolute)

4

26.67 psi (1.83 4000 psia

0 psia

26.67 psi

4000.00 psi

0 psia (0 bar) ­14.70 psig

bar)

(275.79 bar) (0 bar)

(1.83 bar)

(275.79 bar)

(­1.01 bar)

5

N/A

N/A

N/A

2000 psi

10000.00 psi 0 psia (0 bar) ­14.70 psig

(137.86 bar) (689.47 bar)

(­1.01 bar)

6

N/A

N/A

N/A

4000 psi

20000.00 psi 0 psia

­14.70 psig

(275.79 bar) (1378.95 bar) (0 bar)

(­1.01 bar)

(1) For output options W and M, minimum span are: range 2 ­ 1.50 psi (0.10 bar), range 3 ­ 8.00 psi (0.55 bar), range 4 ­ 40.00 psi (2.75 bar), range 5 for 3051T ­ 2000.00 psi (137.89 bar).
(2) Assumes atmospheric pressure of 14.7 psig.

Service Liquid, gas, and vapor applications.

4­20 mA HART® (output code A)
Power supply External power supply required. Standard transmitter (4­20 mA) operates on 10.5­42.4 Vdc with no load.
Load limitations Maximum loop resistance is determined by the voltage level of the external power supply described by: Max. loop resistance = 43.5 (power supply voltage - 10.5) Communication requires a minimum loop resistance of 250 ohms.
1387

1000

A

500

B

0

10.5 20 30
C
A. Load (s) B. Operating region C. Voltage (Vdc)

42.4

Note For CSA approval, power supply must not exceed 42.4 V.

Emerson.com/Rosemount

79

Rosemount 3051

April 2021

Indication Optional 2-line LCD/LOI Display
Optional configuration buttons Configuration buttons need to be specified:  Digital Zero trim (option code DZ) changes digital value of the transmitter and is used for performing a sensor zero trim.  Analog Zero Span (option code D4) changes analog value and can be used to rerange the transmitter with an applied pressure.

Output
Two-wire 4­20 mA, user selectable for linear or square root output. Digital process variable superimposed on 4­20 mA signal, available to any host that conforms to HARTTM Protocol. The Rosemount 3051 Transmitter comes with Selectable HART Revisions. Digital communications based on HART Revision 5 (default) or Revision 7 (option code HR7) protocol can be selected. The HART revision can be switched in the field using any HART based configuration tool or the optional LOI (M4).
Loop Integrity diagnostics
The Loop Integrity diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitter 4-20 mA output signal. The diagnostics can detect loop problems such as water in the terminal compartment, corrosion of terminals, improper grounding, and unstable power supplies.
The device dashboard presents the diagnostics in a graphical, task-based interface that provides single-click access to critical process/device information and descriptive graphical troubleshooting.
LOI
The LOI uses a two button menu with internal and external configuration buttons. Internal buttons are always configured for LOI. External buttons can be configured for either LOI (option code M4), analog zero and span (option code D4), or digital zero trim (option code DZ). See Rosemount 3051 Reference Manual for LOI configuration menu.

FOUNDATIONTM Fieldbus (output code F)

Power supply
External power supply required; transmitters operate on 9.0 to 32.0 Vdc transmitter terminal voltage. FISCO transmitters operate on 9.0 to 17.5 Vdc.

Current draw 17.5 mA for all configurations (including LCD display option)

Indication Optional two-line LCD display

FOUNDATION Fieldbus block execution times

Block Resource Sensor and SPM transducer LCD display Analog input 1, 2 PID Input selector Arithmetic

Execution time N/A N/A N/A 20 milliseconds 25 milliseconds 20 milliseconds 20 milliseconds

80

Emerson.com/Rosemount

April 2021

Rosemount 3051

Block Signal characterizer Integrator Output splitter Control selector

Execution time 20 milliseconds 20 milliseconds 20 milliseconds 20 milliseconds

FOUNDATION Fieldbus parameters Links: Virtual communications relationship (VCR):

25 (max.) 20 (max.)

FOUNDATION Fieldbus function blocks (option A01)

Resource block

The resource block contains diagnostic, hardware, and electronics information. There are no linkable inputs or outputs to the resource block.

Sensor transducer The sensor transducer block contains sensor information and the ability to calibrate the pressure sensor or

block

recall factory calibration.

LCD transducer block

The LCD display transducer block is used to configure the LCD display meter.

Analog input block The analog input (AI) function block processes the measurements from the sensor and makes them available to other function blocks. The output value from the AI block is in engineering units and contains a status indicating the quality of the measurement. The AI block is widely used for scaling functionality.

Input selector block The input selector (ISEL) function block can be used to select the first good, hot backup, maximum, minimum, or average of as many as eight input values and place it at the output. The block supports signal status propagation.

Integrator block

The integrator (INT) function block integrates one or two variables over time. The block compares the integrated or accumulated value to pre-trip and trip limits and generates discrete output signals when the limits are reached. The INT function block is used as a totalizer. This block will accept up to two inputs, has six options how to totalize the inputs, and two trip outputs.

Arithmetic block

The arithmetic (ARTH) function block provides the ability to configure a range extension function for a primary input. It can also be used to compute nine different arithmetic functions including flow with partial density compensation, electronic remote seals, hydrostatic tank gaging, ratio control, and others.

Signal characterizer The signal characterizer (SGCR) function block characterizes or approximates any function that defines an

block

input/output relationship. The function is defined by configuring as many as 20 X,Y coordinates. The block

interpolates an output value for a given input value using the curve defined by the configured coordinates.

Two separate analog input signals can be processed simultaneously to give two corresponding separate

output values using the same defined curve.

PID block

The PID function block combines all of the necessary logic to perform proportional/integral/derivative (PID) control. The block supports mode control, signal scaling and limiting, feed forward control, override tracking, alarm limit detection, and signal status propagation.

Control selector block

The control selector function block selects one of two or three inputs to be the output. The inputs are normally connected to the outputs of PID or other function blocks. One of the inputs would be considered normal and the other two overrides.

Output splitter block

The output splitter function block provides the capability to drive two control outputs from a single input. It takes the output of one PID or other control block to control two valves or other actuators.

Backup Link Active Scheduler (LAS) The transmitter can function as a Link Active Scheduler if the current link master device fails or is removed from the segment.

Emerson.com/Rosemount

81

Rosemount 3051

April 2021

FOUNDATION Fieldbus Diagnostics Suite (option code D01)
The Rosemount 3051C FOUNDATION Fieldbus Diagnostics Suite features SPM technology to detect changes in the process, process equipment, or installation conditions (such as plugged impulse lines) of the transmitter. This is done by modeling the process noise signature (using the statistical values of mean and standard deviation) under normal conditions and then comparing the baseline values to current values over time. If a significant change in the current values is detected, the transmitter can generate an alert.

PROFIBUS® PA (output code W)

Profile version 3.02

Power supply
External power supply required; transmitters operate on 9.0 to 32.0 Vdc transmitter terminal voltage. FISCO transmitters operate on 9.0 to 17.5 Vdc.

Current draw 17.5 mA for all configurations (including LCD display option)

Output update rate Four times per second

Standard function block

Analog input (AI block)

The AI function block processes the measurements and makes them available to the host device. The output value from the AI block is in engineering units and contains a status indicating the quality of the measurement. The AI block is widely used for scaling functionality.

Note The channel, Set XD_Scale, Set L_Type, and sometimes Set Out_Scale are typically configured by instrument personnel. Other AI block parameters, block links, and schedule are typically configured by the control systems configuration engineer.

Indication Optional two-line LCD display
LOI The LOI uses a two-button menu with external configuration buttons.

Wireless (output code X)
Output IEC 62591 (WirelessHART), 2.4 GHz DSSS
Wireless radio (internal antenna, WP5 option)  Frequency: 2.400 ­ 2.485 GHz  Channels: 15  Modulation: IEEE 802.15.4 compliant DSSS  Transmission: Maximum of 10 dBm EIRP
Local display The optional three-line, seven-digit LCD display can display user-selectable information, such as primary variable in engineering units, scaled variable, percent of range, sensor module temperature, and electronics temperature. The display updates based on the wireless update rate.

82

Emerson.com/Rosemount

April 2021

Rosemount 3051

Digital zero trim Digital zero trim (option DZ) is an offset adjustment to compensate for mounting position effects, up to 5 percent of URL.
Update rate User selectable 1 second to 60 minute.
Wireless sensor module for in-line transmitters The Rosemount 3051 Wireless Transmitter requires the engineered polymer housing to be selected. The standard sensor module will come with aluminum material. If SST is required, you must select the option WSM.
Power module Field replaceable, keyed connection eliminates the risk of incorrect installation, Intrinsically Safe Lithium-thionyl chloride Power Module with PBT/PC enclosure. Ten-year life at one minute update rate. (1) Note Continuous exposure to ambient temperature limits of -40 °F or 185 °F (­40 °C or 85 °C) may reduce specified life by less than 20 percent.
Low power output
1­5 Vdc HART low power (output code M)
Output The default three-wire 1­5 Vdc is a user-selectable output. Also user selectable for linear or square root output configuration. Digital process variable superimposed on voltage signal, available to any host conforming to the HART Protocol. Low-power transmitter operates on 6­12 Vdc with no load. Option code C2 changes the output from 1­5 Vdc to 0.8­3.2 Vdc.
Power consumption 3.0 mA, 18­36 mW
Minimum load impedance 100 k (Vout wiring) Indication Optional five-digit LCD display
Overpressure limits
Rosemount 3051CD/CG/CF  Range 0: 750 psi (51.71 bar)  Range 1: 2000 psig (137.90 bar)  Ranges 2­5: 3626 psig (250.00 bar), 4500 psig (310.26 bar) for option code P9
Rosemount 3051CA  Range 1: 750 psia (51.71 bar)  Range 2: 1500 psia (103.42 bar)  Range 3: 1600 psia (110.32 bar)

(1) Reference conditions are 70 °F (21 °C), and routing data for three additional network devices.

Emerson.com/Rosemount

83

Rosemount 3051

April 2021

 Range 4: 6000 psia (413.69 bar)

Rosemount 3051TG/TA  Range 0: 60 psi (4.14 bar)  Range 1: 750 psi (51.71 bar)  Range 2: 1500 psi (103.42 bar)  Range 3: 1600 psi (110.32 bar)  Range 4: 6000 psi (413.69 bar)  Range 5: 15000 psi (1034.21 bar)  Range 6: 24000 psi (1654.74 bar)
For Rosemount 3051L or level flange option codes FA, FB, FC, FD, FP, and FQ, limit is 0 psia to the flange rating or sensor rating, whichever is lower.
Table 4: Rosemount 3051L and Level Flange Rating Limits

Standard

Type

CS rating

SST rating

ANSI/ASME

Class 150

285 psig

275 psig

ANSI/ASME

Class 300

740 psig

720 psig

ANSI/ASME

Class 600

1480 psig

1440 psig

At 100 °F (38 °C), the rating decreases with increasing temperature, per ANSI/ASME B16.5.

DIN

PN 10­40

40 bar

40 bar

DIN

PN 10/16

16 bar

16 bar

DIN

PN 25/40

40 bar

40 bar

At 248 °F (120 °C), the rating decreases with increasing temperature, per DIN 2401.

Static pressure limit Rosemount 3051CD only
Operates within specifications between static line pressures of 0.5 psia and 3626 psig (4500 psig (310.26 bar) for option code P9). Range 0: 0.5 psia and 750 psig (0.03 bar and 51.71 bar) Range 1: 0.5 psia and 2000 psig (0.03 bar and 137.90 bar)
Burst pressure limits Rosemount 3051C, 3051CF coplanar or traditional transmitter flange
10081 psig (695,06 bar)
Rosemount 3051T in-line  Ranges 0­4: 11016 psi (759.53 bar)  Range 5: 26016 psig (1793.74 bar)  Range 6: 46092 psi (3177.93 bar)

84

Emerson.com/Rosemount

April 2021

Rosemount 3051

Failure mode alarm

HART® 4­20 mA (output option code A)
If self-diagnostics detect a sensor or microprocessor failure, the analog signal is driven either high or low to alert the user. High or low failure mode is user-selectable with a jumper/switch on the transmitter. The values to which the transmitter drives its output in failure mode depend on whether it is configured to standard, NAMUR-compliant, or custom levels (see alarm configuration below). The values for each are as follows:

Default NAMUR compliant (1) Custom levels (2)

High alarm  21.75 mA  22.5 mA 20.2 ­ 23.0 mA

Low alarm  3.75 mA  3.6 mA 3.4 ­ 3.8 mA

(1) Analog output levels are compliant with NAMUR recommendation NE 43; see option codes C4 or C5. (2) Low alarm must be 0.1 mA less than low saturation and high alarm must be 0.1 mA greater than high saturation.

Output code M
If self-diagnostics detect a gross transmitter failure, the analog signal will be driven either below 0.94 V or above 5.4 V to alert the user (below 0.75 V or above 4.4 V for Option C2). High or low alarm signal is user-selectable by internal jumper.

Output code F, W, and X
If self-diagnostics detect a gross transmitter failure, that information gets passed as an alert and a status along with the process variable.

Temperature limits

Ambient
 ­40 to 185 °F (­40 to 85 °C)  With LCD display(1)(2): ­40 to 176 °F (­40 to 80 °C)  With option code BR5: ­58 to 185 °F (­50 to 85 °C)  With option code BR6: ­76 to 185 °F (­60 to 85 °C)

(1) For the output code M and W, LCD display may not be readable, and LCD display updates will be slower at temperatures below ­22 °F (­30 °C). (2) Wireless LCD display may not be readable, and LCD display updates will be slower at temperature below ­4 °F (­20 °C).

Storage
Note If storage temperature is above 185 °F (85 °C), perform a sensor trim prior to installation.
 ­76 to 230 °F (­60 to 110 °C)  With LCD display: ­76 to 185 °F (­60 to 85 °C)  With wireless output: ­40 °F to 185 °F (­40 °C to 85 °C)

Process At atmospheric pressures and above. See Table 5. Table 5: Process Connection Temperature Limits
Rosemount 3051CD, 3051CG, 3051CF, 3051CA Silicone fill sensor(1) With coplanar flange

N/A ­40 to 250 °F (­40 to 121 °C)(2)

Emerson.com/Rosemount

85

Rosemount 3051

April 2021

Table 5: Process Connection Temperature Limits (continued)

With traditional flange With level flange With Rosemount 305 Integral Manifold Inert fill sensor(1)(4) With Option Code BR6, coplanar flange With Option Code BR6, traditional flange

­40 to 300 °F (­40 to 149 °C)(2)(3) ­40 to 300 °F (­40 to 149 °C)(2) ­40 to 300 °F (­40 to 149 °C)(2) ­40 to 185 °F (­40 to 85 °C) (5)(6) ­76 to 250 °F (­60 to 121 °C)(2) ­75 to 300 °F (­60 to 149 °C)(2)

Rosemount 3051T (process fill fluid) Silicone fill sensor(1) With Option Code BR6 Inert fill sensor(1)

­40 to 250 °F (­40 to 121 °C)(2) ­76 to 250 °F (­60 to 121 °C)(2) ­22 to 250 °F (­30 to 121 °C)(2)

Rosemount 3051L low-side temperature limits Silicone fill sensor(1) Inert fill sensor(1)

­40 to 250 °F (­40 to 121 °C)(2) ­40 to 185 °F (­40 to 85 °C)(5)

Rosemount 3051L high-side temperature limits (process fill fluid)

SYLTHERM XLT

­102 to 293 °F (­75 to 145 °C)

D.C. Silicone 704

32 to 401 °F (0 to 205 °C)

D.C. Silicone 200

­49 to 401 °F (­45 to 205 °C)

Inert Glycerin and water

­49 to 320 °F (­45 to 160 °C) 5 to 203 °F (­15 to 95 °C)

Neobee M-20

5 to 401 °F (­15 to 205 °C)

Propylene glycol and water

5 to 203 °F (­15 to 95 °C)

(1) Process temperatures above 185 °F (85 °C) require derating the ambient limits by a 1.5:1 ratio. (2) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures below 0.5 psia. (3) Rosemount 3051CD0 process temperature limits are ­40 to 212 °F (­40 to 100 °C). (4) Inert fill with traditional flange on Range 0: limits are 32 to 185 °F (0 to 85 °C). (5) 160 °F (71 °C) limit in vacuum service. (6) Not available for Rosemount 3051CA.

Humidity limits
0­100 percent relative humidity
Turn-on time
Performance within specifications less than 2.0 seconds (20.0 seconds for PROFIBUS® PA and FOUNDATIONTM Fieldbus Protocols) after power is applied to the transmitter. Note Does not apply to wireless option code X.

Volumetric displacement
Less than 0.005-in3 (0,08 cm3)

86

Emerson.com/Rosemount

April 2021

Rosemount 3051

Damping
4­20 mA HART® Analog output response to a step input change is user-enterable from 0.0 to 60 seconds for one time constant. This software damping is in addition to sensor module response time.
FOUNDATIONTM Fieldbus  Transducer block: User configurable  AI Block: User configurable
PROFIBUS® PA AI Block only: User configurable

Physical specifications
Material selection
Emerson provides a variety of Rosemount products with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser's sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product materials, options, and components for the particular application. Emerson is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product options, configuration, or materials of construction selected.
Electrical connections
½­14 NPT, G½, and M20 x 1.5 conduit. The polymer housing (code P) has no conduit entries. HART interface connections fixed to terminal block for output code A and to 701P Power Module for output code X.
Process connections
Rosemount 3051C  ¼­18 NPT on 2-in. centers  ½­14 NPT on 2-, 2-, or 2¼-in. centers
Rosemount 3051L  High pressure side: 2-, 3-, or 4-in., ASME B 16.5 (ANSI) Class 150, 300 or 600 flange; 50, 80, or 100 mm, PN 40 or 10/16 flange  Low pressure side: ¼­18 NPT on flange ½­14 NPT on adapter
Rosemount 3051T  ½­14 NPT female  G½ A DIN 16288 male (range 1­4 only)  Autoclave type F-250-C (pressure relieved 9/16­18 gland thread; ¼ OD high pressure tube 60° cone; available for range 5­6
transmitters only).
Rosemount 3051CF  For Rosemount 3051CFA, see Rosemount 485 Annubar Product Data Sheet.  For Rosemount 3051CFC, see Rosemount 405 Compact Orifice Plate Product Data Sheet.

Emerson.com/Rosemount

87

Rosemount 3051

April 2021

 For Rosemount 3051CFP, see Rosemount 1195 Integral Orifice Product Data Sheet.

Process-wetted parts

Drain/vent valves 316 SST, alloy C-276, or alloy 400 material (alloy 400 not available with Rosemount 3051L)

Transmitter flanges and adapters  Plated CS  SST: CF-8M (Cast 316 SST) per ASTM A743  Cast C-276: CW-12MW per ASTM A494  Cast Alloy 400: M-30C per ASTM A494

Wetted O-rings Glass-filled PTFE or graphite-filled PTFE

Process isolating diaphragms

Isolating diaphragm material 316L SST (UNS S31603) Alloy C-276 (UNS N10276) Alloy 400 (UNS N04400) Tantalum (UNS R05440) Gold-plated alloy 400 Gold-plated 316L SST

3051CD, 3051CG · · · · · ·

3051T · · N/A N/A N/A ·

3051CA · · · N/A · ·

Rosemount 3051L process wetted parts Flanged process connection (transmitter high side)

Process diaphragms, including process gasket surface Extension
Mounting flange

316L SST, Alloy C-276, or Tantalum
CF-3M (Cast version of 316L SST, material per ASTM-A743), or Alloy C-276. Fits schedule 40 and 80 pipe. Zinc-cobalt plated CS or SST

Reference process connection (transmitter low side)

Isolating diaphragms Reference flange and adapter

316L SST or Alloy C-276 CF-8M (cast version of 316 SST, material per ASTM-A743)

Non-wetted parts
Electronics housing Low-copper aluminum or CF-8M (cast version of 316 SST) Enclosure type 4X, IP65, IP66, IP68 Housing material code P: PBT/PC with NEMA 4X and IP66/67/68

88

Emerson.com/Rosemount

April 2021

Rosemount 3051

Coplanar sensor housing module SST: CF-3M (Cast 316L SST)
Bolts  Plated CS per ASTM A449, Type 1  Austenitic 316 SST per ASTM F593  ASTM A193, Grade B7M alloy steel  Alloy K-500
Sensor module fill fluid  Coplanar: silicone or inert halocarbon
In-line: silicone or FluorinertTM FC-43
Process fill fluid (Rosemount 3051L only) Syltherm XLT, D.C. Silicone 704, D.C. silicone 200, inert, glycerin and water, Neobee M-20, or propylene glycol and water
Paint Polyurethane
Cover O-rings  Buna-N  Silicone (for wireless option code X)
Power module Field replaceable, keyed connection eliminates the risk of incorrect installation, Intrinsically Safe lithium-thionyl chloride power module with PBT enclosure.

Shipping weights

Note Transmitter weights include the sensor module and housing only (aluminum for Rosemount 3051 and polymer for wireless).

Table 6: Transmitter Weights without Options

Rosemount transmitter

Rosemount 3051 in lb. (kg)

Wireless in lb. (kg)

3051C

6.0 (2.7)

3.9 (1.8)

3051T

3.0 (1.4)

1.9 (0.86)

3051L

Table 7

Table 7

Table 7: Rosemount 3051L Weights without Options

Flange 2-in., Class 150 3-in., Class 150 4-in., Class 150 2-in., Class 300

Flush lb (kg) 12.5 (5.7) 17.5 (7.9) 23.5 (10.7) 17.5 (7.9)

2-in. ext. lb (kg) N/A 19.5 (8.8) 26.5 (12.0) N/A

3-in., Class 300 4-in., Class 300

22.5 (10.2) 32.5 (14.7)

24.5 (11.1) 35.5 (16.1)

4-in. ext. lb (kg) N/A 20.5 (9.3) 28.5 (12.9) N/A 25.5 (11.6) 37.5 (17.0)

6-in. ext. lb (kg) N/A 21.5 (9.7) 30.5 (13.8) N/A 26.5 (12.0) 39.5 (17.9)

Emerson.com/Rosemount

89

Rosemount 3051

April 2021

Table 7: Rosemount 3051L Weights without Options (continued)

Flange

Flush lb (kg)

2-in. ext. lb (kg)

2-in., Class 600

15.3 (6.9)

N/A

3-in., Class 600

25.2 (11.4)

27.2 (12.3)

DN 50/ PN 40

13.8 (6.2)

N/A

DN 80/ PN 40

19.5 (8.8)

21.5 (9.7)

DN 100/ PN 10/16

17.8 (8.1)

19.8 (9.0)

DN 100/ PN 40

23.2 (10.5)

25.2 (11.5)

4-in. ext. lb (kg) N/A 28.2 (12.8) N/A 22.5 (10.2) 20.8 (9.5) 26.2 (11.9)

6-in. ext. lb (kg) N/A 29.2 (13.2) N/A 23.5 (10.6) 21.8 (9.9) 27.2 (12.3)

Table 8: Transmitter Option Weights Code J, K, L, M J, K, L, M M4/M5 M5 B4 B1, B2, B3 B7, B8, B9 BA, BC H2 H3 H4 H7 FC FD FA FB FP FQ WSM N/A

Option

Add lb. (kg)

SST housing (T)

3.9 (1.8)

SST housing (C, L, H, P)

3.1 (1.4)

LCD display for wired transmitter

0.5 (0.2)

LCD display for wireless output

0.1 (0.04)

SST mounting bracket for coplanar flange 1.0 (0.5)

Mounting bracket for traditional flange 2.3 (1.0)

Mounting bracket for traditional flange 2.3 (1.0)

SST bracket for traditional flange

2.3 (1.0)

Traditional flange

2.4 (1.1)

Traditional flange

2.7 (1.2)

Traditional flange

2.6 (1.2)

Traditional flange

2.5 (1.1)

Level flange -- 3 in., 150

10.8 (4.9)

Level flange -- 3 in., 300

14.3 (6.5)

Level flange -- 2 in., 150

10.7 (4.8)

Level flange -- 2 in., 300

14.0 (6.3)

DIN level flange, SST, DN 50, PN 40

8.3 (3.8)

DIN level flange, SST, DN 80, PN 40

13.7 (6.2)

SST sensor module

1.0 (0.45)

Power module (701PGNKF)

0.4 (0.18)

90

Emerson.com/Rosemount

April 2021
Rosemount 3051 product certifications
Rev 2.13

Rosemount 3051

European directive information
A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount.

Ordinary location certification
As standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

North America

E5 USA Explosionproof (XP) and Dust-Ignitionproof (DIP)
Ranges 1-5 (HART) Certificate FM16US0121 Standards FM Class 3600 ­ 2018, FM Class 3615 ­ 2018, FM Class 3616 - 2011, FM Class 3810 ­ 2005, ANSI/NEMA 250 ­ 2008 Markings XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1, GP E, F, G; CL III; T5(-50 °C  Ta  +85 °C); Factory Sealed; Type 4X
Range 1-6 (HART/Fieldbus/)
Certificate 1053834 Standards ANSI/ISA 12.27.01-2003, CSA Std. C22.2 No. 30 -M1986, CSA Std. C22.2 No.142-M1987, CSA Std. C22.2 No. 213 -
M1987 Markings XP Class I, Division 1, Groups B, C and D, T5, (-50 °C  Ta  85 °C) Suitable for Class I, Zone 1, Group IIB+H2, T5; DIP
Class II and Class III, Division 1, Groups E, F and G, T5, (-50 °C  Ta 85 °C) ; Type 4X; Factory Sealed; Single Seal (See drawing 03031-1053)

I5 USA Intrinsic Safety (IS) and Nonincendive (NI)
Range 1-5 (HART)
Certificate FM16US0120X Standards FM Class 3600 - 2011, FM Class 3610 - 2010, FM Class 3611 - 2004, FM Class 3810 - 2005, ANSI/NEMA 250 - 2008 Markings IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F, G; Class III; DIV 1 when connected per Rosemount drawing
03031-1019; NI CL 1, DIV 2, GP A, B, C, D; T4 (­50 °C  Ta  +70 °C) [HART], T4 (­50 °C  Ta  +60 °C) [Fieldbus/ PROFIBUS]; Type 4X
Special Conditions for Safe Use (X): 1. The Rosemount 3051 Transmitter housing contains aluminum and is considered a potential risk of ignition by impact or friction. Care must be taken into account during installation and use to prevent impact and friction.

Emerson.com/Rosemount

91

Rosemount 3051

April 2021

2. The Rosemount 3051 Transmitter with the transient terminal block (Option code T1) will not pass the 500 Vrms dielectric strength test, and this must be taken into account during installation.

Range 1-6 (HART/Fieldbus/PROFIBUS)

Certificate 1053834

Standards ANSI/ISA 12.27.01-2003, CSA Std. C22.2 No.142-M1987, CSA Std. C22.2. No.157-92

Markings

IS Class I, II, III, Division 1 Groups A, B, C, D, E, F, and G when connected in accordance with Rosemount drawing 03031-1024, Suitable for Class I, Zone 0 Group IIC; Class I, Division 2, Groups A, B, C, and D; NIFW; Suitable for Class I, Zone 2, Group IIC; HART: T4 (­60 °C  Ta  +70 °C), T5 (­60 °C  Ta  +40 °C) Fieldbus/PROFIBUS: T4 (­60 °C  Ta  +60 °C) Type 4X

IE USA FISCO
Range 1-5 (HART)
Certificate FM16US0120X Standards FM Class 3600 - 2011, FM Class 3610 - 2010, FM Class 3611 - 2004, FM Class 3810 - 2005 Markings IS CL I, DIV 1, GP A, B, C, D when connected per Rosemount drawing 03031-1019 (­50 °C  Ta  +60 °C); Type 4X
Special Conditions for Safe Use (X): 1. The Rosemount 3051 Transmitter housing contains aluminum and is considered a potential risk of ignition by impact or friction. Care must be taken into account during installation and use to prevent impact and friction. 2. The Rosemount 3051 Transmitter with the transient terminal block (Option code T1) will not pass the 500 Vrms dielectric strength test, and this must be taken into account during installation.
Range 1-6 (HART/Fieldbus/PROFIBUS)
Certificate 1053834 Standards ANSI/ISA 12.27.01-2003, CSA Std. C22.2 No.142-M1987, CSA Std. C22.2. No.157-92 Markings IS Class I, Division 1 Groups A, B, C, D, T4 (-60 °C  Ta  +60 °C) when connected in accordance with Rosemount
drawing 03031-1024, Suitable for Class I, Zone 0 Group IIC; Type 4X; Factory Sealed; Single Seal (See drawing 03031-1053)

C6 Canada Explosionproof, Dust-Ignitionproof, Intrinsic Safety and Nonincendive

Certificate 1053834

Standards ANSI/ISA 12.27.01-2003, CSA Std. C22.2 No. 30 -M1986, CSA Std. C22.2 No.142-M1987, CSA Std. C22.2. No.157-92, CSA Std. C22.2 No. 213 - M1987

Markings

Explosionproof for Class I, Division 1, Groups B, C and D; Suitable for Class I, Zone 1, Group IIB+H2, T5 (­50 °C  Ta  +85 °C);
Dust-Ignitionproof Class II, III Division 1, Groups E, F, G; T5 (­50 °C  Ta  +85 °C); Intrinsically Safe Class I, Division 1, Groups A, B, C, D when connected in accordance with Rosemount drawing 03031-1024, Temperature Code T4; Suitable for Class I, Zone 0;
Class I Division 2 Groups A, B, C, and D, T5; Suitable for Class I Zone 2, Group IIC; Type 4X; Factory Sealed; Single Seal (See drawing 03031-1053)

E6 Canada Explosionproof, Dust-Ignitionproof and Division 2
Certificate 1053834

92

Emerson.com/Rosemount

April 2021

Rosemount 3051

Standards ANSI/ISA 12.27.01-2003, CSA Std. C22.2 No. 30 -M1986, CSA Std. C22.2 No.142-M1987, CSA Std. C22.2 No. 213 M1987

Markings

Explosionproof Class I, Division 1, Groups B, C, and D; Suitable for Class I, Zone 1, Group IIB+H2, T5;
Dust-Ignitionproof for Class II and Class III, Division 1, Groups E, F, and G; T5 (­50 °C  Ta  +85 °C);
Class I, Division 2, Groups A, B, C, and D; T5; Suitable for Class I Zone 2, Group IIC; Type 4X; Factory Sealed; Single Seal (See drawing 03031-1053)

Europe

E8 ATEX Flameproof and Dust

Certificate

KEMA00ATEX2013X; Baseefa11ATEX0275X

Standards Used EN60079-0:2012 + A11:2013, EN60079-1:2014, EN60079-26:2015, EN60079-31:2009

Markings

II ½ G Ex db IIC T6...T4 Ga/Gb T6 (­60 °C  Ta +70 °C), T4/T5 (­60 °C  Ta  +80 °C); II 1 D Ex ta IIIC T95 °C T500105 °C Da (-20 °C  Ta  +85 °C)

Table 9: Process Temperature

Temperature class T6 T5 T4

Process connection temperature ­60 °C to +70 °C ­60 °C to +80 °C ­60 °C to +120 °C

Special Conditions for Safe Use (X):
1. This device contains a thin wall diaphragm less than 1 mm thick that forms a boundary between Category 1 (process connection) and Category 2 (all other parts of the equipment). The model code and datasheet are to be consulted for details of the diaphragm material. During installation, maintenance, and use, the environmental conditions to which the diaphragm will be subjected shall be taken into account. The manufacturer's instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime.
2. Flameproof joints are not intended for repair.
3. Non-standard paint options may cause risk from electrostatic discharge. Avoid installations that could cause electrostatic build-up on painted surfaces and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information.
4. Some variants of the equipment have reduced markings on the nameplate. Refer to the Certificate for full equipment marking.

I1 ATEX Intrinsic Safety and Dust

Certificate Standards Markings

BAS97ATEX1089X; Baseefa11ATEX0275X
EN60079-0:2012 + A11:2013, EN60079-11:2012, EN60079-31:2014
HART: II 1 G Ex ia IIC T5/T4 Ga, T5 (-60 °C  Ta  +40 °C), T4 (-60 °C  Ta  +70 °C) Fieldbus/PROFIBUS: II 1 G Ex ia IIC Ga T4 (-60 °C  Ta  +60 °C) DUST: II 1 D Ex ta IIIC T95 °C T500 105 °C Da (-20 °C  Ta  +85 °C)

Emerson.com/Rosemount

93

Rosemount 3051

April 2021

Table 10: Input Parameters
Voltage Ui Current Ii Power Pi Capacitance Ci Inductance Li

HART 30 V 200 mA 0.9 W 0.012 µF 0 mH

Fieldbus/PROFIBUS 30 V
300 mA 1.3 W 0 µF 0 mH

Special Conditions for Safe Use (X):
1. The apparatus is not capable of withstanding the 500 V insulation test required by clause 6.3.12 of EN60079-11: 2012. This must be taken into account when installing the apparatus.
2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion of located in Zone 0.
3. Some variants of the equipment have reduced markings on the nameplate. Refer to the Certificate for full equipment marking.

IA ATEX FISCO

Certificate

BAS97ATEX1089X

Standards

EN60079-0:2012 + A11:2013, EN60079-11:2012

Markings

II 1 G Ex ia IIC T4 Ga (­60 °C  Ta  +60 °C)

Table 11: Input Parameters

Voltage Ui Current Ii Power Pi Capacitance Ci Inductance Li

Fieldbus/PROFIBUS 17.5 V 380 mA 5.32 W 5 nF 10 µH

Special Conditions for Safe Use (X):
1. The apparatus is not capable of withstanding the 500 V insulation test required by clause 6.3.12 of EN60079-11: 2012. This must be taken into account when installing the apparatus.
2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion of located in Zone 0.

N1 ATEX Type n and Dust

Certificate Standards Markings

BAS00ATEX3105X; Baseefa11ATEX0275X EN60079-0:2012 + A11:2013, EN60079-15:2010, EN60079-31:2014
II 3 G Ex nA IIC T5 Gc (­40 °C  Ta  +70 °C); II 1 D Ex ta IIIC T95 °C T500 105 °C Da (­20 °C  Ta  +85 °C)

94

Emerson.com/Rosemount

April 2021

Rosemount 3051

Special Conditions for Safe Use (X):
1. This apparatus is not capable of withstanding the 500 V insulation test that is required by clause 6.8.1 of EN60079-15. This must be taken into account when installing the apparatus.
2. Some variants of the equipment have reduced markings on the nameplate. Refer to the Certificate for full equipment marking.

International

E7 IECEx Flameproof and Dust

Certificate IECEx KEM 09.0034X; IECEx BAS 10.0034X Standards IEC60079-0:2011, IEC60079-1:2014-06, IEC60079-26:2014-10, IEC60079-31:2013 Markings Ex db IIC T6...T4 Ga/Gb T6(­60 °C  Ta  +70 °C), T4/T5(­60 °C  Ta  +80 °C); Ex ta IIIC T95 °C T500105 °C Da (-20 °C 
Ta  +85 °C) Table 12: Process Temperature

Temperature class T6 T5 T4

Process connection temperature ­60 °C to +70 °C ­60 °C to +80 °C ­60 °C to +120 °C

Special Conditions for Safe Use (X):
1. This device contains a thin wall diaphragm less than 1 mm thick that forms a boundary between EPL Ga (process connection) and EPL Gb (all other parts of the equipment). The model code and datasheet are to be consulted for details of the diaphragm material. During installation, maintenance, and use, the environmental conditions to which the diaphragm will be subjected shall be taken into account. The manufacturer's instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime.
2. Flameproof joints are not intended for repair.
3. Non-standard paint options may cause risk from electrostatic discharge. Avoid installations that could cause electrostatic build-up on painted surfaces and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information.
4. Some variants of the equipment have reduced markings on the nameplate. Refer to the Certificate for full equipment marking.

I7 IECEx Intrinsic Safety

Certificate

IECEx BAS 09.0076X

Standards

IEC60079-0:2011, IEC60079-11:2011

Markings

HART: Ex ia IIC T5/T4 Ga, T5(-60 °C  Ta  +40 °C), T4 (-60 °C  Ta  +70 °C) Fieldbus/PROFIBUS: Ex ia IIC T4(­60 °C  Ta  +60 °C)

Table 13: Input Parameters

Voltage Ui

HART 30 V

Fieldbus/PROFIBUS 30 V

Emerson.com/Rosemount

95

Rosemount 3051

April 2021

Table 13: Input Parameters (continued)
Current Ii Power Pi Capacitance Ci Inductance Li

HART 200 mA 0.9 W 0.012 µF
0 mH

Fieldbus/PROFIBUS 300 mA 1.3 W 0 µF 0 mH

Special Conditions for Safe Use (X):
1. If the apparatus is fitted with an optional 90 V transient suppressor, it is not capable of withstanding the 500 V insulation test required by clause 6.3.12 of IEC 60079-11. This must be taken into account when installing the apparatus.
2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion of located in Zone 0.

IECEx Mining (Special A0259)

Certificate Standards Markings Table 14: Input Parameters

IECEx TSA 14.0001X IEC60079-0:2011, IEC60079-11:2011 Ex ia I Ma (­60 °C  Ta  +70 °C)

Voltage Ui Current Ii Power Pi Capacitance Ci Inductance Li

HART 30 V 200 mA 0.9 W 0.012 µF 0 mH

Fieldbus/PROFIBUS 30 V
300 mA 1.3 W 0 µF 0 mH

FISCO 17.5 V 380 mA 5.32 W <5 nF <10 µH

Special Conditions for Safe Use (X):
1. If the apparatus is fitted with an optional 90 V transient suppressor, it is not capable of withstanding the 500 V insulation test required by IEC60079-11. This must be taken into account when installing the apparatus.
2. It is a condition of safe use that the above input parameters shall be taken into account during installation.
3. It is a condition of manufacture that only the apparatus fitted with housing, covers, and sensor module housing made out of stainless steel are used in Group 1 applications.

IG IECEx FISCO
Certificate Standards Markings Table 15: Input Parameters

IECEx BAS 09.0076X IEC60079-0:2011, IEC60079-11:2011 Ex ia IIC T4 Ga (-60 °C  Ta  +60 °C)

Voltage Ui

Fieldbus/PROFIBUS 17.5 V

96

Emerson.com/Rosemount

April 2021

Rosemount 3051

Current Ii Power Pi Capacitance Ci Inductance Li

Table 15: Input Parameters (continued) Fieldbus/PROFIBUS 380 mA 5.32 W  5 nF  10 µH

Special Conditions for Safe Use (X):
1. If the apparatus is fitted with an optional 90 V transient suppressor, it is not capable of withstanding the 500 V insulation test required by clause 6.3.12 of IEC 60079-11. This must be taken into account when installing the apparatus.
2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion of located in Zone 0.

N7 IECEx Type n

Certificate Standards Markings

IECEx BAS 09.0077X IEC60079-0:2011, IEC60079-15:2010 Ex nA IIC T5 Gc (-40 °C  Ta  +70 °C)

Special Condition for Safe Use (X):
1. This apparatus is not capable of withstanding the 500 V insulation test required by clause 6.5.1 of IEC 60079-15. This must be taken into account when installing the apparatus.

Brazil

E2 INMETRO Flameproof

Certificate Standards Markings

UL-BR 13.0643X ABNT NBR IEC 60079-0:2013; ABNT NBR IEC 60079-1:2016; ABNT NBR IEC 60079-26:2016 Ex db IIC T6...T4 Ga/Gb, T6(­60 °C  Ta  +70 °C), T4/T5 (­60 °C  Ta  +80 °C)

Special Conditions for Safe Use (X):
1. This device contains a thin wall diaphragm with less than 1 mm thickness that forms a boundary between zone 0 (process connection) and zone 1 (all other parts of the equipment). The model code and datasheet are to be consulted for details of the diaphragm material. Installation, maintenance, and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer's instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime.
2. Flameproof joints are not intended for repair.
3. Non-standard paint options may cause risk from electrostatic discharge. Avoid installations that could cause electrostatic build-up on painted surfaces and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information.

I2 INMETRO Intrinsic Safety

Certificate

UL-BR 13.0584X

Emerson.com/Rosemount

97

Rosemount 3051

April 2021

Standards

ABNT NBR IEC60079-0:2013, ABNT NBR IEC60079-11:2013

Markings

HART: Ex ia IIC T5/T4 Ga, T5(­60 °C  Ta  +40 °C), T4 (­60 °C  Ta  +70 °C) Fieldbus/PROFIBUS: Ex ia IIC T4 Ga (­60 °C  Ta  +60 °C)

Table 16: Input Parameters

Voltage Ui Current Ii Power Pi Capacitance Ci Inductance Li

HART 30 V 200 mA 0.9 W 0.012 µF 0 mH

Fieldbus/PROFIBUS 30 V 300 mA 1.3 W 0 µF 0 mH

Special Conditions for Safe Use (X):
1. If the equipment is fitted with an optional 90 V transient suppressor, it is not capable of withstanding the 500 V insulation test required by ABNT NBR IRC 60079-11. This must be taken into account when installing the equipment.
2. The enclosure may be made of aluminum alloy and given protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if equipment requires EPL Ga.

IB INMETRO FISCO

Certificate

UL-BR 13.0584X

Standards

ABNT NBR IEC60079-0:2013, ABNT NBR IEC60079-11:2013

Markings

Ex ia IIC T4 Ga (-60 °C  Ta  +60 °C)

Table 17: Input Parameters

Voltage Ui Current Ii Power Pi Capacitance Ci Inductance Li

FISCO 17.5 V 380 mA 5.32 W 5 nF 10 µH

Special Conditions for Safe Use (X):
1. If the equipment is fitted with an optional 90 V transient suppressor, it is not capable of withstanding the 500 V insulation test required by ABNT NBR IEC 60079-11. This must be taken into account when installing the equipment.
2. The enclosure may be made of aluminum alloy and given protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if equipment requires EPL Ga.

98

Emerson.com/Rosemount

April 2021

Rosemount 3051

China

E3 China Flameproof

Certificate Standards Markings

GYJ19.1056X [Transmitters]; GYJ20.1486X [Flow meters]
GB3836.1-2010, GB3836.2-2010, GB3836.20-2010, GB12476.1-2013, GB12476.5-2013
3051 Series: Ex d IIC T6 ~ T4 Ga/Gb, Ex tD A20 IP66 T95 °C T500 105 °C (-20 °C  Ta  +85 °C) 3051CF Series: Ex d IIC T5/T6 Ga/Gb

I3 China Intrinsic Safety

Certificate Standards Markings

GYJ18.1419X; GYJ20.1488X [Flow meters]
GB3836.1-2010, GB3836.4-2010, GB3836.20-2010, GB12476.1-2000
3051 Series: Ex ia IIC T4/T5 Ga, DIP A20 TA 80 °C IP66 3051 CF Series: Ex ia IIC T4/T5 Ga

N3 China Type n
Certificate Standards Markings

GYJ20.1110X GB3836.1-2010, GB3836.8-2014 Ex nA IIC T5 Gc (-40 °C  Ta  +70 °C)

Japan
E4 Japan Flameproof
Certificate TC20577, TC20578, TC20583, TC20584 [HART]; TC20579, TC20580, TC20581, TC20582 [Fieldbus] Markings Ex d IIC T5

Republic of Korea

EP Republic of Korea Flameproof

Certificate Markings

11-KB4BO-0188X [Mfg Singapore], 19-KA4BO-079X [Mfg USA] Ex d IIC T6...T4 Ga/Gb

IP Republic of Korea Intrinsic Safety
Certificate 13-KB4BO-0203X [HART ­ Mfg USA], 13-KB4BO-0204X [Fieldbus ­ Mfg USA], 10-KB4BO-0138X [HART ­ Mfg Singapore], 13-KB4BO-0206X [Fieldbus ­ Mfg Singapore] 18-KA4BO-0354X [HART ­ Mfg USA], 18-KA4BO-0355X [Fieldbus ­ Mfg USA]
Markings Ex ia IIC T5/T4 (HART); Ex ia IIC T4 (Fieldbus)

Emerson.com/Rosemount

99

Rosemount 3051

Technical Regulations Customs Union (EAC)

EM EAC Flameproof

Markings

Ga/Gb Ex db IIC T4...T6 X, T4/T5(-60 °C  Ta  +80 °C), T6(-60 °C  Ta  +70 °C)

Special Condition for Safe Use (X): See certificate for special conditions.

IM EAC Intrinsically Safe

Markings

HART: 0Ex ia IIC T4/T5 Ga X, T4(­60 °C  Ta  +70 °C), T5(-60 °C  Ta  +40 °C) Fieldbus/PROFIBUS: 0Ex ia IIC T4 Ga X (­60 °C  Ta  +60 °C)

Special Condition for Safe Use (X) See certificate for special conditions.

Combinations

K2

Combination of E2 and I2

K5

Combination of E5 and I5

K6

Combination of C6, E8, and I1

K7

Combination of E7, I7, and N7

K8

Combination of E8, I1, and N1

KB

Combination of E5, I5, and C6

KD

Combination of E8, I1, E5, I5, and C6

KM

Combination of EM and IM

KP

Combination of EP and IP

April 2021

Additional certifications
SBS American Bureau of Shipping (ABS) Type Approval
Certificate 18-HS1814795-PDA Intended use Marine & Offshore Applications ­ Measurement of either gauge or absolute pressure for liquid, gas and vapor.
SBV Bureau Veritas (BV) Type Approval
Certificate 23155 Requirements Bureau Veritas rules for the classification of steel ships Application Class notations: AUT-UMS, AUT-CCS, AUT-PORT and AUT-IMS; Pressure transmitter type 3051 cannot be installed
on diesel engines

100

Emerson.com/Rosemount

April 2021

SDN Det Norske Veritas (DNV) Type Approval

Certificate Intended Use Application

TAA000004F DNV GL rules for classification - ships and offshore units Table 18: Location Classes

Temperature

D

Humidity

B

Vibration

A

EMC

B

Enclosure

D

SLL Lloyds Register (LR) Type Approval

Certificate Application

11/60002 Environmental categories ENV1, ENV2, ENV3, and ENV5

C5 Custody Transfer - Measurement Canada Accuracy Approval

Certificate

AG-0226; AG-0454; AG-0477

Rosemount 3051

Emerson.com/Rosemount

101

Rosemount 3051
EU Declaration of conformity

April 2021

102

Emerson.com/Rosemount

April 2021

Rosemount 3051

Emerson.com/Rosemount

103

Rosemount 3051

April 2021

104

Emerson.com/Rosemount

April 2021

Rosemount 3051

Emerson.com/Rosemount

105

Rosemount 3051
China RoHS

April 2021

106

Emerson.com/Rosemount

April 2021

Rosemount 3051

Rosemount 3051 Wireless product certifications
Rev 1.10

European Directive information
A copy of the EU Declaration of Conformity can be found at the end of this guide The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount.
Telecommunications compliance
All wireless devices require certification to ensure they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
FCC and IC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference; this device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons.

Ordinary location certification
As standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

Installing equipment in North America
The US National Electrical Code® (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective codes.

USA

I5 U.S.A. Intrinsically Safe (IS)

Ranges 1-5 Certificate
Standards

FM19US0050X
FM Class 3600:2018, FM Class 3610:2018, FM Class 3810:2018, ANSI/ISA 60079-0:2013, ANSI/UL 60079-11:2014, NEMA 250:2003, ANSI/IEC 60529:2014, ANSI/UL 61010:2016

Emerson.com/Rosemount

107

Rosemount 3051

April 2021

Markings

IS CL I, DIV 1, GP A, B, C, D T4; CL 1, Zone 0 AEx ia IIC T4; T4(­40 °C  Ta  +70 °C) when installed per Rosemount drawing 03031-1062; Type 4X/IP66/IP68

Special Conditions for Safe Use (X):
1. The Rosemount 3051 Wireless Pressure Transmitter shall only be used with the 701PGNKF Rosemount SmartPowerTM Battery Pack.
2. The inline pressure sensor may contain more than 10 percent aluminum and is considered a potential risk of ignition by impact or friction. Care must be taken into account during installation and used to prevent impact and friction.
3. The surface resistivity of the transmitter housing is greater than one gigaohm. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.

Range 6 Certificate Standards
Markings

CSA 2526009
FM Class 3600 - 2011, FM Class 3610 - 2010, FM Class 3810 - 2005, ANSI/ISA 60079-0 - 2009, ANSI/ISA 60079-11 - 2009, UL 61010-1 (3rd edition), UL50E (1st Edition) IS CL I, DIV 1, GP A, B, C, D T4; CL 1, Zone 0 AEx ia IIC T4; T4(-40 °C  Ta  +70 °C) when installed per Rosemount drawing 03031-1063; Type 4X/IP66/IP68

Canada
I6 Canada Intrinsically Safe
Certificate CSA 2526009 Standards CAN/CSA C22.2 No. 0-M91, CAN/CSA C22.2 No.94-M91, CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No. 157-92,
CSA Std C22.2 No. 60529:05 Markings Intrinsically Safe for Class I, Division 1, Groups A, B, C, D, T4 when installed per Rosemount drawing 03031-1063;
Type 4X/IP66/IP68

Europe

I1 ATEX Intrinsic Safety

Certificate Standards Markings

Baseefa12ATEX0228X EN 60079-0: 2012, EN 60079-11: 2012
Ex II 1 G Ex ia IIC T4 Ga, T4(­60 °C  Ta  +70 °C) IP66/IP68

Special Conditions for Safe Use (X):
1. The plastic enclosure may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.
2. The Model 701PGNKF Power Module may be replaced in a hazardous area. The power module has a surface resistivity greater than 1 G and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.

108

Emerson.com/Rosemount

April 2021

Rosemount 3051

International

I7 IECEx Intrinsic Safety

Certificate Standards Markings

IECEx BAS 12.0124X IEC 60079-0: 2011, IEC 60079-11: 2011 Ex ia IIC T4 Ga, T4(­60 °C  Ta  +70 °C) IP66/IP68

Special Conditions for Safe Use (X):
1. The plastic enclosure may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.
2. The Emerson 701PGNKF Power Module may be replaced in a hazardous area. The power module has a surface resistivity greater than 1 G and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up.

Brazil

I2 INMETRO Intrinsic Safety

Certificate Standards Markings

UL-BR 13.0534X ABNT NBR IEC 60079-0:2008 + Errata 1:2011, ABNT NBR IEC 60079-11:2009 Ex ia IIC T4 IP66 Ga, T4(­40 °C  Ta  +70 °C)

Special Condition for Safe Use (X): See certificate for special conditions.

China

I3 China Intrinsic Safety

Certificate Standards Markings

: GYJ18.1419X; GYJ20.1488X [Flow Meters] GB3836.1-2010, GB3836.4-2010, GB3836.20-2010 Ex ia IIC T4 Ga, T4(­60 ~ +70 °C)

Special Conditions for Safe Use (X): See certificate for special conditions.

Japan

I4 TIIS Intrinsic Safety
Certificate TC22022X (Rosemount 3051C/L), TC22023X (Rosemount 3051T), TC22024X (Rosemount 3051CFx) Markings Ex ia IIC T4 Ga, T4(­20 ~ +60 °C)

Emerson.com/Rosemount

109

Rosemount 3051
Special Conditions for Safe Use (X): See certificate for special conditions.

April 2021

EAC ­ Belarus, Kazakhstan, Russia

IM Technical Regulation Customs Union (EAC) Intrinsic Safety

Certificate Markings

EAC RU C-US.EX01.B.00176/20 0Ex ia IIC T4 Ga X; (­60 °C  Ta  +70 °C)

Special Condition for Safe Use (X): See certificate for special conditions.

Korea

IP Korea Intrinsic Safety

Certificate Markings

13-KB4BO-0295X Ex ia IIC T4 (­40 °C  Ta  +70 °C)

Special Conditions for Safe Use (X): See certificate for special conditions.

Additional Certifications

SBS American Bureau of Shipping (ABS) Type Approval
Certificate 15-HS1405241-PDA Intended Use Marine & Offshore Applications - Measurement of either gauge or absolute pressure for liquid, gas and vapor.

SBV Bureau Veritas (BV) Type Approval
Certificate 23155 Requirements Bureau Veritas Rules for the Classification of Steel Ships Application Class notations: AUT-UMS, AUT-CCS, AUT-PORT and AUT-IMS; Pressure transmitter type 3051 cannot be installed
on diesel engines

SDN Det Norske Veritas (DNV) Type Approval

Certificate Intended Use

TAA000004F DNV GL Rules for Classification - Ships and offshore units

Application:

110

Emerson.com/Rosemount

April 2021

Location classes

Temperature

D

Humidity

B

Vibration

A

EMC

B

Enclosure

D

Rosemount 3051

Emerson.com/Rosemount

111

Rosemount 3051

April 2021

Dimensional drawings
Note This section contains dimensional drawings for output codes A, F and X. For output codes W and M, visit Emerson.com/en-us/ support. Figure 7: Rosemount 3051C Exploded View
F
E D C B
A G

H I
J

K

N

L O

M

P

Q

A. Cover B. Cover O-ring C. Terminal block D. Electronics housing E. Configuration buttons cover F. Local configuration buttons

G. Electronics board H. Name plate I. Housing rotation set screw (180 degree maximum rotation without further disassembly) J. Sensor module K. Coplanar flange

L. Drain/vent valve M. Flange adapters N. Process O-ring O. Flange adapter O-ring P. Flange alignment screw (not pressure retaining) Q. Flange bolts

112

Emerson.com/Rosemount

April 2021 Figure 8: Rosemount 3051C Coplanar Flange
4.09 (104)
7.12 (181)

Rosemount 3051
4.29 (109)

Dimensions are in inches (millimeters).
Figure 9: Rosemount 3051 Wireless Housing with Coplanar Flange
4.196 (106.6)

6.55 (166)
5.49 (139)

Dimensions are in inches (millimeters).

7.41 (188)

Emerson.com/Rosemount

113

Rosemount 3051

April 2021

Figure 10: Rosemount 3051C Coplanar Flange with Rosemount 305RC3 3-Valve Coplanar Integral Manifold

6.75 (171)

5.50 (140) Max open
Dimensions are in inches (millimeters).

9.20 (234) Max Open

Figure 11: Coplanar Flange Mounting Configurations with Optional Bracket (B4) for 2-in. Pipe or Panel Mounting

Panel mounting

2.81

A

(71)

6.20 (157)

2.81 (71)
4.73 (120)

B
3.35 (85)

114

Emerson.com/Rosemount

April 2021 Pipe mounting
6.25 (159)
A. 5/16-18 bolts (not supplied) B. -16 bolts C. 2-in. U-bolt D. -16 bolts Dimensions are in inches (millimeters).

Rosemount 3051
C
D 3.35 (85)
3.50 (89)

Emerson.com/Rosemount

115

Rosemount 3051
Figure 12: Rosemount 3051C Coplanar with Traditional Flange
4.09 (104)

April 2021

1.63 (41)

1.16 3.40

(29)

(86)

A. Flange adapters (optional)

A 1.10 (28)

2.13 (54)

Dimensions are in inches (millimeters).

Figure 13: Rosemount 3051C Coplanar with Rosemount 305RT3 3-Valve Traditional Integral Manifold

6.28 (159)
A

3.63 (92)

0.91

3.50

(23)

(89)

A. ½-14 NPT flange adapter (optional) Dimensions are in inches (millimeters).

1.10 (28)

116

2.13

6.38

(54)

2.52

(162)

(64)

Emerson.com/Rosemount

April 2021

Rosemount 3051

Figure 14: Traditional Flange Mounting Configurations with Optional Brackets for 2-in. Pipe or Panel Mounting

Panel mounting bracket (option B2/B8)

Pipe mounting bracket (option B1/B7/BA)

2.62 (67)

9.27 (235)

2.62 (67)

A

6.65 (169)

Pipe mounting bracket (option B3/B9/BC)

2.81 (71)

6.65 (169)

4.85 (123)

1.10 (28)

0.93 (24) 4.12 (105)

3.40 (86)

1.75 (44)

A. 5/16-18 bolts (not supplied) Dimensions are in inches (millimeters).

Emerson.com/Rosemount

117

Rosemount 3051
Figure 15: Rosemount 3051T
4.09 (104)
R1-4: 7.22 (183) R5: 7.32 (186)
Dimensions are in inches (millimeters). Figure 16: Rosemount 3051T Wireless Housing
4.20 (107)
A
A. U-Bolt bracket Dimensions are in inches (millimeters).

4.29 (109)

April 2021

5.49 (139)
R1-4: 7.56 (192) R5: 7.66 (195)

118

Emerson.com/Rosemount

April 2021
Figure 17: Rosemount 3051T In-Line Range 6 In-line

Wireless in-line

Rosemount 3051

7.86 (199,5)
A A. Autoclave type F-250-C Dimensions are in inches (millimeters). Figure 18: Rosemount 3051T with Rosemount 306 2-Valve Integral Manifold

8.13 (206,6)

4.13 (105) Dimensions are in inches (millimeters).
Emerson.com/Rosemount

4.88 (124) 6.25 (159) max open
119

Rosemount 3051

Figure 19: Rosemount 3051T Typical Mounting Configurations with Optional Mounting Bracket

Pipe mounting

Panel mounting

April 2021

3.49 (89)
Dimensions are in inches (millimeters).

6.15 (156)

6.15

(156)

2.81

(71)

4.78 (121)

120

Emerson.com/Rosemount

April 2021

Rosemount 3051

Figure 20: Rosemount 3051CFA Pak-Lok Annubar Flow meter
Note The Pak-Lok Annubar model is available up to ASME B16.5 Class 600 rating (1440 psig at 100 °F [99 bar at 38 °C]).

Front View

Side View

Top View

Table 19: Rosemount 3051CFA Pak-Lok Annubar Flow meter Dimensional Data (Maximum Dimensions)

Sensor size

A

B

C

D

1

8.50 (215.9)

15.60 (396.9)

9.00 (228.6)

6.00 (152.4)

2

11.00 (279.4)

18.10 (460.4)

9.00 (228.6)

6.00 (152.4)

3

12.00 (304.8)

19.10 (485.8)

9.00 (228.6)

6.00 (152.4)

Dimensions are in inches (millimeters).

Emerson.com/Rosemount

121

Rosemount 3051

Figure 21: Rosemount 3051CFC Compact Orifice Flow meter

Compact orifice plate (primary element type code P)

Orifice plate side view
B

Orifice plate front view
D

A

Orifice plate top view
C

April 2021

Conditioning

orifice plate

D

C

(primary

element type

B

code C)

A

Primary element type Type P and C

A

B

Transmitter height

5.62 (143) Transmitter height + A 6.27 (159)

C

D

7.75 (197) - closed 6.00 (152) - closed 8.25 (210) - open 6.25 (159) - open

Dimensions are in inches (millimeters).

122

Emerson.com/Rosemount

April 2021
Figure 22: Rosemount 3051CFP Integral Orifice Flow meter Side view

Rosemount 3051

Bottom view

8.80 (223.46)

A

Front view
5.30 (134.51)

10.30 (261.81)
6.30 (160.55)

K Downstream
A. B.D. (bore diameter) Dimensions are in inches (millimeters).

J Upstream

Dimension J (Beveled/threaded pipe ends) J (RF slip-on, RTJ slip-on, RF-DIN slip on) J (RF Class 150, weld neck) J (RF Class 300, weld neck) J (RF Class 600, weld neck)

Line size ½ -in. (15 mm) 12.54 (318.4) 12.62 (320.4) 14.37 (364.9) 14.56 (369.8) 14.81 (376.0)

Emerson.com/Rosemount

1-in. (25 mm) 20.24 (514.0) 20.32 ( 516.0) 22.37 (568.1) 22.63 (574.7) 22.88 (581.0)

1½-in. (40 mm) 28.44 (722.4) 28.52 (724.4) 30.82 (782.9) 31.06 (789.0) 31.38 (797.1)
123

Rosemount 3051

April 2021

Dimension

Line size ½ -in. (15 mm)

1-in. (25 mm)

1½-in. (40 mm)

K (Beveled/threaded pipe ends)

5.74 (145.7)

K (RF slip-on, RTJ slip-on, RF-DIN slip on) (1) 5.82 (147.8)

8.75 (222.2) 8.83 (224.2)

11.91 (302.6) 11.99 (304.6)

K (RF Class 150, weld neck)

7.57 (192.3)

10.88 (276.3)

14.29 (363.1)

K (RF Class 300, weld neck)

7.76 (197.1)

11.14 (282.9)

14.53 (369.2)

K (RF Class 600, weld neck)

8.01 (203.4)

11.39 (289.2)

14.85 (377.2)

B.D. (Bore diameter) Dimensions are in inches (millimeters).

0.664 (16.87)

1.097 (27.86)

1.567 (39.80)

(1) Downstream length shown here includes plate thickness of 0.162-in. (4.11 mm).

Figure 23: Rosemount 3051L Configurations

2-in. flange Configuration (flush mount only)

3- and 4-in. flange configuration

Diaphragm assembly and mounting flange

4.09 (104)

4.09 (104)

5.13 (130) 4.29 (109)

DC

6.80 (173)

7.10 (181) 8.20
(209)

E

A

B

A B

E. 2-, 4-, or 6-in. extension (only available with 3- and 4-in., DN80, and DN100 flange configurations)

Table 20: Rosemount 3051L Dimensional Specifications

Class(1)

Pipe size

Flange thickness A

ASME B16.5 (ANSI) 150

2 (51)

0.69 (18)

3 (76)

0.88 (22)

4 (102)

0.88 (22)

ASME B16.5 (ANSI) 300

2 (51)

0.82 (21)

3 (76)

1.06 (27)

B
5.65 (143) 5.65 (143) 5.65 (143) 5.65 (143) 5.65 (143)

Extension diameter(1) O.D. gasket

C

surface D

N/A

3.6 (92)

2.58 (66)

5.0 (127)

3.5 (89)

6.2 (158)

N/A

3.6 (92)

2.58 (66)

5.0 (127)

124

Emerson.com/Rosemount

April 2021

Rosemount 3051

Table 20: Rosemount 3051L Dimensional Specifications (continued)

Class(1)

Pipe size

Flange thickness B A

4 (102)

1.19 (30)

5.65 (143)

ASME B16.5 (ANSI) 600

2 (51)

1.00 (25)

7.65 (194)

3 (76)

1.25 (32)

7.65 (194)

DIN 2501 PN 10­40

DN 50

0.79 (20)

5.65 (143)

DIN 2501 PN 25/40

DN 80

0.94 (24)

5.65 (143)

DN 100

0.94 (24)

5.65 (143)

DIN 2501 PN 10/16

DN 100

0.79 (20)

5.65 (143)

Dimensions are in inches (millimeters).

(1) Tolerances are 0.040 (1.02), - 0.020 (0.51).

Extension diameter(1) O.D. gasket

C

surface D

3.5 (89)

6.2 (158)

N/A

3.6 (92)

2.58 (66)

5.0 (127)

N/A

4.0 (102)

2.6 (66)

5.4 (138)

3.5 (89)

6.2 (158)

3.5 (89)

6.2 (158)

Figure 24: Optional Flushing Connection Ring (Lower Housing) for Rosemount 3051L

A

H J

G

J

F

Class(1)
ASME B16.5 (ANSI) 150
ASME B16.5 (ANSI) 300
ASME B16.5 (ANSI) 600 DIN 2501 PN 10­40 DIN 2501 PN 25/40

Pipe size Flange thickness A
2 (51) 0.69 (18) 3 (76) 0.88 (22) 4 (102) 0.88 (22) 2 (51) 0.82 (21) 3 (76) 1.06 (27) 4 (102) 1.19 (30) 2 (51) 1.00 (25). 3 (76) 1.25 (32) DN 50 0.79 (20)
DN 80 0.94 (24)

Lower housing F

Bolt circle

¼-in. NPT ½ -in. NPT diameter G

0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25) 0.97 (25)

1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33) 1.31 (33)

4.75 (121) 6.0 (152) 7.5 (191) 5.0 (127) 6.62 (168) 7.88 (200) 5.0 (127) 6.62 (168) 4.92 (125)

0.97 (25) 1.31 (33) 6.3 (160)

No. of bolts 4 4 8 8 8 8 8 8 4

Bolt hole diameter
0.75 (19) 0.75 (19) 0.75 (19) 0.75 (19) 0.88 (22) 0.88 (22) 0.75 (19) 0.88 (22) 0.71 (18)

Process side H
2.12 (54) 3.60 (91) 3.60 (91) 2.12 (54) 3.60 (91) 3.60 (91) 2.12 (54) 3.60 (91) 2.40 (61)

Outside diameter J
6.0 (152) 7.5 (191) 9.0 (229) 6.5 (165) 8.25 (210) 10.0 (254) 6.5 (165) 8.25 (210) 6.5 (165)

8

0.71 (18) 3.60 (91) 7.87 (200)

Emerson.com/Rosemount

125

Rosemount 3051

April 2021

Class(1)
DIN 2501 PN 10/16

Pipe size Flange thickness A
DN 100 0.94 (24)
DN 100 0.79 (20)

Lower housing F

Bolt circle

¼-in. NPT ½ -in. NPT diameter G

0.97 (25) 0.97 (25)

1.31 (33) 1.31 (33)

7.48 (190) 7.09 (180)

No. of bolts
8
8

Bolt hole diameter
0.88 (22) 0.71 (18)

Process side H
3.60 (91) 3.60 (91)

Outside diameter J
9.25 (235) 8.66 (220)

126

Emerson.com/Rosemount

April 2021

Options

Standard configuration

Unless otherwise specified, transmitter is shipped as follows:

Engineering units Differential/Gage Absolute/Rosemount 3051A/3051TG 4 mA(1) 20 mA(1) Output External buttons Flange type Flange material O-ring material Drain/vent LCD display Alarm(1) Software tag Damping

Setting inH2O (Range 0, 1, 2, and 3) psi (all ranges) 0 (engineering units above) Upper range limit Linear None Specified model code option Specified model code option Specified model code option Specified model code option None High (Blank) 0.4 seconds (2)

(1) Not applicable to FOUNDATION Fieldbus, PROFIBUS PA, or wireless. (2) For Fieldbus Protocols, default damping is one second.

Rosemount 3051

Custom configuration
Note Not applicable to FOUNDATION Fieldbus or PROFIBUS PA Protocols.
If option code C1 is ordered, the customer may specify the following data in addition to the standard configuration parameters.  Output information  Transmitter information  LCD display configuration  Hardware selectable information  Signal selection  Wireless information  Scaled variable Refer to the Rosemount 3051 Configuration Data Sheet for Rosemount 3051 HART® Protocol. For Wireless, refer to the Rosemount 3051 Wireless Configuration Data Sheet.

Emerson.com/Rosemount

127

Rosemount 3051

April 2021

Tagging (three options available)
 Standard SST hardware tag is stamped on the transmitter, 56 characters maximum.  Tag may be wired to the transmitter upon request. Tag character height is 0.125 in. (3.18 mm), 56 characters maximum.  Tag may be stored in transmitter memory. Character limit is dependent on protocol.
-- HART Revision 5: 8 characters
-- HART Revision 7 and Wireless: 32 characters
-- FOUNDATION Fieldbus: 32 characters
-- PROFIBUS PA: 32 characters

Commissioning tag
Note Only applicable to FOUNDATION Fieldbus.
A temporary commissioning tag is attached to all transmitters. The tag indicates the device ID and allows an area for writing the location.

Optional Rosemount 304, 305, or 306 Integral Manifolds
Factory assembled to Rosemount 3051C and 3051T transmitters. Refer to the following Product Data Sheet for Rosemount 304, 305, and 306 for additional information.

Other seals Refer to Rosemount DP Level Transmitters and 1199 Diaphragm Seal System Product Data Sheet for additional information.

Output information Output range points must be the same unit of measure. Available units of measure include:

Pressure

atm mbar bar inH20 inHg hPa(1)(2) m Hg at 0 °C(1)(2)

inH2O at 4 °C(2) mm H2O mm Hg mm H2O at 4 °C(2) ft H20 inH2O at 60 °F(2) psf(1)(2)

g/cm2 kg/cm2 Pa kPa MPa(2) kg/m2 (1)(2) ft H2O at 4 °C(1)(2)

psi
torr cm H2O at 4 °C(1)(2) m H2O at 4 °C(1)(2) ft H2O at 60 °F(1)(2) cmHg at 0 °C(1)(2)

(1) Field configurable only; not available for factory calibration or custom configuration (option code C1 "Software configuration"). (2) Not available with Low Power (output code M) or PROFIBUS PA (output option code W).

Display and interface options M4 Digital display with LOI  Available for 4­20 mA HART and PROFIBUS PA
M5 Digital display  Two-line, five-digit LCD display for low power output  Two-line, eight-digit LCD display for 4­20 mA HART, FOUNDATION Fieldbus, and PROFIBUS PA  Three-line, seven-digit LCD display for Wireless  Direct reading of digital data for higher accuracy

128

Emerson.com/Rosemount

April 2021

Rosemount 3051

 Displays user-defined flow, level, volume, or pressure units  Displays diagnostic messages for local troubleshooting  90-degree rotation capability for easy viewing
Configuration buttons Rosemount 3051 will ship with no buttons unless option D4 (analog zero and span), DZ (digital zero), or M4 (LOI) for local configuration buttons are specified. The Rosemount 3051 Wireless Transmitter is available with a Digital zero button installed with or without the LCD digital display.
Transient protection (option code T1) Tested in accordance with IEEE C62.41.2-2002, location category B  6 kV crest (0.5 µs­100 kHz)  3 kA crest (8 x 20 µs)  6 kV crest (1.2 x 50 µs)
Bolts for flanges and adapters  Options permit bolts for flanges and adapters to be obtained in various materials  Standard material is plated CS per ASTM A449, Type 1  L4 austenitic 316 SST bolts  L5 ASTM A 193, Grade B7M bolts  L6 alloy k-500 bolts
Conduit plug DO option replaces the standard CS plug with 316 SST plug.
Rosemount 3051C Coplanar Flange and 3051T bracket option B4 Bracket for 2-in. pipe or panel mounting  For use with the standard coplanar flange configuration  Bracket for mounting of transmitter on 2-in. pipe or panel  SST construction with SST bolts
Rosemount 3051C Traditional Flange bracket options B1 Bracket for 2-in. pipe mounting  For use with the traditional flange option  Bracket for mounting on 2-in. pipe  CS construction with CS bolts  Coated with polyurethane paint B2 Bracket for panel mounting  For use with the traditional flange option  Bracket for mounting transmitter on wall or panel  CS construction with CS bolts  Coated with polyurethane paint B3 Flat Bracket for 2-in. pipe mounting  For use with the traditional flange option

Emerson.com/Rosemount

129

Rosemount 3051
 Bracket for vertical mounting of transmitter on 2-in. pipe  CS construction with CS bolts  Coated with polyurethane paint B7 B1 Bracket with SST bolts  Same bracket as the B1 option with Series 300 SST bolts B8 B2 Bracket with SST bolts  Same bracket as the B2 option with Series 300 SST bolts B9 B3 Bracket with SST bolts  Same bracket as the B3 option with Series 300 SST bolts BA SST B1 bracket with SST bolts  B1 bracket in SST with Series 300 SST bolts BC SST B3 Bracket with SST bolts  B3 bracket in SST with Series 300 SST bolts

April 2021

130

Emerson.com/Rosemount

April 2021

Rosemount 3051

Emerson.com/Rosemount

131

00813-0100-4001 Rev. WB
April 2021
For more information: www.emerson.com ©2021 Emerson. All rights reserved. Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.


Antenna House PDF Output Library 6.5.1231 (Windows (x64))