Operating manual - SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6.0

Operating manual

SB6.0-1AV-41;, SB5.0-1AV-41;, SB4.0-1AV-41;, SB3.6-1AV-41;, SB3.0-1AV-41

SMA Solar Technology AG

Operating manual - SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6

2 SBxx-1AV-41-BE-en-10 Operating manual Legal Provisions The information contained in these documents is the property of SMA Solar Technology AG. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without the prior

Operating manual - Beyond Solar

Operating manual. SBxx-1AV-41-BE-en-10. 2. Legal Provisions. The information contained in these documents is the property of SMA Solar Technology AG. No.

sunny boy 3.0-6.0-1AV-41 manual
Operating manual SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6.0

SUNNY BOY

ENGLISH

SBxx-1AV-41-BE-en-10 | Version 1.0

Legal Provisions

SMA Solar Technology AG

Legal Provisions
The information contained in these documents is the property of SMA Solar Technology AG. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA Solar Technology AG. Internal reproduction used solely for the purpose of product evaluation or other proper use is allowed and does not require prior approval. SMA Solar Technology AG makes no representations or warranties, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such representations or warranties are expressly disclaimed. Neither SMA Solar Technology AG nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances. The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply. Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Readers are cautioned, however, that product improvements and field usage experience may cause SMA Solar Technology AG to make changes to these specifications without advance notice, or per contract provisions in those cases where a supply agreement requires advance notice. SMA Solar Technology AG shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material.
SMA Warranty
You can download the current warranty conditions from the Internet at www.SMA-Solar.com.
Software licenses
The licenses for the used software modules can be called up on the user interface of the product.
Trademarks
All trademarks are recognized, even if not explicitly identified as such. Missing designations do not mean that a product or brand is not a registered trademark.
SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522-0 Fax +49 561 9522-100 www.SMA.de Email: info@SMA.de Status: 12/5/2018 Copyright © 2018 SMA Solar Technology AG. All rights reserved.

2

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

Table of Contents

Table of Contents

1 Information on this Document................................................. 6
1.1 Validity ........................................................................................................................ 6 1.2 Target Group.............................................................................................................. 6 1.3 Content and Structure of this Document ................................................................... 6 1.4 Levels of warning messages ...................................................................................... 6 1.5 Symbols in the Document .......................................................................................... 7 1.6 Typographies in the document .................................................................................. 7 1.7 Designation in the document ..................................................................................... 7

2 Safety ........................................................................................ 8
2.1 Intended Use .............................................................................................................. 8 2.2 IMPORTANT SAFETY INSTRUCTIONS.................................................................... 8

3 Scope of Delivery ..................................................................... 11

4 Product Overview .................................................................... 12
4.1 Product Description .................................................................................................... 12 4.2 Symbols on the Product ............................................................................................. 13 4.3 Interfaces and Functions ............................................................................................ 14 4.4 LED Signals ................................................................................................................. 16

5 Mounting................................................................................... 18
5.1 Requirements for Mounting ....................................................................................... 18 5.2 Mounting the Inverter................................................................................................. 20

6 Electrical Connection ................................................................ 22

6.1 Overview of the Connection Area ............................................................................ 22

6.2 AC Connection........................................................................................................... 22

6.2.1 Requirements for the AC Connection .................................................... 22 6.2.2 Connecting the Inverter to the Utility Grid ............................................ 24 6.2.3 Connecting Additional Grounding ........................................................ 25 6.3 Connecting the Network Cables............................................................................... 26

6.4 Connecting RS485 Devices....................................................................................... 28

6.5 Mounting the WLAN Antenna .................................................................................. 29

6.6 DC Connection........................................................................................................... 29

6.6.1 6.6.2 6.6.3 6.6.4

Requirements for the DC Connection .................................................... 29 Assembling the DC Connectors ............................................................. 31 Connecting the PV Array........................................................................ 33 Disassembling the DC Connectors ........................................................ 35

Operating manual

SBxx-1AV-41-BE-en-10

3

Table of Contents

SMA Solar Technology AG

7 Commissioning ......................................................................... 38
7.1 Commissioning Procedure ......................................................................................... 38 7.2 Commissioning the Inverter........................................................................................ 38 7.3 Selecting a configuration option ............................................................................... 40 7.4 Starting the Self-Test (for Italy and Dubai)................................................................ 42
8 Operation ................................................................................. 44
8.1 Establishing a connection to the user interface ........................................................ 44 8.1.1 Establishing a Direct Connection via Ethernet ...................................... 44 8.1.2 Establishing a direct connection via WLAN ......................................... 44 8.1.3 Establishing a Connection via Ethernet in the local network ............... 46 8.1.4 Establishing a Connection via WLAN in the Local Network ............... 47
8.2 Logging In and Out of the User Interface................................................................. 48 8.3 Start Page Design of the User Interface.................................................................... 49 8.4 Activating the Smart Inverter Screen......................................................................... 51 8.5 Starting the Installation Assistant ............................................................................... 52 8.6 Activate WPS Function............................................................................................... 53 8.7 Switching WLAN On and Off................................................................................... 53 8.8 Switching the Dynamic Power Display Off............................................................... 54 8.9 Changing the Password............................................................................................. 55 8.10 Changing Operating Parameters.............................................................................. 55 8.11 Configuring the Country Data Set............................................................................. 56 8.12 Configuring Feed-In Management............................................................................ 56 8.13 Configuring the Modbus Function............................................................................. 58 8.14 Activating the Receipt of Control Signals (Only for Italy)........................................ 58 8.15 Deactivating Grounding Conductor Monitoring...................................................... 59 8.16 Saving the Configuration in a File............................................................................. 59 8.17 Adopting a Configuration from a File....................................................................... 59 8.18 Updating the Firmware .............................................................................................. 60
9 Disconnecting the Inverter from Voltage Sources ................. 61
10 Cleaning the Inverter ............................................................... 63
11 Troubleshooting........................................................................ 64
11.1 Forgotten Password.................................................................................................... 64 11.2 Event Messages ......................................................................................................... 65 11.3 Checking the PV System for Ground Faults.............................................................. 81
12 Decommissioning the Inverter................................................. 85
13 Technical Data .......................................................................... 88

4

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

Table of Contents

13.1 DC/AC ....................................................................................................................... 88 13.1.1 Sunny Boy 3.0 / 3.6 / 4.0.................................................................... 88 13.1.2 Sunny Boy 5.0 / 6.0.............................................................................. 90
13.2 Climatic Conditions .................................................................................................... 92 13.3 Protective Devices ...................................................................................................... 92 13.4 Equipment ................................................................................................................... 93 13.5 Torques ....................................................................................................................... 93 13.6 Data Storage Capacity.............................................................................................. 93
14 Contact ...................................................................................... 94
15 EU Declaration of Conformity ................................................. 96

Operating manual

SBxx-1AV-41-BE-en-10

5

1 Information on this Document

SMA Solar Technology AG

1 Information on this Document
1.1 Validity
This document is valid for: · SB3.0-1AV-41 (Sunny Boy 3.0) · SB3.6-1AV-41 (Sunny Boy 3.6) · SB4.0-1AV-41 (Sunny Boy 4.0) · SB5.0-1AV-41 (Sunny Boy 5.0) · SB6.0-1AV-41 (Sunny Boy 6.0)
1.2 Target Group
This document is intended for qualified persons and end users. Only qualified persons are allowed to perform the activities marked in this document with a warning symbol and the caption "Qualified person". Tasks that do not require any particular qualification are not marked and can also be performed by end users. Qualified persons must have the following skills:
· Knowledge of how an inverter works and is operated · Training in how to deal with the dangers and risks associated with installing, repairing and
using electrical devices and installations · Training in the installation and commissioning of electrical devices and installations · Knowledge of all applicable laws, standards and directives · Knowledge of and compliance with this document and all safety information
1.3 Content and Structure of this Document
This document describes the mounting, installation, commissioning, configuration, operation, troubleshooting and decommissioning of the product as well as the operation of the product user interface. You will find the latest version of this document and further information on the product in PDF format and as eManual at www.SMA-Solar.com. You can also call up the eManual via the user interface of the product. Illustrations in this document are reduced to the essential information and may deviate from the real product.
1.4 Levels of warning messages
The following levels of warning messages may occur when handling the product.
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

6

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

1 Information on this Document

CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which, if not avoided, can result in property damage.

1.5 Symbols in the Document

Symbol


Explanation Information that is important for a specific topic or goal, but is not safety-relevant
Indicates a requirement for meeting a specific goal



Desired result



A problem that might occur

Example

Sections describing activities to be performed by qualified persons only

1.6 Typographies in the document

Typography bold
> [Button] [Key]

Use

Example

· Messages · Terminals · Elements on a user interface · Elements to be selected · Elements to be entered

· Connect the insulated conductors to the terminals X703:1 to X703:6.
· Enter 10 in the field Minutes.

· Connects several elements to be · Select Settings > Date. selected

· Button or key to be selected or pressed

· Select [Enter].

1.7 Designation in the document

Complete designation Sunny Boy

Designation in this document Inverter, product

Operating manual

SBxx-1AV-41-BE-en-10

7

2 Safety

SMA Solar Technology AG

2 Safety
2.1 Intended Use
The Sunny Boy is a transformerless PV inverter with two MPP trackers which converts the direct current of the PV array to grid-compliant alternating current and feeds it into the utility grid. The product is suitable for indoor and outdoor use. The product must only be operated with PV modules of protection class II in accordance with IEC 61730, application class A. The PV modules must be compatible with this product. The product is not equipped with a transformer and therefore has no galvanic isolation. The product must not be operated with PV modules whose outputs are grounded. This can cause the product to be destroyed. The product may be operated with PV modules whose frame is grounded. PV modules with a high capacity to ground must only be used if their coupling capacity does not exceed 1.4 F (for information on how to calculate the coupling capacity, see the Technical Information "Leading Leakage Currents" at www.SMA-Solar.com). All components must remain within their permitted operating ranges and their installation requirements at all times. The product must only be used in countries for which it is approved or released by SMA Solar Technology AG and the grid operator. Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable laws, regulations, standards and directives. Any other application may cause personal injury or property damage. Alterations to the product, e.g. changes or modifications, are only permitted with the express written permission of SMA Solar Technology AG. Unauthorized alterations will void guarantee and warranty claims and in most cases terminate the operating license. SMA Solar Technology AG shall not be held liable for any damage caused by such changes. Any use of the product other than that described in the Intended Use section does not qualify as the intended use. The enclosed documentation is an integral part of this product. Keep the documentation in a convenient, dry place for future reference and observe all instructions contained therein. This document does not replace and is not intended to replace any local, state, provincial, federal or national laws, regulations or codes applicable to the installation, electrical safety and use of the product. SMA Solar Technology AG assumes no responsibility for the compliance or noncompliance with such laws or codes in connection with the installation of the product. The type label must remain permanently attached to the product.
2.2 IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS This section contains safety information that must be observed at all times when working on or with the product.

8

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

2 Safety

The product has been designed and tested in accordance with international safety requirements. As with all electrical or electronical devices, there are residual risks despite careful construction. To prevent personal injury and property damage and to ensure long-term operation of the product, read this section carefully and observe all safety information at all times.
DANGER
Danger to life due to electric shock when live components or DC cables are touched
When exposed to sunlight, the PV modules generate high DC voltage which is present in the DC cables. Touching live DC cables results in death or lethal injuries due to electric shock.
· Disconnect the product from voltage sources and make sure it cannot be reconnected before working on the device.
· Do not touch non-insulated parts or cables. · Wear suitable personal protective equipment for all work on the product.
DANGER
Danger to life due to electric shock from touching an ungrounded PV module or array frame
Touching ungrounded PV modules or array frames results in death or lethal injuries due to electric shock.
· Connect and ground the frame of the PV modules, the array frame and the electrically conductive surfaces so that there is continuous conduction. Observe the applicable local regulations.
DANGER
Danger to life due to electric shock when touching live system components in case of a ground fault
If a ground fault occurs, parts of the system may still be live. Touching live parts and cables results in death or lethal injuries due to electric shock.
· Disconnect the product from voltage sources and make sure it cannot be reconnected before working on the device.
· Touch the cables of the PV array on the insulation only. · Do not touch any parts of the substructure or frame of the PV array. · Do not connect PV strings with ground faults to the inverter.
CAUTION
Risk of burns due to hot enclosure parts
Some parts of the enclosure can get hot during operation. · During operation, do not touch any parts other than the enclosure lid of the inverter.

Operating manual

SBxx-1AV-41-BE-en-10

9

2 Safety

SMA Solar Technology AG

CAUTION
Risk of injury due to weight of product
Injuries may result if the product is lifted incorrectly or dropped while being transported or when attaching it to or removing it from the wall mounting bracket.
· Transport and lift the product carefully. Take the weight of the product into account. · Wear suitable personal protective equipment for all work on the product.
NOTICE
Damage due to cleaning agents
The use of cleaning agents may cause damage to the product and its components. · Clean the product and all its components only with a cloth moistened with clear water.

10

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

3 Scope of Delivery

3 Scope of Delivery
Check the scope of delivery for completeness and any externally visible damage. Contact your distributor if the scope of delivery is incomplete or damaged.

A

B

C

D

E

F

_ +

G

H

I

J

Figure 1: Components included in the scope of delivery

Position A B C D E F G H
I J

Quantity 1 1 3 4 4 8 1 1
1 1

Designation Inverter
Wall mounting bracket
Pan head screw M5x12
Positive DC connector
Negative DC connector
Sealing plug
AC connector
RJ45 protective sleeve: swivel nut, cable support sleeve, threaded sleeve
WLAN antenna
Quick reference guide with password label on the rear side The label contains the following information:
· PIC (Product Identification Code) identification key for registering the system in Sunny Portal
· RID (Registration Identifier) registration ID for registering the system in Sunny Portal
· WLAN password WPA2-PSK (WiFi Protected Access 2 Preshared Key) for direct connection to the inverter via WLAN

Operating manual

SBxx-1AV-41-BE-en-10

11

4 Product Overview
4 Product Overview
4.1 Product Description

SMA Solar Technology AG

C

SUNNY BOY

A

B

Figure 2: Design of the Product

Position A B
C

Designation
DC load-break switch
LEDs The LEDs indicate the operating state of the inverter.
Type label The type label clearly identifies the product. The type label must remain permanently attached to the product. You will find the following information on the type label:
· Device type (Model) · Serial number (Serial No. or S/N) · Date of manufacture · Identification key (PIC) for registration in Sunny Portal · Registration ID (RID) for registration in Sunny Portal · WLAN password (WPA2-PSK) for the direct connection to the user
interface of the inverter via WLAN · Device-specific characteristics

12

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

4 Product Overview

4.2 Symbols on the Product

Symbol

Explanation
Beware of a danger zone This symbol indicates that the product must be additionally grounded if additional grounding or equipotential bonding is required at the installation site.

Beware of electrical voltage The product operates at high voltages.

Beware of hot surface The product can get hot during operation.

Danger to life due to high voltages in the inverter; observe a waiting time of 5
5 min
minutes High voltages that can cause lethal electric shocks are present in the live components of the inverter. Prior to performing any work on the inverter, disconnect it from all voltage sources as described in this document.
Observe the documentation Observe all documentation supplied with the product.

Observe the documentation Together with the red LED, this symbol indicates an error. Inverter Together with the green LED, this symbol indicates the operating state of the inverter. Data transmission Together with the blue LED, this symbol indicates the status of the network connection. Grounding conductor This symbol indicates the position for connecting a grounding conductor.
Alternating current
Direct current

Operating manual

SBxx-1AV-41-BE-en-10

13

4 Product Overview

Symbol

Explanation The product is has no galvanic isolation.

SMA Solar Technology AG

WEEE designation Do not dispose of the product together with the household waste but in accordance with the disposal regulations for electronic waste applicable at the installation site.
The product is suitable for outdoor installation.

03931-16-03337

Degree of protection IP65 The product is protected against the penetration of dust and water that is directed as a jet against the enclosure from all directions.
CE marking The product complies with the requirements of the applicable EU directives.
RCM (Regulatory Compliance Mark) The product complies with the requirements of the applicable Australian standards.
ICASA The product complies with the requirements of the South African standards for telecommunication.
ANATEL The product complies with the requirements of the Brazilian standards for telecommunication. Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.

4.3 Interfaces and Functions
The inverter is equipped with the following interfaces and functions:
User interface for monitoring and configuration
The product is equipped as standard with an integrated webserver, which provides a user interface for configuring and monitoring the product. The product user interface can be called up via the web browser if there is an existing connection to an end device (e.g. computer, tablet PC or smartphone).

14

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

4 Product Overview

Smart Inverter Screen
The Smart Inverter Screen enables you to view the status display and to display the current power and consumption on the user interface login page. You therefore have an overview of the most important inverter data without having to log into the user interface. The Smart Inverter Screen is deactivated by default. The Smart Inverter Screen can be activated via the user interface once the inverter has been commissioned.
SMA Speedwire
The product is equipped with SMA Speedwire as standard. SMA Speedwire is a type of communication based on the Ethernet standard. SMA Speedwire is designed for a data transfer rate of 100 Mbps and enables optimum communication between Speedwire devices within systems.
SMA Webconnect
The inverter is equipped with a Webconnect function as standard. The Webconnect function enables direct data transmission between the inverters and Internet portals Sunny Portal and Sunny Places without any additional communication device and for a maximum of 4 inverters per visualized system. In PV systems with more than 4 inverters, there is the option of establishing data transmission between the inverters and Sunny Portal via the data logger (e.g., SMA Data Manager) or distributing the inverters over several systems. If there is an existing WLAN or Ethernet connection, you can directly access your visualized system via the web browser on your end device. Webconnect enables - for PV systems operated in Italy - the connection or disconnection of the inverter to or from the utility grid and the specifying of the frequency limits to be used via IEC61850-GOOSE messages.
WLAN
The product is equipped with a WLAN interface as standard. The inverter is delivered with the WLAN interface activated as standard. If you do not want to use WLAN, you can deactivate the WLAN interface. In addition, the product has a WPS function. The WPS function is for automatically connecting the product to a network (e.g. via router) and establish a direct connection between the product and an end device.
Modbus
The product is equipped with a Modbus interface. The Modbus interface is deactivated by default and must be configured as needed. The Modbus interface of the supported SMA products is designed for industrial use ­ via SCADA systems, for example ­ and has the following tasks:
· Remote query of measured values · Remote setting of operating parameters · Setpoint specifications for system control
Grid management services
The product is equipped with service functions for grid management.

Operating manual

SBxx-1AV-41-BE-en-10

15

4 Product Overview

SMA Solar Technology AG

Depending on the requirements of the grid operator, you can activate and configure the functions (e.g. active power limitation) via operating parameters.
Parallel Operation of the DC Inputs A and B
You have the option of operating the inverter DC inputs A and B in parallel. As a result, and as opposed to normal operation, several parallel-connected strings can be connected to the inverter. The inverter automatically detects the parallel operation of the DC inputs A and B.
SMA OptiTrac Global Peak
SMA OptiTrac Global Peak is an advancement of SMA OptiTrac and allows the operating point of the inverter to follow the optimal operating point of the PV array (MPP) precisely at all times. In addition, with the aid of SMA OptiTrac Global Peak, the inverter detects several maximum power points in the available operating range, such as may occur particularly with partially shaded strings. SMA OptiTrac Global Peak is enabled by default.
All-pole sensitive residual-current monitoring unit
The all-pole sensitive residual-current monitoring unit detects alternating and direct differential currents. In single-phase and three-phase inverters, the integrated differential current sensor detects the current difference between the neutral conductor and the line conductor(s). If the current difference increases suddenly, the inverter disconnects from the utility grid.
SMA Smart Connected
SMA Smart Connected is the free monitoring of the inverter via the SMA Sunny Portal. Thanks to SMA Smart Connected, the PV system operator and qualified person will be informed automatically and proactively about inverter events that occur. SMA Smart Connected is activated during registration in Sunny Portal. In order to use SMA Smart Connected, it is necessary that the inverter is permanently connected to Sunny Portal and the data of the PV system operator and qualified person is stored in Sunny Portal and up-to-date.

4.4 LED Signals
The LEDs indicate the operating state of the inverter.

LED signal

Explanation

The green LED is flashing (two seconds on and two seconds off)

Waiting for feed-in conditions
The conditions for feed-in operation are not yet met. As soon as the conditions are met, the inverter will start feed-in operation.

The green LED flashes quickly

Update of central processing unit The central processing unit of the inverter is being updated.

The green LED is glowing Feed-in operation The inverter feeds in with a power of at least 90%.

16

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

4 Product Overview

LED signal

Explanation

The green LED is pulsing

Feed-in operation
The inverter is equipped with a dynamic power display via the green LED. Depending on the power, the green LED pulses fast or slow. If necessary, you can switch off the dynamic power display via the green LED.

The green LED is off

The inverter is not feeding into the utility grid.

The red LED is glowing

Event occurred
If an event occurs, a distinct event message and the corresponding event number will be displayed in addition on the inverter user interface or in the communication product.

The blue LED flashes slowly for approx. one minute

Communication connection is being established
The inverter is establishing a connection to a local network or is establishing a direct connection to an end device via Ethernet (e.g. computer, tablet PC or smartphone).

The blue LED flashes quickly WPS active for approx. two minutes. The WPS function is active.

The blue LED is glowing

Communication active
There is an active connection with a local network or there is a direct connection with an end device via Ethernet (e.g. computer, tablet PC or smartphone).

Operating manual

SBxx-1AV-41-BE-en-10

17

5 Mounting

SMA Solar Technology AG

5 Mounting
5.1 Requirements for Mounting
Requirements for the Mounting Location:
WARNING
Danger to life due to fire or explosion
Despite careful construction, electrical devices can cause fires. · Do not mount the product in areas containing highly flammable materials or gases. · Do not mount the product in potentially explosive atmospheres.
 A solid support surface must be available (e.g., concrete or masonry). When mounted on drywall or similar materials, the product emits audible vibrations during operation which could be perceived as annoying.
 The mounting location must be inaccessible to children.  The mounting location must be suitable for the weight and dimensions of the product (see
Section 13 "Technical Data", page 88).  The mounting location must not be exposed to direct solar irradiation. If the product is
exposed to direct solar irradiation, the exterior plastic parts might age prematurely and overheating might occur. When becoming too hot, the product reduces its power output to avoid overheating.  The mounting location should be freely and safely accessible at all times without the need for any auxiliary equipment (such as scaffolding or lifting platforms). Non-fulfillment of these criteria may restrict servicing.  The DC load-break switch of the product must always be freely accessible.  All ambient conditions must be met (see Section 13, page 88).  To ensure optimum operation, the ambient temperature should be between -25°C and +40°C.
Permitted and prohibited mounting positions:  The product may only be mounted in a permitted position. This will ensure that no moisture can penetrate the product.  The product should be mounted such that the LED signals can be read off without difficulty.
15°

Figure 3: Permitted and prohibited mounting positions

18

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
Dimensions for mounting: 217.5 156.5 121 93

217.5 156.5 126.5 107.5

5 Mounting

172

90 120 30
150

470

9 x 18 Ø 9

9 x 18

UP

9 x 18

298

315
435
Figure 4: Position of the anchoring points(Dimensions in mm)
Recommended Clearances: If you maintain the recommended clearances, adequate heat dissipation will be ensured. Thus, you will prevent power reduction due to excessive temperature.
 Maintain the recommended clearances to walls as well as to other inverters or objects.  If multiple inverters are mounted in areas with high ambient temperatures, increase the
clearances between the inverters and ensure sufficient fresh-air supply.

Operating manual

SBxx-1AV-41-BE-en-10

19

5 Mounting

SMA Solar Technology AG

450

450

150

210

270

210

100

430

430

Figure 5: Recommended clearances(Dimensions in mm)
5.2 Mounting the Inverter

Additionally required mounting material (not included in the scope of delivery):  3 screws, suitable for the support surface and the weight of the inverter (diameter: minimum 6 mm)  3 washers, suitable for the screws (outer diameter: minimum 18 mm)  Where necessary, 3 screw anchors suitable for the support surface and the screws
CAUTION
Risk of injury due to weight of product
Injuries may result if the product is lifted incorrectly or dropped while being transported or when attaching it to or removing it from the wall mounting bracket.
· Transport and lift the product carefully. Take the weight of the product into account. · Wear suitable personal protective equipment for all work on the product.

Procedure:

1.

CAUTION

Risk of injury due to damaged cables
There may be power cables or other supply lines (e.g. gas or water) routed in the wall. · Ensure that no lines are laid in the wall which could be damaged when drilling holes.

20

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

5 Mounting

2. Align the wall mounting bracket horizontally on the

wall and mark the position of the drill holes. Use at

least one hole on the right- and left-hand side and

the lower hole in the middle of the wall mounting

UP

bracket. Tip: When mounting on a post, use the

upper and lower central holes of the wall mounting

bracket.

3. Set the wall mounting bracket aside and drill the marked holes. 4. Insert screw anchors into the drill holes if the support surface requires them. 5. Secure the wall mounting bracket horizontally using
screws and washers.

UP

6. Hook the inverter into the wall mounting bracket. When doing so, the two right- and left-hand keys on the ribs on the rear side of the inverter must be hooked into the respective right-hand and left-hand keyways in the wall mounting bracket.
UP
7. Ensure that the inverter is securely in place. 8. Secure the inverter to the wall mounting bracket. To
do so, insert one pan head screw M5x12 each into the lower screw hole on both sides of the inverter anchorage bracket respectively and tighten them using a Torx screwdriver (TX 25, torque: 2.5 Nm).

Operating manual

SBxx-1AV-41-BE-en-10

21

6 Electrical Connection

6 Electrical Connection

6.1 Overview of the Connection Area

+ A -

+ B - RS485

AC

SMA Solar Technology AG

A B C DE Figure 6: Connection areas at the bottom of the inverter

FG

Position A B C D E F G

Designation 2 positive and 2 negative DC connectors, input A 2 positive and 2 negative DC connectors, input B Jack with protective cap for RS485 communication connection Network port with protective cap Jack with protective cap for the WLAN antenna Jack for the AC connection Connection point for an additional grounding

6.2 AC Connection

6.2.1 Requirements for the AC Connection
Cable requirements:  External diameter: 10 mm to 14 mm  Conductor cross-section: 2.5 mm² to 6 mm²  Insulation stripping length: 12 mm  Sheath stripping length: 50 mm  The cable must be dimensioned in accordance with the local and national directives for the dimensioning of cables. The requirements for the minimum wire size derive from these directives. Examples of factors influencing cable dimensioning are: nominal AC current, type of cable, routing method, cable bundling, ambient temperature and maximum desired line losses (for calculation of line losses, see the design software "Sunny Design" from software version 2.0 at www.SMA-Solar.com).

22

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

6 Electrical Connection

Load-break switch and cable protection:
NOTICE
Damage to the inverter due to the use of screw-type fuses as load-break switches
Screw-type fuses (e.g. DIAZED fuse or NEOZED fuse) are not load-break switches. · Do not use screw-type fuses as load-break switches. · Use a load-break switch or circuit breaker as a load disconnection unit (for information and design examples, see the Technical Information "Circuit Breaker" at www.SMA-Solar.com).
 In PV systems with multiple inverters, protect each inverter with a separate circuit breaker. Make sure to observe the maximum permissible fuse protection (see Section 13 "Technical Data", page 88). This will prevent residual voltage from being present at the corresponding cable after disconnection.
 Loads installed between the inverter and the circuit breaker must be fused separately.
Residual-current monitoring unit:  If an external residual-current device is required, install a residual-current device which trips at a residual current of 100 mA or higher (for details on selecting a residual-current device, see the Technical Information "Criteria for Selecting a Residual-Current Device" at www.SMASolar.com).
Overvoltage category: The inverter can be used in grids of overvoltage category III or lower in accordance with IEC 60664-1. That means that the inverter can be permanently connected to the grid-connection point of a building. In case of installations with long outdoor cabling routes, additional measures to reduce overvoltage category IV to overvoltage category III are required (see the Technical Information "Overvoltage Protection" at www.SMA-Solar.com).
Grounding conductor monitoring: The inverter is equipped with a grounding conductor monitoring device. This grounding conductor monitoring device detects when there is no grounding conductor connected and disconnects the inverter from the utility grid if this is the case. Depending on the installation site and grid configuration, it may be advisable to deactivate the grounding conductor monitoring. This is necessary, for example, in an IT system if there is no neutral conductor present and you intend to install the inverter between two line conductors. If you are uncertain about this, contact your grid operator or SMA Solar Technology AG.
· Grounding conductor monitoring must be deactivated after initial start-up depending on the grid configuration (see Section 8.15, page 59).

Operating manual

SBxx-1AV-41-BE-en-10

23

6 Electrical Connection

SMA Solar Technology AG

Safety in accordance with IEC 62109 when the grounding conductor monitoring is deactivated
In order to guarantee safety in accordance with IEC 62109 when the grounding conductor monitoring is deactivated, you have to connect an additional grounding conductor to the inverter.
· Connect an additional grounding conductor that has an cross-section of at least 10 mm (see Section 6.2.3, page 25). This prevents touch current in the event of the grounding conductor on the AC connector bush insert failing.
Connection of an additional grounding conductor
In some countries, an additional grounding conductor is generally required. In each case, observe the locally applicable regulations.
· If an additional grounding conductor is required, connect the one that has an crosssection of at least 10 mm (see Section 6.2.3, page 25). This prevents touch current in the event of the grounding conductor on the AC connector bush insert failing.
6.2.2 Connecting the Inverter to the Utility Grid

Requirements:  The AC and DC electric circuits are isolated from the enclosure. If required by the National Electrical Code® ANSI/NFPA 70 or Canadian Electrical Code® CSA C22.1, the installer is responsible for grounding the system.  The connection requirements of the grid operator must be met.  The grid voltage must be within the permissible range. The exact operating range of the inverter is specified in the operating parameters.
Procedure: 1. Disconnect the circuit breaker and secure it against reconnection. 2. Dismantle the AC cable by 50 mm. 3. Shorten L1, L2, L3 and N by 8 mm each so that the grounding conductor is 8 mm longer. This ensures that the grounding conductor is the last to be pulled from the screw terminal in the event of tensile strain. 4. Strip the insulation of L1, L2, L3, N and the grounding conductor by 12 mm. 5. In the case of fine stranded wire, L1, L2, L3, N and the grounding conductor are to be fitted with bootlace ferrules. 6. Assemble the AC connector and connect the conductor to the AC connector (see manual of the AC connector). 7. Ensure that all conductors are securely connected to the AC connector.

24

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
8. Plug the AC connector into the jack for the AC connection. When doing so, align the AC connector so that the key on the inverter AC jack is inserted into the keyway on the AC connector bush insert.

6 Electrical Connection

6.2.3 Connecting Additional Grounding
If additional grounding or equipotential bonding is required locally, you can connect additional grounding to the inverter. This prevents touch current if the grounding conductor on the AC connector fails. The necessary ring terminal lug and the screw are included in the scope of delivery of the inverter.
Additionally required material (not included in the scope of delivery):  1 grounding cable
Cable requirements:
Use of fine-stranded conductors
You can use an inflexible or a flexible, fine-stranded conductor. · When using a fine-stranded conductor, it has to be double crimped by a ring terminal lug. Make sure that no insulated conductor is visible when pulling or bending. This will ensure sufficient strain relief by means of the ring terminal lug.
 Grounding cable cross-section: max. 10 mm²
Procedure: 1. Strip the grounding cable insulation. 2. Insert the stripped part of the grounding cable into the ring terminal lug and crimp using a crimping tool.

Operating manual

SBxx-1AV-41-BE-en-10

25

6 Electrical Connection
3. Insert the pan head screw M5x12 into the screw hole in the ring terminal lug and screw the ring terminal lug with screw firmly onto the connection point for additional grounding using a Torx screwdriver (TX 25, torque: 2.5 Nm).

SMA Solar Technology AG

6.3 Connecting the Network Cables
DANGER
Danger to life due to electric shock in case of overvoltages and if surge protection is missing
Overvoltages (e. g. in the event of a flash of lightning) can be further conducted into the building and to other connected devices in the same network via the network cables or other data cables if there is no surge protection. Touching live parts and cables results in death or lethal injuries due to electric shock.
· Ensure that all devices in the same network are integrated in the existing overvoltage protection.
· When laying the network cable outdoors, ensure that there is suitable surge protection at the network cable transition from the product outdoors to the network inside the building.
· The Ethernet interface of the inverter is classified as "TNV-1" and offers protection against overvoltages of up to 1.5 kV.
Additionally required material (not included in the scope of delivery):  1 network cable
Cable requirements: The cable length and quality affect the quality of the signal. Observe the following cable requirements.
 Cable type: 100BaseTx  Cable category: Cat5, Cat5e, Cat6, Cat6a or Cat7  Plug type: RJ45 of Cat5, Cat5e, Cat6 or Cat6a  Shielding: SF/UTP, S/UTP, SF/FTP or S/FTP  Number of insulated conductor pairs and insulated conductor cross-section: at least 2 x 2 x
0.22 mm²  Maximum cable length between two nodes when using patch cables: 50 m  Maximum cable length between two nodes when using installation cables: 100 m  UV-resistant for outdoor use

26

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

6 Electrical Connection

NOTICE
Damage to the inverter due to moisture ingress
Moisture penetration can damage the inverter and impair its functionality. · Connect the network cable with the supplied RJ45 protective sleeve to the inverter.

Procedure:

1.

DANGER

Danger to life due to electric shock
· Disconnect the inverter from all voltage sources (see Section 9, page 61).

2. Unscrew the protective cap from the network port.

3. Press the cable support sleeve out of the threaded sleeve.

4. Thread the swivel nut and threaded sleeve over the

network cable. At the same time, thread the network

cable through the opening in the cable support

sleeve.

1

2

5. Press the cable support sleeve into the threaded sleeve.

6. Plug the network cable connector into the network port on the inverter and screw the threaded sleeve onto the network port thread on the inverter.

2

1

3

7. Screw the swivel nut onto the threaded sleeve.
Operating manual

2 1

SBxx-1AV-41-BE-en-10

27

6 Electrical Connection

SMA Solar Technology AG

8. If you would like to establish a direct connection, connect the other end of the network cable directly to the end device.
9. If you would like to integrate the inverter into a local network, connect the other end of the network cable to the local network (e.g. via a router).
6.4 Connecting RS485 Devices

Additionally required material (not included in the scope of delivery):  One communication cable for RS485 communication  One M12 plug, 4-pole

Signal assignment: Pin connector

Signal

1

2

1

2

3

4

4

3

GND +12 V DataData+

TS4 Gateway
+ B A

Insulated conductor color

Procedure:

1.

DANGER

Danger to life due to electric shock
· Disconnect the inverter from all voltage sources (see Section 9, page 61).

2. Assemble the M12 plug and connect the RS485 cable to the plug (see manual of the M12 connector).

3. Ensure that all conductors are correctly connected to the M12 plug.

4. Unscrew the protective cap from the jack for the

RS485 communication connection.

RS485

28

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
5. Plug the M12 connector into the jack for the RS485 communication connection and screw tight. When doing so, align the connector so that the key on the inverter AC jack is inserted into the keyway on the plug.
6.5 Mounting the WLAN Antenna

6 Electrical Connection

2

RS485

1

Requirement:  The WLAN antenna supplied must be used.

Procedure:

1.

DANGER

Danger to life due to electric shock
· Disconnect the inverter from all voltage sources (see Section 9, page 61).

2. Remove the protective cap from the jack on the inverter.

3. Plug the WLAN antenna into the jack and screw

tight (torque: 1 Nm).

2

1
4. Pull on the WLAN antenna to ensure that the WLAN antenna is securely in place.
6.6 DC Connection
6.6.1 Requirements for the DC Connection
Connection options: The inverter has two DC inputs, to each of which one string can be connected in normal operation.

Operating manual

SBxx-1AV-41-BE-en-10

29

6 Electrical Connection

SMA Solar Technology AG

You have the option of operating the DC inputs A and B in parallel, and therefore of connecting several strings to the inverter.

+A-

+B-

+A- +B-

+_ +_ +_ +_

Figure 7: Connection overview for normal operation

+A- +B-

+A-

+B-

+_ +_ +_ +_ Figure 8: Connection overview for parallel connection of the DC inputs A and B

30

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

6 Electrical Connection

Requirements for the PV modules per input:  All PV modules should be of the same type.  All PV modules should be aligned and tilted identically.  On the coldest day based on statistical records, the open-circuit voltage of the PV array must never exceed the maximum input voltage of the inverter.  The same number of series-connected PV modules must be connected to each string.  The maximum input current per string must be maintained and must not exceed the throughfault current of the DC connectors (see Section 13 "Technical Data", page 88).  The thresholds for the input voltage and the input current of the inverter must be adhered to (see Section 13 "Technical Data", page 88).  The positive connection cables of the PV modules must be equipped with positive DC connectors (see Section 6.6.2, page 31).  The negative connection cables of the PV modules must be equipped with the negative DC connectors (see Section 6.6.2, page 31).
Use of Y adapters for parallel connection of strings
The Y adapters must not be used to interrupt the DC circuit. · Do not use the Y adapters in the immediate vicinity of the inverter. The adapters must not be visible or freely accessible. · In order to interrupt the DC circuit, always disconnect the inverter as described in this document (see Section 9, page 61).
6.6.2 Assembling the DC Connectors

For connection to the inverter, all PV module connection cables must be fitted with the DC connectors provided. Assemble the DC connectors as described in the following. The procedure is identical for both connectors (+ and -). The graphics for the procedure are shown for only the positive connector as an example. Pay attention to the correct polarity when assembling the DC connectors. The DC connectors are marked with the symbols "+" and "-".

Figure 9: Negative (A) and positive (B) DC connectors

Operating manual

SBxx-1AV-41-BE-en-10

31

6 Electrical Connection

SMA Solar Technology AG

Cable requirements:  Cable type: PV1-F, UL-ZKLA, USE2  External diameter: 5 mm to 8 mm  Conductor cross-section: 2.5 mm² to 6 mm²  Qty single wires: minimum 7  Nominal voltage: minimum 1000 V  Using bootlace ferrules is not allowed.
DANGER
Danger to life due to high voltages on the DC conductors
When exposed to sunlight, the PV array generates dangerous DC voltage which is present in the DC conductors. Touching the DC conductors can lead to lethal electric shocks.
· Ensure that the inverter is disconnected from all voltage sources. · Do not touch non-insulated cable ends. · Do not touch the DC conductors.
NOTICE
Destruction of the inverter due to overvoltage
If the open-circuit voltage of the PV modules exceeds the maximum input voltage of the inverter, the inverter can be destroyed due to overvoltage.
· If the open-circuit voltage of the PV modules exceeds the maximum input voltage of the inverter, do not connect any strings to the inverter and check the design of the PV system.
Procedure: 1. Strip 12 mm of the cable insulation. 2. Insert the stripped cable into the DC connector up to the stop. When doing so, ensure that the stripped cable and the DC connector are of the same polarity.
+

3. Press the clamping bracket down until it audibly snaps into place.

+

32

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
 The stranded wire can be seen inside the clamping bracket chamber.

6 Electrical Connection
+

4. If the stranded wire is not visible in the chamber, the cable is not correctly inserted and the connector must be reassembled. To do this, the cable must be removed from the connector.

· Release the clamping bracket. To do so, insert a screwdriver (blade width: 3.5 mm) into the clamping bracket and pry the clamping bracket open.

2 1

+

· Remove the cable and go back to step 2.

1
2
+

5. Push the swivel nut up to the thread and tighten (torque: 2 Nm).
6.6.3 Connecting the PV Array

NOTICE
Destruction of the inverter due to overvoltage
If the open-circuit voltage of the PV modules exceeds the maximum input voltage of the inverter, the inverter can be destroyed due to overvoltage.
· If the open-circuit voltage of the PV modules exceeds the maximum input voltage of the inverter, do not connect any strings to the inverter and check the design of the PV system.
NOTICE
Destruction of the measuring device due to overvoltage
· Only use measuring devices with a DC input voltage range of 1000 V or higher.

Operating manual

SBxx-1AV-41-BE-en-10

33

6 Electrical Connection

SMA Solar Technology AG

NOTICE
Damage to the DC connectors due to the use of contact cleaner of other cleaning agents
Some contact cleaners or other cleaning agents may contain substances that decompose the plastic of the DC connectors.
· Do not use contact cleaners or other cleaning agents for cleaning the DC connectors.
NOTICE
Damage to the inverter due to ground fault on DC side during operation
Due to the transformerless topology of the product, the occurance of ground faults on DC side during operation can lead to irreparable damage. Damages to the product due to a faulty or damaged DC installation are not covered by warranty. The product is equipped with a protective device that checks whether a ground fault is present during the starting sequence. The product is not protected during operation.
· Ensure that the DC installation is carried out correctly and no ground fault occurs during operation.
Procedure: 1. Ensure that the circuit breaker is switched off and that it cannot be reconnected. 2. If an external DC load-break switch is installed, disconnect the external DC load-break switch from all voltage sources. 3. Set the DC load-break switch of the inverter to position O.

4. Measure the PV array voltage. Ensure that the maximum input voltage of the inverter is adhered to and that there is no ground fault in the PV array.
5. Check whether the DC connectors have the correct polarity.
If the DC connector is equipped with a DC cable of the wrong polarity, the DC connector must be reassembled. The DC cable must always have the same polarity as the DC connector.
6. Ensure that the open-circuit voltage of the PV array does not exceed the maximum input voltage of the inverter.

34

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
7. Connect the assembled DC connectors to the inverter.

6 Electrical Connection

 The DC connectors snap into place. 8. Ensure that all DC connectors are securely in place.

9.

NOTICE

Damage to the product due to sand, dust and moisture ingress if the DC inputs are not closed
The product is only properly sealed when all unused DC inputs are closed with DC connectors and sealing plugs. Sand, dust and moisture penetration can damage the product and impair its functionality.
· Seal all unused DC inputs using the DC connectors and sealing plugs as described in the following. When doing so, do not plug the sealing plugs directly into the DC inputs on the inverter.

10. For unused DC connectors, push down the clamping bracket and push the swivel nut up to the thread.
11. Insert the sealing plug into the DC connector.

+
12. Insert the DC connectors with sealing plugs into the corresponding DC inputs on the inverter.  The DC connectors snap into place.
13. Ensure that the DC connectors with sealing plugs are securely in place.
6.6.4 Disassembling the DC Connectors
To disassemble the DC connectors (e.g. due to faulty assembly), proceed as follows.

Operating manual

SBxx-1AV-41-BE-en-10

35

6 Electrical Connection

SMA Solar Technology AG

DANGER
Danger to life due to electric shock when touching exposed DC conductors or DC plug contacts if the DC connectors are damaged or loose
The DC connectors can break or become damaged, become free of the DC cables, or no longer be connected correctly if the DC connectors are released and disconnected incorrectly. This can result in the DC conductors or DC plug contacts being exposed. Touching live DC conductors or DC plug connectors will result in death or serious injury due to electric shock.
· Wear insulated gloves and use insulated tools when working on the DC connectors. · Ensure that the DC connectors are in perfect condition and that none of the DC conductors
or DC plug contacts are exposed. · Carefully release and remove the DC connectors as described in the following.

Procedure:
1. Release and remove the DC connectors. To do so, insert a flat-blade screwdriver or an angled screwdriver (blade width: 3.5 mm) into one of the side slots and pull the DC connectors out. When doing so, do not lever the DC connectors out, but insert the tool into one of the side slots only to release the locking mechanism, and do not pull on the cable.
2. Remove the DC connector swivel nut.

2 1

+

3. Unlock the DC connector. To do this, insert a flat-

blade screwdriver (blade width: 3.5 mm) into the

3

side catch mechanism and pry the catch mechanism

open.

+

2

1 4. Carefully pull the DC connector apart.

36

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
5. Release the clamping bracket. To do so, insert a flatblade screwdriver (blade width: 3.5 mm) into the clamping bracket and pry the clamping bracket open.
6. Remove the cable.

6 Electrical Connection 2
1
+

Operating manual

SBxx-1AV-41-BE-en-10

37

7 Commissioning

SMA Solar Technology AG

7 Commissioning
7.1 Commissioning Procedure

This section describes the commissioning procedure and gives an overview of the steps you must perform in the prescribed order.

Procedure

See

1. Commission the inverter.

Section 7.2, page 38

2. Establish a connection to the user interface of the inverter. Section 8.1, page 44 There are various connection options to choose from for this: · Direct connection via WLAN · Direct connection via Ethernet · Connection via WLAN in the local network · Connection via Ethernet in the local network

3. Log into the user interface.

Section 8.2, page 48

4. Select the inverter configuration option. Please note that Section 7.3, page 40 the SMA Grid Guard code for changing the grid-relevant parameters must be available after completion of the first ten feed-in hours or installation assistant (see "Application for the SMA Grid Guard code" available at www.SMASolar.com).

5. Ensure that the country data set has been configured cor- Section 8.11, page 56 rectly.

6. For PV systems in Italy or Dubai: Start the self-test.

Section 7.4, page 42

7. Make further inverter settings as needed.

Section 8, page 44

7.2 Commissioning the Inverter

Requirements:  The AC circuit breaker must be correctly rated and mounted.  The inverter must be correctly mounted.  All cables must be correctly connected.
Procedure: 1. Switch on the AC circuit breaker.

38

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
2. Turn the DC load-break switch of the inverter to position I.

7 Commissioning

 All three LEDs light up. The start-up phase begins.
 All three LEDs go out again after approximately 90 seconds.
 The green LED starts to flash and, if the inverter is connected via Speedwire, the blue LED also starts to flash. If the green LED is still flashing after some time, the conditions for activating feed-in operation are not yet met. As soon as the conditions for feed-in operation are met, the inverter starts with feed-in operation and, depending on the available power, the green LED will light up continuously or it will pulse.
3. If th red LED is glowing, an error has occurred that must be rectified (see Section 11, page 64).

Operating manual

SBxx-1AV-41-BE-en-10

39

7 Commissioning

SMA Solar Technology AG

7.3 Selecting a configuration option

After you have logged onto the user interface as Installer, the Configuring the Inverter page opens.

A B
E

D

C

Figure 10: Layout of the Configuring the Inverter page

Position A

Designation Device information

B

User information

C

Skip configuration

D

Checkbox

E

Configuration options

Description
Provides the following information: · Device name · Inverter serial number · Inverter firmware version
Provides brief information on the listed configuration options
Offers the option of skipping the inverter configuration and go directly to the user interface (not recommended)
Allows you to choose not to have the displayed page displayed again when the user interface is called up again
Provides a selection of the various configuration options

Procedure:
On the Configuring the Inverter page, different configuration options are available to choose from. Select one of the options and proceed for the selected option as described below. SMA Solar Technology AG recommends carrying out the configuration with the installation assistant. This way, you ensure that all relevant parameters are set for optimal inverter operation.

40

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

7 Commissioning

· Adoption of configuration from a file · Configuration with the installation assistant (recommended) · Manual configuration
Accepting the settings
Saving the made settings is indicated by an hourglass symbol on the user interface. If the DC voltage is sufficient, the data is transferred directly to the inverter and accepted. If the DC voltage is too low (e. g. in the evening), the settings are saved, but they cannot be directly transferred to or accepted by the inverter. As long as the inverter has not yet received and accepted the settings, the hourglass symbol will continue to be displayed on the user interface. The settings will be accepted when there is sufficient DC voltage applied and the inverter restarts. As soon as the hourglass symbol appears on the user interface, the settings have been saved. The settings will not be lost. You can log off of the user interface and leave the system.
Adopting the Configuration from a File
You can adopt the inverter configuration from a file. To do this, there must be an inverter configuration saved to a file.
Procedure: 1. Select the configuration option Adopting configuration from a file. 2. Select [Browse...] and select the desired file. 3. Select [Import file].
Configuring the Installation Assistant (Recommended)

A

C

B

Figure 11: Layout of the installation assistant (example)

Position A

Designation Configuration steps

Description
Overview of the installation assistant steps. The number of steps depends on the type of device and the additionally installed modules. The current step is highlighted in blue.

Operating manual

SBxx-1AV-41-BE-en-10

41

7 Commissioning

SMA Solar Technology AG

Position B
C

Designation User information
Configuration field

Description Information about the current configuration step and the setting options of the configuration step.
You can make settings in this field.

Procedure: 1. Select the configuration option Configuration with Installation Assistant.  The installation assistant will open. 2. Follow the installation assistant steps and make the settings appropriate for your system. 3. For every setting made in a step, select [Save and next].  In the last step, all made settings are listed in a summary. 4. To save the settings to a file, select [Export a summary] and save the file on your computer, tablet PC or smartphone. 5. To export all parameters and their settings, select [Export all parameters]. This exports all parameters and their settings into an HTML file. 6. To correct settings you made, select [Back], navigate to the desired step, correct settings and select [Save and continue]. 7. Once all settings are correct, select [Next] in the summary.  The start page of the user interface opens.
Manual configuration
You can configure the inverter manually by setting the desired parameters.
Procedure: 1. Select the configuration option Manual Configuration.  The Device Parameters menu on the user interface will open and all available parameter groups of the inverter will be displayed. 2. Select [Edit parameters]. 3. Select the desired parameter group.  All available parameters of the parameter group will be displayed. 4. Set the desired parameters. 5. Select [Save all].  The inverter parameters are set.

7.4 Starting the Self-Test (for Italy and Dubai)

The self-test is only required for inverters that are to be commissioned in Italy or Dubai. The Italian standard CEI 0-21 and the DEWA (Dubai Electricity and Water Authority) stipulate that all inverters that feed into the utility grid are equipped with a self-test function. During the self-test, the inverter will consecutively check the reaction times for overvoltage, undervoltage, maximum frequency and minimum frequency.

42

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

7 Commissioning

The self-test changes the upper and lower disconnection values for each protective function on a linear basis for frequency monitoring and voltage monitoring. As soon as the measured value exceeds the permitted disconnection threshold, the inverter disconnects from the utility grid. In this way, the inverter determines the reaction time and checks itself. After the self-test has been completed, the inverter automatically switches back to feed-in operation, resets the original disconnection conditions and connects to the utility grid. The test takes approximately three minutes.
Requirements:  The country data set of the inverter must be set to CEI 0-21 internal or DEWA 2016 internal.
Procedure: 1. Select the menu Device Configuration. 2. Select [Settings]. 3. Select [Starting the Self-Test] in the subsequent context menu. 4. Follow the instructions appearing in the dialog and save the report of the self-test where necessary.

Operating manual

SBxx-1AV-41-BE-en-10

43

8 Operation

SMA Solar Technology AG

8 Operation
8.1 Establishing a connection to the user interface
8.1.1 Establishing a Direct Connection via Ethernet
Requirements:  The product must be commissioned.  An end device (e.g. computer) with an Ethernet interface must be available.  The product must be connected directly to the end device.  The respective latest version of one of the following web browsers must be installed: Chrome, Edge, Firefox, Internet Explorer or Safari.  The SMA Grid Guard code of the Installer must be available for the changing of grid-relevant settings after completion of the first ten feed-in hours or installation assistant (see "Application for SMA Grid Guard Code" at www.SMA-Solar.com).
IP address of the inverter
· Standard inverter IP address for direct connection via Ethernet: 169.254.12.3
Procedure: 1. Open the web browser of your device, enter the IP address 169.254.12.3 in the address line and press the enter key.
2. Web browser signals a security vulnerability
After the IP address has been confirmed by pressing the enter key, a message might appear indicating that the connection to the user interface of the inverter is not secure. SMA Solar Technology AG guarantees that calling up the user interface is secure.
· Continue loading the user interface.  The login page of the user interface opens.
8.1.2 Establishing a direct connection via WLAN
Requirements:  The product must be commissioned.  The respective latest version of one of the following web browsers must be installed: Chrome, Edge, Firefox, Internet Explorer or Safari.  JavaScript must be enabled in the web browser of the end device.  The SMA Grid Guard code of the Installer must be available for the changing of grid-relevant settings after completion of the first ten feed-in hours or installation assistant (see "Application for SMA Grid Guard Code" at www.SMA-Solar.com).

44

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

8 Operation

SSID, IP address and necessary passwords
· SSID in WLAN: SMA[serial number] (e.g. SMA0123456789) · Standard WLAN password (usable until completion of the configuration by means of the
installation assistant or prior to the end of the first ten feed-in hours): SMA12345 · Device-specific WLAN password (usable for initial configuration to completion of the first
ten feed-in hours): see WPA2-PSK on the type label of the inverter or on the back of the manual included in the delivery · Standard IP address for a direct connection via WLAN outside of a local network: 192.168.12.3
Importing and exporting files with end devices having an iOS operating system is not possible.
For technical reasons, importing and exporting files (e.g. importing an inverter configuration, saving the current inverter configuration or exporting events and parameters) is not possible with mobile end devices having an iOS operating system.
· Use an end device that does not have an iOS operating system for importing and exporting files.
The procedure can be different depending on the end devices. If the procedure described does not apply to your end device, establish the direct connection via WLAN as described in the manual of your end device.
Procedure: 1. If your end device has a WPS function: · Activate the WPS function on the inverter. To do this, tap on the enclosure lid of the inverter twice.  The blue LED flashes quickly for approx. two minutes. The WPS function is active during this time. · Activate the WPS on your end device.  The connection with your end device will be established automatically. It can take up to 20 seconds for this connection to be established. 2. If your end device has not a WPS function: · Search for WLAN networks with your end device. · Select the SSID of the inverter SMA[serial number] in the list with the found WLAN networks. · Enter the inverter WLAN password. Within the first ten feed-in hours and prior to completing the configuration by means of the installation assistant, you must use the standard WLAN password SMA12345. After the first ten feed-in hours or after completing the configuration by means of the installation assistant, you must use the device-specific WLAN password (WPA2-PSK) of the inverter. You find the WLAN password (WPA2-PSK) on the type label. 3. Enter the IP address 192.168.12.3 or, if your device supports mDNS services, SMA[serial number].local or https://SMA[serial number] in the address bar of the web browser and press the enter key.

Operating manual

SBxx-1AV-41-BE-en-10

45

8 Operation

SMA Solar Technology AG

4. Web browser signals a security vulnerability
After the IP address has been confirmed by pressing the enter key, a message might appear indicating that the connection to the user interface of the inverter is not secure. SMA Solar Technology AG guarantees that calling up the user interface is secure.
· Continue loading the user interface.
 The login page of the user interface opens.
8.1.3 Establishing a Connection via Ethernet in the local network
New IP address for connecting with a local network
If the product is connected to a local network (e.g. via a router), the product will receive a new IP address. Depending on the type of configuration, the new IP address will be assigned automatically by the DHCP server (router) or manually by you. Upon completion of the configuration, the product can only be reached via the following access addresses:
· Generally applicable access address: IP address manually assigned or assigned by the DHCP server (router) (identification via network scanner software or network configuration of the router).
· Access address for Apple and Linux systems: SMA[serial number].local (e.g. SMA0123456789.local)
· Access address for Windows and Android systems: https://SMA[serial number] (e.g. http://SMA0123456789)
Requirements:  The product must be connected to the local network via a network cable (e.g. via a router).  The product must be integrated into the local network. Tip: There are various methods of integrating the product into the local network with the aid of the installation assistant.  An end device (e.g. computer, tablet PC or smartphone) must be available.  The end device must be in the same local network as the product.  The respective latest version of one of the following web browsers must be installed: Chrome, Edge, Firefox, Internet Explorer or Safari.  The SMA Grid Guard code of the Installer must be available for the changing of grid-relevant settings after completion of the first ten feed-in hours or installation assistant (see "Application for SMA Grid Guard Code" at www.SMA-Solar.com).
Procedure: 1. Open the web browser of your end device, enter the IP address of the inverter in the address line of the web browser and press the enter key.

46

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

8 Operation

2. Web browser signals a security vulnerability
After the IP address has been confirmed by pressing the enter key, a message might appear indicating that the connection to the user interface of the inverter is not secure. SMA Solar Technology AG guarantees that calling up the user interface is secure.
· Continue loading the user interface.
 The login page of the user interface opens.
8.1.4 Establishing a Connection via WLAN in the Local Network
New IP address for connecting with a local network
If the product is connected to a local network (e.g. via a router), the product will receive a new IP address. Depending on the type of configuration, the new IP address will be assigned automatically by the DHCP server (router) or manually by you. Upon completion of the configuration, the product can only be reached via the following access addresses:
· Generally applicable access address: IP address manually assigned or assigned by the DHCP server (router) (identification via network scanner software or network configuration of the router).
· Access address for Apple and Linux systems: SMA[serial number].local (e.g. SMA0123456789.local)
· Access address for Windows and Android systems: https://SMA[serial number] (e.g. http://SMA0123456789)
Requirements:  The product must be commissioned.  The product must be integrated into the local network. Tip: There are various methods of integrating the product into the local network with the aid of the installation assistant.  The end device must be in the same local network as the product.  The respective latest version of one of the following web browsers must be installed: Chrome, Edge, Firefox, Internet Explorer or Safari.  The SMA Grid Guard code of the Installer must be available for the changing of grid-relevant settings after completion of the first ten feed-in hours or installation assistant (see "Application for SMA Grid Guard Code" at www.SMA-Solar.com).
Importing and exporting files with end devices having an iOS operating system is not possible.
For technical reasons, importing and exporting files (e.g. importing an inverter configuration, saving the current inverter configuration or exporting events and parameters) is not possible with mobile end devices having an iOS operating system.
· Use an end device that does not have an iOS operating system for importing and exporting files.
Procedure: 1. Enter the IP address of the inverter in the address bar of the web browser.

Operating manual

SBxx-1AV-41-BE-en-10

47

8 Operation

SMA Solar Technology AG

2. Web browser signals a security vulnerability
After the IP address has been confirmed by pressing the enter key, a message might appear indicating that the connection to the user interface of the inverter is not secure. SMA Solar Technology AG guarantees that calling up the user interface is secure.
· Continue loading the user interface.  The login page of the user interface opens.
8.2 Logging In and Out of the User Interface
After a connection to the user interface of the inverter has been established, the login page opens. Log onto the user interface as described below.
Log in as Installer or User for the First Time
Procedure: 1. In the drop-down list Language, select the desired language. 2. In the User group drop-down list, select the entry Installer or User. 3. In the New password field, enter a new password for the selected user group. 4. In the Repeat password field, enter the new password again. 5. Select Login.
Log in as the User or Installer
1. In the drop-down list Language, select the desired language. 2. In the User group drop-down list, select the entry Installer or User. 3. Enter the password in the field Password. 4. Select Login.  The start page of the user interface opens.
Log Out as the User or Installer
1. On the right-hand side of the menu bar, select the menu User Settings. 2. In the subsequent context menu, select [Logout].  The login page of the user interface opens. The logout was successful.

48

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

8.3 Start Page Design of the User Interface

A

B

F

8 Operation
C

E
D
Figure 12: Start page design of the user interface (example)

Operating manual

SBxx-1AV-41-BE-en-10

49

8 Operation

SMA Solar Technology AG

Posi- Designation Description tion

A

Menu

Provides the following functions:
· Home Opens the user interface homepage
· Instantaneous values Current measured values of the inverter
· Device Parameters The various operating parameters of the inverter can be viewed and configured here depending on the user group.
· Events All events that have occurred in the selected time period are displayed here. The event types are Information, Warning and Error. Currently existing events of the types Error and Warning will be additionally displayed in the Device status viewlet. However, only the higher-priority event is displayed. If, for example, there is a Warning and an Error present at the same time, only the Error will be displayed.
· Device configuration Various settings for the inverter can be made here. The selection available is dependent on which user group you are logged in as and the operating system of the device with which the user interface has been called up.
· Data You will find all data that is saved in the internal memory of the inverter or on an external storage medium on this page.

B

User settings Provides the following functions, depending on the user group logged in:

· Starting the installation assistant

· SMA Grid Guard login

· Logout

C

Help

Provides the following functions: · Displaying information on Open Source licenses used · Link to the website of SMA Solar Technology AG

50

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

8 Operation

Posi- Designation Description tion

D

Status bar Displays the following information:

· Inverter serial number

· Inverter firmware version

· IP address of the inverter within the local network and/or IP address of the inverter during WLAN connection

· With WLAN connection: Signal strength of WLAN connection

· User group logged in

· Date and device time of the inverter

E

Current

Temporal progression of the PV power and the power consumption of the

power and household over the selected time period. Please note, the power con-

current con- sumption will only be displayed if an energy meter is installed in the PV

sumption system.

F

Status dis- The various areas display information on the current status of the PV sys-

play

tem.

· Device status

Displays whether the inverter is currently in a fault-free operating state or whether there is an Error or Warning present.

· Current power

Displays the power currently being generated by the inverter.

· Current consumption

Displays the current consumption of the household if an energy meter is installed in the PV system.

· Yield

Displays the energy yield of the inverter.

· Consumption

Displays the energy consumption of the household if an energy meter is installed in the PV system.

· Feed-in management

Displays whether the inverter is currently limiting its active power.

8.4 Activating the Smart Inverter Screen
With the Smart Inverter Screen, the most important inverter data is displayed directly on the user interface login page. To activate the Smart Inverter Screen, proceed as listed in the following.
Procedure: 1. Activate the user interface (see Section 8.1, page 44). 2. Log in as Installer or User.

Operating manual

SBxx-1AV-41-BE-en-10

51

8 Operation

SMA Solar Technology AG

3. Select the menu User Settings (see Section 8.3, page 49) on the start page of the user interface.
4. Select [Smart Inverter Screen].  The Smart Inverter Screen has been activated.
8.5 Starting the Installation Assistant

The installation assistant leads you step-by-step through the steps necessary for the initial configuration of the inverter.
Layout of the installation assistant

A

C

B

Figure 13: Layout of the installation assistant (example)

Position A
B C

Designation Configuration steps
User information Configuration field

Description
Overview of the installation assistant steps. The number of steps depends on the type of device and the additionally installed modules. The current step is highlighted in blue.
Information about the current configuration step and the setting options of the configuration step.
You can make settings in this field.

Requirement:  When configuring after completion of the first ten feed-in hours or after exiting the installation assistant, the SMA Grid Guard code must be available in order to change the grid-relevant parameters (see "Application for SMA Grid Guard Code" at www.SMA-Solar.com).
Procedure: 1. Activate the user interface (see Section 8.1, page 44). 2. Log in as Installer.

52

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

8 Operation

3. Select the menu User Settings (see Section 8.3, page 49) on the start page of the user interface.
4. In the context menu, select [Starting the installation assistant].  The installation assistant will open.
8.6 Activate WPS Function
The WPS function can be used for different purposes: · Automatic connection to a network (e.g. via router) · Direct connection between the product and an end device
Depending on the intended application of the WPS function, the procedure for activation will vary.
Activating WPS function for automatic connection to a network
Requirements:  WLAN must be activated in the product.  WPS must be activated on the router.
Procedure: 1. Activate the user interface (see Section 8.1, page 44). 2. Log in as Installer. 3. Start the installation assistant (see Section 8.5, page 52). 4. Select Network configuration. 5. Select WPS for WLAN network button in the WLAN tab. 6. Select Activate WPS. 7. Select Save and next and exit the installation assistant.  The WPS function is activated and the automatic connection to the network can be established.
Activating the WPS function for direct connection to the end device.
· Activate the WPS function on the inverter. To do this, tap on the enclosure lid of the inverter twice.  The blue LED flashes quickly for approx. two minutes. The WPS function is active during this time.
8.7 Switching WLAN On and Off
The inverter is equipped with an activated WLAN interface as standard. If you do not want to use WLAN, you can switch the WLAN function off and switch it on again whenever needed. In doing so, you can switch the WLAN direct connection and the WLAN connection in the local network on independently of each other.

Operating manual

SBxx-1AV-41-BE-en-10

53

8 Operation

SMA Solar Technology AG

Switching on the WLAN function only possible via Ethernet connection
If you switch off both the WLAN function for the direct connection and for the connection in the local network, access to the inverter user interface and therefore reactivation of the WLAN interface is only possible via an Ethernet connection.
The basic procedure for changing operating parameters is explained in another section (see Section 8.10 "Changing Operating Parameters", page 55).
Switching WLAN Off
If you would like to switch the WLAN function off completely, you must switch off both the direct connection and the connection in the local network.
Procedure: · To switch off the direct connection in the parameter group PV system communication > WLAN, select the parameter Soft-access-point is turned on and set this to No. · To switch off the connection in the local network in the parameter group PV system communication > WLAN, select the parameter WLAN is turned on and set this to No.
Switching WLAN On
If you have switched the WLAN function for direct connection or for connection in the local network off, you can switch the WLAN function back on in accordance with the following procedure.
Requirement:  If the WLAN function was previously switched off completely, the inverter must be connected to a computer or router via Ethernet.
Procedure: · To switch on the WLAN direct connection, in the parameter group PV system communication > WLAN, select the parameter Soft-access-point is turned on and set this to Yes. · To switch on the WLAN connection in the local network, in the parameter group System communication > WLAN, select the parameter WLAN is turned on and set this to Yes.
8.8 Switching the Dynamic Power Display Off
As standard, the inverter signals its power dynamically via the pulsing of the green LED. When doing so, the LED flashes on and off uniformly or is permanently lit at full power. The various gradations are related here to the set active power limit of the inverter. If this display is not desired, switch this function off in accordance with the following procedure. Once this has been done, the green LED is lit permanently to signalize feed-in operation. The basic procedure for changing operating parameters is explained in another section (see Section 8.10 "Changing Operating Parameters", page 55).
Procedure: · In the parameter group Device > Operation, select the parameter Dynamic power display via green LED and set this to Off.

54

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

8 Operation

8.9 Changing the Password
The password for the inverter can be changed for both user groups. Furthermore, the user group Installer can change the password for the user group User as well as its own password.
Procedure: 1. Activate the user interface (see Section 8.1, page 44). 2. Log into the user interface (see Section 8.2, page 48). 3. Call up the menu Device Parameters. 4. Select [Edit parameters]. 5. In the parameter group User Rights > Access Control change the password of the desired user group. 6. Select [Save all] to save the changes.
8.10 Changing Operating Parameters
The operating parameters of the inverter are set to certain values by default. You can change the operating parameters to optimize the performance of the inverter. This section describes the basic procedure for changing operating parameters. Always change operating parameters as described in this section. Some function-sensitive parameters can only be viewed by qualified persons and can only be changed by qualified persons by entering the personal SMA Grid Guard code.
No configuration via Sunny Explorer
Sunny Explorer does not support the configuration of inverters with their own user interface. The inverter can be detected via Sunny Explorer, however it is expressly not recommended to use Sunny Explorer to configure this inverter. SMA Solar Technology AG does not accept liability for missing or incorrect data and possibly resulting yield losses.
· Use the user interface for the configuration of the inverter.
Requirements:  Changes to grid-relevant parameters must be approved by the responsible grid operator.  Changes to grid-relevant parameters must be approved by the responsible grid operator.
Procedure: 1. Activate the user interface (see Section 8.1, page 44). 2. Log into the user interface (see Section 8.2, page 48). 3. Call up the menu Device Parameters. 4. Select [Edit parameters]. 5. Log in using the SMA Grid Guard code to change those parameters designated by a lock (only for installers): · Select the menu User Settings (see Section 8.3, page 49). · In the subsequent context menu, select [SMA Grid Guard login]. · Enter the SMA Grid Guard code and select [Login].

Operating manual

SBxx-1AV-41-BE-en-10

55

8 Operation

SMA Solar Technology AG

6. Expand the parameter group that contains the parameter which is to be configured. 7. Change the desired parameters. 8. Select [Save all] to save the changes.  The inverter parameters are set.
Accepting the settings
Saving the made settings is indicated by an hourglass symbol on the user interface. If the DC voltage is sufficient, the data is transferred directly to the inverter and accepted. If the DC voltage is too low (e. g. in the evening), the settings are saved, but they cannot be directly transferred to or accepted by the inverter. As long as the inverter has not yet received and accepted the settings, the hourglass symbol will continue to be displayed on the user interface. The settings will be accepted when there is sufficient DC voltage applied and the inverter restarts. As soon as the hourglass symbol appears on the user interface, the settings have been saved. The settings will not be lost. You can log off of the user interface and leave the system.
8.11 Configuring the Country Data Set

By default, the inverter is set to a universally valid country data set. You must adjust the country data set for the installation site.
The country data set must be set correctly.
If you select a country data set which is not valid for your country and purpose, it can cause a disturbance in the PV system and lead to problems with the grid operator. When selecting the country data set, you must always observe the locally applicable standards and directives as well as the properties of the PV system (e.g. PV system size, grid-connection point).
· If you are not sure which country data set is valid for your country or purpose, contact your grid operator for information on which country data set is to be configured.
The basic procedure for changing operating parameters is explained in another section (see Section 8.10 "Changing Operating Parameters", page 55).
Procedure: · In the parameter group Grid monitoring > Grid monitoring select the parameter Set country standard and set the required country data set.
8.12 Configuring Feed-In Management

Starting the installation assistant
1. Activate the user interface (see Section 8.1, page 44). 2. Log in as Installer. 3. Start the installation assistant (see Section 8.5, page 52).

56

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

8 Operation

4. Select [Save and continue] after each step up until the step Configure grid management service.
5. Make the settings as described in the following.
Setting the connected line conductors
· In the tab Feed-in management, select the line conductor to which the inverter is connected from the drop-down list Connected line conductors.
Making settings for systems with a higher unit (e.g. Sunny Home Manager)
1. Set Feed-in management at the grid-connection point to [Off]. 2. Set System control and power limitation to [On]. 3. In the drop-down list Operating mode active power, select the entry Active power
limitation P via system control. 4. In the drop-down list Operating mode for absent system control, select the entry Use
fallback setting. 5. In the field Fallback active power P enter the value to which the inverter is to limit its
nominal power in case of a communication failure to the higher unit at the end of the timeout time. 6. In the field Timeout, enter the time that the inverter is to wait before it limits its nominal power to the set fallback value. 7. If, in the event of a 0% or 0 W specification, the inverter is not permitted to feed small amounts of active power into the utility grid, select the entry Yes in the drop-down list Grid disconnection for 0% feeding. This ensures that in the event of a 0% or 0 W specification, the inverter disconnects from the utility grid and does not feed in active power.
Making settings for systems without higher-level unit (e.g. Sunny Home Manager).
1. Set Feed-in management at the grid-connection point to [On]. 2. Enter the total PV array power in the field Nominal PV system power. 3. In the drop-down list Operating mode of active power limitation at the grid-connection
point, select whether active power limitation is to be performed via a fixed specification in percent or in watts. 4. In the field Set active power limit at the grid-connection point, enter the value to which the active power at the grid-connection point is to be limited. The value must be set to 0 for zero export. 5. Set System control and power limitation to [On]. 6. For system control and power limitation based on set default values, select the entry Act. power lim. as % of Pmax or Active power limitation P in W and enter the respective default value. 7. If the inverter itself is to limit the active power limitation to the grid-connection point, perform the following steps:
· In the dropdown list Operating mode Active power, select Act. power lim. via PV system ctrl.

Operating manual

SBxx-1AV-41-BE-en-10

57

8 Operation

SMA Solar Technology AG

· In the drop-down list Operating mode for absent system control, select the entry Values maintained.
· In the drop-down list Grid disconnection for 0% feeding select the entry No.
8.13 Configuring the Modbus Function

The Modbus interface is deactivated by default and the communication ports 502 set. In order to access SMA invertes with SMA Modbus® or SunSpec® Modbus®, the Modbus interface must be activated. After activating the interface, the communication ports of both IP protocols can be changed. For information on commissioning and configuration of the Modbus interface, see the technical information "SMA and SunSpec Modbus® Interface" at www.SMA-Solar.com. For information on which Modbus registers are supported, see the technical information "Modbus® parameters and measured values" at www.SMA-Solar.com.
Data security during activated Modbus interface
If you activate the Modbus interface, there is a risk that unauthorized users may access and manipulate the data or devices in your PV system. To ensure data security, take appropriate protective measures such as:
· Set up a firewall · Close unnecessary network ports. · Only enable remote access via VPN tunnel. · Do not set up port forwarding at the communication port in use. · In order to deactivate the Modbus interface, reset the inverter to the default settings or
deactivate the activated parameter again.
Procedure: · Activate the Modbus interface and adjust the communication ports if necessary (see the technical information "SMA and SunSpec Modbus® Interface" at www.SMA-Solar.com).
8.14 Activating the Receipt of Control Signals (Only for Italy)

In order for PV systems in Italy to receive control commands from the grid operator, set the following parameters.
The basic procedure for changing operating parameters is explained in another section (see Section 8.10 "Changing Operating Parameters", page 55).

Parameter

Value/range

Resolution

Default

Application ID

0 to 16384

1

16384

GOOSE-Mac address 01:0C:CD:01:00:00 to 1 01:0C:CD:01:02:00

01:0C:CD:01:00:00

58

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

8 Operation

Procedure: 1. Select the parameter group External communication > IEC 61850 configuration. 2. In the field Application ID, enter the application ID of the grid operator gateway. You will receive this value from your grid operator. You can enter a value between 0 and 16384. The value 16384 indicates "deactivated". 3. In the field GOOSE-Mac address, enter the MAC address of the grid operator gateway from which the inverter is to receive the control commands. You will receive this value from your grid operator.  The receipt of control signals from the grid operator is activated.
8.15 Deactivating Grounding Conductor Monitoring

If the inverter is to be installed in an IT network or another grid configuration in which deactivation of the grounding conductor monitoring is required, deactivate the grounding conductor monitoring as follows. The basic procedure for changing operating parameters is explained in another section (see Section 8.10 "Changing Operating Parameters", page 55).
Procedure: · In the parameter group Grid monitoring > Grid monitoring > Country standard set the parameter PE connection monitoring to Off.
8.16 Saving the Configuration in a File
You can save the current configuration of the inverter in a file. You can use this file as a data backup for this inverter and then import this file into this inverter again or another inverter from the same type or device family to configure the inverter. When saving, only the device parameters will be saved, not any passwords.
Procedure: 1. Activate the user interface (see Section 8.1, page 44). 2. Log into the user interface (see Section 8.2, page 48). 3. Select the menu Device Configuration. 4. Select [Settings]. 5. In the context menu, select [Saving the configuration in a file]. 6. Follow the instructions in the dialog.
8.17 Adopting a Configuration from a File

To configure the inverter, you can adopt the configuration from a file. To be able to do this, you must first save the configuration of another inverter from the same type or device family in a file (see Section 8.16 "Saving the Configuration in a File", page 59). When saving, only the device parameters will be adopted, not any passwords.

Operating manual

SBxx-1AV-41-BE-en-10

59

8 Operation

SMA Solar Technology AG

Requirements:  Changes to grid-relevant parameters must be approved by the responsible grid operator.  The SMA Grid Guard code must be available (see "Application for SMA Grid Guard Code" at www.SMA-Solar.com).
Procedure: 1. Activate the user interface (see Section 8.1, page 44). 2. Log into the user interface as an Installer. 3. Select the menu Device Configuration. 4. Select [Settings]. 5. In the context menu, select [Adopting the configuration from a file]. 6. Follow the instructions in the dialog.
8.18 Updating the Firmware

If no automatic update is set in the communication product (e.g. SMA Data Manager or Sunny Home Manager) or in Sunny Portal, you have the option of carrying out a manual firmware update.
Requirements:  An update file with the desired inverter firmware must be available. The update file is, for example, available for download on the product page of the inverter at www.SMA-Solar.com. To download the update file, it is necessary to enter the serial number of the inverter.
Procedure: 1. Activate the user interface (see Section 8.1, page 44). 2. Log into the user interface (see Section 8.2, page 48). 3. Select the menu Device Configuration. 4. In the inverter row, click on the gear icon and select Update firmware. 5. Select [Browse] and select the update file for the inverter. 6. Select Update firmware. 7. Follow the instructions in the dialog.

60

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

9 Disconnecting the Inverter from Voltage Sources

9 Disconnecting the Inverter from Voltage Sources

Prior to performing any work on the inverter, always disconnect it from all voltage sources as described in this section. Always adhere to the prescribed sequence.
NOTICE
Destruction of the measuring device due to overvoltage
· Only use measuring devices with a DC input voltage range of 1000 V or higher.
Procedure: 1. Disconnect the AC circuit breaker and secure it against reconnection. 2. Set the DC load-break switch of the inverter to O.

3. Wait until the LEDs have gone out.
4. Use a current clamp to ensure that no current is present in the DC cables.

0.0A

5.

DANGER

Danger to life due to electric shock when touching exposed DC conductors or DC plug contacts if the DC connectors are damaged or loose
The DC connectors can break or become damaged, become free of the DC cables, or no longer be connected correctly if the DC connectors are released and disconnected incorrectly. This can result in the DC conductors or DC plug contacts being exposed. Touching live DC conductors or DC plug connectors will result in death or serious injury due to electric shock.
· Wear insulated gloves and use insulated tools when working on the DC connectors.
· Ensure that the DC connectors are in perfect condition and that none of the DC conductors or DC plug contacts are exposed.
· Carefully release and remove the DC connectors as described in the following.

Operating manual

SBxx-1AV-41-BE-en-10

61

9 Disconnecting the Inverter from Voltage Sources
6. Release and remove the DC connectors. To do so, insert a flat-blade screwdriver or an angled screwdriver (blade width: 3.5 mm) into one of the side slots and pull the DC connectors out. When doing so, do not lever the DC connectors out, but insert the tool into one of the side slots only to release the locking mechanism, and do not pull on the cable.
7. Ensure that no voltage is present at the DC inputs on the inverter using a suitable measuring device.

SMA Solar Technology AG
2 1

<30V
8. Unscrew the AC connector and pull it out of the jack for the AC connection. 1

2

62

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

10 Cleaning the Inverter

10 Cleaning the Inverter
NOTICE
Damage due to cleaning agents
The use of cleaning agents may cause damage to the product and its components. · Clean the product and all its components only with a cloth moistened with clear water. · Ensure that the inverter is free of dust, foliage and other dirt.

Operating manual

SBxx-1AV-41-BE-en-10

63

11 Troubleshooting

SMA Solar Technology AG

11 Troubleshooting
11.1 Forgotten Password
If you have forgotten the password for the inverter, you can unlock the inverter with a Personal Unlocking Key (PUK). For each inverter, there is one PUK for each user group (User and Installer). Tip: With PV systems in Sunny Portal, you can also assign a new password via Sunny Portal for the user group Installer. The password for the user group Installer is the same as the system password in Sunny Portal.
Procedure: 1. Request PUK (application form available at www.SMA-Solar.com). 2. Activate the user interface (see Section 8.1, page 44). 3. Enter the PUK instead of the password into the field Password. 4. Select Login. 5. Call up the menu Device Parameters. 6. Select [Edit parameters]. 7. In the parameter group User Rights > Access Control change the password of the desired user group. 8. Select [Save all] to save the changes.
PV Systems in Sunny Portal
The password for the user group Installer is also the system password for the PV system in Sunny Portal. Changing the password of the user group Installer can lead to the inverter no longer being able to be reached by Sunny Portal.
· Assign the changed password of the user group Installer as the new system password in Sunny Portal (see the Sunny Portal user manual at www.SMA-Solar.com).

64

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

11.2 Event Messages
Event number Message, cause and corrective measures
101
Grid fault The grid voltage or grid impedance at the connection point of the inverter is too high. The inverter has disconnected from the utility grid. Corrective measures:
· Check whether the grid voltage at the connection point of the inverter is permanently in the permissible range. If the grid voltage is outside the permissible range due to local grid conditions, contact the grid operator. The grid operator must agree with an adjustment of the voltage at the feed-in point or with a change of the monitored operating limits. If the grid voltage is permanently within the permissible range and this message is still displayed, contact the Service (see Section 14, page 94).
301
Grid fault The ten-minute average value of the grid voltage is no longer within the permissible range. The grid voltage or grid impedance at the connection point is too high. The inverter disconnects from the utility grid to maintain power quality. Corrective measures:
· During the feed-in operation, check whether the grid voltage at the connection point of the inverter is permanently in the permissible range. If the grid voltage is outside the permissible range due to local grid conditions, contact the grid operator. The grid operator must agree with an adjustment of the voltage at the feed-in point or with a change of the monitored operating limits. If the grid voltage is permanently within the permissible range and this message is still displayed, contact the Service (see Section 14, page 94).
401
Grid fault The inverter has disconnected from the utility grid. A stand-alone grid or a very large change in the power frequency was detected. Corrective measures:
· Check the grid connection for significant short-term frequency fluctuations.

Operating manual

SBxx-1AV-41-BE-en-10

65

11 Troubleshooting

SMA Solar Technology AG

Event number 501
601 801

Message, cause and corrective measures
Grid fault The power frequency is not within the permissible range. The inverter has disconnected from the utility grid. Corrective measures:
· If possible, check the power frequency and observe how often fluctuations occur. If fluctuations occur frequently and this message is displayed often, contact the grid operator and request approval to change the operating parameters of the inverter. If the grid operator gives his approval, discuss any changes to the operating parameters with Service (see Section 14, page 94).
Grid fault The inverter has detected an excessively high proportion of direct current in the grid current. Corrective measures:
· Check the grid connection for direct current. · If this message is displayed frequently, contact the grid operator and
check whether the monitoring threshold on the inverter can be raised.
Waiting for grid voltage > Grid failure > Check AC circuit breaker The AC cable is not correctly connected or the country data set is not correctly configured. Corrective measures:
· Make sure that the circuit breaker is switched on. · Ensure that the AC cable is not damaged and that it is connected
correctly. · Ensure that the country data set has been configured correctly. · Check whether the grid voltage at the connection point of the inverter is
permanently in the permissible range. If the grid voltage is outside the permissible range due to local grid conditions, contact the grid operator. The grid operator must agree with an adjustment of the voltage at the feed-in point or with a change of the monitored operating limits. If the grid voltage is permanently within the permissible range and this message is still displayed, contact the Service (see Section 14, page 94).

66

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

Event number 901 3401 to 3407
3501 3701

Message, cause and corrective measures
PE conn. missing > Check connection The grounding conductor is not correctly connected. Corrective measures:
· Ensure that the grounding conductor is correctly connected.
DC overvoltage > Disconnect generator Overvoltage at the DC input. This can destroy the inverter. This message is signalized additionally by rapid flashing of the LEDs. Corrective measures:
· Immediately disconnect the inverter from all voltage sources (see Section 9, page 61).
· Check whether the DC voltage is below the maximum input voltage of the inverter. If the DC voltage is below the maximum input voltage of the inverter, reconnect the DC connectors to the inverter.
· If the DC voltage exceeds the maximum input voltage of the inverter, ensure that the PV array has been correctly rated or contact the installer of the PV array.
· If this message is repeated frequently, contact the Service (see Section 14, page 94).
Insulation failure > Check generator The inverter has detected a ground fault in the PV array. Corrective measures:
· Check the PV system for ground faults (see Section 11.3, page 81).
Resid.curr.too.high > Check generator The inverter has detected a residual current due to temporary grounding of the PV array. Corrective measures:
· Check the PV system for ground faults (see Section 11.3, page 81).

Operating manual

SBxx-1AV-41-BE-en-10

67

11 Troubleshooting

SMA Solar Technology AG

Event number 3801 to 3805
6002 to 6412 6502
6512 6603 to 6604

Message, cause and corrective measures
DC overcurrent > Check generator Overcurrent at the DC input. The inverter briefly interrupts feed-in operation. Corrective measures:
· If this message is displayed frequently, ensure that the PV array has been correctly rated and wired.
Self diagnosis > Interference device The cause must be determined by the Service. Corrective measures:
· Contact the Service (see Section 14, page 94).
Self-diagnosis > Overtemperature The inverter has switched off due to excessive temperature. Corrective measures:
· Clean the cooling fins on the rear of the enclosure and the air ducts on the top using a soft brush.
· Ensure that the inverter has sufficient ventilation. · Ensure that the ambient temperature +40°C has not been exceeded. · Ensure that the inverter is not exposed to direct solar irradiation. Minimum operating temperature not reached The inverter will only recommence grid feed-in once the temperature has reached at least -25°C.
Self-diagnosis > Overload The cause must be determined by the Service. Corrective measures:
· Contact the Service (see Section 14, page 94).

68

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

Event number 6701 to 6702
7102
7105
7106 7110 7112 7113 7201 to 7202 7303

Message, cause and corrective measures
Communication disturbed Error in the communication processor, the inverter continues feeding in, however. The cause must be determined by the Service. Corrective measures:
· If this message is displayed frequently, contact the Service (see Section 14, page 94).
Parameter file not found or defective The parameter file was not found or is defective. The update failed. The inverter continues to feed in. Corrective measures:
· Copy the parameter file to the correct folder again.
Param. setting failed Parameters could not be set using the memory card. The inverter continues to feed in. Corrective measures:
· Ensure that the parameters are set correctly. · Ensure that the SMA Grid Guard code is available. Update file defect. The update file is defective. The update failed. The inverter continues to feed in. No update file found No new update file was found on the SD memory card. The update failed. The inverter continues to feed in. Update file successfully copied The memory card is full or write-protected Data storage not possible
Update main CPU failed The cause must be determined by the Service. Corrective measures:
· Contact the Service (see Section 14, page 94).

Operating manual

SBxx-1AV-41-BE-en-10

69

11 Troubleshooting

SMA Solar Technology AG

Event number 7320 7330 7331 7332 7333
7341 7342

Message, cause and corrective measures The device with serial number [xx] was successfully updated to firmware version [xxx]. The firmware update was completed successfully. Condition test failed The testing of the update conditions was successful. The firmware update package is suitable for this inverter. Update transport started Update file is being copied. Update transport successful Update file was copied successfully to the inverter's internal memory.
Update transport failed Update file could not be copied to the inverter's internal memory. In the event of connection with the inverter via WLAN, a poor connection quality can be the cause. Corrective measures:
· Retry update. · For WLAN connection: Improve the WLAN connection quality (e.g. via
WLAN repeater) or establish connection with the inverter via Ethernet. · If this message is displayed again, contact the Service (see Section 14,
page 94). Update Bootloader The inverter is performing a bootloader update.
Update Bootloader failed The bootloader update failed. Corrective measures:
· Retry update. · If this message is displayed again, contact the Service (see Section 14,
page 94).

70

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

Event number 7347
7348
7349
7350 7351 7352
7353

Message, cause and corrective measures
Incompatible file The configuration file is not suitable for this inverter. Corrective measures:
· Ensure that the selected configuration file is suitable for this inverter. · Retry import.
Incorrect file format The configuration file is not of the required format or is damaged. Corrective measures:
· Ensure that the selected configuration file is of the required format and is not damaged.
· Retry import. Incorrect login rights for configuration file The user group logged in does not have the user rights necessary to be able to import a configuration. Corrective measures:
· Log in as Installer. · Import configuration file again. Transfer of a configuration file has started The configuration file is being transferred. Update WLAN The inverter is updating the WLAN module. Update of WLAN not successful The update of the WLAN module failed. Corrective measures: · Retry update. · If this message is displayed again, contact the Service (see Section 14,
page 94). Update time zone database The inverter is updating the time zone database.

Operating manual

SBxx-1AV-41-BE-en-10

71

11 Troubleshooting

SMA Solar Technology AG

Event number 7354
7355 7356
7500 to 7501 7619
7702

Message, cause and corrective measures
Update of time zone database not successful The update of the time zone database failed. Corrective measures:
· Retry update. · If this message is displayed again, contact the Service (see Section 14,
page 94). Update WebUI The inverter is updating the inverter user interface.
Update of the WebUI not successful The update of the inverter user interface failed. Corrective measures:
· Retry update. · If this message is displayed again, contact the Service (see Section 14,
page 94).
Fan fault > Check inverter electronic and fan
Communication fault with meter unit > Check communication to meter The inverter is not receiving any data from the energy meter. Corrective measures:
· Ensure that the energy meter is correctly integrated into the same network as the inverter (see energy meter manual).
· For WLAN connection: Improve the WLAN connection quality (e.g. via WLAN repeater) or connect the inverter with the DHCP server (router) via Ethernet.
Interference device The cause must be determined by the Service. Corrective measures:
· Contact the Service (see Section 14, page 94).

72

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

Event number 8003
8101 to 8104 9002 9003 9005

Message, cause and corrective measures
Active power limited derating The inverter has reduced its power output for more than ten minutes due to excessive temperature. Corrective measures:
· Clean the cooling fins on the rear of the enclosure and the air ducts on the top using a soft brush.
· Ensure that the inverter has sufficient ventilation. · Ensure that the ambient temperature +40°C has not been exceeded. · Ensure that the inverter is not exposed to direct solar irradiation.
Communication disturbed The cause must be determined by the Service. Corrective measures:
· Contact the Service (see Section 14, page 94).
SMA Grid Guard code invalid The SMA Grid Guard code entered is incorrect. The operating parameters are still protected and cannot be changed. Corrective measures:
· Enter the correct SMA Grid Guard code. Grid parameter locked Changes to the grid parameters are now blocked. In order to be able to make changes to the grid parameters, from now on you must log in using the SMA Grid Guard code.
Changing of grid parameters not possible > Ensure DC supply This error can have the following causes:
· The parameters to be changed are protected. · The DC voltage at the DC input is not sufficient to run the main CPU. Corrective measures: · Enter the SMA Grid Guard code. · Ensure that at least the DC start voltage is available (green LED is
flashing, pulsing or glowing).

Operating manual

SBxx-1AV-41-BE-en-10

73

11 Troubleshooting

SMA Solar Technology AG

Event number 9007
10108 10109 10110
10118 10248
10249

Message, cause and corrective measures
Abort self-test The self-test (Italy only) was terminated. Corrective measures:
· Ensure that the AC connection is correct. · Restart the self-test. Time adjusted / old time Time adjusted / new time
Time synchronization failed: |tn0| No time information could be called up from the set NTP server. Corrective measures:
· Ensure that the NTP server was configured correctly. · Ensure that the inverter is integrated into a local network with Internet
connection. Parameter upload complete The configuration file was loaded successfully.
[Interface]: network busy The network is busy. Data exchange between the devices is not at an optimum and is greatly delayed. Corrective measures:
· Increase the query intervals. · If necessary, reduce the number of devices in the network.
[Interface]: network overloaded The network is overloaded. There is no data exchange between the devices. Corrective measures:
· Reduce the number of devices in the network. · If necessary, increase the data query intervals.

74

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

Event number 10250
10251 10252
10253

Message, cause and corrective measures
[Interface]: package error rate [ok / high] The package error rate has changed. If the package error rate is high, the network is overloaded or the connection to the network switch or DHCP server (router) is disturbed. Corrective measures if the package error rate is high:
· Ensure that with an Ethernet connection, the network cable and the network connector are not damaged and that the network connectors are correctly plugged.
· If necessary, increase the data query intervals. · If necessary, reduce the number of devices in the network. [Interface]: communication status goes to [OK / Warning / Error / Not connected] The communication status to the network switch or DHCP server (router) has changed. An additional error message may be displayed.
[Interface]: communication disrupted There is no valid signal on the network line. Corrective measures:
· Ensure that with an Ethernet connection, the network cable and the network connector are not damaged and that the network connectors are correctly plugged.
· Ensure that the DHCP server (router) and any network switches are signalizing correct operation.
[Interface]: connection speed goes to [100 Mbit / 10 Mbit] The data transfer rate has changed. The cause for the status [10 Mbit] can be a defective plug, a defective cable or the pulling or plugging of the network connector. Corrective measures if the status is [10 Mbit]:
· Ensure that with an Ethernet connection, the network cable and the network connector are not damaged and that the network connectors are correctly plugged.
· Ensure that the DHCP server (router) and any network switches are signalizing correct operation.

Operating manual

SBxx-1AV-41-BE-en-10

75

11 Troubleshooting

SMA Solar Technology AG

Event number 10254
10255 10282 10283

Message, cause and corrective measures
[Interface]: duplex mode goes to [Full / Half] The duplex mode (data transfer mode) has changed. The cause for the status [Half] can be a defective plug, a defective cable or the pulling or plugging of the network connector. Corrective measures if the status is [Half]:
· Ensure that with an Ethernet connection, the network cable and the network connector are not damaged and that the network connectors are correctly plugged.
· Ensure that the DHCP server (router) and any network switches are signalizing correct operation.
[Interface]: Network load OK The network load has returned to a normal range after being busy. [User group]-Login via [protocol] locked After several incorrect login attempts, login has been blocked for a limited time. In this case, the User login will be blocked for 15 minutes, the Grid Guard login for 12 hours. Corrective measures:
· Wait until the given time has expired and then retry login.
WLAN module faulty The WLAN module integrated in the inverter is defective. Corrective measures:
· Contact the Service (see Section 14, page 94).

76

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

Event number 10284
10285 10286
10339 10340 10341

Message, cause and corrective measures
No WLAN connection possible The inverter does not currently have a WLAN connection to the selected network. Corrective measures:
· Ensure that the SSID, the WLAN password and the encryption method have been entered correctly. The encryption method is specified by your WLAN router or WLAN Access Point and can be changed there.
· Ensure that the WLAN router or WLAN Access Point is in range and is signalizing correct operation.
· If this message is displayed often, improve the WLAN connection by using a WLAN repeater.
WLAN connection established Connection to the selected WLAN network has been established.
WLAN connection lost The inverter has lost WLAN connection to the selected network. Corrective measures:
· Ensure that the WLAN router or WLAN Access Point is still active. · Ensure that the WLAN router or WLAN Access Point is in range and is
signalizing correct operation. · If this message is displayed often, improve the WLAN connection by
using a WLAN repeater. Webconnect enabled The Webconnect function has been activated. Webconnect disabled The Webconnect function has been deactivated. Webconnect error: no connection No connection to Sunny Portal possible. Corrective measures:
· Ensure that the Internet connection is working properly. · Ensure that the Webconnect function is activated. · Ensure that the network cable at the inverter is correctly connected.

Operating manual

SBxx-1AV-41-BE-en-10

77

11 Troubleshooting

SMA Solar Technology AG

Event number 10343 10344 10345
10346 10347 10348
10349 10350

Message, cause and corrective measures
Webconnect error: Default gateway not configured The standard gateway was not configured. Corrective measures:
· Configure the standard gateway.
Webconnect error: DNS server not configured DNS server was not configured. Corrective measures:
· Configure DNS server.
Webconnect error: No reply to DNS request |xx| DNS server not available Corrective measures:
· Ensure that the address of the DNS server has been entered correctly. · Ensure that the network cable at the inverter is correctly connected.
Webconnect error: Unknown SIP proxy |xx| SIP-Proxy not available. Corrective measures:
· Ensure that the network cable at the inverter is correctly connected.
Webconnect error: Unknown STUN server [xx] STUN server not available. Corrective measures:
· Ensure that the network cable at the inverter is correctly connected.
Webconnect error: No reply to request to STUN server STUN server not available. Corrective measures:
· Ensure that the network cable at the inverter is correctly connected. · Check the configuration of the router.
Webconnect error: No reply to SIP option packs SIP server not available. Corrective measures:
· Check the configuration of the router.
Webconnect error: Registration rejected by SIP registrar The inverter is not registered in Sunny Portal. Corrective measures:
· Contact the Service (see Section 14, page 94).

78

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

Event number 10351
10352
10353
10502
10901 10902 10903 10904 10905

Message, cause and corrective measures
Webconnect error: Unknown SIP registrar |xx| SIP Registrar not available. Corrective measures:
· Ensure that the network cable at the inverter is correctly connected. · Check the configuration of the router.
Webconnect error: Faulty communication No connection to Sunny Portal possible. Corrective measures:
· Ensure that the Internet connection is working properly. · Ensure that the Webconnect function is activated. · Ensure that the network cable at the inverter is correctly connected.
Webconnect error: registration of the SIP registry has not responded SIP Registrar not fully available. Corrective measures:
· Ensure that the network cable at the inverter is correctly connected. · Check the configuration of the router.
Active power limited AC frequency The inverter has reduced its power due to a too-high power frequency to ensure grid stability. Corrective measures:
· If possible, check the power frequency and observe how often fluctuations occur. If fluctuations occur frequently and this message is displayed often, contact the grid operator and request approval to change the operating parameters of the inverter. If the grid operator gives his approval, discuss any changes to the operating parameters with Service (see Section 14, page 94).
Start self-test [xx] The self-test is running.
Uac RPro [xxx] V Preliminary result of the self-test
Uac Max [xxx] V Preliminary result of the self-test
Uac Min [xxx] V Preliminary result of the self-test
Uac Min Fast [xxx] V Preliminary result of the self-test

Operating manual

SBxx-1AV-41-BE-en-10

79

11 Troubleshooting

SMA Solar Technology AG

Event number 10906 10907 10908 10909 10910 10911 10912 27103 27104 27107 27301 27302 27312 29001
29004

Message, cause and corrective measures Fac SwMax [xxx] Hz Preliminary result of the self-test
Fac SwMin [xxx] Hz Preliminary result of the self-test
Fac Max [xxx] Hz Preliminary result of the self-test
Fac Min [xxx] Hz Preliminary result of the self-test
Disconn. threshold [xxx] [xx] Preliminary result of the self-test
Stand. Val. [xxx] [xx] Preliminary result of the self-test
Disconn. time [xx] s Preliminary result of the self-test
Set parameter The parameter changes are being adopted.
Parameters set successfully The parameter changes were successfully adopted.
Update file OK The update file found is valid.
Update communication The inverter is updating the communication component.
Update main CPU The inverter is updating the inverter component.
Update completed The inverter has successfully completed the update.
Inst. code valid The entered Grid Guard code is valid. Protected parameters have now been unlocked and you can adjust the parameters. The parameters will be automatically locked again after ten feed-in hours.
Grid parameters unchanged Changing the grid parameters is not possible.

80

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

11.3 Checking the PV System for Ground Faults

A ground fault may be present if the inverter beeps, the red LED lights up and the event numbers 3501, 3601 or 3701 are being displayed in the Results menu on the inverter user interface. The electrical insulation from the PV system to ground is defective or insufficient.
DANGER
Danger to life due to electric shock when touching live system components in case of a ground fault
If a ground fault occurs, parts of the system may still be live. Touching live parts and cables results in death or lethal injuries due to electric shock.
· Disconnect the product from voltage sources and make sure it cannot be reconnected before working on the device.
· Touch the cables of the PV array on the insulation only. · Do not touch any parts of the substructure or frame of the PV array. · Do not connect PV strings with ground faults to the inverter.
NOTICE
Destruction of the measuring device due to overvoltage
· Only use measuring devices with a DC input voltage range of 1000 V or higher.

Procedure: In order to check the PV system for ground faults, perform the following actions in the prescribed order. The exact procedure is described in the following sections.
· Check the PV system for ground faults by measuring the voltage. · If the voltage measurement was not successful, check the PV system via insulation resistance
measurement for ground faults.

Test by Measuring the Voltage
Proceed as follows to check each string in the PV system for ground faults.

Procedure:

1.

DANGER

Danger to life due to high voltages
· Disconnect the inverter from all voltage sources (see Section 9, page 61).

2. Measure the voltages: · Measure the voltage between the positive terminal and the ground potential (PE). · Measure the voltage between the negative terminal and the ground potential (PE).

Operating manual

SBxx-1AV-41-BE-en-10

81

11 Troubleshooting

SMA Solar Technology AG

· Measure the voltage between the positive and negative terminals. If the following results are present at the same time, there is a ground fault in the PV system:
 All measured voltages are stable.
 The sum of the two voltages to ground potential is approximately equal to the voltage between the positive and negative terminals.
3. If a ground fault is present, determine the location of the ground fault via the ratio of the two measured voltages and eliminate the ground fault.
4. If a definite ground fault cannot be measured and the message is still displayed, measure the insulation resistance.
5. Reconnect the strings without ground faults to the inverter and recommission the inverter (see inverter installation inverter).
Location of the ground fault

The example shows a ground fault between the second and third PV module.

V1 = 200 V

V2 = 300 V

100 V 100 V

100 V 100 V 100 V

+

82

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

11 Troubleshooting

Test by Measuring the Insulation Resistance
If the voltage measurement does not provide sufficient evidence of a ground fault, the insulation resistance measurement can provide more exact results.

+

Figure 14: Schematic diagram of the measurement
Calculating the insulation resistance
The expected total resistance of the PV system or of an individual string can be calculated using the following formula:

total
The exact insulation resistance of a PV module can be obtained from the module manufacturer or the datasheet.
For the resistance of a PV module an average value can be assumed: for thin-film PV modules approximately 40 MOhm and for polycrystalline and monocrystalline PV modules approximately 50 MOhm per PV module (for further information on calculating the insulation resistance see the Technical Information "Insulation Resistance (Riso) of Non-Galvanically Isolated PV Systems" at www.SMA-Solar.com).

Required devices:  Suitable device for safe disconnection and short-circuiting  Measuring device for insulation resistance
Device required for safe disconnection and short-circuiting of the PV array
The insulation resistance can only be measured with a suitable device for safe disconnection and short-circuiting of the PV array. If no suitable device is available, the insulation measurement must not be carried out.

Procedure: 1. Calculate the expected insulation resistance per string.

2.

DANGER

Danger to life due to high voltages
· Disconnect the inverter from all voltage sources (see Section 9, page 61).

Operating manual

SBxx-1AV-41-BE-en-10

83

11 Troubleshooting

SMA Solar Technology AG

3. Install the short circuit device. 4. Connect the measuring device for insulation resistance. 5. Short-circuit the first string. 6. Set the test voltage. The test voltage should be as close as possible to the maximum system
voltage of the PV modules but must not exceed it (see datasheet of the PV modules). 7. Measure the insulation resistance. 8. Eliminate the short circuit. 9. Measure the remaining strings in the same manner.
 If the insulation resistance of a string deviates considerably from the theoretically calculated value, there is a ground fault present in that string.
10. Reconnect to the inverter only those strings from which the ground fault has been eliminated. 11. Reconnect all other strings to the inverter. 12. Recommission the inverter. 13. If the inverter still displays an insulation error, contact the Service (see Section 14, page 94).
The PV modules might not be suitable for the inverter in the present quantity.

84

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

12 Decommissioning the Inverter

12 Decommissioning the Inverter

To decommission the inverter completely upon completion of its service life, proceed as described in this Section.
CAUTION
Risk of injury due to weight of product
Injuries may result if the product is lifted incorrectly or dropped while being transported or when attaching it to or removing it from the wall mounting bracket.
· Transport and lift the product carefully. Take the weight of the product into account. · Wear suitable personal protective equipment for all work on the product.

Procedure:

1.

DANGER

Danger to life due to high voltages
· Disconnect the inverter from all voltage sources (see Section 9, page 61).

2.

CAUTION

Risk of burns due to hot enclosure parts
· Wait 30 minutes for the enclosure to cool down.

3. Unscrew the RS485 plug and pull it out of the jack.

1 RS485

4. Screw the protective cap onto the RS485 jack.
5. Unscrew the swivel nut from the threaded sleeve for the network cable.

2 1

2

Operating manual

SBxx-1AV-41-BE-en-10

85

12 Decommissioning the Inverter
6. Unscrew and remove the threaded sleeve from the network port thread on the inverter.
7. Release the network cable plug and pull it out of the jack on the inverter.

SMA Solar Technology AG 1 2

8. Take the cable support sleeve out of the threaded sleeve and remove the network cable from the cable support sleeve.
9. Lead the network cable out of the threaded sleeve and the swivel nut.

2 1

10. Screw the protective cap onto the network port.

11. Unscrew and remove the antenna.

1 2

86

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
12. If there is a protective cap available, plug the protective cap onto the jack for connecting the antenna.
13. If an additional grounding or an equipotential bonding is connected to the inverter, remove the pan head screw M5x12 using a Torx screwdriver (TX 25) and remove the grounding cable.
14. Using a Torx screwdriver (TX 25), unscrew the leftand right-hand pan head screws M5x12 used to secure the inverter to the wall mounting bracket.

12 Decommissioning the Inverter

15. Remove the inverter by lifting it vertically up and off the wall mounting bracket.

16. Unscrew the screws for fastening the wall mounting bracket and remove the wall mounting bracket.
UP

17. If the inverter is to be stored or shipped, pack the inverter, the AC connector, the DC connector, the RJ45 protective sleeve, the antenna and the wall mounting bracket. Use the original packaging or packaging that is suitable for the weight and dimensions of the inverter.
18. Dispose of the inverter in accordance with the locally applicable disposal regulations for electronic waste.

Operating manual

SBxx-1AV-41-BE-en-10

87

13 Technical Data

SMA Solar Technology AG

13 Technical Data

13.1 DC/AC

13.1.1 Sunny Boy 3.0 / 3.6 / 4.0

DC Input

SB3.0-1AV-41

Maximum PV array power

5500 Wp

Maximum input voltage

600 V

MPP voltage range

125 V to 500 V

Rated input voltage

365 V

Minimum input voltage

100 V

Initial input voltage

125 V

Maximum input current,

15 A

input A

Maximum input current,

15 A

input B

Maximum input current

15 A

per string, input A

Maximum input current

15 A

per string, input B

Maximum short-circuit

20 A

current, input A*

Maximum short-circuit

20 A

current, input B*

Maximum reverse cur-

0 A

rent from the inverter in

the system for max.

1 ms

Number of indepen-

2

dent MPP inputs

Strings per MPP input

2

Overvoltage category

II

in accordance with

IEC 60664-1

* In accordance with IEC 62109-2: ISC PV

SB3.6-1AV-41 5500 Wp 600 V
125 V to 500 V 365 V 100 V 125 V 15 A 15 A 15 A 15 A 20 A 20 A 0 A
2 2 II

88

SBxx-1AV-41-BE-en-10

SB4.0-1AV-41 7500 Wp 600 V
125 V to 500 V 365 V 100 V 125 V 15 A 15 A 15 A 15 A 20 A 20 A 0 A
2 2 II
Operating manual

SMA Solar Technology AG

13 Technical Data

AC Output

SB3.0-1AV-41

SB3.6-1AV-41

SB4.0-1AV-41

Rated power at 230 V, 50 Hz

3000 W

3680 W

4000 W

Maximum apparent AC power at cos  = 1

3000 VA

3680 VA

4000 VA

Rated grid voltage

230 V

230 V

230 V

Nominal AC voltage 220 V / 230 V / 240 220 V / 230 V / 240 220 V / 230 V / 240

V

V

V

AC voltage range*

180 V to 280 V

180 V to 280 V

180 V to 280 V

Nominal AC current at 220 V

13.7 A

16 A

18.2 A

Nominal AC current at 230 V

13.1 A

16 A

17.4 A

Nominal AC current at 240 V

12.5 A

15.4 A

16.7 A

Maximum output current

13.7 A

16 A

18.2 A

Total harmonic distortion of the output current with total harmonic distortion of the AC voltage <2%, and AC power >50% of the rated power

3 %

3 %

3 %

Maximum output cur-

29 A

rent under fault condi-

tions

29 A

29 A

Inrush current

< 20% of the nominal < 20% of the nominal < 20% of the nominal

AC current for a

AC current for a

AC current for a

maximum of 10 ms maximum of 10 ms maximum of 10 ms

Rated power frequency

50 Hz

50 Hz

50 Hz

AC power frequency* 50 Hz / 60 Hz

50 Hz / 60 Hz

50 Hz / 60 Hz

Operating range at AC power frequency 50 Hz

45 Hz to 55 Hz

45 Hz to 55 Hz

45 Hz to 55 Hz

Operating range at AC power frequency 60 Hz

55 Hz to 65 Hz

55 Hz to 65 Hz

55 Hz to 65 Hz

Operating manual

SBxx-1AV-41-BE-en-10

89

13 Technical Data

SMA Solar Technology AG

Power factor at rated power

SB3.0-1AV-41 1

SB3.6-1AV-41 1

SB4.0-1AV-41 1

Displacement power 0.8 overexcited to 0.8 0.8 overexcited to 0.8 0.8 overexcited to 1 to

factor cos , adjustable underexcited

underexcited

0.8 underexcited

Feed-in phases

1

1

1

Phase connection

1

1

1

Overvoltage category

III

III

III

in accordance with

IEC 60664-1

* Depending on the configured country data set

Efficiency

Maximum efficiency, max
European weighted efficiency, EU

SB3.0-1AV-41 97.0 %
96.4 %

SB3.6-1AV-41 97.0 %
96.5 %

SB4.0-1AV-41 97.0 %
96.5 %

13.1.2 Sunny Boy 5.0 / 6.0

DC Input

Maximum PV array power Maximum input voltage MPP voltage range Rated input voltage Minimum input voltage Initial input voltage Maximum input current, input A Maximum input current, input B Maximum input current per string, input A Maximum input current per string, input B Maximum short-circuit current, input A*

SB5.0-1AV-41 7500 Wp 600 V
125 V to 500 V 365 V 100 V 125 V 15 A 15 A 15 A
15 A
20 A

SB6.0-1AV-41 9000 Wp 600 V
125 V to 500 V 365 V 100 V 125 V 15 A 15 A 15 A
15 A
20 A

90

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

13 Technical Data

Maximum short-circuit current, input B*

SB5.0-1AV-41 20 A

SB6.0-1AV-41 20 A

Maximum reverse current from

0 A

0 A

the inverter in the system for

max. 1 ms

Number of independent MPP

2

2

inputs

Strings per MPP input

2

2

Overvoltage category in accor-

II

II

dance with IEC 60664-1

* In accordance with IEC 62109-2: ISC PV

AC Output

Rated power at 230 V, 50 Hz*

SB5.0-1AV-41 5000 W

SB6.0-1AV-41 6000 W

Maximum apparent AC power at cos  = 1**

5000 VA

6000 VA

Rated grid voltage

230 V

230 V

Nominal AC voltage

220 V / 230 V / 240 220 V / 230 V / 240

V

V

AC voltage range***

180 V to 280 V

180 V to 280 V

Nominal AC current at 220 V

22.8 A

26.1 A

Nominal AC current at 230 V

22 A

26.1 A

Nominal AC current at 240 V

21 A

25 A

Maximum output current****

22.8 A

26.1 A

Total harmonic distortion of the output current with total harmonic distortion of the AC voltage <2%, and AC power >50% of the rated power

3 %

3 %

Maximum output current under fault conditions

29 A

29 A

Inrush current

< 20% of the nominal < 20% of the nominal

AC current for a

AC current for a

maximum of 10 ms maximum of 10 ms

Rated power frequency

50 Hz

50 Hz

AC power frequency***

50 Hz / 60 Hz

50 Hz / 60 Hz

Operating range at AC power frequency 50 Hz 45 Hz to 55 Hz

45 Hz to 55 Hz

Operating range at AC power frequency 60 Hz 55 Hz to 65 Hz

55 Hz to 65 Hz

Operating manual

SBxx-1AV-41-BE-en-10

91

13 Technical Data

SMA Solar Technology AG

Power factor at rated power Displacement power factor cos , adjustable
Feed-in phases

SB5.0-1AV-41

SB6.0-1AV-41

1

1

0.8 overexcited to 1 to 0.8 overexcited to 0.8

0.8 underexcited

underexcited

1

1

Phase connection

1

1

Overvoltage category in accordance with

III

III

IEC 60664-1

* According to VDE-AR-N 4105, the rated power at 230 V, 50 Hz of the SB5.0-1AV-41 is 4600 W ** According to VDE-AR-N 4105, the rated power at 230 V, 50 Hz of the SB5.0-1AV-41 is 4600 VA *** Depending on the configured country data set **** According to AS 4777, the maximum output current is 21.7 A

Efficiency

Maximum efficiency, max European weighted efficiency, EU

SB5.0-1AV-41 97.0 % 96.5 %

SB6.0-1AV-41 97.0 % 96.5 %

13.2 Climatic Conditions

Installation in accordance with IEC 60721-3-3, Class 4K4H

Extended temperature range

-25°C to +60°C

Extended humidity range

0% to 100%

Extended air pressure range

79.5 kPa to 106 kPa

Transport in accordance with IEC 60721-3-2, Class 2K3

Temperature range

-25°C to +70°C

13.3 Protective Devices
DC reverse polarity protection Input-side disconnection point AC short-circuit current capability Grid monitoring Maximum permissible fuse protection Ground fault monitoring All-pole sensitive residual-current monitoring unit

Short-circuit diode DC load-break switch
Current control SMA Grid Guard 6
32 A Insulation monitoring: Riso > 200 k
Available

92

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG
13.4 Equipment
DC connection AC connection WLAN SMA Speedwire/Webconnect RS485
13.5 Torques
Screws for securing the inverter to the wall mounting bracket Additional grounding SUNCLIX swivel nut Screw terminals of the AC connector
13.6 Data Storage Capacity
Energy yields in the course of the day Daily yields Event messages for users Event messages for installers

13 Technical Data
SUNCLIX DC connector AC connector As standard As standard As standard
2.5 Nm 2.5 Nm 2.0 Nm 1.4 Nm
63 days 30 years 1024 events 1024 events

Operating manual

SBxx-1AV-41-BE-en-10

93

14 Contact

SMA Solar Technology AG

14 Contact

If you have technical problems with our products, please contact the SMA Service Line. The following data is required in order to provide you with the necessary assistance:
· Device type · Serial number · Firmware version · Event message · Mounting location and mounting height · Type and number of PV modules · Optional equipment, e.g. communication products · Use the name of the system in Sunny Portal (if available) · Access data for Sunny Portal (if available) · Special country-specific settings (if available)

Deutschland SMA Solar Technology AG
Österreich Niestetal
Schweiz Sunny Boy, Sunny Mini Central, Sunny Tripower: +49 561 95221499
Monitoring Systems (Kommunikationsprodukte): +49 561 95222499
Hybrid Controller (PV-Diesel-Hybridsysteme): +49 561 9522-3199
Sunny Island, Sunny Boy Storage, Sunny Backup: +49 561 9522-399
Sunny Central, Sunny Central Storage: +49 561 9522-299
SMA Online Service Center: www.SMA-Service.com

Belgien Belgique België Luxemburg Luxembourg Nederland

SMA Benelux BVBA/SPRL Mechelen +32 15 286 730 SMA Online Service Center: www.SMA-Service.com

Cesko

SMA Service Partner TERMS

Magyarország a.s.

Slovensko

+420 387 6 85 111

SMA Online Service Center:

www.SMA-Service.com

Türkiye

SMA Service Partner DEKOM Ltd. ti.
+90 24 22430605
SMA Online Service Center: www.SMA-Service.com

France

SMA France S.A.S. Lyon +33 472 22 97 00 SMA Online Service Center : www.SMA-Service.com

 

SMA Service Partner AKTOR FM.  +30 210 8184550 SMA Online Service Center: www.SMA-Service.com

94

SBxx-1AV-41-BE-en-10

Operating manual

SMA Solar Technology AG

14 Contact

España Portugal
Italia

SMA Ibérica Tecnología Solar, S.L.U. Barcelona +34 935 63 50 99 SMA Online Service Center: www.SMA-Service.com
SMA Italia S.r.l. Milano +39 02 8934-7299 SMA Online Service Center: www.SMA-Service.com

United Kingdom
Australia

United Arab SMA Middle East LLC Emirates Abu Dhabi
+971 2234 6177
SMA Online Service Center: www.SMA-Service.com



SMA Solar (Thailand) Co., Ltd.



+66 2 670 6999

India 

South Africa SMA Solar Technology South Argentina

Africa Pty Ltd.

Brasil

Cape Town

Chile

08600SUNNY (08600 78669) Perú

International: +27 (0)21 826

0699

SMA Online Service Center:

www.SMA-Service.com

Other coun- International SMA Service Line

tries

Niestetal

00800 SMA SERVICE (+800 762 7378423)

SMA Online Service Center: www.SMA-Service.com

SMA Solar UK Ltd. Milton Keynes +44 1908 304899 SMA Online Service Center: www.SMA-Service.com
SMA Australia Pty Ltd. Sydney Toll free for Australia: 1800 SMA AUS (1800 762 287) International: +61 2 9491 4200 SMA Solar India Pvt. Ltd. Mumbai +91 22 61713888
SMA Technology Korea Co., Ltd.  +82-2-520-2666 SMA South America SPA Santiago de Chile +562 2820 2101

Operating manual

SBxx-1AV-41-BE-en-10

95

15 EU Declaration of Conformity

SMA Solar Technology AG

15 EU Declaration of Conformity
within the scope of the EU directives · Electromagnetic compatibility 2014/30/EU (29.3.2014 L 96/79-106) (EMC) · Low Voltage Directive 2014/35/EU (29.3.2014 L 96/357-374) (LVD) · Radio Equipment Directive 2014/53/EU (22.5.2014 L 153/62) (RED)
SMA Solar Technology AG confirms herewith that the products described in this document are in compliance with the fundamental requirements and other relevant provisions of the abovementioned directives. The entire EU Declaration of Conformity can be found at www.SMASolar.com.

96

SBxx-1AV-41-BE-en-10

Operating manual

www.SMA-Solar.com


ST4 PDF Engine (Build 6.0.0.0)