Site Master™ S820E Specifications 6 of 28 PN: 11410-00749 Rev. V S820E TDS Cable and Antenna Analyzer (continued) Measurement Accuracy1 (OSLN50A-8 or OSLNF50A-8, TOSLN50A-8 or TOSLNF50A-8) Corrected Measurement Uncertainty (Transmission from Port 1 to Port 2) 1.

Current View
11410-00749V
Technical Data Sheet
Microwave Site MasterTM
Cable & Antenna Analyzer with Optional VNA and VVM Modes
S820E
1 MHz to 8 GHz, 14 GHz, 20 GHz, 30 GHz, 40 GHz

Site MasterTM S820E

Specifications

Introduction
Anritsu is proud to introduce the world's most advanced Site Master. With microwave frequency coverage up to 40 GHz, the new S820E completely redefines the standards for portable handheld analyzers, setting another new industry benchmark for performance and accuracy. The new S820E is the culmination of over 50 years of microwave development, utilizing the very latest technologies to deliver accuracy and performance previously reserved only for benchtop instruments. Based on a true 4 channel receiver design, the S820E offers true VNA performance in a portable package. Optional VNA Mode provides fully reversing S-parameter measurements anywhere, anytime. Optional Vector Voltmeter Mode (VVM) with standard A/B and B/A ratio may be used as drop-in replacement for legacy VVM products.

Cable and Antenna Analyzer Highlights
· 1-Port Measurements: RL, VSWR, Cable Loss, DTF, Phase, Smith Chart
· 2-Port Measurements: Transmission, Cable Loss
· Display: Single or Dual Measurement Touchscreen
· Calibration: Coaxial (OSL, TOSL), Waveguide (SSL, SSLT)

· Dynamic Range: 110 dB (20 MHz to 40 GHz) · Frequency Resolution: 1 Hz (1 MHz to 40 GHz) · Sweep Speed: 550 µs/data point · Calibration Temperature Window: ±10 °C · Full Temperature Calibration Kits: ­10 °C to +55 °C

Vector Network Analyzer Highlights
· Fully Reversing Error Corrected Measurements · Measure All Four S-Parameters Simultaneously · Flexible Trace Display Layout: 1, 2, 3, or 4, and Overlay on top · Calibration Interpolation and Through Update

· Independent Markers and Limits Per Trace · Fast Sweeps (<600 µs/pt) Even in 5 kHz IFBW · Arbitrary Data Point Setting · Port Reference Plane Extension (Distance And/or Loss)

Vector Voltmeter Highlights
· A/B & B/A Ratio Measurement Standard
· Reflection/Transmission Measurement Standard
· Reference Auto-tune reduces or eliminates need for common 10 MHz reference (for A/B & B/A Ratio measurement only)

· Vector Error Correction for Absolute Measurement (Reflection/Transmission only)
· 4 Flexible Data Display Formats
· Table Display allows 12 Measurements and 1 Reference, Simultaneously

Capabilities and Functional Highlights
· Benchtop VNA Performance
· Intuitive GUI + Classic Mode
· 2-Port Measurements Standard
· 2-Port Cable Loss
· Std High Accuracy Power Meter (Requires external USB sensor)
· USB Transmission Sensors up to 40 GHz
· Ethernet/USB Connectivity
· USB Peripheral Support
· Touchscreen Popup Keyboard
· easyTestTM Automated Scripts
· Embeddded Help (FAQ and User Guide)
· Optical connector inspection with IEC 61300-3-35 based Pass/Fail standard (Requires USB Video Inspection Probe, sold separately)
Microwave Site MasterTM S820E Cable and Antenna Analyzer Featuring 8.4 in Daylight Viewable Touchscreen Compact Size: 273 mm x 199 mm x 91 mm (10.7 in x 7.8 in x 3.6 in), Lightweight: 3.0 kg (6.6 lb)

2 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Site MasterTM S820E

Table of Contents
Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cable and Antenna Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 High Accuracy Power Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Video Inspection Probe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Vector Network Analyzer (Option 440) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Vector Voltmeter (Option 441). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Line Sweep ToolsTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 easyTest ToolsTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Programmable Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Standard Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Definitions

Warm-Up Time Reference Signal Typical Performance
Uncertainty Calibration Cycle

All specifications and characteristics apply to Revision 2 instruments under the following conditions, unless otherwise stated:
After 10 minutes of warm-up time, where the instrument is left in the ON state.
When using internal reference signal.
Typical specifications that are not in parenthesis are not tested and not warranted. They are generally representative of characteristic performance.
Typical specifications in parenthesis () represent the mean value of measured units and do not include any guard-bands or uncertainties. They are not warranted.
A coverage factor of x1 is applied to the measurement uncertainties to facilitate comparison with other industry handheld analyzers.
Calibration is within the recommended 12 month period (residual specifications also require calibration kit calibration cycle adherence.)
All specifications subject to change without notice. For the most current data sheet, please visit the Anritsu web site: www.anritsu.com

S820E TDS

PN: 11410-00749 Rev. V

3 of 28

Site MasterTM S820E

Specifications

Cable and Antenna Analyzer

Measurements
1-Port Measurements
2-Port Measurements

Return Loss Distance-to-Fault (DTF) Return Loss Cable Loss VSWR Distance-to-Fault (DTF) VSWR Smith Chart 50 /75  (Advanced Mode Only) Phase (Advanced Mode Only)
Transmission (Advanced Mode Only) Transmission with External Sensor (Advanced Mode Only) Cable Loss (2-Port) with External Sensor (Classic Mode Only)

Setup Parameters Classic Mode
Measurement Display Frequency DTF Windowing Amplitude Sweep
Marker
Trace Limit Calibration Calibration Setup Save/Recall/File Management1

Single Display with independent markers F1/F2 D1/D2, Units m/ft, DTF Aid, Cable List, Cable Loss, Propagation Velocity Rectangular, Nominal Side Lobe, Low Side Lobe, Minimum Side Lobe Top, Bottom Auto Scale, Full Scale, Scale Preset Data Points (130, 259, 517, 1033, 2065), Run/Hold, Sweep Type (Single/Continuous), RF Immunity (High/Low), RF Power in Hold (On/Off), Smoothing, Sweep Averaging (1 to 1000), Trace Markers 1 to 6 (On/Off), Delta Makers 2 to 4 (Ref Mk1), Marker to Peak/Valley, Marker Table, Marker 5 (Peak/Valley between M1 and M2), Marker 6 (Peak/Valley between M3 and M4) Copy Trace To Memory, Trace Display, Trace Math On/Off, Edit Value, Limit Alarm (On/ Off), Pass/Fail (On/Off), Limit Preset Start Calibration, Calibration Info, Calibration Correction (On/ Off) Coax, Waveguide Measurement (.dat), Setups (.stp), Screen Shots (.png), Text (.txt), CSV (.csv)

Setup Parameters Advanced Mode

Measurement Display Single/Dual Display with independent markers

Frequency Start Frequency (F1), Stop Frequency (F2)

Distance Start Distance (D1), Stop Distance (D2), Units (meters/feet), DTF Aid

DTF Setup DTF Line Type (Coax/Waveguide), Cable List, Cable Loss, Propagation Velocity, Windowing (Rectangular, Nominal Side Lobe, Low Side Lobe, Minimum Side Lobe)

Amplitude Top, Bottom, Auto Scale, Full Scale, Scale Preset

Sweep

Data Points (130, 259, 517, 1033, 2065), Run/Hold, Sweep Type (Single/Continuous), RF Immunity (High/Low), RF Power in Hold (On/Off), Source Power (High/Low), IFBW (10 Hz, 100 Hz, 1 kHz, 100 kHz), Smoothing, Sweep Averaging (1 to 1000)

Markers

Markers 1 to 8 (On/Off), Delta Makers 2 to 8 (Ref Mk1), Marker to Peak/Valley, Marker Tracking (On/Off), Marker Table, Marker 5 and 7 (Peak/Valley between M1 and M2), Marker 6 and 8 (Peak/Valley between M3 and M4)

Trace Copy Trace to Memory, Trace Display, Trace Math

Limit

Active Limit (Upper/Lower), Limit State (Off, Single, Segmented), Move Active Limit, Edit Segments (42 upper and 42 lower segments maximum), Limit Alarm (On/Off), Pass/Fail (On/Off), Limit Preset

Calibration Start Calibration, Thru Update, Calibration Info, Calibration Correction (On/Off) Save/Recall/File Management1 Measurement (.dat), Setups (.stp), Screen Shots (.png), Text (.txt), CSV (.csv)

Frequency

Frequency Range Frequency Accuracy
Stability Aging
Frequency Resolution

1 MHz to 8 GHz, 14 GHz, 20 GHz, 30 GHz, 40 GHz (frequency option dependent) ±1.0 ppm at 23 °C ±1.0 ppm from ­10 °C to +55 °C, typical ±1.0 ppm/yr, typical 1 Hz

IFBW

Advanced Mode Only 10 Hz, 100 Hz, 1 kHz, 100 kHz

Output Power RF Immunity2

1 MHz to 8 GHz +5 dBm, typical (High); ­20 dBm, typical (Low) >8 GHz to 40 GHz ­3 dBm, typical (High); ­20 dBm, typical (Low)
+17 dBm, typical

1. Text (.txt) and CSV (.csv) files cannot be recalled to the instrument. 2. +13 dBm for interfering signals landing in-band.

4 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Site MasterTM S820E

Cable and Antenna Analyzer (continued)

Measurement Speed1
Reflection/Transmission Measurements Transmission Ext. Sensor (2-port Cable Loss)

 550 µs/data point, RF immunity low, typical Determined by USB sensor and may vary with model used, not specified.

Dynamic Range2,3 (High Power, 10 Hz IFBW, 10 averages Port 1 to Port 2)
1 MHz to 10 MHz  85 dB (105 dB, typical) >10 MHz to 8 GHz  100 dB (115 dB, typical) >8 GHz to 40 GHz  100 dB (110 dB, typical)

Receiver Compression Port 1 or Port 2 (0.1 dB compression)
1 MHz to 40 GHz +5 dBm, typical
High Level Noise4 (High Power, 100 Hz IFBW, 20 MHz to 40 GHz)
Magnitude ±0.006 dB (±0.001 dB, typical) rms Phase ±0.090° (±0.060°, typical)

Temperature Stability (10 MHz to 40 GHz, ratio measurement, ports shorted)
Magnitude ±0.02 dB/°C, typical Phase ±0.3 degrees/°C, typical

Smoothing

Range 0 % to 20 %

System Impedance
Port 1 or Port 2 50  standard, 75  with 50  to 75  adapter

Return Loss
Measurement Display Range Resolution

0 dB to 1000 dB 0.01 dB

VSWR

Measurement Display Range 1 to 1000 Resolution 0.01

Cable Loss
Measurement Display Range Resolution

0 dB to 500 dB 0.01 dB

Distance-to-Fault
Vertical Range Return Loss Vertical Range VSWR
Fault Resolution (meters) Horizontal Range (meters)

0 dB to 1000 dB
1 to 1000 (1.5 x 108 x vp)/F (vp = propagation velocity constant, F is F2­F1 in Hz)
0 to (Data Points ­ 1) x Fault Resolution, to a maximum of 1500 m (4921 ft)

1-Port Phase
Measurement Display Range Resolution

­450 ° to +450 ° 0.01 °

Smith Chart

Impedance 50 , 75  Resolution 0.01

Cable Loss 2-Port (Classic Mode Only)
Measurement Display Range Resolution

­1000 dB to +1000 dB 0.01 dB

Transmission (Advanced Mode Only)
Measurement Display Range Resolution

­1000 dB to +1000 dB 0.01 dB

Transmission Ext Sensor (Advanced Mode Only)
Measurement Display Range ­1000 dB to +1000 dB Resolution 0.01 dB

1. 100 kHz IFBW, typical. 2. Dynamic range is defined as the difference between output power and receiver noise floor. 3. Decrease specification by 5 dB between 8 GHz and 14 GHz. Crosstalk may reduce dynamic range up to 20 dB (typical) at lower IF bandwidths ( 10 kHz) when measuring highly
reflective DUT's from 4 GHz to 8 GHz. Reflection measurements are not affected. 4. High Level Noise below 20 MHz is increased by a factor of 5.0. High Level Noise (Phase only) above 20 GHz is increased by a factor of 1.5.

S820E TDS

PN: 11410-00749 Rev. V

5 of 28

Site MasterTM S820E

Cable and Antenna Analyzer (continued)

Measurement Accuracy1 (OSLN50A-8 or OSLNF50A-8, TOSLN50A-8 or TOSLNF50A-8)

Frequency Range

Directivity (dB)

Source Match (dB)

Load Match (dB)

1 MHz to 6 GHz

 42

 33

 42

> 6 GHz to 8 GHz

 37

 33

 37

Corrected Measurement Uncertainty (Transmission from Port 1 to Port 2)

Specifications

Reflection Tracking (dB)
±0.08
±0.08

Transmission Tracking (dB)
±0.06
±0.06

Return Loss Magnitude Uncertainty

10

100

20 MHz - 6 GHz 6 GHz - 8 GHz

Return Loss Phase Uncertainty

20 MHz - 6 GHz 6 GHz - 8 GHz

1

10

Uncertainty (degrees)

Uncertainty (dB)

Uncertainty (dB)

0.1

1

-40

-35

-30

-25

-20

-15

-10

-5

0

-40

-35

-30

-25

-20

-15

-10

-5

0

Return Loss Magnitude (dB)

Return Loss Magnitude (dB)

Transmission Magnitude Uncertainty

10

100

20 MHz - 8 GHz

Transmission Phase Uncertainty

20 MHz - 8 GHz

1

10

Uncertainty (degrees)

0.1

1

0.01

0.1

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

Transmission Magnitude (dB)

Transmission Magnitude (dB)

1. Full 2-Port calibration with isolation, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. OSLN50A-8, OSLNF50A-8, TOSLN50A-8, or TOSLNF50A-8 calibration kit. Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable. Reflection and Transmission Tracking are typical.

6 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Cable and Antenna Analyzer (continued)

Measurement Accuracy1 (OSLN50A-18 or OSLNF50A-18, TOSLN50A-18 or TOSLNF50A-18)

Frequency Range

Directivity (dB)

Source Match (dB)

Load Match (dB)

1 MHz to 6 GHz

 42

 33

 42

> 6 GHz to 9 GHz

 37

 33

 37

> 9 GHz to 18 GHz

 33

 26

 33

Corrected Measurement Uncertainty (Transmission from Port 1 to Port 2)

Site MasterTM S820E

Reflection Tracking (dB)
±0.08 ±0.08 ±0.04

Transmission Tracking (dB)
±0.06 ±0.06 ±0.03

Return Loss Magnitude Uncertainty

10

100

20 MHz - 6 GHz

6 GHz - 8 GHz 8 GHz - 18 GHz

Return Loss Phase Uncertainty

20 MHz - 6 GHz 6 GHz - 8 GHz 8 GHz - 18 GHz

1

10

Uncertainty (degrees)

Uncertainty (dB)

Uncertainty (dB)

0.1

1

-40

-35

-30

-25

-20

-15

-10

-5

0

-40

-35

-30

-25

-20

-15

-10

-5

0

Return Loss Magnitude (dB)

Return Loss Magnitude (dB)

Transmission Magnitude Uncertainty

10

100

20 MHz - 8 GHz

8 GHz - 14 GHz

14 GHz - 18 GHz

1

10

Transmission Phase Uncertainty

20 MHz - 8 GHz 8 GHz - 14 GHz 14 GHz - 18 GHz

Uncertainty (degrees)

0.1

1

0.01

0.1

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

Transmission Magnitude (dB)

Transmission Magnitude (dB)

1. Full 2-Port calibration with isolation, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. OSLN50A-18, OSLNF50A-18, TOSLN50A-18, or TOSLNF50A-18 calibration kit. Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable. Reflection and Transmission Tracking are typical.

S820E TDS

PN: 11410-00749 Rev. V

7 of 28

Site MasterTM S820E

Cable and Antenna Analyzer (continued)

Measurement Accuracy1 (TOSLK50A-20 or TOSLKF50A-20)

Frequency Range

Directivity (dB)

1 MHz to 10 GHz

 42

> 10 GHz to 20 GHz

 36

Source Match (dB)
 33
 26

Corrected Measurement Uncertainty (Transmission from Port 1 to Port 2)

Return Loss Magnitude Uncertainty

10

100

20 MHz - 8 GHz

8 GHz - 20 GHz

Specifications

Load Match (dB)
 42
 36

Reflection Tracking (dB)
±0.08
±0.04

Transmission Tracking (dB)
±0.06
±0.03

Return Loss Phase Uncertainty

20 MHz - 8 GHz 8 GHz - 20 GHz

1

10

Uncertainty (degrees)

Uncertainty (dB)

Uncertainty (dB)

0.1

1

-40

-35

-30

-25

-20

-15

-10

-5

0

-40

-35

-30

-25

-20

-15

-10

-5

0

Return Loss Magnitude (dB)

Return Loss Magnitude (dB)

Transmission Magnitude Uncertainty

10

100

20 MHz - 8 GHz

8 GHz - 14 GHz

14 GHz - 20 GHz

1

10

Transmission Phase Uncertainty

20 MHz - 8 GHz 8 GHz - 14 GHz 14 GHz - 20 GHz

Uncertainty (degrees)

0.1

1

0.01

0.1

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

Transmission Magnitude (dB)

Transmission Magnitude (dB)

1. Full 2-Port calibration with isolation, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. TOSLK50A-20 or TOSLKF50A-20 calibration kit. Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable. Reflection and Transmission Tracking are typical.

8 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Cable and Antenna Analyzer (continued)

Measurement Accuracy1 (TOSLK50A-40 or TOSLKF50A-40)

Frequency Range

Directivity (dB)

1 MHz to 10 GHz

 42

> 10 GHz to 20 GHz

 36

> 20 GHz to 30 GHz

 32

> 30 GHz to 40 GHz

 30

Source Match (dB)  33  26  22  20

Corrected Measurement Uncertainty (Transmission from Port 1 to Port 2)

Return Loss Magnitude Uncertainty

10

100

20 MHz - 8 GHz 8 GHz - 20 GHz 20 GHz - 30 GHz 30 GHz - 40 GHz

1

10

Site MasterTM S820E

Load Match (dB)  42  36  32  30

Reflection Tracking (dB)
±0.08 ±0.04 ±0.04 ±0.04

Transmission Tracking (dB)
±0.06 ±0.03 ±0.03 ±0.03

Return Loss Phase Uncertainty

20 MHz - 8 GHz 8 GHz - 20 GHz 20 GHz - 30 GHz 30 GHz - 40 GHz

Uncertainty (degrees)

Uncertainty (dB)

Uncertainty (dB)

0.1

1

-40

-35

-30

-25

-20

-15

-10

-5

0

-40

-35

-30

-25

-20

-15

-10

-5

0

Return Loss Magnitude (dB)

Return Loss Magnitude (dB)

Transmission Magnitude Uncertainty

10

100

20 MHz - 8 GHz

8 GHz - 14 GHz

14 GHz - 40 GHz

1

10

Transmission Phase Uncertainty

20 MHz - 8 GHz 8 GHz - 14 GHz 14 GHz - 40 GHz

Uncertainty (degrees)

0.1

1

0.01

0.1

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

Transmission Magnitude (dB)

Transmission Magnitude (dB)

1. Full 2-Port calibration with isolation, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. TOSLK50A-40 or TOSLKF50A-40 calibration kit. Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable. Reflection and Transmission Tracking are typical.

S820E TDS

PN: 11410-00749 Rev. V

9 of 28

Site MasterTM S820E

Specifications

Cable and Antenna Analyzer (continued)
External Sensor Transmission Measurement Accuracy1 (Corrected Transmission Uncertainty, Magnitude Only)

Transmission Magnitude Uncertainty
MA24108A, MA24118A, MA24126A (DUT Match = 30 dB)

10

10

10 MHz - 8 GHz

8 GHz - 18 GHz

18 GHz - 26 GHz

1

1

Transmission Magnitude Uncertainty
SC8268 (DUT Match = 30 dB)
1 MHz - 8 GHz 8 GHz - 18 GHz 18 GHz - 26 GHz 26 GHz - 40 GHz

Uncertainty (dB)

Uncertainty (dB)

0.1

0.1

-50

-45

-40

-35

-30

-25

-20

-15

-10

-5

0

-50

-45

-40

-35

-30

-25

-20

-15

-10

-5

0

Transmission Magnitude (dB)

Transmission Magnitude (dB)

Transmission Magnitude Uncertainty at 18 GHz

MA24118A, MA24126A

10

10

10 dB DUT Match

30 dB DUT Match

Transmission Magnitude Uncertainty at 18 GHz
SC8268
10 dB DUT Match 30 dB DUT Match

1

1

Uncertainty (dB)

Uncertainty (dB)

0.1

-50

-45

-40

-35

-30

-25

-20

-15

-10

-5

0

Transmission Magnitude (dB)

0.1

-50

-45

-40

-35

-30

-25

-20

-15

-10

-5

0

Transmission Magnitude (dB)

1. Sensor Transmission Calibration from Port 1 to Sensor, default power, 10 Hz bandwidth. SC8268 specifications are typical.

10 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Site MasterTM S820E

High Accuracy Power Meter (requires external USB Power Sensor)

Amplitude Average Zero/Cal Limits
Power Sensor Model Description
Frequency Range Connector
Dynamic Range
Measurand
Measurement Uncertainty Data sheet
(for complete specifications) Notes:

Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale # of Running Averages, Max Hold Zero On/Off, Cal Factor (Center Frequency, Signal Standard) Limit On/Off, Limit Upper/Lower

MA24105A

MA24106A

MA24108A/18A/26A MA24208A/18A

MA24330A/40A/50A

Inline High Power Sensor

High Accuracy RF Power Sensor

Microwave USB Power Sensor

Microwave Universal USB Power Sensor

Microwave CW USB Power Sensor

350 MHz to 4 GHz 50 MHz to 6 GHz

10 MHz to 8/18/26 GHz

10 MHz to 8/18 GHz 10 MHz to 33/40/50 GHz

Type N(f), 50 

Type N(m), 50 

Type N(m), 50  (8/18 GHz)
Type K(m), 50  (26 GHz)

Type N(m), 50 

Type K(m), 50  (33/40 GHz)
Type V(m), 50  (50 GHz)

+3 dBm to +51.76 dBm (2 mW to 150 W)

­40 dBm to

­40 dBm to

­60 dBm to

+23 dBm

+20 dBm

+20 dBm

(0.1 µW to 200 mW) (0.1 µW to 100 mW) (1 nW to 100 mW)

­70 dBm to +20 dBm (0.1 nW to 100 mW)

True-RMS ± 0.17 dBa

True-RMS ± 0.16 dBb

True-RMS, Slot Power, Burst Average Power
± 0.18 dBc

True-RMS, Slot Power, Burst Average Power
± 0.17 dBd

Average Power ± 0.17 dBe

11410-00621

11410-00424

11410-00504

11410-00841

11410-00906

a. Expanded uncertainty with K=2 for power measurements of a CW signal greater than +20 dBm with a matched load. Measurement results referenced to the input side of the sensor.
b. Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than ­20 dBm with zero mismatch errors.
c. Expanded uncertainty with K=2 for power measurements of a CW signal greater than ­20 dBm with zero mismatch errors. d. Power uncertainty expressed with two sigma confidence level for CW measurement after zero operation. Includes
calibration factor and linearity over temperature uncertainties, but not the effects of mismatch, zero set and drift, or noise. e. Includes linearity over temperature uncertainties, but not the effects of calibration factor, mismatch, zero set and drift, and
noise.

S820E TDS

PN: 11410-00749 Rev. V

11 of 28

Site MasterTM S820E

Video Inspection Probe (Requires external USB Video Inspection Probe, sold separately)

Setup Parameters
Probe Models Tip Type (included with G0306A)
Test Profile (IEC 61300-3-35) Auto Analyze
Auto Filename Auto Filename Settings

G0306A or G0306B 400X USB Visual Inspection Probe SC_APC_F:, SC_PC_F:, LC_PC_F:, FC_PC_F:, 2.5APC_M:, 2.5PC_M:, 1.25PC_M: SM PC >45:, SM APC:, SM PC >25:, MM PC 62.5:, MM PC 50.0: On/Off On/Off Location, File Prefix, Start Number, Include Date

Measurement Parameters
Live Captured
Analyze Results Table
Overlay Zoom Control Help

View Live Image Capture Image for Analysis Analyze Image Auto/Off On/Off Displays instruction for image Zoom feature

Save/Recall Parameters
Save Recall File Management

Measurement (*.vipi), VIP Image (*.png), Screen Shot (.png) Measurement (*.vipi), VIP Image (*.png), Screen Shot (.png) Rename, Create Folder, Copy, Paste, Delete

Report Parameters
Header Settings Generate Report

Customer, Project, Operator, Notes, Include Logo Generates pdf report with options to include multiple *.vipi files

Instrument Displays

Specifications

Dirty, oily fiber fails inspection

After proper cleaning, fiber passes 100%

12 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Site MasterTM S820E

Vector Network Analyzer (Option 440)

Setup Parameters
Active Trace Measurement (S Parameter)
Graph Types
Domain Number of Traces
Trace Format
Smoothing Group Delay Aperture
Group Delay Range Frequency Distance
Distance Units DTF Aid
DTF Setup Windowing Amplitude Calibration
Cal Type
Cal Line Cal Method Calibration Standards' Coefficients
Marker
Limit
Test Limits Save1
Recall2 File Management Navigation (File Management) Frequency Sweep Type
Data Points Data Averaging IF Bandwidth (Hz) Reference Plane
Auto Reference Plane Extension
Trace Memory
Trace Math Dispersion Compensation
Impedance Conversion Timebase Reference
Ethernet Configuration Languages

Tr1, Tr2, Tr3, Tr4 S11, S21, S12, S22 Log Magnitude, SWR, Phase, Unwrapped Phase, Real, Imaginary, Group Delay, Smith Chart (Impedance), Inverted Smith Chart (Admittance), Log Mag/2 (1-Port Cable Loss), Real Impedance, Imaginary Impedance Frequency Domain, Distance Domain 1, 2, 3, 4 Single, Dual, Tri, Quad. When used with Number of Traces, overlays are possible including a Single Format with Four trace overlays. Smoothing 0 % to 20 % Independent Trace based. Aperture 0.25 % to 20 % Aperture Defined as the frequency span over which the phase change is computed at a given frequency point. The aperture can be changed without recalibration. < 180º of phase change within the aperture Start Frequency (F1), Stop Frequency (F2) Start Distance (D1), Stop Distance (D2) Meters (m), Feet (ft) Provides detailed DTF resolution information based on current instrument settings. Also provides helpful tips to optimize results. DUT Line Type (Coax/WG), Cable List, Cable Loss, Propagation Velocity, Windowing Rectangular, Nominal Side Lobe, Low Side Lobe, Minimum Side Lobe Resolution Per Division, Reference Value, Reference Line, Autoscale, Scale Preset Start Calibration, Thru Update, Cal Info, Interpolation (On/Off), Cal Correction (On/Off) Full 2-Port, Full S11, Full S22, Full S11 & S22, One-Path Two-Port (S11,S21), One-Path Two-Port (S22,S12), Response S11, Response S22, Response S11 & S22, Response S21, Response S12, Response S21 & S12 Coax, Waveguide Short-Open-Load-Through (SOLT), Offset-Short (SSLT) Coax: K-Connector, N-Connector, 7/16, SMA, TNC, and four User defined Waveguide: WG11A, WG12, WG13, WG14, WG15, WG16, WG17, WG18, WG20, WG22, and four User Defined Markers 1 to 8 (On/Off), Delta Makers 2 to 8 (Ref Mk1), Marker to Peak/Valley, Marker Tracking (On/Off),4 Marker Table, Marker 5 and 7 (Peak/Valley between M1 and M2), Marker 6 and 8 (Peak/Valley between M3 and M4) Active Limit (Upper/Lower), Limit State (On/Off, Single, Segmented), Move Active Limit, Edit Segments (42 upper and 42 lower segments maximum), Limit Alarm (On/Off), Pass/Fail (On/Off), Limit Preset Pass/Fail for Upper, Pass/Fail for Lower, Limit Audible Alarm Measurement (.svna), Setup (.stp), Screen Shot (.png), S2P-Real/Imaginary (.s2p), S2P-Linear Mag/Phase (.s2p), S2P-Log Mag/Phase (.s2p), Text (.txt), CSV (.csv) Measurement (.svna), Setup (.stp), Screen Shot (.png) Rename, Create Folder, Copy, Paste, Delete Top, Bottom, Page Up, Page Down Linear Continuous, Linear Single Sweep Data Points 2 to 4001 (arbitrary setting) Sweep-by-Sweep, 1 to 1000 10, 20, 50, 100, 200, 500, 1k, 2k, 5k, 10k, 20k, 50k, 100k Reference Plane The reference planes of a calibration (or other normalization) can be changed by entering a line length or time, and loss. Assumes flat magnitude, linear phase, and constant impedance. Instead of manually entering a line length, this feature automatically adjusts phase shift from the current calibration (or other normalization) to compensate for external cables (or test fixtures). Assumes no loss (user can manually enter loss if known), flat magnitude, linear phase, and constant impedance. A separate memory for each trace can be used to store measurement data for later display. The trace data can be saved and recalled. Complex trace math operations of subtraction, addition, multiplication, or division are provided. Waveguide correction that improves accuracy of distance-to-fault data by automatically compensating for different wavelengths propagating at different speeds. Support for 50  and 75  Smith Charts are provided. Internal (default), External 10 MHz (Auto-sense, BNC female, Max +10 dBm) DHCP or Manual (Static) IP configuration, 10/100 Base-T, RJ45 jack English, French, German, Italian, Spanish, Russian, Portuguese, Japanese, Korean, Chinese

Frequency

Frequency Range Frequency Accuracy
Stability Aging
Frequency Resolution

1 MHz to 8/14/20/30/40 GHz (Frequency option dependent) ±1.0 ppm at 23 °C ±1.0 ppm from ­10 °C to +55 °C, typical ±1.0 ppm/yr, typical 1 Hz

Output Power

1 MHz to 8 GHz +5 dBm, typical (High); ­20 dBm, typical (Low) >8 GHz to 40 GHz ­3 dBm, typical (High); ­20 dBm, typical (Low)

1. SVNA (.svna) and S2P (.s2p) file formats are available in VNA Mode only. 2. SVNA (.svna) file format recall is available in VNA Mode only.

S820E TDS

PN: 11410-00749 Rev. V

13 of 28

Site MasterTM S820E

Specifications

Vector Network Analyzer (Option 440) (continued)

RF Immunity 1

RF Immunity High +17 dBm nominal

Measurement Speed 2

 550 s/pt (S11 and S21, 1001 points, 100 kHz IFBW, RF immunity low, typical)

Dynamic Range3, 4 (High Power, 10 Hz IFBW, 10 averages Port 1 to Port 2)
1 MHz to 10 MHz  85 dB (105 dB, typical) > 10 MHz to 8 GHz  100 dB (115 dB, typical) > 8 GHz to 40 GHz  100 dB (110 dB, typical)

Receiver Compression Port 1 or Port 2 (0.1 dB compression)
1 MHz to 40 GHz +5 dBm, typical
High Level Noise5 (High Power, 100 Hz IFBW, 20 MHz to 40 GHz)
Magnitude ±0.006 dB (±0.001 dB, typical) rms Phase ±0.090° (±0.060°, typical)

Temperature Stability (Typical, 10 MHz to 40 GHz, ratio measurement, ports shorted)
Magnitude ±0.02 dB/°C Phase ±0.3 degrees/°C

Log Mag

Resolution Per Division Reference Value Reference Line

0.01 to 100 dB ±1000 dB 0 to 10

Log Mag/2

Resolution Per Division Reference Value Reference Line

0.01 to 100 dB ±1000 dB 0 to 10

SWR

Resolution Per Division Reference Value Reference Line

0.01 to 100 1 to 1000 0 to 10

Phase

Resolution Per Division Reference Value Reference Line

0.01° to 90° ±1000° 0 to 10

Unwrapped Phase
Resolution Per Division Reference Value Reference Line

0.01 degrees to 1013 degrees ±1013 degrees 0 to 10

Real/Imaginary
Resolution Per Division Reference Value Reference Line

0.01 to 260 ±10000 0 to 10

Real/Imaginary Impedance
Resolution Per Division Reference Value Reference Line

0.01  to 100,000  ±100,000  0 to 10

Group Delay

Resolution Per Division Reference Value Reference Line

1 fs to 100 s ±100 s 0 to 10

Smith Chart/Inv Smith Chart
Reference Impedance 50 , 75 

1. +13 dBm for interfering signals landing in-band. 2. Single trace display, frequency domain. Excludes Group Delay, Smith, or Admittance graph types. Excludes Active Smoothing, Markers, and/or Limits. 3. Dynamic range is defined as the difference between output power and receiver noise floor. 4. Decrease specification by 5 dB between 8 GHz and 14 GHz. Crosstalk may reduce dynamic range up to 20 dB (typical) at lower IF bandwidths ( 10 kHz) when measuring highly
reflective DUT's from 4 GHz to 8 GHz. Reflection measurements are not affected. 5. High Level Noise below 20 MHz is increased by a factor of 5.0. High Level Noise (Phase only) above 20 GHz is increased by a factor of 1.5.

14 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Site MasterTM S820E

Vector Network Analyzer (Option 440) (continued)

Measurement Accuracy1 (OSLN50A-8 or OSLNF50A-8, TOSLN50A-8 or TOSLNF50A-8)

Frequency Range

Directivity (dB)

Source Match (dB)

Load Match (dB)

1 MHz to 6 GHz

 42

 33

 42

> 6 GHz to 8 GHz

 37

 33

 37

Reflection Tracking (dB)
±0.08
±0.08

Transmission Tracking (dB)
±0.06
±0.06

Transmission Uncertainty (S21, S12) (S11 = S22 = 0)

TrsmssZDeUery

10

100

20 MHz - 8 GHz

TrsmssZPhseUery

20 MHz - 8 GHz

1

10

Uery(

Uery(B)

0.1

1

0.01

0.1

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

TrsmssZDB)

TrsmssZD(B)

Reflection Uncertainty (S11, S22) (S21 = S12 = 0)

ZZDeUery

10

100

20 MHz - 6 GHz 6 GHz - 8 GHz

RZPhseUery

20 MHz - 6 GHz 6 GHz - 8 GHz

1

10

Uery(

Uery(B)

0.1

1

-40

-35

-30

-25

-20

-15

-10

-5

0

-40

-35

-30

-25

-20

-15

-10

-5

0

ZZDB)

ZZD(B)

1. Full 2-Port calibration with isolation, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. OSLN50A-8, OSLNF50A-8, TOSLN50A-8, or TOSLNF50A-8 calibration kit. Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable. Reflection and Transmission Tracking are typical.

S820E TDS

PN: 11410-00749 Rev. V

15 of 28

Site MasterTM S820E

Specifications

Vector Network Analyzer (Option 440) (continued)

Measurement Accuracy1 (OSLN50A-18 or OSLNF50A-18, TOSLN50A-18 or TOSLNF50A-18)

Frequency Range

Directivity (dB)

Source Match (dB)

Load Match (dB)

1 MHz to 6 GHz

 42

 33

 42

> 6 GHz to 9 GHz

 37

 33

 37

> 9 GHz to 18 GHz

 33

 26

 33

Reflection Tracking (dB)
±0.08 ±0.08 ±0.04

Transmission Tracking (dB)
±0.06 ±0.06 ±0.03

Transmission Uncertainty (S21, S12) (S11 = S22 = 0)

TrsmssZDeUery

10

100

20 MHz - 8 GHz

8 GHz - 14 GHz

14 GHz - 18 GHz

1

10

TrsmssZPhseUery

20 MHz - 8 GHz 8 GHz - 14 GHz 14 GHz - 18 GHz

Uery(

Uery(B)

0.1

1

0.01

0.1

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

TrsmssZDB)

TrsmssZD(B)

Reflection Uncertainty (S11, S22) (S21 = S12 = 0)

ZZDeUery

10

100

20 MHz - 6 GHz

6 GHz - 8 GHz

8 GHz - 18 GHz

RZPhseUery

20 MHz - 6 GHz 6 GHz - 8 GHz 8 GHz - 18 GHz

1

10

Uery(

Uery(B)

0.1

1

-40

-35

-30

-25

-20

-15

-10

-5

0

-40

-35

-30

-25

-20

-15

-10

-5

0

ZZDB)

ZZD(B)

1. Full 2-Port calibration with isolation, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. OSLN50A-18, OSLNF50A-18, TOSLN50A-18, or TOSLNF50A-18 calibration kit. Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable. Reflection and Transmission Tracking are typical.

16 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Vector Network Analyzer (Option 440) (continued)

Measurement Accuracy1 (TOSLK50A-20 or TOSLKF50A-20)

Frequency Range

Directivity (dB)

1 MHz to 10 GHz

 42

> 10 GHz to 20 GHz

 36

Source Match (dB)
 33
 26

Transmission Uncertainty (S21, S12) (S11 = S22 = 0)

TrsmssZDeUery

10

100

20 MHz - 8 GHz

8 GHz - 14 GHz

14 GHz - 20 GHz

1

10

Site MasterTM S820E

Load Match (dB)
 42
 36

Reflection Tracking (dB)
±0.08
±0.04

Transmission Tracking (dB)
±0.06
±0.03

TrsmssZPhseUery

20 MHz - 8 GHz 8 GHz - 14 GHz 14 GHz - 20 GHz

Uery

UeryB)

0.1

1

0.01

0.1

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

TrsmssZDB)

TrsmssZDB)

Reflection Uncertainty (S11, S22) (S21 = S12 = 0)

ZZDeUery

10

100

20 MHz - 8 GHz

8 GHz - 20 GHz

RZPhseUery

20 MHz - 8 GHz 8 GHz - 20 GHz

1

10

Uery

UeryB)

0.1

1

-40

-35

-30

-25

-20

-15

-10

-5

0

-40

-35

-30

-25

-20

-15

-10

-5

0

ZZDB)

ZZDB)

1. Full 2-Port calibration with isolation, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. TOSLK50A-20 or TOSLKF50A-20 calibration kit. Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable. Reflection and Transmission Tracking are typical.

S820E TDS

PN: 11410-00749 Rev. V

17 of 28

Site MasterTM S820E

Vector Network Analyzer (Option 440) (continued)

Measurement Accuracy1 (TOSLK50A-40 or TOSLKF50A-40)

Frequency Range

Directivity (dB)

1 MHz to 10 GHz

 42

> 10 GHz to 20 GHz

 36

> 20 GHz to 30 GHz

 32

> 30 GHz to 40 GHz

 30

Source Match (dB)  33  26  22  20

Transmission Uncertainty (S21, S12) (S11 = S22 = 0)

Transmission Magnitude Uncertainty

10

100

20 MHz - 8 GHz

8 GHz - 14 GHz

14 GHz - 40 GHz

1

10

Specifications

Load Match (dB)  42  36  32  30

Reflection Tracking (dB)
±0.08 ±0.04 ±0.04 ±0.04

Transmission Tracking (dB)
±0.06 ±0.03 ±0.03 ±0.03

Transmission Phase Uncertainty

20 MHz - 8 GHz 8 GHz - 14 GHz 14 GHz - 40 GHz

Uncertainty (degrees)

Uncertainty (dB)

0.1

1

0.01

0.1

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

Transmission Magnitude (dB)

Transmission Magnitude (dB)

Reflection Uncertainty (S11, S22) (S21 = S12 = 0)

ZZDe Uncertainty

10

100

20 MHz - 8 GHz 8 GHz - 20 GHz 20 GHz - 30 GHz 30 GHz - 40 GHz

1

10

RZ Phase Uncertainty

20 MHz - 8 GHz 8 GHz - 20 GHz 20 GHz - 30 GHz 30 GHz - 40 GHz

Uncertainty (degrees)

Uncertainty (dB)

0.1

1

-40

-35

-30

-25

-20

-15

-10

-5

0

-40

-35

-30

-25

-20

-15

-10

-5

0

ZZDdB)

ZZMagnitude (dB)

1. Full 2-Port calibration with isolation, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. TOSLK50A-40 or TOSLKF50A-40 calibration kit. Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable. Reflection and Transmission Tracking are typical.

18 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Site MasterTM S820E

Vector Voltmeter (Option 441)

Setup Parameters (Measurement)
Reflection 1-port Reflection (best for cable trimming, stub tuning, magnitude and phase matching of low loss DUTs) Transmission 2-port Transmission (best magnitude and phase matching of splitters, high loss DUTs, glide slope, etc.)
Ratio A/B Magnitude & Phase Ratio of A & B receivers. Port 1 = A, Port 2 = B. Requires external CW source Ratio B/A Magnitude & Phase Ratio of A & B receivers. Port 1 = A, Port 2 = B. Requires external CW source Measurement Format LogMag/Phase, LinMag/Phase, SWR, Impedance Display Format Single, Table (table holds up to 12 measurements plus reference) Save Reference Normalize response (Measurements become relative to saved reference) Clear Reference Clears normalized response (Measurements are no longer relative to saved reference) Clear Table Clears all values in table
Setup Parameters (Frequency)1
Measurement Frequency Set CW Frequency, 1 MHz (minimum)

Setup Parameters (Amplitude)
Resolution Reference Impedance

1 or 2 Decimal Display Resolution 50  or 75  (Impedance Measurement Format only)

Setup Parameters (Calibration)
Start Calibration Thru Update Cal Info
Cal Correction

Measure, Cal Setup Updates Thru parameters of active calibration and maintains OSL calibration parameters Display current calibration status, including temperature On/Off

Setup Parameters (Sweep)
Run/Hold RF Pwr In Hold Source Power
IFBW Sweep Averaging

Hold stops measurement and freezes display data On/Off High/Low 10 Hz, 100 Hz (default), 1 kHz, 100 kHz Range 1 to 1000 rolling average

Setup Parameters (File)
Save Recall File Management Navigation (File management)

Measurement (.vvm), Setup (.stp), Screen Shot (.png), Text (.txt), CSV (.csv) Measurement (.vvm), Setup (.stp), Screen Shot (.png) Rename, Create Folder, Copy, Paste, Delete Top, Bottom, Page Up, Page Down

Setup Parameters (System)
Timebase Reference Ethernet Configuration
Languages

Internal (default), External 10 MHz (Auto-sense, BNC female, Max +10 dBm) DHCP or Manual (Static) IP configuration, 10/100 Base-T, RJ45 connector English, French, German, Italian, Spanish, Russian, Portuguese, Japanese, Korean, Chinese

1. Reference receiver (A or B) will Auto-tune approximately ±100 kHz to lock onto external CW signal during A/B & B/A Ratio measurement.

S820E TDS

PN: 11410-00749 Rev. V

19 of 28

Site MasterTM S820E

Specifications

Vector Voltmeter (Option 441) (continued)

Frequency

Frequency Range Frequency Accuracy
Stability Aging
Frequency Resolution

Output Power1

1 MHz to 8 GHz >8 GHz to 40 GHz

1 MHz to 8/14/20/30/40 GHz (frequency option dependent) ±1.0 ppm at 23 °C ±1.0 ppm from ­10 °C to +55 °C, typical ±1.0 ppm/yr, typical 1 Hz
+5 dBm, typical (High); ­20 dBm, typical (Low) ­3 dBm, typical (High); ­20 dBm, typical (Low)

Reflection/Transmission Uncertainty

1 MHz to 40 GHz

See the uncertainty curves in the Cable and Antenna Analyzer section. Applicable only when a vector error correction (calibration) is performed and active. Uncalibrated reflection/transmission uncertainty is not specified.

Receiver Compression2 Port 1 or Port 2 (0.1 dB compression)
1 MHz to 40 GHz +5 dBm, typical

Reference Level Input Range2 (A/B and B/A)
1 MHz to 40 GHz +5 dBm to ­60 dBm (auto ranging), typical

Ratio Accuracy3 (A/B and B/A)
1 MHz to 1 GHz >1 GHz to 20 GHz >20 GHz to 40 GHz

 ±0.2 dB typical (Relative to stored reference, DUT loss <10 dB)  ±0.5 dB typical (Relative to stored reference, DUT loss <10 dB)  ±1.0 dB typical (Relative to stored reference, DUT loss <10 dB)

Measurement Format

LogMag/Phase
Resolution Magnitude Display Phase Display Range

1 or 2 decimal places dB ±180°

LinMag/Phase

Resolution Magnitude Display Phase Display Range

1 or 2 decimal places Linear ±180°

SWR

Resolution 1 or 2 decimal places Display Linear SWR

Impedance

Resolution 1 or 2 decimal places Display Real and Imaginary (complex impedance) 

1. Not applicable in A/B or B/A Ratio Measurement. 2. Recommend +3 dBm for A/B or B/A Ratio Measurement. 3. Reference signal level 0 to ­20 dBm at input port.
20 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Site MasterTM S820E

General Specifications

Setup Parameters1
System Info System Setups
Date/Time Language Display/Audio Option Configuration Connectivity Diagnostics
Preset Reset
File File Management
Save Recall Navigation Internal Trace/Setup Memory External Trace/Setup Memory

Status, Battery Date/Time, Language, Display/Audio, Option Configuration Day, Month, Year, Time English, French, German, Italian, Spanish, Russian, Portuguese, Japanese, Korean, Chinese Brightness, Color Schemes, Screen Shot Settings, Volume Enable Options Using Key and Enable Options Using File GPS (Clear Data, Sync System Time), Ethernet Configuration (DHCP/Static) Self Test Preset, Reset Factory Reset, Delete All User or Custom Files, Master Reset, Update Firmware Save, Recall, File Management Rename, Create Folder, Copy, Paste, Delete, Navigation Measurement (*.dat, *.vipi), Setup (*.stp), Screen Shot and VIP Image (*.png), Text (*.txt), CSV (*.csv) Measurement (*.dat, *.vipi), Setup (*.stp), Screen Shot and VIP Image (*.png) Top, Bottom, Page Up, Page Down >2000 files, files may be traces, setups, screen shots, or any combination Limited only by size of USB Flash drive

Connectors
Port 1 (models up to 14 GHz) Port 2 (models up to 14 GHz)
Port 1 (models > 14 GHz) Port 2 (models > 14 GHz)
External Reference In External Trigger In Headset Jack External Power USB Interface (2) USB Interface Ethernet

Type N, female, 50 , Maximum Input +23 dBm, ±50 VDC Type N, female, 50 , Maximum Input +23 dBm, ±50 VDC Type Ruggedized K, male, 50 , Maximum Input +23 dBm, ±50 VDC Type Ruggedized K, male, 50 , Maximum Input +23 dBm, ±50 VDC Type BNC female, 50 , 10 MHz, Maximum +10 dBm Type BNC female, 50 , 3.3 V or 5 V TTL triggers on positive edge. Maximum +5 VDC 3.5 mm mini-jack 5.5 mm barrel connector, +11 VDC to +14 VDC,  4.0 A Type A, Connect USB Flash Drive, GPS Module, Power Sensor, other 5-pin Mini-B, Connect to PC for data transfer and/or control RJ-45, Category 5, 10/100 MB/s. Connect to PC for data transfer and/or control

Display

Type Size Resolution Pixel Defects

High Resolution Resistive Touchscreen 8.4 in daylight viewable color LCD 800 x 600 No more than five defective pixels (99.9989% good pixels)

Battery

Type Li-Ion Battery Operation 5.0 hr, typical

Regulatory Compliance
European Union
Australia and New Zealand Canada
South Korea

EMC 2014/30/EU, EN 61326:2013, CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11 Low Voltage Directive 2014/35/EU Safety EN 61010-1:2010 RoHS Directive 2011/65/EU applies to instruments with CE marking placed on the market after July 22, 2017
RCM AS/NZS 4417:2012
ICES-1(A)/NMB-1(A)
KCC-REM-A21-0004

Environmental
Operating Temperature Range Storage Temperature Range Maximum Relative Humidity Vibration, Sinusoidal Vibration, Random Half Sine Shock Altitude Explosive Atmosphere

MIL-PRF-28800F Class 2 ­10 ºC to 55 ºC ­51 ºC to 71 ºC 95 % RH at 30 ºC, non-condensing 5 Hz to 55 Hz 10 Hz to 500 Hz 30 gn 4600 meters, operating and non-operating MIL-PRF-28800F Section 4.5.6.3 MIL-STD-810G, Method 511.5, Procedure 1

Size and Weight

Size 273 mm x 199 mm x 91 mm (10.7 in x 7.8 in x 3.6 in) Weight 3.0 kg (6.6 lb), including battery

Warranty

Duration Standard three-year warranty (one-year warranty on battery)

1. Applies to standard instruments only. Refer to specific option pages for detailed setup parameters for installed options.

S820E TDS

PN: 11410-00749 Rev. V

21 of 28

Site MasterTM S820E

Specifications

Line Sweep ToolsTM (for your PC)

Trace Capture
Browse to Instrument Open Legacy Files Open Current Files Capture Plots To

View and copy traces from the test equipment to your PC using Windows Explorer Open DAT files captured with Handheld Software Tools v6.61 Open VNA or DAT files The Line Sweep Tools screen, DAT files, Database, or JPEG

Traces

Trace Types Return Loss, VSWR, DTF-RL, DTF-VSWR, Cable Loss, Smith Chart, and PIM Trace Formats DAT, VNA, CSV, PNG, BMP, JPG, HTML, Data Base, and PDF

Report Generation
Report Generator Report Format Report Setup Trace Setup

Includes GPS location along with measurements Create reports in HTML or PDF format Report Title, Company, Prepared for, Location, Date and Time, Filename, Company logo 1 Trace Portrait Mode, 2 Trace Portrait Mode, 1 Trace Landscape Mode

Trace Validation

Presets Marker Controls
Delta Markers Limit Line
Next Trace Button

7 presets allow "one click" setting of up to 6 markers and one limit line 6 regular Markers, Marker Peak, Marker Valley, Marker between, and frequency entry 6 Delta markers Enable and drag or value entry. Also works with presets Next Trace and Previous Trace arrow keys allow quick switching between traces

Tools

Cable Editor Distance to Fault Measurement Calculator Signal Standard Editor
Renaming Grid

Allows creation of custom cable parameters Converts a Return Loss trace to a Distance to Fault trace Converts Real, Imaginary, Magnitude, Phase, RL, VSWR, Rho, and Transmit power Creates new band and channel tables 36 user definable phrases for creation of file names, trace titles, and trace subtitles

Connectivity

Connections Ethernet, USB cable, and USB memory stick

easyTest ToolsTM (for your PC)

Instrument Mode

Cable & Antenna Analyzer Mode

Commands

Display Image Recall Setup Prompt Save

Allows putting a custom image on the instrument screen Places the instrument into a known state Displays instructional messages on the instrument screen Allows automatic or manual saving of traces

Programmable Remote Control

Functionality
Programming Language Interfaces

Instrument functionality is available via remote programming. See the S820E Programming Manual for details.
Standard Commands for Programmable Instruments (SCPI)
USB, LAN

22 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications
Ordering Information (standard configuration)

Site MasterTM S820E

Part Number S820E

Description
Microwave Site Master (Requires one Frequency Option 708, 714, 720, 730, or 740)
Three Year Warranty (One year on battery)

Frequency Options (select one frequency option only)
Option Number Description
S820E-0708 1 MHz to 8 GHz, type N(f) ports
S820E-0714 1 MHz to 14 GHz, type N(f) ports
S820E-0720 1 MHz to 20 GHz, type Ruggedized K(m) ports (compatible with 3.5 mm and SMA connectors)
S820E-0730 1 MHz to 30 GHz, type Ruggedized K(m) ports (compatible with 3.5 mm and SMA connectors)
S820E-0740 1 MHz to 40 GHz, type Ruggedized K(m) ports (compatible with 3.5 mm and SMA connectors)

Instrument Options

Option Number S820E-0440 S820E-0441 S820E-0098
S820E-0099

Description
Vector Network Analyzer (VNA)
Vector Voltmeter (VVM)
Standard Calibration to ISO17025 and ANSI/NCSL Z540-1. Includes calibration certificate.
Premium Calibration to ISO17025 and ANSI/NCSL Z540-1. Includes calibration certificate, test report, and uncertainty data.

Standard Accessories (included with instrument)

Part Number Description 2000-1654-R Soft Carrying Case 71693-R Ruggedized K(f) to N(f), 2 pcs (included only with S820E-0720) 633-75 Rechargeable Li-Ion Battery 40-187-R AC-DC Adapter 806-141-R Automotive Power Adapter, 12 VDC, 60 W 2000-1691-R Stylus with Coiled Tether 2000-1797-R Screen Protector Film (one factory installed, one spare) 3-2000-1498 USB A/5-pin Mini-B Cable, 3.05 m (10 ft) 2000-1371-R Ethernet Cable, 2.13 m (7 ft) Certificate of Calibration and Conformance

Documentation (available at www.anritsu.com)
Optional Accessories
Miscellaneous Accessories

Part Number Description 10100-00065 Product Information, Compliance, and Safety 11410-00749 Technical Data Sheet 10580-00343 User Guide 10580-00344 Programming Manual 10580-00345 Maintenance Manual
Part Number Description 2000-1723-R High Performance USB Mag-Mount GPS Antenna/Receiver 2000-1374-R External Charger for Li-lon Batteries 67135 Anritsu Backpack (For Handheld Instrument and PC) 760-243-R Large Transit Case with Wheels and Handle 760-286-R Compact Transit Case with Wheels and Handle 55.6 cm x 35.5 cm x 22.9 cm (21.89" x 13.98" x 9.01")

S820E TDS

PN: 11410-00749 Rev. V

23 of 28

Site MasterTM S820E

Specifications

Optional Accessories (continued)
USB Power Sensors and Transmission Sensors (for complete ordering information, see the respective data sheets of each sensor)
Model Number Description
MA24105A Inline Peak Power Sensor, 350 MHz to 4 GHz, +3 dBm to +51.76 dBm MA24106A RF USB Power Sensor and 2-Port Loss/Transmission Sensor,
50 MHz to 6 GHz, +23 dBm to ­40 dBm MA24108A Microwave USB Power Sensor and 2-Port Loss/Transmission Sensor,
10 MHz to 8 GHz, +20 dBm to ­40 dBm MA24118A Microwave USB Power Sensor and 2-Port Loss/Transmission Sensor,
10 MHz to 18 GHz, +20 dBm to ­40 dBm MA24126A Microwave USB Power Sensor and 2-Port Loss/Transmission Sensor,
10 MHz to 26 GHz, +20 dBm to ­40 dBm MA24208A Microwave Universal USB Power Sensor and 2-Port Loss/Transmission
Sensor, 10 MHz to 8 GHz, +20 dBm to ­60 dBm MA24218A Microwave Universal USB Power Sensor and 2-Port Loss/Transmission
Sensor, 10 MHz to 18 GHz, +20 dBm to ­60 dBm MA24330A Microwave CW USB Power Sensor and 2-Port Loss/Transmission Sensor,
10 MHz to 33 GHz, +20 dBm to ­70 dBm MA24340A Microwave CW USB Power Sensor and 2-Port Loss/Transmission Sensor,
10 MHz to 40 GHz, +20 dBm to ­70 dBm MA24350A Microwave CW USB Power Sensor and 2-Port Loss/Transmission Sensor,
10 MHz to 50 GHz, +20 dBm to ­70 dBm SC8268 USB Transmission Sensor, K(m), 1 MHz to 40 GHz, +10 dBm to ­50 dBm
MA25100A RF Power Indicator

USB Extender Kit (for use with external 2-port cable loss/transmission sensors; requires Cat 5e extension cable, sold separately)
Model Number Description 2000-1717-Ra USB 1.1 Passive 40 m Extender
2000-1900-R USB 2.0 Active 100 meter Extender (with Type A power cord for USA, Japan, North America, Central America and Caribbean)
2000-1901-R USB 2.0 Active 100 meter Extender (with Type C power cord for use in Europe, India, South Korea, and many countries in Middle East and Africa)
2000-1902-R USB 2.0 Active 100 meter Extender (with Type I power cord for use in Australia, New Zealand, Argentina, and the South Pacific)
2000-1903-R USB 2.0 Active 100 meter Extender (with Type G power cord for use in the UK, and several other countries in Asia, the Middle East, and Africa)
2100-28-R Cat 5e extension cable for use with USB Extender (22.5 m)
a. Not compatible with sensors MA24208A, MA24218A, MA24330A, MA24340A, MA24350A; must use active extenders with these sensors.

Video Inspection Probe

Part Number G0306B
Universal Tips Bulkhead Tips

Description
Video Inspection Probe (400x), including the following standard connector tips: H0361A 1.25PC-M, H0360A 2.5PC-M, H0362A 2.5APC-M H0363A LC-PC-F, H0364A FC-PC-F, H0375A ST-PC-F, H0366A SC-APC-F

Additional Tips H0372A E2000-PC-F, H0373A FC-APC-F, H0374A MU-PC-F, H0365A SC-PC-F, H0376A 1.25APC-M

Accessories:
971-14-R 971-15-R 971-16-R

Ferrule Cleaner, 2.5 mm SC Ferrule Cleaner, 1.25 mm LC Fiber Ferrule Cleaner

24 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications

Site MasterTM S820E

Optional Accessories (continued)
Full Temperature Coaxial Calibration Kits (­10 °C to +55 °C , K Type is compatible with 3.5 mm and SMA connectors
see individual data sheets on www.anritsu.com) Part Number Description OSLN50A-8 High Performance Type N(m), DC to 8 GHz, 50  OSLNF50A-8 High Performance Type N(f), DC to 8 GHz, 50  TOSLN50A-8 High Performance with Through Type N(m), DC to 8 GHz, 50  TOSLNF50A-8 High Performance with Through Type N(f), DC to 8 GHz, 50  OSLN50A-18 High Performance Type N(m), DC to 18 GHz, 50  OSLNF50A-18 High Performance Type N(f), DC to 18 GHz, 50  TOSLN50A-18 High Performance with Through Type N(m), DC to 18 GHz, 50  TOSLNF50A-18 High Performance with Through Type N(f), DC to 18 GHz, 50  TOSLK50A-20 High Performance with Through Type K(m), DC to 20 GHz, 50  TOSLKF50A-20 High Performance with Through Type K(f), DC to 20 GHz, 50  TOSLK50A-40 High Performance with Through Type K(m), DC to 40 GHz, 50  TOSLKF50A-40 High Performance with Through Type K(f), DC to 40 GHz, 50 

Coaxial Calibration Components, N Type 50 , K Type 50  (K Type is compatible with 3.5 mm and SMA connectors)
Part Number Description 22N50 Precision Open/Short, N(m), DC to 18 GHz, 50  22NF50 Precision Open/Short, N(f), DC to 18 GHz, 50 
28N50-2 Precision Load, N(m), DC to 18 GHz, 50  28NF50-2 Precision Load, N(f), DC to 18 GHz, 50 
22K50 Precision Open/Short, K(m), DC to 40 GHz, 50  22KF50 Precision Open/Short, K(f), DC to 40 GHz, 50  28K50 Precision Load, K(m), DC to 40 GHz, 50  28KF50 Precision Load, K(f), DC to 40 GHz, 50 

Coaxial Calibration Components, Other 50 , 75 
Part Number Description 2000-1618-R Open/Short/Load, 7/16 DIN(m), DC to 6.0 GHz 50  2000-1619-R Open/Short/Load, 7/16 DIN(f), DC to 6.0 GHz 50  2000-1914-R Precision Open/Short/Load, 4.3-10(f), DC to 6 GHz, 50  2000-1915-R Precision Open/Short/Load, 4.3-10(m), DC to 6 GHz, 50  12N50-75B Matching Pad, DC to 3 GHz, 50  to 75  22N75 Open/Short, N(m), DC to 3 GHz, 75  22NF75 Open/Short, N(f), DC to 3 GHz, 75  26N75A Precision Termination, N(m), DC to 3 GHz, 75  26NF75A Precision Termination, N(f), DC to 3 GHz, 75  1091-55-R Open, TNC(f), DC to 18 GHz 1091-53-R Open, TNC(m), DC to 18 GHz 1091-56-R Short, TNC(f), DC to 18 GHz 1091-54-R Short, TNC(m), DC to 18 GHz 1015-54-R Termination, TNC(f), DC to 18 GHz 1015-55-R Termination, TNC(m), DC to 18 GHz

S820E TDS

PN: 11410-00749 Rev. V

25 of 28

Site MasterTM S820E

Specifications

Optional Accessories (continued)

Waveguide Calibration Components, Rectangular Type 50 

Coax to

Frequency

Waveguide

Range (GHz)

1/8 Offset

3/8 Offset

Termination

Adapter

3.95 to 5.85

23UA187-R

24UA187-R

26UA187-R

35UA187N-R

5.85 to 8.20

23UA137-R

24UA137-R

26UA137-R

35UA137N-R

7.05 to 10.00

23UA112-R

24UA112-R

26UA112-R

35UA112N-R

8.20 to 12.40

23UA90-R

24UA90-R

26UA90-R

35UA90N-R

12.40 to 18.00 17.00 to 26.50 26.50 to 40.00
3.30 to 4.90 3.95 to 5.85 5.85 to 8.20 7.05 to 10.00 8.20 to 12.40 10.00 to 15.00 12.40 to 18.00 17.00 to 26.50 26.50 to 40.00

23UA62-R 23UA42-R 23UA28-R 23UM40-R 23UM48-R 23UM70-R 23UM84-R 23UM100-R 23UM120-R 23UM140-R 23UM220-R 23UM320-R

24UA62-R 24UA42-R 24UA28-R 24UM40-R 24UM48-R 24UM70-R 24UM84-R 24UM100-R 24UM120-R 24UM140-R 24UM220-R 24UM320-R

26UA62-R 26UA42-R 26UA28-R 26UM40-R 26UM48-R 26UM70-R 26UM84-R 26UM100-R 26UM120-R 26UM140-R 26UM220-R 26UM320-R

35UA62N-R 35UA42K-R 35UA28K-R 35UM40N-R 35UM48N-R 35UM70N-R 35UM84N-R 35UM100N-R 35UM120N-R 35UM140N-R 35UM220K-R 35UM320K-R

Compatible Flanges CPR187F-R, CPR187G-R, UG-1352/U-R, UG-1353/U-R, UG-1728/U-R, UG-1729/U-R, UG-148/U-R, UG-149A/U-R CPR137F-R, CPR137G-R, UG-1356/U-R, UG-1357/U-R, UG-1732/U-R, UG-1733/U-R, UG-343B/U-R, UG-344/U-R, UG-440B/U-R, UG-441/U-R CPR112F-R, CPR112G-R, UG-1358/U-R, UG-1359/U-R, UG-1734/U-R, UG-1735/U-R, UG-52B/U-R, UG-51/U-R, UG-137B/U-R, UG-138/U-R CPR90F-R, CPR90G-R, UG-1360/U-R, UG-1361/U-R, UG-1736/U-R, UG-1737/U-R, UG-40B/U-R, UG-39/U-R, UG-135/U-R, UG-136B/U-R UG-541A/U-R, UG-419/U-R, UG-1665/U-R, UG1666/U-R UG-596A/U-R, UG-595/U-R, UG-597/U-R, UG-598A/U-R UG-599/U-R PDR40-R CAR48-R, PAR48-R, UAR48-R, PDR48-R CAR70-R, PAR70-R, UAR 70-R, PDR70-R CBR84-R, UBR84-R, PBR84-R, PDR84-R CBR100-R, UBR100-R, PBR100-R, PDR100-R CBR120-R, UBR120-R, PBR120-R, PDR120-R CBR140-R, UBR140-R, PBR140-R, PDR140-R CBR220-R, UBR220-R, PBR220-R, PDR220-R UBR320-R

Phase-Stable Test Port Extension Cables (Armored and Flexible)

Part Number Description

14RKFKF50-0.6 0.6 m (24 in), DC to 40 GHz, Ruggedized K(f) to K(f), 50 

14RKFKF50-1.0 1.0 m (39 in), DC to 40 GHz, Ruggedized K(f) to K(f), 50 

14RKFK50-0.6 0.6 m (24 in), DC to 40 GHz, Ruggedized K(f) to K(m), 50 

14RKFK50-1.0 1.0 m (39 in), DC to 40 GHz, Ruggedized K(f) to K(m), 50 

14KFKF50-0.6 0.6 m (24 in), DC to 40 GHz, K(f) to K(f), 50 

14KFKF50-1.0 1.0 m (39 in), DC to 40 GHz, K(f) to K(f), 50 

14KFK50-0.6 0.6 m (24 in), DC to 40 GHz, K(f) to K(m), 50 

14KFK50-1.0 1.0 m (39 in), DC to 40 GHz, K(f) to K(m), 50 

15NN50-1.0B 1.0 m (39 in), DC to 18 GHz, N(m) to N(m), 50 

15NNF50-1.0B 1.0 m (39 in), DC to 18 GHz, N(m) to N(f), 50 

15LL50-1.0A 1.0 m (39 in), DC to 20 GHz, 3.5 mm(m) to 3.5 mm(m), 50 

15LLF50-1.0A 1.0 m (39 in), DC to 20 GHz, 3.5 mm(m) to 3.5 mm(f), 50 

15KK50-1.0A 1.0 m (39 in), DC to 26.5 GHz, K(m) to K(m), 50 

15KKF50-1.0A 1.0 m (39 in), DC to 26.5 GHz, K(m) to K(f), 50 

15N43M50-1.5C Test Port Extension Cable, Armored, 1.5 meters, DC to 6GHz, N(m) to 4.3-10(m)

15N43F50-1.5C

Test Port Extension Cable, Armored, 1.5 meter, DC to 6GHz, N(m) to 4.3-10(f)

15N43M50-3.0C

Test Port Extension Cable, Armored, 3 meters, DC to 6 GHz, N(m) to 4.3-10(m)

15N43F50-3.0C

Test Port Extension Cable, Armored, 3 meters, DC to 6 GHz, N(m) to 4.3-10(f)

Phase-Stable 18 GHz and 40 GHz Semi-Rigid Cables (Armored)
3670K50-1 0.3 m (12 in), DC to 40 GHz, K(f) to K(m), 50  3670K50-2 0.6 m (24 in), DC to 40 GHz, K(f) to K(m), 50  3670N50-1 0.3 m (12 in), DC to 18 GHz, N(f) to N(m), 50  3670NN50-1 0.3 m (12 in), DC to 18 GHz, N(m) to N(m), 50  3670N50-2 0.6 m (24 in), DC to 18 GHz, N(f) to N(m), 50  3670NN50-2 0.6 m (24 in), DC to 18 GHz, N(m) to N(m), 50 

26 of 28

PN: 11410-00749 Rev. V

S820E TDS

Specifications
Optional Accessories (continued)
Adapters
Precision Adapters Attenuators N Type (up to 18 GHz) Attenuators K Type (up to 40 GHz)

Site MasterTM S820E

71693-R DC to 18 GHz, Ruggedized adapter, K(f) - N(f), 50  510-90-R DC to 7.5 GHz, 7/16 (f) to N(m), 50  510-91-R DC to 7.5 GHz, 7/16 (f) to N(f), 50  510-92-R DC to 7.5 GHz, 7/16 (m) to N(m), 50  510-93-R DC to 7.5 GHz, 7/16 (m) to N(f), 50  510-96-R DC to 7.5 GHz, 7/16 DIN(m) to 7/16 DIN(m), 50  510-97-R DC to 7.5 GHz, 7/16 DIN(f) to 7/16 DIN(f), 50  510-102-R DC to 11 GHz, N(m)-N(m), 90 degrees, 50  513-62-R DC to 18 GHz, TNC(f) to N(f), 50  1091-26-R DC to 18 GHz, N(m) to SMA(m), 50  1091-27-R DC to 18 GHz, N(m) to SMA(f), 50  1091-80-R DC to 18 GHz, N(f) to SMA(m), 50  1091-81-R DC to 18 GHz, N(f) to SMA(f), 50  1091-172-R DC to 1.3 GHz, BNC(f) to N(m), 50  1091-315-R DC to 18 GHz, TNC(m) to N(f), 50  1091-317-R DC to 18 GHz, TNC(m) to SMA(f), 50  1091-318-R DC to 18 GHz, TNC(m) to SMA(m), 50  1091-323-R DC to 18 GHz, TNC(m) to TNC(f), 50  1091-324-R DC to 18 GHz, TNC(f) to N(m), 50  1091-325-R DC to 18 GHz, TNC(m) to N(m), 50  1091-326-R DC to 18 GHz, TNC(m) to TNC(m), 50  1091-465-R DC to 6 GHz, 4.3-10(f) to N(f), 50  1091-467-R DC to 6 GHz, 4.3-10(m) to N(f), 50 

34NN50A Precision Adapter, N(m) to N(m), DC to 18 GHz, 50  34NFNF50 Precision Adapter, N(f) to N(f), DC to 18 GHz, 50 
K220B Precision Adapter, DC to 40 GHz, K(m) to K(m), 50  K222B Precision Adapter, DC to 40 GHz, K(f) to K(f), 50  K224B Precision Adapter, DC to 40 GHz, K(m) to K(f), 50 

3-1010-122 20 dB, 5 W, DC to 12.4 GHz, N(m) to N(f) 42N50-20 20 dB, 5 W, DC to 18 GHz, N(m) to N(f)
42N50A-30 30 dB, 5 W, DC to 18 GHz, N(m) to N(f) 3-1010-123 30 dB, 50 W, DC to 8.5 GHz, N(m) to N(f) 1010-127-R 30 dB, 150 W, DC to 3 GHz, N(m) to N(f) 3-1010-124 40 dB, 100 W, DC to 8.5 GHz, N(f) to N(m), Uni-directional 1010-121-R 40 dB, 100 W, DC to 18 GHz, N(f) to N(m), Uni-directional 1010-128-R 40 dB, 150 W, DC to 3 GHz, N(m) to N(f)

41KB-3 41KB-6 41KB-10 41KB-20 41KC-3 41KC-6 41KC-10 41KC-20

Precision Fixed Attenuator, K(m) to K(f), 3 dB, DC to 26.5 GHz, 50  Precision Fixed Attenuator, K(m) to K(f), 6 dB, DC to 26.5 GHz, 50  Precision Fixed Attenuator, K(m) to K(f), 10 dB, DC to 26.5 GHz, 50  Precision Fixed Attenuator, K(m) to K(f), 20 dB, DC to 26.5 GHz, 50  Precision Fixed Attenuator, K(m) to K(f), 3 dB, DC to 40 GHz, 50  Precision Fixed Attenuator, K(m) to K(f), 6 dB, DC to 40 GHz, 50  Precision Fixed Attenuator, K(m) to K(f), 10 dB, DC to 40 GHz, 50  Precision Fixed Attenuator, K(m) to K(f), 20 dB, DC to 40 GHz, 50 

S820E TDS

PN: 11410-00749 Rev. V

27 of 28

Training at Anritsu
Anritsu has designed courses to help you stay up to date with technologies important to your job. For available training courses, visit: www.anritsu.com/training

· United States
Anritsu Americas Sales Company 450 Century Parkway, Suite 190 Allen, TX 75013, U.S.A. Phone: +1-800-Anritsu (1-800-267-4878)
· Canada
Anritsu Electronics Ltd. 700 Silver Seven Road, Suite 120 Kanata, Ontario K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006
· Brazil
Anritsu Eletronica Ltda. Praça Amadeu Amaral, 27 - 1 Andar 01327-010 - Bela Vista - Sao Paulo - SP Brazil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940
· Mexico
Anritsu Company, S.A. de C.V. Blvd Miguel de Cervantes Saavedra #169 Piso 1, Col. Granada Mexico, Ciudad de Mexico, 11520, MEXICO Phone: +52-55-4169-7104
· United Kingdom
Anritsu EMEA L td. 200 Capability Green Luton, Bedfordshire, LU1 3LU, U.K. Phone: +44-1582-433200 Fax: +44-1582-731303
· France
Anritsu S.A. 12 avenue du Québec, Bâtiment Iris 1- Silic 612, 91140 Villebon-sur-Yvette, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65
· Germany
Anritsu GmbH Nemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55
· Italy
Anritsu S.r.l. Via Elio Vittorini 129, 00144 Roma, Italy Phone: +39-6-509-9711 Fax: +39-6-502-2425
List Revision Date: 20200602

· Sweden
Anritsu AB Isafjordsgatan 32C 164 40 Kista, Sweden Phone: +46-8-534-707-00
· Finland
Anritsu AB Teknobulevardi 3-5 FI-01530 Vantaa, Finland Phone: +358-20-741-8100 Fax: +358-20-741-8111
· Denmark
Anritsu A/S c/o Regus Winghouse, Ørestads Boulevard 73, 4th floor, 2300 Copenhagen S, Denmark Phone: +45-7211-2200
· Russia
Anritsu EMEA Ltd. Representation Office in Russia Tverskaya str. 16/2, bld. 1, 7th floor Moscow 125009, Russia Phone: +7-495-363-1694 Fax: +7-495-935-8962
· Spain
Anritsu EMEA Ltd. Representation Office in Spain Paseo de la Castellana, 141. Planta 5, Edificio Cuzco IV 28046, Madrid, Spain Phone: +34-91-572-6761
· United Arab Emirates
Anritsu EMEA Ltd. Dubai Liaison Office 902 Aurora Tower P O Box: 500311- Dubai Internet City Dubai, United Arab Emirates Phone: +971-4-3758479 Fax: +971-4-4249036
· India
Anritsu India Private Limited 6th Floor, Indiqube ETA, No.38/4 Adjacent to EMC2, Doddanekundi, Outer Ring Road Bengaluru 560048, India Phone: +91-80-6728-1300 Fax: +91-80-6728-1301

· Singapore
Anritsu Pte. Ltd. 11 Chang Charn Road, #04-01, Shriro House Singapore 159640 Phone: +65-6282-2400 Fax: +65-6282-2533
· P.R. China (Shanghai)
Anritsu (China) Co., Ltd. Room 2701-2705, Tower A New Caohejing International Business Center No. 391 Gui Ping Road Shanghai 200233, P.R. China Phone: +86-21-6237-0898 Fax: +86-21-6237-0899
· P.R. China (Hong Kong)
Anritsu Company Ltd. Unit 1006-7, 10/F. Greenfield Tower, Concordia Plaza No. 1 Science Museum Road Tsim Sha Tsui East, Kowloon Hong Kong, P.R. China Phone: +852-2301-4980 Fax: +852-2301-3545
· Japan
Anritsu Corporation 8-5, Tamura-cho, Atsugi-shi, Kanagawa, 243-0016 Japan Phone: +81-46-296-6509 Fax: +81-46-225-8352
· South Korea
Anritsu Corporation, Ltd. 5FL, 235 Pangyoyeok-ro Bundang-gu, Seongnam-si Gyeonggi-do 13494, South Korea Phone: +82-31-696-7750 Fax: +82-31-696-7751
· Australia
Anritsu Pty. Ltd. Unit 20, 21-35 Ricketts Road Mount Waverley, Victoria 3149, Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255
· Taiwan
Anritsu Company Inc. 7F, No. 316, Sec. 1, NeiHu Rd. Taipei 114, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817

Data subject to change without notice. For the most recent specifications, visit: www.anritsu.com. 28 28 of 28

Site MasterTM S820E TDS, PN: 11410-00749, Rev. V Copyright August 2020 Anritsu Company, USA. All Rights Reserved. ® Anritsu All trademarks are registered trademarks of their respective companies. Anritsu utilizes recycled paper and environmentally conscious inks and toner.


Acrobat Distiller 11.0 (Windows)