Instructions for inovelli models including: inovelli, LZW30-SN, Switch

LZW30-SN | On/Off Switch Red S ki n

The more devices, the more stable the network. The purpose of this portion of the manual is to help you understand how Z-Wave works (in layman’s terms) as well as help you organize an efficient Z-Wave network, setting you up for success in the long run. Afterall, we’re assuming you’ll want more than one smart home device!

instructions for your HUB (NOTE: If you don’t see your HUB, please scan the, “Other” QR Code). As you can imagine, it’s hard to keep written instructions up to date with all the HUB/App changes, so the most recent instructions will be on the site. However, if you’re a manual guy/gal, we get it, please see Page 7 for more details!

Not Your Device? Search For Manuals / Datasheets:

File Info : application/pdf, 12 Pages, 1.18MB

Document
LZW30-SN Manual
LZW30-SN|On/OffSwitchRedS i
Thank You. Thankyoufortakingthechanceonus.Wearetrulyhumbledtobeapartofyoursmarthomejourneyandknowthatoutofthe manycompaniesoutthere,youtrustedustomakeyourlifesimplerandwedon'ttakethatforgranted.Ourmissionistoprovide thebestproducts,withthebestcustomersupport,atthebestprices.Sure,everycompanysaysthat...butwe'dliketothinkwe're different.Why?Well,becausewehaveourownsmarthomes,withourowndesirestomakeourlifesimplerthroughhome automation.Wewakeupeverydaytolightsturningontodifferentcolorsbasedontheweather,coffeeautomaticallybrewing beforeweleaveforwork,andthethermostatchangingbasedonourschedules.Wetakeournerdinessseriouslybyengagingin onlinegroupsanddesignourproductsaroundcommunitysuggestionsandneeds.Wedon'tpretendtobeamulti-billiondollar corporationworriedaboutshareholdersandbottom line.We'reokwithbeingthelittleguy.Theunderdog,lookingoutforthebest interestsofpeoplelikeus...theeverydaysmarthomeenthusiastwhoispassionateaboutmovingtheindustryforwardandwe wouldn'thaveitanyotherway.Soagain,from thebottom ofourhearts,thankyoufortrustingus.

TableofContents: AboutZ-Wave&RangeEstimatorTool Z-WaveDistanceWorksheet&BestPracticesforInstallation WiringDisclaimers SwitchInstallation:Single-Pole&3-Way(AuxSwitch)Installation SwitchInstallation:3-WayInstallation(DumbSwitch)Installation GettingtoKnowYourSwitch(LZW30-SN)&GeneralInclusionInstructions SmartThingsInclusionProcess SwitchConfiguration:Overview&Logic SwitchParametersandCheatCodes FCC,WarrantyandZ-WaveInformation ProjectLightsOut

Page: 2 3 4 5 6 7 8 9 10 11 12

Z-WaveSmartStart ThisdevicesupportsZ-Wave'snewSmartStartfeature.PleasedonotthrowoutthecardwithintheboxthathasyouruniqueQR CodewithyourDSK(DeviceSpecificKey).ThisQRCodecanalsobefoundonthefrontoftheswitch(metalplate)andbox.

HUB Installation Instructions. AllHUB'saredifferent,sowhyshouldyourinstallationinstructionsbethesame?Belowyou'llfindaQRCodetospecific instructionsforyourHUB(NOTE:Ifyoudon'tseeyourHUB,pleasescanthe,"Other"QRCode).Asyoucanimagine,it'shardto keepwritteninstructionsuptodatewithalltheHUB/Appchanges,sothemostrecentinstructionswillbeonthesite.However,if you'reamanualguy/gal,wegetit,pleaseseePage7formoredetails!Ifeveryourunintoanyissues,pleasereachouttousat: contact@inovelli.com.

SmartThings

Wink

Hubitat

Other

inovelli.com/lzw30-sn/setup/#smartthings

inovelli.com/lzw30-sn/setup/#wink

inovelli.com/lzw30-sn/setup/#hubitat

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

inovelli.com/lzw30-sn/setup/#other
page 1

LZW30-SN|On/OffSwitchRedS i

AboutZ-Wave.
Z-Waveisanincredibletechnology.Withitpoweringyourhome,youcanchoosefrom over600companiesand2100products, allofwhichwillworkwitheachother.Themoredevices,themorestablethenetwork.Thepurposeofthisportionofthemanual istohelpyouunderstandhowZ-Waveworks(inlayman'sterms)aswellashelpyouorganizeanefficientZ-Wavenetwork,setting youupforsuccessinthelongrun.Afterall,we'reassumingyou'llwantmorethanonesmarthomedevice!

Z-WaveNetwork|UsingDevicesThatRepeatSignals.
Asreferencedintheintro,Z-Wavecanbeusedwithafewdevicesoritcanbeusedtobuildalargenetwork.Belowyou'llseetwo examples.Inthefirstexample,auserhasaHUBwhichislookingforZ-Wavedeviceswithinitsradius.Z-Wavedevicesoutside thisradiuswillnotbefoundandneedtoeitherbemovedwithintheradiusorusearepeatingdevicetoreachit.Thesecond exampleshowshowarepeatercanbeusedtoreachadeviceoutsideoftheinitialradius.Keepthisinmindwhenbuildingyour ownnetworkandmakesuretousetherangeestimatorbelow.

Example1: SwitchBisoutofrange andwillnotworkunless eithertheHUBismoved oraZ-Waverepeateris installed.

HUB YourZ-WaveEnabledHUB A InovelliSwitch#1 B InovelliSwitch#2

Example2: Switch B is now in range becauseofSwitchCwhich isactingasaZ-Wave signalrepeater.

HUB YourZ-WaveEnabledHUB A InovelliSwitch#1 B InovelliSwitch#2 C InovelliSwitch#3

B

B

C

Dining Room

Kitchen

Garage

Dining Room

Kitchen

Garage

Living Room

HUB Man Cave
A
FrontPorch

Z-WaveOriginalRange

Living Room

HUB Man Cave
A
FrontPorch

Z-WaveExtendedRange

Z-WaveRangeEstimator.
PleaseusethebelowinformationtodeterminethedepreciationoftheZ-Wavesignal.Z-Wavedevicesshouldhaveadistanceof approximately100m (328ft)withoutanyobstaclesintheway.Usingthebelowinformation,ifasignalhastotravelthroughan innerwall,itwillloseapproximately40% ofitssignal.Therefore,100m multipliedby(100% -40%)=60m (197ft).Dothisforevery wall,window,etcandyouwillhaveyourapproximation.There'saworksheetonPage3thatwillhelp.Asalways,thisisjustan estimate.Dependingonthemanufacturer'squalityforyourotherZ-Waveproducts,yoursignalmayvary.

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 2

LZW30-SN|On/OffSwitchRedS i

Z-WaveRangeWorksheet.
FeelfreetousethebelowworksheettogiveanestimateonwhereyoucanputyourZ-WaveSwitchrelativetoyourHUB(or otherZ-Waverepeater).Belowisanexampleofhowtousethesheet,using,"Example1"from Page2.

Example#1--OriginalZ-WaveRange

Basedontheexample charttotheright,you canseethat,"SwitchB"is out of range as the signal would only reach to about thediningroom.

HUB YourZ-WaveEnabledHUB A InovelliSwitch#1 B InovelliSwitch#2

B

Dining Room

Kitchen

Garage

ForthestartingDistance,use100m.Thenlookdirectly from yourHUBtowhereveryou'dliketoputtheoutlet andseewhatobstaclesareintheway.Thenlistthose obstaclesontheworksheetbelow(usingthecharts from Page2).

Living Room

HUB Man Cave
A
FrontPorch

Z-WaveOriginalRange

BestPracticesforPairingyourLZW30-SN-On/OffSwitch Nowthatyou'vereadhowtocalculatetheZ-Waverangeandhavedeterminedthebestlocationtoputyourswitch,it'simportant tounderstandsomebestpracticesofhowtopairthisdevice.Belowareafewthingstokeepinmindwhenyoustartyour individualized pairing instructions (Pages 7-8).
CalculatetheMaximum DistanceFrom theWorksheetAboveandPlaceWellWithinThatDistance Pleaseusetheworksheetabovetocalculateyourmaximum distance.Thiswillsaveusboththeheadacheofofflinedevices. Remembertoaddallobjectsthatcouldpotentiallybeinthewayandit'sourrecommendationtobeconservativewiththe distancenumbers.
RunaZ-WaveRefreshAfterSuccessfullyPairing/Including(Optional) Whenyouhavesuccessfullypaired/includedyourdevice,it'simportanttoruna"Z-WaveRefresh"onyournetwork.Insummary, yourHUB/GatewayassignsaNodeIDtoeverysingleZ-WavedeviceandcatalogsthoseNodeID'sintoatabletoaccesslater whenit'ssending/receivinginformationfrom each.ItcatalogswhereeachNodeIDisandwhatneighborsithasarounditsothat thetrasmissionsignalsareefficient.Runninga,"Z-WaveRefresh"willtelltheHUBtore-catalogthevariousdevices(NodeID's) andupdatewhereeachdeviceisto,again,optimizethetransmissionpath.Thereasonwhythisisoptionalisbecauseyour HUB/Gatewayshouldautomaticallyrunarefreshwhenthedeviceisadded,butwe'rerecommendingitjustincaseitdoesn't.

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 3

LZW30-SN|On/OffSwitchRedS i

CAUTION-PLEASEREAD!
Thisdevice(LZW30-SN)isintendedforinstallationin accordancewiththeNationalElectricCodeandlocal regulationsintheUnitedStates,ortheCanadianElectrical CodeandlocalregulationsinCanada.Ifyouareunsureor uncomfortableaboutperformingthisinstallationconsulta qualified electrician.

CONTROLLING APPLIANCES & MOTORS
ThesedimmingswitchesareNOTmeanttocontrol appliances.Pleaseonlyusetheseforcontrollinglights.
Inaddition,pleaseDO NOTUSETO CONTROLFANSasit willruinyourfan'smotor.Theseswitchesarenotbuiltto controlafanoranymotor.

OTHER WARNINGS
RiskofFire RiskofElectricalShock RiskofBurns

MEDICALEQUIPMENT
PleaseDO NOTusethisswitchtocontrolMedicalorLife Supportequipment.Z-Wavedevicesshouldneverbeused tocontroltheOn/OffstatusofMedicaland/orLife Supportequipment.

WARNING-SHOCKHAZARD
TURNOFFTHEPOWERtothecircuitfortheswitchand lightingfixtureattheservicepanel(circuitbreaker)priorto installation.
AllwiringconnectionsmustbemadewiththePOWEROFF toavoidpersonalinjuryand/ordamagetotheswitch.
USINGMULTIPLESWITCHES
Themetalplatessurroundingtheswitchassemblyarea heatsink.Themaximum loadrating(600W)isapplicable wheninstalledinasinglegangboxwithallsix(6)tabsstillin tact(Seenumbers1-6onFigure1.1).Toinstallmultiple switchesinagangboxpleaseremovethetabsonthe outside.Thiscanbedonebyremovingeithertheleftand/or rightsidesbyusingneedle-nosepliers(clampontothetabs andwigglebackandforthuntilthetabsbreakoff).
Pleasesee,"MaxWattageKey"formaxwattagebasedon removingthetabs.

MAXWATTAGEKEY
Thisswitchisdesignedforuse onlywithpermanentlyinstalled fixtures.

Ifyouareinstallingmultiplesmart

switchesinagangbox,youwill

1

4

havetoremovetheheatsinktabs

(#'s1-6showninFigure1.1).Doing

sowillhavenoeffectonthe

2 overallperformanceoftheswitch.

5

Unlikethedimmer,theOn/Off

does not use the heat sink tabs to

dissipateheat,sotheremovalof them willhavenoimpactonthe

3

6

switch.

Figure 1.1

PLEASENOTE:Asof05/25/19,weareunabletoprovideelectricaland/orwiringadviceoutsideofourschematics.Ifyouare unabletoreadaschematicorarenotfamiliarwithwiring,wesuggesthiringanelectrician.Weapologizeforanyinconvenience.

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 4

LZW30-SN|On/OffSwitchRedS i

WiringInstructions:InstallationInaSinglePoleor3-Way(Aux)Setting(QuickNotes)
Pleaseusethispageforasinglepoleinstallationorifyou'dliketouseanauxiliary(add-on)switch.Seebelowforsomethingsto
consider during your installation. ThisOn/Offswitchrequiresaneutral(whitewire)towork.Ifyouhaveno-neutral,pleasepurchaseourdimmerswitch. Anaux(add-on)switchisadevicethatisnotsmart,butallowsyour3-Way(multi-switch)setupto"match"inthattheswitches willrestinaneutralstatewhenpressed.Thetwobrandswe'vetestedare:HomeSeerandGE,whichworkfine. Foradditionalwiringschematicsandinstructions,pleaseseeourwebsite.

Single-PoleInstallation(OneSwitchControlstheLight)
ROMEX (BOX TO LIGHT)
NOTE:Groundwirenotshowntosave illustrative space.

Load

Neutral

Line

IncludedNeutralJumperWire

ROMEX (TO BOX)

120VPowerSource (To the Switch)

WIRINGKEY&PROTIPS
(PleaseseeadditionalPRO-TIPSonPage5ifnecessary)

Load Line/Hot Neutral

Traveler
Shownin3-WayBelow
RomexCable

Remembertoturnoffthepowerpriortoinstallationand ensureallconnectionsaremadepriortoturningthepower backon.Noneedtobeahero!
TheLinewireisHot.Pleaseuseamultimetertolocateit.
Wedidn'tshowthegroundwireintheschematictosave illustrativespace.Pleaseremembertogroundyourswitch (copperorgreenwire).

3-WayInstallation(TwoSwitchesControltheLight)
InovelliSmartSwitch+AuxiliarySwitch*
120VPowerSource (To the Switch)

ROMEX (BOX TO LIGHT)
NOTE:Groundwirenotshowntosave illustrative space.

NOTE:Therearemanydifferent3 &4-Waysetupsincludingusingan auxswitch,smartswitchordumb switch.Pleasecheckoursitefor moreoptions. inovelli.com/lzw30-sn/wiring

Neutral Traveler

Load

Line

IncludedNeutralJumperWire
*We'vetestedHomeSeerandGE'sauxswitchestoworkwithours.
www.inovelli.com/lzw30-sn/setup

ROMEX (TRAVELER BOX TO BOX)
contact@inovelli.com

Traveler Terminal
Neutral Terminal
Aux Switch
page 5

LZW30-SN|On/OffSwitchRedS i

WiringInstructions:NeutralInstallation(QuickNotes)
Pleaseusethispageifyou'dliketoinstallyoursmartswitchwithanexisting,"dumb"switch.Seebelowforsomethingsto
consider during your installation. PleaseusetheWiringKey&ProTipsfrom Page5ifyouhavequestionsaroundthevariouswirecolors. ThisOn/Offswitchrequiresaneutral(whitewire)towork.Ifyouhaveno-neutral,pleasepurchaseourdimmerswitch. Foradditionalwiringschematicsandinstructions,pleaseseeourwebsite.

3-WayInstallation(TwoSwitchesControltheLight)
InovelliSmartSwitch+ExistingDumbSwitch
120VPowerSource (To the Switch)

ROMEX (BOX TO LIGHT)
NOTE:Groundwirenotshowntosave illustrative space.

NOTE:Therearemanydifferent3 &4-Waysetupsincludingusingan auxswitch,smartswitchordumb switch.Pleasecheckoursitefor moreoptions. inovelli.com/lzw30-sn/wiring

Common

Load

On/Off Dumb Switch (NoDimmers)

Neutral Traveler

Line

Load

IncludedNeutralJumperWire

ROMEX (TRAVELER BOX TO BOX)

3-WayInstallation(TwoSwitchesControltheLight)
InovelliSmartSwitch+ExistingDumbSwitch
ROMEX (BOX TO LIGHT)
NOTE:Groundwirenotshowntosave illustrative space.
120VPowerSource (To the Switch)

Cap Load's together
(Loadfrom Traveler+ Load to Light)

NOTE:Therearemanydifferent3 &4-Waysetupsincludingusingan auxswitch,smartswitchordumb switch.Pleasecheckoursitefor moreoptions. inovelli.com/lzw30-sn/wiring
On/Off Dumb Switch (NoDimmers)

Common

Neutral Traveler

Line

IncludedNeutralJumperWire

ROMEX (TRAVELER BOX TO BOX)

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 6

LZW30-SN|On/OffSwitchRedS i
GettingtoKnowYourLZW30-SNSwitch. Nowthatyou'vewiredupyourswitch,it'stimetounderstandthebasicsofyournewsmartswitch.Formoreadvanced configurations,pleaseseePages9-10.

*PleasemakesureyourHUB supportsthesefeatures.See websiteformoredetails.
Including(Pairing)YourSwitch:GeneralInstructions Belowarethegeneralinstructionsonhowtoinclude(pair)theswitch.ForHUBspecificinstructions,pleasescanoneoftheQR CodesonPage1orvisittheURLunderneatheachQRCodeformoreinformation.However,ifyouknowhowtoputyourHUBor Gatewayininclusionmode,youcanfollowtheinstructionsbelowtogetstarted.
IMPORTANT:Ifyouarehavingissuespairing/includingyourdevice,pleaseensureyourswitchiswithinrangeofyourHUB(pages 2-3)orbycheckingtheZ-WavesignalbyholdingdowntheConfigButton(A)forfive(5)seconds(moreinfobelowinthe,"Z-Wave RangeCheck"section).Ifyou'rewithinrangeandtheLEDBar(B)isGREENwhenyouchecktherange,thenyouwillhavetorun anExclusion.PutyourHUBinExclusionmodeandpresstheConfigButton(A)3xuntilyourHUBsaysthedeviceisexcluded.You maythenadd(include)theswitchpertheinstructionsbelow.
Steps1:GatherYourMaterials,FindanAppropriateLocation,andInstallYourSwitch MaterialsNeeded:GangboxwithNeutral,Line&LoadWires,CellPhone/Tablet/Computer,andaZ-WaveenabledHUB/Gateway.
Locateanareatoinstallyourswitchwithintherecommendeddistance(Pages2-3)from yourHUB/Gateway. Walls,furniture,andotherobstructionsmaydegradethecommunicationbetweentheSwitchandyourHUB/Gateway,soplease keepthisinmindwhenselectingalocation. Followtherecommendedwiringinstructionsonpage5--REMEMBER:TURNOFFELECTRICITYBEFOREINSTALLATION!
Step2:Adding(Including)totheNetwork&FinishingtheSetupProcess Nowthattheswitchisphysicallyinstalled,let'sstarttheinclusion(pairing)process.
Turnthepowerbackon andstarttheinclusionprocessonyourHUB/Gateway. Oncetheinclusionprocesshasstarted,presstheconfigbutton(A)3xandtheLEDBar(B)willflashblue.Iftheswitchwas includedsuccessfully,thebarwillturnGREEN,howeveriftheswitchwasnotincludedsuccessfullyitwillturnRED. Z-WaveRangeCheck:EasilycheckwhetherornotyourswitchiswithinrangebyholdingtheConfigButton(A)for5-10 seconds.TheLEDbarwillindicate:RED=NotinRange,orGREEN=WithinRange(GoodSignal).

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 7

LZW30-SN|On/OffSwitchRedS i

Including(Pairing)YourSwitch:SmartThingsInstructions Belowarethegeneralinstructionsonhowtoinclude(pair)theswitchforSamsungSmartThingsusers.

PLEASEREAD:Asofthedatethismanualwaswritten(May27th,2019),theswitchhasnotbeenWWST(WorksWith SmartThingsCertified).However,bythelaunchdateofourproduct,wedoanticipateitwillbeWWSTCertified.Thereasonwe're statingthisisbecauseifyoureceivethisproductpriortothecertification,youwillneedtousetheSmartThingsClassicAppand alsoinstallaDeviceHandlerforyoutoexperienceallthebellsandwhistles.IfyouusetheSamsungConnectAppordonotinstall aDeviceHandlerwiththeSmartThingsClassicApp,theremotefunctionalitywillonlybeon/offanddim.You'llstillbeableto configuretheswitchasshownonPages9-10,buttherewillbenoscenecontrol,notificationsorpowermonitoring.
IMPORTANT:Ifyouarehavingissuespairing/includingyourdevice,pleaseensureyourswitchiswithinrangeofyourHUB(pages 2-3)orbycheckingtheZ-WavesignalbyholdingdowntheConfigButton(A)forfive(5)seconds(moreinfobelowinthe,"Z-Wave RangeCheck"section).Ifyou'rewithinrangeandtheLEDBar(B)isGREENwhenyouchecktherange,thenyouwillhavetorun anExclusion.ForExclusionmode,click,"Menu",then"HubisOnline",then,"Z-WaveUtilities",andfinally,"GeneralDevice Exclusion".ThenpresstheConfigButton(A)3xuntilyourHUBsaysthedeviceisexcluded.Youmaythenadd(include)theswitch.
Steps1:GatherYourMaterials,FindanAppropriateLocation,andInstallYourSwitch MaterialsNeeded:GangboxwithNeutral,Line&LoadWires,CellPhone/Tablet/Computer,andaZ-WaveenabledHUB/Gateway.
Locateanareatoinstallyourswitchwithintherecommendeddistance(Pages2-3)from yourHUB/Gateway. Walls,furniture,andotherobstructionsmaydegradethecommunicationbetweentheSwitchandyourHUB/Gateway,soplease keepthisinmindwhenselectingalocation. Followtherecommendedwiringinstructionsonpage5--REMEMBER:TURNOFFELECTRICITYBEFOREINSTALLATION!
Step2:Adding(Including)totheNetwork&FinishingtheSetupProcess(UsingtheSmartThingsClassicApp) Nowthattheswitchisphysicallyinstalled,let'sstarttheinclusion(pairing)process.Pleasemakesureyouareusingthe, "SmartThingsClassic"app.Ifyou'dliketousetheSamsungConnectApp,pleasechecktheWWSTURLtoseeifInovelliislisted: https://www.smartthings.com/products.Ifit'snot,youwillhavetousetheClassicappwithaDeviceHandler.
Restorepower toyourswitchandifwiredproperly,theLEDbarwilllightup(shouldflashaseriesofcolors,thenturnblue) OpenupyourSmartThingsClassicappandclickonthe,"MyHome"tabfollowedbythe,"Things"tab Scrolltothebottom andclickon,"AddaThing"orclickonthe(+)atthetoprightofthescreen Presstheconfigbutton(A)3xandtheLEDbarshouldflashblue(ifitdoesn't,trypressingthebuttonsfasterorslower) indicatingtheswitchisininclusionmode.Ifsuccessful,theswitchLEDBar(B)willturnGreen.Ifunsuccessful,theLEDBarwill turn RED. Youshouldnowseethatyourdeviceisdetected(itshouldsay,"Z-WaveSwitch"orsomethingsimilar) Afteryourdeviceisdetected,press,"Save"(orifyou'dliketorenameyourdevice,pleasedosoandclick,"Save") Onceyouclick,"Save"apop-upwillappearaskingyouto,"Confirm PairedDevices"--Click,"OK" Now,youshouldbebackatthe,"MyHome"screenandyoushouldbeabletoseeyourswitch! Z-WaveRangeCheck:EasilycheckwhetherornotyourswitchiswithinrangebyholdingtheConfigButton(A)for5-10 seconds.TheLEDbarwillindicate:RED=NotinRange,orGREEN=WithinRange(GoodSignal).
DeviceHandlerInstallation(Abbreviated): Belowisashortenedwaytoinstallthedevicehandler.Formoreindepthinstructions,pleasevisittheURLinthefooter.
LogintoyourIDEAccount(https://graph.api.smartthings.com/)--it'sthesamelogin/passwordasyourmobileapp Clickon,"MyLocations"andthenselectyourlocation Next,clickon,"MyDeviceHandlers"andpressthe,"CreateNewDeviceHandler"button Now,openanewtabinyourbrowserandgoto:github.com/InovelliUSA/SmartThingsInovelli/tree/master/devicetypes/inovelliusa andfindthedevicehandlerfor,"LZW30-SN"andonceyouseetheoptionfor,"Raw",clickonthatbuttonandcopythecode* Next,gobacktoIDEandclickonthe,"From Code"tabandpastethecodefrom GitHub Next,click,"Create",then,"Publish"andfinally,"ForMe"tofinishtheinstallation Finally,toactivatethehandleronyourswitch,goto,"MyDevices"inIDEandfindyourInovelliswitch Clickontheswitch,scrolltothebottom andclick,"Edit"--thenfind,"Type"andthenselectthenewdevicehandlerfrom the dropdownandthenclick,"Update" Now,whenyouopenuptheswitchmenuintheapp,youshouldseetheInovellilogoandatonofcoolconfigoptions

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 8

LZW30-SN|On/OffSwitchRedS i
Switch Configuration Settings Thereareacoupleofwaystoconfigureyourswitch.Thefirstisviatheswitchitself,whilethesecondisviayourHUBor Gateway.Onthispage,we'llshowyouwhichparameterscanbechangedviatheswitchandhowtochangethem whileonPage 10,we'lldefinealloftheparametersandlisttheZ-Wavecommandclassesforreference.Let'sbegin!

Figure1.2-Parametersthatcanbechangedfrom theswitch
NOTE:Belowisthelogicbehindhowtoconfiguretheaboveparameters(Figure1.2)from theswitchitself.Duetospace constraintsofthismanual,we'llshowyouhowtoconfiguresomeofthemorepopularparameters.Formoredetails,pleasevisit ourwebsitewhichwillhavewrittenandvideotutorialsforeachparameterlistedinFigure1.2.
Configuration Logic PLEASENOTE:Duetospaceconstraintsonthe500SeriesChip,therewillbeaslightlearningcurveaswecouldn'toptimize theUserExperiencethewaywewanted.PleaselooktoourwebsitefortutorialvideosandupdatesonimprovedUX. Onceyoumasterthelogicbehindhowtheconfigurationworks,anyoftheparametersinFigure1.2canbechanged.
Toenterconfigurationmode,holddowntheconfigbutton(A)for10-15secondsandtheLEDBar(B)willlightupYELLOW From here,refertoFigure1.2toseewhatparameteryou'dliketochangeandtaptheconfigbuttonthatmanytimes(lookatthe, "About"columntofindtheparameteryou'dliketochangeandthengoonecolumntotheleft--highlightedinred--toseehow manytimesyouneedtopresstheConfigButton(A).Forexample:Ifyouwanttochangethe,"PowerOnState",presstheconfig button(A)1xorifyouwanttochangethe,"LEDIndicatorIntensity",presstheConfigButton(A)4xandsoon). Onceyourparameterhasbeenselected,theLEDBar(B)willblinkYELLOW indicatingwhatparameteryou'reon(1x=1,2x=2, etc)--nowpressupordownonthepaddle(C)toadjusttheparametersettings(Figure1.3-highlightedinred)toyourliking. Finally,onceyou'vesettledonacustomizationyoulike,it'stimetosaveyourconfigurationsettings.Todothis,holdtheconfig button(A)againfor10-15secondsandtheLEDBar(B)willthenblinkCYANtoconfirm.
SpecificExample Usingthelogicabove,let'schangethe,"PowerOnState"toOff(whenpowerisrestoredafterapower outage,theswitchwillreturntotheOffstateregardlessofifitwasonprior).
HoldtheConfigButton(A)for10-15secondstoenterconfigmode(LEDBarwilllightupYELLOW) LookingatFigure1.2,you'llnoticethattoedit,"PowerOnState",youneedtotaptheconfigbutton1x AftertappingtheConfigButton(A)1x,theLEDBar(B)willblinkYellowone(1)timefollowedbyafive(5) secondpause,thenblinkagainone(1)time,followedbyafive(5)secondpause,etc--thisindicatesthe parameterbeingeditedisParameter1(Parameter2wouldbe2xfollowedby5secondpause,etc) Figure1.3(Page10)showsthatthePowerOnStatehastheoptionsof0,1,or2(0=LastState,1=On,2 =Off).Sincewewanttochangethedefaultto,"Off",we'llpressuponthePaddle(C)three(3)times. Now,we'llsavethisconfigurationbyholdingdownontheConfigButton(A)for10-15seconds(LEDBar (B)willblinkCYANtoconfirm andsave).
NOTE:Toeasilyunderstandwhatparameteryou'reediting,theLEDBarwillslowblink(ie:ifyourelease yourfingerfrom thepaddleandyou'reonparameter6,theswitchwillblink6xtoshowyou).
Slowblinks=multiplesof10/Fastblinks=singledigits Example:34=3slowblinksfollowedby4fastblinks

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 9

LZW30-SN|On/OffSwitchRedS i
SwitchParameters Belowyou'llfindthevariousparametersassociatedwithyourswitch.Thereareatonofoptionsforcustomizationandasyoucan imagine,it'shardtowriteoutallthepossibilitiesinamanual.Pleaseusethisasaguide,butalsofeelfreetocheckoutoursite wherewe'llgivesomespecificexamplesusingeachparameter.

SwitchCheatCodes Belowisachartthatwillhelpyouunderstandwhatyourswitchisdoingsoyoudon'tgetlostinaseaofRGBcolorsandLEDstrobes.

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 10

LZW30-SN|On/OffSwitchRedS i

Z-WaveCommandClasses
5E-COMMAND_CLASS_ZWAVEPLUS_INFO 26-COMMAND_CLASS_SWITCH_BINARY 70-COMMAND_CLASS_CONFIGURATION 85-COMMAND_CLASS_ASSOCIATION 59-COMMAND_CLASS_ASSOCIATION_GRP_INFO 55-COMMAND_CLASS_TRANSPORT_SERVICE 86-COMMAND_CLASS_VERSION 72-COMMAND_CLASS_MANUFACTURER_SPECIFIC 5A-COMMAND_CLASS_DEVICE_RESET_LOCALLY 73-COMMAND_CLASS_POWERLEVEL 98-COMMAND_CLASS_SECURITY 9F-COMMAND_CLASS_SECURITY_2 5B-COMMAND_CLASS_CENTRAL_SCENE 6C-COMMAND_CLASS_SUPERVISION 32-COMMAND_CLASS_METER 75-COMMAND_CLASS_PROTECTION 22-COMMAND_CLASS_APPLICATION_STATUS 7A-COMMAND_CLASS_FIRMWARE_UPDATE_MD

Z-WaveAssociationGroups

ResettingYourDevice
YoumayholdtheConfigButton(A) for 20 seconds or use a certified controllertoremovethedevice from yournetworktofactory default.Onlyusethisprocedurein theeventthatthenetworkprimary controllerismissingorotherwise inoperable.

Group1:Lifeline--Membersofthisgroupwillreceiveunsolicitedmessagesrelatedtothestatusoftheswitch. Group2:BasicSet--Description:1.SinglepressUPbuttonsendsBasicSet(0xFF)and2.SinglepressDownsendsBasicSet(0x00)

FederalCommunicationsCommission(FCC)Statement
FCCCaution:Anychangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatethis equipment.ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmful interference,and(2)thisdevicemustacceptanyinterferencereceivedincludinginterferencethatmaycauseundesiredoperation.
NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsare designedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.
Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmful interferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause harmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowingmeasures:Reorientorrelocatethereceivingantenna,increasetheseparationbetweentheequipmentandreceiver, connecttheequipmentintoanoutletonacircuitdifferentfrom thattowhichthereceiverisconnectedorconsultthedealeroranexperiencedradio/TVtechnician forhelp.Thisequipmentshouldbeinstalledandoperatedwithminimum distance8in(20cm)betweentheradiatorandyourbody.
ICCaution:ThisdevicecomplieswithIndustryCanadalicence-exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:(1)thisdevicemay notcauseinterference,and(2)thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.
DECLARATIONDECONFORMITED'INDUSTRIECANADA:CepériphériqueaététestéetreconnuconformeauxlimitesspécifiéesdansRSS-210.Sonutilisation estsoumiseauxdeuxconditionssuivantes:(1)ilnedoitpasprovoquerd'interférencesgênanteset(2)ildoittolérerlesinterférencesre.ues,notamment cellessusceptiblesd'enperturberlefonctionnement.

WarrantyandSpecifications
Warranty:Inovelliwillreplaceanydefectiveunitforthelifetimeoftheunit,pendingtheunitwasusedinthemanneritwasintendedto.Pleaseemailusat: contact@inovelli.com orvisitusatwww.inovelli.com/warrantyforfulldetails.
SpecificationsforModel#LZW30-SN: Power:120VAC,60Hz,Signal(Frequency):908.42MHz,OperatingTemperatureRange:32-104°F(0-40°C) Maximum Load:600W Incandescentor300W LEDor150W CFL Range:Upto100meterslineofsightbetweentheWirelessController(HUB)andtheclosestZ-WaveModule Forindooruse.Specificationssubjecttochangewithoutnoticeduetocontinuingproductimprovement. Approval:ULListed/FCC/IC/Z-WavePlusCertified CANICES-3(B)/NMB-3(B)

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 11

LZW30-SN|On/OffSwitchRedS i

ProjectLightsOut
Youmayhavenoticedoursignaturesandprojectnameontheinsideoftheboxandwondered,"whatisthatallabout?".Well, greatquestion!Allofourproductshaveaprojectnameassociatedwiththem thatmeanssomethingtousandspeaksdirectlyto thedeviceitself.It'spersonalityifyouwill.Inadditiontotheprojectname,oursignaturesindicatethatwe'veallsignedoffonthe project.Webelieveintheprojectandworkedhard,alongwithyou,tobringittolife.

Project,"LightsOut"startedasarallycrythatweweregoingtoturnthelightsoutonothersmarthomeswitcheswiththis productbecauseitwouldbethatgood.Ifyouhaven'tfollowedusforthepastyearorsoandthisisyourfirstinteractionwiththe brand,ourapproachtobuildingproductsisthatwewantsomethingwe'dputinourownhome(we'reallsmarthomeowners)and wewanttobuildourproductswithyoutakingtheridewithus.Thatis,thesearecommunitybuiltproductsinwhich100's,ifnot 1000'sofpeopleoutsideofInovellihavecontributedto.Thisswitchisourfirstopportunitytobuildfrom scratchatruecommunity assembledproductfrom bothahardwareandfirmwareside(asourolderswitcheswerewhite-labeledandwedidnothaveany influenceinthedesignandonlythefirmwarewascustomizeable).
So,thankyoufornotonlyyoursupportbutforhelpingusputoutthenextgenerationofsmartswitches.Here'stoturningthe "lightsout"onordinarysmartswitches!

Eric H. Founder/CEO
EricM. CTO

Irememberkickingthisprojectoffwithourmanufacturerandthinking,"thisisgoingtobeinsane andlikelyimpossibletopulloff,butherewego,let'sseewhathappens."Wewantedsomething thatcouldbeinstalledinany3-Wayscenario(withtheoptionofusinganauxswitch,dumbswitch oranothersmartswitch),firmwarecustomizationthatcouldbeusedbyanyHUBregardlessofif theHUBsupportedparameters,andallthebellsandwhistlesZ-Wavehastooffer.Butherewe are...wedidit...andI'm incrediblyproudofeveryone!
Ithinkmyfavoritepartaboutthisisthatnoweveryonegetstoexperiencecustomization.The problem wehadwithourGen1switcheswasthattheywereonlyassmartastheHUBtheywere pairedto.Inotherwords,iftheHUBwaslimitedinwhatitcoulddo,sowereourswitches.Withour newswitches,everyonecancustomizetheirsettingsfrom theswitchitself(powerondefault,LED Intensity,LEDbarcolor,etc).Thisisagamechangerandkudostoourfirmwareteam forfiguring this out.

Micah CFO
Nathan CSO
Kyle Directorof Cust.Service

Ilovethefactthatproject"LightsOut"wastrulythecollaborativeeffortoffolksinthesmarthome community,ourmanufacturerandtheInovelliteam.Wewereabletocombinegreatideasand expertisefrom allthreeofthesechannelstocreatesomethingfrom scratchthatwe're super-excitedabout­andIhopeothersareaswell.Wearenotthesmartestpeopleoutthereand weknowthat!Butifwecanbehumble,listenandlearnfrom thefeedbackofourcustomersand thebroadersmarthomecommunity,webelievewecanofferproductsthataretrulyspecial.
MyfirstcalltoalargeB2Bclientwassomuchfuntalkingaboutthisswitch.Theysaid,"thissolves fortwoofourbiggestproblems.Therearesomanytimeswherepeopleforgetthey'vearmedtheir securitypanelandthefactthatyourswitchcanlightupwhenthesystem isarmedisamazing.The abilitytodisabletherelaysothattheswitcheswillworkwithoursmartbulbsreallyhelpswithour largestproblem...peopleswitchingthepoweroff,renderingourbulbsuseless."Ilovethisswitch andit'sgreattoknowwe'remakinganimpactoutthereandreallyhelpingnotonlyourfans,but complimentingbrandsthatwelookupto.
Thebestpartaboutthisswitch...itspeakstoourteam'sinternalpassionformakingproducts betterandbetterandconstantlytryingtobethebest.I'vebeenwiththecompanyforsometime nowandruntheCustomerSupportteam.Wehaveahugestickypadthat'sinEric'sofficethatwe writedownwayswecanimproveourproductsbasedoncustomerpain-points.Oneofthebiggest issuesisthatpeoplearen'tfamiliarwithZ-Waveandtherange,soIwrotedowntheideaofhaving aZ-Waverangenotifierbuiltintotheswitchandtheteam madeithappen.Nowpeoplewillbeable toinstantlycheckiftheirswitchiswithinrange.It'sawesometobeabletosolvefortheseissues andletpeopleknowthatwenotonlylisten,buttryourbesttoimprovebasedontheirfeedback.

www.inovelli.com/lzw30-sn/setup

contact@inovelli.com

page 12



References

PDF Presentation Adobe Photoshop CC www.ilovepdf.com