PDF Download.aspx?pos=download&fct=getasset&id1=BTLV 45543
s New Revised Type P1 Kits and Accessories
Main and Sub-Feed Breaker Mounting Kits with Breakers

Max IR (kA) at a

Frame Size
Reference

Revised P1 Catalog No.

Description

MBKQR1125A Kit w/2-pole QR2 125A breaker 10 -- -- --

QR 1-ph 225A Max.

MBKQR1150A Kit w/2-pole QR2 150A breaker 10 -- -- -- MBKQR1175A Kit w/2-pole QR2 175A breaker 10 -- -- -- MBKQR1200A Kit w/2-pole QR2 200A breaker 10 -- -- --

MBKQR1225A Kit w/2-pole QR2 225A breaker 10 -- -- --

MBKQR1125H A Kit w/2-pole HQR2 125A breaker 65 -- -- --

HQR 1-ph 225A Max.

MBKQR1150H A Kit w/2-pole HQR2 150A breaker 65 -- -- -- MBKQR1175H A Kit w/2-pole HQR2 175A breaker 65 -- -- -- MBKQR1200H A Kit w/2-pole HQR2 200A breaker 65 -- -- --

MBKQR1225H A Kit w/2-pole HQR2 225A breaker 65 -- -- --

MBKQR3125A Kit w/3-pole QR2 125A breaker -- 10 -- --

QR2 3-ph 225A Max.

MBKQR3150A MBKQR3175A MBKQR3200A

Kit w/3-pole QR2 150A breaker Kit w/3-pole QR2 175A breaker Kit w/3-pole QR2 200A breaker

-- 10 -- -- -- 10 -- -- -- 10 -- --

MBKQR3225A Kit w/3-pole QR2 225A breaker -- 10 -- --

MBKQR3125H A Kit w/3-pole HQR2 125A breaker -- 65 -- --

HQR2 3-ph 225A Max.

MBKQR3150H A Kit w/3-pole HQR2 150A breaker -- 65 -- -- MBKQR3175H A Kit w/3-pole HQR2 175A breaker -- 65 -- -- MBKQR3200H A Kit w/3-pole HQR2 200A breaker -- 65 -- --

MBKQR3225H A Kit w/3-pole HQR2 225A breaker -- 65 -- --

MBKVAM3150A RP1 150A MB kit, 35kA 3ph 3VA52 -- 85 35 18

MBKVAM3200A RP1 200A MB kit, 35kA 3ph 3VA52 -- 85 35 18 3VA52 3-ph MBKVAM3225A RP1 225A MB kit, 35kA 3ph 3VA52 -- 85 35 18
250A MBKVAM3250A RP1 250A MB kit, 35kA 3ph 3VA52 -- 85 35 18 Max.
MBKVAH3200A RP1 200A MB kit, 65kA 3ph 3VA52 -- 100 65 25

MBKVAH3250A RP1 250A MB kit, 65kA 3ph 3VA52 -- 100 65 25

MBKVAM1300A RP1 300A MB kit, 35kA 1ph 3VA53 85 -- -- --

MBKVAM1400A RP1 400A MB kit, 35kA 1ph 3VA53 85 -- -- -- 3VA53 3-ph MBKVAM3300A RP1 300A MB kit, 35kA 3ph 3VA53 -- 85 35 18
400A MBKVAM3400A RP1 400A MB kit, 35kA 3ph 3VA53 -- 85 35 18 Max.
MBKVAH3300A RP1 300A MB kit, 65kA 3ph 3VA53 -- 100 65 25

MBKVAH3400A RP1 400A MB kit, 65kA 3ph 3VA53 -- 100 65 25

a DC System Voltages are not available for RP1 series.

For more information about what your Siemens Unassembled Panelboard Distributor can do for you, contact your local distributor.
Note: 1) Original P1 kits will not fit Revised P1 Panels. 2) Revised P1 kits will not fit original P1 Panels. 3) Factory installed and Field installable Service Entrance Barrier kits are now
available as required by UL67. (In COMPAS, you must select Service Entrance Required.)

120/240V 208/120V 480Y/277V 600Y/347V 120/240V 240V 480Y/277V 480V 600Y/347V 600V

d Type P1 Panelboards Ground Bars, Filler Plates and Accessories

Catalog No.

Description

BK1A

Bonding kit for 250A max. Revised P1 Panels

EGK ECGK IGK

Al Ground Bus 44 Connections Cu Ground Bus 44 Connections Insulated Al Ground Bus

ICGK DFFP1A DFFP01B

Insulated Cu Ground Bus 1" Branch circuit blank filler plate - BL/BQD/xGB/3VA41 provisions a P1 Main, Blank Filler (Small main opening and all sub-feed)

DFFPVA41A MBKQRFK

RP1 Main/Sub-feed 125A max. - 3VA4/BL/BQD/ED/xGB filler (replaces DFFPED01 ref. 12-A-1802-01)
P1/Revised P1 Filler for 1PH/3PH QR. Horizontal Mount only.

DFFPFD01 DFFPJD01 MBKVA5363JD

P1 Main, FD Filler, 250A Frame P1 Main, JD Filler, 400A Frame (Small opening) prior to 3VA RP1 Deadfront Filler w/small MB opening for 400A Max. 3VA53/63

DFFP01C

RP1 400A Main Blank Filler Plate - 1 Piece for large opening

DFFPJD02

RP1 400A w/JD Main - 1 Piece for large opening

DFFPVA5363A RP1 400A w/3VA53/63 Main - 1 Piece for large opening

LNLK5X12A LNLK7X18A LNLK4X11B

RP1 1/0 Neutral Lug Kit [(5x)1/0 + (12x) #6] (17 pos) d RP1 1/0 Neutral Lug Kit [(7x)1/0 + (18x) #6] (25 pos) d RP1 & P3 2/0 Neutral Lug Kit (15 pos) d

LNLK6X17B LNLK7X20B CNLK42B

RP1 & P3 2/0 Neutral Lug Kit (23 pos) d RP1 & P3 2/0 Neutral Lug Kit (27 pos) d RP1 CU Neutral Lug Kit, 42B - 2 short & 2 long strips (17 & 25 pos) d

CNLK54B 2NLK42B 2NLK54B 42NLK54B SEBKRP1V1 SEBKRP1V2 SEBKRP1V3 SEBKRP1V4 SEBKRP1V5 SEBKRP1V6

RP1 CU Neutral Lug Kit, 54B - 4 long strips (25 pos) d RP1 250A 200% Neutral Lug Kits d RP1 250A 200% Neutral Lug Kits d RP1 400A 200% Neutral Lug Kit d FD, QJ, QR Service Entrance Barrier Kit (Revised P1) f ED Service Entrance Barrier Kit (Revised P1) f BL/BQD Service Entrance Barrier Kit (Revised P1 - back-fed) f xGB Service Entrance Barrier Kit (Revised P1) - back-fed f BL/BQD/xGB RP1 Service Entrance Barrier Kit -old w/steel MB bracket f BL/BQD/GB/3VA4 RP1 Service Entrance Barrier Kit - use w/new MB kit f

SEBKRP1V7

3VA52/61/62 Horiz. Mount, RP1 Service Entrance Barrier Kit f

SEBKRP1P2P3V1 JD, LD, 3VA53/63 Service Entrance Barrier Kit (RP1, P2, P3) f

MCHK

Metal Card Holder Kit

EWK1

End Wall Kit with KO's (20"W x 5.75"D)

IMK1

Interior Adjusting Kit

LPDC01 LPDC02 NBK01A

Directory Card (Pack of 10; ref. 12-1110-01) Directory Card Holder (Pack of 10; ref. 11-1824-01) STICK-ON NUMBERS 1 THRU 60 (includes BT - 1/2" size)

NBK02A NBK03A P1SCRWS P1CONBPHCU

STICK-ON NUMBERS 61 THRU 120 (includes BT - 1/2" size) STICK-ON NUMBERS 121 THRU 240 (includes BT - 1/2" size) Branch Breaker Mounting Screws for P1 s Connector kit - 6 pcs. B phase Copper

P1CONBPHAL P1CONACPHCU LPJSPDNUT01

Connector kit - 6 pcs. B phase Aluminum Connector kit - 6 pcs. A or C phase Copper g J-type Speed Nut Lighting Panel Fronts, 25 pcs. per pack

LPKEY01A

B363A Key for FAS-Latch Lock, 4pcs. per pack

LPLOCK01A P1DFS250AFT P1DFS250ANFT

FAS-Latch Lock with 2 Keys (B363A) RP1 250A DF Support FT 4/kit w/hardware RP1 250A DF Support NFT 4/kit w/hardware

P1DFS400A

RP1 400A DF Support 4/kit w/hardware

a Filler plates and ground bars are not included with panelboards and need to be ordered separately. Qty 1 #DFFP1A filler plate must be ordered for every circuit position not occupied by a breaker pole. (i.e. 42 ckt panel with 32 breaker poles need 10 DFFP1As).
s Screws are included with interior. Qty 1 equals 42 screws. d For use with Revised P1 only. Will not work with original P1. f Factory installed and Field installable Service Entrance Barrier kits are now available as
required by UL67. (In COMPAS, you must select Service Entrance Required). g Use for both CU and AL Bus Interiors.

s Lug Kits - Main or Feed Thru (for Revised P1 only)

Ampere Rating

Wire Material Range

Service

AI

(1) #6 AWG-350 kcmil Cu or Al

1 Phase 3 Phase

250

Cu

(1) #6 AWG-350 kcmil Cu

1 Phase 3 Phase

AI

(2) 1/0-250 or (1) #2 AWG-600kcmil

1 Phase 3 Phase

400

Cu

(1) 1/0-600 kcmil (CU cable only)

1 Phase 3 Phase

400

Al

(1) AL 1/0-750kcmil (2) AL/CU 250kcmil max. (max. 600 kcmil Cu wire)

1 Phase 3 Phase

Catalog No.
MLKA1A MLKA3A
MLKC1A MLKC3A
4MLKA1A 4MLKA3A
4MLKC1A 4MLKC3A
4MLKA1B 4MLKA3B

f

All

P1 Branch Circuit Breakers

2-Pole and 3-Pole Max IR (kA) at

Amp Breaker Breaker Rating Family Type

BL

10 10 -- -- -- --

BL

BLH

22 22 -- -- -- --

100

BT

twin

1-pole

HBL BT BTH

65 65 -- -- -- -- 10 -- -- -- -- -- 22 -- -- -- -- --

BQD

BQD

65 65 14 -- 10 --

NGB 100 100 25 -- 14 --

xGB a

HGB 100 100 35 -- 14 --

LGB 100 100 65 -- 14 -- 125
SEAB 65 65 25 25 14 --

3VA41a MEAB 85 85 35 35 18 --

HEAB 100 100 65 65 25 --

a xGB and 3VA41 can only be used in P18... series UPB panels

Amp Ratings Available
15-100 15-100 15-100 15 or 20
15 or 20
15-100 15-125 15-125 15-125 15-125 15-125 15-125

Published by Siemens 2021
Siemens Industry, Inc. 3617 Parkway Ln Peachtree Corners, GA 30092
Siemens Technical Support: 1-800-333-7421 info.us@siemens.com
Order No. PBPM-UAPBB-0521 Printed in USA All Rights Reserved © 2021, Siemens Industry, Inc.
The technical data presented in this document is based on an actual case or on as-designed parameters, and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects. Actual results are dependent on variable conditions. Accordingly, Siemens does not make representations, warranties, or assurances as to the accuracy, currency or completeness of the content contained herein. If requested, we will provide specific technical data or specifications with respect to any customer's particular applications. Our company is constantly involved in engineering and development. For that reason, we reserve the right to modify, at any time, the technology and product specifications contained herein.

UNASSEMBLED PANELBOARDS
The Siemens Advantage
Revised P1 with 3VA options usa.siemens.com/powerdistribution

New Revised P1 Unassembled Panelboards
To better serve the needs of our customers, we are proud to announce that we are an Authorized Siemens Unassembled Panelboard Distributor. What this means to you is product flexibility, quicker job turn-around, and affordable pricing. All Siemens unassembled panelboards are fully backed for high-quality, trouble-free operation and are labeled as Suitable for use as Service Entrance Equipment.
Same day availability: Over the counter availability means you're on and off the job without the delays that come with waiting for factory assembled panelboards.
Product consistency: Whether you are starting a new project, replacing parts, or adding on to an existing project, the unassembled panelboard offering is an exact match to the Siemens factory built panelboards (feed-thru versions only). While this ensures that you enjoy the same great features of the P1 panelboard, it also guarantees your job sites will have the same look, quality, and parts whether you ordered them factory-built, utilized our unassembled panelboard inventory, or used a combination of the two. (Note: Non-feed-thru variations are available as factory assembled without subfeed space in a 6" shorter enclosure.)
Flexibility and ease of assembly: Customer oriented design creates installation convenience. For all of its one-of-akind features, the P1 panelboard is also designed to be extremely user-friendly. For instance, field convertible main breaker and main lug kits, (through 400 amps), will allow you to switch from main lug to main breaker, and vice versa with no change in box size or additional cabling. Plus, lay-in construction and/or removable lugs make wiring the main and neutral lugs easier and faster. To further speed wiring, as well as reduce clutter, the P1 panel also features a split neutral design and branch neutral connections are near the breaker connections. Additionally, field addable sub-fed breakers (up to 250 amps) or feed through lug kits can be field installed without utilizing any of your feeder breaker positions or increasing your box height. Furthermore, the unique design allows the panel to be inverted in the field and keep its labeling legible.
New for Revised P1 Panelboards 1) BL/BQD and xGB/3VA41 type breakers are now available in main and subfeed
positions (using the same universal strap kit). 2) 3VA 250A and 400A Main Breakers are available in both TMTU (Thermal
magnetic trip) and ETU (Electronic Trip) variations. 250A are also available for Sub-feed. 3) 2/0 Neutral strips are now standard on all P18... series interiors for xGB/3VA41 breakers. Accessory kits are also available for field replacement. 4) BT twin 15A and 20A breakers are now available that can be placed wherever a 1-pole BL 15A or 20A can be used.

Revised P1 Unassembled Panelboards (introduced 2015) offer a wealth of features and benefits!

1 Completely symmetrical boxes may be

s

mounted with either end up. There are two

(or four) pre-punched equipment ground

connector locations for contractor friendly

installation.

a

2 Box comes pre-punched for optional, field-

installable door-in-door or hinge-to-box style

trims. The panel box will accept both

standard ground connector (EGK and ECGK)

assemblies and insulated ground connector

kits (IGK and ICGK).

3 Interior is completely symmetrical allowing it
to be changed from top to bottom feed by simply rotating the interior.

4 Choose either a Main Breaker kit or Main Lug

kit with which to terminate your incoming

cables. Main lug kits are contractor friendly

with lay in lugs (or removable lugs) through

d

f

350 Kcmil (250 amp panel) or (1) 600 Kcmil or (2) 250 Kcmil connectors for 400 amp

panels. No line connectors in the P1 panel

g

require multiple wires under one screw. Main

Breaker kits (250 amps and below) are

horizontally mounted allowing field

convertible top or bottom feeds to be

performed easily. MLO kits and Main Breaker

Kits are interchangeable and can be changed/

added in the field without making changes to

the enclosure or interior.

5 Branch neutral connections are near the

breaker connections to speed wiring and

reduce clutter. The standard P1 neutral is

h

rated for 100% of the panel's ampacity and

will accept copper or aluminum wire.

Optional 200% neutral kits and 2/0 neutral

kits are also available. (2/0 neutrals are now

standard on all P18... series interiors)

6 The panel includes space to add (1) sub-feed

breaker (max 250 amps), feed-thru lugs or

j

TPS3 or new TPS4 (SPD) kit. The P1 panel

with the TPS3/TPS4 SPD unit installed is

complementary listed to the standard for SPD

units and meets the requirements for an

electronic grade panelboard. (New BSPD

series Bolt-on Surge products can be added

in unit space freeing up this sub-feed space

for feed-thru lugs or sub-feed breaker)

k

7 Siemens standard trim has hidden hinges and

mounting hardware for added safety. The

rounded door corners not only enhance the

panel's appearance but also help to eliminate

injuries caused from sharp corners.

8 Semi-flush lock comes standard. Easily
identified locked position denoted by keyway
being horizontal when door has been locked.

Ordering is as easy as a s d f

a Type P1 Unassembled Panelboards Metal Components: Interiors, Boxes & Fronts

1 Phase, 3 Wire uses BL, BLH, HBL or BQD style breakers

Bus Ampere Rating

Max. No. of Poles

Revised P1 Interior

Box a

Front s

18

P1A18MC250AT WP/B32

S/F32B

30

P1A30MC250AT WP/B38

S/F38B

250

42

P1A42MC250AT WP/B44

S/F44B

54

P1A54MC250AT WP/B50

S/F50B

30

P1A30MC400AT WP/B62

S/F62B

400

42

P1A42MC400AT WP/B68

S/F68B

54

P1A54MC400AT WP/B74

S/F74B

18

P1A18MC250CT WP/B32

S/F32B

30

P1A30MC250CT WP/B38

S/F38B

250

42

P1A42MC250CT WP/B44

S/F44B

54

P1A54MC250CT WP/B50

S/F50B

30

P1A30MC400CT WP/B62

S/F62B

400

42

P1A42MC400CT WP/B68

S/F68B

54

P1A54MC400CT WP/B74

S/F74B

3 Phase, 4 Wire uses BL, BLH, HBL or BQD style breakers

18

P1X18MC250AT WP/B32

S/F32B

30

P1X30MC250AT WP/B38

S/F38B

250

42

P1X42MC250AT WP/B44

S/F44B

54

P1X54MC250AT WP/B50

S/F50B

30

P1X30MC400AT WP/B62

S/F62B

400

42

P1X42MC400AT WP/B68

S/F68B

54

P1X54MC400AT WP/B74

S/F74B

18

P1X18MC250CT WP/B32

S/F32B

30

P1X30MC250CT WP/B38

S/F38B

250

42

P1X42MC250CT WP/B44

S/F44B

54

P1X54MC250CT WP/B50

S/F50B

30

P1X30MC400CT WP/B62

S/F62B

400

42

P1X42MC400CT WP/B68

54

P1X54MC400CT WP/B74

3 Phase, 4 Wire uses BQD style breakers

S/F68B S/F74B

18

P1E18MC250AT WP/B32

S/F32B

30

P1E30MC250AT WP/B38

S/F38B

250

42

P1E42MC250AT WP/B44

S/F44B

54

P1E54MC250AT WP/B50

S/F50B

30

P1E30MC400AT WP/B62

S/F62B

400

42

P1E42MC400AT WP/B68

S/F68B

54

P1E54MC400AT WP/B74

S/F74B

18

P1E18MC250CT WP/B32

S/F32B

30

P1E30MC250CT WP/B38

S/F38B

250

42

P1E42MC250CT WP/B44

S/F44B

54

P1E54MC250CT WP/B50

S/F50B

30

P1E30MC400CT WP/B62

S/F62B

400

42

P1E42MC400CT WP/B68

S/F68B

54

P1E54MC400CT WP/B74

S/F74B

120/240V Bus Material Aluminum
Aluminum
Copper
Copper 120/208V
Aluminum
Aluminum
Copper
Copper 480Y/277V
Aluminum
Aluminum
Copper
Copper

a Type P1 Unassembled Panelboards a Interiors Only­Less Branch Breakers

Interiors for xGB or 3VA41 Breakers -- 3-Phase, 4-Wire

Bus Ampere rating

Max. No. of Poles

Revised P1 Interior

Box a

Front s

18

P1818MC250AT WP/B32

S/F32B

30

P1830MC250AT WP/B38

S/F38B

250

42

P1842MC250AT WP/B44

S/F44B

54

P1854MC250AT WP/B50

S/F50B

30

P1830MC400AT WP/B62

S/F62B

400

42

P1842MC400AT WP/B68

S/F68B

54

P1854MC400AT WP/B74

S/F74B

18

P1818MC250CT WP/B32

S/F32B

30

P1830MC250CT WP/B38

S/F38B

250

42

P1842MC250CT WP/B44

S/F44B

54

P1854MC250CT WP/B50

S/F50B

30

P1830MC400CT WP/B62

S/F62B

400

42

P1842MC400CT WP/B68

S/F68B

54

P1854MC400CT WP/B74

S/F74B

480Y/277V d Bus Material Aluminum
Aluminum
Copper
Copper

a All box dimensions are 20"W X 5.75"D. Height dimensions are equal to the last 2 digits of the box's catalog number. The box catalog number begins with either WP for NEMA 3R/12 or B for NEMA 1 enclosures. (i.e. B32 or WP32). When ordering a N3R box, the front is part of the enclosure and does not need to be ordered separately.
s Catalog number begins with either S for surface or F for flush front (i.e. S32B or F32B).
d All P18... series interiors now accept both xGB series and 3VA41 series branch breakers. Previous P17... series only accepts xGB series breakers.

s Breaker Mounting kits (125A-250A kits can be used as subfeed for both 250A and 400A panels)

Amp Rating Breaker Types

Revised P1 Catalog No. d

125A max

RP1 1 Phase Main/SF kit BL/BQD/GB/3VA4 (BL/BQD 100A max.)
RP1 3 Phase Main/SF kit BL/BQD/GB/3VA4 (BL/BQD 100A max.)

MBKVA41A MBKVA41B

225A RP1 1 Phase Main/SF kit QR - 225A max MBKQR1A max f RP1 3 Phase Main/SF kit QR - 225A max MBKQR3A

250A max

RP1 1 Phase Main/SF kit 3VA52/62 - 250A max
RP1 3 Phase Main/SF kit 3VA52/62 - 250A max

MBKVA5262A MBKVA5262B

RP1 400A 3VA Main Strap kit, 1 Phase or 3 Phase includes: Small and Large Fillers

MBKVA5363A

400A RP1 400A JD to 3VA53/63 Retrofit kit max s 1 Phase/3 Phase
- This kit will allow 3VA53/63 in old 400A RP1 with small Deadfront opening

MBKVA5363JD

Replaces MBKBL1A a MBKBC1NBA a MBKBL3A a MBKBC3NBA a none
none
none
none
none

a Parts will no longer be available after inventory is depleted. OK to use up inventory. s 400 amp kit is for main only -- not allowed for subfeed breaker. d MBKBFA kit is available to mount BL/BQD/xGB/3VA41 2-pole or 3-pole in unit space as a
Back-Fed Main. This occupies branch space and reduces circuit count by 2 or 3 positions. (includes Neutral Lug, "MAIN" label and instructions). f Although QR is rated 250A, it is limited to 225A in panelboard.


Adobe PDF Library 15.0 Adobe InDesign 16.2 (Windows)