Easergy P3
Full PDF Document
If the inline viewer fails, it will open the original document in compatibility mode automatically. You can also open the file directly.
Extracted Text
2018 Catalog Easergy P3 Network Protection Relays PM106568 General Contents Range description 6 Easergy P3 Standard 28 Easergy P3 Advanced 48 Easergy digital experience 78 Additional modules and accessories 88 Schneider Electric service 98 Ordering 102 schneider-electric.com Easergy P3 Catalog | 3 Take the Easergy P3 further with EcoStruxtureTM 450,000 EcoStruxureTM systems deployed since 2007 with the support of our 9,000 system integrators. Efficient asset management Boost your efficiency and reduce downtime using predictive maintenance tools. EcoStruxureTM architecture and interoperable technology platform bring together energy, automation, and software. This provides you with enhanced value through greater safety, reliability, efficiency, sustainability, and connectivity. Turn data into action EcoStruxureTM architecture lets you maximize the value of your data. It helps you:: � Translate data into actionable intelligence and better business decisions � Make informed decisions to secure uptime and operational efficiency thanks to real-time control platforms � Get visibility into your electrical distribution by measuring, collecting, aggregating, and communicating data 24/7 connectivity Make better informed decisions with real-time data that's available everywhere, anytime. Increased safety Enhance your people and equipment's safety with embedded arc flash protection that's based on proven designs and experience. Connect Collect Analyze Take action Connect everything, from shop floor to top floor Capture critical data at every level, from sensor to cloud Convert data into meaningful analytics Drive action through real-time information and business logic CLOSE THE LOOP End-to-End Cybersecurity Cloud and/or On Premise EcoStruxure Platform Building Data Center Industry Apps, analytics, and services Edge control Connected products Infrastructure EcoStruxureTM Building EcoStruxureTM Power EcoStruxureTM IT EcoStruxureTM Machine EcoStruxureTM Plant EcoStruxureTM Grid 4 | Easergy P3 Catalog schneider-electric.com PM106574 PM106572 Easergy P3 at a glance What is Easergy P3? Easergy P3 is a complete range of protection relays for medium voltage applications, including feeder, motor, transformer, and generator protection. It embeds all the latest communication protocols on serial or Ethernet links. Based on more than 100 years of experience in network protection relays, Easergy P3 benefits from the reliability of Sepam, MiCOM and Vamp. Unparalleled Efficiency Better Connectivity Enhanced Safety � Simple selection and ordering with EcoReal MV � Simplified configuration with the new eSetup Easergy Pro setting tool � Faster delivery with on-the-shelf availability of standard configurations � Simpler operation and maintenance with the Easergy SmartApp � 9 communication protocols in one box, including IEC 61850 � Increased number of inputs and outputs for more possibilities � Embedded arc protection � Built-in virtual injection testing � Compliant with international standards (i.e. IEC 60255-1) Range overview P3G30/P3G32 Generator di erential P3U30 Universal P3T32 Transformer di erential P3U30 Universal P3F30/P3L30 Directional & Line di . P3U30 Universal P3M30/P3M32 Motor di erential T GG U T UL L F U U U U UU M UL L GU M M DM105528 schneider-electric.com Easergy P3 Catalog | 5 Easergy P3 Range description 6 | Easergy P3 Catalog schneider-electric.com Easergy P3 Range description Overview 8 Selection guide 9 Selection guide by application 12 Arc flash application 12 Feeder/incomer application 13 Motor application 15 Transformer application 16 Generator application 18 Capacitor application 19 Communication Examples of network architectures 21 schneider-electric.com Easergy P3 Catalog | 7 PM106572 PM106574 Range description Easergy P3 Standard Easergy P3 Advanced Overview Easergy P3 is a family of digital protection relays for distribution networks dedicated to: � Buildings and Industry: �� Retail �� Hotels �� Healthcare �� Education and research �� Transportation �� Industrial buildings �� Data Center � Utilities - Energy distribution � Large sites: �� Oil and Gas �� Mining �� Mineral and Metals �� Water Easergy P3 protection relay is based on proven technology concepts and developed in close cooperation with customers, so it's built to meet your toughest demands. It's available in two sizes to best fit your needs: � The Easergy P3 Standard combines protection functions such as directional earth fault for feeder and motor protection in a one-box solution. � The Easergy P3 Advanced features a modular design that allows user-defined conventional protection and arc flash protection solutions in both new and existing power distribution systems. Easergy products are designed to be user friendly, a feature that is proven in our customer reports day after day. You'll benefit from features that include: � A complete set of protection functions, related to the application � Arc detection (Easergy P3 Advanced) � Dedicated circuit breaker control with single-line diagram, push buttons, programmable function key and LEDs, and a customizable alarm � Multilingual HMI for customized messaging � Settings tool relay management software for setting parameters, configuring, and network fault simulation � Both serial and Ethernet communication, including redundancy � IEC 61850 standard Ed.1 & Ed.2 8 | Easergy P3 Catalog schneider-electric.com Range description Selection guide Easergy P3 contains Two main devices, each with specific functions to address your needs in a one-box design, regardless of application. Easergy P3 Standard Easergy P3 Advanced Feeder Transformer Motor Generator Characteristics Phase current Measuring inputs Residual current Voltage Arc-flash sensor input Digital Input Output Analogue Input Output Temperature sensor input Front port Nominal power supply Ambient temperature, in service Communication Rear ports RS232, IRIG/B, RS485, Ethernet IEC61850 ed1 & ed2 IEC 60870-5-101 & 103 DNP3 over Ethernet DNP3 serial Protocols Modbus serial Modbus over Ethernet Ethernet IP DeviceNet Profibus DP SPAbus Redundancy protocols (RSTP/PRP) Others Control Logic (Matrix + Logic equation) Withdrawable CT connector with shorting Remote HMI Hardware dimensions (W/H/D) P3U10 P3U20 P3U30 with directional O/C with voltage protection 1/5A CT (x3) 1/5A CT or 0.2/1A CT VT (x1) VT (x4) - 2 10 16 5 + SF 5 + SF 8 + SF - 0 or 4 (1) - 0 or 4 (1) - 0 or 8 or 12 (1) USB type B 24V dc or 48-230V ac/dc -40 to 60�C (-40 to 140�F) P3F30 with directional P3L30 line diff. & distance - P3M30 P3G30 - P3T32 with differencial P3M32 with differencial P3G32 with differencial 1/5A CT (x3) 1/5A CT (x6) 1/5A CT & 1A CT or 1A CT & 0.2A CT 1/5ACT (x2) & 1A CT or 1/5A CT & 1A CT & 0.2A CT VT (x4) VT (x4) 4 point sensor (1) (2) 4 point sensor (1) 6 to 36 6 to 16 10 to 21 + SF 10 to 13 + SF 0 or 4 (1) 0 or 4 (1) 0 or 8 or 12 (1) USB type B 24 to 48V dc or 110-240V ac/dc -40 to 60�C (-40 to 140�F) - - 1 object mimic 6 controlled + 2 monitored objects mimic 6 controlled + 2 monitored objects mimic 171 x 176 x 214(3) mm / 6.73 x 6.93 x 8.43 in - 264 x 177 x 208 mm / 10.39 x 6.97 x 8.19 in (1) Depends on optional module (2) Arc flash protection option not available on Easergy P3L30 (3) 226 mm (8.90 in) with ring-lug connectors schneider-electric.com Easergy P3 Catalog | 9 Range description Selection guide Standard (P3U) Advanced (P3x) Protection functions ANSI code P3U10 P3U30 P3U20 P3F30 P3L30 P3M30 P3M32 P3G30 P3G32 P3T32 Distance Under-impedance Fault locator Overfluxing Synchro-check Undervoltage Positive sequence undervoltage Stator earth-fault detection Directional active underpower Phase undercurrent Temperature monitoring Loss of field Under-reactance Negative sequence overcurrent (motor, generator) Cur. unbalance, broken conductor Incorrect phase sequence Excessive start time, locked rotor Thermal overload Phase overcurrent Earth fault overcurrent Breaker failure Switch On To Fault (SOTF) Capacitor bank unbalance Voltage dependant overcurrent Overvoltage Capacitor overvoltage Neutral voltage displacement CT supervision VT supervision Stator earth fault Frequent start inhibition Directional phase overcurrent Directional earth-fault o/c Transient intermittent Magnetizing inrush detection Fifth harmonic detection Pole slip Auto-recloser Over or under frequency Rate of change of frequency Under frequency Lockout Line differential Machine differential Transformer differential Programmable stages Arc-flash detection stages Cold load pick-up Programmable curves Setting groups (3) 21 21G 21FL 24 25 27 27P 27TN/64G 32 37 38/49T 40 21/40 46 46BC 47 48/51LR 49 50/51 50N/51N 50BF 50HS 51C 51V 59 59C 59N 60 60FL 64S 66 67 67N 67NI 68F2 68H5 78PS 79 81 81R 81U 86 87L 87M 87T 99 - - 1 12 (0)(1) - 2 1 1 1 3 5 1 1 1 1 3 1 1 3 1 1 1 5 1 8 1 3 4 1 2 3 2 1 12 (1) - 2 1 1 1 3 5 1 1 1 1 3 1 3 1 1 1 4 3 1 1 1 5 2/2 1 2 1 8 1 3 4 1 2 3 2 12 (1) - - 1 1 3 5 1 1 2 1 3 1 2 1 1 4 3 1 1 1 5 2/2 1 2 1 8 8 1 3 4 1 1 2 3 2 12 (1) - - 1 1 3 5 1 1 2 1 3 1 2 1 1 4 3 1 1 1 5 2/2 1 2 1 2 8 1 3 4 2 3 2 1 12 (1) - 2 1 1 1 3 5 1 1 2 3 2 1 1 1 4 3 1 1 2/2 1 2 1 8 8 1 3 4 2 3 2 1 12 (1) - 2 1 1 1 3 5 1 1 2 3 2 1 1 1 4 3 1 1 2/2 1 2 1 2 8 8 1 3 4 2 1 2 3 2 1 2 12 (1) 1 2 2 1 3 5 1 1 2 1 3 2 1 1 1 4 3 1 1 1 2/2 1 2 1 8 8 1 3 4 2 1 2 3 2 1 2 12 (1) 1 2 2 1 3 5 1 1 2 1 3 2 2 1 1 4 3 1 1 1 2/2 1 2 1 2 8 8 1 3 4 1 2 3 2 12 (1) - 2 1 3 5 1 1 2 3 2 2 1 4 3 1 1 2/2 1 2 1 2 8 8 1 3 4 (0) No temperature sensors for P3U10 and 12 optional for P3U20 (1) Using external RTD module (2) P3U10 and P3U20 offer one voltage input. Function availability depends on the connection of the voltage input (3) Not all protection functions have 4 setting groups. See details in the manual. 10 | Easergy P3 Catalog schneider-electric.com Range description Selection guide Control functions Switchgear control and monitoring Switchgear monitoring only Programmable switchgear interlocking Local control on single-line diagram Local control with O/I keys Local/remote function Function keys Custom logic (logic equations) Control with Smart App Measurement RMS current values RMS voltage values RMS active, reactive and apparent power Frequency Fundamental frequency current values Fundamental frequency voltage values Fundamental frequency active, reactive and apparent power values Power factor Energy values active and reactive Energy transmitted with pulse outputs Demand values: phase currents Demand values: active, reactive, apparent power and power factor Min and max demand values: phase currents Min and max demand values: RMS phase currents Min and max demand values: active, reactive, apparent power and power factor Maximum demand values over the last 31 days and 12 months: active, reactive, apparent power Minimum demand values over the last 31 days and 12 months: active, reactive power Max and min values: currents Max and min values: voltages Max and min values: frequency Max and min values: active, reactive, apparent power and power factor Harmonic values of phase current and THD Harmonic values of voltage and THD Voltage sags and swells Logs and Records Sequence of event record Disturbance record Tripping context record Monitoring functions Trip circuit supervision (ANSI 74) Circuit breaker monitoring Relay monitoring (1) Function available on both sets of CT inputs Standard (P3U) P3U10 P3U30 P3U20 1/6 6 2 2 2 2 - - - - 1 1 1 1 Advanced (P3x) P3F30 P3L30 6 6 2 2 2 2 1 1 1 1 P3M30 6 2 2 1 1 P3M32 6 2 2 (1) (1) (1) 1 1 P3G30 6 2 2 1 1 P3G32 6 2 2 (1) (1) (1) 1 1 P3T32 6 2 2 (1) (1) (1) 1 1 schneider-electric.com Easergy P3 Catalog | 11 Range description Selection guide by application Arc flash application Busbar arc protection � Arc protection, activated by overcurrent and light signals, or light signals alone Centralized busbar arc protection De-centralized busbar arc protection DM105536 DM105535 P3F30 P3G30 P3T32 P3G32 P3F30 P3G30 P3T32 P3G32 � Up to 4 light point sensors to monitor the busbar P3F30 P3T32 P3M30 P3M32 � Up to 4 light point sensors in each relay � Transmission of light detection signals via digital I/O or IEC 61850 GOOSE messages Zone arc protection � Up to 8 arc protection stages in each relay DM105537 Zone 1 P3F30 P3G30 P3T32 P3G32 Zone 1 light detection signal Zone 2 Zone 3.1 P3F30 P3T32 Zone 3.2 P3M30 P3M32 � Light detection in zone 1: signal sent to upstream relay for tripping � Light detection in zone 2: incomer Easergy P3 trips, if fault confirmed by overcurrent � Light detection in zone 3: corresponding outgoing Easergy P3 trips, if fault confirmed by overcurrent 12 | Easergy P3 Catalog schneider-electric.com Range description Selection guide by application Feeder/incomer application Outgoing protection � Feeder overcurrent protection � Feeder overload protection Protection of low-capacitance feeders in impedance-earthed or solidly-earthed neutral systems Protection of high-capacitance feeders in impedance-earthed or compensated or isolated neutral systems Protection of feeders with metering DM105538 DM105539 DM105540 P3U10 P3U20 P3U30 P3F30 � Feeder earth-fault overcurrent P3U10 P3U20 P3U30 P3F30 � Directional earth-fault overcurrent � Transient intermittent earth-fault Incomer protection � Busbar overcurrent protection Incomer protection without voltage monitoring DM105542 DM105541 P3U10 P3U20 P3U30 P3F30 P3U10 P3U20 P3U30 P3F30 P3U30 P3F30 � Power and energy measurement � Min and max demand values over the last 31 days and 12 months Incomer protection with voltage and frequency monitoring DM105543 P3U30 P3F30 � Earth-fault overcurrent Incomer protection with power quality monitoring � Neutral voltage displacement protection for isolated system Parallel incomer protection � Under/over voltage � Frequency, rate of change of frequency DM105545 DM105544 P3U30 P3F30 P3U30 P3F30 P3U30 P3F30 � Voltage and frequency min and max values � Voltage harmonic values and THD � Voltage sags and swells � Directional phase overcurrent � Directional earth-fault overcurrent schneider-electric.com Easergy P3 Catalog | 13 Range description Selection guide by application Feeder/incomer application Line protection � Overcurrent and earth-fault protection (directional and non-directional) � Feeder overload protection Overhead line protection Incomer protection with fault locator Line protection with line differential and distance functions DM105546 DM105547 DM105548 P3U30 P3F30 P3L30 � Recloser � Feeder fault locator P3F30 � Incomer fault locator P3L30 � Line differential protection � Distance protection 14 | Easergy P3 Catalog schneider-electric.com Range description Selection guide by application Motor application Motor protection � Motor overcurrent and earth-fault overcurrent � Thermal overload � Motor start-up supervision � Motor restart inhibition Motor protection without voltage monitoring Motor protection with voltage monitoring Motor protection with differential function DM105549 DM105550 DM105551 P3U20 P3U30 P3M30 RTD module P3U30 P3M30 P3M32 � Temperature measurement (stator, bearings) � Undervoltage protection � Differential protection Motor-transformer unit protection � Motor-transformer overcurrent � Transformer earth-fault overcurrent � Thermal overload � Motor start-up supervision � Motor restart inhibition � External trip from thermostat/Buchholz Motor-transformer unit protection Motor-transformer unit protection with differential function DM105552 DM105553 P3U30 P3M30 26 63 49T RTD module � Temperature measurement (stator, bearings) � Motor neutral point displacement P3M32 26 63 49T � Differential protection � Motor earth-fault overcurrent schneider-electric.com Easergy P3 Catalog | 15 Range description Selection guide by application Transformer application Transformer feeder protection � Transformer overcurrent and earth-fault overcurrent protection � Thermal overload protection � External trip from thermostat/Buchholz Transformer feeder protection Transformer feeder protection without voltage monitoring Transformer feeder protection with voltage monitoring DM105554 DM105555 DM105556 P3U10 P3U20 P3U30 26 63 49T P3F30 P3U20 P3U30 26 63 P3F30 RTD module � Directional earth-fault overcurrent for impedance earthed or compensated neutral systems � Temperature measurement (ambient, oil) Transformer feeder protection with additional current measurement P3U30 26 63 49T P3F30 � Over and undervoltage protection Transformer feeder protection with differential function DM105557 DM105558 DM105559 P3F30 26 63 49T � Tank earth-leakage protection P3F30 26 63 49T P3T32 26 63 49T � Earth-fault overcurrent on the secondary side � Differential protection � Restricted earth-fault protection (high impedance) 16 | Easergy P3 Catalog schneider-electric.com Range description Selection guide by application Transformer application Transformer incomer protection � Busbar overcurrent protection � Inter-trip from primary CB protection Transformer incomer protection without voltage monitoring Transformer feeder protection with voltage monitoring DM105560 DM105561 DM105562 P3U10 P3U20 P3U30 P3F30 P3U10 P3U20 P3U30 P3F30 P3U30 P3F30 � Transformer earth-fault overcurrent � Earth-fault overcurrent for transformer and back-up protection Parallel transformer incomer protection � Over and undervoltage protection � Power and energy measurement � Min and max demand values over the last 31 days and 12 months Transformer incomer protection with differential function overcurrent DM105563 DM105564 P3U30 P3F30 P3U30 P3F30 � Directional phase overcurrent P3T32 � Transformer differential overcurrent � Restricted earth-fault overcurrent (high impedance) schneider-electric.com Easergy P3 Catalog | 17 Range description Selection guide by application Generator application Small generator transformer unit protection � Overcurrent protection of the supplied network � Voltage and frequency monitoring � External trip from thermostat/Buchholz Protection of a stand-alone generator-transformer unit DM105565 26 63 49T P3U30 P3G30 DM105566 26 63 49T P3U30 P3G30 � Earth-fault overcurrent protection of the supplied network Note: monitoring of generator insulation must be ensured by another device � Earth-fault overcurrent protection of the generator � Earth-fault overcurrent protection of the supplied network Protection of a generator-transformer unit coupled to another source DM105568 DM105567 26 63 49T P3U30 P3G30 26 63 49T P3G30 � Earth-fault overcurrent protection of the transformer � Neutral voltage displacement to detect transformer earth-fault when CB is open � Synchro-check Note: monitoring of generator insulation must be ensured by another device � Earth-fault overcurrent protection of the generator and the transformer � Neutral voltage displacement to detect transformer earth-fault when CB is open � Synchro-check 18 | Easergy P3 Catalog schneider-electric.com Range description Selection guide by application Generator application Mid-size generator protection � Under-impedance � Loss of field � Voltage and frequency monitoring Protection of a generator coupled to another source Generator protection with differential function Generator-transformer unit protection with differential function DM105569 DM105570 DM105571 P3G30 P3G32 26 63 49T P3G32 � Earth-fault overcurrent protection of the generator when coupled � Neutral voltage displacement to detect generator earth-fault when CB is open � Synchro-check � Stator earth-fault detection � Differential protection � Stator earth-fault detection � Differential protection � Restricted earth-fault protection (high impedance) schneider-electric.com Easergy P3 Catalog | 19 Range description Selection guide by application Capacitor application Capacitor bank protection � Capacitor bank overcurrent and earth-fault protection � Capacitor bank overload protection Capacitor bank protection without voltage monitoring Capacitor bank protection with voltage monitoring Protection of harmonic filters DM105572 DM105573 DM105574 P3U10 P3U20 P3U30 P3F30 P3U30 P3U10 P3U20 P3U30 � Capacitor overvoltage protection, based on current measurement and harmonics � Current harmonic values and THD � Capacitor bank unbalance � Overvoltage � Current and voltage harmonic values and THD � Overvoltage � Capacitor bank unbalance � Capacitor overvoltage protection, based on current measurement and harmonics � Current harmonic values and THD 20 | Easergy P3 Catalog schneider-electric.com DM105575 Range description Communication SCADA system HMI/ SCADA Serial link Relay 1 Daisy chain Relay 2 Connection to SCADA using serial line Relay n (n max= 32) This architecture allows you to connect HMI/SCADA to a set of Easergy protection relays using a multi-drop serial communication link with master-slave communication. Available protocols: � Modbus RTU � IEC 60870-5-101 � IEC 60870-5-103 � DNP3 � DeviceNet � Profibus � SPAbus Time synchronisation protocol: � IRIG-B � Minute pulse HMI/ SCADA Ethernet switch Ethernet Network Ethernet switch SubNetwork Connection to SCADA using Ethernet This architecture allows you to connect a set of Easergy protection relays directly to an Ethernet network. Available protocols: � IEC 61850 � IEC 60870-5-101 � DNP3 � Modbus � EtherNet/IP Note: It is possible to mix on the same Ethernet network the IEC 61850 protocol with any of the 4 other protocols. This allows you to use the GOOSE messages between relays together with another protocol for communication to SCADA. It is also possible to connect an Easergy relay to 2 different control systems, using the same Ethernet communication port and IEC 61850 protocol for one of them and any available protocol for the other one. The Easergy P3 relay handles the IEC 61850 station bus, in compliance with standards IEC 61850-6, 7-1, 7-2, 7-3, 7-4 and 8-1 Ed.1 or Ed.2, according to configuration. Other available Ethernet protocols: � FTP for file transfer � SNTP for time synchronization � HTTP for web server DM105576 schneider-electric.com Easergy P3 Catalog | 21 DM102975 DM105575 Range description Communication Example of communication Panel HMI Ethernet switch Ethernet GOOSE messages GOOSE messages Easergy Pro Architecture example 1 Switchboard internal network This architecture allows fast GOOSE communication between Easergy protection relays of the switchboard, thus avoiding costly wiring. Typical uses are logic discrimination, load shedding, etc. In addition, a panel HMI featuring a web browser can be used to monitor and control the entire switchboard. A spare connection on the panel Ethernet switch can also be provided for connecting the Easergy Pro. HMI/ SCADA Serial link Relay 1 Daisy chain Relay 2 Relay n (n max= 32) Architecture example 2 Connection to SCADA using serial lines and legacy protocols This architecture allows you to connect HMI/SCADA to a set of Easergy protection relays using a multi-drop serial communication link with master-slave communication protocols such as Modbus-RTU, DNP3, or IEC 61870-5-103. The RS485 serial communication port of the Easergy protection relay enables simple daisy chaining wiring thanks to its 2 RJ45 connectors, suited for 2-wire or 4-wire cabling. A termination module is plugged into the last connection. As an alternative, the fiber optic serial communication port can be used. HMI/ SCADA Ethernet switch Ethernet Network Ethernet switch Architecture example 3 Connection to HMI/SCADA using Ethernet with redundant paths When using an Ethernet infrastructure for the system network, redundant paths are often created. This is usually a deliberate action to improve communication availability, but can also result from non-mastered and overly complicated network architectures. Redundant paths, however, can result in loops that are not compatible with normal Ethernet operation because they permit frames to propagate endlessly, inducing a phenomenon known as "frame storm." Using such network topologies therefore requires the use of special management techniques. SubNetwork DM105576 22 | Easergy P3 Catalog schneider-electric.com DM105577 Range description Communication SCADA system HMI/ SCADA Ethernet switch Ethernet switch Ethernet switch RSTP (Rapid Spanning Tree Protocol) The principle of RSTP is to virtually cut all links that are not necessary at a given time, changing the meshed topology into a tree topology. The main advantage of RSTP is that it is widespread and works on any network topology. On the other hand, RSTP takes milliseconds or seconds to reconfigure the network in case of network interruption. Ethernet switch HMI/ SCADA Network A Network B PRP (Parallel Redundancy Protocol) The principle of PRP is to transmit frames in parallel on two independent network infrastructures: A and B. The receiving device is in charge of eliminating the redundant frame if it is received. PRP features a 0 ms recovery time in case of failure. PRP is supported by Easergy P3 relays. DM105578 schneider-electric.com Easergy P3 Catalog | 23 Range description Protocol Real-time data Measurement Alarms and status Controls Time-stamped events Historical data Disturbance records Setting management Setting group change Protocol Real time data Measurement Alarms and status Controls Time-stamped events Historical data Disturbance records Sequence of event record files Setting management Setting group change Settings Communication Data exchanged between Easergy P3 and SCADA Ethernet ports IEC 61850 Ethernet/IP FTP - - - Serial Ports IEC 60870-5-103 DeviceNet Profibus SPAbus - - - - - - - - - 24 | Easergy P3 Catalog schneider-electric.com Range description Protocol Real-time data Measurement Alarms and status Controls Time-stamped events Setting management Setting group change Communication Data exchanged between Easergy P3 and SCADA Ethernet or Serial ports DNP3 IEC 60870-5-101 Modbus schneider-electric.com Easergy P3 Catalog | 25 DM105579 Range description eSetup Easergy Pro Easergy web-HMI Ethernet Easergy SmartApp Easergy Pro Safe Repository and Schneider Electric web Communication Engineering system and System configuration Engineering system eSetup Easergy Pro eSetup Easergy Pro can be connected to a single Easergy protection relay on the front USB port or to a group of Easergy protection relays via Ethernet. eSetup Easergy Set allows you to prepare the configuration of the relay without having any physical relay. For this purpose, eSetup Easergy Pro provides the latest version of the configuration description file directly from the web. Easergy SmartApp Easergy SmartApp can be connected to the Easergy protection relays using a Wi-Fi router. Easergy SmartApp is also connected to the safe repository, allowing you to access todocuments and store files downloaded from the relay. Easergy web-HMI In addition to eSetup Easergy Pro, most of the resources of the relay can be accessed with a standard web browser, using the web pages embedded into the relay. Safe Repository and Schneider Electric web .icd file System configurator System configuration according to IEC 61850 The methodology described in IEC 61850-6 standard can be applied with Easergy protection relays to build a protection and control system based on this standard. .icd file When the configuration of an Easergy protection relay is done, setting tool can generate IED capability file. This file can be used by the system configurator. eSetup Easergy Pro DM105580 26 | Easergy P3 Catalog schneider-electric.com Range description Communication Arc flash protection system by network communication Arc flash protection system: Application example In this application example, the arc flash sensor for zone 4.1 is connected to Device 1. If the arc flash sensor awakens and simultaneously Device 3 sends a current signal, the zone 4.1 is isolated by the outgoing feeder breaker. The arc flash sensor for zone 4.2 is connected to Device 2 and operates the same way. The arc flash sensors for zone 3 are connected to Device 1, 2, or 3. If a sensor awakens in zone 3, the light-only signal is transferred to Device 3, which then trips the main circuit breaker. An eventual arc flash fault in zone 1 or 2 does not necessarily activate the current element in Device 2. However, arc detection can be achieved by using the light-only principle. If an arc flash occurs in cable termination, zone 1, or zone 2, the fault is cleared by the upstream circuit breaker. ZONE 1 DM105581 = Arc Sensor ZONE 2 ZONE 3 ZONE 4.1 ZONE4.2 schneider-electric.com Ethernet IEC 61850 with GOOSE message Easergy P3 Catalog | 27 Easergy P3 Standard 28 | Easergy P3 Catalog schneider-electric.com Easergy P3 Standard Presentation 30 Functional view 32 Base unit presentation 35 Local HMI 35 Rear panel connections 36 Base unit dimensions 37 Dimensions 37 Cut-out and mounting 37 Base unit characteristics 38 Technical characteristics 38 Environmental characteristics 39 Communication protocols 41 Programmable stages 42 Circuit breaker control 43 Connection diagram 44 Model selection 47 schneider-electric.com Easergy P3 Catalog | 29 Easergy P3 Standard Presentation The Easergy P3 Standard protection relay has been developed to meet your standard protection needs for building, distribution utilities, and industrial applications. Thanks to its optimized and flexible design, the Easergy P3 Standard provides an excellent solution for various protection applications. The user-friendly Easergy P3 Standard brings greater efficiency to your operations by enabling rapid ordering, configuration, and operations for an unparalleled digital experience Easergy P3 Standard at a glance Universal � All-in-one box with feeder, transformer, and motor protections � All communication protocols embedded on serial and Ethernet links including IEC 61850 ed.1 and ed. 2 Robust � Best-in class reliability based on 100+ years of experience in Sepam, MiCOM and Vamp relays � Strong tests performed in international laboratories � Compliant to IEC electro-mechanical standards Efficient and connected � Easy to order with 10 standard configurations delivered off the shelf in less than 7 days (location dependent) � Easy to configure with the unique eSetup Easergy Pro setting software � Easy to test with the virtual simulation test for direct injection of current and voltage from eSetup Easergy Pro � Easy to install with withdrawable rear connectors with CT shortening � Easy to use and maintain with the embedded web-HMI and Easergy SmartApp for direct access on site via your laptop, smartphone, or tablet. PM106572 Easergy P3 Standard with panel seal cover REL52833 30 | Easergy P3 Catalog schneider-electric.com Easergy P3 Standard Presentation DM105529 Easergy P3 is designed to cover all the standard applications with only one device: the Universal Protection. U Feeder U U U U U Capacitor M Motor Feeder Transformer Easergy P3 Standard is available in 3 models: Model Communication Easergy P3U10 � 4 CT / 1VT � 2 DI / 5 DO Stand-alone device, without communication ports Easergy P3U20 � 4 CT / 1VT � 10 DI / 5 DO Easergy P3U30 � 4 CT / 4VT � 16 DI / 8 DO Open communication protocols on serial or Ethernet links, with IEC 61850 Open communication protocols on serial or Ethernet links, with IEC 61850 Main advantages Simplicity, while allowing the latest features, like single-line diagrams (mimics), programmable protection stages, logics and function keys Openness to IEC 61850, while keeping the core functionnalities of Easergy P3 Standard relay Wide scope of possibilities, with the directional protection, synchro-check, fault location, and increased number of input and outputs A common set of functions extends the possibilities of protection and control: � Single-line diagrams (mimic) in the display � Programmable protection stages � Programmable logics � 2 programmable function keys � Synchro-check function � Direct-access USB port � Up to 6 objects controlled schneider-electric.com Easergy P3 Catalog | 31 DM105583 Easergy P3 Standard Functional view Easergy P3U10 HMI interface Function key F1 0 1 Control buttons LED F1 ON LED A LED C LED E LED G Programmable Logic Inputs AND TIMER Setting groups:4 H2/H5 Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V F2 LED F2 Service LED B LED D LED F LED H USB Local Port OR COUNTER XOR Output SOTF 79 74 86 60 99 CLPU 48 37 51LR 66 REL52822 59C 50BF 59N 50 67NI 51 67N 51C 50N 49 50G 51N 46 51G I1 / I2 / I3 Io V/V0 Analog measurement card Current input Voltage input I1 I2 I3 Io - V1 - - - X3 Connector DI1 DI2 SF T1 T2 T3 T4 A1 Power Supply eSetup Easergy Pro Circuit Breaker controls 32 | Easergy P3 Catalog schneider-electric.com DM105584 RS232 RS232 RS232 Easergy P3 Standard Functional view Easergy P3U20 HMI interface Function key F1 0 1 Control buttons LED F1 ON LED A LED C LED E LED G Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V F2 LED F2 Service LED B LED D LED F LED H USB Local Port OR COUNTER XOR Output Setting groups:4 H2/H5 SOTF 79 74 CLPU T 38 E 49T M P 86 60 99 Comm. interface - X4 Protocols � Modbus � DNP3.0 � IEC-103 � SPAbus RS485 48 37 51LR 66 REL52822 eSetup Easergy Pro Comm. interface - X4 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - X4 Redundancy LC LC Protocols � RSTP � IEC 61850 � PRP � Modbus Two protocols at the same time WebServer � DNP3.0 � IEC-101 � Ethernet/IP OR Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - X4 LC Two protocols at the same time RS232 + WebServer IRIG-B Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - X4 Two protocols at the same time WebServer RS232 + IRIG-B 59C 50BF 59N 50 67NI 51 67N 51C 50N 49 50G 51N 46 51G I1 / I2 / I3 Io V/V0 Analog measurement card Current input Voltage input I1 I2 I3 Io - V1 - - - X4 Connector DI3 DI4 DI5 DI6 DI7 DI8 DI9 DI10 X3 Connector DI1 DI2 SF T1 T2 T3 T4 A1 Power Supply Other type of controls Other type of controls Circuit Breaker controls REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52812 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 schneider-electric.com Easergy P3 Catalog | 33 DM105585 RS232 RS232 RS232 Easergy P3 Standard Functional view Easergy P3U30 HMI interface Function key F1 0 1 Control buttons LED F1 ON LED A LED C LED E LED G Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V F2 LED F2 Service LED B LED D LED F LED H USB Local Port OR COUNTER XOR Output Setting groups:4 H2/H5 SOTF 79 74 CLPU T 38 E 49T M P 86 60 99 Comm. interface - X4 Protocols � Modbus � DNP3.0 � IEC-103 � SPAbus RS485 48 37 51LR 66 REL52822 eSetup Easergy Pro Comm. interface - X4 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - X4 Redundancy LC LC Protocols � RSTP � IEC 61850 � PRP � Modbus Two protocols at the same time WebServer � DNP3.0 � IEC-101 � Ethernet/IP OR Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - X4 LC Two protocols at the same time RS232 + WebServer IRIG-B Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - X4 Two protocols at the same time WebServer RS232 + IRIG-B 67 21FL 37P 50BF 50 51 51C 67NI 67N 59C X5 Connector DI13 DI16 59N T5 T6 T7 DI11 DI12 DI14 DI15 81R 25 X4 Connector 81 DI3 DI4 DI5 DI6 DI7 DI8 DI9 DI10 81U 50N 49 50G 59 51N 46 51G 27 X3 Connector DI1 DI2 SF T1 T2 T3 T4 A1 I1 / I2 / I3 Io V / V0 V4 Analog measurement card Current input Voltage input I1 I2 I3 Io V1 V2 V3 V0 Power Supply Other type of controls Other type of controls Circuit Breaker controls REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52812 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 34 | Easergy P3 Catalog schneider-electric.com DM105586 Easergy P3 Standard Base unit presentation Local HMI Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Single-line diagram of the power system Comprehensive data for fast and easier operation All the data required for a local equipment operation may be displayed on demand: � Display the single-line diagram and freely assignable analog values � Display of all measurements � Display of operation and alarm messages � Display and setting of all parameters � Entry of password to protect parameter and protection settings Ergonomic data presentation � Keypad keys identified by pictograms for intuitive navigation � Graphical 128x64 LCD screen to display any character or symbol � Excellent display quality under all lighting conditions � Control buttons (0/1) to operate the circuit breaker and/or other controlled object � 8 freely programmable LEDs to identify easily the message showed � Labels are printed on a transparent film allowing customization of the relay � Programmable function key (F1 / F2) PM106367 Front panel: Control and push-buttons INFO push-button for viewing additional information, entering the password view, and adjusting the LCD contrast F1 Programmable function push-button F2 Programmable function push-button ENTER push-button for activating or OK confirming a function UP navigation push-button for moving up in the menu or increasing a numerical value DOWN navigation push-button for moving down in the menu or decreasing a numerical value LEFT navigation push-button for moving backwards in a parallel menu or selecting a digit in a numerical value RIGHT navigation push-button for moving forwards in a parallel menu or selecting a digit in a numerical value O Circuit breaker OFF push-button 128 x 64 LCD Object control buttons Local port Navigation push-buttons LED indicators Circuit breaker ON push-button HOME/CANCEL push-button for returning to the previous menu. To return to the first menu item in the main menu, press the button for at least three seconds Working language All the texts and messages displayed on the Easergy P3U are available in two languages at the same time. Consult us for availability. schneider-electric.com Easergy P3 Catalog | 35 Easergy P3 Standard Rear panels views Base unit presentation Rear panel connections PM106500 PM106501 PM106338 Easergy P3U10 Withdrawable connectors Easergy P3U20 Easergy P3U30 DM105587 DM105588 PM106500 Optional terminal X1: Pluggable screw clamp connector Optional terminal X1: Pluggable ring-lug connector 36 | Easergy P3 Catalog schneider-electric.com Easergy P3 Standard Base unit dimensions Weight (maximum) Easergy P3U10 / P3U20 / P3U30 2.5 Kg (5.519 Ib) Degree of protection (IEC 60529) IP54 Front panel / IP20 Rear side With screw connector With ring-lug connector A 214 mm / 8.43'' B 192 mm / 7.6'' 226 mm / 8.90'' 204 mm / 8.0'' Cut-out and mounting Cut-out accuracy must be complied with to ensure good withstand. DM105590 mm in 103.5.225 09..3265 12.81.25 09.3.57 51.3497 41.2702 154.649.541.2966 2 09.3.57 Panel mounting 0.014.0--100.39 DM105638 A 2.5 155 0.1 6.10 5.0 0.2 Easergy OK F2 F1 O I 124.5 4.90 137 B 5.39 With screw connector With ring-lug connector A 214 mm / 8.43'' B 147 mm / 8.8'' 226 mm / 8.90'' 159 mm / 6.2'' DM105639 Projection mounting with the raising frame REL52834 A 110 4.3 B 137 5.39 124.5 4.90 2.5 0.1 Raising frame REL52834 Raising frame REL52834 schneider-electric.com Easergy P3 Catalog | 37 Easergy P3 Standard Base unit characteristics Technical characteristics Analog inputs Phase Current Input 5A CT Configurable for CT secondaries 1 to 10A Residual Current Input (I0) 5A CT Configurable for CT secondaries 0.1 to 10A Residual Current Input (I0) 1A CT Configurable for CT secondaries 0.1 to 10.0A Residual Current Input (I0) 0.2A CSH sensor Configurable for CT secondaries 0.1 to 10.0A Voltage Input Configurable for VT secondaries 50 to 120V Analog temperature input and Analog output Type of temperature sensor Maximum distance between sensor and module Analog Output Minimum current Maximum current Operating temperature: Power supply REL52811 / REL52812 REL52813 REL52814 Measuring range Input Impedance Consumption 0.05 � 250 A 0.003 Ohm 0.075 VA 0.015 � 50 A 0.003 Ohm 0.075 VA 0.003 � 10 A 0.02 Ohm 0.02 VA 0.0006 � 2 A 0.02 Ohm 0.02 VA 0.5 � 190 V n.a. (100 V / 110 V) < 0.5 VA Rated thermal withstand 20 A (Continuously) 20 A (Continuously) 4 A (Continuously) 0.8 A (Continuously) 250V (Continuously) 1-second overload 500 A 500 A 100 A 20 A n.a. 10-second overload 100 A 100 A 20 A 4 A 600 V Pt100 up to 2,000 m (1) Ni100 Ni120 up to 2,000 m (1) up to 2,000 m (1) 0 mA 20 mA 0�C (32�F) to +55�C (131�F) 24 to 230 Vac/dc, 50/60 Hz 24 Vdc 48 to 230 ac/dc, 50/60 Hz Cu10 up to 2,000 m (1) Digital Input Nominal operation voltage Typical switching threshold Input limit voltage Frequency Typical consumption Voltage withstand DI1 to DI16 At state 1 At state 0 Digital Output Type of contact Rated Voltage Continuous current AC Breaking capacity DC (L/R=40ms) Making capacity Minimum making capacity Typical operation time Contact material at 48 V dc at 110 V dc at 220 V dc < 0.5 s < 3.0 s Power supply Nominal Voltage Range Inrush current (DC) Power consumption Normal conditions Output relays activated Acceptable momentary outages (1) 78,750 in 24 to 230 V ac/dc 12 V dc 19.2 V dc < 10.0 V dc 45 to 65 Hz 110 to 230 V ac/dc 75 V dc 88 V dc < 60 V dc 45 to 65 Hz <4 mA (typical approx. 3 mA) 255 V ac/dc 220 to 230 V ac/dc 155 V dc 176 V dc < 140 V dc 45 to 65 Hz Control and Trip contact, Tx 250 V ac/dc 5 A 2.000 VA 1.15 A 0.5 A 0.25 A 30 A 15 A 100 mA @ 24 Vac/dc <8 ms AgNi 90/10 Signal contact, A1 250 V ac/dc 5 A 2.000 VA 1 A 0.3 A 0.15 A 30 A 15 A 100 mA @ 24 Vac/dc - AgNi 0.15 gold plated Signal Contact, SF 250 V ac/dc 5 A 2.000 VA 1 A 0.3 A 0.15 A 100 mA @ 24 Vac/dc - AgNi 0.15 gold plated 48 to 230 Vac/dc 24 Vdc -20% / +10% (40 to 253 Vac/dc) -20% / +20% (19.2 to 28.8 Vdc) 25 A with time constant of 1000 �s 25 A with time constant of 750 �s 15 A with time constant of 500 �s <15 W (<30 VA) <25 W (<50 VA) <50 ms (110 V dc) 38 | Easergy P3 Catalog schneider-electric.com Easergy P3 Standard Base unit characteristics Environmental characteristics Electromagnetic compatibility Emission tests Conducted Emitted Immunity 1 Mhz damped oscillatory wave Standard and test class/level IEC/EN 60255-26 (ed3) EN 55022, Class A / CISPR 22 EN 55011, Class A / CISPR 11 IEC/EN 60255-26 (ed3) IEC/EN 61000-4-18 Static discharge (ESD) IEC/EN 61000-4-2 Level 4 Emitted HF field Fast transients (EFT) Surge IEC/EN 61000-4-3 Level 3 IEC/EN 61000-4-4 Level 4 IEC/EN 61000-4-5 Level 3 Conducted HF field Power-frequency magnetic field Pulse magnetic field ac and dc voltage dips IEC/EN 61000-4-6 Level 3 IEC/EN 61000-4-8 IEC/EN 61000-4-9 Level 5 IEC/EN 61000-4-29, IEC/EN 61000-4-11 ac and dc voltage interruptions Voltage alternative component IEC/EN 61000-4-29, IEC/EN 61000-4-11 IEC/EN 61000-4-17 Mechanical robustness In operation Vibrations Shocks Seismic De-energized Vibrations Shocks Bump Standard and test class/level IEC 60255-21-1, Class II / IEC 60068-2-6, Fc IEC 60255-21-2, Class II / IEC 60068-2-27, Ea IEC 60255-21-3 Method A, Class II IEC 60255-21-1, Class II / IEC 60068-2-6, Fc IEC 60255-21-2, Class II / IEC 60068-2-27, Ea IEC 60255-21-2, Class II / IEC 60068-2-27, Ea Test value 0.15 � 30 MHz 30 � 1000 MHz �2.5kVp CM �2.5kVp DM �8 kV contact �15 kV air 80 - 2700 MHz, 10 V/m �4 kV, 5/50 ns, 5 kHz �2 kV, 1.2/50 �s, CM �1 kV, 1.2/50 �s, DM 0.15 - 80 MHz, 10 Vrms 300 A/m (continuous) 1000 A/m 1 � 3s 1000A/m, 1.2/50 �s 0% of rated voltage � ac: 0.5 cycle � dc: 10 ms 40% of rated voltage � ac: 10 cycles � dc: 200 ms 70% of rated voltage � ac: 25 cycles � dc: 500 ms 100% interruption � ac: 250 cycles � dc: 5 s 15% of operating voltage (dc) / 10 min Test value 1 Gn, 10 Hz � 150 Hz 10 Gn / 11 ms 2G horizontal / 1G vertical , 1�35 Hz 2 Gn, 10 Hz � 150 Hz 30 Gn / 11 ms 20 Gn / 16 ms schneider-electric.com Easergy P3 Catalog | 39 Easergy P3 Standard Base unit characteristics Environmental characteristics Environment tests In operation Dry heat Cold Damp heat, cyclic Standard and test class/level EN / IEC 60068-2-2, Bd EN / IEC 60068-2-1, Ad EN / IEC 60068-2-30, Db Damp heat, static EN / IEC 60068-2-78, Cab Change of temperature IEC / EN 60068-2-14, Nb In storage Dry heat Cold EN / IEC 60068-2-2, Bb EN / IEC 60068-2-1, Ab Test value 70�C (158�F) -40�C (-40�F) From 25�C (77�F) to 55�C (131�F) From 93% RH to 98% RH Testing duration: 6 days 40�C (104�F) 93% RH Testing duration: 10 days Lower temp -40�C (-40�F) Upper temp 70�C (158�F) 5 cycles 70�C (158�F) -40�C (-40�F) Environmental conditions Ambient temperature, in-service Ambient temperature, storage Relative air humidity Maximum operating altitude -40 � 60�C (-40 � 140�F) -40 � 70�C (-40 � 158�F) < 95%, no condensation allowed 2000 m (6561.68 ft) Safety Electrical safety tests Impulse voltage withstand Dielectric test Insulation resistance Protective bonding resistance Clearance and creepage distance Power supply burden Standard and test class/level IEC/EN 60255-27 IEC/EN 60255-27 IEC/EN 60255-27 IEC/EN 60255-27 Design criteria for distances as per IEC 60255-27 Annex C (pollution degree 2, overvoltage category 3) IEC 60255-1 Test value 5 kV, 1.2/50 �s, 0.5 J 1 kV, 1.2/50 �s, 0.5 J Communication 2 kV, 50 Hz 0.5 kV, 50 Hz Communication 40 | Easergy P3 Catalog schneider-electric.com PM106362 Easergy P3 Standard Communication protocols Easergy P3 Standard can be connected to networks, thus providing access to the following type of data: � Events � Status information � Measurements � Control commands � Clock synchronizing � Settings (SPA-bus and embedded SPA-bus only) Easergy SmartApp. Main protocols Easergy P3 Standard can be connected directly to serial and/or Ethernet protocols with two different protocols at the same time, selected by eSetup Easergy Pro software. Communication protocols: Communication ports: Serial protocols - RS232 / RS485 / serial Fiber Optic (*) port Modbus RTU DNP3.0 IEC 60870-5-101 IEC 60870-5-103 DeviceNet (*) ProfibusDP (*) SPA-Bus (*) Ethernet protocols RJ45 / LC port IEC61850 ed1 & ed2 Modbus TCP DNP3.0 IEC60870-5-101 Ethernet IP Redundancy � RSTP � PRP Two protocols at the same time Comm. interface - X4 LC LC WebServer Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - X4 LC RS232 + IRIG-B Two protocols at the same time WebServer Redundancy � RSTP � PRP Two protocols at the same time Comm. interface - X4 WebServer Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Protocols � Modbus � DNP3.0 � IEC-103 � SPAbus Comm. interface - X4 RS232 + IRIG-B Two protocols at the same time WebServer Comm. interface - X4 RS485 *Need external accessories to connect. Easergy web-HMI Redundancy protocols (RSTP or PRP) When the devices are connecting in Ethernet link and demand for higher availability, Easergy P3 Standard can use Rapid Spanning Tree Protocol (RSTP) or Parallel Redundancy Protocol (PRP) to recover from a network failure. Easergy P3 web-HMI A webserver is available in Easergy P3 Standard to get information from the device to monitor all data, send commands, and change protection settings. PM106576 schneider-electric.com Easergy P3 Catalog | 41 Easergy P3 Standard Programmable stages Programmable protection function Personalize your protection function Easergy P3 Standard allows you to create or personalize the protection function when you need to achieve specific levels of protection. There are now eight stages available to use with various applications. Each stage can monitor any analog (measured or calculated) signal and issue start and trip signals. Programmable stages extend the protection functionality of the manager series to a new level. The Programmable stage has the possibility of comparing two freely selectable signals between each other. Using this feature you can create a comparison function using the relay's own measured or calculated signals. One or both of the signals can be connected to the comparison function over GOOSE. For example, if four stages of frequency are not enough, it is possible to reach a maximum of 12 using programmable stages. Other examples include using the stages to issue an alarm when there are too many harmonics (THD) or indicating reverse power condition by GOOSE. . EM100170 42 | Easergy P3 Catalog schneider-electric.com Easergy P3 Standard Circuit breaker control With Easergy P3 Standard, you get intuitive functionality to protect your electrical network system. Main CB functions are: � Trip circuit supervision (ANSI 74) � CT/VT supervision (ANSI 60/60FL) � Latching (ANSI 86) � CB close/open order � Number of operations � Cumulative breaking current � Personalized functions Maximize circuit breaker control Easergy P3 Standard is a simple protection relay with a single-line diagram with control buttons (open and close), two personalized function keys, and eight configurable tricolor LEDs. You can manage the control without external or additional component. Example of implementation The schematic is structured for typical use in MV switchgears, 100% adapted for your use case. You are free to change the internal logic to adapt the Easergy P3 Standard to follow your needs. If a problem occurs, clear and complete information puts you able to make the right decisions immediately. MV network CT This electrical schematic can facilitate the IEC 61850 implementation because all the logics are determined by the protection unit that will make the decisions and if necessary can send GOOSE messages to other units. DM105591 HMI interface Function key F1 0 I Control buttons LED F1 ON LED A LED C LED E LED G Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V F2 LED F2 Service LED B LED D LED F LED H USB Local Port Inputs AND TIMER Latching contact ANSI 86 Trip control Order contact OR COUNTER Trip Circuit Supervision XOR Output Nominal voltage Alarm contact for Trip circuit failure T2 Close contact Order contact T3 0 1 Open/Close Mechanical command A1 T1 Digital Input 2 Digital Input 1 Trip circuit supervision Trip circuit supervision Trip circuit failure alarm DI 2 DI 1 52a CLOSE COIL OPEN COIL 52b Circuit Breaker schneider-electric.com Easergy P3 Catalog | 43 Easergy P3 Standard Connection diagrams Easergy P3U30 example DANGER HAZARD OF ELECTRIC SHOCK, ELECTRIC ARC OR BURNS - only qualified personnel should install this equipment. Such work should be performed only after reading this entire set of instructions. - NEVER work alone. - turn off all power supplying this equipment before working on or inside it. Consider all sources of power, including the possibility of backfeeding. - always use a properly rated voltage sensing device to confirm that all power is off. - start by connecting the device to the protective earth and to the functional earth. - screw tight all terminals, even those not in use. Failure to follow these instructions will result in death or serious injury. DM105593 Application with 3 phase CTs, 1 earth CT, 1 VT and CB control 1 0 3 20 4 DI1 V1 19 5 USB 18 6 DI2 Local Port V2 17 16 17 T1 V3 15 16 15 14 13 12 11 10 8 9 7 19 20 18 1 T2 X3 T3 T5 14 13 T6 12 11 X5 T7 10 T4 9 8 DI16 7 A1 DI15 Easergy DI14 6 5 SF P3U30 4 DI13 3 DI12 2 X1 DI11 1 2 I1 3 4 I2 5 6 I3 7 8 5 A 9 OR Io OR 10 1 A 14 DI10 13 DI9 12 11 DI8 10 DI7 9 8 DI6 X4 7 6 DI5 5 1 2 V4 3 X2 4 4 DI4 3 2 DI3 1 X4 COM Serial communication port 44 | Easergy P3 Catalog schneider-electric.com Easergy P3 Standard Connection diagrams Easergy P3U30 example DANGER HAZARD OF ELECTRIC SHOCK, ELECTRIC ARC OR BURNS - only qualified personnel should install this equipment. Such work should be performed only after reading this entire set of instructions. - NEVER work alone. - turn off all power supplying this equipment before working on or inside it. Consider all sources of power, including the possibility of backfeeding. - always use a properly rated voltage sensing device to confirm that all power is off. - start by connecting the device to the protective earth and to the functional earth. - screw tight all terminals, even those not in use. Failure to follow these instructions will result in death or serious injury. DM105594 Application with 3 phase CTs, 1 earth CT, 3 VTs, synchro-check and CB control 1 0 3 20 4 DI1 V1 19 5 USB 18 Local Port V2 6 DI2 17 16 17 T1 V3 15 16 15 14 13 12 11 10 8 9 7 19 20 18 1 T2 X3 T3 T5 14 13 T6 12 11 X5 T7 10 T4 9 8 DI16 7 A1 DI15 Easergy DI14 6 5 SF P3U30 4 DI13 3 DI12 2 X1 DI11 1 2 I1 3 4 I2 5 6 I3 7 8 5 A 9 OR Io OR 10 1 A 14 DI10 13 DI9 12 11 DI8 10 DI7 9 8 DI6 X4 7 6 DI5 5 1 2 V4 3 X2 4 4 DI4 3 2 DI3 1 X4 Redundant Ethernet Network - RSTP or PRP schneider-electric.com Easergy P3 Catalog | 45 Easergy P3 Standard Connection diagrams Easergy P3U30 example DANGER HAZARD OF ELECTRIC SHOCK, ELECTRIC ARC OR BURNS - only qualified personnel should install this equipment. Such work should be performed only after reading this entire set of instructions. - NEVER work alone. - turn off all power supplying this equipment before working on or inside it. Consider all sources of power, including the possibility of backfeeding. - always use a properly rated voltage sensing device to confirm that all power is off. - start by connecting the device to the protective earth and to the functional earth. - screw tight all terminals, even those not in use. Failure to follow these instructions will result in death or serious injury. DM105595 Application with 3 phase CTs, 1 earth CT, 4 VTs and CB control 1 0 3 20 4 DI1 V1 19 5 USB 18 Local Port V2 6 DI2 17 16 17 T1 V3 15 16 15 14 13 12 11 10 8 9 7 19 20 18 1 T2 X3 T3 T5 14 13 T6 12 11 X5 T7 10 T4 9 8 DI16 7 A1 DI15 Easergy DI14 6 5 SF P3U30 4 DI13 3 DI12 2 X1 DI11 1 2 I1 3 4 I2 5 6 I3 7 8 5 A 9 OR Io OR 10 1 A 14 DI10 13 DI9 12 11 DI8 10 DI7 9 8 DI6 X4 7 6 DI5 5 1 2 V4 3 X2 4 4 DI4 3 2 DI3 1 X4 Go to X2 Slot (pin 1 & 2) Redundant Ethernet Network - RSTP or PRP 46 | Easergy P3 Catalog schneider-electric.com Easergy P3 Standard PM106367 PM106367 PM106367 Model selection Selecting product Please, consult the "Ordering" section to choose specific characteristics in the relays for your system: P3U10 Standard application Page 106 P3U20 Standard application Page 107 P3U30 Standard application Page 108 Or use our web configuration tool: Go to web configurator schneider-electric.com Easergy P3 Catalog | 47 Easergy P3 Advanced 48 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Presentation 50 Functional view 52 Base unit presentation 59 Integrated arc flash protection 59 Local HMI 60 Rear panel 61 Remote HMI 63 Base unit dimensions 64 Dimensions 64 Cut-out and mounting 65 Base unit characteristics 66 Technical characteristics 66 Environmental characteristics 67 Communication 69 Communication protocols 69 Programmable stages 70 Circuit breaker control 71 Power quality measurements 72 Connection diagrams 73 Model selection 76 schneider-electric.com Easergy P3 Catalog | 49 Easergy P3 Advanced Presentation The Easergy P3 Advanced protection relay has been developed to cover demanding protection needs for building, distribution utilities, and industrial applications. Thanks to its wide scope of functionalities, the Easergy P3 Advanced range provides an excellent solution for your high-end protection applications. Protect your staff and equipment and ensure safer operations with Easergy P3 Advanced's built-in arc flash detection and protection functions. You will experience greater operational efficiency with rapid ordering, configuration, and operations for an unparalleled digital experience provided with Easergy P3. Easergy P3 Advanced at a glance Extended capabilities � Extended protection functions, including differential of line, transformer, motor, and generator � Arc flash detection � All communication protocols embedded on serial and Ethernet links, including IEC 61850 ed.1 and ed. 2 � Increased number of inputs and outputs Robust � Best-in class reliability based on 100+ years of experience in Sepam, MiCOM and Vamp relays � Strong tests performed in international laboratories � Compliant with IEC electro-mechanical standards Efficient and connected � Easy to configure with the unique eSetup Easergy Pro setting software � Easy to test with the virtual simulation test for direct injection of current and voltage from eSetup Easergy Pro � Easy to use and maintain with the embedded web-HMI and Easergy SmartApp for direct access on site via your laptop, smartphone, or tablet � Easy to install with withdrawable rear connectors with CT shortening PM106370 50 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Presentation DM105530 Easergy P3 is designed to cover a large scope of applications Line Di erential & Distance L U Feeder M M Motor Di erential G G Generator Di erential T Transformer Di erential Easergy P3 Advanced is designed in 7 models, per application: Model Function Easergy P3F 30 Feeder Protection Easergy P3L 30 Line Differential and Distance 30 Easergy P3M 32 Motor Protection Differential 30 Easergy P3G 32 Generator Protection Differential Easergy P3T 32 Transformer Differential A common set of functions extends the possibilities of protection and control: � Single-line diagrams (mimic) in the display � Programmable protection stages � Programmable logics � 2 programmable function keys � Synchro-check function � Direct-access USB port � Up to 6 objects controlled � Arc flash protection schneider-electric.com Easergy P3 Catalog | 51 Easergy P3 Advanced Functional view Easergy P3F30 DM105596b RS232 RS232 RS232 HMI interface I 0 Control buttons Function key F1 ON LED A LED C LED E LED G LED I LED K LED M LED F1 Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Service LED B LED D LED F LED H LED J LED L LED N LED F2 USB Local Port F2 OR COUNTER XOR Output Setting groups:4 H2/H5 38 49T 60 99 SOTF 79 74 86 CLPU AFD Comm. interface - Slot 9 T E Protocols RS232 M P � Modbus � DNP3.0 � IEC-103 � SPAbus Option card - Slot 6 Arc 1 A Arc 2 A Arc 3 A Arc 4 A OR 67 21FL 37P I/O card G - Slot 5 DI19 DI20 DI21 DI22 DI23 DI24 T25 T26 T27 T28 50BF 50 51 51C 49 46 59N 67NI I/O card G - Slot 4 DI13 DI14 DI15 DI16 DI17 DI18 T21 T22 T23 T24 81R I/O card G - Slot 3 67N 25 DI7 DI8 DI9 DI10 DI11 DI12 81 81U 50N 50G 59 51N 51G 27 T17 T18 T19 T20 I/O card G - Slot 2 DI1 DI2 DI3 DI4 DI5 D6 T13 T14 T15 T16 Analog measurement card - Slot 8 Current input Voltage input I1 I2 I3 Io1 Io2 V1 V2 V3 V0 Power Supply - Slot 1 T9 T10 T11 T12 T1 A1 SF Other types of control Arc sensor: See list of Accessories REL52801 to REL52810 Circuit Breaker controls Arc Flash sensors REL52822 eSetup Easergy Pro Comm. interface - Slot 9 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Redundancy LC LC Protocols � RSTP � IEC 61850 � PRP � Modbus Two protocols at the same time WebServer � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 LC RS232 + IRIG-B Two protocols at the same time � Ethernet/IP WebServer Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP RS232 + IRIG-B Two protocols at the same time WebServer REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52812 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 52 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Functional view Easergy P3M30 DM105597b RS232 RS232 RS232 HMI interface I 0 Control buttons Function key F1 ON LED A LED C LED E LED G LED I LED K LED M LED F1 Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Service LED B LED D LED F LED H LED J LED L LED N LED F2 USB Local Port F2 OR COUNTER XOR Output Setting groups:4 H2/H5 SOTF 38 49T 60 99 74 86 CLPU AFD 37 66 48 51LR 67 37P Comm. interface - Slot 9 T E Protocols RS232 M P � Modbus � DNP3.0 � IEC-103 � SPAbus Option card - Slot 6 Arc 1 A Arc 2 A Arc 3 A Arc 4 A I/O card G - Slot 5 DI19 DI20 DI21 DI22 DI23 DI24 T25 T26 T27 T28 50BF 50 I/O card G - Slot 4 59N DI13 DI14 DI15 DI16 DI17 DI18 T21 T22 T23 T24 51 81R I/O card G - Slot 3 67N 25 DI7 DI8 DI9 DI10 DI11 DI12 51C 81 81U 50N 49 50G 59 51N 46 51G 27 T17 T18 T19 T20 I/O card G - Slot 2 DI1 DI2 DI3 DI4 DI5 D6 T13 T14 T15 T16 Analog measurement card - Slot 8 Current input Voltage input I1 I2 I3 Io1 Io2 V1 V2 V3 V0 Power Supply - Slot 1 T9 T10 T11 T12 T1 A1 SF Other types of control Arc sensor: See list of Accessories REL52801 to REL52810 M Circuit Breaker controls Arc Flash sensors OR REL52822 eSetup Easergy Pro Comm. interface - Slot 9 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Redundancy LC LC Protocols � RSTP � IEC 61850 � PRP � Modbus Two protocols at the same time WebServer � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 LC RS232 + IRIG-B Two protocols at the same time � Ethernet/IP WebServer Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP RS232 + IRIG-B Two protocols at the same time WebServer REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52812 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 schneider-electric.com Easergy P3 Catalog | 53 Easergy P3 Advanced Functional view Easergy P3M32 DM105598b RS232 RS232 RS232 HMI interface I 0 Control buttons Function key F1 ON LED A LED C LED E LED G LED I LED K LED M LED F1 Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Service LED B LED D LED F LED H LED J LED L LED N LED F2 USB Local Port F2 OR COUNTER XOR Output Setting groups:4 H2/H5 SOTF 60 99 74 86 CLPU 37 66 48 51LR 67 37P 38 49T AFD 87M Comm. interface - Slot 9 T E M P � Modbus � DNP3.0 � IEC-103 RS232 � SPAbus Option card - Slot 6 Arc 1 A Arc 2 A Arc 3 A Arc 4 A I/O card 4 - Slot 5 Slot reserved 50BF 50 I/O card 3 - Current input 59N IL1 IL2 IL3 Io3 51 81R I/O card G - Slot 3 67N 25 DI7 DI8 DI9 DI10 DI11 DI12 51C 81 81U 50N 49 50G 59 51N 46 51G 27 T17 T18 T19 T20 I/O card G - Slot 2 DI1 DI2 DI3 DI4 DI5 D6 T13 T14 T15 T16 Analog measurement card - Slot 8 Current input Voltage input IL1 IL2 IL3 Io1 Io2 V1 V2 V3 V0 Power Supply - Slot 1 T9 T10 T11 T12 T1 A1 SF Other types of control Arc sensor: See list of Accessories REL52801 to REL52810 M Circuit Breaker controls Arc Flash sensors OR REL52822 eSetup Easergy Pro Comm. interface - Slot 9 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Redundancy LC LC Protocols � RSTP � IEC 61850 � PRP � Modbus Two protocols at the same time WebServer � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 LC RS232 + IRIG-B Two protocols at the same time � Ethernet/IP WebServer Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP RS232 + IRIG-B Two protocols at the same time WebServer REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52812 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 54 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Functional view Easergy P3T32 DM105599b RS232 RS232 RS232 HMI interface I 0 Control buttons Function key F1 ON LED A LED C LED E LED G LED I LED K LED M LED F1 Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Service LED B LED D LED F LED H LED J LED L LED N LED F2 USB Local Port F2 OR COUNTER XOR Output Setting groups:4 H2/H5 SOTF 38 49T 60 99 74 86 CLPU AFD Comm. interface - Slot 9 T E Protocols RS232 M P � Modbus � DNP3.0 � IEC-103 � SPAbus Option card - Slot 6 Arc 1 A Arc 2 A Arc 3 A Arc 4 A 87T I/O card 4 - Slot 5 67 50BF 50 37P 24 59N Slot reserved I/O card 3 - Current input IL'1 IL'2 IL'3 Io3 81R 51 67N 25 81 81U 50N 49 50G 59 51N 46 51G 27 27P Analog measurement card - Slot 8 Current input Voltage input IL1 IL2 IL3 Io1 Io2 V1 V2 V3 V0 I/O card G - Slot 3 DI7 DI8 DI9 DI10 DI11 DI12 T17 T18 T19 T20 I/O card G - Slot 2 DI1 DI2 DI3 DI4 DI5 D6 T13 T14 T15 T16 Power Supply - Slot 1 T9 T10 T11 T12 T1 A1 SF Other types of control Arc sensor: See list of Accessories REL52801 to REL52810 Circuit Breaker controls Arc Flash sensors OR REL52822 eSetup Easergy Pro Comm. interface - Slot 9 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Redundancy LC LC Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 LC RS232 + IRIG-B Two protocols at the same time � Ethernet/IP WebServer Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Two protocols at the same time WebServer RS232 + IRIG-B REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52812 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 schneider-electric.com Easergy P3 Catalog | 55 Easergy P3 Advanced Functional view Easergy P3L30 DM105600b RS232 RS232 RS232 HMI interface I 0 Control buttons Function key F1 ON LED A LED C LED E LED G LED I LED K LED M LED F1 Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Service LED B LED D LED F LED H LED J LED L LED N LED F2 USB Local Port F2 OR COUNTER XOR Output Setting groups:4 H2/H5 38 49T 60 99 SOTF 79 74 86 CLPU 87L 67 21FL 37P 21 Comm. interface - Slot 9 T E Protocols RS232 M P � Modbus � DNP3.0 � IEC-103 � SPAbus Option card 1 - Slot 6 Device B Communication link I/O card G - Slot 5 DI19 DI20 DI21 DI22 DI23 DI24 T25 T26 T27 T28 50BF 50 51 51C 49 46 59N 67NI I/O card G - Slot 4 DI13 DI14 DI15 DI16 DI17 DI18 T21 T22 T23 T24 81R I/O card G - Slot 3 67N 25 DI7 DI8 DI9 DI10 DI11 DI12 81 81U 50N 50G 59 51N 51G 27 T17 T18 T19 T20 I/O card G - Slot 2 DI1 DI2 DI3 DI4 DI5 D6 T13 T14 T15 T16 Analog measurement card - Slot 8 Current input Voltage input I1 I2 I3 Io1 Io2 V1 V2 V3 V0 Power Supply - Slot 1 T9 T10 T11 T12 T1 A1 SF Other types of control Circuit Breaker control REL52822 eSetup Easergy Pro OR Comm. interface - Slot 9 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Redundancy LC LC Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 LC RS232 + IRIG-B Two protocols at the same time � Ethernet/IP WebServer Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP RS232 + IRIG-B Two protocols at the same time WebServer REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52825 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52826 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 56 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Functional view Easergy P3G30 DM105601b RS232 RS232 RS232 HMI interface I 0 Control buttons Function key F1 ON LED A LED C LED E LED G LED I LED K LED M LED F1 Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Service LED B LED D LED F LED H LED J LED L LED N LED F2 USB Local Port F2 OR COUNTER XOR Output Setting groups:4 H2/H5 SOTF 38 49T 60 99 74 86 CLPU AFD Comm. interface - Slot 9 T E Protocols RS232 M P � Modbus � DNP3.0 � IEC-103 � SPAbus Option card - Slot 6 Arc 1 A Arc 2 A Arc 3 A Arc 4 A 67 21B 37P I/O card G - Slot 5 DI19 DI20 DI21 DI22 DI23 DI24 T25 T26 T27 T28 50BF 50 I/O card G - Slot 4 59N DI13 DI14 DI15 DI16 DI17 DI18 T21 T22 T23 T24 81R 51 67N 25 27N 81 64G 81U 50N 49 50G 51V 59 51N 46 51G 40 27 32Q 27P Analog measurement card - Slot 8 Current input Voltage input I1 I2 I3 Io1 Io2 V1 V2 V3 V0 I/O card G - Slot 3 DI7 DI8 DI9 DI10 DI11 DI12 T17 T18 T19 T20 I/O card G - Slot 2 DI1 DI2 DI3 DI4 DI5 D6 T13 T14 T15 T16 Power Supply - Slot 1 T9 T10 T11 T12 T1 A1 SF Other types of control Arc sensor: See list of Accessories REL52801 to REL52810 G Circuit Breaker controls OR REL52822 eSetup Easergy Pro Comm. interface - Slot 9 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Redundancy LC LC Protocols � RSTP � IEC 61850 � PRP � Modbus Two protocols at the same time WebServer � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 LC RS232 + IRIG-B Two protocols at the same time � Ethernet/IP WebServer Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP RS232 + IRIG-B Two protocols at the same time WebServer REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52812 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 schneider-electric.com Easergy P3 Catalog | 57 Easergy P3 Advanced Functional view Easergy P3G32 DM105602b RS232 RS232 RS232 HMI interface I 0 Control buttons Function key F1 ON LED A LED C LED E LED G LED I LED K LED M LED F1 Programmable Logic Inputs AND TIMER Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Service LED B LED D LED F LED H LED J LED L LED N LED F2 USB Local Port F2 OR COUNTER XOR Output Setting groups:4 H2/H5 SOTF 38 49T 60 99 74 86 CLPU AFD Comm. interface - Slot 9 T E Protocols RS232 M P � Modbus � DNP3.0 � IEC-103 � SPAbus Option card - Slot 6 Arc 1 A Arc 2 A Arc 3 A Arc 4 A 87M 67 21B 37P I/O card 4 - Slot 5 Slot reserved 50BF 50 I/O card 3 - Current input 59N IL'1 IL'2 IL'3 Io3 81R 51 67N 25 27N 81 64G 81U 50N 49 50G 51V 59 51N 46 51G 40 27 32Q 27P Analog measurement card - Slot 8 Current input Voltage input IL1 IL2 IL3 Io1 Io2 V1 V2 V3 V0 I/O card G - Slot 3 DI7 DI8 DI9 DI10 DI11 DI12 T17 T18 T19 T20 I/O card G - Slot 2 DI1 DI2 DI3 DI4 DI5 D6 T13 T14 T15 T16 Power Supply - Slot 1 T9 T10 T11 T12 T1 A1 SF Other types of control Arc sensor: See list of Accessories REL52801 to REL52810 G Circuit Breaker controls OR REL52822 eSetup Easergy Pro Comm. interface - Slot 9 Redundancy Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Redundancy LC LC Protocols � RSTP � PRP Two protocols at the same time WebServer � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP LC RS232 + IRIG-B Two protocols at the same time WebServer Comm. interface - Slot 9 Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Two protocols at the same time WebServer RS232 + IRIG-B REL52820 Connect to RS232 port REL52816 REL52819 REL52821 Protocols Modbus DNP3.0 IEC-103 RS485 Protocols Modbus DNP3.0 IEC-103 SPAbus Protocols DeviceNet RS485 Serial Serial network OR REL52812 RS485 RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 OR REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 58 | Easergy P3 Catalog schneider-electric.com PM106502 DM102188 Easergy P3 Advanced Base unit presentation Integrated arc flash protection Easergy P3 Advanced measures fault current, and with arc protection, also light via arc sensor channels that provide monitoring for the whole switchgear. An arc flash is a mass of heat and pressure caused by a switchgear fault. It not only causes power outages but can also result in loss of business and extensive material damage. If an arc fault occurs in the switchgear, the arc protection system prevents the fault from spreading by tripping the circuit breaker within less than 10 ms. Easergy P3 Advanced relays can connect up to four arc flash sensors that have continuous self-supervision to check the sensor status. Arc flash sensors Easergy P3 Advanced 1 2 3 4 Example of application The four arc flash sensors can be installed in specific parts of the switchgear: 1. Busbars compartment 2. Circuit breaker compartment 3. Current/voltage transformers compartment 4. Cables connections compartment Cable 4 CB 2 DM105582 CB 2 IEC 61850 (GOOSE) or by wire 1 BB CB 2 Cable 3 Cable 3 schneider-electric.com Easergy P3 Catalog | 59 DM105603 Easergy P3 Advanced Base unit presentation Local HMI Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Comprehensive data for easier and faster operation All the data you require for a local equipment operation can be displayed on demand: � Display the single line diagram and freely assignable analog values � Display of all measurements � Display of operation and alarm messages � Display and setting of all parameters � Password entry to protect parameter and protection settings Single line diagram of the power system INFO push-button for viewing additional information, entering the password view, and adjusting the LCD contrast F1 Programmable function push-button PM106371 Ergonomic data presentation � Keypad keys identified by pictograms for intuitive navigation � Graphical 128x128 LCD screen displays any character or symbol � Excellent display quality under all lighting conditions � Control buttons (0/1) to operate the circuit breaker and/or others controlled object � 14 freely programmable LEDs with 3 different colors (red, yellow, and green) to identify easily the message shown � Labels are printed on a transparent film allowing customisation of the relay � 2 programmable function keys (F1 / F2) LED indicators F2 Programmable function push-button ENTER push-button for activating or OK confirming a function UP navigation push-button for moving up in the menu or increasing a numerical value DOWN navigation push-button for moving down in the menu or decreasing a numerical value LEFT navigation push-button for moving backwards in a parallel menu or selecting a digit in a numerical value RIGHT navigation push-button for moving forwards in a parallel menu or selecting a digit in a numerical value O Circuit Breaker OFF push-button Circuit Breaker ON push-button 128 x 128 LCD Object control buttons Navigation push-buttons Local port HOME/CANCEL push-button for returning to the previous menu. To return to the first menu item in the main menu, press the button for at least three seconds Working language All the texts and messages displayed on the Easergy P3 Advanced are available in two languages at the same time. 60 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Base unit presentation Rear panel Rear panel example Slot 1 2 3 4 5 6 8 PM106504 Easergy P3F30, P3M30 and P3G30 9 Slot 1 2 3 4 & 5 6 8 PM106503 Easergy P3M32, P3T32 and P3G32 9 Slot 1 2 3 4 & 5 6 8 PM106342 Easergy P3L30 9 Slots description for P3x30 models Slot 1 - Power supply and output contacts Slot 2 - I/O card 1 Slot 3 - I/O card 2 Slot 4 - I/O card 3 Slot 5 - I/O card 4 Slot 6 - Option card 1 Slot 8 - Analog measurement card 1 Slot 9 - Communication interface Slots description for P3x32 models Slot 1 - Power supply and output contacts Slot 2 - I/O card 1 Slot 3 - I/O card 2 Slot 4/5 - Analog measurement card 2 Slot 6 - Option card 1 Slot 8 - Analog measurement card 1 Slot 9 - Communication interface Slots description for P3L30 models Slot 1 - Power supply and output contacts Slot 2 - I/O card 1 Slot 3 - I/O card 2 Slot 4 - I/O card 3 Slot 5 - I/O card 4 Slot 6 - Option card 1- Line differential com. Slot 8 - Analog measurement card 1 Slot 9 - Communication interface schneider-electric.com Easergy P3 Catalog | 61 Easergy P3 Advanced Description of the optional boards C = 5 x DO heavy duty, A1, SF D = 5 x DO heavy duty, A1, SF A = None G = 6DI+4DO (6 x DI, 4 x DO) H = 6DI+4DO (6 x DI, 4 x DO(NC)) I = 10DI (10 x DI) Base unit presentation Rear panel Digital input and output capability The Easergy P3 Advanced has a modular concept in term of digital inputs and outputs. Number of Input Output 6 11 12 15 18 19 24 23 22 16 32 16 28 19 16 11 26 11 36 11 Slot 1 C/D C/D C/D C/D C/D C/D C/D C/D C/D C/D Type of I/O card � P3X30 Slot 2 Slot 3 Slot 4 G None None G G or H None G G or H G or H G G or H G or H G G or H I G G or H I G G or H G or H G I None G I I G I I Slot 5 None None None G or H None I I None None I PM106504 62 | Easergy P3 Catalog P3x30 units Number of Input Output 6 11 12 15 16 11 Slot 1 C/D C/D C/D Type of I/O card � P3X32 Slot 2 Slot 3 Slot 4 G None None G G or H None G I None Slot 5 None None None PM106503 The slots 4 and 5 are used to receive the analog current input when Easergy P3 is used with differential overcurrent (ANSI 87). P3x32 units schneider-electric.com Easergy P3 Advanced Base unit presentation Remote HMI This mounting technique allows for a lighter door because the relay's frame is installed in the back of the secondary compartment. Communication, DI, and DO cabling is easier, too, as the door movement does not need to be considered. In this case, only the communication between IED base and display has to be wired. DM105604 Easergy schneider-electric.com Easergy P3 Catalog | 63 Easergy P3 Advanced Conventional HMI DM105605 Base unit dimensions Dimensions mm in Easergy 264 10.37 177 6.97 208 8.18 183 7.20 150 5.91 Remote HMI DM105606 199 7.83 180 7.09 247 9.72 180 7.09 199 7.81 150 5.91 Weight (maximum) Easergy P3 Advanced 4.2 Kg (9.272 Ib) or higher (depends of options) Degree of protection (IEC 60529) IP54 Front panel / IP20 Rear side 64 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Base unit dimensions Cut-out and mounting Cut-out accuracy must be complied with to ensure good withstand. Mounting In case the depth dimension behind the compartment door is limited, the IED can be equipped with a frame (REL52832) around the collar. This arrangement reduces the depth inside the compartment by 45 mm (1.77 in). DM105607 Projection mounting with the raising frame REL52832 225 8.86 Panel mounting EaEsaesregrygy 152 5.98 Easergy 1.0-60 Raising frame REL52832 269 10.59 224 8.82 45 1.77 Raising frame REL52832 152 5.98 177 7.0 153 6.02 183 7.20 223.33 9.17 253.40 9.97 Mounting frame 24.60 0.97 Wall mounting with remote HMI DM105608 210 8.27 �5 0.2 mm 100 in 3.94 MTo4rxx2T0-20 1.5Nm 18 0.71 11.5 0.45 20 34 0.79 1.34 Easergy T max. 1.2Nm 10.6 lb.in T max. 0.5...0.6Nm 4.4...5.3 lb.in 3 180 7.09 � 7 0.28 180 7.09 min. 2.5mm2 � 5-8mm Nut M5 1.5 Nm, 13.3 Ib in schneider-electric.com Easergy P3 Catalog | 65 Easergy P3 Advanced Base unit characteristics Technical characteristics Analog inputs Rated phase current Phase Current Input (I) Slot 8 1 A CT 5 A CT Residual Current Input (I0) Slot 8 - 5 A CT Configurable for CT secondaries 0.1 to 10A Residual Current Input (I0') Slot 8 - 1 A CT Configurable for CT secondaries 0.1 to 10.0A Residual Current Input (I0') Slot 8 - 0.2 A CSH sensor Configurable for CT secondaries 0.1 to 10.0A Phase Current Input - (I') Slot 4 (Only for device with differential overcurrent) 1A CT 5A CT Residual Current Input (I0'') Slot 4 (Only for device with differential overcurrent) 1A CT 5A CT Voltage Input Configurable for VT secondaries 50 to 120 V Measuring range 0.02 � 50 A 0.05 � 250 A 0.015 � 50 A 0.003 � 10 A 0.0006 � 2 A 0.02 � 50 A 0.05 � 250 A 0.02 � 50 A 0.05 � 250 A 0.5 � 190 V (100V / 110 V) Input Impedance 0.02 Ohm 0.003 Ohm 0.003 Ohm 0.02 Ohm 0.02 Ohm 0.02 Ohm 0.003 Ohm 0.02 Ohm 0.003 Ohm n.a. Consumption 0.02 VA 0.075 VA Rated thermal withstand 4 A 20 A 0.075 VA 20 A 0.02 VA 4 A 0.02 VA 0.02 VA 0.075 VA 0.02 VA 0.075 VA < 0.5 VA 0.8 A 4 A 20 A 4 A 20 A 250 V (Continuously) 1-second overload 100 A 500 A 500 A 100 A 20 A 100 A 500 A 100 A 500 A n.a. 10-second overload 20 A 100 A 100 A 20 A 4 A 20 A 100 A 20 A 100 A 600 V Analog temperature input / Analog output Type of temperature sensor Maximum distance between sensor and module Analog Output Minimum current Maximum current Pt100 up to 2,000 m(1) Ni100 Ni120 up to 2,000 m (1) up to 2,000 m (1) 0 mA 20 mA Cu10 up to 2,000 m (1) Operating temperature: Power supply Digital Input Nominal operation voltage Typical switching threshold Input limit voltage Frequency Typical consumption Voltage withstand Digital Output Type of contact Rated Voltage Continuous current Breaking AC capacity DC (L/R=40ms) Making capacity Minimum making capacity Typical operation time Contact material REL52811 / REL52812 REL52813 REL52814 DI1 to DI16 At state 1 At state 0 at 48 V dc at 110 V dc at 220 V dc < 0.5 s < 3.0 s 0�C (32�F) to +55�C (131�F) 24 to 230 Vac/dc, 50/60 Hz 24 Vdc 48 to 230 Vac/dc, 50/60 Hz 24 to 230 Vac/dc 12 Vdc 19.2 Vdc < 10.0 Vdc 45 to 65 Hz 110 to 230 Vac/dc 75 Vdc 88 Vdc < 60 Vdc 45 to 65 Hz <4 mA (typical approx. 3 mA) 255 V ac/dc Control and Trip contact, Tx 250 Vac/dc 5 A 2.000 VA 1.15 A 0.5 A 0.25 A 30 A 15 A 100 mA @ 24 Vac/dc <8 ms AgNi 90/10 Signal contact, A1 250 Vac/dc 5 A 2.000 VA 1 A 0.3 A 0.15 A 30 A 15 A 100 mA @ 24 Vac/dc - AgNi 0.15 gold plated 220 to 230 Vac/dc 155 Vdc 176 Vdc < 140 Vdc 45 to 65 Hz Signal Contact, SF 250 Vac/dc 5 A 2.000 VA 1 A 0.3 A 0.15 A - 100 mA @ 24 Vac/dc - AgNi 0.15 gold plated Power supply Nominal Voltage Range Inrush current (DC) Power consumption Acceptable momentary outages (1) 78,740 in 110-240 V ac/dc 24-48 Vdc -20% / +10% (88 to 264 Vac/dc) -20% / +20% (19.2 to 57.6 Vdc) 25 A with time constant of 1000 �s 25 A with time constant of 750 �s 15 A with time constant of 500 �s Power consumption increases when more I/O or optional I/O or communication cards are used Max. 50 W <50 ms (110 Vdc) 66 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Base unit characteristics Environmental characteristics Emission Conducted Emitted Immunity 1 Mhz damped oscillatory wave Static discharge (ESD) Emitted HF field Fast transients (EFT) Surge Conducted HF field Power-frequency magnetic field Pulse magnetic field ac and dc voltage dips ac and dc voltage interruptions Voltage alternative component In operation Vibrations Shocks Seismic De-energized Vibrations Shocks Bump Standard and test class/level IEC/EN 60255-26 (ed3) EN 55022, Class A / CISPR 22 EN 55011, Class A / CISPR 11 IEC/EN 60255-26 (ed3) IEC/EN 61000-4-18 IEC/EN 61000-4-2 Level 4 IEC/EN 61000-4-3 Level 3 IEC/EN 61000-4-4 Level 4 IEC/EN 61000-4-5 Level 4 IEC/EN 61000-4-6 Level 3 IEC/EN 61000-4-8 IEC/EN 61000-4-9 Level 5 IEC/EN 61000-4-29, IEC/EN 61000-4-11 IEC/EN 61000-4-29, IEC/EN 61000-4-11 IEC/EN 61000-4-17 Disturbance tests Test value 0.15 � 30 MHz 30 � 1000 MHz �2.5kVp CM �2.5kVp DM �8 kV contact �15 kV air 80 - 2700 MHz, 10 V/m �4 kV, 5/50 ns, 5 kHz �4 kV, 1.2/50 �s, CM �2 kV, 1.2/50 �s, DM 0.15 - 80 MHz, 10 Vrms 300A/m (continuous) 1000 A/m 1 � 3 s 1000A/m, 1.2/50 �s 0% of rated voltage � ac: 0.5 cycle � dc: 10 ms 40% of rated voltage � ac: 10 cycles � dc: 200 ms 70% of rated voltage � ac: 25 cycles � dc: 500 ms 100% interruption � ac: 250 cycles � dc: 5 s 15% of operating voltage (dc) / 10 min Standard and test class/level IEC 60255-21-1, Class II / IEC 60068-2-6, Fc IEC 60255-21-2, Class II / IEC 60068-2-27, Ea IEC 60255-21-3 Method A, Class II IEC 60255-21-1, Class II / IEC 60068-2-6, Fc IEC 60255-21-2, Class II / IEC 60068-2-27, Ea IEC 60255-21-2, Class II / IEC 60068-2-27, Ea Mechanical robustness Test value 1 Gn, 10 Hz � 150 Hz 10 Gn / 11 ms 2G horizontal / 1G vertical , 1�35 Hz 2 Gn, 10 Hz � 150 Hz 30 Gn / 11 ms 20 Gn / 16 ms schneider-electric.com Easergy P3 Catalog | 67 Easergy P3 Advanced Base unit characteristics Environmental characteristics In operation Impulse voltage withstand Dielectric test Insulation resistance Protective bonding resistance Clearance and creepage distance Power supply burden In operation Dry heat Cold Damp heat, cyclic Damp heat, static Change of temperature In storage Dry heat Cold Standard and test class/level Electrical safety Test value IEC/EN 60255-27 IEC/EN 60255-27 IEC/EN 60255-27 IEC/EN 60255-27 Design criteria for distances as per IEC 60255-27 Annex C (pollution degree 2, overvoltage category 3) IEC 60255-1 5 kV, 1.2/50 �s, 0.5 J 1 kV, 1.2/50 �s, 0.5 J Communication 2 kV, 50 Hz 0.5 kV, 50 Hz Communication Standard and test class/level EN / IEC 60068-2-2, Bd EN / IEC 60068-2-1, Ad EN / IEC 60068-2-30, Db EN / IEC 60068-2-78, Cab IEC / EN 60068-2-14, Nb EN / IEC 60068-2-2, Bb EN / IEC 60068-2-1, Ab Environmental tests Test value 70�C (158�F) -40�C (-40�F) From 25�C (77�F) to 55�C (131�F) From 93% RH to 98% RH Testing duration: 6 days 40�C (104�F) 93% RH Testing duration: 10 days Lower temp -40�C (-40�F) Upper temp 70�C (158�F) 5 cycles 70�C (158�F) -40�C (-40�F) Environmental conditions Ambient temperature, in-service Ambient temperature, storage Relative air humidity Maximum operating altitude -40�C � 60�C (-40�F � 140�F) (1) -40�C � 70�C (-40�F � 158�F) < 95%, no condensation allowed 2000 m (6561.68 ft) (1) with 1 x raising frame -> maximum ambient temperature 55�C (+131�F) with 2 x raising frame -> maximum ambient temperature 50�C (+122�F) 68 | Easergy P3 Catalog schneider-electric.com PM106362 Easergy P3 Advanced Communication Communication protocols Easergy P3 Advanced can be connected to networks, providing access to the following type of data: � Events � Status information � Measurements � Control commands � Clock synchronizing � Settings (SPA-bus and embedded SPA-bus only) Easergy SmartApp. Main Protocols Easergy P3 Advanced can be connected directly to serial and/or Ethernet protocols with two different protocols at the same time, selected by eSetup Easergy Pro software. Communication protocols: Communication ports: Serial protocols - RS232 / RS485 / serial Fiber Optic (*) port Modbus RTU DNP3.0 IEC 60870-5-101 IEC 60870-5-103 DeviceNet (*) ProfibusDP (*) SPA-Bus (*) Ethernet protocols RJ45 / LC port IEC61850 ed1 & ed2 Modbus TCP IEC60870-5-101 DNP3.0 Ethernet IP Comm. interface - Slot 9 Redundancy LC LC � RSTP � PRP Two protocols at the same time WebServer Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Comm. interface - Slot 9 LC RS232 + IRIG-B Two protocols at the same time WebServer Comm. interface - Slot 9 Redundancy � RSTP � PRP Two protocols at the same time WebServer Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Protocols � IEC 61850 � Modbus � DNP3.0 � IEC-101 � Ethernet/IP Protocols � Modbus � DNP3.0 � IEC-103 � SPAbus Comm. interface - Slot 9 RS232 + IRIG-B Two protocols at the same time WebServer Comm. interface - Slot 9 RS232 *Need external accessories to connect. Redundancy protocols (RSTP or PRP) When the devices are connecting in Ethernet link and demand for higher availability, Easergy P3 Advanced can use Rapid Spanning Tree Protocol (RSTP) or Parallel Redundancy Protocol (PRP) to recover from a network failure. Easergy P3 web-HMI Easergy P3 web-HMI A webserver is available in all Easergy P3 Advanced to get information from the device to monitoring all data, send command and change protection setting. PM106576 schneider-electric.com Easergy P3 Catalog | 69 Easergy P3 Advanced Programmable stages Programmable protection function Personalize your protection function Easergy P3 Standard enables you to create or personalize the protection function when you need to achieve specific levels of protection. There are now eight stages available to use with various applications. Each stage can monitor any analog (measured or calculated) signal and issue start and trip signals. Programmable stages extend the protection functionality of the manager series to a new level. The Programmable stage has the possibility of comparing two freely selectable signals between each other. Using this feature you can create a comparison function using the relay's own measured or calculated signals. One or both of the signals can be connected to the comparison function over GOOSE. For example, if four stages of frequency are not enough, it is possible to reach a maximum of 12 using programmable stages. Other examples include using the stages to issue an alarm when there are too many harmonics (THD) or indicating reverse power condition by GOOSE. EM100170 70 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Circuit breaker control With Easergy P3 Advanced, you get intuitive functionality to protect your electrical network system. Main CB functions are: � Trip circuit supervision (ANSI 74) � CT/VT supervision (ANSI 60/60FL) � Latching (ANSI 86) � CB close/open order � Number of operations � Circuit breaker operating time � Charging time � Cumulative breaking current � Personalized functions Maximize circuit breaker control Easergy P3 Advanced is the simplest protection relay with mimic diagram with control buttons (open and close), two personalized function keys and 14 configurable tricolor LEDs. You can manage the control without external or additional components. Example of implementation The schematic is structured for typical use in MV switchgear, 100% adapted for your use case. You can change the internal logic to adapt the Easergy P3 to meet your needs. If a problem occurs, clear and complete information allows you to make the right decisions immediately. MV network CT This electrical schematic can facilitate the IEC 61850 implementation because all the logics are done by the protection unit that will make the decisions and, if necessary, send GOOSE messages to other units. DM105592 HMI interface I 0 Control buttons Function key F1 ON LED A LED C LED E LED G LED I LED K LED M LED F1 Mimic Diagram I1: 0.0A I2: 0.0A I3: 0.0A P : 0.0W V : 0.0V Service LED B LED D LED F LED H LED J LED L LED N LED F2 USB Local Port F2 Inputs AND TIMER Latching contact ANSI 86 Trip control Order contact OR COUNTER Trip Circuit Supervision XOR Output Nominal voltage Alarm contact for Trip circuit failure T2 Close contact Order contact T3 0 1 Open/Close Mechanical command A1 T1 Digital Input 2 Digital Input 1 Trip circuit supervision Trip circuit supervision Trip circuit failure alarm DI 2 DI 1 52a CLOSE COIL OPEN COIL 52b Circuit Breaker schneider-electric.com Easergy P3 Catalog | 71 DM105651 Easergy P3 Advanced Power quality measurements Power quality The power quality of electrical networks has become increasingly important in modern society. Sophisticated loads, such as computers and automation systems, require an uninterrupted supply of "clean" electricity. Easergy P3 Advanced provides integrated power quality measuring and analysis functions, which help to reduce variations in the quality of the distributed power. The terminal supervises the harmonics of phase currents and voltages from the 2nd to the 15th order and the THD (total harmonic distortion).. One of the most important power quality functions is the monitoring of voltage sags and swells. Easergy P3 Advanced provides separate monitoring logs for sags and swells. The fault log comprises four registers for voltage sags and another four for voltage swells. The disturbance recorder functionality can be used for recording measured currents and voltages and for recording status information of digital inputs and outputs, also including the signals of the arc protection system. The time stamped recordings provide indispensable information for the subsequent analysis of a fault situation. Example of harmonics content and voltage sag/swell registration (obtained from an Easergy P3 Advanced protection relay) Many functions in modern society rely heavily on electrical energy, so the quality of the energy supply is gaining increased importance.. Power Quality data in Easergy P3 Advanced THD of IL1, IL2 and IL3 Total harmonic distortion of phase currents H of IL1, Il2 and IL3 Harmonics phase current up to 15th THD of U Total harmonic distortion of phase to phase or phase to ground voltages H of U Harmonic of phase to phase or phase to ground voltage up to 15th Sag and swell Voltage interruptions 72 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Connection diagrams Easergy P3x30 DM105609b DANGER HAZARD OF ELECTRIC SHOCK, ELECTRIC ARC OR BURNS - only qualified personnel should install this equipment. Such work should be performed only after reading this entire set of instructions. - NEVER work alone. - turn off all power supplying this equipment before working on or inside it. Consider all sources of power, including the possibility of backfeeding. - always use a properly rated voltage sensing device to confirm that all power is off. - start by connecting the device to the protective earth and to the functional earth. - screw tight all terminals, even those not in use. Failure to follow these instructions will result in death or serious injury. Arc Flash Sensor Arc Flash Sensor Arc Flash Sensor Arc Flash Sensor 1 0 1 1 2 DI1 V1 2 3 2 USB 3 4 DI2 Local Port V2 4 5 5 V3 6 DI3 6 8/2 7 8 DI4 9 DI5 10 11 DI6 12 13 T13 14 15 T14 16 17 T15 18 19 T16 20 1 2 3 4 5 6 7 8 5A 9 10 11 1 A 12 P3x30 I1 I2 I3 8/1 IIoo Io 3 DI7 DI8 DI9 DI10 DI11 4 1 2 1 DI13 3 2 5 1 4 DI14 3 DI19 2 5 4 3 6 DI15 5 DI20 4 7 6 5 8 7 DI21 9 DI16 8 6 7 10 DI17 11 DI22 10 8 DI12 T17 12 13 DI18 11 12 14 T21 13 T18 15 14 16 T19 17 18 T22 15 16 T23 17 T20 19 18 20 T24 19 20 DI23 10 11 DI24 12 T25 13 14 T26 15 16 T27 17 18 T28 19 7 20 8 V4 8/2 A Arc 1 A Arc 2 A Arc 6 3 A Arc 4 T12 20 19 T11 18 17 T10 16 15 T9 14 T1, T9, T10, T11 and T12: 5 heavy duty trip relay for arc protection 13 T1 12 11 A1 10 9 8 SF 7 6 5 1 2 1 9 Redundant Ethernet Network - RSTP or PRP schneider-electric.com Easergy P3 Catalog | 73 Easergy P3 Advanced Connection diagrams Easergy P3x32 DM105610b DANGER HAZARD OF ELECTRIC SHOCK, ELECTRIC ARC OR BURNS - only qualified personnel should install this equipment. Such work should be performed only after reading this entire set of instructions. - NEVER work alone. - turn off all power supplying this equipment before working on or inside it. Consider all sources of power, including the possibility of backfeeding. - always use a properly rated voltage sensing device to confirm that all power is off. - start by connecting the device to the protective earth and to the functional earth. - screw tight all terminals, even those not in use. Failure to follow these instructions will result in death or serious injury. Arc Flash Sensor Arc Flash Sensor Arc Flash Sensor Arc Flash Sensor 1 0 1 1 2 DI1 V1 2 3 2 USB 3 Local Port V2 4 DI2 4 5 5 DI3 6 7 V3 6 8/2 8 DI4 9 DI5 10 11 DI6 12 13 T13 14 15 T14 16 17 T15 18 19 T16 20 3 1 DI7 2 3 P3x32 DI8 4 5 DI9 6 7 DI10 8 9 DI11 10 11 DI12 12 1 2 I1 3 4 I2 5 6 I3 T17 13 14 T18 15 16 T19 17 7 8 5A 9 10 11 1 A 12 8/1 IIoo1 Io2 18 T20 19 20 7 8 V4 8/2 A Arc 1 A Arc 2 A Arc 6 3 A Arc 4 T12 20 19 T11 18 17 T10 16 15 T9 14 4 1 2 1A 3 I'1 4 5 1A 6 I'2 7 8 1A 9 I'3 10 11 1 A 12 Io3 13 T1 12 11 A1 10 9 8 SF 7 6 5 1 2 1 9 T1, T9, T10, T11 and T12: 5 heavy duty trip relay for arc protection Redundant Ethernet Network - RSTP or PRP 74 | Easergy P3 Catalog schneider-electric.com Easergy P3 Advanced Connection diagrams Easergy P3L30 DM105611b DANGER HAZARD OF ELECTRIC SHOCK, ELECTRIC ARC OR BURNS - only qualified personnel should install this equipment. Such work should be performed only after reading this entire set of instructions. - NEVER work alone. - turn off all power supplying this equipment before working on or inside it. Consider all sources of power, including the possibility of backfeeding. - always use a properly rated voltage sensing device to confirm that all power is off. - start by connecting the device to the protective earth and to the functional earth. - screw tight all terminals, even those not in use. Failure to follow these instructions will result in death or serious injury. 1 0 Line Diff. Network 1 1 2 DI1 V1 2 3 2 USB 3 4 DI2 Local Port V2 4 5 5 DI3 6 7 V3 6 8/2 8 DI4 9 DI5 10 11 DI6 12 13 T13 14 15 T14 16 17 T15 18 19 T16 20 P3L30 1 2 3 4 5 6 7 8 5A 9 10 11 1 A 12 7 I1 I2 I3 8/1 IIoo Io 3 DI7 DI8 DI9 DI10 DI11 4 1 5 2 1 DI13 3 2 1 4 DI14 3 DI19 2 5 4 3 6 DI15 5 DI20 4 7 6 5 8 7 DI21 9 DI16 8 6 7 10 DI17 11 DI22 10 8 DI12 T17 12 13 DI18 11 DI23 12 10 11 14 T21 13 DI24 T18 15 16 14 T22 15 12 T25 13 T19 17 18 16 T23 17 14 T26 15 T20 19 20 18 T24 19 16 T27 17 20 18 T28 19 20 8 V4 8/2 T12 20 19 T11 18 17 T10 16 15 T9 14 T1, T9, T10, T11 and T12: 5 heavy duty trip relay for arc protection 13 T1 12 Diff. Comms. Card RX 6 TX 11 A1 10 9 8 SF 7 6 5 1 2 1 9 Redundant Ethernet Network - RSTP or PRP schneider-electric.com Easergy P3 Catalog | 75 Easergy P3 Advanced PM106371 PM106371 Model selection Selecting product Please, consult the "Ordering" section to choose specific characteristics in the relays for your system: P3F30 Feeder application P3L30 Line application P3M30 Motor application P3G30 Generator application Page 109 Page 110 Page 111 Page 112 P3T32 Transformer Page 113 with differiential application P3M32 Motor Page 114 with differential application P3G32 Generator Page 115 with differrential application Or use our web configuration tool: Go to web configurator 76 | Easergy P3 Catalog schneider-electric.com Notes schneider-electric.com Easergy P3 Catalog | 77 Easergy digital experience 78 | Easergy P3 Catalog schneider-electric.com Easergy digital experience Easergy P3 software 80 Presentation 80 eSetup Easergy Pro 82 eSetup Easergy Pro during engineering 82 eSetup Easergy Pro during commissioning 83 eSetup Easergy Pro during operation 84 Easergy web-HMI 85 Easergy SmartApp 86 schneider-electric.com Easergy P3 Catalog | 79 Easergy digital experience Easergy P3 software Presentation Minimum requirements for running eSetup Easergy Pro: � Windows 7 or higher � 512 MB RAM � 50 MB Disk space eSetup Easergy Pro eSetup Easergy Pro offers full facilities to set up Easergy relays. Intuitive and simple, eSetup Easergy Pro is a user-oriented interface to assist you during the engineering, commissioning and operation of Easergy protection relays. ts streamlined workflow and graphical representations has been designed to smooth your configuration process. The software is available for download on the Schneider Electric website. DM105612 DM105613 DM105614 eSetup Easergy Pro eSetup Easergy Pro eSetup Easergy Pro Use eSetup Easergy Pro in standalone mode during engineering to prepare the configuration. Connect the PC running eSetup Easergy Pro to the USB port of the Easergy protection relay during commissioning to adjust the settings and test the relay. For connection to Easergy P3, use the REL52822 connection cord Connect the PC running eSetup Easergy Pro to the Ethernet network during operation to retrieve data from the relays and update the system. 80 | Easergy P3 Catalog schneider-electric.com DM105615 Engineering Easergy digital experience Easergy P3 software Presentation eSetup Easergy Pro at each step of the digital life Commiss ioning Operation schneider-electric.com Easergy P3 Catalog | 81 Easergy digital experience eSetup Easergy Pro During engineering � Create the configuration of the Easergy P3 relay: select the appropriate options and receive the order code � Set the characteristics of the CTs, VTs, or sensors connected to the relay, and select the protection functions that will be activated and their settings � Build a specific logic, if required, using a graphic editor � Map the digital inputs of the relay and different internal signals to the relevant functions, LEDs, and digital outputs, using a straightforward matrix format. � Draw the single-line diagram that will appear on the front display of the relay for switchgear control and select the measurements that will be displayed. If any, build the interlocking logic using a matrix format � For IEC 61850 protocol, configure the data set and the report control blocks that will be published and select the GOOSE data to which you want to subscribe � Complete the setting of additional functions (disturbance recorder, event logging system, clock synchronization, etc.). EM106160 EM106161 EM106162 82 | Easergy P3 Catalog schneider-electric.com Easergy digital experience eSetup Easergy Pro During commissioning � Connect to the front panel of one single relay or access several relays by connecting to Ethernet � Open the Digital Inputs menu to check the status of inputs. Reverse the polarity or add a filtering delay if necessary � Open the Relays menu and force the status change of the output relays in order to check the wiring. � Open the Phasor Diagram menu to see in real time the phasor of injected currents and voltages and the value � Use virtual injection for testing protection settings and circuit breaker tripping and for checking LEDs and connected outputs � Open the Logic or the Matrix menu if the logic needs to be tested. The active signals appear in a different color and are updated in real time. Changes in the logic or in the matrix can be made and applied to the relay smoothly. EM106163 EM106164 EM106165 schneider-electric.com Easergy P3 Catalog | 83 Easergy digital experience eSetup Easergy Pro During operation � Connect to the front panel of a single relay or gain access to several relays by connecting to Ethernet � During normal operation, get the most of the metering capabilities of the Easergy protection relay: �� Open the different Measurements menus to access the power monitoring and power quality data. �� Open the disturbance recorder menu to get a waveform capture or program the recording of a power trend. � After a trip, use eSetup Easergy Pro to understand the fault: �� Check the fault log of the protection that has tripped the circuit breaker �� Download the disturbance record from the Easergy P3 and display it with a disturbance recorder evaluation tool, eg. Wavewin. EM106166 EM106168 EM106167 84 | Easergy P3 Catalog schneider-electric.com Easergy digital experience Easergy web-HMI Description Enhance operational efficiency � Direct access to protection and communication settings � Control and monitoring of circuit breakers and switches � Mirror HMI function � Direct access to measurements including the graphic phasors � Device diagnosis � MATRIX status � Access to logs and other information Boost operational efficiency with the embedded web-HMI Quickly and conveniently configure, monitor, and operate your Easergy P3 protection relay with our web-HMI. The web-HMI, accessible online via IP address of the relay, doesn't require you to install specific computer software - simply use your web browser to connect to the device. You only need to enable the web server service during the initial configuration of Easergy P3 with eSetup Easergy Pro. The web-HMI is based on the same page design as eSetup Easergy Pro, making it easy to use! schneider-electric.com Easergy P3 Catalog | 85 Easergy digital experience Easergy SmartApp Description Discover how the Easergy SmartApp can simplify your daily operations Use the Easergy SmartApp to control Easergy P3 to improve safety, simplify operations and maintenance, and save valuable operational time(1). Safety The Easergy SmartApp improves safety by allowing the operator to stay away from the circuit-breaker during operations. Simplicity The Easergy SmartApp provides easy access to device status, control, and monitoring of the circuit breaker, measurements, settings, events and other functions, through the mirror HMI or a simplified view. � Mirror HMI: Duplicate the device display in the Easergy SmartApp to perform actions more easily and safely. � Simplified view: The Easergy SmartApp gives you an organized view of all the device's functionalities for simpler access to the data. You benefit from a clearer overview of the switchgear's health, faster issue resolution, and safer operations. Easergy SmartApp screens example Free download on: 86 | Easergy P3 Catalog (1) Wi-Fi is not embedded in Easergy P3, a separate Wi-Fi router connected to an Ethernet port of the device is required. schneider-electric.com Notes schneider-electric.com Easergy P3 Catalog | 87 Additional modules and accessories 88 | Easergy P3 Catalog schneider-electric.com Additional modules and accessories Connection cables 90 Communication modules 92 Temperature and analogue input and output modules 94 Arc flash sensors 96 schneider-electric.com Easergy P3 Catalog | 89 PM106970 PM106980 PM106969 Additional modules and accessories Connection cables Description Cables for Easergy P3 Standard The cables can be used for connecting external option modules to the Easergy P3 Standard. The device is equipped with I/O communication model E or F, where RS232 interface is available. REL52825 A remote port is available when a REL52825 cable is used. The cable contains a connector for the RS-232 interface of the Easergy P3 Standard and a D9connector for the external option module. Length 2.5 m (78.74 in) REL52827 The cable contains a connector for the RS-232 interface of the Easergy P3 Standard and a D9-connector for the REL52815 Profibus interface module. An extension port is available for the REL52827 in Easergy P3 Standard. Length 3.0 m (118.11 in) REL52826 Remote and extension ports are available, in addition to IRIG-B clock synchronization, when the REL52826 cable is used. The REL52826 cable contains a connector for the RS-232 interface of the Easergy P3 Standard and a 3-piece D9-connector for the external option module and IRIG-B. Length 2.5 m (78.74 in) 90 | Easergy P3 Catalog schneider-electric.com PM106978 PM106979 PM106978 Additional modules and accessories Connection cables Description Cables for Easergy P3 Advanced The cables can be used for connecting external option modules to the Easergy P3 Advanced.The device is equipped with I/O communication model B, C or D, where RS232 interface is available. REL52823 Remote and extension ports are available in addition to IRIG-B clock synchronization when the REL52823 cable is used. The REL52823 cable contains a connector for the RS232 interface of Easergy P3 Advanced and 3-piece D9-connector for the external option module and IRIG-B. Length 3.0 m (118.11 in) REL52824 The cable contains a connector for the RS232 interface of Easergy P3 Advanced and D9-connector for the REL52815 Profibus interface module. An extension port is available for the REL52824 in Easergy P3 Advanced. Length 3.0 m (118.11 in) Cables for all Easergy P3 models Front face USB Cable - REL52822 The Easergy P3 protection relays have a USB-connector in the front panel. Use eSetup Easergy Pro setting software with USB cable to set the device. Length 3.0 m (118.11 in) schneider-electric.com Easergy P3 Catalog | 91 PM106586 PM106581 Additional modules and accessories Communication modules Network interface modules RS232 to RS485 network � REL52820 The external RS485 interface REL52820 is used to connect Easergy P3 devices to the RS485 network. With the RS485 serial interface module it is possible to have following serial protocols in use. Characteristics Distance (maximum) 200 m (7,874.02 in) Devices (maximum) 32 Type of fiber optic connector PIN (3) Type of RS232 connector 9-pin DSUB connector RS485 type 2-wire Serial protocols Modbus, DNP3.0, IEC870-5-103 and SpaBus Power supply From RS232 port or external � 12Vdc To connect the interface with: Easergy P3 Standard devices, use REL52825 cable Easergy P3 Advanced devices, use REL52823 cable if needed RS232 to fiber optic network � REL52816 to REL52819 An external fiber optic interface is used to connect Easergy P3 devices to a fiber optic loop or a fiber optic star network. The options include two different types of serial fiber optic modules. Characteristics REL52819 REL52816 Distance (maximum) 30 m (1,181 in) 1,000 m (39,370 in) Type of fiber optic Plastic-Plastic Glass-Glass FO diameter 1 mm 62.5/125 uM Devices (maximum) 32 32 Type of fiber optic connector HP Versalink Snap-in ST connector Interface 9-pin DSUB connector Serial protocols Modbus, DNP3.0, IEC870-5-103 and SpaBus Power supply From RS232 port or external � 12 Vdc To connect the interface with: Easergy P3 Standard devices, use REL52825 cable Easergy P3 Advanced devices, use REL52823 cable if needed 92 | Easergy P3 Catalog schneider-electric.com PM106585 PM106580 Additional modules and accessories Communication modules Network interface modules DeviceNet network interface � REL52821 External RS485 DeviceNet interface REL52821 is used to connect Easergy P3 devices to RS485 network using DeviceNet protocol. Characteristics Distance (maximum) 200 m (7,874.02 in) Devices (maximum) 32 Type of output connector PIN Type of RS232 connector 9-pin DSUB connector Serial protocols DeviceNet Power supply Need power feed from both RS232 port and external 24 Vdc To connect the interface with: Easergy P3 Standard devices, use REL52825 cable Easergy P3 Advanced devices, no additional cable required Profibus network interface � REL52815 External Profibus interface REL52815 is used to connect Easergy P3 devices to the Profibus network. Characteristics Interface 9-pin DSUB connector (Female) Transfer method RS485, Half-duplex Transfer cable Twisted pair (1 pair and shield) Electrical isolation 500 Vdc Serial protocols Profibus DP Baud rate 9.6 kBaud to 12 Mbaud Power supply Easergy P3 Standard: Easergy P3 Advanced: External � 12Vdc From RS232 port or external � 12Vdc To connect the interface with: Easergy P3 Standard devices, use REL52827 cable Easergy P3 Advanced devices, use REL52824 cable schneider-electric.com Easergy P3 Catalog | 93 Additional modules and accessories Temperature and analog input/output modules For Easergy P3 The temperature module is supplied ready for operation with: � Easergy P3U20, P3U30 with RS485 communication port direct � Easergy P3U20, P3U30, and P3X3x with RS232 communication port by REL52820 external RS485 interface � Easergy P3U20, P3U30, and P3X3x with RS232 communication port by REL52816 to REL52819 external fiber optic interface Function The temperature modules can be used to connect temperature sensors from the field to the Easergy P3 devices using a communication port RS485 by twist-pair or fiber optic. The temperature measurement is utilized by the following protection functions in transformer and motor application: � Thermal overload � Temperature monitoring � Customized logic or custom protection function The modules REL52813 and REL52814 have analog input and output to use in the special controls functions. DM105626 REL52811 Fiber Rx Tx RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 94 | Easergy P3 Catalog REL52812 RS485 Rx Tx RTD CH01 RTD CH02 RTD CH03 RTD CH04 RTD CH05 RTD CH06 RTD CH07 RTD CH08 RTD CH09 RTD CH10 RTD CH11 RTD CH12 REL52813 REL52814 RS485 Rx Tx Fiber Rx Tx PTC RTD CH01 RTD CH02 mA In1 RTD CH03 mA In2 RTD CH04 mA In3 RTD CH05 mA In4 RTD CH06 RTD CH07 mA OUT1 RTD CH08 mA OUT2 RTD CH09 mA OUT3 RTD CH10 mA OUT4 RTD CH11 RTD CH12 schneider-electric.com Additional modules and accessories Temperature and analog input/output modules Temperature input modules � REL52811 / REL52812 / REL52813 / REL52814 Characteristics Interface Distance (maximum) Quantity of Temperature sensors Supported RTD types Measuring range Measuring resolution Measuring accuracy Sensor distance Power Supply Operating Temperature Mounting Type Degree of protection REL52811 REL52812 REL52813 REL52814 Glass fiber (ST) RS485 Twisted Pair Glass fiber (ST) OR RS485,TP 2,000 m (78,740 in) 1,200 m* (47,244 in) 2 000 m / 1 200 m* 12 channels, 3-wire 12 channels, 3-wire and 1 PTC channel 2-wire Pt100, Ni00, Ni120 and Cu10 1 - 400 0.10 �0.3 50 (corresponds to 2 000 m at 0.75 ) 24 - 230 Vac/dc 50/60 Hz 24 Vdc 48 - 230 Vac/dc 50/60 Hz 0�C (32�F) to 55�C (131�F) DIN Rail IP20 * The value may decrease according to the conditions of use Analog Input / Output modules � REL52811 / REL52812 / REL52813 / REL52814 Characteristics Analog Input (mA) Input Range Input accuracy Input resolution REL52811 0 - REL52812 0 - REL52813 4 0-25 mA �1% 6uA (12-bits) REL52814 4 0-25 mA �1% 6uA (12-bits) Input impedance Analog Output (mA) Output range Output accuracy Output resolution Galvanic isolation Max. Load/output PTC Input Measuring accuracy - - 100 100 0 0 4 4 - - 0-25 mA 0-25 mA - - �1% �1% - - 6uA (12-bits) 6uA (12-bits) - - 1000 V 1000 V - - 750 750 - - 1 1 - - �10% (<10 k ) �10% (<10 k ) * The value may decrease according to the conditions of use schneider-electric.com Easergy P3 Catalog | 95 Additional modules and accessories Arc flash sensors For Easergy P3 Advanced only Arc flash sensors Sensors description The sensor is used by an arc flash protection device (Easergy P3 Advanced) or system to detect the light coming from the arc flash incident. The Easergy P3 Advanced arc sensor is activated by strong light. The sensor transforms the light information into the current signal, which is used by the protection device to indicate arc flash. REL52801 REL52802 REL52803 REL52804 REL52805 REL52806 REL52807 REL52808 REL52809 REL52810 Characteristics Material Plastic Type Standard Weight 1,000 g 1,300 g 1,300 g 300 g 400 g 400 g 1,000 g 2.20 lb 2.87 lb 2.87 lb 0.66 lb 0.88 lb 0.88 lb 2.20 lb Cable length (m) 6 20 20 6 6 6 20 Shielded cable - - - - - Halogen free - - - - - Environment Pollution Degree 2 Operation temperature -25�C (-13�F) to +70�C (+158�F) Light spectrum sensitive area 400 � 1100 nm Detection time 1 ms Light sensitivity 8 000 � 10 000 lux Loop supervision Yes To connect the interface in the Easergy P3 Standard devices, use REL52883 cable. Pipe 1,300 g 300 g 2.87 lb 0.66 lb 20 6 - - - 400 g 0.88 lb 6 - DM105632 REL52801 - 52806 dimensions mm 22.2 in 0.83 14 0.55 20 0.79 10 0.39 46.4 1.83 Sensitivity area REL52807 - 52810 dimensions mm 11 in 0.43 62 2.44 25 0.98 8 0.31 4.2 0.17 DM105635 DM105636 96 | Easergy P3 Catalog Arc Flash sensor: Pipe type schneider-electric.com Additional modules and accessories Arc flash sensors For Easergy P3 Advanced only Direct mounting on switchgear Setting the light sensor in the switchgear requires either special supports type REL52828 (mounting plate for sensor Z-shape) or REL52829 (mounting plate for sensor L-shape), or it can be mounted in customer drilled holes. Mounting options REL52829 dimensions mm in 10 0.39 PM106972 DM105637 PM106971 15 59 15 0.59 2.32 0.59 DM105633 Before 3 0.12 30 1.18 30 1.18 Mounting plate for sensor L-shape DM105634 DM105637 After REL52828 dimensions mm 50 in 15 1.97 0.59 51 25 2.0 0.98 59 2.32 42 1.65 7 0.28 2.5 0.1 10 0.39 15 50 0.59 1.97 Mounting plate for sensor Z-shape schneider-electric.com Easergy P3 Catalog | 97 Schneider Electric Service 98 | Easergy P3 Catalog schneider-electric.com Schneider Electric Service Providing peace of mind throughout your installation life cycle 100 Endorsing the most eco-friendly products in the industry: Green PremiumTM 101 schneider-electric.com Easergy P3 Catalog | 99 DM408843 Schneider Electric Service Providing peace of mind throughout your installation life cycle How can you cut costs and improve performance at the same time? When it comes to your electrical distribution infrastructure, the answer is straight-forward - get professional expertise. Plan We help you plan the full design and execution of your solution, looking at securing your process and optimizing your time: � Technical feasibility studies: Accompany you to design a solution in your given environment � Preliminary design: Accelerate turnround time to come to a final solution design Life Life cycle Cycle services Services Plan What are my options? Install How do I install and commission? Operate How do I operate and maintain? Optimize How do I optimize? Install We help you install efficient, reliable, and safe solutions based on your plans: � Project management: Designed to help you complete your projects on time and within budget � Commissioning: Ensure your actual performance versus design, through on-site testing and commissioning, tools, and procedures Operate We help you maximize your installation uptime and control your capital expenditures through our service offering: � Asset operation solutions � Advantage service plans � On-site maintenance services � Spare parts management � Technical training Renew How do I renew my solution? When it comes to your electrical distribution installation, we can help you: � Increase productivity, reliability, and safety � Mitigate risk and limit downtime � Keep equipment up to date and extend its lifespan � Cut costs and increase savings � Improve your return on investment CONTACT US! www.schneider-electric.com/ electricaldistributionservices Optimize We provide recommendations to improve your safety, availability, reliability, and quality: � MP4 electrical assessment: Define your improvement and risk management program Renew We extend the life of your system while providing upgrades and offers to take full responsibility for the end-of-life processing of old electrical equipment: � Retrofit: Keep up to date and improve the performance of your electrical installations (LV, MV, Protection Relays, etc.) � MV product end of life: Recycle and recover your outdated equipment with end-of-life services 100 | Easergy P3 Catalog schneider-electric.com Schneider Electric Service Endorsing the most eco-friendly products in the industry Green Premium is the only label that allows you to effectively develop and promote an environmental policy whilst preserving your business efficiency. This ecolabel guarantees compliance with the most up-to-date environmental regulations, but it does more than this. Our Green Premium ecolabel is committed to offering transparency by disclosing extensive and reliable information related to the environmental impact of its products: RoHS Our products are subject to RoHS requirements at a worldwide level, even for the many products that are not required to comply with the terms of the regulation. Compliance certificates are available for products that fulfill the criteria of this European initiative, which aims to eliminate hazardous substances. REACh We apply the strict REACh regulation to our products at a worldwide level and disclose extensive information concerning the presence of SVHC (Substances of Very High Concern) in all of these products. PEP: Product Environmental Profile Asumption data, for each of the lifecycle phases on all of our products, in compliance with the ISO 14025 PEP ecopassport program. PEP is especially useful for monitoring, controlling, saving energy, and/or reducing carbon emissions. EoLI: End of Life Instructions Available at the click of a button, these instructions provide: � Recyclability rates for our products. � Guidance for mitigating personnel hazards during the dismantling of your products and before recycling operations. � P arts identification for recycling or for selective treatment, to mitigate environmental hazards/incompatibility with standard recycling processes. Discover what we mean by green .... Check your products! 75% Over of our manufactured products have been awarded the Green Premium ecolabel schneider-electric.com Easergy P3 Catalog | 101 Ordering 102 | Easergy P3 Catalog schneider-electric.com Ordering Fast Ordering Code Easergy P3 Standard Easergy P3U10 configuration Easergy P3U20 configuration Easergy P3U30 configuration Easergy P3 Advanced Easergy P3F30 configuration Easergy P3L30 configuration Easergy P3M30 configuration Easergy P3M32 configuration Easergy P3T32 configuration Easergy P3G30 configuration Easergy P3G32 configuration Accessories 104 107 108 108 109 110 110 111 112 113 114 115 116 117 schneider-electric.com Easergy P3 Catalog | 103 Ordering Fast ordering code Easergy P3 Standard Easergy P3 Standard Commercial Ref. Product Reference REL52001 REL52002 REL52003 REL52004 REL52005 REL52006 REL52007 REL52008 REL52009 REL52010 REL52011 REL52012 REL52013 REL52014 REL52015 REL52016 REL52017 REL52018 REL52019 REL52020 REL52021 REL52022 REL52023 REL52024 REL52025 REL52026 REL52027 REL52028 REL52029 REL52030 REL52031 REL52032 REL52033 P3U30-5AAA3BCAA P3U30-5AAA3BBAA P3U30-5AAA1BCAA P3U30-5AAA2BCAA P3U30-5AAA1BBAA P3U30-5ABA1BBAA P3U30-5AAA1BDAA P3U30-6AAA2BCAA P3U30-5ABA1BCAA P3U30-5AAA2BDAA P3U20-5ABA1ACAA P3U30-5AAA2BBAA P3U20-5AAA1ACAA P3U30-5ABA1BDAA P3U20-6AAA2ACAA P3U30-6AAA2BBAA P3U30-6AAA3BCAA P3U20-5AAA2ACAA P3U30-5AAA1BFAA P3U30-6ABA1BBAA P3U30-6AAA2BDAA P3U30-6AAA1BCAA P3U20-6ABA1ADAA P3U20-5ABA1ADAA P3U30-5BAA2BCAA P3U10-5AAA1AAAA P3U10-6AAA1AAAA P3U10-5AAA2AAAA P3U10-6AAA2AAAA P3U10-5AAA3AAAA P3U10-6AAA3AAAA P3U20-5AAA1ABAA P3U20-5AAA1ADAA Nominal Power Supply Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power B 24 V Power A 48-230 V Power A 48-230 V Power B 24 V Power A 48-230 V Power B 24 V Power A 48-230 V Power A 48-230 V Power B 24 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power B 24 V Power A 48-230 V Power A 48-230 V Power B 24 V Power B 24 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Nominal Digital Input Voltage 220-230 Vac/dc 220-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 110-230 Vac/dc 220-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 110-230 Vac/dc 220-230 Vac/dc 220-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc Voltage Nbr. Digital Input Input/Output 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 1 10 DI / 5 DO 4 16 DI / 8 DO 1 10 DI / 5 DO 4 16 DI / 8 DO 1 10 DI / 5 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 1 10 DI / 5 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 4 16 DI / 8 DO 1 2 DI / 5 DO 1 2 DI / 5 DO 1 2 DI / 5 DO 1 2 DI / 5 DO 1 2 DI / 5 DO 1 2 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO Option Screw connector Screw connector Screw connector Screw connector Screw connector Screw connector Screw connector Ring-lug connector Screw connector Screw connector Screw connector Screw connector Screw connector Screw connector Ring-lug connector Ring-lug connector Ring-lug connector Screw connector Screw connector Ring-lug connector Ring-lug connector Ring-lug connector Ring-lug connector Screw connector Screw connector Screw connector Ring-lug connector Screw connector Ring-lug connector Screw connector Ring-lug connector Screw connector Screw connector Com. Port 2 x RJ45 RS485 2 x RJ45 2 x RJ45 RS485 RS485 2 x LC 2 x RJ45 2 x RJ45 2 x LC 2 x RJ45 RS485 2 x RJ45 2 x LC 2 x RJ45 RS485 2 x RJ45 2 x RJ45 LC + RS232 RS485 2 x LC 2 x RJ45 2 x LC 2 x LC 2 x RJ45 none none none none none none RS485 2 x LC 104 | Easergy P3 Catalog schneider-electric.com Ordering Fast ordering code Easergy P3 Standard Easergy P3 Standard Commercial Ref. Product Reference REL52034 REL52035 REL52036 REL52037 REL52038 REL52039 REL52040 REL52041 REL52042 REL52043 REL52044 REL52045 REL52046 REL52047 REL52048 REL52049 REL52050 REL52051 P3U20-6AAA1ABAA P3U20-6AAA1ACAA P3U20-6AAA1ADAA P3U20-5AAA2ABAA P3U20-5AAA2ADAA P3U20-6AAA2ABAA P3U20-6AAA2ADAA P3U20-5AAA3ABAA P3U20-5AAA3ACAA P3U20-5AAA3ADAA P3U20-6AAA3ABAA P3U20-6AAA3ACAA P3U20-6AAA3ADAA P3U30-6AAA1BBAA P3U30-6AAA1BDAA P3U30-5AAA3BDAA P3U30-6AAA3BBAA P3U30-6AAA3BDAA Nominal Power Supply Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Power A 48-230 V Nominal Digital Input Voltage 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 110-230 Vac/dc 110-230 Vac/dc 110-230 Vac/dc 220-230 Vac/dc 220-230 Vac/dc 220-230 Vac/dc 220-230 Vac/dc 220-230 Vac/dc 220-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 220-230 Vac/dc 220-230 Vac/dc 220-230 Vac/dc Voltage Nbr. Digital Input Input/Output 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 1 10 DI / 5 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO 4 16 DI / 8 DO Option Ring-lug connector Ring-lug connector Ring-lug connector Screw connector Screw connector Ring-lug connector Ring-lug connector Screw connector Screw connector Screw connector Ring-lug connector Ring-lug connector Ring-lug connector Ring-lug connector Ring-lug connector Screw connector Ring-lug connector Ring-lug connector Com. Port RS485 2 x RJ45 2 x LC RS485 2 x LC RS485 2 x LC RS485 2 x RJ45 2 x LC RS485 2 x RJ45 2 x LC RS485 2 x LC 2 x LC RS485 2 x LC For more configuration or options, please use our web configurator or see: page 107 for Easergy P3U10 page 108 for Easergy P3U20 page 109 for Easergy P3U30 Go to web configurator schneider-electric.com Easergy P3 Catalog | 105 Ordering Fast ordering code Easergy P3 Advanced Easergy P3 Advanced Commercial Ref. REL52101 REL52102 REL52103 REL52104 REL52105 REL52106 REL52107 REL52108 REL52109 REL52110 REL52111 REL52112 REL52113 REL52114 REL52115 REL52116 REL52117 REL52118 REL52119 REL52120 Product Reference Nominal Power Supply P3F30-CGGGG-AAENA-BAAAA Power C 110-230 V P3F30-CGGGI-AAENA-BBAAA Power C 110-230 V P3F30-CGGGI-DAECA-BBAAA Power C 110-230 V P3F30-CGGIA-AAEBA-BCAAA Power C 110-230 V P3F30-CGGIA-AAECA-BAAAA Power C 110-230 V P3F30-CGGIA-AAENA-BAAAA Power C 110-230 V P3F30-CGGIA-AAEOA-BBAAA Power C 110-230 V P3F30-CGGIA-DAENA-BAAAA Power C 110-230 V P3F30-CGIAA-AAECA-BAAAA Power C 110-230 V P3F30-CGIAA-AAEDA-BBAAA Power C 110-230 V P3F30-CGIAA-DAENA-BAAAA Power C 110-230 V P3F30-CGIIA-AAENA-BAAAA Power C 110-230 V P3F30-DGGGG-AAENA-BAAAA Power D 24-48 V P3F30-DGGGI-AAENA-BAAAA Power D 24-48 V P3F30-DGGIA-AAECA-BAAAA Power D 24-48 V P3F30-DGGIA-AAENA-BAAAA Power D 24-48 V P3F30-DGGIA-DAENA-BAAAA Power D 24-48 V P3F30-DGIAA-AAENA-BAAAA Power D 24-48 V P3F30-DGIAA-DAENA-BAAAA Power D 24-48 V P3F30-DGIIA-AAENA-BAAAA Power D 24-48 V Nominal Digital Input Voltage 24-230 Vac/dc 110-230 Vac/dc 110-230 Vac/dc 220-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 110-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc 24-230 Vac/dc Voltage Nbr. Digital Input Input/Output 4 24 DI / 21 DO 4 28 DI / 17 DO 4 28 DI / 17 DO 4 22 DI / 13 DO 4 22 DI / 13 DO 4 22 DI / 13 DO 4 22 DI / 13 DO 4 22 DI / 13 DO 4 16 DI / 9 DO 4 16 DI / 9 DO 4 16 DI / 9 DO 4 26 DI / 9 DO 4 24 DI / 21 DO 4 28 DI / 17 DO 4 22 DI / 13 DO 4 22 DI / 13 DO 4 22 DI / 13 DO 4 16 DI / 9 DO 4 16 DI / 9 DO 4 26 DI / 9 DO Option Com. Port 4 Arc sensors 4 Arc sensors 4 Arc sensors 4 Arc sensors 4 Arc sensors 4 Arc sensors 4 Arc sensors - 2 x RJ45 2 x RJ45 RS232 + RJ45 RS232 RS232 + RJ45 2 x RJ45 2 x LC 2 x RJ45 RS232 + RJ45 RS232 + LC 2 x RJ45 2 x RJ45 2 x RJ45 2 x RJ45 RS232 + RJ45 2 x RJ45 2 x RJ45 2 x RJ45 2 x RJ45 2 x RJ45 For more configuration or options, please use our web configurator or see: page 110 for Easergy P3F30 page 113 for Easergy P3M32 page 111 for Easergy P3L20 page 114 for Easergy P3T32 page 112 for Easergy P3M30 page 115 for Easergy P3G30 page 116 for Easergy P3G32 Go to web configurator 106 | Easergy P3 Catalog schneider-electric.com Ordering Easergy P3 Standard Easergy P3U10 configuration U10 X1 X1 X2 A X5 A X4 A A A Application U10 Feeder & Motor, 4xI, 1xU. 2DI, 5DO Phase currents & voltage input, X1 5 1 A / 5 A & 1U (100/110 V), pluggable clamp connector 6 1 A / 5 A & 1U (100/110 V), pluggable ring lug connector Earth-fault current input A 1A/5A B 0,2 A / 1 A Nominal power supply voltage [V] A Power A 48 - 230 V (range: 40 ... 265 Vac/dc) B Power B 24 V (range: 18 ... 36 Vdc) Future option A None Digital input treshhold voltage (V) 1 24 Vac/dc 2 110 Vac/dc 3 220 Vac/dc Voltage measurements + I/O, X5 A None I/O with comms, X4 A None Product version A Version 2.1 Region A International 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: Easergy P3 U10 Slot numbers X1 X1 A X2 AAAA X5 X4 schneider-electric.com Easergy P3 Catalog | 107 Ordering Easergy P3 Standard Easergy P3U20 configuration U20 X1 X1 X2 A X5 A X4 A A Application U20 Feeder & Motor, 4xI, 1xU. 2DI, 5DO Phase currents & voltage input, X1 5 1 A/ 5 A & 1U (100/110 V), pluggable clamp connector 6 1 A / 5 A & 1U (100/110 V), pluggable ring lug connector Earth-fault current input, X1 A 1A/5A B 0,2 A / 1 A Nominal Supply Voltage [V], X2 A Power A 48 - 230 V (range: 40 ... 265 Vac/dc) B Power B 24 V (range: 18 ... 36 Vdc) Future option A None Digital input treshhold voltage (V) 1 24 Vac/dc 2 110 Vac/dc 3 220 Vac/dc Voltage measurements + I/O, X5 A None I/O with comms, X4 B RS-485 + 8DI C 2 x RJ-45 + 8DI D 2 x LC + 8DI E RJ + 232 + 8DI with IRIG-B F LC + 232 + 8DI with IRIG-B Product version A Version 2.1 Region A International 1. Choose your option 2. Mark your choice in the box below 3. Check your order code:: Easergy P3 U20 Slot numbers X1 X1 A X2 A AA X5 X4 108 | Easergy P3 Catalog schneider-electric.com Ordering Easergy P3 Standard Easergy P3U30 configuration U30 X1 X1 X2 A X5 B X4 A A Application U30 Feeder & Motor, 4xI, 4xU. 2DI, 5DO Phase currents & voltage input, X1 5 1 A/ 5 A & 1U (100/110 V), pluggable clamp connector 6 1 A / 5 A & 1U (100/110 V), pluggable ring lug connector Earth-fault current input, X1 A 1A/5A B 0,2 A / 1 A Nominal Supply Voltage [V], X2 A Power A 48 - 230 V (range: 40 ... 265 Vac/dc) B Power B 24 V (range: 18 ... 36 Vdc) Future option A None Digital input treshhold voltage (V) 1 24 Vac/dc 2 110 Vac/dc 3 220 Vac/dc Voltage measurements + I/O, X5 B 3U (100 / 110 V) + 6DI + 3DO I/O with comms B RS-485 + 8DI C 2 x RJ-45 + 8DI D 2 x LC + 8DI E RJ + 232 + 8DI with IRIG-B F LC + 232 + 8DI with IRIG-B Product version A Version 2.1 Region A International 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: Easergy P3 U30 Slot numbers X1 X1 A X2 B AA X5 X4 schneider-electric.com Easergy P3 Catalog | 109 Ordering Easergy P3 Advanced Easergy P3F30 configuration 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: F30 1 2G 3 4 5 6 7A 8 9 10 A A A A Application F30 Feeder protection relay Nominal Supply Voltage [V] C Power C 110 - 230 V (80 .. 265 Vac/dc, 5 x DO heavy duty, A1, SF) D Power D 24 - 48 V (18 .. 60 Vdc, 5 x DO heavy duty, A1, SF) I/O Card I G 6DI+4DO (6 x DI, 4 x DO) I/O Card II A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card III A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card IV A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) Option card I A None D 4Arc (4 x Arc sensor) K RS232 (RS232) Future option A None Analog measurement card (See application) E 3L(5 A)+4U+2Io (5/1 A+1/0,2 A) F 3L(1A)+4U+2Io (5/1 A+1/0,2 A) Communication interface I A None B RS232 (RS232, IRIG-B) C RS232+RJ (RS232, IRIG-B + Ethernet RJ-45 100 Mbs) D RS232+LC (RS232, IRIG-B + Ethernet LC 100 Mbs) N 2xRJ (Ethernet RJ 100 Mbs, RSTP, PRP) O 2xLC (Ethernet LC 100 Mbs, RSTP, PRP) P PP (Plastic / Plastic serial fibre) R GG (Glass / Glass serial fibre) Reserved A Display type B 128x128 (128 x 128 LCD matrix) C 128x128Ext (128 x 128 LCD matrix, detachable) (1 Digital input treshhold voltage (V) A 24 Vdc/ac, with conformal coating B 110 Vdc/ac, with conformal coating C 220 Vdc/ac, with conformal coating Product version A Version 2.1 Future option A None Region A International (1 By default cable length is 2 m. In case other legth is needed order separately VX001-1, Vx001-3 or VX001-5 for 1 m, 3 m and 5 m respectively. Easergy P3 F30 G - A A- AAA Slot numbers 1 2 3 4 5-6 7 8 9 10 110 | Easergy P3 Catalog schneider-electric.com Ordering Easergy P3 Advanced Easergy P3L30 configuration 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: L30 1 2G 3 4 5 6 7A 8 9 10 A A A A Application L30 Feeder protection relay with Line differential and distance protection Nominal Supply Voltage [V] C Power C 110 - 230 V (80 .. 265 Vac/dc, 5 x DO heavy duty, A1, SF) D Power D 24 - 48 V (18 .. 60 Vdc, 5 x DO heavy duty, A1, SF) I/O Card I G 6DI+4DO (6 x DI, 4 x DO) I/O Card II A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card III A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card IV A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) Option card I A None, Distance protection included S Line diff and distance FW with integrated optical diff comms. card T Line diff and distance FW with RS232 for external diff comms. converter Future option A None Analog measurement card (See application) E 3L(5 A)+4U+2Io (5/1 A+1/0,2 A) F 3L(1A)+4U+2Io (5/1 A+1/0,2 A) Communication interface I A None B RS232 (RS232, IRIG-B) C RS232+RJ (RS232, IRIG-B + Ethernet RJ-45 100 Mbs) D RS232+LC (RS232, IRIG-B + Ethernet LC 100 Mbs) N 2xRJ (Ethernet RJ 100 Mbs, RSTP) O 2xLC (Ethernet LC 100 Mbs, RSTP) P PP (Plastic / Plastic serial fibre) R GG (Glass / Glass serial fibre) Reserved A Display type B 128x128 (128 x 128 LCD matrix) C 128x128Ext (128 x 128 LCD matrix, detachable) (1 Digital input treshhold voltage (V) A 24 Vdc/ac, with conformal coating B 110 Vdc/ac, with conformal coating C 220 Vdc/ac, with conformal coating Product version A Version 2.1 Future option A None Region A International (1 By default cable length is 2 m. In case other length is needed order separately VX001-1, VX001-3 or VX001-5 for 1 m, 3 m and 5 m respectively. Easergy P3 L30 G - A A- AAA Slot numbers 1 2 3 4 5-6 7 8 9 10 schneider-electric.com Easergy P3 Catalog | 111 Ordering Easergy P3 Advanced Easergy P3M30 configuration 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: M30 1 2G 3 4 5 6 7A 8 9 10 A A A A Application M30 Motor protection relay Nominal Supply Voltage [V] C Power C 110 - 230 V (80 .. 265 Vac/dc, 5 x DO heavy duty, A1, SF) D Power D 24 - 48 V (18 .. 60 Vdc, 5 x DO heavy duty, A1, SF) I/O Card I G 6DI+4DO (6 x DI, 4 x DO) I/O Card II A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card III A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card IV A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) Option card I A None D 4Arc (4 x Arc sensor) K RS232 (RS232) Future option A None Analog measurement card (See application) E 3L(5 A)+4U+2Io (5/1 A+1/0,2 A) F 3L(1A)+4U+2Io (5/1 A+1/0,2 A) Communication interface I A None B RS232 (RS232, IRIG-B) C RS232+RJ (RS232, IRIG-B + Ethernet RJ-45 100 Mbs) D RS232+LC (RS232, IRIG-B + Ethernet LC 100 Mbs) N 2xRJ (Ethernet RJ 100 Mbs, RSTP) O 2xLC (Ethernet LC 100 Mbs, RSTP) P PP (Plastic / Plastic serial fibre) R GG (Glass / Glass serial fibre) Reserved A Display type B 128x128 (128 x 128 LCD matrix) C 128x128Ext (128 x 128 LCD matrix, detachable) (1 Digital input treshhold voltage (V) A 24 Vdc/ac, with conformal coating B 110 Vdc/ac, with conformal coating C 220 Vdc/ac, with conformal coating Product version A Version 2.1 Future option A None Region A International (1 By default cable length is 2 m. In case other length is needed order separately VX001-1, VX001-3 or VX001-5 for 1 m, 3 m and 5 m respectively. Easergy P3 M30 G - A A- AAA Slot numbers 1 2 3 4 5-6 7 8 9 10 112 | Easergy P3 Catalog schneider-electric.com Ordering Easergy P3 Advanced Easergy P3M32 configuration M32 1 2G 3 4T 5A 6 7A 8 9 10 A A A A Application M32 Motor protection relay with differential protection Nominal Supply Voltage [V] C Power C 110 - 230 V (80 .. 265 Vac/dc, 5 x DO heavy duty, A1, SF) D Power D 24 - 48 V (18 .. 60 Vdc, 5 x DO heavy duty, A1, SF) I/O Card I G 6DI+4DO (6 x DI, 4 x DO) I/O Card II A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card III T 3xI (5/1A) + Io (5/1A) for motor differential protection I/O Card IV A None Option card I A None D 4Arc (4 x Arc sensor) K RS232 (RS232) Future option A None Analog measurement card (See application) E 3L(5 A)+4U+2Io (5/1 A+1/0,2 A) F 3L(1A)+4U+2Io (5/1 A+1/0,2 A) Communication interface I A None B RS232 (RS232, IRIG-B) C RS232+RJ (RS232, IRIG-B + Ethernet RJ-45 100 Mbs) D RS232+LC (RS232, IRIG-B + Ethernet LC 100 Mbs) N 2xRJ (Ethernet RJ 100 Mbs, RSTP) O 2xLC (Ethernet LC 100 Mbs, RSTP) P PP (Plastic / Plastic serial fibre) R GG (Glass / Glass serial fibre) Reserved A Display type B 128x128 (128 x 128 LCD matrix) C 128x128Ext (128 x 128 LCD matrix, detachable) (1 Digital input treshhold voltage (V) A 24 Vdc/ac, with conformal coating B 110 Vdc/ac, with conformal coating C 220 Vdc/ac, with conformal coating Product version A Version 2.1 Future option A None Region A International (1 By default cable length is 2 m. In case other length is needed order separately VX001-1, VX001-3 or VX001-5 for 1 m, 3 m and 5 m respectively. 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: Easergy P3 M32 G T A- A A- Slot numbers 1 2 3 4 5-6 7 8 9 10 AAA schneider-electric.com Easergy P3 Catalog | 113 Ordering Easergy P3 Advanced Easergy P3T32 configuration T32 1 2G 3 4T 5A 6 7A 8 9 10 A A A A Application T32 Transformer protection relay with differential protection Nominal Supply Voltage [V] C Power C 110 - 230 V (80 .. 265 Vac/dc, 5 x DO heavy duty, A1, SF) D Power D 24 - 48 V (18 .. 60 Vdc, 5 x DO heavy duty, A1, SF) I/O Card I G 6DI+4DO (6 x DI, 4 x DO) I/O Card II A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card III T 3xI (5/1A) + Io (5/1A) for transformer differential protection I/O Card IV A None Option card I A None D 4Arc (4 x Arc sensor) K RS232 (RS232) Future option A None Analog measurement card (See application) E 3L(5 A)+4U+2Io (5/1 A+1/0,2 A) F 3L(1A)+4U+2Io (5/1 A+1/0,2 A) Communication interface I A None B RS232 (RS232, IRIG-B) C RS232+RJ (RS232, IRIG-B + Ethernet RJ-45 100 Mbs) D RS232+LC (RS232, IRIG-B + Ethernet LC 100 Mbs) N 2xRJ (Ethernet RJ 100 Mbs, RSTP) O 2xLC (Ethernet LC 100 Mbs, RSTP) P PP (Plastic / Plastic serial fibre) R GG (Glass / Glass serial fibre) Reserved A Display type B 128x128 (128 x 128 LCD matrix) C 128x128Ext (128 x 128 LCD matrix, detachable) (1 Digital input treshhold voltage (V) A 24 Vdc/ac, with conformal coating B 110 Vdc/ac, with conformal coating C 220 Vdc/ac, with conformal coating Product version A Version 2.1 Future option A None Region A International (1 By default cable length is 2 m. In case other length is needed order separately VX001-1, VX001-3 or VX001-5 for 1 m, 3 m and 5 m respectively. 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: Easergy P3 T32 G T A- A A- Slot numbers 1 2 3 4 5-6 7 8 9 10 AAA 114 | Easergy P3 Catalog schneider-electric.com Ordering Easergy P3 Advanced Easergy P3G30 configuration 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: G30 1 2G 3 4 5 6 7A 8 9 10 A A A A Application G30 Generator protection Nominal Supply Voltage [V] C Power C 110 - 230 V (80 .. 265 Vac/dc, 5 x DO heavy duty, A1, SF) D Power D 24 - 48 V (18 .. 60 Vdc, 5 x DO heavy duty, A1, SF) I/O Card I G 6DI+4DO (6 x DI, 4 x DO) I/O Card II A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card III A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card IV A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) Option card I A None D 4Arc (4 x Arc sensor) K RS232 (RS232) Future option A None Analog measurement card (See application) E 3L(5 A)+4U+2Io (5/1 A+1/0,2 A) F 3L(1A)+4U+2Io (5/1 A+1/0,2 A) Communication interface I A None B RS232 (RS232, IRIG-B) C RS232+RJ (RS232, IRIG-B + Ethernet RJ-45 100 Mbs) D RS232+LC (RS232, IRIG-B + Ethernet LC 100 Mbs) N 2xRJ (Ethernet RJ 100 Mbs, RSTP) O 2xLC (Ethernet LC 100 Mbs, RSTP) P PP (Plastic / Plastic serial fibre) R GG (Glass / Glass serial fibre) Reserved A Display type B 128x128 (128 x 128 LCD matrix) C 128x128Ext (128 x 128 LCD matrix, detachable) (1 Digital input treshhold voltage (V) A 24 Vdc/ac, with conformal coating B 110 Vdc/ac, with conformal coating C 220 Vdc/ac, with conformal coating Product version A Version 2.1 Future option A None Region A International (1 By default cable length is 2 m. In case other length is needed order separately VX001-1, VX001-3 or VX001-5 for 1 m, 3 m and 5 m respectively. Easergy P3 G30 G - A A- AAA Slot numbers 1 2 3 4 5-6 7 8 9 10 schneider-electric.com Easergy P3 Catalog | 115 Ordering Easergy P3 Advanced Easergy P3G32 configuration G32 1 2G 3 4T 5A 6 7A 8 9 10 A A A A Application G32 Generator protection with differential protection Nominal Supply Voltage [V] C Power C 110 - 230 V (80 .. 265 Vac/dc, 5 x DO heavy duty, A1, SF) D Power D 24 - 48 V (18 .. 60 Vdc, 5 x DO heavy duty, A1, SF) I/O Card I G 6DI+4DO (6 x DI, 4 x DO) I/O Card II A None G 6DI+4DO (6 x DI, 4 x DO) H 6DI+4DO (6 x DI, 4 x DO(NC)) I 10DI (10 x DI) I/O Card III T 3xI (5/1A) + Io (5/1A) for generator differential protection I/O Card IV A None Option card I A None D 4Arc (4 x Arc sensor) K RS232 (RS232) Future option A None Analog measurement card (See application) E 3L(5 A)+4U+2Io (5/1 A+1/0,2 A) F 3L(1A)+4U+2Io (5/1 A+1/0,2 A) Communication interface I A None B RS232 (RS232, IRIG-B) C RS232+RJ (RS232, IRIG-B + Ethernet RJ-45 100 Mbs) D RS232+LC (RS232, IRIG-B + Ethernet LC 100 Mbs) N 2xRJ (Ethernet RJ 100 Mbs, RSTP) O 2xLC (Ethernet LC 100 Mbs, RSTP) P PP (Plastic / Plastic serial fibre) R GG (Glass / Glass serial fibre) Reserved A Display type B 128x128 (128 x 128 LCD matrix) C 128x128Ext (128 x 128 LCD matrix, detachable) (1 Digital input treshhold voltage (V) A 24 Vdc/ac, with conformal coating B 110 Vdc/ac, with conformal coating C 220 Vdc/ac, with conformal coating Product version A Version 2.1 Future option A None Region A International (1 By default cable length is 2 m. In case other length is needed order separately VX001-1, VX001-3 or VX001-5 for 1 m, 3 m and 5 m respectively. 1. Choose your option 2. Mark your choice in the box below 3. Check your order code: Easergy P3 G32 G T A- A A- Slot numbers 1 2 3 4 5-6 7 8 9 10 AAA 116 | Easergy P3 Catalog schneider-electric.com Ordering Accessories Arc point sensors Comm. Ref REL52801 REL52802 REL52803 REL52804 REL52805 REL52806 REL52807 REL52808 REL52809 REL52810 Description VA1DA-20 VA1DA-20S-HF VA1DA-20S VA1DA-6 VA1DA-6S-HF VA1DA-6S VA1EH-20 VA1EH-20S VA1EH-6 VA1EH-6S RTD Modules Comm. Ref REL52811 REL52812 REL52813 REL52814 Description VIO12AASE VIO12ABSE VIO12ACSE VIO12ADSE Communication Port Comm. Ref REL52815 REL52820 REL52821 Description VPA3CGSE VSE002 VSE009 Fiber optic modules Reference REL52816 REL52817 REL52818 REL52819 Description VSE001-GGSE VSE001-GPSE VSE001-PGSE VSE001-PPSE Others accessories Reference REL52822 REL52828 REL52829 REL52831 REL52832 REL52823 REL52824 REL52834 REL52833 REL52825 REL52826 REL52827 REL52835 Description USB cable VYX001 VYX002 VYX301 VYX695 VX067 VX072 VYX860 P3UPSC VX082 VX083 VX084 VX085 Arc sensor, 20m Arc sensor, 20m, shielded, halogen free Arc sensor, 20m, shielded Arc sensor, 6m connect cable Arc sensor, 6m, halogen free Arc sensor, 6m, shielded Arc sensor, 20m pipe sensor Arc sensor, 20m pipe sensor, shielded Arc sensor, 6m pipe sensor Arc sensor, 6m pipe sensor, shielded RTD module, 12pcs RTD inputs, Optical Tx RTD module, 12pcs RTD inputs, RS485 RTD module, 12pcs RTD inputs, mA in/out RTD module, 12pcs RTD inputs, mA in/out Profibus interface module PM106585 RS485 module PM106581 DeviceNet module PM106580 Fiber optic module (Glass - Glass) PM106586 Fiber optic module (Glass - Plastic) PM106586 Fiber optic module (Plastic - Glass) PM106586 Fiber optic module (Plastic - Plastic) PM106586 USB programming cable (Easergy Pro) Mounting plate for arc sensor Z-shape Mounting plate for arc sensor L-shape VSE00x wall fastening module Raising frame, P3x, 45 mm Split cable for COM 1-2 & COM 3-4 ports Profibus cable Raising frame, P3U, 45 mm P3U panel seal cover RS232 - VSE (1xD9) cable RS232 - Remote/Ext. (3xD9) cable RS232 - VPA 3CG cable (Profibus) P3U (RS232) - VSE009 cable Used on P3F3x / P3M3x P3T3x / P3G3x Used on P3Ux0 / P3F3x P3L3x / P3M3x P3T3x / P3G3x Used on P3Ux0 / P3F3x P3L3x / P3M3x P3T3x / P3G3x Used on P3Ux0 / P3F3x P3L3x / P3M3x P3T3x / P3G3x Used on P3Ux0 / P3F3x P3L3x / P3M3x P3T3x / P3G3x P3F3x P3L3x / P3M3x P3T3x / P3G3x P3Ux0 schneider-electric.com Easergy P3 Catalog | 117 Notes 118 | Easergy P3 Catalog schneider-electric.com Notes schneider-electric.com Easergy P3 Catalog | 119 Schneider Electric Industries SAS 35 rue Joseph Monier 92500 Rueil-Malmaison, France Tel : +33 (0)1 41 29 70 00 www.schneider-electric.com NRJCAT17764EN_v14c �2018 Schneider Electric SE. All Rights Reserved. All Schneider Electric trademarks and service marks are the property of Schneider Electric SE, its subsidiaries and affiliated companies.