Xenon sounder beacon for conventional fire systems | Eaton
Fire systems and devices Product catalogue JSB Complete fire systems for the protection of life and property We make what matters work.* Every day, people depend on things like technology, transportation, energy and infrastructure to keep their daily lives on track. But without power, none of it would be possible. That's why companies around the world turn to Eaton. We're dedicated to improving people's lives and the environment with innovative technologies that help manage power more safely, reliably and sustainably. To meet today's challenges, and tomorrow's. Because this is what really matters. And we're here to make sure it works. To learn more go to: Eaton.com/whatmatters We make what matters work. * Leadenhall Building London, UK 4 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Introduction Distinctive capabilities Excellence and innovation in fire safety solutions. When it comes to protecting life and property there's no room to compromise. You need a partner that can support you with tried and tested products, global capabilities and local delivery. Eaton is a leading manufacturer and global supplier of high quality fire systems. With our ability to provide complete systems, not just components, you can be confident in the knowledge that all of our products have been specifically designed and tested to ensure that they are all fully compatible to form a reliable and compliant fire detection and alarm system. Our large multi-disciplined research and development team is responsible for the integration of the latest technology into the full range of fire products, ensuring that our products are designed to the latest fire industry standards and manufactured to the highest levels of quality. The many innovative, new and improved products featured in this catalogue demonstrate our commitment to staying at the leading edge of technological development for fire detection and alarm equipment. Our core values and aims are: · Investment in people · To partner with our customers to develop open, long term relationships · To have an unpretentious, straightforward and honest approach to business · The continued investment in research and development · Investment in manufacturing facilities to ensure they remain world class · To produce products that are in full compliance with standards · To operate in an environmentally friendly way - in the products we design and the facilities in which we make them · To have high ethical standards Our solutions and services are recognised by a wide range of accreditation bodies, so you can count on products that comply with national and industry standards, while receiving full support, from initial system design to monitoring and service. SS PREVENT LO ION CERTIFI LPCB RD CATIO N BOA SIGNALING 4AC5 FIRE ALARM EQUIPMENT EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 5 Introduction Distinctive capabilities Ankara Esenboa International Airport Ankara, Turkey St Pancras Station London, UK 6 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Doncaster Cultural and Civic Quarter Doncaster, UK Introduction Distinctive capabilities Manufacturing fire solutions is just one small element of what we do. Services We believe that ownership of fire detection systems extends beyond the initial purchase of the products themselves. We therefore offer customers a wide range of services to ensure that their installations not only meet basic operational and safety requirements on day one, but will continue to do so throughout their lifetime. From training and support on how to select products for a specific application through to the provision of routine on-site testing and maintenance. You can be sure that Eaton is ready to support you, whatever your needs. Major projects Design and installation of a fire detection system can often be a complex process, with each project often bringing its own challenges in making sure the system is compliant, reliable and easy to operate. Our team of engineers will partner with your project management team using our expertise to meet the specific requirements of your project. Eaton has a great deal of experience handling major projects across the globe. We can help not just with the product and technical support but also by providing guidance and advice to specifiers and project management teams on topics such as standards and regulations. We are BAFE SP203 certified for design, commissioning and maintenance of fire detection systems, giving our customers the peace of mind they need that our systems conform with all necessary safety requirements. Technical support Our dedicated technical support team are able to offer customers around the world advice and guidance on a wide variety of technical matters via telephone or email. In the vast majority of cases, a process of systematic questioning enables the team to diagnose the challenge and advise the customer on the appropriate solution. Sometimes more detailed troubleshooting and analysis methods may be used to determine the actual requirements and the best way of resolving it. If necessary, the technical support team will also call on the knowledge and expertise of Eaton's product management, R&D and design departments to help resolve the customer's issue. In addition, the technical support team can provide customers with assistance on product information, installation and operating instructions, and the legislative requirements of your fire detection systems. EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 7 Introduction Contents Mariner's Quay Apartment Complex Newport 8 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Introduction Contents Contents 1. Introduction An introduction to fire systems 10 Conventional and two-wire systems 12 Addressable systems 13 Emergency voice communication systems 14 UL listed fire systems 15 Voice alarm systems 15 2. Intelligent addressable systems Fire panels and repeater panels 18 Addressable devices 24 3. UL intelligent addressable systems Fire panels and repeater panels 48 UL listed devices 50 4. Conventional systems Fire panels and repeater panels 62 Conventional devices 70 5. Appendix Notes 87 Contact details 89 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 9 Introduction An introduction to fire systems An introduction to fire systems Eaton manufacture and supply a range of different types of fire systems, meaning we can provide a high quality fire solution whatever your need is. There are a vast array of fire detection systems and devices on the market today, ranging from the relatively simple to the most technically sophisticated. Modern automatic fire detection systems are available in two types, conventional and addressable - which, broadly speaking, tend to be used in smaller and larger installations respectively. For more detail you can read our fire systems guide over the next few pages. The basics of fire detection A control panel is the hub of the detection system. All the devices which are part of the fire detection system are connected to this central panel which processes the signals received from the input devices and gives out signals to the output devices. Input devices such as detectors measure signals of combustion and communicate with panels, which in turn trigger output devices such as an audible or visual alarm device. Fire alarm panels can be further sub segmented into addressable or conventional panels. There are various types of fire detection systems each suited to different applications or building types. A fire detection system can vary significantly in both complexity and price, from a single panel with a detector and sounder in a small commercial property to a complex intelligent addressable system in a multi-occupancy building. A fire detection system can comprise of detection devices, notification devices and manual callpoints. The size of the building determines the number of detectors that would be required. The system works via the control panel receiving signals from the detection devices and then sending transmitting signals to the notification devices. 10 EATON - FIRE ASYNSDTVEOMISCEAANLDADREMVSICYESSTECMFS-CC2F-5C5C625A5u6guJsutn2e0219017 Introduction An introduction to fire systems EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 11 Introduction Conventional fire systems Conventional systems (p61-85) Two-wire systems The philosophy of a conventional system revolves around dividing the building into a number of areas called zones. The detectors and call points within each zone are then wired on a dedicated separate circuit. Two-wire systems are based on standard conventional system technology, but it also incorporates additional functionality to enable the callpoints, detectors and sounders for each separate zone to be wired on a single common circuit. In the event of a detector or call point being triggered, the panel is able to identify which circuit contains the triggered device and thereby indicate which zone the fire alarm has come from. The indicated zone can then be manually searched to locate the triggered device. By combining both the detection and the alarm annunciation wiring into a single circuit, considerable savings in installation time and cabling can be achieved. With this type of functionality a conventional system is best used in smaller builds where it wouldn't be difficult to locate the triggered device in a given zone. Zone 1 Zone 2 Typical conventional system architecture Zone 3 Zone 4 Typical two-wire system architecture Example conventional system layout Example two-wire system layout 12 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Introduction Addressable fire systems Addressable systems (p17-44) Intelligent addressable systems overcome the limitations of conventional systems as each fire detecting sensor or call point is electronically coded with a unique identification or 'address' which is programmed into the device during installation. By using each devices' unique address, the control panel is able to conduct two way communication with any of the addressable devices connected to the system. Under normal conditions the control panel continuously interrogates each device in sequence and analyses the reply to determine the status of each sensor or call point. The panel checks whether each device is functioning correctly and also the amount of smoke or heat that the device is currently sensing. With the functionality of being able to pinpoint exactly which device is being triggered in an alarm or for a fault, addressable systems are perfect for mid to large size builds with multiple rooms and floors. Zone 1 Zone 2 15 16 14 1 2 3 13 4 12 11 10 9 5 6 8 7 Zone 3 Zone 4 Typical addressable system architecture Example addressable system layout EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 13 Introduction Emergency voice communication systems UL listed fire systems (p46-59) Underwriters Laboratories Inc. (UL) is an independent product safety certification organisation, established in 1894, to develop standards and test procedures for products, materials, components, assemblies, tools and equipment. Chiefly dealing with product safety it also evaluates and certifies the efficiency of a company's business processes through its magnificent system registration programs. Since the launch of our UL Listed fire product range, several prestigious projects worldwide have been supplied including Hyatt Resort and Spa, Shangri-la at the Fort and Times Square projects in South East Asia and several major projects in the Middle East including the prestigious Riyadh Financial District in the Kingdom of Saudi Arabia. The Eaton UL range is designed to provide a solution for all sizes of project, from the simple small stand alone system to the large multi panel networked system with PA/VA and BMS integration. SIGNALING 4AC5 FIRE ALARM EQUIPMENT 14 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Notes EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 15 16 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Intelligent addressable systems Contents Contents Intelligent addressable systems Panels FX2000 addressable panel 18 FX6100 addressable panel 20 FX6000 addressable panel 22 Devices Sensors 24 Bases 26 Callpoints 28 Wall sounders and VADs 29 Beam detector 33 Duct probe 33 Interfaces 34 Micro interfaces 38 Networking interfaces 39 Ancillaries 41 Software 43 Test equipment 44 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 17 Intelligent addressable systems FX2000 FX2000 Intelligent addressable control panel "The FX2000 serves as the optimum solution for buildings requiring smaller addressable systems." The Eaton FX2000 is an entry level intelligent Benefits addressable control panel which can be configured for either 1 or 2 loop operation, and is certified to EN54 parts 2 & 4. · Configurable as a 1 or 2 loop panel · Up to 200 addresses per loop (up to 60 sounders/beacons and up to 20 I/Os, subject The panel has a graphic display, providing a simple menu driven end user interface. With the FX2000's ability to support Eaton cause and effect to loop loading calculations) · Soft addressing · Menu-driven graphic screen programming and a range of user controllable · Multi-language selection capability functions it makes the panel suitable for a varied · Integral battery and power supply range of projects from small warehouses to small/ medium office developments as well as many small industrial applications. · 2x7Ah batteries included · Easy to operate end user controls · Full system integrity with Eaton developed As with all Eaton intelligent addressable panels, the FX2000 uses "spur tolerant" soft addressing to protocol · Core range of compatible devices minimise installation time and remove the potential · 4 sounder circuits for errors often associated with many forms of · Monitored for open and short circuit (max manual addressing. 3.0A combined) ION CERTIFI 18 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 LPCB SS PREVENT CATIO N BOA RD LO Dimensions W H Intelligent addressable systems FX2000 Compatible repeater panels The FX2000 has a standard repeater panel available. Ideal for larger sites, the repeater allows you to display the system information from multiple locations. H (mm) 400 W (mm) 320 D D (mm) 170 Features FX2000 Ingress protection IP30 Catalogue numbers Description Code Addressable 2 loop control panel, standalone (FX2000) 910188FULL-0199 Addressable passive repeater FX6000PR Fire alarm system log book MFALOG Features Active or passive option Integral battery and power supply Supervisor and engineer modes through code access Ingress protection FX6000PR IP30 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 19 Intelligent addressable systems FX6100 FX6100 Intelligent addressable control panel "The simplicity of operation, powerful cause and effect programming capability and competitive pricing make the system suitable for a wide range of small to medium sized projects." The FX6100 is a high specification addressable panel for medium sized builds that is equipped with a versatile touch screen user interface. It is available as a 1 (FX6100) or 2 (FX61002) loop panel. The powerful cause and effect programming capability and competitive pricing make the system suitable for a wide range of small to medium sized projects. The panels can operate as standalone or as part of a network with our other addressable panels (additional network card required). FX6100 FX61002* No. of loops 1* 2* Addresses per loop 200** 200** No. of conventional sounder circuits 2*** 2*** Ingress protection IP30 IP30 * No zonal LEDs ** Up to 60 sounders/beacons and up to 20 I/Os ***Monitored for open and short circuit (max 1.5A combined) Benefits · Soft addressing · Large versatile touch screen user interface · Multi-language selection capability · Integral battery and power supply · 2x7Ah batteries included · Flexible distributed network capability · Full range of compatible devices · Flexible and easy to design, system cause and effect using site installer software · Compatible with our addressable repeaters (see p21) 20 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Approved product Dimensions D W H Panel Cutout H (mm) 375 345 W (mm) 357 325 D1 (mm) 95 50 Intelligent addressable systems FX6100 FX6100 pictured with a range of compatible devices Catalogue numbers Description 1 Loop Control Panel, VDS 2 Loop Control Panel, VDS Add to end of product code if network card required Dual redundancy network card Network Kit for DF6100/2 and CF11/CF12 Passive repeater panel Touch-screen repeater panel Fire routing equipment PCB Fire alarm system log book Code FX6100 FX61002 NC NCDR DF61NETKIT FX6000PR FTPR6000 ZPCB2187FRE MFALOG EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 21 Intelligent addressable systems FX6000 FX6000 Intelligent addressable control panel "The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects" The FX6000 series are high specification intelligent addressable control panels, which are fully certified to EN54 parts 2 and 4. Benefits · Soft addressing · Large versatile touch screen user interface Each panel is networkable with up to 126 other Eaton addressable control panels, only requiring the addition of one of our network cards for this functionality. Using our latest software, the panels can be set up for smoke management protocols, when used in conjunction with FC6 or FC18 fan controller units, and the new MCOM-FC interface module. · Multi-language selection capability · Integral printer (optional) · Integral battery and power supply · 2x 12Ah batteries included · Extended battery option allows for 72 hours standby (subject to loop loading calculations) · Flexible distributed network capability FX60002 FX60004 · Full range of compatible devices No. of Loops 2 4 · Easy to design system cause and effect using Addresses per Loop 200* 200* site installer software No. of Conventional 4** 4** Sounder Circuits · Additional functionality through FRE & FPE Ingress protection IP30 IP30 (Fire Routing Equipment & Fire Protection * Up to 60 sounders/beacons and up to 20 I/Os **Monitored for open and short circuit (max 1.5A combined) Equipment) which are both monitored outputs ION CERTIFI 22 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 LPCB SS PREVENT CATIO N BOA RD LO Intelligent addressable systems FX6000 Class change functionality Our FX6000 panel has a variety of easy to use additional software options on top of the standard class change facility; this provides benefits for a number of regions. Class change input on the FX6000 can be used for functions such as Australian Fire Brigade, HMO operation, Swedish mode, Australian tone sounders for class change and different tones. Compatible repeater panels The FX6000 has both a passive and a touchscreen repeater panel available. Ideal for larger sites, the repeater allows you to display the system information at multiple locations. Features FX6000PR Active or passive option No programming required * Programmable input Integral battery and power supply Supervisor and engineer modes through code access Fire and fault volt free programmable relays Adjustable volume from panel Ingress protection IP30 *Programming not required on network version. FTPR6000 IP30 Dimensions D2 W H D1 Standard H (mm) 397 W (mm) 497 D1 (mm) 55 D2 (mm) 125 Catalogue numbers Description 2 loop control panel 4 loop control panel 2 loop control panel, integral printer 4 loop control panel, integral printer Add to end of product code if network card required If an additional loop card is required Network Kit for FX6000 Printer kit (for retro fit) Hinged protective cover kit Passive repeater panel Touch-screen repeater panel Fire alarm system log book Code FX60002 FX60004 FX60002P FX60004-P NC ZPCB2148P2 DF6000NETKIT DF6000PKIT DF6000COV FX6000PR FTPR6000 MFALOG EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 23 Intelligent addressable systems Devices - sensors Sensors Our addressable range has multiple options for intelligent addressable sensors. All sensors are designed for optimum functionality in mid-large sized builds. They are all soft addressed and have integral short circuit isolators. We also offer a loop connected remote indicator, designed to offer discreet remote indication and an ability to monitor multiple sensors. This helps to minimise wiring requirements. Optical smoke sensor Photo-thermal sensor Heat sensor FXN723 FXN722* FXN725 Typical applications: Suitable for most applications. Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. Typical applications: Responds quickly to fast clean burning fires. Maintains the advantage of optical sensors when detecting smouldering fires. Typical applications: Environments where the ambient conditions might cause false alarms with smoke detectors. Examples include areas with high levels of dust or fumes. The FXN725 can operate in 3 modes: rate of rise, fixed heat 77°C and fixed heat 90°C. These modes are set by the panel. *The FXN722 has day/ night modes available, programmeable from the site installer software. The day mode uses the heat aspect of the sensor for areas which may have smoky environments during, for example working hours. The night mode uses a combination of A2S and smoke detection. If not programmed, the sensor defaults to dual mode. Dimensions Performance Dia Feature FXN723 FXN722 FXN725 FXN725 FXN725 Mode Area coverage* Optical 100m2 Photothermal 100m2 Rate of rise 50m2 Fixed Fixed heat 77°C heat 90°C 50m2 50m2 Heat class N/A A2S A2R BS CS D1 D2 Alarm temperature N/A 60 °C 60 °C 77 °C 92 °C Ingress protection IP30 IP30 IP30 IP30 IP30 *(subject to local standards) Description Optical Photo-thermal Heat Diameter (mm) Depth (mm) (incl base) (excl base) 104 33 104 43 104 43 Depth (mm) (incl base) 45 55 55 Catalogue numbers Description Optical smoke sensor - FXN723 Photo-thermal sensor - FXN722 Multi-mode heat sensor - FXN725 Code 400002FIRE-0005X 400004FIRE-0007X 400003FIRE-0006X 24 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 ION CERTIFI LPCB SS PREVENT CATIO N BOA RD LO Intelligent addressable systems Devices - sensors Indicators Our indicators are designed as additional indication devices when sensors have been triggered. These products are designed to be used as indicators only, and not visual alarm devices (see p26 and 29 for EN54-23 certified VADs). Addressable remote indicator MRIAD Standard remote indicator FX251D Staff warning device FXN338BCN Typical applications: Monitoring multiple sensors within a specific area. Must be configured through site installer. The remote indicator can be programmed as a sounder. Typical applications: The FX251D can only be connected to one sensor and is powered by this sensor. There is a weather resistant version also available. (Not IP65). Typical applications: As this product does not meet EN54-23 requirements as a beacon we recommend it as an internal warning device in offices, schools or manned reception areas. Remote indicator lens detail Dimensions D D H Dia Staff warning device Description Staff warning device Diameter (mm) 101 Description Remote indicators Height (mm) 87 W Remote indicators Depth (mm) 33 Width (mm) 87 Depth (mm) 30 Catalogue numbers Description Loop connected remote indicator Standard remote indicator Weather resistant standard remote indicator Staff warning device Code MRIAD FX251D CIR301WP FXN338BCN EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 25 Intelligent addressable systems Accessories - bases Bases We stock a variety of bases, providing a wide functionality for different situations. The standard base (FXN720) provides a foundation for our addressable sensors. The range of bases also includes capability for additional sounder and sounder beacon operation. Both our sounder base (FXN538) and VAD sounder beacon base (FXN577) can be used as standalone devices when fitted with our cover plate (CASC). Standard base FXN720 Sounder base FXN538 Sounder beacon base FXN557 (FXN537) Sounder base with cover FXN538 + CASC Typical applications: General use product, recommended for use in all environments Typical applications: Areas of limited extent, where lower output volume is required Areas with limited cable space Concrete ceilings, to save cabling 0.5Hz FLASH Typical applications: The FXN577 is an EN54-23 certified Visual Alarm Device (VAD) sounder beacon base. It is compatible with the Eaton range of intelligent addressable sensors and can also be used as a dedicated discreet standalone device. (The FXN577 sounder beacon base is also available for indication purposes, where EN 54-23 is not a requirement.) Typical applications: Optional cover plate can be used to enable the sounder to operate as a dedicated discreet stand alone device Features First fix base Loop integrity switch Multiple cable entry points Selectable tones Ingress protection FXN720 FXN538 IP40 FXN537 IP40 FXN557 IP21C VAD sounder beacon base shown with optical sensor 26 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 ION CERTIFI LPCB SS PREVENT CATIO N BOA RD LO Intelligent addressable systems Accessories - bases Performance Sound output Low volume Medium volume High volume FXN538 84dB at < 4mA 92dB at < 8mA 95dB at < 12mA FXN557 77dB at < 6.6mA 89dB at < 8mA 90dB at < 9mA Flash rate n/a 0.5 Hz flash* *Polar dispersion infromation available on datasheet Dimensions D D Dia D Dia Standard base Description Standard base Sounder base Sounder beacon base Dia Sounder base Sounder beacon base Diameter (mm) 104 102 115 Depth (mm) 22 40 44 Catalogue numbers Description Standard base Sounder base VAD sounder beacon base Sounder beacon base Cover plate (pack of 5) Base shroud Code FXN720 FXN538 FXN557 FXN537 CASC BAR3000-1 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 27 Intelligent addressable systems Devices - callpoints Callpoints Two versions of the intelligent addressable callpoint are available, the surface/ flush mounted FXN501 or the weatherproof FXN503. Both have an integral short circuit isolator and are very simple to install. The callpoints are packaged with 2 frangible glass elements and test key, with a comprehensive range of further accessories available. Surface/flush mounted Weatherproof callpoint callpoint FXN503 FXN501 Dimensions W H Typical applications: General use product, suitable for use in most indoor applications. Typical applications: Builds requiring a callpoint in harsh conditions. For example, outside or in a wash down area. D Description Surface mounted Flush mounted Weatherproof H (mm) 87 87 87 W (mm) 87 87 87 D (mm) 36 57 59 Features Fast fit clip High Visibility LED Heavy duty terminals Ingress protection FXN501 IP42 FXN503 IP65 Further accessories: Catalogue numbers Description Code Surface/flush callpoint FXN501 Weatherproof callpoint FXN503 CXPC Protective hinged cover (pack of 10) CXPC MBGBEZ Recessing bezels (pack of 10) MBGBEZ MBGREKIT Resettable element kit (pack of 10) MBGREKIT Spare break glasses (pack of 5) FX5G MFBGKEY3 Callpoint keys (pack of 10) MFBGKEY3 28 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Callpoint shown with protective hinged cover Callpoint recessing bezel ION CERTIFI LPCB SS PREVENT CATIO N BOA RD LO Intelligent addressable systems Devices - wall sounders Wall sounders and VADs There are also two versions of our intelligent addressable wall sounder, the internal (FXN538LPS) and the weatherproof (FXN538LPSWP). Their highly efficient design offers excellent sound output levels despite the low current consumption. They both contain an integral short circuit isolator and have multiple tones and volume levels which can be controlled from the panel globally, or individually via site installer. We also offer a new open class Visual Alarm Device (MASB880), combining the high output sound of the wall sounders with a stronger LED to meet the EN54-23 VADs requirements. The open class functionality allows the VADs to be installed in open areas such as warehouses or airport terminals. Wall sounder VAD wall Dimensions FXN538LPS/ sounder beacon FXN538LPSWP FXN559LPS/ w D FXN559LPSWP D FXN539LPS/FXN539LPSWP 0.5Hz FLASH H H Typical applications: Both an indoor and weatherproof variant of the wall sounder are available, allowing for consistent performance for any application where a wall sounder is required. Typical applications: The FXN599 is an addressable open class VAD suitable for all markets where EN54-23 VADs are now a requirement. White flash only. (The FXN539LPS wall sounder beacon is also available for indication purposes, where EN 54-23 is not a requirement. Red flash only.) W Internal wall sounder / sounder beacon Description Wall sounder WP wall sounder VAD sounder beacon WP VAD sounder beacon H (mm) 105 108 108 110 Weatherproof wall sounder/ sounder beacon W (mm) 105 108 108 110 D (mm) 95 103 96 105 Tones Continuous Two tone @ 1Hz cycle Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap Pulsed 1Hz (Virtual Tone) Pulsed sweep ISO8201 3x500ms 800-970Hz 1½ Sec Gap Bell tone Sound output FXN538LPS/ FXN538LPSWP Low volume 87dB at < 2mA Medium volume 93dB at < 3mA High volume 100dB at < 6mA Flash rate n/a FXN538LPS/ FXN559LPS/ FXN539LPS Ingress protection IP42 ION CERTIFI LPCB FXN559LPS/ FXN559LPSWP 87dB at < 8.6mA 93dB at < 10mA 100dB at < 11mA 0.5Hz Flash FXN538LPSWP/ FXN559LPSWP/ FXN539LPSWP IP66 FXN538LPS/ FXN538LPSWP Catalogue numbers Description Internal wall sounder Weatherproof wall sounder Vad wall sounder beacon Weatherproof VAD wall sounder beacon Wall sounder beacon Wall sounder beacon weatherproof FXN559LPS/ FXN559LPSWP Code FXN538LPS FXN538LPSWP FXN559LPS FXN559LPSWP FXN539LPS FXN539LPSWP EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 29 SS PREVENT CATIO N BOA RD LO Intelligent addressable systems Devices - wall sounders Wall sounder VAD Dimensions CASB493/CASB493WP CASB483/ CASB483WP NEW PRODUCT Typical applications: This EN 54-23 compliant sounder beacon visual alarm device (VAD) is suitable for fire notification in commercial buildings. The weatherproof variant, with an IP66 ingress protection rating, can be used in wet and outdoor environments. Red (CASB483/WP) or white (CASB493/WP) flash options available. Wall sounder VAD Description Wall sounder VAD Wall sounder VAD (weatherproof) H (mm) 147 151 W (mm) 106 111 D (mm) 92 100 Wall sounder VAD (weatherproof) Wall VAD CAB492W/CAB482W Dimensions NEW PRODUCT Typical applications: A low-profile, low-current solution to the latest EN 54-23 fire standard, this fire alarm beacon VAD. It is also compatible with a range of bases making it suitable for a variety of applications. Red (CAB482W) or white (CAB492W) flash options available. Wall VAD (shallow base) Description Wall VAD (shallow base) Wall VAD (deep base) H (mm) 93 93 W (mm) 93 93 D (mm) 38 67 Wall VAD (deep base) 30 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 - Ceiling VAD Dimensions CAB492CS/CAB482CS Intelligent addressable systems Devices - wall sounders NEW PRODUCT Typical applications: This EN 54-23 certified, lowcurrent fire alarm beacon is suitable for ceiling mounting. It is compatible with a shallow base providing flexibility as to where the VAD can be installed. Red (CAB492CS) or white (CAB482CS) flash options Description Ceiling VAD Ceiling VAD H (mm) 93 W (mm) 93 D (mm) 38 Tones Flash rate (low power consumption) Operating current (depending on setting and LED colour) IP protection CASB493/CASB493WP CASB483/CASB483WP 0.5Hz 13.4-47.5mA IP21C WP variant : IP66 CAB492W/CAB482W 0.5Hz 12.5-45mA Shallow base: IP33C Deep base: IP65 CAB492CS/CAB482CS 0.5Hz 12.5-45mA IP21C Catalogue numbers Description Code CASB493 Wall sounder VAD, red, white flash 8500110FULL-0199X CASB483 Wall sounder VAD, red, red flash 8500111FULL-0197X CASB493WP Wall sounder VAD, red, white flash, weatherproof 8500114FULL-0200X CASB483WP Wall sounder VAD, red, red flash, weatherproof 8500115FULL-0201X CAB492WS Wall VAD, red, white flash, shallow base 812033FULL-0209X Description Code CAB492WD Wall VAD, red, white flash, deep base 812034FULL-0210X CAB482WS Wall VAD, red flash, shallow base 812035FULL-0211X CAB482WD Wall VAD, red, red flash, deep base 812036FULL-0212X CAB492CS Ceiling VAD, red, white flash, shallow base 812050FULL-0269X CAB482CS Ceiling VAD, red, red flash, shallow base 812037FULL-0214X EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 31 Addressable fire systems Devices - beam detectors Beam detectors, typically used in large open areas, such as airports, shopping centres and warehouses 32 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Intelligent addressable systems Devices - duct probe detector Beam detectors Duct probe mounting kit There are two available loop powered reflective beam detectors in the intelligent addressable range. The MAB50R has a range of up to 50 metres and the MAB100R has a range of up to 100 metres. Neither requires a power supply and are both equipped with a simple set up mode to enable easy and quick alignment during installation. The beam detector is loop powered with one unique address, and has the ability to add address text at the panel. There is a maximum limit of 20 per loop (based on loop loading calculations). The presence of smoke in a ventilation duct is detected by sampling the airflow through the duct via two sampling tubes. A detector and base are mounted within the sampling chamber, which is located on the external skin of the duct, with sample and exhaust probes passing into the duct in an area of low turbulence. The unit requires an addressable optical detector and base and is supplied with full fixing instructions. Addressable reflective beam detector MAB50R / MAB100R Dimensions H (mm) 210 W(mm) 130 D (mm) 120 Duct probe unit MDP201 HD Typical applications: Large open areas such as warehouses, manufacturing plants, shopping centres, airports etc. W Allows access to the automatic gain control data from the detector. The beam detector will show fire, fault and pre-alarm. Typical applications: Detecting presence of smoke in ventilation ducts. Requires base and detector to be ordered separately. Duct probe unit shown with optical detector fitted Features MAB50R Operating range 5 to 50 metres Tolerance to beam misalignment Detector ± 0.8°, at 35% Prism ± 5.0° Fire alarm thresholds 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) Optical wavelength 880nm Ingress protection IP40 MAB100R 50 to 100 metres Detector ± 0.8°, Prism ± 5.0° 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 880nm IP40 Features Duct width range Duct air speed range Temperature range Optical wavelength Ingress protection 300mm to 1500mm 5 to 50 metres 1m/s to 20m/s Detector ± 0.8° Prism ± 5.0° -20°C or +60°C 880nm IP67 Beam detectors have 3 operating modes: Prism targeting mode designed to provide simple initial alignment of beam and reflector assembly. Alignment mode enables accurate fine tuning of beam alignment without the need for additional calibration equipment or a second operator. Normal running mode during standard operation. Catalogue numbers Description Code MAB50R Reflective beam detector (50m range) 400030FIRE-0067X MAB100R Reflective beam detector (100m range) 400031FIRE-0071X Mounting bracket MRBFP Spare reflector MABR Duct probe unit MDP201 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 33 Intelligent addressable systems Devices - interfaces Interfaces We supply an extensive range of interfaces to support our control panels. Interfaces allow for a wide variety of installations to be simplified without the use of specialist or customised equipment. For assistance deciding which interfaces will benefit you the most, contact our technical support team at firetechsupport@eaton.com Zone monitor unit CZMU352 Spur isolator unit CSI350 Shop monitor unit MSU840 3 channel I/O unit CIO351 Typical applications: The unit connects a zone of suitable conventional detectors (20 detectors per zone) and a separate zone of conventional callpoints (if required) to an addressable panel. It allows for easier connection to existing conventional detection zones, as long as the devices used are compatible. Typical applications: The spur isolator unit enables a spur of intelligent addressable devices to be connected to a main analogue loop. This simplifies the installation of remote parts of buildings or system extensions. The CSI350 doesn't take an address in the number sequence. Recommended no more than a zones worth of devices per isolator. Typical applications: The shop monitor unit is designed to allow small units with conventional fire systems to be fully integrated with a main intelligent addressable fire system. It is ideal for connecting individual shop units into a main shopping centre system. Recommended for use with conventional VADs (see p80). Please note: A PSU (see p38) is required to operate conventional sounder circuits. The MSU840 can have 2 sounder circuits, each with up to 0.3A of power. Typical applications: The 3 channel input/output unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits. Relay contacts are rated at 30V dc 1A. See below for further options. Dimensions 1 H D Description Interface style 1 1 Interface style 2 2 D 2 W H H (mm) 88 129 W (mm) 147 180 W D (mm) 60 60 Catalogue numbers Description Zone monitor unit Shop monitor unit Spur isolator unit 3 channel input/output unit resets on reset (recognised as 1 address) 230V ac relay unit 34 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Code CZMU352 MSU840 CSI350 CIO351 CMIO353 Addressable fire systems Devices - interfaces 230V ac relay unit CMIO353 4 to 20mA interface CGI420 Typical applications: Enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The ability of the output unit to switch 230V ac mains at 8A makes the unit ideal for plant control or mains powered door holders. The input is monitored for open and short circuits therefore can be used for fire input applications such as monitoring sprinkler flow switches. If you require higher current switching (10A) please see page 84 for MAR724. Typical applications: Designed to interface with gas detection modules and are compatible with Eaton intelligent addressable control panels. The supply to the gas detector is taken directly from the interface. Features Ingress protection CZMU352/CSI350/ CMIO353 MSU840/CIO351 IP40 IP65 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 35 Intelligent addressable systems Devices - interfaces Interfaces continued 4 way sounder controller unit CSC354CPR Typical applications: The 4 way sounder controller unit (CSC354CPR) adds functionality to your addressable panel by powering up to 4 lines of conventional output devices. The CSC354CPR gives access to Eaton's extensive range of conventional devices, including EN54-23 certified VADs, beacons, signboards, bells and sounders. It is ideal in situations where there is a requirement for devices with a high current draw or where conventional sounder circuits are in a remote location away from the fire alarm control panel. Dimensions Description 4 way sounder controller Unit H (mm) 300 W (mm) 300 D (mm) 74 Catalogue numbers Description 4 way sounder controller unit Code CSC354CPR Mimic relay boards CIOP4 / CIOP8 Typical applications: These addressable mimic relay boards (CIOP4) and (CIOP8) are 4 and 8 way soft addressing output modules, incorporating integral short circuit isolators. The units are suitable for switching low voltage (24V dc at 1A maximum), via a set of latching relay contacts. The flexibility of these modules is further enhanced by the fact that each output can be programmed for a range of triggers such as disablement, fault, fire, test panel, test zone prealarm, fire routing equipment, fire protecting equipment and reset with up to 16 different trigger sources per output. These units have an additional 4 inputs which can initiate a reset, silence, evacuate and test function. Dimensions Description CIOP4/8 mimic relay board H (mm) 180 W (mm) 244 D (mm) 63 Features Ingress protection CSC354CPR IP30 CIOP4/CIOP8 IP65 D H W Mimic relay Catalogue numbers Description 4 way mimic relay board, 4 inputs, 4 outputs 8 way mimic relay board, 8 inputs, 8 outputs 4 to 20mA interface Code CIOP4 CIOP8 CGI420 36 EATON - FIRE ASYNSDTVEOMISCEAANLDADREMVSICYESSTECMFS-CC2F-5C5C625A5u6guJsutn2e0219017 Fan controller unit JFC6 and JFC18 Intelligent addressable systems Devices - interfaces Typical applications: JFC18 and JFC6 fan controller units work in conjunction with the Eaton's range of intelligent addressable control panels, providing the capability to control and display the status of AHU fans. The units are connected to the control panel by means of the comms loop, utilizing only one address whilst providing the ability to monitor and control up to 18/6 AHU fans. Each JFC18 and JFC6 unit incorporates its own CPU specifically configured to control the relevant input and output logic making programming quick and easy using Eaton site installer software. Recently upgraded to be compatible with new Smoke Management protocols. Both JFC6 and JFC18 are ideal for use in conjunction with updated CF3000 panels and the new MCOM-FC interface module. Dimensions Description JFC6 Fan controller unit (surface mount) JFC18 Fan controller unit (rack mount) H (mm) 125 133 W (mm) 155 482 D (mm) 42 30 H H W D JFC6 Fan controller unit (surface mount) W D JFC18 Fan controller unit (rack mount) Catalogue numbers Description Fan controller unit (surface mount) Fan controller unit (rack mount) Code JFC6 JFC18 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 37 Intelligent addressable systems Devices - micro interfaces Micro interfaces Whereas our standard interfaces are designed to be installed in the position required on the loop, our range of micro interfaces are compact enough to sit within a panels' enclosure, or in our dedicated mini module enclosure (ULBU) which can house up to 3 mini modules. Micro zone monitor unit JIU872 Typical applications: The micro zone monitor unit (JIU872) is suitable for interfacing a zone of up to 20 conventional detectors onto an intelligent addressable control panel. It will operate with any conventional detector in configuration with a schottky diode type base (CDBB300). Micro single channel input unit MJIM Micro single channel output unit MJOM Typical applications: The micro single channel input unit (MJIM) is suitable for monitoring a set of normally open, volt free contacts such as sprinkler system flow switches and auxiliary panel fire/fault signals. Other examples include non-fire input signals such as flow valve open contacts, generator start up, fire door closed etc. Typical applications: The micro single channel output unit (MJOM) is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is also suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc. Variants The MJOM-R gives a 5 second pulse on reset, and is used for connecting/resetting beam detectors. The MJOM-S is identified by the panel as a sounder and does not reset when put into 'silence' mode, only resets once panel has been reset. The MJOM-FC is identified by the panel as sounder and will activate from its associate cause and effect programming. It will reset from a global reset not a global silence command. Suitable for use with fan controller devices for smoke management. Installation into mini module box 1. Fit the unit in position in accordance to the mounting diagram below. 2. Connect the unit according to standard connections. 3. Up to 3 units can be fitted inside a micro module box unit Features Soft addressed Short circuit isolators Single address Ingress protection JIU872 IP40 MJOM IP40 MJIM IP40 180mm FR4 PCB Interface Plate Secured to box with 2 self tapping screws. 60mm 130mm Catalogue numbers Description Code Micro zone monitor unit JIU872 Micro single channel output unit MJOM Micro single channel output unit (sounder) MJOM-S Micro single channel output unit (reset on reset) MJOM-R Micro single channel output unit (fan controller output unit) MJOM-FC Micro single channel input unit MJIM Mini module box unit (empty box) ULBU 38 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Intelligent addressable systems Devices - network interfaces Network interfaces Eaton offer multiple network interfaces which allow our panels and devices a wider variety of functionality. These network interfaces allow the connection of the Eaton network system to a computer network, and PC based applications such as site monitor, site graphic and web server. Lon to RS232 adaptor EC0232 Dual-channel LonWorks TCP/IP interface BMS interface EC400 EC200 Lon network booster EC540 Typical applications: Typical applications: Typical applications: Typical applications: The EC0232 Lon to RS232 The EC200 dual-channel The EC400 is a high performance, The Lon network booster (EC540) adapter allows connection of LonWorks BMS interface is an reliable and secure network is the solution to interconnect our system network (LonWorks) "add-on" to the network which infrastructure device for accessing multiple EIA-709 channels. devices to PC based applications such as site monitor, site graphics and web server. In addition to the standard adaptor, Eaton offer 2 variants for use with a HMX PA/VA translates the pre-configured Eaton Lon Network of intelligent network variables to a set of addressable control panels over un-configured network variables intranet or ethernet. wBneMhtiwcSh,ogrckiavndinatgthaef.unllbaecFcbiebosursentdoOttohpaeticfirePoinTsdtehertevvoiceEerPCsm4oo0ain0nn'a1tsgLbIePuisnicltukhpianntcnooe2nl5fwi6gituIhProatuiot na This unit provides up to 5 ports and routes packets between these ports. In spite of its small size the (EC540) provides best class performance and flexibility in use. system - the ECO232PAVA with no handshaking, and the EC0232PAVA3D with a 3 min time delay. LonWorks NODE Control Panel & Network Card Lon-Fiber ADAPTOR CFSFL02 LonWorks LonWorks dedicated management PC. In order to provide the optimal Easy to uLnodner-sFtibanedr diagnosLtoicnWorks router configuration the (EC540) FibrLeEDs alloAwDiAnsPtTaOlleRrs to instaNll OanDdE supports 2 to 5 ports as well as tetrrxoopuuebbrllteekssnhhoooCwooFttliSentFhdgLeg0te2odoealvn.idcedewdNiCitcoheatnowttueroo&tdrlkPCaanredltsrhoweuitt2ecrhompmeoordadetei"n". ganmdo"dcoensf"isgmuraerdt Fibre optic multi-drop link example network diagram Fibre Optic Multi-Drop Link Fibre Fibre Fibre LonWorks Bus LonWorks Bus LonWorks Bus LonWorks Bus CFSFL02 Lon-Fiber ADAPTOR LonWorks NODE Control Panel & Network Card LonWorks NODE Control Panel & Network Card CFSFL02 Lon-Fiber ADAPTOR LonWorks NODE Control Panel & Network Card LonWorks NODE Control Panel & Network Card CFSFL02 Lon-Fiber ADAPTOR LonWorks NODE Control Panel & Network Card LonWorks NODE Control Panel & Network Card CFSFL02 Lon-Fiber ADAPTOR LonWorks NODE Control Panel & Network Card LonWorks NODE Control Panel & Network Card EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 39 Intelligent addressable systems Devices - network interfaces BACnet gateway EC650B Modbus gateway EC700 Single mode Lon to fibre optic adapter CFSFL01 Dual channel Lon to fibre optic adapter CFSFL02 Typical applications: The BACnet gateway (EC650B) is a CEA- 709/BACnet gateway which maps CEA-709 network variables (NVs) to standard BACnet server objects. When ordered with this part code (EC650B), the LonWorks to BACnet address mapping is preloaded and ready for use with the the intelligent addressable CF3000 system interface board. Typical applications: The modbus gateway is part of the InfraLINK range of network infrastructure components from partners. All of the modbus gateways feature a robust hardware platform with high performance CPU and UART for fast communications without loss of data. The LonWorks to modbus address mapping is pre-loaded and ready for use with the CF3000 fire system interface board. Typical applications: The single mode Lon to fiber optic adapter (CFSFL01) allows connection of the system network (LonWorks) devices through optical fibre, and to allow both point to point or multi drop topology. Typical applications: The dual channel Lon to fiber optic adapter (CFSFL02) allows connection of the system network (LonWorks) devices through optical fibre, and to allow both point to point or multi drop topology. Features Ingress protection EC400/EC540 IP40 (IP20 screws) EC700 IP20 Catalogue numbers Description Code Dual-channel lonworks BMS interface (non handshake) EC200 Dual-channel lonworks BMS interface (self configuring for use with EC700) EC200S Lon to RS232 adapter EC0232 Lon to RS232 adapter (For HMX pa/va system - no handshake) EC0232PAVA Lon to RS232 adapter (For HMX pa/va system - 3 min time delay) EC0232PAVA3D Description TCP/IP interface Lon network booster Bacnet gateway Modbus gateway Single mode lon to fibre optic adaptor Dual channel lon to fibre optic adaptor 40 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Code EC400 EC540 EC650B EC700 CFSFL01 CFSFL02 Intelligent addressable systems Devices - ancillaries Ancillaries A range of ancillaries are available to complement and extend the capability of our existing hardware. Loop splitter unit ZPCB2222 Mimic PCB ZPCB2252-MML / ZPCB2252-MSL SPS Range SPS-2423 SPS-2433 SPS-2453 Typical applications: Allows expansion of the FX6000 intelligent addressable panel from 4 to 16 loops. This interface is mainly applicable in countries where the mixing of detectors, sounders, callpoints and interfaces are not permissible on the same loop or the number of devices per loop is limited to a small number. Typical applications: Up to 250 outputs can be connected to the mimic PCBs (ZPCB2252-MML) and (ZPCB2252-MSL). This offers more capability to the extensive options already offered by the FX6000 control panel. These boards are typical used for geographical LED mimic displays. Typical applications: Offers a compact, robust and versatile power solution to installers, allowing them to safely power fire detection and signaling systems in small to large installations. Compact and discrete design allows for these SPS to be installed in a visible location such as a hotel lobby for instance. Features Ingress protection SPS-2423/SPS-2433/SPS-2453 IP30 Catalogue numbers Description Loop splitter unit Loop Mimic LED PCB (Master) Loop Mimic LED PCB (Slave) Loop Mimic Relay PCB (Master) Loop Mimic Relay PCB (Slave) Safety power supply 24V / 1.5A (batteries not supplied) Safety power supply 24V / 2.5A (batteries not supplied) Safety power supply 24V / 4.5A (batteries not supplied) Code ZPCB2222 ZPCB2252-MML ZPCB2252-MSL ZPCB2252-MMR ZPCB2252-MSR SPS-2423 SPS-2433 SPS-2453 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 41 42 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Intelligent addressable systems Devices - software and testing equipment Software Eaton offer a number of specialised programs to aid with the installation, maintenance, functionality and servicing of our addressable systems. Installed using the USB analogue systems panel interface (see p44) and a PC or laptop, these software programs help to solidify our addressable systems' capabilities and make it easier for users to control and organise the system on their site. Graphical visualisation Site monitor software SITEMONITOR EFGVS Catalogue numbers Description Code Graphical Visualisation Software license 1-2 panels including an EC0232 interface EFGVS1-2 Graphical Visualisation Software license up to 6 panels including an EC0232 interface EFGVS3-6 Graphical Visualisation Software license up to 10 panels including an EC0232 interface EFGVS7-10 Graphical Visualisation Software license above 10 panels including an EC0232 interface EFGVS11-PLUS Graphical Visualisation Software license up to 10 panels with TCP/IP interlink EFGVS7-10-TCPIP Graphical Visualisation Software license above 10 panels with TCP/IP interlink EFGVS11-PLUS-TCPIP Graphical Visualisation Designer Software license - no panel connectivity EFGVS-DESIGN Typical applications: Eaton Fire Graphic Visualisation Software (EFGVS) is a state of the art and powerful supervision management tool for Eaton Fire addressable systems. Users can monitor, visualise in 2D and 3D, control and interrogate their systems to ensure alarms are located quickly and dealt with efficiently. Ergonomic and intuitive, EFGVS includes a comprehensive list of advanced features offering the system designer and site supervisor a very efficient tool ensuring all information and controls be available at their fingertips. Typical applications: Site monitor / webserver software is designed to monitor Eaton fire systems and allow quick PC based administration. Using a simple interface, authorised users can view control panel event history, event status, device properties and other information depending on access permissions defined by the system administrator. Description Code Graphical Visualisation Premium Designer Software license including an EC0232 interface EFGVS-PREMIUMDESGN Interface to connect panel network (LONWorks) to PC (RS232) EC0322 Site monitor / webserver software EF-SITEMONITOR All software products except SITEMONITOR include EC0232 (p36) as standard EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 43 Intelligent addressable systems Devices - software and testing equipment Testing equipment As well as offering complete fire systems, Eaton can also provide testing equipment to ease the process of installation, commissioning, maintenance and fault finding. Loop tester kit LP800KIT USB analogue systems Addressable device panel interface programmer USBINT2 CF800PROG Typical applications: The loop tester kit is a hardware/ software combination that can be used to test, commission and fault find a loop of up to 200 intelligent addressable devices (sensors, sounders, ancillary devices) without having to connect the loop to the intelligent addressable control panel. The loop tester is connected between the loop and PC, and allows the engineer to quickly identify and locate any loop device that is operating outside its operating conditions. Typical applications: The analogue systems panel interface is a universal serial bus converter that provides conversions from RS232 to USB, TTL to USB or TTL to RS232. These options provide the connectivity required between a PC and intelligent addressable control panels, wireless control panels, and wireless survey tools including our range of software solutions (see page 43). Typical applications: The addressable device programmer is a versatile tool to aid the installation, commissioning, maintenance and servicing of current intelligent addressable devices and fire systems. This unit is light, robust and easy to operate using a user friendly menu structure on 2 x 40 character LCD display. It is powered from a single PP3 size, heavy duty battery or an external supply. CF800PROG can: Program sensor modes (see p24). Change address details Change heat detector settings Read analogue levels Catalogue numbers Description Loop tester kit Addressable device programmer USB panel interface Code LP800KIT CF800PROG USBINT2 44 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Notes EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 45 UL intelligent addressable systems Product Name UL Systems Underwriters Laboratories Inc. (UL) is an independent product safety certification organisation, established in 1894, to develop standards and test procedures for products, materials, components, assemblies, tools and equipment. Chiefly dealing with product safety it also evaluates and certifies the efficiency of a company's business processes through its magnificent system registration programs. Since the launch of our UL Listed fire product range, several prestigious projects worldwide have been supplied including Hyatt Resort and Spa, Shangri-la at the Fort and Times Square projects in South East Asia and several major projects in the Middle East including a major projects within the prestigious Riyadh Financial District in the Kingdom of Saudi Arabia. The Eaton UL range is designed to provide a solution for all sizes of project, from the simple small stand alone system to the large multi panel networked system with PA/VA and BMS integration. 46 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 UL intelligent addressable systems Contents Contents UL listed fire systems range Panels ULFX6000 series panels 48 Devices Addressable sensors 50 Conventional detectors 52 Horns and strobes 54 Pull stations 56 Interfaces 58 Micro interfaces 59 SIGNALING 4AC5 FIRE ALARM EQUIPMENT EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 47 UL intelligent addressable systems ULFX6000 series ULFX6000 series UL listed control panels ULFX6000RM (wall mount red metal) ULFX6000 (wall mount graphite) The ULFX6000 series panels are UL listed, high specification, wall or rack mounted fire panels. Combining sophisticated functionality with simple operation and aesthetically pleasing design, the panels are available in a number of loop configurations. Each panel is networkable with up to 126 other Eaton UL fire panels. The control panel has the ability to support complex cause and effect programming. A wide range of user controllable functions make the system ideal for a diverse range of projects, from industrial applications through to large multi-site commercial developments. Benefits · Soft addressing · Large versatile touchscreen user interface · Integral printer (optional) · Integral battery and power supply · 2 x 12Ah batteries included · Flexible distributed network capability · Full range of compatible devices · 4 notification appliance circuits (NACs) outputs · 2 or 4 class A style 7 SLC loops SIGNALING · PAS (Positive Alarm Sequence) 48 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 4AC5 FIRE ALARM EQUIPMENT Dimensions D2 W H D2 W H UL intelligent addressable systems ULFX6000 series Description ULFX6000 ULFX6000RM D1 H (mm) 397 398 W (mm) 497 505 D1 (mm) 75 48 D1 D2 (mm) 130 118 Compatible repeater panels The ULFX6000 has both a standard and a touchscreen repeater panel available. Ideal for larger sites, the repeater allows you to display the system information from multiple locations. Features Active or passive option No programming required Multi language capability Allows networking with other Eaton fire panels Integral power supply Ingress protection *Except local text information ULFX6000PR * IP30 ULFPTR6000 IP40 Catalogue numbers Description 2 loop panel 4 loop panel 2 loop panel, integral printer 4 loop panel, integral printer 2 loop panel, network card 4 loop panel, network card 2 loop panel, integral printer, network card 4 loop panel, integral printer, network card Code ULFX60002G ULFX60004G ULFX60002GP ULFX60004GP ULFX60002GNC ULFX60004GNC ULFX60002GPNC ULFX60004GPNC Description 2 loop panel, network card, red metal box 4 loop panel, network card, red metal box Rack mounted 2 loop panel Rack mounted 4 loop panel Rack mounted 2 loop panel c/w network card Rack mounted 4 loop panel c/w network card Loop connected passive repeater panel Touchscreen network repeater panel Code ULFX60002NCRM ULFX60004NCRM ULFXR6000L2 ULFXR6000L4 ULFXR6000L2NC ULFXR6000L4NC ULFX6000PR ULFPTR6000 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 49 UL intelligent addressable systems Devices - addressable sensors Sensors Our UL range has multiple options for intelligent addressable sensors. All sensors are designed for optimum functionality in mid-large sized builds. They are all soft addressed and have integral short circuit isolators. Addressable sensor base UCAB300 Optical smoke sensor Photo-thermal sensor Heat sensor ULFX320 ULFX340 ULFX330 Typical applications: Specifically designed for use with all of our UL addressable sensors, the UCAB base will be used in all builds. Typical applications: Suitable for most applications. Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. Typical applications: Responds quickly to fast clean burning fires. Maintains the advantage of optical sensors when detecting smouldering fires. Typical applications: Environments where the ambient conditions might cause false alarms with smoke detectors. Examples include areas with high levels of dust or fumes. Sensor detail Addressable base detail 50 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 SIGNALING 4AC5 UL intelligent addressable systems Devices - addressable sensors Performance Heat Class ULFX320 Heat element rating N/A Heat detector spacing N/A Heat class N/A ULFX340 135°F 50ft (heat alone operation) A2S ULFX330 ROR + Fixed 135°F, Fixed 135°, Fixed 194°F 50ft A2R Dimensions Dia D1 D2 Description Optical Photo-thermal Heat Diameter (mm) Depth (mm) (incl base) (excl base) 104 33 104 43 104 43 Depth (mm) (incl base) 45 55 55 Features Ingress protection ULFX320 IP30 ULFX340 IP30 ULFX330 IP30 Catalogue numbers Description ULFX320 Optical smoke sensor ULFX340 Photo-thermal sensor ULFX330 Heat sensor Addressable sensor base Addressable sounder base Code 400005FIRE-0017X 400006FIRE-0018X 400007FIRE-0019X UCAB300 ULFXN538LBS EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 51 UL intelligent addressable systems Devices - conventional detectors Detectors Our UL range has multiple options for conventional detectors. All detectors have a removable detector chamber and drift compensation. The range of detectors for different applications allow for all build requirements to be met. As there is no UL certified conventional panel a ULMIU872 micro interface (p59) is required in conjunction with a UL intelligent addressable panel to use conventional detectors. Optical smoke detector UCPD-2W Photo-thermal detector UCPT-2W Fixed heat detector (135°F) UCHT-2W Typical applications: Suitable for most applications. Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. Typical applications: Responds quickly to fast clean burning fires. Maintains the advantage of optical sensors when detecting smouldering fires. Typical applications: Environments where the ambient conditions might cause false alarms with smoke detectors. Examples include areas with high levels of dust or fumes. Performance Heat class Heat element rating Heat detector spacing Mounting position UCPD-2W UCPT-2W UCHT-2W N/A 135°F 135°F N/A 50ft (heat alone 50ft operation) Ceiling in open Ceiling in open Ceiling in open areas areas areas Features Ingress protection UCPD-2W IP40 UCPT-2W IP40 UCHT-2W IP40 52 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 SIGNALING 4AC5 UL intelligent addressable systems Devices - conventional detectors Conventional detector base CB2E Typical applications: The CB2E has been specifically designed for compatibility with our UL range of conventional detectors. It can be be used in all builds with conventional detectors. Dimensions Dia D1 D2 Catalogue numbers Description 2 wire detector, optical 2 wire detector, opto-heat 2 wire detector, fixed heat 135°f Standard detector base Code UCPD-2W UCPT-2W UCHT-2W CB2E Description Optical Photo-thermal Heat Diameter (mm) (incl base) 104 104 104 Depth (mm) (incl base) 45 55 55 Depth (mm) (excl base) 33 43 43 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 53 UL intelligent addressable systems Devices - horns and strobes Horns and strobes Our UL range incorporates a variety of audio and visual notification devices. Each device has up to 48% savings in current draw compared to similar products. The whole range is easy to install and has voltage test points for quick troubleshooting and easy spot checking, saving time on both installation and maintenance. Wall mount horn HNR Ceiling mount horn HNWC Wall mount horn strobe/synchronised strobe HSR/STR Ceiling mount horn strobe/synchronised strobe HSWC/STWC Typical applications: The horns are ideal for retrofit jobs, limited space environments and pre-existing wire configurations. Typical applications: The horns are ideal for retrofit jobs, limited space environments and pre-existing wire configurations. Typical applications: With the range of settings for both audio and visual purposes, these products are effectively 9 models in 1 appliance. With this functionality, and both ceiling and wall mount options available, it will meet almost any build requirements. The synchronised option enhances both the sound and light output by keeping the outputs of multiple devices in sync. Dimensions W W D D Dia D H Description Wall mount horn HNR Wall mount horn strobe/ synchronised strobe HSR/STR H (mm) 133 131 W (mm) 116 131 D (mm) 56 110 Description Ceiling mount horn HNWC Ceiling mount horn/ synchronised strobe HSWC Diameter (mm) 166 Depth (mm) 34 166 34 54 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 SIGNALING 4AC5 UL intelligent addressable systems Devices - horns and strobes Wall mount outdoor synchronised strobe RSSWP-2475W-FR Ceiling mount outdoor synchronised strobe RSSWP-2475C-FW Typical applications: The outdoor synchronised strobes are UL certified to meet adverse weather conditions. They are perfect for builds where outdoor indication is required. These units use a universal, common mounting base making them ideal for retrofit jobs, limited space environments and pre-existing wire configurations. Dimensions W D H Description H (mm) RSSWP* 131 *Both wall mount and ceiling mount variants W (mm) 131 D (mm) 110 Catalogue Numbers Description Code HNR Wall mount horn HNR HNWC Ceiling mount horn CN128972 HSR Wall mount horn strobe HSR HSWC Ceiling mount horn strobe CN127464 STR Wall mount synchronised strobe STR STWC Ceiling mounted synchronised strobe CN127488 RSSWP-2475W-FR Wall mount outdoor synchronised strobe CN129013 RSSWP-2475C-FW Ceiling mount outdoor synchronised strobe CN124446 WPSBB -R Exposed conduit, surface mount back box (RED) CN109751 WPSBB-R + WP-KIT Concealed conduit surface CN109751 + CN104486 mount back box (RED) EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 55 UL intelligent addressable systems Devices - pull stations Pull stations The addressable pull stations are constructed of high quality, die cast metal for long lasting performance. The range consists of the UL listed MPS range of pull stations and the UL listed fast response input initiating module (ULMCIM-C). Single action addressable pull station UMPS-100/ UMPS-100WP Single action conventional pull station SG42BK2 Typical applications: Indoor/weatherproof pull station for use with addressable systems (UMPS-100/UMPS-100WP). A dual action model is also available (UMPS-200, not shown), where the push bar rotates inward allowing the pull handle to be grasped in a one handed motion. Typical applications: Cost effective conventional version of the single action pull station, must be used in conjunction with ULMIU872. Back box ordered seperately. Pull station detail Dimensions D H W H (mm) 118 W (mm) D (mm) 80 80 Catalogue numbers Description Single action pull station, supplied with back box (addressable) Weatherpoof single action pull station Double action pull station Weatherproof double action pull station ULMIU872 Micro zone monitor unit ULMCIM-C micron single channel input unit (call point) Conventional single action pull station (back box ordered seperately) Conventional double action pull station (back box ordered seperately) Indoor back box for conventional, surface mounting Weatherproof back box for conventional, weatherproof Code UMPS-100 UMPS-100WP UMPS-200 UMPS-200WP 400025FIRE-0054X 400014FIRE-0057X SG42BK2 SG42BK1 SGB32S SGB-32C 56 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 SIGNALING 4AC5 UL intelligent addressable systems Product Name EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 57 UL intelligent addressable systems Devices - interfaces Interfaces We supply an extensive range of interfaces to support our UL control panels. Interfaces allow for a wide variety of installations to be simplified without the use of specialist or customised equipment. For assistance deciding which interfaces will benefit you the most, contact our technical support team; firetechsupport@eaton.com 4 Way Sounder Controller Unit ULCSC354 Shop monitor unit ULCSUM355 Spur isolator unit ULCSI350 3 channel I/O unit ULCIO351 Typical applications: The unit connects 4 lines of conventional output devices on a single address to an addressable panel. Ideal for when specialist devices with a high current draw are required, such as Eaton's UL ceiling and wall horns/strobes. Or where conventional sounder circuits are in a remote location away from the fire alarm control panel. Typical applications: The shop monitor unit is designed to allow small units with conventional fire systems to be fully integrated with a main intelligent addressable fire system. It is ideal for connecting individual shop units into a main shopping centre system. Typical applications: The spur isolator unit enables a spur of intelligent addressable devices to be connected to a main analogue loop. This simplifies the installation of remote parts of buildings or system extensions. Typical applications: The 3 channel input/output unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits. 230V ac relay unit Dimensions ULCMIO353 D D H H Typical applications: Enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The ability of the output unit to switch mains also makes the unit ideal for plant control or mains powered door holders. The input is monitored for open and short circuits so can be used for fire input applications such as monitoring sprinkler flow switches. W W Description Interface units 4 way sounder controller unit H (mm) 129 300 W (mm) D (mm) 180 60 300 74 Features Ingress protection ULCSC354 IP30 ULCSUM355 /ULCSI350/ ULCIO351/ULCMIO353 IP40 58 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 SIGNALING 4AC5 UL intelligent addressable systems Devices - micro interfaces Micro interfaces Whilst our standard UL interfaces are designed to be installed in the position required on the loop, our range of micro interfaces can sit within a panels' enclosure. Micro single channel Micro single channel output units input units ULMCOM/ULMCOM-S ULMCIM/ULMCIM-C Micro zone monitor unit ULMIU872 Dimensions D W H Typical applications: The Micro Single Channel Output Unit (ULMCOM) is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is also suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc. The ULMCOM-S is identified by the panel as a sounder. Typical applications: The Micro Single Channel Input Unit (ULMCIM) is suitable for monitoring a set of normally open, volt free contacts such as sprinkler system flow switches and auxiliary panel fire/fault signals. Other examples include non-fire input signals such as flow valve open contacts, generator start up, fire door closed etc. The ULMCIM-C is identified by the panel as a call point and is designed for use with pull stations. Typical applications: The Micro Zone Monitor Unit (ULMIU872) is suitable for monitoring a zone of up to 20 UL approved conventional detectors. H (mm) 65 W (mm) D (mm) 35 18.5 We offer an enclosure for our micro interfaces, see p38. Features Ingress protection ULMCOM/ ULMCOM-S IP40 ULMCIM/ ULMCIM-C IP40 ULMIU872 IP40 ULMIU872 IP40 ULBU IP40 Catalogue numbers Description 4-Way sounder controller unit Shop monitor unit Spur isolator unit 3 Channel input/output unit resets on reset 120V/230V ac relay unit ULMIU872 Micro zone monitor unit SIGNALING 4AC5 Code ULCSC354 ULCSUM355 ULCSI350 ULCIO351 ULCMIO353 400025FIRE-0054X Description ULMCOM Micro single channel output unit (recognised as output unit) ULMCOM-S Micro single channel output unit (recognised as sounder) ULMCIM Micro single channel input unit (recognised as input unit) ULMCIM-C Micro single channel input unit (recognised as callpoint) Mini module box unit (empty box) Code 400015FIRE-0060X 400016FIRE-0063X 400013FIRE-0051X 400014FIRE-0057X ULBU EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 59 60 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Contents Conventional fire systems Conventional fire system panels EFCV8 series panel 62 FXP2200 series panel Conventional systems Contents 64 CF5000 series panel 66 EFCDP series panel 68 Conventional devices Detectors and indicators 70 Bases 74 Beam detectors 72 Duct probe detector 75 Callpoints 76 Bells 77 Sounders 78 Visual alarm devices 80 Indicators 82 Sounder indicators 83 Door retainers 84 Auxiliary power supply 85 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 61 Conventional systems EFCV series EFCV8Z Conventional control panel Eaton's 8 zone conventional fire system panel delivers a straightforward, intuituve interface that makes programming and maintenance simple. Approved to EN54-2&4, it offers a comprehensive set of functionalities in a modern, robust and discrete enclosure. It's appearance and performance makes the panel well suited for life safety notification in a wide variety of small to medium sized buildings, particularly schools, warehouses, retail stores and office buildings. With the addition of an isolator barrier the panel has the additional flexibility to monitor standard or EFCV8ZONE No. of zones Detectors per zone Maximum loading per zone Repeater Port No. of sounder circuits Maximum loading per sounder circuit Ingress protection 8 32 32mA 4 250mA IP30 intrinsically safe conventional zone circuits, making it suitable for industrial applications. Benefits · Zones switchable between standard conventional and intrinsically safe zones (using isolator barrier) · One man test facility · Class change input · Interlink relay functionality for connecting 2 panels together · Interlink relay allows for greater system flexibility · Supports an expansion card for Fire Routing Equipment, Fire Protection Equipment and fire relays per zone · Modern and discreet enclosure 62 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Conventional systems EFCVSeries Dimensions Catalogue numbers Description Eaton 8 Zone Conventional Panel End of Line Module Code EFCV8Z EOLM-1 Complete Panel Back Box H (mm) 336 273 W (mm) 375 338 D (mm) 134 88 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 63 Conventional systems FX2200 series FX2200CPD series Conventional control panel "A flexible conventional solution that ensures ease of use and high reliability" The FX2200CPD range of conventional control panels provide a solution to any conventional system requirement. The advanced features include a simple "one-shot" user test facility, class change contacts, battery voltage alarms and charger temperature compensation, all included as standard to ensure ease of use and high reliability. Attention to detail is emphasised by the neat log book holder feature, allowing essential records to be stored close to hand, ready for quick reference. For larger installations, custom configuration of the panels offers even greater flexibility, allowing project specific requirements to be easily met, in a competitive and cost effective package. Benefits · Compact design · Surface or semi-flush mounting · Numerical access code (no lost keys) · 2 or 4 zones panels · Flexible, high specification system · Simple "one-shot" auto-reset user test facility · Maintenance free poly switch circuit protection, with auto reset No. of zones Detectors per zone No. of alarm circuits FX2202 2 32 2 FX2204 4 32 2 Ingress protection FX2202 IP30 FX2204 IP30 64 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Compatible Repeater Panel To complement the FX2200 range a repeater panel is available for connection to the 4 zone control panel. Specifically designed for ease of installation, it requires only 2 interconnecting wires from the main panel, saving material cost and labour time. Further repeater panels can be cascaded which does not affect standby time as each has its own mains supply and standby battery. The repeater displays all the same functions as the main panel and includes an indicator test facility. Conventional systems FX2200 series Features · Charger with built in temperature compensation · Displays essential information at other key locations in a large building/site · Zone fire and fault conditions · Test mode in operation · Zones or alarm lines in disabled mode Dimensions D1 W H MUTE SCROLL BUZZER 1 23 4 5 Catalogue numbers Description Conventional 2 Zone Panel Conventional 4 Zone Panel Fire Alarm System Log Book Code FX2202CPD FX2204CPD MFALOG D2 H (mm) W (mm) D1 (mm) D2 (mm) 2 / 4 zone panel 270 332 45 47 Cut-out 265 327 - - Note: If surface mounting add D1 and D2 to obtain depth dimension EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 65 Conventional systems CF5000 series CF5000 series Conventional control panel "Contemporary and compact panel design that provides a solution to any conventional system requirement" The new CF5000 conventional control panel is currently available in a 16 zone version. The panel features an array of user friendly features and are available at very competitive prices. The attractive flush or surface mountable plastic enclosure, with metal back box, has been designed through intensive voice of the customer research to provide ample space for termination of cables. Benefits · Zonal relay card as standard · One man test facility · Non latching zone feature · Class change input · Fire and fault relays · Discreet enclosure · Supplied complete with battery for 24 hour standby No. of zones Detectors per zone No. of alarm circuits Zonal relay card Ingress protection CF50016 16 30 4 IP30 66 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 ION CERTIFI LPCB SS PREVENT CATIO N BOA RD LO Conventional systems CF5000 series Dimensions D1 H1 W2 D2 H2 W1 Description H1 (mm) Total height 16 Zone 276 W1 (mm) Total width 375 D1 (mm) Total depth 136 H2 (mm) Back box height 232 W2 (mm) D2 (mm) Back box width 335 Back box depth 96 Catalogue numbers Description 16 zone control panel Fire alarm system log book Code CF50016 MFALOG EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 67 Conventional systems EFCDP series EFCDP NEW PRODUCT The Eaton Fire EFCDP EN54 compliant conventional panel series is designed to provide simplicity and reliability to end users. Available with 2, 4 or 8 zones, this easy to install panel provides ease of access through its spacious interior ensuring plenty of room for wiring and battery change. It comes with a 1.25 Amp 27V power supply and includes space for 2 x 3.2 Ah sealed lead acid batteries. Battery management is fully monitored through the system. Fire and fault voltage-free relays and a class change input are included. Activation of the panel is carried out via access code. The panel features soft tactile colour coded buttons to facilitate control and programing, and is easily tested through one man walk tests reducing maintenance costs for the end-user. The panel is compliant with European standards EN54-2 & 4, Fire Detection and Alarm Systems - Control & Indicating Equipment, and carries an LPCB mark. Benefits · Easy to install and maintain · One-man test facility · Compatible with Eaton D200 detector series · Up to 30 detection devices per zone · Secured with code entry for activation of controls · Test with or without sounders in test mode · Ease of programming with colour coded, soft tactile buttons · Modern and compact enclosure EFCDP EFCDP No. of zones Detectors per zone Power supply Monitored sounder outputs 2, 4, 8; EOLR = 6K8 30 Switch mode 1.25A/27Vdc 2 Alarm load Cable entry Max battery size Compliance 68 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 800mA (shared) 13 entries, 20mm diameter knockouts 2 x 3.2Ah, 12V, SLA EN54 Parts 2 and 4 ION CERTIFI LPCB SS PREVENT CATIO N BOA RD LO Conventional systems EFCDP series Dimensions Catalogue numbers Description EFCDP Conventional Detection Panel 2 zones EFCDP Conventional Detection Panel 4 zones EFCDP Conventional Detection Panel 8 zones Code EFCDP2Z EFCDP4Z EFCDP8Z H (mm) Back Box 235 Lid 235 Total depth (back box + lid fitted) W (mm) 287 285 D (mm) 60 20 80 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 69 Conventional systems Devices - detectors and remote indicator Detectors and remote indicator The conventional range offers a multi-mode, 5 in 1 detector (FXN922), covering many building needs. It's quick and simple to install with a stylish low profile design. The detector is mounted on our standard conventional base (EFXN520) but can also be used in conjunction with our relay base (FXN520R) for local switching. Each detector is fitted with a 360° viewable LED for indication. This multi-mode detector can be configured to operate as either an optical detector, photo-thermal detector or 1 of 3 heat detector modes (A1R, BS, CS) using the four position switches located at the back of the detector. The FXN922 is certified for use in all 5 modes. Compatible with panels EFCV8, FXP2200, CF5000. Multimode detector FXN922 Base not included. See p74 for compatible bases. Optical smoke detector mode Typical applications: Suitable for most applications. Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. Photo-thermal detector mode Typical applications: Responds quickly to fast clean burning fires. Maintains the advantage of optical sensors when detecting smouldering fires. Rate of rise heat detector mode Typical applications: Environments where the ambient conditions might cause false alarms with smoke detectors. Examples include areas with high levels of dust or fumes. Fixed heat detector (77°) mode Typical applications: Environments where a change in temperature is a likely occurrence. Using a fixed heat negates false alarms from insignificant temperature rises. Fixed heat detector (92°) mode Typical applications: Environments where the ambient heat levels are likely to be above normal temperatures, such as restaurant kitchens. Note: We can also supply separate detectors for each individual mode if they are required. These are displayed in the catalogue numbers in the table over the page. Remote indicator FX251D Dimensions D Typical applications: The remote indicator is ideal for applications such as void spaces or outside locked or inaccessible rooms to provide indication of the activation of an automatic detector. H W Description Remote indicator H (mm) 87 W (mm) 87 D (mm) 49 70 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 ION CERTIFI LPCB SS PREVENT CATIO N BOA RD LO Conventional systems Devices - detectors and remote indicators Performance Feature Area coverage (subject to local standards) Heat class Alarm temperature Optical Photo-thermal Rate of rise smoke mode mode mode 100m2 100m2 50m2 Fixed heat 77 °C mode 50m2 Fixed heat 92 °C mode 50m2 N/A A2S N/A 60 °C A1R 60 °C BS 77 °C CS 92 °C Dimensions Dia Switch settings D1 D2 On On Description Diameter (mm) Depth (mm) Depth (mm) (incl base) (incl base) (excl base) Multimode detector* 104 42 55 Optical smoke 104 detector 33 45 * All other conventional detectors share same dimensions 12 34 Off Description Optical mode Photo-thermal mode Rate of rise mode Fixed heat 77° mode Fixed heat 92° mode Ingress protection SW1 - SW2 OFF OFF ON OFF ON SW3 OFF OFF OFF OFF ON SW4 OFF ON OFF ON OFF 5 in 1/EFXN533/ FX251D/CIR301WP EFXN632\EFXN525/ EFXN524\EFXN526 IP40 IP30 Catalogue numbers Description 5 in 1 Multi-Mode Detector FXN922 Optical Smoke Detector Photo-Thermal Detector Rate of Rise Heat Detector Fixed Heat Detector 77 °C Fixed Heat Detector 92 °C Remote Indicator Weatherproof Remote Indicator Code 400017FIRE-0031X EFXN533 EFXN533 EFXN525 EFXN524 EFXN526 FX251D CIR301WP EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 71 Conventional systems Devices - conventional detectors Detectors for EFCDP panel range The D200 conventional detector range offers a multipurpose offering for both smoke and heat detection. The range includes optical, heat and multi-sensor detectors suitable for applications within two-wire conventional systems and addressable systems suitable for conventional detectors. The detectors provide fire detection and alarm system designers with a standard compliant economical product for life safety and property protection. Optical smoke detector D200-O Multi-sensor detector D200-HO Heat detector D200-H Typical applications: Suitable for most applications. Early detection of fire and high immunity against unwanted alarms. Typical applications: Ideal for both fast-flaming and slow smouldering fires. Dual purpose detector to detect smoke, heat or a combination, supported by high immunity against unwanted alarms Typical applications: Environments where the ambient conditions might cause false alarms with smoke detectors. Examples include areas with high levels of dust or fumes. Performance Alarm current (max) Alarm response threshold (smoke) Alarm response threshold (heat) D200-O 40mA N/A N/A Dimensions D200-HO D200-H 50mA 0.08 - 0.15 dB/m 590c static and rate of rise 50mA 0.08 - 0.15 dB/m 590c static and rate of rise Dimensions (mm) excluding contacts Catalogue numbers Description Order code D200-HO two-wire multi-sensor detector 400020FIRE-0034X D200-O two-wire optical smoke detector 400019FIRE-0033X D200-H two-wire heat detector 400018FIRE-0032X Note: products must be ordered in multiples of 8 pcs 72 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 D200-O 102 x 34 D200-HO 102 x 45 D200-H 99 x 45 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 73 Conventional systems Devices - bases and beam detectors Bases There are two types of conventional detector bases, compatible with our range of detector heads to provide a wide functionality for different applications. The standard base (EFXN520) is a general use product, providing a foundation for our conventional detectors, whereas the relay base (FXN520R) provides a local relay signal in the event of its host detector being triggered, making it ideal for instigating a local response. Note: Bases not compatible with D200 conventional detector range. Standard base EFXN520 Relay base FXN520R Typical applications: General use product, suitable for use in most indoor applications. Typical applications: Areas where a local response is required. Dimensions D D Dia Standard base Description Standard base Relay base Dia (mm) 104 102 Dia Relay base D (mm) 22 40 Catalogue numbers Description Standard base Relay base Code EFXN520 FXN520R 74 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 ION CERTIFI LPCB SS PREVENT CATIO N BOA RD LO Duct probe detector The presence of smoke in a ventilation duct is detected by sampling the airflow through the duct via two sampling tubes. An optical detector and base are mounted within the sampling chamber, which is located on the external skin of the duct, with sample and exhaust probes passing into the duct in an area of low turbulence. Duct probe unit MDP201 Conventional systems Devices - duct probe detector Typical applications: Detecting presence of smoke in ventilation ducts. Duct probe unit shown with optical detector - detector and base must be ordered separately. Features Duct width range Duct air speed range Temperature range Ingress protection Catalogue numbers Description Mounting bracket Duct probe unit 300mm to 1500mm 5 to 50 metres 1m/s to 20m/s Detector ± 0.8° Prism ± 5.0° -20°C or +60°C IP67 Code MRBFP MDP201 Duct probe units can be used to detect the presence of smoke in a ventilation duct EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 75 Conventional systems Devices - callpoints Callpoints Two versions of the conventional callpoint are available, the surface or flush mounted FX201 or the weatherproof FX203. Both have an integral short circuit isolator and are very simple to install. The callpoints are packaged with 2 frangible glass elements and test key, with a comprehensive range of further devices available. Surface/flush mounted Weatherproof callpoint callpoint FX203 FX201 Dimensions W H Typical applications: General use product, suitable for use in most indoor applications. Typical applications: Builds requiring a callpoint in harsh conditions. For example, outside or in a wash down area. D Description Surface mounted Flush mounted Weatherproof H (mm) 87 87 87 W (mm) 87 87 87 D (mm) 57 36 59 Features Fast fit clip Heavy duty terminals Ingress protection FX201 IP42 FX203 IP65 Further accessories: Catalogue Numbers Description Code Surface/flush callpoint FX201 Weatherproof callpoint FX203 CXPC Protective hinged cover (pack of 10) CXPC Spacer plates (pack of 10) MBGSP MBGBEZ Recessing bezels (pack of 10) MBGBEZ MBGREKIT Resettable element kit (pack of 10) MBGREKIT FX5G Spare break glasses (pack of 10) FX5G MFBGKEY3 Callpoint keys (pack of 10) MFBGKEY3 Callpoint shown with protective hinged cover Callpoint recessing bezel 76 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 ION CERTIFI LPCB SS PREVENT CATIO N BOA RD LO Bells Bells still remain a popular choice for many applications where they can sometimes be used as a signal for non-fire purposes, such as class change in a school. Internal 6 inch bell FX006 Conventional systems Devices - bells Typical applications: Can be used for non-fire applications, such as class change in a school. Dimensions D Dia Internal 6 inch bell Description 6 inch internal bell Dia (mm) 152 D (mm) 63 Bells can be used for non fire applications such as class change in a school Sound output Sound Output FX006 93-95dB(A) at 24V dc MWB824 95dB(A) (+/-2) Features Ingress protection FX006 IP21C Catalogue numbers Description FX006 Internal 6 inch bell Code FX006 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 77 Conventional systems Devices - sounders Sounders We have an extensive range of conventional sounders, designed to meet every specification's functional and aesthetic needs. Completely EN54 Pt. 3 certified, each sounder offers a unique solution to your conventional system requirements. Flush sounder FX003 Surface sounder FX002SB Weatherproof surface sounder FX002DB High output wall sounder FX007 Typical applications: Ideal for retail, hotel and residential applications such as sheltered housing. Typical applications: This all-purpose sounder has been designed to be both robust and aesthetically pleasing to meet many build requirements. Typical applications: The weatherproof sounder is perfect for harsh weather conditions where a sounder is needed. With selectable tones a high volume can be easily achieved meaning this sounder functions well in outdoor settings. Typical applications: With a maximum output of 120dB(a), this sounder is ideal for areas with high ambient noise levels like warehouses. Low current wall sounder MLC624 Base mountable sounder FXN824 Typical applications: Designed to provide a high sound output with a low current consumption the MLC624 is perfect for areas where high sound levels need to be achieved but sounder circuit capacity is limited. Typical applications: With a slim and aesthetically pleasing design this base sounder is ideal for applications such as hotel bedrooms where a detector/ sounder or a detector/sounderbeacon is required. Please note a detector base is still required when used in conjunction with a detector 78 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Wall sounder detail Conventional systems Devices - sounders Sound output FX003 FX002 FX007 MLC624 FXN824 Sound output 98dB(a) at 1 Metre 105dB(a) max (+/-2) 120dB(a) (+/-2) 100dB(a) at 24V dc 80/90dB(a) (+/-3) @ (+/-2) at 24V dc Max at 1m (tone 5) 1 Metre 114dB(a) (+/-2) Max at 1m (tone3) Tones 32 32 32 3 8 Dimensions W D D D D Dia H D H Flush sounder W Wall sounder Description Flush sounder High output wall sounder Low current wall sounder Features Ingress protection H (mm) 86 105 105 FX003/ FX003W IP20 W (mm) 86 105 105 D (mm) 36 95 95 FX002SB IP54 FX002DB IP65 Dia Dia Surface sounder Weatherproof surface sounder Description Surface sounder Weatherproof surface sounder Base mountable sounder Dia (mm) 93 93 111 Base mountable sounder D (mm) 63 93 26 Ingress protection FX007 IP42 Catalogue Numbers MLC624 IP30 FXN824 IP65 Description Flush sounder, red Flush sounder, white Low profile surface sounder, red Weatherproof deep base surface sounder back box, red (IP65) High output wall sounder Low current wall sounder Base mountable sounder Blanking plate for FXN824 (pack of 5) Deep base for surface sounder (IP65) Code FX003 FX003W ROLP-R-S ROLP-R-D FX007 650001FULL-0003X FXN824 MDS824COV FX000WP EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 79 Conventional systems Devices - EN54-23 visual alarm devices Visual alarm devices (VADs) From 31st December 2013 a new beacon standard, EN 54-23 became mandatory throughout the EU where Construction Product Regulation (CPR) applies. It directly affects the use of visual alarm devices (VADs) in fire detection and alarm systems for non-domestic premises. Its purpose is to standardise the requirements, test methods and functional criteria of VADs to ensure that their visual performance is measured and presented in a uniform manner. Eaton's LX range has been designed to comply with the new EN 54-23 standard. With current consumption as low as 10mA, the range has been developed to provide the lowest current consumption with the highest possible coverage. Three years in the making, the LX range, available for wall and ceiling applications, features a number of patented technologies including an innovative lens and flash pattern. Solista LX wall FXSOLWRS 1Hz FLASH Typical applications: With both a shallow base and deep base option the Solista meets requirements of a large range of builds. Solista LX ceiling FXSOLCWS 1Hz FLASH Typical applications: The ceiling option Solista helps to cover different types of room sizes to meet the requirements of the CoP 0001 design guidelines. RoLP LX wall FXROLPWR Symphoni LX wall FXSYG1WR Symphoni LX WP wall (weatherproof) FXSYG1WR-WP These products are all red flash, for more options please contact: firetechsupport@eaton.com 1Hz FLASH 1Hz FLASH 1Hz FLASH Typical applications: The RoLP LX Wall is ideal for dual use applications where a visual alarm device is required in addition to an audible alarm. The RoLP LX Wall is available to use with any standard RoLP sounder. Typical applications: The Symphoni LX Wall base can be used in combination with any standard Symphoni sounder. Its high sound output makes it suitable for open areas or areas where there is higher than normal background noise. Typical applications: The Symphoni LX WP Wall device offers a weatherproof alternative to the Symphoni LX Wall device. With an ingress protection rating of IP66, it is suited for wet and outdoor environments. Performance Solista LX wall Sound output N/A Minimum current consumption EN54-23 coverage reference Coverage volume Flash rate Ingress protection 10mA W-2.4-7.5 135m3 (15m3) 1Hz (switchable to 0.5Hz) IP33C Solista LX ceiling N/A 10mA C-3-7.5 132m3 (21m3) 1Hz (switchable to 0.5Hz) IP33C RoLP LX wall 102dB(A) (Typical tone 3 - RoLP) 22mA W-2.4-7.5 135m3 (15m3) 1Hz (switchable to 0.5Hz) IP65 Symphoni LX wall 100dB(A) (Typical tone 3 - Symphoni) 15mA W-2.4-7.5 135m3 (15m3) 1Hz (switchable to 0.5Hz) IP21C Symphoni LX WP wall 100dB(A) (Typical tone 3 - Symphoni) 15mA W-2.4-7.5 135m3 (15m3) 1Hz (switchable to 0.5Hz) IP66 80 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Conventional systems Devices - EN54-23 visual alarm devices Dimensions 9D3mima 93mm D9i3amm 93mm W95mm 135mm H 135mm 95mm SHALLOW BASE DEEP BASE SHALLOW BASE DEEP BASE D D D D D Solista LX wall W Solista LX ceiling W RoLP LX wall H D D Symphoni LX wall H Symphoni LX WP wall Description Solista LX wall deep base Solista LX wall shallow base Solista LX ceiling shallow base RoLP LX wall Symphoni LX wall Symphoni LX WP wall Dia (mm) 93 93 93 - D (mm) 66 38 37 95 92 92 W (mm) - 95 106 106 H (mm) - 135 147 147 Catalogue numbers Description Solista wall red body shallow base Solista wall red body deep base Solista LX ceiling RoLP wall red body base and sounder RoLP wall red body base only Symphoni LX wall red body Symphoni LX wall weatherproof red body Code FXSOLWRS FXSOLWRD FXSOLCWS FXROLPWR FXROLPWR-B FXSYG1WR FXSYG1WR-WP Description DeeFpobrasme foorrSeoligstauLidX acenilicnge on EN-54-23 and placement of VADs, refer to our Fire Installer's Mate pocket guide. Code cc2478 Fire Systems & VADs Design Guide.qxp_Layout 1 12/02/2014 09:37 Page 1 FX000WWP Fire Systems Design Pocket Guide BS 5839 Part 1:2013 and CoP 0001 for Visual Alarm Devices Fire Installers Mate A guide to fire system design EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 81 Conventional systems Devices - indicators Indicators In areas which do not have to meet the new regulations regarding EN54-23 visual alarm devices, our range of indicators can still provide reliable light indication. Low profile LED indicator MLB124SB Weatherproof LED indicator MLB124DB Typical applications: Typical applications: In regions where the EN5423 VADs standard is not a requirement, the LED indicator can be used as an indicating device. The weatherproof version of the LED indicator provides an IP65 option ideal for outdoor use. Dimensions D D Dia Low profile LED indicator Dia Weatherproof LED indicator Description Low profile LED indicator Weatherproof LED indicator W (mm) 95 95 D (mm) 53 80 Note: From 31st December 2013 a new beacon standard, EN 54-23 became mandatory across Europe where Construction Product Regulation (CPR) applies. If you are in a region where this standard applies please understand that these indicators do not meet the requirements of the new standards - see p80 for compliant beacons and sounder beacons Features Ingress protection MLB124SB IP54 MLB124DB IP65 Catalogue numbers Description Low profile LED beacon Weatherproof LED beacon Code MLB124SB MLB124DB 82 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Conventional systems Devices - sounder indicators Sounder indicators In areas which do not have to meet the new regulations regarding EN54-23 visual alarm devices, our range of sounder indicators can still provide excellent sound quality and light indication. Xenon sounder Weatherproof Xenon indicator sounder indicator Dimensions FL-RL-R-S FL-RL-R-D D D Dia Xenon sounder indicator Typical applications: In regions where the EN5423 VADs standard is not a requirement, the xenon sounder indicator provides an alternative option to the xenon indicator - where an audible warning is required in addition to light indication. Typical applications: The weatherproof version of the sounder indicator is IP65 rated which allows for installation in harsher environments. Description Xenon sounder indicator Weatherproof xenon sounder indicator Dia Weatherproof xenon sounder indicator Dia (mm) 93 93 D (mm) 92 121 Sound output XENON sounder indicator, FL-RL-R-S/FL-RL-R-D Sound output 101dB(a) at 24V dc (typical tone 3) Tones 32 Features Ingress protection FL-RL-R-S IP54 FL-RL-R-D IP65 Note: From 31st December 2013 a new beacon standard, EN 54-23 became mandatory across Europe where Construction Product Regulation (CPR) applies. If you are in a region where this standard applies please understand that these indicators do not meet the requirements of the new standards - see p80 for compliant beacons and sounder beacons Catalogue numbers Description Conventional xenon sounder indicator Weatherproof IP65 xenon sounder indicator Code FL-RL-R-S FL-RL-R-D EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 83 Conventional systems Devices - door retainers and relay unit Door retainers and relay unit Door retainers enable doors to be held open under normal conditions but automatically be released in the event of fire alarm activation. Eaton have a range of door retainers which are robust and simple to install. Both floor and wall mounted retainers, with either mains or 24V dc power supplied variations, are available. Heavy duty door retainer MDR240/MDR24L Compact door retainer Heavy duty relay unit FX021240LC/ MAR724 FX02124VLC Typical applications: Robust and simple to install, the heavy duty door retainer is ideal for a wide range of applications, such as nursing homes, hospitals, schools and industrial premises. Typical applications: Equally as reliable, the compact door retainer is also a good choice for nursing homes, hospitals and also busy corridors. Typical applications: Designed for interfacing heavy loads such as door release units or plant shut down equipment with fire alarm systems. This unit is simple to fix and install and the neat unobtrusive design makes it suitable for use in a wide range of areas. The heavy duty relay unit is powered by 24V dc external supply and is provided with 2 separate sets of changeover contacts. Can switch 230V ac mains at 10A Performance Holding force Power consumption Ingress protection MDR240 MDR24L FX021240LC FX02124VLC 40kg 40kg 45kg 40kg 1.2VA 40mA 1.2VA 40mA IP40 IP40 IP42 IP40 Catalogue numbers Description Mains powered heavy duty door retainer 24V dc heavy duty door retainer Floor mounting bracket for heavy duty door retainers Mains powered compact door retainer 24V dc compact door retainer Floor mounting bracket for compact door retainers Spare striker plate for either magnet Heavy duty relay unit Code MDR240 MDR24L ZMDRFBB FX021240LC FX02124VLC FX021LCFB ZMDRSWIV MAR724 84 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Power supply Specifically recommended as an auxiliary power supply unit for fire detection system components such as electromagnets, notification devices, etc. Using the unit in large systems eliminates the problem of long power cable runs which simplifies installation. EN54 pt.4 approved power supply unit SPS Range Conventional systems Devices - power supply Typical applications: The new range of EN 54-4 certified safety power supplies offer a compact, robust and versatile power solution to installers, allowing them to safely power fire detection and signaling systems in small to large installations. Compact and discrete design allows for these SPS to be installed in a visible location such as a hotel lobby for instance. Comprehensive yet simple status indicators on the front of the unit help installers, commissioners and maintainers assess status of the unit. Features Ingress protection SPSS-2423/2433/2453 IP30 Catalogue numbers Description Safety power supply 24V / 1.5A (batteries not supplied) Safety power supply 24V / 2.5A (batteries not supplied) Safety power supply 24V / 4.5A (batteries not supplied) Code SPS-2423 SPS-2433 SPS-2453 Door retainers enable doors to be held open under normal conditions but automatically be released in the event of fire alarm activation. EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 85 86 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Notes EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 87 Introduction Section Name Spring Mews London, UK 88 EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019 Contact details Sales and technical support Contact Eaton Eaton Electrical Systems Ltd Wheatley Hall Road Doncaster South Yorkshire DN2 4NB United Kingdom www.cooperfire.com www.eaton.com Sales T: +44 (0)1633 628 566 F: +44 (0)1302 367 155 E: FireCustomerService@eaton.com Service T: +44 (0)1302 303 352 F: +44 (0)1302 303 332 E: FireService@eaton.com Technical T: +44 (0)1302 303 350 F: +44 (0)1302 303 332 E: FireTechSupport@eaton.com Export T: +44 (0)1302 303 344 F: +44 (0)1302 303 345 E: FireExport@eaton.com Online Resources Visit www.eaton.com for the following resources: · 24/7 online product support · Catalogue and literature · Product profiles · Datasheets, installation and user manuals EATOENA-TOFINRE- AFINRDE VAONIDCEVOAILCAERAMLASRYSMTESMYSSTE20M1S4 CF-CC2556 June 20147 89 At Eaton, we're energized by the challenge of powering a world that demands more. With over 100 years experience in electrical power management, we have the expertise to see beyond today. From groundbreaking products to turnkey design and engineering services, critical industries around the globe count on Eaton. We power businesses with reliable, efficient and safe electrical power management solutions. Combined with our personal service, support and bold thinking, we are answering tomorrow's needs today. Follow the charge with Eaton, visit eaton.eu UAE Middle East Headquarters Techno Park, Jebel Ali (South) P.O Box 261768 Dubai, United Arab Emirates Tel: +971 4 8066100 Fax:+971 4 8894813 Kuwait Shayma Tower, Mezzanine Floor Omar Bin al Khattab Street Sharq Kuwait Tel: +965 22253606 Fax:+965 22253608 Saudi Arabia King Abdullah Street (Ex. Dhahran St.) Dhahran Centre, 1st Floor Office 101 P.O Box 620 Al-Khobar 31952, Saudi Arabia Tel: +966 1 38825424 / 8825680 Fax:+966 1 38825732 Saudi Arabia Saad Al-Ajlan Trade Centre 1st Floor Office 9, Olaya Main Stret P.O Box 19651 Riyadh 11445, Saudi Arabia Tel: +966 1 4602275 / 288-6238 Fax:+966 1 14602291 Eaton Electrical Sector EMEA Route de la Longeraie 7 1110 Morges, Switzerland Eaton Eaton Electrical Systems Ltd. Wheatley Hall Road Doncaster South Yorkshire DN2 4NB United Kingdom Tel: +44 (0)1302 303 999 Fax: +44 (0)1302 303 333 Email: FireSales@eaton.com Web: www.cooperfire.com www.eaton.com © 2019 Eaton All Rights Reserved Pub Reference: CF-CC2556 August 2019 Lebanon Sin El Fil, Saydet Al Wardiyeh Street Beirut Symposium Building 2nd Floor, Office 2A Tel/Fax: +961 1 494711 Oman Maktabi building, Office No 208 Near Zakher Mall, Al Khuwair PO Box 1982, PC 111 CPO Oman Tel: +968 24391973 Fax:+968 24483801 Qatar Greedco 1 Building, Office no 4303 PO Box 91357, C Ring Road Doha, Qatar Tel: +974 4467273 Fax: +974 44667134 Egypt Building No. 289 Off 90th Street Apartment 4B, 4th Street 5th District, New Cario, Egypt Tel: +202 261 357 47 +202 261 357 46 Jordan Amman-Mekkia & Madina Streets Intersection Al-Haramien intersection. Al Hajar Al Aswad Cplx, 3rd floor - Office 306 Tel: +962 6 5542538 Iraq Burosan Bldg, 4th Floor, Office 10 60m Street, Kouran Intersection Erbil, IraqAdobe PDF Library 15.0 Adobe InDesign CC 2017 (Windows)