Xenon sounder beacon for conventional fire systems | Eaton

Complete fire systems for the protection of life and property

PDF jsb-fire-detection-systems-catalogue
Fire systems and devices

Product catalogue

JSB

Complete fire systems for the protection of life and property

We make what matters work.*
Every day, people depend on things like technology, transportation, energy and infrastructure to keep their daily lives on track. But without power, none of it would be possible. That's why companies around the world turn to Eaton. We're dedicated to improving people's lives and the environment with innovative technologies that help manage power more safely, reliably and sustainably. To meet today's challenges, and tomorrow's. Because this is what really matters. And we're here to make sure it works. To learn more go to: Eaton.com/whatmatters
We make what matters work.

*

Leadenhall Building London, UK

4

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Introduction
Distinctive capabilities

Excellence and innovation in fire safety solutions.
When it comes to protecting life and property there's no room to compromise. You need a partner that can support you with tried and tested products, global capabilities and local delivery.
Eaton is a leading manufacturer and global supplier of high quality fire systems. With our ability to provide complete systems, not just components, you can be confident in the knowledge that all of our products have been specifically designed and tested to ensure that they are all fully compatible to form a reliable and compliant fire detection and alarm system.
Our large multi-disciplined research and development team is responsible for the integration of the latest technology into the full range of fire products, ensuring that our products are designed to the latest fire industry standards and manufactured to the highest levels of quality. The many innovative, new and improved products featured in this catalogue demonstrate our commitment to staying at the leading edge of technological development for fire detection and alarm equipment.
Our core values and aims are:
· Investment in people · To partner with our customers to develop open, long term relationships · To have an unpretentious, straightforward and honest approach to
business · The continued investment in research and development · Investment in manufacturing facilities to ensure they remain world class · To produce products that are in full compliance with standards · To operate in an environmentally friendly way - in the products we design
and the facilities in which we make them · To have high ethical standards
Our solutions and services are recognised by a wide range of accreditation bodies, so you can count on products that comply with national and industry standards, while receiving full support, from initial system design to monitoring and service.

SS PREVENT

LO

ION CERTIFI
LPCB

RD

CATIO N BOA

SIGNALING

4AC5
FIRE ALARM EQUIPMENT

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

5

Introduction
Distinctive capabilities

Ankara Esenboa International Airport Ankara, Turkey

St Pancras Station London, UK

6

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Doncaster Cultural and Civic Quarter Doncaster, UK

Introduction
Distinctive capabilities

Manufacturing fire solutions is just one small element of what we do.

Services We believe that ownership of fire detection systems extends beyond the initial purchase of the products themselves. We therefore offer customers a wide range of services to ensure that their installations not only meet basic operational and safety requirements on day one, but will continue to do so throughout their lifetime. From training and support on how to select products for a specific application through to the provision of routine on-site testing and maintenance. You can be sure that Eaton is ready to support you, whatever your needs.
Major projects
Design and installation of a fire detection system can often be a complex process, with each project often bringing its own challenges in making sure the system is compliant, reliable and easy to operate. Our team of engineers will partner with your project management team using our expertise to meet the specific requirements of your project.
Eaton has a great deal of experience handling major projects across the globe. We can help not just with the product and technical support but also by providing guidance and advice to specifiers and project management teams on topics such as standards and regulations.
We are BAFE SP203 certified for design, commissioning and maintenance of fire detection systems, giving our customers the peace of mind they need that our systems conform with all necessary safety requirements.
Technical support
Our dedicated technical support team are able to offer customers around the world advice and guidance on a wide variety of technical matters via telephone or email. In the vast majority of cases, a process of systematic questioning enables the team to diagnose the challenge and advise the customer on the appropriate solution.
Sometimes more detailed troubleshooting and analysis methods may be used to determine the actual requirements and the best way of resolving it. If necessary, the technical support team will also call on the knowledge and expertise of Eaton's product management, R&D and design departments to help resolve the customer's issue.
In addition, the technical support team can provide customers with assistance on product information, installation and operating instructions, and the legislative requirements of your fire detection systems.

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

7

Introduction
Contents

Mariner's Quay Apartment Complex Newport

8

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Introduction
Contents

Contents

1. Introduction

An introduction to fire systems

10

Conventional and two-wire systems

12

Addressable systems

13

Emergency voice communication systems

14

UL listed fire systems

15

Voice alarm systems

15

2. Intelligent addressable systems

Fire panels and repeater panels

18

Addressable devices

24

3. UL intelligent addressable systems

Fire panels and repeater panels

48

UL listed devices

50

4. Conventional systems

Fire panels and repeater panels

62

Conventional devices

70

5. Appendix

Notes

87

Contact details

89

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

9

Introduction
An introduction to fire systems

An introduction to fire systems
Eaton manufacture and supply a range of different types of fire systems, meaning we can provide a high quality fire solution whatever your need is.
There are a vast array of fire detection systems and devices on the market today, ranging from the relatively simple to the most technically sophisticated. Modern automatic fire detection systems are available in two types, conventional and addressable - which, broadly speaking, tend to be used in smaller and larger installations respectively. For more detail you can read our fire systems guide over the next few pages.
The basics of fire detection
A control panel is the hub of the detection system. All the devices which are part of the fire detection system are connected to this central panel which processes the signals received from the input devices and gives out signals to the output devices. Input devices such as detectors measure signals of combustion and communicate with panels, which in turn trigger output devices such as an audible or visual alarm device. Fire alarm panels can be further sub segmented into addressable or conventional panels.
There are various types of fire detection systems each suited to different applications or building types. A fire detection system can vary significantly in both complexity and price, from a single panel with a detector and sounder in a small commercial property to a complex intelligent addressable system in a multi-occupancy building.
A fire detection system can comprise of detection devices, notification devices and manual callpoints. The size of the building determines the number of detectors that would be required. The system works via the control panel receiving signals from the detection devices and then sending transmitting signals to the notification devices.

10

EATON - FIRE ASYNSDTVEOMISCEAANLDADREMVSICYESSTECMFS-CC2F-5C5C625A5u6guJsutn2e0219017

Introduction
An introduction to fire systems

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

11

Introduction
Conventional fire systems

Conventional systems (p61-85)

Two-wire systems

The philosophy of a conventional system revolves around dividing the building into a number of areas called zones. The detectors and call points within each zone are then wired on a dedicated separate circuit.

Two-wire systems are based on standard conventional system technology, but it also incorporates additional functionality to enable the callpoints, detectors and sounders for each separate zone to be wired on a single common circuit.

In the event of a detector or call point being triggered, the panel is able to identify which circuit contains the triggered device and thereby indicate which zone the fire alarm has come from. The indicated zone can then be manually searched to locate the triggered device.

By combining both the detection and the alarm annunciation wiring into a single circuit, considerable savings in installation time and cabling can be achieved.

With this type of functionality a conventional system is best used in smaller builds where it wouldn't be difficult to locate the triggered device in a given zone.

Zone 1

Zone 2

Typical conventional system architecture

Zone 3

Zone 4

Typical two-wire system architecture

Example conventional system layout

Example two-wire system layout

12

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Introduction
Addressable fire systems

Addressable systems (p17-44)
Intelligent addressable systems overcome the limitations of conventional systems as each fire detecting sensor or call point is electronically coded with a unique identification or 'address' which is programmed into the device during installation.
By using each devices' unique address, the control panel is able to conduct two way communication with any of the addressable devices connected to the system.
Under normal conditions the control panel continuously interrogates each device in sequence and analyses the reply to determine the status of each sensor or call point. The panel checks whether each device is functioning correctly and also the amount of smoke or heat that the device is currently sensing.
With the functionality of being able to pinpoint exactly which device is being triggered in an alarm or for a fault, addressable systems are perfect for mid to large size builds with multiple rooms and floors.

Zone 1

Zone 2

15

16

14

1

2

3

13

4

12

11

10

9

5

6

8

7

Zone 3

Zone 4

Typical addressable system architecture

Example addressable system layout

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

13

Introduction
Emergency voice communication systems

UL listed fire systems (p46-59)

Underwriters Laboratories Inc. (UL) is an independent product safety certification organisation, established in 1894, to develop standards and test procedures for products, materials, components, assemblies, tools and equipment. Chiefly dealing with product safety it also evaluates and certifies the efficiency of a company's business processes through its magnificent system registration programs.
Since the launch of our UL Listed fire product range, several prestigious projects worldwide have been supplied including Hyatt Resort and Spa, Shangri-la at the Fort and Times Square projects

in South East Asia and several major projects in the Middle East including the prestigious Riyadh Financial District in the Kingdom of Saudi Arabia. The Eaton UL range is designed to provide a solution for all sizes of project, from the simple small stand alone system to the large multi panel networked system with PA/VA and BMS integration.
SIGNALING
4AC5
FIRE ALARM EQUIPMENT

14

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Notes

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

15

16

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Intelligent addressable systems
Contents

Contents
Intelligent addressable systems

Panels

FX2000 addressable panel

18 FX6100 addressable panel 20 FX6000 addressable panel

22

Devices
Sensors

24 Bases

26 Callpoints

28

Wall sounders and VADs

29 Beam detector

33 Duct probe

33

Interfaces

34 Micro interfaces

38 Networking interfaces

39

Ancillaries

41 Software

43 Test equipment

44

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

17

Intelligent addressable systems
FX2000
FX2000
Intelligent addressable control panel

"The FX2000 serves as the optimum solution for buildings requiring smaller addressable systems."

The Eaton FX2000 is an entry level intelligent

Benefits

addressable control panel which can be configured for either 1 or 2 loop operation, and is certified to EN54 parts 2 & 4.

· Configurable as a 1 or 2 loop panel
· Up to 200 addresses per loop (up to 60 sounders/beacons and up to 20 I/Os, subject

The panel has a graphic display, providing a simple menu driven end user interface. With the FX2000's ability to support Eaton cause and effect

to loop loading calculations) · Soft addressing · Menu-driven graphic screen

programming and a range of user controllable

· Multi-language selection capability

functions it makes the panel suitable for a varied

· Integral battery and power supply

range of projects from small warehouses to small/ medium office developments as well as many small industrial applications.

· 2x7Ah batteries included · Easy to operate end user controls · Full system integrity with Eaton developed

As with all Eaton intelligent addressable panels, the FX2000 uses "spur tolerant" soft addressing to

protocol · Core range of compatible devices

minimise installation time and remove the potential · 4 sounder circuits

for errors often associated with many forms of

· Monitored for open and short circuit (max

manual addressing.

3.0A combined)

ION CERTIFI

18

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

LPCB

SS PREVENT

CATIO N BOA

RD

LO

Dimensions
W
H

Intelligent addressable systems
FX2000
Compatible repeater panels
The FX2000 has a standard repeater panel available. Ideal for larger sites, the repeater allows you to display the system information from multiple locations.

H (mm) 400

W (mm) 320

D D (mm)
170

Features

FX2000

Ingress protection

IP30

Catalogue numbers

Description

Code

Addressable 2 loop control panel, standalone (FX2000) 910188FULL-0199

Addressable passive repeater

FX6000PR

Fire alarm system log book

MFALOG

Features
Active or passive option Integral battery and power supply Supervisor and engineer modes through code access Ingress protection

FX6000PR   
IP30

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

19

Intelligent addressable systems
FX6100
FX6100
Intelligent addressable control panel

"The simplicity of operation, powerful cause and effect programming capability and competitive pricing make the system suitable for a wide range of small to medium sized projects."

The FX6100 is a high specification addressable panel for medium sized builds that is equipped with a versatile touch screen user interface. It is available as a 1 (FX6100) or 2 (FX61002) loop panel.

The powerful cause and effect programming capability and competitive pricing make the system suitable for a wide range of small to medium sized projects. The panels can operate as standalone or as part of a network with our other addressable panels (additional network card required).

FX6100

FX61002*

No. of loops

1*

2*

Addresses per loop

200**

200**

No. of conventional sounder circuits

2***

2***

Ingress protection

IP30

IP30

* No zonal LEDs ** Up to 60 sounders/beacons and up to 20 I/Os ***Monitored for open and short circuit (max 1.5A combined)

Benefits · Soft addressing · Large versatile touch screen user interface · Multi-language selection capability · Integral battery and power supply · 2x7Ah batteries included · Flexible distributed network capability · Full range of compatible devices · Flexible and easy to design, system cause and effect using site installer software · Compatible with our addressable repeaters (see p21)

20

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Approved product

Dimensions

D

W

H

Panel Cutout

H (mm) 375 345

W (mm) 357 325

D1 (mm) 95 50

Intelligent addressable systems
FX6100

FX6100 pictured with a range of compatible devices

Catalogue numbers
Description 1 Loop Control Panel, VDS 2 Loop Control Panel, VDS Add to end of product code if network card required Dual redundancy network card Network Kit for DF6100/2 and CF11/CF12 Passive repeater panel Touch-screen repeater panel Fire routing equipment PCB Fire alarm system log book

Code FX6100 FX61002 NC NCDR DF61NETKIT FX6000PR FTPR6000 ZPCB2187FRE MFALOG

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

21

Intelligent addressable systems
FX6000

FX6000
Intelligent addressable control panel

"The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects"

The FX6000 series are high specification intelligent addressable control panels, which are fully certified to EN54 parts 2 and 4.

Benefits · Soft addressing · Large versatile touch screen user interface

Each panel is networkable with up to 126 other Eaton addressable control panels, only requiring the addition of one of our network cards for this functionality. Using our latest software, the panels can be set up for smoke management protocols, when used in conjunction with FC6 or FC18 fan controller units, and the new MCOM-FC interface module.

· Multi-language selection capability · Integral printer (optional) · Integral battery and power supply · 2x 12Ah batteries included · Extended battery option allows for 72 hours
standby (subject to loop loading calculations) · Flexible distributed network capability

FX60002

FX60004

· Full range of compatible devices

No. of Loops

2

4

· Easy to design system cause and effect using

Addresses per Loop

200*

200*

site installer software

No. of Conventional

4**

4**

Sounder Circuits

· Additional functionality through FRE & FPE

Ingress protection

IP30

IP30

(Fire Routing Equipment & Fire Protection

* Up to 60 sounders/beacons and up to 20 I/Os **Monitored for open and short circuit (max 1.5A combined)

Equipment) which are both monitored outputs
ION CERTIFI

22

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

LPCB

SS PREVENT

CATIO N BOA

RD

LO

Intelligent addressable systems
FX6000

Class change functionality
Our FX6000 panel has a variety of easy to use additional software options on top of the standard class change facility; this provides benefits for a number of regions.
Class change input on the FX6000 can be used for functions such as Australian Fire Brigade, HMO operation, Swedish mode, Australian tone sounders for class change and different tones.

Compatible repeater panels
The FX6000 has both a passive and a touchscreen repeater panel available. Ideal for larger sites, the repeater allows you to display the system information at multiple locations.

Features

FX6000PR

Active or passive option



No programming required

*

Programmable input



Integral battery and power



supply

Supervisor and engineer



modes through code access

Fire and fault volt free



programmable relays

Adjustable volume from panel



Ingress protection

IP30

*Programming not required on network version.

FTPR6000    


 IP30

Dimensions
D2 W
H

D1

Standard

H (mm) 397

W (mm) 497

D1 (mm) 55

D2 (mm) 125

Catalogue numbers
Description
2 loop control panel 4 loop control panel 2 loop control panel, integral printer 4 loop control panel, integral printer Add to end of product code if network card required If an additional loop card is required Network Kit for FX6000 Printer kit (for retro fit) Hinged protective cover kit Passive repeater panel Touch-screen repeater panel Fire alarm system log book

Code FX60002 FX60004 FX60002P FX60004-P NC ZPCB2148P2 DF6000NETKIT DF6000PKIT DF6000COV FX6000PR FTPR6000 MFALOG

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

23

Intelligent addressable systems
Devices - sensors

Sensors
Our addressable range has multiple options for intelligent addressable sensors. All sensors are designed for optimum functionality in mid-large sized builds. They are all soft addressed and have integral short circuit isolators. We also offer a loop connected remote indicator, designed to offer discreet remote indication and an ability to monitor multiple sensors. This helps to minimise wiring requirements.

Optical smoke sensor Photo-thermal sensor Heat sensor

FXN723

FXN722*

FXN725

Typical applications:
Suitable for most applications.
Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Typical applications:
Responds quickly to fast clean burning fires.
Maintains the advantage of optical sensors when detecting smouldering fires.

Typical applications:
Environments where the ambient conditions might cause false alarms with smoke detectors.
Examples include areas with high levels of dust or fumes.
The FXN725 can operate in 3 modes: rate of rise, fixed heat 77°C and fixed heat 90°C.
These modes are set by the panel.

*The FXN722 has day/ night modes available, programmeable from the site installer software. The day mode uses the heat aspect of the sensor for areas which may have smoky environments during, for example working hours. The night mode uses a combination of A2S and smoke detection. If not programmed, the sensor defaults to dual mode.

Dimensions

Performance

Dia

Feature

FXN723 FXN722 FXN725 FXN725 FXN725

Mode Area coverage*

Optical 100m2

Photothermal
100m2

Rate of rise
50m2

Fixed

Fixed

heat 77°C heat 90°C

50m2

50m2

Heat class

N/A

A2S

A2R

BS

CS

D1

D2

Alarm temperature N/A

60 °C

60 °C

77 °C

92 °C

Ingress protection IP30

IP30

IP30

IP30

IP30

*(subject to local standards)

Description Optical Photo-thermal Heat

Diameter (mm) Depth (mm)

(incl base)

(excl base)

104

33

104

43

104

43

Depth (mm) (incl base)
45 55 55

Catalogue numbers
Description Optical smoke sensor - FXN723 Photo-thermal sensor - FXN722 Multi-mode heat sensor - FXN725

Code 400002FIRE-0005X 400004FIRE-0007X 400003FIRE-0006X

24

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

ION CERTIFI
LPCB

SS PREVENT

CATIO N BOA

RD

LO

Intelligent addressable systems
Devices - sensors
Indicators
Our indicators are designed as additional indication devices when sensors have been triggered. These products are designed to be used as indicators only, and not visual alarm devices (see p26 and 29 for EN54-23 certified VADs).

Addressable remote indicator MRIAD

Standard remote indicator FX251D

Staff warning device FXN338BCN

Typical applications:
Monitoring multiple sensors within a specific area.
Must be configured through site installer. The remote indicator can be programmed as a sounder.

Typical applications:
The FX251D can only be connected to one sensor and is powered by this sensor.
There is a weather resistant version also available. (Not IP65).

Typical applications:
As this product does not meet EN54-23 requirements as a beacon we recommend it as an internal warning device in offices, schools or manned reception areas.

Remote indicator lens detail

Dimensions
D

D

H

Dia
Staff warning device

Description Staff warning device

Diameter (mm)
101

Description Remote indicators

Height (mm)
87

W
Remote indicators

Depth (mm) 33

Width (mm) 87

Depth (mm) 30

Catalogue numbers
Description Loop connected remote indicator Standard remote indicator Weather resistant standard remote indicator Staff warning device

Code MRIAD FX251D CIR301WP FXN338BCN

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

25

Intelligent addressable systems
Accessories - bases

Bases
We stock a variety of bases, providing a wide functionality for different situations. The standard base (FXN720) provides a foundation for our addressable sensors. The range of bases also includes capability for additional sounder and sounder beacon operation. Both our sounder base (FXN538) and VAD sounder beacon base (FXN577) can be used as standalone devices when fitted with our cover plate (CASC).

Standard base FXN720

Sounder base FXN538

Sounder beacon base FXN557 (FXN537)

Sounder base with cover FXN538 + CASC

Typical applications:
General use product, recommended for use in all environments

Typical applications:
Areas of limited extent, where lower output volume is required
Areas with limited cable space
Concrete ceilings, to save cabling

0.5Hz FLASH
Typical applications:
The FXN577 is an EN54-23 certified Visual Alarm Device (VAD) sounder beacon base.
It is compatible with the Eaton range of intelligent addressable sensors and can also be used as a dedicated discreet standalone device.
(The FXN577 sounder beacon base is also available for indication purposes, where EN 54-23 is not a requirement.)

Typical applications:
Optional cover plate can be used to enable the sounder to operate as a dedicated discreet stand alone device

Features
First fix base Loop integrity switch Multiple cable entry points Selectable tones Ingress protection

FXN720    

FXN538    
IP40

FXN537    
IP40

FXN557    
IP21C

VAD sounder beacon base shown with optical sensor

26

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

ION CERTIFI
LPCB

SS PREVENT

CATIO N BOA

RD

LO

Intelligent addressable systems
Accessories - bases

Performance
Sound output Low volume Medium volume High volume

FXN538
84dB at < 4mA 92dB at < 8mA 95dB at < 12mA

FXN557
77dB at < 6.6mA 89dB at < 8mA 90dB at < 9mA

Flash rate

n/a

0.5 Hz flash*

*Polar dispersion infromation available on datasheet

Dimensions

D

D

Dia D

Dia
Standard base
Description Standard base Sounder base Sounder beacon base

Dia
Sounder base

Sounder beacon base

Diameter (mm) 104 102 115

Depth (mm) 22 40 44

Catalogue numbers
Description Standard base Sounder base VAD sounder beacon base Sounder beacon base Cover plate (pack of 5) Base shroud

Code FXN720 FXN538 FXN557 FXN537 CASC BAR3000-1

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

27

Intelligent addressable systems
Devices - callpoints
Callpoints
Two versions of the intelligent addressable callpoint are available, the surface/ flush mounted FXN501 or the weatherproof FXN503. Both have an integral short circuit isolator and are very simple to install. The callpoints are packaged with 2 frangible glass elements and test key, with a comprehensive range of further accessories available.

Surface/flush mounted Weatherproof callpoint

callpoint

FXN503

FXN501

Dimensions
W

H

Typical applications:
General use product, suitable for use in most indoor applications.

Typical applications:
Builds requiring a callpoint in harsh conditions. For example, outside or in a wash down area.

D

Description Surface mounted Flush mounted Weatherproof

H (mm) 87 87 87

W (mm) 87 87 87

D (mm) 36 57 59

Features
Fast fit clip High Visibility LED Heavy duty terminals Ingress protection

FXN501    IP42

FXN503    IP65

Further accessories:

Catalogue numbers

Description

Code

Surface/flush callpoint

FXN501

Weatherproof callpoint

FXN503

CXPC Protective hinged cover (pack of 10) CXPC

MBGBEZ Recessing bezels (pack of 10)

MBGBEZ

MBGREKIT Resettable element kit (pack of 10)

MBGREKIT

Spare break glasses (pack of 5)

FX5G

MFBGKEY3 Callpoint keys (pack of 10)

MFBGKEY3

28

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Callpoint shown with protective hinged cover
Callpoint recessing bezel
ION CERTIFI
LPCB

SS PREVENT

CATIO N BOA

RD

LO

Intelligent addressable systems
Devices - wall sounders

Wall sounders and VADs

There are also two versions of our intelligent addressable wall sounder, the internal (FXN538LPS) and the weatherproof (FXN538LPSWP). Their highly efficient design offers excellent sound output levels despite the low current consumption. They both contain an integral short circuit isolator and have multiple tones and volume levels which can be controlled from the panel globally, or individually via site installer.
We also offer a new open class Visual Alarm Device (MASB880), combining the high output sound of the wall sounders with a stronger LED to meet the EN54-23 VADs requirements. The open class functionality allows the VADs to be installed in open areas such as warehouses or airport terminals.

Wall sounder

VAD wall

Dimensions

FXN538LPS/

sounder beacon

FXN538LPSWP

FXN559LPS/

w D

FXN559LPSWP

D

FXN539LPS/FXN539LPSWP

0.5Hz FLASH

H

H

Typical applications:
Both an indoor and weatherproof variant of the wall sounder are available, allowing for consistent performance for any application where a wall sounder is required.

Typical applications:
The FXN599 is an addressable open class VAD suitable for all markets where EN54-23 VADs are now a requirement. White flash only.
(The FXN539LPS wall sounder beacon is also available for indication purposes, where EN 54-23 is not a requirement. Red flash only.)

W
Internal wall sounder / sounder beacon

Description Wall sounder WP wall sounder VAD sounder beacon WP VAD sounder beacon

H (mm) 105 108 108 110

Weatherproof wall sounder/ sounder beacon

W (mm) 105 108 108 110

D (mm) 95 103 96 105

Tones
Continuous Two tone @ 1Hz cycle Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap Pulsed 1Hz (Virtual Tone) Pulsed sweep ISO8201 3x500ms 800-970Hz 1½ Sec Gap Bell tone

Sound output
FXN538LPS/ FXN538LPSWP

Low volume

87dB at < 2mA

Medium volume 93dB at < 3mA

High volume

100dB at < 6mA

Flash rate

n/a

FXN538LPS/ FXN559LPS/ FXN539LPS
Ingress protection IP42
ION CERTIFI
LPCB

FXN559LPS/ FXN559LPSWP
87dB at < 8.6mA
93dB at < 10mA
100dB at < 11mA
0.5Hz Flash
FXN538LPSWP/ FXN559LPSWP/ FXN539LPSWP IP66

FXN538LPS/ FXN538LPSWP
     
Catalogue numbers
Description Internal wall sounder Weatherproof wall sounder Vad wall sounder beacon Weatherproof VAD wall sounder beacon Wall sounder beacon Wall sounder beacon weatherproof

FXN559LPS/ FXN559LPSWP
     
Code FXN538LPS FXN538LPSWP FXN559LPS FXN559LPSWP FXN539LPS FXN539LPSWP

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

29

SS PREVENT

CATIO N BOA

RD

LO

Intelligent addressable systems
Devices - wall sounders

Wall sounder VAD

Dimensions

CASB493/CASB493WP

CASB483/ CASB483WP

NEW PRODUCT

Typical applications:
This EN 54-23 compliant sounder beacon visual alarm device (VAD) is suitable for fire notification in commercial buildings. The weatherproof variant, with an IP66 ingress protection rating, can be used in wet and outdoor environments.
Red (CASB483/WP) or white (CASB493/WP) flash options available.

Wall sounder VAD

Description
Wall sounder VAD Wall sounder VAD (weatherproof)

H (mm) 147 151

W (mm) 106 111

D (mm) 92 100

Wall sounder VAD (weatherproof)

Wall VAD CAB492W/CAB482W

Dimensions

NEW PRODUCT

Typical applications:
A low-profile, low-current solution to the latest EN 54-23 fire standard, this fire alarm beacon VAD. It is also compatible with a range of bases making it suitable for a variety of applications.
Red (CAB482W) or white (CAB492W) flash options available.

Wall VAD (shallow base)

Description Wall VAD (shallow base) Wall VAD (deep base)

H (mm) 93 93

W (mm) 93 93

D (mm) 38 67

Wall VAD (deep base)

30

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

-

Ceiling VAD

Dimensions

CAB492CS/CAB482CS

Intelligent addressable systems
Devices - wall sounders

NEW PRODUCT

Typical applications:
This EN 54-23 certified, lowcurrent fire alarm beacon is suitable for ceiling mounting. It is compatible with a shallow base providing flexibility as to where the VAD can be installed.
Red (CAB492CS) or white (CAB482CS) flash options

Description Ceiling VAD

Ceiling VAD
H (mm) 93

W (mm) 93

D (mm) 38

Tones
Flash rate (low power consumption) Operating current (depending on setting and LED colour) IP protection

CASB493/CASB493WP CASB483/CASB483WP
0.5Hz
13.4-47.5mA
IP21C WP variant : IP66

CAB492W/CAB482W
0.5Hz 12.5-45mA Shallow base: IP33C Deep base: IP65

CAB492CS/CAB482CS
0.5Hz 12.5-45mA
IP21C

Catalogue numbers

Description

Code

CASB493 Wall sounder VAD, red, white flash

8500110FULL-0199X

CASB483 Wall sounder VAD, red, red flash

8500111FULL-0197X

CASB493WP Wall sounder VAD, red, white flash, weatherproof 8500114FULL-0200X

CASB483WP Wall sounder VAD, red, red flash, weatherproof 8500115FULL-0201X

CAB492WS Wall VAD, red, white flash, shallow base 812033FULL-0209X

Description

Code

CAB492WD Wall VAD, red, white flash, deep base

812034FULL-0210X

CAB482WS Wall VAD, red flash, shallow base

812035FULL-0211X

CAB482WD Wall VAD, red, red flash, deep base

812036FULL-0212X

CAB492CS Ceiling VAD, red, white flash, shallow base 812050FULL-0269X

CAB482CS Ceiling VAD, red, red flash, shallow base 812037FULL-0214X

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

31

Addressable fire systems
Devices - beam detectors

Beam detectors, typically used in large open areas, such as airports, shopping centres and warehouses

32

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Intelligent addressable systems
Devices - duct probe detector

Beam detectors

Duct probe mounting kit

There are two available loop powered reflective beam detectors in the intelligent addressable range. The MAB50R has a range of up to 50 metres and the MAB100R has a range of up to 100 metres. Neither requires a power supply and are both equipped with a simple set up mode to enable easy and quick alignment during installation.
The beam detector is loop powered with one unique address, and has the ability to add address text at the panel. There is a maximum limit of 20 per loop (based on loop loading calculations).

The presence of smoke in a ventilation duct is detected by sampling the airflow through the duct via two sampling tubes. A detector and base are mounted within the sampling chamber, which is located on the external skin of the duct, with sample and exhaust probes passing into the duct in an area of low turbulence. The unit requires an addressable optical detector and base and is supplied with full fixing instructions.

Addressable reflective beam detector MAB50R / MAB100R

Dimensions

H (mm) 210

W(mm) 130

D (mm) 120

Duct probe unit MDP201

HD

Typical applications:
Large open areas such as warehouses, manufacturing plants, shopping centres, airports etc.

W
Allows access to the automatic gain control data from the detector. The beam detector will show fire, fault and pre-alarm.

Typical applications:
Detecting presence of smoke in ventilation ducts.
Requires base and detector to be ordered separately.

Duct probe unit shown with optical detector fitted

Features

MAB50R

Operating range

5 to 50 metres

Tolerance to beam misalignment Detector ± 0.8°,

at 35%

Prism ± 5.0°

Fire alarm thresholds

2.50dB (25%) 3.74dB (35%) 6.02dB (50%)

Optical wavelength

880nm

Ingress protection

IP40

MAB100R
50 to 100 metres
Detector ± 0.8°, Prism ± 5.0°
2.50dB (25%) 3.74dB (35%) 6.02dB (50%)
880nm
IP40

Features
Duct width range Duct air speed range
Temperature range Optical wavelength Ingress protection

300mm to 1500mm 5 to 50 metres
1m/s to 20m/s Detector ± 0.8° Prism ± 5.0°
-20°C or +60°C
880nm
IP67

Beam detectors have 3 operating modes:
Prism targeting mode designed to provide simple initial alignment of beam and reflector assembly.
Alignment mode enables accurate fine tuning of beam alignment without the need for additional calibration equipment or a second operator.
Normal running mode during standard operation.

Catalogue numbers

Description

Code

MAB50R Reflective beam detector (50m range) 400030FIRE-0067X

MAB100R Reflective beam detector (100m range) 400031FIRE-0071X

Mounting bracket

MRBFP

Spare reflector

MABR

Duct probe unit

MDP201

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

33

Intelligent addressable systems
Devices - interfaces

Interfaces
We supply an extensive range of interfaces to support our control panels. Interfaces allow for a wide variety of installations to be simplified without the use of specialist or customised equipment. For assistance deciding which interfaces will benefit you the most, contact our technical support team at firetechsupport@eaton.com

Zone monitor unit CZMU352

Spur isolator unit CSI350

Shop monitor unit MSU840

3 channel I/O unit CIO351

Typical applications:
The unit connects a zone of suitable conventional detectors (20 detectors per zone) and a separate zone of conventional callpoints (if required) to an addressable panel.
It allows for easier connection to existing conventional detection zones, as long as the devices used are compatible.

Typical applications:
The spur isolator unit enables a spur of intelligent addressable devices to be connected to a main analogue loop. This simplifies the installation of remote parts of buildings or system extensions.
The CSI350 doesn't take an address in the number sequence.
Recommended no more than a zones worth of devices per isolator.

Typical applications:
The shop monitor unit is designed to allow small units with conventional fire systems to be fully integrated with a main intelligent addressable fire system.
It is ideal for connecting individual shop units into a main shopping centre system.
Recommended for use with conventional VADs (see p80). Please note: A PSU (see p38) is required to operate conventional sounder circuits.
The MSU840 can have 2 sounder circuits, each with up to 0.3A of power.

Typical applications:
The 3 channel input/output unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits.
Relay contacts are rated at 30V dc 1A. See below for further options.

Dimensions
1
H D
Description Interface style 1 1 Interface style 2 2

D
2
W
H

H (mm) 88 129

W (mm) 147 180

W
D (mm) 60 60

Catalogue numbers
Description Zone monitor unit Shop monitor unit Spur isolator unit 3 channel input/output unit resets on reset (recognised as 1 address) 230V ac relay unit

34

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Code CZMU352 MSU840 CSI350 CIO351
CMIO353

Addressable fire systems
Devices - interfaces

230V ac relay unit CMIO353

4 to 20mA interface CGI420

Typical applications:
Enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems.
The ability of the output unit to switch 230V ac mains at 8A makes the unit ideal for plant control or mains powered door holders.
The input is monitored for open and short circuits therefore can be used for fire input applications such as monitoring sprinkler flow switches.
If you require higher current switching (10A) please see page 84 for MAR724.

Typical applications:
Designed to interface with gas detection modules and are compatible with Eaton intelligent addressable control panels.
The supply to the gas detector is taken directly from the interface.

Features
Ingress protection

CZMU352/CSI350/ CMIO353 MSU840/CIO351

IP40

IP65

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

35

Intelligent addressable systems
Devices - interfaces
Interfaces continued
4 way sounder controller unit CSC354CPR

Typical applications:
The 4 way sounder controller unit (CSC354CPR) adds functionality to your addressable panel by powering up to 4 lines of conventional output devices.
The CSC354CPR gives access to Eaton's extensive range of conventional devices, including EN54-23 certified VADs, beacons, signboards, bells and sounders.
It is ideal in situations where there is a requirement for devices with a high current draw or where conventional sounder circuits are in a remote location away from the fire alarm control panel.

Dimensions
Description 4 way sounder controller Unit

H (mm) 300

W (mm) 300

D (mm) 74

Catalogue numbers
Description 4 way sounder controller unit

Code CSC354CPR

Mimic relay boards CIOP4 / CIOP8

Typical applications:
These addressable mimic relay boards (CIOP4) and (CIOP8) are 4 and 8 way soft addressing output modules, incorporating integral short circuit isolators.
The units are suitable for switching low voltage (24V dc at 1A maximum), via a set of latching relay contacts.
The flexibility of these modules is further enhanced by the fact that each output can be programmed for a range of triggers such as disablement, fault, fire, test panel, test zone prealarm, fire routing equipment, fire protecting equipment and reset with up to 16 different trigger sources per output.
These units have an additional 4 inputs which can initiate a reset, silence, evacuate and test function.

Dimensions
Description CIOP4/8 mimic relay board

H (mm) 180

W (mm) 244

D (mm) 63

Features
Ingress protection

CSC354CPR IP30

CIOP4/CIOP8 IP65

D
H
W
Mimic relay

Catalogue numbers
Description 4 way mimic relay board, 4 inputs, 4 outputs 8 way mimic relay board, 8 inputs, 8 outputs 4 to 20mA interface

Code CIOP4 CIOP8 CGI420

36

EATON - FIRE ASYNSDTVEOMISCEAANLDADREMVSICYESSTECMFS-CC2F-5C5C625A5u6guJsutn2e0219017

Fan controller unit JFC6 and JFC18

Intelligent addressable systems
Devices - interfaces

Typical applications:
JFC18 and JFC6 fan controller units work in conjunction with the Eaton's range of intelligent addressable control panels, providing the capability to control and display the status of AHU fans.
The units are connected to the control panel by means of the comms loop, utilizing only one address whilst providing the ability to monitor and control up to 18/6 AHU fans. Each JFC18 and JFC6 unit incorporates its own CPU specifically configured to control the relevant input and output logic making programming quick and easy using Eaton site installer software.
Recently upgraded to be compatible with new Smoke Management protocols. Both JFC6 and JFC18 are ideal for use in conjunction with updated CF3000 panels and the new MCOM-FC interface module.

Dimensions
Description
JFC6 Fan controller unit (surface mount)
JFC18 Fan controller unit (rack mount)

H (mm) 125
133

W (mm) 155
482

D (mm) 42
30

H

H

W

D

JFC6 Fan controller unit (surface mount)

W D
JFC18 Fan controller unit (rack mount)

Catalogue numbers
Description Fan controller unit (surface mount) Fan controller unit (rack mount)

Code JFC6 JFC18

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

37

Intelligent addressable systems
Devices - micro interfaces
Micro interfaces
Whereas our standard interfaces are designed to be installed in the position required on the loop, our range of micro interfaces are compact enough to sit within a panels' enclosure, or in our dedicated mini module enclosure (ULBU) which can house up to 3 mini modules.

Micro zone monitor unit JIU872
Typical applications:
The micro zone monitor unit (JIU872) is suitable for interfacing a zone of up to 20 conventional detectors onto an intelligent addressable control panel.
It will operate with any conventional detector in configuration with a schottky diode type base (CDBB300).

Micro single channel input unit MJIM

Micro single channel output unit MJOM

Typical applications:
The micro single channel input unit (MJIM) is suitable for monitoring a set of normally open, volt free contacts such as sprinkler system flow switches and auxiliary panel fire/fault signals. Other examples include non-fire input signals such as flow valve open contacts, generator start up, fire door closed etc.

Typical applications:
The micro single channel output unit (MJOM) is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts.
It is also suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc.

Variants
The MJOM-R gives a 5 second pulse on reset, and is used for connecting/resetting beam detectors.
The MJOM-S is identified by the panel as a sounder and does not reset when put into 'silence' mode, only resets once panel has been reset.
The MJOM-FC is identified by the panel as sounder and will activate from its associate cause and effect programming. It will reset from a global reset not a global silence command. Suitable for use with fan controller devices for smoke management.

Installation into mini module box
1. Fit the unit in position in accordance to the mounting diagram below. 2. Connect the unit according to standard connections. 3. Up to 3 units can be fitted inside a micro module box unit

Features
Soft addressed Short circuit isolators Single address Ingress protection

JIU872   
IP40

MJOM   
IP40

MJIM   
IP40

180mm

FR4 PCB Interface Plate Secured to box with 2 self tapping screws.
60mm
130mm

Catalogue numbers

Description

Code

Micro zone monitor unit

JIU872

Micro single channel output unit

MJOM

Micro single channel output unit (sounder)

MJOM-S

Micro single channel output unit (reset on reset)

MJOM-R

Micro single channel output unit (fan controller output unit) MJOM-FC

Micro single channel input unit

MJIM

Mini module box unit (empty box)

ULBU

38

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Intelligent addressable systems
Devices - network interfaces

Network interfaces
Eaton offer multiple network interfaces which allow our panels and devices a wider variety of functionality. These network interfaces allow the connection of the Eaton network system to a computer network, and PC based applications such as site monitor, site graphic and web server.

Lon to RS232 adaptor EC0232

Dual-channel LonWorks TCP/IP interface

BMS interface

EC400

EC200

Lon network booster EC540

Typical applications: Typical applications: Typical applications: Typical applications:

The EC0232 Lon to RS232

The EC200 dual-channel

The EC400 is a high performance, The Lon network booster (EC540)

adapter allows connection of

LonWorks BMS interface is an

reliable and secure network

is the solution to interconnect

our system network (LonWorks) "add-on" to the network which

infrastructure device for accessing multiple EIA-709 channels.

devices to PC based applications such as site monitor, site graphics and web server.
In addition to the standard adaptor, Eaton offer 2 variants for use with a HMX PA/VA

translates the pre-configured

Eaton Lon Network of intelligent

network variables to a set of

addressable control panels over

un-configured network variables intranet or ethernet.

wBneMhtiwcSh,ogrckiavndinatgthaef.unllbaecFcbiebosursentdoOttohpaeticfirePoinTsdtehertevvoiceEerPCsm4oo0ain0nn'a1tsgLbIePuisnicltukhpianntcnooe2nl5fwi6gituIhProatuiot na

This unit provides up to 5 ports and routes packets between these ports. In spite of its small size the (EC540) provides best class performance and flexibility in use.

system - the ECO232PAVA with no handshaking, and the EC0232PAVA3D with a 3 min time delay.

LonWorks NODE
Control Panel &
Network Card

Lon-Fiber ADAPTOR
CFSFL02

LonWorks LonWorks

dedicated management PC.

In order to provide the optimal

Easy to uLnodner-sFtibanedr diagnosLtoicnWorks router configuration the (EC540)

FibrLeEDs alloAwDiAnsPtTaOlleRrs to instaNll OanDdE supports 2 to 5 ports as well as

tetrrxoopuuebbrllteekssnhhoooCwooFttliSentFhdgLeg0te2odoealvn.idcedewdNiCitcoheatnowttueroo&tdrlkPCaanredltsrhoweuitt2ecrhompmeoordadetei"n". ganmdo"dcoensf"isgmuraerdt

Fibre optic multi-drop link example network diagram

Fibre Optic Multi-Drop Link

Fibre

Fibre

Fibre

LonWorks Bus LonWorks Bus LonWorks Bus LonWorks Bus

CFSFL02
Lon-Fiber ADAPTOR
LonWorks NODE
Control Panel &
Network Card
LonWorks NODE
Control Panel &
Network Card

CFSFL02
Lon-Fiber ADAPTOR
LonWorks NODE
Control Panel &
Network Card
LonWorks NODE
Control Panel &
Network Card

CFSFL02
Lon-Fiber ADAPTOR
LonWorks NODE
Control Panel &
Network Card
LonWorks NODE
Control Panel &
Network Card

CFSFL02
Lon-Fiber ADAPTOR
LonWorks NODE
Control Panel &
Network Card
LonWorks NODE
Control Panel &
Network Card

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

39

Intelligent addressable systems
Devices - network interfaces

BACnet gateway EC650B

Modbus gateway EC700

Single mode Lon to fibre optic adapter CFSFL01

Dual channel Lon to fibre optic adapter CFSFL02

Typical applications:
The BACnet gateway (EC650B) is a CEA- 709/BACnet gateway which maps CEA-709 network variables (NVs) to standard BACnet server objects. When ordered with this part code (EC650B), the LonWorks to BACnet address mapping is preloaded and ready for use with the the intelligent addressable CF3000 system interface board.

Typical applications:
The modbus gateway is part of the InfraLINK range of network infrastructure components from partners.
All of the modbus gateways feature a robust hardware platform with high performance CPU and UART for fast communications without loss of data. The LonWorks to modbus address mapping is pre-loaded and ready for use with the CF3000 fire system interface board.

Typical applications:
The single mode Lon to fiber optic adapter (CFSFL01) allows connection of the system network (LonWorks) devices through optical fibre, and to allow both point to point or multi drop topology.

Typical applications:
The dual channel Lon to fiber optic adapter (CFSFL02) allows connection of the system network (LonWorks) devices through optical fibre, and to allow both point to point or multi drop topology.

Features
Ingress protection

EC400/EC540 IP40 (IP20 screws)

EC700 IP20

Catalogue numbers

Description

Code

Dual-channel lonworks BMS interface (non handshake) EC200

Dual-channel lonworks BMS interface (self configuring for use with EC700)

EC200S

Lon to RS232 adapter

EC0232

Lon to RS232 adapter (For HMX pa/va system - no handshake)

EC0232PAVA

Lon to RS232 adapter (For HMX pa/va system - 3 min time delay)

EC0232PAVA3D

Description TCP/IP interface Lon network booster Bacnet gateway Modbus gateway Single mode lon to fibre optic adaptor Dual channel lon to fibre optic adaptor

40

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Code EC400 EC540 EC650B EC700 CFSFL01 CFSFL02

Intelligent addressable systems
Devices - ancillaries

Ancillaries
A range of ancillaries are available to complement and extend the capability of our existing hardware.

Loop splitter unit ZPCB2222

Mimic PCB ZPCB2252-MML / ZPCB2252-MSL

SPS Range SPS-2423 SPS-2433 SPS-2453

Typical applications:
Allows expansion of the FX6000 intelligent addressable panel from 4 to 16 loops.
This interface is mainly applicable in countries where the mixing of detectors, sounders, callpoints and interfaces are not permissible on the same loop or the number of devices per loop is limited to a small number.

Typical applications:
Up to 250 outputs can be connected to the mimic PCBs (ZPCB2252-MML) and (ZPCB2252-MSL). This offers more capability to the extensive options already offered by the FX6000 control panel.
These boards are typical used for geographical LED mimic displays.

Typical applications:
Offers a compact, robust and versatile power solution to installers, allowing them to safely power fire detection and signaling systems in small to large installations.
Compact and discrete design allows for these SPS to be installed in a visible location such as a hotel lobby for instance.

Features
Ingress protection

SPS-2423/SPS-2433/SPS-2453 IP30

Catalogue numbers

Description Loop splitter unit Loop Mimic LED PCB (Master) Loop Mimic LED PCB (Slave) Loop Mimic Relay PCB (Master) Loop Mimic Relay PCB (Slave) Safety power supply 24V / 1.5A (batteries not supplied) Safety power supply 24V / 2.5A (batteries not supplied) Safety power supply 24V / 4.5A (batteries not supplied)

Code ZPCB2222 ZPCB2252-MML ZPCB2252-MSL ZPCB2252-MMR ZPCB2252-MSR SPS-2423 SPS-2433 SPS-2453

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

41

42

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Intelligent addressable systems
Devices - software and testing equipment

Software
Eaton offer a number of specialised programs to aid with the installation, maintenance, functionality and servicing of our addressable systems. Installed using the USB analogue systems panel interface (see p44) and a PC or laptop, these software programs help to solidify our addressable systems' capabilities and make it easier for users to control and organise the system on their site.

Graphical visualisation Site monitor

software

SITEMONITOR

EFGVS

Catalogue numbers

Description

Code

Graphical Visualisation Software license 1-2 panels including an EC0232 interface

EFGVS1-2

Graphical Visualisation Software license up to 6 panels including an EC0232 interface

EFGVS3-6

Graphical Visualisation Software license up to 10 panels including an EC0232 interface

EFGVS7-10

Graphical Visualisation Software license above 10 panels including an EC0232 interface

EFGVS11-PLUS

Graphical Visualisation Software license up to 10 panels with TCP/IP interlink

EFGVS7-10-TCPIP

Graphical Visualisation Software license above 10 panels with TCP/IP interlink

EFGVS11-PLUS-TCPIP

Graphical Visualisation Designer Software license - no panel connectivity

EFGVS-DESIGN

Typical applications:
Eaton Fire Graphic Visualisation Software (EFGVS) is a state of the art and powerful supervision management tool for Eaton Fire addressable systems.
Users can monitor, visualise in 2D and 3D, control and interrogate their systems to ensure alarms are located quickly and dealt with efficiently.
Ergonomic and intuitive, EFGVS includes a comprehensive list of advanced features offering the system designer and site supervisor a very efficient tool ensuring all information and controls be available at their fingertips.

Typical applications:
Site monitor / webserver software is designed to monitor Eaton fire systems and allow quick PC based administration.
Using a simple interface, authorised users can view control panel event history, event status, device properties and other information depending on access permissions defined by the system administrator.

Description

Code

Graphical Visualisation Premium Designer Software license including an EC0232 interface

EFGVS-PREMIUMDESGN

Interface to connect panel network (LONWorks) to PC (RS232)

EC0322

Site monitor / webserver software

EF-SITEMONITOR

All software products except SITEMONITOR include EC0232 (p36) as standard

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

43

Intelligent addressable systems
Devices - software and testing equipment
Testing equipment
As well as offering complete fire systems, Eaton can also provide testing equipment to ease the process of installation, commissioning, maintenance and fault finding.

Loop tester kit LP800KIT

USB analogue systems Addressable device

panel interface

programmer

USBINT2

CF800PROG

Typical applications:
The loop tester kit is a hardware/ software combination that can be used to test, commission and fault find a loop of up to 200 intelligent addressable devices (sensors, sounders, ancillary devices) without having to connect the loop to the intelligent addressable control panel.
The loop tester is connected between the loop and PC, and allows the engineer to quickly identify and locate any loop device that is operating outside its operating conditions.

Typical applications:
The analogue systems panel interface is a universal serial bus converter that provides conversions from RS232 to USB, TTL to USB or TTL to RS232.
These options provide the connectivity required between a PC and intelligent addressable control panels, wireless control panels, and wireless survey tools including our range of software solutions (see page 43).

Typical applications:
The addressable device programmer is a versatile tool to aid the installation, commissioning, maintenance and servicing of current intelligent addressable devices and fire systems.
This unit is light, robust and easy to operate using a user friendly menu structure on 2 x 40 character LCD display. It is powered from a single PP3 size, heavy duty battery or an external supply.
CF800PROG can:
Program sensor modes (see p24).
Change address details
Change heat detector settings
Read analogue levels

Catalogue numbers
Description Loop tester kit Addressable device programmer USB panel interface

Code LP800KIT CF800PROG USBINT2

44

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Notes

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

45

UL intelligent addressable systems
Product Name

UL Systems

Underwriters Laboratories Inc. (UL) is an independent product safety certification organisation, established in 1894, to develop standards and test procedures for products, materials, components, assemblies, tools and equipment. Chiefly dealing with product safety it also evaluates and certifies the efficiency of a company's business processes through its magnificent system registration programs.
Since the launch of our UL Listed fire product range, several prestigious projects worldwide have been supplied including Hyatt Resort and Spa,

Shangri-la at the Fort and Times Square projects in South East Asia and several major projects in the Middle East including a major projects within the prestigious Riyadh Financial District in the Kingdom of Saudi Arabia.
The Eaton UL range is designed to provide a solution for all sizes of project, from the simple small stand alone system to the large multi panel networked system with PA/VA and BMS integration.

46

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

UL intelligent addressable systems
Contents

Contents
UL listed fire systems range

Panels

ULFX6000 series panels

48

Devices
Addressable sensors

50 Conventional detectors

52

Horns and strobes

54 Pull stations

56

Interfaces

58 Micro interfaces

59

SIGNALING

4AC5
FIRE ALARM EQUIPMENT

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

47

UL intelligent addressable systems
ULFX6000 series
ULFX6000 series
UL listed control panels

ULFX6000RM (wall mount red metal)

ULFX6000 (wall mount graphite)

The ULFX6000 series panels are UL listed, high specification, wall or rack mounted fire panels. Combining sophisticated functionality with simple operation and aesthetically pleasing design, the panels are available in a number of loop configurations. Each panel is networkable with up to 126 other Eaton UL fire panels.
The control panel has the ability to support complex cause and effect programming. A wide range of user controllable functions make the system ideal for a diverse range of projects, from industrial applications through to large multi-site commercial developments.

Benefits

· Soft addressing

· Large versatile touchscreen user interface

· Integral printer (optional)

· Integral battery and power supply

· 2 x 12Ah batteries included

· Flexible distributed network capability

· Full range of compatible devices

· 4 notification appliance circuits (NACs) outputs

· 2 or 4 class A style 7 SLC loops

SIGNALING

· PAS (Positive Alarm Sequence)

48

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

4AC5
FIRE ALARM EQUIPMENT

Dimensions
D2 W
H

D2 W
H

UL intelligent addressable systems
ULFX6000 series

Description ULFX6000 ULFX6000RM

D1
H (mm) 397 398

W (mm) 497 505

D1 (mm) 75 48

D1
D2 (mm)
130 118

Compatible repeater panels
The ULFX6000 has both a standard and a touchscreen repeater panel available. Ideal for larger sites, the repeater allows you to display the system information from multiple locations.

Features
Active or passive option No programming required Multi language capability Allows networking with other Eaton fire panels Integral power supply Ingress protection *Except local text information

ULFX6000PR  *  
 IP30

ULFPTR6000    
 IP40

Catalogue numbers
Description 2 loop panel 4 loop panel 2 loop panel, integral printer 4 loop panel, integral printer 2 loop panel, network card 4 loop panel, network card 2 loop panel, integral printer, network card 4 loop panel, integral printer, network card

Code ULFX60002G ULFX60004G ULFX60002GP ULFX60004GP ULFX60002GNC ULFX60004GNC ULFX60002GPNC ULFX60004GPNC

Description 2 loop panel, network card, red metal box 4 loop panel, network card, red metal box Rack mounted 2 loop panel Rack mounted 4 loop panel Rack mounted 2 loop panel c/w network card Rack mounted 4 loop panel c/w network card Loop connected passive repeater panel Touchscreen network repeater panel

Code ULFX60002NCRM ULFX60004NCRM ULFXR6000L2 ULFXR6000L4 ULFXR6000L2NC ULFXR6000L4NC ULFX6000PR ULFPTR6000

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

49

UL intelligent addressable systems
Devices - addressable sensors
Sensors
Our UL range has multiple options for intelligent addressable sensors. All sensors are designed for optimum functionality in mid-large sized builds. They are all soft addressed and have integral short circuit isolators.

Addressable sensor base UCAB300

Optical smoke sensor Photo-thermal sensor Heat sensor

ULFX320

ULFX340

ULFX330

Typical applications:
Specifically designed for use with all of our UL addressable sensors, the UCAB base will be used in all builds.

Typical applications:
Suitable for most applications.
Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Typical applications:
Responds quickly to fast clean burning fires.
Maintains the advantage of optical sensors when detecting smouldering fires.

Typical applications:
Environments where the ambient conditions might cause false alarms with smoke detectors.
Examples include areas with high levels of dust or fumes.

Sensor detail

Addressable base detail

50

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

SIGNALING
4AC5

UL intelligent addressable systems
Devices - addressable sensors

Performance

Heat Class

ULFX320

Heat element rating N/A

Heat detector spacing N/A

Heat class

N/A

ULFX340
135°F
50ft (heat alone operation)
A2S

ULFX330 ROR + Fixed 135°F, Fixed 135°, Fixed 194°F 50ft
A2R

Dimensions
Dia

D1 D2

Description Optical Photo-thermal Heat

Diameter (mm) Depth (mm)

(incl base)

(excl base)

104

33

104

43

104

43

Depth (mm) (incl base)
45 55 55

Features
Ingress protection

ULFX320 IP30

ULFX340 IP30

ULFX330 IP30

Catalogue numbers
Description ULFX320 Optical smoke sensor ULFX340 Photo-thermal sensor ULFX330 Heat sensor Addressable sensor base Addressable sounder base

Code 400005FIRE-0017X 400006FIRE-0018X 400007FIRE-0019X UCAB300 ULFXN538LBS

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

51

UL intelligent addressable systems
Devices - conventional detectors

Detectors
Our UL range has multiple options for conventional detectors. All detectors have a removable detector chamber and drift compensation. The range of detectors for different applications allow for all build requirements to be met.
As there is no UL certified conventional panel a ULMIU872 micro interface (p59) is required in conjunction with a UL intelligent addressable panel to use conventional detectors.

Optical smoke detector UCPD-2W

Photo-thermal detector UCPT-2W

Fixed heat detector (135°F) UCHT-2W

Typical applications:
Suitable for most applications.
Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Typical applications:
Responds quickly to fast clean burning fires.
Maintains the advantage of optical sensors when detecting smouldering fires.

Typical applications:
Environments where the ambient conditions might cause false alarms with smoke detectors.
Examples include areas with high levels of dust or fumes.

Performance
Heat class Heat element rating Heat detector spacing
Mounting position

UCPD-2W UCPT-2W UCHT-2W

N/A

135°F

135°F

N/A

50ft (heat alone 50ft

operation)

Ceiling in open Ceiling in open Ceiling in open

areas

areas

areas

Features
Ingress protection

UCPD-2W IP40

UCPT-2W IP40

UCHT-2W IP40

52

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

SIGNALING
4AC5

UL intelligent addressable systems
Devices - conventional detectors

Conventional detector base CB2E

Typical applications:
The CB2E has been specifically designed for compatibility with our UL range of conventional detectors. It can be be used in all builds with conventional detectors.

Dimensions
Dia
D1 D2

Catalogue numbers
Description 2 wire detector, optical 2 wire detector, opto-heat 2 wire detector, fixed heat 135°f Standard detector base

Code UCPD-2W UCPT-2W UCHT-2W CB2E

Description Optical Photo-thermal Heat

Diameter (mm) (incl base)
104 104 104

Depth (mm) (incl base)
45 55 55

Depth (mm) (excl base)
33 43 43

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

53

UL intelligent addressable systems
Devices - horns and strobes
Horns and strobes
Our UL range incorporates a variety of audio and visual notification devices. Each device has up to 48% savings in current draw compared to similar products. The whole range is easy to install and has voltage test points for quick troubleshooting and easy spot checking, saving time on both installation and maintenance.

Wall mount horn HNR

Ceiling mount horn HNWC

Wall mount horn strobe/synchronised strobe HSR/STR

Ceiling mount horn strobe/synchronised strobe HSWC/STWC

Typical applications:
The horns are ideal for retrofit jobs, limited space environments and pre-existing wire configurations.

Typical applications:
The horns are ideal for retrofit jobs, limited space environments and pre-existing wire configurations.

Typical applications:
With the range of settings for both audio and visual purposes, these products are effectively 9 models in 1 appliance. With this functionality, and both ceiling and wall mount options available, it will meet almost any build requirements.
The synchronised option enhances both the sound and light output by keeping the outputs of multiple devices in sync.

Dimensions

W

W

D

D

Dia

D

H

Description
Wall mount horn HNR
Wall mount horn strobe/ synchronised strobe HSR/STR

H (mm) 133
131

W (mm) 116
131

D (mm) 56
110

Description
Ceiling mount horn HNWC
Ceiling mount horn/ synchronised strobe HSWC

Diameter (mm) 166

Depth (mm) 34

166

34

54

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

SIGNALING
4AC5

UL intelligent addressable systems
Devices - horns and strobes

Wall mount outdoor synchronised strobe RSSWP-2475W-FR

Ceiling mount outdoor synchronised strobe RSSWP-2475C-FW

Typical applications:
The outdoor synchronised strobes are UL certified to meet adverse weather conditions. They are perfect for builds where outdoor indication is required.
These units use a universal, common mounting base making them ideal for retrofit jobs, limited space environments and pre-existing wire configurations.

Dimensions

W

D

H

Description

H (mm)

RSSWP*

131

*Both wall mount and ceiling mount variants

W (mm) 131

D (mm) 110

Catalogue Numbers

Description

Code

HNR Wall mount horn

HNR

HNWC Ceiling mount horn

CN128972

HSR Wall mount horn strobe

HSR

HSWC Ceiling mount horn strobe

CN127464

STR Wall mount synchronised strobe

STR

STWC Ceiling mounted synchronised strobe CN127488

RSSWP-2475W-FR Wall mount outdoor synchronised strobe

CN129013

RSSWP-2475C-FW Ceiling mount outdoor synchronised strobe

CN124446

WPSBB -R Exposed conduit, surface mount back box (RED)

CN109751

WPSBB-R + WP-KIT Concealed conduit surface CN109751 + CN104486 mount back box (RED)

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

55

UL intelligent addressable systems
Devices - pull stations

Pull stations
The addressable pull stations are constructed of high quality, die cast metal for long lasting performance. The range consists of the UL listed MPS range of pull stations and the UL listed fast response input initiating module (ULMCIM-C).

Single action addressable pull station UMPS-100/ UMPS-100WP

Single action conventional pull station SG42BK2

Typical applications:
Indoor/weatherproof pull station for use with addressable systems (UMPS-100/UMPS-100WP).
A dual action model is also available (UMPS-200, not shown), where the push bar rotates inward allowing the pull handle to be grasped in a one handed motion.

Typical applications:
Cost effective conventional version of the single action pull station, must be used in conjunction with ULMIU872. Back box ordered seperately.

Pull station detail

Dimensions
D
H

W

H (mm) 118

W (mm) D (mm)

80

80

Catalogue numbers
Description Single action pull station, supplied with back box (addressable) Weatherpoof single action pull station Double action pull station Weatherproof double action pull station ULMIU872 Micro zone monitor unit ULMCIM-C micron single channel input unit (call point) Conventional single action pull station (back box ordered seperately) Conventional double action pull station (back box ordered seperately) Indoor back box for conventional, surface mounting Weatherproof back box for conventional, weatherproof

Code UMPS-100
UMPS-100WP UMPS-200 UMPS-200WP 400025FIRE-0054X 400014FIRE-0057X SG42BK2
SG42BK1
SGB32S SGB-32C

56

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

SIGNALING
4AC5

UL intelligent addressable systems
Product Name

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

57

UL intelligent addressable systems
Devices - interfaces

Interfaces
We supply an extensive range of interfaces to support our UL control panels. Interfaces allow for a wide variety of installations to be simplified without the use of specialist or customised equipment. For assistance deciding which interfaces will benefit you the most, contact our technical support team; firetechsupport@eaton.com

4 Way Sounder Controller Unit ULCSC354

Shop monitor unit ULCSUM355

Spur isolator unit ULCSI350

3 channel I/O unit ULCIO351

Typical applications:
The unit connects 4 lines of conventional output devices on a single address to an addressable panel. Ideal for when specialist devices with a high current draw are required, such as Eaton's UL ceiling and wall horns/strobes. Or where conventional sounder circuits are in a remote location away from the fire alarm control panel.

Typical applications:
The shop monitor unit is designed to allow small units with conventional fire systems to be fully integrated with a main intelligent addressable fire system.
It is ideal for connecting individual shop units into a main shopping centre system.

Typical applications:
The spur isolator unit enables a spur of intelligent addressable devices to be connected to a main analogue loop. This simplifies the installation of remote parts of buildings or system extensions.

Typical applications:
The 3 channel input/output unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits.

230V ac relay unit

Dimensions

ULCMIO353

D

D

H
H

Typical applications:
Enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems.
The ability of the output unit to switch mains also makes the unit ideal for plant control or mains powered door holders.
The input is monitored for open and short circuits so can be used for fire input applications such as monitoring sprinkler flow switches.

W
W

Description Interface units 4 way sounder controller unit

H (mm) 129 300

W (mm) D (mm)

180

60

300

74

Features

Ingress protection

ULCSC354 IP30

ULCSUM355 /ULCSI350/ ULCIO351/ULCMIO353
IP40

58

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

SIGNALING

4AC5

UL intelligent addressable systems
Devices - micro interfaces
Micro interfaces
Whilst our standard UL interfaces are designed to be installed in the position required on the loop, our range of micro interfaces can sit within a panels' enclosure.

Micro single channel Micro single channel

output units

input units

ULMCOM/ULMCOM-S ULMCIM/ULMCIM-C

Micro zone monitor unit ULMIU872

Dimensions

D

W

H

Typical applications:
The Micro Single Channel Output Unit (ULMCOM) is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts.
It is also suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc.
The ULMCOM-S is identified by the panel as a sounder.

Typical applications:
The Micro Single Channel Input Unit (ULMCIM) is suitable for monitoring a set of normally open, volt free contacts such as sprinkler system flow switches and auxiliary panel fire/fault signals. Other examples include non-fire input signals such as flow valve open contacts, generator start up, fire door closed etc.
The ULMCIM-C is identified by the panel as a call point and is designed for use with pull stations.

Typical applications:
The Micro Zone Monitor Unit (ULMIU872) is suitable for monitoring a zone of up to 20 UL approved conventional detectors.

H (mm) 65

W (mm) D (mm)

35

18.5

We offer an enclosure for our micro interfaces, see p38.

Features

Ingress protection

ULMCOM/ ULMCOM-S
IP40

ULMCIM/ ULMCIM-C
IP40

ULMIU872 IP40

ULMIU872 IP40

ULBU IP40

Catalogue numbers

Description 4-Way sounder controller unit Shop monitor unit Spur isolator unit 3 Channel input/output unit resets on reset 120V/230V ac relay unit ULMIU872 Micro zone monitor unit
SIGNALING
4AC5

Code ULCSC354 ULCSUM355 ULCSI350 ULCIO351 ULCMIO353 400025FIRE-0054X

Description
ULMCOM Micro single channel output unit (recognised as output unit)
ULMCOM-S Micro single channel output unit (recognised as sounder)
ULMCIM Micro single channel input unit (recognised as input unit)
ULMCIM-C Micro single channel input unit (recognised as callpoint)
Mini module box unit (empty box)

Code 400015FIRE-0060X 400016FIRE-0063X 400013FIRE-0051X 400014FIRE-0057X ULBU

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

59

60

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Contents
Conventional fire systems

Conventional fire system panels

EFCV8 series panel

62 FXP2200 series panel

Conventional systems
Contents

64 CF5000 series panel

66

EFCDP series panel

68

Conventional devices
Detectors and indicators

70 Bases

74 Beam detectors

72

Duct probe detector

75 Callpoints

76 Bells

77

Sounders

78 Visual alarm devices

80 Indicators

82

Sounder indicators

83 Door retainers

84 Auxiliary power supply

85

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

61

Conventional systems
EFCV series

EFCV8Z
Conventional control panel

Eaton's 8 zone conventional fire system panel delivers a straightforward, intuituve interface that makes programming and maintenance simple.

Approved to EN54-2&4, it offers a comprehensive set of functionalities in a modern, robust and discrete enclosure. It's appearance and performance makes the panel well suited for life safety notification in a wide variety of small to medium sized buildings, particularly schools, warehouses, retail stores and office buildings.

With the addition of an isolator barrier the panel has the additional flexibility to monitor standard or
EFCV8ZONE

No. of zones Detectors per zone Maximum loading per zone Repeater Port No. of sounder circuits Maximum loading per sounder circuit Ingress protection

8 32 32mA  4 250mA IP30

intrinsically safe conventional zone circuits, making it suitable for industrial applications.
Benefits · Zones switchable between standard conventional and intrinsically safe zones (using isolator barrier) · One man test facility · Class change input · Interlink relay functionality for connecting 2 panels together · Interlink relay allows for greater system flexibility · Supports an expansion card for Fire Routing Equipment, Fire Protection Equipment and fire relays per zone · Modern and discreet enclosure

62

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Conventional systems
EFCVSeries

Dimensions

Catalogue numbers
Description Eaton 8 Zone Conventional Panel End of Line Module

Code EFCV8Z EOLM-1

Complete Panel Back Box

H (mm) 336 273

W (mm) 375 338

D (mm) 134 88

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

63

Conventional systems
FX2200 series

FX2200CPD series
Conventional control panel

"A flexible conventional solution that ensures ease of use and high reliability"

The FX2200CPD range of conventional control panels provide a solution to any conventional system requirement. The advanced features include a simple "one-shot" user test facility, class change contacts, battery voltage alarms and charger temperature compensation, all included as standard to ensure ease of use and high reliability.
Attention to detail is emphasised by the neat log book holder feature, allowing essential records to be stored close to hand, ready for quick reference. For larger installations, custom configuration of the panels offers even greater flexibility, allowing

project specific requirements to be easily met, in a competitive and cost effective package.
Benefits · Compact design · Surface or semi-flush mounting · Numerical access code (no lost keys) · 2 or 4 zones panels · Flexible, high specification system · Simple "one-shot" auto-reset user test facility · Maintenance free poly switch circuit protection, with auto reset

No. of zones Detectors per zone No. of alarm circuits

FX2202 2 32 2

FX2204 4 32 2

Ingress protection

FX2202 IP30

FX2204 IP30

64

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Compatible Repeater Panel
To complement the FX2200 range a repeater panel is available for connection to the 4 zone control panel. Specifically designed for ease of installation, it requires only 2 interconnecting wires from the main panel, saving material cost and labour time. Further repeater panels can be cascaded which does not affect standby time as each has its own mains supply and standby battery. The repeater displays all the same functions as the main panel and includes an indicator test facility.

Conventional systems
FX2200 series

Features
· Charger with built in temperature compensation
· Displays essential information at other key locations in a large building/site
· Zone fire and fault conditions · Test mode in operation · Zones or alarm lines in disabled mode

Dimensions
D1 W

H

MUTE SCROLL BUZZER
1 23 4 5

Catalogue numbers
Description Conventional 2 Zone Panel Conventional 4 Zone Panel Fire Alarm System Log Book

Code FX2202CPD FX2204CPD MFALOG

D2

H (mm) W (mm) D1 (mm) D2 (mm)

2 / 4 zone panel

270

332

45

47

Cut-out

265

327

-

-

Note: If surface mounting add D1 and D2 to obtain depth dimension

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

65

Conventional systems
CF5000 series

CF5000 series
Conventional control panel

"Contemporary and compact panel design that provides a solution to any conventional system requirement"

The new CF5000 conventional control panel is currently available in a 16 zone version. The panel features an array of user friendly features and are available at very competitive prices. The attractive flush or surface mountable plastic enclosure, with metal back box, has been designed through intensive voice of the customer research to provide ample space for termination of cables.

Benefits · Zonal relay card as standard · One man test facility · Non latching zone feature · Class change input · Fire and fault relays · Discreet enclosure · Supplied complete with battery for 24 hour standby

No. of zones Detectors per zone No. of alarm circuits Zonal relay card Ingress protection

CF50016 16 30 4  IP30

66

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

ION CERTIFI
LPCB

SS PREVENT

CATIO N BOA

RD

LO

Conventional systems
CF5000 series

Dimensions
D1
H1

W2 D2
H2

W1

Description

H1 (mm) Total height

16 Zone

276

W1 (mm) Total width
375

D1 (mm) Total depth
136

H2 (mm)
Back box height 232

W2 (mm) D2 (mm)

Back box width 335

Back box depth
96

Catalogue numbers
Description 16 zone control panel Fire alarm system log book

Code CF50016 MFALOG

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

67

Conventional systems
EFCDP series

EFCDP

NEW PRODUCT

The Eaton Fire EFCDP EN54 compliant conventional panel series is designed to provide simplicity and reliability to end users.
Available with 2, 4 or 8 zones, this easy to install panel provides ease of access through its spacious interior ensuring plenty of room for wiring and battery change. It comes with a 1.25 Amp 27V power supply and includes space for 2 x 3.2 Ah sealed lead acid batteries. Battery management is fully monitored through the system. Fire and fault voltage-free relays and a class change input are included.
Activation of the panel is carried out via access code. The panel features soft tactile colour coded buttons to facilitate control and programing, and is easily tested through one man walk tests ­ reducing maintenance costs for the end-user.

The panel is compliant with European standards EN54-2 & 4, Fire Detection and Alarm Systems - Control & Indicating Equipment, and carries an LPCB mark.
Benefits · Easy to install and maintain · One-man test facility · Compatible with Eaton D200 detector series · Up to 30 detection devices per zone · Secured with code entry for activation of controls · Test with or without sounders in test mode · Ease of programming with colour coded, soft tactile buttons · Modern and compact enclosure

EFCDP

EFCDP

No. of zones Detectors per zone Power supply Monitored sounder outputs

2, 4, 8; EOLR = 6K8 30 Switch mode 1.25A/27Vdc 2

Alarm load Cable entry Max battery size Compliance

68

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

800mA (shared) 13 entries, 20mm diameter knockouts 2 x 3.2Ah, 12V, SLA EN54 Parts 2 and 4
ION CERTIFI
LPCB

SS PREVENT

CATIO N BOA

RD

LO

Conventional systems
EFCDP series

Dimensions

Catalogue numbers

Description EFCDP Conventional Detection Panel 2 zones EFCDP Conventional Detection Panel 4 zones EFCDP Conventional Detection Panel 8 zones

Code EFCDP2Z EFCDP4Z EFCDP8Z

H (mm)

Back Box

235

Lid

235

Total depth (back box + lid fitted)

W (mm) 287 285

D (mm) 60 20 80

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

69

Conventional systems
Devices - detectors and remote indicator

Detectors and remote indicator
The conventional range offers a multi-mode, 5 in 1 detector (FXN922), covering many building needs. It's quick and simple to install with a stylish low profile design. The detector is mounted on our standard conventional base (EFXN520) but can also be used in conjunction with our relay base (FXN520R) for local switching. Each detector is fitted with a 360° viewable LED for indication.
This multi-mode detector can be configured to operate as either an optical detector, photo-thermal detector or 1 of 3 heat detector modes (A1R, BS, CS) using the four position switches located at the back of the detector. The FXN922 is certified for use in all 5 modes.
Compatible with panels EFCV8, FXP2200, CF5000.

Multimode detector FXN922
Base not included. See p74 for compatible bases.

Optical smoke detector mode
Typical applications:
Suitable for most applications.
Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Photo-thermal detector mode
Typical applications:
Responds quickly to fast clean burning fires.
Maintains the advantage of optical sensors when detecting smouldering fires.

Rate of rise heat detector mode
Typical applications:
Environments where the ambient conditions might cause false alarms with smoke detectors.
Examples include areas with high levels of dust or fumes.

Fixed heat detector (77°) mode
Typical applications:
Environments where a change in temperature is a likely occurrence. Using a fixed heat negates false alarms from insignificant temperature rises.

Fixed heat detector (92°) mode
Typical applications:
Environments where the ambient heat levels are likely to be above normal temperatures, such as restaurant kitchens.

Note:
We can also supply separate detectors for each individual mode if they are required. These are displayed in the catalogue numbers in the table over the page.

Remote indicator FX251D

Dimensions
D

Typical applications:
The remote indicator is ideal for applications such as void spaces or outside locked or inaccessible rooms to provide indication of the activation of an automatic detector.

H

W
Description Remote indicator

H (mm) 87

W (mm) 87

D (mm) 49

70

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

ION CERTIFI
LPCB

SS PREVENT

CATIO N BOA

RD

LO

Conventional systems
Devices - detectors and remote indicators

Performance

Feature
Area coverage (subject to local standards) Heat class Alarm temperature

Optical

Photo-thermal Rate of rise

smoke mode mode

mode

100m2

100m2

50m2

Fixed heat 77 °C mode
50m2

Fixed heat 92 °C mode
50m2

N/A

A2S

N/A

60 °C

A1R 60 °C

BS 77 °C

CS 92 °C

Dimensions
Dia

Switch settings

D1 D2

On
On

Description

Diameter (mm) Depth (mm) Depth (mm)

(incl base)

(incl base) (excl base)

Multimode detector* 104

42

55

Optical smoke

104

detector

33

45

* All other conventional detectors share same dimensions

12 34 Off
Description Optical mode Photo-thermal mode Rate of rise mode Fixed heat 77° mode Fixed heat 92° mode
Ingress protection

SW1 -

SW2 OFF OFF ON OFF ON

SW3 OFF OFF OFF OFF ON

SW4 OFF ON OFF ON OFF

5 in 1/EFXN533/ FX251D/CIR301WP EFXN632\EFXN525/ EFXN524\EFXN526

IP40

IP30

Catalogue numbers
Description 5 in 1 Multi-Mode Detector FXN922 Optical Smoke Detector Photo-Thermal Detector Rate of Rise Heat Detector Fixed Heat Detector 77 °C Fixed Heat Detector 92 °C Remote Indicator Weatherproof Remote Indicator

Code 400017FIRE-0031X EFXN533 EFXN533 EFXN525 EFXN524 EFXN526 FX251D CIR301WP

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

71

Conventional systems
Devices - conventional detectors

Detectors for EFCDP panel range
The D200 conventional detector range offers a multipurpose offering for both smoke and heat detection. The range includes optical, heat and multi-sensor detectors suitable for applications within two-wire conventional systems and addressable systems suitable for conventional detectors.
The detectors provide fire detection and alarm system designers with a standard compliant economical product for life safety and property protection.

Optical smoke detector D200-O

Multi-sensor detector D200-HO

Heat detector D200-H

Typical applications:
Suitable for most applications.
Early detection of fire and high immunity against unwanted alarms.

Typical applications:
Ideal for both fast-flaming and slow smouldering fires.
Dual purpose detector to detect smoke, heat or a combination, supported by high immunity against unwanted alarms

Typical applications:
Environments where the ambient conditions might cause false alarms with smoke detectors.
Examples include areas with high levels of dust or fumes.

Performance
Alarm current (max) Alarm response threshold (smoke) Alarm response threshold (heat)

D200-O 40mA N/A
N/A

Dimensions

D200-HO

D200-H

50mA
0.08 - 0.15 dB/m
590c static and rate of rise

50mA 0.08 - 0.15 dB/m
590c static and rate of rise

Dimensions (mm) excluding contacts

Catalogue numbers

Description

Order code

D200-HO two-wire multi-sensor detector 400020FIRE-0034X

D200-O two-wire optical smoke detector 400019FIRE-0033X

D200-H two-wire heat detector

400018FIRE-0032X

Note: products must be ordered in multiples of 8 pcs

72

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

D200-O 102 x 34

D200-HO 102 x 45

D200-H 99 x 45

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

73

Conventional systems
Devices - bases and beam detectors

Bases
There are two types of conventional detector bases, compatible with our range of detector heads to provide a wide functionality for different applications. The standard base (EFXN520) is a general use product, providing a foundation for our conventional detectors, whereas the relay base (FXN520R) provides a local relay signal in the event of its host detector being triggered, making it ideal for instigating a local response.

Note: Bases not compatible with D200 conventional detector range.

Standard base EFXN520

Relay base FXN520R

Typical applications:
General use product, suitable for use in most indoor applications.

Typical applications:
Areas where a local response is required.

Dimensions

D D

Dia
Standard base

Description Standard base Relay base

Dia (mm) 104 102

Dia
Relay base
D (mm) 22 40

Catalogue numbers
Description Standard base Relay base

Code EFXN520 FXN520R

74

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

ION CERTIFI
LPCB

SS PREVENT

CATIO N BOA

RD

LO

Duct probe detector
The presence of smoke in a ventilation duct is detected by sampling the airflow through the duct via two sampling tubes. An optical detector and base are mounted within the sampling chamber, which is located on the external skin of the duct, with sample and exhaust probes passing into the duct in an area of low turbulence.
Duct probe unit MDP201

Conventional systems
Devices - duct probe detector

Typical applications:
Detecting presence of smoke in ventilation ducts.

Duct probe unit shown with optical detector - detector and base must be ordered separately.

Features

Duct width range Duct air speed range
Temperature range Ingress protection
Catalogue numbers
Description Mounting bracket Duct probe unit

300mm to 1500mm 5 to 50 metres 1m/s to 20m/s Detector ± 0.8° Prism ± 5.0° -20°C or +60°C IP67
Code MRBFP MDP201

Duct probe units can be used to detect the presence of smoke in a ventilation duct

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

75

Conventional systems
Devices - callpoints
Callpoints
Two versions of the conventional callpoint are available, the surface or flush mounted FX201 or the weatherproof FX203. Both have an integral short circuit isolator and are very simple to install. The callpoints are packaged with 2 frangible glass elements and test key, with a comprehensive range of further devices available.

Surface/flush mounted Weatherproof callpoint

callpoint

FX203

FX201

Dimensions
W

H

Typical applications:
General use product, suitable for use in most indoor applications.

Typical applications:
Builds requiring a callpoint in harsh conditions. For example, outside or in a wash down area.

D

Description Surface mounted Flush mounted Weatherproof

H (mm) 87 87 87

W (mm) 87 87 87

D (mm) 57 36 59

Features
Fast fit clip Heavy duty terminals Ingress protection

FX201   IP42

FX203   IP65

Further accessories:

Catalogue Numbers

Description

Code

Surface/flush callpoint

FX201

Weatherproof callpoint

FX203

CXPC Protective hinged cover (pack of 10)

CXPC

Spacer plates (pack of 10)

MBGSP

MBGBEZ Recessing bezels (pack of 10)

MBGBEZ

MBGREKIT Resettable element kit (pack of 10) MBGREKIT

FX5G Spare break glasses (pack of 10)

FX5G

MFBGKEY3 Callpoint keys (pack of 10)

MFBGKEY3

Callpoint shown with protective hinged cover
Callpoint recessing bezel

76

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

ION CERTIFI
LPCB

SS PREVENT

CATIO N BOA

RD

LO

Bells
Bells still remain a popular choice for many applications where they can sometimes be used as a signal for non-fire purposes, such as class change in a school.
Internal 6 inch bell FX006

Conventional systems
Devices - bells

Typical applications:
Can be used for non-fire applications, such as class change in a school.
Dimensions
D
Dia

Internal 6 inch bell

Description 6 inch internal bell

Dia (mm) 152

D (mm) 63

Bells can be used for non fire applications such as class change in a school

Sound output
Sound Output

FX006 93-95dB(A) at 24V dc

MWB824 95dB(A) (+/-2)

Features
Ingress protection

FX006 IP21C

Catalogue numbers
Description FX006 Internal 6 inch bell

Code FX006

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

77

Conventional systems
Devices - sounders
Sounders
We have an extensive range of conventional sounders, designed to meet every specification's functional and aesthetic needs. Completely EN54 Pt. 3 certified, each sounder offers a unique solution to your conventional system requirements.

Flush sounder FX003

Surface sounder FX002SB

Weatherproof surface sounder FX002DB

High output wall sounder FX007

Typical applications:
Ideal for retail, hotel and residential applications such as sheltered housing.

Typical applications:
This all-purpose sounder has been designed to be both robust and aesthetically pleasing to meet many build requirements.

Typical applications:
The weatherproof sounder is perfect for harsh weather conditions where a sounder is needed. With selectable tones a high volume can be easily achieved meaning this sounder functions well in outdoor settings.

Typical applications:
With a maximum output of 120dB(a), this sounder is ideal for areas with high ambient noise levels like warehouses.

Low current wall sounder MLC624

Base mountable sounder FXN824

Typical applications:
Designed to provide a high sound output with a low current consumption the MLC624 is perfect for areas where high sound levels need to be achieved but sounder circuit capacity is limited.

Typical applications:
With a slim and aesthetically pleasing design this base sounder is ideal for applications such as hotel bedrooms where a detector/ sounder or a detector/sounderbeacon is required.
Please note a detector base is still required when used in conjunction with a detector

78

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Wall sounder detail

Conventional systems
Devices - sounders

Sound output

FX003

FX002

FX007

MLC624

FXN824

Sound output

98dB(a) at 1 Metre 105dB(a) max (+/-2) 120dB(a) (+/-2)

100dB(a) at 24V dc 80/90dB(a) (+/-3) @

(+/-2)

at 24V dc

Max at 1m (tone 5)

1 Metre

114dB(a) (+/-2) Max at 1m (tone3)

Tones

32

32

32

3

8

Dimensions
W D

D

D

D

Dia

H

D

H

Flush sounder

W
Wall sounder

Description Flush sounder High output wall sounder Low current wall sounder
Features
Ingress protection

H (mm) 86 105 105
FX003/ FX003W IP20

W (mm) 86 105 105

D (mm) 36 95 95

FX002SB IP54

FX002DB IP65

Dia Dia

Surface sounder

Weatherproof surface sounder

Description Surface sounder Weatherproof surface sounder Base mountable sounder

Dia (mm) 93 93 111

Base mountable sounder
D (mm) 63 93 26

Ingress protection

FX007 IP42

Catalogue Numbers

MLC624 IP30

FXN824 IP65

Description Flush sounder, red Flush sounder, white Low profile surface sounder, red Weatherproof deep base surface sounder back box, red (IP65) High output wall sounder Low current wall sounder Base mountable sounder Blanking plate for FXN824 (pack of 5) Deep base for surface sounder (IP65)

Code FX003 FX003W ROLP-R-S ROLP-R-D
FX007 650001FULL-0003X FXN824 MDS824COV FX000WP

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

79

Conventional systems
Devices - EN54-23 visual alarm devices

Visual alarm devices (VADs)

From 31st December 2013 a new beacon standard, EN 54-23 became mandatory throughout the EU where Construction Product Regulation (CPR) applies. It directly affects the use of visual alarm devices (VADs) in fire detection and alarm systems for non-domestic premises. Its purpose is to standardise the requirements, test methods and functional criteria of VADs to ensure that their visual performance is measured and presented in a uniform manner.
Eaton's LX range has been designed to comply with the new EN 54-23 standard. With current consumption as low as 10mA, the range has been developed to provide the lowest current consumption with the highest possible coverage. Three years in the making, the LX range, available for wall and ceiling applications, features a number of patented technologies including an innovative lens and flash pattern.

Solista LX wall FXSOLWRS
1Hz FLASH
Typical applications:
With both a shallow base and deep base option the Solista meets requirements of a large range of builds.

Solista LX ceiling FXSOLCWS
1Hz FLASH
Typical applications:
The ceiling option Solista helps to cover different types of room sizes to meet the requirements of the CoP 0001 design guidelines.

RoLP LX wall FXROLPWR

Symphoni LX wall FXSYG1WR

Symphoni LX WP wall (weatherproof) FXSYG1WR-WP

These products are all red flash, for more options please contact:
firetechsupport@eaton.com

1Hz FLASH

1Hz FLASH

1Hz FLASH

Typical applications:
The RoLP LX Wall is ideal for dual use applications where a visual alarm device is required in addition to an audible alarm.
The RoLP LX Wall is available to use with any standard RoLP sounder.

Typical applications:
The Symphoni LX Wall base can be used in combination with any standard Symphoni sounder.
Its high sound output makes it suitable for open areas or areas where there is higher than normal background noise.

Typical applications:
The Symphoni LX WP Wall device offers a weatherproof alternative to the Symphoni LX Wall device. With an ingress protection rating of IP66, it is suited for wet and outdoor environments.

Performance

Solista LX wall

Sound output

N/A

Minimum current consumption EN54-23 coverage reference Coverage volume Flash rate
Ingress protection

10mA W-2.4-7.5 135m3 (15m3) 1Hz (switchable to 0.5Hz) IP33C

Solista LX ceiling
N/A
10mA C-3-7.5 132m3 (21m3) 1Hz (switchable to 0.5Hz) IP33C

RoLP LX wall
102dB(A) (Typical tone 3 - RoLP) 22mA W-2.4-7.5 135m3 (15m3) 1Hz (switchable to 0.5Hz) IP65

Symphoni LX wall
100dB(A) (Typical tone 3 - Symphoni) 15mA W-2.4-7.5 135m3 (15m3) 1Hz (switchable to 0.5Hz) IP21C

Symphoni LX WP wall
100dB(A) (Typical tone 3 - Symphoni) 15mA W-2.4-7.5 135m3 (15m3) 1Hz (switchable to 0.5Hz) IP66

80

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Conventional systems
Devices - EN54-23 visual alarm devices

Dimensions
9D3mima

93mm

D9i3amm

93mm

W95mm
135mm
H

135mm

95mm

SHALLOW BASE DEEP BASE

SHALLOW BASE

DEEP BASE

D

D

D

D

D

Solista LX wall
W

Solista LX ceiling
W

RoLP LX wall

H

D D

Symphoni LX wall

H
Symphoni LX WP wall

Description Solista LX wall deep base Solista LX wall shallow base Solista LX ceiling shallow base RoLP LX wall Symphoni LX wall Symphoni LX WP wall

Dia (mm) 93 93 93 -

D (mm) 66 38 37 95 92 92

W (mm) -
95 106 106

H (mm) -
135 147 147

Catalogue numbers
Description Solista wall red body shallow base Solista wall red body deep base Solista LX ceiling RoLP wall red body base and sounder RoLP wall red body base only Symphoni LX wall red body Symphoni LX wall weatherproof red body

Code FXSOLWRS FXSOLWRD FXSOLCWS FXROLPWR FXROLPWR-B FXSYG1WR FXSYG1WR-WP

Description
DeeFpobrasme foorrSeoligstauLidX acenilicnge on EN-54-23 and placement of VADs, refer to our Fire Installer's Mate pocket guide.

Code
cc2478 Fire Systems & VADs Design Guide.qxp_Layout 1 12/02/2014 09:37 Page 1
FX000WWP Fire Systems Design Pocket Guide
BS 5839 Part 1:2013 and CoP 0001 for Visual Alarm Devices
Fire Installers Mate
A guide to fire system design

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

81

Conventional systems
Devices - indicators

Indicators
In areas which do not have to meet the new regulations regarding EN54-23 visual alarm devices, our range of indicators can still provide reliable light indication.

Low profile LED indicator MLB124SB

Weatherproof LED indicator MLB124DB

Typical applications: Typical applications:

In regions where the EN5423 VADs standard is not a requirement, the LED indicator can be used as an indicating device.

The weatherproof version of the LED indicator provides an IP65 option ideal for outdoor use.

Dimensions

D D

Dia
Low profile LED indicator

Dia
Weatherproof LED indicator

Description Low profile LED indicator Weatherproof LED indicator

W (mm) 95 95

D (mm) 53 80

Note: From 31st December 2013 a new beacon standard, EN 54-23 became mandatory across Europe where Construction Product Regulation (CPR) applies. If you are in a region where this standard applies please understand that these indicators do not meet the requirements of the new standards - see p80 for compliant beacons and sounder beacons

Features
Ingress protection

MLB124SB IP54

MLB124DB IP65

Catalogue numbers
Description Low profile LED beacon Weatherproof LED beacon

Code MLB124SB MLB124DB

82

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Conventional systems
Devices - sounder indicators

Sounder indicators
In areas which do not have to meet the new regulations regarding EN54-23 visual alarm devices, our range of sounder indicators can still provide excellent sound quality and light indication.

Xenon sounder

Weatherproof Xenon

indicator

sounder indicator

Dimensions

FL-RL-R-S

FL-RL-R-D

D

D

Dia
Xenon sounder indicator

Typical applications:
In regions where the EN5423 VADs standard is not a requirement, the xenon sounder indicator provides an alternative option to the xenon indicator - where an audible warning is required in addition to light indication.

Typical applications:
The weatherproof version of the sounder indicator is IP65 rated which allows for installation in harsher environments.

Description Xenon sounder indicator Weatherproof xenon sounder indicator

Dia
Weatherproof xenon sounder indicator

Dia (mm) 93 93

D (mm) 92 121

Sound output

XENON sounder indicator, FL-RL-R-S/FL-RL-R-D

Sound output

101dB(a) at 24V dc (typical tone 3)

Tones

32

Features
Ingress protection

FL-RL-R-S IP54

FL-RL-R-D IP65

Note: From 31st December 2013 a new beacon standard, EN 54-23 became mandatory across Europe where Construction Product Regulation (CPR) applies. If you are in a region where this standard applies please understand that these indicators do not meet the requirements of the new standards - see p80 for compliant beacons and sounder beacons

Catalogue numbers
Description Conventional xenon sounder indicator Weatherproof IP65 xenon sounder indicator

Code FL-RL-R-S FL-RL-R-D

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

83

Conventional systems
Devices - door retainers and relay unit
Door retainers and relay unit
Door retainers enable doors to be held open under normal conditions but automatically be released in the event of fire alarm activation. Eaton have a range of door retainers which are robust and simple to install. Both floor and wall mounted retainers, with either mains or 24V dc power supplied variations, are available.

Heavy duty door retainer MDR240/MDR24L

Compact door retainer Heavy duty relay unit

FX021240LC/

MAR724

FX02124VLC

Typical applications:
Robust and simple to install, the heavy duty door retainer is ideal for a wide range of applications, such as nursing homes, hospitals, schools and industrial premises.

Typical applications:
Equally as reliable, the compact door retainer is also a good choice for nursing homes, hospitals and also busy corridors.

Typical applications:
Designed for interfacing heavy loads such as door release units or plant shut down equipment with fire alarm systems.
This unit is simple to fix and install and the neat unobtrusive design makes it suitable for use in a wide range of areas.
The heavy duty relay unit is powered by 24V dc external supply and is provided with 2 separate sets of changeover contacts.
Can switch 230V ac mains at 10A

Performance

Holding force
Power consumption
Ingress protection

MDR240 MDR24L FX021240LC FX02124VLC

40kg

40kg

45kg

40kg

1.2VA

40mA

1.2VA

40mA

IP40

IP40

IP42

IP40

Catalogue numbers
Description Mains powered heavy duty door retainer 24V dc heavy duty door retainer Floor mounting bracket for heavy duty door retainers Mains powered compact door retainer 24V dc compact door retainer Floor mounting bracket for compact door retainers Spare striker plate for either magnet Heavy duty relay unit

Code MDR240 MDR24L ZMDRFBB FX021240LC FX02124VLC FX021LCFB ZMDRSWIV MAR724

84

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Power supply
Specifically recommended as an auxiliary power supply unit for fire detection system components such as electromagnets, notification devices, etc. Using the unit in large systems eliminates the problem of long power cable runs which simplifies installation.
EN54 pt.4 approved power supply unit SPS Range

Conventional systems
Devices - power supply

Typical applications:
The new range of EN 54-4 certified safety power supplies offer a compact, robust and versatile power solution to installers, allowing them to safely power fire detection and signaling systems in small to large installations.
Compact and discrete design allows for these SPS to be installed in a visible location such as a hotel lobby for instance. Comprehensive yet simple status indicators on the front of the unit help installers, commissioners and maintainers assess status of the unit.

Features
Ingress protection

SPSS-2423/2433/2453 IP30

Catalogue numbers
Description Safety power supply 24V / 1.5A (batteries not supplied) Safety power supply 24V / 2.5A (batteries not supplied) Safety power supply 24V / 4.5A (batteries not supplied)

Code SPS-2423 SPS-2433 SPS-2453

Door retainers enable doors to be held open under normal conditions but automatically be released in the event of fire alarm activation.

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

85

86

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Notes

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

87

Introduction
Section Name

Spring Mews London, UK

88

EATON - FIRE SYSTEMS AND DEVICES CF-CC2556 August 2019

Contact details
Sales and technical support

Contact
Eaton
Eaton Electrical Systems Ltd Wheatley Hall Road Doncaster South Yorkshire DN2 4NB United Kingdom www.cooperfire.com www.eaton.com

Sales
T: +44 (0)1633 628 566 F: +44 (0)1302 367 155 E: FireCustomerService@eaton.com

Service
T: +44 (0)1302 303 352 F: +44 (0)1302 303 332 E: FireService@eaton.com

Technical
T: +44 (0)1302 303 350 F: +44 (0)1302 303 332 E: FireTechSupport@eaton.com

Export
T: +44 (0)1302 303 344 F: +44 (0)1302 303 345 E: FireExport@eaton.com

Online Resources
Visit www.eaton.com for the following resources:
· 24/7 online product support · Catalogue and literature · Product profiles · Datasheets, installation and
user manuals

EATOENA-TOFINRE- AFINRDE VAONIDCEVOAILCAERAMLASRYSMTESMYSSTE20M1S4 CF-CC2556 June 20147

89

At Eaton, we're energized by the challenge of powering a world that demands more. With over 100 years experience in electrical power management, we have the expertise to see beyond today. From groundbreaking products to turnkey design and engineering services, critical industries around the globe count on Eaton.
We power businesses with reliable, efficient and safe electrical power management solutions. Combined with our personal service, support and bold thinking, we are answering tomorrow's needs today.
Follow the charge with Eaton, visit eaton.eu

UAE Middle East Headquarters Techno Park, Jebel Ali (South) P.O Box 261768 Dubai, United Arab Emirates Tel: +971 4 8066100 Fax:+971 4 8894813

Kuwait Shayma Tower, Mezzanine Floor Omar Bin al Khattab Street Sharq Kuwait Tel: +965 22253606 Fax:+965 22253608
Saudi Arabia King Abdullah Street (Ex. Dhahran St.) Dhahran Centre, 1st Floor Office 101 P.O Box 620 Al-Khobar 31952, Saudi Arabia Tel: +966 1 38825424 / 8825680 Fax:+966 1 38825732
Saudi Arabia Saad Al-Ajlan Trade Centre 1st Floor Office 9, Olaya Main Stret P.O Box 19651 Riyadh 11445, Saudi Arabia Tel: +966 1 4602275 / 288-6238 Fax:+966 1 14602291
Eaton Electrical Sector EMEA Route de la Longeraie 7 1110 Morges, Switzerland
Eaton Eaton Electrical Systems Ltd. Wheatley Hall Road Doncaster South Yorkshire DN2 4NB United Kingdom
Tel: +44 (0)1302 303 999 Fax: +44 (0)1302 303 333 Email: FireSales@eaton.com Web: www.cooperfire.com
www.eaton.com
© 2019 Eaton All Rights Reserved Pub Reference: CF-CC2556 August 2019

Lebanon Sin El Fil, Saydet Al Wardiyeh Street Beirut Symposium Building 2nd Floor, Office 2A Tel/Fax: +961 1 494711

Oman Maktabi building, Office No 208 Near Zakher Mall, Al Khuwair PO Box 1982, PC 111 CPO Oman Tel: +968 24391973 Fax:+968 24483801

Qatar Greedco 1 Building, Office no 4303 PO Box 91357, C Ring Road Doha, Qatar Tel: +974 4467273 Fax: +974 44667134

Egypt Building No. 289 Off 90th Street Apartment 4B, 4th Street 5th District, New Cario, Egypt Tel: +202 261 357 47
+202 261 357 46

Jordan Amman-Mekkia & Madina Streets Intersection Al-Haramien intersection. Al Hajar Al Aswad Cplx, 3rd floor - Office 306 Tel: +962 6 5542538

Iraq Burosan Bldg, 4th Floor, Office 10 60m Street, Kouran Intersection Erbil, Iraq


Adobe PDF Library 15.0 Adobe InDesign CC 2017 (Windows)