Illustrated Parts List TACO BELL DuAL-LINE COuNTER

Illustrated Parts Lists for Taco Bell Dual-Line Counter 8/23/2017 4 IPL-PF-TB-0027 Table: PL-1 Tri-Channel Cold Pan TRI-CHANNEL COLD PAN ITEM QTY.

Parts Manual

Duke Worktable, Shelf, & Transport Cart Parts | Parts Town Mexico

DUK-TBDLCOUNTER pm ?v=1586234091050
Illustrated Parts List

TACO BELL Dual-LINE COUNTER
ON O OFF

This manual is Copyright © 2017Duke Manufacturing Co. All rights reserved. Reproduction without written permission is prohibited. Duke is a registered
trademark of the Duke Manufacturing Co.
Duke Manufacturing Co.
2305 N. Broadway · St. Louis, MO 63102 800.735.3853 · 314.231.1130
Fax: 314-231-5074 www.dukemfg.com
IPL-PF-TB-0027

8/23/2017

Illustrated Parts Lists for Taco Bell Dual-Line Counter
TABLE OF CONTENTS
HOW TO DETERMINE MANUFACTURE DATE FROM DUKE EQUIPMENT SERIAL NUMBERS.................................................................................3
TRI-CHANNEL COLD PAN..................................................................................................................4 Table: PL-1 Tri-Channel Cold Pan.............................................................................................4 Figure: PL-1 Tri-Channel Cold Pan............................................................................................5
REFRIGERATED BASE UNIT..............................................................................................................6 Table: PL-2 Refrigerated Base Unit............................................................................................6 Figure: PL-2 Refrigerated Base Unit..........................................................................................7
DRY CHANNEL WARMER...................................................................................................................8 Table: PL-3 Dry Channel Warmer ..............................................................................................8 Figure: PL-3 Dry Channel Warmer ............................................................................................9
DRY CHANNEL RELAY BOX ASSEMBLY.........................................................................................10 Table: PL-4 Dry Channel Relay Box Assembly.........................................................................10 Figure: PL-4 Dry Channel Relay Box Assembly.......................................................................11
DRY CHANNEL RELAY BOX ASSEMBLY REV 5.1...........................................................................12 Table: PL-5 Dry Channel Relay Box Assembly Rev 5.1...........................................................12 Figure: PL-5 Dry Channel Relay Box Assembly Rev 5.1..........................................................13
DRY CHANNEL CONTROL BOARD..................................................................................................14 Figure: PL-6 Dry Channel Control Board..................................................................................14

8/23/2017

2

IPL-PF-TB-0027

Illustrated Parts Lists for Taco Bell Dual-Line Counter

How to Determine Manufacture Date from Duke Equipment Serial Numbers

All units currently manufactured in St. Louis and Sedalia, Missouri (After 2/1/2013):
08 03 0202

Month Manufactured Year Manufactured
(Example: 08030202 = Indicates the unit was manufactured in August of 2003)

Sequential Number

Units Manufactured in St. Louis, Missouri (Before 2/1/2013):
30 IF AA 0123

Unit Identification 10 = 5/9 20 = 6/13 & E-Series 30 = 6/18 & 3/9 90 = FBB 94 = FWM 95 = IRHU 99 = Dry Channel

Year of Manufacture

A= 1

B = 2

C = 3

D= 4

(Examples)

E = 5

(JJ = 2000)

F = 6

(JA = 2001)

G= 7

(JB = 2002)

H= 8

I =9

J =0

Sequential Number
Month of Manufacture JA = January JB = February JC = March JD = April JE = May JF = June JG = July JH = August JI = September AJ = October AA = November AB = December

IPL-PF-TB-0027

3

8/23/2017

Illustrated Parts Lists for Taco Bell Dual-Line Counter

ITEM

QTY.

1

1

2

1

3

1

4

1

5

1

1

6

1

7

1

8

2

9

1

10

2

11

2

Not Shown 1

Not Shown 1

Not Shown 1

Not Shown A/R

Not Shown 1

Not Shown 2

Not Shown 1 Not Shown 2

TRI-CHANNEL COLD PAN

PART NUMBER

DESCRIPTION

216380 216879 217811 217810 217812 212450 216837 216600 212288 551072 550468 553393 216986 550093 216386 216414 216864 214728 553085 550964 216702 551075

Condensing Unit, 120VAC, 60Hz, 1/3 HP Condensing Unit, 120VAC, 60Hz, 1/3 HP, TXV Motor, Electric Fan 120VAC Fan Bracket Fan Blade Tri-Channel Control, Temperature TXV Thermostat, effective after 04/08 Cap Tube .093OD X 0412ID (10') Switch, Tri-Channel Main Power Rail Assembly, Taco ­ Before 05/07 Rail Assembly, Taco ­ After 05/07 Assembly, Wrapper Bins Rack, Vertical Bottle Assembly, Louvered Panel Valve, AVX, I-Line Dryer, TXV TXV Valve. 54 PSI, Adjustable Taco Rail Pin Switch Mounting Plate, 9.5" x 9.5" J-Hook, Sanitizer AXV Valve, Dual Line Scrap Tray, Taco Assembly Rail

8/23/2017

Table: PL-1 Tri-Channel Cold Pan 4

IPL-PF-TB-0027

Illustrated Parts Lists for Taco Bell Dual-Line Counter
TRI-CHANNEL COLD PAN

IPL-PF-TB-0027

Figure: PL-1 Tri-Channel Cold Pan 5

8/23/2017

Illustrated Parts Lists for Taco Bell Dual-Line Counter

ITEM

QTY.

1

1

2

1

3

1

4

1

5

1

6

2

7

2

8

6

9

4

10

6

11

2

12

2

13

2

14

1

15

12

16

16

17

1

Not Shown 16

REFRIGERATED BASE UNIT

PART NUMBER

DESCRIPTION

214947 071136 COLD-KIT 550326 550328 550327 550329 216645 216636 550081 251420 214556 216737 216736 550313 550087 213091 212610 216675 212611

Filter, 9.375x9.875x.3125 Unit Cond. 1/5 HP R-134A 120V 60 Hz Thermostat, Refrigerated Base Control Door, Insulated, 19" LT Door, Insulated, 17" LT Door, Insulated, 19" RT Door, Insulated, 17" RT Gasket, Door 17" Gasket, Door 19" Assembly, Shelf Pilaster Hinge, Base Leg, 6" Adj. mount plate Wire Rack, 19" Opening Wire Rack, 17" Opening Pilaster, Mount Filler Evaporator Cover Thumb Screws Shelf, Clip Temperature, Digital Display Support Pin

8/23/2017

Table: PL-2 Refrigerated Base Unit 6

IPL-PF-TB-0027

123

Illustrated Parts Lists for Taco Bell Dual-Line Counter
REFRIGERATED BASE UNIT
17 4 5 6 7
38 F

38 F

15 14

8 11 13

12 16

9 10

Figure: PL-2 Refrigerated Base Unit

IPL-PF-TB-0027

7

8/23/2017

Illustrated Parts Lists for Taco Bell Dual-Line Counter

ITEM
1 1 1 1 1 1

PART #
553415 553459 553262 553263 553417 553505

2

553411

2

553246

2

553412

Not Shown 228930 Not Shown 228931

3

553414

3

553458

3

553284

3

553291

3

553268

3

553290

4

212792

5

553443

5

553484

5

553289

5

553271

5

553444

Not Shown 553546 Not Shown 553535 Not Shown 553510

Not Shown Not Shown Not Shown Not Shown

553512 553511 551148 218985

DRY CHANNEL WARMER

DESCRIPTION
Tub Assy, 3 Chnl, Single Zn, Dry Chnl Tub Assy, 3 Chnl, Single Zn, Generic, Rev 5.1 Tub Assy, 4 Chnl, Dual Zn, Dry Chnl, Rev 5.1 Tub Assy, 6 Chnl, Dual Zn, Dry Chnl, Rev 5.1 Tub Assy, 6 Chnl, Single Zn, Dry Chnl, Rev 6.1 Tub Assy, 6 Chnl, Single Zn, Generic Dry Chnl

HDC3 X X

Top, 3 Channel, Dry Channel

X

Top, 4 Channel, Dry Channel

Top, 6 Channel, Dry Channel

Gasket, Dry Channel, 3 Channel

X

Gasket, Dry Channel, 6 Channel

Center Chnl, Single Zn, 3/6 Dry Chnl, Rev 6.1

X

Generic Chnl, Single Zn, 3/6 Dry Chnl, 5.1 & Generic

X

Front Chnl, Dual Zn, 4 Chnl, Dry Chnl, Rev 5.1

Kit, Dual Zn, Center Channel Retrofit

Front Chnl, Dual Zone, 6 Dry Channel, Rev 5.1

Kit, Dual Zn, Center Channel Retrofit

Toggle Switch, 30 Amp, Red

X

Relay Box, w/Switch, Dry Channel, Single Zn

X

Relay Box, No Switch, Dry Channel, Single Zn

X

Relay Box, w/Switch, Dry Channel, Rev 5.1

Relay Box, w/Switch, Dry Channel, Rev 5.1

Relay Box, w/Switch, Dry Channel, Single Zn

Kit, Element, 700 Watt, Single Zone

X

Kit, Element, 850 Watt, Dual Zone

Kit, Element, 700 Wat, Dual Zone

Kit, High Limit Replacement

X

Kit, RTD Replacement

X

Ground Bar

X

cable, Grounding

X

HDC4 X
X
X X
X
X
X X X X X

HDC6
X X X
X
X X X
X X X
X X X X X X X X

Table: PL-3 Dry Channel Warmer

8/23/2017

8

IPL-PF-TB-0027

Illustrated Parts Lists for Taco Bell Dual-Line Counter

Dry Channel WARMER

2

31

3

PROG
ON O OFF

45

IPL-PF-TB-0027

Figure: PL-3 Dry Channel Warmer 9

8/23/2017

Illustrated Parts Lists for Taco Bell Dual-Line Counter

ITEM

QTY.

1

1

2

1

3

6

4

1

5

13

6

1

7

1

8

1

9

1

10

1

11

1

12

1

13

1

14

1

15

1

16

1

17

2

18

1

19

1

20

1

Not shown 1

Not Shown 1

DRY CHANNEL RELAY BOX ASSEMBLY

PART NUMBER

DESCRIPTION

553075 553154 218828 218817 213032 553466 218829 213403 147351 171215 213216 218805 171171 218819 218820 404886 218830 218875 553202 553203 218812 553385

Box, Relay with Switch Plate, Relay Mounting Relay, Mini No 20A-240V-24V Mylar, Relay Box Screw 8 X 1/2" TEK PHIL Switch, Lighted, DPST 16GA @ 125V Transformer, 208/240V Pri, 24V Sec Stud PEM 8-32 X 1/2" SS Nut Hex 8-32 HZ-T KEPS Cable, Assembly Power Supply Nutsert, 8-32 Terminal Block Top, Relay Box Wiring Diagram Label, Relays 8-32 X 1/2" RD HD PHIL SS Screw, Connector Harness, DSUB Relay Angle, Mounting Bracket, Left Angle, Mounting Bracket, Right Harness, Terminal Block Kit, Dry Channel retrofit

8/23/2017

Table: PL-4 Dry Channel Relay Box Assembly 10

IPL-PF-TB-0027

Illustrated Parts Lists for Taco Bell Dual-Line Counter
DRY CHANNEL RELAY BOX ASSEMBLY

13

16

14

7

10

15 12
5 11
3 8
18 20
17

19

DANGER

6421

IPL-PF-TB-0027

Figure: PL-4 Dry Channel Relay Box Assembly 11

8/23/2017

Illustrated Parts Lists for Taco Bell Dual-Line Counter

DRY CHANNEL RELAY BOX ASSEMBLY REV 5.1

Item Qty. Part Number

Description

1

1

2

1

3

6

4

1

5

1

6

1

7

1

8

1

9

1

10

1

11

2

12

1

13

1

1

14

12

15

4

16

4

17

13

18

2

19

1

20

1

21

1

22

1

Not Shown 1

553286 553256 218828 218805 218829 553202 553203 213403 218902 553257 218904 218918 218917 228822 213166 213196 154458 213032 213427 218963 218965 218946 218819 228883

Box, Relay with Switch Plate, Relay Mounting Relay, Mini No 20A-240V-24V Terminal Block Transformer, 208/240V Pri, 24V Sec Angle, Mounting Bracket, Left Angle, Mounting Bracket, Right Stud PEM 8-32 X 1/2" SS Terminal Block Top, Relay Box Bushing, HEYCO 1217 Harness, HD15 for RTD's Dry Channel Hardware Harness, DSUB9/Relays for Dry Channel Hardware Harness, Relay 6 Channel Single Zone Unit Pop Rivit 5/32 X 1/8 SS Screw, 8-32 X 1/2" PAN PHIL Nut Hex 8-32 HZ-T KEPS Screw 8 X 1/2" TEK PHIL Screw 4-40 X 1/2" FPPH Switch, Toggle NKK 25 Amp Plate, ON ­ OFF 12MM Conduit, Assembly Power Supply Relay Box Hardwired Wiring Diagram Harness, Wire HDC Term. Block Hardware Single Zone

8/23/2017

Table: PL-5 Dry Channel Relay Box Assembly Rev 5.1

12

IPL-PF-TB-0027

Illustrated Parts Lists for Taco Bell Dual-Line Counter
DRY CHANNEL RELAY BOX ASSEMBLY REV 5.1

Figure: PL-5 Dry Channel Relay Box Assembly Rev 5.1

IPL-PF-TB-0027

13

8/23/2017

Illustrated Parts Lists for Taco Bell Dual-Line Counter
Dry Channel Control Board

PART NO. 553386 228888 228881

Figure: PL-6 Dry Channel Control Board description Kit, Dual Zone Control Board, Retrofit Control Board, Single Zone, 3 Channel Control Board, Single Zone, 6 Channel

553531 553532 553533

Kit, Mylar Replacement, Dual Zone Control Board Kit, Mylar Replacement, Single Zone Control Board, 3 Channel Kit, Mylar Replacement, Single Zone Control Board, 6 Channel

8/23/2017

14

IPL-PF-TB-0027

Notes:

Illustrated Parts Lists for Taco Bell Dual-Line Counter

IPL-PF-TB-0027

15

8/23/2017

Illustrated Parts Lists for Taco Bell Dual-Line Counter

8/23/2017

Duke Manufacturing Company
2305 N. Broadway · St. Louis, MO 63102 800.735.3853 · 314.231.1130
Fax: 314-231-5074 www.dukemfg.com

16

IPL-PF-TB-0027


Adobe InDesign CS6 (Windows) Adobe PDF Library 10.0.1