Slope (refer to instructions for installation of housing and trim) H347 = 347 to 120V step down transformer, 75VA H347200 = 347 to 120V step down transformer, 200VA WTA=Field installed WaveLinx tile mount sensor Kit 1, 5 ... April 6, 2021 4:30 PM. 4000 * narrow. WaveLinx Lite WaveLinx Lite
April 6, 2021 4:30 PM. Top Product Features ... Slope (refer to instructions for installation of housing and trim). H347 = 347 to 120V step down transformer, 75VA.
Slope (refer to instructions for installation of housing and trim) H347 = 347 to 120V step down transformer, 75VA ... April 6, 2021 4:30 PM. PS517016EN April 6, 2021 ...
File Info : application/pdf, 10 Pages, 2.10MB
Document DocumentProject Prepared by Catalog # Notes Type Date HC6 | HM6 | 61 | 61PS High Lumen 6-inch LED new construction/remodel regressed lens downlight and wall wash Low Lumen Typical Applications Office · Healthcare · Hospitality · Institutional · Mixed-Use/Retail Interactive Menu · Order Information page 2 · Product Specifications page 4 · Photometric Data page 5 · Energy & Performance Data page 8 · Connected Systems page 9 · Product Warranty Product Certification Product Features Top Product Features · New construction/remodel series; 1,000 to 4,000 lumens · Narrow, Medium and Wide distributions; Wall wash with rotatable linear spread lens · 2700K, 3000K, 3500K and 4000K CCT; 80 or 90 CRI · Universal voltage 120V-277V; Standard 0-10V driver dims to 1% · Two retrofit kits install from below ceiling for LED upgrades Dimensional and Mounting Details 26.4" [670.56mm] NEW CONSTRUCTION - HIGH LUMEN 3000 AND 4000 LUMEN max module height (see table) LED height (see table) 3.42" [86.77mm] (driver height) 8.6" [217.35mm] .5" [12.70mm] (ceiling thickness) NEW CONSTRUCTION - LOW LUMEN 1000, 1500, AND 2000 LUMENS max module height (see table) 4.2" [107.34mm] hanger bar bracket height (removable) L(apsEeDdreohtdaedbiigltehu)itoc(d[8ntri6va3d.e7.r4l7ih2ame"iggmhr]t)ams .5" [12.70mm] (ceiling thickness) PS517016EN page 1 April 6, 2021 4:30 PM Order Information Sample Number: HC620D010REM7 HM612835 - 61MDC A complete luminaire consists of a housing frame, LED module, and reflector (ordered separately) HC6 | HM6 | 61 | 61PS Mounting Frame Lumens Input / Control Factory Installed Options Accessories Mounting Frame Lumens Input / Control Factory Installed Options Accessories HC6 = 6" new construction and remodeler housing HC6CP = 6" new construction and remodeler housing, CCEA Chicago Plenum rated 10 = 1000 lumens (nominal) 15 = 1500 lumens (nominal) 20 = 2000 lumens (nominal) 30 = 3000 lumens (nominal) 40 = 4000 lumens (nominal) D010=120-277VAC 50/60Hz 0-10V analog 1% - 100% dimming D010347 = 347VAC 50/60Hz 0-10V analog 1%-100% dimming (Canada only) 1 REM7 = 7 watt emergency module with remote test / indicator light, use with D010 only 1 REM14 = 14 watt emergency module with remote test / indicator light, use with D010 only 1 IEM7 = integral 7 watt emergency module with integral test / indicator light, use with D010 only 1 IEM14 = integral 14 watt emergency module with integral test / indicator light, use with D010 only 1 BOD7ST = 7.5 watt Bodine self-test diagnostic emergency module with remote test / indicator light, use with D010 only (1) WTA=Factory installed WaveLinx tile mount sensor Kit(1) (5) WTK = Factory installed WaveLinx Lite Sensor Kit (1) (6) HB128APK = L channel hanger bar, 26", pair (replacement) RMB22 = Adjustable wood joist mounting bars, pair, extend to 22" long HSA6=Slope Adapter for 6" Aperture Housings, Specify Slope (refer to instructions for installation of housing and trim) H347 = 347 to 120V step down transformer, 75VA H347200 = 347 to 120V step down transformer, 200VA WTA=Field installed WaveLinx tile mount sensor Kit 1, 5 WTK = Field installed WaveLinx Lite Sensor Kit (1) (6) Notes Notes DLV = Distributed Low Voltage driver, 1%-100% dimming DLV for use with DLVP system only. Refer to DLVP low-voltage power module and DLVP specifications for details.(1) Notes (1) Not available with CP version REMV7 = 7 watt emergency module with remote test / indicator light, use with DLV only 1, 2 REMV14 = 14 watt emergency module with remote test / indicator light, use with DLV only 1, 2 IEMV7 = integral 7 watt emergency module with integral test / indicator light, use with DLV only 1, 2 IEMV14 = integral 14 watt emergency module with integral test / indicator light, use with DLV only 1, 2 Notes (1) Not available with CP version (2) ULus for U.S. only (5) WTA = WaveLinx tile mount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS - Real Time Location Services, use with D010 only (Refer to WaveLinx system specifications) (6) WTK = WaveLinx Lite tile mount sensor kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to WaveLinx Lite system specifications) Notes (1) Not available with CP version (5) WTA = WaveLinx tile mount sensor kit for daylight dimming, PIR motion sensing, and optional RLTS - Real Time Location Services, use with D010 only (Refer to WaveLinx system specifications) (6) WTK = WaveLinx Lite tile mount sensor kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to WaveLinx Lite system specifications) LED Module LED Module HM6 = 6" LED module Notes Lumens Lumens 12=1000, 1500 and 2000 lumens (nominal), use with HC610*, HC615*, HC620* housings 34=3000 and 4000 lumens (nominal), use with HC630*, HC640* housings Notes CRI/CCT CRI/CCT 827 = 80 CRI (minimum), 2700K CCT 830 = 80 CRI (minimum), 3000K CCT 835 = 80 CRI (minimum), 3500K CCT 840 = 80 CRI (minimum), 4000K CCT 927 = 90 CRI (minimum), 2700K CCT 930 = 90 CRI (minimum), 3000K CCT 935 = 90 CRI (minimum), 3500K CCT 940 = 90 CRI (minimum), 4000K CCT Notes Reflector Reflector 61 = 6" conical reflector Notes Baffle Baffle 61 = 6" baffle reflector Notes Distribution Distribution3 ND = narrow 55° beam angle 0.97 SC MD = medium 60° beam angle 1.10 SC WD = wide 65° beam angle 1.28 SC RWW = rotatable wall wash with linear spread lens Finish Finish C = Specular clear H = Semi-specular clear W = White Notes (3) Values are nominal, with specular clear reflector, other finishes and field results may vary. Notes Flange Flange Accessories Accessories Blank = Polished flange standard with C & H reflectors Blank = White flange standard with W reflector WF = White flange option available with C & H reflectors 61RWWPK = rotatable wall wash insert for 6" reflector replacement part kit Notes Notes Distribution Finish Distribution3 Finish WD = wide 65° beam angle 1.28 SC (nominal) RWW = rotatable wall wash with linear spread lens BB = Black baffle WB = White baffle Notes (3) Values are nominal, with specular clear reflector, other finishes and field results may vary. Notes Flange Flange Blank = White flange standard with BB, & WB BF = Black flange option available with BB Notes Accessories Accessories 61RWWPK = rotatable wall wash insert for 6" reflector replacement part kit Notes PS517016EN page 2 April 6, 2021 4:30 PM Order Information HC6 | HM6 | 61 | 61PS IEM Reflector IEM Reflector 61 = 6" IEM reflector for integral emergency only Distribution Distribution3 ND = narrow 55° beam angle 0.97 SC MD = medium 60° beam angle 1.10 SC WD = wide 65° beam angle 1.28 SC Finish Finish C = Specular clear H = Semi-specular clear W = White Notes Notes (3) Values are nominal, with specular clear reflector, other finishes and field results may vary. Notes Flange Integral Emergency Flange Integral Emergency Blank = Polished flange standard with C & H reflectors Blank = White flange standard with W reflector WF = White flange option available with C & H reflectors Notes IEM = Reflector for integral emergency only Notes IEM Baffle IEM Baffle 61 = 6" IEM baffle reflector for integral emergency only Distribution Distribution3 WD = wide 65° beam angle 1.28 SC (nominal) Finish Finish BB = Black baffle WB = White baffle Notes Notes (3) Values are nominal, with specular clear reflector, other finishes and field results may vary. Notes Flange Integral Emergency Flange Integral Emergency Blank = White flange standard with BB, & WB BF = Black flange option with BB Notes IEM = Reflector for integral emergency only Notes Reflector Reflector 61PS = 6" non-conductive polymer `dead front' conical reflector4 Notes (4) 61PS reflector is for Non-IC environment only, and up to 3000 lumens only. Distribution Finish Distribution3 MD = medium 60° beam angle 1.10 SC (nominal) Finish W = White Notes (3) Values are nominal, with specular clear reflector, other finishes and field results may vary. Notes Flange Flange Blank = White flange standard with W reflector Notes PS517016EN page 3 April 6, 2021 4:30 PM Product Specifications Housing Frame · Boat shaped galvanized steel plaster frame with adjustable plaster lip · Accommodates 1/2" to 1-1/2" thick ceilings · Installs in new construction or from below the finished ceiling (non-accessible) for remodeling (with mounting bars removed) · Provided with two remodel clips to secure the frame to the ceiling Universal Mounting Bracket · Adjusts 2" vertically from above and below the ceiling · Use with the included mounting bars or with 1/2" Electric Metallic Tube (EMT) · Removable to facilitate remodeling installation from below the finished ceiling Mounting Bars · Captive pre-installed No FussTM mounting bars lock to T-grid with screwdriver or pliers · Centering detents allow for consistent positioning of fixtures LED Module · Proximity phosphors over chip on board LEDs provide a uniform source with high efficiency and no pixilation · Available in 80 or 90 color rendering index (CRI) · Color accuracy within 3 SDCM provides color consistency and uniformity · 90 CRI option: R9>50 (refer to chromaticity information for details) · Available in 2700K, 3000K, 3500K and 4000K correlated color temperature (CCT) · Lumen options include 1,000, 1,500, 2,000, 3,000 and 4,000 lumens (nominal) · Passive thermal management achieves 60,000 hours at 70% lumen maintenance (L70) in insulated ceilings (IC) and non-IC applications · Integral diffuse lens provides visual shielding · Integral connector allows quick connection to housing flex Reflector · Self-flanged aluminum reflectors available in narrow, medium or wide distribution patterns · Medium distribution polymer non-conductive matte white reflector may be used to meet local codes for `dead front' applications (Non-IC, 3,000 lumens max.) · Wall wash reflector features a rotatable linear spread lens for alignment of vertical illumination · Reflectors attach to LED module with three speed clamps · Available in multiple painted or plated finishes Reflector/Module Retention · Reflector/module assembly is securely retained in the housing with two torsion springs Driver · Field-replaceable constant current driver provides low noise operation · Universal 120-277VAC 50/60Hz input standard · 347VAC 50/60Hz input option (Canada only) · Continuous, 1% to 100% dimming with 0-10V analog control · Optional low-voltage DC driver for use with Distributed Low Voltage Power (DLVP) system · Distributed Low Voltage Power (DLVP) system combines power, lighting and controls with ease of installation (refer to DLVP Design Guide at www.cooperlighting.com for details) Emergency Option · Provides 90 minutes of standby lighting, meeting most life safety codes for egress lighting · Available with integral or remote charge indicator and test switch · Available Self-Test (self-diagnostic) with remote charge indicator and test switch Connected Lighting System Options Two WaveLinx connected systems to choose. Summary information provided below, refer to WaveLinx system specifications and application guides for details. WaveLinx Wireless System Tilemount Sensor Kit · WaveLinx Wireless WTA tile mount sensor kit offers daylight dimming, PIR motion sensing, scene and zone configuration, automatic commissioning; and optional RLTS - Real Time Location Services available. WaveLinx Lite System Tilemount Sensor Kit · WaveLinx Lite WTK tile mount sensor kit offers daylight dimming and PIR motion sensing, scene and grouping configuration. WaveLinx Tilemount Kits Application · The WTA and WTK tilemount kits include a control module mounted on the luminaire junction box via 1/2" knock-out, and a tilemount sensor on 54-inch whip; for ceiling installation by direct-mount spring clips or via mounting bracket in octagon ceiling boxes. · The WTA and WTK tilemount kits may be ordered as factory installed on the luminaire, or ordered separately as a field installed accessory kit. HC6 | HM6 | 61 | 61PS Junction Box · Galvanized steel junction box · 20 in3 internal volume excluding voltage barrier · 25 in3 internal total volume · Voltage barrier for 0-10V dimming wires (occupies one 1/2" pry-out space) · Listed for eight #12 AWG (four in, four out) 90°C conductors and feed-thru branch wiring · Three 1/2" and two 3/4" trade size pry-outs available · Three 4-port push wire nuts for mains voltage with 1-port for fixture connection Compliance · cULus damp and wet location listed in protected ceilings · IP20 - Above finished ceiling; IP65 - Below finished ceiling · Non-Insulated ceiling (Non-IC) rated for 3,000 and 4,000 lumen models (insulation must be kept 3" from top and sides) · Insulated ceiling (IC) rated for 1,000, 1,500 and 2,000 lumen models and suitable for direct contact with air permeable insulation* (IC models are also suitable for Non-IC installations) · Airtight per ASTM-E283-04 · Suitable for use in clothes closets when installed in accordance with the NEC 410.16 spacing requirements · EMI/RFI emissions FCC CFR Title 47 Part 15 Class A at 120/277V · Contains no mercury or lead and RoHS compliant · Photometric testing completed in accordance of IES LM-79-08 · Lumen maintenance projection in accordance of IES LM-80-08 and TM-21-11 · 1,000, 1,500 and 2,000 lumen, 90 CRI, ICAT models may be used to comply with State of California Title 24 residential code, per JA8 certification standards · May be used to comply with State of California Title 24 non-residential code as a dimmable LED luminaire · ENERGY STAR® certified, reference certified light fixtures database *Not for use in direct contact with spray foam insulation, consult NEMA LSD57-2013 Warranty · Five year limited warranty, consult website for details. www.cooperlighting.com/legal PS517016EN page 4 April 6, 2021 4:30 PM Photometric Data HC6 | HM6 | 61 | 61PS View IES files NARROW DISTRIBUTION - SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K NARROW (55° BEAM*) Test Number P285970 Housing Module HC620D010 HM612835 Reflector 61NDC Lumens Efficacy SC UGR 1920 Lm 96 Lm/W 0.97 11.7 CANDLEPOWER DISTRIBUTION Downlight 90º 498 75º 996 60º 1495 1993 45º 15º 30º CONE OF LIGHT 0º D MH FC L W 5.5' 64.9 5.2 5.2 7' 40 6.8 6.8 8' 30.7 7.6 7.6 9' 24.2 8.6 8.6 10' 19.6 9.6 9.6 12' 13.6 11.6 11.6 CANDELA TABLE Degrees Vertical 0 5 15 25 35 45 55 65 75 85 90 Candela 1962 1962 1975 1434 671 112 13 3 3 0 0 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 1385 72.1 0-40 1796 93.5 0-60 1915 99.7 0-90 1920 100 9 0 -18 0 0 0 0 -18 0 1920 100 LUMINANCE Average Candela Degrees Average 0° Luminance 45 8706 55 1223 65 337 75 551 85 0 MEDIUM DISTRIBUTION - SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K MEDIUM (60° BEAM*) Test Number P286170 Housing HC620D010 Module HM612835 Reflector 61MDC Lumens Efficacy SC UGR 1959 Lm 97.9 Lm/W 1.10 11.8 CANDLEPOWER DISTRIBUTION Downlight 90º 475 75º 950 1425 1900 60º 45º 15º 30º CONE OF LIGHT 0º D MH FC L W 5.5' 55.2 5.8 5.8 7' 34.1 7.6 7.6 8' 26.1 8.6 8.6 9' 20.6 9.6 9.6 10' 16.7 10.8 10.8 12' 11.6 13 13 CANDELA TABLE Degrees Vertical 0 5 15 25 35 45 55 65 75 85 90 Candela 1642 1660 1854 1576 699 120 15 5 3 0 0 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 1387 70.8 0-40 1821 93 0-60 1951 99.6 0-90 1959 100 9 0 -18 0 0 0 0 -18 0 1959 100 LUMINANCE Average Candela Degrees Average 0° Luminance 45 9236 55 1462 65 662 75 551 85 0 Note: Refer to IES files for more product data. PS517016EN page 5 April 6, 2021 4:30 PM HC6 | HM6 | 61 | 61PS WNAIDRERDOIWSTDRIISBTURTIBIOUNT I-OSNP-ECSUPLEACRULCALREACRLEFAINRIFSIHN,IS2 0H0, 02 0L0U0MLEUNMMEONDMELO,D8E0L,C8R0I,C3R5I0, 03K5 0 0 K WIDE (65° BEAM*) Test Number P286370 Housing HC620D010 Module HM612835 Reflector 61WDC Lumens 2045 Lm Efficacy SC UGR 102.3 Lm/W 1.28 11.6 CANDLEPOWER DISTRIBUTION Downlight 90º 75º 412 824 60º 1235 1647 45º 15º 30º CONE OF LIGHT 0º D MH FC L W 5.5' 44.3 7 7 7' 27.4 8.8 8.8 8' 21 10.2 10.2 9' 16.6 11.4 11.4 10' 13.4 12.6 12.6 12' 9.3 15.2 15.2 CANDELA TABLE Degrees Vertical 0 5 15 25 35 45 55 65 75 85 90 Candela 1341 1349 1466 1642 877 201 28 5 2 0 0 *Value are nominal with specular clear reflectors, other finishes and field results may vary. SC = Spacing Criteria UGR = Unified Glare Rating Photometric Multipliers (Nominal Lumen Values) ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 1282 62.7 0-40 1835 89.7 0-60 2037 99.6 0-90 2045 100 9 0 -18 0 0 0 0 -18 0 2045 100 LUMINANCE Average Candela Degrees Average 0° Luminance 45 15614 55 2676 65 662 75 530 85 0 1000 Lumen 1500 Lumen 0.52 0.72 Multipliers for relative lumen values with other series models. Color Finish Multipliers Finish code C H 2000 Lumen 1.00 W/WB 3000 Lumen 1.44 4000 lumen 2.02 BB Finish Specular Clear Semi-Specular Multiplier 1.00 0.91 Multipliers for relative lumen values with other color finishes. CCT Multipliers - 80CRI Matte White White Baffle 0.92 Black Baffle 0.84 2700K 3000K 3500K 4000K 0.93 0.95 1.00 Multipliers for relative lumen values with other series color temperatures. 1.05 CCT Multipliers 90CRI 2700K 3000K 3500K 0.75 0.82 0.90 Multipliers for relative lumen values with other series color temperatures. 4000K 0.89 PS517016EN page 6 April 6, 2021 4:30 PM HC6 | HM6 | 61 | 61PS WALL WASH DISTRIBUTION - SPECULAR CLEAR FINISH, 2000 LUMEN MODEL, 80 CRI, 3500K WALL WASH Test Number P286650 Housing HC620D010 Module HM612835 Reflector 61RWWC Lumens 1798 Lm Efficacy SC 89.9 Lm/W 1.23 CANDLEPOWER DISTRIBUTION Downlight 90º 228 75º 455 60º 683 45º 910 15º 30º CANDELA TABLE Degrees Vertical 0 5 15 25 35 45 55 65 75 85 90 Candela 882 890 910 854 665 431 270 161 74 10 0 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 696 38.7 0-40 0-60 0-90 9 0 -18 0 0 -18 0 1079 1629 1798 0 1798 60 90.6 100 0 100 LUMINANCE Average Candela Degrees Average 0° Luminance 45 33399 55 25825 65 20832 75 15653 85 6416 SC = Spacing Criteria, nominal for specular clear reflector, other finishes and field results may vary. SINGLE UNIT FOOTCANDLES 2.5' from wall (distance from fixture along wall) 1 16.8 12 5.4 2 0.7 0.2 0.1 2 24.7 19.2 10.5 4.9 2.2 1 0.5 3 22.8 18.6 11.4 6.2 3.2 1.7 0.9 4 17.5 15 10.3 6.2 3.6 2 1.2 5 11.9 10.7 8.2 5.5 3.4 2.1 1.3 6 8 7.4 6.1 4.5 3.1 2 1.3 7 5.5 5.2 4.5 3.6 2.6 1.9 1.3 8 3.9 3.7 3.3 2.8 2.2 1.6 1.2 9 2.8 2.7 2.5 2.2 1.8 1.4 1.1 10 2.1 2 1.9 1.7 1.5 1.2 0.9 MULTIPLE UNIT FOOTCANDLES 2.5' from wall (Distance from fixture along w3all) 1 18.8 16.6 18.8 2 29.5 29.2 29.5 3 29 29.8 29 4 23.7 25.3 23.7 5 17.4 19.2 17.4 6 12.5 13.7 12.5 7 9.1 9.8 9.1 8 6.7 7.1 6.7 9 5 5.3 5 2.5' from wall (Distance from fixture along w4all) 17.5 10.7 17.5 26.8 20.9 26.8 26 22.9 26 21 20.5 21 15.4 16.3 15.4 11.1 12.2 11.1 8.1 9 8.1 6.1 6.7 6.1 4.6 5 4.6 10 3.8 4 3.8 3.5 3.8 3.5 Photometric Multipliers (Nominal Lumen Values) 1000 Lumen 1500 Lumen 2000 Lumen 0.52 0.72 1.00 Multipliers for relative lumen values with other series models. 3000 Lumen 1.44 4000 Lumen 2.02 Color Finish Multipliers Finish code C H W/WB Finish Specular Clear Semi-Specular Matte White White Baffle Multiplier 1.00 0.91 0.92 Multipliers for relative lumen values with other color finishes. BB Black Baffle 0.84 CCT Multipliers 80CRI 2700K 3000K 3500K 4000K 0.93 0.95 1.00 1.05 Multipliers for relative lumen values with other series color temperatures. CCT Multipliers 90CRI 2700K 3000K 3500K 4000K 0.75 0.82 0.90 0.89 Multipliers for relative lumen values with other series color temperatures. PS517016EN page 7 April 6, 2021 4:30 PM Energy & Performance Data COLOR METRICS - TM-30-15 & CRI/CIE (3500K) 80 CRI Color Metric Summary - 3500K* TM-30-15 Rf = 84.7 Rg = 95.7 CRI/CIE Ra = 85.2 R9 = 16.9 2700K 3000K 3500K 4000K HC6 | HM6 | 61 | 61PS 90 CRI Color Metric Summary - 3500K* TM-30-15 Rf = 90.1 Rg = 98.7 CRI/CIE Ra = 92.5 R9 = 66.2 2700K 3000K 3500K 4000K * Color values are based on 61WDWB reflector, other finishes and field results may vary. 55° 60° narrow medium Nominal Beam 65° wide * Color values are based on 61WDWB reflector, other finishes and field results may vary. 55° 60° narrow medium Nominal Beam 65° wide Series 1000 lumen Input Voltage 120-277VAC 120V 277V Input Current (A) 0.085 0.042 Input Power (W) 10.1 10.9 In-rush Current (A) 0.644 1.95 In-rush Duration (ms) 0.125 0.24 THDi (%) 8.6 15.6 PF : 0.90 (Nominal input 120-277VAC & 100% of rated output power) Minimum starting temperature -30°C (-22°F)* Sound Rating: Class A standards Series 3000 lumen Input Voltage 120-277VAC 120V 277V Input Current (A) 0.228 0.102 Input Power (W) 27.2 27 In-rush Current (A) 0.898 1.7 In-rush Duration (ms) 0.36 0.38 THDi (%) 9.7 9.3 PF : 0.90 (Nominal input 120-277VAC & 100% of rated output power) Minimum starting temperature -30°C (-22°F)* Sound Rating: Class A standards Series 1500 lumen Input Voltage 120-277VAC 120V 277V Input Current (A) 0.119 0.055 Input Power (W) 14.2 14.9 In-rush Current (A) 0.212 0.85 In-rush Duration (ms) 0.28 0.32 THDi (%) 7.8 16.3 PF : 0.90 (Nominal input 120-277VAC & 100% of rated output power) Minimum starting temperature -30°C (-22°F)* Sound Rating: Class A standards Series 4000 lumen Input Voltage 120-277VAC 120V 277V Input Current (A) 0.345 0.15 Input Power (W) 41.3 40.7 In-rush Current (A) 1.05 2.23 In-rush Duration (ms) 0.32 0.34 THDi (%) 10.06 14.01 PF : 0.90 (Nominal input 120-277VAC & 100% of rated output power) Minimum starting temperature -30°C (-22°F)* Sound Rating: Class A standards Notes: * Emergency Battery packs are rated for a minimum starting temperature of 0°C. Series 2000 lumen Input Voltage 120-277VAC 120V 277V Input Current (A) 0.176 0.082 Input Power (W) 21.1 21.4 In-rush Current (A) 0.588 0.624 In-rush Duration (ms) 0.3 0.38 THDi (%) 8.8 11.2 PF : 0.90 (Nominal input 120-277VAC & 100% of rated output power) Minimum starting temperature -30°C (-22°F)* Sound Rating: Class A standards PS517016EN page 8 April 6, 2021 4:30 PM Connected Systems WaveLinx Lite - WTK Tilemount Sensor HC6 | HM6 | 61 | 61PS · Intuitive AndroidTM or Apple® iOS® app for basic system code compliant set up and configuration via Bluetooth · Up to 28 unique areas per project site (WaveLinx Lite Bluetooth network) · Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes · Automatic occupancy or vacancy, sensor sensitivity, daylight dimming, etc. configurable through the app · Refer to the WaveLinx system specifications for details Device Security Manual Dimmer Occupancy Sensor Daylighting Control Manually Switched ON/OFF Tuning Control Lumen Maintenance Control Scenes 120-277 VAC WaveLinx Lite WTK Tilemount Wiring Diagram Black (Hot) White (Neutral) Control module (MSP3IVMVDC1EP) Gray (Dimming) Purple (Dimming) Blue (Not Switched) White (Neutral) 0-10V DImming Driver WaveLinx Lite Bluetooth Enabled System WaveLinx Lite Mobile Application Includes switchleg (Blue load out wire) and 0-10V to each fixture controlled 120-277 VAC 3A downlights with 0-10V control WaveLinx Lite Tilemount Sensor Kit control module (MSP3IVMVDC1EP) (included) 54" Plenum cable (5140-000123-00) (included) ceiling tile ceiling tile WaveLinx Lite Sensor and Mounting Trim (included) WaveLinx Lite Integrated Ambient WaveLinx Lite Tilemount Sensor Kit WaveLinx Lite Wallstation WaveLinx Lite Integrated Parking Garage WaveLinx Wireless WTA Tilemount Sensor · WaveLinx Wireless functionality configures zones and customizes settings from one secure mobile app · Automatic code commissioning that meets the strictest codes · Fixtures and sensors integrate with Wireless Area Controller, Wall Stations, and Control Devices · Stand-Alone Offices or Entire Building Network Installations + Downlights with tilemount sensor wireless communication Highly efficient LED fixtures ++ Wireless Area Controller Provides centralized coordination of multiple area control options Wireless Wall Station/Receptacle Provides customized wireless control of each area Mobile Applications Provides personalized, local control from a tablet or smartphone WaveLinx mobile app settings Manual Dimmer Occupancy Sensor Lumen Maintenance Control Daylighting Control Receptacle Control Tuning Control Scheduling Manually Switched ON/OFF Demand Response 120-277 VAC WaveLinx Lite WTA Tilemount Wiring Diagram Black (Hot) White (Neutral) Control module (MSP3IVMVDC1EP) Gray (Dimming) Purple (Dimming) Blue (Not Switched) White (Neutral) 0-10V DImming Driver Includes switchleg (Blue load out wire) and 0-10V to each fixture controlled 120-277 VAC 3A downlights with 0-10V control WaveLinx Lite Tilemount Sensor Kit control module (MSP3IVMVDC1EP) (included) 54" Plenum cable (5140-000123-00) (included) ceiling tile ceiling tile WaveLinx Sensor and Mounting Trim (included) WaveLinx Wireless Trellix Building Management Integration BACnet/IP Public (REST) API Desktop/Laptop with web browser (hardware provided by user) Trellix Core Third Party system (hardware provided by others) Building LAN Touchscreen BACnet Router1 (hardware provided by others) PoE Power WaveLinx Mobile App used for system setup and personal control Wireless Area Controller PS517016EN page 9 April 6, 2021 4:30 PM max module height (see table) 26.4" [670.56mm] Dimensional and Mounting Details NEW CONSTRUCTIONS - HIGH LUMEN 3000 AND 4000 LUMEN NEW CONSTRUCTION - HIGH LUMEN 3000 AND 4000 LUMEN max module height (see table) 8.6" [217.35mm] LED height (see table) 3.42" [86.77mm] (driver height) HC6 | HM6 | 61 | 61PS trim height (see table) .5" [12.70mm] (ceiling thickness) 6.06" [153.92mm] (reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm] (trim flange) NEW CONSTRUCTIONS - LOW LUMEN 1000, 1500, AND 2000 LUMEN NEW CONSTRUCTION - LOW LUMEN 1000, 1500, AND 2000 LUMENS LED height (see table) 3.42" [86.77mm] (driver height) .5" [12.70mm] (ceiling thickness) m] 6.06" [153.92mm] (reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm] (trim flange) trim height (see table) max module height (see table) 4.2" [107.34mm] hanger bar bracket LED height (see table) 3.42" [86.77mm] height (removable) (driver height) .5" [12.70mm] (ceiling thickness) 6.06" [153.92mm] (reflector inner aperture) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.85mm] (trim flange) trim height (see table) NEW CONSTRUCTION - LOW LUMEN 1000, 1500, AND 2000 LUMENS max module height (see table) hanH[1g0ei7r4.gb3.a24hr"mbrmaLc]kuet mL(sEeDeehtnaebigleh()t3[8063.07.4702m"m&] 4000 Lumens) height (removable) (driver height) Distribution Max. Module Height Narrow .5" [12.70mm] (ceiling thickness) Medium 6.6" 6.7" Wide 6.5" Trim Height 6.06" [153.92mm] (reflector inner 3ape.r4tur"e) 7.25" [184.15mm] (ceiling cut out) 7.75" [196.835m.5m"] (trim flange) 3.3" Baffle 6.5" 3.3" *Max. height w/hanger bar bracket 4.2" LED Height Low Lumen (1000, 1500 & 2000 Lumens)* trim height (see table) Max. Module Height Trim Height 3.8" 4.5" 3.4" 3.9" 4.6" 3.5" 3.7" 4.4" 3.3" 3.7" 4.4" 3.3" LED Height 3.8" 3.9" 3.7" 3.7" Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com © 2020 Cooper Lighting Solutions All Rights Reserved. Specifications and dimensions subject to change without notice. PS517016EN page 10 April 6, 2021 4:30 PMAdobe PDF Library 15.0