Instruction Manual for ACCESS SYSTEMS models including: Professional Residential Exit Wand
Obtain the instruction manual for the gate opener. 2. Locate the control terminals (2) that will ONLY OPEN the gate.
ACCESS SYSTEMS PROFESSIONAL RESIDENTIAL EXIT WAND INSTALLATION MANUAL WARNING When an EXIT WAND is in use, the automatic gate opener could be activated by a child on a bicycle or other metal play equipment. This Product is not recommended for applications exposed to children. Parts Identification: Double Spade Connectors (2) ! WWAARRNNIINNGG GATE OPENING SENSOR IN USE The Automatic Gate Opener is activated when a vehicle comes within range of the sensor buried along side the driveway and could possibly be activated by a child on a bicycle, tricycle or other metal play equipment. SENSOR with 50, 100 or 150 feet of Direct Burial Cable Warning Signs (2) ! WARNING Wire Clamp Wire Nuts (2) Battery Connection Wires (2) Ty-Wraps (4) Gates that Open, LLC · 3121 Hartsfield Road · Tallahassee, Florida 32303 1-800-543-GATE (4283) · Technical Support 1-800-543-1236 www.gtoaccess.com RWINST01PRO rev-12/28/11 INSTALLATION OVERVIEW Gate Opener Control Box Open Gate Outside Sensor Range Minimum of 25 feet PVC conduit in ground and up to control box recommended SENSOR: 2 feet from driveway edge and 1 foot in ground 12" 24" · The SENSOR is designed to detect ironbased metal in motion. · The SENSOR's ability to detect iron-based metal objects is based on the mass, velocity and proximity of the object to the sensor. EXAMPLE - A child's bicycle moving at 2 mph @ 1' from the sensor has a similar effect as a car moving at 2 mph @ 6' from the sensor. · The SENSOR must be stationary to function properly. RANGE: 12 ft. radius (max) SENSOR: 2 ft. from Driveway (max) and12 in. deep Open Gate Outside Sensor Range Driveway Gate Opener Control Box ( allow 5 ft. for wiring to Control Box) WIRING THE WAND 1. Obtain the instruction manual for the gate opener. WAND WIRING 2. Locate the control terminals (2) that Braided Ground will ONLY OPEN the gate. 3. Verify that the above inputs when shorted (a small wire connecting the 2 terminals) will do all of the following: · OPEN the gate if the gate is idle. · STOP and then OPEN the gate if gate is closing. · DO NOTHING if the gate is opening. Black RELAY OUTPUT Blue Normally open relay contacts, closes for 2 seconds when moving vehicle is detected. TO OPEN ONLY INPUT OF GATE OPENER CONTROL Red + 11-30 Vdc POWER INPUT = 8-26orVac Yellow IMPORTANT DO NOT CONNECT THE POWER INPUT WIRES TO THE POWER SOURCE (i.e. 12 V battery) UNTIL INSTRUCTED TO DO SO. 2 GTO Exit Wand Instructions 12.28.11 TURN GATE OPENER OFF 4. Connect the BLACK to the terminal labeled COMMON, and the BLUE wire to terminal in STEP 3 to open gate. Battery Cable Double Spade Connectors RED (+) included with SENSOR WIRING DIAGRAM EXAMPLES NOTE: Power Input Connections Not Shown. (See gate instruction manual for complete instructions) GRN ORG BLU WHT ON SEQ1 SEQ2 LEARN R BG ALARM ACCESSORY RCVR Connect the Black wire from the SENSOR CABLE to one of the COMMON terminals on the opener control board. Connect the BLUE wire from the SENSOR CABLE to the BLU terminal on the opener control board. BLACK BLUE SFTY. EXIT CYCLE EDGE SENSOR COMMON LOCK+ LOCK WHT GRN RED BLK WHT GRN RED BLK 14 VAC O R Battery Cable BLACK (-) YELLOW wire from SENSOR CABLE BRAIDED GROUND from SENSOR Cable RED wire from SENSOR Cable BLACK BATTERY CONNECTION WIRE with Spade Connector included with SENSOR RED BATTERY CONNECTION WIRE with Spade Connector included with SENSOR 5. Connect the POWER INPUT wires to power source. · Connect the YELLOW and BRAIDED GROUND wires to the () NEGATIVE side of power source. (i.e. battery) · Connect the RED wire to the (+) POSITIVE side of power source. (i.e. battery) IMPORTANT WHEN THE WAND IS FIRST POWERED UP IT MUST BE UNDISTURBED FOR 60 SECONDS TO PERFORM THE SELF TEST AND CALIBRATIONS. BEFORE POWERING THE WAND MAKE SURE THERE ARE NO MOVING METAL OBJECTS OR MOVING VEHICLES WITHIN THE RANGE OF THE WAND 6. Turn opener ON and TEST. LINK Connect the BLUE wire from the SENSOR CABLE to the EXIT terminal on the opener control board. EXIT SAFETY EDGE CYCLE COMMON GRN BLK RED RECR Connect the BLACK wire from the SENSOR CABLE to one of the COMMON terminals on the opener control board. BLUE BLACK VAR1 VAR2 VAR3 PWR. VAR4 VAR5 PF1 K1 K2 BATT + K3 K4 Connect the BLUE wire from the SENSOR CABLE to the EXIT terminal on the opener control board. BLUE BLACK FIRST OPR. SECOND OPR. Connect the Black wire from the SENSOR CABLE to one of the COMMON terminals on the opener control board. CONTROL INPUTS RECEIVER Connect the BLACK wire from the SENSOR CABLE to one of the COMMON terminals on the opener control board. COM COM CYCLE SAFETY EXIT SHADOW CLOSE EDGE OPEN EDGE GRN BLK RED ALM GTO RCVR. Connect the BLUE wire from the SENSOR CABLE to the EXIT terminal on the opener control board. BLUE BLACK POWER CHGR CHGR COM SAFETY EXIT CYCLE EDGE COM LOCK+ LOCK - Connect the BLUE wire from the SENSOR CABLE to the EXIT terminal on the opener control board. BLUE BLACK Connect the Black wire from the SENSOR CABLE to one of the COMMON terminals on the opener control board. GTO Inc. SX4000 L COM COM COM COM COM COM STOP CLOSE OPEN RUN 2 SAFETY SHADOW LOOP OPEN EDGE CYCLE Connect the BLUE wire from the SENSOR CABLE to the OPEN terminal on the opener control board. Connect the BLACK wire from the SENSOR CABLE to one of the COMMON terminals on the opener control board. BLACK BLUE GTO Exit Wand Instructions 12.28.11 3 TECHNICAL SPECIFICATIONS: · Power Supply: 8-26 Vac - 11-30 Vdc · Operating Temperature: 25°F (-14°C) · Current consumption 3 mA. typical to 125°F (-69°C), or battery operating temperature · Relay rating: 1 amp max, 30 Vdc · Dimensions: 1¾" (44.5 mm) diameter x 16½" · Relay Pulse Time: 2 seconds (42cm) long TROUBLESHOOTING: Make sure all connections are correct · Disconnect the power (battery) to the WAND. · Reconnect the power to the WAND and make sure that no metal object or vehicle is moving around the WAND for 60 seconds while it is calibrating. · Test the WAND to verify that it is working properly. This product and any accessory you purchase should only be installed on a gate opener that meets the current safety standard, UL325. If you have a gate opener that is not listed with the current standard please contact GTO sales department for consultation on a gate opener that can meet your specific needs. Conversion Chart Converting Metric Units to English Equivalents When You Know Multiply by To Find Centimeters Meters Kilograms 0.3937 3.2808 2.2046 Inches Feet Pounds Symbol in. ( ") ft. ( `) lb. (#) Converting English Units to Metric Equivalents When You Know Multiply by To Find Inches 2.5400 Centimeters Feet 0.3048 Meters Pounds 0.4535 Kilograms Symbol cm m kg Converting Temperature deg. Celsius (ºC x 1.8) + 32 deg. Fahrenheit ºF deg. Fahrenheit (ºF-32) ÷ 1.8 deg. Celsius ºC GTO LIMITED ONE YEAR WARRANTY Gates that Open, LLC (GTO), accessories are warranted by the manufacturer against defects in materials and manufacturer workmanship for a period of one (1) year from date of purchase, provided the recommended installation procedures have been followed. In the case of product failure due to defective material or manufacturer workmanship within the one (1) year warranty period, the product will be repaired or replaced (at the manufacturer's option) at no charge to the customer, if returned freight prepaid to GTO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303. IMPORTANT: Call (800) 543-1236 for a Return Goods Authorization (RGA) number before returning accessory to factory. Products received at the factory without an RGA number will not be accepted. Replacement or repaired parts are covered by this warranty for the remainder of the one (1) year warranty period or six (6) months, whichever is greater. GTO will pay the shipping charges (equal to United Parcel Service GROUND rate) for return to the owner of items repaired under warranty. The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or for the reinstallation of those parts after repair. This warranty shall be considered void if damage to the product(s) was due to improper installation or use, connection to an improper power source, or if damage was caused by electrical power surge or lightning, wind, fire, flood, insects or other natural agent. After the one (1) year warranty period, GTO will make any necessary repairs for a nominal fee. Call GTO at (800) 543-1236 for more information. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. This warranty is in lieu of all other warranties, expressed or implied. NOTE: Verification of the warranty period requires copies of receipts or other proof of purchase. Please retain these records. For your nearest dealer, please call 1-800-543-GATE (4283) or visit www.gtoaccess.com