User Guide for Akuvox models including: MD06 6 Call Buttons with Name Tags, MD06 6, Call Buttons with Name Tags, Buttons with Name Tags, Name Tags
Akuvox 3-fach Unterputzkasten für Akuvox MD06/MD12
MD06/MD12 Dual-unit Device Accessories Torx Triple-unit device Accessories M4x15 Torx head screw 2 MD06/MD12 Before You Start Tools needed (not included in shipped box) Cat Ethernet Cable Crosshead Screwdriver Electric Drill Voltage and Current Specifications It is suggested that use 12-24VDC 0.1A power adapter to power on device. AWG Sizes and Properties Table Please follow the properly wire data to install device: Power Supply 12-24VDC 0.1A AWG 26 Resistance (ohm/km) 128 Cross-sectional Area (mm²) 0.14 Wire Length (m) \ 3 MD06/MD12 Requirements 1.Place the device away from sunlight and light sources to prevent potential damage. 2.Do not place the device in the high-temperature, and humid environments or in surroundings impacted by magnetic field. 3.Install the device on the flat surface securely to avoid personal injuries and property loss caused by device's falling. 4.Do not use or place the device near heating objects. 5.If installing the device indoors, please keep device at least 2 meters away from light, and at least 3 meters away from window and door. Backlight Direct sunlight Direct sun through window Indirect sunlight through window Close to light Warning! 1.To ensure safety, avoid touching power core, power adapter, and device with wet hands, bending or pulling the power core, damaging any components, and use only qualified power adapter and power cord. 2.Be careful that standing up on the area under the device in case of personal injuries cause by hitting the device. Cautious 1.Do not knock device with hard objects. 2.Do not press down hard on the device screen. 3.Do not expose device to chemical products, such as alcohol, acid liquid, disinfectants, and so on. 4.To prevent the device installation from becoming loose, ensure accurate diameters and depths of screw holes. If the screw holes are too large, use glue to secure the screws. 5.Use wet cloth clean device surface softly, and then wipe the surface with dry cloth for cleaning the device. 6.If there is abnormal situation of the device, including uncommon sound and smell, please power off the device and contact Akuvox Technical Team immediately. Wiring Interface 4 MD06/MD12 C The flush-mounting box installation is done. Step2: Main Unit Installation A a. Combine R20K/B, MD06, and MD12 with the flush-mounting bracket according to the direction indicated in the drawing. b. Use twelve M3x6.8 wall-mounting screws to fasten devices. B a. For easier installation, hang the device on the box/bracket using the rope. b. Press sealing ring into the corresponding groove. C a. Insert 4-Pin cable to terminal of MD06 and MD12. b. Make cables go through the wiring cover, connecting to the corresponding interfaces as needed (for details, refer to "Wiring Interface"). c. Fasten rubber plug (M) to R20K/B device and rubber plug (S) to MD06 and MD12 device for securing cables. d. Fasten sealing pressing plate with two M2.5x6 crosshead screws. MD06/MD12 C Remove the box and use a 6mm electric drill to make holes on the marked position. D Insert four plastic wall anchors into holes. E a. Lead wires go through the cable holes. b. Press the flush-mounting box into the square hole, ensuring that the edges closely against the wall. c. Use four ST4x20 crosshead screws to fix flush-mounting box. Note: The flush-mounting box is not positioned higher than wall, which can be lower 0-3mm. The box tilt angle does exceed than 2°. F The flush-mounting box installation is done. 1.2 Simple Installation (with lower resistance of vandalism) 9 MD06/MD12 A 188mm 209mm Cut out a square hole on the wall with the dimension 209*188*40mm (height*width*depth). Note: Make sure that the cables within the hole or reserve a cable tube. 1431mm a. Fill the gap between the wall and the flush-mounting box with cement or B non-corrosive adhesive. b. Brush the outer surface of the gap with the same decorative materials as the surrounding walls. c. Wait for the cement to dry before proceeding to the next step. Note: To prevent water from entering the back cover of the door phone, it is recommended to fill the gaps around with waterproof material. C The flush-mounting box installation is done. Step2: Main Unit Installation A a. Combine R20K/R20B and MD06/MD12 with the flush-mounting bracket according to the direction indicated in the drawing. b. Use eight M3x6.8 wall-mounting screws to fasten devices. B a. For easier installation, hang the device on the box/bracket using the rope. b. Press sealing ring into the corresponding groove. 10