Rockwell Automation Publication 700-TD552F-EN-P - January 2021 ... Options: LED, push-to-test and manual override, socket-mounted surge ...
4 Rockwell Automation Publication 700-TD552F-EN-P - January 2021. Relay and Timer Specifications. Contact Data Tables.
Technical Data Original Instructions Relay and Timer Specifications Bulletin 700 Topic Page Topic Page Summary of Changes 2 Solid-state Relays 233 General Information 3 700-SA Tube Base Relays 237 General Purpose Relays 9 700-SC Ice Cube Relays 240 700-HA General-purpose Relay 12 700-SF Square Base Relays 245 700-HB Square Base Relay 22 700-SH Hockey Puck Relays 249 700-HD Flange Mount Square Base Relay 28 700-SK Slim Line Relays 258 700-HF Square Base Relay 32 700-HC Miniature Ice Cube Relay 39 700-HK Slim Line Relay 44 700-HL Terminal Block Relay 50 700-HL 2-pole Terminal Block Relay 56 700-HLF Terminal Block Timing Relay 60 700-HP Slim Line Relay 64 700-HPS Safety Control Relay 65 700-HJ Magnetic Latching Relay 71 700-HG Power Relay 75 700-HHF Flange Mount Power Relay 80 700-HTA Alternating Relay 83 General Purpose Electronic Timers and Counters 89 700-FE Economy Timing Relay 92 700-FS High Performance Timing Relay 96 700-HNC Miniature Timing Relay 103 700-HNK Ultra-Slim Timing Relay 109 700-HR Dial Timing Relays 116 700-HT Plug-in Timing Relay 128 700-HV Timing Relay 133 700-HX Multi-Function Digital Timing Relay 138 NEMA Industrial Relays 149 700-P Industrial Relays 151 700S-P and 700S-PK -- Heavy-Duty Safety Control Relays 167 700-N Industrial Relays 172 700-R Sealed Switch Relays 176 700-RTC -- Solid-State Timing Relay 181 IEC Control Relays 187 700-CF Control Relay 188 700S-CF Control Relays 208 700-EF Control Relay 213 700S-EF Control Relays 221 700-K Miniature Control Relays 225 Relay and Timer Specifications Technical Data Summary of Changes This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes. Topic Page Added 700-EF Control Relay 213 Added 700S-EF Control Relays 221 2 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications General Information Contact Data Tables Relay Contact Contact Type Arrangement Style Contact Material NEMA Pilot Duty(1) AC and DC Switching Capability 1 mA 20 50 mA mA 100 mA 1A 3A 5 A 10 A 20 A 25 A 30 A 35 A 700-CF Up to 8 form X or 8 form Y cross stamped Ag A600 P600 24V 700S-CF Up to 8 form X or 8 form Y cross stamped Ag A600 24 P600 V AC DC AC DC IEC Relays 700-K Up to 8 form X or 8 form Y bifurcated AgCu A300 Q300 17V AC DC 700-P Up to 12 form X or 8 form Y bifurcated NiAg A600 P600 700-PK Up to 12 form X or 8 form Y single AgCdO 2X A600 2X P600 NEMA Relays 700-PH Up to 6 form X or 4 form Y tandem AgCdO A600 P600 700-R Up to 8 form A or form B sealed sw. W B300 C600 5V P300 700-RTC Up to 4 form A or form B sealed sw. W 700S-P Up to 12 form X or 8 form Y bifurcated NiAg (1) See NEMA Ratings and Test Values on page 5 B600 P300 5V A600 P600 10V 10V 10V 10V AC DC DC AC (20 A Lighting Load) AC DC (35 A Lighting Load) AC DC AC DC AC Rockwell Automation Publication 700-TD552F-EN-P - January 2021 3 Relay and Timer Specifications Contact Data Tables Relay Contact Contact Type Arrangement Style Contact Material NEMA Pilot Duty 1 mA 10 50 mA mA AC and DC Switching Capability 100 mA 1A 3A 5 A 10 A 20 A 25 A 30 A 35 A Timing Relays General Purpose Relays 700-FE 1 N.O. single AgCdO D300 10V 700-FS 1, 2 form C single AgCdO B300 10V 700-HA 2, 3 form C single AgNi B300 10V 700-HAX 2, 3 form C bifurcated Au/AgNi B300 6V 700-HB 2, 3 form C single AgNi B300 10V 700-HC14 4 form C 700-HC22 2 form C 700-HC24 4 form C single Ag/Au C300 Q300 10V single AgNi B300 Q300 10V single AgNi C300 Q300 10V 700-HD 2, 3 form C single AgCdO B300 10V 700-HF 2, 3, 4 form C single 700-HG 700HHF45 1 form X, 1 form C, 2 form A, 2 single form C 1 form X single 700HHF62 2 form C single 700HHF73 3 form C single AgCdO B300 AgNi A600 AgNi A600 AgNi B600 AgNi B300 700-HJ 1, 2 form C single AgCdO -- 700-HK36 1 form C 700- 1 form C 700-HK32 2 form C 700- 2 form C single AgNi B300 single Au/AgNi B300 single AgNi B300 single Au/AgNi B300 10V 10V 10V 10V 10V 10V 10V 5V AC DC (24V Max.) AC DC (24V Max.) AC DC (24V Max) AC DC (24V Max) AC DC (24VMax.) AC DC (30V Max.) AC DC AC DC (30V Max.) AC DC (24V Max) AC DC (30V Max) AC DC (28V Max) AC DC (28V Max) AC DC (28V Max) AC DC (28V Max) AC DC (24V Max.) AC DC (30V Max) AC DC (30V Max) 4 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Contact Data Tables Relay Type Contact Arrangement Contact Style Contact Material NEMA Pilot Duty AC and DC Switching Capability 1 mA 10 50 mA mA 100 mA 1A 3A 5 A 10 A 20 A 25 A 30 A 35 A General Purpose Relays (continued) 700-HLS 700-HLT 700-HLT_ _X 700-HP 700-HPX Solid-State 1 N.O. -- 1 Form C single 1 Form C single 2 Form C single 2 Form C single -- -- AgSnO B300 R300 AgSnO B300 R300 AgNi B300 Q300 AgNi + B300 Gold Q300 3V 12V 8V 5V (300 mW) 5V (50 mW) 700-HS 2 Form C single AgCdO B300 10V AC/ DC 6 A AC/DC 6 A AC/DC 8 A AC/DC 8 A AC/DC AC (30V DC Max) 700-HT 2 form C single AgNi B300 10V AC (30V DC Max) NEMA Ratings and Test Values NEMA Ratings and Test Values for AC Control Circuit Contacts at 50 or 60 Hz Maximum Current [A] NEMA Contact Rating Thermal Continuous 120V Designation Test Current [A] Make A150 10 60 A300 10 60 A600 10 60 B150 5 30 B300 5 30 B600 5 30 C150 2.5 15 C300 2.5 15 C600 2.5 15 D150 1.0 3.60 D300 1.0 3.60 D600 0.5 1.80 2X A300 20 120 2X A600 20 120 Break 6.00 6.00 6.00 3.00 3.00 3.00 1.50 1.50 1.50 0.60 0.60 0.30 12 12 240V Make Break -- -- 30 3.00 30 3.00 -- -- 15 1.50 15 1.50 -- -- 7.5 0.75 7.5 0.75 -- -- 1.8 0.30 -- -- 60 6.00 60 6.00 480V Make Break -- -- -- -- 15 1.50 -- -- -- -- 7.5 0.75 -- -- -- -- 3.75 0.375 -- -- -- -- -- -- -- -- 30 3.00 600V Make Break -- -- -- -- 12 1.20 -- -- -- -- 6 0.60 -- -- -- -- 3 0.30 -- -- -- -- -- -- -- -- 24 2.40 VA Make Break 7200 720 7200 720 7200 720 3600 360 3600 360 3600 360 1800 180 1800 180 1800 180 432 72 432 72 216 36 14400 1440 14400 1440 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 5 Relay and Timer Specifications NEMA Ratings and Test Values for DC Control Circuit Contacts Maximum Current [A] NEMA Contact Rating Designation Thermal Continuous Test Current [A] 5...28V 125V 250V 301...600V N150 10 N300 10 N600 10 P150 5.0 P300 5.0 P600 5.0 Q300 2.5 Q600 2.5 2X P600 10 10 2.2 -- -- 10 2.2 1.1 -- 10 2.2 1.1 0.40 5.0 1.1 -- -- 5.0 1.1 0.55 -- 5.0 1.1 0.55 0.20 2.5 0.55 0.27 0.11 2.5 0.55 0.27 0.11 10 2.2 1.1 0.40 Make or Break at 300V or less [VA] 275 275 275 138 138 138 69 69 275 NEMA Definitions for Contact Arrangements Contact Description Arrangement Form A A Form A contact arrangement is one that has single-pole, single-throw, normally open contacts. The function of this arrangement is to close a circuit when actuated. Diagram Form B A Form B contact arrangement is one that has single-pole, single-throw, normally closed contacts. The function of this arrangement is to open a circuit when actuated. Form C A Form C contact arrangement is one that has single-pole, double-throw contacts with three terminals - one for normally open, one for normally closed, and one common. The function of this arrangement is to transfer a circuit when actuated. Form X A Form X contact arrangement is one that has single-pole, single-throw, normally open double-make contacts. The function of this arrangement is to close a circuit when actuated. or Form Y A Form Y contact arrangement is one that has single-pole single-throw normally closed double-break contacts. The function of this arrangement is to open a circuit when actuated. or Form Z A Form Z contact arrangement is one that has single-pole, double-throw, contacts with four terminals -- two for normally open and two for normally closed. The function of this arrangement is to open one circuit and close the other. 6 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Timing Relay Selection Criteria Single Function Timers: Timers that have only 1 timing mode (for example, ON-Delay or OFF-Delay). Multi-Function Timers: Timers that have 4...8 timing modes that are selected by turning the mode selection switch. RESET ON-Delay or (Delay on Operate) When power is applied continuously (or when power and a start signal are applied), the timing cycle begins. The output contacts change state after the time delay is completed. The contacts will return to their normal state when a reset signal is applied or power is removed. POWER ON OFF START SIGNAL ON OFF OUTPUT CHANGED STATE NORMAL STATE TIME DELAY RESET OFF-Delay or (Delay on Release) Power is applied continuously. When a start signal is applied, the output contacts change state immediately. When the start signal is removed, the timing cycle begins. The output contacts will return to their normal state once the time delay is completed. Reset will occur when a reset signal is applied or power is removed. POWER ON OFF START SIGNAL ON OFF OUTPUT CHANGED STATE NORMAL STATE TIME DELAY RESET One Shot or (Repeat Cycle) Power is applied continuously. When a start signal is applied, the output contacts change state immediately and the timing cycle begins. The output contacts will return to their normal state once the time delay is completed. Reset will occur when a reset signal is applied or power is removed. POWER ON OFF START SIGNAL ON OFF OUTPUT CHANGED STATE NORMAL STATE TIME DELAY Repeat Cycle or (Flicker) Power is applied continuously. When a start signal is applied, the timing cycle begins. When the time delay is completed, the output contacts change state and the next timing cycle begins. This cycle will repeat until a reset signal is applied or power is removed. POWER ON OFF START SIGNAL ON OFF OUTPUT CHANGED STATE NORMAL STATE RESET OFF ON OFF ON OFF TIME TIME TIME TIME TIME Flexibility Mounting -- Timing relays are available in several different models. They can be plugged into the same socket as the relay, or use a separate plug-in socket mounting. Contacts -- The contacts are of various types and ratings. See the appropriate specification pages for more details. Functionality -- Timing relays with multi-range and multi-function capability are available. Allowing you to stock one relay to cover a wide variety of applications. External Trigger Switch -- OFF-Delay, One-Shot, and other timer functions require an external trigger switch (from a relay or push button) to control the timing function. The external trigger switch will cause the timing function to start. In OFF-Delay, the trigger switch closes to energize the output and when the trigger switch opens the OFF-Delay starts to time out. At the end of the time delay, the output is de-energized and the output contacts return to their shelf state Rockwell Automation Publication 700-TD552F-EN-P - January 2021 7 Relay and Timer Specifications Surge Suppression Information Photo 700-CF Relay Cat. No. For use with Suppression Technique 700-ADR 700-ADL1 700-ADL1R 700-ADL2 700-ADL2R 700-ADL3 700-ADL3R 700-AR1 700-AR2 700-AV1R 700-AV3R 700-CF built-in 100-FSC 100-FSV 100-FSD 700-HA, -HB,-HK, -HP (6...220V DC) 700-HC (6...24V DC) 700-HB, -HA, -HK, -HP (6...24V DC) 700-HC (28...60V DC) 700-HB, -HA, -HK, -HP (28...60V DC) 700-HC (110...220V DC) 700-HB, -HA, -HK, -HP (110...220V DC) 700-HB, -HA, -HC,-HK, -HP (6...24V AC/DC) 700-HB,-HA, -HC,-HK, -HP (110...240V AC/DC) 700-HB,-HA, -HC,-HK, -HP (6...24V AC) 700-HB, -HA, -HC, -HK, -HP (110...240V AC) -- 100C, 700-CF 100C, 700-CF Diode Diode + LED Diode + LED Diode + LED Diode + LED Diode + LED Diode + LED RC RC Varistor + LED Varistor + LED Diode R-C Ckt MOV 100C, 700-CF Diode Max. Relay Contact Dropout Time 3X 3X 3X 3X 3X 3X 3X No Effect No Effect No Effect No Effect -- No Effect No Effect Max. Transient Voltage Relative to System Voltage -- -- -- -- -- -- -- 3 -- -- -- 6...10X 3X -- 70...95 ms 6...10X 100-JE 100C, 700-CF Diode 5X 6...10X 700-R Relay 8 700-N5 700-P, 700-N RC No effect 3X 700-N24 700-P, 700-N RC 700-R built-in -- Diode 199-FSMA1, FSMA2 700-P, 700-H, 700-CF, 700DC-R RC 199-FSMA9, 10, 11 700-P, 700-H, 700-CF, 700DC-R MOV 199-FSMZ 700-P, 700-H, 700-CF, 700DC-R Diode No effect 3X -- No effect No effect 6...10X 3X -- 5X -- Rockwell Automation Publication 700-TD552F-EN-P - January 2021 General Purpose Relays Product Overview Relay and Timer Specifications Bulletin No. Type Features Contact Ratings Contact Form Contact Type Contact Material Operating Current, Under Resistant Load, Max Permissible Load, min Coil Ratings Coil Voltage Permissible Coil Voltage Variation Electrical Ratings Dielectric Withstand Voltage Electrical Service Life (Cycles) Reference Certifications Socket Catalog Numbers Page 700-HA General-purpose Relay · Pin-style terminals · Standard ON/OFF flag indicator · Electrical schematic on face · Clear cover for visual inspection · Optional push-to-test and manual override · Optional LED 700-HB 700-HD 700-HF General-purpose Relay General-purpose Relay General-purpose Relay · Blade-style quick connect terminals · Standard ON/OFF flag indicator · Electrical schematic on face · Clear cover for visual inspection · Optional push-to-test and manual override · Optional LED · Flange-mounted · Blade-style quick connect terminals · Clear cover for visual inspection · Square-base · Plug-in quick connect solder terminals · Optional push-to-test · Optional LED DPDT, 3PDT Single AgNi, AgNi + Gold 700-HA: 10 A 700-HAX: 6 A 700-HA: 10V, 5 mA 700-HAX: 6V 1 mA DPDT, 3PDT Single AgCdO 15 A 10V, 10 mA DPDT, 3PDT Single AgCdO 15 A 10V, 10 mA DPDT, 4 PDT Single AgCdO 10 A 5V, 100 mA AC: 6, 12, 24, 48, 110, 120, 230, 240, 277V DC: 6, 12, 24, 36, 48, 60, 80, 110, 125, 140, 220V AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V 80...110% of nom voltage at 50 Hz 80...110% of nom voltage at 60 Hz 80...110% of nom voltage at DC AC: 6, 12, 24, 120, 208, 240V DC: 6, 12, 24, 48, 110V AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V 85...110% of nom voltage at 50 Hz 85...110% of nom voltage at 60 Hz 80...110% of nom voltage at DC Pole-to-pole: 2000V Contact-to-coil: 2000V Contact-to-frame: 2000V 100,000 min Pole-to-pole: 2500V Contact-to-coil: 4000V Contact-to-frame: 2500V 100,000 min Pole-to-pole: 2500V Contact-to-coil: 4000V Contact-to-frame: 2500V 100,000 min Pole-to-pole: 1500V Contact-to-coil: 1500V Contact-to-frame: 1500V 200,000 min 500,000 min (DPDT) CE, cULus, cURus, CSA, Lloyds CE, cULus, cURus, CSA, Lloyds 700-HN100, 700-HN101, 700-HN125, 700-HN126, 700-HN204, 700-HN205 700-HN153, 700-HN154 12 22 CE, UR, CSA, Lloyds -- 28 CE, UR, CSA 700-HN262, 700-HN264 32 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 9 Relay and Timer Specifications Bulletin Number 700-HC 700-HK 700-HL 700-HP Type Interposing/Isolation Relay Interposing/Isolation Relay Interposing/Isolation Relay Interposing/Isolation Relay Features · Blade-style terminals · Standard ON/OFF flag indicator · Electrical schematic on face · Clear cover for visual inspection · Optional push-to-test and manual override · Optional LED · Optional pilot light · Retainer clip (comes with socket) · Low switching capacity · Push-to-test and manual override · Ideal for PLC Interfaces · Built-in Coil Surge Protection · Fully Assembled Relay/Sockets · Standard LED · Relay or Solid-state Output · Optional: Leakage Current · Suppression Solution · PCB "Pin Style" mounting · 5 mm pin spacing Contact Ratings Contact Form DPDT, 4PDT SPDT, DPDT SPDT 1 N.O. (SSR) DPDT Contact Type Single Single Single Single Contact Material AgNi, AgNi + Gold AgNi, AgNi + Gold AgSnO AgNi, AgNi + Gold Operating Current, 10 A (DPDT) Under Resistant Load, Max 7 A (4PDT) 8 A (DPDT), 16 A (SPDT) 6 A (SPDT), 2 A (SSR DC output), 2 A (SSR AC output) 8 A Permissible Load, 10V, 10 mA (Gold),5V, 10 mA or min 25V, 2 mA (Silver) 5V 60 mA (Silver), 5V 10 mA (Gold) 12V 6 mA (72 mW) Silver 8V, 2.5 mA (20 mW)Gold 5V 5 mA (50 mW) Gold, 5V 5 mA (300 mW) Silver Coil Ratings Coil Voltage AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V AC: 6, 12, 24, 120, 240V DC: 6, 12, 24, 48, 110V AC: 12, 24, 48, 110, 120, 230, 240V AC: 6, 12, 24, 120, 240V DC: 12, 24, 48, 125, 230, 240V DC: 6, 12, 24, 48, 110V Permissible Coil Voltage Variation 80...110% of nom voltage at 50 Hz 80...110% of nom voltage at 50 Hz 85...110% of nom voltage at 50 Hz 80...110% of nom voltage at 50 Hz 80...110% of nom voltage at 60 Hz 80...110% of nom voltage at 60 Hz 85...110% of nom voltage at 60 Hz 80...110% of nom voltage at 60 Hz 80...110% of nom voltage at DC 73...110% of nom voltage at DC 80...110% of nom voltage at DC 73...150% of nom voltage at DC Electrical Ratings Pole-to-pole: 1000V Dielectric Withstand Voltage Contact-to-coil: 2000V Contact-to-frame: 2000V Pole-to-pole: 1500V Contact-to-coil: 1500V Contact-to-frame: 1500V Pole-to-pole: 1000V Contact-to-coil: 4000V Contact-to-frame: 1500V Pole-to-pole: 2000V Contact-to-coil: 5000V Electrical Service Life (Cycles) 100,000 min 100,000 min 100,000 min 100,000 min Reference Certifications CE, cULus, cURus, CSA, Lloyds CE, UL, UR, CSA CE, cURus, cULus, ABS CE, cULus, cURus, CSA, Lloyds Socket Catalog Numbers 700-HN103, 700-HN128, 700-HN104 700-HN121, 700-HN221, 700-HN122, 700-HN222, 700-HN223, 700-HN224 -- 700-HN123, 700-HN230 Page Number 39 44 50 64 10 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Bulletin Number 700-HJ Type Magnetic Latching Relay Features · Socket mounted · Ideal for lighting applications Contact Ratings Contact Form SPDT,DPDT(Singleor Dual Coil) Contact Type Single Contact Material AgCdO Operating Current, Under Resistant 10 A Load, Max Permissible Load, min 10V 50 mA Coil Ratings Coil Voltage AC: 24V, 120V, 240V DC: 12V, 24V Permissible Coil Voltage Variation 85...110% of nom voltage at 50 Hz 85...110% of nom voltage at 60 Hz 80...110% of nom voltage at DC Electrical Ratings Dielectric Pole-to-pole: 1500V AC Contact-to-coil: 1500V Withstand Voltage AC Contact-to-frame: 1500V AC Electrical Service Life (Cycles) 100,000 minimum Reference Certifications CE, UR, CSA Socket Catalog Numbers 700-HN153, 700-HN154 Page Number 71 700-HG Power Relay · Panel mount with screw terminals · Optional magnetic blowouts for switching DC loads · Optional snap action switch SPST-N.O.-DM, SPDT, DPST-N.O., DPDT Single AgNi 40 A 10V 50 mA AC: 24V, 120V, 240V, 277V, 480V DC: 12V, 24V, 48V, 110V, 220V, 250V 85...110% of nom voltage at 50 Hz 85...110% of nom voltage at 60 Hz 80...110% of nom voltage at DC Pole-to-pole: 2200V AC Contact-to-coil: 2200V AC Contact-to-frame: 2200V AC 100,000 minimum CE, UL, CSA -- 75 700-HHF Power Relay · Flange mounted · Optional LED SPST-NO-DM, DPDT, 3PDT Single AgNi 20 A (3PDT), 25 A (DPDT), 30 A (SPDT) 10V 50 mA 10V 100 mA (3PDT) AC: 24V, 120V, 240V DC: 6V,12V,24V 85...110% of nom voltage at 50 Hz 85...110% of nom voltage at 60 Hz 80...110% of nom voltage at DC Pole-to-pole: 2200V AC Contact-to-coil: 2200V AC Contact-to-frame: 2200V AC 100,000 minimum CE, UR, CSA -- 80 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 11 Relay and Timer Specifications 700-HA General-purpose Relay · 10 A contact rating · DPDT, 3PDT · Pin-style terminals · Standard ON/OFF flag indicator · Options: LED, push-to-test and manual override, socket-mounted surge suppressor module, or multi-function timer · Contact choices: standard silver nickel, or bifurcated silver nickel with gold plating Tube Base Relay with PIN Terminals (Single Contact) -- Mechanical ON/OFF Indicator Included(1) Description Contact Rating Wiring Diagrams U.S./Canada International Coil Voltage Cat. No.(1) 6V AC 700-HA32A06 12V AC 700-HA32A12 24V AC 700-HA32A24 120V AC 700-HA32A1 240V AC 700-HA32A2 DPDT 2-pole 2 Form C Single AgNi Contact 10 A B300 277V AC 6V DC 12V DC 24V DC 36V DC 700-HA32A27 700-HA32Z06 700-HA32Z12 700-HA32Z24 700-HA32Z36 48V DC 700-HA32Z48 60V DC 700-HA32Z60 80V DC 700-HA32Z80 110V DC 700-HA32Z1 125V DC 700-HA32Z01 Sockets 700-HN125 700-HN100 700-HN204 140V DC 220V DC 700-HA32Z3 700-HA32Z2 6V AC 700-HA33A06 12V AC 700-HA33A12 24V AC 700-HA33A24 120V AC 700-HA33A1 3PDT 3-pole 3 Form C Single AgNi Contact 10 A B300 240V AC 6V DC 12V DC 24V DC 48V DC 700-HA33A2 700-HA33Z06 700-HA33Z12 700-HA33Z24 700-HA33Z48 60V DC 700-HA33Z60 80V DC 700-HA33Z80 110V DC 700-HA33Z1 125V DC 700-HA33Z01 Sockets 700-HN126 700-HN101 700-HN205 140V DC 220V DC 700-HA33Z3 700-HA33Z2 (1) LED Option: Add suffix (-4) to the selected 700-HA Relay Cat. No., except for the 240V AC Units, add (-4L). Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HA Relay Cat. No., except for the 240V AC units, add (-3-4L). Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HA relay. LED not available for 220V DC and 277V AC coils. (1) For Time Modules and Surge Suppressor Modules, see Accessories. 12 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Tube Base Relay with PIN Terminals (Bifurcated Contacts with Gold Overlay) -- Mechanical ON/OFF Indicator Included Description Contact Rating Wiring Diagrams U.S./Canada International DPDT 2-Pole 2 Form C Bifurcated AgNi Contacts with Gold Plating 6 A Sockets 700-HN125 700-HN100 700-HN204 3PDT 3-Pole 3 Form C Bifurcated AgNi Contacts with Gold Plating 6 A Sockets 700-HN126 700-HN101 700-HN205 Coil Voltage 6V AC 12V AC 24V AC 120V AC 240V AC 277V AC 6V DC 12V DC 24V DC 36V DC 48V DC 110V DC 125V DC 140V DC 6V AC 12V AC 24V AC 120V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC 125V DC 140V DC Cat. No 700-HAX2A06 700-HAX2A12 700-HAX2A24 700-HAX2A1 700-HAX2A2 700-HAX2A27 700-HAX2Z06 700-HAX2Z12 700-HAX2Z24 700-HAX2Z36 700-HAX2Z48 700-HAX2Z1 700-HAX2Z01 700-HAX2Z3 700-HAX3A06 700-HAX3A12 700-HAX3A24 700-HAX3A1 700-HAX3A2 700-HAX3Z06 700-HAX3Z12 700-HAX3Z24 700-HAX3Z48 700-HAX3Z1 700-HAX3Z01 700-HAX3Z3 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 13 Relay and Timer Specifications Accessories - 700-HA Relays Photo Description Pkg. Qty. Cat. No. Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Timing Relays, -HT (On-Delay), and -HRM, -HRC 10 and -HV (Repeat Cycle) Timing Relays. 700-HN100 Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC, and -HV (Repeat Cycle) Timing Relays. No 10 retainer clip required. 700-HN125 Photo 14 Screw Terminal Tube Base Sockets -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 11-pin for use with 3PDT 700-HA relays. 10 700-HN101 Screw Terminal Tube Base Sockets -- Panel or DIN Rail Mounting; Open Style Terminal Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required. 10 700-HN126 8-Pin Socket -- Can Be Used With or Without Timing Attachment or Surge Suppressor Screw Terminal Tube Base Sockets -- panel or DIN Rail mounting. Guarded terminal construction. Used with 10 DPDT 700-HA Relays. 11-Pin Socket -- Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal Tube Base Sockets -- panel or DIN Rail mounting. Guarded terminal construction. 10 Used with 3PDT 700-HA relays. 700-HN204 700-HN205 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 Description Pkg. Qty. Cat. No. Diode Surge Suppressor Voltage Range: 6...220V DC used with 700-HN204 and 700-HN205 socket 10 700-ADR Diode with LED Surge Suppressor Voltage Range: 6...24V DC used with 700-HN204 and 700-HN205 socket 10 700-ADL1R Diode with LED Surge Suppressor Voltage Range: 28...60V DC used with 700-HN204 and 700-HN205 socket 10 700-ADL2R Diode with LED Surge Suppressor Voltage Range: 110...220V DC used with 700-HN204 and 700-HN205 socket 10 700-ADL3R Varistor with LED Surge Suppressor Voltage Range: 6...24V AC used with 700-HN204 and 700-HN205 socket 10 700-AV1R Varistor with LED Surge Suppressor Voltage Range: 110...240V AC used with 700-HN204 and 700-HN205 socket 10 700-AV3R RC Surge Suppressor Voltage Range: 6...24V AC/DC used with 700-HN204 and 700-HN205 socket 10 700-AR1 RC Surge Suppressor Voltage Range: 110...240V AC/DC used with 700-HN204 and 700-HN205 socket 10 700-AR2 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Photo Description Timing Module On-Delay or One-Shot selectable voltage range: 12...24V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 110...125V AC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 230...240V AC used with sockets that accept plug-in accessory modules. On-Delay U (A1/A2) LED & R t One-Shot U (A1/A2) t LED & R 1. 1 s 0.05...1 s 2. 10 s 0.5...10 s 3. 100 s 5...100 s 4. 10 min 0.5...10 min 5. 100 min 5...100 min 6. 10 hours 0.5...10 h 7. 100 hours 8. LED Indicator Socket and Retainer Clip Reference Relay Type 700-HA32 700-HAX2 700-HA33 700-HAX3 Socket 700-HN100 700-HN125 700-HN204 700-HN101 700-HN126 700-HN205 5...100 h Retainer Clip 700-HN157 Not Required 700-HN157 700-HN157 Not Required 700-HN157 Relay and Timer Specifications Pkg. Qty. Cat. No. 1 700-AT3 1 700-AT3A1 1 700-AT3A2 1 700-HT3 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 15 Relay and Timer Specifications Specifications - 700-HA Relays Attribute Pilot Duty Rating (1) Rated Thermal Current (Ith) Rated Insulation Voltage (Ui) Inductive Contacts 120V AC 240V AC General-purpose Resistive Min. Low Energy Permissible Load Permissible Coil Voltage Variation AC Coils Coil Consumption ±10% Inrush Sealed DC Coils Must Dropout Voltage Max. Contact Resistance Design Specification/Test Requirements Pole-to-Pole Contact to Coil Electrical Life (Operating) Degree of Protection (Open Type) IEC 529 Mechanical Lifecycles (AC/DC) Switching Frequency Operations Coil Voltages Operating Time Pickup Dropout Maximum Operating Rate Vibration Endurance Operational Shock Endurance Operational Temperature Altitude Operating Storage Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Standards (1) See NEMA Ratings and Test Values on page 5. 700-HA Electrical Ratings NEMA B300 HA = 10 A 120V, 240V; HAX = 6 A 120V, 240V 250V IEC 300V UL/CSA Make Break Hp 30 A 3 A 1/3 15 A 1.5 A 1 10 A, 240V AC 10 A, 30V DC HA = 10V, 5 mA HAX = 5V, 2 mA Pickup: 80...110% of nom voltage at 50 Hz, 80...110% of nom voltage at 60 Hz, 80...110% of nom voltage at DC 50 Hz 60 Hz 3.3VA 2.85VA 2.2VA 1.9VA 1.3 W 20% of nom V AC; 10% of nom V DC 50 M (700-HA), 30 M (700-HAX) Electrical 2000V 2000V 100,000 min. Mechanical IP 40 > 20 x 106/ 50 x 106 3600/HR See Product Selection 12 ms 12 ms 4 Ops/s 5 G 2.5 G 50 G 9 G Environmental AC/DC 40...+70 °C (40...+158 °F) AC/DC 40...+100 °C (40...+212 °F) 2000 m (6560 ft) Construction Molded High-Dielectric Material Transparent Dust Cover 700-HA: 10 A AgNi 700-HAX: 6 A Bifurcated/Gold Plating AgNi In accordance with EN50 0005 8-Pin Socket -- 700-HN100, -HN125, -HN204, 11-Pin Socket -- 700-HN101, -HN126, -HN205 cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted (File No. E3125, Guide NLDX/NLDX7), CE Marked, CSA Certified, UR Certified (File 229473) UL508, CSA C22.2 No. 14, EN 61810-1 16 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay Performance Graphs Relay and Timer Specifications Cycles Max. Switching Current (A) k Reduction Factor Load (kVA) Contact life vs. AC1 load at 1,800 cycles/h Specifications - 700-HT3 Time Module Attribute Operating Voltage Range Power Consumption Degree of Protection of Input (B1) Terminal Input Terminal Wire Range Input Terminal Torque Range Status Indicator Repeat Accuracy (1) Recovery Time Selectable Timing Ranges Selectable Timing Modes Adjustable Trimmer Scale Accuracy Environmental Temperature Operating Storage Altitude Enclosure Mounting with Socket Only Sockets Certifications Standards (1) At constant voltage and temperature. Voltage DC (V) Breaking capacity for DC1 load at 1,800 cycles/h A = load applied to one contact B = load applied to two contacts in series C = load applied to three contacts in series COS Load reduction factor vs. cos 700-HT3 Electrical Ratings 12...240V AC (50/60 Hz) 12...240V DC 0.1 W (12V) 1.0 W(230V) Mechanical IP 20 (Guarded Terminal) 1.0 x 0.2 mm2...2.5 mm2 (24 ...14 AWG) 2.0 x 0.2 mm2...1.5 mm2 (24...16 AWG) 0.45...0.8 N·m (4...7 lb·in) Red ±1% <50 ms Three DIP switches, seven ranges (set from 5...100% of range): 1 s, 10 s, 100 s, 10 min, 100 min, 10 h, 100 h Three DIP switches, eight modes: 1. PowerOnDelay 2. Power On One-Shot 3. Power On Repeat Cycle, On Start 4. Signal On-Delay and Signal Off-Delay 5. Signal Off-Delay 6. Signal On-One-Shot 7. Signal Off-One-Shot 8. Signal On and Signal Off Watchdog Monitor ±5% of Time Range 20...+50 °C (4 ...+122 °F) 55...+85 °C (67...+185 °F) 2000 m (6560 ft) Construction Gray Plastic Housing 8- or 11-Pin Socket with Module Plug 700-HN204 (8-Pin with Plug), 700-HN205 (11-Pin with Plug) cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CE Marked UL508, CSA C22.2 No. 14, EN 61810-1 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 17 Relay and Timer Specifications Timing Charts - 700-HT3 Multi-function Time Module (t = Time Range 0.05 s...100 h) Terms: U is Power Input R is Relay Output S Signal, +A1 Socket, B1 Timer t is the resulting Time Delay (Red light-emitting diode) 1. Power On-delay Apply power (U) to timer. Relay contacts (R) change state after time delay (t) is complete. Contacts return to their shelf state when power is removed. Terminal B1 is not used in this mode. 3. Power On Repeat Cycle, On Start Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay (t) begins. When the time delay is complete, the contacts return to their shelf state for time delay (t) (time on = time-off). This cycle repeats until the power is removed. Terminal B1 is not used in this mode. 2. Power On One-shot Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay begins. When the time delay (t) is complete, contacts return to their shelf state. Contacts return to their shelf state when power is removed. Terminal B1 is not used in this mode. 4. Signal On-delay and Signal Off-delay Apply power (U) to timer. When the signal (S) is closed the time delay (t) begins, after the time delay is completed the relay contacts (R) change state. Opening the signal starts the time delay, after the time delay is completed the contacts return to their shelf state. If the signal is closed or opened before the time delay is complete, the time delay is reset. Contacts return to their shelf state when power is removed. Timing Charts -Cat. No. 700-HT3 Timing Modes, Time Description, Timing Charts, and DIP Switch Selections Terms: U is Power Input R is Relay Output S Signal, +A1 Socket, B1 Timer t is the resulting Time Delay (Red light-emitting diode) 5. Signal Off-delay Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state immediately. When the signal is opened, the time delay (t) begins. If the signal is closed before the time delay is complete, the time delay is reset and the relay remains energized. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed. 7. Signal Off One-shot Apply power (U) to timer. When the signal (S) is closed and then opened, the relay contacts (R) change state immediately and the time delay (t) begins. After the time delay begins, opening or closing the signal will not reset the time delay. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed. 6. Signal On One-shot Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state immediately and the time delay (t) begins. After the time delay begins, opening or closing the signal will not reset the time delay. When the time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state when power is removed. 8. Signal On and Signal Off Watchdog Monitor Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) energize immediately and the time delay (t) begins. If the signal is opened before the time delay is complete, the relay remains energized and the time delay is reset. When the time delay is completed, the contacts return to their shelf state. If the signal is opened after the time delay is complete, the relay contacts energize immediately and the same time delay begins. Continuous cycling of the signal at a rate that is faster than the time delay causes the relay contacts to remain energized. Contacts return to their shelf state when power is removed. 18 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions -700-HA Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 54.1 (2-1/8) 5.2 (13/64) 36.5 (1-9/20) 50 (1-63/64) 700-HA Relay 32.8 (1-3/10) 6.2 12.5 (15/64) (1/2) 1000 (39-3/8) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes 1.0 (0.04) 35.0 (1.38) 7.5 (0.3) 27.0 (1.06) Cat. No. A B C D 199-DR1 35 (1-3/8) 27 (1-1/16) 7.5 (19/64) 1.02 (1/64) 199-DR4 35 (1-3/8) 27 (1-1/16) 15 (19/32) 2.3 (3/32) Approx. Shipping Wt. 1.85 kg (4.07 lb) (10/pkg) 3.68 kg (8 lb) (5/pkg) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 19 Relay and Timer Specifications Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 30.0 (1-3/16) 65.0 (2-35/64) 26 (1-1/32) 38.0 (1-1/2) #440 M3 Cat. No. 700-HN100 Panel Mounting Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (#2-14 AWG... #2-20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) 40.1 (1-37/64) 24.6 (31/32) 20.8 (53/64) 24.9 (63/64) 4.2 (5/32) 54.9 (2-5/32) 51.1 (2-1/64) 33.0 (1-19/64) Cat. No. 700-HN125 14.7 (37/64) Wire Size: 2 x 2.5 mm2 Single Wire Up to 12 AWG Double Wire 2 x 2.5 mm2 (#214 AWG...#220 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) 65.0 (2-35/64) 30 (1-3/16) 38.0 (1-1/2) 26 (1-1/32) #4-40 M3 Cat. No. 700-HN101 Panel Mounting Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (#214 AWG...#220 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Cat. No. 700-HN126 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (#214 AWG...#220 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) 20 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 77.5 (3.05) 3.2 (0.13) 33.5 (1.32) 26.9 (1.06) 11.0 (0.43) 49.7 (1.96) 20.4 (0.80) 35.5 (1.40) 77.5 (3.05) 3.2 (0.13) 33.5 (1.32) 26.9 (1.06) 11.0 (0.43) 49.7 (1.96) 20.4 (0.80) 35.5 (1.40) 38.0 (1.50) 16.8 (0.66) 21.6 (0.85) 4.0 (0.16) Cat. No. 700-HN204 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (14 AWG... 20 AWG) Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) 38.0 (1.50) 16.8 (0.66) 21.6 (0.85) 4.0 (0.16) Cat. No. 700-HN205 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (14 AWG ...20 AWG) Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) 38.0 (1.50) 54 (2.13) Cat. No. 700-HT3 6.3 (0.25) 10.5 (0.41) Wire Size: 2 x 1.5 mm2 (#2 16 AWG...#120 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 21 Relay and Timer Specifications 700-HB Square Base Relay · 15 A contact rating · DPDT, 3PDT · Blade-style quick connect /solder terminals (Faston 187 - 4.8 x 0.5 mm) · Standard ON/OFF flag indicator · Options: LED, push-to-rest, and manual override Photo Description Contact Rating Wiring Diagrams U.S./Canada International DPDT 2-Pole 2 Form C 15 A Single AgCdO Contact B300 Sockets 32 34 31 Input 700-HN154 700-HN153 3PDT 3-Pole 3 Form C 15 A Single AgCdO Contact B300 Input Sockets 700-HN154 700-HN153 (1) LED Option: Add suffix (-4) to the selected 700-HB Relay Cat. No., except for the 240V AC Units, add (-4L). Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HB Relay Cat. No., except for the 240V AC units, add (-3-4L) Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HB relay. Coil Voltage 6V AC 12V AC 24V AC 120V AC 240V AC 6V DC 12V DC 24V DC Cat. No.(1) 700-HB32A06 700-HB32A12 700-HB32A24 700-HB32A1 700-HB32A2 700-HB32Z06 700-HB32Z12 700-HB32Z24 48V DC 700-HB32Z48 110V DC 6V AC 12V AC 24V AC 120V AC 240V AC 6V DC 12V DC 24V DC 700-HB32Z1 700-HB33A06 700-HB33A12 700-HB33A24 700-HB33A1 700-HB33A2 700-HB33Z06 700-HB33Z12 700-HB33Z24 48V DC 700-HB33Z48 110V DC 700-HB33Z1 22 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Accessories - 700-HB Relays Photo Description Pkg. Qty. Cat. No. Diode Surge Suppressor Voltage Range: 6...220V DC used with 700-HN204 and 700-HN205 socket 10 700-ADR Diode with LED Surge Suppressor Voltage Range: 6...24V DC used with 700-HN204 and 700-HN205 socket 10 700-ADL1R Diode with LED Surge Suppressor Voltage Range: 28...60V DC used with 700-HN204 and 700-HN205 socket 10 700-ADL2R Diode with LED Surge Suppressor Voltage Range: 110...220V DC used with 700-HN204 and 700-HN205 socket 10 700-ADL3R Varistor with LED Surge Suppressor Voltage Range: 6...24V AC used with 700-HN204 and 700-HN205 socket 10 700-AV1R Varistor with LED Surge Suppressor Voltage Range: 110...240V AC used with 700-HN204 and 700-HN205 socket 10 700-AV3R RC Surge Suppressor Voltage Range: 6...24V AC/DC used with 700-HN204 and 700-HN205 socket 10 700-AR1 RC Surge Suppressor Voltage Range: 110...240V AC/DC used with 700-HN204 and 700-HN205 socket 10 700-AR2 Timing Module On-Delay or One-Shot selectable voltage range: 12...24V AC/DC used with sockets that accept plug-in accessory modules. On-Delay U (A1/A2) LED & R t 1 700-AT3 Timing Module On-Delay or One-Shot selectable voltage range: 110...125V AC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 230...240V AC used with sockets that accept plug-in accessory modules. One-Shot U (A1/A2) t LED & R 1 700-AT3A1 1 700-AT3A2 1. 1 s 0.05 s...1 s 2. 10 s 0.5 s...10 s 3. 100 s 4. 10 min 5. 100 min 5 s...100 s 0.5 min...10 min 5 min...100 min 1 700-HT3 6. 10 hours 0.5 h...10 h 7. 100 hours 8. LED Indicator 5 h...100 h Rockwell Automation Publication 700-TD552F-EN-P - January 2021 23 Relay and Timer Specifications Photo Description Pkg. Qty. Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting. Guarded Terminal Construction 11-blade socket for use with 700-HB relays. This socket has coil and contact separation as well as the 10 ability to use optional plug-in modules (700-A__ accessories, LED, surge suppression, timing modules). 700-HN153 Screw Terminal Base Socket -- Panel or DIN Rail Mounting. Open Style Construction 11-blade for use with 700-HB relays. 10 700-HN154 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 Retainer Clip For Cat. Nos. 700-HN154 Sockets with 700-HB Relays 10 Secures relay in socket. Order must be for 10 clips or multiples of 10. Retainer Clip For Cat. Nos. 700-HN153 Sockets with 700-HB Relays 10 Secures relay in socket. Order must be for 10 clips or multiples of 10. Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot 100 on top of product covers. Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are 10 peel-off with sticky backing for easy placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10 relays. Socket and Retainer Clip Reference Relay Type 700-HB Socket Cat. No. 700-HN153 700-HN154 Retainer Clip Cat. No. 700-HN158 700-HN156 199-DR1 700-HN156 700-HN158 1492-MS5X12 1492-MS6X9 1492-MS6X12 1492-MS8X9 1492-MS8X12 1492-MP-Blank 700-N40 700-N41 24 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Specifications - 700-HB Relays Attribute Pilot Duty Rating (1) RatedThermal Current (Ith) Rated Insulation Voltage (Ui) Inductive Contacts 120V AC 240V AC General-purpose Resistive Min. Low Energy Permissible Load Permissible Coil Voltage Variation Coil Consumption ±10% AC Coils Inrush Sealed DC Coils Max. Allowable Leakage Max. Contact Resistance Dielectric Withstand Voltage Pole-to-Pole Contact to Coil Degree of Protection (Open Type) IEC 529 Mechanical lifecycles (AC/DC) Switching Frequency Operations Coil Voltages Pickup Operating Time (ms) Dropout Maximum Operating Rate Vibration Endurance Operational Endurance Shock Operational Temperature Altitude Operating Storage Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Standards (1) See NEMA Ratings and Test Values on page 5. Relay and Timer Specifications 700-HB Electrical Ratings NEMA B300 15 A 120V, 240V 250V IEC-300V UL/CSA Make Break Hp 2 -Pole 3 -Pole 2 -Pole 3 -Pole 60 A 30 A 6 A 3 A 3/4 30 A 15 A 3 A 1.5 A 2 15 A, 240V AC 15 A, 30V DC 1000 mW (10V, 10 mA) 80...110% of Nominal Voltage at 50 Hz 80...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC 50 Hz 60 Hz 3.3VA 2.85VA 2.2VA 1.9VA 1.3 W 25% of VA 10% of W 50 M Design Specification/Test Requirements 2500V 4000V Mechanical IP 40 > 10 x 106/30 x 106 3600/HR See Overview/Product Selection 20 ms 4 ms 4 Ops/s 5 G 1.5 G 50 G 15 G Environmental AC/DC 40...+70 °C (40...+158 °F) AC/DC 40...+100 °C (40...+212 °F) 2000 m (6560 ft) Construction Molded High Dielectric Material Transparent Dust Cover AgCdO In accordance with EN50 0005 700-HN153, -HN154 cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted UL508, CSA C22.2 No. 14, EN 61810-1 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 25 Cycles Relay and Timer Specifications Technical Data - 700-HB Relays Load (kVA) Contact life versus AC1 load at 600 cycles/h. Maximum Switching Current (A) Voltage DC (V) Breaking capacity for DC1 load at 600 cycles/h. Load applied to one contact. A = for N.O. types B= other types Reduction Factor (Highly Resistive) COS Load Reduction factor versus cos (Inductive) 26 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700-HB Relays Approximate Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 60.9 (2.40) 30.25 35.8 38.2 (1.19) (1.41) (1.50) 40 27.0 (1.57) (1.06) 51.4 (2.02) 700-HB Relay Ø 3.2 (0.13) 34.3 (1.35) 46.3 (1.82) 91.3 (3.59) 95.3 (3.75) 35.4 (1.39) 21.6 (0.85) 35.5 (1.40) 32.0 (1.26) Cat. No. 700-HN153 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (14 AWG... 20 AWG), Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) 49.5 (1.95) 35.4 (1.40) 25.6 (1.01) 84.85 (3.34) 84.3 (3.32) 41.5 (1.63) 4.0 (0.16) Cat. No. 700-HN154 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (14 AWG... 20 AWG), Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) 38.0 (1.50) 54 (2.13) 6.3 (0.25) 10.5 (0.41) Cat. No. 700-HT3 Wire Size: 2 x 1.5 mm2 (#2 16 AWG...#120 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 27 Relay and Timer Specifications 700-HD Flange Mount Square Base Relay · Flange-mounted/panel-mounted · 15 A contact rating · DPDT, 3PDT · Blade-style quick connect terminals (0.187 x 0.020) · Solder terminals (no socket required) Photo Contact Rating Wiring Diagrams U.S./Canada DPDT 2-Pole 2 Form C 15 A AgCdO Contacts Input 3PDT 3-Pole 3 Form C 15 A AgCdO Contacts Input International 32 34 31 Coil Voltage Cat. No. 6V AC 12V AC 24V AC 120V AC 208V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC 6V AC 12V AC 24V AC 120V AC 208V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC 700-HD32A06 700-HD32A12 700-HD32A24 700-HD32A1 700-HD32A20 700-HD32A2 700-HD32Z06 700-HD32Z12 700-HD32Z24 700-HD32Z48 700-HD32Z1 700-HD33A06 700-HD33A12 700-HD33A24 700-HD33A1 700-HD33A20 700-HD33A2 700-HD33Z06 700-HD33Z12 700-HD33Z24 700-HD33Z48 700-HD33Z1 Accessories - 700-HD Relays Photo Description Pkg. Qty. Cat. No. Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot on top of 100 product covers. Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10 easy placement on relays. 1492-MS5X12 1492-MS6X9 1492-MS6X12 1492-MS8X9 1492-MS8X12 1492-MP-Blank 700-N40 Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N41 28 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-HD Relays Attribute 700-HD Pilot Duty Rating (1) Rated Thermal Current (Ith) NEMA B300 15 A(2) 120V 15 A (2) 240V, Electrical Ratings Rated Insulation Voltage(Ui) Inductive 250V IEC-300V UL/CSA Make Break Hp 2-Pole 3-Pole 2-Pole 3-Pole Contacts 120V AC 240V AC 60 A 30 A 6 A 3 A 3/4 30 A 15 A 3 A 1.5 A 2 General-purpose 15 A, 240V AC Resistive 15 A, 30V DC Min. Low Energy Permissible Load 1000 mW (10V, 10 mA) Permissible Coil Voltage Variation 80...110% of Nominal Voltage at 50 Hz 80...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC AC Coils 50 Hz 60 Hz Coil Consumption Inrush 3.3VA ±10% Sealed 2.2VA 2.85VA 1.9VA DC Coils 1.3 W Maximum Contact Resistance 50 M Must Dropout Voltage 20% of Nominal V AC 10% of Nominal V DC Design Specification/Test Requirements Electrical Dielectric Withstand Pole-to-Pole 2500V Voltage Contact to Coil 4000V Mechanical Degree of Protection (Open Type) IEC 529 IP 40 Mechanical lifecycles (AC/DC) See Overview/Product Selection Switching Frequency Operations Coil Voltages 3600/HR > 10 x 106 / 30 x 106 Pickup 20 ms Operating Time Dropout 4 ms Maximum Operating Rate 4 Ops/s Minimum Low Energy Permissible Load 1000 mN (10V, 10 mA) Environmental Temperature Operating Storage 40...+70 °C (40...+158 °F) 40...+100 °C (40...+212 °F ) Altitude 2000 m (6560 ft) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 29 Relay and Timer Specifications Attribute 700-HD Construction Insulating Material Molded High Dielectric Material Enclosure Transparent Dust Cover Contact Material Silver Cad. Ox. Terminal Markings In accordance with EN50 0005 Certifications cURs Recognized (File No. E3125, Guide NLDX2/NLDX8), CSA Certified (File No. 229473), CE Marked, UR Certified Standards UL 508, CSA C22.2 No. 14, EN 61810-1 (1) See NEMA Ratings and Test Values on page 5. (2) 3-pole relays have a 20 A maximum total current rating for all three poles. Maximum Switching Current (A) Cycles Reduction Factor Load (kVA) Contact life versus AC1 load at 600 cycles/h. Voltage DC (V) Breaking capacity for DC1 load at 600 cycles/h. Load applied to one contact. A = for N.O. types B = other types (Highly Resistive) COS (Inductive) Load Reduction factor versus cos 30 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700-HD Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 35.9 (1.41) 68 (2.67) 63 (2.48) 700-HD Relay 38.2 (1.50) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 31 Relay and Timer Specifications 700-HF Square Base Relay · 12 A contact rating · DPDT, 4PDT · Plug-in quick connect/solder terminals · Options: LED, push-to-test manual override operator · Blade size: 4.8 x 0.5 mm (0.19 x 0.02 in.) Photo Description Contact Rating Wiring Diagrams U.S./Canada International DPDT 2-pole 2 Form C AgCdO Contacts 12 A Socket 700-HN116 700-HN262 700-HN116 700-HN262 4PDT 4-pole 4 Form C AgCdO Contact 12 A Socket 700-HN139 700-HN264 700-HN139 700-HN264 (1) Pilot Light Option: Add suffix (-4) to the selected 700-HF Relay Cat. No. except for the 240V AC units, add (-4L). Manual Operator and LED Option: Add suffix (-3-4) to the selected 700-HF Relay Cat. No., except for the 240V AC units, add (-3-4L). Coil Voltage 6V AC 12V AC 24V AC 120V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC 6V AC 12V AC 24V AC 120V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC Cat. No.(1) 700-HF32A06 700-HF32A12 700-HF32A24 700-HF32A1 700-HF32A2 700-HF32Z06 700-HF32Z12 700-HF32Z24 700-HF32Z48 700-HF32Z1 700-HF34A06 700-HF34A12 700-HF34A24 700-HF34A1 700-HF34A2 700-HF34Z06 700-HF34Z12 700-HF34Z24 700-HF34Z48 700-HF34Z1 32 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Accessories - 700-HF Relays Photo Description Pkg. Qty. Cat. No. Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky 10 backing for easy placement on relays. 700-N40 Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N41 Screw Terminal Socket -- Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF relays. 10 700-HN116 Screw Terminal Socket -- Panel or DIN Rail Mounting, Guarded Terminal Construction 8-blade socket for use with DPDT 700-HF relays. The socket has the ability to use optional plug-in modules (Cat. 10 No. 700-A_ _ accessories, LED, surge suppression, timing modules). 700-HN262 Screw Terminal Socket -- Panel or DIN Rail Mounting, Guarded Terminal Construction 14-blade socket for use with 4PDT 700-HF relays. 10 700-HN139 Screw Terminal Socket -- Panel or DIN Rail Mounting, Guarded Terminal Construction 14-blade socket for use with 4PDT 700-HF relays. The socket has coil and contact separation and the ability to use 10 optional plug-in modules (Cat. No. 700-A_ _ accessories, LED, surge suppression, timing modules). 700-HN264 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HC Relays and Cat. Nos. 700-HN116, 700-HN262 Sockets with 700-HF DPDT Relays§ 10 Secures relay in socket. Order must be for 10 clips or multiples of 10. Retainer Clip for Cat. Nos. 700-HN139 and -HN264 Sockets with 700-HF 4PDT Relays§ Secures relay in socket. Order must be for 10 clips or multiples of 10. 10 700-HN114 700-HN266 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 33 Relay and Timer Specifications Accessories - 700-HF Relays Photo Description Diode with LED Surge Suppressor Voltage Range: 6...24V DC used with sockets that accept plug-in accessory modules. Diode with LED Surge Suppressor Voltage Range: 28...60V DC used with sockets that accept plug-in accessory modules. Diode with LED Surge Suppressor Voltage Range: 110...220V DC used with sockets that accept plug-in accessory modules. Varistor with LED Surge Suppressor Voltage Range: 6...24V AC used with sockets that accept plug-in accessory modules. Varistor with LED Surge Suppressor Voltage Range: 110...240V AC used with sockets that accept plug-in accessory modules. RC Surge Suppressor Voltage Range: 6...24V AC/DC used with sockets that accept plug-in accessory modules. RC Surge Suppressor Voltage Range: 110...240V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 12...24V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 110...125V AC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 230...240V AC used with sockets that accept plug-in accessory modules. Socket, and Retainer Clip Reference Relay Type 700-HF32 700-HF34 Cat. No. Socket 700-HN116 700-HN262 700-HN139 700-HN264 Cat. No. Retainer Clip 700-HN114 700-HN266 Pkg. Qty. Cat. No. 10 700-ADL1 10 700-ADL2 10 700-ADL3 10 700-AV1R 10 700-AV3R 10 700-AR1 10 700-AR2 700-AT3 700-AT3A1 1 700-AT3A2 34 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications- 700-HF Relays Electrical Ratings Contacts Inductive V AC 230V AC 120V AC VDC DC-1 Resistive Operating Range Rated Power Holding Voltage Must Drop Out Voltage Insulation Voltage AC DC AC DC AC (50 Hz) DC AC DC AC DC Dielectric Withstand Voltage Mechanical Degree of Protection Mechanical Life Operations Switching Frequency Operations Coil Voltages Operating Time at nom voltage at 20 °C Maximum Operating Rate Vibration Shock Pole-to-Pole Contact to Pole Pickup Dropout Temperature Altitude Operating Storage Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Standards 700-HF 2 Pole AC 15 @ 700 VA AC-1 @ 3000 VA 1 Hp @ 240V AC 1/2 Hp @ 120V AC 12 A @ 30V DC 0.5 A @ 110V DC 0.25 A @ 220V DC 12 A @ 250 V AC (per pole) 12 A @ 30 V DC (per pole) 80...110% nom voltage 80...110% nom voltage 1.5 VA 1 W 80% nom voltage 60% nom voltage 20% nom voltage 10% nom voltage 250V AC Design Specification/Test Requirements 2500V AC 2500V AC 700-HF 4 Pole 85...110% nom voltage 2 VA 1.3 W Open Type (Sockets) 20 x 106 3600/hr See Product Selection 8 ms 10 ms 3 ms 4 ms 4 Ops/s 15 G 15 G Environmental 40...+70 °C (40...+268 °F) 50...+80 °C (89...+176 °F) 2000 m (6560 ft) Construction Molded High-Dielectric Material Transparent Dust Cover Silver Cad. Oxide In accordance with EN50 0005 8-Blade Socket (DPDT) Cat. No. 700-HN116 & 700-HN262, 14-Blade Socket (4PDT) Cat. No. 700-HN139 & 700-HN264 CSA Certified (File No. 229473), UL Recognized (File No. E3125, Guide NLDX2/NLDX8), CE Marked, UL Listed when used with sockets shown above, (File No. E3125, Guide NLDX/NLDX 7), LR Certified, RINA Certified, IMQ Certified UL 508, CSA 22.2 No. 14, EN-61810-1 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 35 Relay and Timer Specifications Dimensions -700-HF Relays Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes. 700-HF Relay (DPDT) 700-HF (4PDT) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes Cat. No. 199-DR1 199-DR4 A B C D Approx. Shipping Wt. 35 27 7.5 1.02 1.85 kg (1-3/8) (1-1/16) (19/64) (1/64) (4.07 lb) (10/pkg) 35 27 15 2.3 3.68 kg (1-3/8) (1-1/16) (19/32) (3/32) (8 lb) (5/pkg) 36 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700-HF Relays Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes. Cat. No. 700-HN116 Wire Size: 2 x 2.5 mm Single Wire Up to #12 AWG Double Wire 2.5 mm (14 ... 20 AWG), Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Cat. No. 700-HN262 Wire Size: Solid - 1x6/ 2 x 2.5 mm 1x10 / 2 x 14 AWG Stranded - 1x4 / 2x2.5 mm 1x12 / 2x14 AWG Length: 9 mm (3/8 in.) - Torque: 0.8 N·m (7 lb· in) 300V AC, 12 A, 50 °C Rockwell Automation Publication 700-TD552F-EN-P - January 2021 37 Relay and Timer Specifications Cat. No. 700-HN139 Wire Size: 2 x 2.5 mm Single Wire Up to #12 AWG Double Wire 2.5 mm (14 ... 20 AWG), Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Cat. No. 700-HN264 Wire Size: Solid - 1x6/ 2 x 2.5 mm 1x10 / 2x14 AWG Stranded - 1x4 / 2x2.5 mm 1x12 / 2x14 AWG Length: 9 mm (3/8 in.) - Torque: 0.8 N·m (7 lb·in) 300V AC, 10 A, 70 °C 38 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-HC Miniature Ice Cube Relay · 7 or 10 A contact ratings · 2PDT or 4PDT · Standard ON/OFF flag indicator · Blade-style terminals (2.0 x 0.5 mm) · Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts for low-energy applications · Options: LED, push-to-test with manual override option · Tungsten UL Approvals · 4-Pole: 5A @ 24V DC · 2-Pole: 10A @ 24V DC Photo Contact Rating Wiring Diagrams U.S./Canada International 2PDT 10 A 2-Pole C300 2 Form C R300 Contacts: Low energy rating; 10 A = AgNi (10V, 10 mA) Contacts 100 mW Input Coil Voltage Cat. No.(1) 12V DC 24V DC 24V AC 700-HC22Z12 700-HC22Z24 700-HC22A24 120V AC 700-HC22A1 700-HN128 700-HN103 700-HN104 4PDT 4-Pole 4 Form C Contacts: 7A = AgNiAu Gold Plated Contacts 7 A Low energy rating; (5V, 10 mA or 25V, 2 mA) 50 mW Input 4PDT 4-Pole 4 Form C Contacts: 7A = AgNi Silver Contacts 7 A C300 R300 Low energy rating; (10V, 10 mA) 100 mW 700-HN128 700-HN103 700-HN104 (1) LED Option: Add suffix (-4) to the selected 700-HC Relay catalog number, except for the 240V AC units, add (-4L). Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HC catalog number, except for the 240V AC units, add (-3-4L). Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HC relay catalog number. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 240V AC 6V AC 12V AC 24V AC 120V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC 6V AC 12V AC 24V AC 120V AC 240V AC 6V DC 12V DC 24V DC 48V DC 110V DC 700-HC22A2 700-HC14A06 700-HC14A12 700-HC14A24 700-HC14A1 700-HC14A2 700-HC14Z06 700-HC14Z12 700-HC14Z24 700-HC14Z48 700-HC14Z1 700-HC24A06 700-HC24A12 700-HC24A24 700-HC24A1 700-HC24A2 700-HC24Z06 700-HC24Z12 700-HC24Z24 700-HC24Z48 700-HC24Z1 39 Relay and Timer Specifications Accessories - 700-HC Relays Photo Description Diode with LED Surge Suppressor Voltage Range: 6...24V DC used with 700-HN104 socket Diode with LED Surge Suppressor Voltage Range: 28...60V DC used with 700-HN104 socket Diode with LED Surge Suppressor Voltage Range: 110...220V DC used with 700-HN104 socket Varistor with LED Surge Suppressor Voltage Range: 6...24V AC used with 700-HN104 socket Varistor with LED Surge Suppressor Voltage Range: 110...240V AC used with 700-HN104 socket RC Surge Suppressor Voltage Range: 6...24V AC/DC used with 700-HN104 socket RC Surge Suppressor Voltage Range: 110...240V AC/DC used with 700-HN104 socket Timing Module On-Delay or One-Shot selectable voltage range: 12...24V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 110...125V AC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 230...240V AC used with sockets that accept plug-in accessory modules. Pkg. Qty. Cat. No. 10 700-ADL1 10 700-ADL2 10 700-ADL3 10 700-AV1R 10 700-AV3R 10 700-AR1 10 700-AR2 700-AT3 1 700-AT3A1 700-AT3A2 Screw Terminal Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction.Ith = 10 A per pole. 14-blade miniature socket for use with 700-SC Relays. 10 700-HN103 Screw Terminal Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction Ith = 10 A per pole. 14-blade miniature socket for use with 700-HC relays. This socket has coil and contact separation as well as the ability to plug in 10 optional plug in modules (700-A__ accessories: LED, Surge Suppression, Timing Modules) 700-HN104 Screw Terminal Base Socket -- Panel or DIN Rail Mounting; Open-Style Construction Ith = 10 A per pole. 14-blade miniature socket for use with 700-HC Relays. 10 700-HN128 40 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Photo Description Pkg. Qty. Cat. No. DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HC Relays. Secures relay in socket.(1) Plastic Retainer and Ejection Lever For use with the 700-HN104 Sockets for 700-HC relays. Built-in ability to accept 1492 Snap-in Markers (1) See 700-HC Miniature Square Base Relay, Socket, and Retainer Clip Reference Chart. 10 700-HN114 10 700-HN124 Photo Description Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. Squares slip into molded slot on top of product cover. Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. Pkg. Qty. Cat. No. 5 1492-MS5X12 5 1492-MS6X9 5 1492-MS6X12 5 1492-MS8X9 5 1492-MS8X12 100 1492-MP-Blank 10 700-N40 Markers -- Used for terminal identification 50 700-N41 Socket and Retainer Clip Reference Relay Type 700-HC Socket Cat. No. 700-HN103 700-HN128 700-HN104 Retainer Clip Cat. No. 700-HN114 700-HN114 700-HN114 or 700-HN124 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 41 Relay and Timer Specifications Specifications- 700-HC Relays Attribute Pilot Duty Rating (1) Rated Thermal Current (Ith) Rated Insulation Voltage (Ui) Inductive 700-HC Electrical Ratings NEMA C300, R300 7 A and 10 A 250V IEC 300V UL/CSA 700-HC_4 Hp 700-HC22 Hp Make Break Make Break Contacts 120V AC 240V AC 15 A 1.5 A 1/8 7.5 A 0.75 A 1/3 15 A 1.5 A 1/3 7.5 A 0.75 A 3/4 General-purpose 7 A, 277V AC 10 A, 277V AC Resistive 7 A, 30V DC 10 A, 24V DC Min. Low Energy Permissible Load 100 mW (10V, 10 mA) - Silver Contacts 50 mW (5V, 10 mA, or 25V, 2 mA) - Gold Contacts Permissible Coil Voltage Variation Pickup: 80...110% of nom voltage at 50 Hz 80...110% of nom voltage at 60 Hz 80...110% of nom voltage at DC Must Dropout Voltage: 20% of nom voltage at AC 10% of nom voltage at DC Coil Consumption ±10% AC Coils DC Coils Max. Allowable Leakage Inrush Sealed Dielectric Withstand Voltage Electrical Life (Cycles) Pole-to-Pole Contact to Coil Degree of Protection (Open Type) IEC 529 Mechanical lifecycles Switching Frequency Operations Coil Voltages Operating Time Pickup Dropout Maximum Operating Rate Temperature Altitude Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Operating Storage 50 Hz 60 Hz 2.2VA 1.6VA 1.3VA 1.1VA 1.0 W 20% of VA (AC) 10% of W (DC) Design Specification/Test Requirements Electrical 2000V 2000V 100,000 min Mechanical IP 20 (Guarded Terminal Sockets) 20 x 106 (AC), 50 x 106 (DC) 1800/HR See Product Selection 10 ms 3 ms 8 cycles/s Environmental 30...+55 °C (22...+131 °F) 55...+85 °C (67...+185 °F) 2000 m (6560 ft) Molded High Dielectric Material Transparent Dust Cover AgNi(700-HC2), AgNi + 5 m All (700-HC1) In accordance with EN50 0005 700-HN103, -HN128, -HN104 cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), cULus Listed when used with 700- HN103, -HN104, and -HN128 sockets (File No. E14843, Guide NRNT/NRNT7), CE Marked, LR Certified Standards UL 508, CSA 22.2 No. 14, EN 61810-1 (1) See General Information on page 3. 42 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions, 700-HC Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 36.7 (1.44) 37.2 (1.46) 20.7 (0.82) 6.1 (0.24) 27.7 (1.09) 700-HC Relay (Two-Pole) 27.0 (1.06) 20.7 (0.82) 27.7 (1.09) 700-HC Relay (Four-Pole) 5.6 (0.22) 60.9 (2.40) 21.5 (0.85) 76.0 (2.99) 34.9 (1.37) 3.2 (0.13) 2.5 (0.10) 35.6 (1.40) 32.0 (1.26) 35.5 (1.40) 18.9 (0.74) Cat. No. 700-HN104 Single Wire: 0.2 mm2...2.5 mm2 (24 AWG...14 AWG), Double Wire: 0.2 ...2.5 mm2 (24 AWG...14 AWG), Qty. 2 wires Wire Type: solid or stranded, copper only, Strip Length: 7 mm (9/32 in.), Torque: 0.5 N·m (4.4 lb·in) Panel Mounting 24.5 (31/32) 28.9 (1-9/64) 30.0 (1-3/16) 6.1 (15/64) 8765 4321 24.9 (57/64) 21.1 (53/64) 67.0 (2-5/8) 30.0 (1-11/64) #4-40 M3 Cat. No. 700-HN103 Single Wire: 0.2 mm2...2.5 mm2 (#24 AWG...14 AWG) Double Wire: 0.2...2 x 1.5 mm2 (24 AWG...16 AWG), Qty. 2 wires Wire Type: Solid or Stranded, Copper only Strip Length: 8 mm (5/16 in.), Torque: 0.5 N·m (4.4 lb·in) 4.2 (5/32) 62.0 (2-15/64) 14 13 12 11 10 9 65.0 (2-9/16) 26.0 (1-1/64) Cat. No. 700-HN128 Wire Size: 2 x 1.5 mm2 (#2-16 AWG...#1-20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Toque: 0.8 N·m (7 lb·in) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 43 Relay and Timer Specifications 700-HK Slim Line Relay · 8 A/16 A contact ratings · DPDT/SPDT · Plug-in blade-style terminals (2.5 x 0.5 mm) · Retainer clip with sockets · Options: LED, push-to-test and manual override, socket-mounted surge suppressor module, or timer module · Standard ON/OFF flag indicator · Relay faceplate accepts optional Bulletin1492 snap-in markers · Choice of standard silver/nickel contacts or silver/nickel with gold plated contacts · Maximum duty version available Photo Description Contact Rating Wiring Diagrams U.S./Canada International Coil Voltage Cat. No.(1) 6V AC 700-HK36A06 12V AC 700-HK36A12 24V AC 700-HK36A24 SPDT 1-Pole 1 Form C AgNi Contacts 16 A 120V AC 240V AC 6V DC 700-HK36A1 700-HK36A2 700-HK36Z06 12V DC 700-HK36Z12 Input 24V DC 700-HK36Z24 48V DC 700-HK36Z48 Socket 700-HN121, 700-HN221, 700-HN223 700-HN121, 700-HN221, 700-HN223 110V DC 700-HK36Z1 6V AC 700-HK32A06 12V AC 700-HK32A12 24V AC 700-HK32A24 DPDT 2-Pole 2 Form C AgNi Contacts 8 A 120V AC 240V AC 6V DC 700-HK32A1 700-HK32A2 700-HK32Z06 12V DC 700-HK32Z12 Input 24V DC 700-HK32Z24 48V DC 700-HK32Z48 Socket 700-HN122, 700-HN222, 700-HN224 700-HN122, 700-HN222, 700-HN224 110V DC 700-HK32Z1 (1) Options Pilot Light: Add suffix (-4) to the selected 700-HK Relay catalog number except for the 240V AC units, add (-4L). Manual Operator and LED: Add suffix (-3-4) to the selected 700-HK Relay catalog number, except for the 240V AC units, add (-3-4L). AgNi Contact with Gold plating: Replace"3"with "X"om catalog number. For example, if catalog number 700-HK36A1 is required with gold plating, the new catalog number is 700-HKX6A1. For high inductive, Tungsten, or Capacitive load applications, replace the"3"with a "M"in the catalog number. Only available in a SPDT configuration and with 24V DC, 120V AC, or 240V AC coil voltages. 44 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Accessories- 700-HK Relays Photo Description Relay and Timer Specifications Pkg. Qty. Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting 5-blade miniature socket with 10 A rating for use with 1-pole, 700-HK relays. Accepts forked lug conductors. Socket includes a retainer clip. 10 700-HN121 Screw Terminal Socket -- Panel or DIN Rail Mounting 5-blade miniature socket with 16 A rating for use with 1-pole, 700-HK relays. Retainer clips are packaged separately with socket. Guarded terminal 10 construction and compatible with optional plug-in module accessories. Spring Clamp Terminal Socket -- Panel or DIN Rail Mounting 5-blade miniature socket for use with 1-pole, 700-HK relays. 10 700-HN221 700-HN223 Screw Terminal Socket -- Panel or DIN Rail Mounting 8-blade miniature socket with 5 A rating for use with 2-pole, 700-HK relays. Accepts forked lug conductors. This socket includes a retainer clip. 10 700-HN122 Screw Terminal Socket -- Panel or DIN Rail Mounting 8-blade miniature socket with 8 A rating for use with 2-pole, 700-HK relays. Retainer clips are packaged separately with socket. Guarded terminal construction and compatible with optional plug-in module 10 accessories. Spring Clamp Terminal Socket -- Panel or DIN Rail Mounting 8-blade miniature socket for use with 2-pole 700-HK relays. 10 700-HN222 700-HN224 Flange Mount Adapter Used for panel-mounting bulletin 700-HK relays. Order must be for 10 adapters or multiples of 10. 10 700-HN226 35 mm Rail Mount Adapter Mounts bulletin 700-HK relays to a 35 mm rail. Order must be for 10 adapters or multiples of 10. 10 700-HN227 Socket Retainer Clip and Ejection Lever For use with 700-HN22, -HN222, -HN223, and -HN224 sockets. Orders must be for 10 clips or multiples of 10. 10 700-HN229 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 45 Relay and Timer Specifications Specifications- 700-HK Relays Attribute Rated Thermal Current (Ith) Rated Insulation Voltage (Ui) Inductive V AC Contacts Inductive V DC Resistive Make, Break , and Continuous Min. Permissible Contact Ratings Permissible Coil Voltage Variation Power Consumption Coil Voltages Pickup: holding Voltage: Must Dropout Voltage: Dielectric Withstand Voltage Poleto Pole(VRMS) Contact to Coil (VRMS) Degree of Protection Mechanical Life Operations Electrical Lifecycles Switching Frequency Operating Time at Nominal Pickup Voltage at 20 °C (ms) Dropout Vibration Operational Non-Operational Shock Operational Non-Operational Temperature Altitude Operating Storage Insulating Material Enclosure Contact Material Terminal Markings on Socket 700-HK 120V AC 240V AC 230V AC 24V DC 125V DC 250V DC 230V AC 277V AC Electrical Ratings 1-Pole, 1 CO, SPDT -- 16 A 250V IEC, 300V UL/CSA AC-15, 6.2 A B300 Pilot Duty, 3 A A300 (700-HKM_) 1/3 Hp (0.24 kW) 1-phase 120V AC AC-15, 3.1 A B300 Pilot Duty, 1.5 A A300(700-HKM_) 3/4 Hp (0.55 kW), 1-phase 240V AC 0.55 kW, 1-phase 230V AC DC-13, 5.0 A 24V DC DC-13, 0.2 A / R300 Pilot Duty, 0.22 A 125V DC DC-13, 0.1 A / R300 Pilot Duty, 0.11 A 5 A, 250V AC AC-1, 16 A 230V AC 16 A, General Use 277V AC 2-Pole, 2 CO, DPDT -- 8 A AC-15, 2.9 A B300 Pilot Duty, 3.0 A 1/4 Hp (0.18 kW), 1-phase AC-15, 1.4 A B300 Pilot Duty, 1.5 A 1/2 Hp (0.37 kW), 1-phase 0.37 kW, 1-phase DC-13, 3.0 A DC-13, 0.2 A / R300 Pilot Duty, 0.22 A DC-13, 0.1 A / R300 Pilot Duty, 0.11 A AC-1, 8 A 8 A, General Use 30V DC DC-1, 12 A / 10 A, Resistive 30V DC DC-1, 6 A / 6 A, Resistive 300 mW (5V/60 mA or 60V/5 mA) for AgNi Contacts (700-HK3_) 50 mW (5V/10 mA or 25V/2 mA) for AgNi + Gold Contacts (700-HKX_) 500 mW (100V/5 mA or 5V/100 mA) for AgSnO2 Contacts (700-HKM_) 80...110% of Nominal Voltage at 50/60 Hz, 73...110% of Nominal Voltage at DC 80% of Nominal V AC at 50/60 Hz, 40% of Nominal V DC 20% of Nominal V AC at 50/60 Hz, 10% Nominal V DC 1.2V A (V AC Coils), 0.5 W (V DC Coils) See Overview/Product Selection Design Specification/Test Requirements 2000V AC 4000V AC Mechanical IP 20 (guarded terminal sockets), RT II -- Flux-proof (Relay) 10 x 106 230V AC, 16 A Resistive: 100 000 min. 277V AC, 16 A Resistive: 30 000 min. 30V DC, 10 A Resistive: 30 000 min. B300, R300, Hp (kW): 6000 min. A300 (700-HKM_): 100,000 min. 230V AC, 8 A Resistive: 100 000 min. 277V AC, 8 A Resistive: 30 000 min. 30V DC, 6 A Resistive: 30 000 min. B300, R300, Hp (kW): 6000 min. Mechanical: 18,000 cycles/hr. Electrical: 900 cycles/hr. 15 ms 5 ms 10...2000 Hz, 0.76 mm (0.03 in.) 2.5 G 10...2000 Hz, 0.76 mm (0.03 in.) 5.0 G 15 G 50 G Environmental 40...+70 °C (40...+158 °F) 40...+85 °C (40...+185 °F) 2000 m (6560 ft) Construction Molded High Dielectric Material Transparent Dust Cover 700-HK3_: Silver nickel (AgNi); 700-HKX_: Silver Nickel + Gold Plating (AgNi + Au); 700-HKM_: Silver Tin Oxide(AgSnO2) In accordance with EN 50005 46 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Attribute Sockets Screw Terminal Spring Clamp Certifications Standards Dimensions- 700-HK Relays 700-HK 1-Pole 2-Pole 700-HN121 (10 A @ 70 °C) 700-HN221 (16 A @ 50 °C, 12 A @ 70 °C) 700-HN122 (2 x 5 A @ 70 °C) 700-HN222 (2 x 8 A @ 70 °C) 700-HN223 (15 A @ 40 °C with 2 conductors per terminal) (10 A @ 70 °C with 1 conductor per terminal) 700-HN224 (2 x 8 A@ 70 °C) Approvals CSA Certified, File 75088, UL Recognized, File E3125 Guide NLDX2/NLCX8, cULus Listed with Allen-Bradley sockets (File No. 3125 Guide NLDX/NLDX7), CE Marked EN61810-1, CSA 22.2 No. 14, UL 508 Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 12.4 29.0 (1/2) (1-9/64) 12.4 29.0 (1/2) (1-9/64) 32.8 (1-19/64) 30.1 (1-3/16) 6.5 (1/4) 4.75 (3/16) A1 5 0.5 (1/32) COM 11 4 A2 1 NC 12 NO 14 2 3 Cat. No. 700-HK36_ (SPDT) COM 11 NO 14 NC 12 3 4 2 COM 21 NO 24 NC 22 6 5 7 Cat. No. 700-HN224 A1 8 15.8 (5/8) A2 1 COM 11 NO 14 NC 12 A1 4 3 2 5 15.8 (5/8) A2 1 Cat. No. 700-HN223 32.8 (1-19/64) 30.1 (1-3/16) 6.5 (1/4) 2.5 (3/32) 0.5 (1/32) COM 11 A1 NC 12 3 NO 14 8 2 4 A2 NC 22 NO 24 17 5 COM 21 6 Cat. No. 700-HK32_ (DPDT) COM 11 NO 14 NC 12 3 42 A1 8 15.8 (5/8) COM 21 NO 24 NC 22 A2 6 57 1 Cat. No. 700-HN222 COM 11 NO 14 NC 12 4 3 2 A1 5 15.8 (5/8) A2 1 Cat. No. 700-HN221 44.7 (1-3/4) 32.5 22.6 (1-9/32) (57/64) 34.7 (1-3/8) 95.6 (3-49/64) Cat. No. 700-HN223, 700-HN224 Wire Size: 0.2 mm2...1.5 mm2 (#24 AWG....#14 AWG) Either Solid or Stranded Strip Length: 8 mm (5/16 in) 64.9 (2-9/16) 35.3 (1-25/64) 35.4 (1-13/32) 82.85 (3-17/64) Cat. No. 700-HN221, 700-HN222 Wire Size: 0.2 mm2...2.5 mm2 (#24 AWG....#12 AWG) Either Solid or Stranded Strip Length: 8 mm (5/16 in), Torque: 0.8Nm (7.0 lb.-in.) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 47 Relay and Timer Specifications Dimensions - 700-HK Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 3.6 (9/64) 46.0 (1-13/16) 38.0 (1-1/2) 14.4 (37/64) 46.9 (1-27/32) 14.4 (37/64) 36.6 (1-11/16) 2.0 (5/64) 18.1 (23/32) Cat. No. 700-HN226 42.4 (1-43/64) 39.8 (1-37/64) 34.8 (1-3/8) Cat. No. 700-HN227 Cat. No. 199-DR1 199-DR4 5.2 (13/64) A 35 (1-3/8) 35 (1-3/8) 50 (1-63/64) 12.5 6.2 (1/2) (15/64) 1.0 (0.04) 35.0 (1.38) 27.0 (1.06) 1000 (39-3/8) 7.5 (0.30) Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes Cat. No. 199-DR1 DIN Mounting Rail Series B B C D 27 7.5 1.02 (1-1/16) (19/64) (1/64) 27 15 2.3 (1-1/16) (19/32) (3/32) Approx. Shipping Wt. 1.85 kg (4.07 lb) (10/pkg) 3.68 kg (8 lb) (5/pkg) 48 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 7.11 11 (9/32) Five M3.5 4 x 0.315 Screws 14 3 84.1 (3-5/16) 12 2 3.0 Ø (1) (1/8) Use M3 Screws 5 (+) (A1) 1 (-) (A2) 2.03 (5/64) 4.06 (5/32) 39.5 (1-17/32) 35.5 (1-13/32) 21 6 22 7 24 5 84.1 (3-5/16) 8 (+) (A1) 7.11 (9/32) 11 3 Eight M3.5 x 0.315 Screws 12 14 2 4 3.0 Ø (1) (1/8) Use M3 Screws 4.06 (5/32) 15.6 (5/8) 29.9 (1-3/16) 54.1 (2-1/8) 4.06 (5/32) 1 (-) (A2) 15.6 (5/8) 2.03 (5/64) 4.06 (5/32) 39.5 (1-17/32) 35.5 (1-13/32) 29.9 (1-3/16) 54.1 (2-1/8) Cat. No. 700-HN121 Wire Size: 2 x 2.5 mm2 Single Wire Up to #14 AWG Double Wire 2 x 2.5 mm2 (14 AWG... 20 AWG) Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Cat. No. 700-HN122 Wire Size: 2 x 2.5 mm2 Single Wire Up to #14 AWG Double Wire 2 x 2.5 mm2 (14 AWG... 20 AWG) Qty. 2 wires (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 49 Relay and Timer Specifications 700-HL Terminal Block Relay · Relay and socket assembled interface modules for high density interposing or isolation applications · Screw terminal and spring-clamp bases · 6 A relay, choice of silver or gold contacts · 2 A solid-state relay -- DC output · 2 A solid-state relay -- AC output · SPDT (relay), 1 N.O. (solid-state) · Built-in retainer clip and snap-in marker lever · Standard LED, reverse polarity protection, and surge protection · Externally replaceable relay modules · Unique leakage current suppression version to address industry concerns of nuisance coil turn-on or contact non-drop out when connecting to PLCs with leakage current · Available with hazardous location certification Standard built-in Features: · LED · Reverse Polarity Protection for DC Inputs · Coil Surge Protection(1) Cat. No. 700-HLT1Z24 Specifications Cat. No. 700-HLT2Z24 Cat. No. 700-HLS1Z24 (3) Cat. No. 700-HLS11Z24 Output Type Recommended Tightening Torque Wire Range SPDT (1 C/O); Ith = 6A(2) 1 N.O. solid-state; Ith = 2 A, 24V DC or Ith = 2 A, 240V AC 0.5 N· m max. (4.4 lb· in) Screw Terminal: 0.14 mm2...2.5 mm2 (#26...#14 AWG), Spring Terminal: 0.2 mm2...2.5 mm2 (#24...#14 AWG) Approvals UL, cULus, cURus, ABS, CE (1) Diode surge protection provided. (2) For Gold-plated contacts: Add the letter"X"at the end of the catalog number. For example: if Cat. No. 700-HLT1Z24 is required with gold plating, the new cat. no. is 700-HLT1Z24X. (3) Reverse polarity on the output terminals of the solid-state relay will result in the output being "ON" regardless of the state of the input voltage. Input Voltage 12V DC 24V DC 48V DC 12V AC/DC 24V AC/DC 48V AC/DC 110/125V AC/DC 220...240V AC/DC 240V AC Pkg. Qty. Cat. No. (Screw Terminals) Cat. No. (Spring Clamp Terminals) 10 (2) 700-HLT1Z12 700-HLT2Z12 10 (2) 700-HLT1Z24 700-HLT2Z24 10 (2) 700-HLT1Z48 700-HLT2Z48 10 700-HLT1U12 700-HLT2U12 10 700-HLT1U24 700-HLT2U24 10 700-HLT1U48 700-HLT2U48 10 700-HLT1U1 700-HLT2U1 10 700-HLT1U2 700-HLT2U2 10 700-HLT1A2 -- Cat. No. Pkg. Quantity (Screw Terminals) (DC Output) -- -- 10 (2) 700-HLS1Z24 10 (2) 700-HLS1Z48 -- -- -- -- -- -- 10 (2) 700-HLS1U1 10 (2) 700-HLS1U2 -- -- Cat. No. (Spring Clamp Terminals) (DC Output) -- 700-HLS2Z24 700-HLS2Z48 -- -- -- 700-HLS2U1 700-HLS2U2 -- Cat. No. (Screw Terminals) (AC Output) -- 700-HLS11Z24 700-HLS11Z48 -- -- -- 700-HLS11U1 700-HLS11U2 -- 50 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Input Voltage Pkg. Qty. Cat. No. (Screw Terminals) Cat. No. (Spring Clamp Terminals) Built-in LCSC (leakage current suppression circuit) 10 120V AC and 125V DC(1) (2) 700-HLT1L1 -- Built-in LCSC (leakage current suppression 10 circuit) 240V AC (1) (2) 700-HLT1L2 -- Hazardous Location Certification 24V DC 10 700-HLT1Z24-EX -- Hazardous Location Certification 12V DC 10 700-HLT1Z12-EX -- Hazardous Location Certification 110/125V 10 AC/DC 700-HLT1U1-EX -- (1) Leakage current suppression up to 2.2 mA off state current. (2) Electromechanical relay to solid-state relay interchangeability is possible. Cat. No. Pkg. Quantity (Screw Terminals) (DC Output) Cat. No. (Spring Clamp Terminals) (DC Output) 10 (2) 700-HLS1L1 -- 10 (2) 700-HLS1L2 -- 10 700-HLS1Z24-EX -- 10 -- -- 10 700-HLS1U1-EX -- Accessories - 700-HLT, -HLS Relays Photo Description Replacement Relays(1) Order must be for 20 relays or multiples of 20. Pkg. Quantity Socket Input Voltage 12V AC/DC 24V AC/DC 20 48V AC/DC 110/125V AC/DC 220...240V AC/DC Replacement SSR 4-blade miniature relay for use with 1 N.O. SSR DC output. 20 Order multiples of 20. 24V DC 48V DC, 110/125V AC/DC 220...240V AC/DC Replacement SSR 4-blade miniature relay for use with 1 N.O. SSR AC output. 20 Order multiples of 20. 24V DC Replacement SSR 4-blade miniature relay for use with 1 N.O. SSR AC output. 20 Order must be for 20 relays or multiples of 20. 20-Way Jumper Can be cut to required length. Ith = 36 A max per 20-way jumper. 1 48V DC 110/125V AC/DC 220...240V AC/DC Color Red Grey Blue Cat. No. (Screw Terminals) (AC Output) 700-HLS11L1 700-HLS11L2 -- -- -- Cat. No. 700-TBR12 700-TBR24 700-TBR48 700-TBR60 700-TBS24 700-TBS60 700-TBS124 700-TBS160 700-TBJ20R 700-TBJ20G 700-TBJ20B Rockwell Automation Publication 700-TD552F-EN-P - January 2021 51 Relay and Timer Specifications Photo Description End Barrier Used for visual inspection of groups, safe separation of neighboring 700-HL modules that end with jumpers. Pkg. Quantity Socket Input Voltage 10 Black Snap-in Marker These snap-in markers have a 6 x 10 mm surface and snap into the ejection lever for the relay. For custom markers, contact your local 100 Rockwell Automation sales office or Allen-Bradley distributor for more information. Blank (1) For gold-plated contacts: Add the letter"X"at the end of the catalog number. For example: if Cat. No. 700-TBR24 is required with gold plating, the new cat. no. is 700-TBR24X. Dimensions - 700-HL Relays Cat. No. 700-HN177 1492-MC6X10 700-HL Spring Terminal Design Single Wire: 0.2 mm2...2.5 mm2 (#24 AWG...#14 AWG ) Wire Type: Solid or stranded, copper only.Strip Length: 9 mm (11/32 in.) Cat. No. 199-DR1 DIN Mounting Rail Series B, Cat. No. 199-DR4 DIN Mounting Rail Series B has no mounting holes. Specifications - 700-HLT Relays Pilot Duty Rating Rated Thermal Current (Ith) Rated Insulation Voltage(Ui) Contacts Inductive Load 52 Cat. No. 700-HLT... (Relay Output) Electrical Ratings B 300, R 300 1-Pole -- 6 A 250V IEC, 300V UL/CSA 1-Pole 24V AC, 1-phase 30 A 5 A Inductive V AC 120VAC, 1-phase 30 A 3 A Make Break 240VAC, 1-phase 15 A 1.5 A Inductive V DC Resistive Make, Break, and Continuous 24V DC 125V DC 240V DC 24V DC 250V AC 240V DC DC-13, 1.0 A DC-13, 0.2 A DC-13, 0.1 A 6.0 A 6.0 A 0.1 A AC-15 250V, 3 A N.O. Contact, 1.5 A N.C. Contact DC-13 24V, 1 A N.O., and N.C. Contact Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Cat. No. 700-HLT... (Relay Output) Min. Permissible Contact Ratings 12V, 6 mA (72 mW) for Silver Contacts, 8V, 2.5 mA (20 mW) for Gold Contacts Permissible Coil Voltage Variation Pickup: 85...110% of Nominal Voltage at 50 Hz 85...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC Must Dropout 10% of Nominal Voltage at AC Voltage: 5% of Nominal Voltage at DC Power Consumption ±10% AC DC 0.3VA 0.2 W Design Specification / Test Requirements Pole to Pole (VRMS) 1000V Dielectric Withstand Voltage Contact to Coil (VRMS) 4000V Input Voltage 12V AC/DC 24V AC/DC 48V AC/DC 120V AC/DC 240V AC/DC 120VLCSC 240VLCSC Impedance (Ohms) 1K 2 K 6 K 26 K 56 K 16 K 35 K Mechanical Degree of Protection Mechanical Life Operations IP20 1 x 107 Electrical Life Operations 6 A Resistive: 100 000 min. 24V DC, 1 A Inductive: 200 000 min. 120V AC 1 A Inductive: 300 000 min. Switching Frequency Operations (no-load) 10 cycles/sec Coil Voltages See Overview/Product Selection Pickup 7 ms Operating Time at Nominal Voltage at 20 °C (ms) Dropout 3 ms Maximum Operating Rate (full load = 6 A) 6 cycles/min. Coil Surge Protection Per EN 61000-4.5; Surge Immunity (801-5) Class III: 2 kV common and 1 kV differential mode Environmental Temperature Operating Storage 40...+55 °C 40...+100 °C Altitude 2000 m (6560 ft) Construction Insulating Material Molded High Dielectric Material Enclosure Relay IP67 Contact Material Terminal Markings on Socket Silver Tin Ox, AgSnO2 or Silver with Gold Plating, AgSnO2 + Au In accordance with EN50 0005 Certifications cULus Listed (File No. E3125, E14843 Guide NLDX/NLDX7) with Allen-Bradley socket, CE Marked, ABS (American Bureau of Shipping) Standards EN 61810-1, CSA 22.2,UL 508,NEMA IEE MAC Compliant, ICS-2 Compliant Class 1, Zn 2, Groups IIC, Ex nC IIC T5 Ta < 55 °C Hazardous Location Approvals UL Listed (UL 60079-15) CSA Certified (1) (CAN/CSA E60079-15) 700-HLT1Z12-EX (12V DC supply) 700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply) 700-HLT1U1-EX, 700-HLS1U1-EX (110V/125V AC/DC supply) 700-HLT1Z12-EX (12V DC supply) 700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply) (1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%. Rated Thermal Current (Ith) Rated Insulation Voltage(Ui) Cat. No. 700-HLS... (Solid-state Output) Electrical 2 A (DC output) 250V IEC, 300V UL/CSA 2 A (AC output) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 53 Relay and Timer Specifications Cat. No. 700-HLS... (Solid-state Output) Min. Control Voltage 80% nominal voltage Maximum Control Voltage 110% nominal voltage Control Circuit Control Current Release Voltage 9 mA ±10% (24V) 4 mA ±10% (120/240V) 0.4 x nominal voltage (24V), 0.35 x nominal voltage (120/240V) Min. Control Circuit Resistance 3200 ohms (24V), 16k ohms (120V), 32k ohms (240V) 2500 ohms (24V), 12k ohms (120V), 24k ohms (240V) Load Voltage Range 0...24V DC 24...240V AC Max. Repetitive Blocking Voltage 33V 600V Outputs Max. Switching Current (inductive/ resistive) On State Voltage Drop @ Max. Switching Current 2 A DC <120 mV DC 1 A AC <1V AC Leakage Current max. 100 A (@U = 24V) AC Power Consumption ±10% DC 0.6VA(120V),1VA(240V) 0.2 W 0.3 W Design Specification/Test Requirements Pole to Pole (VRMS) 2500V Dielectric Withstand Voltage Contact to Coil (VRMS) 2500V Input Voltage 24V DC 48V DC 120V AC/DC 240V AC/DC 120V LCSC 240V LCSC Impedance (Ohms) 2K 9 K 26 K 58 K 16 K 35 K Mechanical Degree of Protection IP20 Input Voltages See Overview/Product Selection Operating Time at Nominal Voltage at Turn on Time 20 °C (ms) Drop Out Time 30 s (DC only input voltage), 7 ms (AC/DC input voltage) 350 s (DC only input voltage), 10 ms (AC/DC input voltage) Maximum Operating Rate 300 Hz Environmental Temperature Operating Storage 20...+55 °C 40...+70 °C Altitude 2000 m (6560 ft) Construction Insulating Material Molded High-Dielectric Material Enclosure Relay IP67 Terminal Markings on Socket In accordance with EN50 0005 Certifications cULus Listed (File No. E14843, Guide NLDX/NLDX7), CE Marked, ABS (American Bureau of Shipping) Standards UL 508, CSA C22.2 No. 14, EN 61810-1 Class 1, Zn 2, Groups IIC, Ex nC IIC T5 Ta < 55 °C Hazardous Location Approvals UL Listed (UL 60079-15) CSA Certified (1) (CAN/CSA 60079-15) 700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply) 700-HLT1U1-EX, 700-HLS1U1-EX (110V/125V AC/DC supply) 700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply) (1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%. 54 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700-HLT, -HLS Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 76.0 (2.99) 76.0 (2.99) 88.0 (3.46) 6.2 (0.24) 93.0 (3.66) 6.2 (0.24) 700-HLT / -HLS Screw Terminal Design Single Wire: 0.14 mm2...2.5 mm2 (#26 AWG...#14 AWG) Double Wire: 2 x 0.14 mm2...2 x 1.5 mm2 (2 x #26 AWG...2 x #16 AWG) Wire Type: Solid or stranded, copper only Strip Length: 9 mm (11/32 in). Torque: 0.5 N·m (4.4 lb·in) 700-HLT / -HLS Spring Terminal Design Single Wire: 0.2 mm2...2.5 mm2 (#24 AWG...#14 AWG) Wire Type: Solid or stranded, copper only Strip Length: 9 mm (11/32 in.) Dimensions - 700-HLT, -HLS Relay Accessories 5.2 (13/64) 50 (1-63/64) 6.2 12.5 (15/64) (1/2) 1.0 (0.04) 35.0 (1.38) 27.0 (1.06) 1000 7.5 (39-3/8) (0.3) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes Cat. No. 199-DR1 199-DR4 A 35 (1-3/8) 35 (1-3/8) B 27 (1-1/16) 27 (1-1/16) C 7.5 (19/64) 15 (19/32) D 1.02 (1/64) 2.3 (3/32) Approx. Shipping Wt. 1.85 kg (4.07 lb) 3.68 kg (8 lb) Pkg. Qty. 10/pkg 5/pkg Rockwell Automation Publication 700-TD552F-EN-P - January 2021 55 Relay and Timer Specifications 700-HL 2-pole Terminal Block Relay · Relay and socket assembled interface modules for high density interposing or isolation applications · Screw terminal and spring-clamp bases · 10 A relay, choice of silver or gold contacts · DPDT (relay) · Built-in retainer clip and snap-in marker lever · Standard LED, reverse polarity protection, and surge protection · Externally replaceable relay modules Output Type Recommended Tightening Torque Wire Range Approvals DPDT (2 C/O); Ith = 10 A 0.6 N·m max. (5.3 lb·in.) Screw Terminal: 0.2...2.5 mm2 (#24...14 AWG), Spring Terminal: 0.2...2.5 mm2 (#24...14 AWG) cULus, cURus, CE Input Voltages Pkg. Quantity Cat. No.(1) (Screw Terminals) Cat. No.(Spring Clamp Terminals) 12V DC 10 700-HLT12Z12 700-HLT22Z12 24V DC 10 700-HLT12Z24 700-HLT22Z24 48V DC 10 700-HLT12Z48 700-HLT22Z48 24V AC/DC 10 700-HLT12U24 700-HLT22U24 110/125V AC/DC 10 700-HLT12U1 700-HLT22U1 220...240V AC/DC 10 700-HLT12U2 700-HLT22U2 (1) For Gold-plated contacts: Add the letter "X" at the end of the catalog number. Example: Cat. No. 700-HLT12Z24 with gold plated contacts is Cat. No. 700-HLT12Z24X. The following relays are available with the gold-plated contact option: 700-HLT_2Z24, 700-HLT_2U24, 700-HLT_2U1, and 700-HLT_2U2. Not available on 12V and 48V DC products. Accessories - 700-HL Relays (2- pole) Photo Description Pkg. Qty. Replacement Relays Order must be for 20 relays or multiples 20 of 20. 8-Way Jumper Can be cut to required length. Ith = 1 10 A max per 8-way jumper. Socket Input Voltage/Color 12V DC 24V AC/DC 48V DC 110/125V AC/DC, 220...240V AC/DC Red Grey Blue End Barrier Used for visual inspection of groups, safe separation of neighboring 700-HL 10 Black modules that end with jumpers. Snap-in Marker(1) These snap-in markers have a 6 x 12 mm surface and snap into the ejection 100 Blank lever for the relay. (1) For custom markers, contact your local Rockwell Automation sales office or Allen-Bradley distributor for more information. Cat. No. 700-TBR212 700-TBR224 700-TBR248 700-TBR2110 700-TBJ08R 700-TBJ08G 700-TBJ08B 700-HN177 1492-MS6X12 56 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-HL Relays (2-Pole) Pilot Duty Rating Rated Thermal Current (Ith) Rated Insulation Voltage(Ui) Cat. No. 700-HLT...2-Pole (Relay Output) Electrical Ratings B 300, R 300 2-Pole -- 10 A 250V IEC, 300V UL/CSA Contacts Min. Permissible Contact Ratings Permissible Coil Voltage Variation Dielectric Withstand Voltage Input Voltage Impedance (Ohms) Power Consumption ±10% Degree of Protection Mechanical Life Operations Electrical Life Operations Switching Frequency Operations (no-load) Coil Voltages Operating Time at Nominal Voltage at 20 °C (ms) Maximum Operating Rate (full load = 6 A) Inductive V AC UL 120V AC 240V AC AC-15, 3.0A B 300, 3.0 A AC-15, 3.0 A B 300, 1.5 A 1/4 HP (186 W), 1-phase 1/2 HP (373 W), 1-phase 24V DC DC-13, 2.0 A Inductive V DC 125V DC DC-13, 0.3 A 250V DC DC-13, 0.2 A 250V AC 10 A Resistive Make, Break, and 24V DC 10 A Continuous 250V DC 0.28 A 12V, 10 mA (120 mW) for Silver Contacts, 5V, 1 mA (50 mW) for Gold Contacts Pickup: 85...110% of Nominal Voltage at 50 Hz 85...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC Must Dropout Voltage: 10% of Nominal Voltage at AC 5% of Nominal Voltage at DC Design Specification/Test Requirements Pole to Pole (VRMS) 1000V Contact to Coil (VRMS) 5000V Adjacent Contacts 2500V (VRMS) 12V AC/DC 24V AC/DC 48V DC 120V AC/DC 240V AC/DC 1 K 2 K 3 K 34 K 72 K AC N/A 0.5V A N/A 0.4V A 0.8V A DC 0.4 W 0.5 W 0.8 W 0.5 W 0.7 W Mechanical IP20 3 x 107 250V AC/24V DC, 8 A Resistive: 100 000 min. 24V DC, 10 A Resistive: 6000 min. 250V DC, 0.28 A Resistive: 6000 min. 250V AC, 10 A Resistive: 30 000 min. 1200 cycles/sec See Overview/Product Selection Pickup typical 10 ms Dropout typical 10 ms 6 cycles/min. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 57 Relay and Timer Specifications Cat. No. 700-HLT...2-Pole (Relay Output) Temperature Environmental Operating Storage 40...+60 °C 40...+100 °C Altitude 2000 m (6560 ft) Insulating Material Construction Molded High-Dielectric Material Enclosure Relay RT II -- flux-proof, pollution degree 2 installation environment Contact Material AgNi 90/10 or AgNi 90/10 + Au Terminal Markings on Socket In accordance with EN50 0005 Certifications cULus Listed (File No. E3125, Guide NRNT/NRNT7), CE Marked Standards UL 508, CSA C22.2 No. 14, EN 61810-1 Dimensions - 700-HL (2-pole) Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 87.7 (3.45) 14 (0.55) 92.8 (3.65) 14 (0.55) 75 (2.95) 75 (2.95) Bulletin 700-HL Screw Terminal Design Single Wire: 0.14 mm2...2.5 mm2 (#26 AWG...14 AWG) Double Wire: 2 x 0.14 mm2...2 x 1.5 mm2 (2 x #26 AWG...2 x 16 AWG) Wire Type: Solid or stranded, copper only Strip Length: 9 mm (11/32 in). Torque: 0.5 N·m (4.4 lb·in) Bulletin 700-HL Spring Terminal Design Single Wire: 0.2 mm2...2.5 mm2 (#24 AWG...#14 AWG) Wire Type: Solid or stranded, copper only Strip Length: 9 mm (11/32 in) 97.8 (3.85) Bulletin 700-TBJ08_ 8-Way Jumper 58 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Cat. No. 199-DR1 199-DR4 5.2 (13/64) A 35 (1-3/8) 35 (1-3/8) 50 (1-63/64) 6.2 12.5 (15/64) (1/2) 1.0 (0.04) 35.0 (1.38) 27.0 (1.06) 1000 7.5 (39-3/8) (0.3) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes B C D 27 7.5 1.02 (1-1/16) (19/64) (1/64) 27 15 2.3 (1-1/16) (19/32) (3/32) Approx. Shipping Wt. 1.85 kg (4.07 lb) (10/pkg) 3.68 kg (8 lb) (5/pkg) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 59 Relay and Timer Specifications 700-HLF Terminal Block Timing Relay · Relay and socket assembled modules for high-density applications · Screw terminal bases · 6 A relay, choice of silver or gold contacts · SPDT (relay) · Four timing functions · Time range from 0.1 sec...6 hr · Built-in retainer clip and snap-in marker lever · Standard LED, reverse polarity protection, and surge protection · Externally replaceable relay modules Wiring Diagram A2 A1 16 15 18 Output Type Recommended Tightening Torque Wire Range Approvals SPDT (1 C/O); Ith = 6A§ 0.5 N·m max. (4.4 lb·in) Screw Terminal: 0.14 mm2...2.5 mm2 (#26...#14 AWG) cULus, cURus, CE Assembled Device Input Voltage 24V AC/DC (1) For gold-plated contacts add an X after the catalog number listed. Pkg. Quantity 10 Accessories - 700-HLF Relays Terminal block timing relay bases are not sold separately. Photo Description Cat. No.(1) 700-HLF1U24 Pkg. Quantity Socket Input Voltage Cat. No. Replacement Relays Order must be for 20 relays or multiples of 20. 20 24V AC/DC 700-TBR24(1) 20-Way Jumper Can be cut to required length. Ith = 36 A max per 20-way 1 jumper. End Barrier Used for visual inspection of groups, safe separation of 10 neighboring 700-HL modules that end with jumpers. Color Red 700-TBJ20R Grey 700-TBJ20G Blue 700-TBJ20B Black 700-HN177 Snap-in Marker These snap-in markers have a 6 x 10 mm surface and snap into 100 Blank the ejection lever for the relay. (1) For gold-plated contacts: Add the letter"X"at the end of the catalog number. For example: if Cat. No. 700-TBR24 is required with gold plating, the new cat. no. is 700-TBR24X. 1492-MC6X10 60 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Function and Connection Diagrams - 700-HLF Relays Relay and Timer Specifications U (A1/A2) R t LED U (A1/A2) t R LED U (A1/A2) R LED t 0.5s U (A1/A2) t R LED tt A1 A2 On-Delay A1 A2 One Shot A1 A2 Pulse A1 A2 Flasher 15 1 c/o (SPST) 18 16 15 1 c/o (SPST) 18 16 15 1 c/o (SPST) 18 16 15 1 c/o (SPST) 18 16 Specifications- 700-HLF Relays Pilot Duty Rating Rated Thermal Current (Ith) Rated Insulation Voltage (Ui) Contacts Inductive Load Min. Permissible Contact Ratings Cat. No. 700-HLF... (Relay Output) (1) Electrical Ratings B 300, R 300 1-Pole -- 6 A 250V IEC, 300V UL/CSA Inductive 1-Pole 24V AC, 1-phase 30 A 5 A 120VAC, 1phase 30 A 3 A 240VAC, 1phase 15 A 1.5 A 24V DC 1.0 A Make, Break and Continuous V DC 120V DC 0.2 A 240V DC 0.1 A AC-15 250V, 3 A N.O. Contact, 1.5 A N.C. Contact DC-13 24V, 1 A N.O. and N.C. Contact 12V, 6 mA (72 mW) for Silver Contacts, 8V, 2.5 mA (20 mW) for Gold Contacts Rockwell Automation Publication 700-TD552F-EN-P - January 2021 61 Relay and Timer Specifications Permissible Coil Voltage Variation Pickup: 85...110% of Nominal Voltage at 50 Hz 85...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC Must Dropout Voltage: 10% of Nominal Voltage at AC, 5% of Nominal Voltage at DC Power Consumption ±10% AC/DC 0.5VA Design Specification/Test Requirements Pole to Pole (VRMS) 1000V Dielectric Withstand Voltage Contact to Coil (VRMS) 4000V Input Voltage 24V AC/DC Impedance (Ohms) 2 K Mechanical Degree of Protection Mechanical Life Operations IP20 1 x 107 Electrical Life Operations 6 A Resistive: 100,000 min. 24V DC, 1 A Inductive: 200,000 min. 120V AC 1 A Inductive: 300,000 min. Switching Frequency Operations (no-load) 10 cycles/sec Coil Voltages See Overview/Product Selection Timer Functions On-Delay, One Shot, Pulse, and Flasher Timer Settings 0.1...3 s, 3...60 s, 1...20 min, and 0.3...6 hr Timer Adjustments Min and Max adjustments with Potentionmeter Timer Accuracy Repeatability 1%, Recovery Time < 50 ms, Setting Accuracy Full Range 5% Coil Surge Protection Per EN 61000-4.5; Surge Immunity (801-5) Class III: 2 kV common and 1 kV differential mode Environmental Temperature Operating Storage 40...+55 °C (40...+131 °F) 40...+100 °C (40...+212 °F) Altitude 2000 m (6560 ft) Construction Insulating Material Molded High Dielectric Material Enclosure Relay IP67 Contact Material Terminal Markings on Socket Silver Tin Ox, AgSnO2 or Silver with Gold Plating, AgSnO2 + Au In accordance with EN50 0005 Certifications cULus Listed (File No. E3125, Guide NLDX/NLDX7) with Allen-Bradley socket, CE Marked Standards EN60947-4-1,EN60947-5-1,CSA 22.2,UL 508,NEMA IEE MAC Compliant, ICS-2 Compliant (1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%. 62 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions- 700-HLF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 6.20 (0.24) 76.0 (2.99) 88.0 (3.46) 5.2 (13/64) Cat. No. 199-DR1 199-DR4 A 35 (1-3/8) 35 (1-3/8) 700-HLF Screw Terminal Design Single Wire: 0.14 mm2...2.5 mm2 (#26 AWG...14 AWG) Double Wire: 2 x 0.14 mm2...2 x 1.5 mm2 (2 x #26 AWG...2 x 16 AWG) Wire Type: Solid or stranded, copper only Strip Length: 9 mm (11/32 in.). Torque: 0.5 N·m (4.4 lb·in) 50 (1-63/64) 6.2 12.5 (15/64) (1/2) 1.0 (0.04) 35.0 (1.38) 27.0 (1.06) 1000 7.5 (39-3/8) (0.3) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes B 27 (1-1/16) 27 (1-1/16) C 7.5 (19/64) 15 (19/32) D 1.02 (1/64) 2.3 (3/32) Approx. Shipping Wt. 1.85 kg (4.07 lb) (10/pkg) 3.68 kg (8 lb) (5/pkg) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 63 Relay and Timer Specifications 700-HP Slim Line Relay · 8 A contact ratings · DPDT/ (2 c/o) contacts · Plug-in PIN style (PCB) terminals (5 mm pinning) · Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts · Available with mechanically linked contacts (Type B) · Safety Control Relay Version (700-HPS) Photo Description Contact Wiring Diagrams Rating U.S./Canada International DPDT 2-Pole 2 Form C AgNi + Au Gold Plated Contacts 8 A DPDT 2-Pole 2 Form C AgNi Contacts Sockets 700-HN123 700-HN123 Coil Voltage Pkg. Qty. Cat. No. 6V AC 10 700-HPX2A06 12V AC 10 700-HPX2A12 24V AC 10 700-HPX2A24 120V AC 10 700-HPX2A1 240V AC 10 700-HPX2A2 6V DC 10 700-HPX2Z06 12V DC 10 700-HPX2Z12 24V DC 10 700-HPX2Z24 48V DC 10 700-HPX2Z48 110V DC 10 700-HPX2Z1 6V AC 10 700-HP32A06 12V AC 10 700-HP32A12 24V AC 10 700-HP32A24 120V AC 10 700-HP32A1 240V AC 10 700-HP32A2 6V DC 10 700-HP32Z06 12V DC 10 700-HP32Z12 24V DC 10 700-HP32Z24 48V DC 10 700-HP32Z48 110V DC 10 700-HP32Z1 64 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 700-HPS Safety Control Relay Photo Description Contact Wiring Diagrams Rating U.S./Canada International DPDT 2-Pole 2 Form C AgNi + Au Gold Plated Mechanically Linked Contacts 8 A DPDT 2-Pole 2 Form C AgNi Mechanically Linked Contacts 700-HPS DPDT Sockets 700-HN123 700-HN123 Accessories - 700-HP, -HPS Photo Description Diode Surge Suppressor Voltage Range: 6...220V DC used with 700-HN123 socket Diode with LED Surge Suppressor Voltage Range: 6...24V DC used with 700-HN123 socket Diode with LED Surge Suppressor Voltage Range: 28...60V DC used with 700-HN123 socket Diode with LED Surge Suppressor Voltage Range: 110...220V DC used with 700-HN123 socket Diode with LED Surge Suppressor Voltage Range: 6...24V AC used with 700-HN123 socket Varistor with LED Surge Suppressor Voltage Range: 110...240V AC used with 700-HN123 socket RC Surge Suppressor Voltage Range: 6...24V AC/DC used with 700-HN123 socket RC Surge Suppressor Voltage Range: 110...240V AC/DC used with 700-HN123 socket Timing Module On-Delay or One-Shot selectable voltage range: 12...24V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 110...125V AC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 230...240V AC used with sockets that accept plug-in accessory modules. Relay and Timer Specifications Coil Pkg. Voltage Qty. 6V DC 10 12V DC 10 24V DC 10 48V DC 10 60V DC 10 110V DC 10 125V DC 10 6V DC 10 12V DC 10 24V DC 10 48V DC 10 60V DC 10 110V DC 10 125V DC 10 Cat. No. 700-HPSXZ06 700-HPSXZ12 700-HPSXZ24 700-HPSXZ48 700-HPSXZ60 700-HPSXZ1 700-HPSXZ01 700-HPS2Z06 700-HPS2Z12 700-HPS2Z24 700-HPS2Z48 700-HPS2Z60 700-HPS2Z1 700-HPS2Z01 Pkg. Qty. Cat. No. 10 700-ADR 10 700-ADL1R 10 700-ADL2R 10 700-ADL3R 10 700-AV1R 10 700-AV3R 10 700-AR1 10 700-AR2 700-AT3 1 700-AT3A1 700-AT3A2 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 65 Relay and Timer Specifications Photo Description Pkg. Qty. Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting 8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation. 10 700-HN123 8-Way Jumper can be cut to required length. Rated 10 A 250V Plastic Retainer and Ejection Lever For use with the 700-HN123 sockets Built-in ability to accept 1492 snap-in markers Spring Clamp Terminal Socket -- Panel or DIN Rail Mounting 8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation. Plastic Retainer and Ejection Lever For use with the 700-HN230 sockets Built-in ability to accept 1492 snap-in markers Red Gray 1 Blue 700-TBJ20R 700-TBJ20G 700-TBJ20B 10 700-HN119 10 700-HN230 10 700-HN232 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 Relay Identification Snap-in Markers Note - These markers can only be used when the Plastic Retainer and Ejection Lever accessory (part # 700HN119) is used because the markers snap into the Ejection Lever (and not into the relay itself). 5 1492-MS5X12 5 1492-MS6X9 5 1492-MS6X12 5 1492-MS8X9 5 1492-MS8X12 100 1492-MP-Blank 700-N40 Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky 10 backing for easy placement on relays. 700-N41 Socket, and Retainer Clip Reference Relay Type Socket Cat. No. 700-HPX2 700-HN123 700-HP32 700-HN123 700-HPS2 700-HN123 700-HPSX 700-HN123 Retainer Clip Cat. No. 700-HN119 700-HN119 700-HN119 700-HN119 66 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications (1) - 700-HP Relays Cat. No. 700-HP... Contacts Inductive Resistive Minimum Load Nominal Coil Power (AC/DC) Operating Range (AC/DC) Holding Voltage (AC/DC) Must Drop Out Voltage (AC/DC) Insulation Voltage Design Specification/Test Requirements Dielectric Withstand Voltage for 1 minute Pole to Pole (VRMS) Contact to Coil (VRMS) Mechanical Degree of Protection Mechanical lifecycles Switching Frequency Operations Coil Voltages Operating Time at Nominal Voltage at 20 °C (ms) Pickup Dropout Maximum Operating Rate Vibration Enclosure Fragility Endurance Shock Fragility Max. Socket Torque Environmental Temperature Operating Storage Altitude Cat. No. 700-HP3..., 700-HPX Cat. No. 700-HPS... AC 15 @ 500V AC C300 B300 V AC 1/3 Hp @ 240V AC 1/2 Hp @ 240V AC 1/6 Hp @ 120V AC 1/3 Hp @ 120V AC AC-1 2000VA R300 -- DC-1: 8A @ 30V DC V DC DC-1: 0.3A @ 110V DC DC-1: 0.65A @ 110V DC DC-1: 0.1A @ 220V DC DC-1: 0.2A @ 220V DC AC 8 A @ 277V AC (per pole) DC 8 A @ 30V DC (per pole) 700-HP32: 300mW (5V, 5 mA) 700-HPX2: 50mW (5V, 5 mA) 700-HPS2: 500 mW (10V, 10 mA) 700-HPSX: 50 mW (5V, 5 mA) 1.2 VA / 0.65 W 0.7 W 80...110% / 73...150% Nominal Voltage 75...120% Nominal Voltage DC 80 / 40% Nominal Voltage 40% Nominal Voltage DC 20 / 10% Nominal Voltage 10% Nominal Voltage DC 250V AC 700-HP3, 700-HPX 700-HPS 2000V AC 4000V AC Open Type (Sockets) 10 x 106 (AC Coils), 20 x 106 (DC coils) 10 x 106 (DC Coils) 1800/hr (no load) 900/hr (no load) See Overview/Product Selection 12 10 4 16 Ops/s (full load) 8 Ops/s (full load) 5 G 2.5 G 50 G 15 G 0.5 N·m (4.4 lb·in) 40...+85 °C (40...+185 °F) 40...+70 °C (40...+158 °F) 45...+100 °C (49...+212 °F) 50...+80 °C (40...+176 °F) 2000 m (6560 ft) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 67 Relay and Timer Specifications Specifications (1) - 700-HP Relays Construction Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Approvals Certifications Standards (1) The inrush VA equals 1.5 times the sealed VA. Molded High-Dielectric Material Transparent Dust Cover Red Transparent Dust Cover Silver Nickel, (AgNi) (700-HP32 and 700-HPS2), Silver Nickel + Gold Plating (AgNi + Au) (700-HPX2 and 700-HPSX) In accordance with EN50 0005 2-Pole 700-HN123 cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN123 socket (File No. E3125, Guide NLDX/NLDC7), CSA Certified (files 229473), CE Marked, LR Certified (700-HP), IMQ & TÜV Certified (700- HPS) UL 508, CSA 22.2 No. 14, EN 61810-1, EN 50205 (700-HPS) 68 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700-HP Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 29.0 (1.14) 5.2 (13/64) Cat. No. 199-DR1 199-DR4 A 35 (1-3/8) 35 (1-3/8) 12.4 (0.49) 700-HP Relay 25.0 (0.98) 50 (1-63/64) 6.2 12.5 (15/64) (1/2) 1000 (39-3/8) Cat. No. 700-HN123 Single Wire: 0.2.....2.5 mm2 (#24.....14 AWG) Double Wire: 2 X 0.2.....2 X 2.5 mm2 (#2 X 24....2 X 14 AWG) Wire Type: solid or stranded, copper only Strip Length: 7 mm (9/32 in.), Torque: 0.5 N·m (4.4 lb·in) B C D 27 7.5 1.02 (1-1/16) (19/64) (1/64) 27 15 2.3 (1-1/16) (19/32) (3/32) 1.0 (0.04) 35.0 (1.38) 7.5 (0.3) 27.0 (1.06) Approx. Shipping Wt. 1.85 kg (4.07 lb) (10/pkg) 3.68 kg (8 lb) (5/pkg) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 69 Relay and Timer Specifications Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 60.9 (2.40) 21 6 11 3 17.5 (0.69) 17.5 (0.69) 24 14 5 4 22 12 7 2 21.6 (0.85) 78.6 (3.09) Ø 3.2 (0.12) Use M3 Screws 35.4 (1.39) 1 (-) 8 (+) A2 A1 4.0 (0.16) 15.8 (0.62) Cat. No. 700-HN123 Single Wire: 0.2.....2.5 mm2 (#24.....14 AWG) Double Wire: 2 X 0.2.....2 X 2.5 mm2 (#2 X 24....2 X 14 AWG) Wire Type: solid or stranded, copper only Strip Length: 7 mm (9/32 in.), Torque: 0.5 N·m (4.4 lb·in) 21.6 (0.85) Cat. No. 700-HN230 Min wire size: 0.5mm2 (21 AWG.) Max wire size: 2 x 1.5 and 1 x 2.5 mm2 (2 x18 / 1 x 14 AWG) Wire Type: solid or stranded, copper only Stripe Length: 8mm (10/32 in.) 70 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 700-HJ Magnetic Latching Relay · 10 A Contact Rating · SPDT · DPDT Single Coil · DPDT Dual Coil · Blade Style Quick Connect Terminals Photo Description Contact Wiring Diagrams Rating AC(2) DC(3) SPDT 1-Pole 1 Form C AgCdO Contacts (Single Coil 10 A AC or DC) Sockets 700-HN153 700-HN154 DPDT 2-Pole 2 Form C AgCdO Contacts (Single Coil 10 A AC or DC) Sockets 700-HN153 700-HN154 Relay and Timer Specifications Coil Voltage Cat. No. 24V AC 120V AC 700-HJ36A24 700-HJ36A1 24V DC 700-HJ36Z24 24V AC 120V AC 240V AC 700-HJ32A24 700-HJ32A1 700-HJ32A2 12V DC 700-HJ32Z12 24V DC 700-HJ32Z24 DPDT 2-Pole 2 Form C AgCdO Contacts (Dual Coil(1) 10 A DC Only 24V DC 700-HJD32Z24 Sockets (1) Available only in DC Coil with DPDT contacts. (2) AC Relays include internal diodes. (3) For DC operation, polarity must be observed. 700-HN153 or 700-HN154 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 71 Relay and Timer Specifications Accessories-700-HJ Relays Photo Description Pkg. Qty. Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting. Guarded Terminal Construction 11-blade socket for use with 700-HB relays. This socket has coil and contact separation as well as the 10 ability to use optional plug-in modules ( 700-A__ accessories, LED, surge suppression, timing modules). 700-HN153 Screw Terminal Base Socket -- Panel or DIN Rail Mounting. Open Style Construction 11-blade for use with 700-HB relays. 10 700-HN154 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 Retainer Clip For Cat. Nos. 700-HN153 and -HN154 Sockets with 700-HJ Relays 10 Secures relay in socket. Order must be for 10 clips or multiples of 10. Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are 10 peel-off with sticky backing for easy placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10 relays. Socket and Retainer Clip Reference Relay Type 700-HJ Socket Cat. No. 700-HN153 700-HN154 Retainer Clip Cat. No. 700-HN159 700-HN159 700-HN159 700-N40 700-N41 Specifications - 700-HJ Relays Attribute Pilot Duty Rating Rated Thermal Current (Ith) Rated Insulation Voltage(Ui) Contacts Permissible Coil Voltage Variation Inductive 120V AC 240V AC DC 700-HJ Electrical Ratings -- 10 A 250V IEC, 300V UL/CSA Make Break Hp 30 A 3 A 1/4 15 A 1.5 A 1/3 24V DC, 10 A 85...110% of Nominal Voltage at 50 Hz 85...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC 72 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-HJ Relays Coil Consumption ±10% AC Coils DC Coils Dielectric Withstand Voltage Degree of Protection Mechanical Life Operations Switching Frequency Operations Coil Voltages Operating Time at Nominal Voltage at 20 °C Maximum Operating Rate Temperature Altitude Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Standards Single AC Coil Single DC Coil Dual DC Coil Inrush Sealed 1.44 VA 1.44 VA -- -- -- 1.2 W 12V 1.63 W 24V 1.67 W Design Specification/Test Requirements Pole-to-Pole 1500V AC Contact-to-Pole 1500V AC Contact-to-Frame 1500V AC Mechanical Open Type (Guarded Terminal Sockets) 10 x 106 1800/HR See Product Selection Pickup 25 ms Dropout 25 ms -- Environmental Operating 45...+50 °C (49...+122 °F) Storage 45...+100 °C (49...+212 °F) 2000 m (6560 ft) Construction Molded High Dielectric Material Transparent Dust Cover Silver Cad. Ox. In accordance with EN50 0005 11-Blade Socket Cat. No. 700-HN153 Cat. No. 700-HN154 CSA Certified, File LR700026, UL Recognized, File E3125, Guide NLDX 2 UL 508, CSA 22.2 No. 14, EN/IEC 60947-4-1, -5-1 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 73 Relay and Timer Specifications Dimensions - 700-HJ Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 700-HJ Relay Cat. No. 700-HN153 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (#214 AWG... #220 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) Torque: 0.8 N·m (7 lb·in Cat. No. 700-HN154 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (#214 AWG... #220 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) Torque: 0.8 N·m (7 lb·in) 5.2 (13/64) 50 (1-63/64) 6.2 12.5 (15/64) (1/2) 1.0 (0.04) 35.0 (1.38) 27.0 (1.06) 1000 7.5 (39-3/8) (0.3) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes Cat. No. 199-DR1 199-DR4 A 35 (1-3/8) 35 (1-3/8) B 27 (1-1/16) 27 (1-1/16) C 7.5 (19/64) 15 (19/32) D 1.02 (1/64) 2.3 (3/32) Approx. Shipping Wt. 1.85 kg (4.07 lb) (10/pkg) 3.68 kg (8 lb) (5/pkg) 74 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-HG Power Relay · 40 A Contact Ratings · SPST-NO-DM, SPDT, DPST-NO, DPDT · Panel Mounted · Options: Magnetic Blowout for High DC Loads, Auxiliary Snap Action Switch · Screw Terminals #6-32 for Coil, #8-32 for Contacts Description Contact Ratings Wiring Diagrams SPST-NO-DM 1 Form X AgCdO Contacts 40 A (A600) SPDT 1-pole 1 Form C AgCdO Contacts 40 A (A600) DPST-NO 2-pole 2 Form A AgCdO Contacts 40 A (A600) DPDT 2-pole 2 Form C AgCdO Contacts 40 A (A600) (1) Auxiliary Snap Switch Option: Add suffix (-5) to the selected 700-HG relay Cat. No., except for the 220V DC add (-5L). Magnetic Blowout Option: Add suffix (-6) to the selected 700-HG relay Cat. No. (suppresses the arc when switching DC loads ratings listed below). Coil Voltage 24V AC 120V AC 240V AC 277V AC 480V AC 12V DC 24V DC 48V DC 110V DC 24V AC 120V AC 240V AC 12V DC 24V DC 48V DC 110V DC 24V AC 120V AC 240V AC 480V AC 12V DC 24V DC 48V DC 110V DC 24V AC 120V AC 240V AC 277 AC 12V DC 24V DC 48V DC 110V DC 220V DC 250V DC Cat. No.(1) 700-HG45A24 700-HG45A1 700-HG45A2 700-HG45A27 700-HG45A4 700-HG45Z12 700-HG45Z24 700-HG45Z48 700-HG45Z1 700-HG46A24 700-HG46A1 700-HG46A2 700-HG46Z12 700-HG46Z24 700-HG46Z48 700-HG46Z1 700-HG47A24 700-HG47A1 700-HG47A2 700-HG47A4 700-HG47Z12 700-HG47Z24 700-HG47Z48 700-HG47Z1 700-HG42A24 700-HG42A1 700-HG42A2 700-HG42A27 700-HG42Z12 700-HG42Z24 700-HG42Z48 700-HG42Z1 700-HG42Z2 700-HG42Z25 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 75 Relay and Timer Specifications Accessories - 700-HG Relays Photo Description Pkg. Qty. Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. 10 Tags are peel-off with sticky backing for easy placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10 easy placement on relays. Cat. No. 700-N40 700-N41 Type 1 Enclosure For use with any of the listed relays. Knockouts for 1/2 in. and 3/4 in. conduit connections. The enclosure exceeds the minimum clearances required by U.S. standards, resulting 1 in generous wiring spaces. 700-HN120 Auxiliary Snap Action Switch Contact SPDT (1 Form C) Material Silver Cad. Ox. Rating 10 A at 120 or 240 Resistive Dielectric Withstand V (1 Min.) 1500V AC RMS Contact to Frame 76 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-HG Relays Attribute Electrical Ratings Pilot Duty Rating (1) Rated Thermal Current (Ith) Rated Insulation Voltage(Ui) Contact Ratings: AC Ratings SPST-NO-DM 700-HG A600 40 A 600V UL Contact Ratings: AC Ratings SPDT, DPST - NO and DPDT Inductive Resistive - Inductive Resistive - Volts Make Break Make/Break Continuous and Continuous HP Volts Make Break Make/Break Continuous and Continuous HP (2) 120 60 A 6 A 10 A 40 A 120 60 A 6 A 10 A 40 A 2 1 - 1/2 240 30 A 3 A 10 A 40 A 240 30 A 3 A 10 A 40 A 480V 15 A 1.5 A 10 A 12 A 480 15 A 1.5 A 10 A 5 A 2 1 - 1/2 600V 12 A 1.2 A 10 A 10 A 600 15 A 1.2 A 10 A 5 A DC Ratings: Without Magnetic Blowouts - 28V 40 A - Make, Break and Continuous Est Drop 125V 1.2...3 A DC Ratings: With Magnetic Blowouts: SPST - NO DM SPDT, DPST - NO and DPDT 110V 20 A 10 A 220V 8 A 4 A Make, Break, and Continuous 325V 4 A 2 A 500V 2 A -- 80...100% of Nominal Voltage at 50 Hz Permissible Coil Voltage Variation 85...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC 50 HZ 60 HZ Inrush 13 VA 16 VA AC Coils Coil Consumption ±10% Sealed 10 VA 11 VA DC Coils 2.0 W Design Specification/Test Requirements Dielectric Withstand Voltage Pole-to-Pole Contact to Pole Contact to Frame 2200V AC 2200V 2200V AC Mechanical Degree of Protection Mechanical Life Operations Open Type 5 x 106 Switching Frequency Operations 1600/Hr Coil Voltage See Overview/Product Selection Operating Time at Nominal Pickup 40 ms Voltage at 20 °C (68 °F) Dropout 35 ms Maximum Operating Rate -- Rockwell Automation Publication 700-TD552F-EN-P - January 2021 77 Relay and Timer Specifications Specifications - 700-HG Relays Temperature Altitude Operating Storage Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Standards (1) See NEMA Ratings and Test Values on page 5. (2) For DPDT only: 2 Hp Switching 2 Poles, 200...600V AV, 50/60 Hz. Environmental 30...+55 °C (-22...+149 °F) -30...+65 °C (-22...+149 °F) 2000 m (6560 ft) Construction Molded Thermo Setting Plastic -- Silver Cadmium Oxide -- -- CSA Certified, File 225674, UL Listed, File E3125, Guide NLDX, CE Marked UL 508, CSA 22.2 No. 14, EN/IEC 60947-1, -5-1 78 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700-HG Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 700-HG Relay, SPST-NO-DM 700-HG Relay Rockwell Automation Publication 700-TD552F-EN-P - January 2021 79 Relay and Timer Specifications 700-HHF Flange Mount Power Relay · Flange-Mounted · Blade Style 0.250 x 0.032 Quick Connect/Solder (no socket) Terminals · Solder Terminals (no socket) Description Contact Rating Wiring Diagrams U.S./Canada International SPST-NO-DM 1 Form X AgCdO Contacts 30 A (A600) Coil Voltage 120V AC Cat. No. 700-HHF45A1 24V DC 700-HHF45Z24 DPDT 2-Pole 2 Form C AgCdO Contacts 25 A (B600) 24V AC 120V AC 240V AC 12V DC 24V DC 700-HHF62A24 700-HHF62A1 700-HHF62A2 700-HHF62Z12 700-HHF62Z24 3PDT 3-Pole 3 Form C AgCdO Contacts 20 A (B300) 120V AC 700-HHF73A1 Specifications - 700-HHF Relays Attribute Electrical Ratings Pilot Duty Rating (1) Rated Thermal Current (Ith) Rated Insulation Voltage(Ui) Inductive Contacts 120V AC 240V AC DC 700-HHF... SPST-NO-DM NEMA A600 DPDT NEMA B600 3PDT NEMA B300 SPST-NO-DM 30 A, DPDT 25A, 3PDT 20 A 250V IEC-300V UL/CSA SPST-NO-DM Hp DPDT Hp 3PDT Hp 60 A 6 A 1 30 A 3 A 1 30 A 3 A 1/2 30 A 3.0 A 1-1/2 15 A 1.5 A 1-1/2 15 A 1.5 A -- 28V DC, 30 A 28V DC, 13 A -- 80 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-HHF Relays Attribute 700-HHF... 85...110% of Nominal Voltage at 50 Hz Permissible Coil Voltage Variation 85...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC SPST-NO-DM DPDT 3PDT 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz Coil Consumption ±10% AC Coils DC Coils Inrush Sealed 7.2 VA 6.3 VA 7.2 VA 6.3 VA 7.2 VA 4.8 VA 4.2 VA 4.8 VA 4.2 VA 4.8 VA 1.4 W Max. Allowable Leakage 25% of VA 10% of W Design Specification/Test Requirements Dielectric Withstand Voltage Pole-to-Pole Contact-to-Pole Contact-to-Frame 2200V AC 2200V AC 1600V AC Mechanical Mechanical Life Operations 5 x 106 Switching Frequency Operations 3600/Hr Coil Voltages See Overview/Product Selection Operating Time at Nominal Pickup 20 ms Voltage at 20 °C Dropout 15 ms Maximum Operating Rate 4 Ops/s. Environmental Temperature Operating Storage 30...+50 °C (22...+122 °F) 30...+100 °C (22...+212 °F) Altitude 2000 m (6560 ft) Construction Insulating Material Molded High Dielectric Material Enclosure Transparent Dust Cover Contact Material Silver Cadmium Oxide Terminal Markings Sockets In accordance with EN50 0005 (2) Certifications cURus Recognized, File E3125,Guide NLDX2/NLDX8, CE Marked Standards UL 508, CSA 22.2 No.14, EN/IEC 60947-1, -5-1 (1) See NEMA Ratings and Test Values on page 5. (2) 700-HHF relay wiring and terminals are the quick connect / solder type 6.35 x 0.82 mm (0.250 x 0.032 in) termination. 60 Hz 6.3 VA 4.2 VA Rockwell Automation Publication 700-TD552F-EN-P - January 2021 81 Relay and Timer Specifications Dimensions - 700-HHF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 35.7 (1-13/32) 3.97 (5/32) 38.9 (1-17/32) 700-HHF Relay 63.5 (2-1/2) 73.8 (2-29/32) 82 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-HTA Alternating Relay · Alternating Relay · Rugged Pin Style Socket Mounting · 10 A, SPDT, DPDT, and Cross Wired · Excellent for Pump Panel Applications 700 HTA 2 A12 7 a b c d e Catalog Number Explanation - 700-HTA Relays a Bulletin Number - b Relay Type c Model Type 1 - SPDT 700 HTA - Tube Base Alternating Relay 2 - DPDT 3 -Cross-Wired Alternating Relays with Pin-Style Terminations 700-HTA Alternating Relay Wiring Diagrams U.S./Canada d Coil Voltage A12 - 12V AC 50/60 Hz A24 - 24V AC 50/60 Hz A1 - 120V AC 50/60 Hz A2 - 240V AC 50/60 Hz e Gold Plated Contacts Option Blank - Without switch 7 - With switch International SPDT Form C Contact SPDT DPDT 2 Form C Contact DPDT Cross-Wired DPDT 2 Form C Contacts Cross-Wired Rockwell Automation Publication 700-TD552F-EN-P - January 2021 83 Relay and Timer Specifications Accessories - 700-HTA Relays Photo Description Pkg. Qty. Cat. No. Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with 700-HTA1A or -HTA3A alternating relays. Order ten or multiples of ten. 10 700-HN100 Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use with 700-HTA1A or -HTA3A alternating relays. Order ten or multiples of ten. No retainer clip required. 10 700-HN125 Screw Terminal Tube Base Sockets -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 11pin for use with 700-HTA2A alternating relays. Order in multiples of 10. 10 700-HN101 Screw Terminal Tube Base Sockets -- Panel or DIN Rail Mounting; Open Style Terminal Construction. 11-pin for use with 700-HTA2A alternating relays. Order in multiples of 10. No retainer clip required. 10 700-HN126 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with 700-HT Timing Relays, and 700-HTA Alternating Relays 10 Secures relay in socket. Order must be for 10 clips or multiples of 10. 700-HN110 Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10 easy placement on relays. 700-N40 Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N41 84 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-HTA Relays Attribute Pilot Duty Rating (1) Rated Thermal Current (Ith) Rated Insulation Voltage(Ui) Electrical Ratings Inductive Make 700-HTA NEMA B300 AC 15 10 A 250V IEC, 300V UL/CSA Break HP Contacts 120V AC 30 A 3 A 1/3 240V AC 15 A 1.5 A 1/2 Resistive 30V DC 10 A 10 A -- Permissible Coil Voltage Variation 85...110% of Nominal Voltage at 50 Hz 85...110% of Nominal Voltage at 60 Hz 24V AC 2 VA Power Consumption ±10% AC 120V AC 4 VA 240V AC 4 VA Design Specification/Test Requirements Pole-to-Pole, same circuit (VRMS) 1000V AC Dielectric Withstand Voltage Pole-to-Pole, different circuits (VRMS) 2000V AC Contact-to-Coil (VRMS) 2000V AC Electrical Life Operations 100,000 minimum Switching Frequency Operations 1800/hr Coil Voltages See product selection Mechanical Degree of Protection Mechanical Life Operations Open Type (Guarded Terminal Sockets) 10 x 106 Switching Frequency Operations 18,000/hr Start-up Time (max. time from power application until unit is timing) 0.05 sec Max. Function Time (max. time power can drop out and unit continues timing) 0.01 sec Min. Cycle Time 100 ms on release of the control switch Rockwell Automation Publication 700-TD552F-EN-P - January 2021 85 Relay and Timer Specifications Specifications - 700-HTA Relays Attribute Temperature Altitude Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Certifications Standards (1) See NEMA Ratings and Test Values on page 5. Operating Storage 700-HTA Environmental 28...+65 °C (50 °C max., 240V AC coil) (18...+149 °F) (122 °F max., 240V AC coil) 55...+85 °C (67...+185 °F) 2000 m (6560 ft) Construction Molded High Dielectric Material Impact Resistant Dust Cover Silver Tin Oxide In accordance with EN50 005 8- or 11-Pin Socket 700-HN100, -HN125 700-HN101, -HN126 CSA Certified, File 223833, UL Recognized (File E3125 Guide NLDX2/NLDX8), cULus Listed with 700-HN100, 700-HN101, 700-HN125, and 700-HN126 Sockets (File No. E3125 Guide NLDX/NLDX7), CE-Marked (per EU Low Voltage Directive) EN 61812-1, CSA 22.2 No. 14, UL 508 86 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Trigger Signal Cat. Nos. 700-HTA Contact closure provides signal to timer. The 700-HTA alternating relay generates a low energy signal. For optimum reliability, use contacts designed for low energy switching (10V, 1 mA) (Example: Bul. 800F-X_V, 800T-X_V). No external voltage can be connected to the contact signal. Load Diagrams - 700-HTA Relays Common Input/Output SPDT/DPDT B1 Load A Load B LED A LED B Power Socket Pinout Map SPDT Relay Socket A1 4 A2 3 Socket Pinout Map DPDT Relay Socket A1 4 A2 8 Note: pin out in wiring diagram may not match actual printed socket see pinout map for wiring up the power source Cross Wired Lead/Lag/Lag/lead Sequence Lead Lag Load A Load B LED A LED B Power Socket Pinout Map Cross-Wired Relay Socket A1 3 A2 6 Note: pin out in wiring diagram may not match actual printed socket see pinout map for wiring up the power source Rockwell Automation Publication 700-TD552F-EN-P - January 2021 87 Relay and Timer Specifications Dimensions - 700-HTA Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 74 (2-29/32) 79 (3-7/64) 60 (2-23/64) 43 (1-11/16) 30.0 (1-3/16) 65.0 (2-35/64) 26 (1-1/32) 38.0 (1-1/2) #440 M3 Cat. No. 700-HN100 Panel Mounting Double Wire -- 2 x 2.5 mm2 (#2 14 AWG...#2 20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) Torque: 0.8 N·m (7 lb·in) 40.1 (1-37/64) 24.6 (31/32) 20.8 (53/64) 24.9 (63/64) 4.2 (5/32) 54.9 (2-5/32) 51.1 (2-1/64) 33.0 (1-19/64) 14.7 (37/64) Cat. No. 700-HN125 Wire Size: 2 x 2.5 mm2 Single Wire -- Up to #12 AWG Double Wire -- 2 x 2.5 mm2 (#2 14 AWG... #2 20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) -- Torque: 0.8 N·m (7 lb·in) 65.0 (2-35/64) 30 (1-3/16) 26 (1-1/32) 38.0 (1-1/2) #4-40 M3 Cat. No. 700-HN101 Panel Mounting Double Wire 2 x 2.5 mm2 (#2 14 AWG...#2 20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) Torque: 0.8 N·m (7 lb·in) 59.2 (2-1/3) 7.9 (0.31) 26.9 (1.06) 24.6 (31/32) 20.8 (53/64) 54.9 (2-5/32) 4.2 (5/32) 51.1 (2-1/64) 52.3 (2.06) Cat. No. 700-HN126 Wire Size: 2 x 2.5 mm2 Single Wire -- Up to 12 AWG Double Wire -- 2 x 2.5 mm2 (#2 14 AWG...#2 20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) -- Torque: 0.8 N·m (7 lb·in) 88 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 General Purpose Electronic Timers and Counters Product Overview Relay and Timer Specifications Bulletin No. Type Features Control Outputs: Time Limit Instantaneous Operation Modes: Time Range Supply Voltage Contact Rating at 120V AC Certifications Socket Cat. No(s). Page 700-FE DIN Rail Timer · Only 17.5 mm wide · 5 A contact rating · Multifunction or single function · No additional socket required 1 N.O. or SPDT timed On-delay Off-delay One shot Repeat cycle-pulse Fleeting off-delay Pulse converter 0.05 s...10 hr 24V AC/DC 110...240V AC 24...48V AC/DC 24...240V AC 5 A CE, cULus DIN Rail or panel mount 92 700-FS DIN Rail Timer · Only 22.5 mm wide · 8 A contact rating · Multifunction or single function · No additional socket required · Optional: · Star-delta timing function · True off-delay timing function · Hazardous location certification SPDT or DPDT or 2 N.O. + 1 common 11 timing modes 0.05 s...60 hr 12V DC 24V...48V DC 24V...240V AC 8 A CE, cULus DIN Rail or panel mount 96 700-HR52, -HRP, -HRS, -HRT, -HRV 700-HRM/-HRC 700-HRF Multifunction Timer On-Delay Timer Twin Timer · Dial timing relays · 5 A contact rating · Multiple programmable timing ranges · Tube base pin style terminals · Multi-voltage inputs · Timed contacts and instantaneous contacts · Transistor outputs · Single function and multi-function · 7 different operating modes · Dial timing relays · 5 A contact rating · Multiple programmable timing ranges · Tube base pin-style terminals · Multi-voltage inputs · Timed contacts and instantaneous contacts · Transistor outputs · Single function and multi-function · Independent ON and OFF settings · 14 time ranges · 8-pin models available · Dial timing relays · UL508 DPDT Timed, Transistor SPDT Timed/Instantaneous DPDT Timed, Transistor SPDT Timed/Instantaneous DPDT Timed On-Delay Off-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start Signal On/Off-Delay On-Delay One Shot 0.05 s...300 h 12...48V DC 24...48V AC 100...240V AC 100...125V DC On-Delay 0.05 s...300 h 12...48V DC 24...48V AC 100...240V AC 100...125V DC Repeat Cycle Off Start Repeat Cycle On Start 0.05 s...300 h 12V DC 24V AC/DC 48...125V DC 100...240V AC 5 A 5 A 5 A cURus, CE, C-Tick cURus, CE, C-Tick 700-HN100 OR 700-HN101 700-HN100 700-HN125 OR 700-HN126 700-HN125 116 117 cURus, CE, C-Tick 700-HN100 700-HN125 117 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 89 Relay and Timer Specifications Bulletin No. Type 700-HRY Star-Delta Timer 700-HRQ True Off-Delay Timer Features · A wide star-time range (up to 120 s) · Star-delta transfer time range (up to 0.5 s) · UL Recognized · Dial timing relays · Long power Off-delay times · 11-pin and 8-pin models are available · UL Recognized Control Outputs: Time Limit Instantaneous SPST (Star, Delta) Timed SPST - NO Instantaneous Operation Modes: Star-Delta Time Range 0.5 s...120 s Supply Voltage 100...120V AC 200...240V AC Contact Rating at 120V AC Certifications Socket Cat. No(s). Page 5 A cURus, CE, C-Tick 700-HN100 700-HN125 117 DPDT Timed True OFF-delay Timer True OFF-delay Timer w/reset 0.05 s...12 min 48V DC 24V AC/DC 100...240V AC 100...125V DC 5 A cURus, CE, C-Tick 700-HN100 OR 700-HN101 700-HN125 OR 700-HN126 118 700-HNC 700-HNK Miniature Timer Ultra-Slim Timer · Four different operating modes · DIN Rail mount with socket · Pin configuration same as 700-HC relay · Ultra-slim timing relay · Four different operating modes · Three operating voltages · DIN Rail mount with socket · Pin configuration same as 700-HK relay 4PDT SPDT, DPST-NO On-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start 0.1 s...10 h 12V DC 24V AC/DC 48...125V DC 100...240V AC 5 A cURus, CSA, CE, C-Tick 700-HN103 700-HN128 103 On-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start 0.1 s...10 h 12V DC 24V DC 24V AC 5 A cURus, CE, ACA 700-HN121 700-HN122 109 90 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Bulletin No. Type 700-HT Tube Base Timing Relay 700-HV Repeat-Cycle Timing Relay Features · Pin-style terminals · Single range or fixed timers · Available as ON- or OFF-Delays · Pin-style terminals · Single-range timer · Repeat cycle Control Outputs: Time Limit Instantaneous DPDT DPDT Timing Operation Modes: On-Delay Off-Delay Repeat Cycle Time Range Supply Voltage Contact Rating at 120V AC Certifications Socket Cat. No(s). Page 0.1 s...30 min. 12V DC 24V DC 24V AC 120V AC 240V AC 10 A UR, UL, CSA, CE 700-HN100 OR 700-HN101 700-HN125 OR 700-HN126 128 0.1 s...30 min. 24V DC 24V AC 120V AC 240V AC 10 A UR, UL, CSA, CE 700-HN100 700-HN125 133 700-HX Digital Timer · Digital timer · 5 A contact rating · Negative transmissive LCD display · 10 functions or modes · Environmentally friendly--flash memory, no battery · NEMA B300 rated · NEMA 4/IP66 · DIN Rail or panel mount capable SPDT Signal On-Delay 1 and 2 Signal Off-Delay One Shot Repeat Cycle Off Start Repeat Cycle On Start Signal On/Off-Delay Power On-Delay 1 and 2 Twin Timer Cumulative 0.05 s...300 h 12...24V DC 24V AC 100...240V AC 5 A cURus, CE, C-Tick 700-HN100 700-HN125 138 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 91 Relay and Timer Specifications 700-FE Economy Timing Relay · Adjustable function and timing range timing relays · DIN Rail mounted without cost of socket · 17.5 mm wide, multi-function or single function · Available as 1 N.O. or SPDT contact output, 5 A · Timing ranges from 0.05 s...10.0 hr · Coil surge protection Multi-Function This device offers you the flexibility of selecting one of 4 single timing functions. Operating Mode Contact Output Timing Range(1) ON-delay, OFF-delay, One Shot, Flasher (repeat cycle starting with pulse) 1 N.O. 0.05 s...10 hr (6 settings) ON-delay, OFF-delay, One Shot, Flasher (repeat cycle starting with pulse) SPDT (1 C/O) (1) Time ranges: 0.05 s...1 s, 0.5...10 s, 0.05...1 min, 0.5...10 min, 0.05...1 hr, 0.5...10 hr. (2) Voltage is either 24V AC/DC 50/60 Hz. 0.05 s...10 hr (6 settings) Input Voltage 24V AC/DC (2) 110...240V AC 50/60 Hz 24V...48V AC/DC 24...240V AC 50/60 Hz Cat. No. 700-FEM1TU22 700-FEM3TU23 Single-Function This device offers you one specific timing function. Operating Mode Contact Output Timing Range(1) ON-delay 1 N.O. SPDT (1 C/O) 0.05 s...10 hr (6 settings) 0.05 s...10 hr (6 settings) OFF-delay 1 N.O. SPDT (1 C/O) 0.05 s...10 hr (6 settings) 0.05 s...10 hr (6 settings) One Shot 1 N.O. SPDT (1 C/O) 0.05 s...10 hr (6 settings) 0.05 s...10 hr (6 settings) Fleeting OFF-delay SPDT (1 C/O) 0.05 s...10 hr (6 settings) Flasher (repeat cycle starting with pulse) 1 N.O. SPDT (1 C/O) 0.05 s...10 hr (6 settings) 0.05 s...10 hr (6 settings) Pulse Converter SPDT (1 C/O) 0.05 s...10 hr (6 settings) (1) Time ranges: 0.05 s...1 s, 0.5...10 s, 0.05...1 min, 0.5...10 min, 0.05...1 hr, 0.5...10 hr. (2) Voltage is either 24V AC 50/60 Hz or 24V DC. Input Voltage 24V AC/DC 110...240V AC 50/60 Hz(2) 24V...48V AC/DC 24...240V AC 50/60 Hz 24V AC/DC 110...240V AC 50/60 Hz(2) 24V...48V AC/DC 24...240V AC 50/60 Hz 24V AC/DC 110...240V AC 50/60 Hz(2) 24V...48V AC/DC 24...240V AC 50/60 Hz 24V...48V AC/DC 24...240V AC 50/60 Hz 24V AC/DC 110...240V AC 50/60 Hz(2) 24V...48V AC/DC 24...240V AC 50/60 Hz 24V...48V AC/DC 24...240V AC 50/60 Hz Cat. No. 700-FEA1TU22 700-FEA3TU23 700-FEB1TU22 700-FEB3TU23 700-FED1TU22 700-FED3TU23 700-FEE3TU23 700-FEF1TU22 700-FEF3TU23 700-FEL3TU23 Special Functions Operating Mode Star-Delta Contact Output 2 N.O. with 1 Common Timing Range(1) 0.15 s...10 min (4 settings) Input Voltage 24V...48V AC/DC 24...240V AC 50/60 Hz (1) Time ranges: 0.15...3 s, 0.5...10 s, 3 s...1 min, 30 s...10 min. 92 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Cat. No. 700-FEY2QU23 Relay and Timer Specifications Accessories - 700-FE Relays Description Pkg. Quantity Cat. No. Panel Mounting Adapter For surface mounting according to drilling plan EN 50 002 5 199-FSA Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm Function and Connection Diagrams - 700-FE Relays 10 100-FMS (A) On-Delay U Output t LED A1/A2 18 15 A1/A3 15 A2 18 1 N.O. (SPST) U Output t LED (D) One Shot A1/A2 151186 A1 15 A2 18 16 1 C/O (SPDT) (B) Off-Delay U S Output t LED A1/A2 A1/B1 18 15 1 N.O. (SPST) A1 B1 S 15 A2 18 U S Output t LED A1/A2 A1/B1 18 15 16 A1 B1 S 15 A2 18 16 1 C/O (SPDT) (F) Flasher (Repeat Cycle Starting with Pulse) U Output t LED A1/A2 1518 A1 15 A2 18 1 N.O. (SPST) U Output LED A1/A2 t t t t 18 t 15 A1 15 A2 18 1 N.O. (SPST) U Output t LED A1/A2 151186 A1 15 A2 18 16 1 C/O (SPDT) (E) Fleeting Off-Delay U Output LED t tt A1/A2 t t 18 1516 A1 15 A2 18 16 1 C/O (SPDT) (L) Pulse Converter A1/A2 B1 t LED 1 C/O (SPDT) (Y) Star-Delta Timing Relay 1) S A1 B1 15 A2 18 16 U S Output t LED A1/A2 A1/B1 t 151186 1) S A1 B1 15 A2 18 16 U A1/A2 t 17/18 17/28 tu = 50...65 ms LED A1 17 A2 18 28 Bi-color light-emitting diode: 1 C/O (SPDT) or 1 N.O. Contact Timers Single Color light-emitting diode: 2 N.O. with Common LED U = green: Supply voltage available. LED Relay = red: Output is energized. ON = green OFF = red Rockwell Automation Publication 700-TD552F-EN-P - January 2021 93 Relay and Timer Specifications Specifications - 700-FE Relays(1) Attribute 700-FE 1 N.O. SPDT Setting Accuracy Repeatability Tolerance Supply Voltage AC Voltage Tolerance DC Power Consumption Time Energized Reset Time Cable Length (Supply Voltage Control) Impulse Duration Input Voltage Input Current Cable Length Contact Type Dielectric Withstand Voltage Contact-to-coil Power Switching Capacity According to IEC 9475-1 According to UL 508 Short circuit Resistance Mechanical Life Electrical State Indicator Certifications Standards Insulation Characteristics EMC/Interference Immunity EMC / Emission (1) Time Characteristics (according to VDE 0435, part 2021) ±5% of full scale ±1% of setting (typical) By voltage: ±0.01%/%U By temperature: ±0.25%/°C By voltage: ±0.001%/%U By temperature: ±0.025%/°C Supply 24V AC/DC(1) and 110...240V AC, 50/60 Hz 24...48V DC and 24...240V AC, 50/60 Hz 15%/+10% 15%/+20% 0.5 W at 24V DC, 5VA at 240V AC 100% 100 ms Max. 250 m (750 feet) Pulse Control (B1) 250 ms 50 ms (AC), 30 ms (DC) supply voltage range 1 mA Max. 250 m without parallel load between B1 and A2 Max. 50 m with load (< 3 k between B1 and A2 Outputs 1 N.O. contact 1 Form C SPDT contact 4000V 1250VA AC-1 5 A /250V AC (resistive load) AC-14 1 A/250V AC (inductive load) DC-13 1 A/24V DC (inductive load) NEMA D300 - 1 A/300V AC 6 A gL (Fast Blow Fuse) 20 million operations 0.4 million at 1 A/250V AC, resistive 0.4 million at 0.5 A/250V AC, cos = 0.4 0.4 million at 1 A/24V DC, resistive 1 bicolor light-emitting diode (Supply; Relay) cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14 2 kV AC/50 Hz test voltage according to VDE 0435 and 4 kV 1.2/50 s surge voltage according to IEC 60947-1 between all inputs and outputs The following requirements are fulfilled: Surge capacity of the supply voltage according to IEC 61000-4-5: Level 3 Burst according to IEC 61000-4-4: Level 3 ESD discharge according to IEC 61000-4-2: Level 3 electromagnetic fields according to EN 55 022: Class B 94 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Attribute Safe Isolation Climatic Withstand Vibration Resistance Shock Resistance Protection Class IEC 60947-1 Weight Certifications Ambient Temperature Connections Mounting Disposal (1) Voltage is either 24V DC or AC 50/60 Hz. 700-FE according to VDE 0106 T 101 56 cycles (24 hr) at 25...40 °C and 95% relative humidity according to IEC 60068-2-30 4 g in three axes at 10...500 Hz, test FC according to IEC 60068-2-6 50 g according to IEC 68-2-27 Enclosure: IP40 Terminal: IP 20 60 g 60 g cULus, CE Certified cULus, Germanischer Lloyd, CE Certified Open: 25...+60 °C Enclosed: 25...+45 °C Storage: 40...+85 °C Screw terminal M3 for Pozidriv No.1, Philips, and slotted screws No.2. suitable for power screwdriver. Rated tightening torque 8.8 lb.-in. (max. 1.0 Nm) For terminal cross-sections of 1 x 0.5 mm2...2 x 1.5 mm2 (solid) or 2 x 1.5 mm2 (stranded with sleeve), #20...14 AWG. Finger protection according to EN 50274 For surface mounting in any position; snap-on mounting on 35 mm DIN Rail or by adapter and two screws (M4 type) Synthetic materials without dioxin according to EC/EFTA-Notification No. 93/0141/D electrical contacts are AgCdO Dimensions - 700-FE Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 80.0 (3-5/32) 43.0 (1-11/16) 45.0 (1-25/32) 17.5 (11/16) 66.0 (2-9/16) 70.0 (2-49/64) Cat. No. 700-FE... 22.5 (0.89) 13 (0.51) 4.3 (0.17) 75.0 (2.95) 35.0 (1.38)58.0 (2.28) 4.3 (0.17) 9.0 (0.35) 17 12 (0.67) (0.47) 2.0 (0.08) 5.5 (0.22) Cat. No. 199-FSA... Rockwell Automation Publication 700-TD552F-EN-P - January 2021 95 Relay and Timer Specifications 700-FS High Performance Timing Relay · Adjustable function and timing range timing relays · DIN Rail mounted without cost of socket · 22.5 mm wide multi-function or single functions · Available as SPDT or DPDT contact output, 8 A · Timing Ranges From 0.05 s...60 hr · Coil surge protection · Hazardous location version available Catalog Number Explanation - 700-FS Relays 700 FS H a b c 3 U U23 d e f a b Bulletin - Type of Number Relay c Operating Mode AOn-delay BOff-delay COn- and off-delay DOne shot EFleeting off-delay 700 FS FFlasher (repeat cycle starts with pulse) GFlasher (repeat cycle starts with pause) IOn-delay pulse generator JOn-delay (pulse controlled) KOne shot/watch dog (pulse controlled) LPulse converter d Contact Output e Timing Range f Input Voltage 3One changeover contact (SPDT)1 C/O A0.05...1 s B0.15...3 s C0.5...10 s D1.5...30 s E0.05...1 min F0.15...3 min G0.5...10 min H1.5...30 min I0.05...1 hr J0.15...3 hr K0.5...10 hr L3.0...60 hr U0.05 s...60 hr (1) Z1212V DC U2324...48V DC | 24...240V AC 50/60 Hz (1) Valid for functions "A" and "B" only. Single Function (With 2PDT 2 C/O contacts) Operating Mode On-delay Contact Output (DPDT) 2 C/O Timing Range(1) On-delay Off-delay (DPDT) 2 C/O (DPDT) 2 C/O 0.05 s...60 hr Off-delay (DPDT) 2 C/O (1) The time range of "0.05 s...60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs. Input Voltage 12V DC 24...48V DC 24...240V AC, 50/60 Hz 12V DC 24...48V DC 24...240V AC, 50/60 Hz Single Function With Hazardous Location Certification(1) (With SPDT 1 C/O contacts) Operating Mode One Shot / Watch Dog (Pulse Controlled) Contact Output (SPDT) 1 C/O Timing Range 0.05 s...1 s 0.5 s...10 s Input Voltage 24...48V DC 24...240V AC 50/60 Hz Cat. No. 700-FSA4UZ12 700-FSA4UU23 700-FSB4UZ12 700-FSB4UU23 Cat. No. 700-FSK3AU23-EX 700-FSK3CU23-EX 96 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Multi-Function This device allows the flexibility of selecting one of 8 single timing functions. Operating Mode Contact Output (SPDT) 1 C/O Multi-function timing relays 8 Single-functions: A, B, C, D, E, F, I, and L ON and OFF function additional (for installation and maintenance) note: See connection diagrams for further description. (SPDT) 1 C/O (DPDT) 2 C/O (DPDT) 2 C/O Timing Range 0.05 s...60 hr Input Voltage 12V DC 24...48V DC 24...240V AC 50/60 Hz 12V DC 24...48V DC 24...240V AC 50/60 Hz Cat. No. 700-FSM3UZ12 700-FSM3UU23 700-FSM4UZ12 700-FSM4UU23 Multi-Function With Hazardous Location Certification (1) This device allows the flexibility of selecting one of 8 single timing functions. Operating Mode M Multi-function timing relays 8 Single-functions: A, B, C, D, E, F, I, and L ON and OFF function additional (for installation and maintenance) Note: See connection diagrams for further description. Contact Output (SPDT) 1 C/O (DPDT) 2 C/O (1) The time range of "0.05 s...60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs. Timing Range(1) 0.05 s...60 h Input Voltage 24...48V DC 24...240V AC 50/60 Hz Cat. No. 700-FSM3UU23-EX 700-FSM4UU23-EX Special Function Operating Mode Contact Output Timing Range Flasher (repeat cycle starting with pulse or pause) (SPDT) 1 C/O 0.05 s...60 hr (2) 2 x 0.05 s...60 hr (2 ranges) OFF-delay without supply voltages (True OFF-delay)(1) (SPDT) 1 C/O (DPDT) 2 C/O 0.15 s...10 min(3) 0.5 s...10 s 1.5...30 s Star-Delta 2 N.O. + 1 Common 0.05 s...1 min 0.15...3 min 0.5...10 min (1) Due to shock during shipment, the state of the contacts should be verified before initial use. Minimum power on time is 800 msec. (2) The time range of "0.05 s...60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs. (3) This time range is selectable in four smaller ranges: 0.15 s...2.5 s, 0.5 s...10 s, 4 s...80 s, 30 s...10 min. Input Voltage 12V DC 24...48V DC 24...240V AC 50/60 Hz 12V DC 24...48V DC 24...240V AC, 50/60 Hz 24...240V DC 24...240V AC 50/60 Hz 24...48V DC 24...240V AC 50/60 Hz Cat. No. 700-FSH3UZ12 700-FSH3UU23 700-FSH3VZ12 700-FSH3VU23 700-FSQ3QU18 700-FSQ4QU18 700-FSY2CU23 700-FSY2DU23 700-FSY2EU23 700-FSY2FU23 700-FSY2GU23 (1) Temp. Code T4A 2A 32VDC MAX.: II 3 G, EEx nL IIC T4 DEMKO 04 ATEX 0404974X 2A 32VDC MAX. Ta 70 °C Ind. Cont. Eq. for Hazardous Location Listed 87SL Class 1, Div. 2, Groups A,B,C,D Class 1, Zn 2, Group IIC Subject devices are to be installed in an ATEX Certified IP54 (as defined in IEC 60529) enclosure and accessible only by the use of a tool. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 97 Relay and Timer Specifications Multi-Function Timing Relay Function and Time Range Settings - 700-FS Relays Description SPDT DPDT (1) For installation and maintenance. Multi-function timing relays 700-FSM3U includes 10 setting functions: Multi-Time Setting Range 0.05 s...60 h (A)On-Delay (B)Off-Delay (C)On- and Off-Delay (D)One shot (E)Fleeting Off-Delay (F)Flasher (repeat cycle starts with pulse) (I)On-Delay pulse generator (L)Pulse converter (On)ON-Function (1) (Off)OFF-Function(1) (1 s) 0.05...1 s (3 s) 0.15...3 s (10 s) 0.5...10 s (1 min) 0.05...1 min (3 min) 0.15...3 min (10 min) 0.5...10 min (1 hr) 0.05...1 hr (3 hr) 0.15...3 hr (10 hr) 0.5...10 hr (60 hr) 3....60 hr Note: Switch is on DPDT relays only. When switch is down, one contact is instantaneous and one is timed. When switch is up, both contacts are timed. Accessories - 700-FS Relays Description Pkg. Quantity Cat. No. Setting Knob with Scale (for time setting without tools) 10 700-FSK Panel Mounting Adapter For surface mounting according to drilling plan EN 50 002 5 199-FSA Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm 10 100-FMS Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent 10 cover 100-FMP Transparent Cover To be used with marking tag sheets 100 100-FMC Marking Tag Adapters To be used with marking tag: System 1492 W 100 (1) 100-FMA2 (1) Cat. No. 100-FMA2 is only a marking tag carrier. Please refer to the Terminal Block Accessories section, Marking Solutions of this publication for appropriate marker cards to be used with this carrier. IMPORTANT Versatile Mounting: The 700-FS timing relay can be panel or DIN rail mounted. For best long-term performance, allow at least 5 mm (0.2 in.) of space on each side of the relay for proper ventilation. 98 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Function and Connection Diagrams - 700-FS Relays (A) On-Delay Relay and Timer Specifications (G) Flasher (Repeat Cycle Starts with Pause) Output (B) Off-Delay (Min. Pulse AC 50 ms...DC 30 ms) (C) On- and Off-Delay Output LED (D) One Shot (1) (3) Output (3) (E) Fleeting Off-Delay (Min. Pulse AC 50 ms...DC 30 ms) (1) Output t LED (3) (F) Flasher (Repeat Cycle Starts with Pulse) (I) On-Delay Pulse Generator Output LED (3) (J) On-Delay (Pulse Controlled) (1) Output LED (K) One Shot/Watch Dog (Pulse Controlled) (1) Output LED (On) ON-Function (Off) OFF-Function Output 1 Output 2 LED Output 1 Output 2 LED (L) Pulse Converter (Min. Pulse AC 50 ms...DC 30 ms) (1) Output LED (3) Output (1) Cleverly Designed Function Display light-emitting diode (Green) (3) Output in Rest Position, No Timing Output in Rest Position, Time Running Output in Operation Position, No Time Running Output in Operation Position, Time Running (1) A voltage other than the supply voltage can be used at B1, but must be within voltages specified on timer. (2) Output 2 is selectable as instantaneous contact with sliding switch () on front panel (instantaneous when switch is down, timed when switch is up). (3) Available on multifunction "M," and single function "A" or "B" option timing relays along with code "4" (2PDT contacts). Bridge or potentiometer 10 k, 0.25 W min. (low voltage) for external time setting. Set timer dial to 0.0. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 99 Relay and Timer Specifications Special Function Flasher Timing Relay Description 1 Range Setting 700-FSH3U t2 Setting Up Down Switch Seperate Range Settings t1 Setting 700-FSH3V Supply Voltages (A1/A2) Z12 12V DC U23 24...48V DC, 24...240V AC, 50/60 Hz Function Diagram / Connection Diagram(1) (H) Flasher (Repeat Cycle Starting with Pulse or Pause) The repeat cycle timer permits different settings for on and off times. The following operating modes are possible: · Oscillating mode; repeat cycle starts with voltage that is applied at A1 and B1, and continues to repeat until voltage is off. · One cycle mode; started by energizing B1 with voltage on A1 and A2. · Output starts with pulse or pause (switch Up or Down). · 700-FSH3U provides (1) range setting for t1 and t2 700-FSH3V provides (2) range settings for t1 and t2 Supply Voltage Controlled, Oscillating Mode Starting with Pause -- Switch Is up Supply Voltage Controlled, Oscillating Mode Starting with Pulse -- Switch is Down U A1/A2 S A1/B1 t2 t2 Output t1 t1 151186 LED A1 B1 15 A2 18 16 U A1/A2 S t1 t1 A1/B1 Output t2 t2 15 18 16 LED A1 B1 15 A2 18 16 Pulse Controlled, Output Starts With Pause (Min. Pulse AC 50 ms -- DC 30 ms) -- Switch is Up One Cycle Mode -- Voltage Supplied at A1 and A2, then Pulsing "s" to Energize B1 will Initiate One Cycle. Pulse Controlled, Output Starts with Pulse (Min. Pulse AC 50 ms -- DC 30 ms) -- Switch is Down One Cycle Mode -- Voltage Supplied at A1 and A2, then Pulsing "s" to Energize B1 will Initiate One Cycle. U S Output LED A1/A2 A1/B1 t2 t1 t1 t2 151186 S A1 B1 15 A2 18 16 U S Output LED t1 t2 A1/A2 A1/B1 t1 t2 151186 s A1 B1 15 A2 18 16 (1) If B1 is pulsed, a one full time cycle consisting of t1 and t2 is completed. LED Operation Chart Ñ Green LED LED Output at Shelf State, No Timing - LED OFF LED Output at Shelf State, Time is Running - LED Flashing LED Output NO Contact is Closed, No Timing - LED On LED Output NO Contact is Closed, Time is Running - LED Long Flashing 100 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Function Diagram / Connection Diagram(1) (Q) Off-Delay without Supply Voltage (True Off-Delay) · When input power is turned on, the output contact changes state. When the power is removed, the time delay begins. The output contact returns to shelf state at the end of the time delay. U tp Output t LED A1/A2 151186 A1 15 A2 18 16 U tp Output 1 t Output 2 t LED A1/A2 A1 18 15 16 25 28 26 A2 15 25 18 16 28 26 (Y) Star-Delta Timing Relay · When power is applied, the output contact 17/18(Y) changes state. After the time setting, the output contact 17/18(Y) returns to shelf state. After the fixed time (50... 60 ms), the output contact 17/28 changes state. Both output contacts return to shelf state whenever the power is removed. (1) Min. pulse (tp) required: 800 ms U A1/A2 t 17/18 17/28 tu = 50...65 ms LED A1 17 A2 18 28 Specifications - 700-FS Relays(1) Attribute Setting Accuracy Repeatability Tolerance Value ±5% of full scale ±0.2% of the setting values Voltage: ±0.001%/%U Temperature: ±0.025%/°C Supply Attribute Supply Voltages Voltage Tolerance Power Consumption Time Energized Reset Time Voltage Interruption Input Impedance Cable Length (Supply Voltage Control) Pulse Control (B1) Value 24...48V DC and 24...240V AC, 50/60 Hz (multi voltage) 20...+20% (DC), 15...+10% (AC) 0.5 W at 24V DC, 5 VA at 240V AC 100% 50 ms 20 ms without reset (supply voltage) Relay ON: 3K-13K ohms, Relay OFF: 0.7K-4K ohms Max. 250 m (800 ft) Attribute Pulse Duration Input Voltage Value 50 ms (AC), 30 ms (DC) Supply voltage range Input Current Max. Leakage Current Cable Length 1 mA 400 micro Amps Max. 250 m (800 ft) without parallel load between B1 and A2, Max.50m(160ft)withload(<3 k) betweenB1andA2 Outputs Contact Type Dielectric Coil to Contact Switching Capacity Short-Circuit Resistance Relay as changeover switch 5000 V Voltage: 440V AC Current Ith (AC-1): 8 A (5 A for 700- FSQ) Power: 2000 VA According to IEC 947-5-1: 3 A/440V AC (inductive load, AC 14) 3 A/250V AC (inductive load, AC 15) 1 A/24V DC (inductive load, DC 13) According to UL 508: 1.5 A/250V AC (B300) 3 A/120V AC (B300) 10 A gL (1) Time Characteristics (according to VDE 0435, Part 2021) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 101 Relay and Timer Specifications Life State Indicator Mechanical: 30 million operations Electrical operations: 4 mil at 1 A/250V AC, cos = 1 0.2 mil at 6 A/250V AC, cos = 1 1.5 mil at 1 A/250V AC, cos = 0.3 0.3 mil at 3 A/250V AC, cos = 0.3 0.5 mil at 6 A/24V DC, resistive 2 mil at 4 A/24V DC, resistive 2 mil at 0.2 A/230V DC, resistive 1 mil at 0.4 A/24V DC, L/R = 20 ms 1 mil at 0.2 A/110V DC, L/R = 20 ms 1 mil at 0.1 A/230V DC, L/R = 20 ms 1 LED, combination signal General Data- 700-FS Relays Insulation Characteristics EMC/Interference Immunity EMC/Emission Safe Isolation Climatic Withstand Vibration Resistance Shock Resistance Protection Class Weight Approval Ambient Temperature Terminals Mounting Disposal Certifications Standards 2 kVAC/50 Hz test voltage according to VDE 0435 and 6 kV 1.2/50 s surge voltage according to IEC 947-1 between all inputs and outputs Performance of following requirements: Surge capacity of the supply voltage according to IEC 1000-4-5: 4 kV 1.2/50 s Burst according to IEC 1000-4-4: 6 kV 6/50 ns ESD discharge according to IEC 1000- 4-2: Contact 8 kV, air 8 kV Electromagnetic HF field according to IEC 801-3 and conducted electromagnetic HF signal according to IEC 801-6: Level 3 Electromagnetic fields according to EN 55 022: class B According to VDE 106, part 101 56 Cycles (24 hr) at 25...40 °C and 95% relative humidity according to IEC 68-2-30 and IEC 68-2-3 4 g in three axes at 10...500 Hz, test FC according to IEC 68-2-6 50 g according to IEC 68-2-27 Enclosure: IP40 IP 30 (Single-function) Terminal: IP 20 according to IEC 947-1 100 g UL, C-UL Open: 25...+60 °C Enclosed: 25...+45 °C Storage: 40...+85 °C Screw terminal M3.5 for Number 2 Posidriv, Philips, and slotted screws. Suitable for power screwdriver. Rated tightening torque 8.8 lb.-in. (0.8 N·m, max. 1.2 N·m). Dual-chamber system for terminal cross-sections of 1 x 0.5 mm2...2 x 2.5 mm2 (solid) or stranded 2 x 2.5 mm2 (flexible with sleeve), #20...14 AWG. Finger protection according to VDE 0106. Front mounting; For snap-on mounting on 35 mm DIN Rail or screw fixing by adapter and 2 screws (M4 type) Synthetic material without dioxin according to EC/EFTA notification Number 93/0141/D electrical contacts with cadmium cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14 Temp. Code T4A 2A 32VDC MAX. Mounting: Product shall be installed in an enclosure constructed in accordance with the requirements of EN50021. 102 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-HNC Miniature Timing Relay · Miniature timer, perfect for converting 700-HC "Ice Cube" relays into timing relays · 4 operating modes · 4PDT contact output · Timing range from 0.1 s...10 hr · Socket mounted Model Cat. No. 700-HNC Timing Mode Contact Output On-Delay One Shot Repeat cycle, OFF-start 4PDT Repeat cycle, ON-start Input Voltages 12V DC 24V DC 48V DC 100...110V DC 125V DC 24V AC 100...120V AC 200...230V AC Timing Range 0.1 s...10 min .1 min...10 hr 0.1 s...10 min 0.1 min....10 hr 0.1 s...10 min 0.1 min....10 hr 0.1 s...10 min 0.1 min....10 hr 0.1 s...10 min 0.1 min....10 hr 0.1 s...10 min 0.1 min....10 hr 0.1 s...10 min 0.1 min....10 hr 0.1 s...10 min 0.1 min....10 hr Socket Type 700-HN103 700-HN128 Cat. No. 700-HNC44AZ12 700-HNC44BZ12 700-HNC44AZ24 700-HNC44BZ24 700-HNC44AZ48 700-HNC44BZ48 700-HNC44AZ11 700-HNC44BZ11 700-HNC44AZ25 700-HNC44BZ25 700-HNC44AA24 700-HNC44BA24 700-HNC44AA12 700-HNC44BA12 700-HNC44AA23 700-HNC44BA23 Accessories - 700-HNC Relays Photo Description Pkg. Quantity Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting. Guarded Terminal Construction 14-Blade miniature socket for use with 700-HNC timers. 10 700-HN103 Screw Terminal Base Sockets -- Panel or DIN Rail Mounting. Open Style Construction 10 14-blade miniature socket for use with 700-HNC timers. Screw Terminal Socket Panel or DIN Rail Mounting. Guarded Terminal Construction 14-blade miniature socket for use with 700-HNC timers. This socket has coil 10 and contact separation. Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HNC Timers. Secures Timer in Socket. 10 700-HN128 700-HN104 700-HN263 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 103 Relay and Timer Specifications Specifications - 700-HNC Relays Attribute Pilot Duty Rating Pin type Operating voltage range Reset voltage Power consumption Control outputs Characteristics Make 120V AC 240V AC Break 120V AC 240V AC Hp at 120V AC Hp at 240V AC Accuracy of operating time Setting error Reset time Influence of voltage Influence of temperature Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature 104 700-HNC NEMA B300 Plug-in 85%...110% of rated supply voltage (12V DC: 90%...110% of rated supply voltage) (1) 10% min. of rated supply voltage 24V AC: Relay ON: Relay OFF: 1.5 VA(1.1 W) (at 24V AC, 60 Hz) 0.2 VA(0.1 W) (at 24V AC, 60 Hz) 100...120V AC: Relay ON: Relay OFF: 1.5 VA(1.3 W) (at 120V AC, 60 Hz) 0.8 VA(0.5 W) (at 120V AC, 60 Hz) 200...230V AC: Relay ON: Relay OFF: 1.8 VA(1.5 W) (at 230V AC, 60 Hz) 1.2 VA(0.9 W) (at 230V AC, 60 Hz) 12V DC: Relay ON: Relay OFF: 0.9 W (at 12V DC) 0.07 W (at 12V DC) 24V DC: Relay ON: Relay OFF: 0.9 W (at 24V DC) 0.07 W (at 24V DC) 48V DC: Relay ON: Relay OFF: 1.0 W (at 48V DC) 0.2 W (at 48V DC) 100...110V DC: Relay ON: Relay OFF: 1.3 W (at 110V DC) 0.3 W (at 110V DC) 125V DC: Relay ON: Relay OFF: 1.3 W (at 125V DC) 0.3 W (at 125V DC) 4PDT: 5 A at 250V AC, resistive load (cos = 1) 30 A 15 A 3 A 1.5 A 1/6 Hp 1/6 Hp ±1% FS max. (1 s range: ±1%±10 ms max.) ±10%±50 ms FS max. Min. power-opening time: 0.1 s max. (including halfway reset) ±2% FS max. ±2% FS max. 100 m min. (at 500V DC) 2000V AC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts) (2) 2000V AC, 50/60 Hz for 1 min (between operating power circuit and control output) 2000V AC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model) 1500V AC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model) 1000V AC, 50/60 Hz for 1 min (between non-continuous contacts) Malfunction: 10...55 Hz, 0.5 mm single amplitude Malfunction: 100 m/s2 (approx. 10G) Operating: -10 °C...50 °C (with no icing) Storage: -25 °C...65 °C (with no icing) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Attribute 700-HNC Ambient humidity Operating: 35%...85% Life expectancy Mechanical: 10 000 000 operations min. (under no load at 1800 operations/hr) Electrical: 4PDT: 200 000 operations min. (3 A at 250V AC, resistive load at 1800 operations/hr) Noise immunity ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns / 1 s, 1- ns rise) Static immunity Enclosure rating Destruction:8 kV Malfunction:4 kV IP40 Weight Approx. 50 g Emission Enclosure:EN55011 Group 1 class A Emission AC Mains:EN55011 Group 1 class A Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3) EMC Immunity RF-interference:ENV50140:10 V/m (amplitude modulated, 80 MHz to 1 GHz) (level 3) 10 V/m (pulse modulated, 900 MHz) Immunity Conducted Disturbance:ENV50141:10 V (0.15...80 MHz) (level 3) Immunity Burst:EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Standards UL 508, CSA 22.2 No. 14, EN/IEC 61812-1 Certifications cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CSA Certified (File 224268), CE Marked, C- Tick Marked (1) Single-phase, full-wave-rectified power supplies can be used. (2) When using the 700-HNC continuously in any place where the ambient temperature is in a range of 45 °C...50 °C, supply 90%...110% of the rated supply voltages supply 95%...110% with 12V DC type). General Timer Functions Rockwell Automation Publication 700-TD552F-EN-P - January 2021 105 Relay and Timer Specifications Timing Charts - 700-HNC Relays IMPORTANT t: Set time, Rt:Reset time Operating Mode ON-Delay Power t Output One shot Power Output Repeat Cycle OFF-Start Power Output t t t Repeat Cycle ON-Start Power t t t Output General Timer Functions Output Indicator (Orange) (Lit: Output ON) Main Dial Set the desired time according to time range selectable by DIP switch. Timing Charts / Wiring Diagram t Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run / Power Indicator (PW) Output Indicator (UP) Rt t Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run / Power Indicator (PW) Output Indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run / Power Indicator (PW) Output Indicator (UP) t t t t t t t t Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run / Power Indicator (PW) Output Indicator (UP) Timer Circuit UP PW Pulse Operation A pulse output for a certain period can be obtained with a random external input signal. Use the 700-HNC timing relay in interval mode as shown in the following timing charts. Run/Power Indicator (Green) (Lit: Power ON) 1 2 3 4 5 6 7 8 9 10 11 12 13 Timer 14 (--) Circuit (+) (~) (~) UP FW External Input ~ ( ) Power (9-14) External short circuit (5-13) External input (9-13) Time limit contact NO (10-6, 11-7, 12-8) Time limit contact NC (10-2, 11-3, 12-4) Run/Power indicator (PW) Output indicator (UP) 50 ms min. Note: t: Set time Rt: Reset time 106 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 DIP Switch Settings - 700-HNC Relays Time Ranges Cat. No. 700-HNC44AZ12 700-HNC44AZ24 700-HNC44AZ48 700-HNC44AZ11 700-HNC44AZ25 700-HNC44AA24 700-HNC44AA12 700-HNC44AA23 Time Range 1 s 10 s 1 min 10 min 700-HNC44BZ12 700-HNC44BZ24 700-HNC44BZ48 700-HNC44BZ11 700-HNC44BZ25 700-HNC44BA24 700-HNC44BA12 700-HNC44BA23 1 min 10 min 1 hr 1 hr Note: The top two DIP switch pins are used to select the time ranges. Time Setting Range 0.1 s...1 s 1 s...10 s 0.1 s...1 min 1...10 min 0.1...1 min 1...10 min 0.1...1 hr 1...10 hr Relay and Timer Specifications Setting Factory-Set Yes No No No Yes No No No Operating Mode ON-delay One Shot Repeat Cycle OFF-start Repeat Cycle ON-start Note: The top two DIP switch pins are used to select the time ranges. Setting Factory-set Yes No No No Rockwell Automation Publication 700-TD552F-EN-P - January 2021 107 Relay and Timer Specifications Dimensions - 700-HNC Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 4.0 (0.15) Fourteen 3 x 1.2 mm Elliptic Holes 52.6 (2.07) 63.0 (2.48) 6.4 (0.25) Cat. No. 700-HNC... 28 (1.10) 6.3 (.024) 21.5 max (084) Panel Mounting 24.5 (31/32) 28.9 (1-9/64) 67.0 (2-5/8) 30.0 (1-11/64) #4-40 M3 Cat. No. 700-HN103 Single wire: 0.2...2.5 mm2 (#24 AWG...14 AWG) Double wire: 2 x 0.2 mm2...2 x 1.5 mm2 (2 x 24 AWG...2 x 16 AWG) Wire type: solid or stranded, copper only Strip length: 8 mm (5/16 in.), Torque: 0.5 N·m (4.4 lb·in) (1) Total height of 700-HN128 + 700-HNC is 82.5 mm. 30.0 (1-3/16) 6.1 (15/64) 8765 4321 24.9 (57/64) 21.1 (53/64) 4.2 (5/32) 62.0 (2-15/64) 14 13 12 11 10 9 65.0 (2-9/16) 26.0 (1-1/64) Cat. No. 700-HN128 (1) Wire Size: 2 x 1.5 mm2 (#2-16 AWG...#1-20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) - Torque: 0.8 N·m (7 lb·in) 27.0 (1.06) 60.9 (2.40) 21.5 (0.85) 76.0 (2.99) 34.9 (1.37) 3.2 (0.13) 2.5 (0.10) 35.6 (1.40) 32.0 (1.26) 35.5 (1.40) 18.9 (0.74) Cat. No. 700-HN104 Single Wire: 0.2...2.5 mm2 ( #24 AWG...14 AWG) Double Wire: 2 x 0.2 mm2...2 x2.5 mm2 (2 x 24 AWG...2 x 14 AWG) Wire Type: solid or stranded, copper only Strip Length: 7 mm (9/32 in.), Torque: 0.5 N·m (4.4 lb·in) 108 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-HNK Ultra-Slim Timing Relay · The ultra-slim timing relay is the smallest relay available · It is perfect for converting 700-HK relays into a timing relay · SPDT and DPST-NO contact output · Socket-mounted · Timing range From 0.1 s...10 hr Photo Timing Mode Socket Type Contact Output 700-HN121 On-Delay One Shot Repeat Cycle, OFF-start Repeat Cycle, ON-start 700-HN122 SPDT (1) DPST-NO(2) (1) 5-blade terminal type only. (2) 8-blade terminal type only. Accessories - 700-HNK Relays Description Timing Range 0.1 s...10 min 0.1 min...10 hr 0.1 s...10 min 0.1 min...10 hr Input Voltage 12V DC 24V DC 24V AC 12V DC 24V DC 24V AC 12V DC 24V DC 24V AC 12V DC 24V DC 24V AC Cat. No. 700-HNK41AZ12 700-HNK41AZ24 700-HNK41AA24 700-HNK41BZ12 700-HNK41BZ24 700-HNK41BA24 700-HNK42AZ12 700-HNK42AZ24 700-HNK42AA24 700-HNK42BZ12 700-HNK42BZ24 700-HNK42BA24 Pkg. Quantity Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting 5-blade miniatue socket. For use with 1-pole type 700-HNK41 timers. Socket includes a retainer clip. 10 700-HN121 Screw Terminal Socket -- Panel or DIN Rail Mounting 8-blade miniature socket for use with 2-pole, 700-HNK42 timers. This socket includes a retainer clip. 10 700-HN122 Sockets and Retainer Clip Reference Timer Type 700-HNK Socket Cat. No. 700-HN121 700-HN122 Retainer Clip Cat. No. Provided Provided Rockwell Automation Publication 700-TD552F-EN-P - January 2021 109 Relay and Timer Specifications Specifications - 700-HNK Relays Attribute Pilot Duty Rating Rated Supply Voltage Pin Type Operating Mode Operating Voltage Range Power Consumption Control Outputs Characteristics Make 120V AC 240V AC Break 120V AC 240V AC Hp at 240V AC Accuracy of Operating Time Setting Error Reset Time Influence of Voltage Influence of Temperature Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance Ambient Temperature Ambient Humidity Life Expectancy Impulse Withstand Voltage Noise Immunity Static Immunity Enclosure Rating Weight 700-HNK NEMA B300 24V AC; 12, 24V DC Plug-in ON-delay, One Shot, Repeat Cycle OFF start, or Repeat Cycle ON start selectable with DIP switch. 85%...110% of rated supply voltage (12 VDC: 90%...110% of rated supply voltage) (1) 24V AC:Relay ON:approx. 0.8 VA (at 24 VAC, 60 Hz) Relay OFF:0.5 VA (at 24V AC, 60 Hz) 12V DC:Relay ON:approx. 0.4 W (at 12V DC) Relay OFF:0.1 W (at 12V DC) 24V DC:Relay ON:approx. 0.5 W (at 24V DC) Relay OFF:0.2 W (at 24V DC) 5 A at 250V AC, resistive load (cos = 1) The minimum applicable load is 10 mA at 5 VDC (P reference value). 30 A 15 A 3 A 1.5 A 1/6 Hp ±1% FS max. (1 s range: +1% ±10 ms max.) ±15% +50 ms FS max. Min. power-opening time: 12, 24V DC: 0.1 s max. (including halfway reset) 24V AC: 0.5 s max. (including halfway reset) ±2% FS max. ±2% FS max. 100 m min.(at500VDC) 2000V AC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of different poles) 1000V AC, 50/60 Hz for 1 min (between non-continuous contacts) Malfunction: 10...55 Hz, 0.5 mm single amplitude Malfunction: 100 m/s2 (approx. 10G) Operating: -10 °C...50 °C (with no icing) Storage: -25 °C...65 °C (with no icing) Operating: 35...85% Mechanical: 10 000 000 operations min. (under no load at 1800 operations/hr) Electrical: 100 000 operations min. (3 A at 250V AC, resistive load at 1800 operations/hr) Between power terminals: 1 kV ±1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Destruction: 8 kV Malfunction: 4 kV IP20 Approx. 18 g 110 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Attribute 700-HNK Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A Immunity ESD: EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3) EMC Immunity RF-interference: ENV50140: 10 V/m (amplitude modulated, 80 MHz...1GHz) (level 3) 10 V/m (pulse modulated, 900 MHz) Immunity Conducted Disturbance: ENV50141:10 V (0.15...80 MHz) (level 3) Immunity Burst: EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Standards UL508, CSA C22.2 No. 14, EN/IEC 60947-5-1, EN/IEC 61812-1 Certifications cURus Recognized Component (File No. E14843, Guide NRNTZ/NRNT8), CE Marked, C-Tick Marked (1) When using 700-HNK timer in any place where the ambient temperature is more than 50 °C, supply 90...110% of the rated voltages (12V DC: 95...11% of the rated voltage). IMPORTANT t: Set time, Rt:Reset time General Timer Functions Run/Power Indicator (Green) (Lit: Power ON) Output Indicator (Orange) (Lit: Output ON) Main Dial Set the desired time according to time range selectable by DIP switch. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 111 Relay and Timer Specifications Operating Mode ON-Delay Power t Output Power (1-5) Time limit contact NC (4-2) Time limit contact NO (4-3) Run/ Power Indicator (PW) Output Indicator (OUT) 700-HNK41... Timing Charts / Wiring Diagram 700-HNK42... t Rt t Power (1-8) Time limit contact NO 4-3, 5-6 Run/Power indicator (PW) Output indicator (OUT) t Rt t One shot Power Output Repeat Cycle OFF-Start Power Output t t t Repeat Cycle ON-Start Power t t t Output Power (1-5) Time limit contact NC (4-2) Time limit contact NO (4-3) Run/ Power Indicator (PW) Output Indicator (OUT) Power (1-5) Time limit contact NC (4-2) Time limit contact NO (4-3) Run/ Power Indicator (PW) Output Indicator (OUT) t t Power (1-5) t t Time limit contact NC (4-2) Time limit contact NO (4-3) Run/ Power Indicator (PW) Output Indicator (OUT) t t t t t Power (1-8) Time limit contact NO (4-3, 5-6) Run/Power indicator (PW) Output indicator (OUT) Rt t Power (1-8) Time limit contact NO (4-3, 5-6) Run/Power indicator (PW) Output indicator (OUT) t t t t Power (1-8) Time limit contact NO (4-3, 5-6) Run/Power indicator (PW) Output indicator (OUT) t t t t 112 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Wiring- 700-HNK Relays Relay and Timer Specifications 3 4 5 4 3 6 Timer ~ ~ 1 Circuit ( ) 8 ( ) ( ) OUT PW ( ) Cat. No. 700-HNK42... 2 Timer 1 Circuit 5 ( ) ( ) ( ~ ) OUT PW ( ~ ) Cat. No. 700-HNK41... A pulse output for a certain period can be obtained with a random external input signal. Use the 700-HNK in interval mode as shown in the following timing chart. 4 5 3 6 1 Timer 8 ~( ) Circuit ( ) OUT PW ( ) ( ~) ~ External Input ( ) Mode Pulse Operation Operating mode; One shot and all other modes Power (3-8) External Short Circuit (1-4) External Input (1-3) Time Limit Contact NO (6-5) Run/Power Indicator (PW) Output Indicator (OUT) Rt Rt t t t 50 ms min. Note:t:Set time Rt: Reset time Terminals Power supply between 3 and 8 Short-circuit between 4 and 1 Input signal between 3 and 1 Power supply between 1 and 8 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 113 Relay and Timer Specifications Time Ranges- 700-HNK Relays Cat. No. 700-HNK41AZ12 700-HNK41AZ24 700-HNK41AA24 700-HNK42AZ12 700-HNK42AZ24 700-HNK42AA24 Time Range 1 s 10 s 1 min 10 min 700-HNK41BZ12 700-HNK41BZ24 700-HNK41BA24 700-HNK42BZ12 700-HNK42BZ24 700-HNK42BA24 1 min 10 min 1 hr 10 hr Note: The left two DIP switch pins are used to select the time ranges. Time Setting Range 0.1...1 s 1...10 s 0.1 s...1 min 1...10 min 0.1...1 min 1...10 min 0.1...1 hr 1...10 hr Setting Factory-Set Yes No No No Yes No No No Operating Modes - 700-HNK Relays Operating Mode On-delay One Shot Repeat Cycle Off-start Repeat Cycle On-start Note: The right two DIP switch pins are used to select the operating modes. Setting 114 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Factory-set Yes No No No Relay and Timer Specifications Dimensions - 700-HNK Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 12.8 (0.50) 28.8 (1.30) 31.2 (1.22) 47.4 (1.86) 46.0 (1.81) 6 (0.23) 12.8 (0.50) 31.2 (1.22) 28.8 (1.13) 47.0 (1.86) 46.0 (1.81) 6.0 (0.23) 700-HNK41 SPDT Contact 7.11 11 (9/32) Five M3.5 4 x 0.315 Screws 14 3 84.1 (3-5/16) 12 2 3.0 Ø (1) (1/8) Use M3 Screws 5 (+) (A1) 1 (-) (A2) 2.03 (5/64) 4.06 (5/32) 39.5 (1-17/32) 35.5 (1-13/32) 4.06 (5/32) 15.6 (5/8) 29.9 (1-3/16) 54.1 (2-1/8) Cat No. 700-HN121 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (#214 AWG... #220 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Total height: 700-HN121 + 700-HNK41 is 78.0 mm. (1) Holes required for mounting [3 mm (1/8 in.) diameter]. 700-HNK42 DPST-NO Contact 21 6 22 7 24 5 84.1 (3-5/16) 8 (+) (A1) 7.11 (9/32) 11 3 Eight M3.5 x 0.315 Screws 12 14 2 4 3.0 Ø (1) (1/8) Use M3 Screws 2.03 (5/64) 4.06 (5/32) 39.5 (1-17/32) 35.5 (1-13/32) 4.06 (5/32) 1 (-) (A2) 15.6 (5/8) 29.9 (1-3/16) 54.1 (2-1/8) Cat No. 700-HN122 Wire Size: 2 x 2.5 mm2 Single Wire Up to #12 AWG Double Wire 2 x 2.5 mm2 (#214 AWG... #220 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) Torque: 0.8 N·m (7 lb·in) Total height: 700-HN122 + 700-HNK42 is 78.0 mm. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 115 Relay and Timer Specifications 700-HR Dial Timing Relays · Socket- or panel-mounted · 5 A contact ratings or transistor outputs · Single- or Multi-Function · Timing range from 0.05 s...300 hr · Multi-voltage inputs Multi-Function Timing Relays with Trigger and Reset Switch Options · Socket or Panel Mounted · Timing Range From 0.05 s...300 hr · 11-pin base for socket cat. nos. 700-HN101, -HN126, -HN129 · Trigger: Power on or optional trigger signal · Reset: Power off or optional reset signal Timing Mode Supply Voltage On-Delay (A) OFF-Delay (D) One Shot (E) Repeat cycle OFF-Start (B) Repeat Cycle ON-Start (B2) Signal ON/OFF-delay (C) Delayed One Shot (J) Signal ON/OFF - Delay (G) 24...48V AC 12...48V DC 100...240V AC 100...125V DC Trigger Options 1. Power On 2. Start Signal - contact closure (zero volts) - NPN transistor 3. Gate Signal (pause) 1. Power On 2. Start Signal - contact closure (voltage) - NPN transistor - PNP transistor 1. Power On 2. Start Signal - contact closure (zero volts) 3. Gate Signal (pause) 1. Power On 2. Start Signal - contact closure (voltage) (1) Voltage input connection to high signal instead of OV signal. Reset Options 1. Power Off 2. Reset Signal - contact closure (zero volts) - NPN transistor Power Off 1. Power Off 2. Reset Signal - contact closure (zero volts) Power Off Outputs DPDT Transistor DPDT DPDT DPDT Cat. No. 700-HR52TU24 (1) 700-HRT6TTU24 700-HRV52TU24 700-HR52TA17 (1) 700-HRV52TA17 Multi-Function Timing Relays with Power On Trigger · Socket or Panel Mounted · Timing Range From 0.05 s...300 hr · 8-pin base for socket cat. nos. 700-HN100, -HN125, -HN108 · Trigger: Power on · Reset: Power off Timing Mode Supply Voltage ON-Delay (A) One Shot (E) Repeat Cycle OFF-Start (B) Repeat Cycle ON-Start (B2) Delayed One Shot (J) 24...48V AC 12...48V DC 24...48V AC/DC 100...240V AC 100...125V DC Trigger Options Power On Power On Power On Reset Options Power Off Outputs DPDT Transistor Power Off SPDT Timed + Instantaneous Contact Power Off SPDT Timed + Instantaneous Contact DPDT (1) Voltage input connection to high signal instead of OV signal. Cat. No. 700-HRS42TU24 700-HRT4TTU24 (1) 700-HRP42TU24 700-HRP42TA17 700-HRS42TA17 116 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications ON-Delay Timing Relays · Socket or Panel Mounted · Timing Range From 0.05 s...300 h · 8-pin base for socket cat. nos. 700-HN100, -HN125, -HN108 · Trigger: Power on · Reset: Power off Timing Mode Supply Voltage 24...48V AC/DC ON-Delay (A) 24...48V AC, 12...48V DC 100...240V AC Trigger Options Power On Power On Reset Options Power Off Power Off Outputs SPDT Timed + Instantaneous Contact DPDT DPDT SPDT Timed + Instantaneous Contact Timing Mode Description Cat. No. 700-HRC12TU24 700-HRM12TU24 700-HRM12TA17 700-HRC12TA17 700-HRF Repeat Cycle Timing Relays · Socket or Panel Mounted · Independently adjustable on- and off-time · 8-Pin base for socket cat. nos. 700-HN100, -HN125, and -HN108 · DPDT contact outputs · Trigger: Power on · Reset: Power off · Hazardous location version available Catalog Number Explanation 700 HRF 7 2 D U26 a b c d e f a Bulletin Number b Type of Relay 700 HRFRepeat cycle with adjustable ON/OFF times c Function 7Repeat cycle with OFF start 8Repeat cycle with ON start d Contact Output e Timing Range 2- DPDT D0.05 s...300 hr f Supply Voltage U26 - 12...48V DC, 24...48V AC U27 - 100...125V DC, 100...240V AC 700-HRY Star-Delta Timing Relays · 8-Pin base for socket cat. nos. 700-HN100, -HN125, and -HN108 · SPDT timed + instantaneous contact outputs · Trigger: Power on · Reset: Power off 700 HRYY 6 a b c Catalog Number Explanation F A12 d e a Bulletin Number b Type of Relay 700 HRYYYStar-Delta timer c Function 6SPDT timed + SPDT instant d Timing Range FStar: 0.5...120 s Delta: 0.05, 0.1, 1.25, 0.5, 0.75, 1.0 s e Supply Voltage A12100...120V AC, 50/60 Hz A22200...240V AC, 50/60 Hz Rockwell Automation Publication 700-TD552F-EN-P - January 2021 117 Relay and Timer Specifications 700-HRQ True Off-Delay Timing Relays · 11-Pin base for use with reset option -- socket cat. nos. 700-HN101, -HN126, and -HN129 · 8-Pin base for use without reset option -- socket cat. nos. 700-HN100, -HN125, and -HN108 · DPDT contact outputs · Trigger: Power off · Reset: optional reset signal 700 HRQ N 2 G A12 a b c d e f Catalog Number Explanation a Bulletin Number b - Type of Relay c Function d Contact Output e Timing Range 700 HRQTrue OffDelay Timer NNo reset option, 8-pin terminals RReset option, 11-pin terminals 2DPDT G0.05...12 s H0.05...12 min Accessories - 700-HR Relays Photo Description f Supply Voltage A12100...120V AC, 50/60 Hz A22200...240V AC, 50/60 Hz U2524V AC, 50/60 Hz; 24V DC Z4848V DC Z11100...125V DC Pkg. Qty. Cat. No. Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with 700-HR and -HX timing relays. 10 700-HN100 Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use with 700-HR and -HX timing relays. No retainer clip required. 10 700-HN125 Screw Terminal Tube Base Sockets -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 11-pin for use with 3PDT 700-HA relays. 10 700-HN101 Screw Terminal Tube Base Sockets -- Panel or DIN Rail Mounting; Open Style Terminal Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required. 10 700-HN126 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 118 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Photo Description Pkg. Qty. Cat. No. Specialty Socket 8-pin backwired socket with solder terminals for use with 700-HR timing relays. Order 10 or 10 multiples of 10. 700-HN108 Specialty Socket 11-pin back-wired socket with solder terminals for use with 700-HR timing relays. 10 700-HN129 Frame Adapter For flush or door mounting of all 700-HR and -HX timers. 1 700-HN130 Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with all 700-HR Timing Relays Secures timer in socket. 10 Note: Not required for installation 700-HN131 Protective Cover Helps prevent tampering of timing and mode settings. Provides a degree of protection against water and dirt from entering the front of the relay. For use with all 700-HRs and -HX timing 1 relays. Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank 10 tags. Tags are peel-off with sticky backing for easy placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing 10 for easy placement on relays. 700-HN132 700-N40 700-N41 Timer Type 700-HR52, -HRT6, -HRV, -HRQR 700-HRS, -HRT4, -HRP, -HRC, -HRM, -HRF, -HRY, -HRQN (1) 11 pins. (2) 8 + pins. (3) Design of these sockets holds the timing relays securely and does not require retainer clips. Socket Cat. No. 700-HN101 (1) 700-HN126 700-HN129 700-HN100 (2) 700-HN108 700-HN125 Retainer Clip Cat. No. 700-HN131 Not Required (3) Not Applicable 700-HN131(See note above) Not Applicable Not Required(3) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 119 Relay and Timer Specifications Specifications - 700-HR Relays Electrical Ratings Pilot Duty Rating Thermal Current (Ith) Make 120V AC 240V AC Break 120V AC 240V AC Hp at 120V Hp at 240V Resistive Load Inductive Load Accuracy of Operating Time Setting Error Influence of Voltage Influence of Temperature Permissible Leakage Current Power Consumption 240V AC, Output ON 240V AC, Output OFF 24V DC, Output ON 24V DC, Output OFF Design Specifications Dielectric Strength Mechanical Vibration Resistance Shock Resistance Environmental Noise Immunity Static Immunity Ambient Temperature Ambient Humidity Construction Life Rxpectancy (Min. Operations) 700-HR, 700-HRS, 700-HRV 700-HRP 700-HRC 700-HRM 700-HRF 700-HRY 700-HRQ 700-HRT (Transistor Outputs) NEMA B300 -- 5 A 100 mA @ 30V DC max. 30 A -- 15 A -- 3 A -- 1.5 A -- 1/6 Hp (0.12 kW) 1/4 Hp (0.18 kW) 1/6 Hp (0.12 kW) 1/4 Hp (0.18 1/6 Hp (0.12 kW) kW) -- 1/3 Hp (0.25 kW) -- 5 A at 250V AC/30V DC AC-15 @ 250V AC, 3 A/DC-13 @ 30V DC, 0.5 A ±0.2% FS max. (±0.2% ±10 ms max. in a range of 1.2 s) ±5 % FS ±50 ms (The value is ±5% FS +100 ms to -0 ms max. when the C or D mode signal of the 700-HRVs are OFF.) ±0.2% FS max. (±0.2% ±10 ms max. in a range of 1.2 s) ±1% FS max. (±1% ±10 ms max. in a range of 1.2 s) -HR52, -HRS -HRV -HRP, -HRC -HRM -HRF -HRY -HRQ -HRT 2.1 VA 2.5 VA 2.0 VA 2.1 VA 10 VA 12 VA 0.4 VA -- 1.3 VA 1.8 VA 2.0 VA 1.3 VA 10 VA 12 VA 0.4 VA -- 0.8 W 0.9 W 0.9 W 0.8 W 1.0 W -- 0.2 W 0.3 W 0.2 W 0.3 W 0.9 W 0.2 W 1.0 W -- 0.2 W 0.2 W 2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (contact to frame) 2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (between control output terminals and operating circuit) 2000V AC, 50/60 Hz for 1 min (pole-to-pole) 1000V AC, 50/60 Hz for 1 min (between contacts not located next to each other) 2000V AC, 50/60 Hz for 1 min (contact to coil) Malfunction: 10...55 Hz with 0.5 mm double amplitude each in three directions for ten minutes each Malfunction: 100 m/s2 (10 G) 98 m/s2 (10 G) 294 m/s2 (10 G) 98 m/s2 (10 G) 100 m/s2 (10 G) ±1.5 kV for ±600V DC ±400V for 12V DC Malfunction: 8 kV Operating: -10...+55 °C ( 14...131 °F) with no icing Storage: -25...+65 °C ( 13...149 °F) with no icing Operating: 35...85 % Mechanical:20 000 000. (under no load at 1800 operations/h) Electrical: 100 000 (5 A at 250V AC, resistive load at 1800 operations/h) ±1kV for 48V DC ±1.5 kV for ±600V DC Mech: 107 Electrical: 104 120 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 EMC Degree of Protection Weight Certifications Standards Relay and Timer Specifications 700-HR, 700-HRS, 700-HRV 700-HRP 700-HRC 700-HRM 700-HRF 700-HRY 700-HRQ 700-HRT (Transistor Outputs) (EMI) EN50081-2 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN50082-2 Immunity ESD:EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: ENV50140:10 V/m (80 MHz...1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: ENV50204:10 V/m (900 ±5 MHz) (level 3) Immunity Conducted Disturbance: ENV50141: 10V (0.15...80 MHz) (level 3) Immunity Burst: EN61000-4-4:2 kV power-line (level 3) Immunity Surge: EN61000-4-52 kV I/O signal-line (level 4) 1 kV line to line; 2 kV line to ground (level 3) IP40 (panel surface) Approx. 90 g CSA Certified (File No. 70751), UL Recognized (File No. E14843 Guide No. NRNT2), CE Marked, C-Tick Marked UL 508, CSA C22.2 No. 14, EN 61812-1, EN 61000-6-2, -6-4 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 121 Relay and Timer Specifications Timer Functions - 700-HR Relays 700-HR Multifunction Timer Power indicator (green) (Flashes when Timer operates; lit when Timer stops operating) Operating mode display window Output indicator (orange) (Lit when energized) Operating mode selector Select a mode from: A, B, B2, C, D, E, J, and G (700-HR52, -HRV, and HRT 6) A, E, B2, J, and B (800-HRS, -HRP, and -HRT4) Scale range display windows Time Range selector (select one from 1.2, 3, 12, and 30 at full scale.) 700-HRC -HRM On-Delay Timer Time setting knob (set time) Time unit display window Time unit selector (select one from sec, 10 s, min, 10 m, hrs, and 10 h) Power indicator (green) (Flashes when Timer operates; lit when Timer stops operating) Output indicator (orange) (Lit when energized) 700-HRF Twin Timer Time Range selector (select one from 1.2, 3, 12, and 30 at full scale.) Time setting knob (set time) Scale range display windows Time unit display window Time unit selector (select one from sec, 10 s, min, 10 m, hrs, and 10 h) OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. Scale range display windows 700-HRY Star-Delta Timer Time range selector (select one from 1.2, 3, 12, and 30 at full scale.) OFF-time unit display OFF-time unit selector (select one from sec, 10 s, min., 10 m, hrs, and 10 h) ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting ON-time unit display ON-time unit selector (select one from sec, 10 s, min., 10 m, hrs, and 10 h) Star operation indicator (green) Delta operation indicator (orange) Scale range display windows Star operation time range selector (select one from 6, 12, 60 and 120 at full scale.) 700-HRQ True Off-Delay Timer Star-delta transfer time unit display Time unit display (sec. is fixed) Time setting knob (for setting star operation time) Star-delta transfer time selector (select one from 0.05 s, 0.1 s, 0.25 s, 0.5 s, 0.75 s and 1.0 s) Scale range display windows Output indicator (red) Time range selector (select one from 0.6, 1.2, 6, and 12 at full scale.) Time setting knob (for setting OFF-delay time) True OFF-Delay time unit display 122 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications for Start, Gate, Reset Signal (Cat. Nos. 700-HR52, -HRT6, -HRV, -HRQR) Start, Reset, and Gate signals are typically contact closures or signals from a solid-state sensor. (R) Reset Signal The reset signal is not required for normal operation. Reset can be accomplished by removing power from the timing relay. To reset the timer without removing power, a signal must be applied which resets the timing cycle and returns the output contacts to their shelf state. The reset signal will override both the start signal and gate signal. The reset signal can be either momentary or maintained. (G) Gate Signal The gate signal is not required for normal operation. The gate signal provides a pause or retentive timing function. When the gate signal is applied the timing cycle is momentarily interrupted. When the signal is removed, the timing cycle resumes timing at the point the cycle was interrupted and will continue timing until the time delay is completed or the gate signal is re-applied. Contact Signal -- Cat. Nos. 700-HR52, -HRT6, -HRQR Contact closure provides signal to timer. A low energy signal is generated by the 700-HR timing relay. For optimum reliability, use contacts designed for low energy switching (5V, 1 mA) (Bul. 800F-X V, 800T-X V). No external voltage should be connected to the contact signal. Contact Signal -- Cat. No. 700-HRV For use in applications where it is not possible to use contacts designed for low energy switching. Contact closure provides signal to timer. A signal is generated by the 700-HR timing relay, and is the same potential as the supply voltage of the timing relay. No external voltage should be connected to contact signal. 700HRV52TU24 supply voltage: 24...48V AC, 12...48V DC / 700-HRV52TA17 supply voltage: 100...240V AC, 100...125V DC. Solid-State Signal -- Cat. Nos. 700-HR52, -HRT6 Timing relay is suitable for use with a 3-wire NPN 12...24V DC sensor. Supply voltage potential of sensor must be the same as the supply voltage potential of the timing relay. Permissible off-state leakage current from sensor: 0.01 mA max. t1< T t1 Power to Timing Relay Reset Signal Timing Cycle Timing Relay Output t1 Power to Timing Relay Gate (pause) Timing Cycle Timing Relay Output R S G 5v, 1mA T t2 t1+t2 = T S U U ( ) ( + ) + 12...24V DC COM 0.1mA R S G COM ( ) (+) 12...24V DC Solid-State Signal -- Cat. No. 700-HRV Timing relay is suitable for use with a 3-wire NPN or PNP 12...24V DC sensor. Supply voltage potential of sensor must be the same as the supply voltage potential of the timing relay. Permissible off-state leakage current from sensor: 0.01 mA max. + 12...24V DC COM S + 12...24 V DC COM S PNP Wiring Diagram COM( ) (+) 12...24V DC NPN Wiring Diagram COM( ) (+) 12...24V DC Circuit Impedance Power-OFF Reset Signal Duration Signal Options Signal Specifications Circuit impedance can be used to calculate the maximum wiring distance from the signal switch to the timing relay, for example. Permissiblesignal-ONimpedance:1 k max. Permissible signal-OFF impedance: 100 k min. Min. power-off time: 0.1 s, Reset Voltage: 10% max. of rated voltage Min. pulse width: 0.05 s 700-HR52 700-HRT6 700-HRV5 700-HRQR Start X X X NA Reset X X NA X Gate X X NA NA Rockwell Automation Publication 700-TD552F-EN-P - January 2021 123 Relay and Timer Specifications Timing Charts - 700-HR Relays Mode A -- ON-Delay a. Needs continuous input power applied. b. Timing is initiated by the leading edge of the start signal. c. Contacts change state after timing is complete. d. Additional start signals during timing don't reset timing or contacts. e. When the input power is removed contacts return to shelf state. T Power Start Output (N.C.) Output (N.O.) Basic Operation T Power Start Output Power LED Mode B -- Repeat Cycle, Off Start a. Need continuous input power applied. b. Timing is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts. c. For the first time period the contacts remain in their shelf state. When that time period is complete contacts change state for the same time period (time on = time off). d. This cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state. Basic Operation Power Start Output (N.C.) Output (N.O.) Power LED T T T Power Start Output T T T Mode B2 --Repeat Cycle On start a. Need continuous input power applied. b. Timing is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts. c. For the first time period the contacts change state. When that time period is complete contacts return to the shelf state for the same time period (time on = time off). d. This cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state. Basic Operation Power Start Output (N.C.) Output (N.O.) Power LED TTT Power Start Output T T T Mode C -- Watchdog monitor (Trigger = Signal On/Off ) a. Need continuous input power applied. b. Contacts change state immediately when start signal is applied or when start signal is removed (only if timing cycle was complete). c. Timing is initiated at the leading edge of the start signal. After the first timing cycle is complete, timing is initiated by the trailing edge of the start signal. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to the shelf state. Power Start Output (N.C.) Output (N.O.) Power LED T T t<T t T Basic Operation Power T T Start Output 124 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Mode D -- Off-Delay (Trigger = Signal Off) a. Need continuous input power applied. b. Contacts change state immediately when start signal is applied. c. Timing is initiated by the trailing edge of the start signal. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to the shelf state. Power Start Output (N.C.) Output (N.O.) Power LED Basic Operation T t t<T Power T Start Output Mode E -- One-Shot (Trigger = Signal On) 700-HR52, -HRV, and -HRT6 a. Need continuous input power applied. b. Timing is initiated by the leading edge of the start signal. c. Contacts change state immediately when start signal is applied. d. At the end of the time period contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state. f. When the input power is removed contacts return to shelf state. Power Start Output (N.C.) Output (N.O.) Power LED T tT Mode E -- One-Shot (Trigger = Power On) 700-HRS, -HRP, and -HRT4 a. Need continuous input power applied. b. iming is initiated when the input power is applied. c. At the end of the time period contacts return to the shelf state. d. Relay timing is reset when input power is removed. Basic Operation t<T T Power Start Output T Power Basic Operation t<T Power T Timed Output (N.C.) Timed Output (N.O.) Power LED Output Mode G -- Watchdog Monitor (Trigger=Signal ON/OFF) a. Need continuous input power applied. b. Timing is initiated by the landing edge of the start signal. c. After the first timing cycle is complete the contacts change state and timing is initiated by the trailing edge of the start signal. d. At the end of the time period the contacts return to the shelf state. e. Relay timing is reset when additional start signals are applied while the relay is timing. f. When the power is removed contacts return to the shelf state. Relay and Timer Specifications Rockwell Automation Publication 700-TD552F-EN-P - January 2021 125 Relay and Timer Specifications Mode J -- Delayed One-Shot (Trigger = Power On) a. Need continuous input power applied. b. No start signal applied. c. Timing is initiated when input power is applied. d. Contacts change state after the timing for a fixed time of 1s +/-0.5s e. At the end of the 1 sec period the contacts return to the shelf state. f. When the input power is removed contacts return to the shelf state. T Power Output (N.C.) Output (N.O.) Power LED 1s ±0.5s Basic Operation T Power Output (N.O.) Power LED 1s ±0.5s Mode Star-Delta a. Need continuous input power applied. b. No start signal required. Timing is initiated when input power is applied. c. Star ouput contact changes state when input power is applied. d. After timing is complete star output contact returns to the shelf state then both the star & delta contacts remain in shelf states until transfer time setting is complete. e. Delta output contact changes state after transfer time is complete. f. Instantaneous contact changes state when input power is applied. g. All contacts return to the shelf state when input power is removed. Power Output (N.C.) Output (N.O.) Output 8-5, LED Output 8-6, LED t1 t2 Power Instantaneous Output Output 8-5, LED Output 8-6, LED Basic Operation t1 t2 Mode True Off-Delay (Trigger = Power Off) a. Continuous input power is NOT required. b. No start signal applied. c. Contacts change state immediately when input power is applied. d. Timing starts when input power is removed. e. At the end of the time period contacts return to the shelf state. f. Relay timing is reset when input power is reapplied while the relay is timing. Contacts remain in energized state. Power Output (N.C.) Output (N.O.) Relay On LED t<T T t T Basic Operation T Power Output Relay On LED 126 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700-HR Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 127 Relay and Timer Specifications 700-HT Plug-in Timing Relay · Timing Relay (On-Delay or Off-Delay) · Rugged Pin Style Socket Mounting · 10 A, DPDT Contact Ratings · 0.1 s...30 min Fixed Timing Relay · 0.1 s...3 min Single Adjustable Timing Relay · Single or Fixed Timing Single Range Timing Relay with Pin Style Terminations 700 HT 2 a b c Catalog Number Explanation - 700-HT Relays a Bulletin Number b Type of Relay c Operating Mode d Number of Poles HT - 1On-delay 700 Tube Base Adjustable 2Off-delay Timing Relay 2 - 2PDT 2 A A2 d e f e Timing Range A 0.1...10 s B 1.0...100 s C 0.1...10 min D 1.0...100 min E 0.1...10 hr Operating Mode Wiring Diagrams U.S./Canada International f Coil Voltage U12 12V DC U24 24V AC/DC, 50/60 Hz U120 120V AC/DC, 50/60 Hz A2 240V AC, 50/60 Hz On-Delay Socket 700-HN125 or 700-HN100 700-HN100 Off-Delay 700-HT DPDT 2-Pole -- 2 Form C Contacts Socket 700-HN126 or 700-HN101 700-HN101 128 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Fixed Timing Relays 700-HTF Fixed Timing Relays feature a plug-in tube base. Construction is the same as the 700-HT relay except that the adjustment knob has been removed to help prevent unwanted tampering. The timing and output specifications are identical to those of the 700-HT relay. Setting time will be ±5% of the time ordered. 700 HTF 2 2 025 S A2 a b c d e f g Catalog Number Explanation - 700-HTF Relays a Bulletin Number b Type of Relay HTF- 700 Tube Base Fixed Timing Relay c Operating Mode 1On-delay 2Off-delay d Number of Poles 2 - 2PDT e Timing Range 001...999 The three digit code represents a numeric value with one decimal place. For example: code 001 is 0.1, code 025 is 2.5, and code 999 is 99.9 The acceptable range for each time unit is listed below: Seconds - 001...999 Minutes - 001...999 Hours - 001...100 f Timing Units S Seconds M Minutes H Hours g Coil Voltage U12 12V DC U24 24V AC/DC, 50/60 Hz U120 120V AC/DC, 50/60 Hz A2 240V AC, 50/60 Hz Socket and Retainer Clip Reference Relay Type Socket Cat. No. 700-HT12 700-HN100 700-HN125 700-HT22 700-HN101 700-HN126 (1) Design of these sockets holds the relays securely and does not require retainer clips. Retainer Clip Cat. No. 700-HN110 Not Required(1) 700-HN110 Not Required(1) Accessories - 700-HT Relays Description Pkg. Qty. Cat. No. Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Digital Timing Relays, -HT (On-Delay) 10 and -HRM, -HRC and -HV (Repeat Cycle) Timing Relays. Order ten or multiples of ten 700-HN100 Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC and -HV (Repeat Cycle) Timing Relays. Order must be for 10 sockets or multiples of 10. No retainer clip 10 required. 700-HN125 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 129 Relay and Timer Specifications Description Pkg. Qty. Cat. No. Screw Terminal Tube Base Sockets -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 11-pin for use with 3PDT 700-HA relays. 10 700-HN101 Screw Terminal Tube Base Sockets -- Panel or DIN Rail Mounting; Open Style Terminal Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required. 10 700-HN126 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with 700-HT Timing Relays(1)Secures relay in socket. Order must be for 10 clips or multiples of 10. 10 700-HN110 Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank 10 tags. Tags are peel-off with sticky backing for easy placement on relays. 700-N40 Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10 easy placement on relays. 700-N41 (1) Refer to 700-HT Timing Relay, Socket, and Retainer Clip Reference Chart. 130 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-HT Pilot Duty Rating (1) Rated Thermal Current (Ith) Rated Insulation Voltage (Ui) Inductive Cat. No. 700-HT... Cat. No. 700-HTF... Electrical Ratings NEMA B300 10 A 250V IEC, 300V UL/CSA Make Break HP Make Break HP Contacts 120V AC 240V AC Resistive 28V DC Permissible Coil Voltage Variation Power Consumption ±10% 24V AC AC 120V AC 240V AC DC Pole-to-Pole, same circuit (VRMS) Dielectric Withstand Voltage Pole-to-Pole, different circuits (VRMS) Contact-to-Coil (VRMS) Electrical Life Operations Switching Frequency Operations Coil Voltages Degree of Protection Mechanical Life Operations Switching Frequency Operations Timing Duty Cycle Repeat Accuracy (constant voltage and temperature) Repeat Accuracy (variable voltage and temperature) Fixed Time Setting Accuracy Scale Tolerance Reset Time High End of Range Low End of Range ON Delay OFF Delay 30 A 3 A 1/2 N.O. 1/3 N.C 30 A 3 A 1/3 15 A 1.5 A 1/2 N.O. 1/3 N.C 15 A 1.5 A 1/2 10 A 10 A -- 10 A 10 A -- 85...110% of Nominal Voltage at 50 Hz 85...110% of Nominal Voltage at 60 Hz 80...110% of Nominal Voltage at DC 2 VA 4 VA 4 VA 1.3 W Design Specification/Test Requirements 1000V AC Mechanical -- +5% -50% 2000V AC 2000V AC 100,000 minimum 1800/hr See product selection Open Type (Guarded Terminal Sockets) 10 x 106 18,000/hr Continuous ±2% (Time Delay: 0.1...2 s) ±1% (Time Delay: >2 s) ±10% 100 ms 40 ms ±5% (Time Delay: 0.1...2 s) ±1% (Time Delay: >2 s) -- -- Rockwell Automation Publication 700-TD552F-EN-P - January 2021 131 Relay and Timer Specifications Environmental Temperature Altitude Construction Insulating Material Enclosure Contact Material Terminal Markings on Socket Operating Storage Sockets Certifications Standards (1) See NEMA Ratings and Test Values on page 5. Cat. No. 700-HT... Cat. No. 700-HTF... 28...+65 °C (50 °C max., 240V AC coil) (18...+149 °F) (122 °F max., 240V AC coil) 55...+85 °C (67...+185 °F) 2000 m (6560 ft) Molded High Dielectric Material Impact Resistant Dust Cover Silver Cadmium Oxide In accordance with EN50 005 8- or 11-Pin Socket (On = 8, Off = 11) 700-HN100, -HN125 700-HN101, -HN126 CSA Certified, File 223833, UL Recognized, File E3125 Guide NLDX 2,UL Listed,whe used with 700-HN100, 700-HN101, 700-HN125, and 700-HN126 Sockets, File No. E3125 Guide NLDX, CE Marked EN 61812-1, CSA 22.2 No. 14, UL 508 Trigger Signal Cat. Nos. 700-HT Contact closure provides signal to timer. A low energy signal is generated by the 700-HT timing relay. For optimum reliability, use contacts designed for low energy switching (10V, 1 mA) (Bul. 800F-X__V, 800T-X__V). No external voltage should be connected to the contact signal. Timing Diagrams - 700-HT Relays ON Delay OFF Delay 132 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 700-HV Timing Relay · Repeat Cycle Timing Relay · 10 A Contact Rating · DPDT · Pin Style Terminals · 0.1 s...30 min. · Repeat Cycle Adjustable Timing · Two Timing Adjustments T1 T2 Repeat Cycle Timing Relays with Pin Style Terminations with 2 Adjustments (T1 T2) Operating Mode Relay and Timer Specifications Wiring Diagrams U.S./Canada International Repeat Cycle 700-HV Repeat Cycle Timing Relay DPDT 2-Pole -- 2 Form C Contacts Socket 700-HN125 or 700-HN100 700-HN100 700 HV 3 2 A A A2 a b c d e f g Catalog Number Explanation - 700-HV Relays a Bulletin Number b Type of Relay c Operating Mode d Number of Poles e Timing Range OFF Time Code OFF Time -- Type HV 3 Power ON A 0.1...10 s Repeat Cycle, B 1.0...100 s 700 HV Tube Base Repeat OFF Start Cycle Timing Relay (Repeat Cycle, 2 - 2PDT C 0.1...10 min OFF/ON D 1.0...100 min Delay) E 0.1...10 hr f Timing Range ON Time Code ON Time -- Type HV A 0.1...10 s B 1.0...100 s C 0.1...10 min D 1.0...100 min E 0.1...10 hr g Coil Voltage U12 12V DC U24 24V AC/DC, 50/60 Hz U120 120V AC/DC, 50/60 Hz A2 240V AC, 50/60 Hz Socket and Retainer Clip Reference Relay Type Socket Cat. No. Retainer Clip Cat. No. 700-HV 700-HN100 700-HN125 700-HN110 Not Required(1) (1) Design of these sockets holds the relays securely and does not require retainer clips. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 133 Relay and Timer Specifications Accessories - 700-HV Relays Photo Description Pkg. Qty. Cat. No. Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Digital Timing Relays, -HT (On-Delay) and - 10 HRM, -NRC and -HV (Repeat Cycle) Timing Relays. Order ten or multiples of ten 700-HN100 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Open Style Construction. 8Pin for use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC and -HV (Repeat Cycle) Timing 10 Relays. Order must be for 10 sockets or multiples of 10. No retainer clip required. Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are 10 peel-off with sticky backing for easy placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10 relays. 700-HN125 700-N40 700-N41 134 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-HV Relays Pilot Duty Rating Rated Thermal Current (Ith) Rated Insulation Voltage (Ui) Inductive Cat. No. 700-HV... Electrical Ratings NEMA B300 10 A 250V IEC, 300V UL/CSA Make Break Hp Contacts Permissible Coil Voltage Variation Power Consumption AC ±10% DC Dielectric Withstand Voltage Electrical Life Operations Switching Frequency Operations Coil Voltages Degree of Protection Mechanical Life Operations Switching Frequency Operations Timing Repeat Accuracy (constant voltage and temperature) Repeat Accuracy (variable voltage and temperature) Scale Tolerance Reset Time Temperature Altitude Construction Insulating Material Enclosure 120V AC 30 A 3 A 1/2 N.O. 1/3 N.C. 240V AC 15 A 1.5 A 1/2 N.O. 1/3 N.C. Resistive 28V DC 10 A 10 A -- 85...110 of Nominal Voltage at 50 Hz 85...110 of Nominal Voltage at 60 Hz 80...110 of Nominal Voltage at DC 24V AC 2 VA 120V AC 4 VA 240V AC 4 VA 1.3 W Design Specification/Test Requirements Pole-to-Pole, same circuit (VRMS) 1000V AC Pole-to-Pole, different circuits (VRMS) 2000V AC Contact-to-Coil (VRMS) 2000V AC 100,000 minimum 1800/hr See product selection Mechanical Open Type (Guarded Terminal Sockets) 10 x 106 18,000/hr Duty Cycle Continuous ±2% (Time Delay: 0.1...2 s) ±1% (Time Delay: >2 s) ±10% High End of Range Low End of Range Operating Storage Environmental +5% -50% 100 ms 28...+65 °C (50 °C max., 240V AC coil) (18...+149 °F) (122 °F max., 240V AC coil) 55...+85 °C (67...+185 °F) 2000 m (6560 ft.) Molded High Dielectric Material Impact Resistant Dust Cover Rockwell Automation Publication 700-TD552F-EN-P - January 2021 135 Relay and Timer Specifications Contact Material Terminal Markings on Socket Sockets Certifications Standards Timing Diagram- 700-HV Relays Silver Cadmium Oxide In accordance with EN50 005 8-Pin Socket Cat. No. 700-HN100, -HN125 CSA Certified, File 223833; UL Recognized, File E3125; Guide NLDX 2; cULus Listed when used with 700-HN100 and 700HN125 sockets; CE Marked EN 61812; CSA 22.2 No. 14; UL 508 Dimensions - 700-HV Relays Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes. 700-HV Timing Relay Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes Cat. No. 199-DR1 199-DR4 A B C D Approx. Shipping Wt. 35 27 7.5 1.02 1.85 kg (1-3/8) (1-1/16) (19/64) (1/64) (4.07 lbs.) (10/pkg) 35 27 15 2.3 3.68 kg (1-3/8) (1-1/16) (19/32) (3/32) (8 lbs.) (5/pkg) 136 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Cat. No. 700-HN100 Panel Mounting Double Wire--2 x 2.5mm2 (#2-14 AWG...#2-20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) - Torque: 0.8 N·m (7 ib·in) Cat. No. 700-HN125 Wire Size: 2 x 2.5 mm2 Single Wire--Up to #12 AWG Double Wire--2 x 2.5mm2 (#2-14 AWG...#2-20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in) - Torque: 0.8 N·m (7 ib·in) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 137 Relay and Timer Specifications 700-HX Multi-Function Digital Timing Relay · Digital timing relay with LCD display · Socket- or panel-mounted (NEMA 4X/IP66) · 5A, B300, SPDT contact ratings · 10 Functions or modes · Environmentally friendly -- flash memory, no battery Photo Operating Mode Timing Range A mode: Signal ON-Delay 1 A-1 mode: Signal ON-Delay 2 A-2 mode: Power ON-Delay 1 A-3 mode: Power On-Delay 2 B mode: Repeat Cycle 1 B-1 mode: Repeat Cycle 2 D mode: Signal OFF-delay E mode: One Shot F mode: Cumulative Z mode: On/Off duty adjustable repeat cycle S mode:stop watch toff: Flicker OFF start 1 ton: Flicker ON start 1 toff-1: Flicker OFF start 2 ton-1: Flicker ON start 2 0.000...9.999 s 0.000...99.99 s 0.000...999.9 s 0.000...9999 s 0.000...99 min 59 s 0.000...999.9 min 0.000...9999 min 0.000...99 hr 59 min 0.000...999.9 hr 0.000...9999 hr Socket Type 700-HN100 700-HN125 Contact Output No. of Pins SPDT 8 Input Voltage Cat. No. 100...240V AC 700-HX86SA17 24V AC 12...24V DC 700-HX86SU24 Socket and Retainer Clip Reference Timer Type Socket Cat. No. Retainer Clip Cat. No. 700-HX 700-HN100 700-HN108 700-HN131 Not Required (1) 700-HN125 Not Required (1) Design of socket holds the relay securely and does not require retainer clips. Accessories - 700-HX Relays Photo Description Pkg. Quantity Cat. No. Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin for use with 700-HX Timing Relays. Order ten or multiples of ten 10 700-HN100 Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use with 700-HX Timing Relays. Order must be for 10 sockets or 10 multiples of 10. No retainer clip required. DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 700-HN125 199-DR1 138 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Photo Description Specialty Socket 8-pin backwired socket with solder terminals. For use with 700-HX Timing Relays. Relay and Timer Specifications Pkg. Quantity Cat. No. 10 700-HN108 Retainer Clip for Cat. Nos. 700-HN100 Sockets with all 700-HX Timing Relays Secures timer in socket. 10 Note: Not required for installation 700-HN131 Frame Adapter For flush or door mounting of all 700-HR and -HX timers. 1 700-HN130 Protective Cover Helps prevent tampering of timing and mode settings. Provides a degree of protection against water and dirt from entering the front of the relay. For use with all 700-HR and -HX timing 1 relays. 700-HN132 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 139 Relay and Timer Specifications General Timer Functions- 700-HX Relays Display Section Operation Key 1. Key Protect Indicator (orange) 4 8. Mode Key 2. Control Output Indicator (orange) 1 3. Reset Indicator (orange) 2 3 8 4. Present Value Display (Main display) 9 (Character height: 12 mm, red *) 5 (Changes modes and setting items) 6 7 9. Reset Key 10 (Resets present value and output) 11 10. Up Keys 1 to 4 * Characters on models with screw terminals Front View 11. Down Keys 1 to 4 can be switched between red, green, and orange. 12 5. Time Unit Indicators Switches (Color is same as present value display.) (If the time range is 0 min, 0 h, 0.0 h, or 0 h 0 min, these indicators flash to indicate timing operation.) 12. Key-protect Switch (Default setting) OFF (Disabled) ON (Enabled) 6. Set Value Display (Sub-display) (Character height: 6 mm, green) 7. Set Value 1, 2 Indicator (green) Character Size for Present Value Display Character Size for Set Value Display 12 mm 6 mm 140 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Specifications - 700-HX Relays Attribute Pilot Duty Rating Rated supply voltage Operating voltage range Power consumption Inrush Current Make Break Hp at 120V AC Hp at 240V AC 100...240V AC 24V AC/12...24V DC 100...240V AC 24V AC/12...24V DC 120V AC 240V AC 120V AC 240V AC Mounting Method Display Digits Timer Inputs Control output External Power Supply Key Protect Memory Backup Time ranges Timer modes Output modes Input signals Input method Start, reset, gate Power reset Accuracy of Operating Time and Setting Error (1) (1) The values are based on the set value. (2) The value is applied for a minimum pulse width of 1 ms. Relay and Timer Specifications 700-HX Electrical Ratings NEMA B300 100 to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible ripple: 20%(p-p) max.) 85...110% of rated supply voltage 4.3VA 3.4VA/1.7 W 3 A 5 A 30 A 15 A 3 A 1.5 A 1/4 Hp 1/3 Hp Mechanical Flush mounting, surface mounting, DIN mounting Seven-segment, negative transmissive LCD; Present value (red, 12 mm high characters); Set value (green, 6 mm high characters) Four digits 0.000...9.999 s, 0.00...99.99 s, 0.0...999.9 s, 0...9999 s, 0 min 00 s...99 min 59 s, 0.0...999.9 min, 0 hr 00 min...99 hr 59 min, 0.0 hr...999.9 hr, 0 hr...9999 hr Elapsed time (Up), remaining time (Down), selectable A, A-1, A-2, A-3, B, B-1, D, E, F, Z, S, tOFF, tON, tOFF-1, or tON-1 Start, reset No-voltage input via:NPN transistor or switching of contact Minimum input signal width: 1 or 20 ms (selectable) Minimum power-opening time: 0.5 s (Except for A-3, B-1, and F mode) SPDT contact output: 5 A at 250V AC, resistive load (cosine=1) Minimum applied load: 10 mA at 5 V DC (failure level: P, reference value) No Yes EEP-ROM (overwritten 100 000 times min), which can store data for 10 years min. Power-ON start: +-0.01% +-50 ms max. (1)to be rated against set value Signal start: +- 0.005% +-30 ms max. (1)to be rated against set value Signal start at transistor output model: +- 0.005% +-3 ms max. (2) If the set value is within the sensor waiting time (250 ms max.) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 141 Relay and Timer Specifications Attribute 700-HX Environmental Installation environment Setup category II, pollution degree 2 (as per IEC61010-1) Ambient temperature -10...+55 °C (14...141 °F ), Avoid freezing or condensation Ambient humidity 25...85 % Storage temperature -25...+65 °C (-13...+149 °F ), Avoid freezing or condensation Altitude, max Insulation Resistance Characteristics (1) 2,000 m 100 m min.(at500VDC) Dielectric Strength 2000V AC, 50/60Hz for 1 min between current-carrying terminals and non-current- carrying metal parts (1000V AC for 24V AC/12 to 24V DC type), 1000 VAC, 50/60 Hz for 1 min between non- continuous contacts Noise Immunity ±1.5 kV (between power terminals) for 100 to 240 VAC, ±480V for 24VAC/12 to 24VDC, and ±600V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/ 1 s, 1-ns rise) Static Immunity ±8 kV (malfunction), ±15 kV (destruction) Vibration Resistance Shock Resistance Malfunction Malfunction 10...55 Hz with 0.35 mm single amplitude each in three directions for 10 min 98 m/s2 (approx. 10 G) each in three directions Life Expectancy Mechanical Electrical 10 million operations min. (under no load at 18 000 operation/hr) 100 000 operations min. (5 A at 250V AC, resistive load at 1800 operation/hr) (EMI) EN61812-1 Emission Enclosure: EN55011 Group1 class A Emission AC mains: EMC (EMS) EN55011 Group1 class A EN61812-1 Immunity ESD: EN61000-4-2: 4 kV contact discharge (level2) 8 kV air discharge (level3) Enclosure Ratings Immunity RF-interference: EN61000-4-3: 10 V/m Panel surface:IP66 and NEMA Type 4 (indoors) (2) Weight Approx. 100 g Certifications CE Certified; cURus (File No. E14843, Guide NRNTZ/NRNT8), C-Tick Marked Standards EN61010-1, EN 61326, VDE0106/P 100, CSA C22.2 No. 14, UL 508 (1) More information in the 700-HX User Manual, publication 700-UM002. (2) An attached waterproof packing is necessary to ensure IP66 waterproofing between the 700-HX and installation pan. 142 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Timing Charts- 700-HX Relays One-Shot One-shot outputs can be set to Sustained Output 0.1s, 0.5 s, 1 s, 5 s, 10 s, or 20 s. Power Start signal Gate* Output Mode A Mode: Signal ON-Delay (Timer resets when power comes ON.) Timing starts when the start signal goes ON. While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. The control output is controlled using a sustained or one-shot time period. Basic Operation Reset t Control output Set value UP Timing 0 diagram Set value DOWN 0 t t Power Start Signa**l Input Timing Output *Output is instantaneous when setting is 0. ** Start signal input is enabled during timing. Power Start signal Gate* Reset Control output Set value UP Timing 0 diagram Set value DOWN 0 Power Start signal Gate * Reset Output Mode A-1: Signal ON-Delay 2 (Timer resets when power comes ON.) Timing starts when the reset input goes ON and is reset when the start signal goes OFF. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. The control output is controlled using a sustained or one-shot time period. Basic Operation Power Start Signal Input Timing Output *Output is instantaneous when setting is 0. Output Mode A-2: Power ON Delay 1 (Timer resets when power comes ON) Timing starts when the reset input goes OFF. The start signal disables the timing function (i.e., same function as the gate input). The control output is controlled using a sustained or one-shot time period. Basic Operation Control output Set value UP Timing 0 diagram Set value DOWN 0 Power Timing Output *Output is instantaneous when setting is 0. Output Mode A-3 Power ON Delay 2 (Timer does not reset when power comes ON) Power Start signal Gate * Reset Timing starts when the reset input goes OFF. The start signal disables the timing function (i.e., same function as the gate input). The control output is controlled using a sustained or one-shot time period. Basic Operation Control output Set value UP Timing 0 diagram Set value DOWN 0 Power Output Timing Sustained *Output is instantaneous when setting is 0. Gate not included on any mode of this relay. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 143 Relay and Timer Specifications Sustained Output Power Start signal Gate* Reset Control output Set value UP Timing 0 diagram Set value DOWN 0 One-Shot Output Power Start Signal Gate* Reset Control Output Set Value Timing UP 0 Diagram Set Value DOWN 0 Output Mode B: Repeat Cycle (Timer resets when power comes ON.) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Basic Operation Power Start Sign*a*l Input Timing Timing Timing Timing Output * Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled diring timing. Timing starts when the start signal goes ON. The control output is turned ON when time is up. While the start signal is ON, the timer starts when the power cones ON or when the reset input goes OFF. Basic Operation Power Start Signa**l Input Output Timing Timing Timing Timing * Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. Sustained Output Power Start signal Gate* Reset Control output Set value UP Timing 0 diagram Set value DOWN 0 One-Shot Output Power Start signal Gate* Reset Control output Set value UP Timing 0 diagram Set value DOWN 0 Output Mode B-1: Repeat Cycle 2 (Timer does not reset when power comes ON) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at the start). While the start signal is ON, the timer starts when the power comes ON or when the rest input goes OFF. Basic Operation Power Start Signa**l Input Timing Sustained Timing Output * Normal output operation will not be possible if the set time is too short Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during. Timing starts when the start signal goes ON. The control output comes ON when time is up. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Basic Operation Power Start Sign*a*l Input Timing Timing Output Sustaining * Normal outout operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. Gate not included on any mode of this relay. 144 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Power Start signal Gate* Reset Control output Set value UP Timing 0 diagram Set value DOWN 0 Power Start signal Gate* Reset Control output Set value UP Timing 0 diagram Set value DOWN 0 Output Mode D: Signal OFF-Delay (Timer resets when power comes ON.) The control output is ON when the start signal is ON (except when the power is OFF or the reset is ON). The timer is reset when the time is up. Basic Operation Power Start Signa**l Input Timing Output * Output functions only during start signal input when setting is 0. ** Start signal input is enabled during timing. Output Mode E: Interval (Timer resets when power comes ON.) Timing starts when the start signal comes ON. The control output is reset when time is up. While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. Basic Operation Power Start Signa**l Input Timing Output * Output is disabled when the setting is 0. ** Start signal input is enabled during timing. Output Mode F: Cumulative (Timer does not reset when power comes ON) Start signal enables timing (timing is stopped when the start signal is OFF or when the power is OFF). A sustained control output is used. Basic Operation Gate not included on any mode of this relay. Power Start Signal Input Output Timing Timing Sustained *Output is instantaneous when setting is 0. Z Mode Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (%) set value. The set value shows the ON duty (%) and can be set to a value between 0 and 100 (%). When the cycle time is 0, the output will always be OFF. When the cycle time is not 0 and when ON duty has been set to 0 (%), the output will always be OFF. When ON duty has been set to 100 (%), the output will always be ON. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 145 Relay and Timer Specifications Power Start signal * Gate Z mode: ON/OFF-duty Adjustable Repeat Cycle Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. Basic Operation Power Reset Control Output Cycle time Timing diagram ON duty setting (%) ON time UP 0 Cycle time ON duty setting (%) ON time DOWN 0 Start sign*a*l input Timing (cycle time) Timing (cycle time) Timing ON duty (%) Timing ON duty (%) Output * Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is enabled during timing. Output Mode S: Stop Watch (Timer resets when power comes ON) Timing diagram Power Start signal Gate/Reset 9999 Set time UP 0 Set time DOWN 0 Output Sustained Output Power Start signal * Gate Reset Control Output OFF Time UP ON Time Timing 0 diagram OFF Time DOWN ON Time 0 Gate not included on any mode of this Relay. The signal starts and stops timing. The display is held and timing is continued if the reset or gate input is received during timing operation. The timer resets if the reset or gate input is received when the timing operation is stopped. Basic Operation Power Start signal input Gate/Reset Timing Display (for elapsed time) * * RST flashes Note: Output is instantaneous when setting is 0. Output Mode T OFF: Twin Timer OFF start Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. Basic Operation Power Start Signa**l Input Output Timing Timing Timing Timing OFF ON OFF ON * Normal output operation will not be possible if the ON/OFF set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. 146 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Sustained Output Power Start signal * Gate Reset Control Output OFF Time UP ON Time Timing 0 diagram OFF Time DOWN ON Time 0 Power Start signal Gate Reset Control output OFF time UP ON time 0 OFF time DOWN ON time 0 Timing diagram Relay and Timer Specifications Output Mode T ON: Twin Timer ON start Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. Basic Operation Power Start Signa**l Input Output Timing Timing Timing Timing ON OFF ON OFF * Normal output operation will not be possible if the ON/OFF set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. Output Mode TOFF-1: Flicker OFF start 2 (Timer does not reset when power comes ON) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Basic Operation Power Start signa*l input Timing OFF Timing ON Timing OFF a b Output (a + b = ON time) * Start signal input is disabled during timing. Note: Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). Output Mode TON-1: Flicker ON start 2 (Timer does not reset when power comes ON) Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Basic Operation Power Start signa*l input Timing ON Timing OFF Timing ON a b Output (a + b = OFF time) * Start signal input is disabled during timing. Note: Normal output operation will not be possible if the set time is too short. Gate not included on any mode of this Relay. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 147 Relay and Timer Specifications Dimensions- 700-HX Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 48×48 7.5 14.3 63.7 44.8×44.8 60 min. 45 +0.6 -0 45 +0.6 -0 60 min. 15 min. Cat. No. 700-HX... Panel Cutout 5.2 (13/64) Terminal Arrangement 50 (1-63/64) 6.2 (15/64) 12.5 (1/2) 1000 (39-3/8) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes 1.0 (0.04) 35.0 (1.38) 7.5 (0.3) 27.0 (1.06) Signal Reset Internal circuit 4 3 2 1 0V 5 6 7 8 () (+) Cat. No. 700-HX... 148 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 NEMA Industrial Relays Product Overview Relay and Timer Specifications Bulletin No. Type 700-P Heavy-duty control relay Features · Convertible contacts · Up to 600V AC & DC · Very long life · Timer & latch options · Mechanically linked Contact Form Contact Type Contact Material Electrical Max. Current AC Resistive Min. load Coil Voltage Coil Voltage Pickup Dielectric Withstand Reference Electric Service Life (cycles) Certifications Sockets Product Selection 2...12 poles, double break Bifurcated double break Bifurcated silver nickel 10 A 10V, 50 mA 1 mA, 5V with 700-CPR 24...600V AC 6...600V DC 85...110% AC coils, 80...110% DC coils 2640V 10 million at 10 A 120V AC cULus, CE DIN Rail, relay rail, or panel mount 151 700S-P Heavy-duty control relay · Convertible contacts · Up to 600V AC & DC · Very long life · Timer & latch options · Mechanically linked 2...12 poles, double break Bifurcated double break Bifurcated silver nickel 10 A 10V, 50 mA 1 mA, 5V with 700-CPR 24...600V AC 6...600V DC 85...110% AC coils, 80...110% DC coils 2640V 10 million at 10 A 120V AC cULus, CE DIN Rail, relay rail, or panel mount 151 700-N Industrial Relay · Contact cartridges convertible from N.O. to N.C. and vice versa · NEMA A300 AC · 24...250V AC coils · Pneumatic timing unit · Solid-state timing unit · Overlap contacts · Logic reed contacts 2- or 4-poles -- Silver 10 A -- -- -- -- -- UL, CSA, CE -- 172 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 149 Relay and Timer Specifications Product Overview Bulletin No. Type Features Contact Form Contact Type Contact Material Electrical Max. Current AC Resistive Min. load Coil Voltage Coil Voltage Pickup Dielectric Withstand Reference Electric Service Life (cycles) Certifications Sockets Timing Relay Information Control Outputs: Time Limit Instantaneous Timing Operation Modes: Time Range Supply Voltage Product Selection 700-R Sealed Switch · Hazardous location ratings · Long life in dirty environment · Timer and latch options · Switch 600V AC, 300V DC 2...8 Poles Sealed Switch Sealed Switch 5 A 1 mA, 5V 24...240V AC 24...250V DC 85...110% AC Coils 80...110% DC Coils 2640V 1.5 million at 5 A 120V AC UL, CSA, CE Panel or rail mount -- -- -- -- 176 700-RTC Solid-state Timing Relay · Timed and instantaneous contacts. · Sealed contacts for harsh environments and hazardous locations. -- -- -- -- -- -- -- -- -- -- -- -- Four output contacts On-Delay Off-Delay 0.05 s...64 min 24V AC 110...120V AC 220...240V AC 24V DC 120V DC 240V DC 181 150 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-P Industrial Relays 700-P -- Direct DriveTM Convertible Contact Cartridge Relays · NEMA and IEC ratings · 600V maximum AC/DC · Accessories for field installation: contact cartridges, adder decks, time delay, latching, surge suppressors, mounting strip · Contact Ratings: (10 A) 700-CP1, (20 A) 700-CPM, (35 A) 700-CPH, (Low Power) 700-CPR · For machine tool and other heavy-duty applications · Can accommodate ring tongue terminals · Integral DIN Rail mount on AC relays · Finger-safe protection standard · Factory supplied standard at 120V AC and 24V DC - user configurable for field assembly · Blank relays are available in all coil voltages for field custom configuration · Contact cartridge is convertible from N.O. to N.C. by simply turning cartridge over. The 700/700DC-P family of Direct Drive Industrial Relays offers switching solutions ranging from 200 mA in Low Energy Circuits to 35 A in Heavy Duty Circuits. All of the contacts can easily be changed from the standard N.O. to N.C. configuration. The relays can be accessorized to meet the application needs with the use of time delayed contacts, mechanical latches and NEMA enclosures. All devices are available in the most popular AC and DC control voltages. Combining different cartridges into one relay can yield a custom-tailored application solution. Relays are available without contact cartridges in all of the available AC and DC coil voltages for maximum flexibility. 700/700DC-P relays use standard (10 A) contact cartridges with a double-break and bifurcated design. Bifurcation provides excellent contact reliability and low-contact bounce, while the double-break contact design reduces the possibility of contacts welding and enhances the relay's ability to break DC circuits. These relays can be configured with a maximum of 12 contacts (only 8 may be N.C.). A Modular Approach to Control Circuit Solutions The 700-P AC control relay is factory assembled with a standard 10 A contact cartridges with all contacts as N.O.in either 2, 4, 8, or 12 pole configurations with a 120 volt operating coil. Four pole relays are also available at 240 and 480 VAC and can have up to eight contacts added by using adder decks. The 700DC-P control relay is factory assembled with a standard 10 A contact cartridges with all contacts as N.O. in either 4 or 8 poles with a 24 volt operating coil. The 4 pole is also available with a 120 VDC operating coil. For control relays that require different contact ratings or control voltages we offer a modular design that are easily field configurable. A base blank relay (either AC or DC control), a variety of contact kits, adder decks, and operating coils can be used to make an infinite number of custom control relay solutions. · Master Control 700-PMCKIT master control cartridges provide (20 A) switching capability with large single-contact pads on each side of the spanner for twice the current rating to control heavy loads and provide for master control of a system. The cartridge also has the same double-break design as the standard 700-P relay contact cartridge. Relays can be configured with up to a maximum of 12 contacts (only 8 may be N.C.). Time delay and latching attachments are compatible with master cartridges. · Heavy Duty Control 700-PHDKIT contact cartridges provide (35 A) switching capability through tandem contact cartridges. A jumper allows two (20 A) master contact cartridges to be connected in parallel. A maximum of six poles can be configured in a relay, only four of which can be normally closed. Time delay and latch attachments are available. · Low Energy Control Logic Reed 700-PLRKIT contact cartridges provide switching to 200 mA @ 30 VDC. These contacts are matched with standard control (10 A) contact cartridges for low energy switching applications. · Overlapping Contact 700-POLKIT contact cartridges provide (10 A) switching capabilities with the same rating as the standard contact. These cartridge used in pairs operate with the N.O. contact closing before the N.C. contact opens on pick-up and vice versa on the dropout. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 151 Relay and Timer Specifications AC-Operated Relays - In-stock Contact Configurations Photo Contacts N.O.(1) Contact Arrangement and Markings 0 4-Pole Relay Open Type, DIN Rail, or Relay Rail Mount (700-MP) 120V AC 240V AC 480V AC 700-P000A1 -- -- 2 4-Pole Relay 4-Pole 4 Relay 700-P200A1 -- -- 700-P400A1 700-P400A2 700-P400A4 8 8-Pole Relay 700-P800A1 -- -- 12 12-Pole Relay 700-P1200A1 -- -- (1) Factory assembled N.O. contacts can be easily to N.C. in the field. DC-Operated Relays - In-stock Contact Configurations Photo Contacts N.O. (1) Contact Arrangement and Markings 4-Pole 0 Relay Open Type Relay Rail Mount (2) 24V DC 120V DC Cat. No. Cat. No. 700DC-P000Z24 -- 4-Pole 4 Relay 700DC-P400Z24 700DC-P400Z1 8 (1) Factory assembled N.O. contacts can be easily to N.C. in the field. (2) For DIN Rail mounting, order Cat. No. 700-DRA. 8-Pole Relay 700DC-P800Z24 -- 152 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Base Blank Relay - Factory Assembled Photo Relay and Timer Specifications Type of Control Circuit Cat. No. AC 700-P000 DC 700DC-P000 AC Coil Voltage Code Hz 24 50 -- 60 A24 DC Coil Voltage Code 24 Z24 110 A1 -- 48 Z48 115-120 -- A1 200-208 -- A20 230-240 -- A2 72 115-125 Z72 Z1 277 460-480 575-600 -- -- -- A27 A4 A6 230-250 Z2 575-600 Z6 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 153 Relay and Timer Specifications Master (20 A) and Heavy Duty (35 A) Contact Cartridge Options Follow this process to order a relay that utilizes: 20 A master contact cartridges or 35 A heavy duty contact cartridges. Base Blank Relay + Cartridge Kit + Adder Decks Base Blank Relay Type of Control Circuit AC + Coil Cat. No. 700-P000A1 DC 700DC-P000Z24 + Contact Cartridge Kits Photo Description Contents Master Contact Cartridge AC Rating Twice NEMA A600 DC Rating NEMA N150 P600 4 Master Cartridges (Cat. No. 700-CPM) Continuous Carrying Current [A] Cat. No. 20 700-PMCKIT Heavy Duty Contact Kit 4 Master Cartridges and two sets of jumper terminals, rating label (makes two 35 A poles) 35 700-PHDKIT + Adder Decks Do you have more than four circuits or more than two 35 A circuits in the relay? Device Description Adder Decks Required Cat. No. 8 Pole Device 700-PB00 12 Pole Device 700-PB00 700-PC00 (Qty 1 of each) Additional Cartridge Kits Required 1 additional kit 2 additional kits EXAMPLE Heavy Duty circuit (35 A) application that requires 4 circuits and 240 AC control circuit: · Base Unit: Cat. No. 700-P000A1 · Cartridge Kits: Cat. No. 700-PHDKIT - Qty 2 (Each kit makes two circuits) · Adder Deck: Cat. No. 700-PB00 · Coil: Cat. No. PA254 IMPORTANT If required, see Operating Coils for coil selection. 154 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Logic Reed and Overlapping Contact Cartridge Option Follow this process to order a relay that utilizes: low energy contact cartridges or overlapping late make or late break cartridges. Base Blank Relay + Cartridge Kit + Adder Decks + Coil Base Blank Relay Type of Control Circuit AC Cat. No. 700-P000A1 DC 700DC-P000Z24 + Contact Cartridge Kits Photo Description Contents Logic Reed Cartridge for Low Energy Circuits 150V AC 500 mA 25 VA Max. 30V DC 200 mA 6W Max. 2 Logic Reed Cartridges (Cat. No. 700-CPR) 2 Standard Cartridges (Cat. No. 700-CP1) Overlap Contact Cartridges Overlapping Used in pairs. N.O. contact closes before N.C. contact opens on pick-up and vice versa on drop-out. 4 Overlapping Cartridges (Cat. No. 700-CP11Z) + Adder Decks Do you have more than four circuits or more than two 35 A circuits in the relay? Device Description Adder Decks Required Cat. No. 8 Pole Device 700-PB00 12 Pole Device 700-PB00 700-PC00 (Qty 1 of each) Continuous Carrying Current [A] 500 mA 150V AC 200 mA 30V DC 10 Cat. No. 700-PLRKIT 10 700-POLKIT Additional Cartridge Kits Required 1 additional kit 2 additional kits EXAMPLE Logic Reed and Overlapping Contact Cartridge Option: · Low Voltage Circuit 24V DC less than 200 mA · Base Unit: Cat. No. 700-P000A1 · Cartridge Kits: Cat. No. 700-PLRKIT - Qty 1 · Coil: Cat. No. PA254 IMPORTANT If required, see Operating Coils for coil selection. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 155 Relay and Timer Specifications Accessories - 700-P Relays Adder Decks Photo Description No. of N.O. Contacts Continuous Carrying Current [A] Arrangement Second Deck (0-pole) 0 -- Second Deck (4-pole) 4 10 Third Deck (0-pole) 0 0 Third Deck (4-pole) 4 10 Cat. No. 700-PB00 700-PB40 700-PC00 700-PC40 156 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Operating Coils Bulletin 700-P Relays -- Bulletin 700-PLL-PKLL Mechanical Latch Attachments Coil Volts(2) 24 48 72 110 (3) Bulletin 700-P, 2...12-pole, AC control Bulletin 700-PLLPKLL AC Mechanical Latch Attachment 60 Hz PA013 -- -- -- 50 Hz PA407 -- -- PA236 60 Hz PL013 -- -- -- 50 Hz PL407 -- -- PL236 DC PM714 PM724 PM730 -- Bulletin 700DC-P 2...12-pole, DC control -- PD714 PD724 PD730 PD733 (100...110) 115...120(3) PA236 -- PL236 -- -- -- 110...115(1) Bulletin 700-P Operating Coil -- PA322 -- PL322 -- 115...125 -- -- -- -- 120§ PA322 -- PL322 -- 130...140 -- -- -- -- 200...208 PA249 -- -- -- 220...230 PA251 PA339 -- -- 230...240 PA254 PA342 PL254 -- 230...250 -- -- -- -- 277 PA260 -- -- -- 380 -- PA354 -- -- 415 -- PA357 -- -- 440...460 -- PA360 -- -- 460...480 PA273 -- -- -- Bulletin 700-PL Unlatch Coil and 500 -- -- -- -- Magnet Assembly 575...600 PA278 -- -- -- (1) This coil is optimized for 110...115V, 50 Hz applications and will operate satisfactorily at 120V, 60 Hz. (2) Coils for AC relays cannot be used in DC relays and vice versa. (3) This coil is optimized for 115...120V, 60 Hz applications and will operate satisfactorily at 110V, 50 Hz. -- PM735 -- -- -- -- -- PM748 -- -- -- -- -- -- -- PD735 -- -- -- -- -- PD748 -- -- -- -- -- -- PD758 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 157 Relay and Timer Specifications Contact Cartridges (Convertible from N.O. to N.C. and N.C. to N.O.) Photo Description Continuous Carrying Current [A] Arrangement Standard Contact Cartridge AC Rating NEMA A600 10 DC Rating NEMA P600 Overlap Contact Cartridges Overlapping Used in pairs. N.O. contact closes before N.C. contact opens on pickup and vice versa on drop-out. (1) AC Rating NEMA A600 10 DC Rating NEMA P150 125V DC, 138 VA 5 Make and Break Pkg. Quantity Cat. No. 1 700-CP1 2 700-CP11Z Master Contact Cartridge AC Rating Twice NEMA A600 20 DC Rating NEMA N150 P600 1 700-CPM Logic Reed Cartridge for Low Energy Circuits 150V AC 500 mA 25 VA Max. 30V DC 200 mA 6W Max. (2) Maximum 150V AC 500 mA Maximum 30V DC 200 mA 1 700-CPR (1) Not Direct Drive (2) The 700-CPR Logic Reed cartridge must be installed only in the 2nd deck (B1X - B4X, B1Y - B4Y position) or 3rd deck (C1X - C4X, C1Y - C4Y position) of the Bulletin 700 Type P relay. It is not recommended that the 700-CPR cartridge be installed in the single deck (A1X - A4X, A1Y - A4Y position) because this may lead to improper operation. 158 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Electrically Held Relays -- Typical Wiring Diagrams Relay and Timer Specifications Rockwell Automation Publication 700-TD552F-EN-P - January 2021 159 Relay and Timer Specifications Pneumatic Time-Delay Unit · Timing Range -- 0.1...60 s · 0, 2, or 4 instantaneous contacts · Two timed contacts -- both ON Delay or both OFF Delay · Convertible from ON Delay to OFF Delay and vice versa · Standard contact cartridges rated NEMA A600 (AC) and P600 (DC) · Master contact cartridges rated 2X NEMA A600 (AC) and N150 P600 (DC) Photo Operating Mode On-Delay Off-Delay No. of Timed Contacts (1) N.O. N.C. Continuous Carrying Current [A] 10 1 1 20 Arrangement Timing Range Open Type Without Enclosure(2) Cat. No. 700-PT 0.1...60 s 700-PKT (1) In addition to instantaneous cartridges on the relay (2) Mounts on 4-pole Bulletin 700-P or -PK relay or 2-pole Bulletin 700-PH relay. Mechanical Latch Units Photo Description Arrangement AC-Operated Latch Units DC-Operated Latch Units Continuous Carrying Current [A] No cartridge 10 20 No cartridge 10 20 Cat. No. 700-PLL 700-PLL11 700-PKLL11 700DC-PLL 700DC-PLL10 700DC-PKLL10 AC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PLL becomes Cat. No. 700-PLLA1. Hz 24 110 110-115 115-120 120 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600 50 B24 A1 (1) B11 (2) -- -- -- -- -- -- -- -- -- -- -- -- -- 60 A24 -- -- A1 (1) B11(2) -- -- A2 -- -- -- -- -- -- -- -- (1) Optimized for 115...120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. (2) Optimized for 110...115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz. DC Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PLL becomes Cat. No. 700DC-PLLZ24. 24 48 64 72 115-125 230-250 575-600 Z24 Z48 -- Z72 Z1 Z2 Z6 160 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Accessories Photo Relay and Timer Specifications Description Relays per Strip 4 Relay Rail Simplifies panel layout. These indexed strips are easily cut to the 8 required length and bolted, riveted, or spot-welded in place. Relays are installed adjacent to one another on the mounting strip with the 12 captive mounting screws provided. Rows of relays on Relay Rail form their own wiring trough. Can be used with the following relays: 700P, 700DC-P, 700S-P, 700N, 16 700-R, 700-RTC Pkg. Quantity 5 5 5 5 Cat. No. 700-MP4 700-MP8 700-MP12 700-MP16 DIN Rail Adapter Can be used with the following relays: Bulletin 700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC 1 700-DRA DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 Type 1 Enclosure -- Use for all Bulletin 700-P relays except 10- and 12-pole DC relays or 6-pole DC Bulletin 700-PH relays. 1 Type 4/4X Enclosure -- For 2- and 4-pole Bulletin 700-P, -N, and -R relays and 2-pole heavy duty relays. 1 Type 7 & 9 Enclosure -- For 2- and 4-pole Bulletin 700-P, -N, and -R relays and 2-pole heavy duty relays. 1 conduit hub; top and bottom. 1 199-DR1 700-N31 700-N39 700-N33 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 161 Relay and Timer Specifications Accessories Photo Description Pkg. Quantity Cat. No. Surge Suppressors (RC Circuit) -- Surge suppressors reduce the high transient voltages generated when the coil circuit is opened. These suppressors can be used with Bulletin 700-P, -PH, -PK, and -N relays, and other electromechanical devices. They contain a resistor and capacitor. Maximum ratings: 150V, AC or DC, 35 VA. Cat. No. 700-N5 requires 1 in. additional depth of enclosure. Mounting behind relay 1 Mounting on coil terminal 1 Surge Suppressor 24...48V AC/DC 1 When the circuit to a DC operating coil is opened, the inductive energy stored in the coil can generate very high transient voltages. With the addition of the appropriate surge suppressor, the stored energy is absorbed and dissipated 50...120V AC/ DC 1 limiting the voltage spikes. A surge suppressor is not required with AC 700-R or - RM relays because the AC operating coil transients are suppressed by a full wave rectifier connected to the coil. 130...250V AC/ DC 1 Diode Surge Suppressor -- for 6...300V DC voltage coils. Used on Bulletin 700-P, -PH, -PK, -N, -F, and -R relays. 1 35 A Jumper Kit CSA Approved, UL Listed This 35 A Jumper Kit can be used with any Bulletin 700-P and -PK AC or DC relay, Time-Delay relay or Latch Unit equipped with 20 A Master Cartridges. It does not require any additional panel space. Jumper Kit terminals are designed for one #8 AWG wire or two #10 AWG wires. When connecting the two 20 A Master Cartridges in parallel, it is important that they be the same configuration (Normally 1 Open or Normally Closed). Jumpers can be added to any contact cartridge location on a relay except the two center poles because of the wide spacing. An adhesive label is included with each kit listing the contact ratings. 700-N5 700-N24 199-FSMA9 199-FSMA10 199-FSMA11 199-FSMZ-1 700-CPH Cat. No. 700-N3 Jumpers (Not applicable for Bulletin 700-PH or -PK relays) For connection Jumper For between a middle pole and an outer pole on the left or right side of the relay. outer poles 50 Cat. No. 700-N4 Jumpers (Not applicable for Bulletin 700-PH or -PK relays) For connection between two middle poles. Jumper For middle poles Check Out Tool -- Mechanically maintains the Bulletin 700-P, -PH, or -PK relay in the energized position for troubleshooting purposes. 1 Adapter Plate -- Simplified relay conversion. Allows you to use the existing mounting holes when you replace a Bulletin 700-B, -BR, -BX, or -D relay with a Bulletin 700-P, -PH, or -PK relay. 700-N3 700-N4 700-N23 700-N34 162 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications IP 2X Finger-Safe Cover Accessories Photo Description Pkg. Quantity Top Covers (Covering Top Level Contact Screws) IP2X Top Cover for 700-P 1 Timer Top Cover Kit 1 Latch Top Cover Kit (for Relays with Mechanical Latch Attachment) 1 Timer Top Cover Kit, (for Master Cont. Relays with Pneumatic Timer) 1 Latch Top Cover Kit (for Master Cont. Relays with Mechanical Latch) 1 Deck Covers (Covering all terminals not on top deck, only for multi-deck relays) IP2X Deck Cover for all AC & DC Relays in the 700P Range 1 Coil Covers IP2X Coil Cover for all AC Relays in the 700P Range 1 IP2X Coil Cover for all DC Relays in the 700P Range 1 Cat. No. 700-PFSC 700-PFSTC 700-PFSLCK 700-PFSKTC 700-PFSKLCK 700-PFSDEK 700-PFSACC 700-PFSDCC Rockwell Automation Publication 700-TD552F-EN-P - January 2021 163 Relay and Timer Specifications Specifications - 700-P Relays Type Standard Cartridge Master Cartridge Heavy duty Bulletin No. 700-P 700-PMCKIT 700-PHDKIT Electrical Contact Rating Continuous 10 A @ 600V AC ; 5 A @ 600V DC 20 A @ 600V AC; 10 A @ 600V DC 35 A @ 600V AC; 20 A @ 600V DC AC Ratings Make/Break DC NEMA A600 NEMA P600 2 x NEMA A600 N150 P600 2 x NEMA A600 N150 P600 Additional Contact Ratings for AC single-phase loads 3 Hp @ 240V AC - N.O. 5 Hp @ 240V AC - N.O. 2 Hp @ 240V AC - N.O./N.C. 3 Hp @ 240V AC - N.O./N.C. -- 1 Hp @ 120V AC - N.O./N.C. 2 Hp @ 120V AC - N.O./N.C. 20 A Resistive Heating to 600V AC 35 A General Use At 0.75 PF to 600V AC 20 A Tungsten Lighting Load to 480V AC 35 A Tungsten Lighting Load to 480V AC DC Current Ratings Make/Break Cartridge Cat. No. 700-CP1 Cartridge Cat. No. 700-CPM Cartridge Cat. No. 700-CPH Volts DC DC Switching Inductive Load Contacts in Series 1 24 64 125 250 500 600 24 64 125 250 500 600 24 64 125 250 500 600 480 480 275 138 135 120 W W W WW W 5 A 2.2 A 1.1 A .55 A .24 A .2 A 10 A 5 A 2.2 A .55 A .24 A .2 A 10 A 5 A 2.2 A .55 A .24 A .2 A 2 10 A 10 A 5 A 2 A .7 A .5 A 20 A 10 A 5 A 2 A .7 A .5 A 20 A 10 A 5 A 2 A .7 A .5 A 3 -- -- 7 A 3 A 1.5 A 1.0 A -- 15 A 7 A 3 A 1.5 A 1.0 A -- 15 A 7 A 3 A 1.5 A 1.0 A 4 -- -- 10 A 5 A 2.5 A 1.5 A -- 20 A 10 A 5 A 2.5 A 1.5 A -- 20 A 10 A 5 A 2.5 A 1.5 A AC 85...110% 85...110% 85...110% Coil Voltage Range DC 80...110% 80...110% 80...110% Battery 85...115% 85...115% 85...115% Inrush Coil Consumption AC Sealed Inrush DC Sealed PLL - PKLL AC Latch Unit Inrush Sealed PLL - PKLL DC Latch Unit Unlatch Intermittent 50 Hz 132VA (2) 19.3VA (2) 15VA (2) 5.4VA (2) 12.7VA (2) 12.7VA (2) 35VA (2) 35 W (2) 60 Hz 138VA (2) 19VA (2) 15.6VA (2) 5.5VA (2) 50 Hz 132VA (2) 19.3 VA (2) 5VA (2) 5.4VA (2) 12.7VA (2) 12.7VA (2) 35VA (2) 35 W (2) 60 Hz 138VA (2) 19VA (2) 15.6VA (2) 5.5VA (2) 50 Hz 132VA (2) 19.3VA (2) 15VA (2) 5.4VA (2) 12.7VA (2) 12.7VA (2) 60 Hz 138VA (2) 19VA (2) 15.6VA (2) 5.5VA (2) -- -- Reset Time PT PKT 75 ms 75 ms -- Minimum Pulse PLLPKLL 75 ms 75 ms -- Mechanical Operating Time Pickup Dropout AC 10...20 ms / DC 30...50 ms AC 10...20 ms / DC 20...33 ms AC 10...20 ms / DC 30...50 ms AC 10...20 ms / DC 20...33 ms AC 10...20 ms / DC 30...50 ms AC 10...20 ms / DC 20...33 ms Mechanical Life 10 million operations Construction Contact Arrangement Up to 12 Poles, Convertible to N.O. or N.C. (8 N.C. Maximum) Up to 6 Poles, Convertible to N.O. or N.C. (4 N.C. Maximum) Contact Material Silver Nickel Silver Cadmium Oxide Silver Cadmium Oxide Mounting Panel, Strip Mount, or DIN Rail Horizontal Mounting Recommended Temperature Operating (1) Storage 20...+65 °C (4...+149 °F) 40...+65 °C (40...+149 °F) Environmental 20...+65 °C (4...+149 °F) 40...+65 °C (40...+149 °F) 20...+65 °C (4...+149 °F) 40...+65 °C (40...+149 °F) Wire Terminations Wire size per UL/CSA #18 AWG...(2) #12 AWG Tightening Torque 8...12 lb·in (0.9...1.4 N·m) Standards Compliance UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1 Certifications cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS (1) Temperature inside the panel. (2) Average value for all coils within range. For values on a specific coil voltage, contact your local Rockwell Automation sales office or Allen-Bradley distributor. 164 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications International Symbol for Mechanically Linked Contacts Dimensions - 700-P Relays with standard, master contact, or heavy-duty contact cartridge Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 103.43 (4-5/64) -- 171.68 (6-49/64) 1/2 2.77 (7/64) 2- and 4-pole 700-P Relay Approx Shipping Weight: AC 0.68 kg (1.5 lb), DC 1.34 kg (2.95 lb) AC 136.75 (5-25/64) 2.77 (7/64) 2- and 4-pole 700-P with Pneumatic Time Delay Attachment Approx Shipping Weight: AC 0.85 kg (1.88 lb), DC 1.5 kg (3.33 lb) 171.68 (6-49/64) 2.77 (7/64) 6- and 8-pole 700-P Relay with one -PB adder deck Approx Shipping Weight: AC 0.79 kg (1.75 lb), DC 1.45 kg (3.20 lb) AC 136.75 (5-25/64) 2.77 (7/64) 700-P Relay with Mechanical Latch Attachment Approx Shipping Weight: AC 0.97 kg (2.13 lb), DC 1.62 kg (3.58 lb) Cat. No. 700 2.77 (7/64) 700-P Relay, up to 12 poles with -PB and -PC adder decks Approx Shipping Weight: AC 1.02 kg (2.25 lb), DC 1.68 kg (3.7 lb) #8 Screws (Captive) Relay Rail for 700-P, -N, -NM, -R, -RM, -RT, -RTA Relays Secure the mounting strip with two screws at each end relay position. Use a minimum of one screw at the 3rd, 5th, 7th, etc., relay positions. Alternate between upper and lower horizontal slots. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 165 Relay and Timer Specifications 178.60 (7-1/32) Cat. No. 700-N31, Type 1 Enclosure for 700-P, -RTC Relays Approximate Shipping Weight: 1.26 kg (2.8 lb) 5.2 (13/64) 50 (1-63/64) 1000 (39-3/8) 6.2 12.5 (15/64) (1/2) 1.0 (0.04) 35.0 (1.38) 7.5 (0.3) 27.0 (1.06) Cat. No. 199-DR1 DIN Mounting Rail Series B Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes AC 170.49 (6-23/32) DC 187 (7-25/64) 700-PS Timer 700-PS Timer Mounted on a 700-P Relay Approximate Shipping Weight: AC 0.68 kg (1.5 lb) without 700-PS, DC 1.34 kg (2.9 lb) without 700-PS 3.98 (0.16) 2.25 0.5 (0.09) (.02) 0.5 (.02) DIN Rail Adapter 166 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700S-P and 700S-PK -- Heavy-Duty Safety Control Relays · Mechanically linked contacts meet IEC 947-5-1-L · 2...12 poles all mechanically linked · Red cover for easy identification of safety circuits · Tamper resistant cover helps prevent changes which could jeopardize safety · IEC mechanically linked contacts symbol displayed on front · Visual indication of contact state · Ideal for use in safety circuits 700S-P (10 A) Safety Control Relays -- AC and DC Coil Voltages Contacts AC Coils 24V DC Coils Open Type Panel Mount Relay Rail Mount Open Type Panel Mount Relay Rail Mount Open Type DIN Rail Mount N.O. N.C. Cat. No. 3 1 700S-P310 2 2 700S-P220 7 1 700S-P710 6 2 700S-P620 5 3 700S-P530 4 4 700S-P440 3 5 700S-P350 10 2 700S-P1020 Cat. No. 700S-DCP310Z24 700S-DCP220Z24 700S-DCP710Z24 700S-DCP620Z24 700S-DCP530Z24 700S-DCP440Z24 700S-DCP350Z24 700S-DCP1020Z24 Cat. No. 700S-DCP310DZ24 700S-DCP220DZ24 700S-DCP710DZ24 700S-DCP620DZ24 700S-DCP530DZ24 700S-DCP440DZ24 700S-DCP350DZ24 700S-DCP1020DZ24 AC Coil Voltage Code(1) The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: Cat. No. 700S-P310 becomes Cat. No. 700S-P310A1 for a 120V AC coil. [V] 24 60 Hz A24 115-120 A1 230-240 A2 460-480 A4 IEC 947-5-1 Annex L has 2 requirements for a relay to meet for mechanically linked contacts: 1.) If a N.O. contact welds, all the N.C. contacts will remain open and meet a 2500V impulse test. 2.) If a N.C. contact welds, all the N.O. contacts will remain open and meet a 2500V impulse test. 700S-P and 700S-DCP relays meet these requirements including the 2500V impulse test. The relays shown on this page are shipped from the factory with the 700-CPS safety cartridge installed and cannot be converted to N.O. or N.C. in the Field. (1) For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 167 Relay and Timer Specifications 700S-PK (20 A) Safety Control Relays Contacts N.O. N.C. 7 1 6 2 5 3 4 4 3 5 10 2 3 1 7 1 6 2 5 3 4 4 3 5 10 2 3 1 Coil Voltage 110V AC 110V AC 110V AC 110V AC 110V AC 110V AC 110V AC 24V DC 24V DC 24V DC 24V DC 24V DC 24V DC 24V DC Cat. No. 700S-PK710A1 700S-PK620A1 700S-PK530A1 700S-PK440A1 700S-PK350A1 700S-PK1020A1 700S-PK310A1 700S-DCPK710Z24 700S-DCPK620Z24 700S-DCPK530Z24 700S-DCPK440Z24 700S-DCPK350Z24 700S-DCPK1020Z24 700S-DCPK310Z24 168 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700S-P Relays Type 700S-P Electrical Contact Rating Continuous 10 A @ 600V AC 5 A @ 600V DC AC Ratings Make/ Break DC NEMA A600 NEMA P600 Minimum Contact Switching Ratings 10V, 50 mA Contacts in Series 24V Volts DC 64V 125V 250V 500V DC 1 Switching Inductive Load 2 5 A 2.2 A 1.1 A 0.55 A 0.24 A 10 A 10 A 5 A 2 A 0.7 A 3 -- -- 7 A 3 A 1.5 A 4 -- -- 10 A 5 A 2.5 A Contact Electrical Life-- Resistive Loads 1.5 million operations at 10A break at 120V AC 14 million operations at 1A break at 120V AC 6 million operations at 1A break at 24V DC AC Coil Voltage Range (1) DC 85...110% 80...110% Battery Charging 85...115% Coil Consumption 50 Hz 60 Hz Inrush AC Sealed 132 VA 19.3 VA 138 VA 19 VA Inrush DC Sealed 12.7 W 12.7 W Mechanical Mechanically Linked Contacts All contacts are mechanically linked per IEC 947- 5-1 annex L for 2 to 12 poles Operating Time Pickup Dropout AC 10...20 ms DC 30...50 ms AC 10...20 ms DC 20...33 ms Mechanical Life 10 million operations Construction Contact Arrangement 2...12 Poles, Double Break Contacts N.O. or N.C. (8 N.C. Maximum) Contact Material/Design Silver Nickel/Bifurcated Mounting Panel mount or mount on 700-MP Relay or DIN Rail Horizontal Mounting Recommended Environmental Operating Temperature (2) -20...+65 °C (-4...+149 °F) Storage Temperature -40...+65 °C (-40...+149 °F) Wire Terminations Wire size per UL/CSA #18 AWG...(2) #12 AWG Tightening Torque 8...12 lb·in (0.9...1.4 N·m) Standards Compliance UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1 Certifications cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS (1) Coil voltage required for proper operation (percent of rated coil voltage). (2) Temperature inside the panel. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 600V 0.2 A 0.5 A 1.0 A 1.5 A 169 Relay and Timer Specifications Specifications - 700S-PK Relays Type 700S-PK Electrical Contact Rating Continuous 20 A @ 600V AC 10 A @ 600V DC AC Ratings Make/ Break DC NEMA A600 NEMA P600 Additional Contact Ratings for AC Single-Phase Loss 3 Hp @ 240V AC - N.O. 2 Hp @ 240V AC - N.O./N.C. 1 HP @ 120V AC - N.O./N.C. 20 A resistive heating to 600V AC 20 A Tungsten lighting load to 480V AC DC Current Ratings Make/Break Cartridge Cat. No. 700-CMS Contacts in Series Volts DC 24V 64V 125V 250V 500V 600V DC 1 Switching 2 10 A 5 A 2.2 A 0.55 A 0.24 A 0.2 A 20 A 10 A 5 A 2 A 0.7 A 0.5 A 3 -- 15 A 7 A 3 A 1.5 A 1.0 A 4 -- 20 A 10 A 5 A 2.5 A 1.5 A AC Coil Voltage Range (1) DC 85...110% 80...110% Battery Charging 85...115% Coil Consumption 50 Hz 60 Hz Inrush AC Sealed 132 VA 19.3 VA 138 VA 19 VA Inrush DC Sealed 12.7 W 12.7 W Mechanical Mechanically Linked Contacts All contacts are mechanically linked per IEC 947-5-1 annex L for 2 to 12 poles Operating Time Pickup Dropout AC 10...20 ms, DC 30...50 ms AC 10...20 ms, DC 20...33 ms Construction Contact Arrangement Contact Material/Design Mechanical (Mechanically-Linked Contacts) 2...12 Poles, Double Break Contacts N.O. or N.C. (8 N.C. Maximum) Silver Cadmium Oxide All contacts, are mechanically linked per IEC 947-5-1 Annex L for 2 to 12 poles Mounting Panel mount or strip mount recommended Environmental Operating Temperature (2) Storage Temperature -20...+65 °C (-4...+149 °F) -40...+65 °C (-40...+149 °F) Wire Terminations Wire size per UL/CSA Tightening Torque Standards Compliance UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1 #18 AWG...(2) #12 AWG 8...12 lb·in (0.9...1.4 N·m) Certifications cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS (1) Coil voltage required for proper operation (percent of rated coil voltage). (2) Temperature inside the panel. 170 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700S-P Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 103.43 (4-5/64) AC 136.75 (5-25/64) 1/2 2.77 (7/64) 2- and 4-pole 700S-P Relay Approximate Shipping Weight: AC 0.68 kg (1.5 lb), DC 1.34 kg (2.95 lb) 170.10 (6-45/64) 2.77 (7/64) 6- and 8-pole 700S-P Relay Approximate Shipping Weight: AC 0.79 kg (1.75 lb), DC 1.45 kg (3.20 lb) Cat. No. 700 2.77 (7/64) 10- and 12-pole 700S-P (Captive) Approximate Shipping Weight: AC 1.02 kg (2.25 lb), DC 1.68 kg (3.7 lb) 5.2 (13/64) 50 (1-63/64) 6.2 12.5 (15/64) (1/2) 1000 (39-3/8) DIN Rail 1.0 (0.04) 35.0 (1.38) 7.5 (0.3) 27.0 (1.06) Relay Rail #8 Screws (Captive) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 171 Relay and Timer Specifications 700-N Industrial Relays · Contact cartridges convertible from N.O. to N.C. and vice versa · NEMA A300 AC · 24...250V AC coils · Pneumatic timing unit · Solid-state timing unit · Overlap contacts · Logic reed contacts · 4-...8-pole AC-Operated Relays Photo Contacts N.O. N.C. Contact Arrangement 4 -- Open Type Cat. No. 700-N400 Type NM Relay 2 Poles§ 2 -- 700-NM200 AC Coil Voltage Code The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-N200 becomes Cat. No. 700-N200A24 for 24V 60 Hz. For other coil voltages, contact your local Rockwell Automation sales office or Allen-Bradley distributor. [V] 50 Hz 60 Hz 24 -- A24 110 A1 -- 120 -- A1 208 -- A20 220 A2 -- 240 -- A2 IMPORTANT · NORMALLY CLOSED CONTACTS: Listed relays are supplied with all contacts normally open. These contacts can be readily converted to normally closed in the field. · OVERLAP CONTACTS: Overlap contacts (normally open contact closes before the normally closed contact opens) can be supplied. See for information on kits for field installation of overlap contact cartridges. · Location of contacts in 2-pole relays · Permanent Magnet Latch AC Relay. Minimum Operating Time - Type NM - For reliable operation, power to the latch circuit must be maintained for a minimum time of 75 milliseconds and power to the unlatch circuit must be maintained for minimum time of 50 milliseconds. 172 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Operating Coils Photo Coil Voltage 24 110 120 208 220 240 700-NT Pneumatic Timing Unit Photo Description Timing Unit Only (for 700-N, 2...4-pole) Relay and Timer Specifications 700-N Relay · 2-...8-Pole 60 Hz 84AB27 84AB01 84AB86 84AB113 84AB06 84AB83 50 Hz 84AB28 84AB86 -- -- 84AB83 -- Timed Contacts Contact Arrangement Open Type N.O. N.C. ON-Delay mode is 1 1 standard. Timer is easily converted to OFF-Delay mode. Cat. No. 700-NT Rockwell Automation Publication 700-TD552F-EN-P - January 2021 173 Relay and Timer Specifications Specifications - 700-N Relays Attribute Electrical Ratings Rated Thermal Current Ith Rated Insulation Voltage Contact Rating Coil Voltage Range AC DC Coil Consumption AC Mechanical Inrush Sealed Max. Operating Time Timing Range Repeat Accuracy Reset Time Timing Mode Pickup Drop Out Construction Contact Arrangement Contact Material Mounting Environmental Ambient Temperature (Outside Enclosure) Operating Storage Operating Temperature Rise (Inside Enclosure) Wire Terminations Wire size per UL/CSA Tightening Torque Standards Compliance Certifications Bul. 700-N Bul. 700-NT 10 A 300V 10 A @ 300V AC, NEMA A300 85...110% -- 80...110% -- 50 Hz 60 Hz -- 120 VA 133 VA -- 24 VA 20 VA -- AC 14 ms 13 ms -- -- -- -- -- -- -- 0.2...60 s ±15% of setting 75 ms On-Delay -- convertible to OFF Delay, up to 2 poles convertible to N.O. or N.C. Up to 8 Poles, Convertible to N.O. or N.C. Silver Panel or strip mount Horizontal mounting recommended -- Silver On relay only 20...+40 °C (4...+104 °F) 40...+60 °C (40...+140 °F) +25 °C Max -- #18 AWG...(2) #12 AWG 8...12 lb·in. (0.9...1.4 N·m) UL 508, CSA C22.2, No. 14 cULus Listed (File No. E14840, Guide NKCR/NKCR7) 174 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700-N Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Type of Relay 700 N 700 N with Pneumatic 700 Timer N with Solid-State 700 Timer No. of Poles Drawing Number Open Type Without Enclosure A B C Wide High Deep Approx Type 1 . Ship. General Purpose Enclosure Wt. kg D (lbs.) A B C D Wide High Deep Approx . Ship. Wt. kg E (lbs.) 2...4 1 57.15 (2-1/4) 88.90 (3-1/2) 82.55 (3-1/4) 79.38 (3-1/8) 0.68 (1-1/2) 107.95 (4-1/4) 185.74 (7-5/ 16) 103.19 (4-1/ 16) 146.05 (5-3/4) 85.73 (3-3/8) 1.59 (3-1/2) 6...8 2 57.15 (2-1/4) 88.90 (3-1/2) 106.36 (4-3/ 16) 79.38 (3-1/8) 0.79 (1-3/4) 112.71 (4-7/ 16) 228.60 (9) 120.65 (4-3/4) 206.38 (8-1/8) 92.08 (3-5/8) 2.27 (5) 2...4 3 57.15 (2-1/4) 88.90 (3-1/2) 138.11 (5-7/ 16) 79.38 (3-1/8) 0.91 (2) -- -- -- -- -- -- 2...4 3 57.15 (2-1/4) 88.90 (3-1/2) 160.34 (6-5/ 16) 79.38 (3-1/8) 1.02 (2-1/4) -- -- -- -- -- -- C A C A C A DB DB DB Drawing Number 1 178.60 (7-1/32) Drawing Number 2 Cat. No. 700 Drawing Number 3 5.2 (13/64) 50 (1-63/64) 1000 (39-3/8) 6.2 (15/64) 12.5 (1/2) #8 Screws (Captive) 1.0 (0.04) 35.0 (1.38) 7.5 (0.3) 27.0 (1.06) 3.98 (0.16) 2.25 0.5 (0.09) (.02) 0.5 (.02) DIN Rail Adapter Rockwell Automation Publication 700-TD552F-EN-P - January 2021 175 Relay and Timer Specifications 700-R Sealed Switch Relays · Sealed contacts · Extremely long mechanical and electrical life · Hazardous locations Class 1, Div 2 Groups A, B, C, D · Harsh environments · Suitable for applications with shock and vibration · High reliability circuit integrity Electrically Held No. of Contacts Contact Arrangement Poles and Markings N.O. N.C. 0 0 0 Relay without Contact 2 0 2 1 1 0 2 4 0 3 1 4 2 2 1 3 0 4 6 0 5 1 4 2 6 3 3 2 4 1 5 0 6 8 0 7 1 6 2 5 3 8 4 4 3 5 2 6 1 7 0 8 Arrangement displays all N.O. contacts. Location of contacts in 6-pole relays. Polarity must be observed for DC voltage (700 DC) relays. Location of contacts in 2-pole relays. AC-Operated Relay Only Open Type Cat. No. 700-R000 700-R200 700-R110 700-R020 700-R400 700-R310 700-R220 700-R130 700-R040 700-R600 700-R510 700-R420 700-R330 700-R240 700-R150 700-R060 700-R800 700-R710 700-R620 700-R530 700-R440 700-R350 700-R260 700-R170 700-R080 DC-Operated Relay Only Open Type Cat. No. 700DC-R000 700DC-R200 700DC-R110 700DC-R020 700DC-R400 700DC-R310 700DC-R220 700DC-R130 700DC-R040 700DC-R600 700DC-R510 700DC-R420 700DC-R330 700DC-R240 700DC-R150 700DC-R060 700DC-R800 700DC-R710 700DC-R620 700DC-R530 700DC-R440 700DC-R350 700DC-R260 700DC-R170 700DC-R080 Coil Voltage Code The Cat. No. as listed is incomplete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 700-R000 becomes Cat. No. 700-R000A24. Type of Relay AC DC [V] 25, 50, 60 Hz -- Coil Volts 24 48 110 115-125 120 220 230-250 240 -- -- A1 -- -- A2 -- -- A24 -- -- -- A1 -- -- A2 Z24 Z48 -- Z1 -- -- Z2 -- 176 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Accessories - 700-R Relays Photo Relay and Timer Specifications Description Relay Rail Simplifies panel layout. These indexed strips are easily cut to the required length and bolted, riveted, or spot-welded in place. Relays are installed adjacent to one another on the mounting strip with the captive mounting screws provided. Rows of relays on Relay Rail form their own wiring trough. Can be used with the following relays: 700P, 700DC-P, 700S-P, 700N, 700-R, 700-RTC 4 Relays per Strip 8 Relays per Strip 12 Relays per Strip 16 Relays per Strip DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m Pkg. Qty. Cat. No. 5 700-MP4 5 700-MP8 5 700-MP12 5 700-MP16 10 199-DR1 DIN Rail Adapter Can be used with the following relays: 700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC 1 700-DRA Front Deck A front deck can be attached to 700 2-, 3-, or 4pole AC and DC Type R relays. Front Deck with one N.O. Contact Cartridge (700-R Relay) 1 Front Deck with one N.C. Contact Cartridge (700-R Relay) 1 Front Deck with one N.O. Contact Cartridge (700-RM Relay) 1 Front Deck with one N.C. Contact Cartridge (700-RM Relay) 1 Contact Cartridges N.O. Contact Cartridge - Green These cartridges are used to increase the number (700-R Relay) 1 of poles of a relay. A dummy cartridge is also available to fill empty space not occupied by a contact cartridge. N.C. Contact Cartridge - Yellow (700-R Relay) 1 700-RA10 700-RA01 700-RB10 700-RB01 700-CR5 700-CR6 Cat. No. 700-CR5 Cat. No. 700-CR6 Cat. No. 700-CR9 "DUMMY"Cartridge - Black (700-R Relay) 1 Surge Suppressor 12V DC (700-R Relay) 1 When the circuit to a DC operating coil is opened, 24V DC (700-R Relay) 1 the inductive energy stored in the coil can generate very high transient voltages. With the 48V DC (700-R Relay) 1 addition of the appropriate surge suppressor, the stored energy is absorbed and dissipated 115...125V DC (700-R Relay) 1 limiting the voltage spikes. A surge suppressor is not required with AC 700-R relays because the AC operating coil transients are suppressed by a full 230...250V DC (700-R Relay) 1 wave rectifier connected to the coil. 700-CR9 199-FSMA9 199-FSMA10 199-FSMA11 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 177 Relay and Timer Specifications Specifications - 700-R Application Data Because of the inherent characteristics of this device, the normally open contacts may close before the normally closed contacts open on energization and the normally closed contacts may close before the normally open contacts open on de-energization. Ratings NEMA Rating Designation Voltage AC Voltage Make 120V 30 B300 Up to 300V AC 240V 15 480V 3.75 C600 Above 300V AC 600V 3.0 Maximum Allowable Off-State Leakage Current Break 3 1.5 0.375 0.30 Continuous NEMA Rating Carrying Designation Current [A] DC Voltage Volts DC Make/Break Continuous Carrying Current [A] 5 46...300 138 VA 5 NEMA P300 2.5 5...46 3 A 5 24V DC 24V AC 120V AC Relay Data Voltage Maximum Off-State Leakage Current [mA] Type R 23 23 5 Type Contact Arrangement Contact Material Coil Voltage Range Coil Power Sealed Voltage Range: 15... +10% Inrush Pickup Time Dropout Time Operating Temperature Mounting Haz. Loc. Ratings Standards Compliance Certifications 700-R Up to 8 poles, available in any combination of N.O. or N.C. contacts W (tungsten in a controlled gas atmosphere) 24...250V AC 24...250V DC 5.5 VA, 50/60 Hz 5.5 W DC 5.5 VA, 50/60 Hz 5.5 W DC 30 ms 30 ms 40...+60 °C (40...+140 °F) Panel mount Class I, Division 2, Groups A, B, C, and D ISA 12.12, CSA C22.2, No. 213, EN/IEC 60947-1, -5-1 cULus Listed (File No. E10314, Guide NOIV/NOIV7), CE Marked 178 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-R Operating Coils Coil Volts 24 48 110 115...125 120 208 220 240 230...250 60 Hz 77AB27 77AB134 77AB86 -- 77AB86 -- 77AB83 77AB83 -- 700-R 2-...8-Pole AC 50 Hz 77AB27 77AB134 77AB86 -- 77AB86 -- 77AB83 77AB83 -- 700-R 2-...8-Pole DC 77D152 77D166 -- 77D155 -- -- -- -- 77D156 Dimensions - 700-R Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Type of Relay R 700 and 700DC No. of Poles 2...4 5...8 Drawing Number 1 2 700-R Relays Open Type Without Enclosures A B C D Wide High Deep 55.56 (2-3/ 16) 88.90 (3-1/2) 92.25 (3-3/8) 79.38 (3-1/8) 55.56 (2-3/ 16) 88.90 (3-1/2) 111.13 (4-3/8) 79.38 (3-1/8) Approx . Ship Wt. [kg (lb)] 0.91 (2) 1.02 (2-1/4) A Wide 104.78 (4-1/8) 112.71 (4-7/ 16) Type 1 General Purpose Enclosure B C D High Deep 185.74 (7-5/ 16) 103.19 (4-1/ 16) 146.05 (5-3/4) 228.60 120.65 206.38 (9) (4-3/4) (8-1/8) Approx . Ship E Wt. [kg (lb)] 85.73 1.81 (3-3/8) (4) 92.08 2.49 (3-5/8) (5) C A C A B D B D 700-R400... A C D B E Type 1 Enclosure 700-R800... 3.98 (0.16) 2.25 0.5 (0.09) (.02) 0.5 (.02) DIN Rail Adapter Rockwell Automation Publication 700-TD552F-EN-P - January 2021 179 Relay and Timer Specifications Cat. No. 700 #8 Screws (Captive) Relay Rail Secure the mounting strip with 2 screws at each end relay position. Use a minimum of one screw at the 3rd, 5th, 7th, etc., relay positions. Alternate between upper and lower horizontal slots. 5.2 (13/64) 50 (1-63/64) 6.2 12.5 (15/64) (1/2) 1.0 (0.04) 35.0 (1.38) 27.0 (1.06) 1000 7.5 (39-3/8) (0.3) Cat. No. 199-DR1 DIN Mounting Rail Series B 180 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-RTC -- Solid-State Timing Relay · Timing functions · 8 ON-delay · 8 OFF-delay · Timing ranges · Seconds: 0.05...2, 0.2...8, 0.4...30, 2...120 · Minutes: 0.015...1, 0.06...4, 0.25...16 and 1...64 · AC, 50/60 Hz or DC · 600V AC maximum · 300V DC maximum · Relays with fixed time delay · Sealed contacts · Harsh environments · Hazardous locations Class I, Div. 2, Groups A, B, C and D 700-RTC Relay with Adjustable Time Delay Relays with Provision for Instantaneous Contacts Relays listed below have slots for two timed contacts and two instantaneous contacts. Unused slots are equipped with removable dummy cartridges. Number of Contact Cartridges Instantaneous Total N.O. N.C. 0 0 0 1 0 0 0 0 0 0 1 0 0 1 2 0 0 1 0 0 1 0 0 1 0 2 0 0 1 1 1 1 0 3 2 0 0 2 0 1 1 1 1 0 0 2 0 1 Timed N.O. N.C. 0 0 1 0 0 1 2 0 1 0 1 0 1 1 0 1 0 1 0 2 2 0 1 0 2 0 1 0 1 1 0 1 1 0 1 1 0 1 0 2 0 1 0 2 Open Type Without Enclosure Cat. No. 700-RTC00000 700-RTC00100 700-RTC00010 700-RTC00200 700-RTC10100 700-RTC01100 700-RTC00110 700-RTC10010 700-RTC01010 700-RTC00020 700-RTC10200 700-RTC20100 700-RTC01200 700-RTC11100 700-RTC10110 700-RTC20010 700-RTC02100 700-RTC01110 700-RTC11010 700-RTC10020 700-RTC02010 700-RTC01020 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 181 Relay and Timer Specifications Number of Contact Cartridges Instantaneous Total N.O. N.C. 2 0 1 1 2 0 0 2 4 1 1 2 0 1 1 0 2 0 2 Coil Voltage Code Timed N.O. N.C. 2 0 2 0 1 1 2 0 1 1 0 2 0 2 1 1 0 2 Open Type Without Enclosure Cat. No. 700-RTC20200 700-RTC11200 700-RTC20110 700-RTC02200 700-RTC11110 700-RTC20020 700-RTC11020 700-RTC02110 700-RTC02020 The Cat. No. as listed is not complete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 700-RTC00100 becomes Cat. No. 700-RTC00100U24. For other voltages consult your local Rockwell Automation sales office or Allen-Bradley distributor. [V] 50/60 Hz 24V DC, 24V AC U24 120V DC, 110/120V AC U1 700-RTC Relays with Fixed Time Delay-- Relays with Provision for Instantaneous Contacts Relays listed below have slots for two timed and two instantaneous contacts. Unused slots are equipped with removable dummy cartridges. Number of Contact Cartridges Timed Total N.O. N.C. 0 0 0 1 1 0 0 1 2 0 1 0 1 0 2 1 1 0 1 0 1 0 2 2 0 1 0 2 0 1 0 1 1 3 0 1 1 0 1 1 0 1 0 2 0 1 0 2 Instantaneous N.O. N.C. 0 0 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 2 0 0 1 1 1 1 0 2 0 0 2 0 1 1 1 1 0 0 2 0 1 Open Type Without Enclosure Cat. No. 700-RTC00#0 700-RTC10#0 700-RTC20#0 700-RTC40#0 700-RTC11#0 700-RTC12#0 700-RTC30#0 700-RTC21#0 700-RTC22#0 700-RTC50#0 700-RTC41#0 700-RTC14#0 700-RTC42#0 700-RTC13#0 700-RTC31#0 700-RTC24#0 700-RTC15#0 700-RTC32#0 700-RTC23#0 700-RTC51#0 700-RTC25#0 700-RTC52#0 182 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Number of Contact Cartridges Timed Total N.O. N.C. 2 0 2 0 1 1 2 0 4 1 1 0 2 1 1 0 2 0 2 # Operating Mode Instantaneous N.O. N.C. 2 0 1 1 2 0 0 2 1 1 2 0 0 2 1 1 0 2 Open Type Without Enclosure Cat. No. 700-RTC44#0 700-RTC43#0 700-RTC34#0 700-RTC45#0 700-RTC33#0 700-RTC54#0 700-RTC35#0 700-RTC53#0 700-RTC55#0 Replace the # in the cat. no. with the appropriate letter and numbers to indicate the operating mode and the fixed time delay value. Refer to operating mode table below. Digit Operating Mode S On-Delay s Z Off-Delay s Y On-Delay Min. I Off-Delay Min. Fixed Time Delay Seconds Two digits indicating the fixed time delay in seconds. Three digits indicating the fixed time delay (first digit indicates seconds, next two digits indicate 1/100 seconds). Minutes Two digits indicating the fixed time delay in minutes. Three digits indicating the fixed time delay (first digit indicates minutes, next two digits indicate 1/100 minutes). EXAMPLE Cat. No. 700-RTC00Y200U1 is for a relay without contact cartridges."Y20"indicates an On-Delay timer with a 20 minute fixed time delay. This is a"standard relay."Order the contact cartridges separately. Cat. No. 700-RTC42S020U1 is for a relay with 2 N.O. cartridges in the timed position and 1 N.C. cartridge in the instantaneous position. "S02" indicates an On-Delay timer with a 2 second fixed time delay. Coil Voltage Code The cat. no. as listed is not complete. To complete the cat. no., add a coil code selected from the table below. [V] 50/60 Hz 24V DC, 24V AC U24 120V DC, 110/120V AC U1 Accessories - 700-RTC Relays Photo Cat. No. 700-CRT5 Cat. No. 700-CRT6 Cat. No. 700-CR9 Description Cartridge Type Color N.O. Grey Contact Cartridges These cartridges are used to add contacts to timing relays having unused slots. The N.O., N.C., and Dummy cartridges are interchangeable and can be used in timed or N.C. instantaneous contact slots. Dummy cartridges should be placed in unused cartridge slots to guard against entrance of foreign material. Orange Dummy Cartridge Black Cat. No. 700-CRT5 700-CRT6 700-CR9 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 183 Relay and Timer Specifications Photo Description Cartridge Type Color Cat. No. Type 1 Enclosure -- Use for all 700-P relays except 10- and 12-pole DC relays or 6-pole DC 700-PH relays. 700-N31 Relay Rail Simplifies panel layout. These indexed strips are easily cut to the required length and bolted, riveted, or spot-welded in place. Relays are installed adjacent to one another on the mounting strip with the captive mounting screws provided. Rows of relays on Relay Rail form their own wiring trough. Can be used with the following relays: 700P, 700DC-P, 700S-P, 700N, 700-R, 700-RTC Relays per Strip 4 8 12 16 Pkg. Quantity 700-MP4 5 5 700-MP8 5 700-MP12 5 700-MP16 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 DIN Rail Adapter Can be used with the following relays: 700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC 1 700-DRA Specifications - 700-RTC Relays Voltage and Power Requirements AC Voltage +10% 15% 50/60 Hz 24V AC 110/120V AC Total Power Required 8 VA 9 VA Initiate Terminal Power 4 VA 4 VA Maximum Allowable Leakage Current 10 mA 2.4 mA Coil Code U24 U1 DC Voltage +10% 20% 24V DC 120V DC Total Power Required 10 W 11 W Initiate Terminal Power 5 W 5 W Maximum Allowable Leakage Current 10 mA 2.4 mA Coil Code U24 U1 Type Contact Rating Contact Arrangement Contact Material Operating Mode 700-RTC NEMA B600 600V AC, 5 A NEMA P300 300V DC, 5 A 1...4 poles. Max. of 2 timed and 2 instantaneous. Available in any combination of N.O. and N.C. contacts W (tungsten in a controlled gas atmosphere) Convertible to ON-Delay or OFF-Delay 184 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Type 700-RTC Timing Range 0.015...64 minutes; 0.05...120 seconds Reset Time 25 ms Repeat Accuracy ±1% (or ±50 ms) at constant voltage and temperature Mounting Panel or strip mount Surge Suppression Not required. Timers have internal suppression Haz. Loc. Ratings Class I, Division 2, Groups A, B, C, and D Maximum Allowable Leakage Current Ambient Temperature (1) 24V AC/DC 110/120V AC, 120V DC 10 mA 2.4 mA Operating: 20...+60 °C (4...+140 °F) Storage: 20...+60 °C (4...+140 °F) Standards Compliance ISA 12.12, CSA C22.2, No. 213 Certifications cULus Listed (File No. E10314, Guide NOIV/NOIV7) (1) Continuous duty units placed close to each other (3 in a row) have a temperature range of 20...+45 °C (4...+113 °F) or should have air circulated around the units. Approximate space of 3/4 in (mm) on all sides is needed. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 185 Relay and Timer Specifications Typical Wiring Diagram - 700-RTC Relays External L1 Initiating Contact (N.O. or N.C.) Timed Contacts Any Combination of N.O. and N.C. L2 P TIMED INST Instantaneous Contacts Any Combination of N.O. and N.C. L1 + L2 Dimensions - 700-RTC Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 5.2 (2-13/64) Dia. Mounting Holes Approximate Shipping Weight 0.92 kg (2.1 lb.) NEMA Type 1 Enclosure for RTC Relays Approximate Shipping Weight 1.26 kg (2.8 lb.) 186 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 IEC Control Relays Product Overview Relay and Timer Specifications Bulletin No. 700-CF and 700S-CF Type Control Relay Features · Mechanically linked contacts · Timer and latch operations · Switch up to 690V AC and DC · 700S-CF for safety circuits Contact Form 4...12 poles, double break Contact Type Cross stamp or bifurcated Contact Material Silver, gold Electrical Max. Current AC Resistive 20 A (relay) 10 A (adder deck) Min. load 17V, 10 mA (Silver) 5V, 3 mA (Gold) Coil Voltage 12...600V AC 9...250V DC Coil Voltage Pickup 85...110% AC coils, 80...110% DC coils Dielectric Withstand 2.5 kV Electric Service Life (cycles) 1.2 million at 10 A Certifications CE, cULus, CCC Sockets DIN Rail or panel mount Page 188 700-EF and 700S-EF Control Relay · Mechanically linked contacts · Timer and latch operations · Switch up to 690V AC and DC · 700S-EF for safety circuits 4...8 poles -- Silver 16 A (relay) 16 A (adder deck) 12V, 3 mA (Silver) 24...500V AC 12...500V DC 85...110% AC coils, 80...110% DC coils 2.5 kV 1.2 million at 6 A CE, cULus, CCC DIN Rail or panel mount 188 700-K Miniature Control Relay · Smallest size · Long life · Low power consumption · Switch up to 690V AC and DC 4...8 Poles Double Break Bifurcated Silver 10 A 15V, 2 mA (700-K) 12...600V AC 9...250V DC 85...110% AC Coils, 80...110% DC Coils 2640V 800K at 10 A 120V AC CE, cULus, CCC DIN Rail or panel mount 225 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 187 Relay and Timer Specifications 700-CF Control Relay · IEC industrial relays · Mechanically linked contact performance per IEC 60947-5-1 · Gold plated, bifurcated version for low level switching applications · Master control relay version rated 15 A (AC-15) · Solid-state and pneumatic timing modules · 4-...10 Poles 4-Pole AC Coil Voltage (Ratings for 700-CF Only) AC-12 AC-15 Ith [A] Ie [A] Connection Diagrams 40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V Contacts Standard Contacts(1) Gold Plated Bifurcated Contacts(2) Master Contacts(2) N.O. N.C. Cat. No. Cat. No. Cat. No. 2 2 700-CF220 700-CFB220 700-CFM220 20 20 10 10 10 6 2.5 1 1 3 1 700-CF310 700-CFB310 700-CFM310 4 0 700-CF400 700-CFB400 700-CFM400 0 4 700-CF040 700-CFB040 -- (1) For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D. (2) All Cat. Nos. are factory-stocked. ACoil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CF220 becomes Cat. No. 700-CF220D for 120V, 60 Hz. [V] 12 24 32 36 42 48 100 100... 110 110 120 127 200 200... 220 208 208... 240 220... 230 230 230... 240 240 50 Hz R K V W X Y KP -- D P S KG L ---- F -- VA T 60 Hz Q J -- V -- X -- KP -- D -- -- KG H L -- ---- A 50/60 Hz -- KJ -- -- -- KY KP -- KD -- -- KG KL -- -- KL KF -- KA [V] 277 347 380 380... 400 50 Hz -- -- -- N 60 Hz T I E -- 50/60 Hz -- -- -- -- 400 400... 415 -- G -- -- KN -- 440 480 500 550 600 B -- M C -- N B -- -- C KB -- -- -- -- 188 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 4-Pole DC Coil Voltage (Ratings for 700-CF Only) AC-12 AC-15 Ith[A] Ie [A] Connection Diagrams 40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V Contacts Standard Contacts(1) Gold Plated Bifurcated Contacts(2) Master Contacts(2) N.O. N.C. Cat. No. 2 2 700-CF220 Cat. No. Cat. No. 700-CFB220 700-CFM220 20 20 10 10 10 6 2.5 1 1 3 1 700-CF310 700-CFB310 700-CFM310 4 0 700-CF400 700-CFB400 700-CFM400 (1) For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D. (2) All Cat. Nos. are factory-stocked. DC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. example: Cat. No. 700-CF220 becomes Cat. No. 700-CF220EJ for 24V DC, electronic with diode. [V] 9 12 24 36 48 48... 72 60 64 72 80 110 110... 125 115 125 220 220... 250 230 250 Electronic with diode -- EQ EJ EW -- EY -- -- -- -- -- ED -- -- -- EA -- -- Electronic with diode/ Quick -- -- QJ Pick-up ------------------ -- -- -- -- -- -- Rockwell Automation Publication 700-TD552F-EN-P - January 2021 189 Relay and Timer Specifications 6- and 8-pole Relays Control Relays with Overlapping Side-Mounted Contacts AC-12 Ith [A] AC-15 Ie [A] Left Relay Contacts Right Aux. Arrangement Aux. Overlapping SideMounted Contacts Cat. No. 40 60 24/ 120 240 400 500 600 690 °C °C 48V V V V V V V N.O. N.C. N.O. N.C. Main Relay 20 20 10 10 10 6 2.5 1 1 4 0 1 1 700-CFZ1510 3 1 1 1 700-CFZ1420 2 2 1 1 700-CFZ1330 Side Contacts 10 10 6 6 5 3 1.6 1 1 4 0 2 2 700-CFZ2620 3 1 2 2 700-CFZ2530 2 2 2 2 700-CFZ2440 190 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Control Relays with Standard Side-mounted Contacts AC-12 AC-15 Ith [A] Ie [A] Left Aux. 40 60 24/ °C °C 48V 120V 240V 400V 500V 600V 690V Relay Arrangement Standard Right Aux. Contacts SideMounted Contacts Cat. No. (1) N.O. N.C. N.O. N.C. 4 0 1 1 700CFZ0510 Main Relay 20 20 10 10 10 6 2.5 1 1 3 1 1 1 700CFZ0420 2 2 1 1 700CFZ0330 4 0 2 2 700CFZ0620 Side Contacts 10 10 6 6 5 3 1.6 1 1 3 1 2 2 700CFZ0530 2 2 2 2 700CFZ0440 (1) All Cat. Nos. are factory stocked. AC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CFZ051 becomes Cat. No. 700-CFZ0510F. [V] 12 24 32 36 42 48 100 100... 110 110 120 127 200 200... 220 208 208... 240 220... 230 230 230... 240 240 50 Hz R K V W X Y KP -- D P S KG L ---- F -- VA T 60 Hz Q J -- V -- X -- KP -- D -- -- KG H L -- ---- A 50/60 Hz -- KJ -- -- -- KY KP -- KD -- -- KG KL -- -- KL KF -- KA [V] 277 347 380 380... 400 50 Hz -- -- -- N 60 Hz T I E -- 50/60 Hz -- -- -- -- 400 400... 415 -- G -- -- KN -- 440 480 500 550 600 B -- M C -- N B -- -- C KB -- -- -- -- Rockwell Automation Publication 700-TD552F-EN-P - January 2021 191 Relay and Timer Specifications Assignment of Contacts Device Combinations in Accordance with IEC 60947-1 / -4-1 Auxiliary Contact Blocks Circuit Diagram Control FrontMounting (1) 100-FA02 51 61 52 62 100-FA11 53 61 54 62 100-FA20 53 63 54 64 100-FA22 53 61 71 83 54 62 72 84 100-FA31 53 61 73 83 54 62 74 84 100-FA40 53 63 73 83 54 64 74 84 100-FAL22 53 61 75 87 54 62 76 88 (1) Control relay and auxiliary contact block AC/DC max. 4 N. C. AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC Control Relays 700-CF (AC and DC Control) 700-CF220 700-CF310 700-CF400 22E + 02E = 24Y 22E + 11E = 33Y 22E + 20E = 42Y 22E + 22E = 44Y 22E + 31E = 53Y 22E + 40E = 62Y 22E + L22E = L44Y 31E + 02E = 33Y 31E + 11E = 42Y 31E + 20E = 51Y 31E + 22E = 53Y 31E + 31E = 62Y 31E + 40E = 71Y 31E + L22E = L53Y 40E + 02E = 42Y 40E + 11E = 51Y 40E + 20E = 60Y 40E + 22E = 62Y 40E + 31E = 71Y 40E + 40E = 80Y 40E + L22E = L62Y 192 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Auxiliary Contacts Photo Description N.O. N.C. Connection Diagrams 0 2 1 1 Auxiliary Contact Blocks for Front 2 0 Mounting§ 2- and 4-pole 1L 1L Quick and easy mounting without tools 0 4 Electronic-compatible contacts down to 17V, 5 mA Mechanically linked performance 1 3 between N.O. and N.C. poles and to the 2 2 main relay poles (except for L types) Models with equal function with several 3 1 terminal numbering choices 1L = Late break N.C./early make N.O. 4 0 Bifurcated version for switching down to 5V, 3 mA 1+1L 1+1L For Use With Standard Contacts (1) Cat. No. 100-FA02 100-FA11 100-FA20 100-FAL11 100-FA04 100-FA13 700-CF 100-FA22 100-FA31 100-FA40 Bifurcated Contacts Cat. No. 100-FAB02 100-FAB11 100-FAB20 -- 100-FAB04 100-FAB13 100-FAB22 100-FAB31 100-FAB40 100-FAL22 -- (1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFA02. Photo Description N.O. N.C. Connection Diagrams 0 1 1 0 0 2 1 1 Auxiliary Contact Blocks for Side Mounting without 2 0 Sequence Terminal Designations§ 1- and 2-pole Two-way numbering for right or left mounting on the contactor Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 10 mA Mirror contact performance to the main relay poles 1L = Late break N.C./early make N.O. 1L 1L For Use With Cat. No. 100-SA01 100-SA10 100-SA02 100-SA11 100-SA20 700-CF 100-SAL11 IMPORTANT For maximum number of contacts, see the following tables. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 193 Relay and Timer Specifications 700-CF (AC electronic coils), vertical mounting, 60 °C(1) Cat. No. 700... Max. N.O. Side Aux. Max. N.C. Side Aux. Max. N.O. Front Aux. Max. N.C. Front Aux. CF400 2 4 4 4 CF310 2 4 (2) 4 4(3) CF220 4 4 (2) 4 2 CF040 2 2 4 0 (1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. (2) With no front auxiliary contacts installed. Otherwise 3 N.C. Maximum (3) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum Max. N.O. Front + Side Aux. 6 6 8 6 Max. N.C. Front + Side Aux. 7 5 5 2 Max. N.O. + N.C. Front + Side Aux. 8 8 8 6 700-CF (DC conventional coils), vertical mounting, 60 °C(1) Cat. No. 700... Max. N.O. Side Aux. Max. N.C. Side Aux. Max. N.O. Front Aux. Max. N.C. Front Aux. CF400 2 2 4 4 (2) CF310 2 2 4 4 (2) CF220 2 2 4 2 (1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. (2) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum Max. N.O. Front + Side Aux. 6 6 6 Max. N.C. Front + Side Aux. 5 5 4 Max. N.O. + N.C. Front + Side Aux. 8 8 8 194 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Control Modules Photo Description Connection Diagrams Pneumatic Timing Modules(1) ON-Delay Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay. Pneumatic Timing Modules OFF-Delay Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay. Electronic Timing Modules -- On-Delay Delay of the control relay coil assembly. The control relay is energized at the end of the delay time. Electronic Timing Modules -- Off-Delay Delay of the control relay coil assembly. After interruption of the control signal, the control relay is deenergized at the end of the delay time. (1) On-Delay modules cannot be used with side-mounted auxiliary contacts on DC coil relays. Photo Description Reset Repeat Time Accuracy Delay For Use With 0.3...30 s Cat. No. 100-FPTA30 25...90 ms for AC Coils 47...85 ms for DC coils +/-10% 1.8...180 s 700-CF all (1) 0.3...30 s 100-FPTA180 100-FPTB30 1.8...180 s 100-FPTB180 100 ms +/-1% 100 ms +/-1% 0.1...3 s 1...30 s 10...180 s 0.1...3 s 1...30 s 10...180 s 700-CF 110...240V AC coils 700-CF 24...48V DC coils 0.3...3 s 1...30 s 10...180 s 0.3...3 s 1...30 s 10...180 s 700-CF 110...240V AC coils 700-CF 24V AC coils 100-ETA3 100-ETA30 100-ETA180 100-ETAZJ3 100-ETAZJ30 100-ETAZJ180 100-ETB3 100-ETB30 100-ETB180 100-ETBKJ3 100-ETBKJ30 100-ETBKJ180 Connection Diagrams For Use With Cat. No. Mechanical Latch Following relay latching, the relay coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66). Electrical or manual release 1 N.O. + 1 N.C. auxiliary contacts 700-CF with AC coils 100-FL11 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 195 Relay and Timer Specifications Photo Description Connection Diagrams RC Module AC Operating Mechanism 24...48V 50/60 Hz 110...280V 50/60 Hz 380...480V 50/60 Hz Surge Suppressors For limitation of coil switching transients. Plug-in, coil mounted Varistor Module AC/DC Operating Mechanism 12...55V AC/ 12...77V DC 56...136V AC/ 78...180V DC 137...277V AC/ 181...350V DC 278...575V AC Diode Module DC Operating Mechanism Dropout Time 70...95 ms 12...250V DC (1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFSC48. Coil Voltage Code For Use With 700-CF with AC coils 700-CF all Cat. No. (1) 100-FSC48 100-FSC280 100-FSC480 100-FSV55 100-FSV136 100-FSV277 100-FSV575 700-CF with Conventional DC coils 100-FSD250 The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 100-FL11 becomes Cat. No. 100-FL11J. [V] (1) 24 48 100 110 120 230...240 240 277 380...400 400...415 440 480 50 Hz K Y KP D -- VA T -- N G B -- 60 Hz J -- -- -- D -- A T -- -- N B (1) For special voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. Photo Description (Relays) DC Interface (electronic) Interface between the DC control signal (PLC) and the AC operating mechanism of the control relay. Control (input) voltage 12V DC 24V DC 48V DC Requires no additional surge suppression on the relay coils Input: 24V DC Output: 110...240V AC Input: 12V DC Output: 110...240V AC Input: 48V DC Output: 110...240V AC Connection Diagrams For Use With (Relays) Cat. No. 100-JE 700-CF with 110...240V AC coils 100-JE12 100-JE48 196 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications 100-J... DC Interfaces Electrical Input Voltage Input Voltage Range Output Voltage Power Consumption Minimum Actuation Mechanical Finger Protection Pickup Time Dropout Time Max. Cycles Per Second Isolation/Breakdown Voltage Rated Impulse Withstand Voltage Environmental Ambient Temperature Range Storage Temperature Range Operating Life Construction Flexible wire Wire Size Range Solid wire Solid and Stranded Tightening Torque Type of Light (1) To consider the maximum operations/hour of the relays. 1 Wire 2 Wire 1 Wire 2 Wire Assembly Components Photo Description Cat. No. 100-JE Cat. No. 100-JE12 Cat. No. 100-JE48 24V DC 18...30V DC 110...240V AC 0.1...0.4 W 5V DC, 2 mA DC 12V DC 6...12V DC 110...240V AC 0.02...0.12 W 5V DC, 2 mA DC 48V DC 35...48V DC 110...240V AC 0.2...0.5 W 5V DC, 2 mA DC IP20 0...10 ms + pickup time of the contactor 0...10 ms + dropout time of the contactor 2 (1) In: 50V, Out: 250V 4 kV IP20 0...10 ms + pickup time of the contactor 0...10 ms + dropout time of the contactor 2 (1) In: 50V, Out: 250V 4 kV IP20 0...10 ms + pickup time of the contactor 0...10 ms + dropout time of the contactor 2 (1) In: 50V, Out: 250V 4 kV -25...+60 °C -50...+80 °C 100 + million ops -25...+60 °C -50...+80 °C 100 + million ops -25...+60 °C -50...+80 °C 100 + million ops 0.5...2.5 mm2 0.75...2.5 mm2 1.0...2.5 mm2 1.0...2.5 mm2 18...14 AWG 1...1.5 N·m / 7...15 lb·in LED 0.5...2.5 mm2 0.75...2.5 mm2 1.0...2.5 mm2 1.0...2.5 mm2 18...14 AWG 1...1.5 N·m / 7...15 lb·in LED 0.5...2.5 mm2 0.75...2.5 mm2 1.0...2.5 mm2 1.0...2.5 mm2 18...14 AWG 1...1.5 N·m / 7...15 lb·in LED For Use With Pkg Qty. (1) Cat. No. Protective Covers Provides protection against unintended manual operation 700-CF all 1 100-SCCA Protective Covers · Provides protection against unintended manual operation · For contactors and front-mounted auxiliary contacts, pneumatic timers, and latches (1) All Cat. Nos. are factory stocked. 100-FA, -FB, -FC, -FP, -FL; 10 100-SCFA Rockwell Automation Publication 700-TD552F-EN-P - January 2021 197 Relay and Timer Specifications Accessories Uniform labeling materials for contactors, motor startup equipment, relays, and circuit breakers. Photo Description Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover Transparent Cover To be used with marking tag sheets Marking Tag Adapters To be used with marking tag: System V4/V5 System 1492 W (1) Must be ordered in multiples of package quantities. (2) Marker for 100-FMA1 must be purchased from a third party. Pkg. Qty. (1) 10 Cat. No. 100-FMS 10 100-FMP 100 100-FMC 100 100-FMA1 (2) 100-FMA2 198 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Coils Photo Relay and Timer Specifications AC Coil Code Q R J K KJ V W X Y KY KP D KD P S KG H L KL A F KF VA T KA I E N KN G B KB M C 50Hz -- 12V -- 24V -- 32V 36V 42V 48V -- 100V 110V -- 120V 127V 200V -- 200 - 220V -- 220V 220 - 230V -- 230 - 240V 240V -- -- -- 380 - 400V -- 400-415V 440V -- 500V 550V AC Voltages 60Hz 12V -- 24V -- -- 36V -- 48V -- -- 100 - 110V 120V -- -- -- 200 - 220V 208V 208 - 240V -- 240V 260V -- -- 277V -- 347V 380V 440V -- -- 480V -- -- 600V 50/60Hz -- -- -- -- 24V -- -- -- -- 48V 100V -- 110V -- -- 200V -- -- 200 - 230V -- -- 230V -- -- 240V -- -- -- 400V -- -- 440V -- -- Cat. No. 700-CF TA006 TA404 TA013 TA407 TA855 TA481 TA410 TA482 TA414 TA860 TA861 TA473 TA856 TA425 TA428 TA862 TA049 TA296 TA864 TA474 TA441 TA851 TA440 TA480 TA858 TA065 TA067 TA071 TA863 TA457 TA475 TA859 TA479 TA476 DC Coil Code DC Voltages Cat. No. 700-CF EQ 12V TC708E EJ 24 V TC714E QJ 24V TC714Q EY 48...72V TC724E EW 36...48 TC719E ED 110...125 TC733E EA 220...250 TC747E Rockwell Automation Publication 700-TD552F-EN-P - January 2021 199 Relay and Timer Specifications Specifications - 700-CF..., 700S-CF Relays Contact Ratings -- NEMA Min. Contact Rating Contact Ratings -- IEC AC-15 (solenoids, contactors) at rated voltage IEC 60947-5-1 40 °C AC-12 (Control of resistive loads) IEC 60947-5-1 60 °C DC-12 Switching DC Loads L/R < 1ms, Resistive Loads IEC 60947-5-1 DC-13 IEC 60947-5-1, Solenoids and contactors 24V 48V 120V 240V 400V 480V/500V 600V 690V Ith 230V 400V 690V Ith 230V 400V 690V 24V 48V 110V 220V 440V 24V 48V 110V 220V 440V Main Relay Cat. Nos. 700-CF, 700S- CF A600, P600 17V, 10 mA 10 A 10 A 10 A 10 A 6 A 2.5 A 1 A 1 A 20 A 8 kW 14 kW 24 kW 20 A 8 kW 14 kW 24 kW 15 A 10 A 6 A 1 A 0.4 A 5 A 3 A 1.2 A 0.6 A 0.3 A Front Mounted Standard Auxiliary Contacts A600, Q600 17V, 5 mA 6 A 6 A 6 A 5 A 3 A 1.6 A 1 A 1 A 10 A 6 A 10 A 9 A 3.5 A 0.7 A 0.2 A 5 A 3 A 1.2 A 0.6 A 0.15 A Main Relay Cat. No. 700-CFB, 700S- CFB A600, Q600 8V, 5 mA 3 A 3 A 3 A 3 A 2 A 1.2 A 0.7 A 0.7 A 10 A 6 A 6 A 3.2 A 1 A 0.5 A 0.2 A 2.5 A 1.5 A 0.6 A 0.3 A 0.15 A Master Relay Cat. No. 700-CFM 2 x A600, P600 -- 15 A 15 A 15 A 15 A 7.5 A 5 A 2 A 2 A Front Mounted Bifurcated Auxiliary Contacts A600, Q600 5V, 3 mA 3 A 3 A 3 A 3 A 2 A 1.2 A 0.7 A 0.7 A Side-mounted Auxiliary Contacts A600, Q600 17V, 10 mA 6 A 6 A 6 A 5 A 3 A 1.6 A 1 A 1 A 20 A 10 A 10 A 20 A 6 A 6 A 20 A 6 A 6 A 20 A 3.2 A 3.2 A 8 A 1 A 1 A 1.5 A 0.5 A 0.5 A 0.4 A 0.2 A 0.2 A 5 A 2.5 A 5 A 3 A 1.5 A 2.5 A 1.2 A 0.6 A 0.68 A 0.6 A 0.3 A 0.32 A 0.3 A 0.15 A 0.15 A Location of welded N.O. contacts State of N.C. Contacts if N.O. contact welds Main Front aux. Main Open Open Mechanically Linked Contacts (1) Front aux. Open Open (1) Side mounted auxiliary contacts provide"mirror contact"performance with main poles only. (2) Defined in IEC 60947-5-1 annex L. Mechanically linked is a relationship between contacts of opposite types (i.e., N.O. and N.C.). Side aux. Open (2) -- 200 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Attribute Mechanical Life Electrical Life Weight Terminal Cross-Sections AC-15 (240V, 3 A) AC Coil Terminal Type Terminal Size per IEC60 947-1 Solid/Stranded (1) 1 Conductor 2 Conductor Max. Wire Size per UL/CSA Tightening Torque Tightening Torque (1) For 16 or more strands, end ferrule is required. Cat. No. 700-CF [Mil] 15 Aux./Pneumatic Timer Contact (Front mounted) 5 [Mil] 1.5 1.5 [g] 390 -- [mm2] [mm2] [AWG] [lb·in] [N·m] 2 x A4 1.5...6 1.5...6 16...10 13.3...17.7 1.5...2.0 2 x A4 0.5...2.5 0.75...2.5 18...14 8.9...13.3 1...1.5 DC Switching Ratings for 700-CF Main Poles in Series (Resistive Load at 60 °C) Attribute 1 pole 2 poles 3 poles 24/48V 15/10 A 25 A 25 A 125V 6 A 25 A 25 A 220V 1 A 6 A 25 A 440V 0.4 A 1 A 3 A Relay and Timer Specifications Rockwell Automation Publication 700-TD552F-EN-P - January 2021 201 Relay and Timer Specifications Control Circuit Operating Voltage AC 50/60 Hz DC (conventional) (1) DC (electronic EQ, EW) DC (electronic EY) DC (electronic ED) DC (electronic EA) Coil Consumption AC 50/60 Hz DC (conventional) DC (electronic EQ, EJ) DC (electronic EY) DC (electronic ED) DC (electronic EA) Operating Times AC 50/60 Hz DC (conventional) With integrated diode With external diode DC (electronic- EQ, EJ) DC (electronic - EW EY, ED, EA) DC (electronic- QJ) Attribute Pickup Dropout Pickup Dropout Pickup Dropout Pickup Dropout Pickup Dropout Pickup Dropout Inrush Sealed Inrush Sealed Inrush (avg./ peak) Sealed Inrush (avg./ peak) Sealed Inrush (avg./ peak) Sealed Inrush (avg./ peak) Sealed Pickup Time Dropout Time Pickup Time Dropout Time Opening Delay Opening Delay Closing Delay Opening Delay Closing Delay Opening Delay Closing Delay Opening Delay [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [VA] [VA/W] [W] [W] [W] [W] [W] [W] [W] [W] [W] [W] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] Cat. No. 700-CF 0.85...1.1 0.3...0.6 0.8...1.1 0.1...0.6 0.7...1.25 0.3...0.4 0.8...1.25 0.3...0.4 0.7...1.12 (2) 0.3...0.4 0.8...1.1 0.3...0.4 75 9.5/2.7 7.7 6.3 10/17 1.7 10/17 1.9 12/19 2.1 14/22 3.0 15...30 10...60 40...70 7...15 14...20 70...125 25...50 27...45 25...50 23...33 20...50 15...22 202 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Attribute Min OFF time Max. ripple Latch Attachment Release, 100-FL AC Coil Consumption DC Contact Signal Duration Timing Attachment Reset Time, 100- ETA, 100-ETB at min. time setting at max. time setting Repeat Accuracy (1) For 9V DC, code ZR, use operating voltage 0.65...1.3 x Us. For 24V DC, code ZJ, DJ, or EJ use operating voltage 0.7...1.25 x Us. (2) At 110V DC, coil code ED has an operating voltage range of 0.7...1.25 x Us. [ms] [VA/W] [W] [min./max] [ms] [ms] Cat. No. 700-CF 50 ± 15% 45/40 25 0.03...15 s 10 70 ± 10% Relay and Timer Specifications Rockwell Automation Publication 700-TD552F-EN-P - January 2021 203 Relay and Timer Specifications General Specifications - 700-CF Relays Rated Insulation Voltage Ui IEC UL; CSA Rated Impulse Strength Uimp High Test Voltage 1 minute (per IEC 60947Rated Voltage Ue AC DC Rated Frequency Ambient Temperature Storage Operation at nominal current 15% current reduction for AC-12 at > 60 °C Corrosion Resistance Altitude Type of Protection IP2X (IEC 60529 and DIN 40050) Shock Resistance Vibration Resistance Standards Compliance Certifications Cat. No. 700-CF 690V 600V 6 kV 2500V 115, 230, 400, 500, 690V 24, 48, 110, 220, 440V Short-Circuit Protection gG Fuse 20 A 50/60 Hz, DC 55...+80 °C (67...+176 °F) 25...+60 °C (13...+140 °F) 25...+70 °C (13...+158 °F) humid-alternating climate, cyclic, per IEC 60068-2-30 and DIN 50 016, 56 cycles 2000 m above mean sea level, per IEC 60 947-4 in connected state IEC 60068-2: Half sinusoidal shock 11 ms, 30 G (in 3 directions) IEC 60068-2: Static >2 G, in normal position no malfunction <5 G UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for European Directive 2002/95/EC - EUcULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, CCC Certified Utilization Category Table from EN 60947-5-1 Verification of Making and Breaking Capacities of Switching Elements Under Normal Conditions Corresponding to the Utilization Categories (1) Normal Condition of Use Utilization Category AC-12 (2) AC-13 (2) AC-14 (2) AC-15 (2) Make (3) I/Ie 1 2 6 10 U/Ue 1 1 1 1 Break (3) cos 0.9 0.65 0.3 0.3 I/Ie 1 1 1 1 U/Ue 1 1 1 1 cos 0.9 0.65 0.3 0.3 Number and Rate of Making and Breaking operations No. operating cycles (5) Operating cycles per minute ON time [s] (6) 6050 6 0.05 6050 6 0.05 6050 6 0.05 6050 6 0.05 DC -- -- T0.95 -- -- T0.95 -- -- -- DC-12 1 1 1 ms 1 1 1 ms 6050 6 0.05 (6) DC-13 1 1 6 x P (4) 1 1 6 x P (4) 6050 6 0.05 (6) DC-14 (2) 10 1 15 ms 1 1 15 ms 6050 -- 0.05 (6) (1) See sub-clause 8.3.3.5.2. (2) Where the break current differs from the make current value, the ON time refers to the make current value after which the current is reduced to the break current value for a suitable period e.g., 0.05 s. (3) For tolerances on test quantities, see sub-clause 8.3.2.2. (4) The value "6 x P"results from an empirical relationship which is found to represent most DC magnetic loads to an upper limit of P = 50 W, e.g., 6 x P = 300 W. (5) The first 50 operating cycles shall be run at U/Ue = 1.1 with the loads set at Ue. (6) The ON time shall be at least equal to T0.95. Ie Rated operational current, I Current to be made or broken Ue Rated operational voltage, U Voltage before make PUeIe Steady-state power consumption (W) T0.95 Time to reach 95% of the steady-state current (ms) 204 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Contact Rating Table from EN 60947-5-1 Examples of Contact Rating Designation Based on Utilization Categories NEMA Designation (1) IEC Utilization Category Conventional Thermal Current Ithe (A) Rated Operational Current Ie (A) at Rated Operational Voltage Ue AC 120V 240V 380V 480V 500V 600V A150 AC-15 10 6 -- -- -- -- -- A300 AC-15 10 6 3 -- -- -- -- A600 AC-15 10 6 3 1.9 1.5 1.4 1.2 B150 AC-15 5 3 -- -- -- -- -- B300 AC-15 5 3 1.5 -- -- -- -- B600 AC-15 5 3 1.5 0.95 0.75 0.72 0.6 C150 AC-15 2.5 1.5 -- -- -- -- -- C300 AC-15 2.5 1.5 0.75 -- -- -- -- C600 AC-15 2.5 1.5 0.75 0.47 0.375 .035 0.3 D150 AC-15 1.0 0.6 -- -- -- -- -- D300 AC-14 1.0 0.6 0.3 -- -- -- -- E150 AC-14 0.5 0.3 -- -- -- -- -- DC 125V 250V 440V 500V 600V -- N150 DC-13 10 2.2 -- -- -- -- -- N300 DC-13 10 2.2 1.1 -- -- -- -- N600 DC-13 10 2.2 1.1 0.63 0.55 0.4 -- P150 DC-13 5 1.1 -- -- -- -- -- P300 DC-13 5 1.1 0.55 -- -- -- -- P600 DC-13 5 1.1 0.55 0.31 0.27 0.2 -- Q150 DC-13 2.5 0.55 -- -- -- -- -- Q300 DC-13 2.5 0.55 0.27 -- -- -- -- Q600 DC-13 2.5 0.55 0.27 0.15 0.13 0.1 -- R150 DC-13 1.0 0.22 -- -- -- -- -- R300 DC-13 1.0 0.22 0.1 -- -- -- -- (1) This letter stands for the conventional thermal current and identifies AC or DC: for example, B=5 A AC. The number that follows is the rated insulation voltage. VA Rating Make Break 7200 720 7200 720 7200 720 3600 360 3600 360 3600 360 1800 180 1800 180 1800 180 432 72 432 72 216 36 Make Break 275 275 275 275 275 275 138 138 138 138 138 138 69 69 69 69 69 69 28 28 28 28 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 205 Relay and Timer Specifications Dimensions - 700-CF... Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Mounting Position AC and DC Control Relay with DC Electronic Coil (1) (1) May be mounted to 35 mm EN 50 022 DIN Rail. Front View Side View DC Control Relay Front View Side View All AC Control Relays and DC Control Relays with 12V or 24V DC Electronic Coil Type 700-CF, -CFB, -CFM a 45 (1-25/32) b 81 (3-3/16) c 80.5 (3-11/64) c1 75.5 (3-3/32) c2 6 (1/4) Ød 2 screws 4.5 (3/16) d1 60 (2-23/64) d2 35 (1-25/64) DC Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil Type 700-CF, -CFB, -CFM a 45 (1-25/32) b 105 (4-1/8) c 80.5 (3-11/64) c1 75.5 (3-3/32) c2 6 (1/4) Ød 2 screws 4.5 (3/16) d1 60 (2-23/64) d2 35 (1-25/64) DC Control Relays with Conventional Coil Type 700-CF, -CFB, -CFM a 45 (1-25/32) b 81 (3-3/16) c 106.5 (4-3/16) c1 101.5 (4) c2 6 (1/4) Ød 2 screws 4.5 (3/16) d1 60 (2-23/64) d2 35 (1-25/64) 206 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Accessories - 700-CF Relays Relay with Auxiliary Contact for Front Mounting Auxiliary Contact for Side Mounting Pneumatic Timing Module Solid-state Timing Module Mechanical Latching DC Interface Surge Suppressor Labelling with: -- -- -- 2- or 4-pole 1- or 2-pole -- on coil terminal side -- on coil terminal side on coil terminal side label sheet marking tag with cover marking tag carrier for System V4/V5 marking tag carrier for System Bull. 1492W AC Control Relay mm (inches) c/c1 + 39 (c/c1 + 1 37/64) a + 9 (a + 23/64) c/c1 + 58 (c/c1 + 2 23/64) b + 24 (b + 15/16) c/c1 + 61 (c/c1 + 2 31/64) b + 9 (b + 23/64) b + 3 (b + 1/8) +0 (+0) +0 (+0) +5.5 (+7/32) +5.5 (+7/32) DC Control Relay mm (inches) c/c1 + 39 c/c1 + 1 37/64) a + 9 (a + 23/64) -- -- b + 24 (b + 15/16) -- -- -- -- b + 3 (b + 1/8) +0 (+0) +0 (+0) +5.5 (+7/32) +5.5 (+7/32) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 207 Relay and Timer Specifications 700S-CF Control Relays The 700S-CF Safety Control Relay provides mechanically or mirror contact performance, which are required in feedback circuits for safety applications. Bifurcated contacts are ideal for low energy feedback safety circuits where high contact reliability is required. · IEC industrial safety relay · Mechanically linked contacts as per IEC 60947-5-1 · Third party certification SUVA · Red cover and mechanically linked contact symbol on front face · Gold plated, bifurcated version for low level switching applications · Permanently fixed front mounted auxiliary contact block Type CF and CFB Safety Control Relays -- 8-Pole AC Coil Voltage (Ratings for 700S-CF Only) AC-12 AC-15 Connection Diagrams Ith [A] Ie [A] 40 60 24/ °C °C 48V 20 20 10 Main Contacts 120 240 400 500 600 690 V V V V V V 10 10 6 2.5 1 1 Main Contacts Auxiliary Contacts Contacts Standard Contacts (Main) Gold-Plated Bifurcated (Front) Cat. No. Gold-Plated Bifurcated, All Contacts Cat. No. (1) N.O. N.C. 4 4 700S- 700S- CF440BC CFB440C 5 3 700S- 700S- CF530BC CFB530C Adder 10 6 6 Deck Contacts 6 5 3 1.6 1 1 (1) Ratings for 700S-CFB are on Specifications 6 2 700S- 700S- CF620BC CFB620C AC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CF440BC becomes Cat. No. 700S-CF440DBC for 120V, 60 Hz. [V] 12 24 50 Hz R K 60 Hz Q J 50/60 -- KJ Hz 32 36 42 48 V W X Y -- V -- X -- -- -- KY 100 100... 110 120 127 200 200... 208 208... 220... 110 220 240 230 KP -- D P S KG L -- -- F -- KP -- D -- -- KG H L -- KP -- KD -- -- KG KL -- -- KL [V] 230 230... 240 277 347 380 380... 400 400... 440 480 500 550 600 240 400 415 50 Hz -- VA T -- -- -- N -- G B -- M C -- 60 Hz -- -- A T I E -- -- -- N B -- -- C 50/60 Hz KF -- KA -- -- -- -- KN -- KB -- -- -- -- 208 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Type CF and CFB Safety Control Relays -- 8-Pole DC Coil Voltage (Ratings for 700S-CF Only) AC-12 Ith [A] AC-15 Ie [A] Connection Diagrams Main Contacts 40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V 20 20 10 10 10 6 2.5 1 1 Main Contacts Auxiliary Contacts Contacts No. of N.O. Contacts No. of N.C. Contacts Standard Contacts (Main) GoldPlated Bifurcated (Front) Cat. No. Gold Plated Bifurcated All Contacts Cat. No.(1) 4 4 700S- 700S- CF440BC CFB440C 5 3 700S- 700S- CF530BC CFB530C Adder 10 6 6 Deck Contacts 6 5 3 1.6 1 1 (1) Ratings for 700S-CFB are on Specifications 6 2 700S- 700S- CF620BC CFB620C DC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CFB440C becomes Cat. No. 700S-CFB440EJC for 24V DC, electronic with diode. [V] 9 12 24 Electronic with diode -- EQ EJ Electronic with diode/ Quick -- -- QJ Pick-up 36 48 48... 72 60 64 72 80 110 110... 125 115 125 220 220... 250 230 250 EW -- EY -- -- -- -- -- ED -- -- -- EA -- -- ------------------ -------- ---- Rockwell Automation Publication 700-TD552F-EN-P - January 2021 209 Relay and Timer Specifications Assignment of Contacts Safety Control Relays with Front-mount Auxiliary Contacts, 8-Pole AC or DC Coil Voltage 53 61 71 81 53 61 71 83 53 61 73 83 54 62 72 82 A1 13 21 33 43 K1 A2 14 22 34 44 700S-CF440... 700S-CFB440... 54 62 72 84 A1 13 21 33 43 K1 A2 14 22 34 44 700S-CF530... 700S-CFB530... 54 62 74 84 A1 13 21 33 43 K1 A2 14 22 34 44 700S-CF620... 700S-CFB620... Specifications - 700S-CF Relays For more 700S-CF Specifications, see Specifications - 700-CF..., 700S-CF Relays on page 200. Mechanical Life Electrical Life Weight Terminal Cross-Sections Terminal Type Terminal Size per IEC 947-1 Solid/ Stranded (1) Max. Wire Size per UL/CSA Tightening Torque Tightening Torque AC-15 (240V, 3 A) AC Coil 1 Conductor 2 Conductor Standards Compliance Certifications (1) For 16 or more strands, end ferrule is required [Mil] [Mil] [g] [mm2] [mm2] [AWG] [lb·in] [N·m] Cat. No. 700S-CF 15 1.5 390 Aux. Contact (Front-mounted) 15 1.5 -- 2 x A4 2 x A4 1.5...6 0.5...2.5 1.5...6 0.75...2.5 16...10 18...14 13.3...22 8.9...13.3 1.5...2.5 1...1.5 UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for European Directive 2002/95/EC - EU-RoHS cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, CCC Certified 210 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Dimensions - 700S-CF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. c2 AC and DC Safety Control Relays with 12V or 24V DC Electronic Coil Cat. No. 700S-CF a 45 (1-25/32) b 81 (3-3/16) c 119.5 (4-3/4) c1 114.5 (4-43/64) c1 c c2 6 (1/4) DC Safety Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil Cat. No. 700S-CF a 45 (1-25/32) b 105 (4-1/8) c 119.5 (4-3/4) c1 114.5 (4-43/64) c2 6 (1/4) DC Safety Control Relays with Conventional Coil Cat. No. 700S-CF a 45 (1-25/32) b 81 (3-3/16) c 145.5 (5-49/64) c1 140.5 (5-37/64) c2 6 (1/4) Accessories - 700S-CF Relays Safety Control Relays with Auxiliary contact block for side mounting 1- or 2-pole Electronic Timing Module on coil terminal side Interface Module on coil terminal side Surge Suppressor on coil terminal side Labeling with label sheet Marking tag sheet with clear cover Marking tag adapter for System Bul. 1492W Ød 2 - 4.5 (2 - 3/16) d1 60 (2-23/64) d2 35 (1-25/64) Ød 2 - 4.5 (2 - 3/16) d1 60 (2-23/64) d2 35 (1-25/64) Ød 2 - 4.5 (2 - 3/16) d1 60 (2-23/64) d2 35 (1-25/64) mm a + 9 b + 24 b + 9 b + 3 + 0 + 0 + 5.5 [in.] (a + 23/64) (b + 15/16) (b + 23/64) (b + 1/8) (+ 0) (+ 0) (+ 7/32) Mounting Position AC and DC E Safety Control Relays DC Safety Control Relays Front View Side View Front View Side View Rockwell Automation Publication 700-TD552F-EN-P - January 2021 211 Relay and Timer Specifications Safety Relay Circuit With 5 Safety Outputs · Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open connection such as a loose wire). · High output switching capability and long contact life. · Circuit complies with EN 954 categories 1, 2, 3, 4. · Helps prevent restart of the 5 safety outputs if there is a single fault anywhere in the system. · Use (3) 700S-CF relays and this diagram to construct the circuit Basic Circuit (1) Output Circuit (3 Relays, 9 Terminal Blocks) Start Push To Stop Pull To Reset Included in factory wired units LOAD 1 (5) Output Circuit (3 Relays, 17 Terminal Blocks) LOAD 2 LOAD 3 LOAD 4 LOAD 5 * Numbers shown are the line numbers where the contacts for this relay appear. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability. 212 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-EF Control Relay · IEC industrial relays · Electronic coils · Mechanically linked contact performance per IEC 60947-5-1 · Wide control voltage range · Built-in surge protection · Add-on auxiliary contact blocks - front or side mount 4-Pole AC Coil Voltage AC-12 AC-15 Ith [A] Ie [A] Connection Diagrams 40 °C 24/48V 120V 240V 400V 500V 690V Contacts Standard Contacts(1) N.O. N.C. Cat. No. 2 2 700-EF220 16 6 6 4 3 2 2 (1) All catalog numbers are factory stocked. 3 1 700-EF310 4 0 700-EF400 Voltage Codes. The catalog number listed is incomplete. Select a coil voltage from the table below to complete the catalog number. Example 700-EF220KJ. Voltage(1) 12...20V DC 24V DC 24...60V AC 20...60V DC 48...130V AC/DC 100...250V AC/DC 250...500V AC/DC Standard AC/DC -- -- KJ KY KD KN Low Consumption AC/DC EQ -- EJ -- -- -- Low Consumption/Faster Drop-out DC -- QJ -- -- -- -- (1) AC Voltages are a 50/60 Hz. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 213 Relay and Timer Specifications Accessories Auxiliary Contact Blocks with Standard Auxiliary Contacts Description Auxiliary Contact Blocks for Front Mounting · 1-pole · Quick and easy mounting without tools · Screw connection terminals · Switching down to 12V, 3mA · Mirror contact performance to the main relay poles · L= Late break N.C./early make N.O. Auxiliary Contact Blocks for Front Mounting · 4-pole · Quick and easy mounting without tools · Screw connection terminals · Switching down to 12V 3mA · Mirror contact performance to the main relay poles Connection Diagrams N.O. N.C. 10 -3 -1 NO NC 01 -4 -2 1L 0 -7 -5 NO NC 0 1L -8 -6 53 61 71 83 2 2 NO NC NC NO 54 62 72 84 53 61 73 83 3 1 NO NC NO NO 54 62 74 84 53 63 73 83 4 0 NO NO NO NO 54 64 74 84 53 61 71 81 1 3 NO NC NC NC 54 62 72 82 51 61 71 81 0 4 NC NC NC NC 52 62 72 82 Auxiliary Contact Blocks for Side Mounting · 2-pole · Two-way numbering for right or left mounting on the relay · With or without sequence terminal designations · Quick and easy mounting without tools · Screw connecting terminals · Switching down to 12V, 3mA · Mirror contact performance to the main relay poles 11 -3 -1 NO NC -4 -2 For Use With 700-EF220 700-EF310 700-EF220 700-EF310 700-EF220 700-EF220 700-EF310 Cat. No. 100-EFA10 100-EFA01 100-EFAL10 100-EFAL01 100-EFA22 100-EFA31 100-EFA40 100-EFA13 100-EFA04 100-ESA11 Electronic Timers Description Electronic Timing Module--ON-Delay · Delay of the relay solenoid · The relay is energized at the end of the delay time Electronic Timing Module--OFF-Delay · Delay of the relay solenoid · After interruption of the control signal, the relay is de- energized a the end of the delay time ON-Delay 0.1...1 s 1...10 s 10...100 s OFF-Delay 0.1...1 s 1...10 s 10...100 s N.O. N.C. 11 11 Connection Diagrams 55NC 67NO A1 KM1 A2 56NC 68NO 55NC 67NO A1 KM1 A2 56NC 68NO For Use With 700-EF220 700-EF310 700-EF220 700-EF310 Cat. No. 100-ETA 100-ETB 214 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications DC Interface Module Description DC Interface · Receives 24V DC signals from PLCs or other low output power sources and switches AC control power to operate the coils of the relay. · Coil voltage: 24...250V AC 50/60 Hz · Rated control circuit voltage Uc: 24VDC For Use With 700-EF Pkg. Qty. 1 10 Cat. No. 100-EJE 100-EJEM Mechanical Latch Description Mechanical Latch · Ensures contactor or relay is switched on even if there is a voltage failure · Opening controlled either electrically by AC or DC impulse or manually by button · Front mounting Rated Voltage [V] Connection V AC, 50/60 Hz V DC Diagram 24...60 24...60 48...130 48...130 100...250 100...250 A1 E1 U c E2 250...500 250...500 A2 For Use With 700-EF Additional Coil Terminal Block Description Additional Coil Terminal Block · Allows bottom access to the coil terminals in addition to top access For Use With 700-EF Pkg. Qty. 10 Cat. No. 100-EFL11EJ 100-EFL11EY 100-EFL11ED 100-EFL11EN Cat. No. 100-ECT Functional Markers Description Functional Markers · 256 markers (16 per card) printable on HTP500 thermal transfer printer and AMS 500 marking table · 7 x 20 mm (0.276 x 0.787 in) For Use With 700-EF Pkg. Qty. 16 Cat. No. 100-EFMS Rockwell Automation Publication 700-TD552F-EN-P - January 2021 215 Relay and Timer Specifications Auxiliary Contacts 700-EF Cat. No. 700... EF310 EF220 EF400 Max 2 Pole Side Aux. 1 (L) 1 (L) 1 (R) -- Max 1 Pole Front Aux. 2 4 -- Max 4 Pole Front Aux. -- 1 -- Timer 1 1 -- Mechanical Latch 1 1 -- Mechanically Linked Contacts (1) Location of welded N.O. contacts Main Front aux. State of N.C. Contacts if N.O. contact welds Main Front aux. Open Open Open Open (1) Side mounted auxiliary contacts provide"mirror contact"performance with main poles only. (2) Defined in IEC 60947-5-1 annex L. Mechanically linked is a relationship between contacts of opposite types (i.e., N.O. and N.C.). Contacts Switching of AC Loads Rated Insulation voltage Ui Rated operational voltage Ue Rated impulse withstand voltage Uimp AC-12 Ith AC-15 at rated voltage of Switching of DC Loads DC-13 switching electromagnets at Fuse gG Load Carrying Capacity per UL/CSA Rated voltage Continuous rating Switching capacity Rated voltage Continuous rating Switching capacity at 40 °C at 60 °C 24V 42/48V 120V 230V 240V 400V 415V 500V 690V 24V DC 48V DC 110V DC 220V DC 440V DC 700-EF 690V 690V 6kV [A] 16 [A] -- [A] 6 [A] 6 [A] 6 [A] 4 [A] 4 [A] 3 [A] 3 [A] 2 [A] 2 [A] 6 [A] 2.8 [A] 0.55 [A] 0.27 [A] 0.13 AC [V] 600 40 °C [A] 10 AC A 600 DC [V] 600 40 °C [A] 2.5 DC Q 600 100-EF 690V 690V 6kV 16 -- 6 6 6 4 4 3 3 2 2 6 2.8 0.55 0.27 0.13 600 10 A 600 600 2.5 Q 600 Side aux. Open (2) -- 100-ESA 690V 690V 6kV 16 -- 6 6 6 4 4 3 3 2 2 6 2.8 0.55 0.27 0.13 600 10 A 600 600 2.5 Q 600 216 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications General Specifications - 700-EF Relays Rated Insulation Voltage Ui IEC UL; CSA Rated Impulse Strength Uimp Rated Voltage Ue AC DC Rated Frequency Ambient Temperature Storage Operation at nominal current Altitude Mechanical Life Electrical Life Type of Protection IP2X (IEC 60529 and DIN 40050) Shock Resistance Vibration Resistance Standards Compliance Certifications Cat. No. 700-EF 690V 600V 6 kV 24, 48, 120, 230, 400, 500, 690V 24, 48, 110, 220, 440V Short-Circuit Protection gG Fuse 10 A 50/60 Hz, DC 60...+80 °C (76...+176 °F) 40...+70 °C (40...+158 °F) 3000 m 20 Mil 1.5 Mil (AC-15 240V, 3A) in connected state IEC 60068-2: Half sinusoidal shock 11 ms, 25G (in 3 directions) IEC 60068-2: Static >2 G, in normal position no malfunction <5 G UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, RoHS cULus Listed, CE Marked, CCC Certified Conductors Cross Sections, Screw Type Terminals 700-EF/ 700S-EF Conductor Cross Sections--Main Contacts Terminal Type 1 conductor 2 conductors 1 conductor 2 conductors [mm2] [mm2] [mm2] [mm2] Recommended torque [N·m] Cross Section per UL/CSA [AWG] Recommended torque [lb·in] Conductor Cross Sections- Coil and Auxiliary Contact Terminal Type 1 conductor 2 conductors 1 conductor 2 conductors [mm2] [mm2] [mm2] [mm2] Recommended torque [N·m] Cross Section per UL/CSA [AWG] Recommended torque [lb-in] (1) Pozidriv No. 2 / Blade No. 3 screw (1) 0.75...6 0.75...6 1...6 1...6 1.5 16...10 13 (1) 0.75...2.5 0.75...2.5 1...2.5 1...2.5 1.2 18...14 11 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 217 Relay and Timer Specifications Coil Data Operating Limits 50/60Hz DC Control Standard Coil 24-60V AC, 20-60V DC (KJ) 48...130V AC/DC (KY) 100...250V AC/DC (KD) 250...500V AC/DC (KN) Operating Times Energy-efficient Coil 12-20V DC (EQ) 24-60V AC, 20-60V DC (EJ) Operating Times High Energy Efficient Coil 24V DC (QJ) Operating Times 700-EF/ 700S-EF pick-up dropout pick-up dropout pick-up hold-in pick-up hold-in pick-up hold-in pick-up hold-in closing delay opening delay pick-up hold-in pick-up hold-in closing delay opening delay pick-up hold-in closing delay opening delay [x Us] 0.85...1.1 [x Us] 0.60 [x Us] 0.80...1.1 [x Us] 0.60 [VA]/[W] [VA]/[W] [VA]/[W] [VA]/[W] [VA]/[W] [VA]/[W] [VA]/[W] [VA]/[W] [ms] [ms] 50/50 2.2/2 50/50 2.2/2 50/50 2.2/2 50/50 2.2/2 40...95 11...95 [W] 12...16 [W] 1.7 [VA]/[W] 16/12...16 [VA]/[W] 1.7/1.7 [ms] 40...95 [ms] 11...95 [W] 6 [W] 1.7 [ms] 27...53 [ms] 17...29 218 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Contact Rating Table from EN 60947-5-1 Examples of Contact Rating Designation Based on Utilization Categories NEMA Designation (1) IEC Utilization Category Conventional Thermal Current Ithe (A) Rated Operational Current Ie (A) at Rated Operational Voltage Ue AC 120V 240V 380V 480V 500V 600V A150 AC-15 10 6 -- -- -- -- -- A300 AC-15 10 6 3 -- -- -- -- A600 AC-15 10 6 3 1.9 1.5 1.4 1.2 B150 AC-15 5 3 -- -- -- -- -- B300 AC-15 5 3 1.5 -- -- -- -- B600 AC-15 5 3 1.5 0.95 0.75 0.72 0.6 C150 AC-15 2.5 1.5 -- -- -- -- -- C300 AC-15 2.5 1.5 0.75 -- -- -- -- C600 AC-15 2.5 1.5 0.75 0.47 0.375 .035 0.3 D150 AC-15 1.0 0.6 -- -- -- -- -- D300 AC-14 1.0 0.6 0.3 -- -- -- -- E150 AC-14 0.5 0.3 -- -- -- -- -- DC 125V 250V 440V 500V 600V -- N150 DC-13 10 2.2 -- -- -- -- -- N300 DC-13 10 2.2 1.1 -- -- -- -- N600 DC-13 10 2.2 1.1 0.63 0.55 0.4 -- P150 DC-13 5 1.1 -- -- -- -- -- P300 DC-13 5 1.1 0.55 -- -- -- -- P600 DC-13 5 1.1 0.55 0.31 0.27 0.2 -- Q150 DC-13 2.5 0.55 -- -- -- -- -- Q300 DC-13 2.5 0.55 0.27 -- -- -- -- Q600 DC-13 2.5 0.55 0.27 0.15 0.13 0.1 -- R150 DC-13 1.0 0.22 -- -- -- -- -- R300 DC-13 1.0 0.22 0.1 -- -- -- -- (1) This letter stands for the conventional thermal current and identifies AC or DC: for example, B=5 A AC. The number that follows is the rated insulation voltage. VA Rating Make Break 7200 720 7200 720 7200 720 3600 360 3600 360 3600 360 1800 180 1800 180 1800 180 432 72 432 72 216 36 Make Break 275 275 275 275 275 275 138 138 138 138 138 138 69 69 69 69 69 69 28 28 28 28 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 219 Relay and Timer Specifications Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Mounting Position 700-EF Relays Position 2 +30° -30° Position 4 Position 3 Position 1 Position 1 ± 30° Position 5 700-EF Relays 700-EF Relays with Standard Coils 6 (0.24) 45 (1.77) 77 (3.03) 71 (2.80) 5.5 (0.22) 80 (3.15) 35 mm EN/IEC 60715 5.5 (0.22) 700-EF Relays with Standard Coils and Side-mounted Auxiliary Contact 12 (0.47) 45 (1.77) 6 (0.24) 77 (3.03) 71 (2.80) 5.5 (0.22) 69.4 (2.73) 80 (3.15) 35 mm EN/IEC 60715 For relays with QJ coils, add 20 mm (0.79 in.) to the depth 700-EF Relays with Low-consumption Coils 77 (3.03) 6 (0.24) 45 (1.77) 71 (2.80) 5.5 (0.22) (0 For relays with QJ coils, add 20 mm (0.79 in.) to the depth 10 (0.3 700-EF Relays with Low-consumption Coils and Front-mounted Auxiliary Contact 6 (0.24) 45 (1.77) 110.5 (4.35) 71 (2.80) 5.5 (0.22) 80 (3.15) 35 mm EN/IEC 60715 5.5 (0.22) 80 (3.15) 5.5 (0.22) (1 35 mm EN/IEC 60715 10 (0.39) For relays with QJ coils, add 20 mm (0.79 in.) to the depth 1 (0.3 For relays with QJ coils, add 20 mm (0.79 in.) to the depth 700-EF Relays with Standard Coils and Front-mounted Auxiliary Contact 6 (0.24) 45 (1.77) 110.5 (4.35) 71 (2.80) 5.5 (0.22) 700-EF Relays with Low-consumption Coils and Side-mounted Auxiliary Contact 77 (3.03) 12 (0.47) 45 (1.77) 6 (0.24) 71 (2.80) 5.5 (0.22) 69.4 (2.73) 80 (3.15) 35 mm EN/IEC 60715 80 (3.15) 5.5 (0.22) ( 35 mm EN/IEC 60715 10 (0.39) For relays with QJ coils, add 20 mm (0.79 in.) to the depth 10 (0.3 For relays with QJ coils, add 20 mm (0.79 in.) to the depth 220 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700S-EF Control Relays The 700S-EF Safety Control Relay provides mechanically or mirror contact performance, which are required in feedback circuits for safety applications. · IEC industrial safety relay · Electronic coils · Mechanically linked contacts as per IEC 60947-5-1 · Red cover and mechanically linked contact symbol on front face · Permanently fixed front mounted auxiliary contact block AC-12 AC-15 Contacts Connection Diagrams Ith [A] Ie [A] Main Contacts 40 °C 24/48V 120V 240V 400V 500V 690V 16 6 6 4 3 2 2 Main Contacts Auxiliary Contacts Standard Contacts Cat. No. N.O. N.C. 4 4 700S-EF440C 5 3 700S-EF530C Adder 16 6 Deck Contacts 6 4 3 2 2 6 2 700S-EF620C Voltage Codes The catalog number listed is incomplete. Select a coil voltage from the table below to complete the catalog number. Example 700-EF220KJ. Voltage(1) 12...20V DC 24V DC 24...60V AC 20...60V DC 48...130V AC/DC 100...250V AC/DC 250...500V AC/DC Standard AC/DC -- -- KJ KY KD KN Low Consumption AC/DC EQ -- EJ -- -- -- Low Consumption/Faster Drop-out DC -- QJ -- -- -- -- (1) AC Voltages are a 50/60 Hz. Accessories Additional Coil Terminal Block Description For Use With Pkg. Qty. Cat. No. Additional Coil Terminal Block · Allows bottom access to the coil terminals in addition to top access 700-EF 10 100-ECT Functional Markers Description For Use With Functional Markers · 256 markers (16 per card) printable on HTP500 thermal transfer printer and AMS 500 marking table · 7 x 20 mm (0.276 x 0.787 in) 700-EF Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Pkg. Qty. 16 Cat. No. 100-EFMS 221 Relay and Timer Specifications Assignment of Contacts Safety Control Relays with Front-mount Auxiliary Contacts, 8-Pole AC or DC Coil Voltage 53 61 71 81 53 61 71 83 54 62 72 82 A1 13 21 33 43 K1 A2 14 22 34 44 700S-EF440... 54 62 72 84 A1 13 21 33 43 K1 A2 14 22 34 44 700S-EF530... 53 61 73 83 54 62 74 84 A1 13 21 33 43 K1 A2 14 22 34 44 700S-EF620... Specifications - 700S-EF Relays See General Specifications - 700-EF Relays on page 217 for additional specifications. Mechanical Life Electrical Life Standards Compliance Certifications AC-15 (240V, 3 A) Cat. No. 700S-EF Aux. Contact (Front-mounted) [Mil] 20 20 [Mil] 1.5 1.5 UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for European Directive 2002/95/EC - EU-RoHS cULus Listed , CE Marked, CCC Certified Conductors Cross Sections, Screw Type Terminals 700-EF/ 700S-EF Conductor Cross Sections--Main Contacts Terminal Type 1 conductor 2 conductors 1 conductor 2 conductors [mm2] [mm2] [mm2] [mm2] Recommended torque [N·m] Cross Section per UL/CSA [AWG] Recommended torque [lb·in] Conductor Cross Sections- Coil and Auxiliary Contact Terminal Type 1 conductor 2 conductors 1 conductor 2 conductors [mm2] [mm2] [mm2] [mm2] Recommended torque [N·m] Cross Section per UL/CSA [AWG] Recommended torque [lb-in] (1) Pozidriv No. 2 / Blade No. 3 screw (1) 0.75...6 0.75...6 1...6 1...6 1.5 16...10 13 (1) 0.75...2.5 0.75...2.5 1...2.5 1...2.5 1.2 18...14 11 222 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Mounting Position for 700S-EF Relays Position 2 +30° -30° Position 4 Position 3 Position 1 Position 1 ± 30° Position 5 700S-EF Relays 700S-EF Relays with Standard Coils and Front-mounted Auxiliary Contact 6 (0.24) 45 (1.77) 110.5 (4.35) 71 (2.80) 5.5 (0.22) 80 (3.15) 35 mm EN/IEC 60715 5.5 (0.22) 43 (1.69) 10 (0.39) For relays with QJ coils, add 20 mm (0.79 in.) to the depth 700S-EF Relays with Low-consumption Coils and Front-mounted Auxiliary Contact 6 (0.24) 45 (1.77) 110.5 (4.35) 71 (2.80) 5.5 (0.22) 80 (3.15) 35 mm EN/IEC 60715 5.5 (0.22) 43 (1.69) 10 (0.39) For relays with QJ coils, add 20 mm (0.79 in.) to the depth Rockwell Automation Publication 700-TD552F-EN-P - January 2021 223 Relay and Timer Specifications Safety Relay Circuit With 5 Safety Outputs · Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open connection such as a loose wire). · High output switching capability and long contact life. · Circuit complies with EN 954 categories 1, 2, 3, 4. · Helps prevent restart of the 5 safety outputs if there is a single fault anywhere in the system. · Use (3) 700S-EF relays and this diagram to construct the circuit Start E Push To Stop Pull To Reset (5) Output Circuit (3 Relays, 17 Terminal Blocks) Included in factory wired units E E LOAD 1 LOAD 2 LOAD 3 LOAD 4 LOAD 5 224 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-K Miniature Control Relays · IEC compact industrial relay · IP2X Finger Protection · Bifurcated contacts for low-level signals · Optional integrated coil protection diode 4-Pole AC or DC Coil Voltage AC-12 AC-15 (B600) Ith [A] Ie [A] Connection Diagrams 40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V Contacts Pkg. Qty.(2) Cat. No. N.O. N.C. 4 0 1 700-K40E- 10 6 3 3 2 1 1 0.6 0.6 3 1 1 700-K31Z- 2 2 1 700-K22Z- 1+1L (1) 1+1L 1 700-KL22Z- (1) 1L = Late Break N.C. / Early Make N.O. (2) May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-K40E-ZJM. Coil Voltage Codes The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 230V, 50/60 Hz: Cat. No. 700K40E- becomes Cat. No. 700-K40E-KF. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. For Screw Type Terminal Versions [V] 12 24 110 120 125 220 230 240 250 400 440 480 525 600 AC, 50 Hz -- -- D -- -- -- -- -- -- -- B -- VC -- AC, 60 Hz ------ D -- -- -- -- -- -- -- B -- VC AC, 50/60 Hz -- KJ -- -- -- -- KF KA -- KN -- -- -- -- Standard Standard diode ZQ ZJ ZD -- ZS ZA -- -- ZT -- -- -- -- -- DC -- DJ -- -- -- -- -- -- -- -- -- -- -- -- For Spring Clamp Type Terminal Versions AC, 50 Hz -- -- D -- -- -- -- -- -- -- -- -- -- -- AC, 60 Hz ------ D -- -- -- -- -- -- -- -- -- -- AC, 50/60 Hz -- KJ -- -- -- -- KF -- -- -- -- -- -- -- Standard Standard diode -- ZJ ZD -- -- -- -- -- -- -- -- -- -- -- DC -- DJ -- -- -- -- -- -- -- -- -- -- -- -- Rockwell Automation Publication 700-TD552F-EN-P - January 2021 225 Relay and Timer Specifications Assignment of Contacts Device Combinations in Accordance with IEC 60947-1 / -4-1 Table valid for: AC / DC = 0.85...1.1 x Us, Tamb. = -25 °C...+60 °C, normal position (horizontal rail mounting). Also valid for 700-KR relays and 100-KR auxiliary contacts. (3) Auxiliary Contact Blocks Cat. No. Circuit Diagram Control Front Mounting 100-KFA02E 51 61 52 62 AC/DC 100-KFA11E 53 61 54 62 AC/DC 100-KFA20E 53 63 54 64 AC/DC 100-KFA04E 100-KFA13E 51 61 71 81 52 62 72 82 53 61 71 81 54 62 72 82 AC/DC AC/DC 100-KFA22Z 53 83 61 71 54 84 62 72 AC/DC 100-KFA31Z 53 73 83 61 54 74 84 62 AC/DC 100-KFA40E 53 63 73 83 54 64 74 84 AC/DC (1) Tamb. max. +40 °C (2) Tamb. max. +40 °C and only allowed for coil voltage 24V DC or 230V AC (3) For other operating limits, please contact our technical consultant. Control Relays 700-K (AC and DC Control) 700-K22Z- 700-K31Z- 700-K40E- A1 13 43 21 31 A1 13 33 43 21 A1 13 23 33 43 A2 14 44 22 32 A2 14 34 44 22 A2 14 24 34 44 -- 31Z + 02E = 33Y (1) 40E + 02E = 42Y 22Z + 11E = 33Y 31Z + 11E = 42Y 40E + 11E = 51Y 22Z + 20E = 42Y 31Z + 20E = 51Y 40E + 20E = 60Y -- -- 40E + 04E = 44Y (1) -- 31Z + 13E = 44Y (1) 40E + 13E = 53Y -- 31Z + 22Z = 53Y (1) 40E + 22Z = 62Y -- -- 40E + 31Z = 71Y (2) 22Z + 40E = 62Y 31Z + 40E = 71Y 40E + 40E = 80Y 700-KL22Z- A1 13 47 21 35 A2 14 48 22 36 -- L22Z + 11E = L33Y L22Z + 20E = L42Y -- -- -- -- L22Z + 40E = L62Y 226 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Auxiliary Contact Blocks Photo Description Connection Diagrams For Use With Pkg. Qty. (1) Screw Type Terminals Spring Clamp Terminals N.O. N.C. Cat. No. Cat. No. 51 61 100/104-K, 0 2 700-K 1 100-KFA02E 100-KRFA02E 52 62 Front-mounted auxiliary contacts · Auxiliary Contact Blocks · 2- and 4-pole versions · Choice of contact configurations · Snap on, no tools required · Electronic-compatible bifurcated contacts for signals down to 15V / 2 mA 53 61 1 54 62 53 63 2 54 64 51 61 71 81 0 52 62 72 82 53 61 71 81 1 54 62 72 82 53 83 61 71 2 54 84 62 72 53 73 83 61 3 54 74 84 62 1 100/104-K, 700-K 1 100-KFA11E 100-KRFA11E 0 100/104-K, 700-K 1 100-KFA20E 100-KRFA20E 4 100/104-K, 700-K 1 100-KFA04E 100-KRFA04E 3 100/104-K, 700-K 1 100-KFA13E 100-KRFA13E 2 100/104-K, 700-K 1 100-KFA22Z 100-KRFA22Z 1 100/104-K, 700-K 1 100-KFA31Z 100-KRFA31Z 53 63 73 83 4 54 64 74 84 (1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFA02EM. Control Modules 0 100/104-K, 700-K 1 100-KFA40E 100-KRFA40E Photo Description Mechanical Interlock · For interlocking of two adjacent contactors · No added width to contactor assembly · Front mount plug-in type · Optional auxiliary contact blocks and suppressor modules mount onto the interlock 24...48V AC RC Suppressor 110...280V AC 380...480V AC Surge Suppressor · Plug-in type · Limits surge voltage on coil drop-off MOV Suppressor 12...55V AC, 12...77V DC 56...136V AC, 78...180V DC 137...277V AC, 181...250V DC Diode Suppressor 12...250V DC (1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M. Connection Diagrams For Use With Pkg. Qty. Cat. No. 100/104-K/KR, 700-K/- KR 1 100-KMCH 100/104-K/KR, 700-K/- KR 100/104-K/KR, 700-K/- KR 100/104-K/KR, 700-K/- KR 1 (1) 100-KFSC50 1 (1) 100-KFSC280 1 (1) 100-KFSC480 1 (1) 100-KFSV55 1 (1) 100-KFSV136 1 (1) 100-KFSV277 1 (1) 100-KFSD250 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 227 Relay and Timer Specifications Accessories Photo Description Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm Snap-In Marker Card Pkg. Qty. Cat. No. 10 100-FMS 5 1492-M6X12 228 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 IEC Specifications - 700-K... Relays AC-12 Rated Thermal Current Ambient temperature 40°C Ith 24...240V 230...500V 230...690V Ambient temperature 60°C Ith 24...240V 230...500V 230...690V AC-15/B600 Switching of Solenoids and contactors Ie 24V 48V 120V 230V 240V 400V 480V 500V 600V 690V Short-circuit Protection Fuse gG Min. Switching Capacity 15V Resistance and Power Dissipation Main current circuit resistance, 1 pole Power dissipation, 4 poles Total power dissipation AC control, warm DC control, warm Lifespan Mechanical Electrical AC-15 (240V / 2 A) Weight AC control DC control Load Carrying Capacity per UL/CSA Rated voltage AC Continuous rating 40 °C Switching capacity AC Rated voltage DC Switching capacity DC [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [mA] [m] [W] [W] [W] [Mio. op.] [Mio. op.] kg (lbs.) kg (lbs.) [V] [A] [A] [V] [A] Relay and Timer Specifications 700-K 10 10 10 10 6 6 6 3 3 3 2 2 1.2 1 1 0.6 0.6 10 2 6.5 2.6 4.4 5.2 15 0.7 0.16 (0.35) 0.2 (0.44) max. 600 B 600 max. 600 Q 600 700-KR 6 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 229 Relay and Timer Specifications DC-13/Q600 1 pole 24V [A] 48V [A] 110V [A] 125V [A] 220V [A] 250V [A] 400V [A] 440V [A] 600V [A] Cross Sections Conductor Cross Sections - Main Contacts, Auxiliary Contacts, and Coil Terminals 700-K Terminal type Fine stranded with ferrule (1) Conductor [mm2] (2) Conductors [mm2] Solid or coarse stranded (1) Conductor [mm2] (2) Conductors [mm2] Recommended torque Cross section per UL/CSA Recommended torque (1) Pozidriv No. 2 / Blade No. 3 screw (2) Use same cross sections (3) Stranded wire only [Nm] [AWG] [lb-in] (1) 0.75...2.5 0.75...2.5 1...4 1...2.5 + 1...4 1.2 18...12 (2) 10.6 700-K 2.3 1 0.55 0.55 0.27 0.27 0.15 0.15 0.1 700-KR 0.50...2.5 0.50...2.5 0.75...2.5 (3) 0.75...2.5 (3) -- 18...14 (3) -- 230 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Coil Data Operating Limits AC control 50 Hz, 60 Hz, 50/60 Hz DC control Coil Consumption AC control 50 Hz, 60 Hz, 50/60 Hz DC control Operating Times AC With RC module DC With integrated diode With external diode pick-up dropout pick-up dropout pick-up hold-in pick-up hold-in closing delay opening delay opening delay closing delay opening delay closing delay opening delay [x Us] [x Us] [x Us] [x Us] [VA/W] [VA/W] [W] [W] [ms] [ms] [ms] [ms] [ms] [ms] [ms] Relay and Timer Specifications 700-K 0.85...1.1 0.2...0.75 0.8...1.1 9, 12, 24, 110V DC: 0.7...1.25 0.1...0.75 35/32 5/1.8 cold 3.0, warm 2.6 cold 3.0, warm 2.6 15...40 15...33 15...28 18...40 6...12 8...12 35...50 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 231 Relay and Timer Specifications Dimensions - 700-K... Relays Approximate dimensions are shown in millimeters. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes. (mm) 25° 25° 180° 50 56 54 35 4 35.2 45 49 79 12 *) *) -Minimum distance to grounded parts or walls 232 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Solid-state Relays Product Overview Relay and Timer Specifications Bulletin No. Type Features Load Type Load Voltage Range Load Current Max. (Continuous) Max. Leakage Current to Load Zero Cross Load Switching Equivalent Electromechanical Relay Contact Arrangement Rated Control (Input) Voltage LED Indicator Mounting Method Dielectric Strength Certification Max. Ambient Operating Temperature Page 700-SA 700-SC Tube Base, Socketed Miniature, Ice Cube Socketed Compatible with 700-HN100, 125,108, and 204 socket, LED Compatible with 700-HN103 or 128 socket, LED Status, and Zero- status, zero-cross switching cross AC Switching Options AC (47...63 Hz) DC AC (47...63 Hz) DC 75...264V AC 3...125V DC 75...264V AC 3...52.8V DC or 3...125V DC 5 A 3 A 3 A 3 A @ 48V DC or 2 A @ 110V DC 5 mA @ 100V, 10 mA @ 200V 5 mA @ 125V 5 mA @ 100V AC 10 mA @ 200V AC, 5 mA @ 50V DC or 0.1 mA @ 100V DC Yes Not Applicable Yes (optional) Not Applicable Form A Form A 5...24V DC Yes Panel or DIN with socket 1500V AC, 50/60 Hz, 1 min. cURus, CE, VDE -30...+80 °C (no condensation) 235 5...24V DC, 100...110V AC, 200/220V AC 5...24V DC Yes (optional) Yes (optional for 48V DC) Panel or DIN with socket 1500V AC, 50/60 Hz, 1 min. cURus, CE, VDE -30...+80 °C (no condensation) 240 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 233 Relay and Timer Specifications Product Overview Bulletin No. Type Features (1) 700-SF Square Base, Socketed Compatible with 700-HN116 socket, LED status, zero-cross AC switching Load Type AC (47...63 Hz) DC Load Voltage Range 75...264V AC 3 ... 52.8V DC Load Current Max. 3 A (Continuous) Max. Leakage Current to 5 mA @ 100V AC, 10 mA @ 200V AC 5 mA @ 50V DC Load Zero Cross Load Yes Switching Not Applicable Equivalent Electromecha nical Relay Contact Arrangement Form A Rated Control (Input) 4V DC or 24V DC Voltage LED Indicator Yes Mounting Method Panel or DIN with socket Dielectric Strength 1500V AC, 50/60 Hz, 1 min. Certification cURus, CE, VDE Max. Ambient Operating -30...+80 °C (no condensation) Temperature Page 245 (1) See Solid-state Relay Glossary on page 235 for term definitions. 700-SH Hockey Puck Panel/DIN Mount, High Current, Protective Cover, LED Status AC (47...63 Hz) 3...60V DC 3...50V DC, 24...265V AC 42...530V AC, 42...265V AC, 42...660V AC 10 A/100 A <3 mA 700-SK Slim Line, Socketed Compatible with 700-HN121 socket. Supports Input (sensor) module or Output (SSR) module Output Module Input Module AC (47...63 Hz) DC AC (47...63 Hz) DC 75 ... 264V AC 4 ... 60V DC, 40 ... 200V DC Field Input: 60... Field Input: 264V AC 6.6... 32V DC 2 A 2 A @ 60V, 1.5 A @ 200V Supply Current: 0.1...100 mA Supply Current: 0.1...100 mA 1.5 mA 1 mA 5 A 5 A Yes Yes (optional) N/A No N/A Form A Form A 3...32V DC, 4...32V DC, 80...130V AC, 20...260V AC 20...280V AC/22...48V DC 5... 24 V DC Yes Yes Panel without heat sink, Panel, or DIN with heat sink Panel or DIN with socket >4000V AC RMS 4000V AC, 50/60 Hz, 1 min. cURus, CE, CSA cURus, CE, TÜV -20...+70 °C (no condensation) -30...+80 °C (no condensation) 249 258 234 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Solid-state Relay Glossary Terms Insulation Circuit functions Input Output Meaning Basic insulation Insulation for basic protection from electric shock (IEC950 1.2.9.2) Supplemental insulation Independent insulation that is provided outside of basic insulation to protect from electric shock when the basic insulation breaks down (IEC950 1.2.9.3) Reinforced insulation A single-layer of insulation (IEC950 1.2.9.5) that provides the same protection from electric shock as double insulation (insulation including both basic and supplemental insulation) according to conditions stipulated in IEC950 standards Zero cross circuit A circuit that starts operation with the AC load voltage at close to zero-phase. Trigger circuit A circuit for controlling the triac or thyristor trigger signal, which turns the load current ON and OFF. Isolated input circuit If the external circuit is prone to generating noise, or if wires from external sources are prone to the influence of inductive noise, in order to prevent malfunctions due to noise, it is necessary to electrically isolate internal circuits and external circuits (output circuits). An isolated input circuit is a circuit that isolates inputs and outputs by using components that are not connected electrically but that can transmit signals, such as contact relays or photocouplers. Photocoupler A component that runs the electric signal into a light emitter (for example, LED), changes it to a light signal, and then returns it to an electric signal using a photoelectric conversion element, such as a photo transistor. The space that is used for transferring the light signal is isolated thus providing good insulation and a high propagation speed. Rated voltage The voltage that serves as the standard value of an input signal voltage Pickup (must-operate) voltage Minimum input voltage when the output status changes from OFF to ON. Input impedance The impedance of the input circuit and the resistance of current-limiting resistors used. Impedance varies with the input signal voltage in case of the constant current input method. Operating voltage The permissible voltage range within which the voltage of an input signal voltage may fluctuate. Dropout (Reset) voltage Maximum input voltage when the output status changes from ON to OFF. Input current The current value when the rated voltage is applied. Load voltage This is the effective value for the power supply voltage that can be used for load switching or in the continuous-OFF state. Maximum load current (continuous) The effective value of the maximum current that can continuously flow into the output terminals under specified cooling conditions (i.e., the size, materials, thickness of the heat sink, and an ambient temperature radiating condition). Leakage current The effective value of the current that can flow into the output terminals when a specified load voltage is applied to the SSR with the output turned OFF. Output ON voltage drop The effective value of the AC voltage that appears across the output terminals when the maximum load current flows through the SSR under specified cooling conditions (such as the size, material, and thickness of heat sink, ambient temperature radiation conditions, etc.). Minimum load current (continuous) The minimum load current at which the SSR can operate normally. Snubber circuit A circuit consisting of a resistor R and capacitor C, which prevents faulty ignition from occurring in the SSR triac by suppressing a sudden rise in the voltage that is applied to the triac. Semiconductor output This is a generic name for semiconductors such as the thyristor, triac, power transistor, and power MOS FET. In element (switching element) particular, triacs are often used in SSRs because they allow switching to be performed with one element. Repetitive peak OFF-state voltage (VDRM) This is a rating for an output semiconductor that used in an SSR for AC loads. Collector-emitter voltage (VCEO) This is a rating for an output semiconductor that used in an SSR for DC loads. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 235 Relay and Timer Specifications Terms Characteristics Others Meaning Operating (pick-up) time A time lag between the moment a specified signal voltage is imposed to the input terminals and the output is turned ON. Release (drop-out) time A time lag between the moment the imposed signal input is turned OFF and the output is turned OFF. Insulation resistance The resistance between the input and output terminals or I/O terminals and metal housing (heat sink) when DC voltage is imposed. Dielectric strength The effective AC voltage that the SSR can withstand when it is applied between the input terminals and output terminals or I/O terminals and metal housing (heat sink) for more than 1 minute. Ambient temperature and humidity (operating) The ranges of temperature and humidity in which the SSR can operate normally under specified cooling, input/output voltage, and current conditions. Storage temperature The temperature range in which the SSR can be stored without voltage imposition. Inrush current resistance A current, which can be applied for short periods of time to the electrical element. Counter-electromotive force Extremely steep voltage rise which occurs when the load switched or turned OFF. Recommended applicable load The recommended load capacity which takes into account the safety factors of ambient temperature and inrush current. Bleeder resistance The resistance connected in parallel to the load in order to increase apparently small load currents, so that the ON/OFF of minute currents functions normally. (It is also used to shunt leakage currents.) Solid-state Relay Switching Capacity Solid-State Equivalent EM Relay Type Relay Contact Configuration 700-SA Form A 700-SC Form A 700-SF 700-SH * Form A Form A 700-S KO Form A Load Voltage Zero-Cross Load Maximum AC an d DC Switching Capability Switching 1 mA 10 mA 50 mA 100 mA 1 A 3 A 5 A 10 A 2 0 A 25 A De vice 30 A 35 A AC Yes Triac DC N/A Transistor AC Yes Triac DC N/A Transistor (2 A) AC Yes Triac DC N/A Transistor AC Yes Thyristor or Triac DC N/A Transistor AC Yes Triac (2 A) DC N/A Transistor 100 A IMPORTANT * Requires a heat sink to reach maximum current value. 236 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-SA Tube Base Relays · 5 A (resistive) max. continuous load (output) current · 264V AC or 125V DC max. load voltage options · Photocoupler isolation between control and load voltage · LED indicator (standard) for input/logic ON/OFF status monitoring · 700-HN100, -HN125, -HN 202, or -HN108 specialty socket compatible · 700-HT2 timing module Input-to-Output Isolation Method Zero Cross Function Status Indicator Photocoupler Yes Yes Not Applicable Output (Load) Max. Continuous Current and Rated Voltage Range 5 A @ 100...240V AC (47...63 Hz) 3 A @ 5...110V DC Rated Input (Control) Voltage 5...24V DC Cat. No. 700-SAZY5Z25 700-SANY3Z25 Accessories - 700-SA Relays Photo Description Pkg. Quantity 10 Cat. No. 700-HN100 Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction. 8 Pin for use with DPDT 700-HA Relays. 10 Specialty Socket 8 Pin back wired socket with solder terminals 10 Screw Terminal Tube Base Socket -- Panel or DIN Rail Mounting; Open Style Construction. 8 Pin for use with DPDT 700-HA Relays. No retainer clip required. 10 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 10 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized 10 printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 Retainer Clip for Sockets with 700-SA AND 700-HB Relays. Secures relay in socket. 10 8-Pin Socket -- Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal Tube Base Sockets -- panel or DIN Rail mounting. Guarded terminal construction. Used with DPDT 700-HA Relays. 700-HN108 700-HN125 199-DR1 700-N40 700-N41 700-HN158 700-HN204 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 237 Relay and Timer Specifications Specifications - 700-SA Relays Control/Input Ratings Cat. No. 700-SAZY5Z25 700-SANY3Z25 Rated Control Voltage 5...24V DC Max. Operating Control Voltage Range 4...32V DC 4...30V DC Max. Reverse Control Voltage -32V DC -30V DC Impedance 15 mA max. (1) 1.5 k (+20% -10%) Control Voltage Levels Pick-up Voltage Drop-out Voltage 4V DC max. 1V DC min. Load/Output Ratings Cat. No. 700-SAZY5Z25 700-SANY3Z25 Rated Load Voltage 100...240V AC 5...110V DC Maximum Load Voltage Range 75...264V AC 3...125V DC Continuous Load Current (Resistive) [A] Min. Max. (2) 0.1 5.0 0.1 3.0 Max. Inrush Current (3) 80 A, @ 50/60 Hz for 1 cycle 12 A (10 ms) Characteristics Description Cat. No. 700-SAZY5Z25 Cat. No. 700-SANY3Z25 Load Switching Method/Device Pick-up Time Drop-out Time Triac 1/2 cycle of load power source cycle time (4) + 1 ms max. 1/2 cycle of load power source cycle time (4) + 1 ms max. Transistor 0.5 ms max. 2.5 ms max. Output ON Voltage Drop 1.6V (RMS) max. 1.5V max. Output Leakage Current 5 mA max. (at 100V AC); 10 mA max. (at 200V AC) 5 mA max. (at 125V DC) Output VDRM VCEO (V) Output di/dt (V/uS) 600 150 50 -- Output dv/dt (V/uS) Output I2t (A2S) 500 -- 41.6 -- Output Tj (ºC) Max. 125 150 Insulation Resistance 100 M min. (at 500V DC) Dielectric Strength 1500V AC, 50/60 Hz for 1 min Vibration Resistance (Max.) Shock Resistance (max.) 10...55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G) Ambient Temperature Operating Storage 30...+80 °C (22...+176 °F) with no icing or condensation 30...+100 °C (22...+212 °F) with no icing or condensation Ambient Humidity 45...85% (no condensation) Standards Compliance UL 508, CSA C22.2 No. 14, EN 60947-1, -4-3 Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Weight Approx. 70 g (1) With constant current input system. SSR input impedance varies with a change in input (control) voltage. (2) See the following graph"Load Current Vs. Ambient Temperature Characteristics"for additional load current details. (3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See"Inrush Current Resistivity"graph. (4) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms. Load Current [A] -30 -20 0 20 40 60 80 100 Inrush Current [A. Peak] 10 30 50 100 200 500 1000 5000 Load Current vs. Ambient Temperature Characteristics 700-SA 700-SAZY5Z25 5 4 700-SANY3Z25 3 2 1 0 Inrush Current Resistivity (1) 700-SA 80 70 60 50 40 700-SAZY5Z25 30 20 10 700-SANY3Z25 0 Ambient Temperature [° C] Energizing Time [ms] (1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. 238 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Terminal Arrangement (Bottom View) Relay and Timer Specifications Load Load power supply Load Input Input voltage Note: The plus and minus symbols shown in parentheses are for DC loads. Basic Application Considerations High Density Mounting of Multiple Solid-state Relays (SSRs) If multiple SSRs are installed side by side,, the outer case wall of the SSR serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current to half. Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage that is outlined in the table. Load Voltage 100...120V AC 200...240V AC 380...480V AC Varistor Voltage [V] 240...270 440...470 820...1000 Varistor Surge Resistance 1000 A min. TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001. For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load. Input SSR Load Load power supply EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions: 3 m max. Load Input 700-SA Output Varistor: 470 V, 0.6 W Film Capacitor: 1µ F, 250 VAC Varistor Film Capacitor · Connect a varistor between the output terminals. · Connect a film capacitor to the load power supply. · The input cable must be less than 3 m. 2. DC-switching models comply with EMC Directives under the following conditions: Less than 10 m Load Input 700-SA Output · The input cable must be less than 10 m. Dimensions - 700-SA Relays All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes. 700-SA (1) + 35 max. + 35 52.5 max. max. (1) 700-SA is compatible with Cat. Nos. 700-HN100, -108, -125, and -204 (sockets). Rockwell Automation Publication 700-TD552F-EN-P - January 2021 239 Relay and Timer Specifications 700-SC Ice Cube Relays · 3 A (resistive) max. continuous load (output) current · 264V AC, 48V DC or 125V DC max. load voltage options · 5...24V DC or 110/220V AC control (input) voltage options · LED indicator (optional) for input/logic On/Off status monitoring · 700-HN103, 700-HN104, or 700-HN128 socket compatible · Compatible with 700-AT1 or 700-AT2 timer modules Input-to-Output Isolation Method Zero Cross Function Status Indicator Photocoupler Phototriac Photocoupler Phototriac Photocoupler Yes Yes No Not Applicable Yes No No Not Applicable Output (Load) Max. Continuous Current and Rated Voltage Range 3 A @ 100...240V AC(1) 2 A @ 100...240V AC(1) 3 A @ 100...240V AC (1) 3 A @ 4...48V DC 3 A @ 100...240V AC (1) 3 A @ 4...48V DC 2 A @ 5...110V DC Rated Input (Control) Voltage 5...24V DC 100/110V AC 200/220V AC 24V DC 5...24V DC 4...24V DC 24V DC 4...24V DC 5...24V DC Cat. No. 700-SCZY3Z25 700-SCZY2A1 700-SCZY2A2 700-SCTY3Z24 700-SCNY3Z25 700-SCZN3Z26 700-SCTN3Z24 700-SCNN3Z26 700-SCNN2Z25 (1) 47...63 Hz . Accessories - 700-SC Relays Photo Description Pkg. Quantity Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction.Ith = 10 A per pole. 14-blade miniature socket for use with 700-SC Relays. 10 700-HN103 Screw Terminal Socket -- Panel or DIN Rail Mounting; Guarded Terminal Construction Ith = 10 A per pole. 14-blade miniature socket for use with 700-SC relays. This socket has coil and contact separation and the ability to plug in optional plug-in modules (700-A__ accessories: LED, 10 Surge Suppression, Timing Modules) 700-HN104 Screw Terminal Base Socket -- Panel or DIN Rail Mounting; Open-Style Construction Ith = 10 A per pole. 14-blade miniature socket for use with 700-SC Relays. 10 700-HN128 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 199-DR1 240 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Photo Description Pkg. Quantity Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. 10 Tags are peel-off with sticky backing for easy placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10 easy placement on relays. Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC Relays. Secures relay in socket. 10 Cat. No. 700-N40 700-N41 (1) 700-HN114 (1) Series B retainer clip must be used with 700-SC. Specifications- 700-SC Relays Control/Input Ratings Cat. No. 700-SCZY3Z25 Rated Control Voltage 5...24V DC Max. Operating Control Voltage Range 4...28V DC Max. Reverse Control Voltage [V] -28.8 Impedance 15 mA max. (1) Control Voltage Levels Pick-up Voltage Drop-out Voltage 4V DC max. 1V DC min. 700-SCZY2A1 100/110V AC 75...125V AC NA 41 k ±20% 75V AC max. 20V AC min. 700-SCZY2A2 700-SCTY3Z24 700-SCNY3Z25 200/220V AC 24V DC 5...24V DC 150...250V AC 19.2...28.8V DC 4...28V DC NA 72 k ±20% 150V AC max. 40V AC min. -28.8 2 k ±20% 19.2V DC max. -28 1.5 k +20%/ -10% (2) 4V DC max. 700-SCZN3Z26 4...24V DC 3...28V DC -28.8 700-SCTN3Z24 24V DC 19.2...28.8V DC -28.8 15mAmax. (1) 2 k ±20% 3V DC max. 19.2V DC max. 1V DC min. 700-SCNN3Z26 700-SCNN2Z25 4...24V DC 5...24V DC 3...28V DC -28 1.5 k +20%/ -10% (2) 3V DC max. -28.8 Load/Output Ratings Cat. No. Rated Control Voltage Max. Load Voltage Range Continuous Load Current (Resistive) [A] Min. Max. (3) Max. Inrush Current (4) 700-SCZY3Z25 700-SCTY3Z24 700-SCZN3Z26 700-SCTN3Z24 100...240V AC 75...264V AC 0.1 3 45 A (@50/60 Hz, 1 cycle) 700-SCZY2A1 700-SCZY2A2 0.1 2 700-SCNN3Z26 700-SCNY3Z25 4...48V DC 3...52.8V DC 0.1 3 18 A (10 ms) 700-SCNN2Z25 5...110V DC 3...125V DC 0.1 2 10 A (10 ms) (1) With constant current input circuit system. SSR impedance varies with a change in input (control) voltage. (2) Input impedance attains its maximum at the operating voltage. (3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See"Inrush Current Resistivity"graphs on page 112 for details (4) See Load Current Versus Ambient Temperature Characteristics on page 242 for additional load current details. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 241 Relay and Timer Specifications Characteristics Description Cat. No. 700-SCZ... Cat. No. 700-SCT Cat. Nos. 700-SCNY, 700SCNN3... Cat. Nos. 700-SCNN2... Load Switching Method/Device Triac Transistor Pick-up time 1/2 of load power source cycle time (1) + 1 ms max. (DC input) 3/2 of load power source cycle time (1) + 1 ms max. (AC input) Drop-out time 1/2 of load power source cycle time (1) + 1 ms max. (DC input) 3/2 of load power source cycle time (1) + 1 ms max. (AC input) 1/2 of load power source cycle time (1) + 1 ms max. 2 ms max. 2.5 ms max. Output On Voltage Drop 1.6V (RMS) max. 1.6V (RMS) 1.5V max. 1.5V max. Output Leakage Current 5 mA max (@ 100V AC) 10 mA max (@ 200V AC) 2.5 mA max (@ 100V AC) 5 mA max (at 200V AC) 5 mA max (@ 50V DC) 0.1 mA max (@ 100V DC) Output VDRM, VCEO (V) 600 600 80 80 Output di/dt (A/uS) 50 50 -- -- Output dv/dt (V/uS) 250 250 -- -- Output I2t (A2S) 18 18 -- -- Output Tj (°C) Max. 125 125 150 150 Insulation Resistance 100 M min (@500V DC) Dielectric Strength 1500V AC, 50/60 Hz for 1 minute Vibration Resistance (max.) Shock Resistance (max.) 10...55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G) Ambient Temperature Operating: -30...+80 °C (-22...+176 °F) with no icing or condensation Storage: -30...+100 °C (-22...+212 °F) with no icing or condensation Standards Compliance UL 508, CSA C22.2 No. 14, EN/IEC 60950, EN 50011, EN 61000-6-2, EN/IEC 60947-1, -4-3 Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Ambient Humidity Operating: 45...85% (no condensation) Weight Approx. 50 g (1) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms Load Current Versus Ambient Temperature Characteristics 700-SC_ _3... 700-SC_ _2... 5 5 4 4 Load Current [A] -30 -20 0 20 40 60 80 100 Load Current [A] -30 -20 0 20 40 60 80 100 3 3 2 2 1 0 Ambient Temperature [° C] 1 0 Ambient Temperature [° C] 242 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Inrush Current [A. Peak] 10 30 50 100 200 500 1000 5000 Inrush Current [A. Peak] 10 20 30 50 70 100 200 300 500 1000 2000 Inrush Current [A. Peak] 10 20 30 50 100 300 500 1000 3000 5000 Inrush Current Resistivity (1) 700-SCZ.... 700-SCT... 50 40 30 20 10 0 700-SCNN3... 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 700-SCNY3 700-SCNN2... 12 10 8 6 4 2 0 Energizing Time [ms] Energizing Time [ms] Energizing Time [ms] (1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2...5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions 3 m max. Load Input 700-SC Output Varistor: 470 V, 0.6 W Film capacitor: 1µ F, 250 VAC Varistor Film capacitor · Connect a varistor between the output terminals. · Connect a film capacitor to the load power supply. · The input cable must be less than 3 m. 2. DC-switching models comply with EMC Directives under the following conditions Less than 10 m Load Input 700-SC Output · The input cable must be less than 10 m. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 243 Relay and Timer Specifications Dimensions - 700-SC Relays All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes. 28 max. 21.5 max. (1) 700-SC is compatible with Cat. Nos. 700-HN103, -HN104, and -HN128 socket. Basic Application Considerations for 700-SC 36.5 max. 42.5 max. Terminal Arrangement/ Internal Connections (Bottom View) 1 4 5 8(+) 9 Load 12() Load 13 Input 14 + Input voltage + (+) Load power supply () Cat. No 700-SC... (1) Note: The plus and minus symbols shown in parentheses are for DC loads. High-density Mounting of Multiple Solid-state Relays (SSRs) If multiple relays are mounted side by side, the outer wall of each SSR works as a radiator. The SSR casing serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Connection For DC Load Switching, 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal. Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage that is outlined in the table below. Load Voltage [V AC] 100...120 200...240 380...480 Varistor Voltage [V] 240...270 440...470 820...1000 Varistor Surge Resistance 1000 A min. TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001. Input SSR Load Load power supply 244 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-SF Square Base Relays · 3 A (resistive) max. continuous load (output) current · 264V AC or 52.8V DC max. load voltage options · 4...24V DC control/input voltage · Photocoupler or phototriac isolation option between control and output voltage · LED Indicator for input/logic ON/OFF status monitoring · 700-HN116 socket compatible Input-to-Output Isolation Method Zero Cross Function Status Indicator Photocoupler Phototriac Photocoupler Yes No Yes Not Applicable Output (Load) Max. Continuous Current and Rated Voltage Range 3 A @ 100...240V AC (47...63 Hz) 3 A @ 4...48V DC Rated Input Control Voltage Cat. No. 5...24V DC 24V DC 4...24V DC 700-SFZY3Z25 700-SFTY3Z24 700-SFNY3Z25 Accessories-700-SF Relays Photo Description Pkg. Quantity Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF relays. 10 700-HN116 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10 easy placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC Relays. Secures relay in socket. 10 (1) 700-SF must use Cat. No. 700-HN114 series B retainer clip. 199-DR1 700-N40 700-N41 700-HN114(1) Specifications- 700-FS Relays Control/Input Ratings Cat. No. Rated Control Voltage 700-SFZY3Z25 700-SFTY3Z24 700-SFNY3Z25 5...24V DC 24V DC 5...24V DC Max. Operating Control Voltage Range [V DC] 4...28V DC 19.2...28.8V DC 4...28V DC Max. Reverse Control Voltage [V] Impedance 32 15 mA max. (1) 28.8 2 k ± 20% 28.8 1.5 k + 20%/ 10% (2) Control Voltage Levels Pick-up Voltage Drop-out Voltage 4V DC max. 19.2V DC max. 1V DC min. 1V DC min. 4V DC max. 1V DC min. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 245 Relay and Timer Specifications Load/Output Ratings Cat. No. Rated Control Voltage 700-SFZY3Z25 700-SFTY3Z24 700-SFNY3Z25 100...240V AC 4...48V DC Max. Load Voltage Range 75...264V AC 3...52.8V DC Continuous Load Current (Resistive) [A] Min. Max. (3) 0.1 3 0.1 3 0.1 3 Max. Inrush Current (4) 45 A @ 50/60 Hz, 1 cycle 18 A (10 ms) Characteristics Description Load Switching Method/Device Pick-up Time Drop-out Time Output ON Voltage Drop Output Leakage Current Output VDRM, VCEO (V) Output di/dt (A/uS) Output dv/dt (V/uS) Output I2t (A2S) Output Tj (°C) Max. Insulation Resistance Dielectric Strength Vibration Resistance (Max.) Shock Resistance (Max.) Ambient Temperature Ambient Humidity Standards Compliance Certifications Weight Cat. No. 700-SFZY3Z25 Cat. No. 700-SFTY3Z24 Triac Transistor 1/2 cycle of load power source cycle time (5) +1msmax. 1 ms max. 1/2 cycle of load power source cycle time (5) + 1 ms max. Cat. No. 700-SFNY3Z25 0.5 ms max. 2 ms max. 1.6V (RMS) max. 5 mA max. (@ 100V AC); 10 mA max. (@ 200V AC) 600 2.5 mA max. (@ 100V AC); 5 mA max. (@ 200V AC) 600 1.5V max. 5 mA max. (@ 50V DC) 80 50 50 -- 250 250 -- 18 18 -- 125 125 150 100 M min.(at500VDC) 1,500V AC, 50/60 Hz for 1 min 10...55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G) Operating: 30...+80 °C (22...+176 °F) with no icing or condensation Storage: 30...+100 °C (22...=+212 °F) with no icing or condensation 45...85% (no condensation) UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-3, EN/IEC 60950 cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified Approx. 50 g (1) With constant current input circuit system, SSR impedance varies with a change in input voltage. (2) Input impedance reaches its maximum at the operating voltage. (3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See the "Inrush Current Resistivity"graphs on page 116 for more details. (4) See"Load Current vs. Ambient Temperature Characteristics"on page 116 for additional load current details. (5) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time 20 ms. IMPORTANT This data is non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2...5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. 246 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Load Current [A] -30 -20 0 20 40 60 80 100 Inrush Current [A Peak] 10 30 50 100 200 500 1000 5000 Inrush Current [A] 10 20 30 50 70 100 200 300 500 1000 2000 Load Current vs. Ambient Temperature Characteristics 700-SF Inrush Current Resistivity (1) 700-SFZ... 700SFT... Inrush Current Resistivity (1) 700-SFN... 4 50 30 28 26 3 40 24 22 20 30 18 16 2 14 20 12 10 1 8 10 6 4 2 0 0 0 Ambient Temperature [° C] Energizing Time [ms] Energizing Time [ms] (1) Inrush current resistivity is defined as the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2...5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. EMC Directive Compliance 1. AC-switching models comply with EMC Directives under the following conditions 3 m max. Load Input 700-SF Output Varistor: 470 V, 0.6 W Film capacitor: 1µ F, 250 VAC Varistor Film capacitor · Connect a varistor between the output terminals. · Connect a film capacitor to the load power supply. · The input cable must be less than 3 m. 2. DC-switching models comply with EMC Directives under the following conditions Less than 10 m Load Input 700-SF Output · The input cable must be less than 10 m. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 247 Relay and Timer Specifications Dimensions - 700-SF Relays All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for manufacturing purposes. 28 max 21.5 max 36.5 max 42.5 max Terminal Arrangement/Input Connections (Bottom View) 1 2 3 4(+) (+) Load 5 Load 6(-) (-) 7 Input 8 - + - Input Voltage + Notes: 1. The plus and minus symbols shown in parentheses are for DC loads. 2. The coil has no polarity. IMPORTANT 700-SF is compatible with Cat. No. 700-HN116 socket. Basic Application Considerations of 700-SF High-density Mounting of Multiple Solid-state Relays (SSRs) If multiple SSRs are mounted side by side, the outer case wall of the SSR acts as a radiator. The SSR case serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Connection For DC load switching, the Bul. 700-SF SSR will operate properly if the load is connected to either the positive or negative load terminals. Protective Component to Extend SSR Life When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in surge suppression (700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device. Select a varistor that meets the conditions of the load voltage that is outlined in the table. Load Voltage [V AC] 100...120 200...240 380...480 Varistor Voltage [V] 240...270 440...470 820...1000 Varistor Surge Resistance 1000 A min. TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001. For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load. Input SSR Load Load power supply 248 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications 700-SH Hockey Puck Relays · 100 A max. continuous load (output) current with appropriate heat sink · 264V AC, 530V AC, or 660V AC max. load voltage options · 3...32V DC, 4...32V DC, 80...130V AC, 200...260V AC, 20...280V AC/22...48V DC control (input) voltage options · LED indicator for input/logic ON/OFF status monitoring · Protective cover for added safety Photo Input-toOutput Isolation Method Optocoupler Zero Cross Function Status Indicator Yes Yes Yes No Yes Yes Output (Load) Max. Continuous Current and Rated Voltage Range (1) 10 A @ 42...265V AC 10 A @ 42...265V AC 10 A @ 42...265V AC 10 A @ 42...530V AC 25 A @ 42...530V AC 25 A @ 24...265V AC 25 A @ 24...265V AC 50 A @ 24...265V AC 50 A @ 24...265V AC 50 A @ 42...530V AC 25 A @ 42...660V AC 25 A @ 42...660V AC 50 A @ 42...660V AC 50 A @ 42...660V AC 75 A @ 42...530V AC 75 A @ 42...660V AC 75 A @ 42...530V AC 75 A @ 42...660V AC 100 A @ 42...530V AC 100 A @ 42...530V AC 100 A @ 42...660V AC 100 A @ 42...660V AC 5 A @ 3...60V DC 25 A @ 90...280V AC 50 A @ 90...280V AC Rated Input Control Voltage Cat. No.(2) 3...32V DC 80...130V AC 200...260V AC 4...32V DC 4...32V DC 3...32V DC 20...280V AC/ 22...48V DC 3...32V DC 20...280V AC/ 22...48V DC 4...32V DC 4...32V DC 20...280V AC/ 22...48V DC 4...32V DC 20...280V AC/ 22...48V DC 4...32V DC 4...32V DC 20...280V AC/ 22...48V DC 20...280V AC/ 22...48V DC 4...32V DC 20...280V AC/ 22...48V DC 4...32V DC 20...280V AC/ 22...48V DC 3...32V DC 4...20 mA DC 4...20 mA DC 700-SH10JZ24 700-SH10JA12 700-SH10JA22 700-SH10HZ25 (Series B) 700-SH25HZ25 (Series B) 700-SH25GZ24 700-SH25GA24 700-SH50GZ24 700-SH50GA24 700-SH50HZ25 700-SH25VZ25 700-SH25VA24 700-SH50VZ25 700-SH50VA24 700-SH75HZ25 700-SH75VZ25 700-SH75HA24 700-SH75VA24 700-SH100HZ25 700-SH100HA24 700-SH100VZ25 700-SH100VA24 700-SH5FZ24 700-SH25WA25 700-SH50WA25 (1) When used with heat sink. (2) All catalog numbers are Series A unless noted. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 249 Relay and Timer Specifications Accessories - 700-SH Relays Photo Description Heat Sink-- Panel or DIN Rail Mount Pkg. Quantity 1 Cat. No. 700-SN10 Heat Sink-- Panel or DIN Rail Mount 1 700-SN25 Heat Sink-- Panel or DIN Rail Mount 1 700-SN50 Heat Sink-- Panel or DIN Rail Mount 1 700-SN50HC Heat Sink-- Panel or DIN Rail Mount 1 700-SN50VHC DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m Thermal Conductive Pads Plastic Covers -- for DC output version Thermal Adapters - for 100 A Wire 10 199-DR1 50 700-SHCPAD 25 700-SHCOV 10 700-SHTRMA 250 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications- 700-SH Relays Control/Input Ratings Cat. No. Operating Voltage 700-SH10J... 700-SH_ _ H... 700-SH_ _ G... 700-SH_ _ V... 700-SH_ _ W... 700-SH_ _ F... (1) When specified heatsink is used. Output Ratings 3...32V DC 80...130V AC 200...280V AC 4...32V DC 20...280V AC/22...48V DC 3...32V DC 20...280V AC/22...48V DC 4...32V DC 20...280V AC/22...48V DC Current Control 3...32V DC 700-SH5FZ24 700-SH10J... 700-SH10H... 700-SH25G... 700-SH25H... 700-SH25V... 700-SH25W... 700-SH50G... 700-SH50H... 700-SH50V... 700-SH50W... 700-SH75H... 700-SH75V... 700-SH100H... 700-SH100V... (2) AC unless indicated. Cat. No. Input Current @ Max. Voltage 12 mA 13 mA 13 mA 12 mA 20 mA 12 mA 20 mA 12 mA 20 mA 4...20 mA 12 mA Voltage Level Pickup Voltage 2.75V DC max. 70V AC max. 190V AC max. 4V DC max. 18V AC/DC 2.5V DC -32V DC 3.5V DC 18V AC/DC -- 3V DC max. Drop-out Voltage 1.2V DC min. 30V AC min. (1) 90V AC min. 1V DC min. 6V AC/DC 1.2V DC 6V AC/DC 1.2V DC 6V AC/DC -- 1.0V DC Load Voltage Range 3...60V DC 42...265V AC 42...530V AC 24...265V AC 42...530V AC 42...660V AC 90...280V AC 24...265V AC 42...530V AC 42...660V AC 90...280V AC 42...530V AC 42...660V AC 42...530V AC 42...660V AC Applicable Load Current with Heat Sink [A] (2) 0.001...5 A DC 0.15...10 0.15...10 0.15...25 0.15...25 0.15...25 0.15...25 0.15...50 0.15...50 0.15...50 0.15...50 0.15...75 0.15...75 0.15...100 0.15...100 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 251 Relay and Timer Specifications Characteristics Description Pick-up Time Drop-out Time Output ON Voltage Drop Output Leakage Current Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance Ambient Temperature Ambient Humidity Standards Compliance Certifications Weight Cat. Nos. 700-SH10, 25, 50 (not including 700-SH_ _W) Cat. Nos. 700-SH75, 100 1/2 of load power source cycle time(DC input) / 1 of load power source cycle time (AC input) 1/2 of load power source cycle time (DC input) / 2 of load power source cycle time (AC input) 1.6V (RMS) max. <3 mARMS 100M min(@500VDC) 100M min.(at500VDC) >4000V ACRMS Malfunction: 10...55 Hz, 1.5 mm double amplitude Malfunction: 1000 m/s2 Operating: 20...+70 °C (4...+158 °F) with no icing or condensation Storage: 40...+100 °C (40...+212 °F) with no icing or condensation 0...95% no condensing UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4 cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924) Approx. 60 g Approx. 100 g Pick-up Current Drop-out Current Voltage Drop Leakage Current Insulation Voltage Vibration Resistance Shock Resistance Ambient Temperature Ambient Humidity Standards Compliance Certifications Weight Description Cat. No. 700-SH_ _W 4.2 mA 4.1 mA <10V DC @ 20 mA <3 mA <4000 VRMS Malfunction: 10...55 Hz, 1.5 mm double amplitude Malfunction: 1000 m/s2 Operating: 20...+70 °C (4...+158 °F) with no icing or condensation 0...95% no condensing UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4 cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 24024) Approx. 60 g Description Pick-up Voltage Drop-out Voltage Activating Frequency Input Impedance Response Time Pick-up @ Vin > 5V Response Time Drop-out On-state Voltage Drop @ Rated Current Cat. No. 700-SH5FZ24 <3V DC >1V DC <100 Hz 1 k <4000 uS <1 mS <1.5V 252 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Description Off-state Current Drop @ Rated Voltage Insulation Voltage Vibration Resistance Shock Resistance Ambient Temperature Ambient Humidity Standards Compliance Certifications Weight Surge Current vs. Ambient Temperature Characteristics Cat. No. 700-SH5FZ24 <1 mA <1 mA Malfunction: 10...55 Hz, 1.5 mm double amplitude Malfunction: 1,000 m/s2 Operating: 20...+70 °C with no icing or condensation 0...95% no condensing UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN61000-6-4 cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924) Approx. 60 g Inrush current (Apk) 350A 300A 250A 200A 150A 100A 50A 0A 10ms 1200A 1000A 800A 600A 400A 200A 0A 10ms Surge current resistivity for 700-SH10, 25.... 100ms Energizing time (ms) 1000ms Surge current resistivity for 700-SH75.... 100ms Energizing time (ms) 1000ms 10000m s 10000m s Inrush current (Apk) Inrush current (Apk) 700A 600A 500A 400A 300A 200A 100A 0A 10ms 2000A 1800A 1600A 1400A 1200A 1000A 800A 600A 400A 200A 0A 10ms Surge current resistivity for 700-SH50.... 100ms Energizing time (ms) 1000ms Surge current resistivity for 700SH100.... 100ms Energizing time (ms) 1000ms 10000m s 10000m s Inrush current (Apk) Rockwell Automation Publication 700-TD552F-EN-P - January 2021 253 Relay and Timer Specifications Load Current (A) Load Current (A) Load current vs. ambient temperature characteristics for 700-SH10.... 12 700-SN50VHC 10 700-SN50HC 700-SN10 700-SN25 8 700-SN50 6 4 No heatsink 2 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient temperature (ºC) Load current vs. ambient temperature characteristics for 700-SH50.... 6 0 5 0 4 0 7 0 0 - S N 1 0 3 0 7 0 0 - S N 2 5 7 0 0 - S N 5 0 7 0 0 - S N 5 0 V H C 7 0 0 - S N 5 0 H C 2 0 1 0 0 - 2 0 No heatsink - 1 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 Ambient temperature (ºC) Load current vs. ambient temperature characteristics for 700-SH100.... 120 100 700-SN50 700-SN50HC 700-SN50VHC 80 60 700-SN10 40 700-SN25 20 No heatsink 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient temperature (ºC) Load Current (A) Load Current (A) Load Current (A) Load Current (A) Load current vs. ambient temperature characteristics for 700-SH25.... 30 25 700-SN50(V)HC 700-SN10 700-SN25 700-SN50 20 15 10 5 No heatsink 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient temperature (ºC) 80 70 60 50 40 30 20 10 0 -20 Load current vs. ambient temperature characteristics for 700-SH75.... 700-SN50VHC 700-SN50HC 700SN10 700-SN25 700-SN50 No heatsink -10 0 10 20 30 40 50 60 70 80 Ambient temperature (ºC) Load current vs. ambient temperature characteristics for 700-SH5..... 6 700-SN50(V) HC 5 700-SN10 700-SN25 700-SN50 4 No heatsink 3 2 1 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient temperature (ºC) 254 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Mounting Considerations (1) (2) (3) (4) All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not intended for manufacturing purposes. 45.5 58.2 30.0 47.5 24.5 5.3 2 x M5 Screws 2 x M3 Screws Mounting Holes (Bottom View) Terminal Arrangement/ Internal Connections (Top View) Load Load Power Load Supply 47.5 Two Ø 4.4 or M4 Holes L1 T1 A2 A1 Input 13.0 25 45.5 Cat. No. 700-SH5F... 44.8 28.8 47.5 58.2 12.3 2 X M5 Screws 8.6 Operating Indicator 2 X M3 Screws APPLY HEATSINK COMPOUND 5.2 5.25 25 45.5 Cat. No. 700-SH10, -SH25, -SH50, -SH75, -SH100 Two Ø 4.4 or M4 Holes 47.5 (1) The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow. If the fins do not run perpendicular to the floor, a 30% current derating is required. (2) When attaching a heat sink to 700-SH, apply a thin layer of heat conductive grease (approximately 0.002 in. thick) on the heat sink to maximize heat transfer between the SSR and the heat sink. Recommended types: Silicon based, Dow Corning 340, Toshiba YG6240; Non-silicon based, AOS company type 53300 (Cat. No. 46801-010-01). (3) Tighten the SSR panel/heat sink mounting screws to a torque of 0.78...0.98 N·m (6.9...8.7 lb·in). (4) Tighten the SSR terminal wiring screws as follows M4: 0.98...1.37 N·m (8.67...12.12 lb·in), M5: 1.57...2.35 N·m (13.89...20.8 lb·in). Rockwell Automation Publication 700-TD552F-EN-P - January 2021 255 Relay and Timer Specifications 700-SN10 700-SN25 700-SN50 700-SN50HC 700-SN50VHC 67 12 47 45 27 28,5 Cat. No.700-SHTRMA 27,5 Cat. No. 700-SHCOV 256 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Load Connection · For an AC load, use a power supply that is rated at 50 Hz. or 60 Hz. The maximum operating frequency is 10 Hz. · The 700-SH has a built-in varistor for surge/inrush protection of AC loads. If additional suppression is required, connect an external varistor across the load device terminals. Select a varistor, which meets the load voltage condition that is outlined in the table. Load Voltage [V AC] 100...120 200...240 380...480 Varistor Voltage [V] 240...270 440...470 820...1000 Varistor Surge Resistance 1000 A min. TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001. Zero Cross Function An SSR with a zero cross function operates when an AC load voltage reaches the zero point or its vicinity. This reduces clicking noises when the load is switched and minimizes the influence of an inductive load, (such as, lamp, heater, or motor) on the power supply because the inrush current of the load is reduced. This can also minimize the scale of the inrush current protection circuit. Output (load voltage) Input ON OFF At a low applied voltage (for example, 24V AC) the load current is not fully supplied. When the unit is switched ON, the voltage required to power the unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however, will not create any serious problems. Loss time For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load. Input SSR Load Load power supply Rockwell Automation Publication 700-TD552F-EN-P - January 2021 257 Relay and Timer Specifications 700-SK Slim Line Relays · High-response speed models · Input sensor module to allow high voltage 100...240V AC or 12...24V DC sensor · Interface to low voltage (logic) device such as a PC output module for typical SSR applications · LED indicator · Input modules and output modules can be used with the 700-HN121 or 700-HN221 sockets Input/Sensor Module Input-to-Output Isolation Method Photocoupler Status Indicator Yes Response Frequency 10 Hz 1 kHz Logic Level Supply Voltage Supply Current 4...32V DC 0.1...100 mA Rated Input Sensor Voltage 100...240V AC (1) 12...24V DC (1) 47...63 Hz Cat. No. 700-SKICA18 700-SKICZ24 Output/SSR Module Input-to-Output Isolation Zero Cross Method Function Yes Phototriac No Photocoupler Not Applicable (1) 47...63 Hz Status Indicator Yes Output (Load) Max. Continuous Current and Rated Voltage Range 2 A @ 100...240V AC (1) 2 A @ 5...48V DC 1.5 A @ 48...200V DC Rated Input Control Voltage 5...24V DC Cat. No. 700-SKOZ2Z25 700-SKON2Z25 700-SKOC2Z25 700-SKOC1Z25 Accessories - 700-SK Relays Photo Description Pcs./Pkg. Cat. No. Screw Terminal Socket -- Panel or DIN Rail Mounting 5-blade miniature socket with 10 A rating for use with 1pole, 700-HK relays. Accepts forked lug conductors. Socket includes a retainer clip. 10 700-HN121 DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m 10 Pre-Printed Identification Tags -- contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR...9CR, TR...9TR, M...9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy 10 placement on relays. Blank Identification Tags -- contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 199-DR1 700-N40 700-N41 258 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Specifications - 700-SK Relays Input Sensor Module Input Sensor Ratings Cat. No. 700-SKICZ24 700-SKICA18 Rated Input Voltage 12...24V DC 100...240V AC Max. Operating Input Voltage Range 6.6...32V DC 60...264V AC Input Current 8 mA max. 15 mA max. Pick-up Voltage 6.6V DC max. 60V AC max. Drop-out Voltage 3.6V DC min. 20V AC min. Output Logic Ratings 700-SKICZ24 700-SKICA18 Cat. No. Characteristics Logic Level Supply Voltage 4...32V DC Logic Level Supply Current Draw 0.1...100 mA Description Pick-up time Drop-out time Response frequency Output ON voltage drop Leakage current (from SSR) Output VDRM, VCEO (V) Output di/dt (A/uS) Output dv/dt (V/uS) Output I2t (A2S) Output Tj (°C) Max. Insulation Resistance Dielectric Strength Vibration Resistance (Max.) Shock Resistance (Max.) Ambient Temperature Operating Storage Standards Compliance Certifications Ambient humidity Operating Weight Cat. No. 700-SKICA18 Cat. No. 700-SKICZ24 20 ms max. 0.1 ms max. 20 ms max. 0.1 ms max. 10 Hz 100 Hz 1.6V max. 5 A max. 80 (ref. value) 80 (ref. value) -- -- -- -- -- -- 150 150 100 M min. between input and output 4000V AC, 50/60 Hz for 1 min between input and output 10...55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s(100 G) 30...+80 °C (22...+176 °F) with no icing or condensation 30...+100 °C (22...+212 °F) with no icing or condensation UL 508, CSA C22.2 No. 14, EN/IEC 60950 cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified 45...85% (no condensation) Approx. 18 g Output SSR Module Control/Input Ratings Cat. No. Rated Control Voltage 700-SKOZ2Z25 700-SKON2Z25 700-SKOC2Z25 700-SKOC1Z25 5...24V DC Max. Operating Control Voltage Range 4...32V DC Max. Reverse Control Voltage -32V DC Impedance (1) Pick-up Voltage Drop-out Voltage 15 mA max. at 25 °C (77 °F) 8 mA max. 4V DC max. 1V DC min. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 259 Relay and Timer Specifications Load/Output Ratings Cat. No. 700-SKOZ2Z25 700-SKON2Z25 700-SKOC2Z25 700-SKOC1Z25 Rated Load Voltage 100...240V AC 5...48V DC 48...200V DC Maximum Load Voltage Range 75...264V AC 4...60V DC 40...200V DC Continuous Load Current (Resistive) [A] Min. Max. (2) 0.05 2 0.1 2 0.1 1.5 (1) With a constant current input system. SSR impedance varies with a change in input voltage. (2) See Load Current Versus Ambient Temperature Characteristics for additional details. (3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See the "Inrush Current Resistivity"graphs on page 126 for more details. Characteristics Max. Inrush Current (3) 30 A (@50/60 Hz, One cycle) 8 A (10 ms) 8 A (10 ms) Description Cat. No. 700-SKOZ2Z25 Cat. No. 700-SKON2Z25 Cat. No. 700-SKOC2Z25 Cat. No. 700-SKOC1Z25 Load Switching Method/Device Pick-up Time Drop-out Time Triac 1/2 cycle of load power source cycle time (1) + 1 ms max. 1/2 of load power source cycle time (1) + 1 ms max. Transistor 1 ms max. 2 ms max. Response Frequency 20 Hz 100 Hz Output ON Voltage Drop 1.6V max. 2.5V max. Leakage Current (from SSR) 1.5 mA max. 1 mA max. Output VDRM, VCEO (V) Output di/dt (A/uS) 600 (ref.value) 30 600 (ref.value) 30 80 (ref.value) -- 400 (ref.value) -- Output dv/dt (V/uS) Output I2t (A2S) 300 300 -- -- 10.4 10.4 -- -- Output Tj (°C) Max. Insulation Resistance 125 125 150 150 100 M min. between input and output Dielectric Strength 4000V AC, 50/60 Hz for 1 min between input and output Vibration Resistance (Max.) Shock Resistance (Max.) 10...55 Hz, 1.5 mm double amplitude (10 G) 1000 m/s2 (100 G) Ambient Temperature Operating Storage 30...+80 °C (22...+176 °F) with no icing or condensation 30...+100 °C (22...+212 °F) with no icing or condensation Standards Compliance UL 508, CSA C22.2 No. 14, EN/IEC 60950 Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified Ambient Humidity Operating 45...85% (no condensation) Weight Approx. 18 g (1) 60 Hz cycle time = 16.6 ms, 50 Hz cycle time = 20 ms. Load Current vs. Ambient Temperature Characteristics For 2 A Versions Maximum Load Current (A) -20 0 20 40 60 80 100 Maximum Load Current (A) -20 0 20 40 60 80 100 2 1.5 1 0.5 Ambient Temperature [° C] 2 1.5 1 0.5 Ambient Temperature [° C] 260 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Relay and Timer Specifications Inrush Current (A) 10 30 50 100 200 500 1000 5000 Inrush Current (A) 10 30 50 100 300 500 1000 2000 Inrush Current (A) 10 30 50 100 300 500 1000 2000 Inrush Current Resistivity (2) 700-SKOZ/SKON 30 20 10 700-SKOC2 10 9 8 7 6 5 4 3 2 1 0 700-SKOZ/SKOC1 10 9 8 7 6 5 4 3 2 1 0 Energizing Time (ms) Energizing Time (ms) Energizing Time (ms) (2) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2...5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. Dimensions - 700-SK Relays All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not to be used for manufacturing purposes. IMPORTANT The input module (700-SKI) and output module (700-SKO) are compatible with the Cat. No. 700-HN121 socket. 29 max. 1 0.5 4.75 5.2 3 4 9.6 17.4 15 13 max. 4 10 28 max. 2 20 5 7.5 4.7 0.5 4.75 Terminal Arrangement/ Internal Connections (Bottom View) (+) 3 () 4 Load Input 1 5 () (+) Application Considerations of the700-SK Relay Connection For DC load switching, 700-SK SSR will operate properly if the load is connected to either the positive or negative SSR load terminal. The load can be connected to either positive or negative output terminals of the SSR. Protective Element (to extend SSR life) Since the SSR does not incorporate a surge absorption component, be sure to connect a surge absorption component when using the SSR to control an inductive load. TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 261 Relay and Timer Specifications Notes: 262 Rockwell Automation Publication 700-TD552F-EN-P - January 2021 Additional Resources Relay and Timer Specifications Technical Data These documents contain additional information concerning related products from Rockwell Automation. Resource General Purpose, Interposing, Solid-State and Specialty Relays Brochure publication 700-BR018 Solid-state Relay Application Guide, publication 700-AT001 EtherNet/IP Network Devices User Manual, ENET-UM006 Ethernet Reference Manual, ENET-RM002 System Security Design Guidelines Reference Manual, SECURE-RM001 Industrial Components Preventive Maintenance, Enclosures, and Contact Ratings Specifications, publication IC-TD002 Safety Guidelines for the Application, Installation, and Maintenance of Solid-state Control, publication SGI-1.1 Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website, rok.auto/certifications. Description Provides product overview and applications for Bul 700 relay line. Provides methods for applying and troubleshooting Solid-state relays. Describes how to configure and use EtherNet/IP devices to communicate on the EtherNet/IP network. Describes basic Ethernet concepts, infrastructure components, and infrastructure features. Provides guidance on how to conduct security assessments, implement Rockwell Automation products in a secure system, harden the control system, manage user access, and dispose of equipment. Provides a quick reference tool for Allen-Bradley industrial automation controls and assemblies. Designed to harmonize with NEMA Standards Publication No. ICS 1.1-1987 and provides general guidelines for the application, installation, and maintenance of solid-state control in the form of individual devices or packaged assemblies incorporating solid-state components. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at rok.auto/literature. Rockwell Automation Publication 700-TD552F-EN-P - January 2021 263 Rockwell Automation Support Use these resources to access support information. Technical Support Center Knowledgebase Local Technical Support Phone Numbers Literature Library Product Compatibility and Download Center (PCDC) Find help with how-to videos, FAQs, chat, user forums, and product notification updates. Access Knowledgebase articles. Locate the telephone number for your country. Find installation instructions, manuals, brochures, and technical data publications. Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes. rok.auto/support rok.auto/knowledgebase rok.auto/phonesupport rok.auto/literature rok.auto/pcdc Documentation Feedback Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback. Allen-Bradley, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Rockwell Otomasyon Ticaret A.. Kar Plaza Merkezi E Blok Kat:6 34752, çerenköy, stanbul, Tel: +90 (216) 5698400 EEE Yönetmeliine Uygundur Publication 700-TD552F-EN-P - January 2021 Supersedes Publication 700-TD552E-EN-P - June 2020 Copyright © 2021 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Acrobat Distiller 11.0 (Windows)