Instruction Manual for ACURITE models including: Professional Weather Center, 01506, 01524, 01534

Professional Weather Center 01506 / 01524 / 01534 Instructions

professional, weather, center, professional

AcuRite

Professional Weather Center - AcuRite

possible product performance, please read this manual in its entirety . and retain it for future reference. Unpacking Instructions . Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove. Package Contents. 1. Display with Tabletop Stand 2. 5-in-1 Sensor . Sensor Mounting ...

Professional Weather Center 01506 / 01524 / 01534 ... - AcuRite

Self-Calibrating Forecasting pulls data from your 5-in-1 sensor to generate your personal forecast. 9. Auto or Manual Pressure Mode. Indicates pressure mode ...

Professional Weather Center 01506 / 01524 / 01534 Instructions

5. The cup of water should take more than 20 minutes to empty; a quicker period will result in inaccurate calibration. Try to simulate a normal steady rainfall. When cup is empty of water, display unit should register 1.06”.

Not Your Device? Search For Manuals / Datasheets:

File Info : application/pdf, 20 Pages, 2.42MB

Document
01506-01524-01534-instructions
Instruction Manual
Professional Weather Center
model 01506 / 01524 / 01534

CONTENTS
Unpacking Instructions ........... 2 Package Contents .................. 2 Product Registration ............... 2 Features & Benefits: 5-in-1....... 3 Features: Display ................... 4 Back of Display...................... 6 Setup .................................... 7 5-in-1 Sensor Setup ................ 7 Display Setup ........................ 8 Set the Time, Date & Units ...... 9 Backlight Settings ................... 9

Placement Guidelines ............10 5-in-1 Sensor Installation........ 11 Using the Weather Center .....12 Rainfall Tracking ...................13 Troubleshooting ....................14 Care & Maintenance.............16 Calibration ...........................16 Specifications........................18 FCC Information ...................18 Customer Support .................19 Warranty..............................19

Questions? Contact Customer Support at
(877) 221-1252 or visit www.AcuRite.com.

SAVE THIS MANUAL FOR FUTURE REFERENCE.

Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.
Package Contents
1. Display with Tabletop Stand 2. 5-in-1 Sensor 3. Sensor Mounting Bracket 4. Mounting Hardware 5. Power Adapter 6. Instruction Manual

IMPORTANT
PRODUCT REGISTRATION Register online
to receive 1 year warranty protection
www.AcuRite.com

PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
Archive:l Products
Register a Product

2

Features & Benefits
1 2

7 9

11 3 4 5 8
6
10

5-IN-1 SENSOR
1. Rainfall Collector Funnel
2. Solar Cell Panel Converts sunlight into power to run internal aspirating fan.
Internal Aspirating Fan (not shown) Draws ambient air into sensor to reduce solar radiation heating, resulting in more accurate temperature measurement.
3. A-B-C Switch ID code that must match display's A-B-C switch to ensure units synchronize.
4. Battery Compartment

5. Temperature & Humidity Sensors (internal)

6. Mounting Bracket

7. Wind Speed Anemometer

8. Wind Direction Vane

9. Mounting Bracket

10. Mounting Hardware

Includes anchors & screws.

Qty Diameter Length

5

#4

3/4"

1

#4

1/2"

1

#6

1/2"

11. Debris Filter
Pre-installed to prevent debris from entering the rain gauge.

3

Features & Benefits
Display

27 26

31 30 29 28

25 24

31

1 ,cD,~~hG:

23

2

TD O OR

22

3

MPH

4

:I  % -j'\w
:--J  ~h ... A2VlG". -----~

.-.- SE~
.,,,,.;;28 ill PEAK\

J-
.._



%HIG

~
LOW

21

5 ~l

 /2 17 12:38P_=_==!,=M1=

20

6

AUTO DIM

RAINFALLilll

19

7

18

17 8

16 15

9

14

10

11

12

13

4

1. Current Outdoor Temperature Arrow icon indicates direction the temperature is trending.
2. Outdoor Sensor Signal Strength
3. Sensor Low Battery Indicator
4. Current Outdoor Humidity Arrow icon indicates the direction the humidity is trending.
5. Date
6. Weather Select Displays heat index, dew point, wind chill, "feels like" calculations, days with rain this month, and days since last rain.
7. Learning Mode Icon Disappears after weather forecast self-calibration is complete.
8. 12 to 24 Hour Weather Forecast Self-Calibrating Forecasting pulls data from your 5-in-1 sensor to generate your personal forecast.
9. Auto or Manual Pressure Mode Indicates pressure mode preference.
AUTO Pressure Mode Pressure will self-calibrate over a 14 day Learning Mode. MANUAL Pressure Mode Indicates raw pressure value, no adjustment for sea level (can be calibrated).
10. Barometric Pressure Arrow icon indicates the direction the pressure is trending.
11. SELECT Button Press to change the Weather Select category data being display.
12. V, SET, T Buttons For setup preferences and access to historical records.
13. RAINFALL Button Press to display historical rainfall data.

14. Date Stamp for Historical Rainfall Data (#15)
15. Historical Rainfall Totals
16. Storm Alert Indicator Activates when barometric pressure drops.
17. Current Rainfall Total Rainfall recorded since 12:00am.
18. AUTO DIM Indicator Indicates display is in auto-dimming brightness mode (see page 9).
19. Rainfall Alert Indicator Indicates rainfall of more than 1" (25 mm) of rain in 2 hours or less.
20. Clock
21. Current Indoor Humidity Arrow icon indicates the direction the humidity is trending.
22. Display Low Battery Indicator
23. Current Indoor Temperature Arrow icon indicates the direction the temperature is trending.
24. Peak Wind Speed Highest speed from past 60 minutes.
25. Wind Speed Alert Indicator Activates when wind speed is over 50 mph.
26. Current Wind Speed
27. -·.8r- Button
Dimmer control while using power adapter. Activates momentary backlight while on battery power.
28. Current Wind Direction
29. Previous 2 Wind Directions
30. Average Wind Speed Average of all speeds over the past 2 minutes.
31. HIGH/LOW Indicators HIGH indicates a high record is shown on the display. LOW indicates a low record is shown.

5

Back of Display 1

2
3 6 5

4 7

BACK OF DISPLAY
1. Integrated Hang Hole For easy wall mounting.
2. Plug-in for Power Adapter
3. Battery Compartment
4. Removable Tabletop Stand
5. CLEAR ALL/RESET Button Press to clear record currently being viewed. Press AND HOLD for more than 10 seconds for full reset to factory defaults.

6. A-B-C Switch ID code that must match 5-in-1 sensor's A-B-C switch to ensure units synchronize.
7. Power Adapter
8. Battery Compartment Cover (not shown)

6

SETUP

5-in-1 Sensor Setup

·1 Set the A-B-C Switch Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select

cause alkaline batteries to function improperly. Use lithium batteries in the 5-in-1 sensor for temperatures
below -4ºF / -20ºC.

the same letter choices for both the 1. Slide off the battery

sensor and the display in order for

compartment cover.

the units to synchronize.
·2 Install or Replace Batteries Batteries MUST be installed for this product to operate. AcuRite

2. Insert 4 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.

recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.

3. Replace the battery cover.
·3 Remove Rain Gauge Stabilizer Locate and remove the rain gauge

The 5-in-1 sensor requires lithium batteries in low temperature conditions. Cold temperatures can

stabilizer (plastic tab) taped into the bottom of the sensor. The rain
gauge will not function until this is removed.

A B C
·1 A-B-C Switch Set to match display
·2 Install Batteries 4 AA Batteries

3 Rain Gauge Stabilizer
Remove and discard
7

Display Setup

AcuRite recommends high quality alkaline batteries for the best product

performance. Heavy duty or rechargeable batteries are not recommended.

1 Set the A-B-C Switch
· · The A-B-C switch is located inside the battery compartment. It can be set to A, B or C. However, you must · select the same letter choices for

2 Plug Power Adapter into Electrical Outlet
3 Install or Replace Batteries (optional)

both the sensor and the display in order for the units to synchronize.

Insert 6 x AA alkaline batteries into the battery compartment,

as shown. Follow the polarity

1 ABC

(+/-) diagram in the battery compartment.

3 Install Backup Batteries
6 AA Batteries (optional)

2 Plug in Power Adapter
IMPORTANT: Batteries are a backup power source to preserve records in the event of a power outage. Power adapter is recommended as the primary power source to enjoy the full functionality of this product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.
8

Set the Time, Date & Units
Press the "SET" button, located on the front of the display, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.
To adjust the currently selected (flashing) item, press and release the "T" or
"V" buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the "SET" button again to adjust the next preference. The preference set order is as follows:
CLOCK HOUR CLOCK MINUTE CALENDAR MONTH CALENDAR DATE CALENDAR YEAR TEMPERATURE UNITS (ºF or ºC) WIND UNITS (MPH, KPH, or Knots) RAIN UNITS (inches or mm) PRESSURE UNITS (inHg or hPa)
You will automatically exit SET MODE if no buttons are pressed for 20 seconds. Enter setup mode at any time by pressing the "SET" button.

Display Backlight Settings
This weather station's display features three different lighting settings: High (100%) brightness, Medium (60%) brightness and Low (30%) brightness.

Using battery power seconds by pressing

tahleon"e-·.8,r-th"ebbuattcoknl.ight

is

available

momentarily

for

10

When 100%

bdrisigphlatnyeisssp. oPwreesrse"d-·-8w.-ri"thbtuhtetopnoownecreatdoadpitmert,ob6a0ck%ligbhrtigrehmtnaeisnss;

on at press

again to dim to 30%, press a 3rd time to enter "AUTO DIM" mode. "AUTO

DIM" appears below time.

AUTO DIM MODE: Automatically adjusts display brightness based on time of day & year.

MARCH 11- NOVEMBER 4

6:00 a.m. - 9:00 p.m. = 100% brightness

9:01 p.m. - 5:59 a.m.= 30% brightness

NOVEMBER 5 - MARCH 10

7:30 a.m. - 7:00 p.m.= 100% brightness

7:01 p.m. - 7:29 a.m. = 30% brightness

9

Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display and the sensor are critical to the accuracy and performance of this product.

Display Placement
Place the display in a dry area free of dirt and dust. To ensure accurate temperature measurement, place out of direct sunlight and away from heat sources or vents. Display stands upright for tabletop use or is wall-mountable.

5-in-1 Sensor Placement
The 5-in-1 sensor is designed to remain outdoors all year long. Choose an open location with no obstructions above or around the sensor for the most accurate measurements.

Important Placement Guidelines
Display and sensor must be within 330 feet (100 m) of each other.

MAXIMIZE WIRELESS RANGE
Place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.

PREVENT WIRELESS INTERFERENCE
Place both units at least 3 feet (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).

LOCATE AWAY FROM HEAT SOURCES
Position sensor away from heaters, air conditioners, chimneys, exhaust vents, asphalt and concrete (surfaces that radiate heat).

LOCATE AWAY FROM HUMIDITY SOURCES
Avoid installing the sensor near pools, spas, or other bodies of water. Water sources may impact humidity accuracy.

LOCATE AWAY FROM SPRINKLER HEADS
DO NOT install the sensor where it will be sprayed by a sprinkler system. This may force water inside the sensor.

LOCATE AWAY FROM WIND & RAIN OBSTRUCTIONS
DO NOT mount the sensor with obstructions around it. Consider a location that is a wide open area, with few structures around to ensure accurate measurements.

Visit us online to view installation photos and
video, or learn more about AcuRite technology: www.AcuRite.com/5in1

View Video

10

5-in-1 Sensor Installation Guidelines

INSTALLATION HEIGHT Mount the sensor at a minimum height of 5 feet (1.5 meters) off the ground, in an open area. Higher is better for wind
measurements - The National Weather Service recommends 33 feet high!

MOUNTING OPTIONS The included mounting bracket it designed to screw

directly onto wooden posts or surfaces that are 2x4 or larger. The sensor can

also be mounted directly to common 3/4" steel pipe (available at hardware

stores and home centers).

LEVEL INSTALLATION Use the bubble level (included on top of sensor) to

NO OBSTRUCTIONS ABOVE OR AROUND

ensure level installation for accurate wind measurement.

SOUTH

SOLAR CELL INSTALLATION Install the

sensor with the solar cell facing SOUTH.

This ensures the cell receives as much sun

as possible and orients wind direction.

5-in-1 Sensor Installation
1. Fasten mounting base (included) to a post or pole (not included) using the 4 longer screws included in the hardware bag.

(1.5 meters)

2. Insert the mounting base into the hole on the bottom of the sensor.

3. Make sure the arrows on the top of the sensor are pointed in the proper
direction and the bubble level is centered. The solar cell should be facing south to properly orient the wind direction.

4. Fasten the sensor into the mounting base using the 2 shorter screws included in the hardware bag.

The 5-in-1 sensor is now ready to use.

Clear Data Collected During Installation When installation is complete, press and HOLD "CLEAR ALL/RESET" button, located on the back of the display inside the battery compartment, to clear erroneous data from the display.
Basic Setup is Complete
The 5-in-1 sensor will now synchronize with the display. It may take a few minutes for synchronization to complete. If both or one of the units appear to be functioning improperly, please refer to the troubleshooting section.

11

OPERATION

Using the Professional Weather Center
Learning Mode
Self-Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction.
Weather Forecast
AcuRite's patented Self-Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard. It generates a forecast with pinpoint accuracy personalized for your exact location.

STORMY & WINDY

SNOW LIKELY

SNOW / RAIN MIX LIKELY

CHANCE OF RAIN

CLOUDY

(flashing=stormy)

~ . .. . . . ..

It Joi X

)l

)';

X

)I;

View the complete list of icons at www.AcuRite.com/acurite-icons

Weather Select
Weather Select displays data including wind chill, dew point, heat index, feels like, days with rain this month, and days since last recorded rainfall. To change the "Weather Select" category shown, press the "SELECT" button on the front of the display.
Barometric Pressure
Subtle variations in barometric pressure greatly affect the weather. This weather station displays the current pressure with an arrow icon to indicate the direction the pressure is trending (FALLING, STEADY, or RISING).
High & Low Records
Today's high and low records are displayed for indoor and outdoor temperature and humidity. Today's records automatically clear at 12:00am
midnight every day. View today's high or low records by pressing the "T" or
"V" buttons. Press and release again to view all-time records with a timestamp for when each record was set.
To manually clear a recorded value, press and release the "CLEAR ALL/RESET" button located in the battery compartment, while viewing the record you wish to clear. Dashes will display to confirm you have cleared the record(s).

12

Rainfall Tracking
This weather station features enhanced tracking of historical rainfall data. Rain accumulation data is recorded for today, over all-time, by year, by month, and by rainfall event.

Press the "RAINFALL" button to review rainfall records. The on the display while historical data is being viewed.

icon is shown

Records are shown in the following order:

PREVIOUS RAINFALL #1* PREVIOUS RAINFALL #2* PREVIOUS RAINFALL #3* CURRENT MONTH TOTAL RAINFALL PREVIOUS MONTH TOTAL RAINFALL 2 MONTHS AGO TOTAL RAINFALL CURRENT YEAR TOTAL RAINFALL PREVIOUS YEAR TOTAL RAINFALL ALL-TIME TOTAL RAINFALL (date shown is start date of the all-time total;
the date the display was powered on)

RAINFALL
'---TODAY---' ,- PREVIOUESVENTS---.
l.2S
Cl 9/ 17/l7
TOTAL RAINFALL FOR DATE SHOWN

RAINFALL
'---TODAY---' ,- PREVIOUESVENTS---.
6.92:~
Cl 9/ / 17
TOTAL RAINFALL FOR MONTH SHOWN

RAINFALL

RAINFALL

RAINFALL

'---TODAY---' ,- PREVIOUESVENTS---.
36.SSTOTAYLR.
Cl I / 17
CURRENT YEAR TOTAL RAINFALL

'---TODAY___, ,- PREVIOUESVENTS---.
'-181,3TOT:-
Cl I / 16
PREVIOUS YEAR TOTAL RAINFALL

'---TODAY---' ,- PREVIOUESVENTS---.
8'-1.68~-
Cl I/ 1/ 17
ALL-TIME TOTAL RAINFALL

*Previous rainfall is the amount of rain recorded from 12:00am to 11:59pm on the date shown.

13

Troubleshooting
Problem

Possible Solution

No outdoor sensor reception
Tullno bars

· Relocate the display and/or the 5-in-1 sensor. The units must be within 330 ft (100 m) of each other.
· Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).
· Use standard alkaline batteries (or lithium batteries in sensor when temperature is below -4ºF/-20ºC). Do not use heavy duty or rechargeable batteries. NOTE: It may take up to 20 minutes for display and sensor to synchronize after batteries are replaced.
· Synchronize the units:
1. Bring both the sensor and display indoors and remove batteries from each.
2. Reinstall batteries in outdoor sensor.
3. Reinstall batteries in display.
4. Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection.

Outdoor temperature is flashing or showing dashes

Flashing of the outdoor temperature may be an indication of wireless interference.
· Make sure the A-B-C switch in the battery compartments of both the display and sensor are switched to the same letter. You may choose A, B or C; but both units must match to sync up. Sometimes changing to a different channel can help.

Inaccurate forecast

· Weather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions.
· Has Learning Mode icon disappeared from the display? Learning Mode must complete before forecast and pressure will be accurate.
· Allow unit to run continuously for 33 days. Battery removal or resetting the display will restart Learning Mode. After 14 days, forecast should be fairly accurate, however Learning Mode calibrates for a total of 33 days.

14

Troubleshooting
Problem
Inaccurate temperature or
humidity

Possible Solution
· Make sure both the display and 5-in-1 sensor are placed away from any heat sources or vents (see page 10).
· Make sure both units are positioned away from moisture sources (see page 10).
· Make sure 5-in-1 sensor is mounted at least 5 ft off of the ground.
· Calibrate indoor and outdoor temperature and humidity (see page 16).

No rainfall
Inaccurate wind readings
Display screen not working

· Check to ensure the rain gauge stabilizer (plastic tab) has been removed from the bottom of the sensor (see page 7).
· Clear debris, such as leaves, out of the rain collector funnel and debris screen.
· Calibrate the Rain Gauge (see page 17).
· Verify the sensor's internal tipping lever is moving freely by dripping a little water through the rain collector. You should hear the lever tipping. If you do not hear it, you may need to clean inside the sensor. Video available at www.acurite.com/5in1
· What is wind reading being compared to? Pro weather stations are typically mounted at 30 ft high or more. Make sure to compare data using a sensor positioned at the same mounting height.
· Check location of the sensor. Ensure it's mounted a minimum of 5 ft in the air with no obstructions around it (within several feet).
·Ensure wind cups are spinning freely. If they hesitate or stop try lubricating with graphite powder or spray lubricant.
· Check that the power adapter or batteries are installed correctly. Batteries may need to be replaced.
· Reset the display by pressing and HOLDING the "CLEAR ALL/RESET" button located in the battery compartment of the display button for more than 10 seconds. Date and time will need to be entered after a reset.

If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call (877) 221-1252 for assistance.

15

Care & Maintenance
Display Care Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air.
5-in-1 Sensor Care Clean the Sensor Clean with a soft damp cloth. Do not use caustic cleaners or abrasives that will mar the polished surfaces of the rain collection funnel or the solar cell. Scratches will result in decreased performance and reliability.
Insect Prevention Insects may cause obstructions and interrupt data by nesting in or on the 5-in-1 sensor. To limit this problem, spray the OUTSIDE of the sensor with a household insect repellent. Consult the insect repellent instructions prior to use.
Snow & Freezing Weather The 5-in-1 sensor will not be damaged by freezing conditions. NOTE: If the rain collector cup fills with snow and then melts, it will register as rain on the display.
Clean the Rain Collector Cup Remove and empty rain collector debris filter. The debris filter is located in the rain collector funnel. Remove from the top by gently squeezing and pulling out.
Clean the Wind Vane & Anemometer Remove foreign matter from the outside of the sensor for free movement of the wind vane and anemometer. If needed, use a small amount of spray lubricant, clear silicone or graphite powder on the anemometer for improved movement.
Calibration
The indoor / outdoor temperature and humidity readings, and barometric pressure can be calibrated on the display to improve accuracy. Calibration can improve accuracy when sensor placement or environmental factors impact the data accuracy.
1. To access calibration mode, press AND HOLD the "T" and "V" buttons
simultaneously for at least 5 seconds.
2. To adjust the currently selected (flashing) item, press and release the "T"
or "V" buttons to calibrate the data value higher or lower from the actual reading.
3. To save your adjustments, press and release the " SET " button to adjust the next preference. The ",.e " icon will remain illuminated next to calibrated values.
16

The preference set order is as follows:
OUTDOOR TEMPERATURE OUTDOOR HUMIDITY INDOOR TEMPERATURE INDOOR HUMIDITY BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)*
*To change from AUTO to MANUAL pressure mode and vice versa, press AND HOLD the " SET " button for at least 10 seconds. The display indicates the current pressure mode selected,"AUTO" or "MANUAL".
After 20 seconds of inactivity, the display will save the adjustments and exit calibration mode. Note: Calibrations will be erased if the display is reset or if batteries are removed and the power adapter is unplugged.
Calibrate the Rain Gauge
The rain gauge on the 5-in-1 sensor can be calibrated to improve accuracy. Items Needed: 5-in-1 sensor, display, plastic cup, pin, screw driver
1. First, ensure 5-in-1 sensor is perfectly level using built-in bubble level.
2. Place display close so you can monitor it during calibration.
3. Make a pin hole in the bottom of a plastic cup. Hold the cup over the rain gauge and fill it with exactly 1 cup (8oz) of water, allowing the water to drip into the rain gauge. You should hear the internal buckets tip and see water drain through the rain gauge.
4. A few seconds after each bucket tip, the display unit displays rainfall in approximately 0.01" or more increments.
5. The cup of water should take more than 20 minutes to empty; a quicker period will result in inaccurate calibration. Try to simulate a normal steady rainfall. When cup is empty of water, display unit should register 1.06".
Tips
· There should be nearly an equal number of water drops (about 25 water drops) between bucket tips. If not, adjust the calibration screws on the bottom of the 5-in-1 sensor until an equal number of water drops are tipping the buckets. Then, restart the calibration procedure.
· If you don't hear the buckets tipping and see water dripping alternately out of each drain, there may be an issue with the rain gauge or it's adjustment. See Troubleshooting on page 15.
Adjustment
If the rain gauge doesn't register close to 1.06", make an EQUAL adjustment to the two calibration screws on the bottom of the 5-in-1 sensor. Turning screws clockwise increases rainfall; counter clockwise decreases rainfall.
17

· To adjust the rainfall reading by 2% turn both screws 1/8 of a turn. · To adjust the rainfall reading by 4% turn both screws 1/4 of a turn. · To adjust the rainfall reading by 8% turn both screws 1/2 of a turn.
Watch the video at: www.acurite.com/5in1

Specifications

TEMPERATURE RANGE Outdoor: -40ºF to 158ºF; -40ºC to 70ºC

Indoor: 32ºF to 122ºF; 0ºC to 50ºC

HUMIDITY RANGE

Outdoor: 1% to 99%

WIND SPEED

Indoor: 1% to 99% 0 to 99 mph; 0 to 159 kph

WIND DIRECTION INDICATORS

16 points

RAINFALL MEASUREMENT 0.01 inches (0.25 mm) and up

WIRELESS RANGE

330ft / 100m depending on home construction materials

OPERATING FREQUENCY POWER

433 MHz
Display: 4.5V, 250mA power adapter 6 x AA alkaline batteries (optional)

DATA REPORTING

Sensor: 4 x AA alkaline or lithium batteries
Wind Speed: 18 second updates; Direction: 30 seconds Outdoor temperature & humidity: 36 second updates Indoor temperature & humidity: 60 second updates

FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions: 1- This device may NOT cause harmful interference, and 2- This device must accept any interference received, including interference that may cause undesired operation. WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and the receiver.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference received, including interference that may cause undesired operation of the device.

18

Customer Support
AcuRite customer support is committed to providing you with best-inclass service. For assistance, please have the model number of this
product available and contact us in any of the following ways:

(877) 221-1252

Visit us at www.AcuRite.com

 Installation Videos

 Register your Product

 Instruction Manuals

 Support User Forum

 Replacement Parts

 Submit Feedback & Ideas

IMPORTANT

PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE

PRODUCT REGISTRATION Register online
to receive 1 year warranty protection
www.AcuRite.com

Archi~ed Products
Register a Product

Limited 1 Year Warranty
AcuRite is a wholly owned subsidiary of Chaney Instrument Company. For purchases of AcuRite products, AcuRite provides the benefits and services set forth herein. For purchases of Chaney products, Chaney provides the benefits and services set forth herein.
We warrant that all products we manufacture under this warranty are of good material and workmanship and, when properly installed and operated, will be free of defects for a period of one year from the date of purchase.
Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by us, and at our sole option, be repaired or replaced by us. Transportation costs and charges for returned goods shall be paid for by the purchaser. We hereby disclaim all responsibility for such transportation costs and charges. This warranty will not be breached, and we will give no credit for products which have received normal wear and tear not affecting the functionality of the product, been damaged (including by acts of nature), tampered, abused, improperly installed, or repaired or altered by others than our authorized representatives.
Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). If we determine that repair or replacement is not feasible, we may, at our option, refund the amount of the original purchase price
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY
FOR THE PRODUCTS AND IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER WARRANTIES
OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN
ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT
LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY
AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE.

We expressly disclaim all liability for special, consequential, or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
We further disclaim liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of our products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to bind us to any other obligation or liability in connection with the sale of our products. Furthermore, no person, firm or corporation is authorized to modify or waive the terms of this warranty unless done in writing and signed by a duly authorized agent of ours.
In no case shall our liability for any claim relating to our products, your purchase or your use thereof, exceed the original purchase price paid for the product.
Applicability of Policy
This Return, Refund, and Warranty Policy applies only to purchases made in the United States and Canada. For purchases made in a country other than the United States or Canada, please consult the policies applicable to the country in which you made your purchase.
Additionally, this Policy applies only to the original purchaser of our products. We do cannot and do not offer any return, refund, or warranty services if you buy products used or from resale sites such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy is governed by the laws of the United States and the State of Wisconsin. Any dispute relating to this Policy shall be brought exclusively in the federal or State courts having jurisdiction in Walworth County, Wisconsin; and purchaser consents to jurisdiction within the State of Wisconsin.

19

ACU

 RITE®

Weather Stations

Temperature & Humidity

Weather Alert Radio

Kitchen Thermometers
& Timers

Clocks

It's More than Accurate, it's ACU>RITE.
AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to
Plan your day with confidenceTM.
www.AcuRite.com

01534DI INST 021216

©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.



References

Acrobat Pro DC 20 Paper Capture Plug-in