manual mapping of Modbus points required. 65. 800.354.8556 | 1 503.598.4564 | sales@veris.com | intl@veris.com | veris.com.
ABOUT US. Veris Industries is an energy and environmental sensors partner that provides quality products for commercial HVAC and other automation applications. Since its founding in 1992, Veris...
We've got your back 2021 Energy and Environmental Sensors POWER MONITORING SINGLE-CIRCUIT POWER MONITORING MULTI-CIRCUIT POWER METERING CTS NETWORK INTEGRATION POWER ACCESSORIES AIR QUALITY/GAS DETECTION FLOW MONITORING HUMIDITY MONITORING LEAK DETECTION PRESSURE MONITORING TEMPERATURE MONITORING OCCUPANCY SENSORS SETPOINT DEVICES CURRENT MONITORING RELAYS POWER SOURCES ABOUT US Veris Industries is an energy and environmental sensors partner that provides quality products for commercial HVAC and other automation applications. Since its founding in 1992, Veris has built a strong reputation for dependable products and impeccable customer service. We offer complete lines of innovative power monitoring and environmental sensing products including air quality sensors, current sensors, temperature sensors, pressure sensors, flow meters, power meters, leak detection, setpoint devices and more. Our long-lasting, reliable products are only part of the story. When you work with Veris, you'll have a knowledgeable expert just a phone call away at all times. Buying from Veris Online Has Never Been Easier! Visit our website to find exactly what you need any time of day or night. · Product Availability and Shipping Estimates · Order and Invoice History · Easy On-Site Search · Advanced Product Filtering · Detailed Product Comparison Tables · Chat and Contact Us · Technical Support Requests · And More! www.veris.com PRODUCT CATEGORIES Table of Contents POWER MONITORING ENVIRONMENTAL SENSORS MOTOR CONTROL POWER MONITORING 15 SINGLE-CIRCUIT POWER MONITORING 29 MULTI-CIRCUIT POWER 39 METERING CTS NETWORK 53 INTEGRATION POWER 69 ACCESSORIES AIR QUALITY/GAS 71 DETECTION FLOW 95 MONITORING HUMIDITY MONITORING 123 LEAK DETECTION 139 PRESSURE MONITORING 155 TEMPERATURE MONITORING 181 OCCUPANCY SENSORS 207 SETPOINT DEVICES 213 CURRENT MONITORING 235 RELAYS 281 POWER SOURCES 315 DATA CENTERS SERVER ENVIRONMENT Maintain a consistent environment aisle by aisle Occupancy Sensors MSX SERIES Page 209 Reduce energy consumption and control energy waste by lighting a room only when it's occupied. Humidity Sensors HW2 SERIES Page 125 High accuracy sensor provides an ideal operating environment for critical applications. A modern aesthetic and touchscreen display allow for optimal humidity control at zone level. Temperature Sensors TW2, TD SERIES Page 183 Monitor temperature at a zone level with high accuracy to provide an ideal environment. 1 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com SERVER PANELS & CRACS Protect critical equipment and ensure uptime POWER & ENERGY Monitor large loads transducers, UPSs, PDUs and RPPs DCIM Enhance data center infrastructure management with real-time energy information Liquid & Chemical Leak Detection LD SERIES & SC SERIES Page 141-145, 149 Complete leak detection systems protect expensive electronics from costly water damage. Monitor a single location or large area with reliable sensing devices and controller systems. Differential Pressure or Air Velocity Sensor PX3 SERIES Page 157 Precisely measure differential air pressure or velocity with the flip of a switch using Bluetooth® technology. Main Panel & Single-Circuit Power Metering E5X SERIES Page 23 DIN mounted power meter ideal for sub-metering individual loads where a local display is required. Energy Meters ENERCEPT FLEX E20 SERIES Page 19 Maximum retrofit flexibility. Monitor loads from 50 to 5000 A on the same rope style CT. Panelboard Monitoring E3X SERIES Page 35 Provides comprehensive monitoring of panelboards and RPPs with revenue-grade accuracy for new construction projects. Retrofit Panelboard Monitoring E31 SERIES Page 35 Provides comprehensive monitoring of panelboards and RPPs with revenue-grade accuracy for retrofit projects. Panelboard Monitoring E3X SERIES Page 35 Provides comprehensive monitoring of panelboards and RPPs with revenue-grade accuracy for new construction projects. Retrofit Panelboard Monitoring E31 SERIES Page 35 Provides comprehensive monitoring of panelboards and RPPs with revenue-grade accuracy for retrofit projects. Multi-Circuit Metering E34 SERIES Page 33 Monitor all PDU loads with a single device. Note: The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. Any use of such marks is under license. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com 2 FOOD RETAIL COOLING & REFRIGERATION Monitor temperature of walk-ins, pressure of parallel refrigerators and detect mechanical failures of compressors and motors Temperature Sensors T SERIES Page 191 Accurately monitor temperature in space, refrigeration case, walk-in cooler, freezer and hot water reclaim tank temperature. Gauge Pressure Sensors PG SERIES Page 175 Reliably monitor pressure in parallel refrigeration racks and hydraulic motors. Current Sensors H922 Page 265 Detect belt loss and mechanical failure in compressors with a selfpowered analog current sensor that provides accurate load trending information. 3 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com HVAC & PHYSICAL PLANT Energize lighting contactors, monitor cooling towers ENVIRONMENTS Regulate environments, efficiently and effectively MAIN POWER & SUB-METERING Monitor main power distribution, light panels and sub-metering Relays V100 SERIES Page 285 Energize lighting contactors with a pilot-duty relay in an easy-to-use nipple mount enclosure. Flow Meters SDI SERIES Page 97 Measure supply and discharge water to get credit on sewer bill for actual water discharged. Don't be billed for evaporated water. Humidity Sensors HW2 SERIES Page 125 Reduce compressor run time and glass door fogging with an accurate and easy-to-use humidity sensor. CO2 Sensors CW2 SERIES Page 73 Calling for fresh air only when CO2 levels are high saves energy. Make the CW2 Series part of your demand controlled ventilation strategy. Gas Detection CO, NO2 SENSORS Pages 85 & 87 Easy parking garage monitoring with the GWN and GWNP modular platforms. Monitor CO and NO2 separately or combined. Refrigerant Sensors Pages 85 & 87 Ideal for variable refrigerant flow, mechanical rooms, and occupied spaces. Energy Meters ENERCEPT FLEX E20 SERIES Page 21 Maximum retrofit flexibility. Monitor loads from 50 to 5000 A on the same rope style CT. Multi-Circuit Metering E34 SERIES Page 33 Monitor up to 28 3-phase loads with a single compact device. Saves cost on both equipment and installation. Main Panel & Single-Circuit Power Metering E5X SERIES Page 23 The E5X Series offers ultimate versatility in power monitoring with a wide choice in mounting options, inputs, outputs, and communication protocols including BACnet, LON, and Modbus. The meters are compact in size allowing multiple meters to be mounted in the same panel, saving installation time and costs. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com 4 HOSPITALS ROOM & PATIENT CARE Provide ideal environmental conditions while optimizing efficiency Occupancy Sensors MSX SERIES Page 209 Reduce energy consumption and control energy waste by lighting a room only when it's occupied. CO2 Sensors CW2 SERIES Page 73 Calling for fresh air only when CO2 levels are high saves energy. Make the CW2 Series part of your demand controlled ventilation strategy. Humidity Sensors HW2 SERIES Page 125 High accuracy sensor provides an ideal operating environment for critical applications. A modern aesthetic and touchscreen display allow for optimal humidity control at zone level. 5 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com HVAC & PHYSICAL PLANT Increase efficiency, extend safety POWER & ENERGY Quantify and qualify usage PARKING STRUCTURE & VEHICLE BAYS Monitor and balance risks Liquid & Chemical Leak Detection LD SERIES & SC SERIES Page 141-145, 149 Complete leak detection systems protect expensive electronics from costly water damage. Monitor a single location or large area with reliable sensing devices and controller systems. Flow Monitoring 380 SERIES Page 101 Metering of heated or chilled liquid, with a turbine flow meter and BTU transducer in one compact package. Current Monitoring H904 VFD SWITCH Page 251 Accurately and reliably monitor fan status. The H904 automatically compensates for the effects of frequency and amperage changes associated with VFDs, and features a self-adjusting trip point. Sub-Metering ENERCEPT FLEX E20 SERIES Page 19 Maximum retrofit flexibility. Monitor loads from 50 to 5,000 A on the same rope style CT. Gas Detection CO, NO2 SENSORS Pages 85 & 87 Easy parking garage monitoring with the GWN and GWNP modular platforms. Monitor CO and NO2 separately or combined. Communicating Thermostats VIC-VT8650 SERIES Page 223 Maximize system adaptability in rooftop unit control with BACnet, LON or wireless communication protocol. Main Panel & Single-Circuit Power Metering E5X SERIES Page 23 The E5X Series offers ultimate versatility in power monitoring with a wide choice in mounting options, inputs, outputs, and communication protocols including BACnet, LON, and Modbus. The meters are compact in size allowing multiple meters to be mounted in the same panel, saving installation time and costs. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com 6 INDUSTRIAL AUTOMATION WORKSPACE Maintain a comfortable environment without additional cost CO2 Sensors CW2 SERIES Page 73 Calling for fresh air only when CO2 levels are high saves energy. Make the CW2 Series part of your demand controlled ventilation strategy. Humidity Sensors HW2 SERIES Page 125 High accuracy sensor provides an ideal operating environment. A modern aesthetic and touchscreen display allow for optimal humidity control at zone level. Temperature Sensors TW2, TD SERIES Page 183 Monitor temperature at a zone level with high accuracy to provide an ideal environment. 7 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com BUILDING SAFETY & EFFICIENCY Monitor automated material handling, measure clean room pressure, control safety barriers Current Transducers H971 Page 273 Accurately monitor status of DC current loads. Avoid costly equipment damage and downtime. Differential Pressure or Air Velocity Sensor PX3 SERIES Page 157 Precisely measure differential air pressure or velocity with the flip of a switch using Bluetooth® technology. Relays V100 SERIES Page 285 Energize lighting contactors with a pilot-duty relay in an easy-to-use nipple mount enclosure. ENERGY & POWER USAGE MONITORING Monitor and meter power usage and heated or chilled liquids HVAC & PHYSICAL PLANT Detect leaks in sprinkler systems, measure chiller/boiler line pressure and enable rooftop unit control via sensors Flow Monitoring 380 SERIES Page 101 Metering of heated or chilled liquid, with a turbine flow meter and BTU transducer in one compact package. Communicating Thermostats VIC-VT8650 SERIES Page 223 Maximize system adaptability in rooftop unit control with BACnet, LON or wireless communication protocol. Sub-Metering ENERCEPT FLEX E20 SERIES Page 19 Maximum retrofit flexibility. Monitor loads from 50 to 5,000A on the same rope style CT. Main Panel & Single-Circuit Power Metering E5X SERIES Page 23 The E5X Series offers ultimate versatility in power monitoring with a wide choice in mounting options, inputs, outputs, and communication protocols including BACnet, LON, and Modbus. The meters are compact in size allowing multiple meters to be mounted in the same panel, saving installation time and costs. Liquid & Chemical Leak Detection LD SERIES & SC SERIES Page 141-145, 149 Complete leak detection systems protect expensive electronics from costly water damage. Monitor a single location or large area with reliable sensing devices and controller systems. Remote Pressure Transducers PWR SERIES Page 171 The PWR Series remote wet media pressure transducers allow remote pressure sensing capability using existing plumbing runs. With no need to run plumbing lines all the way to the transducer, the installation time and cost is greatly reduced. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com 8 MULTI-FLOOR OFFICE WORKSPACE Provide ideal environmental conditions, while optimizing efficiency Occupancy Sensors MSX SERIES Page 209 Reduce energy consumption and control energy waste by lighting a room only when it's occupied. Humidity Sensors HW2 SERIES Page 125 High accuracy sensor provides an ideal working environment. A modern aesthetic and touchscreen display allow for optimal humidity control at zone level. Temperature Sensors TW2, TD SERIES Page 183 Monitor temperature at a zone level with high accuracy to provide an ideal environment. 9 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com BUILDING SAFETY & EFFICIENCY Monitor parking structures, maintain optimal building and duct pressure Gas Detection CO, NO2 SENSORS Pages 85 & 87 Easy parking garage monitoring with the GWN and GWNP modular platforms. Monitor CO and NO2 separately or combined. Differential Pressure or Air Velocity Sensor PX3 SERIES Page 157 Precisely measure differential air pressure or velocity with the flip of a switch using Bluetooth® technology. CO2 Sensors CW2 SERIES Page 73 Calling for fresh air only when CO2 levels are high saves energy. Make the CW2 Series part of your demand controlled ventilation strategy. SUB-TENANT & POWER USAGE MONITORING Accurately monitor and invoice energy consumption HVAC & PHYSICAL PLANT Detect leaks in sprinkler systems, measure chiller/boiler line pressure, and enable rooftop unit control via sensors Adjustable Current Switches H308 Page 241 Reliably detect belt loss, coupling shear, and mechanical failures. Sub-Tenant Metering ENERCEPT FLEX E20 SERIES Page 19 Maximum retrofit flexibility. Monitor loads from 50 to 5,000 A on the same rope style CT. Main Panel & Single-Circuit Power Metering E5X SERIES Page 23 The E5X Series offers ultimate versatility in power monitoring with a wide choice in mounting options, inputs, outputs, and communication protocols including BACnet, LON, and Modbus. The meters are compact in size, allowing multiple meters to be mounted in the same panel, saving installation time and costs. Motor Control Relays V100 SERIES Page 285 The Victory 100 Series 10A relays are pilot-duty relays in an easy-to-use nipple mount enclosure. Great for building control applications. Multi-Circuit Monitoring E3X SERIES Page 35 Provides comprehensive monitoring of panelboards and RPPs with revenue-grade accuracy for new construction projects. Flow Monitoring 380 SERIES Page 101 Metering of heated or chilled liquid, with a turbine flow meter and BTU transducer in one compact package. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com 10 RESIDENTIAL MULTITENANT SUB-TENANT METERING Monitor main circuits, individual circuits and BTUs for individual billing Energy Meters ENERCEPT FLEX E20 SERIES Page 19 Maximum retrofit flexibility. Monitor loads from 50 to 5000 A on the same rope style CT. Power & Energy Monitors E5X SERIES Page 23 DIN mounted power meter ideal for sub-metering individual loads where a local display is required. Energy Meters H8163 SERIES Page 27 Provide revenue grade energy consumption visibility to tenants and building management. 11 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com LIVING & SHARED SPACES Create comfortable, energyefficient environments BUILDING INFRASTRUCTURE Monitor sprinkler systems for leaks and efficiently maintain ideal air quality Occupancy Sensors MSX SENSORS Page 209 Reduce energy consumption and control energy waste by lighting a room only when it's occupied. Communicating Thermostats VIC-VT8650 SERIES Page 223 Maximize system adaptability in rooftop unit control with BACnet, LON or wireless communication protocol. CO2 Sensors CW2 SERIES Page 73 Calling for fresh air only when CO2 levels are high saves energy. Make the CW2 Series part of your demand controlled ventilation strategy. Liquid & Chemical Leak Detection LD SERIES & SC SERIES Page 141-145, 149 Complete leak detection systems protect expensive electronics from costly water damage. Monitor a single location or large area with reliable sensing devices and controller systems. Gas Detection CO, NO2 SENSORS Pages 85 & 87 Easy parking garage monitoring with the GWN and GWNP modular platforms. Monitor CO and NO2 separately or together. BTU Monitoring 380 SERIES Page 101 Metering of heated or chilled liquid, with a turbine flow meter and BTU transducer in one compact package. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com 12 SCHOOLS CLASSROOMS & COMMON AREAS Maintain a comfortable learning environment, while optimizing efficiency Occupancy Sensors MSX SERIES Page 209 Reduce energy consumption and control energy waste by lighting a room only when it's occupied. Humidity Sensors HW2 SERIES Page 125 High accuracy sensor provides an ideal learning environment. A modern aesthetic and touchscreen display allow for optimal humidity control at zone level. Temperature Sensors TW2, TD SERIES Page 183 Monitor temperature at zone level with high accuracy to provide an ideal environment. 13 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com BUILDING SAFETY & EFFICIENCY Monitor parking structures, maintain wood shop/metal shop pressure control, manage demand controlled ventilation POWER & ENERGY Quantify and qualify usage Gas Detection CO, NO2 SENSORS Pages 85 & 87 Easy parking garage monitoring with the GWN and GWNP modular platforms. Monitor CO and NO2 separately or combined. Differential Pressure or Air Velocity Sensor PX3 SERIES Page 157 Precisely measure differential air pressure or velocity with the flip of a switch using Bluetooth® technology. CO2 Sensors CW2 SERIES Page 73 Calling for fresh air only when CO2 levels are high saves energy. Make the CW2 Series part of your demandcontrolled ventilation strategy. Sub-Metering ENERCEPT FLEX E20 SERIES Page 19 Maximum retrofit flexibility. Monitor loads from 50 to 5,000 A on the same rope style CT. Multi-Circuit Monitoring E3X SERIES Page 35 Provides comprehensive monitoring of panelboards and RPPs with revenue-grade accuracy for new construction projects. Main Panel & Single-Circuit Power Metering E5X SERIES Page 23 The E5X Series offers ultimate versatility in power monitoring with a wide choice in mounting options, inputs, outputs, and communication protocols including BACnet, LON, and Modbus. The meters are compact in size allowing multiple meters to be mounted in the same panel, saving installation time and costs. HVAC & PHYSICAL PLANT Empower motor control, detect mechanical failure, meter heated or chilled liquids Communicating Thermostats VIC-VT8650 SERIES Page 223 Maximize system adaptability in rooftop unit control with BACnet,LON or wireless communication protocol. Adjustable Current Switches H308 Page 241 Reliably detect belt loss, coupling shear, and mechanical failures. Flow Monitoring 380 SERIES Page 101 Metering of heated or chilled liquid, with a turbine flow meter and BTU transducer in one compact package. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|www.veris.com 14 POWER MONITORING SINGLE-CIRCUIT Veris Industries leads the way with a complete line of innovative power monitoring solutions that save time and money. Veris power monitors are available with popular communication protocols that allow for labor-saving networked wiring, and standard pulse and analog outputs as well. Earn LEED® points and make Veris power monitors part of your energy conservation plan. MODEL DESCRIPTION E2x FLEX Enercept FLEX Compact Power and Energy Meters E2x System Calibrated Enercept System Calibrated Compact Power and Energy Meters E5x Enhanced Power and Energy Meters E5xxxA Enhanced Power and Energy Meter, Built-in Rope CT Integrator and Power Supply H8163 Sub-tenant Meter with Calibrated CTs See following pages for selection guides. PAGE 19 21 23 25 27 15 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com MAXIMUM FLEXIBILITY FOR RETROFIT APPLICATIONS Enercept FLEX® Power and Energy Meters APPLICATIONS » Retrofit metering for code compliance or energy efficiency goals » Easy deployment for many single circuit meters » Bi-directional energy monitoring for renewables FEATURES SIMPLE SETUP Rotary dials for configuring with the power off Re-assign phase or CT polarity through software ESSENTIAL PROTOCOL SUPPORT Modbus RTU and BACnet MS/TP support SYSTEM CALIBRATED SERIES One reference for all-in-one solutions with CTs and fuses prewired Calibrated 1% system accuracy Minimized commissioning time VERSATILE DESIGN Small, lightweight form factor Control power support for 90-480VAC 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 16 61 SINGLE-CIRCUIT ENERGY/POWER METERS GUIDE SERVICE TYPE VOLTAGE SINGLE-PHASE 120-240V PULSE H8163-xxxx-x-1 E5xB1/E5xCx MODBUS1 H8163-xxxx-x-1 and H8163-CB1 E23 E5xCx Output / Protocol BACNET MS/TP H8163-xxxx-x-1 and H8186-CB E23 E5xHx BACNET IP2 H8163-xxxx-x-1, H8186-CB and U013-0013 E23 and U013-0013 E5xHx and U013-0013 SINGLE-PHASE 240V H8163-xxxx-x-2 E5xB1/E5xCx H8163-xxxx-x-2 and H8163-CB E23 E5xCx H8163-xxxx-x-2 and H8186-CB E23 E5xHx H8163-xxxx-x-2, H8186-CB and U013-0013 E23 and U013-0013 E5xHx and U013-00133 3-PHASE WYE 120-480V 90-600V H8163-xxxx-x-3 E5xB1/E5xCx H8163-xxxx-x-3 and H8163-CB E23 E5xCx H8163-xxx and H8186-CB E23 E5xHx H8163-xxxx, H8186-CB and U013-0013 E23 and U013-0013 E5xHx and U013-0013 3-PHASE DELTA 120-480V E23 E23 (NO-NEUTRAL) 90-600V E50B1/E50Cx E5xCx E5xHx 1. All Veris Modbus products support Modbus RTU (serial) natively. For Modbus TCP (Ethernet), add the U013-0012 Modbus Gateway. 2. The U013-0013 is a BACnet router, which adds BACnet IP support to any product with BACnet MS/TP. E23 and U013-0013 E5xHx and U013-0013 Retrofit Enercept E23 Series Versatility E50/E51 Series Simplicity & Accessability H8163 Series LON E50Fx E50Fx E50Fx E50Fx N2 H8163-xxxx-x-1 and H8126-CB H8163-xxxx-x-2 and H8126-CB H8163-xxxx-x-3 and H8126-CB 17 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com OPTIMIZE ENERGY COSTS & CONSUMPTION WITH VISIBILITY OF POWER USE Power Monitoring Single-Circuit Ultimate Flexibility Enercept E2x FLEX Series Meters From form factor to function, the Enercept E2x was designed with the user in mind. The meter's small form factor enables installation in panels with limited space and does not require external mounting. Simplified setup and support for a wide range of CTs make the Enercept E2x a highly versatile solution. Ultimate Retrofit - Enercept E2x System Calibrated Series Meters The easiest meter to install with the simplest way to order, the system calibrated Enercept E2x provides higher accuracy without sacrificing flexibility. A single part number includes a pre-wired meter, CTs and fuses. Factory calibration achieves 1% overall accuracy for a wide range of applications. Ultimate Simplicity H8163 Series Meters Meet requirements & get quick access to the information needed for sub-tenant metering or monitoring energy consumption with this enclosed wall-mount meter that includes a customer accessible LCD display. They are simple to buy with calibrated CTs included, simple to install and use where customers and managers can safely read the information they need, simple to integrate with a range of communication protocol options. Ultimate Versatility E5x Series Meters Save costs while addressing a broad range of applications from sub-metering to full bi-directional monitoring of renewable energy installations with a meter that has comprehensive measurement capabilities. It can be panel, DIN rail, or wall mounted, and offers a wide choice of inputs, outputs, & communication protocols. Bi-directional models monitor alternative energy sources or loads with regenerative braking. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 18 81 Power Monitoring Single-Circuit | Enercept FLEX® E2x Compact Power & Energy Meters E2X FLEX SERIES Uni-directional, Bi-directional, Modbus, & BACnet IEC model shown High reliability ANSI C12.20 0.2% accuracy, IEC 62053-22 Class 0.2S 90 to 480 Vac Application versatility with fewer models to stock Wide range of service types Compatible with CTs from 5 to 5000 A Easy installation DIN rail or screw mount options (with included mounting bracket) Easy ordering & stocking Modbus and BACnet protocols along with uni-directional and bidirectional feature sets in one unit Protocol support Native Modbus and BACnet MS/TP support (no gateway) with serial rates up to 115.2 kbaud Enercept FLEX E2x Series power and energy meters provide a unique solution for measuring energy data. Designed with the user in mind, the E2x Series offers maximum application flexibility for retrofit applications. The Enercept FLEX E2x Series is compatible with split-core, solidcore and Veris E683x Series rope-style Rogowski current transducers (CTs) from 5 to 5000 A, often allowing installers to utilize existing CTs with the meter. Adding to its versatility, the Enercept FLEX E2x Series has a wide input range of 90 to 480 Vac, alleviating the need to keep multiple models in stock. The meter's small form factor enables installation in existing panels with limited space, and does not require external mounting or the expense of extra enclosures or conduit runs. Communicating models support auto detection of baud rate, parity, and protocol for Modbus® RTU and BACnet® MS/TP. APPLICATIONS · Energy monitoring (BAS) · Renewable energy · Energy management · Commercial sub-metering · Industrial monitoring · Cost allocation SPECIFICATIONS MEASUREMENT ACCURACY* Real Power & Energy, IEC 62053-22 Class 0.2S, ANSI C12.20, 0.2% 1/3 Volt Current Input Mode Real Power & Energy, IEC 62053-22 Class 0.5S, ANSI C12.20, 0.5% Rogowski Current Input Mode Reactive Power & Energy IEC 62053-24 Class 1, 1% INPUT VOLTAGE CHARACTERISTICS Measured AC Voltage Impedance Frequency Range Min. 90 VL-N (156 VL-L) for stated accuracy; UL max.: 480 VL-L (277 VL-N); CE max.: 300 VL-N 2.5 ML-N / 5 ML-L 45 to 65 Hz INPUT VOLTAGE CHARACTERISTICS Measurement Range 0 to 0.333 Vac (+20% over-range) Impedance 33 k CONTROL POWER AC Drawn from phase A-B line-to-line voltage input 4 VA max.: 90VL-N min. UL max.: 480 VL-L (277 VL-N) CE max.: 300VL-N Ride-through Time 50 ms at 120 Vac MECHANICAL CHARACTERISTICS Ingress Protection (IEC 60529) IP20 Plug Wire Size (I/O, Communications, CT) 24 to 16 AWG (0.2 to 1.5 mm2) Optional Bracket: Rail Mounted T35 (35 mm) DIN rail per EN 50022 Optional Bracket: Wall Mounted Two #10 or M5 screws, 2.953" (75 mm) center-to-center ENVIRONMENTAL CONDITIONS Operating Temperature -30 to 70 °C (-22 to 158 °F) Storage Temperature -40 to 85 °C (-40 to 185 °F) Humidity Range <95% RH (non-condensing) Altitude of Operation 3 km max. Pollution Degree 2 Mounting Location Not suitable for wet locations. For indoor use only. 19 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Monitoring Single-Circuit | Enercept FLEX E2x Series SPECIFICATIONS (CONT.) METERING CATEGORY UL CE Dielectric Withstand Conducted and Radiated Emissions Conducted and Radiated Immunity WARRANTY Limited Warranty AGENCY APPROVALS US and Canada Europe (CE) CAT III; for distribution systems up to 277 VL-N / 480 VacL-L CAT III; for distribution systems up to 300 VL-N Per UL 61010-1, EN 61010-1 FCC part 15 Class A, EN 61000-6-4, EN 61326-1 Class A (industrial) EN 61000-6-2, EN 61326-1 (industrial) 5 years UL 61010-1 EN 61010-1 TE S T ING ® B A C n e t · LABOR * The meters were tested compliant to the norms: · ANSI C12.20, Class 0.2, from 1% to 100% rated current · IEC 62053-22, Class 0.2S, from 1% to 100% rated current · IEC 62053-22, Class 0.5S for Rogowski coils, from 1% to 100% rated current · IEC 62053-24 Class 1, from 1% to 100% rated current ORDERING INFORMATION DIMENSIONAL DRAWING 5.998" (152.36 mm) 6.675" (169.54 mm) DIMENSIONS, MOUNTED Front View 1.836" (46.63 mm) 1.410" (35.81 mm) Side View 3.0" (75 mm) Bracket Hole Spacing · A TO R I E S E23Cx MEASUREMENT CAPABILITY - FULL DATA SET Bi-directional Energy Measurements · Power (3-phase Total and Per Phase): Real (kW) Reactive (kVAR), and Apparent (kVA) · Power Factor: 3-phase Average and Per Phase · Present Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) · Import and Export Totals of Present Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) · Peak Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) · Current (3-Phase Average and Per Phase) · Voltage: Line-Line and Line-Neutral (3-phase Average and Per Phase) · Frequency · ANSI C12.20 0.2% Accuracy, IEC 62053-22 Class 0.2S · Accumulated Net Energy: Real (kWh), Reactive (kVARh), and Apparent (kVAh) · Accumulated Real Energy by Phase (kWh) · Import and Export Accumulators of Real and Apparent Energy · Reactive Energy Accumulators by Quadrant (3-phase Total and Per Phase) · Demand Interval Configuration: Fixed or Rolling Block · Demand Interval Configuration: External Sync to Comms · OUTPUTS RS-485 Serial (Modbus RTU Protocol) · RS-485 Serial (BACnet MS/TP Protocol) · 6.7" (169.33 mm) 1.750" (44.45 mm) 2.1" (53.08 mm) 1.410" (35.81mm) 1.7" (43.58 mm) to Bracket 1.8" (46.28 mm) to DIN Rail ORDERING INFORMATION Data Set E 23 = Uni/Bi Dir (FDS) I/O C = RS-485 MB/BAC Example: E 23 C 6 System Types & Wires 5 = 1, 2, or 3ph (A-B-C-N) IEC International 6 = 1, 2, or 3ph (A-B-C-N) ANSI North & South America ACCESSORIES P. 69 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 20 02 Power Monitoring Single-Circuit | System Calibrated Enercept® Compact Power & Energy Meters SYSTEM CALIBRATED E2X SERIES Uni-directional, Bi-directional, Modbus & BACnet Pre-wired & Easy ordering & factory calibrated stocking Meter, CTs and fuse pack pre-wired and factory calibrated for timesaving installation and improved system-level accuracy ... meter + CTs + Fuse pack (ANSI models ONLY), meter + CTs (IEC models) Modbus and BACnet protocols along with uni-directional and bi-directional feature sets in one unit 90 to 480 Vac Application versatility with fewer models to stock Easy installation DIN rail or screw mount options (with included mounting bracket) System calibrated Enercept E2x Series power and energy meters provide a unique solution for measuring energy data. Designed with the user in mind, these meters offer maximum application flexibility for retrofit applications. These meters provide innovative three-phase networked (Modbus RTU and BACnet MS/TP) power transducers that calibrate measurement electronics, high accuracy industrial grade CTs and fusing protection in a single package. External mounting is eliminated, greatly reducing installation and configuration time and cost. Color coordination between voltage leads and CTs makes phase matching easy. Communicating models support auto detection of baud rate, parity and protocol for Modbus RTU and BACnet MS/TP. Up to 63 Enercept meters can be daisy-chained on a single RS-485 network. One part number Protocol support One part number simplifies ordering ... meter + CTs + fuse pack (ANSI models ONLY), meter + CTs (IEC models) Modbus RTU and BACnet MS/TP APPLICATIONS · Energy monitoring (BAS) · Renewable energy · Energy management · Commercial submetering · Industrial monitoring · Cost allocation SPECIFICATIONS MEASUREMENT ACCURACY1 Real Power & Energy, 1/3 Volt IEC 62053-21 Class 1S, ANSI C12.1, 1% Current Input Mode Real Power & Energy, IEC 62053-21 Class 1S, ANSI C12.1, 1% Rogowski Current Input Mode Reactive Power & Energy IEC 62053-24 Class 1, 1% System Accuracy ± 1% (split-core models). 1% on Rogowski models reading from 5 to 100% of rated current of the CTs. This is accomplished by matching the CTs with electronics and calibrating them as a system. INPUT VOLTAGE CHARACTERISTICS Measured AC Voltage Impedance Frequency Range Min. 90 VL-N (156 VL-L) for stated accuracy; UL max.: 480 VL-L (277 VL-N); CE max.: 300 VL-N 2.5 ML-N / 5 ML-L 45 to 65 Hz Measurement Input Range 0 to 0.333 Vac (+20% over-range) Impedance 33 k CONTROL POWER AC AC: Drawn from phase A-B line-to-line voltage input; 4 VA max.: 90 VL-N min.; UL max.: 480 VL-L (277 VL-N); CE max.: 300 VL-N Ride-through Time 50 ms at 120 Vac MECHANICAL CHARACTERISTICS Ingress Protection (IEC 60529) IP20 Plug Wire Size (I/O, Communications) 24 to 16 AWG (0.2 to 1.5 mm2) Optional Bracket: Rail Mounted T35 (35 mm) DIN rail per EN 50022 Optional Bracket: Wall Mounted Two #10 or M5 screws, 2.953" (75 mm) center-to-center CT RATINGS E23C5-xx, E23C6-xx 1000 Vac reinforced insulation rating E23C5-101, E23C6-101, E23C5-201, E23C6-201 600 Vac basic insulation rating, 300 Vac reinforced insulation rating E23C5-401, E23C6-401 1000 Vac basic insulation rating, 600 Vac reinforced insulation rating ENVIRONMENTAL CONDITIONS Operating Temp. 0 to 70 °C (32 to 158 °F) Storage Temp. (with CTs) -40 to 85 °C (-40 to 185 °F) Storage Temp. (with Rogowski -40 to 70 °C (-40 to 158 °F) Coils) 21 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Monitoring Single-Circuit | System Calibrated Enercept E2x Series · A TO R I E S E23Cx -xxx SPECIFICATIONS (CONT.) Humidity Range Altitude of Operation Pollution Degree Mounting Location METERING CATEGORY UL CE Dielectric Withstand Conducted and Radiated Emissions Conducted and Radiated Immunity AGENCY APPROVALS US and Canada Europe (CE) WARRANTY Limited Warranty <95% RH (non-condensing) 3 km max. 2 Not suitable for wet locations. For indoor use only. CAT III; for distribution systems up to 277 VL-N / 480 VacL-L CAT III; for distribution systems up to 300 VL-N Per UL 61010-1, EN 61010-1 FCC part 15 Class A, EN 61000-6-4, EN 61326-1 Class A (industrial) EN 61000-6-2, EN 61326-1 (industrial) UL 61010-1 IEC/EN 61010-1 5 years TE S T ING ® B A C n e t · LABOR 1. The meters were tested compliant to the norms: · ANSI C12.1, Class 1 from 1% to 100% rated current · IEC 62053-21, Class 1 from 1% to 100% rated current · IEC 62053-24 Class 1, from 1% to 100% rated current ORDERING INFORMATION MEASUREMENT CAPABILITY - FULL DATA SET Bi-directional Energy Measurements · Power (3-phase Total and Per Phase): Real (kW) Reactive (kVAR) and Apparent (kVA) · Power Factor: 3-Phase Average and Per Phase · Present Power Demand: Real (kW), Reactive (kVAR) and Apparent (kVA) · Import and Export Totals of Present Power Demand: Real (kW), Reactive (kVAR) and Apparent (kVA) · Peak Power Demand: Real (kW), Reactive (kVAR) and Apparent (kVA) · Current (3-Phase Average and Per Phase) · Voltage: Line-Line and Line-Neutral (3-phase Average and Per Phase) Frequency · Accumulated Net Energy: Real (kWh), Reactive (kVARh) and Apparent (kVAh) · Accumulated Real Energy by Phase (kWh) · Import and Export Accumulators of Real and Apparent Energy · Reactive Energy Accumulators by Quadrant (3-phase Total and Per Phase) · Demand Interval Configuration: Fixed or Rolling Block · Demand Interval Configuration: External Sync to Comms · OUTPUTS RS-485 Serial (Modbus RTU Protocol) · RS-485 Serial (BACnet MS/TP Protocol) · DIMENSIONAL DRAWING 3 2 654 901 37 28 ADDRESS Settings Overridden Via Comms ENERCEPTTM SYSTEM POWER METER BACnet/Modbus PHASE STATUS L1 L2 L3 Green = Normal Operation See Manual for Other Indicator States 1.8" 47mm 1.4" 36mm Status 6.0" 152mm 1.7" 44mm 901 8 7 654 Rx Tx 100A, 200A & 400 A CTS Dimensional Drawings D B C A E 100 Amp A = 1.2" (30 mm) B = 0.8" (20 mm) C = 0.7" (18 mm) D = 1.6" (41 mm) E = 2.1" (53 mm) 400 Amp D A A = 1.2" (30 mm) B C E B = 1.5" (38 mm) C = 1.3" (33 mm) D = 3.9" (99 mm) E = 3.3" (84 mm) 12" & 18" ROGOWSKI CT Dimensional Drawing D A 200 Amp A = 1.5" (38 mm) B C E B = 1.25" (32 mm) C = 1.25" (32 mm) D = 2.5" (64 mm) E = 2.8" (71 mm) 1.05 in. (26.50 mm) 2.84 in. (72 mm) 8 ft. (2.45 m) 7.7 ft. (2.35 m) 3.76 in. (96 mm) 5.76 in. (146 mm) (FOR REFERENCE ONLY) 12 in. (300 mm) 18 in. (460 mm) 0.33 in. (8.3 mm) ORDERING INFORMATION System Types Data Set I/O & Wires E - CT Size 23 = Uni/Bi Dir (FDS) C = Modbus RTU & BACnet MS/TP Example: E 23 C 6 - 201 5 = IEC international wire code 6 = ANSI North & South America wire code 101 = 3 ph, 3 wire, 100 A, split-core micro 201 = 3 ph, 3 wire, 200 A, split-core mini 401 = 3 ph, 3 wire, 400 A, split-core small 12 = 3 ph, 3 wire, 12" Rogowski 18 = 3 ph, 3 wire, 18" Rogowski ACCESSORIES P. 69 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 22 22 Power Monitoring Single-Circuit | Enhanced Power and Energy Meters E5X SERIES Versatile Energy Monitoring Solution Revenue grade measurements Meets ANSI C12.20 Class 0.2 standards Multiple applications Real energy output and phase loss alarm output on E50Bx and E5xCx models...one device serves multiple applications E50/E51 The E5x Series DIN Rail Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power monitoring applications. The E5x can be installed on standard DIN rail or surface mounted as needed. The Modbus, LON, and BACnet output models offer added flexibility for system integration. The data logging capability (E5xC3 and E5xx5) protects data in the event of a communications or power failure elsewhere in the system. Combinations of serial communication, pulse output, and phase alarms are provided to suit a wide variety of applications. Additional pulse inputs on E5xHx and E50Fx provide an easy way to incorporate simple flow sensors to track gas, water, steam, or other energy forms using a BACnet or LON system. The E51 models add a bi-directional monitoring feature designed expressly for renewable energy applications, allowing measurement of power imported from the utility grid as well as power exported from the renewable energy source (e.g. solar panels). In this way, a facility administrator can track all energy data, ensuring accuracy in billing and crediting. They are also useful for monitoring loads that use regenerative braking. SPECIFICATIONS INPUTS Control Power, AC Control Power, DC Voltage Input CURRENT INPUT Scaling Input Range Pulse Inputs E5xHx & E50Fx only ACCURACY Real Power & Energy OUTPUTS E50B1 & E5xCx 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 VL-L (347 VL-N); CE Maximum: 300 VL-N 3W max.; UL and CE: 125 to 300 Vdc (external DC current limiting required) UL: 90 VL-N to 600 VL-L; CE: 90 VL-N to 300 VL-N 5 A to 32,000 A 0 to 0.333 V or 0 to 1 V (selectable) CTs must be rated for use with Class 1 voltage inputs Contact inputs to pulse accumulators (one set with E5xH2 and E50F2; two sets with E5xH5 and E51F5)* 0.2% (ANSI C12.20, IEC 62053-22 Class 0.2S) Real Energy Pulse: N.O. static**; Alarm contacts: N.C. static** High reliability ANSI C12.20 0.2% accuracy, IEC 62053-22 Class 0.2S on E5xxx Data logging Ensures long term data retrieval and safeguards during power failures (E5xC3 and E5xx5) Easy installation DIN rail or screw mounting options Wide CT compatibility Compatible with CTs from 5 A to 32000 A APPLICATIONS · Energy monitoring in building automation systems · Renewable energy · Energy management · Commercial sub-metering · Industrial monitoring · Cost allocation E50Bx Reactive energy pulse 30 Vac** E5xCx RS-485 2-wire Modbus RTU (1200 baud to 38.4 kbaud) E5xHx RS-485 2-wire BACnet MS/TP (9600 baud to 115.2 kbaud) E50Fx 2-wire LON FT MECHANICAL Mounting DIN Rail or 3-point screw mount ENVIRONMENTAL Altitude of Operation 3000 m Operating Temp Range -30 to 70 °C (-22 to 158 °F) Storage Temp Range -40 to 85 °C (-40 to 185 °F) Humidity Range <95% RH non-condensing Mounting Location Not suitable for wet locations. For indoor use only. WARRANTY Limited Warranty 5 years AGENCY APPROVALS Agency Approvals UL 508 (Open Type Device), IEC/EN 61010-1, California CSI Solar, ANSI C12.20, Cat III, Pollution Degree 2 ® B A C n e t · · A TO R I E S TE S T ING E51Cx only LABOR E5xH2 only *10 k Vac/dc to 4 to 10 Vdc. **30 Vac/dc, 100 mA max. (AC: 50/60Hz). 23 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Monitoring Single-Circuit | E5x Series E50B1 E50C2 E50C3 E50F2 E50F5 E50H2 E50H5 E51C2 E51C3 E51H2 E51H5 ORDERING INFORMATION MEASUREMENT CAPABILITY - FULL DATA SET Bi-directional Energy Measurements ···· Power (3-phase total and per phase): Real (kW) Reactive (kVAR), and Apparent (kVA) · · · · · · · · · · · Power Factor: 3-phase average & per phase ··········· Present Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) ··········· Import and Export totals of Present Power Demand: Real (kW), Reactive (kVAR), & Apparent (kVA) ···· Peak Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) ··········· Current (3-phase average and per phase) · · · · · · · · · · · Voltage: Line-Line and Line-Neutral (3-phase average and per phase) ··········· Frequency ··········· ANSI C12.20 0.2% accuracy, IEC 62053-22 Class 0.2S · · · · · · · · · · · Accumulated Net Energy: Real (kWh), Reactive (kVARh), and Apparent (kVAh) ··········· Accumulated Real Energy by phase (kWh) ··········· Import and Export Accumulators of Real and Apparent Energy ···· Reactive Energy Accumulators by Quadrant (3-phase total & per phase) ···· Demand Interval Configuration: Fixed or Rolling Block ··········· Demand Interval Configuration: External Sync to Comms ·········· DATA LOGGING Data Logging: 10 16-Bit Configurable (can include Date/Time) Data Buffers · · Data Logging: 3 Timestamped 32-Bit Configurable Data Buffers · · · Store up to 60 days of readings at 15-minute intervals · · · · · Alarm Output (N.C.) OUTPUTS ···· · ··· 1 Pulse Output (N.O.) ·· ·· 2 Pulse Outputs (N.O.) RS-485 Serial (Modbus RTU Protocol) · ·· ·· RS-485 Serial (BACnet MS/TP Protocol) ·· ·· LON FT Serial (LonTalk Protocol) ·· INPUTS 2 Pulse Contact Accumulator Inputs · · · 1 Pulse Contact Accumulator Input · · · DIMENSIONAL DRAWING 2.3" (59mm) 4.2" (107mm) 1.8" (45mm) 1.9" (48mm) 1.5" (39mm) 3.6" (91mm) DIN MOUNT CONFIGURATION Mounting Diagram 4.2 " (107 mm) 3.6 " (91 mm) 0.2 " (4 mm) SCREW MOUNT CONFIGURATION Mounting Diagram 2.4 " (61 mm) 1.2 " + (31 mm) + 0.3 " (8 mm) 3.9" (99 mm) 4.3 " (109 mm) + 0.4 " (10 mm) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 69 24 42 Power Monitoring Single-Circuit | Enhanced Power and Energy Meters, Built-in CT Integrator and Power Supply E5XXXA SERIES Cost-Saving, Versatile Monitoring Solution with Associated E683x Rope Style CTs (Sold Separately) Faster installation Integrator and power supply for the CTs are built into the meter... fewer devices to purchase and faster installation 0.5% accuracy ANSI C12.20 0.5% accuracy, IEC 62053-22 Class 0.5S on all E5xxxA...great for cost allocation Rope CTs Versatile rope CTs allow convenient installation in tight spaces Easy installation DIN rail or screw mounting options E50xxxA/E51xxxA E683x Series Rope CT (sold separately) The E5xxxA Series DIN Rail Meter combines exceptional metering performance with a built-in integrator and power supply to deliver a cost-effective, easily installed solution for power monitoring applications. Multiple communication protocol options offer added flexibility for easy system integration. E5xxxA devices work exclusively with Veris E683x Series rope CTs for fast connection. The rope style CTs allow convenient installation in tight spaces. The data logging capability (E5xC3A and E5xx5A) protects data in the event of a power or communications failure elsewhere in the system. Different devices in the series offer serial communication, pulse output, and phase alarms to suit a wide variety of applications. 400 to 5000A Designed to work exclusively with E683x Series rope CTs which offer 1% accuracy from 50 to 5000 A... monitor a wide range of loads with breakers from 400 to 5000 A Multiple applications Real energy output and phase loss alarm output on E50BxA and E5xCxA models...one device serves multiple applications APPLICATIONS · Energy monitoring in building automation systems · Renewable energy · Energy management · Commercial sub-metering · Industrial monitoring · Cost allocation SPECIFICATIONS ACCURACY Real Power & Energy E5xxxA INPUTS Control Power, AC Control Power, DC Voltage Input Current Input Scaling Input Range Pulse Inputs (E5xHxA & E50FxA only) OUTPUTS All Models (except E5xHxA & E50FxA) E50BxA E5xCxA 0.5% (ANSI C12.20, IEC 62053-22 Class 0.5S) 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 VL-L (347 VL-N); CE Maximum: 300 VL-N 3 W max.; UL and CE: 125 to 300 Vdc (external DC current limiting required) UL: 90 VL-N to 600 VL-L; CE: 90 VL-N to 300 VL-N 50 to 5000 A E683x Series rope style CTs only (CTs must be rated for connection to Class 1 voltage inputs) Contact inputs to pulse accumulators (one set with E5xH2A & E50F2A; two sets with E5xH5A & E51F5A)* Real Energy Pulse: N.O. static**; Alarm contacts: N.C. static** Reactive energy pulse** RS-485 2-wire Modbus RTU (1200 baud to 38.4 kbaud) E5xHxA RS-485 2-wire BACnet MS/TP (9600 baud to 115.2 kbaud) E50FxA 2-wire LON FT MECHANICAL Mounting DIN rail or 3-point screw mount ENVIRONMENTAL Operating Temp Range -30 to 70 °C (-22 to 158 °F) Storage Temp Range -40 to 85 °C (-40 to 185 °F) Humidity Range <95% RH non-condensing Mounting Location Not suitable for wet locations. For indoor use only. WARRANTY Limited Warranty 5 years AGENCY APPROVALS Agency Approvals UL 508, IEC/EN 61010-1, California CSI Solar, ANSI C12.20 E51CxA only *10 k Vac/dc to 4 to 10 Vdc. **30 Vac/dc, 100 mA max. 25 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Monitoring Single-Circuit | E5xxxA Series ORDERING INFORMATION DIMENSIONAL DRAWING E50B1A E50C2A E50C3A E50F2A E50F5A E50H2A E50H5A E51C2A E51C3A E51H2A E51H5A MEASUREMENT CAPABILITY - FULL DATA SET Bi-directional Energy Measurements ···· Power (3-phase total and per phase): Real (kW)Reactive (kVAR), & Apparent (kVA) · · · · · · · · · · · Power Factor: 3-phase average & per phase ··········· Present Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) ··········· Import & Export totals of Present Power Demand: Real (kW), Reactive (kVAR), & Apparent (kVA) ···· Peak Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA) ··········· Current (3-phase average and per phase) · · · · · · · · · · · Voltage: Line-Line and Line-Neutral (3-phase average and per phase) ··········· Frequency ··········· ANSI C12.20 0.5% accuracy, IEC 62053-22 Class 0.5S · · · · · · · · · · · Accumulated Net Energy: Real (kWh), Reactive (kVARh), and Apparent (kVAh) ··········· Accumulated Real Energy by phase (kWh) ··········· Import and Export Accumulators of Real and Apparent Energy ···· Reactive Energy Accumulators by Quadrant (3-phase total and per phase) ···· Demand Interval Configuration: Fixed or Rolling Block ··········· Demand Interval Configuration: External Sync to Comms ··········· DATA LOGGING Data Logging: 10 16-Bit Configurable (can include Date/Time) Data Buffers · · Data Logging: 3 Timestamped 32-Bit Configurable Data Buffers · · · Store up to 60 days of readings at 15-minute intervals · · · · · OUTPUTS Alarm Output (N.C.) ···· · ··· 1 Pulse Output (N.O.) ·· ·· 2 Pulse Outputs (N.O.) · RS-485 Serial (Modbus RTU Protocol) ·· ·· RS-485 Serial (BACnet MS/TP Protocol) ·· ·· LON FT Serial (LonTalk Protocol) ·· INPUTS 2 Pulse Contact Accumulator Inputs · · · 1 Pulse Contact Accumulator Input · · · REQUIRED CTS MODEL E683C502 E683D502 E683G502 E683J502 E683L502 DESCRIPTION Rogowski CT, 250 mm (9"), 600 V, 5 kA Rogowski CT, 300 mm (12"), 600 V, 5 kA Rogowski CT, 460 mm (18"), 600 V, 5 kA Rogowski CT, 600 mm (24"), 600 V, 5 kA Rogowski CT, 900 mm (35"), 600 V, 5 kA 2.3" (59mm) 4.2" (107mm) 1.8" (45mm) 1.9" (48mm) 1.5" (39mm) 3.6" (91mm) DIN MOUNT CONFIGURATION Mounting Diagram 4.2 " (107 mm) 3.6 " (91 mm) 0.2 " (4 mm) SCREW MOUNT CONFIGURATION Mounting Diagram 2.4 " (61 mm) 1.2 " + (31 mm) + 0.3 " (8 mm) 3.9" (99 mm) 4.3 " (109 mm) + 0.4 " (10 mm) ACCESSORIES P. 69 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 26 62 Power Monitoring Single-Circuit | Energy Meters H8163 SERIES Sub-tenant Meter with Calibrated CTs for Superior System Accuracy Revenue grade measurements Meets ANSI C12.20 Class 0.2 standards Equipment protection Phase-loss alarm (H8163) LCD display Easy connection High resolution backlit LCD display provides clear readings at a distance...reduces the risk of data misinterpretation. Back-lighting can be disabled if desired. H8163 provides a pulse output from 1/10 to 1 pulse per kWh for easy connection to existing control or data acquisition systems H8163 The H8163 Series Energy Meters are easy to install and provide exceptional system accuracy, making them ideal for all sub-metering applications. Each meter is factory-matched with one to three split-core CTs. The meter/CT pairs are system-calibrated to provide excellent total system accuracies of 1% from 2% to 100% of the amperage rating of the CTs (e.g., 2 to 100 A with 100 A CTs).Matching serial numbers assure that the meter and CT were calibrated together (matching does not apply if using 100 A CTs). The H8163 is easy to install. The split-core CTs virtually eliminate the need to remove electrical conductors, reducing installation time. The meter is also capable of detecting and correcting phase reversal, eliminating the need for concern about CT load orientation. The convenient color coding of the CTs and voltage leads make correct connection simple. SPECIFICATIONS INPUTS (VOLTAGE) H8150 H8163 ACCURACY System Accuracy Sample Rate OUTPUTS LCD Display All Models H8163 ONLY Pulse Output Pulse Rate Pulse Width Phase Loss Alarm 90 to 132 Vac line-to-neutral 90 to 300 Vac line-to-neutral ±1% of reading from 2% to 100% of the rated current of the CTs, accomplished by matching the CTs with electronics and calibrating them as a system 1280 Hz 1.2" x 3.8" (31 mm x 97 mm) viewing area, 160 segments, backlit with LCD Normally open, Opto-FET, 100 mA@24 Vac/dc 0.101, 0.252, 0.50, or 1.00 kWh per pulse 200 msec closed N.O. (opens on alarm), Opto-FET, 100 mA @ 24 Vac/dc; fixed threshold 25% below Reduce installation costs With the optional communications board (H8163-CB), the H8163 can easily be added to a Modbus, BACnet or N2 control system network to report multiple variables including kW, kWh, kVAR, PF, amps and volts, providing crucial power information at a reduced installation cost APPLICATIONS · Commercial tenant sub-metering · Performance contracting · Allocating costs · Real-time power monitoring via local display or through control/data acquisition systems ENVIRONMENTAL Protection Class Altitude of Operation Operating Temp Range Storage Temp Range Humidity Range WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals NEMA 1 2000 m 0 to 50 °C (32 to 122 °F) -40 to 70 °C (-40 to 158 °F) 0 to 95% non-condensing; indoor use only 5 years UL61010-1, Cat. III, Pollution Degree 2 Approved for California CSI Solar applications (check the CSI website for model numbers). 1. Not supported at >1600 A. 2. Not supported at >2400 A. Note: Meter and CTs serial numbers must match, except for 100A CTs. Neutral voltage connection is required. 27 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 208/120 Vac, 4-WIRE, 3Ø, 200 A SERVICE Wiring Diagram H8163-0200-1-3 Power Monitoring Single-Circuit | H8163 Series 240 Vac, 3-WIRE, SINGLE PHASE, 100 A SERVICE Wiring Diagram H8163-0100-0-2 Hawkeye® 608 Hawkeye® 608 120 Vac, 2-WIRE, SINGLE PHASE, 100 A SERVICE Wiring Diagram H8163-0100-0-1 DIMENSIONAL DRAWING 7.6" (193 mm) 3" (77 mm) 8.3" (211mm) DATA OUTPUTS kWh, Consumption kW, Real power kVAR, Reactive power kVA, Apparent power Power factor Voltage, line to line Voltage, line to neutral Amps, Average current kW, Real Power ØA kW, Real Power ØB kW, Real Power ØC Power factor ØA Power factor ØB Power factor ØC Voltage, ØA to ØB Voltage, ØB to ØC Voltage, ØA to ØC Voltage, ØA to Neutral Voltage, ØB to Neutral Voltage, ØC to Neutral Amps, Current ØA Amps, Current ØB Amps, Current ØC Deman d kW and kVAR * Peak Demand * Time Stamp * * With H8163-CB Communications Board installed ORDERING INFORMATION 120 Vac to 480 Vac (nom.) with Pulse and Phase Loss Outputs AMPS 1 CT 2 CTs 3 CTs VOLTAGE OUTPUT 100 Micro H8163-0100-0-1 H8163-0100-0-2 H8163-0100-0-3 200 Mini H8163-0200-1-2 H8163-0200-1-3 300 Small H8163-0300-2-2 H8163-0300-2-3 400 Med 800 Med H8163-0400-3-3 H8163-0800-3-3 120 to 480 Vac Pulse & Phase Loss 800 Lg H8163-0800-4-3 1600 Lg H8163-01600-4-3 2400 Lg H8163-2400-4-3 14.8" (375 mm) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 69 28 8 2 POWER MONITORING MULTI-CIRCUIT Veris leads the way with a complete line of innovative power monitoring solutions that save time and money. Veris power monitors are available with popular communication protocols that allow for labor-saving networked wiring, and standard pulse and analog outputs as well. Earn LEED® points and make Veris power monitors part of your energy conservation plan. MODEL E34 E30, E31 DESCRIPTION Multi-circuit Meter Panelboard Monitoring System See following pages for selection guides. PAGE 33 35 29 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com MINIMIZE COST AND SPACE PER METER E34x Series Multi-Circuit Meter APPLICATIONS » Building and tenant sub-metering » HVAC and lighting equipment management » Cost allocation and peak load reduction FEATURES AFFORDABLE METERING POINT Add many metering points with low equipment and installation costs COMMON CTs, 1/3V OUTPUTS Eliminates need for shorting blocks and allows long CT lead extensions without compromising accuracy REVENUE GRADE MEASUREMENT ANSI and IEC Class 0.5% accuracy, ideal for tenant billing ADVANCED ALARMING Extensive alarming capabilities provide warning of critical load levels and dropouts CONFIGURE THE METERS YOU WANT User-configurable to any combination of 1, 2, or 3-phase meters 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 30 MULTI-CIRCUIT ENERGY/ POWER METERS GUIDE NEW PANELBOARDS 90 TO 300V LINE-TO-NEUTRAL SERVICE VOLTAGE, WITH LOADS UP TO 120A PER BRANCH MAX. # OF BRANCHES: 3/4" CT spacing 1" CT spacing 18 mm CT spacing 24 E30x224 36 E30x236 42 E30x042 E30x142 E30x242 48 E30x248 72 E30x272 84 E30x084 E30x184 E30x284 For BACnet IP or MS/TP on A, B, or C models, add the E8951 Modbus-to-BACnet converter (see Network Integration section for more information). Four levels of functionality available (x = A, B, C or E): A = Power/Energy for Branches & Mains B = Power/Energy for Mains, Current only for Branches C = Current only for Branches & Mains E = Power/Energy for Branches & Mains; integrated Ethernet with Modbus TCP, BACnet and SNMP PANELBOARD RETROFITS 90 TO 300V LINE-TO-NEUTRAL SERVICE VOLTAGE, WITH LOADS UP TO 240A PER BRANCH MAX. # OF BRANCHES: With 50A Branch CTs & 4' round ribbon cables Order Branch CTs & ribbon cables spearately 42 E31x42 E31x002 84 E31x84 E31x004 For BACnet IP or MS/TP on A, B, or C models, add the E8951 Modbus-to-BACnet converter (see Network Integration section for more information). Four levels of functionality available (x = A, B, C or E): A = Power/Energy for Branches & Mains B = Power/Energy for Mains, Current only for Branches C = Current only for Branches & Mains E = Power/Energy for Branches & Mains; integrated Ethernet MULTIPLE 3-PHASE LOADS 90 TO 300V LINE-TO-NEUTRAL SERVICE VOLTAGE, SUPPORTS CTS WITH 0.333V SECONDARY `A' - MODBUS RTU ONLY E34A04 E34A08 E34A14 E34A28 `E' - INTEGRATED ETHERNET E34E04 E34E08 E34E14 E34E28 3-PHASE WITHOUT NETURAL 4 8 14 28 NUMBER OF METERS 3-PHASE WITH NEUTRAL 2-PHASE 3 6 6 12 10 21 21 42 For BACnet IP or MS/TP on `A' models, add the E8951 Modbus-to-BACnet converter (see Network Integration section for more information). 1-PHASE 12 24 42 84 Branch Circuit Power Monitoring for New Panels E30, E30E Branch Circuit Power Monitoring for existing Panel Retrofits E31 Power Monitoring up to 28 3-Phase Meters E34 31 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com FLEXIBLE POWER MONITORING NEW PANELBOARD INSTALLATIONS E30 SERIES, page 35 Monitor up to 84 branch circuits, two 3-phase mains, and two neutrals in one compact meter. Designed to be integrated into any brand of panelboard, the E30 provides the data you need to monitor multiple PDUs, RPPs, key areas of buildings, or customer spaces. RETROFIT PANELBOARD INSTALLATIONS E31 SERIES, page 35 Monitor up to 84 branch circuits, two 3-phase mains, and two neutrals in one flexible meter. Designed to be field installed into existing panels, the E31 offers a main board and two or four adapter boards that can be integrated into the existing panel or remote mounted in a separate enclosure. Varying the ribbon cable and CT lead length gives you the ultimate flexibility to install metering in tight spaces and/or critical power panels. MULTI-CIRCUIT METER E34 SERIES, page 33 Add many 1-phase, 2-phase or 3-phase metering points with a single product. Saves on both equipment and installation costs as compared to individual meters. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 32 23 Power Monitoring Multi-Circuit | Multi-Circuit Meter E34X SERIES Add Up to 28 3-Phase Meters by Installing One Device E34A E34E Affordable Revenue grade metering points measurements Add many metering points with lower equipment and installation cost than traditional alternatives. Common CTs, 1/3V outputs ANSI & IEC Class 0.5% provides the accuracy needed for tenant billing applications. Configure the meters you want Eliminates need for shorting blocks and allows long CT lead extensions without compromising accuracy. Choose from a range of CT styles & sizes. Choose 4, 8, 14 or 28 3-phase meters. User-configurable to any combination of 1-, 2-, 3-phase meters. Reconfigure channels as needed to monitor neutral current. The E34x Series Multi-Circuit Meters make it easy to add many revenue grade metering points without having to purchase, mount, wire and commission individual energy meters. Simply add a single device with common voltage inputs and communication interface that can measure the current, voltage, power and energy consumption of up to (14) 3-phase circuits with a single board or up to (28) 3-phase circuits with a 2-board configuration. Save on the cost of both equipment and installation. Modbus RTU is standard on all models. The E34E offers a serial connection with a choice of Modbus RTU or BACnet MS/TP, as well as an Ethernet connection with Modbus TCP, BACnet IP and SNMP. To aid in commissioning, a configuration software tool, an Ethernet discovery tool (for the E34E) and a Commissioning Guide are available at no cost at veris.com/modbus. SPECIFICATIONS VOLTAGE INPUTS Measurement Voltage 90 to 300 Vac line-to-neutral, 50/60 Hz Control Power E34A: 90 to 277 Vac line-to-neutral, 50/60 Hz, 8 VA E34E: 100 to 277 Vac line-to-neutral, 50/60 Hz, 15 VA ACCURACY Power/Energy IEC 62053-21 Class 0.5, ANSI C12.20 class 0.5 Voltage ±0.5% of reading 90 to 277 V line-to-neutral Current ±0.5% of reading from 2% to 100% of full-scale OPERATION Sampling Frequency 2560 Hz Update Rate 2 seconds (both panels) Overload Capability 22 kAIC E34A SERIAL COMMUNICATION Physical Interface DIP switch-selectable 2-wire or 4-wire, RS-485 Protocols Supported Modbus RTU Address DIP switch-selectable address 1 to 247 (in pairs of 2)* Baud Rate DIP switch-selectable 9600, 19200, 38400 Parity DIP switch-selectable NONE, ODD, EVEN APPLICATIONS · Commercial and residential sub-tenant billing · Load-based cost allocation · Load balancing · Demand/response · Overload protection · Energy management E34E SERIAL COMMUNICATION Physical Interface 2-wire RS-485 Protocols Supported Modbus RTU or BACnet MSTP Address Range 1 to 247 for Modbus RTU; 0-127 for BACnet MS/TP Baud Rate 9600, 19200, 38400 Parity Modbus RTU: NONE, ODD, EVEN BACnet MS/TP: NONE (fixed) E34E ETHERNET COMMUNICATION Physical Interface RJ45 connector with 10/100 Mbit Ethernet Protocols Supported Modbus TCP, BACnet IP, SNMP V2c TERMINAL BLOCK TORQUE Removable Connectors 4.4 to 5.3 in-lb (0.5 to 0.6 N-m) OPERATING CONDITIONS Operating Temp. Range 0 to 60 °C (32 to 140 °F) (<95% RH non-condensing)* Storage Temp. Range -40 to 70 °C (-40 to 158 °F) Altitude of Operation 3000 m Mounting Location Indoor use, dry location WARRANTY Limited Warranty 5 years COMPLIANCE INFORMATION Agency Approvals UL508, IEC/EN61010-1 Installation Category Cat III, pollution degree 2 ® B A C n e t · · A TO R I E S TE S T ING LABOR (E34E only) 33 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Monitoring Multi-Circuit | E34x Series MEASUREMENTS Real Time Measurements Demand Measurements Historic Maximums Accumulated Energy Energy Snapshots MODBUS ALARMS Alarms Current: multi-phase average and per phase Current phase angle per branch Real power (kW): multi-phase total and per phase Apparent power (kVA): multi-phase total and per phase Power factor: multi-phase average and per phase Current present demand: multi-phase average and per phase Real power (kW) present demand: multi-phase average and per phase Maximum instantaneous current: multi-phase average and per phase Maximum current demand: multi-phase average and per phase Maximum real power demand: multi-phase total and per phase Energy (kWh): multi-phase total and per phase Energy (kWh): multi-phase total and per phase Voltage over/under Branch current over/under Mains current over/under E34A BASE BOARD Dimensional Drawing 8.3" (211 mm) 7.9" (200 mm) 3.9" (100 mm) Ø = 0.2" (5 mm) E34E MAIN UNIT Dimensional Drawing 7.3" (184 mm) 8.9" (226 mm) 5.8" (146 mm) 4.8" (122 mm) 1.75" (45 mm) 12.1" (307 mm) NUMBER OF METERS SUPPORTED E34A MODBUS RTU ONLY E34A04 E34A08 E34A14 E34A28 E34E INTEGRATED ETHERNET E34E04 E34E08 E34E14 E34E28 NUMBER OF METERS 3-PHASE 2-PHASE 1-PHASE 4 6 12 8 12 24 14 21 42 28 42 84 28-METER CT ADAPTER ASSEMBLY Dimensional Drawing 2.8" (71 mm) 8.9" (225 mm) 10.0" (253 mm) 8.2" (210 mm) 2x: 5.9" (150 mm) 12.8" (325 mm) 13.9" (353 mm) 9.50" (241 mm) 0.56" (14.3 mm) 1.60" (40.5 mm) 5.53" (140.5 mm) 6.56" (167 mm) 7.13" (181 mm) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 69 34 43 Power Monitoring Multi-Circuit | Panelboard Monitoring System E30 & E31 SERIES Monitor Entire Panelboards with One Device Revenue grade ANSI and IEC Class 1 metering system accuracy including branch CTs Measure THD Retrofit or new New construction and retrofit applications with solid-and split-core CT models Up to 92 channels E30A/E30B/E30C E31A/E31B/E31C E30E/E31E Integrated Modbus RTU and TCP, BACnet MS/TP and IP, SNMP The E30 and E31 Panelboard Monitoring Systems provide a costeffective solution for high density monitoring in critical applications. A single meter can monitor up to 84 circuits and two branches (eight circuits). Each meter's circuits can be assigned to logical meters representing single, dual or three phase circuits. Tailored for high density breaker panels, the E30 comes with 100A solid-core current transformer (CT) strips, with spacing that matches typical breaker spacing. This allows for the alignment of the metering instruments and reduces the chance of miswiring the CTs when all circuits have the same rating, such as in a data center power distribution unit (PDU). Adaptable to a large variety of loads, the E31 supports different split core CTs for larger windows and ratings between 50A, 100A and 200A. Each meter is available in four variants: Models A, B, C and E. Identify load inefficiencies and avoid early wear and tear Monitor up to 92 circuits per unit providing unlimited possibilities for monitoring 50 mA to 100 A Versatility Widest dynamic range in the industry, 50 mA to 100 A monitoring Flexible installation with 3/4", 1" or 18 mm spaced solid-core branch CT strips Site adapted metering Choose 4, 8, 14 or 28 3-phase meters. Configurable to any combination of 1-, 2-, 3-phase meters. Channels can be reassigned as needed. APPLICATIONS · Data center PDU · High density applications · Critical buildings · Load-based cost allocation · Load management · Load balancing · Energy management Models B and C are intended for simple current monitoring (Model C) and power factor and energy monitoring (Model B). Models A and E measure all of the Model B and C data points as well as power and total harmonic distortion (THD). Model E is Ethernet enabled. SPECIFICATIONS INPUTS Input Power A/B/C models: 90 to 277 Vac line-to-neutral, 50/60 Hz, 8 VA E models: 100 to 277 Vac line-to-neutral, 50/60 Hz, 15 VA ACCURACY Power/Energy IEC 62053-21 Class 1, ANSI C12.1-2008. 1% system accuracy (includes main board and 50 A or 100 A branch CTs) Voltage ±0.5% of reading 90 to 277 Vac line-to-neutral Current ±0.5% of reading Minimum ON Current 50 mA OPERATION Sampling Frequency 2560 Hz Update Rate 2 seconds (when both panels and all circuits are used) Overload Capability 22 kAIC E30/E31 MODEL A, B OR C SERIAL COMMUNICATION Physical Interface DIP switch-selectable 2-wire or 4-wire, RS-485 Protocols Supported Modbus RTU Address Range DIP switch-selectable address 1 to 247 (in pairs of 2) Baud Rate DIP switch-selectable 9600, 19200, 38400 Parity DIP switch-selectable NONE, ODD, EVEN E30/E31 MODEL E SERIAL COMMUNICATION Physical Interface 2-wire RS-485 Protocols Supported Modbus RTU or BACnet MSTP Address Range 1 to 247 for Modbus RTU; 0-127 for BACnet MS/TP Baud Rate 9600, 19200, 38400 Parity Modbus RTU: NONE, ODD, EVEN BACnet MS/TP: NONE (fixed) E30/E31 MODEL E ETHERNET COMMUNICATION Physical Interface RJ45 connector with 10/100 Mbit Ethernet Protocols Supported Modbus TCP, BACnet IP, SNMP V2c concurrently ENVIRONMENTAL Operating Range 0 to 60 °C (32 to 140 °F) (<95% RH non-condensing) Storage Temp Range -40 to 70 °C (-40 to 158 °F) Altitude of Operation 3000 m Mounting Location Not suitable for wet locations. For indoor use only. WARRANTY Limited Warranty 5 years AGENCY APPROVALS Agency Approvals UL508 Listed, EN61010-1, Cat. III, Pollution Degree 2 · A TO R I E S TE S T ING ® B A C n e t · (E31E only) LABOR 35 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Monitoring Multi-Circuit | E30 & E31 Series PRODUCT CAPABILITIES E30A/ E31A MONITORING AT MAINS Current per phase · Max. current per phase · Current demand per phase · Max. current demand per phase · Current phase angle · Energy (kWh) per phase · Real Power (kW) per phase · Apparent Power (kVA) · Power factor total* · Power factor per phase · Voltage, L-L and average · Voltage, L-N and average · Voltage, L-N and per phase · Frequency (phase A) · MONITORING AT BRANCH CIRCUIT Current · Max. current · Current demand · Max. current demand · Current phase angle · Real power (kW) · Real power (kW) demand · Real power (kW) demand max. · Energy (kWh) per circuit · Power factor · Apparent Power (kVA) · V-LL THD, V-LN THD & Current THD % · MODBUS ALARMS Voltage over/under · Current over/under · PROTOCOLS SUPPORTED Modbus RTU · Modbus TCP ** BACnet MS/TP ** BACnet IP with BBMD support ** SNMP V2 ** * Based on a 3-phase breaker rotation. ** With E8951 added. E30B/ E31B · · · · · · · · · · · · · · · · · · · · · ** ** ** ** E30C/ E31C · · · · · · · · · · ** ** ** ** E30E/ E31E · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · A/B/C MODELS MAIN BOARD Dimensional Drawing 8.3" (211 mm) 7.9" (200 mm) 3.9" (100 mm) Ø = 0.2" (5 mm) E MODELS Dimensional Drawing 7.3" (184 mm) 8.9" (226 mm) 5.8" (146 mm) 4.8" (122 mm) 1.75" (45 mm) 12.1" (307 mm) 2x: 5.9" (150 mm) 12.8" (325 mm) 13.9" (353 mm) 2.8" (71 mm) 8.9" (225 mm) 10.0" (253 mm) 8.2" (210 mm) OPERATION EXAMPLE High Alarm Latched AMPS Ch. 1 Low Alarm Ch. 2 Latched 0A TIME No Alarm Latched High High High Low Low Alarm Latched Low Low Low 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 36 63 Power Monitoring Multi-Circuit | Panelboard Monitoring System PANELBOARD Wiring Diagram Monitor Mains Using 0.333 V CTs E30 Solid-Core CT Strips Solid-Core CT Strips E30 Main Board SOLID-CORE BRANCH CTs 100 A SOLID-CORE BRANCH CT Voltage Rating 300 Vac Temperature 0 to 60 °C Agency EN61010-1 Observe precautions for handling static sensitive devices to avoid damage to the circuitry that is not covered under the factory warranty. BRANCH CT STRIPS Dimensional Drawing E30x242 - 42 branch CTs, 3/4" spacing 1.3" (33 mm) 2.0" (50 mm) 20.3" (516 mm) slot: 0.25" x 0.5" (7 x 13mm) 0.4" (10 mm) opening 0.75" (19 mm) on center 1.1" (28 mm) 0.8" (20 mm) E30x242 - 42 branch CTs, 1" spacing 25.0" (635 mm) 1.2" (30 mm) slot: 0.25" x 0.5" (7 x 13mm) 2.0" (50 mm) 0.4" (10 mm) opening 1.0" (26 mm) on center 1.2" (31 mm) 0.8" (20 mm) E30x242 - 42 branch CTs, 18 mm spacing 15.7" (399 mm) 2.0" (50 mm) 1.3" (32 mm) 0.4" (10 mm) opening 0.7" (18 mm) on center E30x236 - 36 branch CTs, 18 mm spacing 1.7" (43 mm) 16.4" (417 mm) 0.9" (21.2 mm) 1.3" (32 mm) 0.4" (10 mm) opening E30x224 - 24 branch CTs, 18 mm spacing 1.7" (43 mm) 12.3" (312 mm) 0.7" (18 mm) on center 0.9" (21.2 mm) 1.3" (32 mm) 0.4" (10 mm) opening 0.7" (18 mm) on center 0.9" (21.2 mm) E30 (SOLID-CORE) ORDERING INFORMATION Description Branch CT Spacing # of Branch CTs & Ribbon Cables E30 A = Advanced B = Intermediate C = Basic E = Advanced w/Ethernet 0 = 100 A, ¾" spacing 1 = 100 A, 1" spacing 2 = 100 A, 18 mm spacing Example: 24 = 2 strips of 12 branch CTs (18 mm only) and two 4-ft. round ribbon cables 36 = 2 strips of 18 branch CTs (18 mm only) and two 4-ft. round ribbon cables 42 = 2 strips of 21 branch CTs (¾", 1", or 18 mm) and two 4-ft. round ribbon cables 48 = 4 strips of 12 branch CTs (18 mm only) and four 4-ft. round ribbon cables 72 = 4 strips of 18 branch CTs (18 mm only) and four 4-ft. round ribbon cables 84 = 4 strips of 21 branch CTs (¾", 1", or 18 mm) and four 4-ft. round ribbon cables E30 A 0 42 NOTE: CTs for mains (not used on C models) must be ordered separately. Use 0 to 0.333V CTs rated for use with Class 1 voltage inputs. Free configuration tool available from www.veris.com. Consult factory for additional mounting options. 37 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Monitoring Multi-Circuit | E30 & E31 Series E31 (SPLIT-CORE) ORDERING INFORMATION 1 Boards Description # of CTs E31 A = Advanced board B = Intermediate board C = Basic board E = Advanced with Ethernet 002 = 2 adapter boards, no CTs, no cables 004 = 4 adapter boards, no CTs, no cables 42 = 2 adapter boards, 42 50A CTs, 2 4 ft. round ribbon cables 84 = 4 adapter boards, 84 50A CTs, 4 4 ft. round ribbon cables Y63 = 2 adapter boards, flat ribbon cables, pre-assembled on one bracket, CTs not included (not available with E31E models) 2 Branch CTs (up to 21 CTs per adapter board) Description E31CT 0 = 6-pack, 50A Branch CT, 6 ft. (1.8 m) lead 0R20 = 6-pack, 50A Branch CT, 20 ft. (6 m) lead 1 = 6-pack, 100A Branch CT, 6 ft. (1.8 m) lead 1R20 = 6-pack, 100A Branch CT, 20 ft. (6 m) lead 3 = Single CT, 200A Branch CT, 6 ft. (1.8 m) lead 3R20 = Single CT, 200A Branch CT, 20 ft. (6 m) lead 3 Ribbon Cable (order 1 cable per adapter board) Description CBL0 31 = Round Ribbon Cable, 18 in. (0.5 m) 32 = Round Ribbon Cable, 30 in. (0.8 m) 22 = Round Ribbon Cable, 4 ft. (1.2 m) 33 = Round Ribbon Cable, 8 ft. (2.4 m) 23 = Round Ribbon Cable, 10 ft. (3 m) 24 = Round Ribbon Cable, 20 ft. (6 m) 08 = Flat Ribbon Cable, 18 in. (0.5 m) 16 = Flat Ribbon Cable, 4 ft. (1.2 m) 17 = Flat Ribbon Cable, 5 ft. (1.5 m) 18 = Flat Ribbon Cable, 6 ft. (1.8 m) 19 = Flat Ribbon Cable, 8 ft. (2.4 m) 20 = Flat Ribbon Cable, 10 ft. (3 m) 21 = Flat Ribbon Cable, 20 ft. (6 m) Ordering Examples: Option A: For monitoring 42 or 84 circuits, order a pre-made kit from Group 1 only (see Application/Wiring Diagram above). Example: E31x42 or E31x84 Option B: For monitoring other configurations, build your own kit by selecting from Groups 1 , 2 , and 3 . Example kit for an 18-circuit panel retrofit: 1 E31A002 - Advanced board, 2 adapter boards (1 unit) 2 E31CT0 - 50A Branch CT six-pack (3 units) 3 CBL023 - 10 ft. round ribbon cable (2 units) NOTE: CTs for mains (not used on E3xC models) must be ordered separately. Use 0 to 0.333 V CTs rated for use with Class 1 voltage inputs. E31 ADAPTER BOARD Dimensional Drawing 1.00" (26 mm) 1.00" (26 mm) 2.75" (70 mm) 4.6" (117 mm) BRANCH CTs Dimensional Drawing D A B C E D B C A E D A B C E E31CT0 50 Amp (0 to 60 Amp Range) A = 1.0" (26 mm) B = 0.5" (11 mm) C = 0.4" (10 mm) D = 0.9" (23 mm) E = 1.6" (40 mm) E31CT1 100 Amp (0 to120 Amp Range) A = 1.5" (39 mm) B = 0.8" (20 mm) C = 0.7" (16 mm) D = 1.6" (40 mm) E = 2.1" (53 mm) E31CT3 200 Amp (0 to 240 Amp Range) A = 1.5" (39 mm) B = 1.25" (32 mm) C = 1.25" (32 mm) D = 2.5" (64 mm) E = 2.8" (71 mm) E31XY63 BOARDS WITH BRACKET Dimensional Drawing 8.75" (222 mm) 9.75" (248 mm) E31 SPLIT-CORE BRANCH CTs 50 A SPLIT-CORE BRANCH CT Voltage Rating 300 Vac Measurement Range 0 to 60 A Temperature Agency 0 to 60 °C UL 61010-1 Recognized, EN61010-1 E31xY63 100 A SPLIT-CORE BRANCH CT 300 Vac (CE), 600 Vac (UL) 0 to 120 A 0 to 60 °C UL 61010-1 Recognized, EN61010-1 200 A SPLIT-CORE BRANCH CT 300 Vac (CE), 600 Vac (UL) 0 to 240 A 0 to 60 °C UL 61010-1 Recognized, EN61010-1 WIRING DIAGRAM Observe precautions for handling static sensitive devices to avoid damage to the circuitry that is not covered under the factory warranty. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 69 38 83 POWER METERING CTs Veris provides a complete line of current transformers/transducers to suit many applications. We offer both voltage and amperage outputs for compatibility with other devices and systems, as well as a variety of core sizes and styles to fit into tight spaces. Browse our extensive offering to find the ideal solution for your needs. MODEL H681x Series E681x/E682x Series SCT Series E683x Series H681x-5A Series AL/BL/CL Series DESCRIPTION 1 V and 0.333 V Output, Medium Current Rating, Split-core 0.333 V Output, Medium Current Rating, Solid-core and Split-core 0.333 V Output, Low Current Rating, Split-core Rope-Style Core AC Current Transducer (for use only with E5xxxA and E2x Series meters) 5A Output, Split-core 5A Output, Solid-core PAGE 41 43 45 47 49 51 METERING CT SELECTION GUIDE SOLID-CORE 5 AMP 1 VOLT MODEL RANGE ID MODEL RANGE ID ALxxx page 51 BLxxx page 51 CLxxx page 51 50 to 400A 60 to 1200A 1200 to 2000A 1.1" (26 mm) 2.0" (52 mm) 3.0" (76 mm) SPLIT-CORE H6810-xxxA-5A page 49 H6811-xxxA-5A page 49 H6812-xxxA-5A page 49 200 to 300A 400 to 800A 800 to 1600A 1.2" x 1.3" (30 x 32 mm) 2.5" x 2.9" (62 x 73 mm) 2.5" x 5.5" (62 x 139 mm) H6810-xxxA-1V page 41 H6811-xxxA-1V page 41 H6812-xxxA-1V page 41 100 to 300A 400 to 800A 800 to 2400A 1.2" x 1.3" (30 x 32 mm) 2.5" x 2.9" (62 x 73 mm) 2.5" x 5.5" (62 x 139 mm) Note: If using an E2x or E5xxxA power meter, order the E683x Rogowski rope style CTs, page 47. 0.333 VOLT MODEL RANGE ID E682Axxxx3 page 43 E682Cxxxx3 page 43 E682Dxxxx3 page 43 E681A051V3 page 43 E681B101V3 page 43 E681C201V3 page 43 H6810-xxxA-0.3V page 41 H6811-xxxA-0.3V page 41 H6812-xxxA-0.3V page 41 SCT-0750-xxx page 45 SCT-1250-xxx page 45 50 to 100A 200A 400A 50A 100A 200A 100 to 300A 400 to 800A 800 to 2400A 5 to 200A 50 to 600A 0.4" (10 mm) 1.0" (25 mm) 1.25" (31 mm) 0.4" (10 mm) 0.6" (16 mm) 1.25" (31 mm) 1.2" x 1.3" (30 x 32 mm) 2.5" x 2.9" (62 x 73 mm) 2.5" x 5.5" (62 x 139 mm) 0.75" (20 mm) 1.25" (32 mm) 39 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com EASILY TRANSFORM ELECTRICAL SERVICE AMPERAGES TO VOLTAGES COMPATIBLE WITH MONITORING EQUIPMENT E683x Series Rogowski CTs APPLICATIONS » Flexible core for an easy installation, even in tough locations » Supports a wide range of amperages, meaning you can always order the same CT, regardless of load size FEATURES FAST CT CONNECTION Built-in power supply and integrator (compatible with E2x and E5xxxA power and energy meters) ENHANCED ACCURACY Phase angle <0.5 degrees measures at 50% rated current 1% ACCURACY From 50 to 5000 A...monitor a wide range of loads with breakers from 400 to 5000 A INSTALLATION EASE AND FLEXIBILITY Flexible core fits in tight enclosures and insulated leads 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 40 Power Metering CTs | Current Tranducers, Voltage H681X SERIES Medium Current Ranges High accuracy ±1% from 10% to 100% of rated current UL Recognized UL Recognized, including UL2808 H681x-V (subset of models shown) 1 V or 0.333 V 1 V or 0.333 V output versions available APPLICATIONS The H681x Series of 1 volt and 0.333 volt split-core current transformers (CTs) provide secondary AC voltage proportional to the primary (sensed) current. For use with power meters, data loggers, chart recorders, and other instruments, the H681x-V series CTs provide a cost-effective means to transform electrical service amperages to avoltage compatible with monitoring equipment. Note: See the H681x-5A Series datasheet for 5A output models. · Data logging · Recording · Power monitoring · Energy management · Alternative energy monitoring · Cost allocation SPECIFICATIONS Split-Core INPUTS Frequency Range Leads ACCURACY Accuracy OUTPUTS Output at Rated Current MECHANICAL Insulation ENVIRONMENTAL Operating Temp Range Storage Temp Range Humidity Range Altitude of Operation Mounting Location WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Installation Category 50/60 Hz 6 ft (1.8 m), 20 ft (6 m) ±1% of reading from 10% to 100% of rated current, specified with the primary conductor(s) centered in the CT window 1 V or 0.333 V 600 Vac 2400A models only: -15 to 50 °C (5 to 122 °F); All other models: -15 to 60 °C (5 to 140 °F) -40 to 70 °C (-40 to 158 °F) 0 to 95% non-condensing 3 km max. Not suitable for wet locations. For indoor use only. 5 years UL61010-1, IEC 61010-1, EN 61010-1 Category III, Pollution Degree 2 UL2808 INPUTS Frequency Range Leads ACCURACY Accuracy OUTPUTS Output at Rated Current MECHANICAL Insulation ENVIRONMENTAL Operating Temp Range Storage Temp Range Humidity Range Altitude of Operation Mounting Location WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Installation Category 50/60 Hz 16 AWG, 8 ft (2.4 m), 20 ft (6 m) These CTs meet or exceed accuracy requirements specified in IEC 61869-2, Table 201, Class 1 1 V or 0.333 V 600 Vac -15 to 60 °C (5 to 140 °F) -40 to 70 °C (-40 to 158 °F) 0 to 95% non-condensing 2 km max. Not suitable for wet locations. For indoor use only. 5 years UL2808 Category III, Pollution Degree 2 41 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Metering CTs | H681x Series SPLIT-CORE Dimensional Drawings F B CD E A F B CD A E F B C A D E H6810/Small H6811/Medium 1ABCDE0=====0123S1H40001-13M.000..6.3.202388AAAA0"""""1Lmmm0((((0(L31339pppA101272mmmmmmpmmmmm))))) A =F = 43..88"" (1(9262mmmm) ) B = 1.5" (38 mm) 4ABCDE0=====052241-.....299582468"M""""0H000((((E(0100076163D342814AAAAI215Ummmmmmm1Mmmpppmpmmmm))))) F =A =6.0" 4(1.95"2 m(12m5 )mm) B = 2.9" (73 mm) C = 1.3" (32 mm) C = 2.5" (62 mm) DE ==WIR31..I91N"" G((1209E0mmXmmA) )MPLE D = 1.1" (29 mm) E = 5.2" (132 mm) F = 4.8" (121 mm) One turnF = 5.9" (151 mm) customer supplied H8ABCD06====0852411-....259522/"""4"L12(((08(1a61603HL0042r0014A06g0005AR8mmAeAAmG1mmmmmmm2Emmpppp)) )) E = 7.9"2(420001Ammmp ) F =A6=.0" (145.92"m(m12)5 mm) B = 5.5" (139 mm) C = 2.5" (62 mm) D = 1.1" (29 mm) E = 7.9" (201 mm) White F = X1 5.9" (151 mm) UL2808 Dimensional Drawings F B CD E A F B CD A E H6810/Small 100 - 400 Amp A = 3.23" (82 mm) B = 1.4" (36 mm) C = 1.4" (36 mm) D = 1.12" (28 mm) E = 3.25" (83 mm) F = 4.12" (105 mm) H6811/Medium 600 - 800 Amp A = 4.95" (126 mm) B = 2.9" (74 mm) C = 2.46" (63 mm) D = 1.2" (31 mm) E = 5.36" (136 mm) F = 5.83" (148 mm) F B C A D E H6812/Large 1000 - 2400 Amp A = 4.91" (125 mm) B = 5.73" (146 mm) C = 2.47" (63 mm) D = 1.16" (30 mm) E = 8.12" (206 mm) F = 4.91" (125 mm) X2 Black ORDERING INFORMATION MODEL* H6810-100A-.3V (R20) H6810-200A-.3V (R20) H6810-300A-.3V (R20) H6811-400A-.3V (R20) H6811-600A-.3V (R20) H6811-800A-.3V (R20) H6812-800A-.3V (R20) H6812-1000A-.3V (R20) H6812-1200A-.3V (R20) H6812-1600A-.3V (R20) H6812-2000A-.3V (R20) H6812-2400A-.3V (R20) H6810-100A-.3VU H6810-200A-.3VU H6810-300A-.3VU H6810-400A-.3VU H6811-600A-.3VU H6811-800A-.3VU H6812-800A-.3VU H6812-1000A-.3VU H6812-1200A-.3VU H6812-1600A-.3VU H6812-2000A-.3VU H6812-2400A-.3VU DESCRIPTION Split-core CT, Size 2, 100 A: 0.333 V Split-core CT, Size 2, 200 A: 0.333 V Split-core CT, Size 2, 300 A: 0.333 V Split-core CT, Size 3, 400 A: 0.333 V Split-core CT, Size 3, 600 A: 0.333 V Split-core CT, Size 3, 800 A: 0.333 V Split-core CT, Size 4, 800 A: 0.333 V Split-core CT, Size 4, 1000 A: 0.333 V Split-core CT, Size 4, 1200 A: 0.333 V Split-core CT, Size 4, 1600 A: 0.333 V Split-core CT, Size 4, 2000 A: 0.333 V Split-core CT, Size 4, 2400 A: 0.333 V Split core CT, .3V, 100A UL2808 Split core CT, .3V, 200A UL2808 Split core CT, .3V, 300A UL2808 Split core CT, .3V, 400A UL2808 Split core CT, .3V, 600A UL2808 Split core CT, .3V, 800A UL2808 Split core CT, .3V, 800A UL2808 Split core CT, .3V, 1000A UL2808 Split core CT, .3V, 1200A UL2808 Split core CT, .3V, 1600A UL2808 Split core CT, .3V, 2000A UL2808 Split core CT, .3V, 2400A UL2808 MODEL* H6810-100A-1V H6810-200A-1V H6810-300A-1V H6811-400A-1V H6811-600A-1V H6811-800A-1V H6812-800A-1V H6812-1000A-1V H6812-1200A-1V H6812-1600A-1V H6812-2000A-1V H6812-2400A-1V H6810-100A-1VU H6810-200A-1VU H6810-300A-1VU H6810-400A-1VU H6811-600A-1VU H6811-800A-1VU H6812-800A-1VU H6812-1000A-1VU H6812-1200A-1VU H6812-1600A-1VU H6812-2000A-1VU H6812-2400A-1VU DESCRIPTION Split-core CT, Size 2, 100 A: 1 V Split-core CT, Size 2, 200 A: 1 V Split-core CT, Size 2, 300 A: 1 V Split-core CT, Size 3, 400 A: 1 V Split-core CT, Size 3, 600 A: 1 V Split-core CT, Size 3, 800 A: 1 V Split-core CT, Size 4, 800 A: 1 V Split-core CT, Size 4, 1000 A: 1 V Split-core CT, Size 4, 1200 A: 1 V Split-core CT, Size 4, 1600 A: 1 V Split-core CT, Size 4, 2000 A: 1 V Split-core CT, Size 4, 2400 A: 1 V Split core CT, 1V, 100A UL2808 Split core CT, 1V, 200A UL2808 Split core CT, 1V, 300A UL2808 Split core CT, 1V, 400A UL2808 Split core CT, 1V, 600A UL2808 Split core CT, 1V, 800A UL2808 Split core CT, 1V, 800A UL2808 Split core CT, 1V, 1000A UL2808 Split core CT, 1V, 1200A UL2808 Split core CT, 1V, 1600A UL2808 Split core CT, 1V, 2000A UL2808 Split core CT, 1V, 2400A UL2808 ACCESSORIES P. 69 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 42 Power Metering CTs | Current Tranducers, Voltage E681X & E682X SERIES Medium Current Ranges High accuracy UL Recognized ±0.5% from 5% to 120% of rated UL Recognized current for E682x or ±1% from 10% to 100% of rated current for E681x 0.333 V output 0.333 V output E681x APPLICATIONS · Data logging · Recording · Power monitoring · Energy management · Alternative energy monitoring · Cost allocation E682x The E681x and E682x Series of current transducers provide a standard voltage output for use with data loggers, chart recorders, and power monitoring equipment. Both series have 0.333 V output. E682x devices are solid-core, while E681x CTs are split-core. SPECIFICATIONS Split-Core Output at Rated Current Accuracy Frequency Range Leads Max. Voltage L-N Sensed Conductor* Operating Temp Range Storage Temp Range Humidity Range Altitude of Operation Installation Category Mounting Location WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 0.333 Vac 1% from 10% to 100% of rated current 50/60 Hz 22 AWG, 600 Vac, UL 1015 bonded pair, 6 ft. (1.8 m) standard length E681A051V3: 300 Vac (basic insulation rating), 150 Vac (reinforced insulation rating) E681B101V3 and E681C201V3: 600 Vac (basic insulation rating), 300 Vac (reinforced insulation rating) 0 to 70 °C (32 to 158 °F) -40 to 105 °C (-40 to 221 °F) 0 to 95% non-condensing 3 km max. Category III, pollution degree 2 Not suitable for wet locations. For indoor use only. 5 years UL 61010-1, IEC 61010-1, EN 61010-1 SPECIFICATIONS Solid-Core Output at Rated Current Accuracy Frequency Range Leads Max. Voltage L-N Sensed Conductor* Operating Temp Range Storage Temp Range Humidity Range Altitude of Operation Agency Approvals Installation Category Mounting Location WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 0.333 Vac ±0.5% of reading from 5% to 120% of rated current 50/60 Hz 22 AWG, 600 Vac, UL 1015 bonded pair, 6 ft. (1.8 m) standard length 600 Vac (basic insulation rating), 300 Vac (reinforced insulation rating) -40 to 85 °C (40 to 185 °F) -50 to 105 °C (-58 to 221 °F) 0 to 95% non-condensing 3 km max. UL61010-1, EN61010-1 Category III, pollution degree 2 Not suitable for wet locations. For indoor use only. 5 years UL 61010-1, IEC 61010-1, EN 61010-1 E207042 43 E207042 * Do not apply these current transducers to circuits having a phase-to-phase voltage greater than the maximum rated voltage (300 Vac or 600 Vac, see above), unless adequate additional insulation is applied between the primary conductor and the current transducers. Veris assumes no responsibility for damage of equipment or personal injury caused by products operated on circuits above their published ratings. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com E681X Dimensional Drawings D A B C E D B C A E D A B C E 50 Amp A = 1.0" (26 mm) B = 0.5" (11 mm) C = 0.4" (10 mm) D = 0.9" (23 mm) E = 1.6" (40 mm) 100 Amp A = 1.2" (29.5 mm) B = 0.6" (16 mm) C = 0.6" (16 mm) D = 1.85" (47 mm) E = 2.1" (53 mm) 200 Amp A = 1.5" (39 mm) B = 1.25" (32 mm) C = 1.25" (32 mm) D = 2.5" (64 mm) E = 2.8" (71 mm) WIRING EXAMPLE One turn customer supplied White X1 X2 Black Power Metering CTs | E681x & E682x Series E682X Dimensional Drawing A C B Ø = E D L 0.250" nominal (6.35 mm nominal) MODEL E682A051V3 E682A101V3 E682C201V3 E682D401V3 L 6' (1.8 m) 6' (1.8 m) 6' (1.8 m) A B C D E 1.3" 1.5" 0.7" 0.8" 0.4" (33 mm) (38 mm) (18 mm) (21 mm) (10 mm) 2.3" (59 mm) 2.8" (70 mm) 2.6" (66 mm) 3.2" (82 mm) 0.7" (18 mm) 1.0" (25 mm) 1.2" (31 mm) 1.4" (36 mm) 1.0" (25 mm) 1.25" (31 mm) ORDERING INFORMATION Split-core MODEL DESCRIPTION E681A051V3 Split-core CT, 50 A: 0.333 V, 0.4 in ID, 6 ft leads E681B101V3 Split-core CT, 100 A: 0.333 V, 0.6 in ID, 6 ft leads E681C201V3 Split-core CT, 200 A: 0.333 V, 1.25 in ID, 6 ft leads Solid-core MODEL DESCRIPTION E682A051V3 Solid-core CT, 50 A: 0.333 V, 0.4 in ID, 6 ft leads E682A101V3 Solid-core CT, 100 A: 0.333 V, 0.4 in ID, 6 ft leads E682C201V3 Solid-core CT, 200 A: 0.333 V, 1.0 in ID, 6 ft leads E682D401V3 Solid-core CT, 400 A: 0.333 V, 1.25 in ID, 6 ft leads Note: Other lead lengths are available. Consult factory. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 44 Power Metering CTs | Current Transducers, Voltage Output SCT SERIES Low Current Ranges High accuracy ±1% from 10% to 130% of rated current Interleaving joints Interleaving joints for reliability with a self-locking mechanism and no exposed metal Compatible with existing systems 0.333 Vac standard output UL Recognized UL Recognized SCT SCT AC current sensors have center hole sizes and current ratings to suit many application. SCT models have a split core that is perfect for retrofits. Output is the industry standard of 0.333 Vac. SPECIFICATIONS INPUTS Frequency Range Leads ACCURACY Accuracy OUTPUTS Output @ Rated Current MECHANICAL Insulation ENVIRONMENTAL Installation Category III Operating Temp Range Storage Temp Range WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals * 50 to 400 Hz 8 ft (2.43 m) ±1% of reading from 10% to 130% of rated current 0.333 Vac 600 Vac Pollution Degree 2 -10 to 55 °C (14 to 131 °F) -40 to 70 °C (-40 to 158 °F) 3 years cURus, ANSI/IEEE 57.13, CE, RoHS E96927 *The CE mark indicates RoHS2 compliance. APPLICATIONS · Data logging · Recording · Power monitoring · Energy management · Alternative energy monitoring · Cost allocation 45 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com WIRING EXAMPLE One turn customer supplied White X1 X2 Black ORDERING INFORMATION MODEL U004-0030 U004-0031 U004-0032 U004-0033 U004-0034 U004-0035 U004-0036 U004-0037 U004-0039 U004-0040 U004-0041 U004-0042 U004-0043 U004-0044 U004-0045 U004-0046 MANUF. PART RATING NUMBER (A) DESCRIPTION SCT-0750-005 5 CT, Split-core, 5 A: 0.333 Vac, 0.750" ID SCT-0750-010 10 CT, Split-core, 10 A: 0.333 Vac, 0.750" ID SCT-0750-030 30 CT, Split-core, 30 A: 0.333 Vac, 0.750" ID SCT-0750-050 50 CT, Split-core, 50 A: 0.333 Vac, 0.750" ID SCT-0750-070 70 CT, Split-core, 70 A: 0.333 Vac, 0.750" ID SCT-0750-100 100 CT, Split-core, 100 A: 0.333 Vac, 0.750" ID SCT-0750-150 150 CT, Split-core, 150 A: 0.333 Vac, 0.750" ID SCT-0750-200 200 CT, Split-core, 200 A: 0.333 Vac, 0.750" ID SCT-1250-070 70 CT, Split-core, 70 A: 0.333 Vac, 1.250" ID SCT-1250-100 100 CT, Split-core, 100 A: 0.333 Vac, 1.250" ID SCT-1250-150 150 CT, Split-core, 150 A: 0.333 Vac, 1.250" ID SCT-1250-200 200 CT, Split-core, 200 A: 0.333 Vac, 1.250" ID SCT-1250-250 250 CT, Split-core, 250 A: 0.333 Vac, 1.250" ID SCT-1250-300 300 CT, Split-core, 300A : 0.333 Vac, 1.250" ID SCT-1250-400 400 CT, Split-core, 400 A: 0.333 Vac, 1.250" ID SCT-1250-600 600 CT, Split-core, 600 A: 0.333 Vac, 1.250" ID Power Metering CTs | SCT Series DIMENSIONAL DRAWING E D A B C MODEL SCT-0750-xxx SCT-1250-xxx A 2.0" (51 mm) 3.25" (83 mm) B 2.1" (54 mm) 3.35" (86 mm) C 0.61" (16 mm) 1.0" (26 mm) D 0.75" (20 mm) 1.25" (32 mm) E 0.75" (20 mm) 1.25" (32 mm) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 46 Power Metering CTs | Rogowski Flexible Core AC Current Transducer E683X SERIES Exclusively for E2x and E5xxxA Power and Energy Meters (sold separately) EACH CT MEASURES 50 TO 5000 A! Easy installation Insulated leads Maximum flexibility Fits difficult spaces UL Recognized UL Recognized 1% accuracy 1% accuracy from 50 to 5000 A... monitor a wide range of loads with breakers from 400 to 5000 A E683x Series (U018 equivalent) The E683x Series of Rogowski flexible rope style current transducers (CTs) provide secondary AC voltage proportional to the primary (sensed) current. For use with E5xxxA and E2x Series power meters, the E683x Series CTs provide a cost-effective means to transform electrical service amperages to a voltage compatible with monitoring equipment. The flexible core makes it easy to fit in tight enclosures. These products provide reinforced insulation between the sensed conductor and the output leads. The E683x Series works exclusively with the E2x and E5xxxA power and energy meters and is a U018 equivalent. These meters have a built-in power supply and integrator, so CT connection is fast and simple. Fast CT connection Enhanced accuracy Compatible with E2x and E5xxxA power and energy meters with built-in power supply and integrator for fast CT connection... see the E2xxx and E5xxxA datasheets Phase angle <0.5 degrees, measured at 50% rated current APPLICATIONS · Data logging · Recording · Power monitoring · Energy management · Alternative energy monitoring · Cost allocation SPECIFICATIONS INPUTS Frequency Range Cable ACCURACY Accuracy OUTPUT Output at Rated Current MECHANICAL Insulation category ENVIRONMENTAL Installation Category IV Operating Temp. Range Storage Temp. Range WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 50/60 Hz 1000 Vac UL Style 21223 cable with 22 AWG leads ±1% from 50 to 5000 A Custom for E5xxxA and E2x Series power meters 600 V Cat lV, Pollution Degree 2 Pollution Degree 2 -15 to 60 °C (5 to 140 °F) -40 to 70 °C (-40 to 158 °F) 3 years EN61010-1; UL61010-1; EN61010-2-032; UL61010-2-032 E96927 47 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING 1.05 in. (26.50 mm) 2.84 in. (72 mm) 8 ft. (2.45 m) 7.7 ft. (2.35 m) 3.13 in. (80 mm) 3.76 in. (96 mm) 5.76 in. (146 mm) 7.52 in. (191 mm) 11.28 in. (287 mm) (FOR REFERENCE ONLY) 0.33 in. (8.3 mm) 9 in. (250 mm) 12 in. (300 mm) 18 in. (460 mm) 24 in. (600 mm) 36 in. (900 mm) CT CORE LENGTH 9 in. (250 mm) 12 in. (300 mm) 18 in. (460 mm) 24 in. (600 mm) 36 in. (900 mm) APPROXIMATE INSIDE DIAMETER WITH CLOSED CONNECTOR Ø 3.13 in. (80 mm) Ø 3.76 in. (96 mm) Ø 5.76 in. (146 mm) Ø 7.52 in. (191 mm) Ø 11.28 in. (287 mm) ORDERING INFORMATION MODEL E683C502 E683D502 E683G502 E683J502 E683L502 DESCRIPTION Rogowski CT, 250 mm (9"), 600 V, 5 kA, U018 equivalent Rogowski CT, 300 mm (12"), 600 V, 5 kA, U018 equivalent Rogowski CT, 460 mm (18"), 600 V, 5 kA, U018 equivalent Rogowski CT, 600 mm (24"), 600 V, 5 kA, U018 equivalent Rogowski CT, 900 mm (36"), 600 V, 5 kA, U018 equivalent Note: These CTs are compatible with the E2x and E5xxxA Series meters only. Power Metering CTs | E683x Series 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 48 Power Metering CTs | Current Transformers, 5A Outputs H681X-5A SERIES Split-Core Current Transformers, 5A Output Easy installation Unique hinge design UL Recognized UL Recognized, including UL2808 5 Amps standard 5 Amp standard output... compatible with existing systems H681x-5A (subset of models shown) H681x-5A split-core current transformers (CTs) provide secondary amperage proportional to the primary (sensed) current. For use with power meters, data loggers, chart recorders, and other instruments, the H681x Series 5 Amp CTs provide a cost-effective means to transform electrical service amperages to a 0 to 5 Amp level compatible with monitoring equipment. APPLICATIONS · Data logging · Recording · Power monitoring · Energy management · Alternative energy monitoring · Cost allocation SPECIFICATIONS Split-core INPUTS Frequency Range Leads ACCURACY Accuracy OUTPUTS Output at Rated Current MECHANICAL Insulation ENVIRONMENTAL Operating Temp Range Storage Temp Range Humidity Range Altitude of Operation Mounting Location WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Installation Category 50/60 Hz 6 ft (1.8 m) ±1% of reading from 5% to 100% of rated current, specified with the primary conductor(s) centered in the CT window. 5 A 600 Vac 2400A models only: -15 to 50 °C (5 to 122 °F); All other models: -15 to 60 °C (5 to 140 °F) -40 to 70 °C (-40 to 158 °F) 0 to 95% non-condensing 3 km max. Not suitable for wet locations. For indoor use only. 5 years UL61010-1, IEC 61010-1, EN 61010-1 Category III, Pollution Degree 2 E207042 E150462 UL2808 INPUTS Frequency Range Leads ACCURACY Accuracy OUTPUTS Output at Rated Current MECHANICAL Insulation ENVIRONMENTAL Operating Temp Range Storage Temp Range Humidity Range Altitude of Operation Mounting Location WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Installation Category 50/60 Hz 16 AWG, 8 ft (2.4 m), 20 ft (6 m) These CTs meet or exceed accuracy requirements specified in IEC 61869-2, Table 201, Class 1 (not applicable for small aperture CTs, 200-300 A). 5 A 600 Vac -15 to 60 °C (5 to 140 °F) -40 to 70 °C (-40 to 158 °F) 0 to 95% non-condensing 2 km max. Not suitable for wet locations. For indoor use only. 5 years UL2808 Category III, Pollution Degree 2 E207042 E150462 49 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Metering CTs | E681x-5A Series DIMENSIONAL DRAWINGS Split-Core F B CD E A F B CD A E H6810/Small H260801-3000 Amp SMALL ABCD123====0000001113AAA....2238mmm""""ppp((((33391126mmmmmmmm)))) A = E =3.84".0"(9(160m0mm)m) B = C = F =11..534"".8"((33(1822mm1mmm)) m) D = 1.1" (29 mm) WFE ==IRI43N..89G"" ((E1102X01 mmAmmM)) PLE H6811/Medium 400-8H06081A1mp MEDIUM A B C D = = = = 2241....9546892""000""((000((7613AAA3221mmm5mmmpppmmmmm))) ) EA==5.2"4(.193" 2(m12m5 m) m) FBC===6.0"22(..159""52((m6723mmm)mm)) D = 1.1" (29 mm) E = 5.2" (132 mm) F = 5.9" (151 mm) F B C A D E H6812/LaHrg6e812 800-2400 ALAmRpGE A B C = = = 524...559"""(((1613221289560m000mm0m00AmmAA)mmm)) ppp D = 1.2" (3124m00mA)mp E = 7A.9=" (2014.9m"m()125 mm) F = 6.BC0="=(15252..m55""m)((16329mmmm) ) D = 1.1" (29 mm) E = 7.9" (201 mm) F = 5.9" (151 mm) One turn customer supplied White X1 Black X2 UL2808 F B CD E A H6810/Small UL2808 200-400 Amp A = 3.23" (82 mm) B = 1.4" (36 mm) C = 1.4" (36 mm) D = 1.12" (28 mm) E = 3.25" (83 mm) F = 4.12" (105 mm) F B CD A E H6811/Medium UL2808 600-800 Amp A = 4.95" (126 mm) B = 2.9" (74 mm) C = 2.46" (63 mm) D = 1.2" (31 mm) E = 5.36" (136 mm) F = 5.83" (148 mm) F B CD E A H6812/Large UL2808 1000-2400 Amp A = 4.91" (125 mm) B = 5.73" (146 mm) C = 2.47" (63 mm) D = 1.16" (30 mm) E = 8.12" (206 mm) F = 4.91" (125 mm) ORDERING INFORMATION MODEL DESCRIPTION H6810-200A-5A Split-core CT, Small, 200A:5A H6810-300A-5A Split-core CT, Small, 300A:5A H6811-400A-5A Split-core CT, Medium, 400A:5A H6811-600A-5A Split-core CT, Medium, 600A:5A H6811-800A-5A Split-core CT, Medium, 800A:5A H6812-800A-5A Split-core CT, Medium, 800A:5A H6812-1000A-5A Split-core CT, Large, 10 00A:5A H6812-1200A-5A Split-core CT, Large, 1200A:5A H6812-1600A-5A Split-core CT, Large, 1600A:5A H6812-2000A-5A Split-core CT, Large, 2000A:5A H6812-2400A-5A Split-core CT, Large, 2400A:5A H6810-200A-5AU Split core CT, Small, 5A, 200A UL2808 H6810-300A-5AU Split core CT, Small, 5A, 300A UL2808 H6810-400A-5AU Split core CT, 5A, Small, 400A UL2808 H6811-600A-5AU Split core CT, Medium, 5A, 600A UL2808 H6811-800A-5AU Split core CT, Medium, 5A, 800A UL2808 H6812-800A-5AU Split core CT, Large, 5A, 800A UL2808 H6812-1000A-5AU Split core CT, Large, 5A, 1000A UL2808 H6812-1200A-5AU Split core CT, Large, 5A, 1200A UL2808 H6812-1600A-5AU Split core CT, Large, 5A, 1600A UL2808 H6812-2000A-5AU Split core CT, Large, 5A, 2000A UL2808 H6812-2400A-5AU Split core CT, Large, 5A, 2400A UL2808 Note: Burden rating capacity (VA) available upon request. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 69 50 Power Metering CTs | Current Transformers, 5A Outputs AL, BL & CL SERIES Solid-core Designs UL Recognized UL Recognized 5 Amps standard 5A standard output ... compatible with existing systems AL BL APPLICATIONS · Data logging CL · Recording · Power monitoring Veris AL, BL and CL solid-core current transformers provide a 0 to 5A AC output for use with transducers, data loggers, and chart recorders. SPECIFICATIONS INPUTS Frequency Range Leads ACCURACY Accuracy OUTPUTS Output at Rated Current MECHANICAL Insulation ENVIRONMENTAL Operating Temp Range Storage Temp Range Mounting Location WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 50 to 400 Hz 2 ft (0.6 m) Specified at 60 Hz (see Ordering Information) 5 A 600 Vac (basic) -30 to 55 °C (-22 to 131 °F) -30 to 105 °C (-22 to 221 °F) Not suitable for wet locations. For indoor use only. 1 year ANSI/IEEE C57.13, "Standard Requirements for Instrument Transformers," IEEE C57.13.2, "IEEE Standard Conformance Test Procedures for Instrument Transformers," and cURus. WIRING EXAMPLE One turn customer supplied E93779 · Energy management · Alternative energy monitoring · Cost allocation White X1 Black X2 51 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com AL/BL/CL Dimensional Drawings AL/SMALL 50 Amp, 100 Amp, 150 Amp, 200 Amp, 250 Amp, 300 Amp, 400 Amp A = 2.7" (70 mm) B = 2.5" (63 mm) C = 1.1" (26 mm) D = 1.1" (26 mm) BL/MEDIUM 500 Amp, 600 Amp, 800 Amp, 1000 Amp, 1200 Amp A = 3.7" (90 mm) B = 3.4" (88 mm) C = 2" (52 mm) D = 1.1" (26 mm) CL/LARGE 1200 Amp, 1500 Amp, 1600 Amp, 2000 Amp A = 4.9" (124 mm) B = 4.5" (115 mm) C = 3" (76 mm) D = 1.1" (26 mm) Power Metering CTs | AL, BL & CL Series ORDERING INFORMATION MODEL AL500 AL101 AL151 AL201 AL251 AL301 AL401 BL501 BL601 BL801 BL102 BL122 CL122 RATIO 50:5 100:5 150:5 200:5 250:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1200:5 ACCURACY AT 60 Hz 3% 1% BURDEN CAPACITY IN VA 2.0 2.0 4.0 4.0 6.0 8.0 10.0 12.5 15.0 8.0 10.0 12.5 10.0 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 69 52 NETWORK INTEGRATION Veris Network Integration devices allow the collection, storage, transmission, and display of power monitoring information. Devices include data loggers, signal conditioners, wireless transmitters, protocol converters, and local displays for power monitoring projects and installations, helping you to complete a solution. MODEL H8822 A7810/A8810 A8332-8F2D A8911-23 H8932/H8936 E8951 U0012-0012/U0012-0013 & U013-0015 DESCRIPTION Data Acquisition System, Full-featured Model Data Acquisition Systems, For Embedded Applications Flexible I/O Module Pulse Input Module Network Display Modbus-to-BACnet Protocol Converter Modbus Gateway/BACnet Router PAGE 55 57 59 61 63 65 67 NETWORK INTEGRATION SELECTION GUIDE FEATURES Add Modbus TCP (Ethernet) Communication to a Modbus Meter Add BACnet MS/TP (Serial) Communication to a Modbus Meter Add BACnet IP (Ethernet) Communication to a Modbus Meter Add BACnet IP (Ethernet) Communication to a BACnet MS/TP Meter Add SNMP (Ethernet) Communication to an E30A/E31A Meter Log Data from Modbus Devices Access a Modbus Meter with a Web-Enabled Interface Access Pulse Output Meters/Sensors with a Web-Enabled Interface Generate Alarm Notifications from Modbus Devices Convert Pulse/Analog Outputs to Modbus Add a Local Display to a Modbus (Serial) Meter Add Local Control of Alarms to a Modbus Multi-Circuit Meter MODEL H8822, A8810, U013-0012 E8951 E8951 U013-0013/U013-0015 E8951 H8822, A8810 H8822, A8810 A7810 H8822, A8810 A8332-8F2D, A8911-23 H8936 H8936 PAGE 55, 57, 67 65 65 67 65 55, 57 55, 57 57 55, 57 59, 61 63 63 53 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NEED BACNET, BUT YOUR METER COMMUNICATES MODBUS? E8951 Protocol Converter APPLICATIONS » Pre-configured to support all Veris meters » Automatically detects supported Modbus devices and configures BACnet objects, no programming or setup required » Easily integrate Modbus meters into Building Automation Systems FEATURES MULTI-COMMUNICATE Supports BACnet IP and Modbus TCP access simultaneously A GREAT INTEGRATION TOOL Compatible with Veris' H80xx Series, H8163 with H8163-CB, E5x Series, and E3x Series POINTS OF COLLECTION Each converter can support over 10,000 BACnet measurement points for maximum data collection 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 54 Network Integration | Data Acquisition Systems H8822 ACQUISUITETM Modbus Protocols, Data Logging and Server Capabilities H8822 Plug and play Install and configure in minutes LCD display Easy installation and troubleshooting Flexible data formats Hardware and software provide data in flexible, industrystandard formats for databases, spreadsheets, etc. Integrated web server Provides setup and configuration using any standard web browser The H8822 AcquiSuiteTM data acquisition system is the perfect do-ityourself solution for your energy logging needs. This server combines the flexibility of Ethernet communication with a low installed cost. It is an ideal device for recording electrical, natural gas, water, and other building energy usages. The AcquiSuite has eight flexible I/O options. After installation, data from a connected device is time-stamped and stored in nonvolatile memory at user-selected intervals until the next scheduled upload to the SQL database server. The AcquiSuite sends data to the Building Manager OnlineTM server or to other third party software providers. APPLICATIONS · Aggregating energy and operational information from remote sites · Gathering "near real-time" performance data · Developing load profiles for energy purchases · Measurement and verification SPECIFICATIONS Input Power Operating System Flash ROM Memory LEDs LCD LAN Protocols Serial Port Interval Recording Inputs Outputs PROCESSORS Main Processor I/O Co-Processor 120 to 240 Vac 50/60Hz transformer to 24 Vdc, included Linux 16 MB NOR Flash (expandable with USB memory device) 32 MB RAM 8x pulse input, 4 modem activity, Modbus TX/RX, power status 2 x 16 LCD character, two buttons 10/100, auto-crossover detection Modbus/RTU, Modbus/TCP, TCP/IP, PPP, HTTP/HTML, FTP, SNMP, SMTP, XML RS-485 Modbus User selectable 1 to 60 minutes. Default 15-minute interval. 8x, user selectable - 0-10V - Min/Max/Ave/Instantaneous; 4 to 20 mA- Min/Max/Ave/Instantaneous; Pulse - Consumption, Rate; Resistance - Min/Max/Ave/Instantaneous; Runtime - Runtime, Status 2x, Dry contact 30VDC, 150mA max. ARM 9 ARM 7 MODEMS Phone V.34 bis, 33,600 bps (H8822) WARRANTY Limited Warranty 2 years AGENCY APPROVALS Agency Approvals FCC Part 15, Class A Note: Indoor use only. 55 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Network Integration | H8822 AcquiSuiteTM APPLICATION EXAMPLE The Internet BMO Webserver Cellular (H8822GSM) AcquiSuiteTM Server E5xCx WAN Local Area Network Ethernet 4-20mA Analog devices can connect to on-board H8923-4 as well H8163 E2x Pulse Analog A8332 Modbus Converter E3x PULSE DEVICES (Gas/Water Meters) ANALOG DEVICES (Temperature, Humidity, Air Quality, etc.) DIMENSIONAL DRAWING 8.2 in (209 mm) 2.0 in (51 mm) 9.3 in (77 mm) THE ACQUISUITE SYSTEM ALLOWS Internet Display of Data Using the BMO Website View performance data in an easy graphical format. Store, display, and download historical data in a secure SQL database. Design custom views of data from one or more buildings or systems. Security and Flexibility Store data on board in non-volatile memory. Protect information in the event of a power failure. Time-stamp all interval data with an on-board real-time clock. Compatibility with Existing Systems Use the I/O module to connect to existing sensors and meters. Use TCP/IP protocols to interface with spreadsheets, databases, text files, etc. ORDERING INFORMATION MODEL DESCRIPTION H8822 AcquiSuite Demand Response System: 8 Flexible I/O Inputs 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 56 Network Integration | Data Acquisition Server A7810 ACQUILITETM & A8810 ACQUISUITETM Flexible Data Servers for Embedded Applications Track data in real time Provides the right information for trending, planning, and identifying waste Alarm notification For data points above or below target levels...quick notification for optimal performance maintenance Industrial temp. Communications A8810 range Industrial temperature range (-30 to 70 °C), perfect for embedded applications...speeds up development and integration of energy data Compatible with multiple communication protocols... push or pull data to energy dashboards and software applications for easy system integration A7810 The A7810 AcquiLiteTM and A8810 AcquiSuiteTM data acquisition server for embedded applications allows users to collect energy data from meters and environmental sensors and send it via Modbus communication protocol (wired or wireless using the H8830) to IP-based applications. No software is required. Operation is plug-and-play, and information can be accessed using any web browser. The A7810 supports four pulse inputs, while the A8810 suppports Modbus serial input. The compact housing and industrial temperature range make the A7810 and A8810 ideal for embedded applications. Reduce development time and speed up integration by collecting and distributing energy data directly from your equipment. Easy installation DIN rail mounting APPLICATIONS · Measurement and verification (M&V) · Reduce energy costs · Access energy information from local and remote sites · Benchmark building energy usage · Demand response · Renewable energy SPECIFICATIONS Input Power Isolation A7810 A8810 Main Processor Operating System Flash ROM Memory LEDs A7810 A8810 Console Interval Recording Pulse Inputs A7810 Serial Port Input A8810 24 Vdc, 500 mA* RJ45 Ethernet isolated to 1500 Vdc from main board (power and pulse inputs not isolated) RJ45 Ethernet and RS-485 port isolated to 1500 Vdc from main board (power and USB not isolated) ARM 9 embedded CPU Linux 2.6 16 MB NOR Flash 32 MB RAM Ethernet, pulse (x4), power, alarm Ethernet, Modbus TX/RX, power, alarm 2 x 16 LCD character, two push buttons 1 to 60 minutes, user selectable (default 15 minutes) 4 inputs, dry contact, standard or KYZ, closure threshold 100 to 2.5 k user selectable; max. rate 10 Hz; min. width 50 msec RS-485 Modbus, supports up to 32 external devices (expandable) COMMUNICATION Protocols A7810 A8810 Modbus/TCP, TCP/IP, PPP, HTTP/HTML, FTP, NTP, XML, SNMP-Trap Modbus/RTU, Modbus/TCP, TCP/IP, PPP, HTTP/HTML, FTP, NTP, XML, SNMP-Trap LAN RJ45 10/100 Ethernet, auto polarity ENVIRONMENTAL Operating Temp Range -30 to 70 °C (-22 to 158 °F) Operating Humidity Range 0 to 95% RH non-condensing; indoor use only WARRANTY Limited Warranty 2 years AGENCY APPROVALS A7810 A8810 FCC CFR 47 Part 15, Class A; EN 61000; EN 61326; UL61010 recognized; EN 61010 CE; FCC Part 15, Class A; EN 61000; EN 61326; UL61010 recognized *This unit is to be sourced by a Class 2 power supply with the following output: 24 Vdc, 500 mA min. not to exceed 8 A. 57 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Network Integration | A7810 AcquiLiteTM & A8810 AcquiSuiteTM A7810 Application Example The Internet BMO Webserver AcquiSuiteTM A7810 Server Pulse Output WAN Local Area Network Ethernet Pulse Output E5xBx Energy Meter A8810 Application Example H8163 Enhanced Data Stream Energy Meter The Internet BMO Webserver E5xCx AcquiSuiteTM A8810 Server WAN Local Area Network Ethernet ® H8163 E2x Pulse Analog A8332 Modbus Converter PULSE DEVICES (Gas/Water Meters) E30 ANALOG DEVICES (Temperature, Humidity, Air Quality, etc.) A7810 & A8810 Dimensional Drawing 4.25" (108 mm) 3.9" (99 mm) 4.1" (105 mm) 3.4" (86 mm) 3.25" (83 mm) THE ACQUISUITE SYSTEM ALLOWS Internet Display of Data Using the BMO Website View performance data in an easy graphical format. Store, display, and download historical data in a secure SQL database. Design custom views of data from one or more buildings or systems. Security and Flexibility Store data on board in non-volatile memory. Protect information in the event of a power failure. Time-stamp all interval data with an on-board real-time clock. Compatibility with Existing Systems Use the I/O module to connect to existing sensors and meters. Use TCP/IP protocols to interface with spreadsheets, databases, text files, etc. (A8810 only). ORDERING INFORMATION MODEL A7810 A8810 DESCRIPTION AcquiLite EMB data acquisition server, pulse input AcquiSuite EMB data acquisition server, Modbus serial input 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 58 Network Integration | Flexible I/O Module A8332-8F2D Pulse/Analog-to-Modbus Converter Connect up to eight sensors Connect up to eight industrystandard sensors to the AcquiSuite data acquisition network DIP switch Field-selectable address DIP switch...no software or PC configuration required at device A8332-8F2D The A8332-8F2D Input Module provides a convenient way to optimize energy use and accurately allocate costs. Add eight standard pulse and/or analog sensors to a data acquisition network. Integrate your Veris network sensors through the A8332-8F2D to a Veris H8822 Data Acquisition Server. The A8332-8F2D is the first truly flexible input module that allows incorporation of virtually any industry-standard sensor through a single device. The module can be incorporated with cost-effective data acquisition and wireless metering solutions such as the H8822 AcquiSuite DRTM server, which, as a properly integrated system, provides high performance and low cost. This system can be incorporated into a new or existing Building Automation System (BAS). Using the AcquiSuite data acquisition system, users can set input types (pulse, analog, resistive, etc.), giving access to real time resource consumption for a facility on a single board. SPECIFICATIONS Processor ARM 7, field upgradable firmware LED 8 input status LEDs (red), 2 Modbus TX/RX (yellow), 1 power/alive status (green) Protocols Modbus/ RTU Power Supply 24 Vdc, 200 mA (not included) Serial Port RS-485 Modbus, 19200 or 9600 baud. 8N1 Inputs 8x, user selectable; 0-10V: Min/Max/Ave/Instantaneous; 4 to 20 mA: Min/Max/Ave/Instantaneous; Pulse: Consumption, Rate; Resistance: 0 to 10 V: Min/Max/Ave/Instantaneous Maximum Pulse Rate 10 Hz Contact Closure Threshold 1 k Isolation RS-485 port is optically isolated OPERATING ENVIRONMENT Indoor use only; -30 to 70 °C (32 to 122 °F), 0 to 95% RH non-condensing WARRANTY Limited Warranty 2 years Universal inputs Universal inputs simplify setup... just connect sensors and select device output type via the AcquiSuite or using Obvius configuration software LEDs Check device status at a glance... LED indicators allow for fast recognition of on/off status, TX/ RX communications, and 8 input notifications APPLICATIONS · Demand response program control and reporting · Cost allocation to tenants and third parties · Measurement and verification of energy savings High reliability Non-volatile memory retains configuration and pulse data during power failures Prevent data loss All configuration information and input data is stored in nonvolatile memory to prevent data loss in the event of power failure · Converting pulse inputs from water and gas flow meters to a Modbus network · Monitoring performance of building systems (e.g., chillers, boilers, fans) 59 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com APPLICATION EXAMPLE RS 485 Modbus H8822 MODBUS ENERGY METERS (E2x Enercept) Network Integration | A8332-8F2D DIMENSIONAL DRAWING 4.2" (106 mm) PC or Server with Modem or Ethernet Connection Local PC H8163 with Comms Board Option A8332 Modbus Converter PULSE DEVICES (Gas/Water Meters) ANALOG DEVICES (Temperature, Humidity, Air Quality, Etc.) ORDERING INFORMATION MODEL MANUF. PART # U013-0011 A8332-8F2D DESCRIPTION Flexible I/O Module 1.2" (31 mm) 3.4" (86 mm) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 60 Network Integration | Pulse Input Module A8911-23 Up to 23 Separate Pulse Inputs 4000 ft. communication External communications via shielded twisted pair 18 to 22 gauge wire...allows communication up to 4000 feet DIP switches Onboard DIP switches for Modbus addressing A8911-23 The A8911-23 Input Module provides an easy way to integrate multiple pulse output devices to Modbus systems such as the Veris AcquiSuite data acquisition network. The A8911-23 accepts up to 23 standard pulse sensors and can function as a slave device with any Modbus master. This data can be networked to other critical energy sensors such as Veris Modbus power meters to provide a comprehensive energy monitoring solution. 200 ft. pulse communication Pulse input communication up to 200 feet using 18 to 24 gauge control wire DIN rail mount Quick and easy installation Pulse inputs Industry standard pulse inputs connect to most pulse output meters LED verification LED verification of RS-485 Modbus TX/RX communications SPECIFICATIONS Processor LED Protocols Power Supply Serial Port Pulse Inputs MINIMUM PULSE WIDTH 10 Hz Mode 50 Hz Mode 100 Hz Mode Contact Closure Threshold Isolation OPERATING ENVIRONMENT WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals ARM 7, field upgradable firmware 23 input status LEDs (red), 2 Modbus TX/RX (yellow), 1 power/alive status (green) Modbus/ RTU 9 Vdc to 30 Vdc, 200 mA (not included) RS-485 2-wire, 19200 or 9600 baud. N81 23 independent pulse count inputs; 32-bit pulse counter; rolls over at 4.295 billion per channel; Intended for use with dry contact outputs; pulse count values stored in nonvolatile memory; Pulse rate/width user selectable to 10 Hz, 50 Hz, or 100 Hz APPLICATIONS · Demand response program control and reporting · Cost allocation to tenants and third parties · Measurement and verification of energy savings · Gas, water, steam, and BTU meters · Monitoring performance of building systems (e.g., chillers, boilers, fans) 50 msec 10 msec 5 msec 100 to 5 k (user selectable) Pulse inputs, power inputs and RS-485 are non-isolated Indoor use only; 0 to 50 °C (32 to 122 °F), 0 to 95% RH non-condensing 2 years FCC CFR 47 Part 15, Class A 61 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Network Integration | A8911-23 APPLICATION EXAMPLE DIMENSIONAL DRAWING H8822 RS 485 Modbus PC or Server with Modem or Ethernet Connection Local PC A8911-23 MODBUS ENERGY METERS (E2x Enercept) BRANCH POWER METER (E30) H8163 with Comms Board Option 4.2" (106 mm) 1.2" (31 mm) 3.4" (86 mm) Up to 23 standard pulse output devices ORDERING INFORMATION MODEL MANUF. PART # U013-0010 A8911-23 DESCRIPTION Pulse input module (up to 23 standard pulse devices) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 62 Network Integration | Network Display H8932 & H8936 Modbus-to-Bridgepoint Pass-through communications Pass-through communications to other Modbus® devices Monitor from a single location Monitor a variety of Veris power transducers from a single location Multi-color LED Shows alarm status at a glance Simple setup Easy keypad setup H8936 H8932 The H8932/H8936 serves as a display for Modbus data. The product sits in series between downstream metering devices and the upstream master, providing a display of the data passing through it. Registers of the E50Cx and E51Cx energy monitors can be viewed. The E30 and E31 meters are also supported, but the H8932/H8936 only presents a subset of the most important data points measured. The H8936 is enclosed in a box for easy installation, while the H8932 is available with no box for fast mounting to a panel. SPECIFICATIONS AC Power Source 120 Vac 50/60 Hz, line-to-neutral; internal fuse Fuse Ratings 200 mA@250 5x20 mm Fast-Blow AC Power Voltage Tolerance (90 to 132 Vac) for 120 V AC Power Frequency 50/60 Hz AC Power Termination 2-position Euro-style pluggable connector (max. wire size 12 gauge) Alternate DC Power Source 12 Vdc, 300 mA external current limiting required (auxiliary input disabled if line connected) Terminal Block Torque 4.9 in-lb (0.56 N-m) Operating Temperature Range 0 to 50 °C (32 to 122 °F); <95% RH non-condensing; indoor use only Storage Temperature Range -20 to 70 °C (-4 to 158 °F) NETWORK COMMUNICATIONS Interface Downstream: RS-485; Upstream: RS-485, RS-232 Protocol Modbus RTU Baud Rate UI-selectable 2400, 4800, 9600, 19200 Parity UI-selectable NONE, ODD, EVEN Communication Format 8 data bits, 1 start bit, 1 stop bit RS-485 ¼ load transceivers; duplex is UI-selectable 2-wire or 4-wire; 5-position Euro-style pluggable connector RS-232 (Upstream Only) DCE, no handshaking; DB-9 connection; pin 2: transmitted data from display; pin 3: received data to display; pin 5: ground Terminal Block Torque 4.4 in-lb (0.5 N-m) Large LCD Report Slave ID 1" x 4" backlit LCD with adjustable brightness control for easy viewing Other Modbus devices must respond to the "Report Slave ID" command (11h) to allow passthrough communications from upstream network APPLICATIONS · Allocating load-based costs · Managing loads · Overload protection · Collecting energy data · Tenant submetering UI-SWITCH INPUTS Number/Function Four (METER, UP, DOWN, SELECT) AUXILIARY INPUT (REMOTE ALARM) Type Contact closure or pull-to-ground (10 mA max.) Isolation Optical to 2500 Vac Sense UI-selectable N.O. or N.C. (i.e. Closed = Alarm or Open = Alarm) Terminal Block Torque 3.5 to 4.4 in-lb (0.4 to 0.5 N-m) LCD Size 1" x 4" visible area, 2 lines x 16 characters per line Backlight Green, UI-adjustable brightness in 10 steps Status (Tri-Color LED) Green = normal operation; Yellow = warning; Red = alarm WARRANTY Limited Warranty 5 years 63 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NETWORK HOST MODE Application Example Control Panel or PC Network Integration | H8932 & H8936 On to additional Network Displays Upstream RS-485 or RS-232 Downstream RS-485 Up to 63 (physical) or 246 (logical) devices Network Display Next Network Display E2x Enercept Power Meter LOCAL DISPLAY MODE Application Example H8163 with H8163-CB Energy Meter with Communication Board E3x Panelboard Monitor E5xCx Power and Energy Meter Downstream RS-485 Up to 63 (physical) or 246 (logical) devices Network Display E2x Enercept Power Meter DIMENSIONAL DRAWING 8" (203 mm) H8163 with H8163-CB Energy Meter with C Bd 5.3" (133 mm) TM 8" (203 mm) 5.7" (146 mm) 4.2" (108 mm) E3x Panelboard Monitor E5xCx Power and Energy Meter ORDERING INFORMATION MODEL H8936 H8932 DESCRIPTION Modbus network display enclosed in NEMA box Modbus network display panel mount, no box 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 64 Network Integration | Modbus-to-BACnet Protocol Converter E8951 Integrate Multiple Modbus Meters into a BACnet Network BACnet, Modbus, SNMP Enables access to most Veris Modbus RTU meters via standard building automation protocols BACnet MS/TP, BACnet IP, Modbus TCP and SNMP* Extensive data collection Each E8951 can support over 10,000 BACnet measurement points (32 meters max.) Simultaneous Mixed meter E8951 support support Supports BACnet IP and Modbus TCP access simultaneously Simultaneously supports mixed meter types (with common baud rate)...versatility in the field The E8951 Modbus-to-BACnet Protocol Converter enables easy integration of a broad selection of Veris meters with Building Automation Systems via BACnet protocol. When networked, the E8951 detects supported Modbus meters and gives them a unique BACnet Device ID and full set of measurement data and configuration objects. Simply select the desired protocol settings using DIP switches and the integral web server, and the supported Veris Modbus meters are available as fully-supported BACnet devices. Application flexibility Supports a broad range of Veris meters: H8163 with H8163-CB, E2x, E50C2, E51C2, E50C3**, E51C3**, E30xxxx, E31xxxx, E34xxx and U013-0010/0011 I/O modules Easy setup Automatically detects supported meters and configures BACnet objects...no programming or manual mapping of Modbus points required SPECIFICATIONS DOWNSTREAM (DEVICE) INTERFACES Physical Layer 2-wire RS-485 Line Termination Internal, 120 Line Polarization Internal Protocol Modbus RTU Baud Rate 9600 to 38400 (selections vary with Modbus devices used) Number of Devices Supported BACnet mode - Up to 32 devices (10,000+ total BACnet data objects) SNMP mode - One 84-channel E30A/E31A or two 42-channel E30A per E8951 Modbus mode - 32 devices UPSTREAM (CONTROLLER) ETHERNET INTERFACE Physical Layer 10/100 Mb Ethernet Protocol BACnet IP, Modbus TCP, SNMP UPSTREAM (CONTROLLER) SERIAL INTERFACE Physical Layer 2-wire RS-485 Protocol BACnet MS/TP or Modbus RTU Baud Rate 9600, 19200, 38400, 76800 Parity Even, Odd or None (Modbus RTU only, BACnet MS/TP is always none) INPUT POWER REQUIREMENTS Supply Voltage Class 2; 9 to 30 Vdc or 12 to 24 Vac 50/60Hz Nominal Current Draw @ 12V 240 mA APPLICATIONS · Energy management systems · Building automation systems · Integrated metering of HVAC systems and chillers · SNMP access to E30A/E31A products in data centers* * Supports SNMP with a single E30A or E31A meter per E8951. ** The logging functionality of these meters is not supported. ENVIRONMENTAL Operating Temp Range Operating Humidity Range WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals UV Rheinlan ® B A C n e t · T Inc. · A TO R I E S TE S T ING d of Nor C th America, US LABOR -40 to 60 °C (-40 to 140 °F) 5 to 90% RH non-condensing; indoor use only 2 years CE; TUV approved to UL916; FCC Part 15 Class A; BTL 65 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING 2.9" (74 mm) 4.5" (115 mm) 5.1" (129 mm) 3.25" (83 mm) 3.6" (92 mm) 1.6" (41 mm) ORDERING INFORMATION MODEL DESCRIPTION E8951 Modbus-to-BACnet Protocol Converter Network Integration | E8951 APPLICATION EXAMPLE BACnet IP and Modbus TCP (or SNMP* AND Modbus TCP) (Ethernet) BACnet MS/TP or Modbus RTU (RS-485 Serial) E8951 Modbus to BACnet Protocol Converter Modbus RTU (RS-485 Serial) E2x Meter E5xCx Meter H8163 E34xxx Multi-Circuit Meter E30xxxx E31xxxx A8332-8F2D (U013-0011) A8911-23 (U013-0010) *Supports SNMP only with a single E30A or E31A meter per E8951. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 66 Network Integration | Serial-to-Ethernet Protocol Converter U013-0012, U013-0013 & U013-0015 Easy Translation of Protocols to Integrate into a Network U013-0012 U013-0013 Easy setup Requires no product-specific configuration DIN rail mount Easy installation Connect multiple devices Connect multiple devices to one network drop Wireshark® U013-0015 MS/TP slave devices are discoverable via automatic slave discovery and built-in MS/TP traffic capture using Wireshark with web page display* *Wireshark is an open source packet analyzer for network traffic available from wireshark.org. Wireshark is a registered trademark of the Wireshark Foundation. U013-0015 U013-0012 Modbus Gateway provides access to all Veris Modbus RTU products over a network using Modbus TCP protocol. U013-0013 and U013-0015 BACnet routers provide access to all Veris BACnet MS/TP products over a network using BACnet IP protocol. The U013-0015 (LX model) offers a faster operation speed and supports more BBMD entries. Integral web browsers enable quick and simple setup of network configuration and serial communication parameters. All three products provide easy translation of serial protocols to the corresponding network protocol without requiring any device-specific translation. SPECIFICATIONS U013-0012 DOWNSTREAM (DEVICE) INTERFACES Physical Layer 2-wire or 4-wire RS-485 Protocol Modbus RTU Baud Rate 50 to 921,600 UPSTREAM (CONTROLLER) ETHERNET INTERFACE Physical Layer 10/100 Mb Ethernet, Fixed IP or DHCP Protocol Modbus TCP INPUT POWER REQUIREMENTS Supply Voltage 12 to 48 Vdc Nominal Current 400 mA@12 Vdc, 130 mA@48 Vdc ENVIRONMENTAL Storage Temperature -40 to 85 °C (-40 to 185 °F) Operating Temperature 0 to 55 °C (32 to 131 °F) Relative Humidity 5 to 95% RH noncondensing; indoor use only WARRANTY Limited Warranty 5 years AGENCY APPROVALS Agency Approvals UL; CE; FCC Part 15 Class A; RoHS APPLICATIONS · Energy management systems · Building automation systems · Data center management SPECIFICATIONS U013-0013 & U013-0015 DOWNSTREAM (DEVICE) INTERFACES Physical Layer 2-wire RS-485 Protocol BACnet MS/TP Baud Rate U013-0013: 9600 to 78,600 U013-0015: 9600 to 115,200 UPSTREAM (CONTROLLER) ETHERNET INTERFACE Physical Layer 10/100 Mb Ethernet, Fixed IP Protocol BACnet IP BBMD Support U013-0013: 5 entries U013-0015: 50 entries INPUT POWER REQUIREMENTS Supply Voltage U013-0013: 24 Vdc±10%, 2 W; or 24 Vac ±10%, 4 VA, 50/60 Hz U013-0015: 24 Vdc±10%, 6 W; or 24 Vac ±10%, 10 VA, 50/60 Hz Frequency 47 to 63 Hz ENVIRONMENTAL Storage Temperature -40 to 85 °C (-40 to 185 °F) Operating Temperature 0 to 60 °C (32 to 140 °F) Relative Humidity 10 to 95% RH non-condensing WARRANTY Limited Warranty 2 years AGENCY APPROVALS Agency Approvals CE; FCC Part 15 Class A; RoHS 67 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Network Integration | U013-0012, U013-0013 & U013-0015 U013-0012 Application Example Modbus TCP Ethernet E2x Meter E5xCx Meter CWLP H8163 E3x Panelboard Monitoring System U013-0012 Modbus Gateway Modbus RTU (RS-485 Serial) U013-0013/U013-0015 Application Example BACnet IP Ethernet E5xCx Meter H8163 CWLP 380 Series BTU/Flow System 3xxx Series Flow Monitor U013-0013 BACnet Router BACnet MS/TP (RS-485 Serial) U013-0012 Dimensional Drawing 3.5" (89 mm) 1.1" (29 mm) 4.7" (119 mm) 4.9" (125 mm) U013-0013 Dimensional Drawing 0.3" (8 mm) 2.4" (62 mm) 0.6" (15 mm) 4.9" (123 mm) U013-0015 Dimensional Drawing 0.2" (6 mm) 2.6" (65 mm) 2.8" (80 mm) 1.0" (26 mm) 0.6" (15 mm) 5.2" (131 mm) 3.8" (96 mm) 1.6" (41 mm) ORDERING INFORMATION MODEL U013-0012 U013-0013 U013-0015 DESCRIPTION Modbus Gateway (RTU to TCP) BACnet Router (MS/TP to IP) BACnet Router (MS/TP to IP)-LX Model 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 68 Accessories: Power Monitoring ACCESSORIES SELECTION GUIDE: POWER MONITORING Single-Circuit Multi-Circuit Power CTs E20 FLEX E5x E5xxxA H8163 E30 E31 E34 AL, BL, CL & H681x-5A H681xV Page Product Description AE001 E3x MCB Cover, Veris Brand AE004 Replacement Mounting Clips for E5x AE006 E30 Solid-Core CT Repair Kit AE012 NEMA4X Enclosure for Single DIN Meter AE013 NEMA4X Enclosure for 4 DIN Meters AH02/03/04 Fuse Pack AH06 CT Mounting Bracket AH11 Bonding Kit for H81xx Series Meters AV01 35 mm DIN Rail - 1 Meter Long AV02 DIN Rail Stop Clip AV05 2.75 in Wide SnapTrack - 2 in Length CBLxxx Ribbon Cables for E3x Series E31CTDB Pair of E31 Adapter Boards with Mtg Kits E31CTx Split-Core branch CTs for E3x Series E681x Split-Core CTs with 1/3V Outputs E682x Split-Core CTs with 1/3V Outputs E683x Rogowski CTs for E20 Flex and E5xxxA E8951 Modbus-to Bacnet Protocol Converter H681x-5A Split-Core CTs with 5A Outputs H681x Split-Core CTs with 1/3V Outputs H8932/H8936 Remote Display (2-line LCD) U002-000x Shorting Blocks for Use with 5A CTs U013-0012 Modbus Gateway, RTU to TCP U013-0013 BACnet Router, MS/TP to IP U013-0015 BACnet Router LX, MS/TP to IP * For aux CT inputs (not branch CTs). · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 35 · 35 · 35 · · ·* ·* · 43 · ·* ·* · 43 · · 47 · · · · · · · 65 49 · · · ·* ·* · 41 · · · · · · 63 · · · · · · · · 67 · · · · 67 · · · 67 69 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Accessories | Power Monitoring AE001 E3x MCB Cover, Veris Brand AE006 E30 Solid-Core CT Repair Kit AE012, AE013, AE014 NEMA4X Enclosure for Single DIN Meter NEMA4X Enclosure for 4 DIN Meters AH02, AH03, AH04 AC Fuse Kits with Hi-interrupt Capability AH06 CT Mounting Brackets AV01 35 mm DIN Rail - 1 Meter Long AV02 DIN Rail Stop Clip AV05 2.75 in Wide SnapTrack, 2-in. Length (AV05) CBLXXX Ribbon Cables for E3x Series E31CT0, E31CT0, E31CT3 Split-Core branch CTs for E3x Series E681X Split-Core CTs with 1/3V Outputs E682X Split-Core CTs with 1/3V Outputs E683X Rogowski Rope Style CT E8951 H681X Modbus-to-Bacnet Protocol Converter Split-Core CTs with 1/3V Outputs H8932, H8936 Remote Display (2-line LCD) U002-000X Shorting Blocks for Use with 5A CTs U013-0012 Modbus Gateway, RTU to TCP U013-0013 BACnet Router, MS/TP to IP 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 70 AIR QUALITY/ GAS DETECTION Veris offers an extensive line of CO, CO2, VOC and NO2 sensors. Whether your application requires ventilation of a parking garage or an indoor venue, we have the perfect product for your needs. Comply with OSHA and ASHRAE 62.1 standards for air quality while saving energy by limiting runtime of exhaust fans and HVAC equipment. Ideal for Demand Control Ventilation (DCV) applications. MODEL CW2 CW2 Protocol CWE2 & CWV2 CD CDE CRLSXX GWN GWNP UG-7-A6O Uniguard GPS DESCRIPTION Analog Air Quality Sensors Protocol Air Quality Sensors Economy and Value Wall Mount CO2 Sensors Deluxe Duct & Wall CO2 Sensors Standard Duct and Wall CO2 Sensors Remote Mount CO2 Sensor with Field-Selectable Outputs Platform, CO/NO2 Gas Sensors Platform, CO/NO2 Gas Sensors, Protocol Communication Duct Mount Smoke Detector Ionization Systems and Sensors PAGE 73 75 77 79 81 83 85 87 89 91 AIR QUALITY SELECTION GUIDE CO2 SENSORS FEATURES Analog Output Field-Selectable Output Resistive Temperature Output Relay Output Protocol Output (BACnet and Modbus) Touchscreen or LCD Display with Humidity and Temperature Options GAS PLATFORM FEATURES Selectable Output 4 to 20 mA/0-5 or 0-10 Vdc Protocol Output (BACnet and Modbus) DUCT SMOKE SENSORS FEATURES Relay Output IONIZATION SYSTEMS AND SENSORS FEATURES Ionization Systems (Stand-alone) Ionization Systems (Analog Output) Wall Mount CW2, CWE2, CWV2 pages 73, 77 CW2, CWE2, CWV2 pages 73, 77 CW2, CWE2 pages 73, 77 CW2xP page 75 CW2L, CW2T page 73 Duct Mount CDL, CDE pages 79, 81 CDL, CDE pages 79, 81 CDL page 79 CDL page 79 CDL page 79 Remote Mount CRLSXX page 83 CO Sensors GWN page 85 GWNP page 87 NO2 Sensors GWN page 85 GWNP page 87 CO/NO2 Sensors GWNP page 87 Refrigerant Sensors GWN page 85 GWNP page 87 Wall Mount Duct Mount UG-7-A6O page 89 Remote Mount Wall Mount Duct Mount GPS-DM, GPS-FC,GPS-iRIB page 91 GPS-iMEASURE-D page 91 Remote Mount 71 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com CUT INSTALLATION COSTS GWN Series Gas Platform SIMPLE INSTALLATION, LOWER COSTS » Buy one base unit and install any of our six precision AG series sensors » Field-replaceable sensors save valuable installation and maintenance time MULTI-GAS CAPABILITIES » Measure CO and NO2 separately, combine CO/NO2, or measure refrigerant SEAMLESS SYSTEM INTEGRATION » Easy-to-use interface to control systems via BACnet or Modbus GWN/GWNP AGAE/AGPE CO AND NO2 SENSORS AG04 COMBINATION CO/NO2 SENSOR* No need to install multiple sensors to measure CO and NO2 APPLICATIONS: Parking Garages, Vehicle Bays *Compatible with protocol (BACnet MSTP/Modbus) units only AG04 AG01 CO 3% Accuracy AG01E CO 3% Accuracy REFRIGERANT SENSORS Get the best bang for your buck with AG05 and AG06 refrigerant sensors APPLICATIONS: Variable Refrigerant Flow, Mechanical Rooms, Occupied Spaces AG06 R410a AG05 R134a 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 72 Air Quality / Gas Detection | Analog Air Quality Sensors CW2 SERIES Individual or 4-in-1 CO2, VOC, RH & Temperature Microprocessor based Microprocessor controlled for excellent stability Easy to install Large wiring terminals on baseplate and snap-on covers with security screw simplify installation and service Self-calibrating Innovative self-calibration algorithm...easy to maintain Field selectable Field-selectable outputs for operation flexibility CW2Txxxx CW2Lxxxx CW2Xxxxx The CW2 Series of air quality sensors for living space is a flexible multi-sensor platform for use with BAS controllers designed to accept 4 to 20mA, 0 to 5Vdc or 0 to 10Vdc outputs. CW2 Series sensors are available with three user interface options: touchscreen, LCD with three buttons and blank. CO2 and temperature sensors are included with all CW2 Series air quality sensors. Models with VOC sensors and relative humidity sensors are also available. SPECIFICATIONS OPERATING ENVIRONMENT Input Power Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz Analog Output Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V Operating Temp. Range 0 to 50 °C (32 to 122 °F) Operating Humidity Range 0 to 95% RH non-condensing Housing Material High-impact ABS plastic Terminal Block Torque 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) CO2 TRANSMITTER Sensor Type Non-dispersive infrared (NDIR), diffusion sampling Output Range 0 to 2000/5000 ppm (selectable) Accuracy ±30 ppm ±3% of measured value Repeatability ±20 ppm ±1% of measured value Response Time <60 seconds for 90% step change VOC TRANSMITTER OPTION Sensor Type Solid state Output Range 0 to 100% AQI for VOC Accuracy ±15% of measured value Output Scale 0 to 1,000 ppb of total VOC (TVOC) LEVEL VENTILATION RECOMMENDATION TVOC (ppb) >61% Greatly increased >610 20 to 61% Significantly increased 200 to 610 AQI Table* 10 to 20% Slightly increased 100 to 200 5 to 10% Average 50 to 100 0 to 5% Target value 0 to 50 Dual-beam NDIR CO2 sensor Dual-beam, non-dispersive infrared technology (NDIR) repeatable to ±20 ppm ±1% of measured value...high accuracy measurement APPLICATIONS · Controlling ventilation in response to accuracy · ASHRAE 62.1 compliant Multi-sensor platform CO2, VOC, RH and temp in one device...lower installation and service costs · Office buildings, conference rooms, schools, retail stores, etc. RH TRANSMITTER OPTION HS Sensor Thin-film capacitive, replaceable Accuracy ±2% from 10 to 80% RH @ 25 °C (77 °F) Hysteresis 1.5% typical Stability ±1% @ 20°C (68 °F) annually for 2 years Output Range 0 to 100% RH Temperature Coefficient ±0.1% RH/°C above or below 25 °C (77 °F) typical TEMPERATURE TRANSMITTER OPTION Sensor Type Solid state, integrated circuit Accuracy ±0.2 °C (±0.4 °F) typical Resolution 0.1 °C (0.1 °F) Range 0 to 50 °C (32 to 122 °F) DISPLAY MODELS Touchscreen 61 mm (2.4 in), color, backlit, capacitive, 240x300 px Setpoint: 0-10Vdc. Temperature, humidity or fan speed selectable Timeout override: Display timeout** Lockout override: Touchscreen/button lockout** 52mm (2.05 in), segmented with 3 buttons Setpoint: 0-10Vdc. Temperature, humidity or fan speed LCD selectable Timeout override: Display timeout** Lockout override: Touchscreen/button lockout** SETPOINTS*** Temperature Setpoint 0 to 10V output Scale: 10 to 35 °C (50 to 95 °F) / 0 to 50 °C (32 to 122 °F) Humidity Setpoint 0 to 10V output Scale: 0 to 100% RH 73 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Air Quality / Gas Detection | CW2 Series SPECIFICATIONS (CONT.) Fan Speed Setpoint 0 to 10V output Off 0V, Low 3.3V, Med. 6.7V, High 10.0V OVERRIDE Override Button Display models feature momentary-to-ground override button WIRING TERMINALS Terminal Blocks Screw terminals, 18-24 AWG Screw Terminal Torque 0.2 N-m (2.0 in-lbF) max. WARRANTY Limited Warranty 5 years COMPLIANCE INFORMATION Agency Approvals UL 916, European conformance CE: EN61000-6-2, EN61000-6-3, EN61000 Series - industrial immunity, EN 61326-1 FCC Part 15 Class B, REACH, RoHS, RCM (Australia), ICES-003 (Canada) * Air Quality Index for VOC aligns with TVOC levels for IAQ as specified by the WHO (World Health Organization). **DIP switch selectable. *** One setpoint type is selectable via DIP switch on display models only. DIMENSIONAL DRAWING 115 (4.5) 85 (3.3) USER INTERFACE TYPES Touchscreen LCD with Buttons 24 (0.9) Blank CW2L/CW2T DISPLAY MODELS WITH TEMP TRANSMITTER Wiring Diagram VOC OUT CO2 OUT OVERRIDE SETPOINT OUT RH OUT TEMP OUT COMMON POWER (+24) 10 9 8 7 6 5432 1 CW2X WITH TEMP TRANSMITTER Wiring Diagram VOC OUT CO2 OUT RH OUT TEMP OUT COMMON POWER (+24) 10 9 8 7 6 5432 1 CW2L/CW2T DISPLAY MODELS WITH RTD/THERMISTOR Wiring Diagram VOC OUT CO2 OUT OVERRIDE SETPOINT OUT RH OUT RTD/THERMISTOR OUT RTD/THERMISTOR OUT COMMON POWER (+24) 10 9 8 7 6 5432 1 CW2X WITH RTD/THERMISTOR Wiring Diagram VOC OUT CO2 OUT RH OUT RTD/THERMISTOR OUT RTD/THERMISTOR OUT COMMON POWER (+24) 10 9 8 7 6 5432 1 Optional Optional Optional Optional Optional Optional Optional Optional ORDERING INFORMATION CW2 User Interface Output T = Color touchscreen L = 3-button LCD display X = None*** A = Analog output RH Accuracy* 2 = 2% X = None*** Temperature A = Transmitter C = 1000 PT RTD D = 10K T2 thermistor H = 10K T3 thermistor K = 10K curve G/11K shunt M = 20K NTC thermistor N = 1.8K TAC thermistor VOC Sensor V = NDIR CO2 / VOC** = None Example: CW2 T A 2 A V * Replaceable 1% with NIST certificate, 2% with NIST certificate and 2% elements available. ** VOC only availble with temperature transmitter option *** For analog non-display, non-RH, models with RTD/thermistor order from CWE2 line. REPLACEABLE RH ELEMENTS MODEL HS1N HS2N HS2X RH ACCURACY ±1% ±2% ±2% CALIBRATION CERTIFICATE X X DESCRIPTION Replaceable RH sensor, 1% with NIST certification Replaceable RH sensor, 2% with NIST certification Replaceable RH sensor, 2% Replaceable RH Element ACCESSORIES P. 93 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 74 Air Quality / Gas Detection | Protocol Air Quality Sensors CW2 PROTOCOL SERIES Individual or 4-in-1 CO2, VOC, RH & Temperature CW2Txxxx CW2Lxxxx CW2Xxxxx The CW2 Protocol Series of air quality sensors for living space is a flexible multi-sensor platform for use with BAS controllers designed to accept BACnet or Modbus outputs. CW2 Protocol Series sensors are available with three user interface options: touchscreen, LCD with three buttons and blank. CO2 and temperature sensors are included with all CW2 Protocol Series air quality sensors. Models with VOC sensors and relative humidity sensors are also available. SPECIFICATIONS OPERATING ENVIRONMENT Input Power Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz Protocol Output BACnet or Modbus via RS-485, selectable Operating Temp. Range 0 to 50 °C (32 to 122 °F) Operating Humidity Range 0 to 95% RH non-condensing Housing Material High-impact ABS plastic Terminal Block Torque 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) CO2 TRANSMITTER Sensor Type Non-dispersive infrared (NDIR), diffusion sampling Output Range 0 to 2000/5000 ppm (selectable) Accuracy ±30 ppm ±3% of measured value Repeatability ±20 ppm ±1% of measured value Response Time <60 seconds for 90% step change VOC TRANSMITTER OPTION Sensor Type Solid state Output Range 0 to 100% AQI for VOC Accuracy ±15% of measured value Output Scale 0 to 1,000 ppb of total VOC (TVOC) LEVEL VENTILATION RECOMMENDATION TVOC (ppb) >61% Greatly increased >610 20 to 61% Significantly increased 200 to 610 AQI Table* 10 to 20% Slightly increased 100 to 200 5 to 10% Average 50 to 100 0 to 5% Target value 0 to 50 Communicating Embedded BACnet and Modbus communication protocols...easy systems integration Self-calibrating Innovative self-calibration algorithm...easy to maintain Dual-beam NDIR CO2 sensor Dual-beam, non-dispersive infrared technology (NDIR) repeatable to ±20 ppm ±1% of measured value...high accuracy measurement APPLICATIONS · Controlling ventilation in response to accuracy · ASHRAE 62.1 compliant Configurable baud rates Configurable to multiple baud rates...transfer data at the right speed for the system Easy to install Large wiring terminals on baseplate and snap-on covers with security screw simplify installation and service Multi-sensor platform CO2, VOC, RH and temp in one device...lower installation and service costs · Office buildings, conference rooms, schools, retail stores, etc. RH TRANSMITTER OPTION HS Sensor Thin-film capacitive, replaceable Accuracy ±2% from 10 to 80% RH @ 25°C (77 °F) Hysteresis 1.5% typical Stability ±1% @ 20°C (68 °F) annually for 2 years Output Range 0 to 100% RH Temperature Coefficient ±0.1% RH/°C above or below 25 °C (77 °F) typical TEMPERATURE TRANSMITTER Sensor Type Solid state, integrated circuit Accuracy ±0.2 °C (±0.4 °F) typical Resolution 0.1 °C (0.1 °F) Range 0 to 50 °C (32 to 122 °F) DISPLAY MODELS Touchscreen 61 mm (2.4 in), color, backlit, capacitive, 240x300 px Setpoint: Temperature, humidity or fan speed selectable Timeout override: Display timeout Lockout override: Touchscreen/button lockout 52mm (2.05 in), segmented with 3 buttons LCD Setpoint: Temperature, humidity or fan speed selectable Timeout override: Display timeout Lockout override: Touchscreen/button lockout SETPOINTS Temperature Setpoint Scale: 10 to 35 °C (50 to 95 °F) / 0 to 50 °C (32 to 122 °F) Humidity Setpoint Scale: 0 to 100% RH Fan Speed Setpoint Off, Low, Medium, High 75 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Air Quality / Gas Detection | CW2 Protocol Series SPECIFICATIONS (CONT.) OVERRIDE Override Button Display models feature momentary override button WIRING TERMINALS Terminal Blocks Screw terminals, 18-24 AWG Screw Terminal Torque 0.2 N-m (2.0 in-lbF) max. WARRANTY Limited Warranty 5 years COMPLIANCE INFORMATION Agency Approvals UL 916, European conformance CE: EN61000-6-2 EN61000-6-3 EN61000 Series - industrial immunity EN 61326-1 FCC Part 15 Class B, REACH, RoHS, RCM (Australia), ICES-003 (Canada) * Air Quality Index for VOC aligns with TVOC levels for IAQ as specified by the WHO (World Health Organization) USER INTERFACE TYPES Touchscreen LCD with Buttons DIMENSIONAL DRAWING WIRING DIAGRAM Blank 115 (4.5) 85 24 (3.3) (0.9) ORDERING INFORMATION CW2 User Interface Output RH Accuracy* T = Color touchscreen L = 3-button LCD display X = None*** P = BACnet/Modbus 2 = 2% X = None VOC Sensor A V = NDIR CO2 / VOC = None * Replaceable 1% with NIST certificate, 2% with NIST certificate and 2% elements available. RS-485 (+) RS-485 (-) GROUND POWER (+24) 5432 1 Example: CW2 T P 2 A V REPLACEABLE RH ELEMENTS MODEL HS1N HS2N HS2X RH ACCURACY ±1% ±2% ±2% CALIBRATION CERTIFICATE X X DESCRIPTION Replaceable RH sensor, 1% with NIST certification Replaceable RH sensor, 2% with NIST certification Replaceable RH sensor, 2% Replaceable RH Element ACCESSORIES P. 93 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 76 Air Quality / Gas Detection | Analog Air Quality Sensors CWE2 & CWV2 SERIES Economy and Value Wall Mount CO2 Sensors 2-Wire 4-20 mA Output CWE2 models offer 2-wire current outputs...lower installation costs Economy Sensor Competitively-priced sensors ideal for bid-spec Easy to install Self-calibrating Large wiring terminals on baseplate and snap-on covers with security screw simplify installation and service Innovative self-calibration algorithm...easy to maintain Field selectable The CWE2 and CWV2 Series of air quality sensors for living space are for use with BAS controllers designed to accept 4 to 20mA, 0 to 5 Vdc or 0 to 10 Vdc outputs. These sensors measure CO2 levels using a dual-beam, non-dispersive infrared (NDIR) technology. The CWE2 Series Economy sensor has an accuracy of ±30 ppm ±3% of measured value, features 2-wire 4 to 20mA and 3-wire voltage outputs, and is available with optional temperature output. The CWV2 Value sensor with an accuracy of ±40 ppm ±5.5% of measured value, is ideal for bid-spec applications. Field-selectable outputs for operation flexibility APPLICATIONS · Controlling ventilation in response to occupancy · Office buildings, conference rooms, schools, retail stores, etc. · Facilitating compliance with ASHRAE 62.1 standard for air quality SPECIFICATIONS OPERATING ENVIRONMENT Input Power Max. Current Analog Output Operating Temperature Range Operating Humidity Range Housing material Terminal Block Torque CO2 TRANSMITTER Sensor Type Output Range Accuracy Repeatability Response Time Startup Time Max. Load Resistance* WIRING TERMINALS Terminal Blocks Screw Terminal Torque WARRANTY Limited Warranty Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz CWE2: 20 mA CWV2: 45 mA Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V 0 to 50 °C (32 to 122 °F) 0 to 95% RH non-condensing High-impact ABS plastic 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) Dual-beam, non-dispersive infrared (NDIR), diffusion sampling 0 to 2000 ppm CWE2: ±30 ppm ±3% of measured value CWV2: ±40 ppm ±5.5% of measured value CWE2: ±20 ppm ±1% of measured value CWV2: ±30 ppm ±4.5% of measured value 75 seconds for 90 degree step change CWE2: 20 seconds CWE2: 100 at 20 Vdc 250 at 24 Vdc 500 at 30 Vdc Screw terminals, 18-24 AWG 0.2 N-m (2.0 in-lbF) max. CWE2: 3 years CWV2: 1 year COMPLIANCE INFORMATION Agency Approvals UL 916, European conformance CE: EN61000-6-2 EN61000-6-3 EN61000 Series - industrial immunity EN 61326-1 FCC Part 15 Class B, REACH, RoHS, RCM (Australia), ICES-003 (Canada) *Applicable for CWE2 4-20 mA current mode only. If load parameters are not met, product will reset. 77 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING 115 (4.5) 85 (3.3) CWV2 Wiring Diagram Air Quality / Gas Detection | CWE2 & CWV2 Series CWE2 VOLTAGE OUTPUT Wiring Diagram CO2 OUT RTD/THERMISTOR OUT RTD/THERMISTOR OUT COMMON POWER (+24) 5432 1 24 (0.9) Optional CWE2 CURRENT OUTPUT Wiring Diagram CO2 OUT COMMON POWER (+24) 5432 1 ORDERING INFORMATION Temperature Option CWE2 Blank = None C = 1000 PT RTD D = 10K T2 thermistor H = 10K T3 thermistor K = 10K curve G/11K shunt M = 20K NTC thermistor N = 1.8K TAC thermistor Example: CWE2 C CWV2 (No Options) RTD/THERMISTOR OUT RTD/THERMISTOR OUT CO2 mA RETURN POWER (+24) 5432 1 Optional 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 93 78 Air Quality / Gas Detection | Deluxe Duct & Wall CO2 Sensors CD SERIES Individual or 3-in-1 CO2, RH and Temperature Microprocessor based Microprocessor-based design increases accuracy and reduces installation time Snap-on faceplate Snap-on faceplate...no screws required, making installation and service easy CDL CDL carbon dioxide (CO2) sensors maximize energy savings, while helping optimize ventilation. These sensors allow ventilation systems to be controlled by the amount of CO2 present in a space. The CDL Series detect fluctuations in CO2 levels and signal ventilation systems to provide an inlet of fresh air optimal for the space at a given time saving energy and increasing tenant comfort. Self-calibrating Innovative self-calibration algorithm...easy to maintain NDIR Non-dispersive infrared technology (NDIR) repeatable to ±20 ppm ±1% of measured value...high accuracy measurement Field-selectable Field-selectable outputs for operation flexibility Integrated probe Integrated transducer and probe...eliminates the need to install a separate pick-up tube SPECIFICATIONS Input Power Class 2; 20 to 30 Vdc/24 Vac 50/60 Hz; 100 mA max. Analog Output 4 to 20 mA (clipped and capped)/0 to 5 Vdc/ 0 to 10 Vdc (selectable) Operating Temp Range 0 to 50 °C (32 to 122 °F) Operating Humidity Range 0 to 95% RH non-condensing Housing Material High impact ABS plastic Terminal Block Torque 0.2 N-m (2.0 in-lbf ) max. Terminal Block Wire Size 28 to 14 AWG (0.5 to 1.5mm2) CO2 TRANSMITTER Sensor Type Non-dispersive infrared (NDIR), diffusion sampling Output Range 0 to 2000/5000 ppm (programmable) Accuracy ±30 ppm ±2% of measured value* Repeatability ±20 ppm ±1% of measured value Response Time <60 seconds for 90% step change RH TRANSMITTER OPTION HS Sensor Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 Accuracy ±2% from 10 to 80% RH @ 25 °C; NIST traceable multi-point calibration Hysteresis 1.5% typical Stability ±1% @ 20 °C (68 °F) annually for two years Output Range 0 to 100% RH Temperature Coefficient ±0.1% RH/°C above or below 25 °C (typical) TEMPERATURE TRANSMITTER OPTION Sensor Type Solid-state, integrated circuit Accuracy ±0.5 °C (±1 °F) typical Resolution 0.1 °C (0.2 °F) Output Range 10 to 35°C (50 to 95°F) APPLICATIONS · Controlling ventilation in response to occupancy · ASHRAE 62.1 air quality standard compliance RELAY CONTACTS 1 Form C (SPDT) WARRANTY Limited Warranty AGENCY APPROVALS 1 A@30 Vdc, resistive; 30 W max. 5 years RTD/Thermistors in wall packages are not compensated for internal heating of product. EMC Conformance: Low voltage directive 2014/35/EU and EMC directive 2014/30/EU. EMC Special Note: Connect this product to a DC distribution network or an AC DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). * Measured at NTP. Note: Rough handling and transportation may cause a temporary reduction of CO2 sensor accuracy. With time, the ABC function will tune the readings back to the correct accuracy range. The default tuning speed is limited to 30 ppm per week. 79 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com CDL (CO2 ONLY) Wiring Diagram PLUS CONFIGURATION ENTER PUSHBUTTONS MINUS mA Volt ABC ON V+ CO2-OUT GND LOW OFF NC COMM NO 1/2" NPT MALE CONDUIT ADAPTER 1/2" NPT FEMALE COUPLER Air Quality / Gas Detection | CD Series CDL (TEMP AND/OR RH OPTIONS) Wiring Diagram PLUS CONFIGURATION ENTER PUSHBUTTONS MINUS V+CO2 RH OUT GND OUT TEMP OUT/RTD RTD NC COMM NO mA Volt CDL Dimensional Drawing 6.7" (170 mm) 3.1" (78 mm) 2.4" (61 mm) 10.2" (258 mm) 7.8" (198 mm) ORDERING INFORMATION RH Option Temp Sensor Type Optional Cal Cert CDLS H = RH2% T = Temp A = Transmitter Blank = None X = No RH X = No Temp B = 100R Platinum, RTD 1 = 1 pt Temp Cert* (Stop here) C = 1k Platinum, RTD 2 = 2 pt Temp Cert* D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor G = 10k CPC, Thermistor H = 10k T3, Thermistor J = 10k Dale, Thermistor K = 10k w/11k shunt, Thermistor M = 20k NTC, Thermistor Example: N = 1800 ohm, Thermistor R = 10k US, Thermistor CDLS H T B 2 S = 10k 3A221, Thermistor T = 100k, Thermistor U = 20k "D", Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor *Not available with W and Y high accuracy thermistors. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 93 80 Air Quality / Gas Detection | Standard Duct and Wall CO2 Sensors CDE Field-selectable 4 to 20 mA / 0 to 10 Vdc Output NDIR Non-dispersive infrared technology (NDIR) repeatable to ±20 ppm ±1% of measured value... high accuracy measurements 4 to 20 mA/ 0 to 10 Vdc 4 to 20 mA/0 to 10 Vdc output for flexible control system interface Sensitivity Low ambient sensitivity CDE CDE is a non-dispersive infrared (NDIR) sensor designed for measuring environmental CO2 concentration in ventilation systems. With a measurement range of 0 to 2000 ppm, the CDE sensor is compliant with ASHRAE and other standards for ventilation control CDE provides a user-selectable 4 to 20 mA or 0 to 10 Vdc output for versatility. Microprocessor-based digital electronics and a unique selfcalibration algorithm improves long-term stability and accuracy. Bid-spec Idea for bid spec applications where low cost is key factor Self-calibrating Innovative self-calibration algorithm...easy to maintain. 5-year calibration interval (recommended) SPECIFICATIONS Input Power Class 2; 20 to 30 Vdc/24 AC 50/60 Hz; 100 mA max. Analog Output 4 to 20 mA (clipped & capped)/0 to 10 Vdc (selectable) Operating Temp. Range 0 to 50 °C (32 to 122 °F) Operating Humidity Range 0 to 95% RH non-condensing Housing Material High impact ABS plastic Terminal Block Torque: 0.5 to 0.6 N-m (4.4 to 5.3 in-lbf ) max. Terminal Block Wire Size: 24 to 12 AWG (0.25 to 2.5mm2) Sensor Type Non-dispersive infrared, diffusion sampling Output Range 0 to 2000 ppm Accuracy ±30 ppm ±2% of measured value* Repeatability ±20 ppm ±1% of measured value Response Time <60 seconds for 90% step change WARRANTY Limited Warranty 3 years AGENCY APPROVALS APPLICATIONS · Controlling ventilation in response to occupancy · Facilitating compliance with ASHRAE 62.1 standard for air quality EMC Conformance: Low voltage directive 2014/35/EU and EMC directive 2014/30/EU. EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). * Measured at NTP Note: Rough handling and transportation may cause a temporary reduction of CO2 sensor accuracy. With time, the ABC function will tune the readings back to the correct accuracy range. The default tuning speed is limited to 30 ppm per week. 81 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com CDE Dimensional Drawing 6.7" (170 mm) 3.1" (78 mm) 10.2" (258 mm) CDE Wiring Diagram Calibration Pushbutton LED mA Volt V+ CO2-OUT GND 2.4" (61 mm) 7.8" (198 mm) mA/Volt Selection Switch ABC Jumper Conduit Adapter 1/2" NPT male/female ORDERING INFORMATION MODEL DESCRIPTION CDE Economy duct CO2 sensor Air Quality / Gas Detection | CDE 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 93 82 Air Quality / Gas Detection | Remote Mount CO2 Sensor with Field-Selectable Outputs CRLSXX Suitable for Outside Air Measurement Applications CRL NDIR Non-dispersive infrared technology (NDIR) repeatable to ±20 ppm ±1% of measured value...high accuracy Sensitivity Low ambient sensitivity Microprocessor based Microprocessor-based design reduces long-term drift and calibration requirements Self-calibrating Innovative self-calibration algorithm...easy to maintain. 5-year calibration interval (recommended) LCD LCD display for visibility Field-selectable Field-selectable 4 to 20 mA/0 to 5 V/0 to 10 V output for system flexibility The CRLSXX remote mount carbon dioxide sensor is designed for use in HVAC control applications. Inside buildings, people are the major source of CO2. By controlling fresh air based on CO2 levels, energy can be saved and tenant comfort improved. The remote capability of the CRLSXX provides flexibility for unique applications. APPLICATIONS · Controlling HVAC in response to occupancy · Improving tenant comfort · Facilitating compliance with ASHRAE 62.1 standard for air quality · Direct measuring of outside air or sample from other remote area SPECIFICATIONS Input Power Analog Output Operating Temp Range* Operating Humidity Range Housing Material Terminal Block Torque Terminal Block Wire Size CO2 TRANSMITTER Sensor Type Output Range Accuracy** Class 2; 20 to 30 Vdc/24 Vac 50/60 Hz; 100 mA maximum 4 to 20mA (clipped & capped)/0 to 5 Vdc/ 0 to 10 Vdc (selectable) 0 to 50 °C (32 to 122 °F) 0 to 95% RH non-condensing High impact ABS plastic 0.5 to 0.6 N-m (4.4 to 5.3 in-lbf ) max. 24 to 12 AWG (0.25 to 2.5mm2) Non-dispersive infrared (NDIR), diffusion sampling 0 to 2000/5000 ppm (programmable) ±30 ppm ±2% of measured value Repeatability Response Time*** WARRANTY Limited Warranty AGENCY APPROVALS ±20 ppm ±1% of measured value <60 seconds for 90% step change 5 years EMC Conformance: Low voltage directive 2014/35/EU and EMC directive 2014/30/EU. EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). *When directly measuring outside air, ensure the temperature of the air as it reaches the sensor is between 0 and 50 °C. **Measured at NTP ***Response time when used with 3ft long sampling tube, Veris part number AA50. Note: Rough handling and transportation may cause a temporary reduction of CO2 sensor accuracy. With time, the ABC function will tune the readings back to the correct accuracy range. The default tuning speed is limited to 30 ppm per week. 83 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com WIRING DIAGRAM CONFIGURATION PUSHBUTTONS PLUS ENTER MINUS mA Volt ABC ON V+ CO2-OUT GND LOW OFF NC COMM NO ORDERING INFORMATION MODEL DESCRIPTION CRLSXX Remote mount CO2 sensor. Air Quality / Gas Detection | CRLSXX DIMENSIONAL DRAWING 170 mm (6.7") 78 mm (3.1") 61 mm (2.4") 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 93 84 Air Quality / Gas Detection | Platform for Gas Sensors GWN Modular Gas Sensor Platform Accepts AG Series Gas Sensors Modular design Modular platform accepts Veris AG Series sensors (sold separately)...no need to install a new GWNP when the sensor life wears out Wide options Interface to control system via 4 to 20 mA with relay, 0 to 5 / 0 to 10 Vdc with relay, or relay only options...application flexibility LEDs No calibration Three colored LEDs - red, yellow No calibration required...easy and green - for easy status viewing maintenance and worry-free GWN AGAE Enclosure (sold separately) GWN Series platform offers a convenient means for sensing gases in the environment. The GWN is mounted to any single-gang electrical box and wired to the building controller. Then, a single AGxx gas sensor (sold separately) is installed in the GWN. With this design, there is no need for a costly new installation when a sensor reaches the end of its life. The GWN platform remains installed, and the installer simply opens the GWN housing to replace the modular sensor inside, reducing labor costs and downtime. AG Series sensors can be swapped in the GWN platform at any time with minimal effort. The GWN platform converts the signal from the AG sensor into an analog or relay signal compatible with building control systems. The available AGAE metal enclosure (sold separately) provides a modular solution for applications that require a rugged enclosure along with an integral audible horn and 10 A relay for direct fan control. Microprocessor based Microprocessor controlled... excellent stability operation APPLICATIONS · Parking garage ventilation · Air quality compliance · Vehicle bays (ambulance/fire/taxi) Versatile interface Interface to DDC systems or direct fan control · Mechanical rooms · Sally ports SPECIFICATIONS Input Power 15 to 30 Vdc/24 Vac ±20%, Class 2, 50/60Hz, max. 60 mA Relay Ratings 1A/30 Vac/dc, normally open Operating Temperature Range -20 to 50 °C (-4 to 122 °F) Operating Humidity Range 0 to 90% RH non-condensing Terminal Block Wire Size 30 to 12 AWG Terminal Block Torque 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) Protection Class (self-evaluated) IP20 WARRANTY Limited Warranty 5 years* COMPLIANCE INFORMATION Agency Approvals Intertek ETL Listed to UL 61010-1 The GWN operates only when an AG Series gas sensor is installed (sold separately). Accuracy, sensitivity, setpoints, and measurement range are dependant on the AG Series sensor connected to the GWN platform. See the AG Series sensor installation guide for details. * The AG Series gas sensors are warranted for two years from the date of manufacture. The AG Series sensors are not included in the five-year GWN warranty. 85 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Air Quality / Gas Detection | GWN AG01 CO Sensor SENSOR TYPE Electrochemical MEASUREMENT RANGE 0 to 300 ppm ACCURACY ±3% of range ANALOG OUTPUT SCALING RESOLUTION SENSOR WARRANTY LOW SETPOINT VALUE HIGH SETPOINT VALUE OPERATING TEMP. RANGE OPERATING HUMIDITY RANGE 0 to 200 ppm 1 ppm 2 years from manufacture date 25 or 35 ppm (switch selectable) 180 ppm (fixed) -20 to 50 °C (-4 to 122 °F) 0 to 90% RH non-condensing DIMENSIONAL DRAWING 0.6" (15 mm) 4.5" (113 mm) AG01E CO Sensor Electrochemical 0 to 500 ppm ±5% of range AG02 NO2 Sensor Electrochemical 0 to 15 ppm ±5% of range at 25 °C 0 to 200 ppm 0 to 15 ppm 1 ppm 0.1 ppm 1 year from manufacture 2 years from date manufacture date 25 or 35 ppm (switch selectable) 1 ppm (fixed) 180 ppm (fixed) 3 ppm (fixed) -20 to 50 °C (-4 to 122 °F) -20 to 50 °C (-4 to 122 °F) 0 to 90% RH non-condensing 0 to 90% RH non-condensing AG05 R134a Refrigerant Sensor Non-dispersive infrared 0 to 2000 ppm ±2% of range (60 to 2000 ppm) 0 to 2000 ppm AG06 R410a Refrigerant Sensor Non-dispersive infrared 0 to 2000 ppm ±2% of range (60 to 2000 ppm) 0 to 2000 ppm 1 ppm 2 years from manufacture date 100 ppm (fixed) 1 ppm 2 years from manufacture date 100 ppm (fixed) 500 ppm (fixed) -20 to 50 °C (-4 to 122 °F) 0 to 90% RH non-condensing 500 ppm (fixed) -20 to 50 °C (-4 to 122 °F) 0 to 90% RH non-condensing 3.25" (83 mm) ORDERING INFORMATION - PLATFORM Output GWN* X X Housing Color V = Field-selectable, 0-5/0-10 Vdc with relay M = 4 to 20 mA with relay 1 = Relay only Blank = Black W = White Example: GWN M X X W 2.75" (70 mm) WIRING DIAGRAM 1.2" 1.1" (30 mm) (27 mm) Power Supply + Control System Common Gas Sensor Input* Relay Common High Setpoint End of Life Low Setpoint * Not available on relay only models. 1.7" (42 mm) *The GWN will not operate without an AG Series sensor installed. Sensors are sold separately. ORDERING INFORMATION REQUIRED SENSORS MODEL DESCRIPTION AG01 CO sensor, 3% accuracy. CO sources include exhaust from gasoline powered engines, furnaces, water heaters and generators. AG01E CO sensor, 5% accuracy. CO sources include exhaust from gasoline engines, furnaces, water heaters and generators AG02 NO2 sensor. NO2 sources include exhaust from diesel powered engines and generators. AG05 R134a sensor. R134a is a refrigerant used in HVAC applications. AG06 R410a sensor. R410a is a refrigerant used in HVAC applications. Note: See Specifications section for AG sensor warranty details. ORDERING INFORMATION ACCESSORY ENCLOSURE MODEL AGAE DESCRIPTION Metal wall mount enclosure for the GWN gas platform with audible horn and 10 A relay ACCESSORIES P. 93 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 86 Air Quality / Gas Detection | Platform for Gas Sensors, Protocol Communication GWNP Modular Gas Sensor Platform Accepts AG Series Gas Sensors Communication Interface to control system via BACnet and Modbus protocols. BTL certified. Microprocessor based Microprocessor controlled for excellent stability Modular platform No calibration Modular platform accepts Veris AG Series sensors (sold separately)... no need to install a new GWNP when the sensor life wears out No calibration required...easy maintenance and worry-free operation LEDs Versatile GWNP AGPE Enclosure (sold separately) Three colored LEDs - red, yellow and green - for easy status viewing interface Interface to DDC systems or direct fan control GWNP Series protocol communications platform offers a convenient means for sensing gases in the environment. The GWNP is mounted to any single-gang electrical box and wired to the building controller. Then, a single AGxx gas sensor (sold separately) is installed in the GWNP. With this design, there is no need for a costly new installation when a sensor reaches the end of its life. The GWNP platform remains installed, and the installer simply opens the GWNP housing to replace the modular sensor inside, reducing labor costs and downtime. AG Series sensors can be swapped in the GWNP platform at any time with minimal effort. The GWNP platform converts the signal from the AG sensor into protocol communications compatible with building control systems. The available AGPE metal enclosure (sold separately) provides a modular solution for applications that require a rugged enclosure along with an integral audible horn and 10 A relay for direct fan control. APPLICATIONS · Parking garage ventilation · Air quality compliance · Vehicle bays (ambulance/fire/taxi) · Mechanical rooms · Sally ports SPECIFICATIONS Input Power Relay Ratings Operating Temperature Range Operating Humidity Range Terminal Block Wire Size Protocol Terminal Block Torque Protection Class (self-evaluated) WARRANTY Limited Warranty COMPLIANCE INFORMATION Agency Approvals 15 to 30 Vdc/24 Vac ±20%, Class 2, 50/60Hz, max. 60 mA 1A/30 Vac/dc, normally open -20 to 50 °C (-4 to 122 °F) 0 to 90% RH non-condensing 30 to 12 AWG BACnet and Modbus (selectable) 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) IP20 5 years* Intertek ETL Listed to UL 61010-1 The GWNP operates only when an AG Series gas sensor is installed (sold separately). Accuracy, sensitivity, setpoints, and measurement range are dependant on the AG Series sensor connected to the GWNP platform. See the AG Series sensor installation guide for details. * The AG Series gas sensors are warranted for two years from the date of manufacture. The AG Series sensors are not included in the five-year GWNP warranty. 87 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Air Quality / Gas Detection | GWNP SENSOR TYPE MEASUREMENT RANGE ACCURACY OUTPUT SCALING AG01 CO Sensor Electrochemical 0 to 300 ppm ±3% of range 0 to 200 ppm AG01E CO Sensor Electrochemical 0 to 500 ppm ±5% of range 0 to 200 ppm AG02 NO2 Sensor Electrochemical 0 to 15 ppm ±5% of range at 25 °C 0 to 15 ppm AG04* CO & NO2 Sensor CO: Electrochemical NO2: Electrochemical CO: 0 to 500 ppm NO2: 0 to 20 ppm CO: ±5% of range NO2: ±5% of range N/A AG05 AG06 R134a Refrigerant Sensor R410a Refrigerant Sensor Non-dispersive infrared Non-dispersive infrared 0 to 2000 ppm 0 to 2000 ppm ±2% of range (60 to 2000 ppm) 0 to 2000 ppm ±2% of range (60 to 2000 ppm) 0 to 2000 ppm RESOLUTION SENSOR WARRANTY 1 ppm 2 years from manufacture date 1 ppm 1 year from manufacture date 0.1 ppm 2 years from manufacture date CO: 1 ppm NO2: 0.1 ppm 2 years from manufacture date 1 ppm 2 years from manufacture date 1 ppm 2 years from manufacture date LOW SETPOINT VALUE HIGH SETPOINT VALUE OPERATING TEMP. RANGE 25 or 35 ppm (switch selectable) 180 ppm (fixed) -20 to 50 °C (-4 to 122 °F) 25 or 35 ppm (switch selectable) 180 ppm (fixed) -20 to 50 °C (-4 to 122 °F) 1 ppm (fixed) 3 ppm (fixed) -20 to 50 °C (-4 to 122 °F) CO: 25 ppm (default)** 100 ppm (fixed)** NO2: 1 ppm (default)** CO: 180 ppm (default)** 500 ppm (fixed)** NO2: 3 ppm (default)** -20 to 40 °C (-4 to 104 °F) -20 to 50 °C (-4 to 122 °F) 100 ppm (fixed)** 500 ppm (fixed)** -20 to 50 °C (-4 to 122 °F) OPERATING 0 to 90% RH HUMIDITY RANGE non-condensing 0 to 90% RH non-condensing 0 to 90% RH non-condensing 0 to 90% RH non-condensing 0 to 90% RH non-condensing 0 to 90% RH non-condensing *The AG04 sensor works only with GWNP (protocol output) Series gas platform devices. The AG04 will not work with GWNM, GWNV or GWN1 versions of the GWN Series. **Low and high level setpoint can be adjusted between 0 and top of range if used with a GWNP (protocol) gas platform. DIMENSIONAL DRAWING 0.6" (15 mm) ORDERING INFORMATION - PLATFORM Output GWN* X P = Protocol (BACnet/Modbus) Housing Color X Blank = Black W = White Example: GWN P X X W 4.5" (113 mm) 3.25" (83 mm) *The GWNP will not operate without an AG Series sensor installed. Sensors are sold separately. 2.75" (70 mm) WIRING DIAGRAM 1.2" 1.1" (30 mm) (27 mm) Relay High Threshold (HT) + Low Threshold (LT) Common Power Supply Modbus RS485(-) BACnet RS485(+) GND Power 1.7" (42 mm) ORDERING INFORMATION REQUIRED SENSORS MODEL DESCRIPTION AG01 CO sensor, 3% accuracy. CO sources include exhaust from gasoline powered engines, furnaces, water heaters and generators. AG01E CO sensor, 5% accuracy. CO sources include exhaust from gasoline engines, furnaces, water heaters and generators AG02 NO2 sensor. NO2 sources include exhaust from diesel powered engines and generators. AG04 CO & NO2 combination sensor. CO sources include exhaust from gasoline powered engines, furnaces, water heaters and generators. NO2 sources include exhaust from diesel engines and generators AG05 R134a sensor. R134a is a refrigerant used in HVAC applications. AG06 R410a sensor. R410a is a refrigerant used in HVAC applications. Note: See Specifications section for AG sensor warranty details. ORDERING INFORMATION ACCESSORY ENCLOSURE MODEL AGPE DESCRIPTION Metal wall mount enclosure for the GWNP gas platform with audible horn and 10 A relay ACCESSORIES P. 93 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 88 Smoke Detection | Duct Mount Smoke Detector UG-7-A6O UNIGUARD® Optical Smoke Detector with Single High-Efficiency Sampling Tube Efficient Sampling Adjustable Highly efficient single sampling tube Automatic sensitivity adjustment. Multiple pickup tube lengths available. Easy to Install Single sampling tube allows quick installation. Device can be installed on any side of the duct. UG-7-A6O Series with pickup tube installed APPLICATIONS · Duct smoke detection in HVAC systems Smoke entering a duct system will be dispersed throughout the entire building. Uniguard duct detectors utilize the photoelectric sensing method and are designed to sense the existence of smoke in the duct. This housing design, along with the detector technology, is capable of detecting unsafe conditions by sampling the air in the duct. When smoke is detected, the Uniguard's relays provide a signal which may be used to turn off circulating fans, blowers and any other auxiliary devices that are connected to the system. This enables the management of hazardous smoke through the space being monitored by the duct detection arrangement. This Uniguard comes in two models: UG-7-A6O-24V operates with 24 Vdc/ac and UG-7-A6O-120V with 120 Vac. Alarm and supervisory relay contacts are accessible to interface with a control panel, HVAC control, and multiple auxiliary functions including turning off the fan. The Uniguard can be installed on any side of the duct. The UG-7-A6O detector contains an intelligent controlling circuit. This circuit is adjusting the sensitivity to give an optimal function during the entire lifetime of the detector. When the controlling circuit can no longer compensate for contamination, a service alarm is indicated. UG-7-A6O has a linking function that allows interconnection between a maximum of 100 units. The linking function can close dampers or stop fans further away in the ventilation system, before the smoke has reached the places were the linked detectors are installed. When one of the linked UG-7-A6O goes into smoke alarm, all other detectors' AUX relays are activated. SPECIFICATIONS Power Supply Voltage Reset Time (by power down) Power Up Time UG-7-A6O-24V: 24 Vdc (-5/+20%) 24 Vac (±10%), 50-60 Hz UG-7-A6O-120V: 110-120 Vac, 50-60 Hz 1 sec. max. 1 min. Sensitivity Test Nominal sensitivity 0.96 to 1.20%/ft. Max. Standby Current UG-7-A6O-24V: 42 mA (DC mode), 82 mA (AC mode) UG-7-A6O-120V: 31 mA at 120 Vac Max. Alarm Current UG-7-A6O-24V: 83 mA (DC mode), 145 mA (AC mode) UG-7-A6O-120V: 42 mA at 120 Vac Link Current 5 mA Total Max. Auxiliary Current Output, Terminals 2 & 5 Without linked detectors: 30 mA With linked detectors: 25 mA Operating Temperature 32 to 100 °F (0 to 38 °C) Storage Temperature -22 to 158 °F (-30 to 70 °C) Humidity 0 to 95% RH Duct Air Velocity Range 100 to 4000 ft/min (0.5 to 20.32 m/s) Dimensions (L x W x D) 11 x 6.5 x 3.27" (279 x 165 x 83 mm) Weight 1.04 kg Air Sampling Tube Aluminium, hole diameter 1.5" (38 mm) RELAY CONTACT RATINGS Alarm Initiation Contacts (SPST) 1.0 A @ 24 Vdc (resistive) 1.0 A @ 120 Vac (resistive) Supervisory Contacts (SPST) 1.0 A @ 24 Vdc (resistive) 1.0 A @ 120 Vac (resistive) Alarm Auxiliary Contacts (DPDT) 10 A @ 30 Vdc (resistive) 10 A @ 250 Vac (resistive) ½ HP @ 240 Vac ¼ HP @ 120 Vac WARRANTY Limited Warranty 2 years AGENCY APPROVALS Agency Approvals UL Signaling Listed: S24724 Fire Alarm Equipment Listed: California State Fire Marshall 89 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Smoke Detection | UG-7-A6O WIRING DIAGRAM First UG-7 detector in loop Power input UG-7-A6O-24V: 24V AC/DC UG-7-A6O-120V: 120V AC 17 18 1 GND/Detector Link out 2 Link out + 3 Link in 4 Link out + Auxiliary contact (fan shutdown, closing of damper etc. 11 N.O. 12 C. 13 N.C. 14 N.O. 15 C. 16 N.C. Supervisory and service alarm contact (faulty or removed smoke detector and power failure). C. N.C. 7 8 9 N.O. 10 C. Alarm initiation contact in standby position. Last UG-7 detector in loop Power input UG-7-A6O-24V: 24V AC/DC UG-7-A6O-120V: 120V AC 17 18 1 GND/Detector Link out 2 Link out + 3 Link in 4 Link out + Auxiliary contact (fan shutdown, closing of damper etc. 11 N.O. 12 C. 13 N.C. 14 N.O. 15 C. 16 N.C. Supervisory and service alarm contact (faulty or removed smoke detector and power failure). C. N.C. 7 8 9 N.O. 10 C. Alarm initiation contact in standby position. Alarm initation loop + Fire control panel Terminating resistor specified by the control panel manufacturer ORDERING INFORMATION MODEL DESCRIPTION CAL-UG-7-A6O-24V* SMOKE,DUCT,24V,UL CAL-UG-7-A6O-120V* SMOKE,DUCT,120V,UL CAL-ST1 SMOKE,ACCY,PICKUP TUBE,1FT CAL-ST2 SMOKE,ACCY,PICKUP TUBE,2FT CAL-ST5 SMOKE,ACCY,PICKUP TUBE,5FT CAL-ST9 SMOKE,ACCY,PICKUP TUBE,9FT CAL-UG-MB-75 SMOKE,ACCY,MOUNTING BRACKET CAL-UG-COVER-75 SMOKE,ACCY,CONDENSATION COVER *Pickup tube not included. Pickup tube ordered separately. DIMENSIONAL DRAWING Inches (mm) 11" (279 mm) 6.5" (165 mm) 3.27" (83 mm) 0.79" (20 mm) 1.17" (29.7 mm) 0.89" (22.6 mm) AIR PICKUP TUBE The air pickup tube has a continuous pickup along its entire length. The length of the pickup tube is chosen based on the width of the ventilation duct. Pickup tubes are available in four lengths: 1, 2, 5 and 9 ft (0.3, 0.6, 1.5 and 2.8 m). When the ventilation duct is wider than Ø 2 ft (0.6 m), the pickup tube should penetrate the whole duct. See diagram below. Hole diameter 1.5" (38 mm). Drill a hole Ø 1.5" (38 mm). Drill a hole Ø 1.5" (38 mm). Max diameter of the duct 2 ft (0.6 m). Use the pickup tube 1 or 2 ft (0.3 or 0.6 m). Shorten the tube if necessary. CAL-UG-COVER-75 For ducts with a ø of less than 0,6 m use the 0,6 m pipe. For ducts with a ø of between 0,6 m and 1,4 m use the 1,5 m pipe. For ducts which are larger than 1,4 m use the 2,8 m pipe. NOTE! Drill a hole Ø 2" (51 mm). Diameter of the duct bigger than 2 ft (0.6 m). The pickup tube should penetrate the entire duct. Shorten the tube to correct length. Insert the end plug. Put on the end plastic gasket. Put on the rubber gasket, HFU204. The pickup tube must not protrude more than 1" (30 mm) through the duct wall. CAL-UG-MB-75 Mounting Bracket CAL-STx Pickup Tube CAL-UG-COVER-75 Condensation Cover 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 93 90 Air Quality / Gas Detection | Ionization Systems and Sensors GPS SERIES Needlepoint Bipolar Ionization Systems GPS-FC48-AC GPS-DM48-AC Reduces particles Neutralizes odors Particle reduction and smoke control Odors neutralized by destroying VOCs Reduces pathogens Kills pathogens (bacteria, viruses, mold), helps to control allergens/asthma, prevents Dirty Sock Syndrome Saves energy Energy savings of up to 30% by reducing outdoor air intake, reducing pressure loss by keeping coils clean without an expensive UV system, and requires no maintenance GPS-FC24-AC GPS-iRIB-18 and GPS-iRIB-36 iMEASURE-D An ion is a molecule or atom that is positively or negatively charged, meaning it must either gain or relinquish electrons in order to become neutral. Naturally occurring ions are everywhere in the outdoors, and they are constantly working to clean the air. Ions are created with energy from rushing water, crashing waves and even sunlight. Needlepoint Bipolar Ionization (NPBI) technology cleans indoor air by generating ions without producing ozone or other harmful by-products, so you can bring outdoor freshness to the indoors. This patented technology produces a high concentration of positive and negative ions, delivering them to the space via the ventilation system. Within the air stream, ions attach to particles, where they combine, become larger and are more easily filtered from the air. When ions come in contact with pathogens, they disrupt the pathogens' surface proteins, rendering them inactive. Five separate in duct ionization systems to fit your application are offered. The iMEASURE-D Duct Ionization sensor allows for monitoring of levels of ionization in the air. Higher ionization levels means fewer active pathogens and larger particles more easily filtered out of the air. SPECIFICATIONS IONIZATION SYSTEMS Input Voltage GPS-FC and GPS-DM models: 24 to 240 Vac; GPS-iRIB models: 110 to 240 Vac Power GPS-FC24-AC: 8 Watts; GPS-FC48-AC: 10 Watts; GPS-DM48-AC: 12 Watts; GPS-iRIB: 5 Watts Frequency 50/60 Hz Ion Output GPS-FC48-AC/GPS-DM48-AC: >400 million ions/sec; GPS-FC24-AC: >300 million ions/sec; GPS-iRIB: >35 million ions/sec per foot GPS-FC48-AC/GPS-DM48-AC: 4800 CFM / 12 Tons; Airflow Capacity GPS-FC24-AC: 2400 CFM / 6 Tons; GPS-iRIB: 3200 CFM / 8 Tons APPLICATIONS · Healthcare · Schools and universities · Manufacturing · Office buildings · Airports · Food service · Fitness · Arenas and stadiums · Hospitality · Worship Status Display GPS-DM48-AC: LCD display indicates relay status and is used for adjustment of auto-cleaning frequency; GPS-FC models: Single LED indicates relay status and is used for adjustment of auto-cleaning frequency; GPS-iRIB models: Single LED indicates relay status Alarm Relay Rating 250 Vac / 1A, N.O. (close when powered with no faults) Operating Tem- GPS-FC and GPS-DM models: -20 to 200 °F (-29 to 93 °C); perature Range GPS-iRIB Models: -40 to 140 °F (-40 to 60 °C) Auto-Cleaning GPS-FC and GPS-DM models only: Mechanical wiper, default setting brushes every three days IONIZATION SENSOR Mounting Location Duct Input Voltage 12 to 24 Vac / Vdc Current draw 100 mA max. Sensor Range 0 to 20K, 0 to 200K, 0 to 2M Ions/cc (jumper selectable) Sensor Output 0 to 10 Vdc Power <2 Watts Operating Temperature Range -20 to 140 °F (-4 to 60 °C) Humidity Range 0 to 99% RH, non-condensing WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals UL867, OSHPD Seismic (OSP), IAQP, CE 91 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Air Quality / Gas Detection | GPS Series APPLICATION DIAGRAM 1 3 2 In-room ion density is dependent on a variety of factors, including proximity of the ionizing equipment to the occupied space, air flow rates and path of the ductwork within the building. Step 1: Conditioned air flows into the distribution duct system. Step 2: Air is ionized by the GPS device. Step 3: Positive and negative ions are delivered into the environment. INSTALLATION EXAMPLES From Air Handling Units to fan-powered boxes, Veris has the solution. E B E A A B D C A: DM48 B B: FC24 C: FC48 D: iRIB 18/36 E: iMEASURE-D DIMENSIONS MODEL GPS-DM48-AC GPS-FC48-AC GPS-FC24-AC INSERTION INSERTION L W H DEPTH DIAMETER 9.0" 7.75" 7.75" 7.0" 3.75" 11.1" 1.84" 3.52" 7.9" 1.1" 5" GPS-iRIB Power Unit 3.75" 1.75" 1.0" GPS-iRIB-18 Ionizer Strip 18.0" 1.5" 0.05" GPS-iRIB-36 Ionizer Strip 36.0" 1.5" 0.05" GPS-iMEASURE-D 12.1" 6.2" 3.25" 10.5" 2" AUTO-CLEANING TECHNOLOGY Auto-cleaning technology ensures sustained ion output over time. Ion output can decrease without this feature, in addition to accumulation of humidity and other material build-up. Competitive products and brushes must be manually cleaned, and while, a simple process, this rarely occurs. The auto-cleaning feature performs regular wipes of emitter brushes, which prevents build-up. The resulting benefit is optimal lifetime performance. ORDERING INFORMATION MODEL DESCRIPTION MOUNTING LOCATION GPS-DM48-AC Duct ionization system Through duct wall GPS-FC48-AC Duct ionization system Duct wall, duct floor, fan inlet GPS-FC24-AC Duct ionization system GPS-iRIB-18 GPS-iRIB-36 Flexible ionization strip Traditional split systems, PTACs, fan coils, air handlers, Flexible ionization strip ductless mini splits, ducted modules, ceiling cassettes * Multiple units can be combined to meet system air capacity requirements. DISPLAY LCD SELF-CLEANING X X X AIRFLOW CAPACITY 4800 CFM / 12 tons* 4800 CFM / 12 tons* 2400 CFM / 6 tons* 3200 CFM / 8 tons* 3200 CFM / 8 tons* MODEL GPS-iMEASURE-D DESCRIPTION Duct ionization sensor MOUNTING LOCATION OUTPUT RANGE SENSOR RANGE Duct wall, duct floor, fan inlet, AHUs 0 to 10 V 0 to 20K, 0 to 200K, 0 to 2M ions/cc (selectable) AIRFLOW CAPACITY 1,000 to 100,000 CFM 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 92 CD CDE CRLSXX GWN GWNP Air Quality / Gas Detection | Accessories ACCESSORIES SELECTION GUIDE: AIR QUALITY/ GAS DETECTION Product Description CO2 MONITORING AA01 CO2 Calibration Kit, Includes 16-Liter "Zero" Gas, Regulator Valve, Carrying Case & Tubing Kit AA26 17-Liter CO2 Span Calibration Gas (2000 ppm) -- Replacement Disposable Bottles AA27 103-Liter CO2 Span Calibration Gas (2000 ppm) -- Replacement Disposable Bottles AA28 17 liter CO2 Zero Calibration Gas -- Disposable Replacement Bottles AA29 103 liter CO2 Zero Calibration Gas -- Disposable Replacement Bottles AA35 Duct Aspiration Box (Allows Wall Mount CO2 Sensors to be Mounted into the Duct) AA36 CO2 Outdoor Aspirator Box (Allows Wall Mount CO2 Sensors to Sense Outdoor Air) AA50 Remote Sample Pick-up Kit CO Monitoring AA32 CO Test Verification Kit, 17 Liter AA37 CO Gas 100 PPM 17-Liter Disposable Replacement Gas (Requires Regulator Valve AA40) AA38 CO Gas 100 PPM 103-Liter Disposable Replacement Gas (Requires Regulator Valve AA41) AA39 CO Test Verification Kit, 103 Liter ··· ··· ··· ··· ··· · · ·· ·· ·· ·· 93 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Air Quality / Gas Detection | Accessories AA01 CO2 Calibration Kit, Includes 16-Liter "Zero" Gas, Regulator Valve, Carrying Case & Tubing Kit AA26 17-Liter CO2 Span Calibration Gas (2000 ppm) - Disposable Replacement Bottles AA27 103-Liter CO2 Span Calibration Gas (2000 ppm) - Disposable Replacement Bottles AA38 CO Gas 100 PPM 103 Liter Replacement Disposable Gas (Requires Regulator Valve AA41) AA39 Carbon Monoxide Test Verification Kit 103 Liter AA40 Regulator Valve for 17-Liter Bottle AA41 Regulator Valve for 103-Liter Bottle AA50 Remote Sample Pickup Kit 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 94 FLOW MONITORING Veris Industries offers an extensive range of devices for monitoring flow and the transfer of thermal energy in liquids. Our impeller models are available in insertion and tee styles for installation flexibility, including hot tap models for your convenience. Several non-impeller designs are also available, including an ultrasonic meter for sensing without cutting into a pipe, an electromagnetic meter for slurries, a nutating disc meter for industrial applications, and a turbine meter for long term service. We also carry a selection of transmitters and monitors, making us a "one-stop shop" for all your flow monitoring needs. MODEL SDI 220x, 228x 250x 380 310, 320, 340 Magnetoflow TFX5000 170, RCDL 450, 1000 B142/B3000 VN2000 FC-5000 O2 QSE DESCRIPTION Insertion Meter, Small Diameter Impeller (SDI) Insertion Meter, Standard Impeller/Hot Tap Tee Meter, Brass Tee Meter, BTU System Transmitter: Analog, BTU, Pulse, and Protocol Output Electromagnetic (Mag) Meter Ultrasonic Flow and Energy BTU Meter Nutating Disc Meter Turbine Meter Gas Turbine Flow Meter and Monitor Vortex Shedding Steam Meter Monitor: Local Display, Output and BTU Electronic Flow Meter with Scaled Pulse Output Electromagnetic Flow Meter PAGE 97 99 100 101 103 105 107 109 111 113 115 117 120 121 FLOW SENSOR SELECTION GUIDE FLOW SENSORS FEATURES INSERT PLASTIC TEE Basic Model 220x/ 228x page 99 228PV/735/ 4000 page 101 Hot Tap Capability SDI, 225x/ 226x pages 97, 98 BTU Measurement Small Diameter Impeller SDI page 97 Built-in Transmitter SDI page 97 METAL TEE 228x, 250x pages 99, 100 380 page 101 CLAMPON TRANSMITTERS AND MONITORS FEATURES ANALOG OUTPUT SCALED PULSE OUTPUT Transmitter 310 page 103 320 page 103 Transmitter with BTU Calculation 340 page 103 Flow Monitor with LCD Display 3000 page 117 3000 page 117 Ultrasonic Flow Monitor with LCD Display and BTU Calculation 3050 page 117 3050 page 117 PROTOCOL OUTPUT 340 page 103 3000 page 117 3050 page 117 SPECIALITY METERS FEATURES Non-Impeller Styles Electromagnetic page 105 Nutating Disc page 109 Turbine page 111 Ultrasonic page 107 Vortex Shedding page 115 95 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com MAXIMIZE EFFICIENCY WITH ECONOMY SOLUTIONS QSE and 02 Economy Flow and Energy BTU Meters Conserve resources by measuring your present consumption with Veris liquid flow and energy meters! FEATURES WIDE ARRAY OF FLUID MONITORING Including water, brine and raw sewage COMPLETE SYSTEM VIEW Net total measurement Energy Consumption (BTU) Chiller efficiency Waste water EASY SYSTEM INTEGRATION Many analog and protocol communications including Modbus and BACnet 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 96 Flow Monitoring | Insertion Meter, Small Diameter Impeller (SDI) SDI SERIES For Pipe Sizes 1-½" to Over 36" BGR-8SDI1D1N20-0200 NEMA 4 housing Rugged and weather-proof Highly durable Stainless steel impeller, tungsten carbide shaft and Torion® bearing Multiple outputs Scaled pulse and 4 to 20 mA output available Material options Other materials available. See chart on facing page. Fewer leaks Viton® O-ring seal standard BGR-8SDI0H1N20-0200 The direct insert style liquid flow sensor with stainless steel/PPS plastic or PEEK plastic tip combines flow sensing with a built-in transmitter for an all-in-one flow measuring system. This device fits all 1-1/2" to over 36" (38 to 915 mm) pipes, and it is intended for direct installation into the pipe through a 1" NPT hole. This sensor is available with or without hot tap capability. In the hot tap installation, the sensor is mounted in the pipe under pressure by attaching a service saddle or weld-on fitting to the pipe. Then the sensor assembly is attached to an isolation valve and extended into the pipeline to measure flow. Hot tap installations are often required in retrofit projects, but even in new construction, a hot tap sensor can be desirable for service considerations. Software and programming cable are required to operate these meters. If the meter will be used for hot tap installation, the BGR-8A1027 tool is also needed (see Ordering Information). APPLICATIONS · Flow measuring projects · True hot tap installations SPECIFICATIONS Recommended Design Flow 0.3 to 20 ft./sec Range Pressure Rating 1000 psi @ 21 °C (70 °F) Maximum Temp Rating 135 °C (300 °F) Operating Temperature Electronics: 20 to 65 °C (14 to 150 °F) Pressure Drop 0.5 psi or less @ 10 ft/sec for all pipe sizes 1.5" diameter and up Accuracy ±1% of rate over optimum flow range* Repeatability ±0.5% WARRANTY Limited Warranty 1 year * 10 upstream and 5 downstream straight pipe diameters, uninterrupted flow. · BTU applications (requires temperature sensors and transmitter/monitor) 97 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWINGS 4.375" (111 mm) Flow Monitoring | SDI Series D1 = 15.75" (400 mm) D2 = 19.25" (489 mm) D3 = 25.5" (648 mm) 4.25" (108 mm) 0.7" (18 mm) Handtight Engagement + Wrench Makeup Per ANSI/ASME B1.20.1-1993, R1992 1" NPT 7.75" (197 mm) isolation valve, top view 1" NPT 4.4" (112 mm) H1 = 19.0" (483 mm) H2 = 21.5" (546 mm) H3 = 27.5" (699 mm) 2.9" (74 mm) 7.9" (201 mm) isolation valve, side view ORDERING INFORMATION - COMMON CONFIGURATIONS VERIS PART # BGR-8A301-20* MANUFACTURER PART # DESCRIPTION 8A301-20* Flow, Programming Cable with CD for Badger/DI Prod, Serial PC Connector BGR-840134-0002* 840134-0002* Flow, Programming Data Converter with Cable and CD, USB PC Connector BGR-8SDI0D1N10-0200 8SDI0D1N10-0200 Flow, SDI, SS, 1.5 to 10, 4 to 20 mA, No Display BGR-8SDI0H1N10-0200 8SDI0H1N10-0200 Flow, SDI, Hot Tap, SS, 1.5 to 10, 4 to 20 mA, No Display BGR-8A1027** 8A1027** Flow, Tool, Hot Tap Adapter, 1" Machine to 1" NPT BGR-8SDI0D1N00-0200 8SDI0D1N00-0200 Flow, SDI, SS, 1.5 to 10, Frequency, No Display BGR-8SDI0H1N00-0200 8SDI0H1N00-0200 Flow, SDI, SS, 1.5 to 10, Hot Tap, Frequency, No Display * Software and programming cable are required for analog, Modbus, LonWorks, BACnet transmitter and meter products. ** A1027 required to adapt SDI hot tap sensor 1" machine thread to 1" NPT for hot tap drilling tools. ORDERING INFORMATION - SPECIAL ORDER MODELS*** Material 8SDI Type Electronic Housing N Output Display O-Ring Shaft Impeller 0 Bearing 0 0 = Stainless Steel/ PPS plastic Tip 1 = Brass/PPS plastic Tip (no Hot Tap) 2 = Stainless Steel/ PEEK plastic Tip D1 = Direct Insert for Pipe 1½ - 10" D2 = Direct Insert for Pipe 12 - 36" D3 = Direct Insert 36" and up H1 = Hot Tap for Pipe 1½ - 10" H2 = Hot Tap for Pipe 12 - 36" H3 = Hot Tap 36" and up = NEMA 4X 0 = Frequency (standard) 0 = No Display 1 = Analog 4 to 20 mA 1 = LCD Option 2 = Scaled Pulse (requires output 5 = Bidirectional, analog, option 1 or 2) 4 to 20 mA (hot tap SS only) 6 = Bidirectional, scaled pulse (hot tap SS only) 0 = Viton® (standard) 1 = EDPM 2 = AFLAS® Example: 0 = Zirconia Ceramic = Stainless Steel (optional) 1 = Hastelloy® C-276 (optional) 2 = Tungsten Carbide (standard) 8SDI 1 D3 N 6 0 0 2 0 0 *** Consult Veris sales to order these models. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 98 Flow Monitoring | Insertion Meter, Standard Impeller / Hot Tap 220X & 228X SERIES For Pipe Sizes 3" to Over 40" BGR-8220SS0005-1211 2000 ft signal travel Signal can travel up to 2000 ft (609 m) between the sensor and the display unit without the need for amplification Cable options Supplied with 20 ft (6 m) of 2-conductor AWG 20 UL type PTLC cable (105 °C rated) Non-magnetic sensing Six-bladed impeller design with a proprietary, non-magnetic BGR-8220BR0005-1211 sensing mechanism for high accuracy and repeatability. Forward-swept impeller is less BGR-8228CB2005-1211 prone to fouling by water-borne debris...reliable performance Insert-style liquid flow sensors with brass or stainless steel sleeves with minimal downtime. fit pipe sizes from 3" to 40" (77 to 1016 mm). These sensors can be DIMENSIONAL DRAWINGS purchased with a bronze or iron tee. Sensor output is a frequency that indicates flow rate. Used in conjunction with a compatible flow monitor 3" or transmitter, these non-magnetic flow sensors provide an accurate (76 mm) 2" NPT reading of the rate of liquid flow, as well as total accumulated flow. 1.5" (38 mm) (insertion depth) 1.75" (45 mm) SPECIFICATIONS Temperature Rating 105 °C (221 °F) continuous Pressure Rating At 38 °C (100 °F) Insert: 400 psi; brass tee: 200 psi; iron tee: 175 psi Recommended Design Flow Range 0.5 to 30 ft/sec (0.15 to 9 m/sec); initial detection below 0.3 ft/sec Wetted Materials UHMW-PE bearing, polyamide impeller, tungsten carbide shaft, EPDM O-rings Accuracy 1% F.S. over recommended design flow range; ±4% of reading within calibration range* Repeatability ±0.3% of full scale over recommended design flow range* Linearity ±0.2% of full scale over recommended design flow range* Output Frequency 3.2 Hz to 200 Hz Output Pulse Width 5 ms ±25% WARRANTY Limited Warranty 1 year * 10 upstream and 5 downstream straight pipe diameters, uninterrupted flow. 1/2 - 14 NPT 5.25" (133 mm) 7.2" (183 mm) Pipe I.D. 9" (229 mm) 4.5" (114 mm) ORDERING INFORMATION VERIS PART # MANUF. PART # BGR-8220BR0005-1211 8220BR0005-1211 BGR-8220SS0005-1211 8220SS0005-1211 BGR-8228BR2005-1211 8228BR2005-1211 BGR-8228CB2005-1211 8228CB2005-1211 BGR-8228BR2505-1211 8228BR2505-1211 DESCRIPTION Flow, Sensor, Insert, Brass Sleeve, 3" to 40" (77 to 1016 mm) pipe Flow, Sensor, Insert, SS Sleeve, 3" to 40" (77 to 1016 mm) pipe Flow, Sensor, Insert, Brass, 2" Brass Tee Flow, Sensor, Insert, Brass, 2" Iron Tee Flow, Sensor, Insert, Brass, 2.5" Brass Tee 99 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | 250x Series 250X SERIES For Pipe Sizes ½" to 1½" NPT 2000 ft signal travel Signal can travel up to 2000 ft (609 m) between the sensor and the display unit without the need for amplification No amplification Signal can travel up to 2000 ft (609 m) between the sensor and the display unit without the need for amplification BGR-8250BR0505-1211 Metal tee-style liquid flow sensor with cast brass housing fits ½" to 1½" NPT. These sensors are accurate, even at low flow rates. Use in conjunction with a flow monitor or transmitter for a complete flow monitoring system. SPECIFICATIONS Maximum Pressure Wetted Materials Recommended Flow Accuracy Repeatability Linearity Rangeability Output Frequency WARRANTY Limited Warranty At 38 °C (100 °F) 400 psi; at 105 °C (221 °F) 325 psi UHMW-PE bearing, polyamide impeller, tungstencarbide shaft, EPDM O-rings 0.3 to 15 ft/sec (0.09 to 4.5 m/sec) ±1.0% of rate ±0.7% over recommended design flow range* ±0.7% over recommended design flow range* 60:1 0.8 to 80 Hz 1 year * 10 upstream and 5 downstream straight pipe diameters, uninterrupted flow. APPLICATION EXAMPLE 4 to 20 mA output Frequency Signal Data ® Industrial 4-20mA Loop(-) 4-20mA Loop(+) Shield Ground Signal (-) Signal (+) Power (4000 only) Fluid Monitoring System Sensor Inputs D.I.C. Comm Port 310 Flow Transmitter 250BR Sensor, in line with fluid pipe Ideal for low flow rates Operation and repeatability even at low flow rates Cable options Supplied with 20 ft (6 m) of 2-conductor AWG 20 UL type PTLC cable (105 °C rated) Non-magnetic sensing Highly durable PPS electronics housing Six-bladed impeller design with a proprietary, non-magnetic sensing mechanism for high accuracy and repeatability. Forward-swept impeller is less prone to fouling by water-borne debris...reliable performance with minimal downtime. APPLICATIONS · Measuring liquid flow rates DIMENSIONAL DRAWING Model A B C BGR-8250BR0505-1211 4.0" 4.7" 1.7" (102 mm) (120 mm) (44 mm) B BGR-8250BR0705-1211 4.0" 4.7" 1.7" (102 mm) (120 mm) (44 mm) BGR-8250BR1005-1211 5.5" 4.8" 2.2" C (140 mm) (121 mm) (56 mm) BGR-8250BR1205-1211 6.1" 5.0" 2.4" (155 mm) (127 mm) (61 mm) A BGR-8250BR1505-1211 6.5" 5.2" 2.7" (165 mm) (132 mm) (69 mm) ORDERING INFORMATION VERIS PART # BGR-8250BR0505-1211 BGR-8250BR0705-1211 BGR-8250BR1005-1211 BGR-8250BR1205-1211 BGR-8250BR1505-1211 MANUF. PART # 8250BR0505-1211 8250BR0705-1211 8250BR1005-1211 8250BR1205-1211 250BR1505-1211 DESCRIPTION Flow, Sensor, 1/2" Cast Brass Tee Flow, Sensor, 3/4" Cast Brass Tee Flow, Sensor, 1" Cast Brass Tee Flow, Sensor, 1-1/4" Cast Brass Tee Flow, Sensor, 1-1/2" Cast Brass Tee 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 100 Flow Monitoring | Tee Meter, BTU System 380 SERIES Measures Temperature and Flow Rate and Calculates Energy BACnet & Modbus BACnet and Modbus protocols are standard features...easy integration with existing control systems Integrated flow & temperature Integration of flow and temperature sensors with metering components...single solution for BTU metering Easy installation Minimal connections...simplify installation, saving time and cost Two temperature probes Rugged, compact design with two temperature probes Series 380 BTU system provides a low-cost system for metering hot and cold systems. The 380 measures flow and temperature differential to accurately calculate energy. With BACnet, Modbus RS-485, or scaled pulse output, it can interface with many existing control systems. The rugged design incorporates an impeller flow sensor and two temperature probes, one mounted in the flow sensor tee and the other on either the supply or return line, depending on the application. Commissioning can be done in the field via a computer connection or set up at the factory. Setup includes energy measurement units, measurement method, communication protocol, pulse output control, fluid density, and specific heat parameters (requires re-usable programming cable and software, see Ordering Information). Stainless steel impeller 316 stainless steel impeller with tungsten carbide shaft APPLICATIONS · Energy management · Data systems SPECIFICATIONS Input Power Communication Output Flow Calculation Accuracy Temperature Sensors Flow Range Pressure MATERIALS Housing Flow Sensor Potting Material Tee Material ENVIRONMENTAL Fluid Temperature Ambient Temperature WARRANTY Limited Warranty 12 to 35 Vdc/12 to 28 Vac, 200 mA Modbus RTU, BACnet MSTP Scaled pulse, open drain ±2% of flow rate within range; 0.5% repeatability Meets IEC751 Class B 1 to 15 FPS Up to 400 psi Polycarbonate PEEK Polyurethane Bronze -20 to 126 °C (-4 to 260 °F) -20 to 65 °C (-4 to 149 °F) 1 year Sensor PEEK sensor tip 101 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 250x Series DIMENSIONAL DRAWING Side View Flow Monitoring | 380 Series Top View B Overall Height T1 PG-7 PG-9 RTD Fitting 1/8" NPT D Hex C Tee Length A Overall Length T2 Length 6.6' (2m) Ø 0.2 " (6 mm) Ø 8" 360° pivot area case E from center of tee Width TEE/NPT SIZE 2" (51 mm) 1.5" (38 mm) 1.25" (32 mm) 1" (25.4 mm) 0.75" (19 mm) A 7.9" (201 mm) 7.3" (185 mm) 7.1" (180 mm) 6.7" (170 mm) 6.7" (170 mm) B 8.5" (216 mm) 8.3" (209 mm) 8.1" (204 mm) 7.9" (201 mm) 7.9" (201 mm) C 7.8" (197 mm) 6.7" (170 mm) 6.2" (158 mm) 5.4" (137 mm) 5.4" (137 mm) D 3.3" (84 mm) 2.75" (70 mm) 2.4" (60 mm) 2" (51 mm) 2" (51 mm) E 3.5" (89 mm) 3.5" (89 mm) 3.5" (89 mm) 3.5" (89 mm) 3.5" (89 mm) ORDERING INFORMATION VERIS PART # BGR-8380207000-1202* BGR-8380210000-1202* BGR-8380212000-1202* BGR-8380215000-1202* BGR-8380220000-1202* MANUF. PART # 8380207000-1202 8380210000-1202 8380212000-1202 8380215000-1202 8380220000-1202 DESCRIPTION BTU system, hot and cold service, ¾" tee NPT, with pulse, Modbus and BACNet outputs BTU system, hot and cold service, 1" tee NPT, with pulse, Modbus and BACNet outputs BTU system, hot and cold service, 1-¼" tee NPT, with pulse, Modbus and BACNet outputs BTU system, hot and cold service, 1-½" tee NPT, with pulse, Modbus and BACNet outputs BTU system, hot and cold service, 2" tee NPT, with pulse, Modbus and BACNet outputs MAX. GAL/MIN (GPM) 25 40 70 95 150 BGR-8A304-1M ** 8A304-1M Programming Cable with CD for 380 Series n/a * Requires programming accessory. ** Required to program 380 Series BTU meters (reusable). Standard USB type A to mini-B cable included. Software available from manufacturer's website, www.badgermeter.com 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 102 Flow Monitoring | Transmitter: Analog, BTU, Pulse and Protocol Output 3X0 SERIES Converts Flow Signal to a Linear 4 to 20 mA Analog or a Protocol Signal Compact Communicating Saves space in crowded enclosures Communication protocols available on the 340 models BGR-8340-00 BGR-8310-00 BGR-8320-00 3x0 programmable transmitters are capable of converting the frequency signal from any compatible flow sensors to a preferred output type (analog, scaled pulse, protocol). In addition to standard square wave signals, it can also accept a sine wave, making it a versatile transmitter for numerous applications. The 310 and 320 offer analog and scaled pulse output, respectively, while the 340 models offer communication protocols (N2, BACnet/Modbus, or LonWorks), with energy (BTU) measurement (appropriate software and programming cables are required for installation; see Ordering Information). SPECIFICATIONS 310-00 Power Requirements Input Frequency Load Resistance Operating Temp Range Storage Temp Range Accuracy Linearity WARRANTY Limited Warranty Loop input voltage 9 to 35 Vdc 0.4 Hz to 10 kHz Max 750 @ 24 Vdc -29 to 70 °C (-20 to 158 °F) -40 to 85 °C (-40 to 185 °F) ±0.04% of reading over entire span 0.1% of full scale 1 year Programmable Programmable (units of measure, calibration, etc.) using computer with Windows®based operating system...save installation time in the field by pre-programming the device Input options Accepts sine wave input from a variety of other sources for application flexibility APPLICATIONS · Converting sine/square wave signals to 4 to 20 mA or protocol · Increasing wire run length limit for flow sensors · Connecting flow sensors to BAS panels 320-00 Power Requirements Input Frequency Transient Suppression Pulse Output Maximum Sinking Current Operating Temp Range Storage Temperature Range WARRANTY Limited Warranty 12 to 24 Vac 85 mA max.; 12 to 35Vdc, 30 mA max.; reverse and over voltage protected to 40 Vdc 0.4 to 10 kHz Complies with IEC-801-4 electrical burst, fast transient specification Isolated solid state switch in any standard or custom flow total units; adjustable 50 ms to 1.0 sec pulse output width in 50 ms increments 100 mA @ 35 Vdc -29 to 70 °C (-20 to 158 °F) -40 to 85 °C (-40 to 185 °F) 1 year 340-00 Power Requirements Flow Sensor Input Frequency Temp Sensor Input Operating Temp Range Storage Temp Range UNITS OF MEASURE Flow Rate Total Flow Energy Rate Total Energy WARRANTY Limited Warranty 12 to 24 Vdc or 12 to 24 Vac, 70 mA max. Excitation voltage 3-wire sensors: 9.1 Vdc 500 source impedance 4 to 10000 Hz 10k Dale Thermistor (requires two, sold separately) -29 to 70 °C (-20 to 158 °F) -40 to 85 °C (-40 to 185 °F) gpm, gph, l/sec, l/min, l/hr, ft3/sec, ft3/min, ft3/ hr, m3/sec, m3/min, m3/hr gallons, liters, cubic feet, cubic meters kBTU/min, kBTU/hr, kW, MW, hp, tons BTU, kBTU, MBTU, kWh, MWh, kJ, MJ 1 year 103 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com BGR-8310-00 Dimensional Drawing 1.5" (39 mm) 1.75" (45 mm) 0.9" (23 mm) BGR-8340-00 Dimensional Drawing 1.6" (40 mm) 3.0" (75 mm) 4-20mA Loop(-) 4-20mA Loop(+) Shield Ground Signal (-) Signal (+) Power (4000 only) Side 3.7" (94 mm) Data ® Industrial Mattapoisett, MA 02739 Model: 310 Programmable Analog Transmitter Sensor Inputs S/ N: 310-00000 D.I.C. Comm Port 2.75" (70 mm) 3.25" (83 mm) Side 3.7" (94 mm) 1.5" (39 mm) 0.9" (23 mm) 0.6" (15 mm) Flow Monitoring | 3x0 Series BGR-8320-00 Dimensional Drawing 1.5" (39 mm) Side 3.7" (94 mm) 1.75" (45 mm) 0.9" (23 mm) 2.75" (70 mm) 3.25" (83 mm) 1.5" (39 mm) ORDERING INFORMATION VERIS PART # MANUF. PART # DESCRIPTION BGR-8310-00 8310-001, 2 Flow Transmitter, Analog, Programmable, 4 to 20 mA Output BGR-8340BN/ MB-00 8340BN/MB-001, 2 Flow Transmitter, BTU, BN-MB, No Enclosure BGR-8340BN/ MB-03 8340BN/MB-031, 2 Flow Transmitter, BTU, BN-MB, Plastic Enclosure BGR-8320-00 8320-001, Flow Transmitter, Programmable, Scaled Pulse Output BGR-8340-00 8340-001, 2 Flow Transmitter, Programmable, Frequency Output BGR-8A301-20 8A301-20 Programming Cable with CD for Analog/ Modbus/BACnet/LonWorks Outputs, Serial PC Connector BGR-40134-0002 840134-0002 Programming Cable with CD for Analog/ Modbus/BACnet/LonWorks Outputs, USB PC Connector 1. Software and programming cable are required for analog, Modbus, BACnet transmitter and meter products. 2. 340 Series also requires two 10k T2 thermistors for energy (BTU) measurement. ACCESSORIES Veris TI Series immersion temperature sensors with 10K Type 2 thermistor work with the 340 Series transmitters with BTU. TIH TIG 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 104 Flow Monitoring | Electromagnetic (Mag) Meter ELECTROMAGNETIC SERIES Measure Fluid Flow in Wastewater and Slurries Reliable, durable design Open flow tube design...no head loss, no moving parts to fail Password security Protect against unwanted program changes 0.25% accuracy Wide flow range 0.25% accuracy independent of fluid Exceeds operating characteristics viscosity, density, and temperature of turbine and propeller meters Electromagnetic Series Electromagnetic (mag) flow meters are capable of measuring flow in almost any liquid, slurry, or paste with a minimum of electrical conductivity using Faraday's law of induction. These meters are highly accurate, at 0.25% or better, exceeding AWWA accuracy standards for mechanical meters. The smart, micro-processor based electronics are simple to operate, with AMR and SCADA ready standard outputs. The NEMA 4X enclosure provides durability. Bi-directional Bi-directional flow measurement capability...suitable for inter-city billing APPLICATIONS · Monitoring flow in systems likely to contain solids Well & reclaimed water Works with most solids common in liquid systems...great for well water and reclaimed water systems...not fouled by sand, gravel, or debris SPECIFICATIONS Flow Range Max. Operating Pressure Accuracy Repeatability Analog Outputs Digital Outputs Pulse Outputs Flow Direction Coil Power Minimum Conductivity Electrode Materials Liner Material 0.1 to 39.4 fps (0.03 to 12 m/s) 150 psi ±0.25% of rate for velocities greater than 1.64 fps (0.50 m/s); ±0.004 fps (±0.001 m/s) for velocities less than 1.64 fps (0.50 m/s) ±0.1% 4 to 20 mA, 0 to 20 mA, 0 to 10 mA, 2 to 10 mA (programmable and scalable) Voltage sourced 24 Vdc (isolated); max. loop resistance < 800 Four total, configurable 24 Vdc sourcing active output (up to two), 100 mA total, 50 mA each; sinking open collector output (up to four), 30 Vdc max., 100 mA each; AC solid-state relay (up to two), 48 Vac, 500 mA max. Scalable up to 10 kHz, passive open collector up to 10 kHz, active switched 24 Vdc. Up to two outputs (forward and reverse) Pulse width programmable from 1 to 1100 ms or 50% duty cycle Unidirectional or bidirectional, two separate totalizers (programmable) Pulsed DC 5.0 micromhos/cm Standard: alloy C; Optional: 316 stainless steel, gold/platinum plated, tantalum, platinum/rhodium PFA up to 3/8", PTFE 1/2" thru 24", soft or hard rubber from 1" thru 54" NSF Listed Fluid Temperature Pipe Spool Material Meter Housing Material Flanges Meter Enclosure Classification Junction Box Enclosure Protection Cable Entries Optional Stainless Steel Grounding Ring Thickness POWER SUPPLY AC DC (optional) WARRANTY Limited Warranty Models with hard rubber liner 4" size and up; Models with PTFE liner all sizes With remote amplifier: PFA, PTFE, 155 °C (311 °F) With Meter Mounted Amplifier: Rubber 80 °C (178 °F); PFA, PTFE 100 °C (212 °F) 316 stainless steel Carbon steel welded Standard (ANSI B16.5 Class 150 RF): carbon steel; Optional: 316 stainless steel NEMA 4X (IP66); Optional: Submersible NEMA 6P (remote amplifier required) For remote amplifier option: powder coated die-cast aluminum, NEMA 4 (IP65) ½" NPT cord grip For meter sizes up to 10": 0.135" thickness per ring; For meter sizes above 10": 0.187" thickness per ring 85 to 265 Vac; typical power: 20 VA or 15 W; max. power: 26 VA or 20 W 10 to 36 Vdc; Typical power: 10 W; max. power: 14 W 2 years 105 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | Electromagnetic Series ELECTROMAGNETIC SERIES Dimensional Drawings 7.1" (180 mm) 1.1" (27 mm) 3.3" (88 mm) 7.1" (180 mm) B Ø C 1.1" (27 mm) 4.8" (122 mm) 4.7" (120 mm) 3.2" (80 mm) D Ø Size A Meter with M2000 ampli er Size inch mm 2 50 3 80 4 100 6 150 8 200 10 250 A inch mm 8.9 225 11.0 280 11.0 280 15.8 400 15.8 400 19.7 500 B inch mm 15.9 403 17.3 440 18.4 466 20.6 524 22.5 572 26.8 681 C inch mm 6.0 152 7.5 191 9.0 229 11.0 279 13.5 343 16.0 406 Note: Other meter sizes and configurations are available. Consult Veris for availability. Meter with junction box for remote M2000 ampli er D Est. Weight with M-2000 inch mm lb kg 13.2 335 26 11.5 14.7 372 54 24.5 15.7 398 56 25.5 17.9 456 60 27.0 20.4 518 86 39.0 24.1 613 178 81.0 Flow Range LPM min max 4.70 1400 12 3600 19 5600 40 12700 75 22600 120 35300 GPM min max 1 373 3 956 5 1493 11 3361 20 5975 30 9336 ORDERING INFORMATION VERIS PART # MANUF. PART # BGR-M2-020-R1-A-MWWS-XXGF M2-020-R1-A-MWWS-XXGF BGR-M2-030-R1-A-MWWS-XXGF M2-030-R1-A-MWWS-XXGF BGR-M2-040-R1-A-MWWS-XXGF M2-040-R1-A-MWWS-XXGF BGR-M2-060-R1-A-MWWS-XXGF M2-060-R1-A-MWWS-XXGF BGR-M2-080-R1-A-MWWS-XXGF M2-080-R1-A-MWWS-XXGF BGR-M2-020-R1-A-RAFS-XXGF M2-020-R1-A-RAFS-XXGF BGR-M2-030-R1-A-RAFS-XXGF M2-030-R1-A-RAFS-XXGF BGR-M2-040-R1-A-RAFS-XXGF M2-040-R1-A-RAFS-XXGF BGR-M2-060-R1-A-RAFS-XXGF M2-060-R1-A-RAFS-XXGF BGR-M2-080-R1-A-RAFS-XXGF M2-080-R1-A-RAFS-XXGF BGR-M2-020-R1-A-MWWM-XXGF M2-020-R1-A-MWWM-XXGF BGR-M2-030-R1-A-MWWM-XXGF M2-030-R1-A-MWWM-XXGF BGR-M2-040-R1-A-MWWM-XXGF M2-040-R1-A-MWWM-XXGF BGR-M2-060-R1-A-MWWM-XXGF M2-060-R1-A-MWWM-XXGF BGR-M2-080-R1-A-MWWM-XXGF M2-080-R1-A-MWWM-XXGF BGR-M2-020-R1-A-RAFM-XXGF M2-020-R1-A-RAFM-XXGF BGR-M2-030-R1-A-RAFM-XXGF M2-030-R1-A-RAFM-XXGF BGR-M2-040-R1-A-RAFM-XXGF M2-040-R1-A-RAFM-XXGF BGR-M2-060-R1-A-RAFM-XXGF M2-060-R1-A-RAFM-XXGF BGR-M2-080-R1-A-RAFM-XXGF M2-080-R1-A-RAFM-XXGF Note: Other meter sizes and configurations are available. Consult Veris for availability. DESCRIPTION Flow, Mag, 2", Hard Rubber Liner, 4-20mA/Freq Flow, Mag, 3", Hard Rubber Liner, 4-20mA/Freq Flow, Mag, 4", Hard Rubber Liner, 4-20mA/Freq Flow, Mag, 6", Hard Rubber Liner, 4-20mA/Freq Flow, Mag, 8", Hard Rubber Liner, 4-20mA/Freq Flow, Mag, 2", Hard Rubber Liner, 30'Remote Amp, 4-20mA/Freq Flow, Mag, 3", Hard Rubber Liner, 30'Remote Amp, 4-20mA/Freq Flow, Mag, 4", Hard Rubber Liner, 30'Remote Amp, 4-20mA/Freq Flow, Mag, 6", Hard Rubber Liner, 30'Remote Amp, 4-20mA/Freq Flow, Mag, 8", Hard Rubber Liner, 30'Remote Amp, 4-20mA/Freq Flow, Mag, 2", Hard Rubber Liner, 4-20mA/Freq/Modbus Flow, Mag, 3", Hard Rubber Liner, 4-20mA/Freq/Modbus Flow, Mag, 4", Hard Rubber Liner, 4-20mA/Freq/Modbus Flow, Mag, 6", Hard Rubber Liner, 4-20mA/Freq/Modbus Flow, Mag, 8", Hard Rubber Liner, 4-20mA/Freq/Modbus Flow, Mag, 2", Hard Rubber Liner, 30'Remote Amp, mA/F/Modbus Flow, Mag, 3", Hard Rubber Liner, 30'Remote Amp, mA/F/Modbus Flow, Mag, 4", Hard Rubber Liner, 30'Remote Amp, mA/F/Modbus Flow, Mag, 6", Hard Rubber Liner, 30'Remote Amp, mA/F/Modbus Flow, Mag, 8", Hard Rubber Liner, 30'Remote Amp, mA/F/Modbus 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 106 Flow Monitoring | Ultrasonic Flow and Energy BTU Meter TFX5000 SERIES Accurate Readings from Outside the Pipe Wide range of measurable fluids Water, brine, sewage, ethylene glycol, glycerin, and more... flexibility in commercial and industrial applications Communicating Modbus RTU or BACnet MS/TP over EIA-485 and Modbus TCP/IP 2"+ Transducersr BGR-TFX5000 Meter Bi-directional Measure forward flow, reverse flow, and net total Rugged housing Compact, rugged aluminum housing...long service in harsh environments 3/4" & 1" Transducers Temperature Sensors for BTU Models Transit time flow meters measure the time difference between the travel time of an ultrasound wave going with the fluid flow and against the fluid flow. The time difference is used to calculate the velocity of the fluid traveling in a closed-pipe system. The transducers used in transit time measurements operate alternately as transmitters and receivers. Transit time measurements are bi-directional and are most effective for fluids that have low concentrations of suspended solids and are sonically conductive. An ultrasonic meter equipped with heat flow capabilities measures the rate and quantity of heat delivered or removed from devices such as heat exchangers. By measuring the volumetric flow rate of the heat exchanger liquid, the temperature at the inlet pipe and the temperature at the outlet pipe, the energy usage can be calculated. SPECIFICATIONS SYSTEM Flow Accuracy Velocity Repeatability Straight Run Requirements MONITOR Power Display Keypad Housing 3/4 in. (20 mm) ±1% of full scale 1 in. (25 mm) ±1% ± 0.03 ft/s (0.009 m/s) of reading 2+ in. (50mm+) ± 0.5% ± 0.025 ft/s (0.008 m/s) of reading 3/4 and 1 in. up to 20 ft/s, depending on pipe and fluid 2+ in. (50mm+) up to 40 ft/s, depending on pipe and fluid 0.2% above 1.5 ft/s 10 diameters upstream, 5 diameters downstream from single elbow 85 to 264V AC 47 to 63 Hz @ 24VA max. 1 Amp slow-blow fuse, manually field replaceable. Over-Voltage Rating Category II (CAT II) 128 × 64 pixel LED backlit graphical display; adjustable brightness and timeout; polycarbonate window Flow rate/total: 8-digit 4-button navigation, keypad with tactile feedback; polyester film Aluminum construction, EPDM Gasket, NEMA Type 4X, IP67 No fluid contact Safe from fouling and damage from system pressure LCD display Easy to read APPLICATIONS · Liquid flow meter for water delivery, sewage, cooling water, glycol, alcohol and chemicals · Heating/cooling energy flow meter ideal for hydronic process and HVAC Ambient Temperature Range Humidity Velocity Engineering Units (User Configured) Energy Version Outputs Communication Protocols TRANSDUCERS Construction WARRANTY Limited Warranty AGENCY APPROVALS -4 to 140 ° F (-20 to 60 °C) 0 to 85%, non-condensing feet/second, meters/second Gal, liters, million gal, ft3, m3, acre-ft, oil barrels (42 gal); liquor barrels (31.5 gal), ft, m, lb, kg* BTU, MBTU, MMBTU, Ton, Kwh, Kcal* 4 to 20mA: 1 for Flow Model, 2 for Energy Model; Frequency Output, Pulse (totalizer, programmable) EIA-485: Modbus RTU or BACnet MS/TP Ethernet: 10/100 Base T RJ45, communication via Modbus TCP/IP 3/4 in. (20 mm) and 1 in. (25 mm): CPVC, Ultem®, Nylon cord grip, PVC cable jacket; 40 to 194° F (-40 to 90°C) 2+ in. (50mm+): PBT glass filled, Ultem®, Nylon cord grip; PVC cable jacket; 40 to 250° F (40 to 121° C) 1 year ® MET C US Electrical and Hazardous Location Safety E112904 (FSR Only) * Additional non-HVAC units available in display menu. 107 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com BGR-TXF5000 METER Dimensional Drawing 6.50 in. (165.10 mm) 6.50 in. (165.10 mm) OPERATING EXAMPLE 3.63 in. (92.20) 0.50 in. (12.70 mm) Flow Monitoring | TFX5000 Series TRANSDUCERS FOR PIPES AND TUBING 3/4" AND 1" Dimensional Drawing B D A C TRANSDUCERS FOR PIPES LARGER THAN 2" Dimensional Drawing D TOP VIEW OF PIPE PIPE PIPE SIZE MATERIAL A B C ANSI 3/4" Copper 2.46" (63 mm) 2.46" (63 mm) 2.57" (66 mm) 2.50" (64 mm) 2.66" (68 mm) 3.56" (91 mm) ANSI 1" Copper 2.46" (63 mm) 2.46" (63 mm) 2.92" (75 mm) 2.87" (73 mm) 2.86" (73 mm) 3.80" (97 mm) 2"+ Multi 3.75" (95 mm) 3.35" (60 mm) Note: Other transducer sizes available. Consult Veris for availability. D 1.050" (27 mm) 0.875" (23 mm) 1.315" (34 mm) 1.125" (29 mm) 2.19" ( 56 mm) ORDERING INFORMATION VERIS PART # DESCRIPTION BGR-DQ-G-RZ-R-S-AK-WW-N-XX-TGF Flow Meter, 2+" Pipe, 110-220V, Keypad, 50' Cables, 4-20mA, Freq, Pulse, BACnet/Modbus BGR-DR-G-RZ-R-S-AKWWCAKNXXTGRF Flow Meter, BTU, 2+" Pipe, 110-220V, Keypad, 50' Cables, 4-20mA, Freq, Pulse, BACnet/Modbus BGR-DR-G-CB-R-S-AKWWCAKNXXTGRF Flow Meter, BTU, 3/4" Steel Pipe, 110-220V, Keypad, 50' Cables, 4-20mA, Freq, Pulse, BACnet/Modbus BGR-DR-G-CH-R-S-AKWWCAKNXXTGRF Flow Meter, BTU, 3/4" Copper Pipe, 110-220V, Keypad, 50' Cables, 4-20mA, Freq, Pulse, BACnet/Modbus BGR-DR-G-CC-R-S-AKWWCAKNXXTGRF Flow Meter, BTU, 1" Steel Pipe, 110-220V, Keypad, 50' Cables, 4-20mA, Freq, Pulse, BACnet/Modbus BGR-DR-G-CT-R-S-AKWWCAKNXXTGRF Flow Meter, BTU, 1" Copper Pipe, 110-220V, Keypad, 50' Cables, 4-20mA, Freq, Pulse, BACnet/Modbus Note: Other meter sizes and configurations are available. Consult Veris for availability. HQ0007944.A 0221 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | Nutating Disc Meter NUTATING DISC SERIES Cost-effective Metering for Industrial Applications Wide flow range Durable components Increased accuracy at high and low flow rates Minimal maintenance required Rugged construction Rugged bronze or plastic construction Increased versatility Optional pulse output transmitter Nutating Disc positive displacement meters are a cost-effective solution for industrial flow monitoring. These devices are available in sizes from 1/2" to 2" and are capable of handling flows up to 170 gallons per minute. Maintenance is fast, easy, and rarely required. The meter houses a measurement chamber that contains a disc. Liquid flowing through the chamber causes this disc to nutate, or wobble. This motion is sensed by a magnet, which transmits flow data. SPECIFICATIONS Max. Flow Rate Max. Operating Pressure Max. Operating Temp. Operating Temp. Range Accuracy Repeatability Wetted Materials WARRANTY Limited Warranty 170 GPM 150 psi 49 °C (120 °F) 0 to 49 °C (32 to 120 °F), optional to 121 °C (250 °F) ±1.5% of full scale ±0.5% Brass, SAN, Noryl, Nylon, Polyethylene, Polypropylene 1 year Easy maintenance Simple operation No need to remove from the line... Mechanical dial display reduce costly downtime APPLICATIONS · Industrial flow systems · Inventory and process control of cold and hot systems · Fuel consumption 109 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | Nutating Disc Series DIMENSIONAL DRAWINGS Models 25, 35 & 70 Models 120 & 170 0 90 Recordall ® 10 T-160 80 20 Badger Meter 64085-001 1-1/2" ® 70 Gallons 30 60 40 50 Dial Display DIMENSIONS IN INCHES WITHOUT REGISTER Meter Model Meter Size Housing Material A: Meter Length BGR-M25 5/8" Bronze 7-1/2" BGR-M35 3/4" Bronze 9" BGR-M70 1" Bronze 10-3/4" BGR-M120 1-1/2" Bronze 12-5/8" BGR-M170 2" Bronze 15-1/4" Note: Other meter sizes and configurations are available. Consult Veris for availability. B: Center to Baseline 1-3/8" 1-3/4" 2-1/4" 2-5/8" 3-3/8" FLOW RATE IN GALLONS Cold Liquids: 32 to 120°F Approx. Weight 1/2 to 25 gpm 5 lbs. 3/4 to 35 gpm 6 lbs. 1 to 70 gpm 12 lbs. 2 to 120 gpm 20 lbs. 2 to 170 gpm 30 lbs. ORDERING INFORMATION Common configurations are shown below with Veris part numbers. For custom configurations, consult Veris for custom configuration part numbers. VERIS PART # MANUF. PART # DESCRIPTION BGR-M25-625LNSA-TS-GAXX M25-625LNSA-TS-GAXX Flow, Disc, 1/2"Line, Connections, Pulse Output with Dial Display BGR-M35-750LNSB-TS-GAXX M35-750LNSB-TS-GAXX Flow, Disc, 3/4"Line, Connections, Pulse Output with Dial Display BGR-M70-100LNSC-TS-GAXX M70-100LNSC-TS-GAXX Flow, Disc, 1"Line, Connections, Pulse Output with Dial Display BGR-M120-150LNSF-TS-GAXX M120-150LNSF-TS-GAXX Flow, Disc, 1-1/2"Line, Connections, Pulse Output with Dial Display BGR-M170-200LNSG-TS-GAXX M170-200LNSG-TS-GAXX Flow, Disc, 2"Line, Connections, Pulse Output with Dial Display Note: Other meter sizes and configurations are available. Consult Veris for availability. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 110 Flow Monitoring | Turbine Meter TURBO SERIES For Pipe Sizes 2", 3", 4", 6", 8", 10", 12", 16" & 20" Turbo Series meters are built for long term service with minimal maintenance. The meter is designed to reduce wear by reducing the friction between the moving parts of the rotor and bearing system, resulting in a longer product life. Water flows into the meter's measuring element, contacting the multi-vaned rotor. The resulting rotor revolutions give flow readings, which are transmitted by magnetic drive couplings. SPECIFICATIONS Flow Range Max. Operating Pressure Max. Operating Temp Accuracy Repeatability WARRANTY Limited Warranty 450: 5 to 450 GPM; 1000: 10 to 1000 GPM (continuous) 150 psi 49 °C (120 °F) ±1.5% of full scale ±0.5% 1 year Increased versatility Optional pulse output transmitter Low flow sensitivity Direct drive mechanism...highest low flow sensitivity Service in-line Easy to service in-line...minimize downtime Easy operation Mechanical dial display Wide flow range Suitable for a wide flow range... application flexibility Reliable bearings Long lasting ceramic bearings APPLICATIONS · Chemical or industrial fluid monitoring · Potable cold water with flow in one direction only 111 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | Turbine Series DIMENSIONAL DRAWING D C F E B B 2" 4" Meter Flanges 2" Elliptical 4" Round Qty. of Bolts 2 8 Length (A) 10" (254 mm) 14" (356 mm) Width (B) 5-27/32" (148 mm) 9" (229 mm) Height (C) 6-1/2" (165 mm) 9-21/32" (245 mm) Flange (D) 25/32" (20 mm) 13/16" (21 mm) Bolt Circle (E) 4-1/2" (114 mm) 7-1/2" (191 mm) Centerline (F) 2-1/16" (52 mm) 4-5/16" (109 mm) Note: Other meter sizes and configurations are available. Consult Veris for availability. 2" NPT (test plug) A 0 90 Recordall ® 10 T-160 80 20 Badger Meter 64085-001 1-1/2" ® 70 Gallons 30 60 40 50 Dial Display 6" 6" Round 8 18" (457 mm) 11" (280 mm) 13-5/16" (338 mm) 7/8" (22 mm) 9-1/2" (241 mm) 5-1/4" (133 mm) 8" 8" Round 8 20" (508 mm) 13-1/2" (343 mm) 15-3/16" (385 mm) 1" (25 mm) 11-3/4" (298 mm) 6-3/8" (162 mm) ORDERING INFORMATION VERIS PART # MANUF. PART # BGR-RT-0300BRWPNSC-TS-GA-XXXX RT-0300BRWPNSC-TS-GA-XXXX BGR-RT-0400BRWPNSC-TS-GA-XXXX RT-0400BRWPNSC-TS-GA-XXXX BGR-RT-0600BRWPNSC-TS-GA-XXXX RT-0600BRWPNSC-TS-GA-XXXX BGR-RT-0800BRWPNSC-TS-GA-XXXX RT-0800BRWPNSC-TS-GA-XXXX Note: Other meter sizes and configurations are available. Consult Veris for availability. DESCRIPTION Flow, Turbine, 3", w Conn, RTR Pulser, Gal, Pulse Output with Dial Display Flow, Turbine, 4", w Conn, RTR Pulser, Gal, Pulse Output with Dial Display Flow, Turbine, 6", w Conn, RTR Pulser, Gal, Pulse Output with Dial Display Flow, Turbine, 8", w Conn, RTR Pulser, Gal, Pulse Output with Dial Display 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 112 Flow Monitoring | Gas Turbine FMloewterM/Metoenritor B142 SERIES/B3000 MONITOR Consistent Accurately Measures Gas Flow Consistent, reliable gas flow measurement Wafer mount Better fit in limited spaces No mating flange design Allows quick and easy installation Durable Reliable performance in harsh environmental conditions Quick response B3000 Lightweight balanced rotor...quick response to changes in flow rate B142 B142 Series gas turbine flow meter offers reliable measurement of natural gas flow rates in boiler systems. The stainless steel housing and tungsten carbide shaft and bearings are durable in any compatible environment. The unique wafer style design is fast and easy to install between two 2" ANSI flanges, reducing costly downtime. The B142 meter is compatible with the B3000 flow monitor for a complete flow monitoring system. The B142 is also compatible with most standard computers, simplifying configuration within existing systems. APPLICATIONS · Monitor natural gas flow in boilers and other industrial systems B142 METER SPECIFICATIONS FLOW MEASUREMENT RANGE B142-20L 7 to 70 ACFM*; 10 to 100 MCFD**; 423 to 4230 MBH 365 pulses per ACF (12900 pulses per m3) B142-20M 14 to 210 ACFM*; 20 to 300 MCFD**; 846 to 12690 MBH 190 pulses per ACF (6710 pulses per m3) B142-20H 35 to 350 ACFM*; 50 to 500 MCFD**; 2115 to 21150 MBH 85 pulses per ACF (3000 pulses per m3) SYSTEM Working Pressure Vacuum to 2220 psig (15.3 MPa) Pressure Drop 3" of water column (7.5 mbar) at maximum rated flow rate (dry air) Pressure Port 1/8" NPTF (plugged) Operating Temperature Range -40 to +165 °C (-40 to +330 °F) Output Voltage 100 mVP-P minimum when used with B111113 magnetic pickup ACCURACY Linearity ±2% of reading over the specified measurement range Uncertainty ±1% of reading when calibration data is entered into an intelligent monitor/transmitter Repeatibility ±0.5% CONSTRUCTION Body and Cartridge 316/316L stainless steel Bearing Mounts 304 stainless steel Set Screws and Pressure Port Plug 316 stainless steel Bearings and Rotor Shaft Tungsten carbide Rotor 410 stainless steel CONNECTIONS Pickup Mates with AN3106A-10SL connector Conduit 1" NPT (25 mm) WARRANTY Limited Warranty 1 year COMPLIANCE INFORMATION Agency Approvals UL913; CSA 22.2 No. 157-92; Class 1 Division 1 Groups C, D Explosion Proof UL1203; CSA 22.2 No. 30-M1986; Class 1 Division 1 Groups C, D Seal ANSI/ISA 12.27.01-2003 AGENCY APPROVALS LASSIFIE C D C ® MET US C US 113 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow MonitoringFlo| wB1M42onSietroierisn/gB3|0B0104M2 oSneritieosr B3000 MONITOR SPECIFICATIONS Input Power OUTPUTS Analog 4 to 20mA Totalizing Pulse Modbus (Advanced Output Models Only) ENGINEERING UNITS Gas Rate Time Totalizer Exponents K Factor Units Auto switching between internal battery and external loop power; Advanced output models include isolation between loop power and other I/O Battery: 3.6VDC lithium "D Cell" gives up to 6 years of service life Loop: 4 to 20 mA, two-wire, 25 mA limit, non-polarity sensitive, 7 Vdc loop loss 4 to 20 mA, two-wire current loop; 25 mA current limit Pulse Type: (selected by circuit board jumper) Opto-isolated (Iso) open collector transistor, Non-isolated open drain FET Maximum Voltage: 28 Vdc Maximum Current Capacity: 100 mA Maximum Output Frequency: 16 Hz Pulse Width: 30 msec fixed Modbus RTU over RS-485, 127 addressable units/2-wire network, 9600 baud, long integer and single precision IEEE754 formats; retrieve: flow rate, job totalizer, grand totalizer, alarm status and battery level; write: reset job totalizer, reset grand totalizer Cubic Feet, Thousand Cubic Feet, Million Cubic Feet, Standard Cubic Feet, Actual Cubic Feet, Normal Cubic Meters, Actual Cubic Meters, Liters Seconds, minutes, hours, days 0.00, 0.0, X1, x10, x100, x1000 Pulses/Gallon, Pulse/cubic meter, pulses/ liter, pulses/cubic foot APPLICATION EXAMPLE Isolation Valve B3000 Series Monitor (converts sine wave from Quicksert to common output formats) 12 B142 Flow Meter Isolation Valve Flow 10 Pipe Diameters (min.) 5 Pipe Diameters (min.) Isolation Valve Bypass Line B142 METER REQUIRED PARTS B142 METER WITH B111113 MAGNETIC PICKUP INSTALLED Dimensional Drawing 3.0" (75 mm) 1.0" NPT (25 mm) 3.1" (79 mm) 3.6" (92 mm) 0.125"NPTF Port (3 mm) 1.8" (46 mm) B142 METER WITH B3000 DISPLAY INSTALLED Dimensional Drawing 4.5" (115 mm) 5.1" (129 mm) 9.0" (229 mm) 2.6" (67 mm) ORDERING INFORMATION VERIS PART # BGR-B142-20L MANUF. PART # B142-20L BGR-B142-20M B142-20M BGR-B142-20H B142-20H BGR-B111113 B111113 BGR-B142-20-150KIT B142-20-150KIT BGR-B30AM-CS B30AM-CS BGR-B30BM-CS B30BM-CS DESCRIPTION Flow, Gas, Quicksert, 2", SS, Low Rate, Pulse Flow, Gas, Quicksert, 2", SS, Med Rate, Pulse Flow, Gas, Quicksert, 2", SS, High Rate, Pulse Flow, Gas, Quicksert, Magnetic Pickup, SS Flow, Gas, Quicksert, Bolt and Gasket Kit Flow Monitor, B3000, Advanced Output Flow Monitor, B3000, Standard Output ++ 2x = 4x B142 B111113 B142-20-150KIT Gas Quicksert Assembly meter magnetic pickup hardware kit (not including the two 2"ANSI flanges) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 114 Flow Monitoring | Vortex Shedding for Steam VN2000 SERIES Accurately Measure Steam Onboard display Provides several units of measure Easy installation Insertion meter and pipe mounting assembly designed for specific pipe sizes Multiple outputs 4-20mA and pulse outputs standard with optional BACnet and Modbus No moving parts or o-rings No parts to service means long product life VN2000 The VN2000 Compact Insertion Vortex Flow Meter measures the flow of steam over a large flow range. The meter includes a mounting assembly alignment pin to simplify the installation. The meter is designed for specific pipe sizes and includes parts for installation. The vortex sensing element is CNC machined out of one piece of solid stainless steel and engineered to stand up to abusive environments inside and outside the pipe. The dual ceramic piezoelectric sensors are bonded inside the vortex element, which is press-fit to the stainless steel insertion bar and completely welded together. There are no internal o-rings or seals of any kind and absolutely no leak paths into the sensors or electronics. These sensors do not touch the process fluid, which gives them an almost unlimited life span. Stainless steel consruction High temperature Vortex assembly is machined from a single piece and stands up to the abusive environment inside the pipe Standard model handles process temperatures up to 400° F (204° C) APPLICATIONS · Steam flow rate or volumetric measurement SPECIFICATIONS Flow Accuracy Repeatability Straight Run Requirements Media Temperature Maximum Pressure Wetted Materials Connections Sensors Units of Measure Measurement interval TRANSMITTER Display Keypad Power Operating Temperature Operating Humidity ±1% of reading ±0.25% of reading Upstream 10 diameters; downstream 5 diameters with one 90° elbow before the meter -250 to 400 °F (-120 to 204 °C) 1000 psi (68.9 bar) Stainless steel 304L "1-1/2 in. carbon steel mounting assembly Sealing assembly: Two ethylene propylene O-rings" Dual piezo vortex sensors Pounds, kilograms, tons, metric tons, cubic feet, cubic meters, gallons, liters Second, minute, hour, day 2×16 characters reflective display, Rotatable display Flow rate: 6 digits with decimal; Totalizer 4 membrane buttons 14 to 36 V DC; loop powered with 4 to 20 mA option, 28V DC max 32 to 140° F (0 to 60° C) 5 to 95% relative humidity non-condensing Analog Output One 4 to 20 mA, 10 to 36V max load, 24-bit resolution Digital Output One min. input resistance 1000 Ohm; Max output frequency = 12.5 Hz; Opto isolator 5 to 24 Vdc Communications Optional via special order: EIA-485 with Modbus RTU or BACnet MS/TP* Enclosure General Purpose Mounting Intergral meter mount; remote mount available via special order* WARRANTY Limited warranty 1 year *Other meter sizes and configurations are available. Consult Veris for availability. 115 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | VN2000 Series VN2000 METER WITH 1-1/2" NPT CONNECTION Dimensional Drawing A C B D Alignment pin H E Meter Meter inserted into pipe SATURATED STEAM FLOW RATES (LBS/HR) PIPE LINE SIZE 5 PSIG 0.0486 LB/FT3 50 PSIG 0.1503 LB/FT3 100 PSIG 0.2577 LB/FT3 58.38 (min.) 124.0 (min.) 177.7 (min.) 2" 1019 (max.) 3152 (max.) 5404 (max.) 128.6 (min.) 273.2 (min.) 391.4 (min.) 3" 2244 (max.) 6945 (max.) 11905 (max.) 221.5 (min.) 470.5 (min.) 674.0 (min.) 4" 3865 (max.) 11959 (max.) 20501 (max.) 502.6 (min.) 1068 (min.) 1530 (min.) 6" 8771 (max.) 27140 (max.) 46525 (max.) 870.4 (min.) 1849 (min.) 2649 (min.) 8" 15188 (max.) 46997 (max.) 80564 (max.) Note: Other meter sizes and configurations are available. Consult Veris for availability. H 2" (51 mm) 3" (76 mm) 4" (102 mm) 6" (152 mm) 8" (203 mm) A 5" (127 mm) 5" (127 mm) 5" (127 mm) 5" (127 mm) 5" (127 mm) B 11" (279 mm) 11" (279 mm) 12" (305 mm) 13" (330 mm) 14" (356 mm) C 16" (406 mm) 16" (406 mm) 17" (432 mm) 18" (457 mm) 19" (483 mm) D 15" (381 mm) 14.5" (368 mm) 15" (381 mm) 15" (381 mm) 15" (381 mm) E 1.25" (32 mm) 1.25" (32 mm) 1.25" (32 mm) 1.25" (32 mm) 1.25" (32 mm) 150 PSIG 0.3614 LB/FT3 222.7 (min.) 7580 (max.) 490.5 (min.) 16698 (max.) 844.7 (min.) 28755 (max.) 1917 (min.) 65256 (max.) 3319 (min.) 112999 (max.) 200 PSIG 0.4688 LB/FT3 264.9 (min.) 9832 (max.) 583.5 (min.) 21662 (max.) 1005 (min.) 37302 (max.) 2280 (min.) 74653 (max.) 3949 (min.) 146586 (max.) 300 PSIG 0.6481 LB/FT3 328.7 (min.) 13592 (max.) 724.2 (min.) 29944 (max.) 1247 (min.) 51565 (max.) 2830 (min.) 117021 (max.) 4900 (min.) 202637 (max.) 400 PSIG 0.8613 LB/FT3 397.4 (min.) 18064 (max.) 875.5 (min.) 39797 (max.) 1508 (min.) 68531 (max.) 3421 (min.) 155525 (max.) 5924 (min.) 269310 (max.) ORDERING INFORMATION VERIS PART # MANUF. PART # BGR-VCA020-C-S-S-W-V-E-WW-SSSG VCA020-C-S-S-W-V-E-WW-S-S-S-G BGR-VCA030-C-S-S-W-V-E-WW-SSSG VCA030-C-S-S-W-V-E-WW-S-S-S-G BGR-VCA040-C-S-S-W-V-E-WW-SSSG VCA040-C-S-S-W-V-E-WW-S-S-S-G BGR-VCA060-C-S-S-W-V-E-WW-SSSG VCA060-C-S-S-W-V-E-WW-S-S-S-G BGR-VCA080-C-S-S-W-V-E-WW-SSSG VCA080-C-S-S-W-V-E-WW-S-S-S-G Note: Other meter sizes and configurations are available. Consult Veris for availability. DESCRIPTION Flow,Vortex,2",Steam,Insertion,4-20mA/Pulse Flow,Vortex,3",Steam,Insertion,4-20mA/Pulse Flow,Vortex,4",Steam,Insertion,4-20mA/Pulse Flow,Vortex,6",Steam,Insertion,4-20mA/Pulse Flow,Vortex,8",Steam,Insertion,4-20mA/Pulse HQ0007945.A 0221 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | Monitor: Local Display, Output & BTU FC-5000 SERIES Displays Flow Rate, Flow Total and Energy Enhanced viewing Large, backlit graphical display Intuitive navigation Integrated softkeys and full numeric keypad Programmable scaled outputs Outputs transmit rate, total or temperature data via dedicated output channels Programmable relays Enables alarms or totalizing output capabilities for rates, totals and temperaturesr FC-5000 The Badger Meter® FC-5000 is a microprocessor-driven device designed for energy/BTU and flow monitoring. The FC-5000 BTU Monitor is compatible with the complete line of Badger Meter industrial flow meters and temperature sensors, creating a solution to monitor hydronic energy usage, flow rate and totals. Many years of experience in the industrial market has allowed Badger Meter to incorporate features indispensable in control operations SPECIFICATIONS FC-5000 Series Power Supply Input Range 10 to 40Vdc, 9 to 28Vac RMS (50 to 60 Hz) Max. Power Consumption 8 W (power supply must provide 8 W min.) Additional Parameters Isolated from power ground Over-voltage, transient and reverse polarity protected Flow Meter Inputs Independent Channels 1 Input Range 0.3 Hz to 10 kHz Configuration Options Square wave 0 to 30V pulse with 2.5V threshold, Sine wave, zero-centered with 45 mV threshold, Configurable debounce Excitation Output 12 Vdc source Voltage Low: -0.3 to 1.85 Vdc High: 2.5 to 25 Vdc Impedance Pullup to 12 Vdc Vdc Current ±50 mA, short circuit current Response 100 µs/3.5 ms min pulse (high/low speed) Temperature Inputs Independent Channels 2 RTD Specifications 50 µA/1000 µA excitation current source 2, 3 and 4-wire compatible (Platinum, 100 and 1000 RTDs, optional two-point or customizable calibration configuration) Callendar-Van Dusen coefficients Thermistor Specs Type II thermistors or customizable calibration configuration, Steinhart-Hart coefficients Plug & play terminals Easy, user-friendly installation Rugged application Robust enclosure, keypad and mechanical relays APPLICATIONS · Interfacing and displaying sensor data · Energy monitoring, communication, and management Scaled Outputs Independent Channels Analog Output (Option A) Frequency Output (Option F) Additional Parameters Digital I/O Independent Channels Additional Parameters CALCULATIONS Flow Calculation BTU Calculation 2 Configurable to 0 to 5V, 0 to 10V or 4 to 20 mA; Uncertainty: ±0.1% of reading; 16-bit resolution (0 to 10V and 4 to 20 mA), 15-bit resolution (0 to 5V); 200 ms, 90-10% step response; Sourcing analog output signal TTL, 1 to 4000 Hz, square wave; Uncertainty: ±0.01% reading; Resolution: 0.01 Hz Isolated from power ground Over-voltage, transient and reverse polarity protected Output is multiplexed on the process out pins 6 Isolated from power ground Over-voltage, transient and reverse polarity protected 0 to 30V as input Debounce 0 to 5V, TTL, 200 ms 90-10% step response, driving < 0.1 uF Uncertainty: ± 0.01% Adjustable FIR/IIR filtering Meets EN 1434 requirements 117 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | FC-5000 Series SPECIFICATIONS (CONT.) FC-5000 Series RELAY OUTPUTS Configuration (Option C) Two Form C mechanical relays Configuration (Option A) One Form C mechanical relay One Form A solid state relay Form C Relay Load: Resistive Rated carry current: 5A (N.C. or N.O.) Max. switching voltage: 250 Vac, 30 Vdc Min. permissible load: 10 mA at 5 Vdc Coil rating: 5 to 24 Vdc Life expectancy: 5,000,000 operations Form A Relay (N.O. SPST) Switching speed: On (0.25 ms), Off (0.02 ms) Current rating (IO): 1A Max. output voltage (VO): 60V Output On-Resistance (R(ON)): 0.5 @ IF = 5 mA, IO = 1 A Output Withstand Voltage (VO(OFF)): 60-65V @ VF = 0.8V, IO = 250 µA, TA = 77° F (25° C) Additional Parameters Isolated coil drivers Over-voltage, transient and reverse polarity protected NETWORK COMMUNICATIONS Protocols Modbus RTU, Modbus ASCII or BACnet Physical Layer EIA-485 (RS-485) Baud Rates 1200 to 115.2K Additional Parameters Two-wire (half-duplex) Over-voltage/ESD Protection Isolated from power ground USB COMMUNICATIONS USB (Host) Type A receptacle (currently not supported) USB (Device) Mini-B receptacle (used for field updates) Additional Parameter Over-voltage/ESD/transient protected DISPLAY/USER INTERFACE Keypad Membrane overlay, domed tactile response keys, keypad interface is protected from ESD Display 128 × 64 pixel LCD graphical display, LED backlit Additional Parameter Protected from EMI/RFI PANEL MOUNT Dimensional Drawing C B D A E A Panel Cutout ENVIRONMENTAL RATINGS Pollution Degree 2 Altitude Up to 2000 m (6561 ft) Over-Voltage Rating Category II Ambient Temp. 32 to 130° F (0 to 55° C) Storage Temp. -40 to 160° F (-40 to 70° C) Humidity 0 to 85%, non-condensing WEIGHTS (APPROX.) Panel Mount 1.25 lb (0.57 kg) Wall Mount (Including Unit) 4.54 lb (2.06 kg) OPERATOR FUNCTIONS Operator Functions Unlatch relays, reset totalizers, unlatch relays and reset totalizers PARAMETERS Max. Displayed Digits Rates: Max 8 (7 with decimal) Totals: Max 9 (8 with decimal) Resolution/Display Precision Configurable, 0 to 4 Volumetric Flow Rate Units Seconds (S), Minute (MIN), Hour (H), Day (D), Volumetric Flow Total Units US Gallons (US GAL), Imperial Gallons (I GAL), Mega US Gallons (US MGAL), Mega Imperial Gallons (I MGAL), Liters (L), Mega Liters (ML), Cubic Meters (M3), Cubic Feet (FT3), Acre Feet (AC-FT), Oil Barrels (OBBL), Liquid Barrels (LBBL), US Ounces (US OZ), Imperial Ounces (I OZ), Custom (user-specified) Energy Units kBTU, BTU, KW, TONS (RT), Custom (user-defined) Temperature Units ° F (Fahrenheit), ° C (Celsius), R (Rankine) or K (Kelvin) WARRANTY Limited Warranty 1 year AGENCY APPROVALS Aprovals CE Marked for Low Voltage Directive and RoHS CSA Marked per Class C225286 and C225206, Process Control Equipment CSA C22.2 No. 61010-1-12, General requirements CAN/CSA-C22.2 No. 61010-1-12 Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General requirements -- Tri-national standard with UL 61010-1 and ANSI/ISA61010-1 (82.02.01) WALL MOUNT D Dimensional Drawing F C H G A E B Note: Mounting clips can accommodate a maximum panel thickness of 1.5 in. (38.1 mm) A HEIGHT Panel Cutout 2.65 (67.31) FC-5000 Unit 3.50 (89.00) Wall Mount Unit 9.38 (238.25) Note: All measurements: in. (mm) B WIDTH 5.40 (137.16) 6.22 (158.00) 9.38 (238.25) C DEPTH 3.07 (78.00) 4.88 (123.95) D WIDTH 5.38 (136.65) 8.00 (203.20) E HEIGHT 2.54 (64.52) 9.56 (242.83) B F WIDTH 6.00 (152.40) G H HEIGHT HOLE DIA. 8.75 (222.25) 0.31 (7.87) CONTINUED NEXT PAGE 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 118 Flow Monitoring | FC-5000 Series FC-5000 SERIES, CONTINUED OPERATION Input signal--in the form of sine waves or pulses from open collector transistors or dry contact closures--can be scaled to any unit of measure for totalization and instantaneous rate-of-flow indication. Energy rate and flow totals are examples of parameters that can be viewed on the panel display or through communications protocols such as BACnet or Modbus. Two temperature sensor inputs can be configured to read RTDs or thermistors and are fully customizable to adapt to application needs. When used in conjunction with fluid flow, hydronic energy rates and total usage are achieved, while conforming to EN1434 standards. Additionally, dedicated analog or frequency output channels provide scaled outputs that are assignable to parameters such as energy rate, total and temperature. A user defined damping function can be applied for improved stability of the flow readings. VIEWING CAPABILITIES Single Display Dual Display · Flow Rate · Flow Total · Energy/BTU Rate · Energy/BTU Total · Flow Rate and Flow Total · Energy/BTU Rate and Energy/BTU total EIA-485 (RS-485) NETWORK All FC-5000 BTU Monitors come equipped with an EIA-485 (RS-485) physical layer, and use BACnet or Modbus RTU protocols, selectable and programmed in the firmware. Up to 255 FC-5000 products can be run on a single daisy-chain network and be individually queried for flow/energy rate, positive flow/energy accumulator, supply temperature, return temperature and other information. Daisy-chained units ORDERING INFORMATION FC-5000 Flow Display, Frequency Output Frequency Flow Output Display BGR FC5 FD Sensor Inputs Scaled Outputs F Relay Outputs F Digital I/O 6 Comm. A Mount Example: BGR - FC5 - FD - P0 = 1 Pulse P3 = 2 Pulse* P3 - F F = 2 Frequency Outputs A = 1 Form C Relay/ 1 Form A Relay C = 2 Form C Relays* *Special order. A 6 A- P A = EIA-485 (RS-485), Modbus, BACnet, USB P = Panel Mount W = Wall Mount (includes NEMA 4X IP67 rated enclosure) FC-5000 Flow Display, Analog Output Frequency Flow Output Display BGR FC5 FD Sensor Inputs Scaled Outputs A Relay Outputs F Digital I/O 6 Comm. A Mount Example: BGR - FC5 - P1 = 1 Pulse P2 = 2 Pulse* A = 2 Analog Outputs FD - P2 - A A 6 A - A = 1 Form C Relay/ 1 Form A Relay C = 2 Form C Relays* W *Special order. A = EIA-485 (RS-485), Modbus, BACnet, USB P = Panel Mount W = Wall Mount (includes NEMA 4X IP67 rated enclosure) 119 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | 02 Series 02 SERIES Complete meter Electronic Flow Meter with Scaled Pulse Output Includes turbine assemby, microprocessor and LCD readout Easy installation Lightweight, compact design Remote monitor Battery powered Remote monitor option to connect Display powered by two AAA to an external system (NPN Open alkaline batteries that are easy to Collector Pulse) replace, with the meter installed 02 Series The FLOMEC® 02 Series is a lightweight, accurate and reliable turbine meter. Choose the 02 Series for thin viscosity fluid applications. · Aluminum or nylon housing · Virtually maintenance free · Display powered by two AAA batteries · Offers one pulse per unit (gallons or liters) SPECIFICATIONS Totalization Batch (resettable to measure flow during a single use) and Cumulative (non-resettable, to provide continuous measurement) APPLICATIONS · Building automation (chillers) · Consumption baselining DIMENSIONAL DRAWING 4.00" (101.6 mm) Fitting Size / Fitting Type Flow Rate Accuracy (% of Reading) Pressure Rating Operating Temperature Range Pulse Out Description Pulse Duration Pulse Amplitude Scaling Cable Length Wetted Materials (Aluminum) Wetted Materials (Nylon) Limited Warranty Approvals 1 inch / BSPT (female) 1 inch / NPT (female) 3 to 30 GPM 11 to 113 LPM ± 5.0% 150 PSIG / 10.3 BAR 14 to 130 °F (-10 to 55 °C) Open Collector (also known as NPN or Current Sinking) 250 msec 5 to 30 Vdc One pulse per gallon or liter 5 ft. (1.5 m) Housing: Aluminum Bearings: Ceramic Shaft: Tungsten carbide Rotor: Nylon Rings: 316 stainless steel Signal generator: Ferrite Housing: Nylon Bearings: Ceramic Shaft: Tungsten carbide Rotor: Nylon Rings: 316 stainless steel Signal generator: Ferrite 2 years CE 2.41" (61.21 mm) 2.14" (54.36 mm) INTERNAL PULL-UP RESISTOR Pull-up Resistor 5 to 30 Vdc V+ Interface Equipment Red (pulse) INPUT Black (common) GND Note: Some interface devices may not have an internal pull-up resistor. Use a minimum 820 resistor if necessary. ORDERING INFORMATION VERIS PART # FLO-02N31GM FLO-02N12LM FLO-02A31GM FLO-02A12LM MANUF. PART # 02N31GM 02N12LM 02A31GM 02A12LM DESCRIPTION Nylon flow meter, digital pulse, 1-inch NPT inner, gallons, display Nylon flow meter,digital pulse, 1 inch BSPT inner, liters, display Aluminum flow meter, digital pulse, 1-inch NPT inner, gallons, display Aluminum flow meter, digital pulse, 1-inch BSPT inner, liters, display Note: FLOMEC is a registered trademark of Great Plains Industries, Inc., the manufacturer of the devices shown. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 120 Flow Monitoring | Electromagnetic Flow Meter QSE SERIES Electromagnetic Flow Meter Economical Low investment and operating costs Highly accurate ± 0.5% accuracy of reading (from 0.25 fps to 15 fps) Modified bore Durable Slightly modified bore permits unobstructed flow, minimizes flow disturbances and straight pipe requirements Non-intrusive, no moving parts to wear out, maintenance, repair costs low and tolerates high flows without damage QSE Series 7 line sizes ½", ¾", 1", 1-½", 2", 3" and 4" The FLOMEC® QSE Mag Series is a dependable, highly accurate electromagnetic flow meter designed for flow and usage monitoring in commercial applications. The Noryl® housing and flow tube offer a lightweight, easy-to-install mag meter that is resistant to heat (210 °F / 99 °C) and is compatible with many water-based liquid solutions. The QSE Mag Meter monitors flow rate and total flow in a wide variety of applications including HVAC and water reclamation. Meters without display are configured wirelessly using the FLOMEC app. The app is available through the Google PlayTM store, for Android systems only. APPLICATIONS · HVAC · EMS (Energy Management Systems) · BAS (Building Automation Systems) · Chilled water Wireless Configure and monitor meters without display through Android app · Domestic water (hot and cold · Energy sub-metering (BTU hot and cold) · Process (blow down, make up, boiler feed, etc.) SPECIFICATIONS Fitting Size/Fitting Type Recommeded Plastic Flange Bolt Torque Pipe Sizes Pressure Rating Accuracy Operating Temperature Range Ambient Temperature Range Power Supply Consumption Wetted Materials NPT, BSP 1/2" to 2" - NPT (male), BSP (male) (Rc thread) 3" and 4" 150# ANSI flanged, polymer 25 ft.-lbs. (33.89 Nm) ½", ¾", 1", 1-½", 2", 3", 4" 150 PSI @ 73 °F (10 BAR @ 23 °C) ±0.5% of reading between 0.25 fps and 15 fps (reference owner's manual for complete accuracy specifications) ½" to 2": 32 to 210 °F (0 to 98 °C) 3" to 4": 32 to 180 °F (0 to 82 °C) 0 to 140 °F (-18 to 60 °C) Externally powered Voltage supply (min.): 12 Vdc or Vac Voltage supply (max.): 30 Vdc or Vac Max. current consumption: 150mA Body: Noryl Electrodes: 316L SS Seals: NBR o-rings Frequency Range (all sizes) Calibration Report Limited Warranty Approvals 10 Hz min. 3,000 Hz max. (with blind pulse out) Standard NIST available 2 years NEMA 6P (pending), IP67, CE, NIST, NSF, Canadian Standards Association Note: FLOMEC is a registered trademark of Great Plains Industries, Inc., the manufacturer of the devices shown. 121 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Flow Monitoring | QSE Series ORDERING INFORMATION VERIS PART # MANUF. PART # DESCRIPTION FLOW WITH DISPLAY FLO-QSE05NPT42XXXA QSE05NPT42XXXA Noryl,MagFlowmeter,Display,pulse+4-20mA-out,1/2inch,NPT_outer-thd FLO-QSE05BSP42XXXA QSE05BSP42XXXA Noryl,MagFlowmeter,Display,pulse+4-20mA-out,1/2inch,BSP_outer-thd FLO-QSE07NPT42XXXA QSE07NPT42XXXA Noryl,MagFlowmeter,Display,pulse+4-20mA-out,3/4inch,NPT_outer-thd FLO-QSE07BSP42XXXA QSE07BSP42XXXA Noryl,MagFlowmeter,Display,pulse+4-20mA-out,3/4inch,BSP_outer-thd FLO-QSE10NPT42XXXA QSE10NPT42XXXA Noryl,MagFlowmeter,Display,pulse+4-20mA-out,1inch, NPT_outer-thd FLO-QSE10BSP42XXXA QSE10BSP42XXXA Noryl,MagFlowmeter,Display,pulse+4-20mA-out,1inch, BSP_outer-thd FLO-QSE15NPT42XXXD QSE15NPT42XXXD Noryl,MagFlowmeter,Display,pulse+4-20mA-out,1-1/2inch,NPT_outer-thd FLO-QSE15BSP42XXXD QSE15BSP42XXXD Noryl,MagFlowmeter,Display,pulse+4-20mA-out,1-1/2inch,BSP_outer-thd FLO-QSE20NPT42XXXD QSE20NPT42XXXD Noryl,MagFlowmeter,Display,pulse+4-20mA-out,2inch,NPT_outer-thd FLO-QSE20BSP42XXXD QSE20BSP42XXXD Noryl,MagFlowmeter,Display,pulse+4-20mA-out,2inch,BSP_outer-thd FLO-QSE30FAP42XXXB QSE30FAP42XXXB Noryl,MagFlowmeter,Display,pulse+4-20mA-out,3inch,flange FLO-QSE40FAP42XXXC QSE40FAP42XXXC Noryl,MagFlowmeter,Display,pulse+4-20mA-out,4inch,flange BTU WITHOUT DISPLAY* FLO-QSE05NPTQBQ11A QSE05NPTQBQ11A Noryl,MagBTUFlowmeter,Modbus+pulse-out,1/2inch,NPT_outer-thd FLO-QSE05BSPQBQ11A QSE05BSPQBQ11A Noryl,MagBTUFlowmeter,Modbus+pulse-out,1/2inch,BSP_outer-thd FLO-QSE07NPTQBQ11A QSE07NPTQBQ11A Noryl,MagBTUFlowmeter,Modbus+pulse-out,3/4inch,NPT_outer-thd FLO-QSE07BSPQBQ11A QSE07BSPQBQ11A Noryl,MagBTUFlowmeter,Modbus+pulse-out,3/4inch,BSP_outer-thd FLO-QSE10NPTQBQ11A QSE10NPTQBQ11A Noryl,MagBTUFlowmeter,Modbus+pulse-out,1inch,NPT_outer-thd FLO-QSE10BSPQBQ11A QSE10BSPQBQ11A Noryl,MagBTUFlowmeter,Modbus+pulse-out,1inch,BSP_outer-thd FLO-QSE15NPTQBQ11D QSE15NPTQBQ11D Noryl,MagBTUFlowmeter,Modbus+pulse-out,1-1/2inch,NPT_outer-thd FLO-QSE15BSPQBQ11D QSE15BSPQBQ11D Noryl,MagBTUFlowmeter,Modbus+pulse-out,1-1/2inch,BSP_outer-thd FLO-QSE20NPTQBQ11D QSE20NPTQBQ11D Noryl,MagBTUFlowmeter,Modbus+pulse-out,2inch,NPT_outer-thd FLO-QSE20BSPQBQ11D QSE20BSPQBQ11D Noryl,MagBTUFlowmeter,Modbus+pulse-out,2inch,BSP_outer-thd FLO-QSE30FAPQBQ12B QSE30FAPQBQ12B Noryl,MagBTUFlowmeter,Modbus+pulse-out,3inch,Flange FLO-QSE40FAPQBQ12C QSE40FAPQBQ12C Noryl,MagBTUFlowmeter,Modbus+pulse-out,4inch,Flange *Products without display are configured wirelessly using the FLOMEC app. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 122 HUMIDITY MONITORING Veris offers a complete line of sensors for commercial/industrial relative humidity monitoring applications. Our sensors include a factory-calibrated humidity sensing element, fully replaceable (on deluxe models) for long-term cost savings. All humidity sensors provide superior accuracy, excellent stability, and easy serviceability. Accuracy choices include 2%, 3%, and 5%, with 1% or 2% NIST traceability available on selected units. LCD displays are available on some models for easy viewing. Add temperature sensing for greater application flexibility. MODEL HW2 HW2xP HEW HD/HO HN/HP HED HS DESCRIPTION Wall Mount Analog Humidity Sensors Wall Mount Protocol Humidity Sensors Economy Wall Humidity Sensors Deluxe Duct and Outdoor Humidity Sensors Specialty Humidity Sensors Economy Duct Humidity Sensors Replaceable Humidity Elements PAGE 125 127 129 131 133 135 137 HUMIDITY SENSOR SELECTION GUIDE FEATURES/OPTIONS Analog Output Protocol Communication NIST Traceable Accuracy Down to 1% Resistive Temperature Sensing LCD Display Touchscreen Display WALL MOUNT HW2, HEW pages 125, 129 HW2xP page 127 HW2, HW2xP pages 125, 127 HW2 page 125 HW2L, HW2xPL pages 125, 127 HW2T, HW2xP pages 125, 127 DUCT MOUNT HD, HED pages 131, 135 HD page 131 HD page 131 OUTDOOR MOUNT HO page 131 HO page 131 HO page 131 PROBE HN/HP page 133 HN/HP page 133 HN/HP page 133 123 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com TOUCHSCREEN DISPLAY FOR OPTIMAL ENVIRONMENTAL CONTROL HW2 Series Wall Humidity Sensors APPLICATIONS » Control HVAC systems for improved comfort and energy savings » Facilitate ASHRAE compliance standards for environmental control and indoor air quality » Flexible housing can also be used to measure Temperature, CO2 and VOC TOUCHSCREEN LCD NON-DISPLAY FEATURES IINTERCHANGEABLE FIELDREPLACEABLE ELEMENT Fully interchangeable element (1%-2% accuracy) with no calibration required! Field replaceable to maintain accuracy while minimizing downtime MODERN AESTHETIC WITH THREE DISPLAY OPTIONS Touchscreen, LCD, or Non-Display MULTI-SENSOR FLEXIBILITY Humidity and temperature sensors included with all HW2 Series sensors Save time in the field and stock fewer devices Suitable for new construction and retrofit/remodel EASY TO INSTALL Large wiring terminals and snap-on covers simplify installation and servicing Calibration-free interchangeable NIST traceable HS element 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 124 Humidity Monitoring | Analog Humidity Sensors HW2 SERIES Wall Mount Humidity Sensors Sensor element Thin-film capacitive sensor element recovers from 100% saturation Field replaceable Replace element in the field... maintain accuracy and minimize downtime HW2Txxxx HW2Lxxxx HW2Xxxxx The HW2 Series of humidity sensors for living space is a flexible multisensor platform for use with BAS controllers designed to accept 4 to 20mA, 0 to 5Vdc or 0 to 10Vdc outputs. HW2 Series sensors are available with three user interface options: touchscreen, LCD with three buttons and blank. Humidity and temperature sensors are included with all HW2 Series sensors. SPECIFICATIONS OPERATING ENVIRONMENT Input Power Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz Analog Output Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V Operating Temperature Range 0 to 50 °C (32 to 122 °F) Operating Humidity Range 0 to 95% RH non-condensing Housing Material High-impact ABS plastic Terminal Block Torque 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) RH TRANSMITTER HS Sensor Thin-film capacitive, replaceable Accuracy ±2% from 10 to 80% RH @ 25°C (77 °F) Hysteresis 1.5% typical Stability ±1% @ 20°C (68 °F) annually for 2 years Output Range 0 to 100% RH Temperature Coefficient ±0.1% RH/°C above or below 25 °C (77 °F) typical TEMPERATURE TRANSMITTER OPTION Sensor Type Solid state, integrated circuit Accuracy ±0.2 °C (±0.4 °F) typical Resolution 0.1 °C (0.1 °F) Range 0 to 50 °C (32 to 122 °F) DISPLAY MODELS Touchscreen 61 mm (2.4 in), color, backlit, capacitive, 240x300 px Setpoint: 0-10 Vdc. Temperature, humidity or fan speed selectable Timeout override: Display timeout* Lockout override: Touchscreen/button lockout* 52mm (2.05 in), segmented with 3 buttons Setpoint: 0-10Vdc. Temperature, humidity LCD or fan speed selectable Timeout override: Display timeout* Lockout override: Touchscreen/button lockout* Interchangable element Fully interchangeable element to 1% or 2% accuracy with NIST calibration certificate...no calibration Easy to install Large wiring terminals on baseplate and snap-on covers with security screw simplify installation and service Flexible Polarity insensitive, two-wire 4 to 20 mA or 3-wire 0-5/0-10 Vdc versions...flexible systems compatibity...save time in the field, stock fewer devices Calibration free Calibration-free interchangeable NIST traceable HS element APPLICATIONS · Controlling HVAC systems for improved comfort and energy savings · Museums, schools, printing shops, and other locations requiring humidity control · Facilitating compliance with ASHRAE standards for environmental control and indoor air quality SETPOINTS** Temperature Setpoint Humidity Setpoint Fan Speed Setpoint OVERRIDE Override Button WIRING TERMINALS Terminal Blocks Screw Terminal Torque WARRANTY Limited Warranty COMPLIANCE INFORMATION Agency Approvals 0 to 10V output Scale: 10 to 35 °C (50 to 95 °F) / 0 to 50 °C (32 to 122 °F) 0 to 10V output Scale: 0 to 100% RH 0 to 10V output Off 0V, Low 3.3V, Med. 6.7V, High 10.0V Display models feature momentary-to-ground override button Screw terminals, 18-24 AWG 0.2 N-m (2.0 in-lbF) max. 5 years UL 916, European conformance CE: EN61000-6-2 EN61000-6-3 EN61000 Series - industrial immunity EN 61326-1 FCC Part 15 Class B, REACH, RoHS, RCM (Australia), ICES-003 (Canada) *DIP switch selectable.. ** One setpoint type is selectable via DIP switch on display models only. 125 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING Humidity Monitoring | HW2 Series USER INTERFACE TYPES 115 (4.5) 85 24 (3.3) (0.9) Touchscreen LCD with Buttons Blank HW2L/HW2T DISPLAY MODELS WITH TEMP TRANSMITTER HW2L/HW2T DISPLAY MODELS WITH RTD/THERMISTOR Wiring Diagram Wiring Diagram OVERRIDE SETPOINT OUT RH OUT TEMP OUT COMMON POWER (+24) 10 9 8 7 6 5432 1 OVERRIDE SETPOINT OUT RH OUT RTD/THERMISTOR OUT RTD/THERMISTOR OUT COMMON POWER (+24) 10 9 8 7 6 5432 1 HW2X WITH TEMP TRANSMITTER Wiring Diagram HW2X WITH RTD/THERMISTOR Wiring Diagram RH OUT TEMP OUT COMMON POWER (+24) 5432 1 RH OUT RTD/THERMISTOR OUT RTD/THERMISTOR OUT COMMON POWER (+24) 5432 1 ORDERING INFORMATION HW2 User Interface Output RH Accuracy* Temperature T = Color touchscreen L = 3-button LCD display X = None A = Analog output 2 = 2% A = Transmitter only C = 1000 PT RTD D = 10K T2 thermistor G = 10K CPC thermistor** H = 10K T3 thermistor K = 10K curve G/11K shunt M = 20K NTC thermistor N = 1.8K TAC thermistor R = 10K curve G*** Example: HW2 T A 2 A * Replaceable 1% with NIST certificate, 2% with NIST certificate and 2% elements available. ** Available in HW2XA2G only. *** Available in HW2XA2R only. REPLACEABLE RH ELEMENTS MODEL RH ACCURACY HS1N ±1% HS2N ±2% HS2X ±2% CALIBRATION CERTIFICATE X X DESCRIPTION Replaceable RH sensor, 1% with NIST certification Replaceable RH sensor, 2% with NIST certification Replaceable RH sensor, 2% Replaceable RH Element 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 126 Humidity Monitoring | Protocol Humidity Sensors HW2 PROTOCOL SERIES Wall Mount Humidity Sensors BACnet & Modbus Field replaceable Embedded BACnet and Modbus communication protocols...easy systems integration Replace element in the field... maintain accuracy and minimize downtime HW2Txxxx HW2Lxxxx HW2Xxxxx The HW2 Protocol Series of humidity sensors for living space is a flexible multisensor platform for use with BAS controllers designed to accept BACnet and Modbus outputs. HW2 Protocol Series sensors are available with three user interface options: touchscreen, LCD with three buttons and blank. Humidity and temperature sensors are included with all HW2 Protocol Series sensors. SPECIFICATIONS OPERATING ENVIRONMENT Input Power Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz Protocol Output BACnet or Modbus via RS-485, selectable Operating Temperature Range 0 to 50 °C (32 to 122 °F) Operating Humidity Range 0 to 95% RH non-condensing Housing material High-impact ABS plastic Terminal Block Torque 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) RH TRANSMITTER HS Sensor Thin-film capacitive, replaceable Accuracy ±2% from 10 to 80% RH @ 25°C (77 °F) Hysteresis 1.5% typical Stability ±1% @ 20°C (68 °F) annually for 2 years Output Range 0 to 100% RH Temperature Coefficient ±0.1% RH/°C above or below 25 °C (77 °F) typical TEMPERATURE TRANSMITTER Sensor Type Solid state, integrated circuit Accuracy ±0.2 °C (±0.4 °F) typical Resolution 0.1 °C (0.1 °F) Range 0 to 50 °C (32 to 122 °F) DISPLAY MODELS Touchscreen 61 mm (2.4 in), color, backlit, capacitive, 240x300 px Setpoint: Temperature, humidity or fan speed selectable Timeout override: Display timeout Lockout override: Touchscreen/button lockout 52mm (2.05 in), segmented with 3 buttons Setpoint: Temperature, humidity or LCD fan speed selectable Timeout override: Display timeout Lockout override: Touchscreen/button lockout Sensor element Easy to install Thin-film capacitive sensor element recovers from 100% saturation Large wiring terminals on baseplate and snap-on covers with security screw simplify installation and service Interchangable element Fully interchangeable element to 1% or 2% accuracy with NIST calibration certificate...no calibration Calibration free Calibration-free interchangeable NIST traceable HS element APPLICATIONS · Controlling HVAC systems for improved comfort and energy savings · Museums, schools, printing shops, and other locations requiring humidity control · Facilitating compliance with ASHRAE standards for environmental control and indoor air quality SETPOINTS Temperature Setpoint Humidity Setpoint Fan Speed Setpoint OVERRIDE Override Button WIRING TERMINALS Terminal Blocks Screw Terminal Torque WARRANTY Limited Warranty COMPLIANCE INFORMATION Agency Approvals Scale: 10 to 35 °C (50 to 95 °F) / 0 to 50 °C (32 to 122 °F) Scale: 0 to 100% RH Off, Low, Medium, High Display models feature momentary-to-ground override button Screw terminals, 18-24 AWG 0.2 N-m (2.0 in-lbF) max. 5 years UL 916, European conformance CE: EN61000-6-2 EN61000-6-3 EN61000 Series - industrial immunity EN 61326-1 FCC Part 15 Class B, REACH, RoHS, RCM (Australia), ICES-003 (Canada) 127 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING Humidity Monitoring | HW2 Protocol Series USER INTERFACE TYPES 115 (4.5) 85 24 (3.3) (0.9) WIRING DIAGRAM Touchscreen LCD with Buttons Blank RS-485 (+) RS-485 (-) GROUND POWER (+24) 5432 1 ORDERING INFORMATION MODEL USER INTERFACE RH* TEMP SETPOINT HW2TP2A Touchscreen X X X HW2LP2A LCD / 3 Buttons X X X HW2XP2A Blank X X * Replaceable 1% with NIST certificate, 2% with NIST certificate and 2% elements available. OVERRIDE X X REPLACEABLE RH ELEMENTS MODEL RH ACCURACY HS1N ±1% HS2N ±2% HS2X ±2% CALIBRATION CERTIFICATE X X DESCRIPTION Replaceable RH sensor, 1% with NIST certification Replaceable RH sensor, 2% with NIST certification Replaceable RH sensor, 2% Replaceable RH Element 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 128 Humidity Monitoring | Economy Wall Humidity Sensors HEW SERIES 2%, 3%, and 5% Accuracies RH & temperature Low profile Monitor humidity and Housing is low-profile...perfect temperature with a single device... for schools and museums reduces installation costs Sensor options Semiconductor temperature transmitter, or popular thermistor/RTD sensors available HEW HEW Economy Series wall mount humidity transmitters offer high performance in an easy to install housing at an affordable price. The thin-film capacitive sensor element provides high accuracy and performance, great long-term stability, and full recovery from saturation. Temperature sensing options are also available. APPLICATIONS · HVAC economizer control · Managing energy systems The wall housing was created using sophisticated thermal analysis techniques for optimum airflow. It is ideal for schools and other applications requiring exceptional durability and a discrete appearance. All Economy models come with a standard one-year warranty. · Facilitating ASHRAE standards for environmental control SPECIFICATIONS INPUT POWER Voltage Model mA Model AC Voltage Tolerance AC Frequency Max. Inrush Current after 1 msec (mA version) OUTPUT mA Output mA Max. Loop Resistance Voltage Output Voltage Min. Load Resistance Voltage Min. Sinking Current HUMIDITY RH Element Accuracy Temperature Effect (Outside 20° to 30°C) Response Time (to 90% change at 20°C) Annual Drift Output Scaling Class 2; 12 to 24 Vdc or 24 Vac Class 2; 12 to 24 Vdc ±10% 50/60 Hz 25 mA 4 to 20mA, 2-wire, not polarity sensitive 500 at 24 Vdc input voltage; 250 at 12 Vdc input voltage 0 to 5 V or 0 to 10 V (jumper selectable) 5 k 0.2 mA Digitally profiled thin-film capacitive, non-removable ±2%, 3%, or 5% (10 to 90% RH, 20 to 30 °C) 0.1% RH per °C 110 sec 1% 0 to 100% RH TEMPERATURE OPTION Active Output Accuracy Active Output Temp Scaling Self-Heating Error (Resistive temperature only) OPERATING ENVIRONMENT Operating Temperature Operating Humidity HOUSING Material Mounting Holes WARRANTY Limited Warranty AGENCY APPROVALS ±0.5 °C (±.9 °F) 10 to 35 °C (50 to 95 °F) ±0.5 °C at 20 to 30 °C (68 to 86 °F); ±0.75 °C outside of 20 to 30 °C (68 to 86 °F) 0 to 50 °C (32 to 122 °F) 0 to 100% RH non-condensing (Unit will recover from saturation) ABS plastic with UL V-0 5VB Flame Class US and European junction box 1 year EMC Conformance: Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU. 129 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Humidity Monitoring | HEW Series 0-5V/0-10V MODELS, TEMPERATURE TRANSMITTER Wiring Diagram Digital Control Temp In RH In Power Source AC/DC RTD Temp/RTD RH GND PWR 0-5V/0-10V MODELS, TEMPERATURE TRANSMITTER Wiring Diagram Digital Control Thermistor In Thermistor In RH In Power Source AC/DC RTD Temp/RTD RH GND PWR 4-20 mA MODELS, TEMPERATURE TRANSMITTER Wiring Diagram Digital Control Temp Return T- RH Return T+ RH- Power Source RH+ DC 4-20 mA MODELS, THERMISTOR Wiring Diagram Digital Control Thermistor T- Thermistor T+ RH Return RH- RH+ Power Source DC DIMENSIONAL DRAWING 1.3" (34 mm) 4.9" (123 mm) 3.2" (82 mm) ORDERING INFORMATION Accuracy HEW 2 = 2% 3 = 3% 5 = 5% Output US or EU SS M = 4-20mA V = 0-5 Vdc/0-10 Vdc = Standard Examples: With Temp: HEW 3 M S T C Without Temp: HEW 3 V S X Stop Here *Not available with W and Y high-accuracy thermistors. Temp. Sensor Type Temp Cert T = Temp X = No Temp (Stop here) A = Temp. Transmitter B = 100R Platinum, RTD C = 1k Platinum, RTD D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor G = 10k CPC Thermistor H = 10k T3, Thermistor J = 10k Dale, Thermistor K = 10k with 11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm TAC, Thermistor R = 10k US, Thermistor S = 10k 3A 221 Thermistor T = 100k, Thermistor U = 20k "D", Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Blank = None 1 = 1 pt cal* 2 = 2 pt cal* 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 130 Humidity Monitoring | Deluxe Duct & Outdoor Humidity Sensors HD & HO SERIES 1% & 2% NIST, or Standard 2%, 3%, or 5% HO Sensor element Thin-film capacitive sensor element recovers from 100% saturation Easy servicing Duct sensor element can be serviced without disturbing conduit Accuracy Fully interchangeable element to 1%, 2%, 3%, or 5% accuracy...no calibration Potted circuitry Prevents costly condensate shorts HD HD and HO Series deluxe humidity transmitters provide an ideal solution for measuring relative humidity in a wide range of conditions. All devices are equipped with a thin-film capacitive sensor that is easily replaceable in the field. These sensors are calibrated to NIST standards, with certificates available (see Ordering Information; choose "N" in NIST block). Temperature sensing options are also available. The duct mounted HD is encased in a die cast metal housing for extra strength. The outdoor HO housing is completely weather proof the most rugged sensor available. All deluxe HD and HO models come with a standard five-year warranty. SPECIFICATIONS INPUT POWER Voltage Model* mA Model OUTPUT Voltage Model mA Model HUMIDITY HS Element Accuracy at 25°C from 10-80% RH** (Multi-point calibration, NIST traceable) Temperature Effect, Duct Model Temperature Effect, Outdoor Model Scaling Hysteresis Linearity Reset Rate*** Stability Class 2; 12 to 30 Vdc/24 Vac, 15 mA max. Class 2; Loop powered 12 to 30 Vdc only, 30 mA max. 3-wire, observe polarity 2-wire, not polarity sensitive (clipped and capped) Digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 HD only: ±1% at 20 to 40% RH in mA output mode; (multi-point calibration, NIST traceable) All models: 2%, 3%, or 5% (specify) ±0.1% RH/°C above or below 25 °C (typical) 4 to 20 mA version: (0.0013x%RHx(T°C-25)); 0-5V/0-10V versions: (0.0015x%RHx(T°C-25)) (%RHx0.0008xabs(T°C-25)) 0 to 100% RH 1.5% typical Included in accuracy spec. 24 hours ±1%@20 °C (68 °F) annually, for two years Field replacable Replace element in the field... maintain accuracy and minimize downtime APPLICATIONS · Controlling HVAC systems for improved comfort and energy savings · Museums, schools, printing shops, and other locations requiring humidity control Flexibility Polarity insensitive, two-wire 4 to 20 mA or 3-wire 0-5/0-10 Vdc versions...flexible systems compatibity...save time in the field, stock fewer devices · Facilitating compliance with ASHRAE standards for environmental control and indoor air quality TEMPERATURE Optional Temp. Transmitter Output HO Transmitter Accuracy HD Transmitter Accuracy Digital, 4 to 20 mA (clipped & capped) or 0-5/0-10 V output ±1.3 °C (±2.3 °F) typical; ±0.5 °C (1.0 °F) typical OPERATING ENVIRONMENT Operating Humidity Range 0 to 100% RH non-condensing Operating Temp. Range -40 to 50 °C (-40 to 122 °F) WARRANTY Limited Warranty 5 years AGENCY APPROVALS * One side of transformer secondary is connected to signal common, so an Isolation transformer or dedicated power supply may be required. ** Specified accuracy with 24 Vdc supplied power with rising humidity. RTD/Thermistors are not compensated for internal heating of product. *** Reset Rate is the time required to recover to 50% RH after exposure to 90% RH for 24 hours. All deluxe models come with a standard five-year warranty. The HS sensing element has a 1-year warranty. The element is not a part of the 5-year product warranty. Shielded cabling is required for conformance to EMC standards. Technical information is available from the factory upon request or from the Veris website at www.veris.com. EMC Conformance - CE Option: Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/ EU. EMC note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). 131 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Humidity Monitoring | HD & HO Series HD/HO (0-5V/0-10V TEMPERATURE TRANSMITTER VERSIONS) Wiring Diagram BLK POWER SUPPLY 24 Vdc + RED BLUE 0 to 10 V HUMIDITY ORANGE 0 to 10 V TEMP GREEN 0 to 5 V HUMIDITY YELLOW 0 to 5 V TEMP HO (0-5V/0-10V RESISTANCE VERSIONS) Wiring Diagram POWER SOURCE AC/DC (See Specifications) BLK (Common) RED { optional BLUE 0 to 10 V HUMIDITY GREEN 0 to 5 V HUMIDITY ORANGE THERMISTOR ORANGE THERMISTOR HD/HO (4-20 mA TEMPERATURE TRANSMITTER VERSIONS) Wiring Diagram POWER SOURCE DC Only (See specifications) BLUE HUMIDITY ORANGE TEMP White/Gray 0 to 1 V Test Leads for use with voltmeter DIGITAL CONTROL Humidity 4 to 20 mA Return Temperature 4 to 20 mA Return (optional) BLUE HUMIDITY ORANGE TEMP HO (4-20 mA RESISTANCE VERSIONS) Wiring Diagram + POWER SUPPLY 24 Vdc only BLUE HUMIDITY ORANGE TEMP White/gray 0 to 1 V test leads for use with voltmeter DIGITAL CONTROL Humidity 4 to 20 mA Return Temperature 4 to 20 mA Return (optional) BLUE HUMIDITY ORANGE TEMP ORDERING INFORMATION Enclosure Accuracy NIST H Output US or EU Temp. HD Dimensional Drawing 0.7" (18 mm) 2.9" (74 mm) 4.6" (117 mm) Foam Gasket 2.5" x 2.5" (64 mm x 64 mm) 2.0" (51 mm) HO Dimensional Drawing 2.7" (69 mm) 2.3" (58 mm) 2.8" (72 mm) 8.5" (216 mm) 4.6" (116 mm) 12.2" (310 mm) Humidity Transmitter Combination Sensor Type A = Transmitter Range 1 = -40 to 50 °C (-40 to 122 °F) 2 = 0 to 50 °C (32 to 122 °F) OPTION Temp. Cert Blank = None 1 =1pt cal 2 = 2pt cal Humidity RTD/Thermistor Combination Sensor Type OPTION Temp. Cert 0.5" Dia. (13 mm.) 0.7" (18 mm) D = RH Duct O = Outdoor 1 = 1%* 2 = 2% 3 = 3% 5 = 5% N = NIST 1% & 2% only X = None 2%, 3%, 5% only M = 4 to 20 mA V = 0-5V/0-10 Vdc S = Standard C = CE T = Temp X = No Temp (Stop here) *1% not available on HO. ** Not available with W and Y high-accuracy thermistors. Examples Temp: HD 2 N V C T C 2 No Temp: HO 2 X M S X B = 100R Platinum, RTD C = 1k Platinum, RTD D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor G = 10k CPC, Thermistor H = 10k T3, Thermistor J = 10k Dale, Thermistor K = 10k with 11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm TAC, Thermistor Q = 1uA/°C, Linitemp R = 10k US, Thermistor S = 10k 3A 221, Thermistor T = 100k, Thermistor U = 20k "D", Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Blank = None 1 = 1pt cal** 2 = 2pt cal** ACCESSORIES AA42 Water Guard, Humidity Sensor Protection Shield 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 132 Humidity Monitoring | Specialty Humidity Sensors HN & HP SERIES Pendant and Insertion HN HP Sensor element Thin-film capacitive sensor element recovers from 100% saturation Flexibile Pendant and insertion versions for application flexibility Corrosion resistant Electronics are encapsulated in stainless steel probe to resist corrosion Compatibility Polarity insensitive two-wire 4 to 20 mA or 3-wire 0-5/0-10 Vdc versions...flexible systems compatibity Interchangable Fully interchangeable element to 1%, 2%, 3%, or 5% accuracy...no calibration Calibration free Calibration-free interchangeable NIST traceable HS element HN and HP Series probe type humidity transmitters are easy to install and exceptionally accurate. Their long-term stability and troublefree serviceability make them among the best in the industry. The electronics are embedded inside the probe, protecting them from condensation-related failures. The thin-film capacitive HS sensor elements are factory calibrated using NIST traceable calibration equipment, eliminating the need for field calibration. Field replacement of the sensor element is a snap with the patented removable sensor, lowering costs and reducing downtime. APPLICATIONS · HVAC control for improved comfort and energy savings · Museums, schools, printing shops, and other locations requiring humidity control · Facilitating compliance with ASHRAE standards for environmental control and indoor air quality SPECIFICATIONS INPUT POWER Voltage Model mA Model OUTPUT Voltage Model mA Model HUMIDITY HS Element Accuracy @ 25°C** Reset Rate*** Stability Hysteresis Linearity Temperature Coefficient Scaling TEMPERATURE OPTION Optional Temperature Transmitter Output Class 2; 12 to 30 Vdc/24 Vac, 15 mA max. Class 2; Loop powered 12 to 30 Vdc only, 30 mA max. 3-wire, observe polarity 2-wire, not polarity sensitive (clipped & capped) Digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 ±1%, 2%, 3%, or 5% (specify)@10 to 80% RH; Multi-point calibration, NIST traceable 24 hours ±1%@20 °C (68 °F) annually, for two years 1.5% typical Included in accuracy spec. ±0.1% RH/°C above or below 25 °C (typical) 0 to 100% RH Digital, 4 to 20 mA (clipped & capped) or 0-5/ 0-10 V output; accuracy ±0.5 °C (±1 °F) typical OPERATING ENVIRONMENT Operating Humidity Range Operating Temp Range WARRANTY Limited Warranty AGENCY APPROVALS 0 to 100% RH non-condensing -40 to 50 °C (-40 to 122 °F) 5 years Available * One side of transformer secondary is connected to signal common, so an Isolation transformer or dedicated power supply may be required. ** Specified accuracy with 24 Vdc supplied power with rising humidity. RTD/Thermistors are not compensated for internal heating of product. *** Reset Rate is the time required to recover to 50% RH after exposure to 90% RH for 24 hours. The HS sensing element has a 1-year warranty. The element is not a part of the 5-year product warranty. Shielded cabling is required for conformance to EMC standards. Technical information is available from factory upon request or is available on our website: www.veris.com. EMC Conformance - CE Option: Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU. EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). 133 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Humidity Monitoring | HN & HP Series HN/HP (0-5V/0-10V VERSIONS) Wiring Diagram POWER SUPPLY 24 Vdc BLK + RED BLUE 0 to 10 V HUMIDITY ORANGE 0 to 10 V TEMP GREEN 0 to 5 V HUMIDITY YELLOW 0 to 5 V TEMP HN/HP WITH RTD/THERMISTOR (0-5V/0-10V VERSIONS) Wiring Diagram BLK POWER SUPPLY 12 to 24 Vdc/24 Vac + RED BLUE 0 to 10 V HUMIDITY GREEN 0 to 5 V HUMIDITY ORANGE THERMISTOR ORANGE THERMISTOR HN/HP WITH RTD/THERMISTOR (4-20 mA VERSIONS) Wiring Diagram POWER SUPPLY 12 to 24 Vdc BLUE + HUMIDITY White/Gray 0 to 1 V Test Leads for use with voltmeter DIGITAL CONTROL Humidity 4 to 20 mA Return Temperature 4 to 20 mA Return (optional) BLUE HUMIDITY ORANGE Thermistor ORDERING INFORMATION ORANGE Thermistor HN SERIES Dimensional Drawing Foam Gasket 2.5" x 2.5" (64 mm x 64 mm) 3.5" (89 mm) 36" (914 mm) HP SERIES Dimensional Drawing 8.0" (203 mm) 10" (254 mm) 36" 914 mm 10.0" 254 mm HN/HP (4-20 mA VERSIONS) Dimensional Drawing 0.5" Dia. (13 mm) 0.5" Dia. 13 mm + POWER SUPPLY 24 Vdc only DIGITAL CONTROL Humidity 4 to 20 mA Return Temperature 4 to 20 mA Return (optional) BLUE HUMIDITY ORANGE TEMP BLUE HUMIDITY ORANGE TEMP White/gray 0 to 1 V test leads for use with voltmeter Humidity Transmitter Combination Sensor Type A Range OPTION Temp Cert = Transmitter 1 = -40 to 122 °F (-40 to 50 °C) 2 = 32 to 122 °F (0 to 50 °C) Blank = None 1 = 1pt Cal 2 = 2pt Cal Enclosure H Accuracy NIST Output US or EU Temp. Humidity RTD/Thermistor Combination Sensor Type OPTION Temp Cert N = RH Insertion P = RH Pendant 1 = 1% 2 = 2% 3 = 3% 5 = 5% N = NIST 1%, & 2% only X = None 2%, 3%, 5% only M = 4 to 20 mA S = Standard V = 0-5V/0-10 Vdc C = CE T = Temp X = No Temp (Stop here) Example: (No Temp) HP 2 X V S X Stop Here Example: (With Temp) HN 2 X V S T C 2 * Not available with W and Y high-accuracy thermistors. B = 100R Platinum, RTD C = 1k Platinum, RTD D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor G = 10k CPC,Thermistor H = 10k T3, Thermistor J = 10k Dale, Thermistor K = 10k with 11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm TAC, Thermistor Q = 1uA/°C, Linitemp R = 10k US, Thermistor S = 10k 3A 221, Thermistor T = 100k, Thermistor U = 20k "D", Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Blank = None 1 = 1pt cal* 2 = 2pt cal* ACCESSORIES AA42 Water Guard, Humidity Sensor Protection Shield 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 134 Humidity Monitoring | Economy Duct Humidity Sensors HED SERIES 2%, 3%, and 5% Accuracies HED RH & temperature Easy hook-up Monitor humidity and Large cage clamp terminal temperature with a single device... blocks...easy hook-up with reduces installation costs no wire nuts Sensor options Semiconductor temperature transmitter, or popular thermistor/RTD sensors available No lost screws Tool-less gasketed entry lid Embedded circuitry Circuitry is embedded in the probe for durability and protection HED Economy Series duct mount humidity transmitters offer high performance in an easy-to-install housing at an affordable price. The thin-film capacitive sensor element provides high accuracy and performance, great long-term stability, and full recovery from saturation. Temperature sensing options are also available. The duct-mounted HED includes a rugged all plastic housing with a tool-less gasketed entry lid, large cage clamp terminal blocks, and sturdy ABS material. All Economy models come with a standard one-year warranty. APPLICATIONS · HVAC economizer control · Managing energy systems · Facilitating ASHRAE standards for environmental control SPECIFICATIONS INPUT POWER Voltage Version mA Version AC Voltage Tolerance AC Frequency Max. Inrush Current after 1 msec (mA version) OUTPUT mA Output mA Max. Loop Resistance Voltage Output Voltage Min. Load Resistance Voltage Min. Sinking Current HUMIDITY RH Element Accuracy Temp Effect (Outside 20° to 30°C) Response Time (to 90% change at 20°C) Class 2; 12 to 24 Vdc or 24 Vac Class 2; 12 to 24 Vdc ±10% 50/60 Hz 25 mA 4 to 20 mA, 2-wire, not polarity sensitive 500 at 24 Vdc input voltage; 250 at 12 Vdc input voltage 0 to 5 V or 0 to 10 V (jumper selectable), observe polarity 5 k 0.2 mA Digitally profiled thin-film capacitive, non-removable ±2%, 3%, or 5% (10 to 90% RH, 20 to 30 °C) 0.1% RH per °C 110 sec Annual Drift 1% Output Scaling 0 to 100% RH TEMPERATURE OPTION Active Output Accuracy ±0.5 °C (±.9 °F) Active Output Temperature Scaling Type 1: -40 to 50 °C (-40 to 122 °F); Type 2: 0 to 50 °C (32 to 122 °F) Self-Heating Error (Resistive ±0.5 °C at 20 to 30 °C (68 to 86 °F); Temperature Only) ±0.75 °C outside of 20 to 30 °C (68 to 86 °F) OPERATING ENVIRONMENT Operating Temperature -40 to 50 °C (-40 to 122 °F) Operating Humidity 0 to 100% RH non-condensing (unit will recover from saturation) HOUSING Material ABS plastic with UL V-0 5 VA Flame Class WARRANTY Limited Warranty 1 year AGENCY APPROVALS EMC Conformance: Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU. Meets UL requirements for plenum rating. 135 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 0-5V/0-10V MODELS, TEMPERATURE TRANSMITTER Wiring Diagram Digital Control Temp In RH In Power Source AC/DC RTD Temp/RTD RH GND PWR 0-5V/0-10V MODELS, THERMISTOR Wiring Diagram Digital Control Thermistor In Thermistor In RH In Power Source AC/DC RTD Temp/RTD RH GND PWR 4-20 mA MODELS, TEMPERATURE TRANSMITTER Wiring Diagram Digital Control Temp Return T- RH Return T+ RH- Power Source RH+ DC ORDERING INFORMATION Accuracy HED 2 = 2% 3 = 3% 5 = 5% Output US or EU S M = 4 to 20 mA V = 0-5/0-10 Vdc = Standard Temp. T = Temp X = No Temp (Stop here) Examples: HED 3M S T C HED 3V S X * Not available with W and Y high-accuracy thermistors. Humidity Monitoring | HED Series DIMENSIONAL DRAWING 2.1" (53 mm) 4.9" (123 mm) 6.1" (155 mm) 1.0" (25 mm) 3.2" (82 mm) 4-20 mA MODELS, THERMISTOR Wiring Diagram Digital Control Thermistor T- Thermistor T+ RH Return RH- RH+ Power Source DC Sensor Type A Temp Range Temp Cert = Temp. transmitter 1 = -40 to 50 °C (-40 to 122 °F) 2 = 0 to 50 °C (32 to 122 °F) Blank = None 1 = 1 pt cal 2 = 2 pt cal Sensor Type Temp Cert B = 100R Platinum, RTD C = 1k Platinum, RTD D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor G = 10k CPC Thermistor H = 10k T3, Thermistor J = 10k Dale, Thermistor K = 10k with 11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm TAC, Thermistor R = 10k US, Thermistor S = 10k 3A 221 Thermistor T = 100k, Thermistor U = 20k "D", Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Blank = None 1 = 1 pt cal* 2 = 2 pt cal* 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 136 Humidity Monitoring | Replaceable Humidity Elements HS SERIES Easy Field Replacement for Veris Deluxe Humidity Sensors HS Generation 1 U.S. Patent No. 5,844,138 HS Generation 2 ORDERING INFORMATION Generation 1 HS elements work with HD, HN, HP, HO and legacy HWL/HWX and CWL sensors models. Accuracy HS 1 = 1%* 2 = 2% 3 = 3% 5 = 5% NIST X N = NIST (1% & 2% models only) X = None (2%, 3%, & 5% models only) Example: HS 5 X X *1% HS sensors used in outdoor applications are limited by the device to 2% accuracy. Note: 1-year limited warranty. The HS replaceable humidity element is designed to lower costs and reduce downtime. It features thin-film capacitive technology for superior accuracy and exceptional resistance to contaminants. It is compatible with all Veris deluxe sensors, making replacement quick and easy. No need to install a new humidity sensing device, just insert a new element into the unit and resume operation. These humidity elements are calibrated in a high accuracy, NIST traceable, humidity generator. Each sensor is digitally calibrated at four different relative humidity levels over an eight-hour period. Calibration data is programmed into the replaceable sensing element. This computer-controlled digital calibration eliminates errors associated with manual "trimming." A certificate of calibration is provided with NIST versions of the HS. Veris' calibration system produces known humidity values using the fundamental principle of the "two pressure" generator developed by NIST (H-4622). The two-pressure method involves saturating air with water vapor at a given pressure and temperature. Saturated gas then flows through an expansion valve where it is isothermally reduced to chamber pressure. Gas temperature is held constant during pressure reduction, so relative humidity at chamber pressure is calculated as the ratio of two absolute pressures. Temperature uniformity in the chamber is maintained by circulating a temperature controlled fluid through a shell surrounding the test space. Highly accurate pressure measurements are made using NIST traceable piezoresistive transducers. The resulting system accuracy is better than 0.5% RH over all ranges and temperatures. This system is capable of continuously supplying accurate humidity values for instrument calibration, evaluation, and verification. Generation 2 HS elements work with HW2 and CW2 sensor models. Accuracy HS 1 = 1% 2 = 2% NIST N = NIST X = None (2% models only) Example: HS 2 X Note: 1-year limited warranty. 137 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Humidity Monitoring | HS Series HS Digital Humidity Sensor Certificate of Performance Serial Number: Date: Accepted by: This sensor has been computer pro led and calibrated at multiple relative humidity levels using standards traceable to the National Institute of Standards and Technology through test #H-4622. The humidity standard produces atmosphere of known humidity based on the "two-pressure" principal which is to saturate an air stream with water vapor at a given pressure and temperature. The saturated air stream is then reduced to test pressure. The humidity at test pressure is then the ratio of the two absolute pressures, corrected for vapor pressure and enhancement factor ratios. Reference Reading Di erence 12.0% 12.39% +0.39% +3% 20.0% 20.43% +0.42% 30.0% 29.93% -0.07% +2% 40.0% 40.21% +0.21% +1% 50.0% 49.98% -0.02% 60.0% 60.05% +0.05% 0% 70.0% 69.87% -0.13% -1% 80.0% 79.67% -0.33% -2% 100% -3% 10% 30% 50% 70% 90% 90% 80% 70% 60% 50% 40% 30% 20% 10% Sample interval: 3 minutes 0% HOURS 2 4 6 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 138 LEAK DETECTION To protect expensive electronics from costly water damage, Veris offers complete leak detection systems. Monitor either a single location or a large area with our selection of highly reliable sensing devices and controller systems. MODEL LD310, LD1000 & LDRA6 LD1500 & LD2100 LD5200 SD, SD-R01 & MX1B SC & NSC LC-KIT Zone Leak Detection Panels Distance Read Panels Distance Read Panel, Touch Screen Spot Leak Detectors Cables Leak Detection Kit DESCRIPTION PAGE 141 143 145 147 149 151 LEAK DETECTION SENSOR SELECTION GUIDE SENSORS AND CONTROL PANELS FEATURES Basic Model Leak Detection with Relay Output SPOT DETECTION SD/MX1B page 147 SD-R01 page 147 SINGLE ZONE LD310/LD1000 page 141 Modbus Output MULTI-ZONE LDRA6 page 141 LDRA6 page 141 CABLES FEATURES Basic Model CABLE KITS LC-KIT page 151 CONDUCTIVE FLUIDS SC page 149 NON-SENSING LEADER CABLE NSC page 149 DISTANCE READ LD1500/LD2100 page 143 LD5200 page 145 LD1500/LD2100 page 143 LD5200 page 145 139 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com PROTECT CRITICAL EQUIPMENT WITH EARLY LEAK DETECTION LD and SC SERIES Liquid and Chemical Sensors and Controllers APPLICATIONS » Suitable for areas where water damage is a concern » Detect exact location of leaks in sprinkler systems » Detect chiller leaks in critical areas before becoming a major problem » Single location or large area monitoring FEATURES EASY TO SPECIFY AND INSTALL Zone controller kits pre-configured in convenient lengths Easily expand an existing sytem using mating end connectors VERSATILE APPLICATION Detect the presence of specific fluids only Plenum rated and UL listed Strong, durable, and abrasion resistant PC CONFIGURATION Summary alarm relay output for faster response QUIET AND EASY TROUBLESHOOTING LED indicator for alarm status Fault LED indicates connectivity loss (some models) DETECTION ACCURACY Added control with sensitivity setting for each zone Adjustable leak and contamination alarm thresholds Reduced false alarms due to high humidity 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 140 Leak Detection | Zone Leak Detection Panels LD310, LD1000, & LDRA6 Zone Leak Detection Controllers Application flexibility Output versatility Monitor up to 1,000 ft. (300 m) of water leak detection cable per zone with the LD1000 and LDRA6 or 300 ft. per zone with the LD310 LED indicators Alarm and trend logs of the last 100 alarms and 117 days of cable current levels, plus RS-232 and Modbus RS-485 ports (LDRA6 only) Fast response LDRA6 LD1000 LD310 LD310, LD1000, and LDRA6 control panels continuously monitor up to 1,000 ft. (300 ft. for the LD310) of SC detection cable per zone. If the cable detects fluid at any point along its length, the detection panel illuminates the corresponding zone LED, clearly indicating which zone is affected. An alarm (visual for LD310, audible for all others) signals the presence of a leak. Additionally, if the cable loses continuity, the panel will activate a cable fault LED. The detection sensitivity can be set independently for each zone. A summary alarm relay output is standard. The LDRA6 can interface with a computer via an RS-232 port, through which 117 days of cable current level readings and the last 100 alarms can be accessed for analysis. The LDRA6 also offers a Modbus slave port allowing other devices to communicate with it. SPECIFICATIONS Two LED indicators per zone, for easy troubleshooting...leak and cable fault (LD1000 and LDRA6) Sensitivity settings Sensitivity settings for each zone reduce false alarms...maximum detection accuracy APPLICATIONS · Monitoring data centers, computer room under-floor areas, mechanical rooms, and electrical control centers · Protecting records storage Summary alarm relay output... fast response · Monitoring plumbing · Monitoring chilled beams · Monitoring chemical/fuel storage Input Power: LD310 LD1000 LDRA6 5 Vdc ±10% 24 Vac/dc (±10%)@300 mA max. (AC: 50/60 Hz) 24 Vac/dc (±10%)@600 mA max. (AC: 50/60 Hz) Relay Output: LD310 LD1000 LDRA 2 Form C relays (leak and fault); 1 A@24 Vdc, 0.5 A resistive@120 Vac 2 Form C relays (leak and fault); 1 A@24 Vdc, 0.5 A resistive@120 Vac 1 Form C summary alarm relay, 1 Form C relay for each zone/alarm; 1 A@24 Vdc, 0.5 A Resistive@120 Vac INPUTS Water Leak Detection Cable Requires 15 ft. (4.5 m) leader cable kit (LC-Kit) per zone. Maximum Cable Length: LD310 LD1000, LDRA6 300 ft. (91 m) 1000 ft. (305 m) Detection Response Time: LD310 LD1000 LDRA6 < 20 sec (10 sec typical) Configurable for 10 sec or 2 min, ± 10% 20 to 3600 sec, software adjustable in 10 sec increments, ± 2% COMMUNICATION PORTS (LDRA6 ONLY) RS-232 & RS-485 1200, 2400, 9600, or 19200 selectable; no parity; 8 data bits, 1 stop bit Terminal Emulation (RS-232) VT100 Compatible (configuration) Modbus (RS-485) (LDRA6 only) Slave; RTU Mode; Supports function codes 03, 04, 06 and 16 NOTIFICATION Alarm Notification: Audible Alarm LD1000 LDRA6 85 dBA@2 ft. (0.6 m) 85dBA@2 ft. (0.6 m) re-sound disabled, 8, 16, or 24 hrs. Push Buttons: LD1000, LDRA6 1 for reset, quiet, and test OPERATING ENVIRONMENT Temperature 0 to 50 °C (32 to 122 °F) Humidity 5% to 95% RH non-condensing Altitude 15,000 ft. (4,572 m) max Storage Environment -20 to 70 °C (-4 to 158 °F) Weight: LD310 LD1000 LDRA6 3 oz. (85 g) 27 oz. (766 g) 4 lbs. (2 kg) AGENCY APPROVALS Agency Approvals: LD310 LD1000 LDRA6 CE, RoHS compliant CE, ETL listed; conforms to UL 61010-1, RoHS compliant CE ETL Listed; conforms to UL 61010-1, EN 61010-1, CAN/CSA C22.2 No. 1010.1, RoHS compliant WARRANTY Limited Warranty INTERTEK CM 2 years C US LISTED LISTED 3037024 141 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Leak Detection | LD310, LD1000, & LDRA6 LD310 Wiring Diagram JP1 - Leak Sensitivity Top 2 Pins - Most sensitive No Jumper - Medium sensitivity Bottom 2 Pins - Least sensitive Top 2 Pins - Supervised Bottom 2 Pins - Non-supervised L Brackets Audible Alarm LED Silence/Test/ Reset Button JP3 - Audible Alarm Top 2 Pins - Disabled Bottom 2 Pins - Enabled Circuit Board Clip Leader Cable / Leak Detection Input Plastic Peg 5VDC Power Input Cable Fault Leak Relay Output Relay Output Plastic Peg Be sure the leader cable is wired into the correct pinouts. LD310 OR LD1000 BASIC INSTALLATION WITH SC SENSING CABLE AND SD-Z SPOT DETECTOR Wiring Diagram LD310 Dimensional Drawing 2.5" (63.5 mm) LD310 4.4" (112 mm) LD1000 Dimensional Drawing Quiet/Reset/Test Power Fault Leak 5.5" (140 mm) LDRA6 Dimensional Drawing Alarm/Zone 1 Alarm/Zone 2 Alarm/Zone 3 Power Test/Reset/Silence Alarm/Zone 4 Alarm/Zone 5 Alarm/Zone 6 4.2" (105 mm) 8.0" (203 mm) LD310 LD1000 or Leader cable kit (LC-Kit) SC NSC End Terminator (EOL) Spot detector (SD-Z) BLINK CODE KEY MODEL LD310 LD310 LD310 LD1000 LD1000 LD1000 LDRA6 LDRA6 LDRA6 LDRA6 LED INDICATION Solid green (on or off) Flashing green (0.5 sec on/2.5 sec off) Flashing green (0.5 sec on/0.5 sec off) Solid green (on or off) 1 amber 1 red Solid green (on or off) 1 green 1 red 1 yellow DEVICE STATUS Normal operation Cable fault Leak detected Normal operation Cable fault Leak detected Normal operation Power on Leak detected Cable fault 10.5" (267 mm) ORDERING INFORMATION MODEL MANUF. PART # DESCRIPTION U006-0080* LD310* Leak Panel, 1 zone, LED, 2 relay outputs U006-0001** LD1000** Leak Panel/Remote Annunciator, 1 zone, supervised, relay output U006-0036** LDRA6** Leak Panel, up to 6 zones, supervised, relay output, Modbus RTU U006-0035 LC-KIT*** Leader cable kit for SC cables (connects from leak panel to SC or NSC cable) U006-0037 WA-DC-05 Power Supply for LD300 U006-0084 PS-WA-DC-24 Power Supply for LD1000 and LDRA6 * Power supply not included; requires U006-0037 power supply. ** Power supply not included; requires U006-0084 power supply. *** Included with LD310 and LD1000. ACCESSORIES P. 153 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 142 Leak Detection | Distance Read Panels LD1500 & LD2100 Helps Eliminate High Humidity False Alarms LD2100 LD1500 High detection accuracy Adjustable leak and contamination alarm thresholds reduce false alarms due to high humidity... high detection accuracy PC configuration Summary alarm relay output... fast response Together with the SC sensing cable, the LD1500 and LD2100 panels detect and report the presence and location of the cable-specific fluid. When the fluid comes in contact with the patented cable, the monitoring panel quickly pinpoints the location of the leak, triggering an alarm and displaying the location. SPECIFICATIONS Input Power INPUTS Water Leak Detection Cable Maximum Length Detection Accuracy Detection Repeatability Detection Response Time OUTPUTS Relay (LD2100 only) COMMUNICATIONS PORTS RS-232 RS-485 PROTOCOLS Terminal Emulation: RS-232 Modbus RS-485 EXPANDED PROTOCOLS TCP/IP, HTML, TFTP SNMP SMTP email, LD2100 only Modbus TCP/IP BACnet/IP ALARM NOTIFICATION Audible Alarm: LD2100 Visual Alarm: LD1500 LD2100 24 Vac@600 mA max., 50/60 Hz Requires 15 ft. (4.5 m) leader cable kit (LC-KIT or LC-KIT-M) LD1500: 1500 ft. (457 m); LD2100: 5000 ft. (1524 m) ±2 ft (0.6 m) + 0.5% of the cable length ±2 ft (0.6 m) + 0.25% of the cable length 5 to 995 sec ± 2 sec, configure in 5 steps 1 A@24 Vdc, 0.5 A resistive@120 Vac 9600 baud, No parity, 8 data bits, 1 stop bit 1200, 2400, 9600, or 19200 baud (selectable); No parity, 8 data bits, 1 stop bit VT100 compatible Slave; RTU Mode; Supports function codes 03, 04, 06, and 16; Johnson N2 (LD2100 only) IPv4.0 V1: V2C MIB-2 compliant; NMS Manageable with Get, Set, Traps Supports client authentication (plain and login); compatible with ESMTP servers Modbus slave; TCP/IP transmission protocol ASHRAE Std 135-2004 Annex J 70 dBA@2 ft. (0.6 m); re-sound configurable (disabled, 0 to 24 hours, integer values only) Red, 4-digit; 7 segment LED display; bi-color status LED Bi-color status LED Email LD1500/LD2100 4 email recipients; email sent on Alarm and Return to Normal SNMP Traps LD1500, LD2100 4 community strings LOGGING CAPABILITIES Event Log LD1500 LD2100 Last 10 events Last 500 events Trend Log LD2100 Cable current level every day, for the last 288 days LOGIN SECURITY Display Access 1 Administrator (password for configuration, no password required to view panel status) FRONT PANEL INTERFACE Display LD2100 Green alphanumeric dot matrix Push Buttons LD2100 Test/Reset LED Indicator LD1500 LD2100 1 tri-color Power/Status (green = power on; red = alarm; yellow = cable fault 1 bi-color Power/Status (green=power on, red=alarm) OPERATING ENVIRONMENT Temperature 0 to 50 °C (32 to 122 °F) Humidity 5 to 95% RH non-condensing Altitude 15000 ft. (4572 m) max. Mounting Vertical wall mount (DIN rail mounting option available on LD2100 only) WARRANTY Limited Warranty 2 years AGENCY APPROVALS Agency Approvals CE; ETL listed: conforms to UL 61010-1, EN 61010-1; CSA C22.2; RoHS compliant INTERTEK CM C US LISTED LISTED 3037024 143 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com LD1500 Dimensional Drawing 7.0" (176 mm) Leak Detection | LD1500 & LD2100 LD2100 Dimensional Drawing 8.0" (203 mm) 3.7" (94 mm) 4.25" (108 mm) LD1500/LD2100 BASIC SC INSTALLATION Wiring Diagram Power supply (U006-0084) Cable WB G R Leader Cable (LC-KIT) (included with LD1500 and LD2100) Sensing Cable (SC) End Terminator (EOL) (included with LC-KIT) ORDERING INFORMATION MODEL MANUF. PART # DESCRIPTION U006-0038* LD1500* Leak Panel, 1500' Distance Read, Modbus, BACnet, SNMP, SMTP, and relay outputs U006-0047* LD2100* Leak Panel, 5000' Distance Read, Modbus, BACnet, SNMP, SMTP, and relay outputs U006-0035** LC-KIT** Leader cable kit for SC cables (connects from leak panel to SC or NSC cable) U006-0084 PS-WA-DC-24 24 Vdc isolated power supply for LD1500 and LD2100 * Power supply not included. Isolated power supply must be used. Use LD-ENC (U006-0045) wall mount enclosure with built-in power supply or U006-0084 power supply. ** Included with LD1500 and LD2100. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 153 144 Leak Detection | Distance Read Panel, Touch Screen LD5200 Minimizes High Humidity False Alarms Touch screen Touch screen interface allows access to basic functions... stand-alone configuration and monitoring Troubleshooting Detailed alarm history with time and date stamps...assists in troubleshooting LD5200 distance read panel has an innovative touch screen interface that accesses all basic functions. The LD5200 can operate as a standalone device, with the user configuring, monitoring, locating, and acknowledging leaks at the panel. It can also be connected to the building network and accessed via a web interface, which expands the capabilities of the unit, adding a convenient interactive facility mapping tool. When a leak is detected, the mapping tool displays the location in the building where the alarm occurred. Multiple communication protocols make the LD5200 readily compatible with existing building systems. Use with our SC sensing cable for a complete solution to leak detection. SPECIFICATIONS Input Power 100 to 240 Vac@500 mA max., 50/60 Hz INPUTS Water Leak Detection Cable LC-KIT or LC-KIT-M Requires 15 ft. (4.5 m) leader cable kit Maximum Length 10000 ft. (3048 m) Minimum Length 35 ft. (1037 m) Detection Accuracy ± 2 ft (0.6 m) + 0.5% of the cable length Detection Repeatability ± 2 ft (0.6 m) + 0.25% of the cable length Detection Response Time 5 to 990 sec ± 2 sec, software adjustable in 5-sec increments OUTPUTS Analog 4 to 20 mA Loop Powered, 18 to 36 Vdc, RL = 500 max. Relay 2 Form C Leak Relays, 2 Form C Cable Break Relays; 1 A @ 24 Vdc, 0.5 A resistive@120 Vac;configurable for supervised or non-supervised, latched or non-latched Maintenance Relay 1 A@24 Vdc, 0.5 A resistive @120 Vac; configurable for supervised or non-supervised, latched or non-latched COMMUNICATIONS PORTS EIA-232 9600 baud, No parity, 8 data bits, 1 stop bit EIA-485 (Port 1, Port 2, Port 3) 9600, 19200, or 38400 baud (selectable); No parity, 8 data bits, 1 stop bit RJ-45 10/100 Bast T Ethernet port (TCP/IP) PROTOCOLS Terminal Emulation VT100 compatible EIA-232 Modbus RTU EIA-485 Master and slave; RTU Mode; BACnet MS/TP; N2, slave Pinpoint leaks Web interface offers expanded capabilities through the building mapping tool...pinpoint leaks quickly and accurately One device Acts as a master device for up to 127 leak detection units with up to 10,000 feet of SC cable ... monitor large areas with only one device Easy integration Multiple communication protocols available...easy integration into building systems RJ-45 Ethernet, TCP/IP; Modbus/TCP/UDP, Master and slave; SNMP V1, V2, V3, NTP, SMTP, DNS, BACnet/IP ALARM NOTIFICATION Audible Alarm 85 dBA@2 ft. (0.6 m); re-sound 0 to 999 min. Visible Alarm Indicated on LCD touch screen & through web interface LOGGING CAPABILITIES Event Log Last 1024 events, downloadable to .txt files Trend Log Cable current level every day for the last 365 days, downloadable to .txt files LOGIN SECURITY LCD Touch Screen No password required to view controller status & data. Administrator password limits access to configuration options. Web Interface Username and password can be configured FRONT PANEL INTERFACE Display 480 x 272 pixel color backlit LCD touch screen; 95.04 mm x 53-85 mm OPERATING ENVIRONMENT Temperature 0 to 50 °C (32 to 122 °F) Humidity 5 to 95% RH non-condensing Altitude 15000 ft. (4572 m) max. Mounting NEMA 1 wall mount enclosure WARRANTY Limited Warranty 2 years AGENCY APPROVALS Agency Approvals CE; ETL listed: conforms to UL 61010-1, EN 61010-1; CAN/CSA C22.2 No. 61010-1; RoHS compliant INTERTEK CM C US LISTED LISTED 3037024 145 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com LD5200 BASIC SC INSTALLATION Wiring Diagrams Leak Detection | LD5200 DIMENSIONAL DRAWING Cable WB G R Leader Cable (LC-KIT) (included with LD5200) Sensing Cable (SC) End Terminator (EOL) (included with LC-KIT) WEB INTERFACE 12.5" (320 mm) 10.0" (254 mm) A robust web interface supports remote access, any time, any place. ORDERING INFORMATION MODEL MANUF. PART # U006-0079 LD5200 U006-0035* LC-KIT *Included with LD5200. DESCRIPTION Leak Panel, Distance Read, supervised, multiple outputs: relay, 4 to 20 mA, Modbus RTU, leader cable and EOL terminator Leader cable kit for SC cables (connects from leak panel to SC or NSC cable) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 153 146 Leak Detection | Spot Leak Detectors SD, SD-R01 & MX1B Spot Leak Detectors MX1B SD Simple installation Simple installation screw, or ramset to floor (SD & SD-R01) Polymer coated SD & SD-R01 models have polymer-coated sensing probes... no exposed metal that will rust Simple operation Durability Simple operation...no maintenance All models are fully potted for water resistance...maximum durability Solid-state design No moving parts to fail SD, SD-R01 and MX1B Spot Detectors detect conductive fluids at a single point for the most economical way to detect fluids in small, confined areas. These devices are commonly used in small rooms and in air-conditioning drip pans. Use only with SC conductive fluid leak detection cables. Veris offers three spot detector models which can integrate with various building management systems. MODEL SD Spot Detector SD-R01 Spot Detector with Relay Output MX1B Spot Detector DESCRIPTION · Operates on either 12 to 36 Vac or 18 to 36 Vdc power · Includes a 14 ft. (4.2 m) leader cable · Works with any system that accepts dry contacts · Operates on 24 Vac/dc ±10% · Automatically resets when conductive fluid is no longer present (AC power only; if DC power is used, device must be reset by disconnecting power momentarily) · Includes a 14 ft (4.2 m) leader cable · Battery operated SPECIFICATIONS SD & SD-R01 Input Power: SD-R01 Only 24 Vac/dc ±10%; 0.1 A max. (AC: 50/60 Hz) Storage Environment -20 to 70 °C (-4 to158 °F) OUTPUTS Solid-state: SD Only 12 to 36 Vac@0.01 A min., 0.1 A max., 50/60 Hz; 18 to 36 Vdc@0.01 A min., 0.1 A max. Relay: SD-R01 Only Dry Contact, Form C; 1 A@24 Vdc, 0.5 A @120 Vac resistive LEADER CABLE (NSC) Length: SD SD-R01 14 ft. (4.2 m) 14 ft. (4.2 m) OPERATING ENVIRONMENT Temperature 0 to 50 °C (32 to 122 °F) Humidity 5% to 95% RH non-condensing Altitude 10,000 ft. (3,048 m) max. WARRANTY Limited Warranty 2 years SPECIFICATIONS MX1B Input Power Typical 10-year life lithium battery Output N.C. solid-state, (opens on alarm) Output Rating 30 Vac/dc@0.1 A max., not polarity sensitive Sensing Electrodes Gold plated OPERATING ENVIRONMENT Temperature -20 to 80 °C (-4 to 176 °F) Humidity 0 to 100% RH Water Resistance Not for continuous submersion WARRANTY Limited Warranty 5 years AGENCY APPROVALS INTERTEK CM C US LISTED LISTED 3037024 147 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Leak Detection | SD, SD-R01 & MX1B SD Wiring Diagram Reset Push Button (Normally Closed) 24 Vdc (not polarity sensitive) White/Red (+) Black (-) SD SERIES Dimensional Drawing SD-R01 Wiring Diagram Reset Push Button (Normally Closed, Vdc applications only) 24 Vac/dc Red (+) Black (-) White (N.O.) Green (Comm) Blue (N.C.) Brown (Not Used) Once triggered, device remains on until power is removed (if using Vdc power). Once triggered, device remains on until power is removed (if using Vdc power). 2.9" (73 mm) 2.1" (52 mm) 0.3" (8 mm) MX1B Wiring Diagram MX1B Dimensional Drawing DIGITAL CONTROL Digital Input Green White 0.75" (19 mm) 0.6" (14 mm) 1.75" (44 mm) = 0.2" (5 mm) 1.0" (25 mm) 1.2" (30 mm) 0.3" (7 mm) 0.3" (7 mm) ORDERING INFORMATION MODEL U006-0006 U006-0007 MX1B MANUF. PART # SD SD-R01 MX1B DESCRIPTION Spot Detector, 14' leader cable Spot Detector, 14' leader cable, relay out Spot Detector, battery CE ETL · · · · 0.5" (13 mm) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 153 148 Leak Detection | Cables SC & NSC Highly Flexible, Resists Bends and Kinks, Abrasion Resistant Strong Strong, durable, and abrasion resistant Plenum rated Plenum rated and UL Listed NSC SC Sensing and non-sensing cables are designed for use with Zone and Distance Read panels. The sensing cables detect the presence of detectable liquid, and send a signal to the panel. The panel generates an alarm and pinpoints the location of the leak or spill along the cable's length. Sensing cables are designed for high accuracy and maximum reliability. SC water detection cable senses the presence of water or other conductive fluid. NSC non-sensing cable is used to extend the control panel's leader cable to an area where SC detection cable is needed. It also bridges lengths of SC detection cable in areas where sensing is not required. Invisible to the control panel, the non-sensing cable does not affect the accuracy of readings or limit the amount of detection cable that can be connected to a control panel. NSC cables are only compatible with systems using SC water detection cables. All cables are highly flexible, durable, and kink-resistant. They lie flat after installation, and are abrasion resistant. The cables are plenum rated and UL Listed, making them ideal for use under raised floors and areas where plenum rated cable is required. Choose a pre-specified cable length or a custom length for your convenience and installation flexibility. Easy installation Expansion with mating end connectors...easy installation Installation flexibility Available in pre-measured and custom lengths with pre-installed end connectors Accurate Highly accurate alarm notification...fewer false alarms SPECIFICATIONS Plenum Rating: SC NSC CL2P/CMP C(UL) CL3P/CMP C(UL) California State Fire Marshall approved Shear Strength: >180 lbs (>81.65 kg) Cut Through Resistance >40 lbs (>18.2 kg) with 0.005" (0.13 mm) blade Abrasion Resistance 60 cycles per UL 719 Connector 4-pin, 1" (25.4 mm) dia., circular, locking, 4-pin OPERATING ENVIRONMENT Temperature 0 to 75 °C (32 to 167 °F) Humidity 5 to 95% RH non-condensing Altitude 15,000 ft. (4,572 m) max. STANDARD LENGTHS SC-10/NSC-10 10 ft. (3.1 m) SC-17 17 ft. (5 .1 m) SC-25/NSC-25 25 ft. (7.7 m) SC-50/NSC-50 SC-100/NSC-100 Storage Environment Weight Agency Approvals: SC NSC WARRANTY Limited Warranty AGENCY APPROVALS 50 ft. (15.3 m) 100 ft. (30.5 m) -30 to 85 °C (-22 to 185 °F) 0.02 lbs/ft (29.7 g/m) CE; UL; RoHS compliant UL E118871; UL 13, power limited circuit cable; UL 444, communication cables; NFPA 262; plenum flame test (UL 910); NEC Articles 725 and 800; RoHS compliant 2 years 149 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com SC Dimensional Drawing 1" (25.4mm) Not > 0.25" (6.4mm) 10', 17', 25', 50', or 100' (3.1m, 5m, 7.7m, 15.3m, or 30.5m) ORDERING INFORMATION Sensing Cable MODEL U006-0009 U006-0048 U006-0013 U006-0014 U006-0010 MANUF. PART # SC-10 SC-17 SC-25 SC-50 SC-100 DESCRIPTION Sensing Cable, Water, 10 feet Sensing Cable, Water, 17 ft Sensing Cable, Water, 25 feet Sensing Cable, Water, 50 feet Sensing Cable, Water, 100 feet Leak Detection | SC & NSC NSC Dimensional Drawing 1" (25.4mm) 0.13" (3.3mm) 10', 25', 50', or 100' (3.1m, 7.7m, 15.3m, or 30.5m) ORDERING INFORMATION Non-sensing Cable MODEL U006-0017 U006-0021 U006-0022 U006-0018 MANUF. PART # NSC-10 NSC-25 NSC-50 NSC-100 DESCRIPTION Non-Sensing Cable, 10 feet Non-Sensing Cable, 25 feet Non-Sensing Cable, 50 feet Non-Sensing Cable, 100 feet 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 153 150 Leak Detection | Leak Detection Kits LC-KIT Single Zone Leak Detection Controller Kit LC-KIT Application flexibility Monitor up to 10', 17', 25' or 50' of leak detection cable Pushbutton Pushbutton switch allows users to silence the audible alarm and to test and reset the system LED indicator Bi-color LED indicator for alarm status and cable fault...easy indication of leaks or equipment problems Max accuracy Sensitivity settings for each zone help reduce false alarms... maximum detection accuracy Single zone leak detection controller kits are pre-configured in popular lengths for monitoring single areas or rooms. Kits come with everything needed for a complete system, including an LD310 single zone control panel, a leader cable kit with end-of-line terminator, sensing cable, and a WA-DC-05 power supply. LD310 control panels continuously monitor up to 300 ft. of leak detection cable. If the cable detects compatible fluid at any point along its length, the detection panel LED illuminates and an alarm signals the presence of a leak. Additionally, if the cable loses continuity, the panel will activate a cable fault LED pattern. SPECIFICATIONS LD310 Controller Input Power 5 Vdc ±10% Storage Environment -20 to 70 °C (-4 to 158 °F) Weight 3 oz. (85 g) INPUTS Water Leak Detection Cable Requires 15 ft. (4.5 m) leader cable (kit included) Maximum Cable Length 300 ft. (91 m) Detection Response Time <20 sec (10 sec typical) Relay Output 2 Form C relays (leak and fault); 1 A@24 Vdc, 0.5 A resistive@120 Vac OPERATING ENVIRONMENT Temperature 0 to 50 °C (32 to 122 °F) Humidity 5 to 95% RH non-condensing Altitude 15,000 ft. (4,572 m) max Audible alert Selectable on/off audible alert APPLICATIONS Fast response Summary alarm relay output · Monitoring data centers, computer room under-floor areas, mechanical rooms, and electrical control centers · Protecting records storage rooms · Monitoring plumbing in facilities · Monitoring chilled beams · Monitoring chemical and fuel storage areas SPECIFICATIONS Cables Plenum Rating (SC) CL2P/CMP C(UL) California State Fire Marshall approved Shear Strength >180 lbs (>81.65 kg) Cut Through Resistance >40 lbs (>18.2 kg) w/0.005" (0.13 mm) blade Abrasion Resistance 60 cycles per UL 719 Connector 4 pin, 1" (25.4 mm) dia., circular, locking, OPERATING ENVIRONMENT Temperature 0 to 75 °C (32 to 167 °F) 90 °C (194 °F) max. Humidity 5 to 95% RH non-condensing Altitude Storage Environment: SC NSC Agency Approvals: LD300 SC NSC WARRANTY Limited Warranty AGENCY APPROVALS 15,000 ft. (4,572 m) max. -30 to 85 °C (-22 to 185 °F) 0 to 75 °C (32 to 167 °F) CE; RoHS compliant CE; UL; RoHS compliant UL E118871; UL 13, power limited circuit cable; UL 444, communication cables; NFPA 262; plenum flame test (UL 910); NEC Articles 725 and 800; RoHS compliant 2 years 151 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com SINGLE ZONE KIT WITH SC SENSING CABLE Wiring Diagram LD310 WB G R Power supply (WA-DC-05 ) 15 foot Leader Cable (included with LC-KIT) SC Sensing Cable End Terminator (EOL) (10', 17', 25', 50', or 100') (included with LC-KIT) Leak Detection | LC-KIT BLINK CODE KEY LED INDICATION DEVICE STATUS Solid green (on or off) Normal operation Flashing green (0.5 sec on/2.5 sec off) Cable fault Flashing green (0.5 sec on/0.5 sec off) Leak detected ORDERING INFORMATION MODEL DESCRIPTION U006-0062 Kit, LeakDet, LD310, 10' Conductive Fluid U006-0063 Kit, LeakDet, LD310, 17' Conductive Fluid U006-0064 Kit, LeakDet, LD310, 25' Conductive Fluid U006-0065 Kit, LeakDet, LD310, 50' Conductive Fluid Cables, EOL, and power supply only. KIT INCLUDES THESE MANUF. PART #S LD310, LC-Kit, SC-10 & WA-DC-05 LD310, LC-Kit, SC-17 & WA-DC-05 LD310, LC-Kit, SC-25 & WA-DC-05 LD310, LC-Kit, SC-50 & WA-DC-05 ACCESSORIES P. 153 800.354.8556|+1 503.598.4564|sales@veris.wcowmw.|veirnitsl.@cvoemris.c|omLea|kDveertise.ccotmion | LC-KIT & LC-KIT-M 152 Leak Detection | Accessories ACCESSORIES: LEAK DETECTION U006-0024 Cross connector (1 cable input to 3 outputs) U006-0026 Replacement cable end terminators U006-0030 - J-clips (qty 10) U006-0031 - J-clips (qty 25) U006-0032 - J-clips (qty 50) U006-0033 - J-clips (qty 200) U006-0035 Leader cable kit for SC cables (connects from leak panel to SC or NSC cable) U006-0037 5 Vdc isolated power supply for LD300 U006-0084 24 Vdc isolated power supply for LD1000, LD1500, LD2100 and LDR06 153 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Leak Detection | Accessories 800.354.8556|+1 503.598.4564|sales@veris.wcowmw.|veirnitsl.@cvoemris.c|omLea|kDveertise.ccotmion | LC-KIT & LC-KIT-M 154 PRESSURE MONITORING Veris pressure sensing devices include sensors for both wet and dry media, as well as a series of electropneumatic transducers. Our products are known for their accuracy, versatility, and labor-saving installation. MODEL PX3 PASxx AFS-460 EP3 EP2 PW PW2 PWR PH PG PD DESCRIPTION Bluetooth® Differential Pressure/Air Velocity Transducers Differential Air Pressure Switches Air Pressure Sensing Switches Electropneumatic Transducers, Analog Output (V or mS, Selectable) Electropneumatic Transducers, psi Output Wet Media Differential Pressure Transducers (Selectable Pressure Units) Wet Media Differential Pressure Transducers (Dual Pressure Units) Wet Media Differential Pressure Remote Transducers Digitally Controlled Gauge Pressure Transducers Gauge Pressure Sensors Display Digital Pressure/Vacuum Gauges PAGE 157 159 161 163 165 167 169 171 173 175 177 PRESSURE SENSOR SELECTION GUIDE FEATURES/OPTIONS Analog Output Differential Pressure Sensing (Uni- and Bidirectional Operation) LCD Display Option Available Duct Mount Panel Mount Remote Mount Transmitter Only (No local display) Switch Pneumatic Systems WET MEDIA PW, PW2, PH, PG, PD pages 167, 169, 173, 175, 177 PW, PW2, PWR pages 167, 169, 171 PD, PW, PW2, PWR pages 167, 169, 171, 177 PASxx, PW, PW2, PWR pages 159, 167, 169, 171 PWR page 171 PH, PG pages 173, 175 ELECTROPNEUMATIC TRANSDUCERS FEATURES/OPTIONS Pneumatic Systems WET MEDIA DRY MEDIA PX3, PG, PD pages 157, 175, 177 PX3 page 157 PX3, PD pages 157, 177 PX3D/PX3U page 157 PX3P/PX3U page 157 PX3, PG pages 157, 175 PASxx page 159 EP3, EP2 pages 163, 165 DRY MEDIA EP2, EP3 pages 163, 165 Note: The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. Any use of such marks is under license. 155 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com PRECISE PRESSURE OR VELOCITY MEASUREMENT IN ONE DEVICE PX3 Bluetooth® Differential Pressure/Air Velocity Sensor WITH EASY BLUETOOTH CONFIGURATION! APPLICATIONS » Duct static pressure » Building or room pressure » Filter status » Air flow measurement FEATURES VERSATILE APPLICATIONS Measure either differential air pressure or velocity with the flip of a switch REDUCE FIELD FAILURES Excellent tolerance to overpressure and vibration reduces field failures WATER-RESISTANT HOUSING IP6 /NEMA 4 housing allows for mounting in wash-down locations HIGH ACCURACY High accuracy digital sensor with seven selectable pressure and eight velocity sub-ranges maintains calibration and reduces callbacks REDUCE SETUP Selectable ranges and scales reduce setup time and number of models to stock CIRCUIT PROTECTION Circuit protection avoids damage due to incorrect input wiring MAINTENANCE FREE High reliability sensor technology for long-term, maintenance-free operation Note: The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. Any use of such marks is under license. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 156 Pressure Monitoring | Dry Media Digital Pressure Transducers PX3 SERIES Bluetooth® Differential Pressure/Air Velocity Transducers PX3 Patent Pending The PX3 transducer can measure either air pressure or velocity with the flip of a switch. The PX3 is available in three installation configurations: duct, panel or universal. Duct and panel models have two pressure and velocity options: 0-1 in. WC / 0-3,000 ft/min or 1-10 in. WC / 3,000-6,000 ft/min with four field-selectable sub-ranges. The universal model comes in one pressure/velocity range: 0-10 in. WC / 0-7,000 ft/min with seven field-selectable sub-ranges for pressure and eight for velocity. All variants are available with and without display. The PX3 has an IP65/ NEMA 4 environmental rating and a 5-year limited warranty. The Veris Sensors App provides the ability to connect to a device and configure a variety of field-selectable parameters remotely from a smartphone via Bluetooth wireless technology. The app allows users to create and store commonly used parameters that will reduce commissioning time and provide assurance that all parameters are properly configured with no call backs. The app can also create a trend log while connected, providing critical data for troubleshooting purposes. iOS® users can download the app through the iOS App Store on their smart device. Android users can download the app through the Google PlayTM store. Note: The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. Any use of such marks is under license. SPECIFICATIONS GENERAL Media Dry air or inert gas Compatibility Input Power Three-wire Volt mode: 24 Vac or 12-30 Vdc* Two-wire mA mode: 12-30 Vdc* Output Power Field-selectable: 2-wire, loop-powered 4-20 mA Minimum input voltage for 4 to 20 mA operation: 250 loop = 12 Vdc; 500 loop = 19 Vdc (DC only, clipped and capped), 24 Vac/dc or 3-wire 0-5V/0-10V Minimum load resistance for Volt operation: 5 k PRESSURE RANGES 01 Pressure Range Pressure Mode: Unidirectional: 0.1/0.25/0.5/1 in. WC, switch selectable Bidirectional: ±0.1/±0.25/±0.5/±1 in. WC, switch selectable Unidirectional: 25/50/100/250 Pa, switch selectable Bidirectional: ±25/±50/±100/±250 Pa, switch selectable Velocity Mode: 500/1,000/2,000/3,000 ft/min 2.5/5/10/15 m/s Wireless configuration Reduce field failures View and configure all fieldselectable parameters via smartphone. No ladder necessary for duct mount applications. Excellent tolerance to overpressure and vibration reduces field failures High accuracy High accuracy digital sensor with seven selectable pressure and eight velocity sub-ranges, maintains calibration and reduces callbacks Water-resistant housing IP65/NEMA 4 housing allows for mounting in wash-down locations Maintenance free Circuit protection High reliability sensor technology for long-term, maintenance-free operation Circuit protection avoids damage due to incorrect input wiring APPLICATIONS · Duct static pressure (Pressure mode) · Building or room pressure (Pressure mode) · Filter status (Pressure mode) · Air flow measurement (Velocity mode) 02 Pressure Range Pressure Mode: Unidirectional: 1.0/2.5/5/10 in. WC, switch selectable Bidirectional: ±1.0/±2.5/±5/±10 in. WC, switch selectable Unidirectional: 250/500/1,000/2,500 Pa, switch selectable Bidirectional: ±250/±500/±1,000/±2,500 Pa, switch selectable Velocity Mode: 3,000/4,000/5,000/6,000 ft/min 15/20/25/30 m/s 05 Pressure Range Pressure Mode: Unidirectional: 0.1/0.25/0.5/1/2.5/5/10 in. WC, switch selectable Bidirectional: ±0.1/±0.25/±0.5/±1/±2.5/±5/±10 in. WC, switch selectable Unidirectional: 25/50/100/250/500/1,000/2,500 Pa, switch selectable Bidirectional: ±25/±50/±100/±250/±500/±1,000/±2,500 Pa, switch selectable Velocity Mode: 500/1,000/2,000/3,000/4,000/5,000/6,000/7,000 ft/min 2.5/5/10/15/20/25/30/35 m/s SENSOR Response Time Standard: T95 in 20 sec, Fast: T95 in 2 sec, DIP switch selectable Mode Unidirectional or bidirectional, DIP switch selectable Display (option) Pressure mode: Signed 3-1/2 digit LCD, indicates pressure, overrange indicator Velocity mode: Signed 4-1/2 digit LCD, indicates velocity, overrange indicator Proof Pressure 3 psid (20,600 Pa) Burst Pressure 5 psid (34,500 Pa) Pressure Mode ±1% FS (combined linearity and hysteresis) Accuracy Velocity Mode ±90 ft/min (±0.45 m/s) plus 5% of measured value** Accuracy 157 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com PPrersessusurereMMoonnitiotorirningg| |PXPX3 Series SPECIFICATIONS (CONT.) Temperature 1" (250 Pa) models: 0.05%/°C; 10" (2,500 Pa) models: 0.01%/°C Effect (Relative to 25 °C) 0 to 50 °C (32 to 122 °F) Zero Drift (1-year) 1" (250 Pa) models: 2.0% max.; 10" (2,500 Pa) models: 0.5% max. Zero Adjust Pushbutton auto-zero and digital input (2-pos terminal block) Operating Env. -20 to 60 °C (-4 to 140 °F)*** Altitude of Operation 0 to 3,000 m Humidity Range 100% RH, non-condensing Mounting Location For indoor or outdoor use (display will not function below 0 °C (32 °F)) Fittings Brass barb; 0.24" (6.1 mm) o.d. Bluetooth Frequency Range 2.402 to 2.480 GHz (Bluetooth version 4.2, enabled by DIP switch) Environmental IP65, NEMA 4 Rating Flammability UL 94 5VA fire retardant ABS, plenum rated Rating WARRANTY Limited Warranty 5 years AGENCY APPROVALS EMC Conformance: EN 61000-6-3 and A1, Class B, EN 61000-6-1, EN61326-1 and EN61326-2-3. * Class 2/II power source. ** For measured values between 200 and 7,000 ft/min (1 and 35 m/s). *** Display will not function below 0 °C (32 °F). DIMENSIONAL DRAWING in. (mm) 1.6 1.6 (42) (42) 3.5 3.5 (88) (88) WIRING DIAGRAM 2-wire, 4-20 mA Current Loop Output ZERO 70 1 2 5 6 3 4 3 4 Digital Output DIGITAL CONTROL Return V+ PWR { mA RTN 1.000 RMT. ZERO WIRING DIAGRAM 3-wire, 0-5 V/0-10 V Voltage Output ZERO 70 1 2 5 6 Digital Output DIGITAL CONTROL V IN - { 1.000 RMT. ZERO VOUT V-/GND V+/PWR - POWER SOURCE 24 Vac/dc + ORDERING INFORMATION Enclosure Local Display NIST Certificate* PX3 Range D = Duct P = Panel Example: L = LCD Display X = No Display N = NIST X = None 01 = Pressure: 0 to 1 in. WC / 0 to 250 Pa Velocity: 0 to 3,000 ft/min / 0 to 15 m/s 02 = Pressure: 0 to 10 in. WC/0 to 2500 Pa Velocity: 0 to 6,000 ft/min / 0 to 30 m/s PX3 D L X 01 *8-point calibration Local Display PX3U NIST Certificate* Range 3.1 (78) 4.4 (112) L = LCD Display X = No Display N = NIST 05 = Pressure: 0 to 10 in. WC / 0 to 2,500 Pa X = None Velocity: 0 to 7,000 ft/min / 0 to 35 m/s 0.3 (7) Example: PX3U L X 05 *16-point calibration 7.4 (188) SMART PHONE APP The Veris Sensors App allows for remote viewing and adjustment of settings. A great tool for reducing commissioning time. DRY PRES-VEL TRANS Device Info Screen Custom Config Screen Trend Log Tab ACCESSORIES VFXP Series Air Velocity Measurement Probe* Velocity Pitot Tubes, 8-5/8", 12-5/8", 18-5/8" (AA18, AA19, AA20)* Static-04 Pick-up - 4" Duct Static Pickup Probe (AA06) Static-08 Pick up - 8" Duct Static Pickup Probe) (AA07) Wall Plate Remote Pickup (AA56) *For use with the PX3P (panel) and PX3U (universal) models in Velocity mode only. VFXP Series AA18, AA19, AA20 AA06 AA07 AA56 ACCESSORIES P. 179 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 158 Pressure Monitoring | Differential Air Pressure Switches PASXX SERIES Monitor Air Ducts, Filters and Fans Easy cable lead-in Integrated cable strain relief Case geometry allows easy cable lead-in Cable strain relief integrated in PG11 (DIN 40430) High accuracy Snap cover High adjustment accuracy through User-friendly snap cover individual laser etched scale PASxx PASxx differential air flow switches are intended for use in air handling systems for the monitoring of air ducts, filters and fans. The enclosure is plastic with a rating of IP54. A set-point adjustment is provided under the clip-on clear plastic cover. Supplied complete with mounting adaptor ring, two straight duct probes and a 6-foot length of clear tubing. SPECIFICATIONS Medium Air and neutral gases Pressure range See Ordering Information table Set-point scale Inches WC Tolerable overload on one side 20 in. WC at -22 to +185 °F Repeatability PAS01 ±2.5 (0.01 in. WC) PAS02 ±5 (0.02 in. WC) PAS03 ±5 (0.02 in. WC) PAS04 ±5 (0.02 in. WC) Switching load Resistive load 5 A at 250 Vac 4 A at 30 Vdc Inductive 0.8 A at 250 Vac 0.7 A at 30 Vdc Materials in contact with the medium Case: PC 10% GF Cover: PC Diaphragm: Silicone LSR tempered 200 °C, free of gas emissions Operating temperature Medium/ ambient -22 to +185 °F (-30 to +85 °C) Storage -40 to +185 °F (-40 to +85 °C) Service life Mechanical > 106 = 1,000,000 switching cycles Electrical connection Screw terminals Cable gland type PG11 (DIN 40430) complete with cable strain relief Switch contact type SPDT (change-over) Protection standard Without IP00 cover With cover IP54 Pressure connections Pipe Ø 6.2 mm Stable switching points Long-term stability of switching points through trapezoidal bead diaphragm APPLICATIONS · High pressure monitoring · Vacuum pressure monitoring · Filter monitoring · Fan monitoring Tests/admissions WARRANTY Limited Warranty AGENCY APPROVALS EU Conformity, Electromagnetic Compatibility: CE1 conformity according to EN 60730-2-6:2008 Low Voltage Directive: 2014/35/EU Gas Appliance Directive: 2009/142/EC Pressure Sensing Devices for Gas Burners and Gas Burning Appliances: EN 1854:2010 EU Directive on RoHS: 2011/65/EU 5 years 159 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Pressure Monitoring | PASxx Series 52 (2.05) 44.4 (1.75) 25 (0.98) 60 (2.36) 78.5 (3.09) DIMENSIONAL DRAWING 91.4 (3.60) 22 (0.87) 51 (2.01) P2 P1 6.2 (0.24) 18 (0.71) 9.1 (0.36) 6 (0.24) 3.4 (0.13) 16 (0.63) 6.5 (0.26) 8 (0.32) 3.4 (0.13) 16 (0.63) 2.2 (0.09)* *Hole for PT screws KA25 INSTALLATION Mounting: · Vertical with pressure connections facing downward (factory recommended) · Horizontal with cover facing downward (switching setpoint 0.4" WC lower than scale) · Horizontal with cover facing upward (switching setpoint 0.4" WC higher than scale) WIRING 2 15.5º 49.7 (1.96) 4.5 (0.18) 4.5 (0.18) 80.8 (3.18) 88 (3.46) 53.7 (2.11) 56 (2.20) 65 (2.56) 53.7 (2.11) 4 x hole PT - screw d1 = 3.0 mm (0.12 in.) FUNCTIONALITY The pressure switch has two separate pressure chambers, each with its own connection. The switch operates when the setpoint is either exceeded or not reached. Vacuum Monitoring Connect the pressure switch via P2. Do not connect P1. Leave P1 open. Make sure that debris cannot get into P1. High Pressure Monitoring Connect the pressure switch via Pa. Do not Connect P2. Leave P2 open. Make sure that debris cannot get into P2. Filter Monitoring Connect P1 before the filter and P2 after it. Fan Monitoring Connect P1 after the fan (in blowing direction) and P2 before the fan. ORDERING INFORMATION PART NUMBER PAS01 PAS02 PAS03 PAS04 DESCRIPTION Differential Air Pressure Switch PRESSURE RANGE 0.08 to 1.2 in. WC (20 to 300 Pa) 0.2 to 2.0 in. WC (50 to 500 Pa) 0.4 to 4.0 in. WC (100 to 1000 Pa) 2.0 to 8.0 in. WC (500 to 2000 Pa) ACCESSORIES Static-04 Pick-up - 4" Duct Static Pickup Probe (AA06) Static-08 Pick up - 8" Duct Static Pickup Probe) (AA07) 1 3 1 = COM (Common) 2 = NC Contact (Normally Closed) 3 = NO Contact (Normally Open) AA06 AA07 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 160 Pressure Monitoring | Air Pressure Sensing Switch AFS-460 Multi-purpose Manual Reset DPDT Air Pressure Sensing Switch Sense positive, negative or for 120 Vac or 24 Vac Applications differential air pressure Field adjustable Field adjustable set point range of 0.40 ± 0.06" WC to 12.0" WC Durable Enclosure cover Housed in a plated enclosure with removable metal guard protecting set point screw and snap action switch terminals Avoid accidental contact with the live switch AFS-460-136 The AFS-460 is a general purpose airflow proving switch designed for 120 Vac (AFS-460-136) or 24 Vac (AFS-460-137) HVAC and Energy Management applications where a manual reset switch with DPDT contacts is desirable. It may be used to sense positive, negative, or differential air pressure. The plated housing contains a diaphragm, a calibration spring, a snapacting switch with manual reset button, and a DPDT relay. The sample connections located on each side of the diaphragm accept 0.25" OD tubing via the integral compression ferrule and nut. An enclosure cover guards against accidental contact with the live switch terminal screws and the set point adjusting screw. The enclosure cover will accept a 0.5" conduit connection. The manual reset button is located on the top surface of the enclosure cover. APPLICATIONS · Proving fan status · Monitoring filter for excess pressure drop SPECIFICATIONS Sample Media Mounting Position (to meet lowest operating specifications) Field Adjustable Range Maximum Pressure Operating Temperature Range Electrical Rating Contacts Electrical Connections Sample Line Connections Shipping Weight Agency Approvals Limited Warranty Air or combustion by-products that will not degrade silicone Diaphragm in any vertical plane 0.40 ± 0.06" WC to 12.0" WC 0.5 psi (0.03 bar) -40 to 180 °F (-40 to 82 °C) AFS-460-136: 4.5 VA @ 120 Vac, 50/60 Hz AFS-460-137: 0.5 VA @ 24 Vac, 50/60 Hz DPDT, 2 form-C rated 8 A @ 250 Vac Screw terminals Ferrule and nut compression type connectors will accept 0.25" OD rigid tubing 1.2 pounds Pending 2 years · Monitoring duct static pressure · Proving air flow · Monitoring damper status 161 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING in. (mm) Pressure Monitoring | AFS-460 WIRING DIAGRAM ORDERING INFORMATION Voltage AFS-460 - 136 = 120 Vac applications 137 = 24 Vac applications Example: AFS-460- 136 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 179 162 Pressure Monitoring | Electropneumatic Transducers EP3 SERIES Micro-Controlled with High-Performance, Low-Power Coil Poppet Valve Technology EP3 EP Series transducers are sold as an open device. Observe handling precautions for static sensitive devices to avoid damage to the circuitry which would not be covered under the factory warranty. Field-selectable Field-selectable 4 to 20 mA/ 0-5 V/0-10 Vdc input for application flexibility Multi-point calibration 3 to 15 psi (5-point calibration) and 0 to 20 psi (6-point calibration) Quiet operation Poppet valve technology for quiet operation Pressure loss alarm Pressure loss alarm provides a contact closure if the EP3 is unable to achieve the desired output within a fixed length of time Manual override Manual override with set and hold feature...great for commissioning leaky systems Fail-safe vent Fail-safe vent solenoids bleed branch pressure on power failure for added safety The EP3 Series combines a microcontroller with high performance, low power coil poppet valve technology to create a system with unparalleled accuracy and proven reliability. The poppet valves used in the EP3 consume no air, eliminating unnecessary air losses in the system and allowing for efficient, long-term operation. The EP3 permits versatility, since all models feature manual override and a tri-state control option. The LCD provides easy visibility and the LED indicators provide visual status of valve operation in manual or automatic mode. All models come with SnapTrack housing and optional covers are available. APPLICATIONS · Hospitals · Schools · Pneumatic dampers/actuators SPECIFICATIONS GENERAL Input Power Control Input Input Impedance Manual Override Alarm Contact Accuracy Temperature Coefficient Operating Temp Range Operating Hum. Range SCIM Supply Pressure Class 2; 22 to 30 Vdc/20 to 30 Vac, 47 to 63 Hz,150 mA max. average, 350 mA peak Class 2; 4 to 20 mA/0-5 V/0-10 Vdc; switchselectable, Tri-State, PWM 4 to 20 mA, 250 ; 0-5 V/0-10 Vdc, 10 k Digital pushbutton adjust, jumper-selectable mode 100 mA@30 Vac/dc (Pressure loss, manual mode, jumper selectable) 1% FS; combined linearity, hysteresis, repeatability @20 °C (68 °F) ambient ±0.1%/°C 41 to 140 °F (5 to 60 °C) 10 to 90% RH non-condensing 523 in3/min @ 45 psi; (8570 cm3/min @ 310.3 kPa); 333 in3/min @ 20 psi (5457 cm3/min @ 137.9 kPa) Min (0.1 psi + user F.S. pressure); Max 45 psig Control Range Pressure Differential Pressure Indication Min. Tubing Length Port Connection Media Connection WARRANTY Limited Warranty AGENCY APPROVALS ** User programmable zero selectable from 0 to 25 psi: Full scale 0 to 25 psi 0.1 psig (supply to branch) Electronic, 3-½ digit backlit LCD 15 feet* 1/8" I.D. poly tubing Clean, dry air, or inert gas. Do not use with oxygen service 5 years *For shorter tubing runs use the Veris AA45 Pneumatic Capacitor EMC Conformance: Low voltage directive 2014/35/EU; EMC directive 2014/30/EU. EMC Special Note - CE option: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). **The CE mark applies to models with cover only. 163 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com CURRENT/VOLTAGE CONTROL Wiring Diagrams Pressure Monitoring | EP3 Series DIMENSIONAL DRAWINGS · Input switch set to voltage (0 to 5 Vdc or 0 to 10 Vdc) · Input volt jumper set to either 0 to 5 Vdc or 0 to 10 Vdc · Input switch set to 4 to 20 mA · Output jumper set to 0 to 10 Vdc TRI-STATE CONTROL Wiring Diagrams DUST COVER Dimensional Drawings (Front View) Side View CONFIGURATION · Input switch set to "TRI-STATE" · Tri-state jumper set to "ON" ORDERING INFORMATION Output EP3 Failsafe 3 S 0 = None 3 = Analog output: 0-10VDC, or 4-20mA, selectable 0 = None 1 = Vent on Power Fail *Sold separately as AA43. Example: EP3 0 3 0 S 2 Option = Cover Plate Option Blank = None 2 = EP Cover Plate* INPUT 4-20mA Voltage Tri-State PWM Network Control GND INPUT 24V CH2 CH1/PW INPUT VOLTAGE 0-10V 0-5V TRI-PULL-UP ON OFF OPERATING MODE ALARM P-LOSS MAN OUTPUT SETTING 4-20mA 0-10V Tri-State Timing Network FS Point Zero RUN Auto Manual ALARM OUTPUT 4-20mA/0-10V -+ Subtract Pressure Add Pressure TRISTATE ACCESSORIES Dust Cover (AA43) Pneumatic Capacitor(AA45) Triac adapter (AA49) AA43 AA45 AA49 ACCESSORIES P. 179 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 164 Pressure Monitoring | Electropneumatic Transducers EP2 SERIES Micro-Controlled with High-Performance, Low-Power Coil Poppet Valve Technology Field selectable Field-selectable 4 to 20 mA/ 0-5 V/0-10 Vdc input for application flexibility Multi-point calibration Multi-point calibration; 3 to 15 psi (5-point calibration) and 0 to 20 psi (6-point calibration) Quiet operation Poppet valve technology for quiet operation Pressure loss alarm Pressure loss alarm provides a contact closure if the EP2 is unable to achieve the desired output within a fixed length of time EP2 EP Series transducers are sold as an open device. Observe handling precautions for static sensitive devices to avoid damage to the circuitry which would not be covered under the factory warranty. Manual override Manual override with set and hold feature...great for commissioning leaky systems Fail-safe vent Fail-safe vent solenoids bleed branch pressure on power failure for added safety The EP2 Series electropneumatic pressure transducer uses microcontrolled poppet valve technology for highly accurate pressure sensing in multiple applications. The poppet valves consume no air, eliminating unnecessary air losses in the system and allowing for stable and reliable operation. The EP2 comes installed on standard SnapTrack, and an optional dust cover is available to protect from the environment. An LCD display and LED indicators make it easy to read system status at a glance. APPLICATIONS · Hospitals · Schools · Pneumatic dampers/actuators SPECIFICATIONS GENERAL Input Power Control Input Input Impedance Manual Override Alarm Contact Accuracy Compensated Temp Range Temperature Coefficient Operating Environment Air Capacity Supply Pressure Control Range Pressure Differential Pressure Indication Class 2; 24 Vac/dc nominal, 30 Vac max.; 150 mA max. Class 2; 4 to 20mA/0-5 V/0-10 Vdc; jumper-selectable 4 to 20 mA, 250 ; 0-5 V/0-10 Vdc, 10 k Jumper-selectable mode, digital pushbutton adjust 100 mA@30 Vac/dc (pressure loss, manual mode, jumper selectable) 1% FS; combined linearity, hysteresis, repeatability -4 to 65 °C (25 to 140 °F) ±0.05%/°C 10 to 90% RH non-condensing 523 in3/min @ 45 psi (8570 cm3/min @ 310.3 kPa); 333 in3/min @ 20 psi (5456 cm3/min @ 137.9 kPa) 45 psig max. 0 to 20 psig or 3 to 15 psig, jumper-selectable 0.1 psig (supply to branch) Electronic, 3-1/2 digit LCD Minimum Tubing Length Port Connection Media Connection WARRANTY Limited Warranty AGENCY APPROVALS ** 15 feet* 1/8" I.D. poly tubing Clean, dry air, or inert gas. Do not use with oxygen service 5 years *For shorter tubing runs use AA45 Pneumatic Capacitor EMC Conformance - CE option: Low voltage directive 2014/35/EU; EMC directive 2014/30/EU. EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). **The CE mark applies to models with cover only. 165 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com WIRING DIAGRAM Pressure Monitoring | EP2 Series DIMENSIONAL DRAWINGS 3.3" (84 mm) GND/COM INPUT SIGNAL POWER Current Voltage 0-5V 0-10V 0-20psi 3-15psi Auto Manual ON OFF FROM CONTROL SYSTEM GND/COMMON INPUT SIGNAL POWER TO DIGITAL INPUT - OPTIONAL PRESSURE LOSS ALARM CONFIGURATION MANUAL ADJUST INPUT VOLTAGE MODE MODE OPERATION PRESSURE MODE ALARM RANGE MODE PRESSURE LOSS ALARM (OPTIONAL) 3.5" (89 mm) 1.8" (46 mm) DUST COVER Dimensional Drawings (Front View) 4.9" (125 mm) Side View 2.1" (53 mm) ORDERING INFORMATION Output Feedback Failsafe EP2 1 S = Selectable 3-15/0-20 psi 0 = None 1 = Pressure Loss Alarm 2 = Manual Mode Alarm 0 = None 1 = Vent on Power Fail *Sold separately as AA43. Example: EP2 1 0 0 S 2 Option = EP cover plate If the dust cover is ordered, the EP2 is mounted to a longer Snaptrack. Option Blank = none 2 = EP Cover Plate* ACCESSORIES Dust Cover (AA43) Pneumatic Capacitor(AA45) AA43 AA45 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 179 166 Pressure Monitoring | Wet Media Differential Pressure Transducers PW SERIES DIP Switch Selectable Port Swap Feature Flexible The DIP switch selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility Switch-selectable Switch-selectable pressure ranges...fewer models to order and stock Rugged Rugged, die-cast enclosure provides NEMA 4 sealing High stability DIP switch controlled electronic surge dampening PWxxxS PWxxxBP The PW Series wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability. Easy to use and designed to provide exceptional installation savings, the PW Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors, and other non-corrosive wet media applications. The DIP switch selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed, allowing the DIP switch position to be changed from normal to swap. The optional pre-assembled bypass valve is designed for easy maintenance and one-step installation. SPECIFICATIONS GENERAL Input Power Class 2; 15 to 30 Vdc, 24 Vac nom. 50/60 Hz* Max. Current Draw DC: 125 mA; AC: 280 mA Output 3-wire transmitter; user selectable 4 to 20 mA (clipped & capped)/0-5 V/0-10 V* Surge Damping Electronic; 1 or 5 second averaging Test Mode Overrides output to full-scale (20 mA, 5 V, 10 V) Zero Adjust Pushbutton auto-zero & digital input (2-pos terminal block) Status Indication Dual-color LED: Green = Normal, Green Blinking = Low > High Red = Overrange, Red Blinking = Overpressure Green/Red Blinking = Underpressure Zero Offset (Bidirectional and Port Swap modes only) 0.5% Housing Material White powder-coated aluminum NEMA 4, IP65 Fittings 1/8" NPT female thread, 17 to 4 PH stainless steel PRESSURE RANGES (SELECTABLE) 0 to 50 psig (Gauge) 0 to 5/10/25/50 psid (Differential) 0 to 100 psig (Gauge) 0 to 10/20/50/100 psid (Differential) 0 to 250 psig (Gauge) 0 to 25/50/125/250 psid (Differential) SENSOR Accuracy @ 25 °C** Ranges A and B: ±1% F.S. typical***; Range C: ±1.5% F.S. typical***; Range D: ±2% F.S. typical*** Zero calibration Pushbutton and remote zero adjustment...maintain accuracy and reduce callbacks with automatic zero calibration APPLICATIONS · Monitoring and controlling pump differential pressure · Chiller/boiler differential pressure drop · CW/HW system differential pressure Long Term Stability Media Compatibility Proof Pressure Burst Pressure Temperature Compensated Range Media Temp. Limits Operating Environment WARRANTY Limited Warranty AGENCY APPROVALS ±0.25% per year Media compatible with 17 to 4 PH stainless steel 2x max. F.S. range*** 5x max. F.S. range*** 0 to 50 °C (32 to 122 °F); TC Zero <±1.5% of product F.S.*** per sensor ; TC Span<±1.5% of product F.S.*** per sensor, (2 sensors per unit) -20 to 85 °C (-4 to 185 °F); 0 to 90% RH non-condensing -10 to 50 °C (14 to 122 °F); 10 to 90% RH non-condensing 5 years *VFD systems and system wiring generate fields that can disrupt electrical devices. Ensure that these fields are minimized and are not affecting the sensor or sensor wiring. **Accuracy combines linearity, hysteresis, and repeatability. *** FS is defined as full span of selected range in bi-directional mode. EMC Conformance - Low voltage directive 2014/35/EU; EMC directive 2014/30/EU. EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). 167 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Pressure Monitoring | PW Series WIRING DIAGRAM POWER SOURCE 15 to 30 Vdc/24 Vac DIGITAL CONTROL Analog Input: 0 to 5 V/0 to 10 V or 4 to 20 mA Optional Digital Output POWER SIGNAL COM DIMENSIONAL DRAWING PW Series (PWxxxS) WET DIFFERENTIAL PRESSURE Zero Button mA Remote Zero Volt (Dry Contact) ON OFF 1 2 3 4 5 6 Range A B Status LED C D Power Shield Signal Common Low Sensors Hi 2.2" (57 mm) 4" (102 mm) Range Model A B C D -03 50 25 10 5 -04 100 50 20 10 -05 250 125 50 25 DIP Switches Num Function O /On1 1 Damping Fast/Slow 2 Test Operate/Test 3 Mode Normal/Bidirec. 4 Analog Normal/Reverse 5 Port Normal/Swap 6 Voltage Out2 0 to 10 V/0 to 5 V 1. "O " position is the default setting for all DIP switches. 2. Ignored in mA mode. DIMENSIONAL DRAWING PW Series with Optional Mounted Bypass Assembly (PWxxxBP)* 8.7" (221 mm) 6.75" (172 mm) 1.5" (38 mm) 0.5" (13 mm) 0.3" (8 mm) 3.5" (89 mm) 12.0" (305 mm) LOW HIGH 5.8" (147 mm) MICROPROCESSOR PROVIDES DIGITAL SIGNAL CONDITIONING · Noise rejection reduces · Surge damping prevents false fluctuating readings due to alarms by averaging fast peaks noise or turbulence F.S. Noise Rejection Output Clamping 3.5" (89 mm) 7.75" (191 mm) 8.7" (221 mm) 1.0" (25 mm) 0.4" (11 mm) * Bypass valve assembly also sold separately as AA14A. 1.8" (46 mm) PRESSURE Surge Damping 0 Actual Pressure TIME ORDERING INFORMATION Digitally Conditioned Output Local Display PW NIST Operational Range* Options L = LCD display X = No display N = NIST X = None Example: PW L X 04 S 03 = 0-50 psig 04 = 0-100 psig 05 = 0-250 psig S = Standard BP = With mounted bypass assembly** ACCESSORIES Brass Snubber, 1/8" NPT (AA11) Brass Snubber, 1/4" NPT (AA69) Stainless Steel Snubber, 1/8" NPT (AA12) Stainless Steel Snubber, 1/4" NPT (AA70) Pigtail Steam Siphon (AA13) * Select operational range according to maximum gauge pressure, NOT differential pressure. ** B ypass valve assembly also sold separately as AA14A. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com AA11/AA69 AA12/AA70 AA13 ACCESSORIES P. 179 168 Pressure Monitoring | Wet Media Differential Pressure Transducers PW2 SERIES 4 to 20 mA, 2-Wire Devices Jumper selectable Dual sensor The jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility Dual sensor design for improved overpressure tolerance... eliminates the requirement for a bypass valve assembly in most applications PW2xxxS PW2xxxBP The PW2 Series 2-wire, 4 to 20 mA wet pressure transducers incorporate microprocessor profiled sensors for exceptional accuracy and reliability. Easy to use and designed to provide exceptional installation savings, the PW2 Series is ideal for measuring pressure across pumps, filters, heat exchangers, compressors, and other non-corrosive wet media applications. The optional pre-assembled bypass valve is designed for easy maintenance and a one-step installation. SPECIFICATIONS GENERAL Input Power Class 2; 12 to 24 Vdc, loop powered (polarity insensitive) Maximum Current Draw 29 mA Output 2-wire transmitter; user selectable 4 to 20 mA (clipped & capped)* Surge Damping Electronic; 5-second averaging Zero Adjust Pushbutton auto-zero terminals Housing Material White powder-coated aluminum PRESSURE RANGES (SELECTABLE) 0 to 50 psi (0 to 3.45 barg) 0-5/10/25/50 psid (0-0.34/0.69/1.72/3.45 bard) (Gauge) (Differential) 0 to 100 psig (0 to 6.89 barg) (Gauge) 0-10/20/50/100 psid (Differential) (0-0.69/1.38/3.45/6.89 bard) (Differential) 0 to 250 psi (0 to 17.24 bar) 0-25/50/125/250 psid (Differential) (Gauge) (0-1.72/3.45/8.62/17.24 bard) (Differential) SENSOR Accuracy @ 25 °C** Range A, B, C: ±1% F.S.; Range D: ±2% F.S.*** Media Compatibility Media compatible with 17-4 PH stainless steel Long Term Stability ±0.25% per year Proof Pressure Max. 2x F.S. range Burst Pressure Max. 5x F.S. range Temperature Compensated Range 0 to 50 °C (32 to 122 °F); TC Zero <±1.5% of product F.S. per sensor ; TC Span<±1.5% of product F.S. per sensor, (2 sensors per unit) Media Temperature Limits -20 to 85 °C (-4 to 185 °F); 0 to 90% RH non-condensing Rugged Rugged, die-cast enclosure provides NEMA 4 sealing High stability Jumper-controlled electronic surge dampening for high stability Selectable Selectable differential units: psid or bard APPLICATIONS · Monitoring and controlling pump differential pressure · Chiller/boiler differential pressure drop Zero calibration Pushbutton zero calibration no trim pots to adjust...maintain accuracy and reduce callbacks with automatic zero calibration · CW/HW system differential pressure Product Operating Environment WARRANTY Limited Warranty AGENCY APPROVALS -10 to 55 °C (14 to 130 °F); 0 to 90% RH non-condensing 5 years * Minimum input voltage: 250 loop = 12 Vdc; 500 loop = 17 Vdc **Accuracy combines linearity, hysteresis, and repeatability. ***FS is defined as full span of selected range in bi-directional mode. EMC Conformance - Low voltage directive 2014/35/EU; EMC directive 2014/30/EU. EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1 specification requirements). MICROPROCESSOR PROVIDES DIGITAL SIGNAL CONDITIONING · Noise rejection reduces · Surge damping prevents false fluctuating readings due to alarms by averaging fast peaks noise or turbulence F.S. Noise Rejection Output Clamping PRESSURE Surge Damping 0 Actual Pressure TIME Digitally Conditioned Output 169 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Pressure Monitoring | PW2 Series WIRING DIAGRAM Polarity Insensitive POWER SOURCE 12 to 24 Vdc 4 to 20mA IN DIGITAL CONTROL Digital Output ZERO REMOTE 4 to 20 mA ZERO A-High B-Mid High C-Mid Low D-Low Pressure Range Port Swap/Norm Bi-Dr/Normal Slow Avg/Fast Norm Analog Rev/Norm Bar/PSI Settings Default Settings in bold. Insert jumper to activate other features. Range (psi) Model A B CD PW2-03 50 25 10 5 PW2-04 100 50 20 10 PW2-05 250 125 50 25 Range (bar) Model A B CD PW2-03 3.45 1.72 0.69 0.34 PW2-04 6.89 3.45 1.38 0.69 PW2-05 17.24 8.62 3.45 1.72 Bidirectional Operation Input Conditions HI PORT 100 psi 100 psi 50 psi 50 psi 0 psi LO PORT 0 psi 50 psi 50 psi 100 psi 100 psi Result DP +100 psi +50 psi 0 psi -50 psi -100 psi Outputs Read 4-20mA 20mA 16mA 12mA 8mA 4mA DIMENSIONAL DRAWING PW2xxxS 2.2" (57 mm) DIMENSIONAL DRAWING PW2xxxBP* 8.7" (221 mm) 6.75" (172 mm) 1.5" (38 mm) 0.5" (13 mm) 0.3" (8 mm) 3.5" (89 mm) 12.0" (305 mm) WET DIFFERENTIAL PRESSURE 4" (102 mm) 3.5" (89 mm) LOW HIGH 5.8" (147 mm) ORDERING INFORMATION Local Display PW2 NIST Operational Range* Options L = LCD Display X = No Display N = NIST X = None Example: PW2 L X 04 S 03 = 0 to 50 psig/3.45 barg S = Standard 04 = 0 to 100 psig/6.89 barg BP = With mounted 05 = 0 to 250 psig/17.24 barg bypass assembly** *Select operational range according to max. gauge pressure, NOT differential pressure. Example: High gauge pressure =90 psig, Select 100 psig model (04). ** B ypass valve assembly also sold separately as AA14A. 7.75" (191 mm) 8.7" (221 mm) 1.0" (25 mm) 0.4" (11 mm) * Bypass valve assembly also sold separately as AA14A. 1.8" (46 mm) ACCESSORIES Brass Snubber, 1/8" NPT (AA11) Brass Snubber, 1/4" NPT (AA69) Stainless Steel Snubber, 1/8" NPT (AA12) Stainless Steel Snubber, 1/4" NPT (AA70) Pigtail Steam Siphon (AA13) AA11/AA69 AA12/AA70 AA13 ACCESSORIES P. 179 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 170 Pressure Monitoring | Wet Media Differential Pressure Remote Transducers PWR SERIES 3-Wire Device, User-Selectable Output PWR Armor cable Armor cable or conduit connector minimizes the need for field customization Zero calibration Pushbutton zero calibration no trim pots to adjust...maintain accuracy and prevent callbacks with automatic zero calibration Lower costs Remote probes reduce need for plumbing or bypass assemblies... lower costs and reduced labor for installation Switch-selectable Switch-selectable pressure ranges...fewer models to order and stock The PWR Series remote wet media pressure transducers allow remote pressure sensing capability using existing plumbing runs. With no need to run plumbing lines all the way to the transducer, the installation time and cost is greatly reduced. Select either armored (6 ft.) or shielded (10 or 20 ft.) cable, depending on the application. APPLICATIONS · Monitoring and controlling pump differential pressure · Chiller/boiler differential pressure drop · CW/HW system differential pressure SPECIFICATIONS GENERAL Input Power Maximum Current Draw Output Status Indication Surge Damping Zero Adjust Fittings SENSOR Media Compatibility Proof Pressure Burst Pressure Accuracy at 25 °C*** Long Term Stability Zero Offset (Bidirectional and Port Swap Modes Only) Temperature Compensated Range Class 2; 15 to 30 Vdc, 24 Vac nom. 50/60 Hz* DC: 125 mA; AC: 280 mA 3-wire transmitter; user-selectable 4 to 20mA/ 0 to 5 V/0 to 10 V Dual color LED Electronic; 1 or 5 second averaging Pushbutton auto-zero and digital input (2-position terminal block) 1/4" NPT male thread, stainless steel 17-4 PH Overall thread length: 0.5946" (conforms to ANSI/ASME B1.20.1 standard) 17-4 PH stainless steel 2x max. F.S. range** 5x max. F.S. range** Ranges A and B: ±1% F.S. typical; Range C: ±1.5% F.S. typical; Range D: ±2% F.S. typical. (For less than or equal to 20 ft. (6.1 m) cable length) ±0.25% ±0.5% 0 to 50 °C (32 to 122 °F); TC Zero <1.5% of product F.S. per sensor; TC Span <1.5% of product F.S. per sensor PRESSURE RANGES 0 to 50 psig (Gauge) 5/10/25/50 psid (Differential) 0 to 100 psig (Gauge) 10/20/50/100 psid (Differential) 0 to 250 psig (Gauge) 25/50/125/250 psid (Differential) OPERATING CONDITIONS Sensor Operating Range -20 to 85 °C (-4 to 185 °F) Operating Environment -10 to 50 °C (14 to 122 °F); 10 to 90% RH non-condensing WARRANTY Limited Warranty 5 years COMPLIANCE INFORMATION Approvals RoHS, CE, NEMA4, IP65 at sensor *VFD systems and system wiring generate fields that can disrupt electrical devices. Ensure that these fields are minimized and are not affecting the sensor or sensor wiring. **F.S. is defined as full span of selected range. ***Accuracy combines linearity, hysteresis, and repeatability. 171 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Pressure Monitoring | PWR Series WIRING DIAGRAM POWER SOURCE 15 to 30 Vdc/24 Vac DIGITAL CONTROL Analog Input: 0 to 5 V/0 to 10 V or 4 to 20 mA Optional Digital Output POWER SIGNAL COM DIMENSIONAL DRAWING 170 mm (6.7") Zero Button mA Remote Zero Volt (Dry Contact) ON OFF 1 2 3 4 5 6 Range A B Status LED C D Power Shield Signal Common Low Sensors Hi Range Model A B C D -03 50 25 10 5 -04 100 50 20 10 -05 250 125 50 25 DIP Switches Num Function O /On1 1 Damping Fast/Slow 2 Test Operate/Test 3 Mode Normal/Bidirec. 4 Analog Normal/Reverse 5 Port Normal/Swap 6 Voltage Out2 0 to 10 V/0 to 5 V 1. "O " position is the default setting for all DIP switches. 2. Ignored in mA mode. 78 mm (3.1") 61 mm (2.4") ORDERING INFORMATION Display PWR L = LCD Display NIST Operational Range* X = None 03 = 0-50 psig 04 = 0-100 psig 05 = 0-250 psig Example: PWRLX 03 S 006 A Media Cable Length S = Water 006 = 6 ft. (1.8 m) 010 = 10 ft. (3.1 m) 020 = 20 ft. (6.1 m) Cable Blank = Standard** A = Armored*** * Select operational range according to maximum gauge pressure, NOT differential pressure. Example: High gauge pressure=90 psig, Select 100 psig model (04). ** Standard cable available only in 10 ft and 20 ft lengths. *** Armored cable available only in 6 ft length. Note: Extension of total cable length greater than 20 feet may result in reduced accuracy. ACCESSORIES Brass Snubber, 1/4" NPT (AA69) Stainless Steel Snubber, 1/4" NPT (AA70) Pigtail Steam Siphon (AA13) 1/4" Ball Valve (AA68) AA69 AA70 AA13 AA68 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 179 172 Pressure Monitoring | Digitally Controlled Gauge Pressure Transducers PH SERIES Three Switch-Selectable Ranges with Test Mode Reduces failures Micromachined silicon sensor design...improves overpressure capacity and reduces failures Switch-selectable Switch-selectable pressure ranges...fewer models to order and stock High stability Electronic surge damping for high stability Pushbutton Pushbutton and remote zero adjustment...maintain accuracy and prevent callbacks with automatic zero calibration Zero calibration Microprocessor Pushbutton zero calibration... Microprocessor controlled signal no trim pots to adjust, saves conditioning (see graph) PH installation time The PH Series pressure transducers are designed for steam, air, gas, and liquid pressure measurement in all media compatible with 17-4PH N8 stainless steel. They utilize a microprocessor controlled sensor profiled for exceptional accuracy and reliability. All models feature three switchselectable ranges and a "test mode" to verify wiring and panel input scaling. A pushbutton and digital input terminal is used to automatically zero the output, and the microprocessor guards against accidental zero adjustment during operation. The field-selectable output, offering options of 0 to 5 V, 0 to 10 Vdc, or 4 to 20 mA, ensures excellent systems compatibility. Jumper controlled surge damping is provided on all models to reduce false alarms. APPLICATIONS · Chilled and hot water pump monitoring · HVAC and industrial gas monitoring · Instrument air pressure · Hydraulic oil pressure SPECIFICATIONS GENERAL Input Power Output Surge Damping Test Mode Zero Adjust Status Indication Housing Material PRESSURE RANGES 0 to 100 psi 0 to 250 psi 0 to 500 psi 0 to 1000 psi OTHER SPECS Product Operating Environment Class 2; 12 to 30 Vdc/24 Vac 3-wire transmitter; user selectable 4 to 20 mA (clipped & capped)/0-5 V/0-10 V* Electronic; 5-second averaging Overrides output to full-scale (20 mA, 5 V, 10 V) Pushbutton auto-zero and digital input (2-pos terminal block) Dual-color LED: Green = Normal, Red = Overpressure, Flashing Red = Fault White powder-coated steel 25/50/100 psig switch selectable 62.5/125/250 psig switch selectable 125/250/500 psig switch selectable 250/500/1000 psig switch selectable -10 to 55 °C (-4 to 130 °F); 0 to 90% RH non-condensing SENSOR Accuracy Long Term Stability Media Compatibility Proof Pressure Burst Pressure Temp Compensated Range Media Temperature Limits Fittings WARRANTY Limited Warranty ±1% F.S. Combined linearity, hysteresis, and repeatability ±0.25% per year Media compatible with 17-4 PH stainless steel Max. 2x F.S. range Max. 5x F.S. range 0 to 50 °C (32 to 122 °F) -20 to 85 °C (-4 to 185 °F); 0 to 90% RH non-condensing 1/4" NPT male thread, 17-4 PH stainless 5 years *Minimum input voltage for 4 to 20 mA operation: 250 loop (1 to 5 V) = 12 Vdc 500 loop (2 to 10 V) = 15 Vdc 173 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com WIRING DIAGRAM + POWER SOURCE 12 to 30 Vdc/24 Vac - DIGITAL CONTROL - Analog Input 0 to 5 V/0 to 10 V or 4 to 20 mA Optional Digital Output Zero VIN Response OUT Slow COMMON Fast Remote Zero A B C TEST Range VOLT mA Output 0-5 0-10 MODEL 07 08 09 10 RANGE A BC 25 50 100 62.5 125 250 125 250 500 250 500 1000 SIGNAL CONDITIONING DIAGRAM F.S. Noise Rejection Output Clamping PRESSURE Surge Damping 0 Actual Pressure TIME Digitally Conditioned Output Pressure Monitoring | PH Series DIMENSIONAL DRAWING 2.25" (57 mm) 5.1" (129 mm) 4.5" (115 mm) 2.5" (62 mm) 2.2" (56 mm) ORDERING INFORMATION NIST Range PH S N = NIST X = None 07 = 0-100 psig 08 = 0-250 psig 09 = 0-500 psig 10 = 0-1000 psig = Standard Example: PH X 07 S ACCESSORIES Brass Snubber, 1/4" NPT (AA69) Stainless Steel Snubber, 1/4" NPT (AA70) Pigtail Steam Siphon (AA13) AA69 AA70 AA13 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 179 174 Pressure Monitoring | Gauge Pressure Sensors PG SERIES Rugged Stainless Steel Construction PG Versatile A wide operating temperature range of -40 to 85 °C (-40 to 185 °F) for operation versatility Sturdy construction Suitable for high shock and vibration applications Fewer parts to fail Rugged No silicon oil, no internal O-rings, Stainless steel wetted no welds construction The PG Series pressure transducers are compatible with a variety of HVAC and industrial applications, such as refrigeration measurement, pneumatic pressure measurement, gas pressure measurement, pump inlet, and outlet fluid pressure. They are also compatible with extreme applications, such as aerospace and motor sports equipment. Volt and mA output options ensure integration with building systems. A wide selection of pressure ranges offers application flexibility. The PG Series offers a stainless steel housing and all models are warranted for a period of five years. APPLICATIONS · Pump inlet/outlet and compressors · Hydraulic/pneumatic systems · Energy and water management · Refrigeration equipment, fluids · Gas pressure measurement SPECIFICATIONS GENERAL Supply Voltage Class 2; 12 to 30 Vdc Output 0 to 5 Vdc (3-wire), 0 to 10 Vdc (3-wire) or 4 to 20 mA (2-wire) Load Impedance Volt models >10 k mA models 250 with 12 Vdc min. supply voltage mA models 500 with 17 Vdc min. supply voltage Standard Connection Cable gland 59" (1.5 m) length Pressure Port 1/4" NPT Male PERFORMANCE AT 25 °C (77 °F) Accuracy * ±0.5% FS Media Compatibility Fluids & gases compatible with 316L stainless steel Pressure Cycles >100 million cycles Over Pressure 2.5x FS with no change in calibration ENVIRONMENTAL Shock 100G, 11 msec, 1/2 sine Vibration 20G peak, 20 to 2400 Hz EMI/RFI Protection Yes Rating IP66 Operating Temp. Range -30 to 120 °C (-22 to 248 °F) Compensated Temp Range 0 to 55 °C (32 to 130 °F) Total Error Band Over Temp <±3% of FS Humidity WARRANTY Limited Warranty AGENCY APPROVALS 0 to 95% RH non-condensing 5 years * Accuracy includes nonlinearity and hysteresis. 175 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 3-WIRE, 0-5 VDC/0-10 VDC Wire Color Coding Brown (+) White (-) Green (Output) 2-WIRE, 4 TO 20 MA Wire Color Coding Brown (+) Green (Output) Pressure Monitoring | PG Series DIMENSIONAL DRAWING Jacketed Cable length = 4.9 ft (1.5 m) NPT 17/18 in. (24 mm) ORDERING INFORMATION Range Wetted Material Output PG A 03 = 0 to 15 psig 04 = 0 to 25 psig 05 = 0 to 50 psig 06 = 0 to 75 psig 07 = 0 to 100 psig 08 = 0 to 250 psig 09 = 0 to 500 psig = 316L stainless steel M = 4 to 20 mA V = 0-10 Vdc J = 0-5 Vdc Call factory for ranges not shown. Example: PG 07 A V ACCESSORIES Brass Snubber, 1/4" NPT (AA69) Stainless Steel Snubber, 1/4" NPT (AA70) Pigtail Steam Siphon (AA13) AA69 AA70 AA13 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 176 Pressure Monitoring | Digital Display Pressure/Vacuum Gauges PD SERIES Rugged, One-Piece Construction PD Multiple pressure range options Fits a wide variety of application needs Switch-selectable Switch-selectable scales... for maximum resolution and versatility Rugged Rugged one-piece construction... provides long product life Pushbutton zero Maximizes accuracy and prevents callbacks Large LCD display NEMA 4/IP65 Clear readings at a distance NEMA 4/IP65 housing The versatile PD Digital Pressure Gauge can be used with any gas, liquid, or solid that is compatible with 17-4 stainless steel. The one-piece construction employs no silicone oil, welds, O-rings, or seals, making it the ideal universal pressure measurement device. The large LCD display shows the current reading, the selected scale, and the maximum and minimum pressure. All functions are easily controlled from the four panel push buttons located below the display. APPLICATIONS · Pump inlet/outlet and compressors · Inert gas pressure measurement · Hydraulic/pneumatic systems · Energy and fluid management SPECIFICATIONS · Refrigeration equipment/ fluids/test stands · Industrial process control · Vacuum chambers · Lab and research · Irrigation GENERAL Input Power: 4 to 20mA Output Models Voltage Output Models Pressure Measurement Units Accuracy** Stability (1 yr) Over Range Protection Burst Pressure Pressure Cycles TEMPERATURE RANGES Media Operating (Ambient) Storage: 4 to 20mA and Voltage Output Models THERMAL LIMITS Compensated Range TC Zero TC Span 7.5 to 32 Vdc 15 to 32 Vdc See ordering table; consult factory for additional ranges psi, bar, kg/cm2, atm, in. of Hg, in. of H2O* (selectable) <± 0.5% BFSL*** ±0.25% of FS Typical 2x Rated Pressure 5x Rated Pressure or 5000 psi, whichever is less >100 Million -55 to 125 °C (-65 to 257 °F) -10 to 70 °C (15 to 158 °F) -40 to 65 °C (-40 to 150 °F) 0 to 55 °C (32 to 130 °F) <±1.5% of FS <±1.5% of FS Connection Update Rate 4 to 20mA and Voltage Output Models Housing Output: Analog Output Models WARRANTY Limited Warranty ¼" NPT Male 32 times per second NEMA 4, IP65, Polycarbonate 4 to 20 mA loop powered or 0-5/0-10 Vdc 1 year *Inches H2O units available on 250 psi range devices only **Accuracy includes non-linearity, hysteresis, and non-repeatability, measured at 25 °C (77 °F) ***Best fit straight line Note: Select a loop power supply and total loop resistance so that when the loop current is 20 mA, the gauge will have at least 7.5 Vdc at its terminals. 177 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 4 TO 20 mA OUTPUT VERSION Wiring Diagram connector locking screw Pressure Monitoring | PD Series VOLTAGE OUTPUT VERSION Wiring Diagram connector locking screw 15' lead (4.5m) red/black/white supply voltage 7.5 to 32 Vdc red/black control panel 4 to 20 mA input DIMENSIONAL DRAWING 3.1" (79mm) 1.8" (44mm) 1.3" (33mm) 2.2" (55mm) 0.7" (17mm) 5/8" ORDERING INFORMATION Pressure Range Material PD A 50 = 0 to 50 psig 100 = 0 to 100 psig 250 = 0 to 250 psig = 17 - 4SS Output M = 4 to 20 mA V = 0-5Vdc/0-10Vdc 15' lead (4.5m) red supply voltage 15 to 32 Vdc black control panel 4 to 20 mA input white 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 178 PX3 PAS PH PG EP2 EP3 PW PW2 PWR ACCESSORIES SELECTION GUIDE: PRESSURE MONITORING Product Description DRY PRESSURE AA05 Remote Wall Static Pickup Tube AA06 Static-04 Pick-up - 4" Duct Static Pickup Probe AA07 Static-08 Pick up - 8" Duct Static Pickup Probe AA18 Velocity Pitot Tube Kit - 8" Velocity Duct Probe AA19 Velocity Pitot Tube Kit - 12" Velocity Duct Probe AA20 Velocity Pitot Tube Kit - 18" Velocity Duct Probe AA43 Dust Cover AA45 Pneumatic Capacitor AA49 Triac Adaptor AA56 Wall Plate Remote Pickup WET PRESSURE AA11 Brass Snubber, 1/8" NPT AA12 Stainless Steel Snubber, 1/8" NPT AA13 Pigtail Steam Siphon AA14A Bypass Valve Assembly Bracket AA68 1/4" Ball Valve AA69 Brass Snubber, 1/4" NPT AA70 Stainless Steel Snubber, 1/4" NPT · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 179 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Pressure Monitoring | Accessories AA05 Remote Wall Static Pickup Tube AA06 Static-04 Pick-up - 4" Duct Static Pickup Probe AA07 Static-08 Pick up - 8" Duct Static Pickup Probe AA11/AA69 Brass Snubber, 1/8" NPT (AA11) Brass Snubber, 1/4" NPT (AA69) AA12/AA70 Stainless Steel Snubber, 1/8" NPT (AA12) Stainless Steel Snubber, 1/4" NPT (AA70) AA13 Pigtail Steam Siphon AA20 Velocity Pitot Tube Kit 18". AA43 Dust Cover AA14A Bypass Valve Assembly and Bracket AA18/AA19 Velocity Pitot Tube Kit 8" (AA18), Velocity Pitot Tube Kit 12" (AA19) AA45 Pneumatic Capacitor AA49 Triac Adapter AA56 Wall Plate Remote Pickup AA68 1/4" Ball Valve 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 180 TEMPERATURE MONITORING Veris offers a wide range of temperature sensing products for commercial building applications. Control and maintain a comfortable environment with our thermistor, RTD, and transmitter devices. We offer an array of mounting options for installation flexibility, including duct, wall, ceiling, pendant, and immersion. All devices carry the Veris reputation for accuracy and reliability, as well as an aesthetically pleasing housing, making them ideal for monitoring temperature in any setting. MODEL TW2 TW2xP TE & TP TC/TS TD/TF/TG/TDDA/TK TI TB/TRA TJ TA TO TZ DESCRIPTION Deluxe Wall Mount Temperature Sensors Deluxe Wall Mount Temperature Sensors, Protocol Communication Flush Mount Temperature Sensors Ceiling and Recessed Mount Temperature Sensors Duct Mount Temperature Sensors Immersion Temperature Sensors Specialty Temperature Sensors VAV Discharge Temperature Sensors Averaging Temperature Sensors Outdoor Temperature Sensors Manual and Automatic Freeze Stats with Relays PAGE 183 185 187 189 191 193 195 197 199 201 203 TEMPERATURE SENSOR SELECTION GUIDE FEATURES/ OPTIONS WALL MOUNT DUCT MOUNT CEILING MOUNT Analog Transmitter Output TW2, TEA page 183, 187 TDDA page 191 Resistive Output TW2 TD/TF/TG/TK TC/TS page 183 page 191 page 189 LCD Display* TW2L page 183 Touchscreen Display TW2T page 183 Averaging Sensor TW2 page 183 Protocol TW2xP Communication page 185 Relay Out Analog Display TZ page 203 *Requires AA04 Remote Display accessory, see page 205. OUTDOOR MOUNT TO page 201 FLUSH MOUNT TE/TP page 187 REMOTE TRA page 195 STRAPON IMMERSION VAV TB page 195 TI page 193 TJ page 197 181 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com MONITOR AND MAINTAIN A COMFORTABLE ENVIRONMENT Temperature Sensors and Monitors TW2 SERIES TEMPERATURE SENSORS » Modern aesthetic with color touchscreen (also available in LCD and non-display) » Field-replaceable and interchangeable » Flexible housing can also be used to measure Humidity, VOC, and CO2 TD SERIES DUCT TEMPERATURE SENSOR Cost-effective high-accuracy RTDs available with or without junction box Ideal for duct systems in industrial applications No calibration required TD SERIES TA SERIES AVERAGING TEMPERATURE SENSOR Flexible or fixed probe options cover all averaging applications with one line Ideal for duct temperature measurements TA SERIES TID SERIES PIPE/IMMERSION TEMPERATURE SENSOR Corrosion-resistant stainless steel probe, ideal for tanks, pipes, chillers Cost-effective high accuracy thermistors/RTDs TID SERIES 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 182 Temperature Monitoring | Analog Temperature Sensors TW2 SERIES Wall Mount Temperature Sensors Flexible Polarity insensitive, two-wire 4 to 20 mA or 3-wire 0-5/0-10 Vdc versions...flexible systems compatibity...save time in the field, stock fewer devices Calibration-free No calibration required Easy to install Large wiring terminals on baseplate and snap-on covers with security screw simplify installation and service TW2TAXx TW2LAXx TW2XAXx The TW2 Series of temperature sensors for living space is a versatile sensor platform for use with BAS controllers designed to accept 4 to 20mA, 0 to 5Vdc or 0 to 10Vdc outputs. TW2 Series sensors are available with three user interface options: touchscreen, LCD with three buttons and blank. APPLICATIONS · Controlling HVAC systems for improved comfort & energy savings · Museums, schools, printing shops, hospitals, data centers, & other locations that require temperature control · Facilitating compliance with ASHRAE standards for environmental control and indoor air quality SPECIFICATIONS OPERATING ENVIRONMENT Input Power Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz Analog Output Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V Operating Temperature Range 0 to 50 °C (32 to 122 °F) Operating Humidity Range 0 to 95% RH non-condensing Housing material High-impact ABS plastic Terminal Block Torque 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) TEMPERATURE TRANSMITTER OPTION Sensor Type Solid state, integrated circuit Accuracy ±0.2 °C (±0.4 °F) typical Resolution 0.1 °C (0.1 °F) Range 0 to 50 °C (32 to 122 °F) display models Touchscreen 61 mm (2.4 in), color, backlit, capacitive, 240x300 px Setpoint: 0-10Vdc. Temperature, humidity or fan speed selectable Timeout override: Display timeout* Lockout override: Touchscreen/button lockout* 52mm (2.05 in), segmented with 3 buttons Setpoint: 0-10Vdc. Temperature, LCD humidity or fan speed selectable Timeout override: Display timeout* Lockout override: Touchscreen/button lockout* SETPOINTS** Temperature Setpoint 0 to 10V output Scale: 10 to 35 °C (50 to 95 °F) / 0 to 50 °C (32 to 122 °F) Fan Speed Setpoint 0 to 10V output Off 0V, Low 3.3V, Med. 6.7V, High 10.0V OVERRIDE Override Button Display models feature a momentary-to-ground override button WIRING TERMINALS Terminal Blocks Screw terminals, 18-24 AWG Screw Terminal Torque 0.2 N-m (2.0 in-lbF) max. WARRANTY Limited Warranty 5 years COMPLIANCE INFORMATION Agency Approvals UL 916, European conformance CE: EN61000-6-2 EN61000-6-3 EN61000 Series - industrial immunity EN 61326-1 FCC Part 15 Class B, REACH, RoHS, RCM (Australia), ICES-003 (Canada) *DIP switch selectable. ** One setpoint type is selectable via DIP switch on display models only. DIMENSIONAL DRAWING 115 (4.5) 85 24 (3.3) (0.9) 183 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Temperature Monitoring | TW2 Series USER INTERFACE TYPES Touchscreen LCD with Buttons Blank ORDERING INFORMATION User Interface TW2 Output T = Color touchscreen L = 3-button LCD display X = None A = Analog output Example: TW2 T A X A Temperature X A = Transmitter only C = 1000 PT RTD D = 10K T2 thermistor H = 10K T3 thermistor K = 10K curve G/11K shunt M = 20K NTC thermistor N = 1.8K TAC thermistor TW2X/TW2T DISPLAY MODELS WITH TEMP TRANSMITTER Wiring Diagram OVERRIDE* SETPOINT OUT* 10 9 8 7 6 TEMP OUT COMMON POWER (+24) 5432 1 *TW2T models only. TW2L/TW2T DISPLAY MODELS WITH RTD/THERMISTOR Wiring Diagram OVERRIDE SETPOINT OUT RTD/THERMISTOR OUT RTD/THERMISTOR OUT COMMON POWER (+24) 10 9 8 7 6 5432 1 TW2X WITH RTD/THERMISTOR Wiring Diagram RTD/THERMISTOR OUT RTD/THERMISTOR OUT TW2L WITH TEMP TRANSMITTER Wiring Diagram TABLE OF STANDARD RTD & THERMISTOR VALUES Class Type Accuracy Temp. Response* Pt RTD 1000 Ohm ±0.3°C 0.00385 curve PTC THERMISTOR 10k Type 2 10k Type 3 20k ±1.0°C ±0.2°C Consult -50/150°C 0/70°C Factory NTC NTC NTC STANDARD RTD AND THERMISTOR VALUES (Ohms ) °C °F 1000 Ohm 10k Type 2 10k Type 3 20k NTC -50 -58 803.06 692,700 454,910 1,267,600 -40 -40 842.71 344,700 245,089 643,800 -30 -22 882.22 180,100 137,307 342,000 -20 -4 921.60 98,320 79,729 189,080 -10 14 960.86 55,790 47,843 108,380 0 32 1,000.00 32,770 29,588 64,160 10 50 1,039.03 19,930 18,813 39,440 20 68 1,077.94 12,500 12,272 24,920 25 77 1,097.35 10,000 10,000 20,000 30 86 1,116.73 8,055 8,195 16,144 40 104 1,155.41 5,323 5,593 10,696 50 122 1,193.97 3,599 3,894 7,234 60 140 1,232.42 2,486 2,763 4,992 70 158 1,270.75 1,753 1,994 3,512 80 176 1,308.97 1,258 1,462 2,516 90 194 1,347.07 919 1,088 1,833 100 212 1,385.06 682 821 1,356 110 230 1,422.93 513 628 1,016 120 248 1,460.68 392 486 770 130 266 1,498.32 303 380 591 Sensor Codes C D H M TEMP OUT OVERRIDE SETPOINT OUT COMMON POWER (+24) 5432 1 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 184 Temperature Monitoring | Protocol Temperature Sensors TW2 PROTOCOL SERIES Wall Mount Temperature Sensors TW2TPXx TW2LPXx TW2XPXx The TW2 Protocol Series of temperature sensors for living space is a versatile sensor platform for use with BAS controllers designed to accept BACnet or Modbus outputs. TW2 Protocol Series sensors are available with three user interface options: touchscreen, LCD with three buttons and blank. SPECIFICATIONS OPERATING ENVIRONMENT Input Power Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz Protocol Output BACnet or Modbus via RS-485, selectable Operating Temperature Range 0 to 50 °C (32 to 122 °F) Operating Humidity Range 0 to 95% RH non-condensing Housing material High-impact ABS plastic Terminal Block Torque 0.5 to 0.6 N-m (0.37 to 0.44 in-lbf ) TEMPERATURE TRANSMITTER Sensor Type Solid state, integrated circuit Accuracy ±0.2 °C (±0.4 °F) typical Resolution 0.1 °C (0.1 °F) Range 0 to 50 °C (32 to 122 °F) DISPLAY MODELS Touchscreen 61 mm (2.4 in), color, backlit, capacitive, 240x300 px Setpoint: Temperature or fan speed selectable Timeout override: Display timeout Lockout override: Touchscreen/button lockout 52mm (2.05 in), segmented with 3 buttons Setpoint: Temperature or fan speed select- LCD able Timeout override: Display timeout Lockout override: Touchscreen/button lockout SETPOINTS Temperature Setpoint Scale: 10 to 35 °C (50 to 95 °F) / 0 to 50 °C (32 to 122 °F) Fan Speed Setpoint Off, Low, Medium, High OVERRIDE Override Button Display models feature a momentary override button BACnet & Modbus Embedded BACnet and Modbus communication protocols...easy systems integration Multiple baud rates Configurable baud rates... ensures network compatibility Network configuration Eliminates the cost of home run wiring and analog inputs required by traditional sensors Displays have setpoint Selectable temperature or fan speed setpoint...easy to use APPLICATIONS · Controlling HVAC systems for improved comfort & energy savings · Museums, schools, printing shops, hospitals, data centers, & other locations that require temperature control · Facilitating compliance with ASHRAE standards for environmental control and indoor air quality WIRING TERMINALS Terminal Blocks Screw Terminal Torque WARRANTY Limited Warranty COMPLIANCE INFORMATION Agency Approvals Screw terminals, 18-24 AWG 0.2 N-m (2.0 in-lbF) max. 5 years UL 916, European conformance CE: EN61000-6-2 EN61000-6-3 EN61000 Series - industrial immunity EN 61326-1 FCC Part 15 Class B, REACH, RoHS, RCM (Australia), ICES-003 (Canada) 185 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING Temperature Monitoring | TW2 Protocol Series USER INTERFACE TYPES 115 (4.5) 85 24 (3.3) (0.9) WIRING DIAGRAM Touchscreen LCD with Buttons RS-485 (+) RS-485 (-) GROUND POWER (+24) 5432 1 ORDERING INFORMATION MODEL TW2TPXA TW2LPXA TW2XPXA USER INTERFACE Touchscreen LCD / 3 Buttons Blank SETPOINT X X OVERRIDE X X TEMPERATURE SENSOR Temperature Transmitter Temperature Transmitter Temperature Transmitter Blank 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 186 Temperature Monitoring | Flush Mount Temperature Sensors TE & TP SERIES Durable Devices for Temperature Monitoring Moisture resistant Potted sensor element (TP Series) Flexibile Available with RTD and thermistors. TE Series also available with transmitter and linitemp outputs. Durable Stainless steel construction (TP Series) Simple maintenance Easy to clean Easy installation TE Mounts to standard duplex wall mount box SPECIFICATIONS TE Series Wiring TP TE Series wall mounted temperature sensors feature a discreet appearance combined with high accuracy and reliability. These devices are aesthetically pleasing in any interior environment. Flexible mounting options include flush and single-gang for ease of installation. TP Series flush mounted temperature sensors are designed to monitor the temperature of the air in areas where sensor durability and security are needed. They are ideal for spaces where moisture and water vapor are concerns. The back of the TP is insulated to reduce interior wall temperature influence. The TP is for indoor use only, and it is warranted for a period of five years. SPECIFICATIONS TP Series Wiring Housing Mounting Location Operating Temperature WARRANTY Limited Warranty AGENCY APPROVALS 22 AWG; 2-wire: RTD/Thermistor Brushed 430 stainless steel Not suitable for wet locations. For indoor use only. -25 to 105 °C (-13 to 221 °F)* 5 years *Room temperature offset documented on each unit. Housing Operating Temp LINITEMP OPTION Input Power Output Operating Temp Calibration Offset Offset over Temp WARRANTY Limited Warranty SPECIFICATIONS TEA Series Input Power RANGES TEA Model Analog Output TEA 4 to 20 mA model Transmitter Type Transmitter Accuracy WARRANTY Limited Warranty AGENCY APPROVALS 22 AWG; 2-wire: RTD Thermistor, 4 to 20 mA; 3-wire: voltage output models Black or white ABS plastic -25 to 105 °C (-13 to 221 °F) Class 2; 5 to 30 Vdc 10 mV/°C -25 to 105 °C (-13 to 221 °F) 1.5 °C (2.7 °F) typ.; 2.5 °C (4.5 °F) max. at 25 °C (77 °F)* 1.8 °C (3.24 °F) typical; 3.0°C (5.4 °F) max. over 0 to 70 °C (32 to 158 °F) range; 2.0 °C (3.6 °F) typical, 3.5 °C (6.3 °F) max. over -25 to 105 °C (-13 to 221 °F) range 5 years 4 to 20 mA mode; loop powered Class 2; 24 Vdc only; 0-10 V, 3-wire, observe polarity; 12-30 Vdc; 0-5 V, 3-wire, observe polarity; 24 Vac, 50/60 Hz, 12-30 Vdc 10 to 35 °C (50 to 95 °F) 2-wire, not polarity sensitive (clipped & capped) Solid-state, integrated circuit ±0.5 °C (±.9 °F) typical 5 years *Room temperature offset documented on each unit. Note: RTD/Thermistors in wall packages are not compensated for internal heating of product. 187 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com TP Dimensional Drawing 2.8" (72 mm) 2x Ø 0.175" (5 mm) 4.5" (115 mm) 3.3" (84 mm) Temperature Monitoring | TE & TP Series TE/TEA Dimensional Drawing 0.25" (6 mm) 3.2" (82 mm) 4.5" (115 mm) 1.4" (36 mm) TP Wiring Diagram DIGITAL CONTROL Thermistor/RTD Back of TP steel plate 2.8" (72 mm) 0.5" (13 mm) ORDERING INFORMATION Sensor Type TP B = 100R Platinum, RTD 0 = None C = 1k Platinum, RTD 2 = 3-point NIST calibration D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor H = 10k T3, Thermistor I = 1k Balco (Nickel-iron) RTD Example: J = 10k Dale, Thermistor K = 10k w/11k shunt,Thermistor TP W 2 M = 20k NTC, Thermistor N = 1800 ohm, Thermistor T = 100k, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Output TEA US or EU S Housing Color Example: TEA J S M= 4 to 20 mA V = 0-10 Vdc J = 0-5 Vdc = Standard None = Cloud White B = Black Sensor Type TE Setpoint/ Override Cal Certificate Housing Color B= 100R platinum, RTD 0 = None 0 = None None = Cloud white C= 1k platinum, RTD 1 = Override* 1 = 1-point B = Black D= 10k T2, Thermistor 2 = 1k Setpoint cal validation** E= 2.2k, Thermistor 3 = 10k Setpoint 2 = 2-point F= 3k, Thermistor 4 = 1k Setpoint cal validation** G= 10k CPC, Thermistor with override* H= 10k T3, Thermistor 5 = 10k Setpoint I= 1k Balco (Nickel-iron) RTD with override* J= 10k Dale, Thermistor K= 10k w/11k shunt, Thermistor M= 20k NTC, Thermistor Example: N= 1800 ohm, Thermistor P= 10mV/°C, Linitemp TE D 5 2 R= 10k US, Thermistor S= 10k 3A221, Thermistor T= 100k, Thermistor U= 20k "D", Thermistor *Pushbutton override short circuits RTD/thermistor output ** Not available with W and Y high-accuracy thermistors. W= 10k T2 high accuracy, Thermistor Y= 10k T3 high accuracy, Thermistor 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 205 188 Temperature Monitoring | Ceiling & Recessed Mount Temperature Sensors TC & TS SERIES Low Profile Housing with a Variety of RTD and Thermisor Options TC Ceiling mount Ceiling mount probe for more accurate readings...ideal for open office environments Recessed sensor Recessed press-fit sensor virtually "disappears"...great for museums and galleries APPLICATIONS · Hospitals and operating rooms, pharmaceutical labs · Clean rooms · Food processing plants · Environmental testing facilities and other institutional applications TS TC and TS sensors are ceiling-mounted in an unobtrusive housing. The easy-to-install units are ideal for office environments, as well as museums, galleries, or any other open indoor setting. These sensors are highly accurate, reliable, and come with a five-year warranty. Choose from a variety of RTD or thermistor sensor types to suit any need. SPECIFICATIONS TC & TS Series Wiring 22 AWG; 2-wire: RTD/Thermistor; 3-wire: Linitemp Housing White ABS plastic (black available for TS only) Operating Temp -25 to 105 °C (-13 to 221 °F)* WARRANTY Limited Warranty 5 years * For RTD and thermistor accuracies and ranges, see the thermistor table on page 190. **Room temperature offset documented on each unit. 189 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Temperature Monitoring | TC & TS Series TC Dimensional Drawing 2" (51 mm) 1.4" (36 mm) TS Dimensional Drawing 0.3" (8 mm) 2.1" (52 mm) 2" (51 mm) 1.4" (36 mm) 0.3" (8 mm) 2.1" (52 mm) 1.4" (35 mm) L 1.4" (35 mm) ORDERING INFORMATION Probe Length Sensor Type Calibration Certificate TC B = 4" (102mm) C = 6" (152mm) D = 8" (203mm) E = 12" (305mm) F = 18" (457mm) G = 24" (610mm) B = 100R platinum, RTD C = 1k platinum, RT D = 10k T2, Thermistor 0 = None 1 = 1-point cal validation* 2 = 2-point cal validation* E = 2.2k, Thermistor F = 3k, Thermistor G = 10k CPC, Thermistor H = 10k T3, Thermistor J = 10k Dale, Thermistor K = 10k w/11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm, Thermistor R = 10k US, Thermistor S = 10k 3A221, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor * Not available with W and Y high-accuracy thermistors. Example: TC D D 2 Sensor Type Calibration Certificate Housing Color TS B = 100R platinum, RTD C = 1k platinum, RTD D = 10k T2, Thermistor 0 = None 1 = 1-point cal validation* 2 = 2-point cal validation* E = 2.2k, Thermistor F = 3k, Thermistor G = 10k CPC, Thermistor H = 10k T3, Thermistor I = 1k Balco (Nickel-iron) RTD J = 10k Dale, Thermistor Example: K = 10k w/11k shunt, Thermistor M = 20k NTC, Thermistor TS D N = 1800 ohm, Thermistor R = 10k US, Thermistor S = 10k 3A221, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor None = Cloud White B = Black 2 * Not available with W and Y high-accuracy thermistors. TABLE OF STANDARD RTD AND THERMISTOR VALUES Class Pt RTD Balco RTD THERMISTOR Type 100 Ohm 1000 Ohm 1000 Ohm 2.2k 3k 10k Type 2 10k Type 3 10k Dale 10k 3A221 10k "G" US Accuracy ±0.3°C ±0.3°C ±1% @70°C ±0.2°C ±0.2°C ±1.0°C ±0.2°C ±0.2°C ±1.1°C ±0.2°C 0.00385 0.00385 curve curve 0/70°C 0/70°C -50/150°C 0/70°C -20/70°C 0/70°C 0/70°C Temp. Response* PTC PTC PTC NTC NTC NTC NTC NTC NTC NTC *PTC: Positive Temperature Coefficient *NTC: Negative Temperature Coefficient STANDARD RTD AND THERMISTOR VALUES (Ohms ) °C °F 100 Ohm 1000 Ohm 1000 Ohm 2.2k 3k 10k Type 2 10k Type 3 10k Dale 10k 3A221 10k "G" US -50 -58 80.306 803.06 740.46 154,464 205,800 692,700 454,910 672,300 - 441,200 -40 -40 84.271 842.71 773.99 77,081 102,690 344,700 245,089 337,200 333,562 239,700 -30 -22 88.222 882.22 806.02 40,330 53,730 180,100 137,307 177,200 176,081 135,300 -20 -4 92.160 921.60 841.00 22,032 29,346 98,320 79,729 97,130 96,807 78,910 -10 14 96.086 960.86 877.46 12,519 16,674 55,790 47,843 55,340 55,252 47,540 0 32 100.000 1,000.00 913.66 7,373 9,822 32,770 29,588 32,660 32,639 29,490 10 50 103.903 1,039.03 952.25 4,487 5,976 19,930 18,813 19,900 19,901 18,780 20 68 107.794 1,077.94 991.82 2,814 3,750 12,500 12,272 12,490 12,493 12,260 25 77 109.735 1,097.35 1,013.50 2,252 3,000 10,000 10,000 10,000 10,000 10,000 30 86 111.673 1,116.73 1,035.18 1,814 2,417 8,055 8,195 8,056 8,055 8,194 40 104 115.541 1,155.41 1,077.68 1,199 1,598 5,323 5,593 5,326 5,324 5,592 50 122 119.397 1,193.97 1,120.52 811.5 1,081 3,599 3,894 3,602 3,600 3,893 60 140 123.242 1,232.42 1,166.13 561.0 747 2,486 2,763 2,489 2,486 2,760 70 158 127.075 1,270.75 1,210.75 395.5 527 1,753 1,994 1,753 1,751 1,990 80 176 130.897 1,308.97 1,254.55 284.0 378 1,258 1,462 1,258 1,255 1,458 90 194 134.707 1,347.07 1,301.17 207.4 - 919 1,088 917 915 1,084 100 212 138.506 1,385.06 1,348.38 153.8 - 682 821 679 678 816.8 110 230 142.293 1,422.93 1,397.13 115.8 - 513 628 511 509 623.6 120 248 146.068 1,460.68 1,447.44 88.3 - 392 486 389 388 481.8 130 266 149.832 1,498.32 1,496.28 68.3 - 303 380 301 299 376.4 Sensor Codes B C I E F D H J S R 20k Consult Factory NTC 20k NTC 1,267,600 643,800 342,000 189,080 108,380 64,160 39,440 24,920 20,000 16,144 10,696 7,234 4,992 3,512 2,516 1,833 1,356 1,016 770 591 M 20k "D" Consult Factory 100k Consult Factory NTC NTC 20k "D" - 803,200 412,800 220,600 122,400 70,200 41,600 25,340 20,000 15,884 10,210 6,718 4,518 3,100 2,168 1,542 1,134 816 606 456 100k - 3,366,000 1,770,000 971,200 553,400 326,600 199,000 124,900 100,000 80,580 53,260 36,020 24,880 17,510 12,560 9,164 6,792 5,108 3,894 3,006 U T 10k Type 2 10k Type 3 ±0.1°C 20/70°C ±0.1°C ±0.2°C 0/20°C 0/70°C NTC NTC High Accuracy 10k Type 2 692,700 344,700 180,100 98,320 55,790 32,770 19,930 12,500 10,000 8,055 5,323 3,599 2,486 1,753 1,258 919 682 513 392 303 W 10k Type 3 454,910 245,089 137,307 79,729 47,843 29,588 18,813 12,272 10,000 8,195 5,593 3,894 2,763 1,994 1,462 1,088 821 628 486 380 Y 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 205 190 Temperature Monitoring | Duct Mount Temperature Sensors T SERIES Sensor Housed in Probe, Protects Against Corrosion TDDA TF Cost effective Cost-effective, high accuracy thermistors or RTDs available with or without a junction box Durable Corrosion resistant stainless steel probe design No calibration No calibration required APPLICATIONS · Duct systems · Industrial TG TD TK Duct mount temperature sensors from Veris are pre-calibrated and housed in sturdy stainless steel probes. The devices are easy to install, durable, and highly accurate. SPECIFICATIONS Wiring 22 AWG; 2-wire: RTD/Thermistor, 4 to 20 mA Mounting Location Not suitable for wet locations. For indoor use only. TEMPERATURE TRANSMITTER OPTION Input Power 4 to 20 mA models: Loop powered Class 2, 12 to 30 Vdc only, 30 mA max; 0-5/0-10 V models: Class 2, 12 to 30 Vdc/24 Vac, 50/60 Hz, 15 mA max Temp. Output 2-wire, loop powered 4 to 20 mA 3-wire, 0-5V/0-10Vdc Sensor Type Solid-state, integrated circuit Transmitter Accuracy ±0.5 °C (±0.9 °F) typical* Ranges Selectable 0 to 50 °C (32 to 122 °F) or -40 to 50 °C (-40 to 122 °F) RESISTIVE OPTION Operating Temp -25 to 105 °C (-13 to 221 °F) WARRANTY Limited Warranty 5 years AGENCY APPROVALS *Room temperature offset documented on each unit. ORDERING INFORMATION RTD/Thermistor Models Enclosure T Immersion Probe Length "L" Sensor Type Output RØ Calibration Certificate D = Duct K = Probe only (no mounting hardware) F = Duct with mounting box G = Duct with water resistant housing B = 4" (102mm)* C = 6" (152mm) D = 8" (203mm) E = 12"(305mm)** F = 18"(457mm)** G = 24"(610mm)** K = 36"(914mm)** * TK model is 4 1/2" (115 mm) ** Not available with TK model Example: TD B D R0 2 B = 100R platinum, RTD C = 1k platinum, RTD = Resistive Output D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor H = 10k T3, Thermistor I = 1k Balco (Nickel-iron) RTD J = 10k Dale, Thermistor K = 10k w/11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm, Thermistor T = 100k, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor 0 = None 2 = 3-point NIST calibration Transmitter Models Output TDDA M = 4 to 20mA V = 5/10 V Range 1 = -40 to 50 °C (-40 to 122 °F) 2 = 0 to 50 °C (32 to 122 °F) Cal Certificate Example: TDDA V 2 0 0 = None 2 = 3-point NIST certification ACCESSORIES AA64 Klipet Mounting Clip 191 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Temperature Monitoring | T Series TD Dimensional Drawing 1.5" (38 mm) 2" (51 mm) 1.1" (28 mm) TF Dimensional Drawing 4.20" (106.68 mm) 3.88" (98.60 mm) TK Dimensional Drawing 0.25" (6 mm) L TDDA Dimensional Drawing 0.7" (18 mm) 2.9" 0.25"Dia. (74 mm) (6 mm) Foam Gasket L 2.5" x 2.5" (64 mm x 64 mm) 4.6" (117 mm) Available in 4", 6", 12"and 18" probe lengths 2.0" (51 mm) 8.5" (216 mm) TG Dimensional Drawing 0.7" (18 mm) 1.78" (45.18mm) 2.9" (74 mm) 4.6" (117 mm) Foam Gasket 2.5" x 2.5" (64 mm x 64 mm) L 2.0" (51 mm) 0.5" Dia. (13 mm.) 0.25"Dia. (6.3 mm) STANDARD RTD AND THERMISTOR VALUES Class Type Accuracy Temp. Response* Pt RTD 100 Ohm 1000 Ohm ±0.3°C ±0.3°C 0.00385 0.00385 curve curve PTC PTC Balco RTD 1000 Ohm ±1% @70°C PTC 2.2k ±0.2°C 0/70°C NTC 3k ±0.2°C 0/70°C NTC 10k Type 2 ±1.0°C -50/150°C NTC THERMISTOR 10k Type 3 10k Dale 20k ±0.2°C ±0.2°C Consult 0/70°C -20/70°C Factory NTC NTC NTC 100k 10k Type 2 10k Type 3 Consult ±0.1°C 20/70°C ±0.1°C Factory ±0.2°C 0/20°C 0/70°C NTC NTC NTC High Accuracy °C °F -50 -58 -40 -40 -30 -22 -20 -4 -10 14 0 32 10 50 20 68 25 77 30 86 40 104 50 122 60 140 70 158 80 176 90 194 100 212 110 230 120 248 130 266 Sensor Codes Z202030-0U 100 Ohm 80.306 84.271 88.222 92.160 96.086 100.000 103.903 107.794 109.735 111.673 115.541 119.397 123.242 127.075 130.897 134.707 138.506 142.293 146.068 149.832 B 1000 Ohm 803.06 842.71 882.22 921.60 960.86 1,000.00 1,039.03 1,077.94 1,097.35 1,116.73 1,155.41 1,193.97 1,232.42 1,270.75 1,308.97 1,347.07 1,385.06 1,422.93 1,460.68 1,498.32 C STANDARD RTD AND THERMISTOR VALUES (Ohms ) 1000 Ohm 2.2k 3k 10k Type 2 10k Type 3 10k Dale 20k NTC 100k 740.46 154,464 205,800 692,700 454,910 672,300 1,267,600 - 773.99 77,081 102,690 344,700 245,089 337,200 643,800 3,366,000 806.02 40,330 53,730 180,100 137,307 177,200 342,000 1,770,000 841.00 22,032 29,346 98,320 79,729 97,130 189,080 971,200 877.46 12,519 16,674 55,790 47,843 55,340 108,380 553,400 913.66 7,373 9,822 32,770 29,588 32,660 64,160 326,600 952.25 4,487 5,976 19,930 18,813 19,900 39,440 199,000 991.82 2,814 3,750 12,500 12,272 12,490 24,920 124,900 1,013.50 2,252 3,000 10,000 10,000 10,000 20,000 100,000 1,035.18 1,814 2,417 8,055 8,195 8,056 16,144 80,580 1,077.68 1,199 1,598 5,323 5,593 5,326 10,696 53,260 1,120.52 811.5 1,081 3,599 3,894 3,602 7,234 36,020 1,166.13 561.0 747 2,486 2,763 2,489 4,992 24,880 1,210.75 395.5 527 1,753 1,994 1,753 3,512 17,510 1,254.55 284.0 378 1,258 1,462 1,258 2,516 12,560 1,301.17 207.4 - 919 1,088 917 1,833 9,164 1,348.38 153.8 - 682 821 679 1,356 6,792 1,397.13 115.8 - 513 628 511 1,016 5,108 1,447.44 88.3 - 392 486 389 770 3,894 1,496.28 68.3 - 303 380 301 591 3,006 I E F D H J M T 10k Type 2 692,700 344,700 180,100 98,320 55,790 32,770 19,930 12,500 10,000 8,055 5,323 3,599 2,486 1,753 1,258 919 682 513 392 303 W 10k Type 3 454,910 245,089 137,307 79,729 47,843 29,588 18,813 12,272 10,000 8,195 5,593 3,894 2,763 1,994 1,462 1,088 821 628 486 380 Y 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 205 192 Temperature Monitoring | Immersion Temperature Sensors TI SERIES Corrosion Resistant Stainless Steel Probe Cost effective Cost-effective, high-accuracy thermistors/RTDs Easy selection 1/2" NPT threads standard Durable Easy servicing Corrosion resistant stainless steel Thermowells available probe design TIW Variety of TID enclosures Duct mount, service entry body, threaded, and water resistant to fit your application TIG TIH These immersion probe type temperature sensors are both highly accurate and cost effective. Installation could not be easier. The sensor is encased in a corrosion-resistant stainless steel probe for durability, with a choice of service entry body, indoor junction box, or threaded enclosures. A variety of RTD or thermistor sensor options and probe lengths are available for maximum application versatility. APPLICATIONS · Tanks · Pipes TIG Dimensional Drawing SPECIFICATIONS Wiring 22 AWG; 2-wire: RTD/Thermistor Probe Stainless steel Test Pressure 200 psi Operating Temp -25 to 105 °C (-13 to 221 °F)* WARRANTY Limited Warranty 5 years *Room temperature offset documented on each unit. · Chillers 1.5" (38 mm) 0.25"Dia. (6 mm) 1/2" NPT Standard L TIH Dimensional Drawing Immersion Probes 1/2" NPT Standard Thermowells L Overall: "L" + 2" (51 mm) 1/2" NPT Standard L Overall: "L" + 1.75" (45mm) 0.25" dia. (6 mm) 0.375" dia. (10 mm) 193 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Temperature Monitoring | TI Series TID Dimensional Drawing 4" (102 mm) 2.2" (56 mm) TIW Dimensional Drawing 4.5" (114 mm) 0.5" nom. (13 mm) 1/2" NPT Standard L 2.8" (71 mm) 1/2" NPT Standard L 1.5" (38 mm) 0.25" dia" (6 mm) ORDERING INFORMATION Enclosure TI Immersion Probe Length "L" Thermowell Sensor Type Options Calibration Certificate Threads D = Duct G = Service Entry Body H = Threaded NPT Only W = Water Resistant Housing A = 3 1/2" (89 mm) B = 5" (127 mm) C = 7" (178 mm) E = 13" (330 mm) 0 = None 1 = Add Thermowell B = 100R platinum, RTD C = 1k platinum, RTD D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor H = 10k T3, Thermistor I = 1k Balco (Nickel-iron) RTD J = 10k Dale, Thermistor K = 10k w/11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm, Thermistor T = 100k, Thermistor 0 = None 2 = 3-point NIST calibration W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Blank = NPT 0.25" dia" (6 mm) Example: TI W D 0 H 0 Thermowell Sizing Probe Length Thermowell Length A (3 1/2") (89 mm) 2 1/2" (64 mm) B (5") (127 mm) 4" (102 mm) C (7") (178 mm) 6" (152 mm) E (13") (330 mm) 12" (305 mm) Thermowells can be ordered as an option on all TI Series sensors. They can also be ordered separately using the table below. AA24 2-1/2" (64 mm) thermowell AA22 4" (102 mm) thermowell AA25 6" (152 mm) thermowell STANDARD RTD AND THERMISTOR VALUES Class Type Accuracy Temp. Response* Pt RTD 100 Ohm 1000 Ohm ±0.3°C ±0.3°C 0.00385 0.00385 curve curve PTC PTC Balco RTD 1000 Ohm ±1% @70°C PTC 2.2k ±0.2°C 0/70°C NTC 3k ±0.2°C 0/70°C NTC 10k Type 2 ±1.0°C -50/150°C NTC THERMISTOR 10k Type 3 10k Dale 20k ±0.2°C ±0.2°C Consult 0/70°C -20/70°C Factory NTC NTC NTC 100k 10k Type 2 10k Type 3 Consult ±0.1°C 20/70°C ±0.1°C Factory ±0.2°C 0/20°C 0/70°C NTC NTC NTC High Accuracy °C °F -50 -58 -40 -40 -30 -22 -20 -4 -10 14 0 32 10 50 20 68 25 77 30 86 40 104 50 122 60 140 70 158 80 176 90 194 100 212 110 230 120 248 130 266 Sensor Codes Z202030-0U 100 Ohm 80.306 84.271 88.222 92.160 96.086 100.000 103.903 107.794 109.735 111.673 115.541 119.397 123.242 127.075 130.897 134.707 138.506 142.293 146.068 149.832 B 1000 Ohm 803.06 842.71 882.22 921.60 960.86 1,000.00 1,039.03 1,077.94 1,097.35 1,116.73 1,155.41 1,193.97 1,232.42 1,270.75 1,308.97 1,347.07 1,385.06 1,422.93 1,460.68 1,498.32 C STANDARD RTD AND THERMISTOR VALUES (Ohms ) 1000 Ohm 2.2k 3k 10k Type 2 10k Type 3 10k Dale 20k NTC 100k 740.46 154,464 205,800 692,700 454,910 672,300 1,267,600 - 773.99 77,081 102,690 344,700 245,089 337,200 643,800 3,366,000 806.02 40,330 53,730 180,100 137,307 177,200 342,000 1,770,000 841.00 22,032 29,346 98,320 79,729 97,130 189,080 971,200 877.46 12,519 16,674 55,790 47,843 55,340 108,380 553,400 913.66 7,373 9,822 32,770 29,588 32,660 64,160 326,600 952.25 4,487 5,976 19,930 18,813 19,900 39,440 199,000 991.82 2,814 3,750 12,500 12,272 12,490 24,920 124,900 1,013.50 2,252 3,000 10,000 10,000 10,000 20,000 100,000 1,035.18 1,814 2,417 8,055 8,195 8,056 16,144 80,580 1,077.68 1,199 1,598 5,323 5,593 5,326 10,696 53,260 1,120.52 811.5 1,081 3,599 3,894 3,602 7,234 36,020 1,166.13 561.0 747 2,486 2,763 2,489 4,992 24,880 1,210.75 395.5 527 1,753 1,994 1,753 3,512 17,510 1,254.55 284.0 378 1,258 1,462 1,258 2,516 12,560 1,301.17 207.4 - 919 1,088 917 1,833 9,164 1,348.38 153.8 - 682 821 679 1,356 6,792 1,397.13 115.8 - 513 628 511 1,016 5,108 1,447.44 88.3 - 392 486 389 770 3,894 1,496.28 68.3 - 303 380 301 591 3,006 I E F D H J M T 10k Type 2 692,700 344,700 180,100 98,320 55,790 32,770 19,930 12,500 10,000 8,055 5,323 3,599 2,486 1,753 1,258 919 682 513 392 303 W 10k Type 3 454,910 245,089 137,307 79,729 47,843 29,588 18,813 12,272 10,000 8,195 5,593 3,894 2,763 1,994 1,462 1,088 821 628 486 380 Y ACCESSORIES P. 205 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 194 Temperature Monitoring | Specialty Temperature Sensors TB & TRA SERIES High Accuracy Specialty Sensors TB TRA Secondary measurement Secondary measurement of water temperature...ideal for retrofit applications (TB) Long sensor life Durable copper sensing probe (TRA) Easy installation Pipe clamps allow for easy installation on pipes up to 12" in diameter (TB) Multiple cable lengths Multiple cable lengths for application flexibility (TRA) The TB strap-on sensor uses a clamp to secure the unit to a pipe and a copper sensing plate for fast temperature response. The TB is perfect for secondary measurement of water temperature typical in retrofit applications. It includes a steel mounting box for wire termination and easy conduit connection. The TRA Series copper remote probe is designed for high accuracy in remote temperature sensing applications. The TRA can be used in numerous refrigeration applications or can be mounted on pipes for chilled or heated water temperature sensing. It is easily installed and includes a durable copper sensing probe with a two-wire cable. Multiple cable lengths are available for added flexibility. TB Dimensional Drawing 4" (102 mm) SPECIFICATIONS TB & TRA Series Wiring 22 AWG; 2-wire: RTD/Thermistor Operating Temperature TB TRA -25 to 105 °C (-13 to 221 °F)* Probe: -25 to 105 °C (-13 to 221 °F), Wiring: -20 to 80 °C (-4 to 176 °F) WARRANTY Limited Warranty 5 years *Room temperature offset documented on each unit. TRA Dimensional Drawing 1.10"(27.94 mm) strap ts pipe diameters up to 12" 2.9" (74 mm) L (cable length) .31" (7.87 mm) Strip Length Ø.38"(9.53 mm) Note: The TRA Series is optimized for strapping to pipe. 195 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Temperature Monitoring | TB & TRA Series ORDERING INFORMATION Strap-on Bracket Diameter TB Sensor Type Calibration Certificate A = 2" to 5" (5.1 to 12.7 cm) max. E = 2" to 12" (5.1 to 30.5 cm) max. B = 100R platinum, RTD 0 = None C = 1k platinum, RTD 2 = 3-point NIST calibration D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor H = 10k T3, Thermistor I = 1k Balco (Nickel-iron) RTD J = 10k Dale, Thermistor K = 10k w/11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm, Thermistor T = 100k, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Remote Probe Sensor Type TRA Calibration Certificate Cable Length B = 100R platinum, RTD 0 = None None = 3 ft (0.9 m) C = 1k platinum, RTD 2 = 3-point NIST calibration A = 6 ft (1.8 m)*** D = 10k T2, Thermistor B = 10 ft (3.1 m)* E = 2.2k, Thermistor C = 20 ft (6.1 m)** F = 3k, Thermistor D = 25 ft (7.6 m)** H = 10k T3, Thermistor E = 50 ft (15 m)** I = 1k Balco (Nickel-iron) RTD F = 100 ft (30 m)** J = 10k Dale, Thermistor K = 10k w/11k shunt, Thermistor M = 20k NTC, Thermistor Examples: N = 1800 ohm, Thermistor T = 100k, Thermistor TB A C 2 W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor TRA F 2 *Not available for sensor types B, C & P. **Not available for sensor types B, C, E, F, N & P. ***Not available for sensor types B & P. STANDARD RTD AND THERMISTOR VALUES Class Type Accuracy Temp. Response* Pt RTD 100 Ohm 1000 Ohm ±0.3°C ±0.3°C 0.00385 0.00385 curve curve PTC PTC Balco RTD 1000 Ohm ±1% @70°C PTC 2.2k ±0.2°C 0/70°C NTC 3k ±0.2°C 0/70°C NTC 10k Type 2 ±1.0°C -50/150°C NTC THERMISTOR 10k Type 3 10k Dale 20k ±0.2°C ±0.2°C Consult 0/70°C -20/70°C Factory NTC NTC NTC 100k 10k Type 2 10k Type 3 Consult ±0.1°C 20/70°C ±0.1°C Factory ±0.2°C 0/20°C 0/70°C NTC NTC NTC High Accuracy °C °F -50 -58 -40 -40 -30 -22 -20 -4 -10 14 0 32 10 50 20 68 25 77 30 86 40 104 50 122 60 140 70 158 80 176 90 194 100 212 110 230 120 248 130 266 Sensor Codes Z202030-0U 100 Ohm 80.306 84.271 88.222 92.160 96.086 100.000 103.903 107.794 109.735 111.673 115.541 119.397 123.242 127.075 130.897 134.707 138.506 142.293 146.068 149.832 B 1000 Ohm 803.06 842.71 882.22 921.60 960.86 1,000.00 1,039.03 1,077.94 1,097.35 1,116.73 1,155.41 1,193.97 1,232.42 1,270.75 1,308.97 1,347.07 1,385.06 1,422.93 1,460.68 1,498.32 C STANDARD RTD AND THERMISTOR VALUES (Ohms ) 1000 Ohm 2.2k 3k 10k Type 2 10k Type 3 10k Dale 20k NTC 100k 740.46 154,464 205,800 692,700 454,910 672,300 1,267,600 - 773.99 77,081 102,690 344,700 245,089 337,200 643,800 3,366,000 806.02 40,330 53,730 180,100 137,307 177,200 342,000 1,770,000 841.00 22,032 29,346 98,320 79,729 97,130 189,080 971,200 877.46 12,519 16,674 55,790 47,843 55,340 108,380 553,400 913.66 7,373 9,822 32,770 29,588 32,660 64,160 326,600 952.25 4,487 5,976 19,930 18,813 19,900 39,440 199,000 991.82 2,814 3,750 12,500 12,272 12,490 24,920 124,900 1,013.50 2,252 3,000 10,000 10,000 10,000 20,000 100,000 1,035.18 1,814 2,417 8,055 8,195 8,056 16,144 80,580 1,077.68 1,199 1,598 5,323 5,593 5,326 10,696 53,260 1,120.52 811.5 1,081 3,599 3,894 3,602 7,234 36,020 1,166.13 561.0 747 2,486 2,763 2,489 4,992 24,880 1,210.75 395.5 527 1,753 1,994 1,753 3,512 17,510 1,254.55 284.0 378 1,258 1,462 1,258 2,516 12,560 1,301.17 207.4 - 919 1,088 917 1,833 9,164 1,348.38 153.8 - 682 821 679 1,356 6,792 1,397.13 115.8 - 513 628 511 1,016 5,108 1,447.44 88.3 - 392 486 389 770 3,894 1,496.28 68.3 - 303 380 301 591 3,006 I E F D H J M T 10k Type 2 692,700 344,700 180,100 98,320 55,790 32,770 19,930 12,500 10,000 8,055 5,323 3,599 2,486 1,753 1,258 919 682 513 392 303 W 10k Type 3 454,910 245,089 137,307 79,729 47,843 29,588 18,813 12,272 10,000 8,195 5,593 3,894 2,763 1,994 1,462 1,088 821 628 486 380 Y 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 205 196 Temperature Monitoring | VAV Discharge Temperature Sensors TJ SERIES VAV Discharge Air Sensor for Reheat Applications TJ Easy installation Stainless steel duct probe with mounting flange Two wires 2-wire installation (optional quick disconnect)...installs in minutes VAV systems Installation-ready for VAV systems and plenum areas...saves money on job commissioning and warranty service Plenum rated Plenum rated cable standard Application flexibility 4" or 8" (102 mm or 204 mm) duct probes The TJ Series temperature sensors are highly accurate and cost effective, with trouble-free installation. The sensor is encased in a sturdy corrosion-resistant stainless steel probe. A variety of RTD/thermistor sensor and probe length options are available for maximum versatility in applications. SPECIFICATIONS Wiring 22 AWG; 2-wire: RTD/Thermistor Probe Stainless steel Operating Temp Probe: -25° to 105 °C (-13 to 221 °F) Wiring side: Up to 75 °C (167 °F) WARRANTY Limited Warranty 5 years Increased cable length affects the readings of lower resistance RTDs (100R platinum, RTD). * Room temperature offset documented on each unit. APPLICATIONS · VAV reheat boxes · Dual duct boxes · Fan coils · Prove that hot water valve or electric heat is functioning properly · Check individual reheating stages · Check for hot water valve leaks · Determine if damper actuators are functioning on dual duct boxes 197 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Temperature Monitoring | TJ Series DIMENSIONAL DRAWING 1.5" (38 mm) 2.0" (51 mm) 0.25" (6.3 mm) L 1.1" (28 mm) Optional 1/4" female quick disconnect 1.0" (26 mm) ORDERING INFORMATION Probe Length "L" TJ Sensor Type Output R Cal Certificate Option B = 4"(102mm) D = 8" (203mm) B = 100R platinum, RTD = Resistive C = 1k platinum, RTD D = 10k T2, Thermistor E = 2.2k, Thermistor F = 3k, Thermistor H = 10k T3, Thermistor I = 1k Balco (Nickel-iron) RTD J = 10k Dale, Thermistor K = 10k w/11k shunt, Thermistor M = 20k NTC, Thermistor N = 1800 ohm, Thermistor T = 100k, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor 0 = None 2 = 3-point NIST calibration Example: TJ B D R 2 0 = Standard 5 ft. cable, No QDs 1 = 1/4" Female Quick Disconnects (QD) 2 = 1/4" QDs with 8 ft. leadwires 3 = 10 ft. cable, no QDs 1 STANDARD RTD AND THERMISTOR VALUES Class Type Accuracy Temp. Response* Pt RTD 100 Ohm 1000 Ohm ±0.3°C ±0.3°C 0.00385 0.00385 curve curve PTC PTC Balco RTD 1000 Ohm ±1% @70°C PTC 2.2k ±0.2°C 0/70°C NTC 3k ±0.2°C 0/70°C NTC 10k Type 2 ±1.0°C -50/150°C NTC THERMISTOR 10k Type 3 10k Dale 20k ±0.2°C ±0.2°C Consult 0/70°C -20/70°C Factory NTC NTC NTC 100k 10k Type 2 10k Type 3 Consult ±0.1°C 20/70°C ±0.1°C Factory ±0.2°C 0/20°C 0/70°C NTC NTC NTC High Accuracy °C °F -50 -58 -40 -40 -30 -22 -20 -4 -10 14 0 32 10 50 20 68 25 77 30 86 40 104 50 122 60 140 70 158 80 176 90 194 100 212 110 230 120 248 130 266 Sensor Codes Z202030-0U 100 Ohm 80.306 84.271 88.222 92.160 96.086 100.000 103.903 107.794 109.735 111.673 115.541 119.397 123.242 127.075 130.897 134.707 138.506 142.293 146.068 149.832 B 1000 Ohm 803.06 842.71 882.22 921.60 960.86 1,000.00 1,039.03 1,077.94 1,097.35 1,116.73 1,155.41 1,193.97 1,232.42 1,270.75 1,308.97 1,347.07 1,385.06 1,422.93 1,460.68 1,498.32 C STANDARD RTD AND THERMISTOR VALUES (Ohms ) 1000 Ohm 2.2k 3k 10k Type 2 10k Type 3 10k Dale 20k NTC 100k 740.46 154,464 205,800 692,700 454,910 672,300 1,267,600 - 773.99 77,081 102,690 344,700 245,089 337,200 643,800 3,366,000 806.02 40,330 53,730 180,100 137,307 177,200 342,000 1,770,000 841.00 22,032 29,346 98,320 79,729 97,130 189,080 971,200 877.46 12,519 16,674 55,790 47,843 55,340 108,380 553,400 913.66 7,373 9,822 32,770 29,588 32,660 64,160 326,600 952.25 4,487 5,976 19,930 18,813 19,900 39,440 199,000 991.82 2,814 3,750 12,500 12,272 12,490 24,920 124,900 1,013.50 2,252 3,000 10,000 10,000 10,000 20,000 100,000 1,035.18 1,814 2,417 8,055 8,195 8,056 16,144 80,580 1,077.68 1,199 1,598 5,323 5,593 5,326 10,696 53,260 1,120.52 811.5 1,081 3,599 3,894 3,602 7,234 36,020 1,166.13 561.0 747 2,486 2,763 2,489 4,992 24,880 1,210.75 395.5 527 1,753 1,994 1,753 3,512 17,510 1,254.55 284.0 378 1,258 1,462 1,258 2,516 12,560 1,301.17 207.4 - 919 1,088 917 1,833 9,164 1,348.38 153.8 - 682 821 679 1,356 6,792 1,397.13 115.8 - 513 628 511 1,016 5,108 1,447.44 88.3 - 392 486 389 770 3,894 1,496.28 68.3 - 303 380 301 591 3,006 I E F D H J M T 10k Type 2 692,700 344,700 180,100 98,320 55,790 32,770 19,930 12,500 10,000 8,055 5,323 3,599 2,486 1,753 1,258 919 682 513 392 303 W 10k Type 3 454,910 245,089 137,307 79,729 47,843 29,588 18,813 12,272 10,000 8,195 5,593 3,894 2,763 1,994 1,462 1,088 821 628 486 380 Y 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 205 198 Temperature Monitoring | Averaging Temperature Sensors TA SERIES High Accuracy Averaging Sensors TA The TA Series is a flexible TA sensor which averages the temperature read across the entire length of the copper tubing, making it ideal for duct temperature measurements. TA Series sensors average the measured temperature across the duct in 6', 12', or 24' (1.8 m, 3.6 m, or 7.3 m) lengths. This allows you to cover all your averaging applications with one line. SPECIFICATIONS Wiring 22 AWG; 2-wire: RTD/Thermistor Operating Temp -25 to 105 °C (-13 to 221 °F)* LINITEMP OPTION Input Power Class 2; 5 to 30 Vdc Output 10mV/°C Operating Temp -25 to 105 °C (-13 to 221 °F) Calibration Error 1.5 °C (2.7 °F) typical; 2.5 °C (4.5 °F) max. at 25 °C (77 °F)* Error Over Temp 1.8 °C (3.24 °F) typical; 3.0 °C (5.4 °F) max. over 0 to 70 °C (32 to 158 °F) range; 2.0 °C (3.6 °F) typical, 3.5 °C (6.3 °F) max. over -25 to 105 °C (-13 to 221 °F) range WARRANTY Limited Warranty 5 years * Room temperature offset documented on each unit. APPLICATIONS · Heat exachangers · Chillers ORDERING INFORMATION Flexible Probe Length TA Sensor Type Calibration Certificate M = 6' (1.8m)* H = 12' (3.6m) J = 24' (7.3m) B = 100R platinum, RTD C = 1k platinum, RTD D = 10k, T2, Thermistor H = 10k, T3, Thermistor I = 1k Balco (Nickel-iron) RTD J = 10k, Dale, Thermistor M = 20k, NTC N = 1800 ohm, Thermistor P = 10mV/C, Linitemp R = 10k US, Thermistor 0 = None 2 = 3-point NIST calibration Example: TA H C2 * Available with sensor types I, J, N, P. DIMENSIONAL DRAWING 2.3" (58 mm) 1.8" (44 mm) 4.2" (107 mm) 4" (102 mm) ACCESSORIES AA64 Klipet Mounting Clip 0.5" (13 mm) Bendable Tubing 199 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com STANDARD RTD AND THERMISTOR VALUES Class Type Accuracy Temp. Response* Pt RTD 100 Ohm 1000 Ohm ±0.3°C ±0.3°C 0.00385 curve PTC 0.00385 curve PTC Balco RTD 1000 Ohm ±1% @70°C PTC 10k Type 2 10k Type 3 ±1.0°C ±0.2°C 10k Dale 10k "G" US 20k ±0.2°C ±0.2°C Consult -50/150°C 0/70°C -20/70°C 0/70°C Factory NTC NTC NTC NTC NTC °C °F -50 -58 -40 -40 -30 -22 -20 -4 -10 14 0 32 10 50 20 68 25 77 30 86 40 104 50 122 60 140 70 158 80 176 90 194 100 212 110 230 120 248 130 266 Sensor Codes STANDARD RTD AND THERMISTOR VALUES (Ohms ) 100 Ohm 1000 Ohm 1000 Ohm 10k Type 2 10k Type 3 10k Dale 80.306 803.06 740.46 692,700 454,910 672,300 84.271 842.71 773.99 344,700 245,089 337,200 88.222 882.22 806.02 180,100 137,307 177,200 92.160 921.60 841.00 98,320 79,729 97,130 96.086 960.86 877.46 55,790 47,843 55,340 100.000 1000.00 913.66 32,770 29,588 32,660 103.903 1039.03 952.25 19,930 18,813 19,900 107.794 1077.94 991.82 12,500 12,272 12,490 109.735 1097.35 1,013.50 10,000 10,000 10,000 111.673 1116.73 1,035.18 8,055 8,195 8,056 115.541 1155.41 1,077.68 5,323 5,593 5,326 119.397 1193.97 1,120.52 3,599 3,894 3,602 123.242 1232.42 1,166.13 2,486 2,763 2,489 127.075 1270.75 1,210.75 1,753 1,994 1,753 130.897 1308.97 1,254.55 1,258 1,462 1,258 134.707 1347.07 1,301.17 919 1,088 917 138.506 1385.06 1,348.38 682 821 679 142.293 1422.93 1,397.13 513 628 511 146.068 1460.68 1,447.44 392 486 389 149.832 1498.32 1,496.28 303 380 301 B C I D H J 10k "G" US 20k NTC 441,200 1,267,600 239,700 643,800 135,300 342,000 78,910 189,080 47,540 108,380 29,490 64,160 18,780 39,440 12,260 24,920 10,000 20,000 8,194 16,144 5,592 10,696 3,893 7,234 2,760 4,992 1,990 3,512 1,458 2,516 1,084 1,833 816.8 1,356 623.6 1,016 481.8 770 376.4 591 R M Temperature Monitoring | TA Series 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 200 Temperature Monitoring | Outdoor Temperature Sensors TO SERIES Sleek Design, Reduces Solar Heating Sleek design Reduces solar heating...reliable and accurate Flexibile Available with transmitter, linitemp, RTDs, or thermistors APPLICATIONS · Outdoor reference RTD/Thermistor Model Temperature Transmitter Model TO Series outdoor temperature sensors feature a sleek, weather resistant design, and provide easy installation. The durable probe is encased in a radiation shield to reduce the effects of solar heating. Choose from a variety of RTD, thermistor, or transmitter outputs to suit any application. SPECIFICATIONS Wiring 22 AWG; 2-wire: RTD/Thermistor, 4 to 20 mA; 3-wire: voltage output models Junction Box Weather resistant Mounting Location For outdoor use TEMPERATURE TRANSMITTER OPTION Input Power 4 to 20 mA version - Loop powered Class 2, 12 to 30 Vdc only, 30 mA max; 1-5/2-10 V versions - 12-30 Vdc/24 Vac, 50/60 Hz, 15 mA max Temp. Output 2-wire, loop powered Class 2, 4 to 20mA; 3-wire, 1-5 V/2-10 Vdc Sensor Type Solid-state, integrated circuit (Transmitter) Accuracy ±0.5°C (±.9°F) typical Ranges 0 to 50 °C (32 to 122 °F), -40 to 50 °C (-40 to 122 °F)* RESISTIVE OPTION Operating Temp -25 to 105 °C (-13 to 221 °F) WARRANTY Limited Warranty 5 years AGENCY APPROVALS RTD/THERMISTOR MODELS Dimensional Drawing 4.00" (101.57 mm) 4.30" (109.22 mm) 2.12" (53.72 mm) 3.51" (89.16 mm) TEMPERATURE TRANSMITTER MODELS Dimensional Drawing 3.4" (86 mm) 4.6" (116 mm) 3.9" (100 mm) 9.3" (237 mm) 2.8" (71 mm) 4.73" (102.14 mm) 0.9" (22 mm) 201 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ORDERING INFORMATION RTD/Thermistor Models Sensor Type Output Cal Certificate TO RØ B = 100R platinum, RTD = Resistive Output 0 = None C = 1k platinum, RTD 2 = 3-point NIST D = 10k T2, Thermistor calibration E = 2.2k, Thermistor F = 3k, Thermistor H = 10k T3, Thermistor I = 1k Balco (Nickel-iron) RTD J = 10k Dale, Thermistor K = 10k w/11k shunt, Thermistor Example: M = 20k NTC, Thermistor N = 1800 ohm, Thermistor TO C RØ 2 T = 100k, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor Temperature Monitoring | TO Series Temperature Transmitter Models Output TOA Range Calibration Certificate M = 4 to 20 mA V = 0-5/10 Vdc 1 = -40to 50 °C (-40 to 122 °F) 2 = 0 to 50 °C (32 to 122 °F) 0 = None 1 = 1-point Cal validation 2 = 2-point Cal validation Example: TOA M 1 0 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 202 Temperature Monitoring | Freeze Stats TZ SERIES Manual & Automatic Freeze Stats with Relay(s) Reset options Available in manual or automatic reset options Relay options All models feature one or two 15A SPDT relays TZ The TZ Series are low limit controllers, also known as "freeze stats". These devices are designed for use on HVAC equipment that require lowtemperature cutout protection to prevent cooling coils from freezing. They are mounted between the heating and cooling coils on the supply side of a fan unit and respond to the lowest temperature sensed along any one-foot section of the sensing element. The TZ Series offers manual and automatic reset versions, as well as, models that feature one or two sets of SPDT contacts. Numerous capillary lengths are also available. APPLICATIONS · Cooling coil frost monitoring · HVAC systems SPECIFICATIONS Thermostat Type Self-contained, electromechanical Sensing Element Vapor-filled capillary Sensing Media Temperature in air Sensing Temp. Operating Range 14 to 54 °F (-10 to 12 °C) Sensing Capillary Overload Temp. 392 °F (200 °C), maximum 60 minutes Sensing Response To lowest temperature sensed by any 1' section of the capillary element Sensing Capillary Material Copper Sensing Capillary Installation Duct and across coil mounted Sensing Capillary Length See Ordering Information Sensing Capillary Diameter Ø 0.08 in. (2 mm) (6' models have a larger bulb at the end Type of Control ON/OFF, low-level single-stage or cut-out control, with one (1) microswitch output Low-Level Setpoint (Factory Set) At 39 °F (4 °C), and safety-lock secured Low-Level Setpoint Visual Range 14 to 54 °F Low-Level Setpoint Adjustment Over full operating range, via screwdriver slot Contact Form Form 1C (SPDT Contact) Number of Relays See Ordering Information Max. Contact Switching Voltage 250 Vac Max. Contact Switching Current 15 (8) A Switching Differential 1.8 °F (1 °K), auto- or manual reset Enclosure Operating Temperature Range Operating Humidity Range Storage Temperature Range Enclosure Base Material Enclosure Cover Material Enclosure Color Enclosure NEMA Rating Cable Entry Wire Connections Maximum Wire Size Agency Approvals Product Weight Enclosure Product Dimensions (L x W x H) Limited Warranty 14 to 131 °F (-10 to 55 °C) 0 to 95% RH, non-condensing 14 to 158 °F (-10 to 70 °C) Steel, galvanized ABS, re retardant Silver /light gray NEMA 1 (IP40) One (1) M20 compression tting, removable, hole ts 1/2" conduit connector Terminal with wire-retaining screws 14 AWG (2.5 mm²) CE 1.6 lbs (0.7 kg) 4.1" (105 mm) x 3.3" (83 mm) x 2.1" (53 mm) 2 years 203 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Temperature Monitoring | TZ Series TZ10, TZ20, TZ50 Dimensional Drawing 4.53" (115.01 mm) Available in 6', 10', 20' & 50'capillary lengths Front View 4.35" (110.49 mm) Right View 2.18" (55.25 mm) Top View TZ06 Dimensional Drawing 4.53" (115.01 mm) 3.65" (92.71 mm) Ø 0.375" (9.53 mm) Front View Right View 2.18" (55.25 mm) 4.35" (110.49 mm) Top View 1-RELAY MODELS Wiring Drawing Setpoint Adjustment Screw Mounting Hole + oF 15 20 30 40 50 + oF 3 3 2 2 Common Ground Terminal Note: Falling temperature and attained low cut-out point. Contact connection: red to blue. Relay N/C Contact (white) Relay N/O Contact (blue) Manual Reset Button Relay Common (red) Mounting Hole PG13.5 Connector (1/2" Conduit Knockout) N/C (white) Common (red) N/O (blue) Schematic Diagram 2-RELAY MODELS Wiring Drawing Mounting Hole Setpoint Adjustment Screw Stage 1 Stage 2 + oF 15 20 30 40 50 + oF 3333 2222 Common Commoonn Relay N/C Contact (white) Relay N/O Contact (blue) Manual Reset Button Relay Common (red) Mounting Hole Ground Terminal PG13.5 Connector (1/2" Conduit Knockout) Note: Falling temperature and attained low cut-out point. Contact connection: red to blue. Schematic Diagram N/C (white) Common (red) N/O (blue) N/C (white) Common (red) N/O (blue) ORDERING INFORMATION Probe Length TZ Number of Relays 06 = 6' (1.8 m) 10 = 10' (3 m) 20 = 20' (6 m) 50 = 50' (16 m) 1 = 1 relay* 2 = 2 relays * Not available in 50' (16 m) version. Reset Example: TZ 20 1 M A = Automatic M = Manual ACCESSORIES Klipet Mounting Clip (AA64) ACCESSORIES P. 205 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 204 Temperature Monitoring | Accessories ACCESSORIES: TEMPERATURE MONITORING AA22, AA24, AA25 AA24 2-1/2" (64 mm) thermowell AA22 4" (102 mm) thermowell AA25 6" (152 mm) thermowell AA64 Klipet Mounting Clip AA10 The AA10 Series temperature-to-current transmitter is designed for use with 100R platinum, 1k platinum, 10k Type 2, and 10k Type 3 external resistive output devices. When the resistive output from the external device is connected to the AA10 input terminal, the resistive value is converted to a 4-20 mA signal compatible with most building control systems. Dimensional Drawing 1.5" (39 mm) Ø 0.3" (8 mm) Ø 0.2" (5 mm) 0.75" (20 mm) 0.8" (21 mm) 1.5" (39 mm) 0.5" (13 mm) 1.5" (39 mm) Ordering Information 4-20mA Temperature Sensor Output Range* Sensor Type Bottom Range Temp Temp Scale Top Range Temp AA10 B = 100R platinum, RTD = (choose a valid C = 1k platinum, RTD temp value) D = 10k T2, Thermistor H = 10k T3, Thermistor W = 10k T2 high accuracy, Thermistor Y = 10k T3 high accuracy, Thermistor C = Celsius F = Farenheit * Temperature output range must be whole numbers where the bottom value is less than the top value in the range. Output temperature ranges: B and C sensor types: -50° to 150°C (-58° to 302°F); D, H, W and Y sensor types: -25° to 105°C (-13° to 221°F) = (choose a valid temp value) AA04 The AA04 remote display converts a standard 4-20 mA output from an environmental sensor into a convenient digital readout. 4.3" 109 mm 2.5" 62 mm 3.9" 98 mm 1.2" 28 mm Wiring Diagram, 2-Wire, Loop powered, Sinking Transmitter POWER SUPPLY + 12 to 24 VDC Veris #PS-24 RED + BLK 1888 DIGITAL CONTROL + 4-20mA Return Wiring Diagram, 3-Wire, Sourcing Transmitter + POWER SUPPLY 12 to 24 VDC Veris #PS-24 +-0 RED + BLK 1888 205 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Temperature Monitoring | Accessories 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 206 OCCUPANCY SENSORS Veris offers a selection of motion-activated lighting control devices for commercial building applications. Keep costs down by preventing wasteful and unnecessary use of energy. With two mounting styles and an adjustable time delay, these sensors provide control over the lighting of rooms up to 2000 square feet. The installation is simple and the housings are low profile. MODEL MSC MSB DESCRIPTION Ceiling Mount Occupancy Sensors Wall Switch Occupancy Sensors PAGE 209 211 LIGHTING CONTROL SELECTION GUIDE CEILING MOUNT MSC page 209 WALL MOUNT MSB page 211 207 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com LIGHT UP A SPACE ONLY WHEN IT'S OCCUPIED MSX Series Occupancy Sensors APPLICATIONS » Lighting control based on occupancy » Reduces energy usage » Key component for LEED® certification programs, retrofit installations » MSC1000--best for conference rooms, classrooms and other general applications » MSD2000--best for multi-stall restrooms, large conference rooms and warehouses » MSCU2000--best for lobbies, aisles, and great for multi-stall restrooms Note: Leadership in Energy and Environmental Design (LEED) is a registered mark of the US Green Building Council FEATURES WIDE COVERAGE Up to 2000 square foot coverage area and 360-degree field of view for application versatility DAYLIGHT SENSING Daylight level sensing avoids unnecessary lighting ADJUSTABLE TIME DELAY Adjustable time delay presets provide ultimate flexibility AUXILIARY RELAY Easily communicates with building control system ADJUSTABLE COVERAGE Adjustable coverage sensitivity from 60 to 100% TAMPER RESISTANT COVER Tamper resistant adjustment compartment cover 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 208 Occupancy Sensors | Ceiling Mount Occupancy Sensors MSC SERIES Uses the Latest Passive Infrared and Ultrasonic Technologies MSCD/MSCP MSCU Wide coverage Up to 2000 square foot coverage area and 360-degree field of view for application versatility Adjustable coverage Adjustable coverage sensitivity (from 60 to 100%) Daylight sensing Daylight level sensing (from 0.5 to 250 foot-candles)... avoids unneccessary lighting Auxiliary relay Easily communicates with building control system MSC Series Occupancy Sensors employ passive infrared (PIR) and/or ultrasonic technologies to accurately detect occupancy and automatically switch room lighting. The low-profile sensor is ceiling-mounted to maximize motion sensitivity in large areas with obstructions. With a 360 degree field of view, and up to 2000 square feet of coverage area, the ceiling-mounted occupancy sensor is ideal for conference rooms, classrooms, multi-stall bathrooms, and large office areas. The MSC series also incorporates an integral photosensor to prevent lights from switching on when sufficient ambient light is present, as commonly found in windowed areas. Installation and configuration are simple. The sensor readily mounts to drop ceilings, and it features front adjustments for setting sensitivity and time delay. The sensor also features an auxiliary relay for use with building automation and HVAC systems. SPECIFICATIONS Standards UL and cUL Listed; FCC part 15 (Class B) for home and office use Input Voltage 24 Vdc Isolated Relay Contact rating: 1 A@24 Vdc Resistive Temperature 0 to 50 °C (32 to 122 °F) Humidity Max. 90% RH non-condensing CURRENT CONSUMPTION @ 24 VDC* PIR 21 mA nominal Ultrasonic 34 mA nominal Dual 37 mA nominal DIMENSIONS MSCU 4.6" (117 mm) diameter, 1.4" (35.1 mm) high MSCD/MSCP 4.6" (117 mm) diameter, 1.8" (45.7 mm) high WARRANTY Limited Warranty 5 years AGENCY APPROVALS * For local line switching control, power must be provided by AA47 power pack or an approved equivalent. Adjustable time Tamper resistant delay cover Adjustable time delay (preset time delays from 15 seconds [test] to 30 minutes)...provides ultimate flexibility Adjustment compartment cover...tamper resistant APPLICATIONS · Lighting control based on occupancy · Reducing energy usage · Key component for LEED* certification programs retrofit installations · MSCD2000 best for multi-stall bathrooms, large conference rooms, and warehouses · MSCU2000 best for lobbies, aisles, and great for multi-stall bathrooms · MSC1000 best for conference rooms, classrooms, and other general applications *Leadership in Energy and Environmental Design (LEED) is a registered mark of the US Green Building Council MSC SERIES Coverage Patterns for 9 ft (2.8 m) Ceiling Height PIR Sensor Ultrasonic Sensor 25 ft (7.7m) 32 ft (9.8m) Minor Motion Major Motion 30 ft (9.2m) 48 ft (14.7m) 24 ft 42 ft (7.4m) (12.8m) Ultrasonic Major Motion Ultrasonic Minor Motion PIR Major Motion PIR Minor Motion 209 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Occupancy Sensors | MSC Series LOCAL LINE-POWER CONTROL MSC Wiring Diagram Class 2 Black Blue Red Red Blue Black Black Blue Red Class 1 Hot Neutral Black White Power Pack Red AA47 Load Orange (N.O.) Yellow (Common) Green (N.C.) Additional Sensor(s) (optional) Contact rating: 1 A @ 24 Vdc Resistive Aux. Relay AA47 LOCAL LINE SWITCHING POWER PACK System Diagram Hot Line Voltage 120/277 Vac Neutral BLK White RED 120 V Voltage Selector 277 V Ext. Override OFF Load +24 Vdc Common Control Input BLUE BLK RED Sensor AA48 AUXILARY RELAY (OPTIONAL) System Diagram Neutral Hot Override OFF Load Red +24 Vdc (Red) White AA47 Power 0 Vdc (Blk) Pack Control (Blue) Black Load Load Ext. Override OFF Red AA48 Optional Auxiliary Relay Red Hot Sensor ORDERING INFORMATION Sensing Technology MSC U = Ultrasonic D = PIR + Ultrasonic P = Passive Infrared (PIR) Coverage 1000 = 1000 Sq. Ft. (Passive Infared only) 2000 = 2000 Sq. Ft. (Ultrasonic or Dual technology only) Example: MSC D 2000 BUILDING CONTROL PANEL Wiring Diagram 24 Vdc + - +24 Vdc BLK RED BLK RED COMMON CONTROL IN ORG N.O. or GRN N.C. CONTROL IN ORG N.O. or GRN N.C. The AA47 Line-Switching Power Pack provides local switching capability to control loads at a signal from MSC Series occupancy sensors, independent of any connection to building control systems. The AA47 routes 120/277 Vac, 60 Hz line power directly to a Form A relay contact (SPST) to control a load and generates full-wave, 24 Vdc to power up to four MSC sensors (dependent on model). The AA47 can be mounted either inside or outside an electrical box, and sensor power can be routed via plenum-rated cable to the sensor(s). SPECIFICATIONS AA47 Storage Temp. Operating Temp. Maximum Humidity AC Power Input Output Voltage Output Current Dimensions RELAY CONTACTS Horsepower Rating Switching Capacity -29 to 65 °C (-20 to 150 °F ) 0 to 40 °C (32 to 104 °F) 90% RH non-condensing 120/277 Vac ± 10%, 60 Hz 24 Vdc 100 mA max. 3.2" (81.3 mm) x 3" (76.2 mm) x 1.75" (44.5 mm) 1HP@120 V 120 Vac, 60 Hz; 15 A tungsten 1800 W 277 Vac, 60 Hz; 20 A ballast The AA48 Auxiliary Relay is a low-voltage relay device for expanding the switching capacity of an AA47. It can be used to control loads connected to additional circuits in response to a signal from a connected sensor. It is essentially a relay with a SPST output controlled directly by the occupancy sensor. The auxiliary relay can be mounted inside or outside of an electrical junction box. SPECIFICATIONS AA48 Storage Temperature Operating Temperature Maximum Humidity Control Input Dimensions RELAY CONTACTS Horsepower Rating Switching Capacity -29 to 65 °C (-20 to 150 °F ) 0 to 40 °C (32 to 104 °F) 90% RH non-condensing 24 Vdc, 36 mA nominal 3.2" (81.3 mm) x 3" (76.2 mm) x 1.75" (44.5 mm) 1HP@120 V 120 Vac, 60 Hz; 15 A tungsten 1800 W 120/277 Vac, 60 Hz; 20 A ballast 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 210 Occupancy Sensors | Wall Switch Occupancy Sensors MSB SERIES Employs a Low-Energy Switch Circuit to Maximize Contact Life MSBP Adjustable Adjustable time delay Bypass button Bypass button for "always on" operability...simpilifies commissioning 180-degree motion detection 180 degrees 180-degree motion detection Line powered No separate supply needed Ballast compatibility Compatible with magnetic and electronic ballasts...provides ultimate flexibility Loading No minimum loading requirement The MSB Series employs the latest passive infrared (PIR) technology to automatically control lighting for areas up to 1000 square feet, achieving energy savings and convenience. Each sensor employs a special 180° multi-segmented lens and PIR motion detector circuit to sense when a person enters the area and automatically activate the lights. The sensor will automatically switch the lights off after a preset delay if motion is no longer detected. The MSB Series fits in place of existing wall switches, connecting to existing wiring, similar to a typical wall switch. The MSB Series is the simplest way to achieve energy saving lighting control with minimal installation time. To assure long relay life, the MSB Series employs a low energy switch circuit to assure maximum contact life. These sensors are compatible with electronic and magnectic ballast loads. APPLICATIONS · Lighting control for LEED* programs and reduced energy usage · Use in offices, copy rooms, common building areas, storage closets, small conference rooms, and more · Fits in place of existing wall switches connecting to the existing active line and ground wiring...great for retrofit installations *Leadership in Energy and Environmental Design (LEED) is a registered mark of the US Green Building Council MSB SERIES Coverage Patterns SPECIFICATIONS Standards Input Output Temperature Humidity WARRANTY Limited Warranty AGENCY APPROVALS UL and cUL Listed; FCC part 15 (Class B) for home and office use 120 or 277 Vac±10% 60 Hz 120 Vac, 1000 W max. tungsten incandescent load; 1000 VA max. ballast load; ¼ HP max. motor load; 277 Vac; 1800 VA max. ballast load 0 to 50 °C (32 to 122 °F) Max. 90% RH non-condensing 5 years Top View 35 ft (10.7m) 10 ft (3.1m) 15 ft (4.6m) 25 ft (7.6m) Side View 4 ft (1.2m) 35 ft (10.7m) Minor Motion Major Motion 211 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com SINGLE-LEVEL LIGHTING Wiring Diagram Neutral (WHT) Ground (GRN) Hot (BLK) LOAD (RED) BI-LEVEL LIGHTING Wiring Diagram Neutral (WHT) Ground (GRN) (RED) Hot (BLK) LOAD LOAD Occupancy Sensors | MSB Series MSB SERIES Dimensional Drawings 4.2" (107 mm) 1.8" (46 mm) 1.3" (33 mm) 4.5" (114 mm) 2.8" (69 mm) ORDERING INFORMATION Sensing Technology MSB P = Passive Infrared (PIR) Turn On # of Circuits 1 Color A = Automatic M = Manual W = White V = Ivory Example: MSB P A 1 V 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 212 SETPOINT DEVICES The Veris line of thermostats and humidistats will help you guarantee accurate climate control in buildings with or without a central BAS controller. These devices can be programmed for independent control of dedicated mechanical equipment and can interface with a control system to report status via analog, protocol, or wireless communications. MODEL VIC-VT7200 VIC-VT7300 VIC-VT8350 VIC-VT7600 VIC-VT8650 VIC-VTR835X0A5X/ VIC-VC3XXXE5000 VIC-VH7200 VZ7000 VZ8250 DESCRIPTION Zoning Thermostats Fancoil Thermostats Room Temperature Controllers Rooftop Unit Thermostats Room Temperature and Indoor Air Quality Controllers Fancoil Thermostats, Retrofit Solution Communicating Humidistat Series Zone Terminal Equipment Controllers Variable Air Volume (VAV) Unit Controllers PAGE 215 217 219 221 223 225 227 229 231 213 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCURATE, OPTIMAL CLIMATE CONTROL Rooftop Unit, Heat Pump, and Indoor Air Quality Controller APPLICATIONS » Commercial and hospitality buildings as a standalone device or integrated into a Building Management System FEATURES TOUCHSCREEN Customizable digital interface with multi-language support COMMUNICATIONS BACnet MSTP Modbus RTU Optional Zigbee Pro Wireless CONFIGURABLE Sequence of operations Economizer and scheduler Control sequences using scripting WIDE RANGE OF SENSORS Temperature Humidity with on-board humidification strategy Optional occupancy (PIR) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 214 Setpoint Devices | Communicating Thermostats: Analog or Floating Outputs, Zone Control VIC-VT7200 SERIES BACnet, LonWorks, Zigbee and Zigbee Pro Models Available Advanced occupancy functions Advanced occupancy functions through the network or smart local occupancy sensing Auxiliary output Can be used for lighting or reheating Minimize parameter tampering Unique local configuration utility Lockable keypad Tamper resistant, no need for thermostat guards VT7200 VT7200 Smart energy management has never been easier than with the VIC-VT7200. Designed for new construction or retrofit projects, the controllers dramatically decrease total costs by reducing installation time, configuration and commissioning time. The VIC-VT7200 provides the advanced features and monitoring functions required by modern building automation systems without the use of software and commissioning tools. This application is known as Variable Air Volume (VAV). Pre-configured sequences Pre-configured sequences of operation...one model meets more applications and reduces project delivery cost APPLICATIONS · Heating/Cooling valves · Electric duct heaters Configurable inputs Three configurable inputs for added functionality · Changeover sensors SPECIFICATIONS Thermostat Power Requirements 19 to 30 Vac; 50 or 60 Hz; 2 VA Class 2 Operating Conditions 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing Storage Conditions -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Temperature Sensor Local 10k NTC thermistor Resolution ± 0.1 °C (± 0.2 °F) Control Accuracy Temp. ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical, calibrated Occupied and Unoccupied 12 to 38 °C (54 to 100 °F) Setpoint Range Cooling Occupied and Unoccupied 4.5 to 32 °C (40 to 90 °F) Setpoint Range Heating Room and Outdoor Air Temperature Display -40 to 50 °C (-40 to 122 °F) Proportional Band for Room Cooling & Heating: 1.8 °C (3.2 °F ) Temperature Range Control Binary Inputs Dry contact across terminal BI1, BI2 & UI3 to Scom Outputs Rating Triac output: 30 Vac, 1 A max., 3 A in-rush; Analog: 0 to 10 Vdc into 2k resistance min. Economizer Analog Output Rating Economizer Analog Output Accuracy Wire Gauge Dimensions Approximate Shipping Weight WARRANTY Limited Warranty AGENCY APPROVALS 0 to 10 Vdc into 2k resistance min. ±3% typical 18 gauge maximum, 22 gauge recommended 4.94" x 3.38" x 1.13" 0.75 lb (0.34 kg) 2 years UL: 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN , XAPX (US) and XAPX7 (Canada) FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US) Industry Canada: ICES-003 (Canada) CE: EMC Directive 2004/108/EC (European Union) 215 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING Setpoint Devices | VIC-VT7200 Series 4.9" (125 mm) 1.25" (32 mm) 3.4" (87 mm) 1.1" (28 mm) 1.5" (37 mm) ORDERING INFORMATION PART # VIC-VT7200C5031 VIC-VT7200C5031B VIC-VT7200C5531B VIC-VT7200C5531E VIC-VT7200C5531P VIC-VT7200C5531W VIC-VT7200F5031 VIC-VT7200F5031B VIC-VT7200F5531B VIC-VT7200F5531E VIC-VT7200F5531P VIC-VT7200F5531W DESCRIPTION COMM. Zone Controller: Net Ready, Floating Outputs, VAV PD Standalone Zone Controller: BACnet, Floating Outputs, VAV PD BACnet MS/TP PIR Zone Controller: 2 On/Off or Floating Outputs BACnet MS/TP PIR Zone Controller: 2 On/Off or Floating Outputs LonWorks PIR Zone Controller: 2 On/Off or Floating Outputs Zigbee Pro PIR Zone Controller: 2 On/Off or Floating Outputs Zigbee Zone Controller: Net Ready, 2 Analog 0-10V Outputs, VAV PD Standalone Zone Controller: BACnet, 2 Analog 0-10V Outputs, VAV PD BACnet MS/TP PIR Zone Controller: 2 Analog 0-10V Outputs BACnet MS/TP PIR Zone Controller: 2 Analog 0-10V Outputs LonWorks PIR Zone Controller: 2 Analog 0-10V Outputs Zigbee Pro PIR Zone Controller: 2 Analog 0-10V Outputs Zigbee Note: For combinations not listed here, a SKU with PIR and com can be purchased as: 1 Room Controller + 1 Com Module + 1 Cover with PIR. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 216 Setpoint Devices | Communicating Thermostats: Analog or Floating Outputs, Fancoil Control VIC-VT7300 SERIES BACnet, LonWorks, Zigbee and Zigbee Pro Models Available Available internal humidity sensing Increased occupant comfort through dehumidification Configurable inputs Three configurable inputs for added functionality Configurable sequences Configurable sequences of operation...single model meets more applications Configurable fan Configurable fan functions button including ECM and speed fan control...meets multiple applications with a single model VIC-VT7350C5031 VIC-VT7350C5531 The VIC-VT7300 provides the advanced features and monitoring functions required by modern building automation systems without the use of software and commissioning tools. The VIC-VT7300 is a low voltage fan coil terminal equipment controller suitable for commercial and hospitality markets. It can also be used as a zone controller or mixed voltage solution. SPECIFICATIONS Thermostat Power Requirements VT7350: 19 to 30 Vac; 50 or 60 Hz; 2 VA Class 2 VTR7350: 7.0 Vdc +/- 10%, 2.4 W min. Operating Conditions 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing Storage Conditions -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Temperature Sensor Local 10k NTC thermistor Resolution ±0.1 °C (± 0.2 °F) Control Accuracy: Temperature Humidity ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical, calibrated ±3% from 20 to 70% RH at 21 °C (70 °F) Occupied and Unoccupied 12 to 38 °C (54 to 100 °F) Setpoint Range Cooling Occupied and Unoccupied 4.5 to 32 °C (40 to 90 °F) Setpoint Range Heating Room and Outdoor Air Temperature Display -40 to 50 °C (-40 to 122 °F) Proportional Band for Room Cooling & Heating: 1.8 °C (3.2 °F ) Temperature Range Control Binary Inputs Dry contact across terminal BI1, BI2 & UI3 to Scom* Outputs Rating Triac output: 30 Vac, 1 A max., 3 A in-rush; Analog: 0 to 10 Vdc into 2k resistance min.* Economizer Analog Output 0 to 10 Vdc into 2k resistance min. Rating Economizer Analog Output ±3% typical Accuracy Advanced occupancy functions Advanced occupancy functions through the network or smart local occupancy sensing APPLICATIONS · Three-speed fans · Heating/cooling valves · Electric duct heaters · Changeover sensors Minimize parameter tampering Unique local configuration utility · Line Voltage with additional relay pack · Low voltage room controllers Wire Gauge Dimensions Approximate Shipping Weight WARRANTY Limited Warranty AGENCY APPROVALS 18 gauge maximum, 22 gauge recommended 4.94" x 3.38" x 1.13" 0.75 lb (0.34 kg) 2 years UL: 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN , XAPX (US) and XAPX7 (Canada) FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US) Industry Canada: ICES-003 (Canada) CE: EMC Directive 2004/108/EC (European Union) DIMENSIONAL DRAWING 4.9" (125 mm) 1.25" (32 mm) 3.4" (87 mm) 1.1" (28 mm) 1.5" (37 mm) 217 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Setpoint Devices | VIC-VT7300 Series ORDERING INFORMATION PART NUMBER DESCRIPTION ECM Hotel or Commercial Applications VIC-VT7300F5031B-ECM ECM FCU Room Controller: BACnet, 2 Analog 0-10V Outputs, Commercial Interface VIC-VT7305F5031B-ECM ECM FCU Room Controller: BACnet, 2 Analog 0-10V Outputs, Hotel Interface Low Voltage Fan Speed Commercial Applications - Floating Outputs VIC-VT7350C5031 Fan Coil Controller: Net Ready, Floating Outputs, with Humidity, Commercial Interface VIC-VT7350C5031B Fan Coil Controller: BACnet, Floating Outputs, with Humidity, Commercial Interface VIC-VT7350C5531B PIR FCU Room Controller: 2 On/Off or Floating Outputs, with Humidity, Commercial Interface VIC-VT7350C5531E PIR FCU Room Controller: 2 On/Off or Floating Outputs, with Humidity, Commercial Interface VIC-VT7350C5531P PIR FCU Room Controller: 2 On/Off or Floating Outputs, with Humidity, Commercial Interface VIC-VT7350C5531W PIR FCU Room Controller: 2 On/Off or Floating Outputs, with Humidity, Commercial Interface Low Voltage Fan Speed Commercial Applications -Analog Outputs VIC-VT7350F5031 Fan Coil Controller: Net Ready, 2 Analog 0-10V Outputs, with Humidity VIC-VT7350F5031B Fan Coil Controller: BACnet, 2 Analog 0-10V Outputs, with Humidity VIC-VT7350F5531B PIR FCU Room Controller: 2 Analog 0-10V Outputs, with Humidity, Commercial Interface VIC-VT7350F5531E PIR FCU Room Controller: 2 Analog 0-10V Outputs, with Humidity, Commercial Interface VIC-VT7350F5531P PIR FCU Room Controller: 2 Analog 0-10V Outputs, with Humidity, Commercial Interface VIC-VT7350F5531W PIR FCU Room Controller: 2 Analog 0-10V Outputs, with Humidity, Commercial Interface Low Voltage Fan Speed Hotel Applications - Floating Outputs VIC-VT7355C5031 Fan Coil Controller: Net Ready, Floating Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355C5031B Fan Coil Controller: BACnet, Floating Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355C5531B PIR FCU Room Controller: 2 On/Off or Floating Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355C5531E PIR FCU Room Controller: 2 On/Off or Floating Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355C5531P PIR FCU Room Controller: 2 On/Off or Floating Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355C5531W PIR FCU Room Controller: 2 On/Off or Floating Outputs, with Humidity, Lodging/Hotel Interface Low Voltage Fan Speed Hotel Applications -Analog Outputs VIC-VT7355F5031 Fan Coil Controller: Net Ready, With Humidity, 2 Analog 0-10V Outputs, Lodging/Hotel Interface VIC-VT7355F5031B Fan Coil Controller: BACnet, 2 Analog 0-10V Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355F5531B PIR FCU Room Controller: 2 Analog 0-10V Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355F5531E PIR FCU Room Controller: 2 Analog 0-10V Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355F5531P PIR FCU Room Controller: 2 Analog 0-10V Outputs, with Humidity, Lodging/Hotel Interface VIC-VT7355F5531W PIR FCU Room Controller: 2 Analog 0-10V Outputs, with Humidity, Lodging/Hotel Interface Line Voltage Fan Speed Commercial Applications* VIC-VTR7350A5031 Fan Coil Controller: Net Ready, with Humidity, Commercial Interface VIC-VTR7350A5031B Fan Coil Controller: BACnet, with Humidity, Commercial Interface VIC-VTR7350A5531B PIR FCU Room Controller: with Humidity, Commercial Interface VIC-VTR7350A5531P PIR FCU Room Controller: with Humidity, Commercial Interface VIC-VTR7350A5531W PIR FCU Room Controller: with Humidity, Commercial Interface Line Voltage Fan Speed Hotel Applications* VIC-VTR7355A5031 Fan Coil Controller: Net Ready, with Humidity, Lodging/Hotel Interface VIC-VTR7355A5031B Fan Coil Controller: with Humidity, Lodging/Hotel Interface VIC-VTR7355A5531B PIR FCU Room Controller: with Humidity, Lodging/Hotel Interface VIC-VTR7355A5531P PIR FCU Room Controller: with Humidity, Lodging/Hotel Interface VIC-VTR7355A5531W PIR FCU Room Controller: with Humidity, Lodging/Hotel Interface * I/O relay pack required for VIC-VTR7350. COMM. BACnet MS/TP BACnet MS/TP Standalone BACnet MS/TP BACnet MS/TP LonWorks Zigbee Pro Zigbee Standalone BACnet MS/TP BACnet MS/TP LonWorks Zigbee Pro Zigbee Standalone BACnet MS/TP BACnet MS/TP LonWorks Zigbee Pro Zigbee Standalone BACnet MS/TP BACnet MS/TP LonWorks Zigbee Pro Zigbee Standalone BACnet MS/TP BACnet MS/TP Zigbee Pro Zigbee Standalone BACnet MS/TP BACnet MS/TP Zigbee Pro Zigbee 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 218 Setpoint Devices | Room Temperature Controllers VIC-VT8350 SERIES BACnet C and BACnet MS/TP with Zigbee Models Available Commercial and hospitality Suitable for both commercial and hospitality markets and systems Optional humidity sensor Humidity sensor with on-board humidification strategy (optional) Wi-Fi option BACnet/IP and email notification via Wi-Fi (with VCM8002V5031) Optional cover Optional occupancy sensor cover VIC-VT8350 Smart energy management has never been easier than with the VIC-VT8350 Series Fan Coil Room Controllers. Designed for new construction and retrofit projects, the Room Controllers dramatically decrease project delivery costs by reducing installation, configuration and commissioning time. No complex software or tools are required to customize functionality in order to meet your applications requirements. The Room Controllers provide all the advanced features and monitoring functions required by modern building automation systems in a simple compact enclosure. The VIC-VT8350 Room Controllers, part of the VIC-VT8000 family, are both application-specific AND programmable. This enables the modification of pre-configured control sequences, or the creation of entirely new control sequences for fan coil applications. Their configurable control sequences, economizer and scheduler functionalities deliver all the flexibility necessary for optimal indoor air quality applications. SPECIFICATIONS Thermostat Power Requirements Operating Conditions Storage Conditions Temperature Sensor Temp. Sensor Resolution Temp. Control Accuracy Humidity Sensor and Calibration Humidity Sensor Precision Humidity Sensor Stability Dehumidification Setpoint Range Occupied and Unoccupied Setpoint Range Cooling 7.0 Vdc ± 10%, 2.4 W min.; 24 Vac ± 15%; 50/60 Hz; 6 to 100 VA (rating max.) 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Local 10k NTC type 2 thermistor ± 0.1 °C (± 0.2 °F) ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical calibrated Single point calibrated bulk polymer sensor Reading range from 10 to 90% RH noncondensing 10 to 20% precision is 10%; 20 to 80% precision is 5%; 80 to 90% precision is 10% <1.0% annual drift (typical) 30 to 95% RH 12 to 38 °C (54 to 100 °F) Digital touch screen Customizable color digital touch screen interface with multi-language support 7-day occupancy scheduling 2 to 4 events Advanced occupancy functions For commercial and lodging applications Occupied and Unoccupied 5 to 32 °C (40 to 90 °F) Setpoint Range Heating Room and Outdoor Air Temperature Display -40 to 50 °C (-40 to 122 °F) Proportional Band for Room Cooling & Heating: 1.8 °C (3.2 °F ) Temperature Range Control Binary Inputs Dry contact across terminal BI1, BI2 and UI3 to Scom Economizer Analog Output 0 to 10 Vdc into 2k resistance min. Rating Economizer Analog Output ±3% typical Accuracy Wire Gauge 18 gauge maximum, 22 gauge recommended WARRANTY Limited Warranty 18 months AGENCY APPROVALS UL: 61010-1 (2nd edition); CSA: 61010-1 (3rd edition); IEC: 61010-1 (3rd edition), EN 60950-1: 2006A2: 2013, UL 873, CSA 22.2 No. 24-93; 61326-1:2005; FCC: Part 15, Subpart B; CE: EMC Directive 2004/108/EC (European Union); wireless models: FCC Part 15, Subpart C; R&TTE Directive 1999/5/EC; EN: 301 489-1 V1.9.2, 301 328 V1.8.1; RSS 210 219 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Setpoint Devices | VIC-VT8350 Series TYPICAL ZONE CONTROLLER APPLICATION Wiring Examples DIMENSIONAL DRAWING Supply Air Cooling Only VAV Heating Coil H C To Di user Baseboard Reheat BACnet MS/TP VIC-VT8300 as a Zone Controller Standard wired BACnet MS/TP communication and optional Zigbee Pro communication module upgrade 4.7" (120 mm) TYPICAL LOW VOLTAGE FAN COIL APPLICATION Wiring Examples 3-Speed Fan Cooling Coil Return Air Heating Coil Supply Air 3.4" (86 mm) Filter Status Switch Fan Status Switch 1.0" (25 mm) Standard wired BACnet MS/TP communication and optional Zigbee Pro communication module upgrade Existing Field Wires VIC-VT8350 Low Voltage Fan Coil Terminal Equipment Controller Optional Wireless Accessories Base Connecting Thermostat Zigbee Pro Communication Module Water Leak Wireless Sensor CO2 Wireless Module Door/Window WirelessSensor Wall/Ceiling Wireless Sensor Wi-Fi Module SELECTABLE COLOR SCHEMES ORDERING INFORMATION PART # DESCRIPTION VIC-VT8350U5000B RH, Fancoil Control, Low Voltage, BACnet MS/TP VIC-VT8350U5500B RH, PIR, Fancoil Control, Low Voltage, BACnet MS/TP VIC-VT8350U5500BP RH, PIR Room Controller, BACnet MS/TP and Zigbee 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 220 Setpoint Devices | Communicating Thermostats: Rooftop Control VIC-VT7600 SERIES BACnet MS/TP, LonWorks, Zigbee and Zigbee Pro Models Available PI time proportioning PI time proportioning algorithm for increased comfort, accuracy, and energy savings Local configuration Unique local configuration utility minimizes parameter tampering Two digital inputs Lockable keypad Two digital inputs for added functionality Tamper resistant, no need for thermostat guards Smart fan Saves energy during night mode Freeze protection Limits costly freeze damage VIC-VT7600A5000 Primarily designed for use in small to mid-sized commercial building applications, VIC-VT7600 room controllers can be installed in any building using a standard rooftop or heat pump unit with a requirement for advanced fresh air control. Capable of controlling economizer-free cooling and demand-based ventilation strategies, the VIC-VT7600 provides fresh air measurement input right out of the box. APPLICATIONS · Single-speed fans · Outdoor air temperature sensor · Supply air temperature sensor · Differential pressure switch SPECIFICATIONS Thermostat Power Requirements Operating Conditions Storage Conditions Temperature Sensor Resolution Control Accuracy Occupied and Unoccupied Setpoint Range Cooling Occupied and Unoccupied Setpoint Range Heating Room and Outdoor Air Temperature Display Proportional Band for Room Temperature Range Control Binary Inputs Output Rating Economizer Analog Output Rating Economizer Analog Output Accuracy Wire Gauge 19 to 30 Vac; 50 or 60 Hz; 2 VA Class 2 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Local 10k NTC thermistor ± 0.1 °C (± 0.2 °F) Temp: ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical calibrated 12 to 37.5 °C (54 to 100 °F) 4.5 to 32 °C (40 to 90 °F) -40 to 50 °C (-40 to 122 °F) Cooling & Heating: 1.8 °C (3.2 °F ) BI2 and UI3 to Scom 30 Vac, 1 A max., 3 A in-rush 0 to 10 Vdc into 2k resistance min. ±3% typical 18 gauge maximum, 22 gauge recommended Dimensions Approximate Shipping Weight WARRANTY Limited Warranty AGENCY APPROVALS 4.94" x 3.38" x 1.13" (12.5 x 86 x 30 mm) 0.75 lb (0.34 kg) 2 years UL: 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN , XAPX (US) and XAPX7 (Canada) FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US) Industry Canada: ICES-003 (Canada) CE: EMC Directive 2004/108/EMC (European Union). C-Tick: AS/NZS CISPR 22 Compliant (Australia / New Zealand); Supplier Code Number N10696 DIMENSIONAL DRAWING 4.9" (125 mm) 1.25" (32 mm) 3.4" (87 mm) 1.1" (28 mm) 1.5" (37 mm) 221 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Setpoint Devices | VIC-VT7600 Series ORDERING INFORMATION PART NUMBER SCHEDULING ECONOMIZER Rooftop Unit Controller VIC-VT7652B5031 X VIC-VT7652B5031B X VIC-VT7652B5531B X VIC-VT7652B5531E X VIC-VT7652B5531P X VIC-VT7652B5531W X HQR0o0o05f8t0o0p.C U0n11i7t Controller for Modulating Heat VIC-VT7652F5031 X VIC-VT7652F5031B X VIC-VT7652F5531B X VIC-VT7652F5531P X VIC-VT7652F5531W X Heat Pump Controllers VIC-VT7652H5031 X VIC-VT7652H5031B X VIC-VT7652H5531B X VIC-VT7652H5531E X VIC-VT7652H5531P X VIC-VT7652H5531W X Water Source Heat Pump Controller with Humidification Control VIC-VT7652W5031 X VIC-VT7652W5031B X VIC-VT7652W5531B X VIC-VT7652W5531P X VIC-VT7652W5531W X Rooftop Unit Controller with Economizer VIC-VT7656B5031 X X VIC-VT7656B5031B X X VIC-VT7656B5531B X X VIC-VT7656B5531E X X VIC-VT7656B5531P X X VIC-VT7656B5531W X X Indoor Air Quality Controller VIC-VT7656E5031 X VIC-VT7656E5031B X VIC-VT7656E5531B X VIC-VT7656E5531P X VIC-VT7656E5531W X Rooftop Unit Controller with Humidification Control VIC-VT7657B5031 X VIC-VT7657B5031B X VIC-VT7657B5531B X VIC-VT7657B5531E X VIC-VT7657B5531P X VIC-VT7657B5531W X HEAT/COOL 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 1H (analog)/2C 1H (analog)/2C 1H (analog)/2C 1H (analog)/2C 1H (analog)/2C 3H/2C 3H/2C 3H/2C 3H/2C 3H/2C 3H/2C 3H/2C 3H/2C 3H/2C 3H/2C 3H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C 2H/2C HUMIDITY X X X X X X X X X X X PIR COVER COMM. Standalone BACnet MS/TP X BACnet MS/TP X LonWorks X Zigbee Pro X Zigbee Standalone BACnet MS/TP X BACnet MS/TP X Zigbee Pro X Zigbee Standalone BACnet MS/TP X BACnet MS/TP X LonWorks X Zigbee Pro X Zigbee Standalone BACnet MS/TP X BACnet MS/TP X Zigbee Pro X Zigbee Standalone BACnet MS/TP X BACnet MS/TP X LonWorks X Zigbee Pro X Zigbee Standalone BACnet MS/TP X BACnet MS/TP X Zigbee Pro X Zigbee Standalone BACnet MS/TP X BACnet MS/TP X LonWorks X Zigbee Pro X Zigbee 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 222 Setpoint Devices | Room Temperature and Indoor Air Quality Controllers VIC-VT8650 SERIES BACnet MS/TP, and BACnet MS/TP with Zigbee Models Available Commercial and hospitality Suitable for both commercial and hospitality markets and systems Optional humidity sensor Optional humidity sensor with onboard humidification strategy Digital touch screen Customizable color digital touch screen interface with multi-language support Universal inputs and outputs Including CO2 sensor and fresh air station input VIC-VT8650 Smart energy management has never been easier than with the VIC-VT8650 Series Room Temperature and Indoor Air Quality (IAQ) Controller. Designed for new construction and retrofit projects, the temperature and IAC controllers dramatically decrease project delivery costs by reducing installation, configuration and commissioning time. No complex software or tools are required to customize functionality in order to meet your applications requirements. The Room Controllers provide all the advanced features and monitoring functions required by modern building automation systems in a simple compact enclosure. The VIC-VT8650 Room Controllers, part of the VIC-VT8000 family, are both application-specific AND programmable. This enables the modification of pre-configured control sequences, or the creation of entirely new control sequences for HVAC, lighting and other applications. The VIC-VT8650 Room Controllers provide exceptional control of staged heating and cooling equipment such as packaged roof-top units. Their configurable control sequences, economizer and scheduler functionalities deliver all the flexibility necessary for optimal indoor air quality applications.. SPECIFICATIONS Thermostat Power Requirements Operating Conditions Storage Conditions Temperature Sensor Temp. Sensor Resolution Temp. Control Accuracy Humidity Sensor and Calibration Humidity Sensor Precision Humidity Sensor Stability Dehumidification Setpoint Range 24 Vac ±15%, 50/60 Hz, 6 VA 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Local 10k NTC type 2 thermistor ± 0.1 °C (± 0.2 °F) ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical calibrated Single point calibrated bulk polymer sensor Reading range from 10 to 90% RH non-condensing 10 to 20% precision is 10%; 20 to 80% precision is 5%; 80 to 90% precision is 10% <1.0% annual drift (typical) 30 to 95% RH 7-day occupancy scheduling 2 to 4 events Optional cover Optional occupancy sensor cover Wi-Fi option BACnet/IP and email notification via Wi-Fi (with VCM8002V5031) Occupied and Unoccupied Setpoint Range Cooling Occupied and Unoccupied Setpoint Range Heating Room and Outdoor Air Temperature Display Proportional Band for Room Temperature Range Control Binary Inputs Economizer Analog Output Rating Economizer Analog Output Accuracy Wire Gauge WARRANTY Limited Warranty AGENCY APPROVALS 12 to 38 °C (54 to 100 °F) 5 to 32 °C (40 to 90 °F) -40 to 50 °C (-40 to 122 °F) Cooling & Heating: 1.8 °C (3.2 °F ) Dry contact across terminal BI1, BI2 and UI3 to Scom 0 to 10 Vdc into 2k resistance min. ±3% typical 18 gauge maximum, 22 gauge recommended 18 months UL: 61010-1 (2nd edition); CSA: 61010-1 (3rd edition); IEC: 61010-1 (3rd edition), EN 60950-1: 2006A2: 2013, UL 873, CSA 22.2 No. 24-93; 61326-1:2005; FCC: Part 15, Subpart B; CE: EMC Directive 2004/108/EC (European Union); wireless models: FCC Part 15, Subpart C; R&TTE Directive 1999/5/EC; EN: 301 489-1 V1.9.2, 301 328 V1.8.1; RSS 210 223 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Setpoint Devices | VIC-VT8650 Series TYPICAL ROOFTOP UNIT APPLICATION Wiring Examples Air ow direction Optional economizer damper control output Cooling coil Fan Heating coil DIMENSIONAL DRAWING Outdoor air sensor Control Board rn air BACnet MS/TP Wired communication Supply air Supply Air Sensor Zigbee@Pro Optional wireless communication 4.7" (120 mm) 3.4" (86 mm) 1.0" (25 mm) TYPICAL INDOOR AIR QUALITY APPLICATION Wiring Examples Fresh air measurement station Cooling coil Fan Outside air sensor Heating coil Outside air Control Board CO2 air sensor Return air BACnet MS/TP Wired communication Standard wired BACnet MS/TP communication and optional ZigBee Pro communication module upgrade SELECTABLE COLOR SCHEMES Supply air Supply air sensor Zigbee@Pro Optional wireless communication Optional Wireless Accessories Base Connecting Thermostat Zigbee Pro Communication Module Water Leak Wireless Sensor CO2 Wireless Module Door/Window WirelessSensor Wall/Ceiling Wireless Sensor Wi-Fi Module ORDERING INFORMATION PART # VIC-VT8650U5000B VIC-VT8650U5500B VIC-VT8650U5500BP DESCRIPTION Fancoil Control, Low Voltage, RH, BACnet MS/TP Fancoil Control, Low Voltage, RH, PIR, BACnet MS/TP RH, PIR Room Controller, BACnet MS/TP and Zigbee 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 233 224 Setpoint Devices | Fancoil Unit Thermostat Retrofit Solution VIC-VTR835X0A5X SERIES/ VIC-VC3XXXE5000 Network Ready, BACnet MS/TP, and Wireless Models Available Commercial and hospitality Suitable for both commercial and hospitality markets and systems (VTR8300 Series) Extremely compact design (VC3000 Series) Digital touch screen Customizable color digital touch screen interface with multi-language support (VTR8300 Series) 90 to 277 Vac Line powered from 90 to 277 Vac, 50 to 60 Hz (VC3000 Series) VIC-VTR835x0A5x VIC-VC3xxxE5000 7-day occupancy scheduling 2 to 4 events (VTR8300 Series) Wire-leads Wire-leads for line-voltage connections (VC3000 Series) This two component retrofit option consists of the VTR8300 terminal equipment controller and the VC3000 relay pack. Together, they provide an easy solution for retrofitting fan coil unit thermostats without requiring upgrades to other components such as relays, transformers, controllers, sensors, and network wiring. Existing line voltage wiring between the fan coil unit and temperature controller can be reused, further minimizing overall labor and installation costs. The VC3000 relay pack features an onboard universal voltage power supply and line-voltage relays that directly drive fractional horsepower fan motors and valves. The VTR8350 controller features a fully digital multi-language touch screen display that can be user customized. The controller's built-in commissioning and configuration utility, its temperature sensor, and the optional humidity and occupancy sensor, provide maximum flexibility. The VTR8350 controller is available in Network Ready, BACnet® MS/TP or wireless Zigbee networked models. SPECIFICATIONS Thermostat Power Requirements Operating Conditions Storage Conditions Temperature Sensor Temp. Sensor Resolution Temp. Control Accuracy Humidity Sensor and Calibration Humidity Sensor Precision 7 Vdc, 2.4 W min. (from VC3000) 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Local 10k NTC type 2 thermistor ± 0.1 °C (± 0.2 °F) ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical calibrated Single point calibrated bulk polymer sensor Reading range from 10 to 90% RH noncondensing 10 to 20% precision is 10%; 20 to 80% precision is 5%; 80 to 90% precision is 10% Wi-Fi option BACnet/IP and email notification via Wi-Fi (with VCM8002V5031) Humidity Sensor Stability Dehumidification Setpoint Range Occupied and Unoccupied Setpoint Range Cooling Occupied and Unoccupied Setpoint Range Heating Room and Outdoor Air Temperature Display Proportional Band for Room Temperature Range Control Binary Inputs Economizer Analog Output Rating Economizer Analog Output Accuracy Wire Gauge WARRANTY Limited Warranty AGENCY APPROVALS <1.0% annual drift (typical) 30 to 95% RH 12 to 38 °C (54 to 100 °F) 5 to 32 °C (40 to 90 °F) -40 to 50 °C (-40 to 122 °F) Cooling & Heating: 1.8 °C (3.2 °F ) Dry contact across terminal BI1, BI2 & UI3 to Scom 0 to 10 Vdc into 2k resistance min. ±3% typical 18 gauge maximum, 22 gauge recommended 18 months UL: 61010-1 (2nd edition); CSA: 61010-1 (3rd edition); IEC: 61010-1 (3rd edition), EN 60950-1: 2006A2: 2013, UL 873, CSA 22.2 No. 24-93; 61326-1:2005; FCC: Part 15, Subpart B; CE: EMC Directive 2004/108/EC (European Union); wireless models: FCC Part 15, Subpart C; R&TTE Directive 1999/5/EC; EN: 301 489-1 V1.9.2, 301 328 V1.8.1; RSS 210 225 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Setpoint Devices | VIC-VTR83x0A5x Series/ VIC-VC3xxxE5000 WALL CONTROLLERS Ordering Information PART # VIC-VTR8350A5000B VIC-VTR8350A5500B VIC-VTR8350A5500BP DESCRIPTION Fancoil Terminal Equipment Controller, PIR ready (PIR cover not included), onboard humidity sensor Fancoil Terminal Equipment Controller, PIR factory equipped, onboard humidity sensor COMM. BACnet BACnet Wireless (Zigbee Pro) RELAY PACKS Ordering Information PART # VIC-VC3500E5000 VIC-VC3504E5000 VIC-VC3404E5000 VIC-VC3300E5000 DESCRIPTION Transformer relay pack, 5 relay fan outputs Transformer relay pack, 5 relay fan outputs and 4 outputs Transformer relay pack, 4 relay fan outputs, smart Vdc output, and 4 inputs Transformer relay pack, 3 slave fan outputs WIRING EXAMPLES Filter 3-Speed Fan Cooling Coil Heating Coil lter status switch fan status switch APPLICATIONS DIMENSIONAL DRAWING Wall Control and Relay Pack Applications (BACnet models shown, wireless similar) APPLICATION 2 or 4 pipe, up to 3 speed fan, humidity control 2 pipe, up to 3 speed fan 2 or 4 pipe, up to 3 speed fan, humidity control 2 pipe, up to 3 speed fan Slave fan control only OUTPUTS/ INPUTS CONTROLLER PART # RELAY PACK PART # 1H/1C with reheat VIC-VTR8350A5000B VIC-VC3500E5000 1H/1C with 4 inputs and reheat VIC-VTR8350A5000B VIC-VC3504E5000 1H/1C with 4 inputs, reheat, and occ. output VIC-VTR8350A5000B - 1H/1C with pulsed reheat - VIC-VC3500E5000 1H/1C with 4 inputs and - pulsed reheat VIC-VC3504E5000 1H/1C with reheat VIC-VTR8350A5000B VIC-VC3500E5000 1H/1C with 4 inputs and reheat VIC-VTR8350A5000B VIC-VC3504E5000 1H/1C with 4 inputs, reheat, and occ. output VIC-VTR8350A5000B - 1H/1C with pulsed reheat - VIC-VC3500E5000 1H/1C with 4 inputs and - pulsed reheat VIC-VC3504E5000 3 fan outputs - VIC-VC3300E5000 4.7" (120 mm) 3.4" (86 mm) SELECTABLE COLOR SCHEMES VIC-VC3504E5000 VIC-VTR8300 1.0" (25 mm) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 233 226 Setpoint Devices | Communicating Humidistat Series VIC-VH7200 SERIES BACnet, Echelon, and Wireless Models Available VIC-VH7200A1000 PI time proportioning PI time proportioning algorithm for increased comfort, accuracy, and energy savings Lockable keypad Tamper resistant, no need for thermostat guards Binary input Binary input for added functionality EEPROM memory No loss of program Local configuration Unique local configuration utility...minimizes parameter tampering Optional remote humidity sensors Increased flexibility and functionality The VIC-VH7200 humidity controller family features a complete embedded humidity control solution with an intuitive backlit LCD display that walks the installer through the configuration steps, making the process extremely simple. Accurate relative humidity control is achieved via the product's unique PI time proportional control algorithm, which virtually eliminates humidity offset associated with traditional, differential-based humidity controllers. All models contain a user-controlled binary input, which monitors an electrode humidifier canister service status or may be used as a general purpose service indicator. Models are available with more advanced features such as discharge humidity, proportional high limit, and indoor humidity setpoint reset based upon outdoor air temperature. SPECIFICATIONS Humidistat Power Requirements 19 to 30 Vac; 50 or 60 Hz; 2 VA (RC & C) Class 2 Operating Conditions 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing Storage Conditions -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Resolution: Temp Humidity ±0.1 °C (±0.2 °F) ±0.1% Control Accuracy Humidity ±3% RH from 20 to 70% RH at 21 °C (70 °F) Humidification Setpoint Range 10 to 90% RH Dehumidification Setpoint 15 to 95% RH Range Outdoor Air Temp Range -40 to 50 °C (-40 to 122 °F) APPLICATIONS · Humidifier · Dehumidifier/air exchanger · Humidity high limit sensor · Outdoor air temperature sensor · Airflow switch Binary Inputs Contact Output Rating Analog Output Rating Wire Gauge Dimensions Approximate Shipping Weight WARRANTY Limited Warranty AGENCY APPROVALS Relay dry contact only across Scom and DI1 terminals Each relay output: 30 Vac, 1A max.; 30 Vac, 3 A in-rush 0 to 10 Vdc into 2k resistance min. 18 gauge maximum, 22 gauge recommended 4.94" x 3.38" x 1.13" (12.5 x 86 x 30 mm) 0.75 lb (0.34 kg) 2 years UL: 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN , XAPX (US) and XAPX7 (Canada) FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US) Industry Canada: ICES-003 (Canada) CE: EMC Directive 2004/108/EC (European Union) 227 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Setpoint Devices | VIC-VH7200 Series WIRING EXAMPLE R.A. Humidi cation Output: (On/O ) or (0 to 10 Vdc) Refer to parameter "SeqOpera: S.A. VH7270K1000 Humidity Controller Flow (On/O ) Humidi er Switch HH Dry Contact (0 to 10 Vdc) Humidi er 0 to 10 24 V Com X X Flow Switch HUM HUM R C DEH DEH Dry Contact Dehumidi cation and/or air exchanger HUM 0-10 DI1 HS Scom OS HL S2020E1000 or S2000D1000 Optional Outdoor Temperature Sensor Binary Input"Di1" Set for"Service"alarm ORDERING INFORMATION PART # VIC-VH7200A1000 VIC-VH7270F1000 VIC-VH7270K1000 DESCRIPTION Humidistat, ON/OFF Humidistat, Analog Outputs Humidistat, Analog Outputs, ON/OFF DIMENSIONAL DRAWING 4.9" (125 mm) 1.25" (32 mm) 3.4" (87 mm) 1.1" (28 mm) 1.5" (37 mm) 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 233 228 Setpoint Devices | Zone Terminal Equipment Controller VZ7000 SERIES BACnet MS/TP, LonWorks, Zigbee and Zigbee Pro Models Available PI time proportioning PI time proportioning algorithm for increased comfort, accuracy, and energy savings Local configuration Unique local configuration utility minimizes parameter tampering Three digital inputs Three digital inputs for added functionality Occupancy sensor Models with occupancy sensor available Analog input One 0-10V input for added functionality Lockable keypad Tamper resistant, no need for thermostat guards The VZ commercial zoning system has been specifically designed to bring a simple scalable solution to mid-market commercial applications without the cost associated with a typical DDC zoning system. Models include Rooftop and heat pump units controlling analog heat, CO2 levels, and indoor air quality. Zoning controllers that provide floating and analog damper control are also available. A single central Controller unit can support up to 32 individual zone controllers. All zoning system controllers can be fitted with an on-board PIR occupancy sensor cover that allows for advanced occupancy strategies, enabling greater energy savings to zones during scheduled events when no occupants are present. APPLICATIONS · Rooftop zoning unit controller · Rooftop zoning master controller · Heat pump zoning controller SPECIFICATIONS Thermostat Power Requirements Operating Conditions Storage Conditions Temperature Sensor Resolution Control Accuracy Occupied and Unoccupied Setpoint Range Cooling Occupied and Unoccupied Setpoint Range Heating Room and Outdoor Air Temperature Display Proportional Band for Room Temperature Range Control Analog Input Binary Inputs Output Rating 19 to 30 Vac; 50 or 60 Hz; 2 VA Class 2 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Local 10k NTC thermistor ± 0.1 °C (± 0.2 °F) Temp: ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical calibrated 12 to 37.5 °C (54 to 100 °F) 4.5 to 32 °C (40 to 90 °F) -40 to 50 °C (-40 to 122 °F) Cooling & Heating: 1.8 °C (3.2 °F ) AI4 0-10 Vdc into 10 k resistance min. Dry contact across BI1, BI2 and UI3 to common 30 Vac, 1 A max., 3 A in-rush Economizer Analog Output Rating Economizer Analog Output Accuracy Wire Gauge Dimensions Approximate Shipping Weight WARRANTY Limited Warranty AGENCY APPROVALS 0 to 10 Vdc into 2k resistance min. ±3% typical 18 gauge maximum, 22 gauge recommended 4.94" x 3.38" x 1.13" (12.5 x 86 x 30 mm) 0.75 lb (0.34 kg) 2 years UL: 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN , XAPX (US) and XAPX7 (Canada) FCC: Compliant to CFR 47, Part 15, Subpart B (US) Industry Canada: ICES-003 (Canada) CE: EMC Directive 89/336 EEC (European Union). C-Tick: AS/NZS CISPR 22 Compliant (Australia / New Zealand); Supplier Code Number N10696 Wireless models: FCC compliant to Part 15, Subpart C CE: R and RTTE Directive 1995/5/EC (European Union) 229 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING Setpoint Devices | VZ7000 Series 4.9" (125 mm) 1.25" (32 mm) 3.4" (87 mm) 1.1" (28 mm) 1.5" (37 mm) ORDERING INFORMATION PART NUMBER Rooftop Unit Controllers DESCRIPTION VIC-VZ7260C5031B VIC-VZ7260C5031W VIC-VZ7260F5031B VIC-VZ7260F5031W Zone Control 2x Floating - Variable Volume Temp (VVT) Zone Zone Control 2x Floating - Variable Volume Temp (VVT) Zone Zone Control 2x Analog - Variable Volume Temp (VVT) Zone Zone Control 2x Analog - Variable Volume Temp (VVT) Zone OUTPUT COMM. Floating or On/Off Floating or On/Off 0-10V 0-10V BACnet MS/TP Zigbee BACnet MS/TP Zigbee PART NUMBER HEAT/COOL IAQ Commercial Zoning System - Rooftop Master Controllers VIC-VZ7656E1031B 2H/2C X VIC-VZ7656E1031W 2H/2C X VIC-VZ7656F1031B 1H/2C VIC-VZ7656F1031W 1H/2C VIC-VZ7656H1031B 2H/2C VIC-VZ7656H1031W 2H/2C ECONOMIZER X X MOD. HEAT COMM. BACnet MS/TP Zigbee X BACnet MS/TP X Zigbee BACnet MS/TP Zigbee PART NUMBER DESCRIPTION Commercial Zoning System - Heat Pump Controllers VIC-VZ7656R1031B Zone System Control Heat Pump - VariableVolume & Temperature (VVT) Master VIC-VZ7656R1031W Zone System Control Heat Pump - VariableVolume & Temperature (VVT) Master COMM. BACnet MS/TP Zigbee 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 233 230 Setpoint Devices | Variable Air Volume (VAV) Unit Controllers VZ8250 SERIES BACnet MS/TP, and BACnet MS/TP with Zigbee Pro Models Available Commercial and hospitality Suitable for both commercial and hospitality markets and systems 7-day occupancy scheduling 2 to 4 events Digital touch screen Customizable color digital touch screen interface with multi-language support Universal inputs and outputs Including CO2 sensor and fresh air station input VZ8250 Smart energy management has never been easier than with the VZ8250 Room Controllers for Variable Air Volume (VAV) applications. Designed for new construction and retrofit projects, the Room Controllers dramatically decrease project delivery costs by reducing installation, configuration and commissioning time. No complex software or tools are required to customize functionality to meet your applications requirements. The Room Controllers provide all the advanced features and monitoring functions required by modern building automation systems in a simple compact enclosure. The VZ8250 Room Controllers, part of the VT8000 family, are both application-specific AND programmable. This enables the modification of pre-configured control sequences, or the creation of entirely new control sequences for VAV applications. Their configurable control sequences and scheduler functionalities deliver all the flexibility necessary for optimal indoor air quality applications. Humidity sensor Humidity sensor with onboard humidification strategy APPLICATIONS · Single-speed fans · Outdoor air temperature sensor Optional cover Optional occupancy sensor cover · Supply air temperature sensor · Differential pressure switch SPECIFICATIONS Thermostat Power Requirements Operating Conditions Storage Conditions Temperature Sensor Temp. Sensor Resolution Temp. Control Accuracy Humidity Sensor Precision Humidity Sensor Stability Occupied and Unoccupied Setpoint Range Cooling Occupied and Unoccupied Setpoint Range Heating Room and Outdoor Air Temperature Display 24 Vac ±15%, 50/60 Hz, 6 VA or 24 Vdc ± 15% 0 to 50 °C (32 to 122 °F); 0 to 95% RH non-condensing -30 to 50 °C (-22 to 122 °F); 0 to 95% RH non-condensing Local 10k NTC type 2 thermistor ± 0.1 °C (± 0.2 °F) ±0.5 °C (±0.9 °F ) @ 21 °C (70 °F) typical calibrated Reading range from 10 to 90% RH non-condensing 10 to 20% precision is 10%; 20 to 80% precision is 5%; 80 to 90% precision is 10% <0.25% annual drift (typical) 12 to 37.5 °C (54 to 100 °F) 4.5 to 32 °C (40 to 90 °F) -40 to 50 °C (-40 to 122 °F) Proportional Band for Room Temperature Range Control Analog Inputs Binary Inputs Remote Temperature Sensor Wire Gauge WARRANTY Limited Warranty AGENCY APPROVALS Cooling & Heating: 1.8 °C (3.2 °F ) Modulating 0-10 Vdc across UI18, UI24 to common Dry contact across terminal UI16, UI17 to common 10K T2 thermistor UI20, UI22, UI23 18 gauge maximum, 22 gauge recommended 18 months UL: UL 60730-1, UL 60730-2-9, UL 60730-2-13 CAN/CSA: E60730-1, E60730-2-9 CE: EN 60730-1, EN 60730-2-9, EN 60730-2-13 Models with Zigbee Radio RED 2014/53/EU ETSI: EN 300 328, EN 301 489-1, EN 301 489-17 FCC Part 15C RSS-247 231 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com HQ0001872.F 0117 Setpoint Devices | VZ8250 Series TYPICAL PRESSURE INDEPENDENT APPLICATION (NO FAN) Wiring Example Flow sensor Damper Reheat Supply air DIMENSIONAL DRAWING DP sensor Changeover sensor Actuator sensor BACnet MS/TP Wired communication protocol Zigbee Pro Optional wireless sensors BACnet IP Optional wireless communication Baseboards TYPICAL PRESSURE INDEPENDENT APPLICATION (PARALLEL FAN) Wiring Example 4.7" (120 mm) 3.4" (86 mm) 1.0" (25 mm) SELECTABLE COLOR SCHEMES Flow sensor Damper Parallel fan Reheat Supply air DP sensor sensor Actuator Supply air sensor BACnet MS/TP Wired communication protocol Zigbee Pro Optional wireless sensors BACnet IP Optional wireless communication Baseboards TYPICAL PRESSURE DEPENDENT APPLICATION (NO FAN) Wiring Example Damper Reheat Supply air ORDERING INFORMATION PART NUMBER VIC-VZ8250U5000B VIC-VZ8250U5500B VIC-VZ8250U5500BP DESCRIPTION COMM. BACnet MS/TP BACnet MS/TP WRLS Changeover sensor Actuator Supply air sensor BACnet MS/TP Wired communication protocol Zigbee Pro Optional wireless sensors BACnet IP Optional wireless communication Baseboards HQ0001872.F 0117 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 233 232 Setpoint Devices | Accessories ACCESSORIES: SETPOINT DEVICES BMS WIRELESS INTEGRATION The GW2 Wireless Gateway Manager and Zigbee Pro VT7000/VT8000 Room Controllers are targeted for either retrofit or new construction applications where the addition of communicating field bus wiring within the building space is prohibitive. The GW2 and Communicating Room Controllers with a wireless field bus encourages the use of existing wiring utilized by existing electronic controller type controls. WIRELESS GATEWAY The GW2, when utilized in conjunction with the Room Controllers, will offer the integrator simple BACnet IP objects to integrate over standard building automation systems using familiar integration toolsets. A maximum of 30 Room Controllers can be wirelessly attached to a single GW2. PART NUMBER DESCRIPTION VIC-GW2-0I0-00 Wireless gateway COMMUNICATION AND SENSORS VT8000 Room Controllers can be adapted to communicate via one of three VCM modules: Wireless Zigbee Pro extended profile, CO2 detection sensor, or Wi-Fi extended profile. This allows the VT8000 to pair with a variety of wireless sensors and switches for more precise control of HVAC systems in response to occupancy, as well as to communicate wirelessly for integration with BMS and networks. PART NUMBER DESCRIPTION VIC-VCM8000V5045P Wireless Zigbee Pro communication card VIC-VCM8001V5045 CO2 sensor module VIC-VCM8002V5031 Wi-Fi module COMPATIBILITY VT8000 Room Controllers VT8000 Room Controllers VT8000 Room Controllers VIC-GW2-0I0-00 VIC-VCM8000V5045P VIC-VCM8001V5045 VIC-VCM8002V5031 233 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Setpoint Devices | Accessories COMMUNICATION ADAPTERS VT7000 Room Controllers are network ready, designed to accept the addition of communication. With a network card available for field upgrade, your system can be networked to an integrated building management system for the most advanced control and functionality. In the part numbers, please note that: · W: Legacy Zigbee for replacement · P: Zigbee Pro, compatible with all room controllers PART NUMBER VIC-VCM7000V5000W DESCRIPTION COMPATIBILITY Wireless Communication Card - 7000 - Zigbee Pro extended profile retrofit communication module 7000 Series Room Controllers (72, 73, R73, and 76) VIC-VCM7000V5000P VIC-VCM7260Z5000B VIC-VCM7260Z5000W VIC-VCM7300T5000B VIC-VCM7300T5000E VIC-VCM7300V5000B VIC-VCM7300V5000E VIC-VCM7600W5000B VIC-VCM7600W5000W VIC-VCM7600V5000B VIC-VCM7600V5000E VIC-VCM7607V5000B VIC-VCM7607V5000E VIC-VCM7656Z5000B VIC-VCM7656Z5000W Wireless Communication Card - 7000 - Zigbee proprietary wireless retrofit communication module BACnet replacement communication module Zigbee replacement communication module Communication Module BACnet 73 with Relay Module - BACnet retrofit communication module Communication Module LON 73 with Relay Module - Echelon retrofit communication module BACnet Communication Card - 7200/7300 - BACnet retrofit communication module LON Communication Card - 7200/7300 - Echelon retrofit communication module BACnet retrofit communication module Zigbee proprietary wireless retrofit communication module BACnet Communication Card - BACnet retrofit communication module LON Communication Card - Echelon retrofit communication module BACnet Communication Card - 76X7 -BACnet retrofit communication module LON Communication Card - Echelon retrofit communication module BACnet replacement communication module Zigbee replacement communication module 7000 Series Room Controllers (72, 73, R73, 76xx(B,H) and 76x7(B)) 7260(C,F) 7260(C,F) R73xx(A) R73xx(A) 7200(C,F) and 73xx(C,F) 7200(C,F) and 73xx(C,F) 76xx(W,E,F) 76xx(W,E,F) 76xx(B,H) 76xx(B,H) 76x7(B) 76x7(B) Z7656(E,F,R,H) Z7656(E,F,R,H) Note: The VCM7607V5000E (terminal equipment Controller Echelon LonTalk communication adapter) is not available for: VT7600W, VT7600F Room Controller models. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 234 CURRENT MONITORING The Hawkeye line of current sensors is widely known as the industry standard for proof of flow. Unlike mechanical switches, Hawkeye current sensors are solid-state, minimizing failures caused by the wear and tear of moving parts. Veris offers a full range of analog and digital current sensing devices. MODEL H300/600/800/800NC/800HV/900 H308/608/701/708/808/908 H609/709/709HV/809/909/909HV H606/706/806/906 H11D H614 H720/904/934 H6ECM H730/740/750/930/940/950 H735/738/748/758/938/948/958 H739/749/939/949/959 H721HC/721LC/921 H221/221SP/321/321SP/421/421SP H722LC/722HC/822/822-20/922 H723LC/723HC/923 H931 H932/952 H971/971SP/EA20 Series H5xx Series H120/120NC DESCRIPTION Current Switches: Fixed Trip Point (Status) Current Switches: Adjustable Trip Point, Standard Output Current Switches: Adjustable Trip Point, High Voltage Output Current Switches: Adjustable Trip Point, N.C. Output Current Switches: Auto Calibration, Automation Systems, LCD Display VFD Current Switch: Auto Calibration VFD Switches and Current Sensors ECM-Optimized Current Switch Current Switches with Relay: Fixed Trip Point (Status) Current Switches with Relay: Adjustable Trip Point, Standard Output Current Switches with Relay: Adjustable Trip Point, High Voltage Output Current Transducers: 4 to 20 mA Analog Output Current Transducers: 4 to 20 mA Analog Output, High Current Monitoring Current Transducers: 0 to 5 Vdc Analog Output Current Transducers: 0 to 10 Vdc Analog Output Current Transducers with Relay: 4 to 20 mA Analog Output Current Transducers with Relay: 0 to 5 Vdc Analog Output Direct Current Transducers: 4 to 20 mA and 0 to 5 Vdc Analog Output Field Mount Motor Control Device Field Mount Status Relay PAGE 239 241 243 245 247 249 251 253 255 257 259 261 263 265 267 269 271 273 275 277 235 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com CURRENT SENSOR SELECTION GUIDE CURRENT STATUS SWITCHES (DIGITAL OUTPUT) APPLICATIONS MICRO SPLIT-CORE (BEST ON RETROFITS) MINI SOLID-CORE (COST EFFECTIVE FOR NEW INSTALLATIONS) Detect Status (Digital On/Off) H300 -- 60A page 239 H800* -- 200A page 239 Detect Belt Loss and Mechanical Failure (Adjustable Threshold) H308 -- 50A page 241 H808 -- 50A page 241 H806 -- 50A page 245 H809 -- 50A page 243 Self-Calibrating Switch VFD Model - Patented Technology VFD Model - Patented Technology (Onboard Relay) Veris Exclusive Patented Technology Status & Control (Onboard Pilot Duty Relay) MINI SPLIT-CORE (BEST ON RETROFITS) H600 -- 200A page 239 H608 -- 175A page 241 H606 -- 50A page 245 H609 -- 50A page 243 H614 -- 150A page 249 STANDARD SOLID CORE (COST EFFECTIVE FOR NEW INSTALLATIONS) H708 -- 135A page 241 H706 -- 135A page 245 H709* -- 135A page 243 H730* -- 200A page 255 H738* -- 135A page 257 H739* -- 135A page 259 STANDARD SPLIT-CORE (BEST ON RETROFITS) H900 -- 200A page 239 H908 - 135A page 241 H906 - 135A page 245 H909* - 135A page 243 H11D -- 200A page 247 H904 -- 135A/20-75Hz page 251 H6ECM -- 0.5 - 175A page 253 H934 -- 135A/20-75Hz page 251 H930* -- 200A page 255 H938* -- 135A page 257 H939* -- 135A page 259 FLYING LEADS AND JUNCTION BOX MOUNTING High Voltage/Low Voltage Split Power Duty Status and Control * Indicates a series of products. H120* -- to 20A/2HP page 277 H5xx* -- to 15A/1.5HP page 275 CURRENT TRANSDUCERS (Analog Output) 10A MONITOR CURRENT LEVEL 2400A APPLICATIONS Load Trending 4-20mA Output Load Trending 0-5V Output Load Trending 0-10V Output Load Trending with Relay 4-20mA Output Load Trending with Relay 0-5V Output DC Current 4-20mA Output VFD 4-20mA Output * Indicates a series of products. H822*: 10/20A page 265 H721LC: 10-40A page 261 H722LC: 10-40A page 265 H723LC: 10-40A page 267 H921: 30-120A page 261 H922*: 30-120A page 265 H923: 20-150A page 267 H931: 30-120A page 269 H932/H952: 30-120A page 271 H721HC: 50-200A page 261 H722HC: 50-200A page 265 H723HC: 50-200A page 267 H971/EA20: 10-200A page 273 H720: 0-200A page 251 H221/321/421: 300/800/2400A page 263 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 236 ADAPTABLE, VIEWABLE, AND COST COMPETITIVE H11D Current Switch APPLICATIONS » HVAC fans, pumps, and blowers » Monitoring status of industrial process equipment FEATURES ELIMINATE GUESSWORK View real-time amperage in the conductor, and know the exact trip current limits ADJUST TO AN APPLICATION ON THE FLY Slide-switch selectable normal, wide range, and on/off trip points EXCEPTIONAL LABOR SAVINGS Self-calibrating, self-learning: snap on and complete 237 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ULTIMATE VFD FAN AND PUMP STATUS H614 VFD Current Switch APPLICATIONS » Monitoring fans, pumps, motors, and other electrical loads for proper operation » Detecting belt loss and motor failure ideal for fan and pump status » Verifying lighting circuit loads » Monitoring critical motors (compressor, fuel, etc.) » Monitoring industrial process equipment status (OEM) FEATURES GREATER INTELLIGENCE Industry's most reliable self-learning, self-calibrating current switch INCREASED KNOWLEDGE 12-115 Hz, providing the industry's largest monitoring range SIMPLIFIED INSTALLATION Auto configures up to 20 trip points for fault detection on VFD fan/pump motors 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 223388 Current Monitoring | Current Switches: Fixed Trip Point HX00 SERIES On/Off Status Current Switches H800 H900 Maximize Reliability Minimize Installed Cost H300 H600 Reliable More reliable for status than relays across auxiliary contacts Installation flexibility Removable mounting bracket provides installation flexibility Ideal for directdrive units Ideal for direct-drive units, unit vents, fan coil units, exhaust fans, and other fixed loads Flexibility Bracket on H900 can be installed in three different configurations Low setpoint Minimum trip point as low as 0.5 A (H608)...avoids the need for multiple wraps of the conductor through the sensor even on loads as small as 1/5 HP Quick installation Split-core H300, H600 and H900 for fast retrofit installation Hawkeye x00 on/off current switches provide a cost-effective solution for monitoring status on unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern. Veris has applied new technology to the H300, H600, and H800 models to achieve impressive improvement in turn-on levels. The Hawkeye H300 and H600 have the lowest turn-on current in the industry at a mere 0.15 A! APPLICATIONS · Electrical load status · VFD output On/Off status · Direct-drive units, exhaust fans, process motors, and other fixed loads · Direct-Drive units, unit vents, fan coil units, exhaust fans, and other fixed loads · Lighting run times and status SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range: H800NC, H300, H900 H600 H800, H800HV Humidity Range Off State Leakage (H800NC Only) On State Voltage Drop (H800NC Only) N.O models: Induced from monitored current; H800NC: 5 to 30 Vdc, permanently connected 600 Vac RMS (UL), 300 Vac RMS (CE) 50/60 Hz, On/Off status for Variable Frequency Drive (VFD) outputs at 12 to 115 Hz (a) -15 to 60 °C (5 to 140 °F) -15 to 40 °C (5 to 104 °F) (to 200 A); -15 to 60 °C (5 to 140 °F) (to 150 A) -40 to 50 °C (-40 to 122 °F) (to 200 A); -40 to 75 °C (-40 to 167 °F) (to 100 A, and 0.25 A status output) 10 to 90% RH non-condensing 34 A @ 5 Vdc, 200 A @ 30 Vdc 1.9 Vdc (max.) @ 0.1 A Terminal Block Wire Size H600, H800, H900 H300 Terminal Block Torque H600, H800, H900 H300 WARRANTY Limited Warranty AGENCY APPROVALS Agency approvals 24 to 14 AWG (0.2 to 2.1 mm2); 22 to 16 AWG (0.3 to 1.3 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m); 7 in-lbs (0.8 N-m) 5 years UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation E150462 Note: Do not use the LED status indicators as evidence of applied voltage. (a) VFD systems generate fields that can disrupt electrical devices. Ensure that these fields are minimized and are not affecting the sensor. 239 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | Hx00 Series H300 Dimensional Drawing H600 Dimensional Drawing UNIT VENT HEATER CONTROL Wiring Diagram Removable Mounting Bracket Self-gripping Iris Removable Mounting Bracket 0.3" (8 mm) 6 AWG max. 1.6" (40 mm) 2.1" (54 mm) 0.6" (16 mm) 1.2" 0.7" (31 mm) (18 mm) 0.5" (13 mm) 2.5" * (64 mm) POWER SOURCE BUILDING AUTOMATION CONTROLLER Digital Input Digital Input Ø 0.18" (x2) (5 mm) 1.5" (38 mm) 0.4" x 0.2" (10 mm x 5 mm) Slot (2x) 2.1" (54 mm) Self-gripping Iris 1.8" (46 mm) 0.6" (15 mm) 2.9" (74 mm) 3.5" (89 mm) 1.0" (26 mm) POWER SOURCE UNIT VENT HEATER H800, H800HV, H800NC Dimensional Drawing H900 Dimensional Drawing Removable/Adjustable Mounting Bracket Removable Mounting Bracket 0.7" (18 mm) 0.9" (23 mm) 1.1" (26 mm) 3.1"** 2.8" * (79 mm) (71 mm) 1.0" (25 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris 0.4" x 0.2" Slot (x2) 1.7 (43 mm) 1.1" * (27 mm) Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" 3.0" (64 mm) (76 mm) 1.4"* (36 mm) 2.3" (58 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. ORDERING INFORMATION MODEL AMPERAGE RANGE @ 50/60 HZ ONLY STATUS OUTPUT (MAX.) TRIP POINT HOUSING UL H300 0.15 to 60 A N.O. 1.0 A @ 30 Vac/dc 0.15 A or less Split-core · 2 H600 0.15 to 200 A N.O. 1.0 A @ 30 Vac/dc 0.15 A or less Split-core · 1 H800 0.25 to 200 A N.O. 1.0 A @ 30 Vac/dc 0.25 A or less Solid-core · 1 H800NC 0.5 to 200 A N.C. 0.1 A @ 30 Vdc 0.5 A or less Solid-core · 1 H800HV 0.75 to 200 A N.O. 0.5 A @ 250 Vac/dc 0.75 A or less Solid-core · 3 H900 1.5 to 200 A N.O. 1.0 A @ 30 Vac/dc 1.5 A or less Split-core · CE LEAD FREE 1. Listed for use on 75°C insulated conductors. 2. Product provides functional · insulation only. · 3. Listed for use on 90°C insulated conductors. · · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 240 Current Monitoring | Current Switches: Adjustable Trip Point, Standard Output HX08 SERIES & H701 Detect Belt Loss, Coupling Shear, and Mechanical Failure Retrofit or new construction High performance devices in splitand solid-core housings Small size Fits easily inside small enclosures H908 H708 H608 H808 Maximize Reliability Minimize Installed Cost H308 Hx08 Series and H701 adjustable current switches offer high performance, with a wide array of amperage range options. These products can accurately detect belt loss, coupling shear, or other mechanical failure on unit vents, exhaust fans, recirculation pumps, and other fixed loads down to as little as 1/5 HP. Adjustable trip point Precise current trip point setting Self-gripping iris Self-gripping iris on split-core housings for easy installation Low setpoint Status LEDs Minimum trip point as low as 0.5 A (H608)...no need for multiple wraps of the conductor through the sensor, even on loads as small as 1/5 HP Status LEDs available for easy setup and local indication APPLICATIONS · Detecting belt loss, coupling shear, and mechanical failure · Verifying lighting circuit and other electrical service run times · Monitoring status of industrial process equipment · Monitoring status of critical motors (compressor, fuel, etc.) · VFD output on/off status SPECIFICATIONS Sensor Power Insulation Class Frequency Range 2 Temperature Range Humidity Range Hysteresis Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Induced from monitored conductor 600 Vac RMS (UL), 300VAC RMS (CE) 50/60 Hz, On/Off status for Variable Frequency Drive (VFD) outputs at 12 to 115 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing 10% (typical) H308: 22-16 AWG (0.3 to 1.3 mm2) Others: 24-14 AWG (0.2 to 2.1 mm2) H308: 3.5 to 7 in-lbs (0.8 N-m) Others: 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation E150462 DETECTS BELT LOSS/COUPLING SHEAR! Calibrated Trip Point Fan/pump On Electrical Failure O Loss of Belt/Coupling Shear O Now you can easily detect when drive belts slip, break, or pump couplings shear. In fact, a typical HVAC motor that loses its load has a reduction of current draw of up to 50%. That's why our sensors are the industry standard for status. Notes: Do not use the LED status indicators as evidence of applied voltage. If using this switch in an application that includes an electronically commutated motor (ECM), see Veris Application Note VN61, at www.veris.com. VFD systems generate fields that can disrupt electrical devices. Ensure that these fields are minimized and are not affecting the sensor. 241 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | Hx08 Series & H701 H308 Dimensional Drawing Removable Mounting Bracket Self-gripping Iris 0.3" (8 mm) 6 AWG max. 1.6" (40 mm) Ø 0.18" (x2) (5 mm) 1.5" (38 mm) 1.8" (46 mm) 0.6" (15 mm) H608 Dimensional Drawing Removable Mounting Bracket MONITORING FAN /PUMP MOTORS FOR POSITIVE PROOF OF FLOW Wiring Diagram 2.1" (54 mm) 0.6" (16 mm) 1.2" 0.7" (31 mm) (18 mm) 0.5" (13 mm) 2.5" * (64 mm) 0.4" x 0.2" (10 mm x 5 mm) Slot (2x) 2.1" (54 mm) Self-gripping Iris CONTACTOR 9 CONTROLLER Digital Input 1.0" (26 mm) Fan or Pump 2.9" (74 mm) 3.5" (89 mm) Motor H708/701 Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) H908 Dimensional Drawing H808 Dimensional Drawing Removable Mounting Bracket 1.0" (25 mm) 1.1" (26 mm) 3.1"** (79 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Removable/Adjustable Mounting Bracket 0.7" (18 mm) 0.9" (23 mm) 2.8" * (71 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) 1.1" * (27 mm) Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" (64 mm) 3.0" (76 mm) 1.4"* (36 mm) 0.4" x 0.2" Slot (x2) 1.7 (43 mm) 1.1" * (27 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. 2.3" (58 mm) ORDERING INFORMATION MODEL AMPERAGE RANGE @ 50/60 HZ ONLY STATUS OUTPUT (MAX.) MIN. TRIP POINT HOUSING STATUS LED UL CE H308 0.75 to 50 A 0.75 A or less Split-Core · · 2 · H608 0.5 to 175 A 0.5 A or less Split-Core · · 1 · H701 H708 1 to 135 A 1 to 135 A 1.0 A or less N.O. 1.0 A @ 30 Vac/dc 1.0 A or less Solid-Core Solid-Core · · · H808 0.75 to 50 A 0.75 A or less Solid-Core · · · H908 2.5 to 135 A 2.5 A or less Split-Core · · · 1. Listed for use on 75 °C insulated conductors. 2. Product provides functional insulation only. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 242 Current Monitoring | Adjustable Trip Point, High Voltage Output HX09 SERIES Detect Belt Loss, Coupling Shear, and Mechanical Failure H709 H809 Low setpoint The H809 has a low (0.75 A) minimum setpoint...no need for multiple wraps of the conductor through the sensor, even on loads as small as 1/5 HP Adjustable trip point Precise current trip point setting Small in size H609 and H809 are small in size to fit easily inside small starter enclosures Status LEDs For easy setup and local indication H909 Versatility Flexibility Removable mounting bracket optimizes field versatility Bracket on H909 can be installed in three different configurations APPLICATIONS Maximize Reliability Minimize Installed Cost · Detecting belt loss, coupling shear, mechanical failure, and interlocking loads H609 · Verifying lighting circuit and other electrical service run times Hawkeye x09 Series are high performance current switches, ideal for line voltage loads. The devices are powered by the current being monitored. They are ideal for monitoring performance on unit vents, exhaust fans, recirculation pumps, and other fixed loads. · Monitoring status of industrial process equipment · Monitoring status of critical motors (compressor, fuel, etc.) · VFD output On/Off status · Fan/pump status monitoring SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Hysteresis Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Induced from monitored conductor 600 Vac RMS (UL), 300 Vac RMS (CE1) 50/60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing 10% (typical) 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation E150462 Note: Do not use the LED status indicators as evidence of applied voltage. If using this switch in an application that includes an electronically commutated motor (ECM), see Veris Application Note VN61, at veris.com. DETECTS BELT LOSS/COUPLING SHEAR! Calibrated Trip Point Fan/pump On Electrical Failure O Loss of Belt/Coupling Shear O Now you can easily detect when drive belts slip, break, or pump couplings shear. In fact, a typical HVAC motor that loses its load has a reduction of current draw of up to 50%. That's why our sensors are the industry standard for status. 243 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | Hx09 Series H609 Dimensional Drawing 2.1" (54 mm) Removable Mounting Bracket 0.6" (16 mm) 1.2" 0.7" (31 mm) (18 mm) 0.5" (13 mm) 2.5" * (64 mm) 0.4" x 0.2" (10 mm x 5 mm) Slot (2x) 2.1" (54 mm) 2.9" (74 mm) 3.5" (89 mm) Self-gripping Iris 1.0" (26 mm) H709/H709HV Dimensional Drawing H809 Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (18 mm) 0.9" (23 mm) MONITORING FAN /PUMP MOTORS FOR POSITIVE PROOF OF FLOW Wiring Diagram CONTACTOR CONTROLLER 2.8" * (71 mm) Digital Input 9 0.4" x 0.2" Slot (x2) 1.7 (43 mm) 2.3" (58 mm) H909/H909HV Dimensional Drawing 1.1" * (27 mm) Motor Fan or Pump Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) 1.1" * (27 mm) Removable Mounting Bracket 1.1" (26 mm) 3.1"** (79 mm) 1.0" (25 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" (64 mm) 3.0" (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. ORDERING INFORMATION MODEL AMPERAGE RANGE @ 50/60 HZ ONLY STATUS OUTPUT (MAX.) MIN. TRIP POINT STATUS LED HOUSING UL CE LEAD FREE H609 1.25 to 50 A N.O. 0.2 A @ 120 Vac/dc 1.25 A or less · Split-core · 1 · H709 1 to 135 A N.O. 0.2 A @ 120 Vac/dc 1.0 A or less · Solid-core · H709HV 1 to 135 A N.O. 1.0 A @ 250 Vac 1.0 A or less Solid-core · H809 0.75 to 50 A N.O. 0.2A @ 120 Vac/dc 0.75 A or less · Solid-core · 1 · H909 2.5 to 135 A N.O. 0.2 A @ 120 Vac/dc 2.5 A or less · Split-core · H909HV 2.5 to 135 A N.O. 1.0A @ 250 Vac 2.5 A or less Split-core · 1. Listed for use on 75°C insulated conductors. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 244 Current Monitoring | Current Switches: Adjustable Trip Point, N.C. Output HX06 SERIES Detect Belt Loss, Coupling Shear, and Mechanical Failure H706 H906 Adjustable trip point Versatility with four available amperage ranges Status LEDs Output status LEDs for fast set up No tubing needed Easier to install than differential pressure switches Easy placement Adjustable mounting bracket on the solid-core housing 100% solid-state No moving parts to fail Self-gripping iris Self-gripping iris on split-core housings for easy installation APPLICATIONS Maximize Reliability Minimize Installed Cost H606 H806 Hawkeye x06 Series solid- and split-core current switches provide accurate, reliable, and maintenance-free fan and pump status indication where an NC output is needed. · Monitoring fans, pumps, motors, and other electrical loads for proper operation · Detecting belt loss and motor failure...ideal for fan and pump status · Verifying lighting circuit loads · Monitoring critical motors (compressor, fuel, etc.) · Monitoring industrial process equipment status (OEM) SPECIFICATIONS Sensor Power Insulation Class Temperature Range Humidity Range Hysteresis Off State Leakage On State Voltage Drop Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 5 to 30 Vdc 600 Vac RMS (UL), 300 Vac RMS (CE) -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing 10% Typical 34 A @ 5 Vdc, 200 µA @ 30 Vdc 1.9 Vdc max@ 0.1 A H300: 22 to 16 AWG (0.3 to 1.3 mm2) Others: 24 to 14 AWG (0.2 to 2.1 mm2) H300: 7 in-lbs (0.8 N-m) Others: 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation DETECTS BELT LOSS/COUPLING SHEAR! Calibrated Trip Point Fan/pump On Electrical Failure O Loss of Belt/Coupling Shear O Now you can easily detect when drive belts slip, break, or pump couplings shear. In fact, a typical HVAC motor that loses its load has a reduction of current draw of up to 50%. That's why our sensors are the industry standard for status. E150462 Note: Do not use the LED status indicators as evidence of applied voltage. (a) VFD systems generate fields that can disrupt electrical devices. Ensure that these fields are minimized and are not affecting the sensor. 245 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | Hx06 Series H606 Dimensional Drawing H806 Dimensional Drawing MONITORING FAN/PUMP MOTORS FOR POSITIVE PROOF OF FLOW (H606 & H806) Wiring Diagram Removable Mounting Bracket Removable/Adjustable Mounting Bracket 2.1" (54 mm) 0.6" (16 mm) 1.2" 0.7" (31 mm) (18 mm) 0.5" (13 mm) 2.5" * (64 mm) 0.7" (18 mm) 0.4" x 0.2" (10 mm x 5 mm) Slot (2x) 2.1" (54 mm) 2.9" (74 mm) 3.5" (89 mm) Self-gripping Iris 1.0" (26 mm) 0.4" x 0.2" Slot (x2) 1.7 (43 mm) 2.3" (58 mm) 0.9" (23 mm) 2.8" * (71 mm) 1.1" * (27 mm) CONTACTOR Motor DDC CONTROLLER -+ -+ - Digital + Input 5 to 30 Vdc POWER SOURCE Fan or Pump H706 Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) 1.1" * (27 mm) H906 Dimensional Drawing Removable Mounting Bracket 1.1" (26 mm) 3.1"** (79 mm) 1.0" (25 mm) 0.8" (21 mm) MONITORING FAN/PUMP MOTORS FOR POSITIVE PROOF OF FLOW (H706 & H906) Wiring Diagram Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris CONTACTOR DDC CONTROLLER + Digital + + - Input Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" 3.0" (64 mm) (76 mm) 1.4"* (36 mm) Motor -+ 5 to 30 Vdc POWER SOURCE Fan or Pump * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. ORDERING INFORMATION MODEL AMPERAGE RANGE STATUS OUTPUT (MAX.) MIN. TRIP POINT HOUSING STATUS LED UL CE H606 1.25 to 50 A 1.25 A or less Split-Core · · 1 · H706 H806 1 to 135 A 0.75 to 50 A 1.0 A or less N.C. 0.1 A @ 30 Vdc 0.75 A or less Solid-Core Solid-Core · · · · · · H906 2.5 to 135 A 1. Listed for use on 75°C insulated conductors. 2.5 A or less Split-Core · · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 246 Current Monitoring | Current Switches: Auto Calibration with LCD Display H11D LCD Display Backlit LCD View the monitored current (up to 200 A)...no need for expensive handheld meters and offers easy visibility in dark enclosures Versatility Slide-switch selectable trip point limits Maximize Reliability Minimize Installed Cost H11D TM The Hawkeye TruStat H11D is a microprocessor based, self-learning, self-calibrating current switch. It is designed for user ease, providing calibration-free status for both under and overcurrent, an LCD display, and slide-switch selectable trip point limits. At initial power-up, the H11D automatically learns the average current on the line with no action required by the installer. Once a current is learned, the switch monitors for changes in current greater than the selected range. Simplified Automatic troubleshooting calibration Records and displays the Reduced errors and installation amperage level that trips the alarm costs Microcontrollerbased learning technology Automatically learns load upon initial power-up...minimizes calibration labor Reset function Reset function can be used when unpowered...reduces the possibility of an arc flash incident APPLICATIONS · HVAC fans, pumps, and blowers · Monitoring status of industrial process equipment SPECIFICATIONS Sensor Power Response Time Accuracy Frequency Range Temperature Range Humidity Range LCD Backlight On-State Resistance Off-State Resistance Setpoint Target Range, Switch Setting A1 Setpoint Target Range, Switch Setting B1 Switch Setting C1 Alarm Reset Range2 Setpoint Calibration Learn Period Normal-to-Alarm Output Delay Alarm-to-Normal Output Delay Induced from monitored conductor 1 sec. ±2% of full scale 50/60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing Off at low currents; illuminates when monitored current exceeds 4.5 A; flashes during an alarm state while current remains above 4.5 A 1.0 1.0 M ±40% of learned nominal current; max. learned current of 142 A to enable an upper trip limit at or below 200 A ±60% of learned nominal current;max. learned current of 125 A to enable an upper trip limit at or below 200 A On/Off Status; contacts are closed while amperage is above 2.5 A ±5% of learned nominal current 30 sec.; self-learning, pushbutton reset 1 sec. maximum 30 sec. nominal Insulation Class Hysteresis Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 600 Vac RMS (UL); 300 Vac RMS (CE) 10% (typical) 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation E212445 1. Trip point switch positions A and B are not for use in applications where the current will fluctuate by more than 40% (A) or 60% (B) of the nominal current. If the current will fluctuate by more than 60%, use the H11D for on/off status (position C) only. 2. The upper trip limit alarm resets when the current drops by 5% of the learned nominal current limit. The lower trip limit alarm resets when the current rises by 5% of learned nominal current limit. Specification Note: For CE compliance, conductor shall be insulated according to IEC610101 Do not use the LCD as evidence of applied voltage. 247 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | H11D DIMENSIONAL DRAWING Removable Mounting Bracket 1.1" (26 mm) 3.1"** (79 mm) 1.0" (25 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris 2.8" (70 mm) Ø 0.3" (8 mm) 2.5" (64 mm) 3.0" (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. WIRING DIAGRAM CONTACTOR Insulated Conductor CONTROLLER Digital Input MOTOR Fan or Pump FUNCTIONAL DRAWING ALARM RESET 5% Typical NOMINAL LEARNED CURRENT ØAAC POWER ON LEARN (MODE) 30 SEC NORMAL (CURRENT MONITOR MODE) ALARM (MODE) NORMAL (CURRENT MONITOR MODE) 1 SEC. DELAY 30 SEC. DELAY POWER LOSS ØAAC ALARM (MODE) Upper Alarm Trip Limit Normal Current Lower Alarm Trip Limit ORDERING INFORMATION MODEL AMPERAGE RANGE1 STATUS OUTPUT NOMINAL TRIP POINT TARGET RANGE HOUSING STATUS LED UL CE H11D 2.5 to 200 A @ 60 Hz 3.0 to 200 A @ 50 Hz N.O. 1.0 A @ 30 Vac/dc ±40%, ±60%, or on/off (user selectable) Split-core · · 2 · 1. To enable the upper trip limit alarm, the max. learned current for switch setting "A" is 142 A, and the max. learned current for switch setting "B" is 125 A. Switch setting "C" is for on/off status only, so the upper trip limit alarm does not apply. 2. Listed for use on 75 °C insulated conductors. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 248 Current Monitoring | VFD Current Switch: Auto Calibration H614 Automatically Learns At Initial Power-Up Microcontroller based learning technology Automatically learns load upon initial power-up...minimizes calibration labor Saves space Small size fits easily inside small starter enclosures Automatic trip 100% solid state point 100% solid state...no moving Automatic trip point (1.5 to 150 parts to fail H614 Amps, 12 to 115 Hz)...detect abnormal events Maximize Reliability TM Minimize Installed Cost The Hawkeye H614 is a microprocessor based, self-learning, selfcalibrating current-sensitive switching device designed for use with VFD systems. At initial power-up, the H614 automatically learns the average current on the line with no action required by the installer. Once a current is learned, the switch monitors for changes in current greater than ±20% of the learned load. When calibrated for a given VFD system, the H614 is tolerant of gradual drifts in frequency due to expected conditions, such as an accumulation of debris in a filter, while still detecting a sudden drop due to a potential abnormal system condition (e.g., belt loss or other mechanical failure). Under- and over-load Microcontroller based learning technology...automatically learns load APPLICATIONS · Monitoring fans, pumps, motors, and other electrical loads for proper operation · Detecting belt loss and motor failure...ideal for fan and pump status Flexibility Removable mounting bracket for installation flexibility · Verifying lighting circuit loads · Monitoring critical motors (compressor, fuel, etc.) · Monitoring industrial process equipment status (OEM) SPECIFICATIONS Sensor Power Response Time Learn Time Frequency Range in Conductor Temperature Range Humidity Range Alarm Limits Normal-to-Alarm Status Output Delay Alarm-to-Normal Status Output Delay Off Delay Contact Ratings Insulation Class Terminal Block Wire Size Terminal Block Torque Induced from monitored conductor 1 sec. 15 sec. learn period after frequency stabilizes 12 to 115 Hz1 -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing ±20% of learned current in every 5 Hz freq. band2 Approx. 7 sec. 1 sec. nominal3 <30 sec. nominal 30 Vac/dc, 1 A 600 Vac (UL); 300 Vac RMS (CE) 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 5 years UL508 open device, CE: EN61010-1, CAT III, Pollution Degree 2 E150462 1. VFD systems generate fields that can disrupt electrical devices. Ensure that these fields are minimized and are not affecting the sensor. 2. The H614 is not intended for use in applications where the current is expected to fluctuate by more than 20% due to acceptable causes other than VFD driven changes. 3. If the H614 experiences a momentary loss of power, the Alarm-to-Normal output delay may exceed 1 sec. Specification Note: For CE compliance, conductor shall be insulated according to IEC610101 The product design provides for basic insulation only. Use wire with minimum 75°C rated insulation. Do not use the LED status indicators as evidence of applied voltage. This sensor detects abnormal operation by looking for sudden changes in current across the entire frequency range. In Learn mode, the sensor calculates a margin 20% above and 20% below the learned frequency curve. An abnormal condition in the circuit is one that falls outside this margin. 249 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING Removable Mounting Bracket 2.1" (54 mm) 0.6" (16 mm) 1.2" 0.7" (31 mm) (18 mm) 0.5" (13 mm) 2.5" * (64 mm) 0.4" x 0.2" (10 mm x 5 mm) Slot (2x) 2.1" (54 mm) Self-gripping Iris 1.0" (26 mm) 2.9" (74 mm) 3.5" (89 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. Current Monitoring | H614 WIRING DIAGRAM VFD Hawkeye 614 VEPRoIrStlaINndD, OU1rS-e8gT0oR0nI-E395S742-28®3556 BYPASS DEVICE (if used) CONTROL Digital Input Fan or Pump NOTE: The H614 is not intended for use in staged pump, variable inlet vane, and other applications in which the amperage changes under normal operation, independent of frequency. NOTE: (Optional) For added sensitivity in detecting amperage changes, use H614 devices on all three phases of the VFD Motor Learned Current Band 1 Band 2 Band 3 Band 4 Band 5 Band 6 Band 7 Band 8 Band 9 Band 10 Band 11 Band 12 Band 13 Band 14 Band 15 Band 16 Band 17 Band 18 Band 19 Band 20 PRODUCT FUNCTIONS Constant Torque Constant Power Elbow Current Elbow Band Frequency +20% (upper trip limit) Normal Operation -20% (lower trip limit) SENSOR MODE Learning Mode (first 15 sec of operation after frequency stabilizes) On/ Off Status only Learn mode incomplete. VFD system does not meet abnormal condition detection criteria Current is not adequate for the device to detect abnormal conditions Status OK Alarm STATUS LED BLINK PATTERN Alternating Red/Green (1 per sec.) Green blink (5 times per sec. after 15 sec of stable frequency) No LED Green blink (1 per sec.) Red blink (1 per sec.) CONTACTS Closed Closed Closed Closed Open HOW IT WORKS During setup, the H614 automatically determines the normal amperage and frequency profile and stores it in memory. Then the microprocessor monitors for amperage changes greater than ±20% of this learned curve, indicating a potential system failure. ORDERING INFORMATION USAGE EXAMPLE The H614 is designed for HVAC fan and blower systems, as well as some single stage pumping systems involving consistent viscosity liquids. If an H614 is installed on one phase of the VFD, it detects changes in that phase that result from the VFD compensating for changes elsewhere in the system. Alternatively, for increased sensitivity, H614s can be used on all three phases for immediate detection of phase balance changes anywhere in the system. MODEL H614 AMPERAGE RANGE 1.5 to 150 A1 FREQUENCY RANGE 12 to 115 Hz STATUS OUTPUT NOMINAL TRIP POINT TARGET RANGE N.O. 1.0 A @ 30 Vac/dc ±20% in each of 20 bands HOUSING Split-core STATUS LED · UL CE · 2 · 1. If the current is above 1.5 A, but neither LED is illuminated, the H614 is considered to be in on/off status mode. 2. Listed for use on 75°C insulated conductors. ACCESSORIES P. 279 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 250 Current Monitoring | VFD Switches and Current Sensors H720, H904 & H934 Variable Frequency Drive Monitoring and Control Also see H614. Load side monitoring Automatically compensates Suitable for llad side monitoring of VFDs (H720) Automatically compensates for the effects of frequency and amperage changes in monitored conductor associated with VFDs (H901/934) Precise scaling Nuisance H934 Adjustable zero and span for reduction H904 H720 precise scaling (H720) Provides a secondary setpoint option of 50% of the originally measured current (H901/934) TM U.S. Patent No. 5,705,989 Maximize Reliability Minimize Installed Cost Hawkeye 720, 904 and 934 current monitoring devices provide unique solutions for accurately monitoring status of motors controlled by variable frequency drives. The microprocessor-based H904 and H934 store the sensed amperage values for normal operation at various frequency ranges in non-volatile memory. This information allows the device to distinguish between a reduced amp draw due to normal changes in the frequency and an abnormal amp drop due to belt loss or other mechanical failures. The relay on the H934 is isolated from the current switch, and all relay connections are externally accessible on the device. The H720 analog output corresponds to current in the monitored conductor from 10 to 80 Hz. 0.5% accuracy Accurate to 0.5% of full scale (H720) Rapid troubleshooting LED indicates normal and alarm conditions (H901/934) APPLICATIONS · Monitoring positive status on motors controlled by variable frequency drives · Replacing pressure switches · Measuring current and load trending DETECTS BELT LOSS/COUPLING SHEAR! Calibrated Trip Point Fan/pump On Electrical Failure SPECIFICATIONS Sensor Power Insulation Class Frequency Range: H720 H904/H934 Temperature Range Humidity Range Off Delay (H904/H934) Accuracy (H720) O Loss of Belt/Coupling Shear O Now you can easily detect when drive belts slip, break, or pump couplings shear. In fact, a typical HVAC motor that loses its load has a reduction of current draw of up to 50%. That's why our sensors are the industry standard for status. H904/H934: Induced from monitored conductor; H720: 12 to 30 Vdc 600 Vac RMS 10 to 80 Hz; 20 to 34 Hz for on/off status, 34 to 75 Hz for belt loss indication On/Off status for Variable Frequency Drive (VFD) outputs1 -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing 0 sec to 2 min. 0.5% of 200 A (combined linearity, hysteresis, and repeatability) Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing CAT III, Pollution Degree 2, basic insulation E150462 Note: Do not use the LED status indicators as evidence of applied voltage. 1. VFD systems generate fields that can disrupt electrical devices. Ensure that these fields are minimized and are not affecting the sensor. 251 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | H720, H904 & H934 H720 Dimensional Drawing H904/934 Dimensional Drawing Removable/Adjustable Mounting Bracket 0.33" (9 mm) 0.7" (19 mm) 3.13" (80 mm) 2.15" (55 mm) 3.0" (76 mm) 1.00" (26 mm) Removable Mounting Bracket 1.0" (25 mm) 1.1" (26 mm) 3.1"** (79 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris 2.8" (70 mm) Ø 0.3" (8 mm) 2.5" 3.0" (64 mm) (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. EXAMPLE LINEAR OUTPUT (H720) Scale software as shown Requires 12 to 30 Vdc for sensor power 20 mA H934 Relay Contact Ratings Resistive - 5A @ 250 Vac, 30 Vdc Typical Coil Performance Voltage AC DC 24V 10 mA 10 mA MONITORING FAN /PUMP MOTORS FOR POSITIVE PROOF OF FLOW Wiring Diagram CONTACTOR VFD CONTROL Digital Input Fan or Pump Motor Note: The H904 is not intended for use in staged pump or variable inlet vane applications. Voltage Output + CONTROLLER Voltage input 250 = 1 to 5 Vdc 500 = 2 to 10 Vdc SENSOR OUTPUT 4 mA 0 A 200 A SENSED AMPS ORDERING INFORMATION MODEL H720 H904 H934 AMPERAGE RANGE Lower limit: 0 A Upper limit: 20 to 200 A 3.5 to 135 A, 20 to 75 Hz STATUS OUTPUT 4 to 20mA Max. N.O. 0.1 A @ 30 Vac/dc MIN. TRIP POINT n/a 3.5 A or less Note: For auto-calibrating model see H614. RELAY TYPE HOUSING STATUS LED none Solid-core · none · SPST, N.O. Split-core · RELAY POWER LED UL · · · · · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 252 Current Monitoring | ECM-Optimized Current Switch H6ECM Split-core Current Switch, Proof of Rotation (Flow) for ECM Systems Maximize Reliability Minimize Installed Cost H6ECM05 TM High performance High performance device, split-core housing Self-gripping iris Self-gripping iris for easy installation Precise Precise current trip point setting Status LEDs Status LEDs for easy setup and local indication Small size Fits easily inside small enclosures Up to 1 Amp status output Increased application flexibility The H6ECM is a current-sensitive switching device that monitors current (amperage) in the conductor passing through it. A change in amperage in the monitored conductor that crosses the switch (setpoint) causes the resistance of the FET status output to change state, similar to the action of a mechanical switch. The status output is suitable for connection to building controllers or other appropriate data acquisition equipment operating at up to 30 V. The product requires no external power supply to generate its output. Electrically Commutated Motors (ECMs) are increasingly common as more energy conservation measures are implemented. The ECM is a brushless DC motor that is supplied AC power, converts that power to DC current and uses electronic switching to control the motor rotation. The ECM motor shaft speed can be reduced to save energy, resulting in lower cost and less component wear. The H6ECM is optimized to provide meaningful proof of rotation which verifies that the ECM motor is operating as expected. APPLICATIONS · Systems with Electrically Commutated Motors such as cooling fans or compressor motors with off-state (keep alive) current less than 0.5 A SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Hysteresis Accuracy Amperage Range Status Output Ratings Setpoint Off State Resistance On State Resistance Induced from the monitored conductor 600 Vac RMS 60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing 10% typical ±10% 0.5 to 175 A continuous N.O. 1.0A @ 30 Vac/dc, not polarity sensitive 0.5 A (keep alive current < 0.5 A) Open switch represents > 1 M Closed switch represents < 200 m Terminal Block Max. Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Installation Category 24 to 14 AWG (0.2 to 2.1mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL508 open device listing CAT III, Pollution Degree 2 NoE1t5e0s4:6F2or applications requiring double or reinforced insulation, please contact the factory. The product design provides basic insulation only. Do not use the LED indicators as evidence of applied voltage. 253 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | H6ECM DIMENSIONAL DRAWING 2.1" (54 mm) Removable Mounting Bracket 0.6" (16 mm) 1.2" 0.7" (31 mm) (18 mm) 0.5" (13 mm) 2.5" * (64 mm) 0.4" x 0.2" (10 mm x 5 mm) Slot (2x) 2.1" (54 mm) Self-gripping Iris 1.0" (26 mm) 2.9" (74 mm) 3.5" (89 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. WIRING DIAGRAM AC Power Insulated Conductor (line or load) ONLY Digital Input ORDERING INFORMATION MODEL AMPERAGE RANGE STATUS OUTPUT TRIP POINT STATUS LED UL H6ECM05 0.5 to 175 A N.O. 1.0 A @ 30 Vac/dc 0.5 A · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 254 Current Monitoring | Current Switches with Relay: Fixed Trip Point HX30/40/50 SERIES On/Off Status and Control in One Package TM H730 H930 On/off status On/off status and command relay in a single labor and space saving device SPDT command relay H740 and H940 feature a SPDT command relay Detect belt loss Cost-effectively monitor start/stop, unit vents, fan coils, exhaust fans, and other loads where belt loss is not a concern No tubing necessary Easier to install than differential pressure switches Easy setup No calibration required...easy setup and operation Maximize Reliability Minimize Installed Cost The Hawkeye Relay Combination Series combines an on/off status sensor and command relay in one package, saving the labor, wire runs, and space required to mount a separate relay. The switch and relay (not electrically connected) are in the same housing, saving space and cost. It is ideal for monitoring and controlling motors where belt loss is not a concern. SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Induced from monitored conductor 600 Vac RMS 50/60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation APPLICATIONS · Monitoring direct drive units, exhaust fans, and other fixed loads · Monitoring on/off status of electrical loads · Starting/stopping motors RELAY CONTACT RATINGS Hx30, Hx50 (SPST, N.O.) Resistive 10 A @ 250 Vac, 30 Vdc Inductive 5 A @ 250 Vac, 30 Vdc Hx40 (SPDT) Resistive 8 A @ 250 Vac, 30 Vdc Inductive 3.5 A @ 250 Vac, 30 Vdc TYPICAL COIL PERFORMANCE Voltage AC DC 24V 10 mA 10 mA Pull In Voltage Hx30 20.1 Vdc Hx40 20.1 Vdc Hx50 8.4 Vdc Drop Out Voltage Hx30 5.2 Vdc Hx40 5.2 Vdc Hx50 3.0 Vdc E150462 Note: Do not use the LED status indicators as evidence of applied voltage. 255 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com H730/740/750 Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) 1.1" * (27 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. Current Monitoring | Hx30/40/50 Series START/STOP MONITORING OF FAN/PUMP MOTORS Wiring Diagram CONTACTOR CONTROLLER Digital Output (Relay Coil) Digital Input (Status) CONTROL POWER Fan or Pump Motor H930/940/950 Dimensional Drawing Removable Mounting Bracket 1.1" (26 mm) 3.1"** (79 mm) 1.0" (25 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" (64 mm) 3.0" (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. RELAY CONTROLLED DIRECTLY BY STATUS CONTACTS Wiring Diagram Relay Coil Power Source RELAY LOAD ORDERING INFORMATION MODEL H730 H740 H750 H930 H940 H950 AMPERAGE RANGE 0.5 to 200 A 0.5 to 200 A 0.5 to 200 A 1.5 to 200 A 1.5 to 200 A 1.5 to 200 A STATUS OUTPUT (MAX.) N.O. 1.0 A @ 30 Vac/dc TRIP POINT RELAY 0.5 A or less SPST, N.O. 0.5 A or less SPDT 0.5 A or less SPST, N.O. 1.5 A or less SPST, N.O. 1.5 A or less SPDT 1.5 A or less SPST, N.O. RELAY COIL HOUSING RELAY POWER LED UL 24 Vac/dc Solid-core · · 24 Vac/dc Solid-core · · 12 Vdc nom. Solid-core · · 24 Vac/dc Split-core · · 24 Vac/dc Split-core · · 12 Vdc nom. Split-core · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 256 Current Monitoring | Current Switches with Relay: Adjustable Trip Point H735, HX38,HX48, HX58 SERIES Status and Control in One Package TM H938 H738 Maximize Reliability Minimize Installed Cost The Hawkeye Relay Combination Series is the ideal solution for the automation installer. These units combine a current switch and relay into a single package, reducing the space required for total control of fans and pumps. The current switch and relay operate independently of one another. These devices allow start/stop control and status monitoring with one device instead of two. Combined relay & status Combines command relay and fan/ pump status sensor in a single, easy-to-install unit Two outputs H748 and H948 feature a SPDT command relay...control two outputs with a single relay Fan & pump status Detect belt loss and motor failure...ideal for fan and pump status Added flexibility Bracket on H938, H948, and H958 can be installed in three different configurations Polarity insensitive Easy setup Relay and status LEDs Polarity insensitive status outputs...fast and easy installation APPLICATIONS · Starting/stopping and monitoring positive status of motors · Detecting belt loss and coupling shear DETECTS BELT LOSS/COUPLING SHEAR! Calibrated Trip Point Fan/pump On Electrical Failure O Loss of Belt/Coupling Shear O Now you can easily detect when drive belts slip, break, or pump couplings shear. In fact, a typical HVAC motor that loses its load has a reduction of current draw of up to 50%. That's why our sensors are the industry standard for status. SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Hysteresis Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Induced from monitored conductor 600 Vac RMS 50/60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing 10% Typical 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation E150462 Note: Do not use the LED status indicators as evidence of applied voltage. RELAY CONTACT RATINGS H735 (SPST, N.O.) Resistive 5 A @ 250 Vac, 30 Vdc Inductive 3 A @ 250 Vac, 30 Vdc Hx38, Hx58 (SPDT N.O.) Resistive 10 A @ 250 Vac, 30 Vdc Inductive 5 A @ 250 Vac, 30 Vdc Hx48 (SPDT) Resistive 8 A @ 250 Vac, 30 Vdc Inductive 3.5 A @ 250 Vac, 30 Vdc TYPICAL COIL PERFORMANCE Voltage AC DC 24V 10 mA 10 mA 12V (Hx58) 20 mA Pull-in Voltage Hx3x 20.1 Vdc Hx48 20.1 Vdc Hx58 8.4 Vdc Drop-out Voltage Hx3x 5.2 Vdc Hx48 5.2 Vdc Hx58 3.0 Vdc 257 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com H735/738/748/758 Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) 1.1" * (27 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. H938/948/958 Dimensional Drawing Removable Mounting Bracket 1.1" (26 mm) 3.1"** (79 mm) 1.0" (25 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" 3.0" (64 mm) (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. Current Monitoring | H735, Hx38, Hx48, Hx58 Series START/STOP MONITORING OF FAN /PUMP MOTORS Wiring Diagram CONTROLLER Digital Input (Status) Digital Output (Relay Coil) CONTACTOR CONTROL POWER Motor Fan or Pump RELAY CONTROLLED DIRECTLY BY STATUS CONTACTS Wiring Diagram Relay Coil Power Source RELAY LOAD ORDERING INFORMATION MODEL AMPERAGE RANGE H735 1 to 135 A H738 1 to 135 A H748 1 to 135 A H758 1 to 135 A H938 2.5 to 135 A H948 2.5 to 135 A H958 2.5 to 135 A STATUS MIN. TRIP OUTPUT (MAX.) POINT 0.1 A @ 30 Vac/dc 1 A or less 1 A or less 1 A or less 1 A or less 1.0 A @ 30 Vac/dc 2.5 A or less 2.5 A or less 2.5 A or less RELAY COIL VOLTAGE SPST, N.O. 24 Vac/dc SPST, N.O. 24 Vac/dc SPDT 24 Vac/dc SPST, N.O. 12 Vdc nom. SPST, N.O. 24 Vac/dc SPDT 24 Vac/dc SPST, N.O. 12 Vdc nom. HOUSING Solid-core Solid-core Solid-core Solid-core Split-core Split-core Split-core STATUS LED · · · · · · · RELAY POWER LED UL · · · · · · · · · · · · · · ACCESSORIES P. 279 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 258 Current Monitoring | C urrent Switches with Relay: Adjustable Trip Point, High Voltage Output HX39, HX49 & HX59 SERIES Status and Control in One Package TM H939 H739 Maximize Reliability Minimize Installed Cost Hawkeye Relay Combination Series high voltage output current switches are the ideal solution for the automation installer. These units combine a current switch and relay into a single package, reducing the space required for total control of fans and pumps. The integrated current switch and relay operate independently of one another. All relay connections are externally available for maximum flexibility. These products perform the functions of start/stop and status monitoring with one device instead of two. SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Hysteresis Terminal Block Wire Size Terminal Block Torque WARRANTY Agency Approvals AGENCY APPROVALS Limited Warranty Induced from monitored conductor 600 Vac RMS 50/60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing 10% Typical 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation 5 years E150462 Do not use the LED status indicators as evidence of applied voltage. Combined relay & status Combines command relay and fan/ pump status sensor in a single, easy-to-install unit No tubing Easier to install than differential pressure switches...no tubing needed Polarity insensitive Polarity insensitive status outputs...fast and easy installation Detect belt loss Detect belt loss & motor failure... ideal for fan and pump status Easy setup Relay and status LEDs APPLICATIONS · Starting/stopping and monitoring positive status of motors Added flexibility Bracket on H939, H949, and H959 can be installed in three different configurations · Detecting belt loss and coupling shear DETECTS BELT LOSS/COUPLING SHEAR! Calibrated Trip Point Fan/pump On Electrical Failure O Loss of Belt/Coupling Shear O Now you can easily detect when drive belts slip, break, or pump couplings shear. In fact, a typical HVAC motor that loses its load has a reduction of current draw of up to 50%. That's why our sensors are the industry standard for status. Relay Contact Ratings Hx39, Hx59 (SPST, N.O.) Resistive 10 A @ 250 Vac, 30 Vdc Inductive 5 A @ 250 Vac, 30 Vdc Hx38, Hx58 (SPDT) Resistive 8 A @ 250 Vac, 30 Vdc Inductive 3.5 A @ 250 Vac, 30 Vdc Typical Coil Performance Voltage AC DC 24V 10 mA 10 mA 12V (Hx58) 20 mA Pull-in Voltage Hx39 20.1 Vdc Hx49 20.1 Vdc Hx59 8.4 Vdc Drop-out Voltage Hx39 5.2 Vdc Hx49 5.2 Vdc Hx59 3.0 Vdc 259 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | Hx39, Hx49 & Hx59 Series H739/H749 Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) 1.1" * (27 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. START/STOP MONITORING OF FAN /PUMP MOTORS Wiring Diagram CONTACTOR CONTROLLER Digital Output (Relay Coil) Digital Input (Status) CONTROL POWER Fan or Pump Motor H939/H949/H959 Dimensional Drawing Removable Mounting Bracket 1.0" (25 mm) 1.1" (26 mm) 3.1"** (79 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris 2.8" (70 mm) Ø 0.3" (8 mm) 2.5" (64 mm) 3.0" (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. RELAY CONTROLLED DIRECTLY BY STATUS CONTACTS Wiring Diagram Relay Coil Power Source RELAY LOAD ORDERING INFORMATION MODEL H739 H749 H939 H949 AMPERAGE RANGE 1 to 135 A 1 to 135 A 2.5 to 135 A 2.5 to 135 A STATUS OUTPUT (MAX.) N.O. 0.2 A @ 120 Vac/dc MIN. TRIP POINT 1 A or less 1 A or less 2.5 A or less 2.5 A or less RELAY TYPE SPST, N.O. SPDT SPST, N.O. SPDT H959 2.5 to 135 A 2.5 A or less SPST, N.O. RELAY COIL 24 Vac/dc 24 Vac/dc 24 Vac/dc 24 Vac/dc 12 Vdc nom. HOUSING Solid-core Solid-core Split-core Split-core Split-core STATUS LED · · · · RELAY POWER LED UL · · · · · · · · · · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 260 Current Monitoring | Current Transducers: 4 to 20 mA Analog Output H721XC SERIES & H921 Load Trending with 4 to 20 mA Output H721HC H921 TM Maximize Reliability Minimize Installed Cost Hawkeye Relay Combination Series high voltage output current switches are the ideal solution for the automation installer. These units combine a current switch and relay into a single package, reducing the space required for total control of fans and pumps. The integrated current switch and relay operate independently of one another. All relay connections are externally available for maximum flexibility. These products perform the functions of start/stop and status monitoring with one device instead of two. SPECIFICATIONS Sensor Power 30 mA (max) @ 12 to 30 Vdc Insulation Class 600 Vac RMS (UL), 300 Vac RMS (CE) Frequency Range 50/60 Hz Temperature Range -15 to 60 °C (5 to 140 °F) Humidity Range 10 to 90% RH non-condensing Accuracy ±2% F.S. from 10% to 100% of selected range, but not less than ±0.4 A Response Time 2 sec. Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm2) Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) WARRANTY Limited Warranty 5 years AGENCY APPROVALS Agency Approvals UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation Lower costs Factory calibrated Power the sensor, and receive the signal with only two wires...lower Factory calibrated switch- cabling and commissioning costs than with traditional 3-wire sensors selectable ranges for high resolution and installation ease Retrofit Self-gripping, split-core design for fast retrofit installation...no need to remove conductor (H921) 3 field-selectable Three field-selectable ranges per unit...fewer versions to choose from, stock, and install New construction Economical solid-core features adjustable bracket for easy alignment (H721 Series) Installation flexibility Removable mounting bracket for installation flexibility APPLICATIONS · Load trending · Motor control · Fan/pump status EXAMPLE LINEAR OUTPUT Scale software as shown 20mA SENSOR OUTPUT 4mA 0A Selected Range* SENSED AMPS *Factory calibrated ranges selected with the amperage range switch E150462 261 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | H721xC Series & H921 H721LC/H721HC Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) 1.1" * (27 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. H921 Dimensional Drawing Removable Mounting Bracket 1.0" (25 mm) 1.1" (26 mm) 3.1"** (79 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" 3.0" (64 mm) (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. MONITORING FAN /PUMP MOTORS FOR POSITIVE PROOF OF FLOW Wiring Diagram DDC CONTROLLER Analog Input + CONTACTOR +- 12 to 30Vdc Power Source Voltage Output Motor Fan or Pump + CONTROLLER Voltage input 250 = 1 to 5 Vdc 500 = 2 to 10 Vdc ORDERING INFORMATION MODEL AMPERAGE RANGE SENSOR OUTPUT HOUSING UL CE H721LC 0 to 10/20/40 A Solid-Core · · H721HC 0 to 50/100/200 A 4 to 20 mA DC Solid-Core · · H921 0 to 30/60/120 A Split-Core · 1 · 1. Listed for use on 75 °C insulated conductors. Note: For 10 to 80 Hz applications, see the H720 VFD sensor. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 262 Current Monitoring | C urrent Transducers: 4 to 20 mA Analog Output, High Current Monitoring HX21 & HX21SP SERIES Large Load Trending with 4 to 20 mA Output H321 TM Maximize Reliability Minimize Installed Cost Hawkeye x21/x21SP analog current transducers provide reliable load trending information for large motor loads (up to 2400 A), with a proportional 4 to 20 mA signal. Three devices are available, each with a different amperage range. The Hx21 versions include a span potentiometer that allows each sensor to be calibrated for maximum resolution. The Hx21SP versions are factory-calibrated at a range specified by the customer. SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Accuracy Response Time Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 30 mA (max) @ 12 to 30 Vdc 600 Vac RMS (UL), 300 Vac RMS (CE) 50/60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH, non-condensing ±2% from 10 to 100% of full scale 2 sec. 12 AWG (3.3 mm2) - 22 AWG (0.33 mm2) 7 to 8 in-lbs (0.8 to 0.9 N-m) 5 years UL 508 open device listing, CE: EN61010-1, (H221, H321 only)CAT III, Pollution Degree 2, basic insulation Split-core design Split-core design for easy installation and fast retrofits Loop powered Loop powered 4 to 20 mA output No need for external CTs No need for external CTs on large conductors Two-wire design Two-wire design reduces wiring cost Large openings Large openings for heavy conductors Field flexibility Hx21 models offer zero and span adjustments for field flexibility APPLICATIONS · Load trending of large motors and other loads up to 2400 A · Monitor critical motors (compressor, fuel, etc.) EXAMPLE LINEAR OUTPUT Scale software as shown 20mA SENSOR OUTPUT 4mA 0A * SENSED AMPS *Adjusted with Span Potentiometer for Hx21 models; Factory-set per customer specification for Hx21SP models 100 to 300A (H221/H221SP) 300 to 800A (H321/H321SP) 1000 to 2400A (H421/H421SP) E150462 263 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING Current Monitoring | Hx21 & Hx21SP Series MONITORING FAN /PUMP MOTORS LOADS Wiring Diagram Voltage Output ORDERING INFORMATION MODEL H221 4 mA (Lower Limit) AMPERAGE RANGE 20 mA (Upper Limit) 100 to 300 A SENSOR OUTPUT HOUSING UL · 1 H221SP 100, 150, 200, 250, or 300 A2 · 1 H321 H321SP 300 to 800 A 0 A 300, 400, 500, 600, 700, or 800 A2 · 1 4 to 20 mA DC Split-core · 1 H421 1000 to 2400 A H421SP 1000, 1200, 1400, 1600, 1800, 2000, 2200, or 2400 A2 1. Listed for use on 75 °C insulated conductors. 2. Factory calibrated - not field adjustable. Note: When ordering HxxxSP versions, specify upper current limit for factory calibration (device is not field adjustable). CE LEAD FREE · · · · · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 264 Current Monitoring | Current Transducers: 0 to 5 Vdc Analog Output HX22 SERIES Load Trending with 0 to 5 Vdc Output H722 LC H822 Maximize Reliability Minimize Installed Cost H922 TM H622-xx Self-powered analog Self-powered analog current sensor simplifies installation New construction Economical solid-core models feature adjustable bracket for easy alignment (H722xC) No external power required No external power required for sensor Factory calibrated Factory calibrated ranges for increased flexibility and resolution Retrofit Self-gripping, split-core design for fast retrofit installation...no need to remove conductor (H622-xx, H922) No jumpers No jumpers on unit...reduces installation error The Hawkeye 622-xx, 722, 822, and 922 provide accurate load trending information with a proportional 0 to 5 Vdc output signal. Slide-switches provide easy field selection of monitored amperage range without jumpers (available on some models). SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Accuracy Response Time Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Induced from monitored conductor 600 Vac RMS (UL), 300 Vac RMS (CE) 50/60 Hz nominal -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing ±2% F.S. from 10% to 100% (range) 2 sec. 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing; CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation APPLICATIONS · Load trending · Motor control · Positive proof of flow EXAMPLE LINEAR OUTPUT Scale software as shown 5 Vdc SENSOR OUTPUT 0 Vdc 0 A Selected Range* SENSED AMPS *Factory calibrated ranges selected with the amperage range switch E150462 265 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | Hx22 Series H622-XX Dimensional Drawing Removable Mounting Bracket 2.1" (54 mm) 0.6" (16 mm) 1.2" 0.7" (31 mm) (18 mm) 0.5" (13 mm) 2.5" (64 mm) H722LC/H722HC Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) MONITORING FAN /PUMP MOTORS FOR POSITIVE PROOF OF FLOW Wiring Diagram CONTROLLER Analog Input 0 to 5 Vdc CONTACTOR 2.1" (54 mm) 0.4" x 0.2" (10 mm x 5 mm) Slot (2x) 2.9" (74 mm) 3.5" (89 mm) H822/H822-20 Dimensional Drawing 1.0" (26 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) H922 Dimensional Drawing 1.1" * (27 mm) Removable/Adjustable Mounting Bracket 0.7" (18 mm) 0.9" (23 mm) 2.8" * (71 mm) Removable Mounting Bracket 1.0" (25 mm) 1.1" (26 mm) 3.1"** (79 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris 0.4" x 0.2" Slot (x2) 1.7 (43 mm) 1.1" * (27 mm) Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" 3.0" (64 mm) (76 mm) 1.4"* (36 mm) 2.3" (58 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. ORDERING INFORMATION MODEL H622-10 H622-20 H722LC H722HC H822 H822-20 H922 H922030A H922060A H922120A AMPERAGE RANGE 0 to 10 A 0 to 20 A 0 to 10/20/40 A 0 to 50/100/200 A 0 to 10 A 0 to 20 A 0 to 30/60/120 A 0 to 30 A 0 to 60 A 0 to 120 A SENSOR OUTPUT HOUSING UL CE LEAD FREE Split-core · · Split-core · · Solid-core · · Solid-core · · Solid-core · · 0 to 5 Vdc Solid-core · · Split-core · 1 · Split-core · Split-core · Split-core · 1. Listed for use on 75°C insulated conductors. MOTOR Fan or Pump ACCESSORIES P. 279 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 266 Current Monitoring | Current Transducers: 0 to 10 Vdc Analog Output HX23 SERIES Load Trending with 0 to 10 Vdc Output Self-powered analog Self-powered analog current transducer 0 to 10 Vdc output No external power required No external power required for sensor Retrofit Factory calibrated Self-gripping, split-core design for fast retrofit installation...no need Factory calibrated ranges for high to remove conductor (H623-xx resolution and installation ease and H923) H723 H923 No jumpers Field-selectable No jumpers on unit...reduces ranges installation error Some models available with field- selectable ranges H623-xx TM Maximize Reliability Minimize Installed Cost The Hawkeye 623-xx, 723LC, 723HC, and 923 Series provide accurate load trending information with a proportional 0 to 10 Vdc output signal. Devices offer three amperage range options, with slide-switch selection for easy field adjustment no need for jumpers. APPLICATIONS · Load trending · Motor control · Fan/pump status EXAMPLE LINEAR OUTPUT Scale software as shown 10 V SENSOR OUTPUT SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Accuracy Response Time Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Induced from monitored current 600 Vac RMS (UL) (H623-xx) 300 Vac RMS (CE) (H623-xx , H723, H923) 50/60 Hz nominal -15 to 60 °C (5 to 140 °F) 10 to 90% RH, non-condensing ±2% F.S. from 10% to 100% (range) 2 sec. 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing (H623-xx only); CE: EN61010-1, CAT III, Pollution Degree 2, basic insulation 0 V 0 A Selected Range SENSED AMPS E150462 267 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com H623-XX Dimensional Drawing 2.1" (54 mm) Removable Mounting Bracket 0.6" (16 mm) 1.2" 0.7" (31 mm) (18 mm) 0.5" (13 mm) 2.5" (64 mm) 2.1" (54 mm) 0.4" x 0.2" (10 mm x 5 mm) Slot (2x) 2.9" (74 mm) 3.5" (89 mm) 1.0" (26 mm) H923 Dimensional Drawing Removable Mounting Bracket 1.1" (26 mm) 3.1"** (79 mm) 1.0" (25 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" 3.0" (64 mm) (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. Current Monitoring | Hx23 Series H723LC/H723HC Dimensional Drawing Removable/Adjustable Mounting Bracket 0.7" (19 mm) 0.9" (23 mm) 3.0" ** (75 mm) 0.2" x 0.15" slot (2x) 2.8" (68 mm) 3.8" (95 mm) 4.2" (106 mm) 1.1" * (27 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. MONITORING FAN/PUMP MOTORS FOR POSITIVE PROOF OF FLOW Wiring Diagram CONTROLLER AI COMMON 0 to 10 Vdc + CONTACTOR Fan or Pump ORDERING INFORMATION MODEL AMPERAGE RANGE SENSOR OUTPUT HOUSING UL CE H623-10 0 to 10 A Split-core · · H623-20 0 to 20 A Split-core · · H723LC 0 to 10/20/40 A 0 to 10 Vdc Solid-core · H723HC 0 to 50/100/200 A Solid-core · H923 0 to 20/100/150 A Split-core · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 268 Current Monitoring | Current Transducers with Relay: 4 to 20 mA Analog Output H931 Load Trending and Control Relay in One Package Loop-powered Loop-powered analog current transducer with integral start/stop command relay Reduces installation charges One device to install for start/stop and status Saves time Reduces the number of installed components...saves time and space Fewer wires Power the current sensor and receive the 4 to 20 mA signal with only two wires Maximize Reliability Minimize Installed Cost H931 TM Retrofit Self-gripping, split-core design for fast retrofit installation...no need to remove conductor Factory calibrated Selectable factory calibrated ranges up to 120 A for increased flexibility and resolution The Hawkeye 931 provides accurate load trending information with a proportional 4 to 20 mA output signal. These devices offer three amperage ranges for versatility, with easy slide-switch selection. The command relay is fully integrated in the device, but it is isolated from the current transducer. This combination makes these products ideal for start/stop control and status monitoring of motors, using one device instead of two. APPLICATIONS · Load trending · Motor control · Positive proof of flow SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Accuracy Response Time Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 30 mA (max.) @ 12 to 30 Vdc 600 Vac RMS 50/60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing ±2% F.S. from 10% to 100% (selected range) 2 sec. 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation EXAMPLE LINEAR OUTPUT Scale software as shown 5 V SENSOR OUTPUT 0 V 0 A 30/60/120 A* SENSED AMPS *Factory calibrated ranges selected with the amperage range switch E150462 Note: Do not use LED status indicators as evidence of applied voltage 269 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com DIMENSIONAL DRAWING Removable Mounting Bracket 1.1" (26 mm) 3.1"** (79 mm) 1.0" (25 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" (64 mm) 3.0" (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. Current Monitoring | H931 TRENDING & CONTROLLING MOTOR LOADS Wiring Diagram 12 to 30 Vdc Power Source CONTROLLER Analog Input (4 to 20 mA) Digital Output (Relay Coil) CONTACTOR CONTROL POWER Fan or Pump Motor RELAY CONTACT RATINGS (N.O.) Resistive 5 A @ 250 Vac, 30 Vdc 5 A @ 30 Vac, 30 Vdc Inductive 2 A @ 250 Vac, 30 Vdc 2 A @ 30 Vac, 30 Vdc TYPICAL COIL PERFORMANCE Voltage AC DC 24 15 15 ORDERING INFORMATION MODEL H931 AMPERAGE RANGE 0 to 30/60/120 A SENSOR OUTPUT 4 to 20 mA RELAY TYPE SPST, N.O. RELAY COIL 24 Vac/dc RELAY RELAY POWER LED UL · · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 270 Current Monitoring | Current Transducers with Relay: 0 to 5 Vdc Analog Output H932 & H952 Load Trending and Control Relay in One Package H932 TM Maximize Reliability Minimize Installed Cost The Hawkeye 932 and 952 Series provide accurate load trending information with a proportional 0 to 5 Vdc output signal. This feature combined with an integrated command relay makes these products ideal for start/stop and status monitoring of motors. The relay is fully isolated from the current sensor, and all relay connections are externally available for maximum flexibility. Self-powered Self-powered analog current transducer with integral start/stop command relay Reduces installation One device to install for start/stop and status Saves time Reduces the number of installed components...saves time and space No external power No external power required for current sensor Retrofit Self-gripping, split-core design for fast retrofit installation...no need to remove conductor Increased flexibility Selectable factory calibrated ranges up to 120 A for increased flexibility and resolution APPLICATIONS · Load trending · Motor control · Fan/pump status EXAMPLE LINEAR OUTPUT Scale software as shown 5 V SENSOR OUTPUT SPECIFICATIONS Sensor Power Insulation Class Frequency Range Temperature Range Humidity Range Accuracy Response Time Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Induced from monitored conductor 600 Vac RMS 50/60 Hz -15 to 60 °C (5 to 140 °F) 10 to 90% RH non-condensing ±2% F.S. from 10% to 100% (selected range) 2 sec. 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation 0 V 0 A 30/60/120 A* SENSED AMPS *Factory calibrated ranges selected with the amperage range switch E150462 Note: Do not use LED status indicators as evidence of applied voltage 271 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | H932 & H952 H932/H952 Dimensional Drawing Removable Mounting Bracket 1.0" (25 mm) 1.1" (26 mm) 3.1"** (79 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" (64 mm) 3.0" (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. RELAY CONTACT RATINGS (N.O.) Resistive 5 A @ 250 Vac, 30 Vdc 5 A @ 30 Vac, 30 Vdc Inductive 2 A @ 250 Vac, 30 Vdc 2 A @ 30 Vac, 30 Vdc TYPICAL COIL PERFORMANCE Voltage AC DC 24 (H932) 15 15 12 (H952) 20 Pull In Voltage (H952 only) 12 Vdc 8.4 Vdc Drop Out Voltage (H952 only) 12 Vdc 3.0 Vdc TRENDING & CONTROLLING MOTOR LOADS WITH THE HAWKEYE 932 Wiring Diagram CONTROLLER Digital Output (Relay Coil) Analog Input (0 to 5 Vdc) CONTROL POWER CONTACTOR Fan or Pump Motor ORDERING INFORMATION MODEL H932 H952 AMPERAGE RANGE 0 to 30/60/120 A SENSOR OUTPUT 0 to 5 Vdc RELAY TYPE SPST, N.O. RELAY COIL 24 Vac/dc 12 Vdc HOUSING UL · Split-core · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 272 Current Monitoring | Direct Current Transducers: Split-Core, 4 to 20 mA Output H971 & EA20 SERIES DC Applications pulse reset technologyTM U.S. Pat. #6,160,697; 6,522,517; 7,242,157 Retrofit Self-gripping iris for easy installation HOA Bi-directional model...useradjustable span from ±20 to ±200 A (H971) Flexibility Bracket can be installed in three different configurations Status LED Status LED ensures proper wiring TM H971 Hawkeye DC Transducers provide accurate load level monitoring of DC loads. The H971 and EA20 use Pulse Reset TechnologyTM with field proven circuitry to provide a superior solution for DC applications with minimal risk of permanent magnetization, providing longer life and better accuracy. The EA20 and the H971 have 4 to 20 mA output only. The H971 also offers bi-directional sensing capability and a user-adjustable span to allow greater application flexibility. Pulse Reset TechnologyTM Patented Pulse Reset Technology significantly increases accuracy... sensor is not affected by stray magnetic fields, minimize magnetization from over-current faults 100, 150 and 200 Amp span 100, 150, and 200 A versions available...application flexibility (EA20 uni-directional model) APPLICATIONS · Battery chargers · Motor armature current · Motor field current · Automotive loads · Marine equipment · Solar energy applications · Telecom · Electroplating SPECIFICATIONS System Technology Amperage Range Sensor Supply Voltage Supply Current Insulation Class Temperature Range Humidity Range Output Terminal Block Wire Size Terminal Block Torque Response Time ACCURACY Accuracy at Ranges Below 100 A Accuracy at Ranges Above 100 A Withstand Current WARRANTY Limited Warranty Exclusive Pulse Reset TechnologyTM H971: ±200 ADC; EA20: 0 to 100 ADC/0 to 150 ADC/0 to 200 ADC 12 to 24 Vdc1 35 mA2 H971: 600 Vdc, EA20: 1000 Vdc -30 to 60 °C (-22 to 140 °F) 10 to 90% RH non-condensing H971: Bidirectional 4 to 20mA (adjust. span)3; EA20: Unidirectional 4 to 20 mA 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) Less than 150 msec AGENCY APPROVALS Agency Approvals CE 4: EN61010-1, CAT III, Pollution Degree 2, basic insulation Note: Do not use the LED status indicators as evidence of applied voltage. 1. For currents over 120A, supply voltage must be at least 15V. 2. For H971, at zero monitored current: 35mA max.; at 200A monitored current: 55mA to 100mA depending on supply voltage and current polarity. 3. Unless factory set per customer specifications (H971SP only). 4. For single conductor through product (no wraps). ±0.5 A (combined linearity, hysteresis, and repeatability)5 ±0.5% full scale (combined linearity, hysteresis, and repeatability)4 25,000 ADC 5 years 273 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | H971 & EA20 Series H932/H952 Dimensional Drawing Removable Mounting Bracket 1.0" (25 mm) 1.1" (26 mm) 3.1"** (79 mm) 0.8" (21 mm) Bracket can be mounted on three sides for added installation flexibility. Self-gripping Iris Ø 0.3" (8 mm) 2.8" (70 mm) 2.5" (64 mm) 3.0" (76 mm) 1.4"* (36 mm) * Terminal block may extend up to 1/8" over the height dimensions shown. ** Slide switch may extend up to 1/4" over the height dimensions shown. EA20 LINEAR OUTPUT Scale software as shown 20 mA SENSOR OUTPUT 4 mA 0 A SENSED AMPS EA20: 100/150/200 A H971 BIDIRECTIONAL OUTPUT Scale software as shown 20 mA 12 mA H971/EA20 Wiring Diagram CONTROLLER 4 to 20 mA Ground Sensor Supply DC Load 200ADC C u r r 97 en 1 tS e n s o r V E P R IS o r tl a nI Nd ,DOUr eSg1To- 8Rn 0I90E7-S23 23 54 - 8 5 5 6 ! Current Flow 4-20 mA 12-24 Gnd VDC Power Span CONTACTOR SENSOR OUTPUT 4 mA -200 A1 0 A +200 A1 SENSED AMPS 1. Field Adjustable from ±20 A to ±200 A (not applicable to customer-specified factory scaled models) ORDERING INFORMATION MODEL PULSE RESET TECHNOLOGY AMPERAGE RANGE (DC) SENSOR OUTPUT HOUSING STATUS LED UL CE ROHS Hawkeye Series H971 · 0 to 200 A Bidirectional 4 to 20 mA Split-core · · · · H971SP · 0 to 200 A1 Bidirectional 4 to 20 mA Split-core · · · · EA Series EA20BB010 · 0 to 100 A Unidirectional 4 to 20 mA Split-core · · 2 · · EA20BB015 · 0 to 150A Unidirectional 4 to 20 mA Split-core · · 2 · · EA20BB020 · 0 to 200A Unidirectional 4 to 20 mA Split-core · · 2 · · 1. Range set in factory per customer specified value from 0 to ±20 A through 0 to ±199 A. 2. UL Recognized. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 274 Current Monitoring | Field Mount Motor Control Device H5XX SERIES Combination Switching Relay, Current Status Switch, and HOA Switch* Remote mounted HOA Remote mounted current status sensor* and command relay with or without HOA switch HOA provides true relay control... ideal for troubleshooting control wiring Status sensor Combines status sensor,* command relay, and HOA switch in a single series circuit...one line connection for three devices SPST SPST relay is field-selectable for N.O. or N.C. operation Gang box mounting Mounts directly onto gang box, flush to existing enclosures and standalone Maximize Reliability Minimize Installed Cost The Hawkeye 5xx Series combines an industrial grade load-switching relay, current status switch*, and Hand-Off-Auto (HOA) switch* in an easy-to-install remote enclosure, making the series ideal for monitoring, directly controlling, and troubleshooting the control wiring of fractional horsepower motors. In some models, the relay, current sensor, and HOA switch are combined in a series circuit. Once an H5xx is wired in series between the power source and motor, all three components are installed. The housing provides physical separation and multiple wiring exits to isolate control and high voltage wiring. An H5xx can be mounted directly on 2- or 4-gang junction boxes, nippled to a field enclosure, or stand alone. APPLICATIONS · Monitoring status and controlling small motor loads that are not driven by a motor starter or contactor · Exhaust fans Up to 1 HP All models rated up to 1 HP @ 120 Vac, NS Versions 1 HP @ 120 Vac and 1.5 HP @ 277 Vac...one product for all fractional HP motor control and status applications · Unit ventilators · Fan terminal units · Fan coil units · Recirculating pumps SPECIFICATIONS Sensor Power Frequency Range Humidity Range Temperature Range Terminal Block Wire Size Terminal Block Torque WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals Induced from monitored conductor 50/60 Hz 10 to 90% RH non-condensing -15 to 50 °C (5 to 122 °F) 24 to 14 AWG (0.2 to 2.1 mm2) 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m) 5 years UL 508 closed type device listing, CAT III, Pollution Degree 2, basic insulation RELAY CONTACT RATINGS SPDT (NS) Models Resistive 15 A @ 277 Vac Motor 1 HP @ 120 Vac 1.5 HP @ 277 Vac SPST (HOA) Models Resistive 15 A @ 250 Vac Motor 1 HP @ 120 Vac TYPICAL COIL PERFORMANCE Voltage AC DC 24 V 36 mA 36 mA E150462 *Some models 275 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | H5xx Series DIMENSIONAL DRAWING Wire Opening (Low Voltage Only) CL 1.2" (30 mm) 4.25" (108 mm) Wire Opening CL 1.16" (30 mm) 4.25" (108 mm) WIRING DIAGRAM Wire Opening CL 2.2" (55 mm) 1.6" (39 mm) POWER SOURCE IN SERIES CURRENT SENSOR EXHAUST FAN CONTROLLER DIGITAL OUT 24 V STATUS IN HOA SWITCH MOUNTS DIRECTLY ON 4-GANG JUNCTION BOX Mounting Options Low Voltage Wires Only 1/2" Conduit Fitting Line Voltage Wires MOUNTS DIRECTLY ON 2-GANG JUNCTION BOX Mounting Options Low Voltage Wires Only RS Line Voltage OC SO Wires SP SC MOUNTS DIRECTLY ON WALL OR PANEL Mounting Options Low Voltage Wires Only 1/2" Conduit Fitting Line Voltage Wires ENCLOSURE MOUNT Status Output & Relay Coil (Low Voltage Wires Only) Nipple to Existing Enclosures ENCLOSURE RELAY = CIRCUIT PATH ORDERING INFORMATION MODEL AMPERAGE RANGE STATUS OUTPUT TRIP POINT H535 H535NS H540 0.25 to 15A 0.25 to 15 A 0.25 to 15 A H540NS 0.25 to 15 A H548 0.5 to 15 A H548NS 0.5 to 15 A Relay Only Relay Only N. O., 1.0 A @ 30 Vac/dc N. O., 1.0A @ 30 Vac/dc N. O., 1.0A @ 30 Vac/dc N. O., 1.0 A @ 30 Vac/dc 0.25 A or Less, Fixed 0.25 A or Less, Fixed 0.5 A or Less, Adjustable 0.5 A or Less, Adjustable RELAY SPST, Field-Selectable N.O/N.C. SPDT SPST, Field-Selectable N.O/N.C SPDT SPST, Field-Selectable N.O/N.C SPDT RELAY COIL HOA STATUS SWITCH LEDS RELAY POWER LED UL · · · · · · 24 Vac/dc · · · · · · · · · · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 276 Current Monitoring | Field Mount Status Relay H120 SERIES SPST Status Relay with Integral Current Switch 2-in-1 HP ratings Current switch and relay are in series...connect the contacts to the load and your current switch is automatically installed HP ratings make the H120 ideal for control and status of fractional HP motors Nipple mount 0.1A turn-on The nipple mount housing can Easily monitors the smallest loads be connected to any 1/2" conduit knockout for installation versatility Relay coil LED NEMA 1 rated TM Relay coil LED streamlines job NEMA 1 rated housing may be commissioning and check out used in plenum spaces The H120 and H120NC offer a fixed current switch and SPST relay in a single externally mounted housing. Combining the current sensor and relay in one easy-to-install package eliminates the need to fit multiple devices into small electrical enclosures and simplifies the installation. Remove the labor associated with installing a separate current sensor. APPLICATIONS · Unit ventilators · Fan coil units · Exhaust fans SPECIFICATIONS Sensor Power Induced from relay coil power Operating Temperature -15 to 60 °C (5 to 140 °F) (13.8 A max.), -15 to 50 °C (5 to 12 °F) (2 A max.) Frequency Range 50/60 Hz Operating Humidity 10 to 90% RH non-condensing Expected Relay Life (mechanical) 10 million cycles Relay Status LED ON=energized LEAD WIRE SPECIFICATIONS Lead Length 14" (356 mm) min. Style and Gauge UL1015; Coil: 18 AWG; Contacts: 12 AWG; Status: 16 AWG WARRANTY Limited Warranty 5 years AGENCY APPROVALS Agency Approvals UL 508 closed type device listing, CAT III, Pollution Degree 2, basic insulation E150462 Note: Do not use the LED status indicators as evidence of applied voltage. · Fan terminal units · Fractional HP motors · Light resistive loads 277 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NIPPLE MOUNT DIRECTLY TO A PANEL Wiring Diagrams Current Monitoring | H120 Series DIMENSIONAL DRAWING NIPPLE MOUNT TO 4X ELECTRICAL BOX Wiring Diagrams WIRE COLOR CODES RELAY CONTACT RATINGS Resistive 20 A (r)· @ 277 Vac/28Vdc (250,00 Cycles) Motor 120 Vac, 1HP 208 Vac, 1HP 250 Vac, 2HP 277 Vac, 2HP Ballast 277 Vac, 20 A Tungsten 120 Vac, 10 A TYPICAL COIL PERFORMANCE Voltage Coil Current AC DC 24V 75 mA 32 mA *See operating temperature specifications ORDERING INFORMATION MODEL H120 H120NC AMPERAGE RANGE 0.1 to 20 A COIL RELAY STATUS OUTPUT TRIP POINT HOUSING RELAY POWER LED UL N.O. 100 mA @ 30 Vac/dc · · 24 Vac/dc SPST, N.O. 0.1 A or Less Nipple Mount N.C. 100 mA @ 30 Vac/dc · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 279 278 Hx00 Hx08 & H701 Hx09 Hx06 H11D H10F H614 H904, H934, H720 H6ECM Hx30/40/50 H735, Hx38, Hx48, Hx58 Hx39, Hx49, Hx59 H721xC & H921 Hx21 & Hx21SP Hx22 H723xC & H923 H931 & H 951 H932 & H952 H971 & EA20 Current Monitoring | Accessories ACCESSORIES SELECTION GUIDE: CURRENT MONITORING Product Description AH01 DIN Rail Clip Set AH06 CT Mounting Brackets AH27 DIN Rail Clip Set AV01 35 mm DIN Rail - 1 Meter Length AV02 DIN Rail Stop Clip PS Universal Power Supply 1. For H6xx, H8xx, H9xx. 2. For H3xx. ·1 ·1 · · · · · · · · · · · ····· · ·2 ·2 ············· ····· ············· ····· · AH01 DIN Rail Clip Set AH06 CT Mounting Brackets AH27 DIN Rail Clip Set AV02 DIN Rail Stop Clip PS Universal Power Supply AV01 35 mm DIN Rail - 1 Meter Length 279 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Current Monitoring | Accessories 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 280 RELAYS Veris offers a complete line of relays for motor control, relay logic, and other automation system applications. Nipple mount, DIN mount and other options are all available. MODEL V100/200 V101/102/103 and V201 V300/400 V120/V220 V121/122/123 and V221/222/223 V320/V420 V321/V421 V645 VMD1B VMD2B VMD3B VMD4B VS861 VTD DESCRIPTION 10 A SPDT Enclosed Relay10 A@277 Vac, 28 Vdc 10 A SPST Enclosed Relay with HOA Switch 10 A@250 Vac or 277 Vac 10 A DPDT Enclosed Relay10 A@277 Vac, 30 Vdc 20 A SPDT Enclosed Relay 20 A@277 Vac, 28 Vdc 20 A SPST Enclosed Relay with HOA Switch 20 A@240 Vac, 8 A@28 Vdc 20 A DPDT Enclosed Relay 20 A@277 Vac, 28 Vdc 20 A DPST Enclosed Relay with HOA Switch 20 A@240 Vac or 8 A@240 Vdc 10 A SPDT Enclosed Mini Command Relay 10 A@250 Vac N.O., 7 A@250 Vac N.C. Socket SPDT Relays Socket DPDT Relays Socket 3PDT Relays Socket 4PDT Relays Solid State Relays Time Delay Relays PAGE 285 287 289 291 293 295 297 299 301 303 305 307 309 311 281 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com RELAY SELECTION GUIDE RELAYS AND SOCKETS APPLICATIONS SPDT 10A SPDT 20A DPDT 10A DPDT 20A 3PDT 15A 4PDT 15A Time Delay 12A Solid State 8A * Indicates a series of products. NIPPLE MOUNT V100*/V200* page 285 V120/V220 page 291 V300/V400 page 289 V320/V420 page 295 SOCKET MOUNT VMB1B-S* (3A) page 301 VMD1B-C*/VMD1B-F* page 301 VMD2B-S* page 303 VMD2B-C*/VMD2B-F* page 303 VMD3B-C*/VMD3B-F* page 305 VMD4B-C*/VMD4BF* page 307 VTD2P-F50 page 311 DIN MOUNT V645, VMB1B-S* (3A) pages page 299, page 301 VMD1B-C*/VMD1B-F* page 301 VMD2B-S* page 303 VMD2B-C*/VMD2B-F* page 303 VMD3B-C*/VMD3B-F* page 305 VMD4B-C*/VMD4BF* page 307 VTD1P-UNI/VTD2P-UNI page 311 VS861* page 309 RELAYS WITH HOA SWITCH APPLICATIONS SPST 10A NO HOA MONITORING V101*/V201* page 287 SPST 20A V121/V221 page 293 DPST 20A V321/V421 page 295 * Indicates a series of products. RESISTIVE HOA MONITORING V102 page 287 V122/V222 page 293 DIGITAL HOA MONITORING V103 page 287 V123/V223 page 293 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 282 REDUCE COSTS WITH QUICK AND EASY MOUNTING Victory Enclosed Relays APPLICATIONS » Command contactors » Control motors » Isolation » Device interlocking » Relay logic » Sense voltages for alarm conditions FEATURES SAVES DEBUG TIME Local control and troubleshooting with HOA switch available SAVES LABOR Flying leads for exceptional time and labor savings QUICK MOUNTING With nipple mount feature for common electrical box enclosures 283 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com SAVE TIME, COSTS WITH SIMPLIFIED INSTALLATION, MAINTENANCE DIN Mount Socket Relays APPLICATIONS » In panel » Panel or DIN rail mount » Command contactors » Control motors » Device interlocking » Relay logic FEATURES MANUALLY OVERRIDE Relay with override lever, providing control at the relay TEST BUTTON Push to test button, activate relay to commission job CONTACT FLAG For easy troubleshooting with visual confirmation, eliminates guesswork and saves time HOLD-DOWN CLIP Available with marking surface for tidy installation 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 284 Relays | Enclosed Victory Relays: 10 A SPDT VICTORY 100 & 200 SERIES Great for External Mount Applications V200D V100 Sleek enclosure Reduces the need for panel space UL508 Listed Designed and listed for field installation...makes electrical inspection a snap Nipple mount Victory Series products can be mounted to any electrical enclosure, easing installation Eliminate conduit Run low voltage instead of line voltage...eliminates conduit in some applications Flexible wire Flexible tinned stranded wire... fits easily in tight spaces, provides secure connections to wire nuts Victory 100 and 200 Series 10 A enclosed relays are pilot-duty relays in an easy-to-use nipple mount enclosure. The V100/V200 Series provide quick relay mounting without a dedicated field enclosure, making them ideal for retrofit projects. Field-selectable high and low voltage coil inputs provide on-site versatility. SPECIFICATIONS Operating Humidity Range 10 to 90% RH non-condensing Expected Relay Life Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles Relay Status LED ON=energized Insulation Class 600 Vac RMS OPERATING TEMPERATURE RANGE V100, V100DC, V200 -34 to 60 °C (-29 to 140 °F) V100D, V200D -40 to 55 °C (-40 to 131 °F) Wire Specifications Lead Length 14" (356 mm) min. Gauge UL1015; Coil: 18 AWG; Contacts: 16 AWG WARRANTY Limited Warranty 5 years AGENCY APPROVALS Agency Approvals UL 508 E150462 APPLICATIONS · Command contactors · Control motors · Isolation · Device interlocking · Relay logic · Sense voltages for alarm conditions TYPICAL COIL PERFORMANCE Pull in Voltage AC DC 10 to 30 V 8 9 120 V 78 208 to 277 V 154 Drop Out Voltage 10 to 30 V 2 3 120 V 18 208 to 277 V 36 Voltage Coil Current AC DC 10 V 25 mA 14 mA 12 V 25 mA 14 mA 24 V 31 mA 16 mA 30 V 39 mA 18 mA 120 V 22 mA 208 V 19 mA 277 V 25A CONTACT RATINGS Resistive 10 A @ 277 Vac, 28 Vdc Motor 120 Vac, 1/3 HP N.O. & 1/6 HP N.C. 240 Vac, 1/3 HP N.O. & 1/6 HP N.C 277 Vac, 1/4 HP N.O. * 1/8 HP N.C. Pilot Duty 277 Vac (1.7 A), 480 VA N.O. Ballast 277 Vac, 1.7 A Tugsten 120 Vac, TV3 N.O. TV2 N.C. Gold Flash yes 285 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NIPPLE MOUNT DIRECTLY TO A PANEL Wiring Diagram Relays | Victory 100 & 200 Series V100/V100DC/V200 Dimensional Drawing 2.9" (74 mm) NIPPLE MOUNT TO ANY 2X OR 4X ELECTRICAL BOX Wiring Diagram To Load CONTACTS COIL Wire Nut To Controls 2.8" (71 mm) 1.6" (41 mm) 1.7" (43 mm) 1.8" (46 mm) V100D/V200D Dimensional Drawing 4.0" (103 mm) 1/2" NPT Nipple 3.8" (97 mm) 2.0" (52 mm) 2.3" (59 mm) 2.5" (64 mm) 3/4" NPT Nipple PRIMARY Wire Color Codes CONTROL SYSTEM INPUT HI wht/brown HI wht/black black brown White 208 to 277 Vac White 120 Vac black brown or * LOW wht/blue COMM wht/yellow yellow blue White 10 to 30 Vac/dc White Common yellow blue *Isolation...600 Vac CONTACT OUTPUT BLUE N.C. YELLOW Common ORANGE N.O. RELAY 2 ON V100D AND V200D ONLY Wire Color Codes CONTROL SYSTEM INPUT HI wht/orange HI wht/red red orange White 208 to 277 Vac White 120 Vac red orange or * LOW grey/wht COMM wht/violet violet white Grey 10 to 30 Vac/dc White Common violet white *Isolation...600 Vac CONTACT OUTPUT GREY N.C. VIOLET Common BROWN N.O. ORDERING INFORMATION MODEL RELAY COIL AMPERAGE RATING RELAY POWER LED UL V100* SPDT 10 to 30 Vac/dc, 120 Vac · · V100D 2x SPDT 10 to 30 Vac/dc, 120 Vac · · V100DC SPDT 10 to 30 Vdc 10 A · · V200 SPDT 10 to 30 Vac/dc, 208 to 277 Vac · · V200D 2x SPDT 10 to 30 Vac/dc, 208 to 277 Vac · · Note: Some units are Plenum rated per UL 1995. For details, see White Paper VWP01, UL 1995 and Plenum Ratings, at www.veris.com. *U.S. origin version available. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 286 Relays | Enclosed Victory Relays: 10 A SPST with HOA Switches VICTORY 101, 102 & 103 SERIES Relays with HOA Switches for Local Control Nipple mount Can be mounted to any electrical enclosure, easing installation Flexible wire Flexible tinned stranded wire... fits easily in tight spaces, provides secure connections to wire nuts Cover conceals HOA switch V101D/ V201D V101/V201 Protective cover Conceals and protects the HOA switch, reducing the likelihood of tampering UL508 Listed Designed and listed for field installation...makes electrical inspection a snap Sleek enclosure Reduces the need for panel space Switch position monitors Allows the control system to notify personnel when a load is inadvertently left ON or OFF (V102 and V103 models) V102 With a concealed HOA switch for local control and troubleshooting, the Victory 101, 102, and 103 Series relays provide HOA flexibility while limiting unauthorized switch manipulation. To further guard against control system override, some relays are equipped with a monitored HOA. The V102 provides a two-wire resistive output and the V103 offers a three-wire digital monitor. Now your customers and technicians can enjoy the benefit of local control without the problems often caused by override. SPECIFICATIONS Operating Temp Range -40 to 55 °C (-40 to 131 °F) Operating Humidity Range 10 to 90% RH non-condensing Expected Relay Life Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles Relay Status LED ON=energized Insulation Class 600 Vac RMS WIRE SPECIFICATIONS Lead Length 14" (356 mm) min. Gauge UL1015; Coil: 18 AWG; Contacts: 16 AWG; HOA monitor wires: 16 AWG V102 RESISTIVE MONITOR MAXIMUMS Voltage Max. 13.4 Vac/dc Current Max. 4mA AC/DC V103 Digital Monitor Maximums Dry Circuit Contact Rating (Max.) 24 Vac/dc@100 mA WARRANTY Limited Warranty 5 years APPLICATIONS · Command contactors · Control motors · Isolation · Device interlocking · Relay logic · Sense voltages for alarm conditions TYPICAL COIL PERFORMANCE Pull in Voltage AC DC 10 to 30 V 8 9 120 V 78 208 to 277 V 154 Drop Out Voltage 10 to 30 V 2 3 120 V 18 208 to 277 V 36 Voltage Coil Current AC DC 10 V 25 mA 14 mA 24 V 31 mA 16 mA 30 V 39 mA 18 mA 120 V 22 mA 208 V 19 mA 277 V 25A CONTACT RATINGS V101, V201, V101D*, V201D* Resistive 10 A @ 250 Vac Motor 1/3 HP @ 120Vac Gold Flash Yes V101, V201, V101D*, V201D* Resistive 10 A @ 277 Vac Motor 1/3 HP @ 240 Vac Gold Flash Yes *each relay AGENCY APPROVALS Agency Approvals UL 508 E150462 287 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Relays | Victory 101, 102, & 103 Series NIPPLE MOUNT DIRECTLY TO A PANEL Wiring Diagram V102 DIMENSIONAL DRAWING 4.0" (103 mm) RESISTIVE INPUT DO NIPPLE MOUNT TO ANY 2X OR 4X ELECTRICAL BOX Wiring Diagram To Load CONTACTS COIL Wire Nut To Controls 3.8" (97 mm) 2.0" (52 mm) 2.3" (59 mm) 2.5" (64 mm) 3/4" NPT Nipple PRIMARY Wire Color Codes CONTROL SYSTEM INPUT brown brown HI White wht/brown 208 to 277 Vac or black HI wht/black black White 120 Vac HOA Switch Hand Off LOW wht/blue COMM wht/yellow yellow blue White 10 to 30 Vac/dc White Common yellow blue Auto *600 Vac Isolation CONTACT OUTPUT ORANGE ORANGE V103 DIGITAL HOA POSITION MONITOR Wire Color Codes HAND OFF AUTO BROWN BROWN BROWN VIOLET VIOLET VIOLET RELAY #2 FOR V101D/V201D ONLY Wire Color Codes CONTROL SYSTEM INPUT HI (201D) HOA Switch orange wht/orange orange White HI (101D) wht/red red 208 to 277 Vac WWhhitiete 120 Vac red or Hand * Off LOW grey/wht COMM wht/violet violet white Grey 10 to 30 Vac/dc White Common violet white Auto *600 Vac Isolation CONTACT OUTPUT BROWN BROWN V102 RESISTIVE HOA POSITION MONITOR Switch Positions: Cable Faults: GREY HAND ~ 1.4 k OPEN = Infinite OFF ~ 6.2 k SHORT ~ 0 AUTO ~ 3.4 k GREY GREY Switch Positions: HAND = Brown wire closed to Common OFF = Both wires open to Common GREY GREY AUTO = Grey wire closed to Common VIOLET = Common ORDERING INFORMATION MODEL RELAY COIL AMPERAGE RATING HOA HOA MONITOR RELAY POWER LED UL V101 SPST, N.O. 10 to 30 Vac/dc, 120 Vac V101D 2x SPST, N.O. 10 to 30 Vac/dc, 120 Vac V102 SPST, N.O. 10 to 30 Vac/dc, 120 Vac 10 A V103 SPST, N.O. 10 to 30 Vac/dc, 120 Vac V201 SPST, N.O. 10 to 30 Vac/dc, 208 to 277 Vac V201D 2x SPST, N.O. 10 to 30 Vac/dc, 208 to 277 Vac · None · None · Resistive · Digital · None · None · · · · · · · · · · · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 288 Relays | Enclosed Victory Relays: 10 A DPDT VICTORY 300 & 400 DPDT Relays Provide Versatility V300 Nipple mount Can be mounted to any electrical enclosure, easing installation Flexible wire Flexible tinned stranded wire... fits easily in tight spaces and provides secure connections to wire nuts Sleek enclosure Reduces the need for panel space UL508 Listed Designed and listed for field installation...makes electrical inspection a snap V400 The Victory 300 and 400 Series 10A DPDT pilot duty enclosed relays combine industrial strength and ease of use. The nipple mount enclosure makes installation easy. With no need for a dedicated field enclosure, they are the ideal retrofit devices. One coil input controls the state of two pilot rated contacts for the simultaneous control of two devices or both poles of a single-phase circuit, e.g. motor loads. Fieldselectable high and low voltage coil inputs provide on-site versatility. APPLICATIONS · Command contactors · Control motors · Isolation · Device interlocking · Relay logic · Sense voltages for alarm conditions Resistive Motor CONTACT RATINGS 10 A total of both poles, 250 Vac & 28 Vdc 1/8 HP @ 120 Vac SPECIFICATIONS Operating Temp Range Operating Humidity Range Expected Relay Life Relay Status Insulation Class WIRE SPECIFICATIONS Lead Length Gauge WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals -34 to 60 °C (-29 to 140 °F) 10 to 90% RH non-condensing Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles LED ON=energized 600 Vac RMS 14" (356 mm) min. UL1015; Coil: 18 AWG; Contacts: 16 AWG 5 years UL 508 E1E15500446622 289 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NIPPLE MOUNT DIRECTLY TO A PANEL Wiring Diagram To Load CONTACTS COIL To Controls CONTROL PANEL NIPPLE MOUNT TO ANY 2X OR 4X ELECTRICAL BOX Wiring Diagram Contacts To Load CONTACTS To Load COIL Wire Nut To Controls Relays | Victory 300 & 400 DIMENSIONAL DRAWING 2.9" (74 mm) 2.8" (71 mm) 1.6" (41 mm) 1.7" (43 mm) 1.8" (46 mm) 1/2" NPT Nipple WIRE COLOR CODES CONTROL SYSTEM INPUT brown brown HI White wht/brown 208 to 277 Vac or black HI wht/black black White 120 Vac * blue LOW wht/blue blue White 20 to 30 Vac/dc COMM wht/yellow yellow White Common yellow *Isolation...600 Vac CONTACT OUTPUT BLUE N.C. #1 YELLOW Common #1 ORANGE GREY VIOLET N.O. #1 N.C. #2 Common #2 BROWN N.O. #2 ORDERING INFORMATION MODEL RELAY COIL AMPERAGE RATING RELAY POWER LED UL V300 20 to 30 Vac/dc,120 Vac V400 DPDT 20 to 30 Vac/dc, 208 to 277 Vac 10 A · · · · Note: Some units are Plenum rated per UL 1995. For details, see White Paper VWP01, UL 1995 and Plenum Ratings, at www.veris.com. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 290 Relays | Enclosed Victory Relays: 20 A SPDT VICTORY 120 & 220 Great for External Mount Applications V120 V220 Nipple mount Can be mounted to any electrical enclosure, easing installation Flexible wire Flexible tinned stranded wire... fits easily in tight spaces and provides secure connections to wire nuts HP ratings Ideal for control of fractional HP motors UL508 Listed Designed and listed for field installation...makes electrical inspection a snap Sleek enclosure Reduces the need for panel space The Victory 120 and 220 20 A SPDT enclosed relays combine a power duty relay with a high level of field-selectability and versatility. The devices are quick and easy to install using the threaded nipple mount. With no need for a dedicated field enclosure, this series is ideal for retrofit projects. SPECIFICATIONS Operating Temp. Range Operating Humidity Range Expected Relay Life Relay Status Insulation Class WIRE SPECIFICATIONS Lead Length Gauge WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals -34 to 55 °C (-29 to 131 °F) 10 to 90% RH non-condensing Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles LED ON=energized 600 Vac RMS 14" (356 mm) min. UL1015; Coil: 18 AWG; Contacts: 12 AWG 5 years UL 508 APPLICATIONS · Command contactors · Control motors · Isolation · Device interlocking · Relay logic · Sense voltages for alarm conditions TYPICAL COIL PERFORMANCE Voltage Coil Current AC DC 24 V 75 mA 32 mA 120 V 42 mA 208 V 36 mA 277 V 49 mA CONTACT RATINGS Resistive 20 A @ 277 Vac, 28 Vdc Motor 120 Vac, 1 HP 277, 2 HP Pilot Duty A300 Ballast 277 Vac, 20 A N.O. 277 Vac, 10 A N.O. Tungsten 120 Vac, 10 A N.O. 120 Vac, 2 A N.O. E150462 291 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NIPPLE MOUNT DIRECTLY TO A PANEL Wiring Diagram Relays | Victory 120 & 220 DIMENSIONAL DRAWING 2.9" (74 mm) NIPPLE MOUNT TO A 4X ELECTRICAL BOX Wiring Diagram POWER SOURCE To Controls Fractional HP Motor WIRE COLOR CODES CONTROL SYSTEM INPUT HI wht/brown brown White brown 208 to 277 Vac or black HI wht/black black White 120 Vac * LOW wht/blue COMM wht/yellow yellow blue White 24 Vac/dc White Common yellow blue *Isolation...600 Vac CONTACT OUTPUT BLUE N.C. YELLOW Common ORANGE N.O. 2.8" (71 mm) 1.6" (41 mm) 1.7" (43 mm) 1.8" (46 mm) 1/2" NPT Nipple ORDERING INFORMATION MODEL RELAY COIL AMPERAGE RATING RELAY POWER LED UL V120 24 Vac/dc, 120 Vac SPDT 20 A V220 24 Vac/dc, 208 to 277 Vac · · · · Note: Some units are Plenum rated per UL 1995. For details, see White Paper VWP01, UL 1995 and Plenum Ratings, at www.veris.com. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 292 Relays | Enclosed Victory Relays: 20 A SPST with HOA Switch VICTORY 121, 122, & 123 SERIES HOA Switch Provides Local Control V121/221 V122/222 Cover conceals HOA switch Protective cover Conceals and protects the HOA switch, reducing the likelihood of tampering Flexible wire Flexible tinned stranded wire... fits easily in tight spaces and provides secure connections to wire nuts Nipple mount Allows the V121 Series to be mounted to any electrical enclosure easing installation UL508 Listed Designed and listed for field installation...makes electrical inspection a snap Switch position monitors Allows the control system to notify personnel when a load is inadvertently left ON or OFF (V122/V222 & V123/V223 models) Sleek enclosure Reduces the need for panel space The Victory 121, 122, and 123 Series HOA relays have a concealed HOA switch for local control and troubleshooting with limited unauthorized switch manipulation. To further guard against control system override, the V122/V222 and V123/V223 are equipped with a monitored HOA. The V122/V222 provides a two-wire resistive output and the V123/V223 offers a three-wire digital monitor. Now you can enjoy the convenience of local control with none of the drawbacks. SPECIFICATIONS Operating Temp. Range -40 to 60 °C (-40 to 131 °F) Operating Humidity Range 10 to 90% RH non-condensing Expected Relay Life Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles Relay Status LED ON=energized Insulation Class 277 Vac RMS WIRE SPECIFICATIONS Lead Length 14" (356 mm) min. Gauge UL1015; Coil: 18 AWG; Contacts: 12 AWG; HOA monitor wires: 16 AWG V122/V222 RESISTIVE MONITOR MAXIMUMS Voltage Max. 13.4 Vac/dc Current Max. 4 mA AC/DC V123/V223 DIGITAL MONITOR MAXIMUMS Dry Circuit Contact Rating (Max.) 24 Vac/dc@100 mA WARRANTY Limited Warranty 5 years APPLICATIONS · Command contactors · Control motors · Isolation · Device interlocking · Relay logic · Sense voltages for alarm conditions TYPICAL COIL PERFORMANCE Voltage Coil Current AC DC 24 V 75 mA 32 mA 120 V 42 mA 208 V 36 mA 277 V 39 mA CONTACT RATINGS V121, V221 Resistive 20 A @ 240 Vac 8 A @ 28 Vdc 12 A @ 14 Vdc Motor 1 HP ! 120 Vac V122, V123, V222, V223 Resistive 20 A @ 240 Vac 8 a @ 28 Vdc 14 A @ 14 Vdc Motor 1 HP @ 250 Vac AGENCY APPROVALS Agency Approvals UL 508 E150462 293 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NIPPLE MOUNT DIRECTLY TO A PANEL Wiring Diagram Relays | Victory 121, 122, & 123 Series DIMENSIONAL DRAWING 4.0" (103 mm) RESISTIVE INPUT DO 3.8" (97 mm) 2.0" (52 mm) NIPPLE MOUNT TO ANY 2X OR 4X ELECTRICAL BOX Wiring Diagram To Load CONTACTS COIL Wire Nut To Controls 2.3" (59 mm) 2.5" (64 mm) 3/4" NPT Nipple V123/V223 DIGITAL HOA POSITION MONITOR HAND BROWN OFF BROWN AUTO BROWN VIOLET VIOLET VIOLET WIRE COLOR CODES CONTROL SYSTEM INPUT HI wht/brown brown White brown 208 to 277 Vac or HI wht/black black White black 120 Vac LOW wht/blue COMM wht/yellow blue White blue 24 Vac/dc yellow White yellow Common HOA CONTACT OUTPUT N.O. Switch ORANGE Hand Off ORANGE Auto GREY GREY GREY Switch Positions: HAND = Brown wire closed to Common OFF = Both wires open to Common AUTO = Grey wire closed to Common VIOLET = Common V122/V222 RESISTIVE HOA POSITION MONITOR Switch Positions: Cable Faults: GREY HAND ~ 1.4 k OPEN = Infinite OFF ~ 6.2 k SHORT ~ 0 AUTO ~ 3.4 k GREY ORDERING INFORMATION MODEL RELAY COIL AMPERAGE RATING HOA HOA MONITOR RELAY POWER LED UL V121 24 Vac/dc, 120 Vac V122 24 Vac/dc, 120 Vac V123 24 Vac/dc, 120 Vac SPST, N.O. 20 A V221 24 Vac/dc, 208 to 277 Vac V222 24 Vac/dc, 208 to 277 Vac V223 24 Vac/dc, 208 to 277 Vac · None · Resistive · Digital · None · Resistive · Digital · · · · · · · · · · · · Note: Some units are Plenum rated per UL 1995. For details, see White Paper VWP01, UL 1995 and Plenum Ratings, at www.veris.com. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 294 Relays | Enclosed Victory Relays: 20 A DPDT VICTORY 320 & 420 DPDT Relays Provide Versatility V320 Sleek enclosure Reduces the need for panel space Flexible wire Flexible tinned stranded wire... fits easily in tight spaces and provides secure connections to wire nuts Nipple mount Can be mounted to any electrical enclosure, easing installation UL508 Listed Designed and listed for field installation...makes electrical inspection a snap APPLICATIONS V420 · Command contactors · Device interlocking · Control motors · Relay logic · Isolation · Sense voltages for alarm conditions The Victory 320 and 420 DPDT power duty enclosed relays combine industrial strength and ease of use. With the nipple mount enclosure, installation could not be easier. The V320/V420 need no dedicated field enclosure, so they are the ideal retrofit devices. One coil input controls the state of two power rated contacts for the simultaneous control of two devices or both poles of a single-phase circuit, e.g. motor loads. Fieldselectable high and low voltage coil inputs provide on-site versatility. SPECIFICATIONS Operating Temp Range Operating Humidity Range Expected Relay Life Relay Status Insulation Class WIRE SPECIFICATIONS Lead Length Gauge WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals -40° to 40°C (-40° to 104°F) 10 to 90% RH non-condensing Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles LED ON=energized 277 Vac RMS 14" (356 mm) min. UL1015; Coil: 18 AWG; Contacts: 12 AWG; HOA monitor wires: 16 AWG 5 years UL 508 TYPICAL COIL PERFORMANCE Voltage Coil Current AC DC 24 V 150 mA 64 mA 120 V 84 mA 277 V 102 mA CONTACT RATINGS Resistive 20 A @ 277 Vac, 28 Vdc Motor 120 Vac, 1 HP 277 Vac, 2 HP Pilot Duty A300 Ballast 20 A @ 277 Vac N.O. 10 A @ 277 Vac N.C. Tungsten 10 A @ 120 Vac N.O. 2 A @ 120 Vac N.C. E150462 295 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NIPPLE MOUNT DIRECTLY TO A PANEL Wiring Diagram To Load CONTACTS COIL To Controls CONTROL PANEL NIPPLE MOUNT TO ANY 2X OR 4X ELECTRICAL BOX Wiring Diagram Contacts To Load To Load CONTACTS COIL Wire Nut To Controls Relays | Victory 320 & 420 DIMENSIONAL DRAWING 4.0" (103 mm) 3.8" (97 mm) 2.0" (52 mm) 2.3" (59 mm) 2.5" (64 mm) 3/4" NPT Nipple WIRE COLOR CODES CONTROL SYSTEM INPUT brown HI brown wht/brown White 208 to 277 Vac or black HI wht/black black White 120 Vac blue LOW wht/blue COMM wht/yellow yellow blue White 24 Vac/dc White Common yellow CONTACT OUTPUT BLUE N.C. #1 YELLOW Common #1 ORANGE GREY VIOLET N.O. #1 N.C. #2 Common #2 BROWN N.O. #2 ORDERING INFORMATION MODEL RELAY COIL AMPERAGE RATING RELAY POWER LED UL V320 24 Vac/dc,120 Vac DPDT 20 A V420 24 Vac/dc, 208 to 277 Vac · · · · Note: Some units are Plenum rated per UL 1995. For details, see White Paper VWP01, UL 1995 and Plenum Ratings, at www.veris.com. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 296 Relays | Enclosed Victory Relays: 20 A DPST with HOA Switch VICTORY 321 & 421 HOA Switch Provides Local Control V321 Cover conceals HOA switch V421 Nipple mount Can be mounted to any electrical enclosure, easing installation Flexible wire Flexible tinned stranded wire... fits easily in tight spaces and provides secure connections to wire nuts Versatile ratings Versatile coil and contact ratings minimize the number of models to choose UL508 Listed Designed and listed for field installation...makes electrical inspection a snap Protective cover Conceals and protects the HOA switch, reducing the likelihood of tampering Sleek enclosure Reduces the need for panel space The Victory 321 and 421 DPST power duty enclosed relays combine an industrial strength relay with installation flexibility. Use the nipple mount to attach to any enclosure. One coil input controls the state of two power rated contacts for simultaneous control of two devices or both poles of a single phase load. Each output is enabled with a HandOff-Auto switch for local control. The Victory series does not require a dedicated field enclosure, so it is ideal for retrofit projects. Fieldselectable high and low voltage coil inputs provide on-site versatility. SPECIFICATIONS Operating Temp. Range Operating Humidity Range Expected Relay Life Relay Status Insulation Class WIRE SPECIFICATIONS Lead Length Gauge WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals -40 to 40 °C (-40 to 104 °F) 10 to 90% RH non-condensing Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles LED ON=energized 277 Vac RMS 14" (356 mm) min. UL1015; Coil: 18 AWG; Contacts: 12 AWG; HOA monitor wires: 16 AWG 5 years UL 508 APPLICATIONS · Command contactors · Control motors · Isolation · Device interlocking · Relay logic · Sense voltages for alarm conditions TYPICAL COIL PERFORMANCE Voltage Coil Current AC DC 24 V 120 mA 64 mA 120 V 84 mA 277 V 102 mA CONTACT RATINGS Resistive 20 A @ 240 Vac 8 A @ 28 Vac 14 A @ 14 Vac Motor 120 Vac, 1 HP E150462 297 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com NIPPLE MOUNT DIRECTLY TO A PANEL Wiring Diagram To Load CONTACTS COIL To Controls CONTROL PANEL NIPPLE MOUNT TO ANY 2X OR 4X ELECTRICAL BOX Wiring Diagram Contacts To Load CONTACTS To Load COIL Wire Nut To Controls Relays | Victory 321 & 421 DIMENSIONAL DRAWING 4.0" (103 mm) 3.8" (97 mm) 2.0" (52 mm) 2.3" (59 mm) 2.5" (64 mm) 3/4" NPT Nipple WIRE COLOR CODES CONTROL SYSTEM INPUT brown HI (421) brown wht/brown White 208 to 277 Vac or black HI (321) wht/black black White 120 Vac LOW wht/blue COMM wht/yellow yellow White 24 Vac/dc White Common yellow CONTACT OUTPUT #1 N.O. HOA Switch ORANGE Hand Off ORANGE Auto CONTACT OUTPUT #2 N.O. HOA Switch BROWN Hand Off BROWN Auto ORDERING INFORMATION MODEL RELAY COIL AMPERAGE RATING HOA RELAY POWER LED UL V321 24 Vac/dc,120 Vac · DPST 20 A V421 24 Vac/dc, 208 to 277 Vac · · · · · Note: Some units are Plenum rated per UL 1995. For details, see White Paper VWP01, UL 1995 and Plenum Ratings, at www.veris.com. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 298 Relays | Mini Command Victory Relay: 10 A SPDT VICTORY 645 Economical 10 A Relay in a Small Package for Tight Spaces Economical multi-voltage relay Switching Switch up to 10 A@250 Vac Flexible Mounting 24 to 30 Vac/dc or 120 Vac coil options V645 input provides application Ships with foam tape, mounting flexibility screw, and DIN rail clip Easy diagnostics Status LED for visual indication The Victory 645 is an economical, multi-purpose relay designed for control of loads up to 10 A. Its small size allows for space saving utility in panels and field enclosures. APPLICATIONS · Sense voltages for alarm conditions · Relay logic · Isolation · For start/stop of small motors & contactors · Device interlocking SPECIFICATIONS Operating Temp. Range Operating Humidity Range Expected Relay Life Relay Status Dielectric Strength WIRE SPECIFICATIONS Lead Length Gauge WARRANTY Limited Warranty AGENCY APPROVALS Agency Approvals 0 to 60 °C (32 to 140 °F) 10% to 90% RH non-condensing Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles LED ON = Energized 1500 Vac RMS 10" (254 mm) min. UL1015; Coil: 18 AWG; Contacts: 16 AWG 5 years UL 508 TYPICAL COIL PERFORMANCE Voltage Coil Current AC DC 24 to 30 V 32 mA 13 mA 120 V 17 mA CONTACT RATINGS Resistive 10 A @ 250 Vac, N.O. 7 A @ 250 Vac, N.C. 6 A @ 277 Vac 7 A @ 30 Vdc Motor 125 Vac, 1/4 HP, H.P. E150462 299 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com WIRING DIAGRAMS PANEL To Load To Load V645 24V Coil 120V PANEL V645 24V Coil 120V DIGITAL CONTROL POWER SOURCE Relays | Victory 645 DIMENSIONAL DRAWING 1.1" (28 mm) 0.6 (14 mm) 1.3" (33 mm) (130m.5m)(301m.2m) Ø 0.15" (4 mm) MOUNTING METHOD 1.1 (28 mm) * Wire is capped on unused option. WIRE COLOR CODES CONTROL SYSTEM INPUT Black Black HI White 120 Vac Blue LOW Blue White 24 Vac/dc COMM Yellow White Common Yellow CONTACT OUTPUT BLUE N.C. YELLOW Common ORANGE N.O. The V645 comes with a DIN rail clip, screw, and foam tape for a variety of mounting methods. ORDERING INFORMATION MODEL V645 RELAY COIL SPDT 24 to 30 Vac/dc, 120 Vac AMPERAGE RATING 10 A RELAY POWER LED UL · · 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 300 Relays | Socket SPDT Relays VMD1B-C & VMD1B-F SERIES Socket Relays in a Wide Range of Coil Voltages VMD1B-F VBD1B-F VMD1B-C Color-coded pushbutton Allows manual operation of relay, AC coils red or DC coils blue (-F Series only) Override lever When activated, locks pushbutton and contacts in the powered position (-F Series only) LED status lamp Shows coil "ON" or "OFF" status (-F Series only) Flag indicator Shows relay status in manual or powered condition (-F Series only) 2-way mounting Side or DIN rail mounting system...retrofits existing panel mounting and 35 mm DIN rail VBD1B-C The Veris VMD1B-C Series are SPDT blade-style relays for socket/DIN mounting. The DIN-rail compatible VBD1B-C sockets feature finger-safe terminals in a slim, attractive design. The Veris VMD1B-F Series are full-featured SPDT blade style relays for socket/DIN mounting. The VMD1B-F Series are equipped with an LED for coil proof, a flag for contact proof, an override lever, and a push-to-test button for momentary contact control. The VMD1B-F allows for instant and conclusive troubleshooting. Never wonder if the relay, control system, or wiring is the cause of a problem. The DIN-rail-compatible VBD1B-F sockets feature a slim design with finger-safe terminals and a removable hold-down clip. Never struggle with wire clips again. TYPICAL COIL PERFORMANCE Power Consumption AC Coils 0.9 VA DC Coils 0.7 VA CONTACT RATINGS Standard (F & C Series) Resistive 15 A @ 120 Vac 15 A @ 277 Vac 15 A @ 28 Vdc Motor 1/3 @ 120 Vac 3/4 @ 277 Vac Pilot Duty B300 SPECIFICATIONS Operating Temp. Range Coil Operating Range Coil Drop-out Voltage Threshold Expected Relay Life Operating Time Dielectric Strength WARRANTY Limited Warranty AGENCY APPROVALS -40 to 55 °C (-40 to 131 °F) 85% to 110% of rated voltage 15% of rated voltage Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles 20 msec typical 1500 Vac RMS 5 years E198453 301 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com VBD1B SOCKET Wiring Diagram Function Coil (+)* Coil (-)* COMM N.O. N.C. NEMA (IEC) Terminal 14 (A2) 13 (A1) 9 (11) 5 (14) 1 (12) TOP VIEW 5(14) 1(12) * NOTE: Observe polarity for relays with DC coil voltages only. 14(A2) 13(A1) 9(11) Relays | VMD1B-C & VMD1B-F Series VMD1B SOCKET Dimensional Drawing 0.8" (20 mm) 1.1" (28 mm) 2.7" (69 mm) 0.7" (18 mm) VMD1B RELAYS Dimensional Drawing 0.2" (5 mm) Hold Down Clip included with F Model socket 1.1" (28 mm) 1.4" (36 mm) 0.6" (15 mm) ORDERING INFORMATION MODEL VMD1B-C12D VMD1B-C24D VMD1B-C24A VMD1B-C120A VMD1B-F12D VMD1B-F24D VMD1B-F24A VMD1B-F120A RELAY TYPE SPDT AMPERAGE RATING 15 A 15 A 15 A 15 A 15 A 15 A 15 A 15 A COIL VOLTAGE 12 Vdc 24 Vdc 24 Vac 120 Vac 12 Vdc 24 Vdc 24 Vac 120 Vac MIN. SWITCHING CURRENT 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc FULL FEATURED · · · · UL CE ·· ·· ·· ·· ·· ·· ·· ·· SOCKET ORDERING INFORMATION MODEL AMPERAGE RATING VOLTAGE RATING FINGER SAFE VBD1B-C 15 A VBD1B-F · 300 V · When relays and sockets are used together, amperage rating is the lesser of the two ratings. HOLD DOWN CLIP · UL CE ·· ·· 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 302 Relays | DPDT Relays VMD2B-C & VMD2B-F SERIES Socket Relays in a Wide Range of Coil Voltages VMD2B-C Color-coded push button Allows manual operation of relay, AC coils red or DC coils blue (-F Series only) Override lever When activated, locks pushbutton and contacts in the powered position (-F Series only) VBD2B-C LED status lamp Shows coil "ON" or "OFF" status (-F Series only) Flag indicator Shows relay status in manual or powered condition (F Series only) VMD2B-F VBD2B-F 2-way mounting Side or DIN rail mounting system...retrofits existing panel mounting and 35 mm DIN rail Veris VMD2B Series are DPDT blade-style relays for socket/DIN mounting. The VMD2B-F is the full-featured model in a slim housing. The LED, the flag indicator, and the test button allow for worry-free operation and easy troubleshooting with minimal downtime. Never wonder where the problem is! SPECIFICATIONS Operating Temp. Range Coil Operating Range Coil Drop-out Voltage Threshold Expected Relay Life Operating Time Dielectric Strength WARRANTY Limited Warranty AGENCY APPROVALS -40 to 55 °C (-40 to 131 °F) 85% to 110% of rated voltage 15% of rated voltage Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles 20 msec typical 1500 Vac (RMS) 5 years E198453 E150462 TYPICAL COIL PERFORMANCE Power Consumption AC Coils 1.2 VA DC Coils 0.9 W CONTACT RATINGS Standard (F & C Series) Resistive 15 A @ 120 Vac 12 A @ 277 Vac 12 A @ 28 Vdc Motor 1/2 HP @ 120 Vac 1 HP @ 250 Vac Pilot Duty B300 303 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com VBD2B SOCKET Wiring Diagram Function Terminal Coil (+)** 8 Coil (-)** 7 COMM1 5 N.O.1 3 N.C.1 1 COMM2 6 NO.2 4 N.C.2 2 NEMA (IEC) 14 (A2) 13 (A1) 9 (11) 5 (14) 1 (12) 12 (41) 8 (44) 4 (42) VMD2B RELAY Wiring Diagram TOP VIEW 8(44) 5(14) 4 3 4(42) 1(12) 2 1 14 (A2) 13 (A1) 87 12(41) 9(11) 6 5 Relays | VMD2B-C & VMD2B-F Series VBD2B-F SOCKET Dimensional Drawing 3.1" (79mm) 1.2" (30mm) 1.1" (28mm) VBD2B-F SOCKET Dimensional Drawing 1.4" (35 mm) 0.9" (23 mm) 1.1" (28 mm) 3.1" (79mm) 1.2" (30mm) 1.1" (28mm) ORDERING INFORMATION MODEL VMD2B-C12D VMD2B-C24D VMD2B-C24A VMD2B-C120A VMD2B-F12D VMD2B-F24D VMD2B-F24A VMD2B-F120A VMD2B-F240A RELAY TYPE DPDT AMPERAGE RANGE 15 A 15 A 15 A 15 A 15 A 15 A 15 A 15 A 15 A COIL VOLTAGE 12 Vdc 24 Vdc 24 Vac 120 Vac 12 Vdc 24 Vdc 24 Vac 120 Vac 240 Vac MIN. SWITCHING CURRENT 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc 100 mA@5 Vdc FULL FEATURED · · · · · UL CE ·· ·· ·· ·· ·· ·· ·· ·· ·· SOCKET ORDERING INFORMATION MODEL AMPERAGE RATING VOLTAGE RATING FINGER SAFE VBD2B-F 20 A 300 V · When relays and sockets are used together, amperage rating is the lesser of the two ratings. HOLD DOWN CLIP · UL CE ·· 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 324 304 Relays | Socket 3PDT Relays VMD3B & VMD3B-C SERIES Socket Relays with a Wide Range of Features and Coil Voltages VMD3B-C VBD3B-C VMD3B-F VBD3B-F Color-coded push buttons Allows manual operation of relay. AC coils red, DC coils blue. (-F Series only) 2-way mounting Side or DIN rail mounting system...retrofits existing panel mounting and 35 mm DIN rail Override lever I.D. tag When activated, locks push button I.D. tag/write-on plastic label... and contacts in the powered used for identification of relays in position (-F Series only) multi-relay circuits (-F Series only) Flag indicator Shows relay status in manual or powered condition (-F Series only) LED status lamp Shows coil "ON" or "OFF" status (-F Series only) The VMD3B Series are 3PDT blade-style relays for socket/DIN mounting. The standard VMD3B-C model is economical and reliable. The fullfeatured VMD3B-F includes an LED and a flag indicator for convenient status viewing and a push-button test feature for easy troubleshooting. The finger-safe sockets reduce risk, and the hold-down clip keeps the device secure. Enhanced safety and dependability. SPECIFICATIONS Operating Temp. Range Coil Operating Range Coil Drop-out Voltage Threshold Expected Relay Life Operating Time Dielectric Strength WARRANTY Limited Warranty AGENCY APPROVALS -40 to 55 °C (-40 to 131 °F) 85% to 110% of rated voltage 15% of rated voltage Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles 20 msec typical 1500 Vac RMS 5 years E198453 E150462 TYPICAL COIL PERFORMANCE Power Consumption AC Coils 1.2 VA DC Coils 1.4 W CONTACT RATINGS Resistive 15 A @ 120 Vac 12 A @ 277 Vac 12 A @ 28 Vdc Motor 1/2 HP @ 120 Vac 3/4 HP @ 250 Vac Pilot Duty B300 305 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Relays | VMD3B & VMD3B-C Series VBD3B SOCKET Wiring Diagram Function Coil (+)* Coil (-)* COMM1 N.O.1 N.C.1 COMM2 N.O.2 N.C.2 COMM3 N.O.3 N.C.3 Terminal NEMA/(IEC) 11 14 (A2) 10 13 (A1) 7 9 (11) 4 5 (14) 1 1 (12) 8 10 (21) 5 6 (24) 2 2 (22) 9 12 (41) 6 8 (44) 3 4 (42) TOP VIEW 8(44) 6(24) 5(14) 65 4 4(42) 2(22) 1(12) 32 1 14 (A2) 13 (A1) 11 10 12(41) 10 (21) 9(11) 98 7 *Observe polarity for relays with DC coil voltages only VBD3B-C SOCKET Wiring Diagram 1.4" (36mm) 1.1" (28mm) VBD3B-F SOCKET Wiring Diagram 3.1" (79mm) Hold Down Clip included with F Model 1.5" (38mm) 1.1" (28mm) VMD3B RELAY Wiring Diagram 1.3" (33 mm) 2.6" (66mm) 1.6" (41mm) ORDERING INFORMATION MODEL RELAY TYPE VMD3B-C24D VMD3B-C24A VMD3B-C120A VMD3B-F24D VMD3B-F24A VMD3B-F120A 3PDT AMPERAGE RANGE 10 A 15 A COIL VOLTAGE 24 Vdc 24 Vac 120 Vdc 24 Vdc 24 Vac 120 Vac 1.1" (27 mm) 1.4" (36 mm) MIN. SWITCHING CURRENT 100 mA@5 Vdc FULL FEATURED · · · UL CE ·· ·· ·· ·· ·· ·· SOCKET ORDERING INFORMATION MODEL VBD3B-F AMPERAGE RATING 16 A VOLTAGE RATING 300 V FINGER SAFE · When relays and sockets are used together, amperage rating is the lesser of the two ratings. HOLD DOWN CLIP · UL CE ·· 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 324 306 Relays | Socket 4PDT Relays VMD4B & VMD4B-C SERIES Socket Relays with a Wide Range of Features and Coil Voltages VMD4B-C VBD4B-C VMD4B-F Color-coded pushbuttons Allows manual operation of relay. AC coils red, DC coils blue. (-F Series only) 2-way mounting Side or DIN rail mounting system...retrofits existing panel mounting and 35 mm DIN rail Override lever ID tag When activated, locks pushbutton and contacts in the powered position (-F Series only) ID tag/write-on plastic label... used for identification of relays in multi-relay circuits (-F Series only) Flag indicator Shows relay status in manual or powered condition (-F Series only) LED status lamp Shows coil "ON" or "OFF" status (-F Series only) VBD4B-F The Veris VMD4B Series are 4PDT blade-style relays for socket/DIN mounting. Both the full-featured and standard DIN rail sockets are compatible with both the VMD4B-C and VMD4B-F relays and feature a slim, attractive design. The standard VMD4B-C model is economical and reliable. The fullfeatured VMD4B-F includes an LED and a flag indicator for convenient status viewing and a push-button test feature for easy troubleshooting. The finger-safe sockets reduce risk, and the hold-down clip keeps the device secure. Enhanced safety and dependability. SPECIFICATIONS Operating Temp. Range Coil Operating Range Coil Drop-out Voltage Threshold Expected Relay Life Operating Time Dielectric Strength WARRANTY Limited Warranty AGENCY APPROVALS -40 to 55 °C (-40 to 131 °F) 85% to 110% of rated voltage 15% of rated voltage Electrical (@ rated current) 100,000 cycles; Mechanical (unpowered) 10,000,000 cycles 20 msec typical 1500 Vac RMS 5 years E198453 E150462 TYPICAL COIL PERFORMANCE Power Consumption AC Coils 1.5 VA DC Coils 1.5 W CONTACT RATINGS Resistive 10 A @ 120 Vac 10 A @ 277 Vac 10 A @ 28 Vdc Motor 1/3 HP @ 120 Vac 1/2 HP @ 250 Vac Pilot Duty B300 307 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Relays | VMD4B & VMD4B-C Series VBD4B SOCKET Wiring Diagram Function Coil (+)* Coil (-)* COMM1 N.O.1 N.C.1 COMM2 N.O.2 N.C.2 COMM3 N.O.3 N.C.3 COMM4 N.O.4 N.C.4 NEMA (IEC) Terminal 14 (A2) 13 (A1) 9 (11) 5 (14) 1 (12) 10 (21) 6 (24) 2 (22) 11 (31) 7 (34) 3 (32) 12 (41) 8 (44) 4 (42) TOP VIEW 8(44) 7(34) 6(24) 5(14) 4(42) 3(32) 2(22) 1(12) 14 (A2) 13 (A1) 12(41) 11(31) 10(21) 9(11) *Observe polarity for relays with DC coil voltages only VMD4B RELAY Dimensional Drawing 1.7" (43 mm) VBD4B-F SOCKET Dimensional Drawing 3.1" (80 mm) Hold Down Clip included with F Model socket 2.0" (51 mm) 1.1" (28 mm) VBD4B-F SOCKET Dimensional Drawing 2.0" (51 mm) 1.1" (28 mm) 1.1" (27 mm) 1.4" (36 mm) ORDERING INFORMATION MODEL VMD4B-C24D VMD4B-C24A VMD4B-C120A VMD4B-F24D VMD4B-F24A VMD4B-F120A RELAY TYPE 4PDT AMPERAGE RANGE 10 A COIL VOLTAGE 24 Vac 24 Vac 120 Vac 24 Vdc 24 Vac 120 Vac 2.6" (66mm) 1.8" (46 mm) MIN. SWITCHING CURRENT 100 mA@5 Vdc FULL FEATURED · · · UL CE ·· ·· ·· ·· ·· ·· SOCKET ORDERING INFORMATION MODEL AMPERAGE RATING VOLTAGE RATING FINGER SAFE VBD4B-C 10 A VBD4B-F 10 A 300 V · When relays and sockets are used together, amperage rating is the lesser of the two ratings. HOLD DOWN CLIP · UL CE ·· ·· 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com ACCESSORIES P. 324 308 Relays | Solid State Relays VS861 SERIES No moving parts EMI Higher Reliability than Electromagnetic Relays No moving parts to wear or fail Reduced EMI Contacts No contact bounce or arcing contacts Long life Longer life than electromechanical relays VS861210DC The DIN-mountable VS861 Series Solid State Relay with an internal heat sink is the first complete solid state relay available in a modular package. A SSR (solid state relay) can perform many of the same tasks as an electromechanical relay. The SSR differs in that it contains no moving mechanical parts. It is essentially an electronic device that relies on the electrical, magnetic, and optical properties of semiconductors and electrical components to achieve its isolation and relay switching function. Superior performance Fast response time and high frequency of on/off cycling APPLICATIONS · Lighting · Instrumentation systems and alarm systems · Traffic control · Industrial automation SPECIFICATIONS OUTPUT CHARACTERISTICS Switching Voltage VS861210DC(AC) & VS861208DC(AC): 24 to 280 Vac, VS861208DD: 3 to 150 Vdc Maximum Zero Turn-on Voltage (Vpk) VS861210DC(AC) & VS861208DC(AC): 35 V Maximum Rate of Rise Off State Voltage (dv/dt) VS861210DC(AC): 500 V/S, VS861208DC: 475 V/S, VS861208AC: 350 V/S Incandescent Lamp Ampere VS861210DC(AC): 8 A, Rating (RMS) VS861208DC(AC): 5 A Motor Load Rating (RMS) VS861210DC(AC): 4.5 A, VS861208DC(AC): 3 A Min. Load Current to Maintain On VS861210DC(AC): 50 mA, VS861208DC(AC): 150 mA, VS861208DD: 20 mA Non-Repetitive Surge Current (1 cycle) VS861210DC(AC): 500 A, VS861208DC(AC): 200 A, VS861208DD: 35 A Max. RMS Overload Current VS861210DC(AC) & VS861208DC: 24 A, (1 sec.) VS861208(DD): 17 A Max. Off State Leakage Current (RMS) 10 mA Typical On State Voltage Drop (RMS) 1.25 Vac Max. On State Voltage Drop VS861210DC(AC) & VS861208DC(AC): 1.6 Vac, (RMS) VS861208DD: 1.6 Vdc INPUT CHARACTERISTICS Must Release Voltage VS861210DC, VS861208DC, & VS861208DD: 1 Vdc, VS861210AC & VS861208AC: 10 Vac SP (Nominal) Input Impedance VS861210DC, VS861208DC, & VS861208DD: Current Regulator; VS861210AC & VS861208AC: 16 to 25 k Typical Input Current @ 5 Vdc or 240 Vac VS861210DC: 16 mA, VS861210AC, VS861208DC(AC), & VS861208DD: 12 mA Reverse Polarity Protection VS861210DC, VS861208DC, & VS861208DD: Yes OTHER CHARACTERISTICS Operating Time (Response Time) VS861210DC & VS861208DC: 8.3 msec; VS861210AC & VS861208AC: 40 msec; VS861208DD: 5 msec Release Time VS861210DC & VS861208DC: 8.3 msec; VS861210AC & VS861208AC: 80 msec; VS861208DD: 5msec Rated Insulation Voltage/ Dielectric Strength 2500 Vac Operating Temp Range -30 to 80 °C (-22° to 176 °F) Thermal Resistance (Junction to Case) VS861210DC(AC): 0.66 °C/W, VS861208DC(AC): 2.0 °C/W, VS861208DD: 0.5 °C/W Integral Heat Sink 4.0 °C/W WARRANTY Limited Warranty 5 years AGENCY APPROVALS E150462 309 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Relays | VS861 Series WIRING DIAGRAM CONTROLLER + LOAD DIMENSIONAL DRAWINGS Ø .19" (5 mm) INPUT SSR OUTPUT + AC INPUT 4.2" (107 mm) 3.5" (90 mm) 1.4" (36 mm) WIRING DIAGRAM AMPERAGE DERATING FOR TEMPERATURE Load Current (Amps RMS) Load Current (Amps RMS) 8 AMP STYLE 25° 9 8 7 6 5 4 85° 3 1.5* 2 1 0 0 20 40 60 80 100 *Cut off current Max. Am bient Tem p (°C) LOAD CONSIDERATIONS The primary concern when using SSRs is improper heat sinking. The type of load current should be evaluated when considering an SSR as a switching option. SSRs alone are not compatible with high inrush currents, but cautionary measures can be taken in high inrush applications to increase the SSR's versatility, see table at right. 0.7" (18 mm) 2.6" MAX (65 mm) 10 AMP STYLE 12 25° 10 8 6 4 80° 2 1.8* 0 0 20 40 60 80 100 *Cut off current Max. Am bient Tem p (°C) LOAD TYPE All Load Types Steady-state Resistance DC (Inductive) Incandescent Lamp Capacitive Motors and Solenoids Transformers CAUTIONARY ACTION Verify that the inrush current does not exceed the surge specifications of the SSR. Consider thermal management. Assure device temperature will remain in safe operating area. Place a diode across the load to absorb surges during turnoff. Use a zero voltage turn-on type. Verify that the rate of current rise capabilities are not exceeded. Zero voltage turn-on is an effective method for limiting this rate. Use a current shunt and oscilloscope to examine the duration of the inrush current. Verify that back EMF does not create an overvoltage situation during turn-off. Use a zero cross turn-on device; verify that the half cycle surge capability is not exceeded. Rule of thumb: select an SSR with a half cycle current surge rating greater than the maximum applied line voltage divided by the transformer primary resistance. ORDERING INFORMATION MODEL VS861210DC VS861210AC VS861208DC VS861208AC VS861208DD RELAY SPST, N.O. AMPERAGE RATING 10 A 10 A 8 A 8 A 8 A INPUT VOLTAGE 3 to 32 Vdc 90 to 280 Vac, 80 to 140 Vdc 3 to 32 Vdc 90 to 280 Vac, 80 to 140 Vdc 3.5 to 32 Vdc SWITCHING DEVICE SWITCHING VOLTAGE SCR 24 to 280 Vac SCR 24 to 280 Vac Triac 24 to 280 Vac Triac 24 to 280 Vac MOSFET 3 to 150 Vdc SWITCHING TYPE Zero Cross Zero Cross Zero Cross Zero Cross DC Switching UL CE ·· ·· ·· ·· ·· 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 310 Relays | Time Delay Relays VTD SERIES VTD2P-UNI VTD2P-F50 VBD3P-C Thumb wheel adjustment VTD2P-F50 has thumb wheel adjustment for function and timing accuracy Solid state relays VTD1P/2P-UNI models are made with solid state relays for greater reliability Housing options Two different housings provide multiple mounting options The Veris VTD Series are multi-function time delay relays equipped with an external control switch input and designed for easy socket/DIN mounting. The VTD2P-F50 includes five functions shown at left, while the VTD1P-UNI and VTD2P-UNI include the same five as the VTD2P-F50 plus five more, for the most versatile relay available. Save inventory costs by purchasing one relay for all the functions you need. SPECIFICATIONS Operating Range 85% to 110% of nominal voltage Drop-Out Voltage Threshold 15% of nominal voltage FUNCTION TIMING CHART Expected Relay Life Dielectric Strength Operating Temp Range WARRANTY Limited Warranty AGENCY APPROVALS Electrical (resistive @ rated curreU nt) 1T 00,000 cycles; Mechanical (unpowerOeNdD)E1L0AY,000R ,000 cycles time 1000 Vac RMS REPEAT CYCLE: U -20 to 55 °C (-4 to 1S3ta1rt°inFg)Open R TTTT OFF ON OFF ON time 5 years U T INTERVAL R time * E198453 E310313 *The CE mark indicates RoHS2 compliance. REPEAT CYCLE: U T T T T Starting Closed R ON OFF ON OFF time PULSE U T GENERATOR R Pulse time POWER TRIGGER FUNCTION TIMING CHART U T ON DELAY R time REPEAT CYCLE: U T T T T Starting Open R OFF ON OFF ON time U T INTERVAL R time REPEAT CYCLE: U T T T T Starting Closed R ON OFF ON OFF time PULSE U T GENERATOR R Pulse time SWITCH TRIGGER FUNCTION TIMING CHART U OFF DELAY S R T time UT RETRIGGERABLE S ONE SHOT R T time UT ONE SHOT S R T time U ON & OFF DELAY S R U MEMORY LATCH S R TT time time TYPICAL COIL PERFORMANCE Power Consumption AC Coils 1.5 VA DC Coils 2 w CONTACT RATINGS (VTDP-F50) Resistive 12 A @ 240 Vac, 30 Vdc Pilot Duty B300 (VTD1p-UNI, VTD2P-UNI) Resistive 15A @ 240 Vac, 24 Vdc Motor 1/2 HP @ 120 Vac; 1 HP @ 240 Vac TIMING CHARACTERISTICS VTD2P-F50 VTD1P-UNI, VTD2P-UNI Function Available 5 10 Time Ranges 0.1 sec sec 0 to 999 0 to 999 1 to 10 1 to 10 0.1 min min 0 to 999 0 to 999 1 to 10 1 to 10 0.1 hr hr 0 to 999 0 to 999 1 to 10 1 to 10 10 hr 0 to 999 --- 0.1 day day --- 1 to 10 --- 1 to 10 Tolerance (mechanical setting) 0% 5% Repeatability 0.1% 0.2% Operate Time (max) 25ms no spec Rest Time (max) 150 ms 150 ms Trigger Pulse Length (min) --- 50 ms U: Input voltage (power supply) S: Control switch (open or closed) R: RFeUlaNyCcToIOnNtacts (on or ToIfMf)ING CHARTT: Setting time U OFF DELAY S 311 R T time 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com UT T VTD1P-UNI/VTD2P-UNI Dimensional Drawing VTD1P-UNI INPUT VOLTAGE Un +- A1 S A2 EXTERNAL CONTROL SWITCH R INPUT VOLTAGE Un +- A1 S A2 EXTERNAL CONTROL SWITCH INPUT VOLTAGE Un +- A1 S A2 R 25 26 28 R R VTD2P-UNI INPUT15 16 18 VOLTAGE 15 16 18 Un +- A1 S A2 R 25 26 28 R 15 - COMMON 16 - NORMALLY CLOSED 18 - NORMALLY OPEN 25 - COMMON 26 - NORMALLY CLOSED 28 - NORMALLY OPEN 15 16 18 15 16 18 VTD2P-F50 Wiring Diagram 15 - COMMON 16 - NORMALLY CLOSED 18 - NORMALLY OPEN 25 - COMMON 26 - NORMALLY CLOSED 28 - NORMALLY OPEN EXTERNAL CONTROL SWITCH 567 4 8 3 9 2 10 1 11 INPUT Relays | VTD Series VTD2P-F50 Dimensional Drawing RED LED OUTPUT INDICATOR Positive position thumb wheel adjustments A 0 0 0S 1.9" (48 mm) 1.9" (48 mm) 3.5" (89 mm) 1.8" (45 mm) PANEL CUTOUT FOR PANEL MOUNTING 1.8" (45 mm) VTD1P-UNI/VTD2P-UNI Dimensional Drawing 3.5" (90 mm) 1.4" (36 mm) 0.7" (18 mm) 2.6" MAX (65 mm) VBD3P-C Dimensional Drawing 2.3" (58 mm) 1.0" (25 mm) 2.1" (53 mm) RELAY ORDERING INFORMATION MODEL VTD2P-F50 VTD1P-UNI VTD2P-UNI RELAY STYLE DPDT SPDT DPDT NO. OF FUNCTIONS 5 10 10 *UL Listed when used with Veris sockets. AMPERAGE RANGE 12 15 15 COIL VOLTAGE 24 to 240 Vac/dc 24 to 240 Vac/dc 24 to 240 Vac/dc MIN. SWITCHING CURRENT 100 mA@5 Vdc UL CE Recognized* · Listed · Listed · SOCKET ORDERING INFORMATION MODEL AMPERAGE RATING VOLTAGE RATING VBD3P-C 15 A 300 UL CE ·· When relays and sockets are used together, the overall amperage rating is the lesser of the two ratings. 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 312 Relays | Accessories Selection Guide ACCESSORIES SELECTION GUIDE: RELAYS VST10 & 100 VST120 VMD1B-C & VMD1B-F VMD2B-C & VMD2B-F VMD3B-C & VMD3B-F VMD4B-C & VMD4B-F Product AV01 AV02 AV05 Description 35 mm DIN Rail - 1 Meter Length DIN Rail Stop Clip 2.75" SNAPTRACK, 2" Length ···· ···· ·· AV01 35 mm DIN Rail - 1 Meter Length AV02 DIN Rail Stop Clip AV05 (2.75") 2.75" SNAPTRACK, 2" Length 313 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Relays | Accessories 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 314 POWER SOURCES Veris provides a wide range of AC or DC output power supplies. Veris AC transformers are available with or without a circuit breaker and with single or dual threaded hubs. All come standard with foot mounting flanges and flying lead terminations. Capacities range from 20 to 375 VA. Veris offers a line of low heat generating, fully enclosed DC power supplies as well. These sleek DIN mount units are available in 12 or 24 Vdc outputs from 7.5 to 90 Watts in capacity. MODEL PS X DESCRIPTION Power Supplies Control Transformers PAGE 317 319 POWER SOURCES SELECTION GUIDE DC Power Supply Control Transformers * Indicates a series of products. PS* page 317 X* page 319 315 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com A CONVENIENT SOURCE OF AC CONTROL POWER FOR HVAC CONTROL AND BUILDING AUTOMATION APPLICATIONS X Series Control Transformers APPLICATIONS » Controller power » Driving relays and other digital I/O circuits » Powering sensors FEATURES FLEXIBILITY YOU WANT Multiple hub/foot mounting and voltage options availible CERTIFICATION YOU NEED UL Listings for all models RIGHT PRODUCT FOR THE JOB Current limiting options available 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 316 Power Sources | Power Supplies PS SERIES PS Series Switching Power Supplies PS Series Capable of supplying up to 90 Watts (AV01 DIN rail not included) SPECIFICATIONS Input Voltage (except PSxx-100W) Input Voltage (PSxx-100W) Input Current (Typical @100 Vac) 7.5 W (12 and 24 Vdc) 15 W (12 and 24 Vdc) 30 W (12 and 24 Vdc) 60 W 90 W Inrush Current (100 Vac) Overcurrent Protection Ripple Leakage Current Output Current (12 V Models) 7.5 W 15 W 30 W Output Current (24 V Models) 7.5 W 15 W 30 W 60 W 90 W Operating Temperature Operating Humidity Storage Temperature 100 to 240 Vac (85 to 264 Vac), 50/60Hz (47 to 63 Hz); 110 to 340 Vdc (105 to 370 Vdc) 100 to 120/200 to 240 Vac, Jumper Selectable 50/60 Hz (47 to 63 Hz); 240 to 370 Vdc 0.18 A 0.35 A 0.7 A 1.3 A 1.1 A 15 A (7.5 W) 18 A (15 W and up) 105% min. auto-reset 24 V, 4% P-P 12 V, 6% P-P 120 Vac, 0.5 mA max. 230 Vac, 1.0 mA max. 0.6 A 1.3 A 2.5 A 0.3 A 0.65 A 1.3 A 2.5 A 3.75 A -25 to 75 °C (-13 to 167 °F) 20 to 90% RH non-condensing -25 to 75 °C (-13 to 167 °F) Up to 90 W High efficiency switching power supply capable of supplying up to 90 W DIN rail mounting Easy installation Loop power Ideal for supplying loop power to Veris power transducers and current sensors Small size Saves panel space Universal voltage input Universal voltage input from 100 to 240 Vac/110 to 340 Vdc High efficiency Won't generate excessive heat in control panel DIMENSIONAL DRAWING H W D WEIGHT (APPROX.) H 7.5 W 3.0" 1.9" 2.8" (75 mm) (45 mm) (70 mm) 130 g 15 W 3.6" 0.9" 3.8" (90 mm) (22.5 mm) (95 mm) 140 g W 30 W 3.6" 0.9" 3.8" 150 g (90 mm) (22.5 mm) (97 mm) 60 W 3.8" 1.5" 4.3" (95 mm) (36 mm) (108 mm) D 90 W 3.8" 1.5" 4.3" (95 mm) (36 mm) (108 mm) 260 g 310 g Terminals AGENCY APPROVALS Spring-up, finger-safe (when tightened); captive M3.5 screws Phillips/flat heads 317 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com SUPPLYING POWER FOR ALL YOUR DC NEEDS PS Series Power Sources | PS Series PX3 Pressure Monitoring H321 Current Monitoring A8332 Network Integration ORDERING INFORMATION Output PS Watts S W 12 =12 Vdc 24 = 24 Vdc 7.5 = 7.5 Watts 15 = 15 Watts 30 = 30 Watts 60* = 60 Watts 90* = 90 Watts *Available in 24 V only. Example: PS 12 S 7.5 W CW2/HW2/TW2 CO2 /Humidity/Temp. Monitoring CDL CO2 Monitoring SDI0H1N20-0200 Flow Monitoring 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 318 Power Sources | Control Transformers X SERIES Plate Mount 2 Hub and Foot Mount Foot Mount UL Listings UL Listings for all models simplify panel building requirements Threaded hub options Threaded hub options maximize installation flexibility One-stop shopping Save time by ordering along with other Veris products 1 Hub and Foot Mount 1 Hub and Foot with Separate Secondary Wires Veris X Series Control Transformers are a convenient source of control power for HVAC control and building automation applications. A wide variety of UL-listed transformers are available with single and dual threaded hub mounting options. Multiple current limiting options are available, including a circuit breaker in some models. Save ordering time and purchase order costs when buying other Veris sensors by including transformers in your order. APPLICATIONS · Controller power · Driving relays and other digital I/O circuits DIMENSIONAL DRAWING W H · Powering sensors L A B SPECIFICATIONS Frequency Operating Temperature No Load Voltage Hub Style Wire Wire Length WARRANTY Limited Warranty AGENCY APPROVALS 50/60 Hz -40 to 65 °C (-40 to 149 °F) 27 to 28 Vac Fits 1/2" electrical k.o. UL 1015, 18 AWG* 8 inches 5 years *X085AAA, X375DAC have 14 AWG secondary wires. WIRE COLORS PRIMARY WIRES , COMMON BLACK 120 Vac WHITE 208 Vac RED 240 Vac 277 Vac ORANGE YELLOW 480 Vac GREY Threaded for conduit nut STANDARD SECONDARY WIRES BLUE 24 Vac BROWN OR WHITE 24 Vac 120 Vac Blk/Wht 120 Vac Primary of 24 V isolation transformers = Red/Red Colors refer to the transformer wiring, not the external circuit. CENTER TAP SECONDARY WIRES BLUE 24 Vac BROWN 12 Vac Blk/Wht 0 Vac 319 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Power Sources | X Series ORDERING INFORMATION MODEL VA PRIMARY VOLTAGE (VAC) SECONDARY VOLTAGE (VAC) CURRENT LIMITING METHOD CLASS MOUNTING STANDARD X020AAA X020ACA 20 X020ADA X040AAA X040AAB X040ACA X040ADA 40 X040AMB X040BNA X040BPC X050BAA X050BAB X050BCA X050BGB X050CAA X050CBA X050CBB X050CCA X050CEB 50 X050CEG 120 277 24 120 120 277 24 120/208/240/277 120/208/240 24 120 120 277 208/240 120 120/240/277/480 120/240/277/480 277 208/240/277/480 208/240/277/480 X050CHA 120/208/240/480 X050CHB 120/208/240/480 X050CNA 120/208/240 X050CNB 120/208/240 X050COA 120/208/240/277/480 X050COB 120/208/240/277/480 X050DLB 220 X075CAA 120 X075CAB X075CBA 75 120 120/240/277/480 X075CHA 120/208/240/480 X085AAA 85 120 X100CAA 120 X100CAB 120 X100CBA 120/240/277/480 X100CBB X100CBE 99 120/240/277/480 120/208/277/480 X100CHB 120/208/240/480 X100CKB 480 X100CLB 220 X150CAA 150 120 X175BAB X175CAB 175 120 120 X240DAA 240 120 X375DAC 375 120 CENTER TAP X020APC 20 24 X040BQC 40 120/208/240 X100CRC 100 120/240 24 12/24 24 120 24 120 24 12/24 Inherent Inherent Inherent Inherent Inherent Inherent Inherent Fuse Fuse Fuse Fuse Fuse Fuse Fuse Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker None Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Inherent Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker Fuse Circuit Breaker None None 2 2 General 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 General General 2 2 2 2 2 2 2 2 2 2 2 General 2 2 2 2 2 2 General 2 General General General General General 1HUB+FT 1HUB+FT 1HUB+FT 1HUB+FT 2HUB+FT 1HUB+FT 1HUB+FT 2HUB+FT 1HUB+FT Foot 1HUB+FT 2HUB+FT 1HUB+FT 2HUB+FT 1HUB+FT 1HUB+FT 2HUB+FT 1HUB+FT 2HUB+FT Plate, 90° Sec Elbow 1HUB+FT 2HUB+FT 1HUB+FT 2HUB+FT 1HUB+FT 2HUB+FT 2HUB+FT 1HUB+FT 2HUB+FT 1HUB+FT 1HUB+FT 1HUB+FT 1HUB+FT 2HUB+FT 1HUB+FT 2HUB+FT Plate 2HUB+FT 2HUB+FT 2HUB+FT 1HUB+FT 2HUB+FT 2HUB+FT 1HUB+FT Foot Inherent 2 Fuse 2 Circuit Breaker 2 Foot Foot 1HUB+FT SEPARATED PRIMARY & SECONDARY UL CE L W H A B WIRES · · 2.3 1.9 2.6 1.59 1.69 · · 2.3 1.9 2.6 1.59 1.69 · · 2.3 1.9 2.6 1.59 1.69 · · 2.7 2.2 2.9 1.98 1.81 · · · 2.7 2.2 2.9 1.98 1.81 · · 2.7 2.2 2.9 1.98 1.81 · · 2.7 2.2 2.9 1.98 1.81 · · · 2.7 2.2 2.9 1.98 1.81 · · 2.7 2.2 2.9 1.98 1.81 · · · 2.7 2.2 2.9 1.98 1.81 · · 2.8 2.2 2.9 2.06 1.81 · · · 2.8 2.2 2.9 2.06 1.81 · · 2.8 2.2 2.9 2.06 1.81 · · · 2.8 2.2 2.9 2.06 1.81 · · 3.5 2.5 3.1 1.91 2.03 · · 3.5 2.5 3.1 1.91 2.03 · · · 3.5 2.5 3.1 1.91 2.03 · · 3.5 2.5 3.1 1.91 2.03 · · · 3.5 2.5 3.1 1.91 2.03 · · · 3.5 4.0 4.0 3.38 3.38 · · 3.5 2.5 3.1 1.91 2.03 · · · 3.5 2.5 3.1 1.91 2.03 · · 3.5 2.5 3.1 1.91 2.03 · · · 3.5 2.5 3.1 1.91 2.03 · · 3.5 2.5 3.1 1.91 2.03 · · · 4.3 2.5 3.1 2.70 2.00 · · · 2.8 2.2 2.9 2.06 1.81 · · 3.9 2.5 3.1 2.31 2.03 · · · 3.9 2.5 3.1 2.31 2.03 · · 3.9 2.5 3.1 2.31 2.03 · · 3.9 2.5 3.1 2.31 2.03 · · 3.2 3.8 3.2 2.2 3.14 · · 4.1 2.5 3.1 2.51 2.03 · · · 4.1 2.5 3.1 2.51 2.03 · · 4.3 2.5 3.1 2.70 2.03 · · · 4.3 2.5 3.1 2.70 2.03 · · 4.3 4.0 4.0 3.38 3.38 · · · 4.3 2.5 3.1 2.70 2.03 · · · 4.1 2.5 3.1 2.51 2.03 · · · 4.1 2.5 3.1 2.51 2.03 · · · 3.5 3.8 3.2 2.08 3.26 · · · 4.1 3.8 3.2 3.19 3.14 · · · 4.1 3.8 3.2 3.19 3.14 · · · 3.7 3.8 4.5 3.24 3.18 · · · 4.3 3.8 4.5 3.83 3.18 · · · 2.3 1.9 2.6 1.59 1.69 · · · 2.7 2.2 2.9 1.98 1.81 · · · 4.3 2.5 3.1 2.70 2.03 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 320 INDEX 02 .........................................................................120 3x0 .......................................................................103 220x ....................................................................... 99 228x ....................................................................... 99 250x .....................................................................100 380 .......................................................................101 A A7810 .................................................................... 57 A8332-8F2D ........................................................ 59 A8810 .................................................................... 57 A8911-23 ............................................................. 61 AA01 ...................................................................... 93 AA04 ....................................................................205 AA05 ....................................................................179 AA06 ....................................................................179 AA07 ....................................................................179 AA10 ....................................................................205 AA11 ....................................................................179 AA12 ....................................................................179 AA13 ....................................................................179 AA14A .................................................................179 AA18 ....................................................................179 AA19 ....................................................................179 AA20 ....................................................................179 AA22 ....................................................................205 AA24 ....................................................................205 AA25 ....................................................................205 AA26 ...................................................................... 93 AA27 ...................................................................... 93 AA28 ...................................................................... 93 AA29 ...................................................................... 93 AA32 ...................................................................... 93 AA35 ...................................................................... 93 AA36 ...................................................................... 93 AA37 ...................................................................... 93 AA38 ...................................................................... 93 AA39 ...................................................................... 93 AA40 ...................................................................... 93 AA41 ...................................................................... 93 AA43 ....................................................................179 AA45 ....................................................................179 AA49 ....................................................................179 AA50 ...................................................................... 93 AA56 ....................................................................179 AA64 ....................................................................205 AA68 ....................................................................179 AA69 ....................................................................179 AA70 ....................................................................179 AE001 .................................................................... 69 AE004 .................................................................... 69 AE006 .................................................................... 69 AE012 .................................................................... 69 AE013 .................................................................... 69 AE014 .................................................................... 69 AFS-460 ..............................................................161 AG01 .............................................................. 85, 87 AG01E ............................................................ 85, 87 AG02 .............................................................. 85, 87 AGAE ..................................................................... 85 AGPE ..................................................................... 87 AH01 ...................................................................279 AH02/03/04 ........................................................ 69 AH06 ............................................................69, 279 AH11 ..................................................................... 69 AH27 ...................................................................279 AL ........................................................................... 51 AV01 ................................................... 69, 279, 313 AV02 ................................................... 69, 279, 313 AV05 .............................................................69, 313 B B142 ....................................................................113 B3000 ..................................................................113 BL ............................................................................ 51 C CBLxxx ........................................................... 35, 69 CDE ........................................................................ 81 CDL ........................................................................ 79 CL ........................................................................... 51 CRLSxx .................................................................. 83 CW2 ....................................................................... 73 CW2 Protocol ..................................................... 75 CWE2 ..................................................................... 77 CWV2 .................................................................... 77 E E2x FLEX ............................................................... 19 E2x System Calibrated .................................... 21 E5xxxA .................................................................. 25 E30 ......................................................................... 35 E31 ......................................................................... 35 E31CTDB ....................................................... 35, 69 E31CTx ........................................................... 35, 69 E34x ....................................................................... 33 E50 ......................................................................... 23 E51 ......................................................................... 23 E681x .................................................................... 43 E681x-5A .............................................................. 49 E682x .................................................................... 43 E683x .................................................................... 47 E8951 .................................................................... 65 EA20 ....................................................................273 Electromagnetic Series .................................105 EP2 .......................................................................165 EP3 .......................................................................163 F FC-5000 ..............................................................117 G GPS ........................................................................ 91 GWN ...................................................................... 85 GWNP ................................................................... 87 H H5xx ....................................................................275 H6ECM05 ...........................................................253 H11D ...................................................................247 H120 ....................................................................277 H221 ....................................................................263 H221SP ...............................................................263 H300 ....................................................................239 H308 ....................................................................241 H321 ....................................................................263 H321SP ...............................................................263 H421 ....................................................................263 H421SP ...............................................................263 H600 ....................................................................239 H606 ....................................................................245 H608 ....................................................................241 H609 ....................................................................243 H614 ....................................................................249 H622-10 .............................................................265 H622-20 .............................................................265 H623-10 .............................................................267 H623-20 .............................................................267 H681x .................................................................... 41 H701 ....................................................................241 H706 ....................................................................245 H708 ....................................................................241 H709 ....................................................................243 H709HV ..............................................................243 H720 ....................................................................251 H721HC ..............................................................261 H721LC ...............................................................261 H722HC ..............................................................265 H722LC ...............................................................265 H723HC ..............................................................267 H723LC ...............................................................267 H730 .....................................................................255 H735 ....................................................................257 H738 ....................................................................257 H739 ....................................................................259 H740 .....................................................................255 H748 ....................................................................257 H749 ....................................................................259 H750 ....................................................................255 H758 ....................................................................257 H800 ....................................................................239 H800HV ..............................................................239 H800NC ..............................................................239 H806 .....................................................................245 H808 ....................................................................241 H809 ....................................................................243 H822 ....................................................................265 H822-20 ..............................................................265 H900 ....................................................................239 H904 .....................................................................251 H906 ....................................................................245 H908 .....................................................................241 H909 ....................................................................243 H909HV ..............................................................243 H921 ....................................................................261 H922 ....................................................................265 H923 ....................................................................267 H930 .....................................................................255 H931 ....................................................................269 H932 ....................................................................271 H934 ....................................................................251 H938 ....................................................................257 H939 ....................................................................259 H940 ....................................................................255 H948 .....................................................................257 H949 ....................................................................259 H950 ....................................................................255 H952 ....................................................................271 H958 ....................................................................257 H959 ....................................................................259 H971 ....................................................................273 H971SP ...............................................................273 H8163 ................................................................... 27 H8822 ................................................................... 55 H8932 ................................................................... 63 H8936 ................................................................... 63 H922030A .........................................................265 321 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com Index H922060A .........................................................265 H922120A .........................................................265 HD ........................................................................131 HED ...................................................................... 135 HEW .....................................................................129 HN ........................................................................133 HO ........................................................................131 HP .........................................................................133 HS .........................................................................137 HW2 .....................................................................125 HW2 Protocol ...................................................127 L LC-KIT ..................................................................151 LD310 ..................................................................141 LD1000 ...............................................................141 LD1500 ...............................................................143 LD2100 ...............................................................143 LD5200 ...............................................................145 LDRA6 .................................................................141 M MSB ......................................................................211 MSC .....................................................................209 MX1B ...................................................................147 N NSC ......................................................................149 Nutating Disc Series ......................................109 P PASxx ..................................................................159 PD .........................................................................177 PG .........................................................................175 PH .........................................................................173 PS ............................................................... 279, 317 PW ........................................................................167 PW2 ......................................................................169 PWR .....................................................................171 PX3 .......................................................................157 Q QSE ......................................................................121 S SC .........................................................................149 SCT ......................................................................... 45 SD .........................................................................147 SDI .......................................................................... 97 SD-R01 ................................................................147 T TA .........................................................................199 TB .........................................................................195 TC .........................................................................189 TD .........................................................................191 TDDA ...................................................................191 TE ..........................................................................187 TF ..........................................................................191 TFX5000 .............................................................107 TG .........................................................................191 TI ...........................................................................104 TID ........................................................................193 TIG ........................................................................193 TIH ........................................................................193 TIW .......................................................................193 TJ ..........................................................................197 TK .........................................................................191 TO .........................................................................201 TP .........................................................................187 TRA ......................................................................195 TS ..........................................................................189 Turbo ...................................................................111 TW2 .....................................................................183 TW2 Protocol ...................................................185 TZ .........................................................................203 U U002-000x ........................................................... 69 U004 ...................................................................... 45 U006-0024 ........................................................153 U006-0026 ........................................................153 U006-0030 ........................................................153 U006-0031 ........................................................153 U006-0032 ........................................................153 U006-0033 ........................................................153 U006-0035 ........................................................153 U006-0037 ........................................................153 U006-0084 ........................................................153 U013-0010 .......................................................... 61 U013-0011 .......................................................... 59 U013-0012 .......................................................... 67 U013-0013 .......................................................... 67 U013-0015 .......................................................... 67 UG-7-A60 Uniguard ......................................... 89 V V100 ....................................................................285 V100D .................................................................285 V100DC ..............................................................285 V101 ....................................................................287 V101D .................................................................287 V102 ....................................................................287 V103 ....................................................................287 V120 ....................................................................291 V121 ....................................................................293 V122 ....................................................................293 V123 ....................................................................293 V200 ....................................................................285 V200D .................................................................285 V201 ....................................................................287 V201D .................................................................287 V220 ....................................................................291 V221 ....................................................................293 V222 ....................................................................293 V223 ....................................................................293 V300 ....................................................................289 V320 ....................................................................295 V321 ....................................................................297 V400 ....................................................................289 V420 ....................................................................295 V421 ....................................................................297 V645 ....................................................................299 Veris Sensors App ...........................................157 VFXP ....................................................................157 VIC-VC3xxxE5000 ...........................................225 VIC-VH7200 .......................................................227 VIC-VT7200 .......................................................215 VIC-VT7300 .......................................................217 VIC-VT7600 .......................................................221 VIC-VT8350 .......................................................219 VIC-VT8650 .......................................................223 VIC-VTR835x0A5x ...........................................225 VMD1B-C ...........................................................301 VMD1B-F ............................................................301 VMD2B-C ...........................................................303 VMD2B-F ............................................................303 VMD3B-C ...........................................................305 VMD3B-F ............................................................305 VMD4B-C ...........................................................307 VMD4B-F ............................................................307 VN2000 ...............................................................115 VS861 ..................................................................309 VTD ......................................................................311 VZ7000 ...............................................................229 VZ8250 ...............................................................231 X X ............................................................................319 800.354.8556|+1 503.598.4564|sales@veris.com|intl@veris.com|veris.com 322 VALUES WE BELIEVE IN OUR PRODUCTS AND WE VALUE OUR RELATIONSHIPS. Veris understands that consistency and reliability are important to our customers. That's why we strive to deliver excellent products and friendly expertise to help our customers get the job done right the first time. TEAM NEED A FRIEND IN THE ENERGY AND ENVIRONMENTAL SENSORS BUSINESS? WE'VE GOT YOUR BACK. Our customer service and sales teams are passionate about building long-lasting relationships and providing a great experience. Our friendly and dedicated customer service and sales team is just a phone call or email away. USA & CANADA SALES Phone: 800-354-8556 Email: sales@veris.com INTERNATIONAL SALES Phone: +1 (503) 598-4564 Email: intl@veris.com GENERAL CONTACT Phone: 800-354-8556 U.S. & Canada Fax: 503-598-4664 TERMS & CONDITIONS OF SALE By purchasing products from Veris Industries, LLC. (referred to as, "Veris," "us," "we," and "our"), whether through our website www.veris.com (the "Website") or otherwise (e.g., placing an order via telephone, facsimile, mail, or electronic transmission), you, on behalf of yourself and any entity you represent, if applicable (referred to as "you" or "Purchaser"), acknowledge that (1) all of the following terms and conditions ("Sales Terms") apply to every purchase; (2) these Sales Terms supersede any conflicting terms in any other purchase order, acknowledgement, agreement, or document, unless you and Veris have negotiated a separate master sales agreement that has been signed by both Veris and Purchaser; (3) these Sales Terms form a legally-binding agreement between you and Veris; and (4) if acting on behalf of an entity, you must have, and you represent and warrant that you have, full authority to bind your entity to these Sales Terms. Please read these Sales Terms carefully. EFFECTIVENESS OF SALE & DELIVERY Title transfers to Purchaser upon delivery to carrier. Purchaser bears all risk and transportation costs in accordance with INCOTERMS 2010, EXW. Packaging will be designed by Veris with the intent of protecting the product during shipment. Delivery dates are estimated only. In no event will Veris be liable for any damages of any kind, direct or indirect, in the event of delay of delivery. CANCELLATION POLICY If your order is for standard products shipped from stock at quantities less than LOQ (Large Order Quantity), you can cancel your order at any time prior to shipment without charge. Upon receipt of a purchase order, Veris will proceed to facilitate the manufacture and shipment of that order. In doing so, investment of materials and labor is made in the order. Therefore, if you cancel an order that exceeds the LOQ or is customized to your specifications, cancellation of that order can result in a loss to Veris. Therefore, by placing an order for quantities in excess of LOQ or for custommade products, you are making a commitment to pay Veris for any investments of labor and materials that are made to fulfill that order (LOQ's available upon request). If you cancel such an order prior to shipment, with respect to any unfinished goods, Veris will bill for labor and material costs already incurred; with respect to finished goods, we will ship those products and bill for the originally agreed upon purchase price plus shipping. After shipment, cancellation is no longer available; instead, please refer to the returns policy listed below in the Returns section of these Sales Terms. LIMITED WARRANTY FOR MOST PRODUCTS Subject to the conditions and restrictions described below, Veris warrants to Purchaser that any product sold by Veris, except for products described in "Products Sold Without Warranty" below, shall be free from material defects in design, materials, or manufacturing for the period shown on the current datasheet for that product or, if the current datasheet does not specify a warranty period, for a warranty period of 5 years, in each case beginning from the delivery date; provided, however, that the warranty shall not extend to ordinary wear and tear, or to normally replaceable components (e.g., batteries and humidity sensor elements). During the warranty period, Veris may at our sole discretion, repair, replace, or refund the purchase price (less depreciation) of any product deemed by us to have a defect, with no charge to Purchaser for any warranty repair or replacement. Purchaser will pay costs of shipping related to repair and replacement of any defective product. THIS WARRANTY IS PURCHASER'S EXCLUSIVE REMEDY FOR ALL CLAIMS AGAINST VERIS. This warranty shall remain in full force and effect for the warranty period, provided that all of the product: (1) was installed, operated, and maintained properly, under normal use conditions, and in accordance with the product instructions; (2) has not been abused or misused; and (3) has not been repaired, altered, or modified outside of Veris' authorized facilities. This warranty shall become null and void in the event any of the foregoing conditions is not satisfied. This warranty provides specific legal rights that may be varied by local laws. VERIS IS PROVIDING THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO OTHER WARRANTIES OR REPRESENTATIONS, STATUTORY OR OTHERWISE, EXPRESS OR IMPLIED, OR ARISING BY USAGE OR TRADE, OR OTHERWISE, EXCEPT THE LIMITED WARRANTIES SET FORTH HEREIN OR IN THE DOCUMENTATION OR DATA SHEET FOR A PRODUCT. To the extent of any inconsistency between the terms of this limited warranty and any special, extended, or optional warranty or service program purchased with the product (e.g., the optional warranty periods available for the CWVS series products), the terms of such special, extended, or optional warranty or service program will control. PRODUCTS SOLD WITHOUT WARRANTY All products that are marked "as is," "with all faults," no warranty," or with similar language are sold with no representations, warranties, or indemnities of any kind, statutory or otherwise, express or implied, or arising by trade. Without limiting the generality of the foregoing, such products are sold without any warranty of merchantability, fitness for a particular purpose, or non-infringement. LIMITATIONS OF LIABILITY Veris shall not be liable for any consequential, incidental, indirect, exemplary, special, punitive, or multiple damages arising in any way from the website or the products, even if Veris has been advised of the possibility of such damages. Veris' total liability for all claims shall be limited to the price paid for its product. The limitation of Veris' liability is applicable to any and all claims or theories of recovery asserted by purchaser, including, without limitation, breach of contract, breach of warranty, expressed or implied, strict liability in tort or negligence, or in the event that you claim, allege, or otherwise assert that any loss or damage is attributable to the negligence of Veris. RETURNS Valid returns are accepted with a Returned Material Authorization (RMA) number assigned by Veris. To request an RMA, please contact Customer Service at 1-800-354-8556 toll-free in the USA and Canada, or +1 503-598-4564. All returns and warranty claims must be delivered to Veris, attention customer service with the assigned RMA number visible on the package. Standard products in unopened condition (except evaluation orders) can be returned to stock subject to a charge of 15% for up to 90 days from original shipment. Items that have been opened or held for 90 to 180 days after the date of shipment, may be accepted for return subject to a 30% restocking charge. Items may not be returned after 180 days from the date of shipment. Products returned for credit must be in saleable condition. If the product has been modified, damaged, or installed, or is otherwise not in saleable condition, the product is not returnable. Products that have been customized in any way for Purchaser's specifications (including those having electrical modifications or private labeling) and products that are marked "FINAL SALE," "NOT RETURNABLE," or with a similar statement may only be returned for warranty service (if such products have a warranty). PAYMENT Unless different payment terms are agreed to in a written instrument executed by both Veris and Purchaser, payment terms for all purchases are 2%-10/NET 30 days for delivery to the US or Canada, net 30 days to all other destinations. OneSource Rewards points cannot be applied to open invoices, or to any shipping costs. Purchaser agrees to pay finance charges of 18% per annum on any past due amount. Purchaser further agrees to pay any court costs, collections fees or attorney fees if legal action must be taken on any unpaid balance. INFRINGEMENT INDEMNITY Veris shall defend Purchaser from any suit or proceeding brought against Purchaser to the extent it is based on a claim that a Veris product infringes any USA copyright, trademark or patent. This obligation shall be effective only if Purchaser has made all payments then due hereunder and if Veris is notified promptly in writing and given authority, information, and assistance at Veris' expense for the defense of the same. In the event the use of such product by Purchaser is enjoined in such a suit, Veris shall, at its expense, and at its sole option, either (a) procure for the Purchaser the right to continue using such product (b) modify such product to render it non-infringing (c) replace such product with non-infringing product, or (d) refund the purchase price (less depreciation) and the transportation and installation costs of such product. Veris will not be responsible for any compromise or settlement made without its written consent. The foregoing states the entire liability of Veris for patent, trademark, copyright or other intellectual property infringement or misappropriation. In no event shall Veris be liable for, and Purchaser agrees to defend, indemnify, and hold Veris harmless from, any third party claim of infringement, misappropriation, or other violation of a third party intellectual property right to the extent such claims is based on the use of a Veris product for a purpose other than that for which it was sold by Veris or contrary to the written instructions or other documentation for such product, or arises from specifications furnished to Veris by or on behalf of Purchaser, or arises from any modification to the product made by or on behalf of Purchaser. For complete terms & conditions, visit veris.com USA & CANADA SALES Phone: 800-354-8556 Email: sales@veris.com INTERNATIONAL SALES Phone: +1 (503) 598-4564 Email: intl@veris.com CORPORATE HEADQUARTERS & RECEIVING 12345 SW Leveton Dr Tualatin, OR 97062 USA GENERAL CONTACT Phone: 800-354-8556 U.S. & Canada Fax: 503-598-4664 www.veris.comAdobe InDesign 16.0 (Windows) 3-Heights™ PDF Optimization Shell 6.3.1.5 (http://www -tools.com)