CI SfB (4-) Nn2 ONDULINE Classic sheets

Design and installation manual Complementary leaflet to the Onduline BBA instructional film available online BRITISH BOARD OF AGREMENT CERTIFICATE NO. 87 / 1823. Onduline fixing guide: Contents: 01 Introduction Onduline sheet specification Identifying top surface of sheet 02 Roof design ...

ONDULINE Classic sheets - Roofing Megastore

Design and installation manual. Complementary leaflet to the Onduline instructional film available online. BBABRITISH. BOARD OF. AGREMENT. CERTIFICATE ...

ONDULINE Classic sheets CI SfB (4-) Nn2 www.onduline.co.uk The attractive durable lightweight corrugated sheet roofing system Design and installation manual ...

PDF Bitumen-Corrugated-Sheets-Trims-Onduline-Black-Bitumen-Corrugated-Roof-Sheet-950mm-x-2000mm-x-3mm~O0615 240039 TECH 4
CI SfB

(4-) Nn2

ONDULINE® Classic sheets®

BBA BRITISH BOARD OF AGREMENT
CERTIFICATE NO. 87 / 1823

The attractive durable lightweight corrugated sheet roofing system
Design and installation manual
Complementary leaflet to the Onduline instructional film available online

®
www.onduline.co.uk

Onduline fixing guide:
This guide provides comprehensive design and installation guidance, you can either select & click on the specific information you require from the index below or view this guide and instructional video in full.

Contents:

01 Introduction Onduline sheet specification
Identifying top surface of sheet 02 Roof design
Roof structure
Roof types and terminology
Recommended tool kit 03 Roof construction
Roof support options
Support to sheet
Sheet laps
Fixings to sheet
Sheet coverage 04 Preparation
Setting the roof out
Fixing purlins or decking
Insulation and underlays 05 Fixing skills
Marking out sheets
Cutting with handsaw
Cutting with power saw
Cutting with tinsnips
Cutting up length of sheet 06 Onduline fixing types
Plastic capped nails
Safetop nails / screws
Universal drill screw fixing 07 Fixing sheets
Sheet side and end laps
Corrugation end laps
Corrugation side lap
Sheet selection
Sheets laid in broken bond 08 Fixing details:
Eaves detail.
Eaves / verge detail
Eaves tray option
Ventilator comb
Corrugation filler 09 Verge detail
Nailed verge
Lapped verge
Onduline verge pieces 10 Ridge duo pitched roof
Ridge purlin positioning
Onduline ridge piece fixing
Ridge trimmed laps option
Ridge finial

11 Ridge mono pitch roof Using Onduline verge piece
Ridge verge abutment
Using Onduline ridge piece 12 Wall cladding rainscreen
Cladding options 13 Valley detail
Valley support structure / lining
Marking sheet to valley
Cutting and positioning sheet
Valley saddle detail 14 Hip detail
Hip support structure
Fitting sheet to hip
Laying ridge pieces to hips
Hip ridge abutment
Trimming hip ends 15 Onduline roof window
Fixing roof window 16 Onduline roof ventilators
Fixing roof ventilators 17 End wall abutments
Fixing end wall abutment
Cover flashing 18 Side wall abutment
Fixing end wall abutment
Cover flashing 19 Curved roof application
Support structure
Fixing sheets to curve
Sheet laps on curved roof 20 Onduline Plastics
Sheet selection
Eaves detail
Sheet fixings 21 General design notes
Onduline design notes 22 Roof oversheeting system
Warm roofs
Cold roofs
Ondutile tile underlay system 23 General design notes
Onduline

Onduline® Classic
Corrugated bituminous sheet
roofing and cladding system

A tradition of quality
The Onduline Group is the worlds largest producer of bituminous corrugated roofing products, selling to over 120 countries worldwide.

Onduline classic sheet specification (nominal )

· Sheet size: 2.000 x 0.950 m

· Corrugation size: 95 x 38 mm

· Thickness: 3 mm (nominal)

· Lightweight: 6.4kg per sheet (nominal)

· BBA Product Certification

· Easy to handle, cut, shape and fix

· 15 year weather proofing guarantee subject to terms and conditions
· Excellent colour retention properties

Red Brown

· Withstands windspeeds of up to 120mph (192kph).

Green

· Lightweight, only 6.4 kg per sheet · High thermal and sound insulation

Black

· Does not rust, or contain Asbestos

· ISO 9001:2008 Quality Management Standard

· ISO 14001: 2004 Environmental Management

Identifying top surface of sheet

Take care to fix Onduline sheets the correct way up,

the underside is easily identified by its dimpled rough

surface finish, whilst the top of the sheet has a

smoother textured finish

Warning: Check that your sheet and accessories are

genuine Onduline products. Failure to do so can result

in lower quality roof performance and invalidate the

Onduline roofing system guarantee.

Upper sheet surface

Lower sheet surface

Roof design:

Roof structure
It really is worth taking the time to first check your roof and carefully set out the design for the support structure on your project. It will save you time and money!
New build project:
Just follow the information in this leaflet to create a durable low maintenance roof. Existing roofs: Survey your roof structure as this will allow you to decide if it requires maintenance, upgrading or strengthening prior to fixing the Onduline sheets. Make note of the roof construction normally built using purlins or boarded roof deck laid onto a timber portal or trussed rafter roof structure.
Warning: Check that existing purlins are fixed at centres suitable for fixing Onduline sheets onto; as many existing roofs do not offer sufficient support and failure to increase the support structure can result in sheet deformation and a significant shortening of the roofs service life.

Roof types and terminology
Duo-pitch roof:

Hipped roof:
Hip: Verge: Barge
board:

Mono-pitch roof:

Ridge: Valley:

Side wall abutment:

End wall abutment:

Fascia board:
Roof decking: Purlins / battens: Eaves:

Roof framing & design:

Rafter or trussed roof construction:

Portal framed roof construction supporting purlins:

Recommended tool kit

5

6

7

4

8

9

1

2

3

11

10

Conventional trussed roofs:
Roof design is based on triangulated frames which can be in the form of traditional framed structures or constructed from trussed roof frames.
Portal framed roof structures:
Timber frame structures often use a portal frame construction which supports purlins to which the roof covering material is affixed.

1 Hammer:

7 Course bladed hand saw:

2 Tin snips:

8 Protective gloves:

3 Roofers knife:

9 Protective glasses:

4 Tape measure:

10 Electric rotary or skill saw:

5 Spray lubricating oil: 11 Protective hard hat:

6 Straight edge:

Return to Contents

Onduline

Introduction

Fixing Onduline sheets is a simple process just follow the simple three step instructions set out in the tables below:

Roof support and fixing specification
1 Step 1: First measure the slope of your roof: To do this simple use a protractor or inclinometer or alternatively calculate the roof slope using the roof slope gradient.
2 Step 2: Select one of the three fixing options set out below that matches the slope of your roof either: a: b: or c:

3

Step 3: Then just follow the fixing instructions described below the appropriate fixing option; a: b: or c: They detail the correct support required below the sheets, corrugation end and side laps and finally the sheet fixings.

a: b: c:

15o degrees or greater Support to sheets
61cm

10 to 15o degrees
45cm

10 to 5o degrees
Roof deck

Purlins should be fixed at maximum centres of 61 cm. At the eaves allow for a 50cm sheet overhang when positioning the first purlin from the eaves.

Purlins should be fixed at maximum centres of 45 cm. At the eaves allow for a 50cm sheet overhang when positioning the first purlin from the eaves.

A fully supporting decked roof should be laid. At the eaves allow for a 50cm sheet overhang when positioning the first purlin from the eaves.

a:
15o degrees or greater Sheet laps
Sheet end lap 17 cm

b:
10 to 15o degrees
Sheet end lap 20 cm

c:
10 to 5o degrees
Sheet end lap 30 cm

1 Corrugation side lap
Lay the sheets with: 17cm sheet end lap Single corrugation side lap
Sheet fixings

1 Corrugation side lap
Lay the sheets with: 20cm sheet end lap Single corrugation side lap

2 Corrugation side lap
Lay the sheets with: 30cm sheet end lap Double corrugation side lap

Nail every corrugation along of the eaves, either side of the vertical laps and every other corrugation on the intermediate purlins in a offset pattern.

Nail every corrugation along of the eaves, either side of the vertical laps and every other corrugation on the intermediate purlins in a offset pattern.

Nail every corrugation along of the eaves, either side of the vertical laps and every other corrugation on the intermediate purlins in a offset pattern.

Sheet coverage

Sheet size: 2.000 x 0.950 m

Corrugation:

95 x 38 mm

Fixings per sheet: 20

Sheet coverage:

1.56 m2

Sheet cover length: 1,830 m

17cm sheet end lap

Sheet cover width: 0.855 m

One corrugation side lap

Sheet size: 2.000 x 0.950 m

Corrugation:

95 x 38 mm

Fixings per sheet: 25

Sheet coverage:

1.54 m2

Sheet cover length: 1,800 m

20cm sheet end lap

Sheet cover width: 0.855 m

One corrugation side lap

Sheet size: 2.000 x 0.950 m Corrugation: 95 x 38 mm Fixings per sheet: 20

Sheet coverage:

1.29 m2

Sheet cover length: 1,700 m

30cm sheet end lap

Sheet cover width: 0.760 m

Two corrugation side lap

Return to Contents

Preparation:
Setting the roof out
Fix sheets at the opposite end of the roof from the prevailing winds. Then commence every other sheet course with a half sheet forming a broken bond sheet layout to avoid a 4 ply sheet thickness at sheet corners.
Fixing purlins or decking

1

56 2

9 10 11 78

34

Purlin size Purlins must be of sufficient size to give support between the rafters. Consult the table on page 19 for guidance on the size of purlins required.

Fixing Purlins Take care to set the purlins out to the correct centres and then either nail or screw them to the trusses or rafters.

Fixing decking Decking should be laid in a broken bond pattern fixed to a minimum of three purlins in accordance with the relevant B.S. and Codes of Practice.

Fixing to existing deck Check the thickness of the deck. You will need at least a 20 mm board to avoid the risk of the fixings penetrating the interior of the building.

Fixing Decking or Purlins On thin decks, additional roof deck can be overlaid; or alternatively fix purlins set to the correct centres screwed first at the verges externally.

Insulation and underlay membranes

Fixing Purlins to thin decks Then using a string line screw through the deck into the purlins from inside the building; securing the purlins onto the roof ready to accept the Onduline sheets.

Insulation upgrade The thermal performance of your building can be upgraded by laying insulation boards between the purlins, having first laid an Ondutiss membrane.

Onduline underlays The Ondutiss roofing and vapour permeable roof underlay range is designed for use below Onduline sheets. Select the membrane that matches your project needs.

Laying Ondutiss membranes Follow the Ondutiss product fixing instructions, this requires 10 cm roll end laps and fixing to the deck with 10 mm large headed clout nails at 150 mm centres.
Return to Contents

Fixing skills:
Onduline is designed to be simple to both handle and fix requiring a minimum of trade skills and equipment, just take the time to familiarise yourself with these basic skills and use the recommended tools and success is assured.
Fixing Skills - Cutting sheet

Marking out the sheet Carefully measure the size of the material required and mark out the line to be cut onto the sheet surface.

Cutting with handsaw Use a coarse bladed handsaw to cut Onduline sheets. Apply spray lubricating oil onto the saw to avoid the saw teeth from binding with bitumen.

Cutting sheet width Support the sheet cut ends and cut the sheet taking time to clean and lubricate the blade as required.

Cutting using power tool Support the sheet either side of the line to be cut taking care to allow the safe operation of power rotary circular or skill saw.

Cutting using power tool Always wear safety equipment and consult the manufacturers instructions for safe operation when using power tools.

Cutting using tinsnips First mark out the sheet or Onduline accessory. Cut with an oiled pair of tinsnips to form detailed shapes in the onduline material.

Cutting up corrugation. First mark out the line of the cut in the base of the sheet corrugation. Use a roofers knife to score the Onduline.

Cutting up corrugation. Next fold back the sheet along the cut / scored line to separate the cut sections of the sheet.

WARNING . Working on roofs at heights can
be hazardous. Always work from a secure ladder or platform and use the appropriate safety equipment. Guidance can be found in Health and Safety Guide HSG33 working on roofs.
Return to Contents

Plastic headed
Onduline fixings: Monobloc nails

The Onduline range of fixings allows the sheets to be easily fixed to a wide range of roof structures. Select the fixing matching your requirements from either Plastic headed nails, or Safetop nail (screw option) or the Onduline universal drill screw.

Safetop nails (+ Screw option)

Onduline sheet fixings

Universal screws

Fixing options Refer to a: b: or c: fixing specifications

Plastics capped Monobloc nails Onduline plastic headed nails are a cost effective solution for fixing the majority of roof types.

Plastic capped Monobloc nails Fix by striking the preformed Monobloc head with the hammer through the top of the corrugation. Note: You do not have to pre-drill the sheet.

Safetop nail fixing The safetop assemble features a heavier duty nail, use by nailing through the washer into the top of the sheet corrugation.

Safetop screw fixing Alternatively, you can replace the standard nail supplied with a proprietary screw; using the cap and washer, ideal for fixing the sheets to thin decked roofs.

Safetop washer cap. The safetop assemble is finished by clipping the cap onto the washer assemble. Note: If the cap has been displaced use sealant adhesive to secure.

Universal screws Onduline universal screws can be used on both timber and steel purlins. They feature a screw and integral weathering washer.

Universal screws. A chuck drill bit holder is used to retain a Phillips HEX insert bit required to drill the universal screw into the purlins. Note: Bit size 1/4" 25mm PH No2.

Universal screws. The screw is suitable for drilling into a wide range of standard steel pulins, we recommend you check its suitability prior to starting work by undertaking test fixings.

Return to Contents

Fixing Details:
To guarantee a professional roof follow the guidance in this section to create a well-founded and durable roof on your building.
Sheet side and end laps

17cm 20cm 30cm
Sheet end lap Mark out the correct sheet end laps on the sheet matching your roof slope as specified in the a, b. or c roof specifications set out above.

Sheet end lap

The cover width being either:

a: 150 degrees or greater: 17 cm.

b: 100 to 150 degrees:

20 cm.

c: 50 to 100 degree:

30 cm.

1 corrugation lap
Corrugation side lap Form a single corrugation side lap on options a and b: a: 150 degrees or greater. b: 100 to 150 degree.

2 corrugation lap
Corrugation side lap Form a double corrugation side lap for option c: c: 50 to 100 degree

Sheet selection Warning: Always check the sheets are the genuine Onduline Classic sheets. Beware of imitations!

Broken bond pattern When setting a roof out start alternate courses with a half sheet to form a broken bond pattern thus avoiding a 4 ply sheet thickness at edges of sheets.

Eaves fixing details

5cm

5cm

Onduline eaves detail Allow a nominal 5 cm overhang

Fixing sheet at Eaves Form a 5 cm sheet drip edge at the eaves. Remember to reduce the distance to the first purlin up from the eaves to allow for the sheet overhang at the eaves.

Eaves and Verge Ensure the sheets are positioned square to the line of the eaves and verge, first nailing the sheet edges (allowing for laps) to keep sheets square to the eaves line.
Return to Contents

Eaves fixing options

Eaves tray The versatile Onduline eaves tray can be used to reduce the sheet overhang at the eaves. It is also a component part of the Ondutile and Oversheeting systems.

Ventilator comb Fixed to the eaves and ridge it stops ingress of birds and large insects into the roof space, whilst maintaining a ventilation airflow into the roof space.

Corrugation filler Used to seal the corrugations at eaves and ridge from ingress of sand and dust into the roof space. Alternative ventilation provision should be made.

Verge fixing options

Onduline verge detail For a superior weathering detail

Nailed verge option Fix a verge barge board within the last corrugation then fold down the corrugation edge and nail using galvanised clout nails at 15cm centres.

Lapped verge option First align and fix the verge barge board with the purlins, then overlap the sheet corrugation by nominally 5mm secure by nailing the sheet at every purlin.

Onduline verge pieces For a superior weathering detail

Verge piece fixing First align and fix the verge barge board with the purlins, Then position preformed Onduline verge units with a 20cm end lap (ensure the end lap is secured).

Verge piece fixing Secure the verge units by nailing through the verge and top of the Onduline sheet corrugation on the roof and through the vertical upstands into the barge board.

Return to Contents

Ridge duo pitched roof detail

Ridge detail Providing assured weathering and ventilation into the roof.

Ridge purlin positioning Use a ridge piece to determine and mark the position of the purlin required to accept the ridge fixings. Its position is variable dependant on the roof slope.

Ridge purlin fixing Screw or nail the purlin into place onto the roof trusses. We recommend that purlins are also positioned to support the sheet ends at the ridge.

Ridge piece fixing Lay the Onduline preformed ridge units into position they are sufficiantly flexiable to allow the ridge to be formed to match variable roof slope.

Lapping ridge piece Ridges are fixed by aligning the preformed grooves (nominal end lap of 220mm), the ridges are laid from the opposite end of the roof from the prevailing wind.

Fixing ridge piece Mark a fixing line on the roof and secure the ridges by nailing every other corrugation ensuring the grooved ridge piece laps are secured either side of the lap.

Option. Trimmed laps A superior ridge line finish can be achieved by trimming the lower ridge piece to be lapped, this provides a smoother line to the ridge pieces once fixed.

Option. Trimmed laps To do this use a roofers knife to trim the edges of the end of the ridge piece to be overlaid.

Option. Trimmed laps Trim the ridge pieces on a bench then install on the roof. Always use a deep straight to cut against as a safeguard against the knife slipping.

Option. Trimmed laps Using the trimmed edge option when fixed in position the ridge end laps are less evident and a neater ridge line is established.

Finial ridge closure Terminate the ridge end by marking out and cutting a treated timber finial to match the ridge profile.

Fixing Ridge finial closure The finial is then simple fixed to the verge barge boards and finished to match the decorative finish applied to the verge barge boards.
Return to Contents

Mono pitched ridge using verge or ridge pieces

Mono ridge verge detail Using Onduline verge pieces and corrugation filler.

Mono ridge structure Mark out and fix a ridge facia board, incorporating a high level ventilation channel into the roof space providing a continuous 10mm air gap into the building.

Onduline eaves filler Position and lay Onduline corrugation filler onto the Onduline sheets to seal the corrugations from wind driven rain and snow at the eaves.

Fixing verge pieces. Next lay the verge pieces over the mono ridge abutment, compresing the corrugation filler by fixing into each corrugation.

Completing the fixing Complete the fixing by nailing rear of the verge trim onto the ridge fascia board at 15cm centres. Press the safetop caps onto the washer bases.

Overlay Verge abutment At verge and hip abutments the ridge section must always be laid onto the verge / hip section to weather the roof.

Mono pitch ridge detail Using Onduline ridge pieces to weather ridge detail.

Onduline ridge piece Alternatively Onduline ridge pieces can be used to seal a mono ridge abutment after first fixing an additional purlin to accept the ridge fixings.

Onduline ridge ventilation The corrugations provide a high level ventilation into the roof space. The ridge is nailed to every other corrugation and either side of the ridge end laps.

Wall cladding & rain-screen applications

Wall cladding fixing specification

The sheets can either be laid on a studded

Plywood frame (1) with a vapour permeable

membrane laid to the wall prior to fixing the

treated timber studding with high and low

ventilation provided to the sheet. Alternatively

the sheets can be laid on a timber studded

frame (2) with the purlins set at 61 cm centres.

1

2 However, if insulated boards are placed

between the purlins the spacing can be

opened to 90cm. Onduline sheets should not

be laid within 1 metre of ground level.

Return to Contents

Valley detail

Onduline valley detail Minimum 7.5 cm valley drainage

Valley support structure The support structure to the valley is constructed by first fixing trimming battens to the purlins, and lining with valley boards to provide a 7.5cm gutter depth.

Valley lining options The valley base can then be overlaid with metal or suitable roofing membrane weathering membrane to form a durable valley lining.

Fixing GRP valley lining Alternatively pre-formed GRP valley liners are laid between the purlin trimming battens and secured by nailing. underlay can be dressed over the upstands.

Onduline valley lining Another option is to use pre-formed Onduline valley lining pieces, these laid on fully supporting plywood valley boards positioned.

Fixing valley lining The Onduline units are secured to the purlins trimming battens by nailings at 20cm centres up the line of the gutter.

Marking sheet to valley Position the Onduline sheets up the line of the valley and mark out the cut line, allowing for a minimum of 4cm sheet drip edge into the valley gutter.

Cutting sheet Remove the sheets from the roof supporting either side of the required cut line, then use a mechanical saw to cut the sheets as required.

Positioning sheet The sheets are then positioned back on the roof, aligned square to the line of the roof sheets providing the minum of 4cm drip edge into gutter.

Fixing sheet to valley The sheets are fixed in place allowing for the correct sheet side and end laps. The fixings are secured up the line of the purlin trimming battens.

Fixing sheet to valley The fixings to the roof sheets can then be applied.

Valley saddle detail. a saddle weathering should be used to seal the valley lining at the ridge abutment, allowing the ridge pieces to be laid onto the roof.
Return to Contents

Hip detail

Hip detail Assured weathing detail

Hip support structure Position the Onduline sheets up the line of the hip and mark the line to be cut allowing a 5cm sheet drip edge at the eaves. Remove from the roof and cut.

Fixing the sheets to hip Reposition sheets back onto the roof, square to the line of the roof provide the correct side and end laps. A hip board will assist in this and also support the ridge units.

Aligning ridge pieces Position and carefully mark out a line to which the ridge pieces can be aligned up the hips. Start fixing the ridges from the eaves up the line of the hip to the ridge.

Fixing ridges to hip The ridges are fixed to the lines marked out on the sheets. Fixing through the ridge top of the sheet corrugation into each purlin up the roof hip.

Fixing ridges pieces The ridges are fixed by aligning the ridge piece preformed grooves (nominal end lap of 220mm), in accordance with the fixing specification.

Hip to ridge joint The ridges are cut into the line of the ridge board. The ridge units can then be overlaid and fixed to form the hip abutment.
Onduline roof window

Hip ridge abutment On exposed sites the lapped section between the hip and ridge pieces should be sealed with Onduline sealant adhesive.

Trim hip ends The hip ridge pieces can be finished at the eaves by trimming the ends to the line of the eaves using a saw or tinsnips.

Onduline roof window For illumination and ventilation.

Onduline roof window The front apron laps onto the lower sheet, this might require an extra short purlin to accept the front apron fixings.

Fixing Onduline window Complete by cutting and lapping the sheets onto the back and side window weathering aprons and then fix to purlins.
Return to Contents

Onduline roof ventilators

Onduline roof ventilators For assured roof ventilation.
End wall abutment

Basic verge detail Roof ventilators are available in two sizes to provide increased ventilation and should be used mid span on roof slope / lengths greater than 11m.

Onduline verge pieces The ventilators are fixed between the purlins. The apron is lapped over the lower sheet, with the integral side and back gutter aprons being lapped by next.

Onduline apron pieces For a superior weathering detail

Onduline apron fixing Use Onduline pre-formed apron flashing piece to seal end wall abutments. Lay the upstand against the wall and fix the front apron at each corrugation.

Side wall abutment detail
Side wall abutment Overlay at least one Onduline corrugations with a proprietary preformed abutment flashing dressed up the wall and fix through the top of corrugation.

Apron cover flashing To allow for differential movement between the wall and the roof sections always use a seperate wall cover flashing dressed into a prepared joint.
Upstand to wall To allow for differential movement between the wall and the roof sections always use a seperate wall cover flashing dressed into a prepared joint.

Side wall abutment Metal or preformed proprietary side wall abutments; or Onduband self-adhesive flashing tape are used to seal side wall abutments providing a minimum of 7.5 cm upturn against the wall and dressed over at least one full Onduline corrugation. Complete with a separate wall cover flashing.

Return to Contents

Curved roof detail

50 degrees

Dome

50 degrees

Full sheet
Onduline

used

to

cap

ridgePlate

line

Onduline Classic sheets

Purlin centres

Purlins Overlap 30cm
Important - For buildings with high humidity levels, see designers note.

Onduline fixing to curved roof: Onduline sheets can be formed to curved roofs. First check the sheet can be formed to the required radius. The support purlins at the ridge should be set at 42.5 cm centres as the pitch becomes shallow, the ridge must always be capped with a full Onduline sheet width. The purlin centres on the side cheeks of the roof can be widened to 61 cm. Fix Onduline ventilation units to the roof sides as required. Note: On buildings with high internal humidity levels close boarding; or roof decking must be used at the ridge and Ondutiss underlay membrane can be used with enhanced ventilation provision. Fixing sheets on curved roof: The sheets must always be laid with 2 corrugation side laps and 30 cm sheet end laps on the curved roof.

Sheet laid to roof curve The sheets are laid with 2 corrugation side laps and 30 cm sheet end laps on the curved roof, position the sheet square to the eaves and verge line.

Marking the sheet Mark out the sheet nail points on every corrugation along of the eaves, either side of the vertical laps, and every other corrugation on the intermediate purlins.

Fixing sheet at eaves In this instance we are using Onduline screw fixings securing the eaves line first. Secure the sheet edges first then work to the centre (allowing for laps).

Forming sheet to curve Use a timber batten to compress the sheet to the required roof curvature then mark out fixing points on the sheet.

Applying sheet fixings Maintaining pressure on the batten apply fixings to secure sheet in place, securing the sides of the sheet square to the verge line (allow for sheet laps).

Secure remaining fixings The remaining fixings can then be secured forming the sheet to roof curve.

30cm end lap

Curved roof mono ridge Onduline ridge and corrugation filler are used to seal mono ridge abutments, fix the sheet at every sheet corrugation and provide high level roof ventilation.

1 2 side lap
Sheet laps to curved roof Always provide a double corrugation sheet side lap and 30 cm sheet end lap on curved roof slopes to allow for possible deformation of the sheet laps.

Curved roof specifications The inherent flexibility of Onduline sheets make them ideal for curved roof projects. Our technical sales department can assist you with your project.
Return to Contents

Onduline Plastics:
Onduline Plastic sheets share the same Onduline profile and sheet dimensions and are accordingly simple to fix to your roof, providing top class light transmission provision into your building. Sheets are available in both crystal clear and opaque finishes and are available in PVC and Polycarbonate materials. Check out the website for full details on the full Onduline Plastics range.
Fixing plastic roof illumination sheets

Onduline plastics For a superior weathering and light tranmission properties.

Clear; or Opaque sheet? We offer two roof sheet options; opaque which tends to be easier to handle and clear which is more `brittle' to handle but offers `glass' clear light transmission.

Sheet side laps To avoid sheet discolouration under U.V. heat exposure always lap the Onduline sheet onto the plastic sheets on the sheet side laps.

Drip edge to eaves Allow for a 5 cm drip edge at the eaves. To protect against U.V. heat exposure discolouration to the plastic sheets, first paint any dark roof support elements white.

Marking fixing points Mark out the fixing points onto the plastic sheet in accordance with the Onduline sheet fixing instructions.

Pre-drilling fixing points Pre-drill the fixing holes with a 5.5mm drill to allow for thermal sheet movement around the fixings in service.

Fixings selection Use the same Onduline fixing matching the Onduline roof section, in this case we are using Onduline universal screws which are generally easier to apply to plastic sheets.

Applying fixings Carefully screw or nail the fixings into position. Note: it is important the fixings are not overtightened to allow for thermal movement in the plastic sheets.

WARNING . Only genuine Onduline Plastics
are recognised under the terms of the Onduline product guarantee. The Onduline plastics division will be pleased to assist with the roof illumination PVC, GRP and polycarbonate product range.

Return to Contents

Design notes:

Please check the website for additional product information, product and design data sheets.

General design notes

Timber Purlin roof design: Timber purlins should be of sufficient size to provide support the Onduline 95 x 38 mm sheet corrugation spanning charactisitics and associated roof loads between supports.
Note: The table below gives suggested minimum timber purlin sections for roof pitches over 150 including allowances for normal snow loadings.

Span

Typical timber section sizes for treated softwood purlins (on roof pitches above 150)

(m) 0.450 0.610 2.4 3.0 3.6 4.2 4.5 4.8 5.4 6.0 6.6

(mm) 38 x 25 50 x 50 38 x 75 38 x 100 38 x 125 44 x 150 50 x 150 50 x 160 63 x 175 63 x 200 75 x 200

Note: This table is prepared as a guide only in consultation with TRADA the British Timber Research and Development Association. However, design needs can vary according to roof layout and building regulations. Professional advice should always be sought for specific roof design applications.

Maintenance: To ensure a long life the roof should be cleared of leaves and debris and gutters cleaned regularly. Any branches in contact with the roof surface should be removed.
Fire classification limitations: Onduline sheets are not classified to External S.AA fire rating as required in UK Building Regulations for some classes of structure. In these instances they must be fixed on a fully supporting roof deck and the sheets coated with a proprietary `AA' surface paint treatment applied in strict accordance with the paint manufacturer's instructions.
Condensation: Onduline is highly resistant to the build-up of condensation. However, any single thickness roofing material is at risk of condensation formation. It can also be the case that during the winter month's water vapour present within the building can freeze to the underside of the sheets; this ice then melts as the roof warms in the morning forming water droplets which can drip off the sheets. Note: Consult the Condensation & Ventilation Data sheet for further information. Ventilation: A range of Onduline ventilation accessories are available to assist in the provision of high and low level ventilation which will reduce the risk of condensation formation.

Snow loadings: We recommend on buildings situated in exposed locations or situated in elevated regions subject to periodic high snow loading that Onduline sheets are fixed onto a roof deck. And the use of both enhanced vapour control measures and ventilation provision is incorporated.

Onduline roof renovation system

The light weight of the Onduline roofing system makes it ideal for Oversheeting existing failing and deteriorated fibre cement or steel pitched roof coverings. The system can be used in either cold or warm roof configurations. For detailed design specifications consult the Onduline roof renovation Oversheeting fixing guide.

Cold roof over sheeting
Fascia board Eaves tray Onduline sheets laid on purlins fixed to the support battens. Onduline support batten fixed to existing roof structure. Existing deteriorated corrugated roof covering. Existing purlin roof structure Cold roof over sheeting specification Determine the fixings required to secure the support battens to the existing roof support structure as required in conformity to British Standards & Codes of Practice. Note: The fixings must offer sufficient resistance to wind uplift specialist fixings suppliers should be consulted for advice. The support battens are then overlaid with the appropriate support structure to the Onduline sheets in accordance with the Onduline roof renovation fixing guide leaflet.
Warm roof over sheeting

Roof preparation: A thorough inspection of the existing roof structure should be undertaken and any deterioration should be rectified, the structure checked as to its suitability for Oversheeting procedures. A review of the original roof design should also be made to check that sufficient ventilation and insulation is provided and if any necessary alterations are required in the roof refurbishment to upgrade the roof design and performance.

Onduline support battens are fixed to existing roof structure

Support purlins are then fixed to roof structure

Note: The Onduline roof renovation leaflet should be consulted for detailed fixing specifications, technical advice should be sought to detail your specific project.

The Ondutile system

Warm roof over sheeting specification Insulation is recommended and should always be used on steel roofs to avoid the risk of heat transfer into the building. To reduce the risk of condensation, it is essential that insulation products are laid in accordance with the manufacturer's instructions. They should include an effective water vapour barrier laid beneath the insulation. If high levels of moisture is present within the building, mechanical vapour extraction should also be provided.

The Ondutile under tile roofing system Only Onduline Classic grade sheets are suitable for use with the market leading Ondutile tile and slate underlay roofing system. This unique system allows tiles to be safely used below the manufacturers minimum recommended roof pitch and benefits from system BBA certification. Note: The Ondutile leaflet should be consulted for detailed fixing specifications.
Return to Contents

Note: The information in this brochure is correct at the time publishing, Onduline reserve the right to change specifications at any time without prior notice. Production team: Tony & Kev Knell, Claire Hayzer, Ian McDonald, Bob & Richard Gibson, Hollie Walker, Video: FACT Liverpool - VERSION 01.01- 2016

Other Instructional leaflets
Onduvilla tiles
Onduvilla tile strips are produced with a unique three tone colour in an attractive `bold roll' tile profile. This recreates the warm natural colours that are normally only associated with expensive and heavy clay roof finishes. Onduvilla is produced in an easy to handle and fix tile strip format, making them the ideal roof covering for a wide range timber framed garden and commercial buildings.
Bardoline shingles
Bardoline tile strip shingles enhance both the style, durability and roof performance of housing, domestic and commercial building projects. Its lightweight, ease of use and fixing allied to its proven versatility make Bardoline the natural choice for a wide range of building projects.

®
www.onduline.co.uk

OnduLINE MINI 18 SHEETS
Onduline Mini 18 sheets are designed with a low profile corrugation which compliments perfectly the scale of sheds, summer houses, workshops and garages. Making Mini 18 the ideal `Do it Once' upgrade to your garden and timber frame buildings. Mini profile sheets are also the only approved sheet for use with the Ondutile `low line' tile underlay system.

Maintenance
To ensure a long service life for your shingles the roof should be cleaned regularly of leaves and debris, as leaf mould can reduce the service life of the product. Also check that tree and shrub overhanging branches are not into contact with the surface of the roof; as wind generated movement can cause surface damage.
Terms and Conditions
Although the colouring process in the manufacture of the Onduline products are long lasting, as with similar natural roofing materials it is subject to the effects of weathering over its lifetime. The colour can also differ between production batches.

Copyright © 2016 All rights reserved. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, including photocopying, recording, or other electronic or mechanical methods, without the prior written permission of Onduline Building Products Ltd.

BBA BRITISH BOARD OF AGREMENT
CERTIFICATE NO. 87 / 1823

www.onduline.co.uk
Onduline Building Products Ltd Eardley House, 182-184 Campden Hill Road, Kensington, London, W8 7AS Tel: 020 7727 0533 Fax: 020 7792 1390 E-mail: enquiries@onduline.net
Return to Contents