Crestron Electronics ZUMKPBATT Two-Way RF Transceiver User Manual ZUMMESH KPBATT IG 7865B Preliminary 0 CS
Crestron Electronics Inc Two-Way RF Transceiver ZUMMESH KPBATT IG 7865B Preliminary 0 CS
User Manual
Pre ZUMMESH-KPBATT Zūm™ Battery-Powered Wireless Keypad Installation Guide The Crestron ZUMMESH-KPBATT is an extremely slim battery-powered Zūm™ wireless keypad with flexible installation. The ZUMMESH-KPBATT is a versatile and easy-to-use addition to the Zūm commercial lighting system. Powered by a battery and slim enough to mount to the surface of a wall, the keypad’s streamlined design and out-of-the-box functionality make it ideal for new or retrofit installations. Zūm keypads are preprogrammed. Install a keypad in a room with a Zūm J-Box Zone Controller (sold separately), perform a series of button taps, and then use the keypad to control the lights in the room – no programming required! Battery-powered Zūm keypads are designed in the following four configurations: • Single-Rocker Switch – Simple on and off lighting control • Four-Button Keypad – Two buttons for on and off control and two scene recall buttons • Six-Button Keypad – Two buttons for on and off control, two buttons for dimming up and dimming down, and two scene recall buttons • Six-Button Keypad with Sensor Control - Two buttons for on and off control, two buttons for dimming up and dimming down, one button for scene recall, and one button for disabling the sensors in the room A basic single-room Zūm system consists of Zūm mesh devices, i.e., dimmers, switches, keypads, and sensors. The Zūm mesh devices in the room communicate directly with each other without the need for a centralized gateway or processor. To monitor or control the room from a centralized Crestron control system, use the ZUMMESH-NETBRIDGE. ® NOTE: The ZUMMESH-NETBRIDGE requires a J-box device to provide power. For quick network setup, use the Zūm app on a smartphone or tablet. SPECIFICATION Power Requirements Enclosure 3. Ensure that the keypad is vertical, and press it against the wall. Press firmly to ensure that the keypad is properly secured to the wall. Additional Resources Description DETAILS CR2032 coin cell battery (included); Provides at least 5 years of battery life 1-gang mountable; Requires decorator-style faceplate (sold separately) Environmental Temperature 30° to 104 °F (0° to 40 °C) Humidity 10% to 90% RH (noncondensing) Dimensions Height 4.25 in (108 mm) Width 1.77 in (45 mm) Depth 0.39 in (10 mm) Visit the product page on the Crestron website (www.crestron.com) for additional information. Use a QR reader application on your mobile device to scan the QR image. Installation Crestron offers several ZUMMESH-KPBATT units.The ZUMMESH-KPBATT’s functionality is based upon its button layout. By default, they control all loads in the room. If linked to a dimmer, the ZUMMESH-KPBATT controls only its linked loads. lim ZUMMESH-KP10ABATT Button Functions Top Button Press: Recalls Scene 1 Hold: Raises lights • Codes: Install in accordance with all local and national electrical codes. • Temperature: For use where temperatures are between 32° to 104 °F (0° to 40 °C). • Electrical Boxes: Several devices can be installed in one electrical box (multigang). For a smooth appearance, install one-piece multigang faceplates (not supplied). Mount the ZUMMESH-KPBATT to a single-gang box or directly to a flat surface using double-sided tape. Two screws are supplied for mounting the keypad to a back box. ZUMMESH-KP10BBATT Button Functions ina ry ON Battery SCENE 2 Prior to operation, remove the battery tab to turn on the keypad. Double-Sided Tape Mounting Secure the ZUMMESH-KPBATT to a flat, clean surface using the supplied double-sided tape. 1. Clean the mounting surface with a light cleaning agent that does not leave a residue. 2. Remove the backing of one piece of the double-sided tape and apply it to the back of the keypad. Repeat for the other piece of double-sided tape. Bottom Button Press: Turns lights off Hold: Lowers lights Press firmly to ensure proper adhesion. NOTES: Observe the following points. Single-Gang Box Mounting Secure the ZUMMESH-KPBATT to a single-gang box using the two supplied screws. Attach a decorator-style faceplate (not supplied). Default Button Functions SCENE 3 OFF On Press: Recalls Scene 1 Hold: Raises lights SCENE 2 Press: Recalls Scene 2 Hold 5 Seconds: Saves Scene 2 SCENE 3 Press: Recalls Scene 3 Hold 5 Seconds: Saves Scene 3 OFF Press: Turns lights off Hold: Lowers lights Remove the battery tab prior to operation. ZUMMESH-KP10CBATT Button Functions ON Battery Replacement To remove the battery, insert a pin or paper clip into the slot on the left side of the keypad. The battery slides out of the opposite side of the keypad. SCENE 2 SCENE 3 OFF On Press: Recalls Scene 1 Hold: No action SCENE 2 Press: Recalls Scene 2 Hold 5 Seconds: Saves Scene 2 SCENE 3 Press: Recalls Scene 3 Hold 5 Seconds: Saves Scene 3 OFF Press: Turns lights off Hold: Lowers lights To remove the battery, insert a pin or paper clip into the hole on the side. Two pieces of tape are supplied to mount the keypad without a backbox. Hold: Lowers lights ZUMMESH-KP10DBATT Button Functions NOTE: The battery must be inserted properly. NOTE: The keypad will not operate if the battery is inserted incorrectly. To install a new battery, insert the battery into the battery slot. The — terminal faces away from the wall. ON SCENE 2 SENSOR DISABLE OFF Battery CR2032 (—) towards the front of the keypad Hold: Raises lights On Press: Recalls Scene 1 Hold: No action SCENE 2 Press: Recalls Scene 2 Hold 5 Seconds: Saves Scene 2 SENSOR DISABLE Press: Recalls Scene 3 Hold 5 Seconds: Saves Scene 3 OFF Press: Turns lights off Hold: Lowers lights Hold: Raises lights Hold: Lowers lights Pre Basic Room Setup Step 1b – Expanding an Existing Single-Room Zūm System A basic single-room Zūm system consists of Zūm mesh devices, i.e., dimmers, switches, keypads, and sensors. The Zūm mesh devices in the room communicate directly with each other without the need for a centralized gateway or processor. To set up a new single-room Zūm system, do the following: Step 1a: Create a new single-room Zūm system. Step 2: Add Zūm mesh devices to the room. Step 3: Finish creating the single-room Zūm system. To modify an existing Zūm system, do the following: Step 1b: Place the system in Joining mode. Step 2: Add Zūm mesh devices to the room. Step 3: Finish creating the single-room Zūm system. To allow other devices to join the room, place the single-room Zūm system into Joining mode. Joining mode can be enabled from any ac-powered device or battery keypad that is already part of the room. 5s NOTE: The device that is used to create the room is automatically added to the room. The device does not need to be added to the room. NOTE: A room can be created only from an ac-powered device. SETUP TEST TEST lim Creating Scenes SETUP TEST Pressing any button on a device that is part of the network takes the system out of joining mode. Joining mode ends automatically after 4 minutes. Adding Zūm mesh devices to a room is quick and easy. Add devices to the room when the room is in Joining mode. Joining mode is automatically enabled after a single-room Zūm system is started (see Step 1a). Joining mode can also be enabled manually (see Step 1b). The LEDs on all ac-powered devices in the system blink when the system is in Joining mode. 2s or 10s NOTE: A Zūm mesh device can belong to only one room. NOTE: The Zūm mesh device used to create the room is already part of the network. It does not need to be added to the network. To add a keypad to the room, press the top button 3 times, and then press and hold the top button for 2 seconds. If the device is not factory fresh, hold the button for 10 seconds. Release the button when the LED lights. The LED blinks slowly to indicate that it is part of the room and that the room is still in Joining Mode. SETUP TEST 2s or 10s 2s or 10s Setting the scenes alters the default presets to allow customization of the brightness levels when a button is pressed. Set scenes using the End-User Method, Manual Method, or the Remote Method. NOTE: Only load controllers bound to this keypad can be in the keypad’s scenes. NOTE: All load controllers bound to this keypad must be in this keypad’s scenes. Step 2 - Adding Zūm Mesh Devices to the Room Start a Single-Room System with a J-Box Device Press the SETUP button 5 times, and then press and hold the SETUP button for 2 seconds. If the device is not factory fresh, hold the button for 10 seconds. Release the button when the LED lights. The LED illuminates for 3 seconds and then slowly flashes to indicate that the room is in Joining mode and that other devices can join the room. Remote Method Use the Remote Method when load controllers are not physically accessible. To customize presets, do the following: 1. Using the keypad in the room, hold the top and bottom buttons simultaneously for 5 seconds until the LED flashes. Then press the top button 2 times, and then the bottom button once. SETUP Expand a Single-Room Zūm System Using a J-Box Device To enter Joining mode, tap the SETUP button 2 times, and then tap the TEST button. NOTE: This can be performed on only one device in the room. Start a New Single-Room System with a Keypad, Dimmer, or Switch Press the bottom button 5 times, and then press and hold the bottom button for 2 seconds. If the device is not factory fresh, hold the button for 10 seconds. Release the button when the LED lights. The LED illuminates for 3 seconds and then slowly flashes to indicate that the room is in Joining mode and that other devices can join the room. Press any button on a device that has already joined the network to end the setup process (e.g., the top button of a keypad or the SETUP button of a J-box device that is blinking its LED). Expand a Single-Room Zūm System Using a Keypad To enter Joining mode, press and hold both the top and bottom buttons for 5 seconds, wait for the LED to light, and then tap the top button once, and then the bottom button once. Step 1a – Creating a Single-Room Zūm System To create a new single-room Zūm system, first form a new room. Step 3 - Finishing the Single-Room Zūm System While the device searches for a network to join, the LED flashes fast. When the device successfully joins a network, the LED lights for 3 seconds. After joining the room, the LED turns off. Unlike the LED on ac-powered devices, the LED on battery-powered devices does not slow blink to show that it has joined the network. End-User Method The end-user method allows fast and efficient setting of the presets. The end-user method is only applicable to SCENE 2 and SCENE 3. It cannot be used on 2-button keypads, and cannot be used to save the ON (scene 1 preset) scene. To customize presets, do the following: 1. Go to each load controller that is bound to the keypad and set the loads to the desired brightness level for the scene. 2. Hold the SCENE 2 or SCENE 3 button for 5 seconds to save the current light levels to the pressed button. 5s 3. Hold the bottom button for 3 seconds until one of the loads in the room begins to flash. The load that is flashing is the "Selected" load. 4. Tap the bottom button to cycle through the loads until the desired load flashes. The load flashes twice and then returns to its previous light level to indicate that it is selected. 5. Adjust the brightness by holding the top button on the keypad to raise the light level or holding the bottom button to lower the light level. 6. To save the light level to a scene, press the ON, SCENE 2, or SCENE 3 button. 7. Press the bottom button to select the next load controller that is bound to this keypad. The load flashes twice and then returns to its previous light level to indicate that it is selected. 8. Repeat steps 4 through 6 for additional load controllers until all load controllers and all scenes are defined. 9. Tap the bottom button 3 times to exit. ina ry Manual Method Use the Manual Method when each load controller is physically accessible. To customize presets, do the following: 1. Using the keypad in the room, hold the top and bottom buttons simultaneously for 5 seconds until the LED flashes. Then press the top button 2 times, and then the bottom button once. • The keypad blinks its LED 2 times every 2 seconds. • Load controllers that are linked with the keypad fast blink their LED. 5s Factory Reset Press any button on a device that has already joined the network to end the setup process (e.g., the top button of a keypad or the SETUP button of a J-box device that is blinking its LED). NOTE: New-in-box devices do not need to be factory reset before joining a system. To factory reset a keypad, press and hold the top and bottom buttons for 5 seconds until the LED lights, and then release both buttons. Then, press and hold the bottom button for 10 seconds until the LED lights. 5s 10s 2. Adjust the load levels. • Using the dimmers, adjust all load levels in the room by pressing and holding the top button to raise the light level or the bottom button to lower the light level. • Using the switches, turn the loads on or off by pressing the top button to turn the load on or the bottom button to turn the load off. • Using the load controllers, press and hold the TEST button on the J-box device to cycle-dim the load. 3. Using the keypad in the room, press the ON, SCENE 2, or SCENE 3 button that should recall the current levels. This saves the levels to the scene. ON SCENE 2 SCENE 3 OFF 4. Repeat steps 2 and 3 for all scenes. 5. Tap the bottom button on the keypad 3 times to exit scene setting. This product is Listed to applicable UL® Standards and requirements tested by Underwriters Laboratories Inc. Ce produit est homologué selon les normes et les exigences UL applicables par Underwriters Laboratories Inc. protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Federal Communications Commission (FCC) Compliance Statement • Reorient or relocate the receiving antenna. This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions:(1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment. • Consult the dealer or an experienced radio/TV technician for help. The product warranty can be found at www.crestron.com/warranty. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable Industry Canada (IC) Compliance Statement CAN ICES-3(B)/NMB-3(B) The specific patents that cover Crestron products are listed at patents.crestron.com. Certain Crestron products contain open source software. For specific information, please visit www.crestron.com/opensource. Crestron, the Crestron logo, and Zūm are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. This document was written by the Technical Publications department at Crestron. ©2017 Crestron Electronics, Inc. Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Installation Guide - DOC. 7865B (2047761) 11.17 Specifications subject to change without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2017:11:03 13:47:02-04:00 Creator : Adobe Illustrator CC 2015.3 (Windows) Modify Date : 2017:11:03 13:47:11-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Title : ZUMMESH-KPBATT_IG_7865B_Preliminary_0_CS Metadata Date : 2017:11:03 13:47:11-04:00 Creator Tool : Adobe Illustrator CC 2015.3 (Windows) Thumbnail Width : 256 Thumbnail Height : 200 Thumbnail Format : JPEG Thumbnail Image : (Binary data 9723 bytes, use -b option to extract) Instance ID : uuid:4324d37c-e1d8-4340-9c0c-01a2c7ab26e8 Document ID : xmp.did:b30ad74c-0e23-1e43-b574-fb8a33625b05 Original Document ID : uuid:5D20892493BFDB11914A8590D31508C8 Rendition Class : proof:pdf Derived From Instance ID : uuid:24a80715-12f9-426c-a89d-be4f757215ca Derived From Document ID : xmp.did:f578a98e-3924-784f-b842-6678d483c6f0 Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8 Derived From Rendition Class : proof:pdf History Action : saved, saved History Instance ID : xmp.iid:5D2E25593251E111B01C938CD82A7350, xmp.iid:b30ad74c-0e23-1e43-b574-fb8a33625b05 History When : 2012:02:06 21:20:48-05:00, 2017:11:03 13:46:55-04:00 History Software Agent : Adobe Illustrator CS5.1, Adobe Illustrator CC 2015.3 (Windows) History Changed : /, / Manifest Link Form : EmbedByReference Manifest Reference File Path : C:\Users\csantimauro\Documents\Chris S\Tasks\ZUMMESH-KPBATT_IG_7865B\DOCS\barcode (31).png Manifest Reference Document ID : 0 Manifest Reference Instance ID : 0 Ingredients File Path : C:\Users\csantimauro\Documents\Chris S\Tasks\ZUMMESH-KPBATT_IG_7865B\DOCS\barcode (31).png Ingredients Document ID : 0 Ingredients Instance ID : 0 Startup Profile : Print Has Visible Overprint : False Has Visible Transparency : False N Pages : 1 Max Page Size W : 17.000000 Max Page Size H : 11.000000 Max Page Size Unit : Inches Font Name : ArialMT, Arial-BoldItalicMT, Arial-BoldMT, Arial-ItalicMT, HelveticaNeueLTStd-BdCn, HelveticaNeueLTStd-Bd, HelveticaNeueLTStd-LtIt, HelveticaNeueLTStd-Roman, HelveticaNeueLTStd-Hv, HelveticaNeueLTStd-Md, MyriadPro-Regular, TimesNewRomanPSMT Font Family : Arial, Arial, Arial, Arial, Helvetica Neue LT Std, Helvetica Neue LT Std, Helvetica Neue LT Std, Helvetica Neue LT Std, Helvetica Neue LT Std, Helvetica Neue LT Std, Myriad Pro, Times New Roman Font Face : Regular, Bold Italic, Bold, Italic, 77 Bold Condensed, 75 Bold, 46 Light Italic, 55 Roman, 85 Heavy, 65 Medium, Regular, Regular Font Type : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type Font Version : Version 5.22, Version 6.90, Version 5.08, Version 6.90, Version 2.035;PS 002.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.035;PS 002.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.035;PS 002.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 1.047;PS 001.103;Core 1.0.38;makeotf.lib1.6.5960, Version 2.035;PS 002.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.035;PS 002.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.106;PS 2.000;hotconv 1.0.70;makeotf.lib2.5.58329, Version 5.22 Font Composite : False, False, False, False, False, False, False, False, False, False, False, False Font File Name : arial_2.ttf, arialbi.ttf, arialbd_0.ttf, ariali.ttf, HelveticaNeueLTStd-BdCn_4.otf, HelveticaNeueLTStd-Bd_5.otf, HelveticaNeueLTStd-LtIt_3.otf, HelveticaNeueLTStd-Roman_2.otf, HelveticaNeueLTStd-Hv_2.otf, HelveticaNeueLTStd-Md_2.otf, MyriadPro-Regular_1.otf, times_1.ttf Plate Names : Cyan, Magenta, Yellow, Black Swatch Group Name : Default Swatch Group, Grays, Brights Swatch Group Type : 0, 1, 1 Swatch Colorant Swatch Name : White, Black, CMYK Red, CMYK Yellow, CMYK Green, CMYK Cyan, CMYK Blue, CMYK Magenta, C=15 M=100 Y=90 K=10, C=0 M=90 Y=85 K=0, C=0 M=80 Y=95 K=0, C=0 M=50 Y=100 K=0, C=0 M=35 Y=85 K=0, C=5 M=0 Y=90 K=0, C=20 M=0 Y=100 K=0, C=50 M=0 Y=100 K=0, C=75 M=0 Y=100 K=0, C=85 M=10 Y=100 K=10, C=90 M=30 Y=95 K=30, C=75 M=0 Y=75 K=0, C=80 M=10 Y=45 K=0, C=70 M=15 Y=0 K=0, C=85 M=50 Y=0 K=0, C=100 M=95 Y=5 K=0, C=100 M=100 Y=25 K=25, C=75 M=100 Y=0 K=0, C=50 M=100 Y=0 K=0, C=35 M=100 Y=35 K=10, C=10 M=100 Y=50 K=0, C=0 M=95 Y=20 K=0, C=25 M=25 Y=40 K=0, C=40 M=45 Y=50 K=5, C=50 M=50 Y=60 K=25, C=55 M=60 Y=65 K=40, C=25 M=40 Y=65 K=0, C=30 M=50 Y=75 K=10, C=35 M=60 Y=80 K=25, C=40 M=65 Y=90 K=35, C=40 M=70 Y=100 K=50, C=50 M=70 Y=80 K=70, C=0 M=0 Y=0 K=100, C=0 M=0 Y=0 K=90, C=0 M=0 Y=0 K=80, C=0 M=0 Y=0 K=70, C=0 M=0 Y=0 K=60, C=0 M=0 Y=0 K=50, C=0 M=0 Y=0 K=40, C=0 M=0 Y=0 K=30, C=0 M=0 Y=0 K=20, C=0 M=0 Y=0 K=10, C=0 M=0 Y=0 K=5, C=0 M=100 Y=100 K=0, C=0 M=75 Y=100 K=0, C=0 M=10 Y=95 K=0, C=85 M=10 Y=100 K=0, C=100 M=90 Y=0 K=0, C=60 M=90 Y=0 K=0 Swatch Colorant Mode : CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK Swatch Colorant Type : PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS Swatch Colorant Cyan : 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 100.000000, 100.000000, 0.000000, 15.000000, 0.000000, 0.000000, 0.000000, 0.000000, 5.000000, 20.000000, 50.000000, 75.000000, 85.000000, 90.000000, 75.000000, 80.000000, 70.000000, 85.000000, 100.000000, 100.000000, 75.000000, 50.000000, 35.000000, 10.000000, 0.000000, 25.000000, 40.000000, 50.000000, 55.000000, 25.000000, 30.000000, 35.000000, 40.000000, 40.000000, 50.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 85.000000, 100.000000, 60.000000 Swatch Colorant Magenta : 0.000000, 0.000000, 100.000000, 0.000000, 0.000000, 0.000000, 100.000000, 100.000000, 100.000000, 90.000000, 80.000000, 50.000000, 35.000000, 0.000000, 0.000000, 0.000000, 0.000000, 10.000000, 30.000000, 0.000000, 10.000000, 15.000000, 50.000000, 95.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 95.000000, 25.000000, 45.000000, 50.000000, 60.000000, 40.000000, 50.000000, 60.000000, 65.000000, 70.000000, 70.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 75.000000, 10.000000, 10.000000, 90.000000, 90.000000 Swatch Colorant Yellow : 0.000000, 0.000000, 100.000000, 100.000000, 100.000000, 0.000000, 0.000000, 0.000000, 90.000000, 85.000000, 95.000000, 100.000000, 85.000000, 90.000000, 100.000000, 100.000000, 100.000000, 100.000000, 95.000000, 75.000000, 45.000000, 0.000000, 0.000000, 5.000000, 25.000000, 0.000000, 0.000000, 35.000000, 50.000000, 20.000000, 40.000000, 50.000000, 60.000000, 65.000000, 65.000000, 75.000000, 80.000000, 90.000000, 100.000000, 80.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 100.000000, 95.000000, 100.000000, 0.000000, 0.003100 Swatch Colorant Black : 0.000000, 100.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 10.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 10.000000, 30.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 25.000000, 0.000000, 0.000000, 10.000000, 0.000000, 0.000000, 0.000000, 5.000000, 25.000000, 40.000000, 0.000000, 10.000000, 25.000000, 35.000000, 50.000000, 70.000000, 100.000000, 89.999400, 79.998800, 69.999700, 59.999100, 50.000000, 39.999400, 29.998800, 19.999700, 9.999100, 4.998800, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.003100 Producer : Adobe PDF library 15.00 Page Layout : SinglePage Page Count : 2EXIF Metadata provided by EXIF.tools