 1Technical parameters Input voltage  DC5V ±0.25V Power  425mW(work);500mW(instantaneous) Battery  Charge Time  2.5 Hours Battery  Scan Time  30 Hours Current  25mA(work);95mA(instantaneous) Light  Visible light laser diode, wavelength 650 nm Laser Level   Laser Level II laser safety standards Decoding speed  100 times / sec Scan angle  ±60°,±65°,±42°(about turn) Resolution  0.10mm  (4mil) Ability decode UPC-A,UPC-E,EAN-13,EAN-8,ISBN/ISSN,Code 39 ,int25,ind25,Coda bar,Code 128,Code 93,Code 11,MSI/Plessey,UCC/EAN128…… Prompt manner  Buzzer, LED indicator Communication distance  30m (void) Communication mode  2.4G wireless  Data memory  8K Byte Trigger manual  manual scanning  weight  153g Interface Type       Shell material  ABS+PC External dimension  164*67*95 mm(scanner)  71*24*9.3mm (acceptor) Temperature  0℃ to 45℃(work);-40℃ to 60℃(save) Humidity  5% to 90% Seismic capacity  multiple 1.5 m drops to concrete floor impact Program update  computer online updates Aiming:Note: The scanner performs best when it is not exactly perpendicular to the barcode
 2Simple manual    Wireless setting and Default     Return to default       Wireless barcode scanner pair with the receiver   The scanner must be pair with a receiver then you can transfer the data to your PC or other host. Channel setting   We have paired the scanner with receiver and have a default channel before we product it .And if you want make change the channel for the scanner, please check the follow method .You can also accord to your own needs to set channel, channel range is“ 01-20” Method  :please insert the receiver on your PC ,then in 20seconds you use the scanner decode the “channel setting  01—20” code ,then scanner two numbers between 0-9 (page 4 ) the number code .then you can use the new channel .  Example : you need 06 as the new channel :  pair at first then scan the “Channel setting  01-20” then scan  “0” then scan “6”that all .  Channel setting   01-20
 3Scanner ID setting   You can set the ID from 01-99 any number as the ID . For example ,if you want set the ID as 23 ,please scan the code “Setting ID    01-99” at first then scan the number code “2” and “3”.then you finish the ID setting step.   Setting ID   01-99     Add the ID as Prefix   Please scan the code “Open Identification as Prefix” If you want use the ID as the Prefix, then you will find the ID in the front of the every barcode .     Open Identification as Prefix    Close Identification as Prefix  *
 4Number code 0   1   2   3   4   5   6   7   8   9
 5power sleep time setting    Enter setting sleep time      Please choose the follow power sleep time       20sec  *   30sec   60sec   2min   5min   10min   20min   No sleep
 6Working mode   Normal mode  :Scan barcodes directly then the decoded data transfer to the receiver and    displayed on the PC or your host ,But if    the transmission fails (for example, over the transmission distance or the receiver is not open), then issue a "de de de " sound prompts the user to transmission failure.   Normal mode  *      Inventory mode: When the scanner is not in the receiver’s operating range, please use the Inventory mode  。First you can set the mode “Inventory mode” then you scan the barcode ,the data will be stored in the scanner, In the end of your work, you can scan the “Transfer data “,then the data will be transferred to your PC or other host . You also can check how many data you had decode .please scan the “Total number of data”. After you transfer the data in the Inventory mode ,please scan the “Clear data” then you can do the next work .  Inventory mode     Transfer data    Total number of data   Clear data
 7 Multiscan Functions  Defaults                   Buzzer Mode  Good Read Beep Tone-None               Good Read Beep Tone-Reset  Good Read Beep Duration               Save Mode-Enable    Reading Mode  Single Scan                               Single Scan No Trigger                  Multi Scan              Multi Scan No Trigger  Continuous Scan  Pulse Scan
 8Language USA                     German  France                   Universal         Baud Rate  1200                  2400  4800                       9600*  19200  38400
 9Data Bit 8                                7    Stop Bit 1                               2    Parity Bit  NONE                            ODD  EVEN
 10Code Symbol On/Off  CODE 11 Enable*                 Disable  CODE 128 Enable*                          Disable  CODE 39 Enable*  Disable  FULL ASCII Enable*                 FULL ASCII Disable  CODE 93 Enable*                        Disable  CODABAR Enable*                        Disable
 11Interleaved 2 Of 5 Enable*                                           Disable                     Industrial 2 Of 5 Enable  *                                           Disable                     MSI/PLESSEY Enable*                         Disable  UPC-A Enable*                         Disable  UPC-E Enable*                       Disable  EAN-13 Enable*                        Disable  EAN-8 Enable*                       Disable
 12OTHER I  Expand UPC-E to UPC-A enable             Expand UPC-E to UPC-A Disable  Expand UPC-A to EAN-13 Enable              Expand UPC-A to EAN-13 Disable  Convert EAN-13 to ISBN Enable            Convert EAN-13 to ISBN Disable   Supplement Digits   UPC/EAN Supplements Disable*         UPC/EAN Supplements-2 only              UPC/EAN Supplements-5 only          UPC/EAN Supplements-2&5 only                             CODABAR Send Chars Enable             CODABAR Send Chars Disable  CODE39 Send Chars Enable              CODE39 Send Chars Disable
 13OTHER II    Suffix setting  Termination Char-CR *                    Termination Char-LF  Termination Char-CR+LF                      None   Codes Preamble ‘STX’                    Codes Preamble ‘ETX’    Convert To Uppercase    a→A                 Convert To Lowercase  A→a
                                                                               This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment。  Company: Farsun Photoelectric Science Technologies co., LTD Name: Wireless laser barcode scanner Model Number: FG2106      FCC ID: 2AAS5-FG2106