Nortek Security and Control 00144 Wireless Multi-Function Sensor / Wireless PIR Motion Sensor User Manual 10012103X4M4IN1Z 1 Instructions indd

Nortek Security & Control LLC Wireless Multi-Function Sensor / Wireless PIR Motion Sensor 10012103X4M4IN1Z 1 Instructions indd

Contents

User Manual_M4IN1Z-1

1
GOCONTROL MINI 4IN1
The GoControl family of Z-Wave® certifi ed wireless Lighting Products (smart
LED fi xtures, bulbs, switches, dimmers, outlets and plug-in modules) Control
Products (thermostats, irrigation controller and garage door controller) and
Sensors (fl ood, leak, alert sounder, motion sensor and door/window sensor)
bring a new level of intelligent wireless Home Automation capability to
commercial and residential environments.
The Z-Wave wireless protocol is an international wireless standard for remote
home automation, security and other applications. This product can be included
and operated in any Z-Wave network with other Z-Wave certifi ed devices
from other manufacturers and/or other applications. All non-battery operated
nodes within the network will act as repeaters regardless of vendor to increase
reliability of the network.
The M4IN1Z-1 Smart Multifunction Sensor is simple to set up and combines 4
popular functions in a small battery powered footprint: 360° PIR, Temperature,
Humidity and Light Sensors.
GoControl Z-Wave products are easy to install, are Z-Wave Plus certifi ed, and
allow dealers to create an integrated wireless network with nearly limitless
expansion and interoperability with security, energy management, home
entertainment, appliances, and more
Z-WAVE PLUS FEATURES
The M4IN1Z-1 contains a Z-Wave 500 Series Module that supports Z-Wave
Plus® features. A Z-Wave certifi ed portable or stationary Controller can
communicate with the Z-Wave 500 Series Module. Depending on the capability
of the Controller or gateway software, the following operations can be performed
by Mini 4in1. Refer to the Controller or gateway manual for details.
Send an alert if motion is sensed.
Provide the absolute temperature.
Provide the humidity level.
Send an alert when light is present.
Add or Remove Mini 4in1.
Over-the-air firmware update by the gateway or static Controller.
INSTALLATION
The M4IN1Z-1 can be mounted on a wall or ceiling using the double stick tape
(included). It can also be placed on a table top.
1. Remove the rear cover by pushing button on sensor top.
2. Insert 2 AAA batteries (included). The LED will briefl y illuminate in RED,
BLUE, then GREEN.
3. Replace the rear cover onto the sensor top.
4. Install in permanent location using provided double stick tape. The
M4IN1Z-1 should be mounted (6) six feet from the fl oor.
5. Press the program switch. The Walk Test LED will fl ash 5 times if the sensor
has not been “included” in a Z-Wave network. If the LED fl ashes once, the
sensor has been already been “included”.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,M4IN1Z-1,GO CONTROL; P/N: 10012103 X4; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 11.000”; TOLERANCE ± .125”; SCALE: 1-1
M4IN1Z-1
Wireless Multi-Function Sensor
360° PIR, Temp, Humidity and Light Sensor
NOTE: This unit must be added to the Network only where it will be permanently installed. The proper operation of this node in the
mesh network is dependent on it knowing its location with respect to other nodes. You cannot “test bench” confi gure this unit, then install.
Figure 1. M4IN1Z-1 Mini 4in1 Sensor Components
Figure 2. Removing Rear Cover of Mini 4in1 Sensor
LIGHT SENSOR
PROGRAM SWITCH
REMOVE REAR COVER
SENSOR TOP
PUSH BUTTON
SENSOR TOP
AAA BATTERIES
Figure 3. Install Batteries into Sensor Top
2
Z-WAVE PROGRAMMING
Adding to a Network
Refer to your Controller operating instructions to add this switch under the
command of the Wireless Controller
1. With your Controller in Discovery or Add Mode, press the Program Switch
for 1 (one) second. The Yellow LED will blink. The device will appear in the
list of devices and should display as (4) four items: M4IN1Z-1 (Motion),
Light Sensor, Temperature Sensor and Humidity Sensor.
If the Controller/Gateway shows the addition failed, repeat Steps 1-3.
NOTE: If you have trouble adding the M4IN1Z-1 to a group it may be that
the Home ID and Node ID were not cleared from it after testing. You must
rst “RESET UNIT” to remove it from the network. Although adding it to a
group includes it in the network, removing it from a group does not remove
it from the network. “RESET UNIT” removes it completely from the network.
To Reset Unit (if required):
In the event that your primary Controller is lost or otherwise inoperable, to reset
the M4IN1Z-1 and clear all network information, follow these steps:
1. Remove cover to trigger the tamper switch. The LED will fl ash once and
send out Alarm Report.
2. Press Program Switch 10 times within 10 seconds. The M4IN1Z-1 will send
the “Device Reset Locally Notifi cation” command and reset to the factory
default. (Remark: This is to be used only in the case of primary controller
being inoperable or otherwise unavailable).
3. The M4IN1Z-1 will completely reset to factory defaults.
Removing from a Network:
The M4IN1Z-1 can be removed from the network by the Controller/Gateway.
Refer to the Controller operating instructions for details. Be sure to select the
M4IN1Z-1 (PIR) to remove as the other Sensors are tied to this main device.
1. With your Controller in Remove Mode, press the Program Switch for one
(1) second.
2. You should see an indication on your Controller that the device was removed
from the network.
Association
1. Press the program switch on the M4IN1Z-1 to initiate the “Awake” mode.
The LED will fl ash once.
2. Put your Controller into “Association,” and following its instruction to
associate the M4IN1A-1 to other devices.
Other Z-Wave Commands
Auto Wake Up:
Use “Wake Up” command to set up the awaking time (from 10 minutes to 1
week) and send the wake up notifi cation to the controller.
Battery Capacity Detection:
Use “Battery Get” command to have the battery capacity back in %.
It will detect the battery capacity automatically.
Low Battery Auto Report when power is lower than 2.6V +/-0.1V.
Temperature:
If the present temperature is different than previously recorded and has
changed by more than the value in Parameter 2 (see below), the sensor will
report the present temperature to the hub. The LED will fl ash every (3) three
minutes to represent the temperature.
Temperature LED Color
Under 59°F Green
60 - 73° F Blue
74 - 82° F Yellow / Yellow
Green
83 - 97° F Purple
Over 97° F Red
Multilevel Sensor Report
Sensor Type 0x01
Scale 0x00 (°C)
0x01 (°F)
Size and Precision 2
Humidity Report:
If the present humidity is different than previously recorded and has changed
by more than the value in Parameter 3(see below), the sensor will report the
present illumination.
Light Report:
If the present illumination is different than previously recorded and has changed
by more than the value in Parameter 4 (see below), the sensor will report the
present illumination.
Multilevel Sensor Report
Sensor Type 0x03
Scale 0x00
(%)
Size and Precision 2
OPERATION
When a person walks in from of M4IN1Z-1, the sensor will send Basic set
On (0xFF) and the Red LED will flash once. Refer to status report as table
below.
In no movement is detected in (3) three minutes (default), it will send Basic
Set OFF (0x00) will be sent and the Red LED will flash once.
The M4IN1Z-1 is equipped with tamper switch. If the tamper switch is
triggered ( or the cover is removed), the M4IN1Z-1 will send an Alarm
Report.
If the tamper switch is closed (or the cover closed), the M4IN1Z-1 will send
an Alarm Report.
• Supports OTA Firmware update from the controller. Please refer to your
controller manual and use COMMAND_CLASS_FIRMWARE_UPDATE_
MD_V2. To proceed with the OTA process. Once the OTA function is
successful, make sure to exclude the device and include again before using
the device.
Figure 4.Detecting Area
9M
TOP VIEW SIDE VIEW
CEILING
DETECTING AREA: UNIT: METER
0
1
2
3
456 123456M
0M
5M
3
Alarm V1
Movement &
Tamper Switch
Notifi cation V4
(Movement)
Notifi cation V4
(Tamper Switch)
Alarm Type 0x07
Alarm Level 0x00 (No
movement after
3 min.) 0xFF
(Motion detected)
Notifi cation Type 0x07 0x07
Notifi cation Event 0x08 (Motion
detected)
0x00 (No
movement after
3 min.)
0x03 (Cover
removed)
0x00 (Cover
closed)
Notifi cation Event
Parameter
0x08 (Motion
detected) 0x00
(No movement
after 3 min.)
0x03
CONFIGURATION
The M4IN1Z-1 supports the Confi guration command. Each unit can be
confi gured to operate slightly differently that how it works when it is fi rst
installed.
Using the Confi guration command , the following can be confi gured:
Temperature
The reporting temperature parameters can be set to the consumer’s specifi c
needs, changing from Celsius (default) to FaHrenheit and the reporting
threshold (default 1° C)
Parameter Size Value Default
11 bit 0°C 0x00 °C (0x00)
Parameter °F 0x01
21 bit 1 - 50 (Setup from
0.1° C - 5° C
1 (1°C)
Humidity
Parameter Size Value Default
31 bit 1 - 50 (Setup from
1% - 50%)
10%
Light
Parameter Size Value Default
41 bit 0.5 - 50 (Setup
from 0 for OFF or
5% - 50%)
10%
Motion Sensor
Parameter Size Value
51 bit 1 - 255 (unsigned
decimal) Minutes
(default: 3 minutes)
Parameter Size Value
61 bit 1 - 7
(default: 4)
(Parameter 5) Re-trigger duration: User can change value from 1 to 255
minutes to setup the re-trigger time when there is no movement detected in the
period of time. Default is 3 minutes.
(Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1=
most sensitive, 7 = most insensitive, default values = 4.
LED Mode
Parameter Size Value
71 bit 1 - 3 (Mode 1 - Mode 3)
Mode 1LED Turn Off
(Both Temp / PIR Trigger)
Mode 2 (Breathing
Light Mode) PIR (Quick
Flash)
Mode 3 LED Quick
Flash (Temp / PIR Trigger)
SPECIFICATIONS
Power: 2 - AAA battery (Included)
Signal (Frequency): 908.42 MHz / 916 MHz
Range: Up to 130 feet line of sight
Z-WAVE COMMAND CLASSES
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
REGULATORY INFORMATION
The M4IN1Z-1is certifi ed to comply with applicable FCC and IC rules and
regulations governing RF and EMI emissions.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including
interference that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions may cause
harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
Consult the dealer or an experienced radio/TV technician to help.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment
4
Copyright © 2016 Nortek Security & Control LLC 10012103X4
IC Notice
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme NMB-003
du Canada. Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est autorisée
aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.
This device complies with the Industry Canada license exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
NOTICES
Z-Wave® and Z-Wave Plus® are registered trademarks of Sigma Designs and
its subsidiaries in the United States and other countries.
WARRANTY
What is Covered?
Nortek Security & Control (“NS&C”) warrants to consumers who
purchase this product for personal, family or household purposes
new from NS&C directly or from an authorized NS&C dealer, that the
product will be free from defects in materials and workmanship for a
period of (1) year from the date of purchase. This warranty only applies
if the product is installed at a residence in the 50 United States or
District of Columbia, and only at the site of the original installation. It is
not transferable. This warranty is not extended to resellers.
If a defect exists, NS&C will have you ship the defective part or product
to us and we will, at our option, either repair or replace it. This warranty
does not cover the cost of labor to remove a defective part or product
or to reinstall any repaired or replacement part.
This warranty does not cover defects or damages caused by improper
handling, maintenance, storage, installation, removal or re-installation,
misuse, non-factory authorized modifi cation or alteration, use of
incompatible accessories, electrical power problems or surges, impact
by foreign objects, accident, fi re, acts of God, normal wear and tear
or shipping damage other than a shipment from NS&C. Note that all
NS&C products are designed to be installed, removed and serviced by
trained individuals or professionals.
Keep your original sales receipt as it will be required to obtain warranty
service.
This warranty shall not be extended or restarted upon receipt of any
repaired or replacement part or product under this warranty. No person
is authorized to extend or otherwise modify this warranty.
How do I Obtain Warranty Service?
To obtain warranty service, email our Returns Department at returns@nortek.
com. Include your name, address, telephone number, the model number of
your product, a copy of your original sales receipt, and a description of the
problem. Unless we need to discuss the situation further with you, you will be
emailed a Return Authorization Number and shipping instructions. If we need
to discuss the situation further with you, we will call or email you. NS&C may
require troubleshooting on installed product before a Return Authorization
Number is issued. Anything shipped to us without a Return Authorization
Number will be automatically returned unopened. You are responsible for the
charges for shipment to us, unless you are a California resident
Limitations
THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED
HEREIN.
Some states do not allow limitations on how long an implied warranty lasts, so
the above limitation may not apply to you.
NS&C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING FROM THE BREACH OF ANY WRITTEN OR
IMPLIED WARRANTY.
Some states do not allow the exclusion of limitation or consequential damages,
so the above limitation or exclusion may not apply to you.
This warranty gives you specifi c legal rights, and you may also have other legal
rights which vary from State to State.
Important !!!
Radio controls provide a reliable communications link and fi ll an important
need in portable wireless signaling.
However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC
Rules and Regulations as Part 15 devices.
As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time
and may be blocked by radio signals that occur on or near their operating
frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against
undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior
to acting as a wholesale distributor or dealer, and these facts should be
communicated to the ultimate users

Navigation menu