Visonic SD304CPG2 SHOCK DETECTOR User Manual D 304286 SD 304 PG2 Installation Instructions
Visonic Ltd. SHOCK DETECTOR D 304286 SD 304 PG2 Installation Instructions
Visonic >
User Manual
SDSD-304 PG2 PowerG, Wireless Shock and Contact detector with Wired Input Installation Instructions 1. INTRODUCTION The SD-304 PG2 is a wireless PowerG innovative shock detector with optional magnetic contact and auxiliary input interfacing with PowerMaster-10 and PowerMaster-30 control panels (version 16 and higher). The SD304 PG2 fits windows, doors, walls or roofs and is ideal for residential or commercial installations. It detects and analyzes gross attacks or a series of low level shocks (up to 10 low level shocks within 30 seconds) and provides early warning of any attempt of intrusion before a burglar actually breaks-in. The detector incorporates: • A shock / vibration piezoelectric sensor. • Optional reed switch with anti-masking sensor to prevent attempts of magnetic masking of the reed switch. • Optional auxiliary input for connecting other devices Installer added-value features: • Digital display enables fast and easy shock level adjustment • Full remote configuration from PowerMaster control panel or Monitoring Station saves the need to physically access the shock detector for configuration • Remote view of: Low Battery, front and back Tamper, Supervision • An LED lights whenever alarm or tamper events are reported (the LED does not light while a supervision message is being transmitted). A. Transmission LED B. Magnet Figure 1: External View 2. INSTALLATION 2.1 Mounting A. Auxiliary input terminals B. Back tamper switch (behind P.C. board) C. Battery clips D. Break-away segment (for back tamper) E. Digital display F. Front tamper switch G. Enroll button H. LEDs indication I. Reed switch J. Up and down buttons Figure 2. Base with P.C. Board Removed Refer to the Shock Detection Radius, in the Specifications section, according to the surface material used. Install the device in a location where a strong shock impact is expected. The unit should be mounted on a flat surface and firmly fixed using both mounting screws. For magnetic contact detection, it is highly recommended to attach the detector to the door/window on the fixed frame and the magnet to the movable part (door or window). Make sure that the magnet is located not more than 6 mm (0.25 in.) from the detector’s marked side. Note: Once the cover is removed, a tamper message is transmitted to the control panel. Subsequent removal of the battery prevents transmission of "TAMPER RESTORE", leaving the detector in permanent alert. To avoid this, press the tamper switch while you remove the battery. Caution! Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to manufacturer's instructions. Attention! The unit has a back tamper switch (optional) under the PCB. As long as the PCB is seated firmly within the base, the switch lever will be pressed against a special break-away base segment that is loosely connected to the base (Figure 2). Be sure to fasten the break-away segment to the wall. If the detector unit is forcibly removed from the wall, this segment will break away from the base, causing the tamper switch to open. D-304286 SD-304 PG2 Installation Instructions 1. Insert a flat-edged screwdriver into the slot and push upward to remove cover. 2. Remove screw. 3. Separate base from cover. 4. Secure the base to the mounting surface using the two screws. CAUTION! Do not use double-sided tape, as this will tend to insulate the detector from vibrations. 5. Insert the battery while observing polarity. 6. Mount the magnet near its location mark with 2 screws. A. Fixed frame B. Moving part Note: 868 MHz device is illustrated in the example. The same mounting procedure should be performed for 433 MHz and 915 MHz devices. * This additional screw is used for back tamper only. Figure 3. Mounting 2.2 Auxiliary Input Wiring (Fig. 4) A. Connect the auxiliary sensor contacts across the SD-304 PG2 auxiliary input terminals. Note: Maximal guaranteed cable length is 10m. B. If the auxiliary input of the SD-304 PG2 is defined as a Normally Closed (N.C.) type, series connected N.C. sensor contacts must be used exclusively. An alarm message is transmitted once the loop is opened. C. If the auxiliary input of the SD-304 PG2 is defined as a Normally Open (N.O.) type, parallel connected N.O. sensor contacts must be used exclusively. An alarm message is transmitted once the loop is closed. D. For End of Line (EOL) supervision: Normally Closed (N.C.) or Normally Open (N.O.) sensor contacts can be used, as shown in Figure 4. A 2.2kΩ E.O.L. resistor must be wired at the far end of the zone loop. An alarm message is transmitted once the loop is opened or short circuited. E. For Double End of Line (DEOL) supervision: Two Normally Closed (N.C.) sensor contacts can be used, as shown in Figure 4. Two 2.2kΩ E.O.L. resistors must be wired at the far end of the zone loop which is opened or short circuited. Events messages are transmitted according to ALM/TAMP contacts status. 2.3 Enrollment Figure 4. AUX Input Wiring Examples Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu. A general description of the procedure is provided in the following flow chart. Step 1 Step 2 Enter the Installer menu and select “02:ZONES/DEVICES” 02.ZONES/DEVICES Step 3 Enroll the detector: press the enroll button and then release it as soon as the yellow LED lights, or, enter the device ID (on the back of device) Select "ADD NEW DEVICE" See Note 1 ADD NEW DEVICES ENROLL NOW or ENTR ID:XXX-XXXX Step 4 Select the desired Detector Number for the new device Z02:Shk+AX+CntG3 ID No. 170-XXXX MODIFY DEVICES Step 5 Step 6 Configure Location and Zone Type Parameters Z02.LOCATION Z02.ZONE TYPE Enter PARTITIONS. See Note 2 Z02:PARTITIONS Step 8 Step 7 Assign partitions by pressing the and buttons Z02:P1 P2 P3 Select "Device Settings" and see below to configure the (AUX) button. Z02:DEV SETTINGS means scroll and select D-304286 SD-304 PG2 Installation Instructions Notes: 1. If the shock detector is already enrolled, you can configure the device parameters and assign partitions via the “Modify Devices” option – see Step 2. 2. PARTITIONS will appear only if PARTITIONING was previously enabled in the panel. 2.4 Configuring the Magnetic Contact Device Parameters Enter the table. DEVICE SETTINGS menu and follow the configuration instructions for the SD-304 PG2 shock detector as described in the following Option Alarm LED Configuration Instructions Determine whether or not the alarm LED indication will be activated. Optional settings: ON (default) or OFF. • Reed Switch Determine whether to enable or disable the internal reed switch. Optional settings: Enabled or Disabled (default). Magnetic AM Define whether to enable or disable the detection of magnetic tampering. Note: The selected option of this menu is functional only if the Reed Swtich menu was previously set to "Enabled". Optional settings: Enabled or Disabled (default). AUX input Define the external input according to the installer's requirements. Optional settings: Disabled (default), End of Line, Normally open, Normally close or Double EOL. • Sens. Threshold Define the sensitivity threshold of the shock detector when configuring from the panel. Optional settings: Sens. Thresh. 1 to Sens. Thresh. 19 (default setting is Sens. Thresh. 8). Note: Configuration of this feature can be performed either from the panel or from the device on condition that the device was already enrolled and there is synchronization between the panel and device. If an “E” appears on the device’s digital display, this indicates no synchronization. Accumulated Define whether Accumulation mode, when configuring from the panel, is Enabled or Disabled. Optional settings: Enabled or Disabled (default). 2.5 Local Operating and Calibrating of the Shock Detector The SD-304 PG2 can be calibrated locally only when the device is in Local Diagnostics mode (first 15 minutes after opening the cover). When the device is not in this mode, but further calibration is required, the installer should reset the device by closing the tamper switch. 1. Press on the "Up" or "Down" button to turn on the digital display. The letter 'G' appears on the display for 3 seconds to indicate Gross Attack levels (thresholds). Then, the menu appears on the display to enable you to select a number in the range of 1-19. If, instead of a number the letter "E" appears on the display, this indicates that there is no communication link between the unit and control panel and, therefore, local adjustment is not allowed. Note: If no buttons are pressed within 20 seconds, the digital display turns off. 2. Change the threshold by pressing the "Up" or "Down" button. Note: The lower the threshold, the higher the sensitivity, therefore, the lowest thresholds are more suitable for harder materials, such as concrete. 3. While the SD-304 PG2 threshold menu is active, knock on the surface with the required force for the detector to set the required threshold. The power of the detected knock will be presented on the display of the SD-304 PG2 as a blinking number for 3 seconds. The displayed number will be in the range of 1 to 19, where 1 is very weak and 19 is very strong. Note: If the installer knocks on the surface but nothing appears on the display, this indicates that no shock is detected. If a hyphen blinks, this indicates that the knock is above the highest threshold of the detector. 4. Repeat the same test several times. 5. Press the "Up" or "Down" button to navigate to the threshold number to be set and then press the "Up" and "Down" buttons simultaneously to set the threshold. 6. The detector now moves to the next menu, the Accumulated menu (shown as "A" on the display). Press the "Up" or "Down" buttons to Enable ("1" on the display) or Disable ("0" on the display) the Accumulation mode. Press the "Up" or "Down" buttons simultaneously to set the selected option. Note: When Accumulation is enabled, the power of impact will still indicate the strength of a single knock, therefore, it is recommended to disable this parameter while the Threshold is tested and to enable the Accumulation mode only after setting the Threshold. 7. If after the "Up" and "Down" buttons are simultaneously pressed the letter “E” appears, this likely indicates that there is no communication link between the unit and control panel. Check if the panel is properly powered. D-304286 SD-304 PG2 Installation Instructions 3. LOCAL DIAGNOSTICS TEST Before testing, separate the base from the cover (see Figure 3). A. Press the tamper switch once and release it. B. Put back the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front cover to the base with the case closure screw. C. Use a hammer to apply shock in close proximity to the detector and verify the red LED blinks, indicating detection. D. After 2 seconds the LED blinks 3 times. The following table indicates received signal strength indication. LED response Green LED blinks Orange LED blinks Red LED blinks No blinks Reception Strong Good Poor No communication IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the device, re-locate it and re-test until a "good" or "strong" signal strength is received. Note: For detailed Diagnostics Test instructions, refer to the control panel Installer Guide. 4. EVENT EVENT INDICATIONS LED Indications Event Red LED ON 0.2 sec. Tamper open / close Red on 2 sec. Shock Red on 2 sec. Open close door Red on 2 sec. Open close Aux input Yellow LED on AM detection – diagnostic mode Yellow LED blinks slowly (0.2 sec. ON, 30 sec. OFF) AM detection – Normal mode 5. MISCELLANEOUS COMMENTS Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due to low transmitting power and limited range (required by FCC and other regulatory authorities), there are some limitations to be considered: A. Receivers may be blocked by radio signals occurring on or near their operating frequencies, regardless of the digital code used. B. A receiver responds only to one transmitted signal at a time. C. Wireless devices should be tested regularly to determine whether there are sources of interference and to protect against faults. 6. COMPLIANCE WITH STANDARDS Compliance with Standards The SD-304 PG2 is designed to comply with the following standards: Europe: EN 301 489-3, EN 50130-4:( 95) & A1 : (98) & A2: (03), EN 300 220-2, EN 60950-1, EN 50130-5, EN 50131-1, EN 50131-6, EN 50131-2-6: 2008 Grade 3, Class II, EN 50131-2-8. The SD-304 PG2 is compatible with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999. UK: This product is suitable for use in systems installed to conform to PD6662:2010 USA: CFR 47 part 15 (FCC) Canada: RSS 210 This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with the essential requirements and provisions of Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio and telecommunications terminal equipment. The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in the technical brochure. This functionality has not been tested to comply with the respective technical requirements and should therefore be considered outside the scope of the product’s certification. Opening 20mm+/5mm 14mm+/5mm 25mm+/5mm EN 50131-1 Security Grade EN 50131-1 Environmental Class Wood Closing 14mm+/6mm 15mm+/5mm 24mm+/5mm Supports Direction Soft Iron Opening Closing 15mm+/-5mm 14mm+/5mm 15mm+/-5mm 14mm+/5mm 25mm+/-5mm 24mm+/5mm Grade 3 Class II D-304286 SD-304 PG2 Installation Instructions FCC Compliance Statement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: – Re-orient or re-locate the receiving antenna. – Increase the distance between the device and the receiver. – Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician IC statement: This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. WARNING! To comply with FCC and IC RF exposure compliance requirements, the device should be located at a distance of at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter. WARNING! The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could void the user’s FCC or other authority to operate the equipment. The technical documentation as required by the European Conformity Assessment procedure is kept at: UNIT 6 MADINGLEY COURT CHIPPENHAM DRIVE KINGSTON MILTON KEYNES MK10 0BZ. TEL.: +44(0)845 0755800 FAX: +44(0)845 0755801 W.E.E.E. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. Directive 2002/96/EC Waste Electrical and Electronic Equipment. APPENDIX: APPENDIX: SPECIFICATIONS Frequency Band (MHz) Communication Protocol Alarm Input Tamper Supervision Tamper Alert Power Supply Battery type Battery Life Expectancy Shock Detection Radius Operating Temperature Storage Temperature Humidity Auxiliary Input Cable Length Auxiliary Input EOL Resistor Dimensions (LxWxD) Weight (including battery) Europe and rest of world: 433-434, 868-869 USA: 912-919 PowerG One auxiliary Front and back Signaling at 4-min. intervals Reported when a tamper event occurs Type C 3 V Lithium CR-123A type battery, Panasonic, Sanyo or GP only. 5 years (for typical use) with all sensors enabled Window 4m PVC double glass TBD Wood 3.5m Brick/concrete walls 2.5m -10°C to 55°C (14°F to 131°F) -20°C to 60°C (-4°F to 140°F) Average relative humidity of approximate 75% non-condensing. For 30 days per year relative humidity may vary between 85 % and 95 % non-condensing 10m max. 2.2 KΩ 118 x 27 x 30 mm (4-5/8 x 1-1/8 x 1-3/16 in.) 130g (4.6 oz) D-304286 SD-304 PG2 Installation Instructions WARRANTY Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the “Purchaser”) against defective workmanship and materials under normal use of the Product for a period of twelve (12) months from the date of shipment by the Manufacturer. This Warranty is absolutely conditional upon the Product having been properly installed, maintained and operated under conditions of normal use in accordance with the Manufacturers recommended installation and operation instructions. Products which have become defective for any other reason, according to the Manufacturers discretion, such as improper installation, failure to follow recommended installation and operational instructions, neglect, willful damage, misuse or vandalism, accidental damage, alteration or tampering, or repair by anyone other than the manufacturer, are not covered by this Warranty. The Manufacturer does not represent that this Product may not be compromised and/or circumvented or that the Product will prevent any death and/or personal injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. The Product, properly installed and maintained, only reduces the risk of such events without warning and it is not a guarantee or insurance that such events will not occur. THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS OR LIABILITIES, WHETHER WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE. IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS AFORESAID. THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS, DAMAGE, OR EXPENSE, INCLUDING LOSS OF USE, PROFITS, REVENUE, OR GOODWILL, DIRECTLY OR INDIRECTLY ARISING FROM PURCHASER’S USE OR INABILITY TO USE THE PRODUCT, OR FOR LOSS OR DESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE, EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH, PERSONAL AND/OR BODILY INJURY AND/OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION. However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty, THE MANUFACTURER'S MAXIMUM LIABILITY (IF ANY) SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Manufacturer. When accepting the delivery of the Product, the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so these limitations may not apply under certain circumstances. The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or malfunctioning of any telecommunication or electronic equipment or any programs. The Manufacturers obligations under this Warranty are limited solely to repair and/or replace at the Manufacturer’s discretion any Product or part thereof that may prove defective. Any repair and/or replacement shall not extend the original Warranty period. The Manufacturer shall not be responsible for dismantling and/or reinstallation costs. To exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid and insured. All freight and insurance costs are the responsibility of the Purchaser and are not included in this Warranty. This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the Product only. All products, accessories or attachments of others used in conjunction with the Product, including batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in conjunction with the Products. This Warranty is exclusive to the original Purchaser and is not assignable. This Warranty is in addition to and does not affect your legal rights. Any provision in this warranty which is contrary to the Law in the state or country were the Product is supplied shall not apply. Warning: The user must follow the Manufacturer’s installation and operational instructions including testing the Product and its whole system at least once a week and to take all necessary precautions for his/her safety and the protection of his/her property. 1/08 EMAIL: info@visonic.com INTERNET: www.visonic.com VISONIC LTD. 2012 D-304286 SD-304 PG2 (Rev 2, 12/12) D-304286 SD-304 PG2 Installation Instructions
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : ronnie_s Create Date : 2012:12:13 13:01:48Z Modify Date : 2013:01:17 09:09:21+02:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2013:01:17 09:09:21+02:00 Format : application/pdf Creator : ronnie_s Title : D-304286 SD-304 PG2 Installation Instructions Producer : GPL Ghostscript 8.15 Document ID : uuid:dc6f5f82-b8bc-44e7-89ff-9e336f032276 Instance ID : uuid:56082425-fdb3-4322-ae34-5fe2f3b6c846 Page Count : 6EXIF Metadata provided by EXIF.tools