1032

2015-06-20

: 360 1032 1032 produccion

Open the PDF directly: View PDF PDF.
Page Count: 20

Download1032
Open PDF In BrowserView PDF
Purifier® Logic®+ Class II
Biosafety Cabinets

Purifier Logic + Class II Biosafety Cabinets
®

®

Designed for the HUMAN Experience

The good news is that most biological safety cabinet

Performance

manufacturers build their cabinets to NSF* International

protection having an open front with inward airflow for personnel

Nothing enhances the human experience more than a biosafety
cabinet that allows you to work confidently and with peace of
mind. Unique to the Purifier Logic+ Biosafety Cabinet is its built-in
intelligence to accurately maintain proper airflow, even as the
HEPA filters load. Accuracy is achieved with an Electronically
Commutated Motor (ECM) coupled with Labconco’s exclusive
Constant Airflow Profile™ (CAP) Technology.

protection, downward HEPA filtered laminar airflow for product protec-

The benefits of ECM:

tion, and HEPA filtered exhaust air for environmental protection.”

•	Energy efficiency (see Table 1). The ECM consumes 60% less 	

specifications and have NSF listing. Biosafety cabinets, by their NSF
definition, are designed to be safe:
	

	

“A ventilated cabinet for personnel, product, and environmental

The news gets better. Labconco has added features to its newest

	 energy than conventional motors.
•	Comfortable working temperature. The ECM generates less heat

generation of Purifier Logic+ Biosafety
Cabinets that resets the bar for not

than conventional motors for cooler
working conditions.

only safety but also comfort. Unlike

•	Quiet (< 63 dBA). The ECM

	
	 operates as much as 50% quieter 	
	 than conventional motors.

other cabinets, the Purifier Logic+
was designed for the human body and

•	Reliable. The time-tested ECM 	

	 has a long life (50,000 hour 	
	 average motor life) and reliable 	
	operation.

habits that goes beyond ergonomics.
We call it Inclination™ Technology—
design that caters to human behavior.

•	More power for longer lasting 	

	filters. Because it has greater 	
	 torque than conventional motors, 	
	 the ECM overcomes more resistance 	
	 as HEPA filters load so filters 	
	 last longer.

You experience less fatigue, fewer
distractions and a more comfortable
working environment. Your work
demands precision, attention to
details and constant vigilance to safe
practices. We believe the more comfortable you are, the safer you will be.
	

For total comfort, effortless

operation and maximum safety, the
Purifier Logic+ Biosafety Cabinet is
your logical choice. Read more about
the difference a human-designed biosafety cabinet makes.

•

Performance of Constant Airflow Profile™
•
•

Safety of MyLogic™

Comfort of Inclination™ Technology

* NSF® is a registered trademark of NSF International, Ann Arbor, MI.

Purifier Logic + Class II Biosafety Cabinets
®

®

Designed for the HUMAN Experience

Constant Airflow Profile™ (CAP) Technology is built-in intelligence that works with the ECM to precisely control airflow
without the need for airflow sensors. During operation, the ECM is
constantly adjusting its speed and torque to accurately maintain
its programmed airflow. Tests confirm that airflow is maintained
within 1%.
Using CAP Technology to monitor and provide accurate airflow has
advantages over relying on differential pressure gauges or airflow
sensors. Biosafety cabinets that solely rely on pressure gauges
require manual adjustment by a certifier when readings indicate
a decline in airflow performance. Likewise, airflow sensors have a
known standard of deviation exceeding safe airflow requirements in
Class II cabinets. A certifier can verify safe airflow for a single moment in time. CAP Technology maintains safe airflow all the time.
Sustainable Design
As a member of the U.S. Green Building Council (USGBC), Labconco
is committed to designing environmentally-responsible products. The
Logic+ is one example. Since Logic+ uses less energy and lowers the
heat load compared to cabinets with conventional motors, it contributes toward satisfying EA Credit 1 under LEED. New construction buildings with the Logic+ cabinets installed can earn from one to 19 LEED
points for energy use reduction. The 8.5% pre-consumer and 54.5%
post-consumer recycled content of the Logic+ can contribute towards
satisfying MR Credit 4. Buildings that incorporate recycled materials
may be awarded from one to two LEED points. When it is time to
remove a Logic+ from service, its recyclable content is 94.9%, another
measure of its contribution toward preserving our environment.

Performance Features & Benefits:
•	Reliable ECM provides energy-efficient operation.
•	CAP Technology assures consistent delivery of precise air 		

	 volume, even as filters load. No sensors are needed.
•	Low lifetime cost (see Table 1). Energy efficiency and lower 	

	 maintenance costs add up to a lower total lifetime cost.
•	Air-Wave™ Entry System, consisting of aerodynamic angles 	
	 surrounding the access opening, provides less airflow resis-		
	 tance for better containment.
•	Contain-Air™ Negative Pressure Channel draws air in, 		

	 preventing loss of containment at the top of the sash. 	
•	Smart-Start™ System automates routine start up and shut 		

	 down functions, assuring consistent operation regardless of 		
	 the user and saves time.
•	Night-Smart™ System idles the blower at 30% speed when 		

	
	
	
	

the sash is fully closed to help maintain a clean environment 	
inside the cabinet during periods of non-use while saving 		
energy. When the sash is raised, the blower automatically 		
resumes normal operation.

•	5 year warranty

* LEED® is a registered trademark owned by the U.S. Green Building Council and is used with permission.

Table 1. 4' Purifier Logic+ Biosafety Cabinet Energy Usage and Operating Costs & Comparison

			

Logic+		

Other Cabinet A	

Other Cabinet B	

	 Motor Type/Technology		
DC ECM		
AC PSC	
AC-3Ø	
		 8 hrs/day (2,080 hrs/year)*						
		 Energy Used (kWh/yr)		
603		
1206	
861	
		 Annual Cost - Commercial		
$60 		
$121 	
$86 	
		 Annual Cost - Industrial		
$41 		
$81 	
$58 	
	 24 hrs/day (8,736 hrs/year)*						
		 Energy Used (kWh/yr)		 2533 (803**)		
5067	
3617	
		 Annual Cost - Commercial		 $253 ($80**) 		
$507 	
$362 	
		 Annual Cost - Industrial		 $170 ($54**) 		
$341 	
$243 	
	 15-Year Life Cycle Costs† Operational Costs
		 Annual Certification		
$2,250		
$2,250	
$2,250	
		 Energy Cost - 8 hrs/day (Industrial)		
$609 		
$1,217 	
$869 	
		 Energy Cost - 24 hrs/day (Industrial)		 $2,557 ($811**)	 	
$5,115 	
$3,651 	
	 Total Operational Cost (8 hr/day)		
$2,859		
$3,467	
$3,119	
	 Total Operational Cost (24 hr/day)		$4,807 ($3,061**)		
$7,365	
$5,901	
	 Maintenance Costs
		 HEPA Filter Costs		
$800 		
$1,600 	
$1,600 	
		 Service Cost 		
$3,000 		
$3,450 	
$3,450 	
		 Replacement Parts		
$700 		
$1,100 	
$1,100 	
	 Total Maintenance Cost		$2,250		
$3,900	
$3,900	
	 Total Lifetime Cost (8 hr/day)		
$5,109 		
$7,367 	
$7,019 	
	 Total Lifetime Cost (24 hr/day)	
	$7,057 ($5,311**)	 	
$11,265 	
$9,801 	
††

Other Cabinet C	
DC
339
$34
$23
1424
$142
$96
$2,250		
$342
$1,438
$2,592
$3,688
$2,400
$4,350
$2,500
$7,000
$9,592
$10,688

*	Using a Commercial Business Energy use cost of $0.0988/kWh and an Industrial Energy use cost of $0.0673/kWh. ** Continuous operation of cabinet utilizing Night-Smart™ reduced flow setback mode. Calculations based 	
	 on using Night-Smart™ idle setback 16hr/day for 5 days/wk and 24 hr/day for 2 days/week, 52 week calendar year. † Costs of HEPA filters, service and replacement parts are approximations, not an estimate or guarantee 	
	 of any kind. †† Service cost includes annual certification ($150/yr), decontamination ($450/incident), and incidentals.

3

Purifier Logic + Class II Biosafety Cabinets
®

®

Designed for the HUMAN Experience

Safety
The most important reason to choose the Purifier Logic+ is safety.
You simply won’t find another biosafety cabinet with a more
comprehensive safety package than the Logic+. Purifier Logic+
Biosafety Cabinets meet or exceed all minimum requirements set
by NSF International including 99.99% efficient HEPA filters and
nominal inflow of 105 fpm. The Logic+ goes well beyond the NSF
Standard by providing the user with peace of mind that airflow is
within normal limits and the HEPA filters are working properly. A full
color, line-of-sight LCD information center, which is in constant
communication with the ECM, continuously monitors and displays
the cabinet’s performance.
The benefits of the LCD information center:

Various alert and alarm messages may be displayed and provide clear feedback and instruction.

•	Easy readability with MyLogic™ OS. The large full color display 	

	
	
	
	

runs on MyLogic™ OS that provides user-friendly programming 	
and feedback. Mounted on the interior right side wall of the 	
user’s line of sight while seated, the display shows cabinet
	
function, filter loading and systems in use.

•	Descriptive feedback in easy-to-understand full sentences 	

	 leaves nothing to interpretation. Step-by-step instruction 	
	 guides you when programming features such as Smart-Start and 	
	Night-Smart.
•	“Filter Remaining” bar graph. A bar graph depicts 		

	
	
	
	

percent of HEPA filter life remaining to provide assurance and 	
allow you to accurately and confidently plan for future filter 	
replacement. Alerts warn when the filter life diminishes to 20% 	
and 0%.

•	Alerts and Alarms. Visual and audible alarms warn users of 	
	 cabinet errors, explain the meaning of the alarm, diagram where 	
	 the cabinet has been affected, and provide intuitive trouble-	
	 shooting tips.

Safety Features & Benefits:
•	Line-of-sight Information Center with MyLogic™ OS 		
	 provides at-a-glance assurance that your cabinet is 		
	 operating safely.
•	Fully-closing, tempered safety glass sash. An audible/		

	 visual alarm indicates when the sash is opened above its 		
	 working height.
•	Reserve-Air™ Inflow Slots on the inlet grille draw air into 	
	 the cabinet to maintain safe airflow should the user inad-		
	 vertently block portions of the grille while resting arms.
•	NSF-approved Vacu-Pass™ Cord & Cable Portal, avail-		

•	Durable construction. The display is constructed of UV-opaque 	

	 able on some models, safely allows passage of electrical 		
	 cords and tubing through the side of the cabinet without 		
	 air leakage or airflow disruption. See page 9 for	more		
	information.

	 safety glass and stainless steel for easy decontamination.

•	Electronic security lock, when enabled, prevents operation 	

	 of the cabinet by unauthorized users.
•	NSF listed*
Bar graph displays
percent of
HEPA filter life
remaining

4

* Applies to Purifier Logic+ Class II, Type A2 and B2 Biosafety Cabinets

Purifier Logic + Class II Biosafety Cabinets
®

®

Designed for the HUMAN Experience

Inclination Technology has been applied throughout the cabinet. While seated, the LCD information center is within sight and the touchpad controls are within reach. Greater comfort lessens
the risk of accidents and personal injury.

Comfort
Labconco’s Inclination™ Technology—features that reinforce what
humans are inclined to do—is nothing new to us. We’ve been at
the forefront of designing ergonomics and comfort features into our
biosafety cabinets for decades. For example, in 1983, we pioneered
the use of an angled sash, which allows closer, more comfortable
viewing without glare. We thoughtfully design every feature to
ensure that form follows function and the shape of the human body.

The curved inlet grille provides a comfortable
surface for forearms resting on it. No additional armrest is needed. Reserve-Air ™ Inflow
Slots draw air into the cabinet should the operator inadvertently block portions of the inlet grille,
maintaining safe airflow.

Unobtrusive lift knobs on the front corners of the dished
stainless steel work surface allow it to be quickly lifted
for cleaning.

The electrical outlet cover may be opened with one finger and then gently and slowly
self closes. It mounts flush and flat against the side wall for easy cleaning.

Scan this code to view a
brief video showing some of
the Inclination Technology
features in action.

5

Purifier Logic + Class II Biosafety Cabinets
®

®

Designed for the HUMAN Experience

Comfort Features & Benefits:
25.6 "

• ECM is quieter and cooler than comparable PSC motors.
•	Line-of-sight, full color LCD information center is visible 	

21"

	 to the user while seated at the cabinet.
•	ADA-compliant, easy-to-clean touchpad controls allow 		

	 manual activation of blower, timer, audible alarm mute and 	
	 menu selection.

10" Sash
8" Sash

•	ADA-compliant service fixtures, available factory- or 		

8"

10"

Worktop Ht.
35"

	
	
	
	
	

user-installed, are mounted within easy reach on the side 		
walls, 8.5" (20 cm) above the work surface to maximize 		
usable surface area, permit free arm movement and 		
allow easy removal of the work surface. See page 9 for 		
more information.

•	Curved inlet grille gently supports the user’s forearms 		

	 without the need for uncomfortable, hard-to-clean armrests.
32.5"

•	Flush-mounted electrical duplex covers have dampened 		

	 hinges that close slowly rather than snapping shut 		
	 on fingers. Surfaces are easy-to-clean stainless steel.
6"

•	Counterweighted sliding sash with anti-racking 		

	mechanism may be raised and lowered with minimal effort.
•	Large interior work area offers more cubic feet than any 		

	 other brand.
•	Inclined sash is sloped at 10° for closer, more 			

	 comfortable viewing than vertical sashes offer. Two small, 		
	 sculptured sash handles on the outside surface of the sash 	
	 do not obstruct the view of the interior.

24.6"

19"

•	Over 27" (69 cm) of viewing height gives greater visual 		

	accessibility.
•	Bright, glare-free fluorescent lighting with timer pro-		

	 vides 90-100 footcandles at the work surface, exceeding 		
	 NSF requirements.

10" Sash
8" Sash

8" 10"
Worktop Ht.
33"

8"

30.5"

6"

6

Ergonomic principles were applied to the design of the Purifier Logic+ Biosafety Cabinet to ensure
that humans of all sizes maintain a healthy posture, and have good visibility and range of motion
while using the cabinet. The illustrations above show an adult male of an average height of 5' 9.1"
and an adult female of an average height of 5' 3". The accessory base stand, chair and footrest
work together to achieve the proper height for individuals using the cabinet.

Purifier Logic + Class II Biosafety Cabinets
®

®

Type A2 & B2 — Which do you Choose?

Select the right Purifier Logic Biosafety
Cabinet for your application
Purifier Logic+ Class II Biosafety Cabinets come in Type
A2 and Type B2 configurations. The airflow diagrams below
illustrate the differences between the two Types. Which configuration you choose is determined by your application. Both Type
A2 and B2 cabinets are suitable for work with agents that require
Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antioneoplastic drugs, genetic material,
carcinogens, allergens and additional substances that generate
hazardous airborne particulates.
Purifier Logic+ Class II, Type A2 Biosafety Cabinets are
designed to discharge HEPA-filtered exhaust air directly into the

laboratory, or into an exhaust system through the optional Canopy
Connection. When canopy-connected, the biosafety cabinets may
be used for applications involving volatile toxic chemicals and
radionuclides as an adjunct to microbiological research. These
benchtop cabinets are available in 3', 4', 5' and 6' nominal widths.
See pages 10-11 for ordering information.
Purifier Logic+ Class II, Type B2 Biosafety Cabinets are
designed to be hard ducted to the outside. Since none of the air
is recirculated, these cabinets may be used for work with agents
treated with volatile toxic chemicals and radionuclides. These
benchtop cabinets are available in 4' and 6' nominal widths. 	
See pages 12-13 for ordering information.

~30% Exhausted

100% Exhausted

~70% Recirculated

0% Recirculated

Class II, Type B2 Airflow

Class II, Type A2 Airflow
During operation, room air is drawn into the inlet grille. The air in
the plenum beneath the work surface is a mixture of unfiltered room
air, and air that has just passed through the work area. This contaminated air is drawn by the blower through the back plenum of the
cabinet, where approximately 70% of the air is recirculated through
the supply HEPA filter and back over the work area. The balance of
the contaminated air is discharged to the environment after passing
through the exhaust HEPA filter.
Room Air

HEPA-Filtered Air

During operation, room air is drawn through the top of the cabinet.
This air is HEPA filtered, and then flows downward through the work
area. Room air is also drawn into the inlet grille. All of the contaminated air is drawn under the work surface or through the rear grille,
then up the rear plenum, and through the exhaust HEPA filter.
A dedicated exhaust system and remote blower draw 100% of the
filtered exhaust air out of the laboratory. The ductwork and remote
blower are required for operation and sold separately.
Unfiltered Air under
Negative Pressure

Unfiltered Air under
Positive Pressure

7

Purifier Logic + Class II Biosafety Cabinets
®

®

Optional Features & Benefits

Specialized work requires special features
Cell research often involves using a microscope, keeping the cells
at the proper temperature for viability, or both. At the same time,
the work must be conducted in a biological safety cabinet to protect the cells, researcher and environment. The Purifier Cell Logic+
Biosafety Cabinet has special features that address the unique
needs of cell research.

Cell Logic+ Features & Benefits:
•	Scope-Ready™ package option. Models are available that 		

	 allow a customer-supplied microscope to be integrated into 	
	 the cabinet. The sash has a 7.0" wide x 10.5" high (18 x27cm) 	
	 cutout that accommodates most microscopes’ eyepieces.
	 •	The Pure-Vu™ Seal, made of flexible and clear material, 		

		
		
		
		
		
		

surrounds the cutout preventing contaminants from 		
escaping while providing ergonomic visibility into the 		
cabinet. Modified ASHRAE 110 and NSF 49 testing confirms 	
that this unique teardrop collar design keeps contaminants 	
contained. An accessory Pure-Vu™ XL Seal is available to 		
accommodate forward-mounted microscopes.

	 •	The Stand-Still™ Isolation Platform completes the 		

		Scope-Ready™ package and is sold separately. The platform 	
		 supports the microscope on the cabinet’s work surface and 	
		 reduces vibration threefold. Modified ASHRAE 110 and NSF 	
		 49 testing confirms this elevated aerodynamic base 		
		 maintains safe airflow. Constructed of seamless Type 304 	
		 stainless steel, the non-porous platform is easy to clean 		
		 and autoclavable. The platform is available in two sizes 		
		 and is sold separately.
•	Temp-Zone™ package option. Models are available that 		

	
	
	
	
	
	
	
	
	
	

include a temperature-controlled area on the work surface, 	
10.5" wide x 12.0" deep (7.0" wide x 12.0" deep on 3' 		
models). Warmed or chilled samples may be transferred to 		
the Temp-Zone and kept at optimum temperature. Quick 		
connection fittings on the left side of the cabinet attach to 	
a user-supplied circulator that continually delivers chilled or 	
heated liquid to the Temp-Zone area. Uniform temperature 	
distribution is maintained on the surface. Easy-Clean™ Prop 	
Rods allow for hands-free elevation of the work surface for 	
ease of cleaning and access to the channels and drain.

* American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA

The accessory Pure-Vu Seal and Stand-Still XL Isolation
Platform accommodate forward-mounted microscopes such
as stereo scopes.

8

The Temp-Zone package option includes the temperature-controlled area of the work surface (shown above left) and
the Easy-Clean Prop Rods (shown above right).

Purifier Logic + Class II Biosafety Cabinets
®

®

Optional Features, Benefits & Accessories

Accessory Package adds functionality to
your biosafety cabinet
The optional Accessory Package caters to your unique biosafety
cabinet wants and needs. Three features are factory-installed so
that you can put them to immediate use: UV lamp, service fixture
and Vacu-Pass Cord & Cable Portal.
The 254 nm UV lamp
provides secondary decontamination while the
cabinet is not in use.
An interlocked switch
permits the UV light
to operate only when
the sash is completely
closed.

The service fixture
supplies water, vacuum,
air or noble gases to the
cabinet interior. It has
a ball-type valve that
provides smooth operation at pressures up to
40 psi. The serrated
hose tip valve with
quarter turn control handle is mounted 8.5" (20 cm) above the
work surface to maximize usable surface area. One service fixture is
mounted on the right-hand side on 3', 4' and 5' models with
Accessory Package. Two service fixtures, one on each side, come
with 6' models with Accessory Package.

The Vacu-Pass™ Cord &
Cable Portal combines
safety and convenience.
The portal allows passage of cords through
the side wall of the
cabinet so that cords
are kept out of the way
of the user’s work area.
The NSF-approved port does not disrupt the cabinet’s airflow or
allow leakage to occur. One portal comes mounted on the righthand side interior on models with Accessory Package. A plug seals
the opening when not in use.

Telescoping Base Stand (non-welded)
For ease of ordering, some models of the Purifier Logic+ and
Cell Logic+ Biosafety Cabinets include the Telescoping Base
Stand. The stand is shipped unassembled allowing it to be sent
in the same package with the biosafety cabinet. The base stand
includes a free shelf and has telescoping legs so that the appropriate height for your application and user can be selected during
installation.

Ventus™ Canopy Connection provides
ducting for your Class II, Type A2 cabinet
Certain applications, such as working with malodorous samples, small
amounts of volatile toxic chemicals and tracer quantities of radionuclides, require the connection of your Class II, Type A2 cabinet to an
exhaust system. The NSF-approved Ventus Canopy Connection
mounts above the biosafety cabinet to allow thimble ducting to the
outside. Unlike canopies that rely on imprecise pressure or airflow
sensors, the Ventus has an uncomplicated mechanical design that
ensures safe and reliable operation. In less than one second after a
low flow event is detected, the alarm on the LCD alerts the user while
the blower speeds to full capacity to maximize personal safety. The
low profile Ventus adds only 1.25" to the overall height of the cabinet.

These accessories and more are also available
for on-site installation. See Accessories and Base Cabinets
Ordering Information starting on page 15.
9

Purifier Logic + Class II, Type A2 Biosafety Cabinets
®

®

Catalog Number Configurator

Use this key to configure the nine digit catalog number to order your Purifier Logic+ or Cell Logic+ Class II, Type A2 Biosafety
Cabinet. For example, a 302311100 is a 3' Purifier Logic+ Class II, Type A2 Biosafety Cabinet with 10" sash opening, service
fixture, UV lamp, Vacu-Pass Portal, non-welded base stand and North America, 115 volt electrical receptacle and plug.
STEP 1: Select the Cell Logic+ package(s)
option. This number is the second digit of
your catalog number.

STEP 2: Select the width of your cabinet.
This number is the fourth digit of your
catalog number.

0 =	None. Logic+ only.
2 =	Temp-Zone Package. Fifth digit is 9 		

3 = 3' (Actual width = 42.3"/107.4 cm)
4 = 4' (Actual width = 54.3"/137.9 cm)
5 = 5' (Actual width = 66.3"/168.4 cm)
6 = 6' (Actual width = 78.3"/198.9 cm)

	

and sixth digit is 1.

3 =	Scope-Ready Package. Fifth digit is 9 		
	

and sixth digit is 1.

STEP 3: Select the sash opening height.
This number is the fifth digit of your
catalog number.
1 = 10" (25.4 cm). Logic+ only.
8 = 8" (20.3 cm). Logic+ only.
9 = 9" (22.9 cm). Cell Logic+ only.

4 =	Temp-Zone & Scope-Ready Packages. 		
	

Fifth digit is 9 and sixth digit is 1.

3

_

2

_

_

_

North America,
115 volts, 20 amps
Japan, 100 volts,
20 amps*

115 volt, 15 amp
115 volt, 15 amp

India

For Catalog
For Catalog
Numbers ending
Numbers ending
British (UK)
in 00 & 20 British (UK)
in 00 & 20

India

For Catalog
Numbers
India
ending in 10

115 volt, 20 amp
British (UK)

115 volt, 15 amp

Schuko

115 volt, 20 amp
115 volt, 20 amp

115 volt, 20 amp

115 volt, 15 amp

British (UK)

North America,
230 volts

_

115 volt, 20 amp

115 volt, 15 amp

Electrical Receptacle & Plug Configurations
North America,
115 volts, 15 amps
Japan, 100 volts,
15 amps

_

STEP 6: Select the electrical receptacle and plug type.
This number is the eighth and ninth digits of your
catalog number.
00 = North America, 115 volts (15 amps for 3' and 4' 		
	
models. 20 amps for 5' and 6' models)
10 = North America, 230 volts
20 = Japan, 100 volts (15 amps for 3' and 4' models. 		
	
20 amps for 5' and 6' models)
30 = Schuko, 230 volts	
40 = China/Australia, 230 volts
50 = British (UK), 230 volts	
70 = India, 230 volts

STEP 5: Select nonwelded telescoping
base stand option.
This number is the
seventh digit of your
catalog number.
0 =	None
1 = 	Includes an 		
	 non-welded tele-	
	 scoping base stand 	
	 shipped with the 	
	cabinet.

STEP 4: Select the Accessory Package
option: service fixture(s), UV lamp and
Vacu-Pass™ Cord & Cable Portal. This number is the sixth digit of your catalog number.
0 = 	None. Logic+ only.
1 =	 Includes a right-side mounted
	
	 factory-installed service fixture (two on
	
	 6' models, one on each side), UV lamp 	
	 with timer (UV lamp not included with 	
	 Scope-Ready), and right-side wall 		
	 Vacu-Pass Portal. Comes standard on 	
	 all Cell Logic+ models.

_

Schuko,
China/Australia
230 volts

North America 230 volt

British (UK)

China/Australia,
230 volts

For Catalog
Numbers
China/Australia
ending in 40

115 volt, 15115
amp
volt, 15 amp

British (UK),
230 volts

India

China/Australia

Schuko

For Catalog
Numbers
ending in 30

Schuko

India

British (UK)British (UK)

For Catalog
Numbers
Schuko
ending in 50

North America 230 volt

Schuko

For Catalog
Numbers
ending in 70

Technical Specifications
	 Nominal Width	
	
	
	
	
	
	

Actual Width	 Schuko Schuko
Shipping Weight	
Shipping Weight including stand	
Exhaust Volume, 10" Sash Opening	
Exhaust Volume, China/Australia
8" Sash
Opening	
China/Australia
Exhaust Volume, 9" Sash Opening	

3'	

4'	

42.3" (107.4 cm)	
510 lbs. (231 kg)	
585 lbs. (265 kg)	
253-279 CFM	
203-223 CFM	
228-251 CFM	

54.3" (137.9 cm)	
585 lbs. (265 kg)	
670 lbs. (304 kg)	
339-370 CFM	
269-296 CFM	
304-333 CFM	

12	
12	
6	

12	
12	
6	

	 Electrical Configuration	
	 115 volts, 60 Hz	
North America 230 volt
America 230 volt
	 100 volts, 50/60NorthHz	
	 230 volts, 50/60 Hz	

10

5'	

North America 230 volt

66.3" (168.4 cm)	
715 lbs. (324 kg)	
810 lbs. (367 kg)	
420-462 CFM	
336-370 CFM	
378-416 CFM	

6'
China/Australia
China/Australia

78.3" (198.9 cm)
805 lbs. (365 kg)
905 lbs. (411 kg)
503-554
CFM
North America
230
volt 230 volt
North
America
403-443 CFM
453-498 CFM

Amperage

Contact Labconco for ordering information on models that are EN 12469 compliant.
* Plug is 20 amps. Receptacle is 15 amps.

16	
16	
8	

115 volt, 20115
amp
volt, 20 amp

India, 230 volts

16
16
8

India

India

Purifier Logic + Class II, Type A2 Biosafety Cabinets
®

®

Specifications

Comfort Features

Purifier Logic+ Class II, Type A2
Biosafety Cabinet 302411100

• Interior-mounted, line-of-sight, full color LCD information center
with easy-to-understand MyLogic™ OS
• 21.7" (54 cm) maximum sash opening height and 27.0" (69 cm)
viewing height
• Curved inlet grille for forearm support
•	 Flush-mounted stainless steel electrical receptacle covers with
dampened hinges
• Removable, seamless type 304 stainless steel, dished work surface
with lift out knobs
• 10° Angled sash with counterbalanced, anti-racking mechanism
for ease of lifting
• ADA-compliant touchpad control on right-hand side post for
manual activation of blower, light(s), timer, electrical receptacles, audible alarm mute and menu selection
•	Noise level < 63 dBA
•	Heat load 990 BTU/hour (4' models)

Specifications
Performance Features
• Electronically Commutated Motor (ECM)
• Constant Airflow Profile™ (CAP) Technology airflow monitoring
system that communicates with the ECM to deliver the precise
volume of air as required and automatically adjust as filters load
without relying on airflow sensors
•	 Air-Wave™ Entry System*
• Contain-Air™ Negative Pressure Channel*
• Smart-Start™ System that allows the user to program start up 	
and shut down operations
• Night-Smart™ System that idles the blower when the sash is 	
fully closed
• Built-in interval or elapsed timer for experiment monitoring,
fluorescent light or UV light control (on models with UV light)
• Digital clock
•	Removable towel catch located under work surface
• Bright, 90-100 footcandle, glare-free fluorescent lighting located
outside the contaminated work area
• Five year warranty

Safety Features
• LCD information center with “Filter Life Remaining” bar graph,
status line for alarm conditions and alerts to warn when filter life
diminishes to 20% and 0%
• Electronic security lock (optional activation) that requires code
to operate the cabinet
• Two electrical duplex receptacles, (single outlets on 230 volt
models), located one on each side, with ground fault interruption (115 volt models)
•	Intrinsically safe negative pressure design
• Fully-closing, clear 1/4" tempered safety glass sash
• Stainless steel inlet grille with Reserve-Air™ Secondary Airflow
Slots*
•	Supply and exhaust 99.99% efficient HEPA filters. Contact
Labconco for optional 99.999% efficient ULPA filters.
• Leak-tight stainless steel interior

• Nominal inflow velocity of 105 feet per minute (fpm) (0.5 m/sec)
•	Nominal downflow velocity of 55 fpm (0.3 m/sec)
•	Approximately 70% air recirculation
•	Powder-coated steel exterior
• NSF International listed (Logic+ models). NSF International and
modified ASHRAE 110 compliant (Cell Logic+ models).
• ETL listed
• CE conformity marking (230 volt models)
•	Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100)
•	Overall depth x height: 31.2" x 61.7" (79.2 x 156.7 cm)
• 10' (3 m) power cord with plug

Options
• Non-welded, NSF-Approved, powder-coated steel telescoping base
stand with fixed feet
• Accessory Package: 254 nm UV lamp, ADA-compliant service
fixture(s) with ball-type valve(s), and NSF-Approved Vacu-Pass™
Cord & Cable Portal
•	Cell Logic+ Packages: Scope-Ready™ Package consisting of 7.0"
wide x 10.5" high (18 x 27 cm) sash cutout and Pure-Vu™ Seal
with powder-coated steel collar. Stand-Still™ Isolation Platform
is required and sold separately. See page 16. Temp-Zone™
Package consisting of temperature-controlled work area, 10.5"
(27 cm) wide x 12.0" (30 cm) deep (7.0" x 12.0" on 3' models)
located on the left side of the work surface. Circulator is
required (not included). Circulator requirements: minimum flow
rate of 0.4-0.5 GPM (1.5-1.9 LPM), typical volume of 6 liters, and
temperature of 0-50° C (chiller/heater).
• Ventus™ Canopy Connection, NSF-Approved, with low flow design
and audio/visual alarms (adds 1.25" to overall cabinet height)

Required Accessory
• Supporting base if non-welded stand option is not selected
Exclusive Labconco feature

*U.S. Patent No. 6,368,206

Complies with Americans with Disabilities Act Standard for height of controls and receptacles

See Dimensional Data on page 14, Accessories on pages 15-17,
and Base Stands on pages 18-20.

11

Purifier Logic + Class II, Type B2 Biosafety Cabinets
®

®

Catalog Number Configurator

Use this key to configure the nine digit catalog number to order your Purifier Logic+ or Cell Logic+ Class II, Type B2 Biosafety
Cabinet. For example, a 303481100 is a 4' Purifier Logic+ Class II, Type B2 Biosafety Cabinet with service fixture, UV lamp,
Vacu-Pass Portal, non-welded base stand and North America, 115 volt electrical receptacle and plug.
STEP 1: Select the Cell Logic+ package(s)
option. This number is the second digit of
your catalog number.

STEP 2: Select the width of your cabinet.
This number is the fourth digit of your
catalog number.

0 =	None. Logic+ only.
2 =	Temp-Zone Package. Sixth digit is 1.
3 =	Scope-Ready Package. Sixth digit is 1.
4 =	Temp-Zone & Scope-Ready Packages. 		

4 = 4' (Actual width = 54.3"/137.9 cm)
6 = 6' (Actual width = 78.3"/198.9 cm)

	

Sixth digit is 1.

3

_

3

_

8

STEP 4: Select nonwelded telescoping
base stand option.
This number is the
seventh digit of your
catalog number.
0 =	 None
1 =	 Includes an 		
	 non-welded tele-	
	 scoping base 		
	 stand shipped 		
	 with the cabinet.

STEP 3: Select the Accessory Package
option: service fixture(s), UV lamp and
Vacu-Pass™ Cord & Cable Portal. This number is the sixth digit of your catalog number.
0 =	 None. Logic+ only.
1 =	 Includes a right-side mounted
	
	 factory-installed service fixture (two on
	
	 6' models, one on each side), UV lamp 	
	 with timer (UV lamp not included with 	
	 Scope-Ready), and right-side wall 		
	 Vacu-Pass Portal. Comes standard on 	
	 all Cell Logic+ models.

115 volt, 15 amp

British (UK)

Schuko

_

_

_

_

STEP 5: Select the electrical receptacle and plug type.
This number is the eighth and ninth digits of your
	
catalog number.
00 = North America, 115 volts (15 amps for 4' 			
models. 20 amps for 6' models)
10 = North America, 230 volts
20 = Japan, 100 volts (15 amps for 3' and 4' models. 		
	
20 amps for 5' and 6' models)
30 = Schuko, 230 volts	
40 = China/Australia, 230 volts
50 = British (UK), 230 volts	
70 = India, 230 volts
115 volt, 20 amp

115 volt, 20 amp

115 volt, 15 amp

India

115 volt, 20 amp
British (UK)

115 volt, 15 amp

India

Electrical Receptacle & Plug Configurations
North America,
115 volts, 15 amps
Japan, 100 volts,
15 amps

North America,
115 volts, 20 amps
Japan, 100 volts,
20 amps*

115 volt, 15 amp
115 volt, 15 amp

For Catalog
For Catalog
Numbers ending
Numbers ending
British (UK)
in 00 & 20 British (UK)
in 00 & 20

North America,
230 volts

115 volt, 20 amp
115 volt, 20 amp

India

For Catalog
Numbers
India
ending in 10

Schuko,
China/Australia
230 volts

North America 230 volt

For Catalog
Numbers
ending in 30

British (UK)

China/Australia,
230 volts

Schuko

China/Australia

Schuko

For Catalog
Numbers
China/Australia
ending in 40

115 volt, 15115
amp
volt, 15 amp

British (UK),
230 volts

India

British (UK)British (UK)

For Catalog
Numbers
Schuko
ending in 50

North America 230 volt

Schuko

For Catalog
Numbers
ending in 70

Technical Specifications
	 Nominal Width	
Schuko

Schuko

	 Exhaust Volume**	
	CBV †	
	 Shipping Weight	
	 Shipping Weight including stand	

4'	
665 CFM	
810 CFM @ 1.9"	
650 lbs. (295 kg)	
730 lbs. (331 kg)	

China/Australia
China/Australia

	 Electrical Configuration	

	 115 volts, 60 Hz	
	 100 volts, 50/60 Hz	
North America 230 volt
	 230 volts, 50/60NorthHz	
America 230 volt

12

North America 230 volt

6'
998 CFM
1218 CFM @ 2.2"
840 lbs. (381 kg)
940 lbs. (426 kg)

Amperage
12	
12	
6	

12
12
8

* Plug is 20 amps. Receptacle is 15 amps.	
**	Exhaust Volume values are obtained using a Direct Inflow Measurement (DIM) meter sealed to the front of the cabinet.
†	Concurrent Balance Values (CBV) are obtained using a Pitot or thermal anemometer traverse of the exhaust duct.
Static pressure is the amount of vacuum required at the cabinet connection when the HEPA filters are new.

115 volt, 20115
amp
volt, 20 amp

India, 230 volts

China/Australia
China/Australia

North America
230
volt 230 volt
North
America

India

India

Purifier Logic + Class II, Type B2 Biosafety Cabinets
®

®

Specifications

Comfort Features

Purifier Logic+ Class II, Type B2
Biosafety Cabinet 303481100

• Interior-mounted, line-of-sight, full color LCD information center
with easy-to-understand MyLogic™ OS
• 21.7" (54 cm) maximum sash opening height and 27.0" (69 cm)
viewing height
• Curved inlet grille for forearm support
• Flush-mounted stainless steel electrical receptacle covers with
dampened hinges
• Removable, seamless type 304 stainless steel, dished work surface
with lift out knobs
• 10° Angled sash with counterbalanced, anti-racking mechanism
for ease of lifting
• ADA-compliant touchpad control on right-hand side post for
manual activation of blower, light(s), timer, electrical receptacles, audible alarm mute and menu selection
•	Noise level < 63 dBA
•	Heat load 990 BTU/hour (4' models)

Specifications
Performance Features
• Electronically Commutated Motor (ECM)
• Constant Airflow Profile™ (CAP) Technology airflow monitoring
system that communicates with the ECM to deliver the precise
volume of air as required and automatically adjust as filters load
without relying on airflow sensors
•	Air-Wave™ Entry System*
• Contain-Air™ Negative Pressure Channel*
• Smart-Start™ System that allows the user to program start up and
shut down operations
• Built-in interval or elapsed timer for experiment monitoring,
fluorescent light or UV light control (on models with UV light)
• Digital clock
•	Removable towel catch located under work surface
• Bright, 90-100 footcandle, glare-free fluorescent lighting located
outside the contaminated work area
• Five year warranty

Safety Features
• LCD information center with “Filter Life Remaining” bar graph,
status line for alarm conditions and alerts to warn when filter life
diminishes to 20% and 0%
• Electronic security lock (optional activation) that requires code to
operate the cabinet
• Two electrical duplex receptacles, (single outlets on 230 volt
models), located one on each side, with ground fault interruption
(115 volt models)
•	Intrinsically safe negative pressure design
• Fully-closing, clear 1/4" tempered safety glass sash with 8" (20 cm)
working height opening
• Stainless steel inlet grille with Reserve-Air™ Secondary Airflow
Slots*
•	Supply and exhaust 99.99% efficient HEPA filters. Contact
Labconco for optional 99.999% efficient ULPA filters.
• Leak-tight stainless steel interior

• Nominal inflow velocity of 105 feet per minute (fpm) (0.5 m/sec)
•	Nominal downflow velocity of 55 fpm (0.3 m/sec)
•	0% air recirculation
•	Powder-coated steel exterior
• NSF International listed (Logic+ models). NSF International and
modified ASHRAE 110 compliant (Cell Logic+ models).
• ETL listed
• CE conformity marking (230 volt models)
•	Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100)
•	Overall depth x height: 31.2" x 61.7" (79.2 x 156.7 cm)
• 10" diameter exhaust outlet with air-tight damper
• 10' (3 m) power cord with plug

Options
• Non-welded, NSF-Approved, powder-coated steel telescoping
base stand with fixed feet
• Accessory Package: 254 nm UV lamp, ADA-compliant service
fixture(s) with ball-type valve(s), and NSF-Approved Vacu-Pass™
Cord & Cable Portal
•	Cell Logic+ Packages: Scope-Ready™ Package consisting of
7.0" wide x 10.5" high (18 x 27 cm) sash cutout and Pure-Vu™
Seal with powder-coated steel collar. Stand-Still™ Isolation
Platform is required and sold separately. See page 16.
Temp-Zone™ Package consisting of temperature-controlled work
area, 10.5" wide x 12.0" deep (27 x 30 cm) located on the left
side of the work surface. Circulator is required (not included).
Circulator requirements: minimum flow rate of 0.4-0.5 GPM
(1.5-1.9 LPM), typical volume of 6 liters, and temperature of
0-50° C (chiller/heater).

Required Accessory
• Supporting base if non-welded stand option is not selected

Exclusive Labconco feature

*U.S. Patent No. 6,368,206

Complies with Americans with Disabilities Act Standard for height of controls and receptacles

See Dimensional Data on page 14, Accessories on pages 15-17,
and Base Stands on pages 18-20.

13

C

C

Exhaust Outlet
10.0"Outlet
(25.410.0"
cm) ID
Exhaust
(25.4 cm) OD

9.1"
9.1"
(23.1 ®cm) (23.1 cm)

Purifier Logic + Class II, Biosafety Cabinets
®

Dimensional Data

Class II, Type A2

2.0" (5.1 cm)

Exhaust Outlet 10.0" (25.4 cm) ID

C

Optional Ventus
™ Ventus ™
Optional
Canopy Connection
Canopy Connection

9.1"
(23.1 cm)

63.3" (160.8
cm)(166.1 cm)
65.4"
with Optional
with Optional
Ventus ™ Canopy
Ventus ™ Canopy
ConnectionConnection

61.7"*
61.7"*
(156.7 cm) (156.7 cm)
Overall
Overall

TOP
2.0" (5.1 cm)

	Nominal	A	
B	
C	
	Width	 Inches/cm	 Inches/cm	Inches/cm
	
3'	 42.3/107.4	 36.5/92.7	13.6/34.5
	 4'	 54.3/137.9	 48.5/123.2	19.9/50.5
	 5'	 66.3/168.4	 60.5/153.7	26.9/68.3
	 6'	 78.3/198.9	 72.5/184.2	32.9/83.6

Optional Optional
8.0", 9.0" or
10.0"
8.0",
10.0" or 9.0"
Scope-Ready
™
(20.3, 22.9(20.3,
or 25.4
cm)or 22.9
™
25.4
cm) Scope-Ready
Working Height
Working HeightPackage Package
™
Optional Ventus21.7"
(55.121.7"
cm) (55.1 cm)
Canopy Connection
MAX
MAX

C
8.8"
(22.4 cm)

8.8"
(22.4 cm)

C

Exhaust Outlet
10.0"Outlet
(25.4 10.0"
cm) OD
Exhaust
(25.4 cm) OD

B
B
63.3" (160.8 cm)
A with Optional
A
Ventus ™ Canopy

FRONT
Connection

61.7"*
(156.7 cm)
Overall

25.7"
25.7"
(65.3 cm) (65.3 cm)

29.2"
29.2"
(74.2 cm) (74.2 cm)

17.6"
17.6"
(44.7 cm) (44.7 cm)
31.2"
31.2"
(79.2 cm) (79.2 cm)

SIDE

Optionalvaries. All Purifier Cell Logic+ Class II, Type A2 Biosafety Cabinets have a 9.0" working height. 		
8.0", 9.0" orworking
10.0"
Sash opening
height
(20.3, 22.9 or 25.4 cm) Scope-Ready ™
Remaining
cabinets
have
either an 8.0" or 10.0" working height depending
on the model.
Working Height
Package
25.7"
29.2"
(74.2 cm)

cm)
*Exhaust21.7"
collar(55.1
is 2.0"
high (5.0 cm).
MAX

(65.3 cm)

Class II, Type B2
C
8.8"
(22.4 cm)

17.6"
(44.7 cm)
31.2"
(79.2 cm)

Exhaust
Outlet 10.0" (25.4 cm) OD
B

A

72.6"
72.6"
(184.4 cm) (184.4 cm)
61.6"
61.6"
(156.0 cm) (156.0 cm)
Optional
Optional
8" (20 cm) 8" (20 cm)
™
Scope-Ready
™
Working Height
Working Height Scope-Ready
29.2"
21.7" (55.1 21.7"
cm) (55.1 cm) Package Package
29.2"
(74.2 cm) (74.2 cm)
MAX
MAX

TOP
	Nominal	A	
	Width

B	

C

25.7"
25.7"
(65.3 cm) (65.3 cm)

	4'	 54.3"	 48.5"	 17.2"
		(137.9 cm)	

(123.2 cm)	

(43.7 cm)

	6'	 78.3"	 72.5"	 28.9"
		

(198.9 cm)	

(184.2 cm)	

(73.4 cm)

B
A

72.6"
(184.4 cm)

B
A

FRONT

17.6"
17.6"
(44.7 cm) (44.7 cm)
31.2"
31.2"
(79.2 cm) (79.2 cm)

SIDE

61.6"
(156.0 cm)

8" (20 cm)
Select the
Pure-Vu™ Optional
Seal that’s right for you.
Scope-Ready
Working Height
™

Package
21.7" (55.1
cm)
1. To determine
placement
of the
cutouts,
MAX
measure from the centerline of the eyepieces to the base of your microscope.

Center line of
eyepiece
Nominal
eyepiece
height

14

B
A

29.2"
2. (74.2
For
inverted scopes with relatively
25.7"
cm)
cm)
stationary eyepiece height, select(65.3
a PureVu Seal corresponding with the nominal
eyepiece height in the drawing below.
All 17.6"
0.5" Dia.
(44.7 cm)
17.00"
(E)
31.2"
(D)
16.00"(79.2 cm)
15.00"
(C)
(B)
14.00"
(A)
13.00"
Dimensions shown indicate
distance from base of
microscope to centerline
of eyepiece. Blank Pure-Vu
Seal Catalog #4027800
is not shown.

Pure-Vu™ Seal

Catalog #4027817
Catalog #4027816
Catalog #4027815
Catalog #4027814
Catalog #4027813

3. For stereo scopes or inverted scopes
requiring frequent eyepiece height
adjustment, select a Pure-Vu XL Seal
(shown at right). Pure-Vu XL Seals are
designed to be pleated when installed
to allow for eyepiece height flexibility
of +/-2.0" (5 cm). The Pure-Vu XL Seals
extend 5.5" (14 cm) below the collar.

0.5" Dia.
(F) 16.00"
(+/-2.00" )
Catalog #4027811
includes hole cutouts.
Blank Pure-Vu XL
Seal Catalog
#4027810
is not shown.

4. Refer to the ordering information
on page 16 for Pure-Vu and Pure-Vu XL
Seals recommended for specific microscope models.
Pure-Vu™ XL Seal

Purifier Logic + Class II, Biosafety Cabinets
®

®

Accessories for All Models

IV Bar Kits

3402800 Vacu-Pass™ Cord &
Cable Port Kit

Include IV bar, mounting hardware and four
hangers. Installation is required.

	 Catalog #	
	 3858600	

	3858601	
	3858602	
	3858603	

For use with	
3-Ft Class II, Type A2 & B2	
4-Ft Class II, Type A2 & B2	
5-Ft Class II, Type A2 & B2	
6-Ft Class II, Type A2 & B2	

Allows passage of a cord or cable through the
right-side interior wall to the exterior. Cabinets
are factory-prepared for easy on-site installation. Includes a set of 4 closed-cell neoprene
plugs with holes for cords/cables with diameters of 1/8", 1/4", 3/8" and 1/2". Also includes
a blank plug for sealing the port during nonuse. NSF-approved port does not disrupt airflow
or cause leakage. Shipping weight 2 lbs. (1 kg)

Shipping Wt.
3 lbs. (1 kg)
4 lbs. (2 kg)
5 lbs. (2 kg)
6 lbs. (3 kg)

VACUUBRAND* BVC Basic Fluid
Aspiration Systems

3744000 Ergonomic Chair with Armrests
6-way articulating seat and back control for personalized adjustment. Pneumatic mechanism adjusts
seat height from 18.25" to 25.75" (46 x 64 cm).
Five-leg reinforced composite base with 2" (5 cm)
diameter ball-bearing casters. Aluminum support
ring. Removable armrests. Black vinyl upholstery.
Shipping weight 35 lbs. (16 kg)

Designed for connection to an external vacuum
source such as a diaphragm pump. Mechanical
vacuum controller opens when needed to limit
gas consumption from the vacuum source.
Each system includes a coated steel base, an
autoclavable collection bottle, aspiration hand
set with flow-through suction tube and PTFE
0.2 micron filter to help prevent contaminants
from entering the vacuum source. Shipping
weight 6.2 lbs. (3 kg)

3746000 Adjustable Footrest

Elevates feet and permits angle repositioning
while in use. 18.5" w x 11.5" d x 8.0" (47 x
29 x 20 cm). Shipping weight 6 lbs. (3 kg)

8022000 Logic Cart

Drawer and compartments provide convenient
storage. Top left side compartment with cutouts
and hinged panel that pivots down for loading.
High density polyethylene and ABS construction.
Overall dimensions: 25.0" w x 19.0" d x 27.0" h
(64 x 48 x 69 cm). Shipping weight 50 lbs. (23 kg)

3852000 Turntable

“Lazy Susan” rotates 360° to bring items
within easy reach. Stainless steel surface
and ball bearings. 12" (30 cm) diameter.
Autoclavable. Shipping weight 5 lbs. (2 kg)

3859100 Cord Management System

Includes three stainless steel mounting hooks and
three carabiners. The hooks mount to the rear grille
and the carabiners secure power cords and tubing
along the rear wall to keep them contained and away
from the work area. Shipping weight 3 lbs. (1 kg)

3859000 Interior Shelf

Stainless steel shelf, 8.0" x 5.0" (20 x 13 cm), mounts
to rear grille. Weight capacity: 2.2 lbs. (1 kg). Shipping
weight 3 lbs. (1 kg)

3405500 Inflow and Downflow Sensor Kit

Allows display of inflow and downflow velocities on the LCD information
center. Includes sensor, wiring harness and hardware. Not for use on Class II,
Type B2 cabinets. Installation and certifier calibration are required. Contact
Labconco about factory-installed sensors. Shipping weight 3 lbs. (1 kg)

RS 232 Connection Kits
For connecting the biosafety cabinet to a data recorder or building monitoring system. Include the PC board, cable and hardware.

	 Catalog #	
	 3858310	
	3858311	

For use with	

Shipping Wt.

Kit contains cable with 9-pin connection	1 lb. (0.5 kg)
Kit contains cable with 25-pin connection	
1 lb. (0.5 kg)

	 Catalog #	 Aspiration System includes:	 Dimensions (L x W X H)
	 3850310	 4 Liter Polypropylene Collection Bottle	
9.9 x 7.9 x 19.3"
	3850320	

2 Liter Borosilicate Glass Collection Bottle	

9.1 x 7.1 x 17.0"

VACUUBRAND* BVC Control Fluid
Aspiration Systems
Chemical-resistant PTFE diaphragm pump,
capable of drawing 12 L/minute and achieving
ultimate vacuum of 150 mBar/112 Torr, is
included. Mechanical vacuum controller opens
when needed to limit gas consumption from the
vacuum source. Each system includes a coated
steel base, adjustable suction power control via
touch panel from 150 to 850 mBar, an autoclavable collection bottle, aspiration hand set
with flow-through suction tube and PTFE 0.2
micron filter to help prevent contaminants from
entering the vacuum source. Shipping weight
17 lbs. (8 kg)
Systems with 4 Liter Polypropylene Collection Bottle
Dimensions (L x W x H): 16.1" x 7.6" x 19.7" (41 x 19 x 50 cm)
	 Catalog #	
	3850330	
	 3850331	
	 3850332	
	 3850333	
	 3850334	
	 3850335	

Electrical Requirements	
115 volts, 50/60 Hz	
230 volts, 50/60 Hz	
230 volts, 50/60 Hz	
230 volts, 50/60 Hz	
230 volts, 50/60 Hz	
230 volts, 50/60 Hz	

Plug Type
115 volts, 15 amps
North America, 230 volts
Schuko
China/Australia
British (UK)
India

Systems with 2 Liter Borosilicate Glass Collection Bottle
Dimensions (L x W x H): 16.1" x 7.6" x 16.9" (41 x 19 x 43 cm)
	 Catalog #	
	 3850340	

	3850341	
	 3850342	
	 3850343	
	 3850344	
	 3850345	
*

Electrical Requirements	
115 volts, 50/60 Hz	
230 volts, 50/60 Hz	
230 volts, 50/60 Hz	
230 volts, 50/60 Hz	
230 volts, 50/60 Hz	
230 volts, 50/60 Hz	

Plug Type
115 volts, 15 amps
North America, 230 volts
Schuko
China/Australia
British (UK)
India

VACUUBRAND® is a registered trademark of VACUUBRAND GMBH + CO KG

15

Purifier Logic + Class II Biosafety Cabinets
®

®

Accessories for All Models

3747500 Service Fixture Kit

Includes serrated hose tip valve with ball valve,
quarter turn control handle and hardware. Mounts
on left or right side interior. Cabinets are factoryprepared for up to four fixtures: two forward
mounted 8.5" above surface and two back mounted
10" above surface. Installation is required.
Shipping weight 4 lbs. (2 kg)

Ultraviolet Lamp Kits

Include 254 nm UV lamp and ballast. Not recommended for Cell Logic+
Biosafety Cabinets with Scope-Ready package. Installation is required.
	 Catalog #	
	 3858500	
	3858501	
	3858502	

For use with	

Shipping Wt.

115 Volt Class II, Type A2 & B2	
100 Volt Class II, Type A2 & B2	
230 Volt Class II, Type A2 & B2	

5 lbs. (2 kg)
5 lbs. (2 kg)
5 lbs. (2 kg)

Purifier Logic + Class II Biosafety Cabinets
®

®

A c c e s s o r i e s f o r C e l l L o g i c+ M o d e l s
Pure-Vu™ Seals

Each Cell Logic+ Biosafety Cabinet with Scope-Ready Package comes with
two clear blank membranes (one each 4027800 and one each 4027810),
which may be cut with 0.5" diameter holes or punched with Pure-Vu Punch
Kit 4027801 to fit your microscope’s eyepieces. Convenient, pre-punched
seals may be ordered separately. See instructions and drawings on page 14
for reference. Microscope examples are provided below. Please contact
Labconco for ordering assistance for seals to fit microscopes not listed.
Shipping weight 0.5 lb. (0.2 kg)
	 Reference	

Catalog #	

Nominal Eye Piece Height*	

Fits Microscope:

	 not shown	 4027800	
Universal Pure-Vu. Blank.
		 (A)	
4027813	
13.0" (33.0 cm)	
		 (B)	
4027814	
14.0" (35.6 cm)	
Zeiss† Axiovert† 40
		 (C)	
4027815	
15.0" (38.1 cm)	
Nikon† Eclipse† TS 100, 	
					
Olympus† CKX31
		 (D)	
4027816	
16.0" (40.6 cm)	
Leica† DM IL LED
		 (E)	
4027817	
17.0" (43.2 cm)	
Leica† DM 6000 B
		
not shown	 4027810	
Universal Pure-Vu XL. Blank.
		 (F)	
4027811	
16.0" (+/-2.0") 	
Leica† MZ95
				
(40.6 cm, +/- 5.1 cm)	
Nikon† SMZ 1500	
					
Olympus† SZX 16

Stand-Still™ Isolation Platforms

Required for supporting microscopes on Cell Logic Biosafety Cabinets
with Scope-Ready™ package. Designed to promote proper airflow through the
cabinet. Reduces vertical and horizontal vibrations threefold. Constructed of
seamless, non-porous, autoclavable Type 304 stainless steel base with isolation
pads. 1.5" high (0.4 cm). Select the platform that best fits your microscope’s
dimensions.
	Catalog #	
Description	
Shipping Wt.
	 4028200	 Stand-Still Platform, 12.0 x 18.75" (30.5 x 47.6 cm)	8 lbs. (4 kg)
	4028100**	 Stand-Still XL Platform, 14.0 x 22.75" (35.6 x 57.8 cm) 	 10 lbs. (5 kg)

**Requires use of Pure-Vu XL Seal 4027810 or 4027811.

Universal Tube Baths

Blue anodized aluminum blocks hold tubes
of various sizes in an aluminum bead bath.
Aluminum promotes the conduction of heat or
cold from the Temp-Zone™ area to help maintain sample temperature. Thermally-conductive
beads are sold separately.

* 	When selecting a seal for a Cell Logic+ Class II, Type B2 Biosafety Cabinet, add one inch to your 	
		eyepiece height and use the chart above.
† 	Zeiss® and Axiovert® are registered trademarks Carl-Zeiss-Stiftung DBA Carl Zeiss Corporation.
	
	Nikon® and Eclipse® are registered trademarks of Nikon, Inc. Olympus® is a registered trademark 	
®
	 of O
	 lympus Corporation. Leica is a registered trademark of Leica Technology.

4027801 Pure-Vu™ Punch Kit

For punching accurate eyepiece holes in blank Pure-Vu seals. Includes
1/2" (12.7 mm) diameter hole punch, cutting pad and instructions.
Shipping weight 1 lb. (0.5 kg)

	 Catalog #	

Aluminum
Tube Racks

Blue anodized aluminum
blocks hold tubes upright
and promote conduction
of heat or cold from the
Temp-Zone™ area to help
maintain sample
temperature.
16

Tube Size/Description	

	Catalog #	
	 4026600	

Description	

Shipping Wt.

Small Bath, 0.25 L capacity	
		
2.0" w x 4.0" d x 3.0" h (50.8 x 101.6 x 76.2 mm)
	4026601	
Large Bath, 0.5 L capacity	
		
4.0" w x 4.0" d x 3.0" h (101.6 x 101.6 x 76.2 mm)
	4026602	
Lab Armor†† Beads, 0.75 liter	
Tube Capacity	

	 4026400	
0.5 ml microcentrifuge, 7.5 mm	
	4026401	
0.5 ml microcentrifuge, 7.5 mm	
	 4026402	
1.5 ml microcentrifuge, 10.5 mm	
	 4026403	
1.5 ml microcentrifuge, 10.5 mm	
	 4026404	
1.5 ml flat bottom, 10 mm	
	 4026405	
5 ml flat bottom, 12 mm	
	 4026406	
6 ml flat bottom, 13 mm	
	 4026407	
15 ml round, 16-17 mm	
	 4026408	
15 ml conical, 16-17 mm	
	 4026409	
50 ml round, 28 mm	
	 4026410	
50 ml conical, 28 mm	
	 4026411	 microtiter well plate, 3.4" x 5.0" (86 x 127 mm)	
		
1.5 ml microcentrifuge	
		
0.5 ml microcentrifuge	

Dimensions (w x d x h)	

2 lbs. (1 kg)
2 lbs. (1 kg)
5 lbs. (2 kg)

Shipping Weight

18	
1.5 x 6.0 x 1.3" (38 x 152 x 32 mm)	
2 lbs. (1 kg)
96	
6.0 x 8.0 x 1.5" (152 x 203 x 38 mm)	
8 lbs. (3 kg)
18	
2.0 x 6.0 x 1.5" (51 x 152 x 38 mm)	
2 lbs. (1 kg)
96	
8.0 x 8.0 x 1.5" (203 x 203 x 38 mm)	
9 lbs. (4 kg)
12	
1.5 x 4.0 x 1.3" (38 x 102 x 32 mm)	
1 lb. (0.5 kg)
12	
2.0 x 5.0 x 2.5" (51 x 127 x 64 mm)	
3 lbs. (1 kg)
12	
2.0 x 5.0 x 2.5" (51 x 127 x 64 mm)	
3 lbs. (1 kg)
12	
2.0 x 6.0 x 3.0" (51 x 152 x 76 mm)	
4 lbs. (2 kg)
12	
2.0 x 6.0 x 4.0" (51 x 152 x 102 mm)	
5 lbs. (2 kg)
4	
1.5 x 6.0 x 4.0" (38 x 152 x 102 mm)	
3 lbs. (1 kg)
4	
1.5 x 6.0 x 4.0" (38 x 152 x 102 mm)	
3 lbs. (1 kg)
1	
6.0 x 8.0 x 1.5" (152 x 203 x 38 mm)	
5 lbs. (2 kg)
12	
12			

Purifier Logic + Class II Biosafety Cabinets
®

®

Filters, Ductwork & Blowers

Screen Prefilter Starter Kits

3858800 Backdraft Damper

Mounts in vertical duct run to prevent reverse
pressurization of the exhaust system. 3.0"
(8 cm) high with 10" (25.4 cm) diameter OD
inlet and outlet. Shipping weight 5 lbs. (2 kg)

Each kit consists of a washable/reusable, metal screen-type prefilter
and hardware including bracket for installing on the towel catch.
Installation is required.
	 Catalog #	
	 3406100	
	3406101	
	3406102	
	3406103	

For use with	

Shipping Wt.

3-Ft Biosafety Cabinet	
4-Ft Biosafety Cabinet	
5-Ft Biosafety Cabinet	
6-Ft Biosafety Cabinet	

4 lbs. (2 kg)
5 lbs. (2 kg)
6 lbs. (3 kg)
7 lbs. (3 kg)

G4 Prefilter Starter Kits & Replacement Prefilters

Pleated disposable filter with Merv 8 rating. Kits include prefilter,
hardware and bracket for installing on the towel catch. Installation
is required.
	 Kit Catalog #	

Repl. Prefilter Catalog #	

For use with

3406200	
3406201	
3406202	
3406203	

3-Ft Biosafety Cabinet
4-Ft Biosafety Cabinet
5-Ft Biosafety Cabinet
6-Ft Biosafety Cabinet	

	 3406000	
	3406001	
	3406002	
	3406003	

Flexible Hose Kits

For connection between the Ventus™ and exhaust ductwork.
10" nominal diameter. Include spiral flexible tubing and clamps.
	 Catalog #	

Hose Length	

Shipping Wt.

	 7034200	

1' (30.5 cm)	
3' (91.4 cm)	
6' (182.9 cm)	
10' (304.8 cm)	

2 lbs. (1 kg)
5 lbs. (2 kg)
10 lbs. (5 kg)
20 lbs. (9 kg)

	7034201	
	7034202	
	7034203	

Typical Class II
Cabinet Exhaust System
Zero Pressure Weathercap
7095100, 10" dia.
5622100, 12" dia.

Ventus™
Canopy Connection

For thimble ducting Class II, Type A2
Biosafety Cabinets. Canopy provides an
air gap to allow room air to enter the
ductwork and mix with the filtered air
being exhausted to the outside. Inadequate exhaust activates the switch in
less than one second and signals the LCD to display an alarm and the motor
to increase to maximum speed for personal safety. Adds only 1.25" to the
overall height of the cabinet. Powder-coated steel. Outlet is 10" (25.4 cm) ID.
Exhaust connection is required. Damper 3776800 and Remote Blower
7068000 or 7068200 are recommended (not included). Contact Labconco
for information on factory installation. Shipping weight 15 lbs. (7 kg)
	 Catalog #	
For use with	
			

Total Exhaust Volume
(Safety Cabinet and Room Air)

			

8" Sash Opening	 9" Sash Opening	 10" Sash Opening

	 3889200	
	3889201	
	3889202	
	3889203	

3-Ft Class II, Type A2	
4-Ft Class II, Type A2	
5-Ft Class II, Type A2	
6-Ft Class II, Type A2	

223-353	
289-369	
356-470	
423-543	

248-351	
324-433	
398-516	
473-598	

Duct Reducer
5606100, 10" x 12" dia.
Flexible Duct Connection
7034200, 11" dia.

90° Elbow
7027300, 10" dia.

Male Duct
Coupling 12" dia.
7067300

Air-Tight
Damper
(included with
Type B2 and
accessory for
Canopy-ducted
Type A2)

273-379
359-470
440-562
523-654

Remote Blowers

Required for Type B2 cabinets and recommended
for canopy-ducted Type A2 cabinets. Phenolic-coated
impeller and housing, powder-coated steel base and
weather cover, belt-drive motor with adjustable sheave
and self-adjusting gravity belt tightener. Contact
Labconco for dimensions and blowers of other sizes
and electrical configurations.

Blower
Transition
Adapter,
4722401,
10" dia.
7003400,
12" dia.
Remote
Blower

Thermoplastic Duct
7027200, 10" dia.
Canopy
Connection
(Type A2 only)
or Sealed
Connection
(Type B2 only)

3776800 Air-Tight Damper

Mounts atop the Canopy Connection to adjust exhaust
airflow and closes for decontamination procedures.
Manually adjustable. Type 304 stainless steel. 10"
(25.4 cm) high with 10" (25.4 cm) diameter OD inlet and
outlet. Shipping weight 13 lbs. (6 kg)

Backdraft
Damper
3858800,
10" dia.

Thermoplastic Duct
7027200, 10" dia.
5602000, 12" dia.

Contact Labconco at 800-821-5525 or 816-333-8811 for ordering information and
technical assistance in selecting the right ductwork for your installation.

		
	 Inlet	
	Outlet	
	Blower	
	 Transition	
	Adapter
	Required

7068000 & 7068200	

7071900

10.87" (27.6 cm) ID	
5.5" d x 10.0" w (14 x 25 cm)	

12.25" (31.1 cm) OD
7.0" x 13.5" (18 x 34 cm)

4722401	

7003400

	 Catalog #	

For use with	

Electrical Requirements	

HP	

CFM Range†	

Shipping Weight

	 7068000	

3-Ft & 4-Ft Type A2 Cabinets	
5-Ft & 6-Ft Type A2 Cabinets	
4-Ft & 6-Ft Type B2 Cabinets	

115 volts, 60 Hz, 1 phase, 4.0 amps	
115 volts, 60 Hz, 1 phase, 4.4 amps	
230/460 volts, 60 Hz, 3 phase, 5.8/2.9 amps	

1/6	
1/4	
2	

370 @ .12" to 410 @ .38"	
540 @ .25" to 430 @ .75"	
977 @ 3.4" to 1161 @ 4.7"	

92 lbs. (42 kg)
92 lbs. (42 kg)
100 lbs. (45 kg)

	7068200	
	7071900	
†

Air volume at static pressure in inches H2O

17

Purifier Logic + Class II Biosafety Cabinets
®

®

Telescoping Base Stands (Non-Welded)

These stands have telescoping legs so that they may be adjusted to
eight height positions.*

Standard Features
•	NSF-approved. Meet NSF Standard for stability and construction.
•	Support Purifier Logic Biosafety Cabinets.
•	Support loads up to 1000 pounds.
•	ADA-compliant.
•	Durable 1.75" tubular, powder-coated steel frame with back 	
panel support.

•	Telescoping legs are adjustable to eight height positions at
installation in 1" (2.5 cm) increments to provide a working
height from 30" (76 cm) to 37" (94 cm).*

Telescoping Base Stand (non-welded) 3401004

•	9" (23 cm) shelf is included.

Telescoping Base Stands (non-welded)

•	Four fixed leveling feet are provided.

	

Nominal Width	

Catalog #	

Shipping Weight

•	Unassembled. May be easily assembled with simple hand tools.

	

3-Ft	

3401003	

117 lbs. (53 kg)

*	Height selection and adjustment are required before the enclosure is installed
	 on the stand.

	4-Ft	

3401004	

125 lbs. (57 kg)

	5-Ft	

3401005	

133 lbs. (60 kg)

	 Catalog #	

Nominal Width	

A	

	6-Ft	

3401006	

149 lbs. (68 kg)

	3401003	

3-Ft	

38.5" (97.8 cm)

	3401004	

4-Ft	

50.5" (128.3 cm)

	3401005	

5-Ft	

62.5" (158.8 cm)

	3401006	

6-Ft	

74.5" (189.2 cm)

A

27.5"
(69.9 cm)
min.
34.5"
(87.6 cm)
max.

**	Enclosures supported by mobile Base Stands will require special modifications to incorporate 	
	 flexible ducting, wiring and plumbing when applied.
Comply with height and knee clearance guidelines outlined in ADA Standards for Accessible Design.

3730500 Caster Kit
For converting Telescoping Base
Stands with Fixed Feet to mobile
stands. Kit includes four 5" diam29.0" (73.7 cm)
eter, non-marking polyurethane
1.8" (4.6 cm)
11.8" (30.1 cm)
casters with toe locks. Load rating for each caster is 250 pounds. Casters have
bearings for quiet operation. Casters replace the fixed feet included with
Telescoping Base Stands. Casters add 11" (28 cm) to the overall depth of the
Crossbar
base stand. Installation is required. Not for use with stands that support
Purifier Logic Class II, Type B2 Safety Cabinets. Shipping weight 10 lbs. (5 kg)
9.1"
(22.9 cm)

3857000 Seismic Bracket Kit
For securing the Telescoping Base Stand to the floor
in earthquake-prone regions. Includes four stainless
steel seismic brackets and hardware for attachment
to the stand. Hardware to attach to the floor and
installation are required. Shipping weight 10 lbs.
(5 kg)

Shelf

FRONT

29.0" (73.7 cm)
1.8" (4.6 cm)

27.5"
(69.9 cm)
min.
34.5"
(87.6 cm)
max.

Crossbar
9.1"
(22.9 cm)

Shelf

SIDE
18

Laptop Computer Arms

11.8" (30.1 cm)

Contact Labconco for ordering information on welded telescoping base stands.

Securely support a laptop computer
within easy view of an operator at
the Cell Logic+. Mount to front leg
of front leg of Telescoping Base
Stands or front of SoLo Base Stands
(see back cover). Articulating arm
raises, lowers and pivots to a
steady position. Include powder-coated steel arm and support surface with
cloth loop fasteners and mounting hardware. Not for use with other
Hydraulic Lift Base Stands. Installation is required.
	 Catalog #	

For use with	

Shipping

	 3869300	
Telescoping Base Stand	12 lbs. (5 kg)
	3869200	Solo Hydraulic Lift Base Stand	
12 lbs. (5 kg)

Purifier Logic + Class II Biosafety Cabinets
®

®

Hydraulic Lift Base Stands

These stands have a built-in hydraulic lift so that height may be
adjusted at any time. They allow the user to position the stand
and the safety cabinet it supports to accommodate persons
of different heights and wheelchair-bound users, to transport
equipment through doorways, and for easier access to services.

Standard Features
•	Meet NSF Standard for stability and construction.
•	Support Purifier Logic Biosafety Cabinets.
•	Support loads up to 1000 pounds.
•	ADA-compliant.
•	Durable 1.75" (4.4 cm) tubular, epoxy-coated steel frame with rear
crossbar supports. Sub-frame has 2.0" (5.1 cm) x 3.0" (7.6 cm)
rectangular tubing.

•	Height is infinitely adjustable from 25.5" (64.8 cm) to

Hydraulic Lift Base Stand 3780201.

	

33.5" (85.1 cm) high.

•	Include four powder-coated, die-cast feet with levelers.
•	Include front-accessible up/down switch (Electric Lift models)
•	Include front-accessible hand crank. Turning the crank clockwise raises the stand; counterclockwise lowers it. The handle
may be disengaged and folded under, out of the way, when
not in use. (Manual Lift models)

•	Shipped fully assembled.
	

Catalog Numbers	

Nominal Width	

	 3780100, 3780103, 3780200	
	 3780101, 3780104, 3780201	
	 3780106, 3780107, 3780203	
	 3780102, 3780105, 3780202	

3-Ft	
4-Ft	
5-Ft	
6-Ft	

A	

B

38.5"	39.7"
50.5"	51.7"
62.5"	63.9"
74.5"	75.7"

	Nominal			
	 Width	 Catalog #	 Description	
	 3-Ft	 3780100	
	3-Ft	 3780103†	

Electric. 115 volts, 60 Hz, 2.4 amps	

Electric. 230 volts, 50/60 Hz, 0.8 amp	
	3-Ft	 3780200	 Manual	
	4-Ft	 3780101	 Electric. 115 volts, 60 Hz, 2.4 amps	
	4-Ft	 3780104†	 Electric. 230 volts, 50/60 Hz, 0.8 amp	
	4-Ft	 3780201	 Manual	
	5-Ft	 3780106	 Electric. 115 volts, 60 Hz, 2.4 amps	
	5-Ft	 3780107†	 Electric. 230 volts, 50/60 Hz, 0.8 amp	
	5-Ft	 3780203	 Manual	
	6-Ft	 3780102	 Electric. 115 volts, 60 Hz, 2.4 amps	
	6-Ft	 3780105†	 Electric. 230 volts, 50/60 Hz, 0.8 amp	
	6-Ft	 3780202	 Manual	

Up/Down Switch
A

29.0"

9.5"
16.0"

B

34.3"

FRONT
FRONT

SIDE
SIDE

MANUAL
LIFT
Manual
Lift

Includes four 5" (13 cm)
diameter, non-marking
polyurethane casters with
toe locks and bearings.
Load rating for each caster is 250 pounds. Casters replace the fixed feet and
add 11" (28 cm) to the overall depth of the base stand. Installation is
required.** Not for use with stands that support Type B2 Safety Cabinets.
Shipping weight 10 lbs. (5 kg)

4028600 Support Shelf

Provide a work surface to support remote
equipment. Powder-coated steel shelf mounts to
left-side tubular frame of base stand. 12.0" w x
22.0" deep (26 x 30 cm). Installation is required.
Shipping weight 23 lbs. (10 kg)

Hand Crank
A

7.4"

170 lbs. (77 kg)
170 lbs. (77 kg)
170 lbs. (77 kg)
185 lbs. (84 kg)
185 lbs. (84 kg)
185 lbs. (84 kg)
215 lbs. (98 kg)
215 lbs. (98 kg)
215 lbs. (98 kg)
225 lbs. (102 kg)
225 lbs. (102 kg)
225 lbs. (102 kg)

Caster Kit
3784000

ELECTRIC
Electric
LiftLIFT

25.5" min.
33.5" max.

Shipping
Weight

29.0"

4.4"

25.5" min.
33.5" max.

**	Enclosures supported by mobile Base Stands will require special modifications to incorporate 	
	 flexible ducting, wiring and plumbing when applied.
B

34.3"

FRONT
FRONT

SIDE
SIDE

†		International

electrical configuration

Complies with Americans with Disabilities Act Standard for height of controls and receptacles

19

Purifier Logic + Class II Biosafety Cabinets
®

®

S o l o™ B a s e S t a n d s

SoLo™ Hydraulic Lift Base Stands are specifically designed to
support Purifier Logic+ and Cell Logic+ Class II, Type A2 Biosafety
Cabinets. The hydraulic lift system permits the stand to be lowered
allowing the safety cabinet to be rolled through standard doorways
as low as 78" (198 cm) high. Casters provide mobility and lock in
place for stability.

Standard Features
•	Meet NSF Standard for stability and construction.
•	Support any Purifier Logic+ or Cell Logic+ Class II, 		
Type A2 Safety Cabinet.

•	ADA-compliant.
•	Durable powder-coated steel construction.
•	Support loads up to 1300 pounds (590 kg).
•	Built-in hydraulic lift is operated by a remote control with 	

SoLo Hydraulic Lift Base Stand 3780311.

buttons for upward and downward movement. Height adjustment positions the enclosure for persons of different statures,
wheel-chair bound users, transport through doorways, and 	
easier service access to upper components.

A

•	Infinitely adjustable height provides work surface heights from 	

17.2" (43.7 cm) to 36.8" (93.5 cm) and overall enclosure height 	
as low as 76.2" (193.5 cm).

39.9"
MIN
59.5"
MAX

•	5" (13 cm) diameter, toe-locking, non-marking polyurethane
casters with bearings for quiet operation.

•	Two handle bars on each side facilitate transport. Bars are
durable PVC-coated steel tubes with polyamide brackets.

	

•	Accommodate Laptop Computer Arm 3869200, sold separately.

14.0"
MIN
33.6"
MAX

See page 18.

•	Shipped fully assembled.
	 Nominal	
	 Width	

Actual		
Width (A)	 Catalog #	

	 3-Ft.	53.5"	
3780310	
	3-Ft.	 53.5"	 3780314	
	3-Ft.	 53.5"	 3780330	
	3-Ft.	 53.5"	 3780334	
	3-Ft.	 53.5"	 3780338	
	4-Ft.	 65.5"	 3780311	
	4-Ft.	 65.5"	 3780315	
	4-Ft.	 65.5"	 3780331	
	4-Ft.	 65.5"	 3780335	
	4-Ft.	 65.5"	 3780339	
	 5-Ft.	
77.5"	
3780312	
	5-Ft.	 77.5"	 3780316	
	5-Ft.	 77.5"	 3780332	
	5-Ft.	 77.5"	 3780336†	
	5-Ft.	 77.5"	 3780340	
	6-Ft.	 89.5"	 3780313	
	6-Ft.	 89.5"	 3780317	
	6-Ft.	 89.5"	 3780333	
	6-Ft.	 89.5"	 3780337	
	6-Ft.	 89.5"	 3780341	
	

34.3"

Electrical 	
Requirements	

Plug	
Type	

Additional	
Load Capacity*	

Shipping	
Weight

115 volts, 60 Hz, 2 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
115 volts, 60 Hz, 2 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
115 volts, 60 Hz, 2 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
115 volts, 60 Hz, 2 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	
230 volts, 50/60 Hz, 3 amps	

115 volts, 15 amps	
North America, 230 volts	
British (UK), 230 volts	
Schuko, 230 volts	
China/Australia, 230 volts	
115 volts, 15 amps	
North America, 230 volts	
British (UK), 230 volts	
Schuko, 230 volts	
China/Australia, 230 volts	
115 volts, 15 amps 	
North America, 230 volts	
British (UK), 230 volts	
Schuko, 230 volts	
China/Australia, 230 volts	
115 volts, 15 amps	
North America, 230 volts	
British (UK), 230 volts	
Schuko, 230 volts	
China/Australia, 230 volts	

700 lbs. (318 kg)	
700 lbs. (318 kg)	
700 lbs. (318 kg)	
700 lbs. (318 kg)	
700 lbs. (318 kg)	
600 lbs. (272 kg)	
600 lbs. (272 kg)	
600 lbs. (272 kg)	
600 lbs. (272 kg)	
600 lbs. (272 kg)	
500 lbs. (227 kg)	
500 lbs. (227 kg)	
500 lbs. (227 kg)	
500 lbs. (227 kg)	
500 lbs. (227 kg)	
350 lbs. (159 kg)	
350 lbs. (159 kg)	
350 lbs. (159 kg)	
350 lbs. (159 kg)	
350 lbs. (159 kg)	

395 lbs. (179 kg)
395 lbs. (179 kg)
395 lbs. (179 kg)
395 lbs. (179 kg)
395 lbs. (179 kg)
435 lbs. (197 kg)
435 lbs. (197 kg)
435 lbs. (197 kg)
435 lbs. (197 kg)	
435 lbs. (197 kg)		
460 lbs. (209 kg)
460 lbs. (209 kg)
460 lbs. (209 kg)
460 lbs. (209 kg)	
460 lbs. (209 kg)
600 lbs. (272 kg)
600 lbs. (272 kg)	
600 lbs. (272 kg)
600 lbs. (272 kg)
600 lbs. (272 kg)		

Labconco Corporation
8811 Prospect Avenue • Kansas City, MO 64132-2696
816-333-8811 or 800-821-5525 • FAX: 816-363-0130
E-MAIL: labconco@labconco.com • HOME PAGE: www.labconco.com

© 2013 by Labconco Corporation  •  Printed in the U.S.A.
Product design subject to change without notice  •  2-04-GC-3/13-4M-R1



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2013:03:14 15:17:52-05:00
Creator                         : Adobe InDesign CS6 (Macintosh)
Modify Date                     : 2014:06:25 15:28:09-07:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:06:25 15:28:09-07:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:c8fa5357-5299-40e5-9723-bab87404042a
Original Document ID            : xmp.did:F77F1174072068118C14A5B63BB16E0C
Document ID                     : xmp.id:9FDDEE7D2A2068118083E16EA7BAB9BB
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:9EDDEE7D2A2068118083E16EA7BAB9BB
Derived From Document ID        : xmp.did:9EDDEE7D2A2068118083E16EA7BAB9BB
Derived From Original Document ID: xmp.did:F77F1174072068118C14A5B63BB16E0C
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2013:03:14 15:17:52-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 20
EXIF Metadata provided by EXIF.tools

Navigation menu