Purifier® Logic®+ Class II Biosafety Cabinets Purifier Logic + Class II Biosafety Cabinets ® ® Designed for the HUMAN Experience The good news is that most biological safety cabinet Performance manufacturers build their cabinets to NSF* International protection having an open front with inward airflow for personnel Nothing enhances the human experience more than a biosafety cabinet that allows you to work confidently and with peace of mind. Unique to the Purifier Logic+ Biosafety Cabinet is its built-in intelligence to accurately maintain proper airflow, even as the HEPA filters load. Accuracy is achieved with an Electronically Commutated Motor (ECM) coupled with Labconco’s exclusive Constant Airflow Profile™ (CAP) Technology. protection, downward HEPA filtered laminar airflow for product protec- The benefits of ECM: tion, and HEPA filtered exhaust air for environmental protection.” • Energy efficiency (see Table 1). The ECM consumes 60% less specifications and have NSF listing. Biosafety cabinets, by their NSF definition, are designed to be safe: “A ventilated cabinet for personnel, product, and environmental The news gets better. Labconco has added features to its newest energy than conventional motors. • Comfortable working temperature. The ECM generates less heat generation of Purifier Logic+ Biosafety Cabinets that resets the bar for not than conventional motors for cooler working conditions. only safety but also comfort. Unlike • Quiet (< 63 dBA). The ECM operates as much as 50% quieter than conventional motors. other cabinets, the Purifier Logic+ was designed for the human body and • Reliable. The time-tested ECM has a long life (50,000 hour average motor life) and reliable operation. habits that goes beyond ergonomics. We call it Inclination™ Technology— design that caters to human behavior. • More power for longer lasting filters. Because it has greater torque than conventional motors, the ECM overcomes more resistance as HEPA filters load so filters last longer. You experience less fatigue, fewer distractions and a more comfortable working environment. Your work demands precision, attention to details and constant vigilance to safe practices. We believe the more comfortable you are, the safer you will be. For total comfort, effortless operation and maximum safety, the Purifier Logic+ Biosafety Cabinet is your logical choice. Read more about the difference a human-designed biosafety cabinet makes. • Performance of Constant Airflow Profile™ • • Safety of MyLogic™ Comfort of Inclination™ Technology * NSF® is a registered trademark of NSF International, Ann Arbor, MI. Purifier Logic + Class II Biosafety Cabinets ® ® Designed for the HUMAN Experience Constant Airflow Profile™ (CAP) Technology is built-in intelligence that works with the ECM to precisely control airflow without the need for airflow sensors. During operation, the ECM is constantly adjusting its speed and torque to accurately maintain its programmed airflow. Tests confirm that airflow is maintained within 1%. Using CAP Technology to monitor and provide accurate airflow has advantages over relying on differential pressure gauges or airflow sensors. Biosafety cabinets that solely rely on pressure gauges require manual adjustment by a certifier when readings indicate a decline in airflow performance. Likewise, airflow sensors have a known standard of deviation exceeding safe airflow requirements in Class II cabinets. A certifier can verify safe airflow for a single moment in time. CAP Technology maintains safe airflow all the time. Sustainable Design As a member of the U.S. Green Building Council (USGBC), Labconco is committed to designing environmentally-responsible products. The Logic+ is one example. Since Logic+ uses less energy and lowers the heat load compared to cabinets with conventional motors, it contributes toward satisfying EA Credit 1 under LEED. New construction buildings with the Logic+ cabinets installed can earn from one to 19 LEED points for energy use reduction. The 8.5% pre-consumer and 54.5% post-consumer recycled content of the Logic+ can contribute towards satisfying MR Credit 4. Buildings that incorporate recycled materials may be awarded from one to two LEED points. When it is time to remove a Logic+ from service, its recyclable content is 94.9%, another measure of its contribution toward preserving our environment. Performance Features & Benefits: • Reliable ECM provides energy-efficient operation. • CAP Technology assures consistent delivery of precise air volume, even as filters load. No sensors are needed. • Low lifetime cost (see Table 1). Energy efficiency and lower maintenance costs add up to a lower total lifetime cost. • Air-Wave™ Entry System, consisting of aerodynamic angles surrounding the access opening, provides less airflow resis- tance for better containment. • Contain-Air™ Negative Pressure Channel draws air in, preventing loss of containment at the top of the sash. • Smart-Start™ System automates routine start up and shut down functions, assuring consistent operation regardless of the user and saves time. • Night-Smart™ System idles the blower at 30% speed when the sash is fully closed to help maintain a clean environment inside the cabinet during periods of non-use while saving energy. When the sash is raised, the blower automatically resumes normal operation. • 5 year warranty * LEED® is a registered trademark owned by the U.S. Green Building Council and is used with permission. Table 1. 4' Purifier Logic+ Biosafety Cabinet Energy Usage and Operating Costs & Comparison Logic+ Other Cabinet A Other Cabinet B Motor Type/Technology DC ECM AC PSC AC-3Ø 8 hrs/day (2,080 hrs/year)* Energy Used (kWh/yr) 603 1206 861 Annual Cost - Commercial $60 $121 $86 Annual Cost - Industrial $41 $81 $58 24 hrs/day (8,736 hrs/year)* Energy Used (kWh/yr) 2533 (803**) 5067 3617 Annual Cost - Commercial $253 ($80**) $507 $362 Annual Cost - Industrial $170 ($54**) $341 $243 15-Year Life Cycle Costs† Operational Costs Annual Certification $2,250 $2,250 $2,250 Energy Cost - 8 hrs/day (Industrial) $609 $1,217 $869 Energy Cost - 24 hrs/day (Industrial) $2,557 ($811**) $5,115 $3,651 Total Operational Cost (8 hr/day) $2,859 $3,467 $3,119 Total Operational Cost (24 hr/day) $4,807 ($3,061**) $7,365 $5,901 Maintenance Costs HEPA Filter Costs $800 $1,600 $1,600 Service Cost $3,000 $3,450 $3,450 Replacement Parts $700 $1,100 $1,100 Total Maintenance Cost $2,250 $3,900 $3,900 Total Lifetime Cost (8 hr/day) $5,109 $7,367 $7,019 Total Lifetime Cost (24 hr/day) $7,057 ($5,311**) $11,265 $9,801 †† Other Cabinet C DC 339 $34 $23 1424 $142 $96 $2,250 $342 $1,438 $2,592 $3,688 $2,400 $4,350 $2,500 $7,000 $9,592 $10,688 * Using a Commercial Business Energy use cost of $0.0988/kWh and an Industrial Energy use cost of $0.0673/kWh. ** Continuous operation of cabinet utilizing Night-Smart™ reduced flow setback mode. Calculations based on using Night-Smart™ idle setback 16hr/day for 5 days/wk and 24 hr/day for 2 days/week, 52 week calendar year. † Costs of HEPA filters, service and replacement parts are approximations, not an estimate or guarantee of any kind. †† Service cost includes annual certification ($150/yr), decontamination ($450/incident), and incidentals. 3 Purifier Logic + Class II Biosafety Cabinets ® ® Designed for the HUMAN Experience Safety The most important reason to choose the Purifier Logic+ is safety. You simply won’t find another biosafety cabinet with a more comprehensive safety package than the Logic+. Purifier Logic+ Biosafety Cabinets meet or exceed all minimum requirements set by NSF International including 99.99% efficient HEPA filters and nominal inflow of 105 fpm. The Logic+ goes well beyond the NSF Standard by providing the user with peace of mind that airflow is within normal limits and the HEPA filters are working properly. A full color, line-of-sight LCD information center, which is in constant communication with the ECM, continuously monitors and displays the cabinet’s performance. The benefits of the LCD information center: Various alert and alarm messages may be displayed and provide clear feedback and instruction. • Easy readability with MyLogic™ OS. The large full color display runs on MyLogic™ OS that provides user-friendly programming and feedback. Mounted on the interior right side wall of the user’s line of sight while seated, the display shows cabinet function, filter loading and systems in use. • Descriptive feedback in easy-to-understand full sentences leaves nothing to interpretation. Step-by-step instruction guides you when programming features such as Smart-Start and Night-Smart. • “Filter Remaining” bar graph. A bar graph depicts percent of HEPA filter life remaining to provide assurance and allow you to accurately and confidently plan for future filter replacement. Alerts warn when the filter life diminishes to 20% and 0%. • Alerts and Alarms. Visual and audible alarms warn users of cabinet errors, explain the meaning of the alarm, diagram where the cabinet has been affected, and provide intuitive trouble- shooting tips. Safety Features & Benefits: • Line-of-sight Information Center with MyLogic™ OS provides at-a-glance assurance that your cabinet is operating safely. • Fully-closing, tempered safety glass sash. An audible/ visual alarm indicates when the sash is opened above its working height. • Reserve-Air™ Inflow Slots on the inlet grille draw air into the cabinet to maintain safe airflow should the user inad- vertently block portions of the grille while resting arms. • NSF-approved Vacu-Pass™ Cord & Cable Portal, avail- • Durable construction. The display is constructed of UV-opaque able on some models, safely allows passage of electrical cords and tubing through the side of the cabinet without air leakage or airflow disruption. See page 9 for more information. safety glass and stainless steel for easy decontamination. • Electronic security lock, when enabled, prevents operation of the cabinet by unauthorized users. • NSF listed* Bar graph displays percent of HEPA filter life remaining 4 * Applies to Purifier Logic+ Class II, Type A2 and B2 Biosafety Cabinets Purifier Logic + Class II Biosafety Cabinets ® ® Designed for the HUMAN Experience Inclination Technology has been applied throughout the cabinet. While seated, the LCD information center is within sight and the touchpad controls are within reach. Greater comfort lessens the risk of accidents and personal injury. Comfort Labconco’s Inclination™ Technology—features that reinforce what humans are inclined to do—is nothing new to us. We’ve been at the forefront of designing ergonomics and comfort features into our biosafety cabinets for decades. For example, in 1983, we pioneered the use of an angled sash, which allows closer, more comfortable viewing without glare. We thoughtfully design every feature to ensure that form follows function and the shape of the human body. The curved inlet grille provides a comfortable surface for forearms resting on it. No additional armrest is needed. Reserve-Air ™ Inflow Slots draw air into the cabinet should the operator inadvertently block portions of the inlet grille, maintaining safe airflow. Unobtrusive lift knobs on the front corners of the dished stainless steel work surface allow it to be quickly lifted for cleaning. The electrical outlet cover may be opened with one finger and then gently and slowly self closes. It mounts flush and flat against the side wall for easy cleaning. Scan this code to view a brief video showing some of the Inclination Technology features in action. 5 Purifier Logic + Class II Biosafety Cabinets ® ® Designed for the HUMAN Experience Comfort Features & Benefits: 25.6 " • ECM is quieter and cooler than comparable PSC motors. • Line-of-sight, full color LCD information center is visible 21" to the user while seated at the cabinet. • ADA-compliant, easy-to-clean touchpad controls allow manual activation of blower, timer, audible alarm mute and menu selection. 10" Sash 8" Sash • ADA-compliant service fixtures, available factory- or 8" 10" Worktop Ht. 35" user-installed, are mounted within easy reach on the side walls, 8.5" (20 cm) above the work surface to maximize usable surface area, permit free arm movement and allow easy removal of the work surface. See page 9 for more information. • Curved inlet grille gently supports the user’s forearms without the need for uncomfortable, hard-to-clean armrests. 32.5" • Flush-mounted electrical duplex covers have dampened hinges that close slowly rather than snapping shut on fingers. Surfaces are easy-to-clean stainless steel. 6" • Counterweighted sliding sash with anti-racking mechanism may be raised and lowered with minimal effort. • Large interior work area offers more cubic feet than any other brand. • Inclined sash is sloped at 10° for closer, more comfortable viewing than vertical sashes offer. Two small, sculptured sash handles on the outside surface of the sash do not obstruct the view of the interior. 24.6" 19" • Over 27" (69 cm) of viewing height gives greater visual accessibility. • Bright, glare-free fluorescent lighting with timer pro- vides 90-100 footcandles at the work surface, exceeding NSF requirements. 10" Sash 8" Sash 8" 10" Worktop Ht. 33" 8" 30.5" 6" 6 Ergonomic principles were applied to the design of the Purifier Logic+ Biosafety Cabinet to ensure that humans of all sizes maintain a healthy posture, and have good visibility and range of motion while using the cabinet. The illustrations above show an adult male of an average height of 5' 9.1" and an adult female of an average height of 5' 3". The accessory base stand, chair and footrest work together to achieve the proper height for individuals using the cabinet. Purifier Logic + Class II Biosafety Cabinets ® ® Type A2 & B2 — Which do you Choose? Select the right Purifier Logic Biosafety Cabinet for your application Purifier Logic+ Class II Biosafety Cabinets come in Type A2 and Type B2 configurations. The airflow diagrams below illustrate the differences between the two Types. Which configuration you choose is determined by your application. Both Type A2 and B2 cabinets are suitable for work with agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antioneoplastic drugs, genetic material, carcinogens, allergens and additional substances that generate hazardous airborne particulates. Purifier Logic+ Class II, Type A2 Biosafety Cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-connected, the biosafety cabinets may be used for applications involving volatile toxic chemicals and radionuclides as an adjunct to microbiological research. These benchtop cabinets are available in 3', 4', 5' and 6' nominal widths. See pages 10-11 for ordering information. Purifier Logic+ Class II, Type B2 Biosafety Cabinets are designed to be hard ducted to the outside. Since none of the air is recirculated, these cabinets may be used for work with agents treated with volatile toxic chemicals and radionuclides. These benchtop cabinets are available in 4' and 6' nominal widths. See pages 12-13 for ordering information. ~30% Exhausted 100% Exhausted ~70% Recirculated 0% Recirculated Class II, Type B2 Airflow Class II, Type A2 Airflow During operation, room air is drawn into the inlet grille. The air in the plenum beneath the work surface is a mixture of unfiltered room air, and air that has just passed through the work area. This contaminated air is drawn by the blower through the back plenum of the cabinet, where approximately 70% of the air is recirculated through the supply HEPA filter and back over the work area. The balance of the contaminated air is discharged to the environment after passing through the exhaust HEPA filter. Room Air HEPA-Filtered Air During operation, room air is drawn through the top of the cabinet. This air is HEPA filtered, and then flows downward through the work area. Room air is also drawn into the inlet grille. All of the contaminated air is drawn under the work surface or through the rear grille, then up the rear plenum, and through the exhaust HEPA filter. A dedicated exhaust system and remote blower draw 100% of the filtered exhaust air out of the laboratory. The ductwork and remote blower are required for operation and sold separately. Unfiltered Air under Negative Pressure Unfiltered Air under Positive Pressure 7 Purifier Logic + Class II Biosafety Cabinets ® ® Optional Features & Benefits Specialized work requires special features Cell research often involves using a microscope, keeping the cells at the proper temperature for viability, or both. At the same time, the work must be conducted in a biological safety cabinet to protect the cells, researcher and environment. The Purifier Cell Logic+ Biosafety Cabinet has special features that address the unique needs of cell research. Cell Logic+ Features & Benefits: • Scope-Ready™ package option. Models are available that allow a customer-supplied microscope to be integrated into the cabinet. The sash has a 7.0" wide x 10.5" high (18 x27cm) cutout that accommodates most microscopes’ eyepieces. • The Pure-Vu™ Seal, made of flexible and clear material, surrounds the cutout preventing contaminants from escaping while providing ergonomic visibility into the cabinet. Modified ASHRAE 110 and NSF 49 testing confirms that this unique teardrop collar design keeps contaminants contained. An accessory Pure-Vu™ XL Seal is available to accommodate forward-mounted microscopes. • The Stand-Still™ Isolation Platform completes the Scope-Ready™ package and is sold separately. The platform supports the microscope on the cabinet’s work surface and reduces vibration threefold. Modified ASHRAE 110 and NSF 49 testing confirms this elevated aerodynamic base maintains safe airflow. Constructed of seamless Type 304 stainless steel, the non-porous platform is easy to clean and autoclavable. The platform is available in two sizes and is sold separately. • Temp-Zone™ package option. Models are available that include a temperature-controlled area on the work surface, 10.5" wide x 12.0" deep (7.0" wide x 12.0" deep on 3' models). Warmed or chilled samples may be transferred to the Temp-Zone and kept at optimum temperature. Quick connection fittings on the left side of the cabinet attach to a user-supplied circulator that continually delivers chilled or heated liquid to the Temp-Zone area. Uniform temperature distribution is maintained on the surface. Easy-Clean™ Prop Rods allow for hands-free elevation of the work surface for ease of cleaning and access to the channels and drain. * American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA The accessory Pure-Vu Seal and Stand-Still XL Isolation Platform accommodate forward-mounted microscopes such as stereo scopes. 8 The Temp-Zone package option includes the temperature-controlled area of the work surface (shown above left) and the Easy-Clean Prop Rods (shown above right). Purifier Logic + Class II Biosafety Cabinets ® ® Optional Features, Benefits & Accessories Accessory Package adds functionality to your biosafety cabinet The optional Accessory Package caters to your unique biosafety cabinet wants and needs. Three features are factory-installed so that you can put them to immediate use: UV lamp, service fixture and Vacu-Pass Cord & Cable Portal. The 254 nm UV lamp provides secondary decontamination while the cabinet is not in use. An interlocked switch permits the UV light to operate only when the sash is completely closed. The service fixture supplies water, vacuum, air or noble gases to the cabinet interior. It has a ball-type valve that provides smooth operation at pressures up to 40 psi. The serrated hose tip valve with quarter turn control handle is mounted 8.5" (20 cm) above the work surface to maximize usable surface area. One service fixture is mounted on the right-hand side on 3', 4' and 5' models with Accessory Package. Two service fixtures, one on each side, come with 6' models with Accessory Package. The Vacu-Pass™ Cord & Cable Portal combines safety and convenience. The portal allows passage of cords through the side wall of the cabinet so that cords are kept out of the way of the user’s work area. The NSF-approved port does not disrupt the cabinet’s airflow or allow leakage to occur. One portal comes mounted on the righthand side interior on models with Accessory Package. A plug seals the opening when not in use. Telescoping Base Stand (non-welded) For ease of ordering, some models of the Purifier Logic+ and Cell Logic+ Biosafety Cabinets include the Telescoping Base Stand. The stand is shipped unassembled allowing it to be sent in the same package with the biosafety cabinet. The base stand includes a free shelf and has telescoping legs so that the appropriate height for your application and user can be selected during installation. Ventus™ Canopy Connection provides ducting for your Class II, Type A2 cabinet Certain applications, such as working with malodorous samples, small amounts of volatile toxic chemicals and tracer quantities of radionuclides, require the connection of your Class II, Type A2 cabinet to an exhaust system. The NSF-approved Ventus Canopy Connection mounts above the biosafety cabinet to allow thimble ducting to the outside. Unlike canopies that rely on imprecise pressure or airflow sensors, the Ventus has an uncomplicated mechanical design that ensures safe and reliable operation. In less than one second after a low flow event is detected, the alarm on the LCD alerts the user while the blower speeds to full capacity to maximize personal safety. The low profile Ventus adds only 1.25" to the overall height of the cabinet. These accessories and more are also available for on-site installation. See Accessories and Base Cabinets Ordering Information starting on page 15. 9 Purifier Logic + Class II, Type A2 Biosafety Cabinets ® ® Catalog Number Configurator Use this key to configure the nine digit catalog number to order your Purifier Logic+ or Cell Logic+ Class II, Type A2 Biosafety Cabinet. For example, a 302311100 is a 3' Purifier Logic+ Class II, Type A2 Biosafety Cabinet with 10" sash opening, service fixture, UV lamp, Vacu-Pass Portal, non-welded base stand and North America, 115 volt electrical receptacle and plug. STEP 1: Select the Cell Logic+ package(s) option. This number is the second digit of your catalog number. STEP 2: Select the width of your cabinet. This number is the fourth digit of your catalog number. 0 = None. Logic+ only. 2 = Temp-Zone Package. Fifth digit is 9 3 = 3' (Actual width = 42.3"/107.4 cm) 4 = 4' (Actual width = 54.3"/137.9 cm) 5 = 5' (Actual width = 66.3"/168.4 cm) 6 = 6' (Actual width = 78.3"/198.9 cm) and sixth digit is 1. 3 = Scope-Ready Package. Fifth digit is 9 and sixth digit is 1. STEP 3: Select the sash opening height. This number is the fifth digit of your catalog number. 1 = 10" (25.4 cm). Logic+ only. 8 = 8" (20.3 cm). Logic+ only. 9 = 9" (22.9 cm). Cell Logic+ only. 4 = Temp-Zone & Scope-Ready Packages. Fifth digit is 9 and sixth digit is 1. 3 _ 2 _ _ _ North America, 115 volts, 20 amps Japan, 100 volts, 20 amps* 115 volt, 15 amp 115 volt, 15 amp India For Catalog For Catalog Numbers ending Numbers ending British (UK) in 00 & 20 British (UK) in 00 & 20 India For Catalog Numbers India ending in 10 115 volt, 20 amp British (UK) 115 volt, 15 amp Schuko 115 volt, 20 amp 115 volt, 20 amp 115 volt, 20 amp 115 volt, 15 amp British (UK) North America, 230 volts _ 115 volt, 20 amp 115 volt, 15 amp Electrical Receptacle & Plug Configurations North America, 115 volts, 15 amps Japan, 100 volts, 15 amps _ STEP 6: Select the electrical receptacle and plug type. This number is the eighth and ninth digits of your catalog number. 00 = North America, 115 volts (15 amps for 3' and 4' models. 20 amps for 5' and 6' models) 10 = North America, 230 volts 20 = Japan, 100 volts (15 amps for 3' and 4' models. 20 amps for 5' and 6' models) 30 = Schuko, 230 volts 40 = China/Australia, 230 volts 50 = British (UK), 230 volts 70 = India, 230 volts STEP 5: Select nonwelded telescoping base stand option. This number is the seventh digit of your catalog number. 0 = None 1 = Includes an non-welded tele- scoping base stand shipped with the cabinet. STEP 4: Select the Accessory Package option: service fixture(s), UV lamp and Vacu-Pass™ Cord & Cable Portal. This number is the sixth digit of your catalog number. 0 = None. Logic+ only. 1 = Includes a right-side mounted factory-installed service fixture (two on 6' models, one on each side), UV lamp with timer (UV lamp not included with Scope-Ready), and right-side wall Vacu-Pass Portal. Comes standard on all Cell Logic+ models. _ Schuko, China/Australia 230 volts North America 230 volt British (UK) China/Australia, 230 volts For Catalog Numbers China/Australia ending in 40 115 volt, 15115 amp volt, 15 amp British (UK), 230 volts India China/Australia Schuko For Catalog Numbers ending in 30 Schuko India British (UK)British (UK) For Catalog Numbers Schuko ending in 50 North America 230 volt Schuko For Catalog Numbers ending in 70 Technical Specifications Nominal Width Actual Width Schuko Schuko Shipping Weight Shipping Weight including stand Exhaust Volume, 10" Sash Opening Exhaust Volume, China/Australia 8" Sash Opening China/Australia Exhaust Volume, 9" Sash Opening 3' 4' 42.3" (107.4 cm) 510 lbs. (231 kg) 585 lbs. (265 kg) 253-279 CFM 203-223 CFM 228-251 CFM 54.3" (137.9 cm) 585 lbs. (265 kg) 670 lbs. (304 kg) 339-370 CFM 269-296 CFM 304-333 CFM 12 12 6 12 12 6 Electrical Configuration 115 volts, 60 Hz North America 230 volt America 230 volt 100 volts, 50/60NorthHz 230 volts, 50/60 Hz 10 5' North America 230 volt 66.3" (168.4 cm) 715 lbs. (324 kg) 810 lbs. (367 kg) 420-462 CFM 336-370 CFM 378-416 CFM 6' China/Australia China/Australia 78.3" (198.9 cm) 805 lbs. (365 kg) 905 lbs. (411 kg) 503-554 CFM North America 230 volt 230 volt North America 403-443 CFM 453-498 CFM Amperage Contact Labconco for ordering information on models that are EN 12469 compliant. * Plug is 20 amps. Receptacle is 15 amps. 16 16 8 115 volt, 20115 amp volt, 20 amp India, 230 volts 16 16 8 India India Purifier Logic + Class II, Type A2 Biosafety Cabinets ® ® Specifications Comfort Features Purifier Logic+ Class II, Type A2 Biosafety Cabinet 302411100 • Interior-mounted, line-of-sight, full color LCD information center with easy-to-understand MyLogic™ OS • 21.7" (54 cm) maximum sash opening height and 27.0" (69 cm) viewing height • Curved inlet grille for forearm support • Flush-mounted stainless steel electrical receptacle covers with dampened hinges • Removable, seamless type 304 stainless steel, dished work surface with lift out knobs • 10° Angled sash with counterbalanced, anti-racking mechanism for ease of lifting • ADA-compliant touchpad control on right-hand side post for manual activation of blower, light(s), timer, electrical receptacles, audible alarm mute and menu selection • Noise level < 63 dBA • Heat load 990 BTU/hour (4' models) Specifications Performance Features • Electronically Commutated Motor (ECM) • Constant Airflow Profile™ (CAP) Technology airflow monitoring system that communicates with the ECM to deliver the precise volume of air as required and automatically adjust as filters load without relying on airflow sensors • Air-Wave™ Entry System* • Contain-Air™ Negative Pressure Channel* • Smart-Start™ System that allows the user to program start up and shut down operations • Night-Smart™ System that idles the blower when the sash is fully closed • Built-in interval or elapsed timer for experiment monitoring, fluorescent light or UV light control (on models with UV light) • Digital clock • Removable towel catch located under work surface • Bright, 90-100 footcandle, glare-free fluorescent lighting located outside the contaminated work area • Five year warranty Safety Features • LCD information center with “Filter Life Remaining” bar graph, status line for alarm conditions and alerts to warn when filter life diminishes to 20% and 0% • Electronic security lock (optional activation) that requires code to operate the cabinet • Two electrical duplex receptacles, (single outlets on 230 volt models), located one on each side, with ground fault interruption (115 volt models) • Intrinsically safe negative pressure design • Fully-closing, clear 1/4" tempered safety glass sash • Stainless steel inlet grille with Reserve-Air™ Secondary Airflow Slots* • Supply and exhaust 99.99% efficient HEPA filters. Contact Labconco for optional 99.999% efficient ULPA filters. • Leak-tight stainless steel interior • Nominal inflow velocity of 105 feet per minute (fpm) (0.5 m/sec) • Nominal downflow velocity of 55 fpm (0.3 m/sec) • Approximately 70% air recirculation • Powder-coated steel exterior • NSF International listed (Logic+ models). NSF International and modified ASHRAE 110 compliant (Cell Logic+ models). • ETL listed • CE conformity marking (230 volt models) • Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100) • Overall depth x height: 31.2" x 61.7" (79.2 x 156.7 cm) • 10' (3 m) power cord with plug Options • Non-welded, NSF-Approved, powder-coated steel telescoping base stand with fixed feet • Accessory Package: 254 nm UV lamp, ADA-compliant service fixture(s) with ball-type valve(s), and NSF-Approved Vacu-Pass™ Cord & Cable Portal • Cell Logic+ Packages: Scope-Ready™ Package consisting of 7.0" wide x 10.5" high (18 x 27 cm) sash cutout and Pure-Vu™ Seal with powder-coated steel collar. Stand-Still™ Isolation Platform is required and sold separately. See page 16. Temp-Zone™ Package consisting of temperature-controlled work area, 10.5" (27 cm) wide x 12.0" (30 cm) deep (7.0" x 12.0" on 3' models) located on the left side of the work surface. Circulator is required (not included). Circulator requirements: minimum flow rate of 0.4-0.5 GPM (1.5-1.9 LPM), typical volume of 6 liters, and temperature of 0-50° C (chiller/heater). • Ventus™ Canopy Connection, NSF-Approved, with low flow design and audio/visual alarms (adds 1.25" to overall cabinet height) Required Accessory • Supporting base if non-welded stand option is not selected Exclusive Labconco feature *U.S. Patent No. 6,368,206 Complies with Americans with Disabilities Act Standard for height of controls and receptacles See Dimensional Data on page 14, Accessories on pages 15-17, and Base Stands on pages 18-20. 11 Purifier Logic + Class II, Type B2 Biosafety Cabinets ® ® Catalog Number Configurator Use this key to configure the nine digit catalog number to order your Purifier Logic+ or Cell Logic+ Class II, Type B2 Biosafety Cabinet. For example, a 303481100 is a 4' Purifier Logic+ Class II, Type B2 Biosafety Cabinet with service fixture, UV lamp, Vacu-Pass Portal, non-welded base stand and North America, 115 volt electrical receptacle and plug. STEP 1: Select the Cell Logic+ package(s) option. This number is the second digit of your catalog number. STEP 2: Select the width of your cabinet. This number is the fourth digit of your catalog number. 0 = None. Logic+ only. 2 = Temp-Zone Package. Sixth digit is 1. 3 = Scope-Ready Package. Sixth digit is 1. 4 = Temp-Zone & Scope-Ready Packages. 4 = 4' (Actual width = 54.3"/137.9 cm) 6 = 6' (Actual width = 78.3"/198.9 cm) Sixth digit is 1. 3 _ 3 _ 8 STEP 4: Select nonwelded telescoping base stand option. This number is the seventh digit of your catalog number. 0 = None 1 = Includes an non-welded tele- scoping base stand shipped with the cabinet. STEP 3: Select the Accessory Package option: service fixture(s), UV lamp and Vacu-Pass™ Cord & Cable Portal. This number is the sixth digit of your catalog number. 0 = None. Logic+ only. 1 = Includes a right-side mounted factory-installed service fixture (two on 6' models, one on each side), UV lamp with timer (UV lamp not included with Scope-Ready), and right-side wall Vacu-Pass Portal. Comes standard on all Cell Logic+ models. 115 volt, 15 amp British (UK) Schuko _ _ _ _ STEP 5: Select the electrical receptacle and plug type. This number is the eighth and ninth digits of your catalog number. 00 = North America, 115 volts (15 amps for 4' models. 20 amps for 6' models) 10 = North America, 230 volts 20 = Japan, 100 volts (15 amps for 3' and 4' models. 20 amps for 5' and 6' models) 30 = Schuko, 230 volts 40 = China/Australia, 230 volts 50 = British (UK), 230 volts 70 = India, 230 volts 115 volt, 20 amp 115 volt, 20 amp 115 volt, 15 amp India 115 volt, 20 amp British (UK) 115 volt, 15 amp India Electrical Receptacle & Plug Configurations North America, 115 volts, 15 amps Japan, 100 volts, 15 amps North America, 115 volts, 20 amps Japan, 100 volts, 20 amps* 115 volt, 15 amp 115 volt, 15 amp For Catalog For Catalog Numbers ending Numbers ending British (UK) in 00 & 20 British (UK) in 00 & 20 North America, 230 volts 115 volt, 20 amp 115 volt, 20 amp India For Catalog Numbers India ending in 10 Schuko, China/Australia 230 volts North America 230 volt For Catalog Numbers ending in 30 British (UK) China/Australia, 230 volts Schuko China/Australia Schuko For Catalog Numbers China/Australia ending in 40 115 volt, 15115 amp volt, 15 amp British (UK), 230 volts India British (UK)British (UK) For Catalog Numbers Schuko ending in 50 North America 230 volt Schuko For Catalog Numbers ending in 70 Technical Specifications Nominal Width Schuko Schuko Exhaust Volume** CBV † Shipping Weight Shipping Weight including stand 4' 665 CFM 810 CFM @ 1.9" 650 lbs. (295 kg) 730 lbs. (331 kg) China/Australia China/Australia Electrical Configuration 115 volts, 60 Hz 100 volts, 50/60 Hz North America 230 volt 230 volts, 50/60NorthHz America 230 volt 12 North America 230 volt 6' 998 CFM 1218 CFM @ 2.2" 840 lbs. (381 kg) 940 lbs. (426 kg) Amperage 12 12 6 12 12 8 * Plug is 20 amps. Receptacle is 15 amps. ** Exhaust Volume values are obtained using a Direct Inflow Measurement (DIM) meter sealed to the front of the cabinet. † Concurrent Balance Values (CBV) are obtained using a Pitot or thermal anemometer traverse of the exhaust duct. Static pressure is the amount of vacuum required at the cabinet connection when the HEPA filters are new. 115 volt, 20115 amp volt, 20 amp India, 230 volts China/Australia China/Australia North America 230 volt 230 volt North America India India Purifier Logic + Class II, Type B2 Biosafety Cabinets ® ® Specifications Comfort Features Purifier Logic+ Class II, Type B2 Biosafety Cabinet 303481100 • Interior-mounted, line-of-sight, full color LCD information center with easy-to-understand MyLogic™ OS • 21.7" (54 cm) maximum sash opening height and 27.0" (69 cm) viewing height • Curved inlet grille for forearm support • Flush-mounted stainless steel electrical receptacle covers with dampened hinges • Removable, seamless type 304 stainless steel, dished work surface with lift out knobs • 10° Angled sash with counterbalanced, anti-racking mechanism for ease of lifting • ADA-compliant touchpad control on right-hand side post for manual activation of blower, light(s), timer, electrical receptacles, audible alarm mute and menu selection • Noise level < 63 dBA • Heat load 990 BTU/hour (4' models) Specifications Performance Features • Electronically Commutated Motor (ECM) • Constant Airflow Profile™ (CAP) Technology airflow monitoring system that communicates with the ECM to deliver the precise volume of air as required and automatically adjust as filters load without relying on airflow sensors • Air-Wave™ Entry System* • Contain-Air™ Negative Pressure Channel* • Smart-Start™ System that allows the user to program start up and shut down operations • Built-in interval or elapsed timer for experiment monitoring, fluorescent light or UV light control (on models with UV light) • Digital clock • Removable towel catch located under work surface • Bright, 90-100 footcandle, glare-free fluorescent lighting located outside the contaminated work area • Five year warranty Safety Features • LCD information center with “Filter Life Remaining” bar graph, status line for alarm conditions and alerts to warn when filter life diminishes to 20% and 0% • Electronic security lock (optional activation) that requires code to operate the cabinet • Two electrical duplex receptacles, (single outlets on 230 volt models), located one on each side, with ground fault interruption (115 volt models) • Intrinsically safe negative pressure design • Fully-closing, clear 1/4" tempered safety glass sash with 8" (20 cm) working height opening • Stainless steel inlet grille with Reserve-Air™ Secondary Airflow Slots* • Supply and exhaust 99.99% efficient HEPA filters. Contact Labconco for optional 99.999% efficient ULPA filters. • Leak-tight stainless steel interior • Nominal inflow velocity of 105 feet per minute (fpm) (0.5 m/sec) • Nominal downflow velocity of 55 fpm (0.3 m/sec) • 0% air recirculation • Powder-coated steel exterior • NSF International listed (Logic+ models). NSF International and modified ASHRAE 110 compliant (Cell Logic+ models). • ETL listed • CE conformity marking (230 volt models) • Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100) • Overall depth x height: 31.2" x 61.7" (79.2 x 156.7 cm) • 10" diameter exhaust outlet with air-tight damper • 10' (3 m) power cord with plug Options • Non-welded, NSF-Approved, powder-coated steel telescoping base stand with fixed feet • Accessory Package: 254 nm UV lamp, ADA-compliant service fixture(s) with ball-type valve(s), and NSF-Approved Vacu-Pass™ Cord & Cable Portal • Cell Logic+ Packages: Scope-Ready™ Package consisting of 7.0" wide x 10.5" high (18 x 27 cm) sash cutout and Pure-Vu™ Seal with powder-coated steel collar. Stand-Still™ Isolation Platform is required and sold separately. See page 16. Temp-Zone™ Package consisting of temperature-controlled work area, 10.5" wide x 12.0" deep (27 x 30 cm) located on the left side of the work surface. Circulator is required (not included). Circulator requirements: minimum flow rate of 0.4-0.5 GPM (1.5-1.9 LPM), typical volume of 6 liters, and temperature of 0-50° C (chiller/heater). Required Accessory • Supporting base if non-welded stand option is not selected Exclusive Labconco feature *U.S. Patent No. 6,368,206 Complies with Americans with Disabilities Act Standard for height of controls and receptacles See Dimensional Data on page 14, Accessories on pages 15-17, and Base Stands on pages 18-20. 13 C C Exhaust Outlet 10.0"Outlet (25.410.0" cm) ID Exhaust (25.4 cm) OD 9.1" 9.1" (23.1 ®cm) (23.1 cm) Purifier Logic + Class II, Biosafety Cabinets ® Dimensional Data Class II, Type A2 2.0" (5.1 cm) Exhaust Outlet 10.0" (25.4 cm) ID C Optional Ventus ™ Ventus ™ Optional Canopy Connection Canopy Connection 9.1" (23.1 cm) 63.3" (160.8 cm)(166.1 cm) 65.4" with Optional with Optional Ventus ™ Canopy Ventus ™ Canopy ConnectionConnection 61.7"* 61.7"* (156.7 cm) (156.7 cm) Overall Overall TOP 2.0" (5.1 cm) Nominal A B C Width Inches/cm Inches/cm Inches/cm 3' 42.3/107.4 36.5/92.7 13.6/34.5 4' 54.3/137.9 48.5/123.2 19.9/50.5 5' 66.3/168.4 60.5/153.7 26.9/68.3 6' 78.3/198.9 72.5/184.2 32.9/83.6 Optional Optional 8.0", 9.0" or 10.0" 8.0", 10.0" or 9.0" Scope-Ready ™ (20.3, 22.9(20.3, or 25.4 cm)or 22.9 ™ 25.4 cm) Scope-Ready Working Height Working HeightPackage Package ™ Optional Ventus21.7" (55.121.7" cm) (55.1 cm) Canopy Connection MAX MAX C 8.8" (22.4 cm) 8.8" (22.4 cm) C Exhaust Outlet 10.0"Outlet (25.4 10.0" cm) OD Exhaust (25.4 cm) OD B B 63.3" (160.8 cm) A with Optional A Ventus ™ Canopy FRONT Connection 61.7"* (156.7 cm) Overall 25.7" 25.7" (65.3 cm) (65.3 cm) 29.2" 29.2" (74.2 cm) (74.2 cm) 17.6" 17.6" (44.7 cm) (44.7 cm) 31.2" 31.2" (79.2 cm) (79.2 cm) SIDE Optionalvaries. All Purifier Cell Logic+ Class II, Type A2 Biosafety Cabinets have a 9.0" working height. 8.0", 9.0" orworking 10.0" Sash opening height (20.3, 22.9 or 25.4 cm) Scope-Ready ™ Remaining cabinets have either an 8.0" or 10.0" working height depending on the model. Working Height Package 25.7" 29.2" (74.2 cm) cm) *Exhaust21.7" collar(55.1 is 2.0" high (5.0 cm). MAX (65.3 cm) Class II, Type B2 C 8.8" (22.4 cm) 17.6" (44.7 cm) 31.2" (79.2 cm) Exhaust Outlet 10.0" (25.4 cm) OD B A 72.6" 72.6" (184.4 cm) (184.4 cm) 61.6" 61.6" (156.0 cm) (156.0 cm) Optional Optional 8" (20 cm) 8" (20 cm) ™ Scope-Ready ™ Working Height Working Height Scope-Ready 29.2" 21.7" (55.1 21.7" cm) (55.1 cm) Package Package 29.2" (74.2 cm) (74.2 cm) MAX MAX TOP Nominal A Width B C 25.7" 25.7" (65.3 cm) (65.3 cm) 4' 54.3" 48.5" 17.2" (137.9 cm) (123.2 cm) (43.7 cm) 6' 78.3" 72.5" 28.9" (198.9 cm) (184.2 cm) (73.4 cm) B A 72.6" (184.4 cm) B A FRONT 17.6" 17.6" (44.7 cm) (44.7 cm) 31.2" 31.2" (79.2 cm) (79.2 cm) SIDE 61.6" (156.0 cm) 8" (20 cm) Select the Pure-Vu™ Optional Seal that’s right for you. Scope-Ready Working Height ™ Package 21.7" (55.1 cm) 1. To determine placement of the cutouts, MAX measure from the centerline of the eyepieces to the base of your microscope. Center line of eyepiece Nominal eyepiece height 14 B A 29.2" 2. (74.2 For inverted scopes with relatively 25.7" cm) cm) stationary eyepiece height, select(65.3 a PureVu Seal corresponding with the nominal eyepiece height in the drawing below. All 17.6" 0.5" Dia. (44.7 cm) 17.00" (E) 31.2" (D) 16.00"(79.2 cm) 15.00" (C) (B) 14.00" (A) 13.00" Dimensions shown indicate distance from base of microscope to centerline of eyepiece. Blank Pure-Vu Seal Catalog #4027800 is not shown. Pure-Vu™ Seal Catalog #4027817 Catalog #4027816 Catalog #4027815 Catalog #4027814 Catalog #4027813 3. For stereo scopes or inverted scopes requiring frequent eyepiece height adjustment, select a Pure-Vu XL Seal (shown at right). Pure-Vu XL Seals are designed to be pleated when installed to allow for eyepiece height flexibility of +/-2.0" (5 cm). The Pure-Vu XL Seals extend 5.5" (14 cm) below the collar. 0.5" Dia. (F) 16.00" (+/-2.00" ) Catalog #4027811 includes hole cutouts. Blank Pure-Vu XL Seal Catalog #4027810 is not shown. 4. Refer to the ordering information on page 16 for Pure-Vu and Pure-Vu XL Seals recommended for specific microscope models. Pure-Vu™ XL Seal Purifier Logic + Class II, Biosafety Cabinets ® ® Accessories for All Models IV Bar Kits 3402800 Vacu-Pass™ Cord & Cable Port Kit Include IV bar, mounting hardware and four hangers. Installation is required. Catalog # 3858600 3858601 3858602 3858603 For use with 3-Ft Class II, Type A2 & B2 4-Ft Class II, Type A2 & B2 5-Ft Class II, Type A2 & B2 6-Ft Class II, Type A2 & B2 Allows passage of a cord or cable through the right-side interior wall to the exterior. Cabinets are factory-prepared for easy on-site installation. Includes a set of 4 closed-cell neoprene plugs with holes for cords/cables with diameters of 1/8", 1/4", 3/8" and 1/2". Also includes a blank plug for sealing the port during nonuse. NSF-approved port does not disrupt airflow or cause leakage. Shipping weight 2 lbs. (1 kg) Shipping Wt. 3 lbs. (1 kg) 4 lbs. (2 kg) 5 lbs. (2 kg) 6 lbs. (3 kg) VACUUBRAND* BVC Basic Fluid Aspiration Systems 3744000 Ergonomic Chair with Armrests 6-way articulating seat and back control for personalized adjustment. Pneumatic mechanism adjusts seat height from 18.25" to 25.75" (46 x 64 cm). Five-leg reinforced composite base with 2" (5 cm) diameter ball-bearing casters. Aluminum support ring. Removable armrests. Black vinyl upholstery. Shipping weight 35 lbs. (16 kg) Designed for connection to an external vacuum source such as a diaphragm pump. Mechanical vacuum controller opens when needed to limit gas consumption from the vacuum source. Each system includes a coated steel base, an autoclavable collection bottle, aspiration hand set with flow-through suction tube and PTFE 0.2 micron filter to help prevent contaminants from entering the vacuum source. Shipping weight 6.2 lbs. (3 kg) 3746000 Adjustable Footrest Elevates feet and permits angle repositioning while in use. 18.5" w x 11.5" d x 8.0" (47 x 29 x 20 cm). Shipping weight 6 lbs. (3 kg) 8022000 Logic Cart Drawer and compartments provide convenient storage. Top left side compartment with cutouts and hinged panel that pivots down for loading. High density polyethylene and ABS construction. Overall dimensions: 25.0" w x 19.0" d x 27.0" h (64 x 48 x 69 cm). Shipping weight 50 lbs. (23 kg) 3852000 Turntable “Lazy Susan” rotates 360° to bring items within easy reach. Stainless steel surface and ball bearings. 12" (30 cm) diameter. Autoclavable. Shipping weight 5 lbs. (2 kg) 3859100 Cord Management System Includes three stainless steel mounting hooks and three carabiners. The hooks mount to the rear grille and the carabiners secure power cords and tubing along the rear wall to keep them contained and away from the work area. Shipping weight 3 lbs. (1 kg) 3859000 Interior Shelf Stainless steel shelf, 8.0" x 5.0" (20 x 13 cm), mounts to rear grille. Weight capacity: 2.2 lbs. (1 kg). Shipping weight 3 lbs. (1 kg) 3405500 Inflow and Downflow Sensor Kit Allows display of inflow and downflow velocities on the LCD information center. Includes sensor, wiring harness and hardware. Not for use on Class II, Type B2 cabinets. Installation and certifier calibration are required. Contact Labconco about factory-installed sensors. Shipping weight 3 lbs. (1 kg) RS 232 Connection Kits For connecting the biosafety cabinet to a data recorder or building monitoring system. Include the PC board, cable and hardware. Catalog # 3858310 3858311 For use with Shipping Wt. Kit contains cable with 9-pin connection 1 lb. (0.5 kg) Kit contains cable with 25-pin connection 1 lb. (0.5 kg) Catalog # Aspiration System includes: Dimensions (L x W X H) 3850310 4 Liter Polypropylene Collection Bottle 9.9 x 7.9 x 19.3" 3850320 2 Liter Borosilicate Glass Collection Bottle 9.1 x 7.1 x 17.0" VACUUBRAND* BVC Control Fluid Aspiration Systems Chemical-resistant PTFE diaphragm pump, capable of drawing 12 L/minute and achieving ultimate vacuum of 150 mBar/112 Torr, is included. Mechanical vacuum controller opens when needed to limit gas consumption from the vacuum source. Each system includes a coated steel base, adjustable suction power control via touch panel from 150 to 850 mBar, an autoclavable collection bottle, aspiration hand set with flow-through suction tube and PTFE 0.2 micron filter to help prevent contaminants from entering the vacuum source. Shipping weight 17 lbs. (8 kg) Systems with 4 Liter Polypropylene Collection Bottle Dimensions (L x W x H): 16.1" x 7.6" x 19.7" (41 x 19 x 50 cm) Catalog # 3850330 3850331 3850332 3850333 3850334 3850335 Electrical Requirements 115 volts, 50/60 Hz 230 volts, 50/60 Hz 230 volts, 50/60 Hz 230 volts, 50/60 Hz 230 volts, 50/60 Hz 230 volts, 50/60 Hz Plug Type 115 volts, 15 amps North America, 230 volts Schuko China/Australia British (UK) India Systems with 2 Liter Borosilicate Glass Collection Bottle Dimensions (L x W x H): 16.1" x 7.6" x 16.9" (41 x 19 x 43 cm) Catalog # 3850340 3850341 3850342 3850343 3850344 3850345 * Electrical Requirements 115 volts, 50/60 Hz 230 volts, 50/60 Hz 230 volts, 50/60 Hz 230 volts, 50/60 Hz 230 volts, 50/60 Hz 230 volts, 50/60 Hz Plug Type 115 volts, 15 amps North America, 230 volts Schuko China/Australia British (UK) India VACUUBRAND® is a registered trademark of VACUUBRAND GMBH + CO KG 15 Purifier Logic + Class II Biosafety Cabinets ® ® Accessories for All Models 3747500 Service Fixture Kit Includes serrated hose tip valve with ball valve, quarter turn control handle and hardware. Mounts on left or right side interior. Cabinets are factoryprepared for up to four fixtures: two forward mounted 8.5" above surface and two back mounted 10" above surface. Installation is required. Shipping weight 4 lbs. (2 kg) Ultraviolet Lamp Kits Include 254 nm UV lamp and ballast. Not recommended for Cell Logic+ Biosafety Cabinets with Scope-Ready package. Installation is required. Catalog # 3858500 3858501 3858502 For use with Shipping Wt. 115 Volt Class II, Type A2 & B2 100 Volt Class II, Type A2 & B2 230 Volt Class II, Type A2 & B2 5 lbs. (2 kg) 5 lbs. (2 kg) 5 lbs. (2 kg) Purifier Logic + Class II Biosafety Cabinets ® ® A c c e s s o r i e s f o r C e l l L o g i c+ M o d e l s Pure-Vu™ Seals Each Cell Logic+ Biosafety Cabinet with Scope-Ready Package comes with two clear blank membranes (one each 4027800 and one each 4027810), which may be cut with 0.5" diameter holes or punched with Pure-Vu Punch Kit 4027801 to fit your microscope’s eyepieces. Convenient, pre-punched seals may be ordered separately. See instructions and drawings on page 14 for reference. Microscope examples are provided below. Please contact Labconco for ordering assistance for seals to fit microscopes not listed. Shipping weight 0.5 lb. (0.2 kg) Reference Catalog # Nominal Eye Piece Height* Fits Microscope: not shown 4027800 Universal Pure-Vu. Blank. (A) 4027813 13.0" (33.0 cm) (B) 4027814 14.0" (35.6 cm) Zeiss† Axiovert† 40 (C) 4027815 15.0" (38.1 cm) Nikon† Eclipse† TS 100, Olympus† CKX31 (D) 4027816 16.0" (40.6 cm) Leica† DM IL LED (E) 4027817 17.0" (43.2 cm) Leica† DM 6000 B not shown 4027810 Universal Pure-Vu XL. Blank. (F) 4027811 16.0" (+/-2.0") Leica† MZ95 (40.6 cm, +/- 5.1 cm) Nikon† SMZ 1500 Olympus† SZX 16 Stand-Still™ Isolation Platforms Required for supporting microscopes on Cell Logic Biosafety Cabinets with Scope-Ready™ package. Designed to promote proper airflow through the cabinet. Reduces vertical and horizontal vibrations threefold. Constructed of seamless, non-porous, autoclavable Type 304 stainless steel base with isolation pads. 1.5" high (0.4 cm). Select the platform that best fits your microscope’s dimensions. Catalog # Description Shipping Wt. 4028200 Stand-Still Platform, 12.0 x 18.75" (30.5 x 47.6 cm) 8 lbs. (4 kg) 4028100** Stand-Still XL Platform, 14.0 x 22.75" (35.6 x 57.8 cm) 10 lbs. (5 kg) **Requires use of Pure-Vu XL Seal 4027810 or 4027811. Universal Tube Baths Blue anodized aluminum blocks hold tubes of various sizes in an aluminum bead bath. Aluminum promotes the conduction of heat or cold from the Temp-Zone™ area to help maintain sample temperature. Thermally-conductive beads are sold separately. * When selecting a seal for a Cell Logic+ Class II, Type B2 Biosafety Cabinet, add one inch to your eyepiece height and use the chart above. † Zeiss® and Axiovert® are registered trademarks Carl-Zeiss-Stiftung DBA Carl Zeiss Corporation. Nikon® and Eclipse® are registered trademarks of Nikon, Inc. Olympus® is a registered trademark ® of O lympus Corporation. Leica is a registered trademark of Leica Technology. 4027801 Pure-Vu™ Punch Kit For punching accurate eyepiece holes in blank Pure-Vu seals. Includes 1/2" (12.7 mm) diameter hole punch, cutting pad and instructions. Shipping weight 1 lb. (0.5 kg) Catalog # Aluminum Tube Racks Blue anodized aluminum blocks hold tubes upright and promote conduction of heat or cold from the Temp-Zone™ area to help maintain sample temperature. 16 Tube Size/Description Catalog # 4026600 Description Shipping Wt. Small Bath, 0.25 L capacity 2.0" w x 4.0" d x 3.0" h (50.8 x 101.6 x 76.2 mm) 4026601 Large Bath, 0.5 L capacity 4.0" w x 4.0" d x 3.0" h (101.6 x 101.6 x 76.2 mm) 4026602 Lab Armor†† Beads, 0.75 liter Tube Capacity 4026400 0.5 ml microcentrifuge, 7.5 mm 4026401 0.5 ml microcentrifuge, 7.5 mm 4026402 1.5 ml microcentrifuge, 10.5 mm 4026403 1.5 ml microcentrifuge, 10.5 mm 4026404 1.5 ml flat bottom, 10 mm 4026405 5 ml flat bottom, 12 mm 4026406 6 ml flat bottom, 13 mm 4026407 15 ml round, 16-17 mm 4026408 15 ml conical, 16-17 mm 4026409 50 ml round, 28 mm 4026410 50 ml conical, 28 mm 4026411 microtiter well plate, 3.4" x 5.0" (86 x 127 mm) 1.5 ml microcentrifuge 0.5 ml microcentrifuge Dimensions (w x d x h) 2 lbs. (1 kg) 2 lbs. (1 kg) 5 lbs. (2 kg) Shipping Weight 18 1.5 x 6.0 x 1.3" (38 x 152 x 32 mm) 2 lbs. (1 kg) 96 6.0 x 8.0 x 1.5" (152 x 203 x 38 mm) 8 lbs. (3 kg) 18 2.0 x 6.0 x 1.5" (51 x 152 x 38 mm) 2 lbs. (1 kg) 96 8.0 x 8.0 x 1.5" (203 x 203 x 38 mm) 9 lbs. (4 kg) 12 1.5 x 4.0 x 1.3" (38 x 102 x 32 mm) 1 lb. (0.5 kg) 12 2.0 x 5.0 x 2.5" (51 x 127 x 64 mm) 3 lbs. (1 kg) 12 2.0 x 5.0 x 2.5" (51 x 127 x 64 mm) 3 lbs. (1 kg) 12 2.0 x 6.0 x 3.0" (51 x 152 x 76 mm) 4 lbs. (2 kg) 12 2.0 x 6.0 x 4.0" (51 x 152 x 102 mm) 5 lbs. (2 kg) 4 1.5 x 6.0 x 4.0" (38 x 152 x 102 mm) 3 lbs. (1 kg) 4 1.5 x 6.0 x 4.0" (38 x 152 x 102 mm) 3 lbs. (1 kg) 1 6.0 x 8.0 x 1.5" (152 x 203 x 38 mm) 5 lbs. (2 kg) 12 12 Purifier Logic + Class II Biosafety Cabinets ® ® Filters, Ductwork & Blowers Screen Prefilter Starter Kits 3858800 Backdraft Damper Mounts in vertical duct run to prevent reverse pressurization of the exhaust system. 3.0" (8 cm) high with 10" (25.4 cm) diameter OD inlet and outlet. Shipping weight 5 lbs. (2 kg) Each kit consists of a washable/reusable, metal screen-type prefilter and hardware including bracket for installing on the towel catch. Installation is required. Catalog # 3406100 3406101 3406102 3406103 For use with Shipping Wt. 3-Ft Biosafety Cabinet 4-Ft Biosafety Cabinet 5-Ft Biosafety Cabinet 6-Ft Biosafety Cabinet 4 lbs. (2 kg) 5 lbs. (2 kg) 6 lbs. (3 kg) 7 lbs. (3 kg) G4 Prefilter Starter Kits & Replacement Prefilters Pleated disposable filter with Merv 8 rating. Kits include prefilter, hardware and bracket for installing on the towel catch. Installation is required. Kit Catalog # Repl. Prefilter Catalog # For use with 3406200 3406201 3406202 3406203 3-Ft Biosafety Cabinet 4-Ft Biosafety Cabinet 5-Ft Biosafety Cabinet 6-Ft Biosafety Cabinet 3406000 3406001 3406002 3406003 Flexible Hose Kits For connection between the Ventus™ and exhaust ductwork. 10" nominal diameter. Include spiral flexible tubing and clamps. Catalog # Hose Length Shipping Wt. 7034200 1' (30.5 cm) 3' (91.4 cm) 6' (182.9 cm) 10' (304.8 cm) 2 lbs. (1 kg) 5 lbs. (2 kg) 10 lbs. (5 kg) 20 lbs. (9 kg) 7034201 7034202 7034203 Typical Class II Cabinet Exhaust System Zero Pressure Weathercap 7095100, 10" dia. 5622100, 12" dia. Ventus™ Canopy Connection For thimble ducting Class II, Type A2 Biosafety Cabinets. Canopy provides an air gap to allow room air to enter the ductwork and mix with the filtered air being exhausted to the outside. Inadequate exhaust activates the switch in less than one second and signals the LCD to display an alarm and the motor to increase to maximum speed for personal safety. Adds only 1.25" to the overall height of the cabinet. Powder-coated steel. Outlet is 10" (25.4 cm) ID. Exhaust connection is required. Damper 3776800 and Remote Blower 7068000 or 7068200 are recommended (not included). Contact Labconco for information on factory installation. Shipping weight 15 lbs. (7 kg) Catalog # For use with Total Exhaust Volume (Safety Cabinet and Room Air) 8" Sash Opening 9" Sash Opening 10" Sash Opening 3889200 3889201 3889202 3889203 3-Ft Class II, Type A2 4-Ft Class II, Type A2 5-Ft Class II, Type A2 6-Ft Class II, Type A2 223-353 289-369 356-470 423-543 248-351 324-433 398-516 473-598 Duct Reducer 5606100, 10" x 12" dia. Flexible Duct Connection 7034200, 11" dia. 90° Elbow 7027300, 10" dia. Male Duct Coupling 12" dia. 7067300 Air-Tight Damper (included with Type B2 and accessory for Canopy-ducted Type A2) 273-379 359-470 440-562 523-654 Remote Blowers Required for Type B2 cabinets and recommended for canopy-ducted Type A2 cabinets. Phenolic-coated impeller and housing, powder-coated steel base and weather cover, belt-drive motor with adjustable sheave and self-adjusting gravity belt tightener. Contact Labconco for dimensions and blowers of other sizes and electrical configurations. Blower Transition Adapter, 4722401, 10" dia. 7003400, 12" dia. Remote Blower Thermoplastic Duct 7027200, 10" dia. Canopy Connection (Type A2 only) or Sealed Connection (Type B2 only) 3776800 Air-Tight Damper Mounts atop the Canopy Connection to adjust exhaust airflow and closes for decontamination procedures. Manually adjustable. Type 304 stainless steel. 10" (25.4 cm) high with 10" (25.4 cm) diameter OD inlet and outlet. Shipping weight 13 lbs. (6 kg) Backdraft Damper 3858800, 10" dia. Thermoplastic Duct 7027200, 10" dia. 5602000, 12" dia. Contact Labconco at 800-821-5525 or 816-333-8811 for ordering information and technical assistance in selecting the right ductwork for your installation. Inlet Outlet Blower Transition Adapter Required 7068000 & 7068200 7071900 10.87" (27.6 cm) ID 5.5" d x 10.0" w (14 x 25 cm) 12.25" (31.1 cm) OD 7.0" x 13.5" (18 x 34 cm) 4722401 7003400 Catalog # For use with Electrical Requirements HP CFM Range† Shipping Weight 7068000 3-Ft & 4-Ft Type A2 Cabinets 5-Ft & 6-Ft Type A2 Cabinets 4-Ft & 6-Ft Type B2 Cabinets 115 volts, 60 Hz, 1 phase, 4.0 amps 115 volts, 60 Hz, 1 phase, 4.4 amps 230/460 volts, 60 Hz, 3 phase, 5.8/2.9 amps 1/6 1/4 2 370 @ .12" to 410 @ .38" 540 @ .25" to 430 @ .75" 977 @ 3.4" to 1161 @ 4.7" 92 lbs. (42 kg) 92 lbs. (42 kg) 100 lbs. (45 kg) 7068200 7071900 † Air volume at static pressure in inches H2O 17 Purifier Logic + Class II Biosafety Cabinets ® ® Telescoping Base Stands (Non-Welded) These stands have telescoping legs so that they may be adjusted to eight height positions.* Standard Features • NSF-approved. Meet NSF Standard for stability and construction. • Support Purifier Logic Biosafety Cabinets. • Support loads up to 1000 pounds. • ADA-compliant. • Durable 1.75" tubular, powder-coated steel frame with back panel support. • Telescoping legs are adjustable to eight height positions at installation in 1" (2.5 cm) increments to provide a working height from 30" (76 cm) to 37" (94 cm).* Telescoping Base Stand (non-welded) 3401004 • 9" (23 cm) shelf is included. Telescoping Base Stands (non-welded) • Four fixed leveling feet are provided. Nominal Width Catalog # Shipping Weight • Unassembled. May be easily assembled with simple hand tools. 3-Ft 3401003 117 lbs. (53 kg) * Height selection and adjustment are required before the enclosure is installed on the stand. 4-Ft 3401004 125 lbs. (57 kg) 5-Ft 3401005 133 lbs. (60 kg) Catalog # Nominal Width A 6-Ft 3401006 149 lbs. (68 kg) 3401003 3-Ft 38.5" (97.8 cm) 3401004 4-Ft 50.5" (128.3 cm) 3401005 5-Ft 62.5" (158.8 cm) 3401006 6-Ft 74.5" (189.2 cm) A 27.5" (69.9 cm) min. 34.5" (87.6 cm) max. ** Enclosures supported by mobile Base Stands will require special modifications to incorporate flexible ducting, wiring and plumbing when applied. Comply with height and knee clearance guidelines outlined in ADA Standards for Accessible Design. 3730500 Caster Kit For converting Telescoping Base Stands with Fixed Feet to mobile stands. Kit includes four 5" diam29.0" (73.7 cm) eter, non-marking polyurethane 1.8" (4.6 cm) 11.8" (30.1 cm) casters with toe locks. Load rating for each caster is 250 pounds. Casters have bearings for quiet operation. Casters replace the fixed feet included with Telescoping Base Stands. Casters add 11" (28 cm) to the overall depth of the Crossbar base stand. Installation is required. Not for use with stands that support Purifier Logic Class II, Type B2 Safety Cabinets. Shipping weight 10 lbs. (5 kg) 9.1" (22.9 cm) 3857000 Seismic Bracket Kit For securing the Telescoping Base Stand to the floor in earthquake-prone regions. Includes four stainless steel seismic brackets and hardware for attachment to the stand. Hardware to attach to the floor and installation are required. Shipping weight 10 lbs. (5 kg) Shelf FRONT 29.0" (73.7 cm) 1.8" (4.6 cm) 27.5" (69.9 cm) min. 34.5" (87.6 cm) max. Crossbar 9.1" (22.9 cm) Shelf SIDE 18 Laptop Computer Arms 11.8" (30.1 cm) Contact Labconco for ordering information on welded telescoping base stands. Securely support a laptop computer within easy view of an operator at the Cell Logic+. Mount to front leg of front leg of Telescoping Base Stands or front of SoLo Base Stands (see back cover). Articulating arm raises, lowers and pivots to a steady position. Include powder-coated steel arm and support surface with cloth loop fasteners and mounting hardware. Not for use with other Hydraulic Lift Base Stands. Installation is required. Catalog # For use with Shipping 3869300 Telescoping Base Stand 12 lbs. (5 kg) 3869200 Solo Hydraulic Lift Base Stand 12 lbs. (5 kg) Purifier Logic + Class II Biosafety Cabinets ® ® Hydraulic Lift Base Stands These stands have a built-in hydraulic lift so that height may be adjusted at any time. They allow the user to position the stand and the safety cabinet it supports to accommodate persons of different heights and wheelchair-bound users, to transport equipment through doorways, and for easier access to services. Standard Features • Meet NSF Standard for stability and construction. • Support Purifier Logic Biosafety Cabinets. • Support loads up to 1000 pounds. • ADA-compliant. • Durable 1.75" (4.4 cm) tubular, epoxy-coated steel frame with rear crossbar supports. Sub-frame has 2.0" (5.1 cm) x 3.0" (7.6 cm) rectangular tubing. • Height is infinitely adjustable from 25.5" (64.8 cm) to Hydraulic Lift Base Stand 3780201. 33.5" (85.1 cm) high. • Include four powder-coated, die-cast feet with levelers. • Include front-accessible up/down switch (Electric Lift models) • Include front-accessible hand crank. Turning the crank clockwise raises the stand; counterclockwise lowers it. The handle may be disengaged and folded under, out of the way, when not in use. (Manual Lift models) • Shipped fully assembled. Catalog Numbers Nominal Width 3780100, 3780103, 3780200 3780101, 3780104, 3780201 3780106, 3780107, 3780203 3780102, 3780105, 3780202 3-Ft 4-Ft 5-Ft 6-Ft A B 38.5" 39.7" 50.5" 51.7" 62.5" 63.9" 74.5" 75.7" Nominal Width Catalog # Description 3-Ft 3780100 3-Ft 3780103† Electric. 115 volts, 60 Hz, 2.4 amps Electric. 230 volts, 50/60 Hz, 0.8 amp 3-Ft 3780200 Manual 4-Ft 3780101 Electric. 115 volts, 60 Hz, 2.4 amps 4-Ft 3780104† Electric. 230 volts, 50/60 Hz, 0.8 amp 4-Ft 3780201 Manual 5-Ft 3780106 Electric. 115 volts, 60 Hz, 2.4 amps 5-Ft 3780107† Electric. 230 volts, 50/60 Hz, 0.8 amp 5-Ft 3780203 Manual 6-Ft 3780102 Electric. 115 volts, 60 Hz, 2.4 amps 6-Ft 3780105† Electric. 230 volts, 50/60 Hz, 0.8 amp 6-Ft 3780202 Manual Up/Down Switch A 29.0" 9.5" 16.0" B 34.3" FRONT FRONT SIDE SIDE MANUAL LIFT Manual Lift Includes four 5" (13 cm) diameter, non-marking polyurethane casters with toe locks and bearings. Load rating for each caster is 250 pounds. Casters replace the fixed feet and add 11" (28 cm) to the overall depth of the base stand. Installation is required.** Not for use with stands that support Type B2 Safety Cabinets. Shipping weight 10 lbs. (5 kg) 4028600 Support Shelf Provide a work surface to support remote equipment. Powder-coated steel shelf mounts to left-side tubular frame of base stand. 12.0" w x 22.0" deep (26 x 30 cm). Installation is required. Shipping weight 23 lbs. (10 kg) Hand Crank A 7.4" 170 lbs. (77 kg) 170 lbs. (77 kg) 170 lbs. (77 kg) 185 lbs. (84 kg) 185 lbs. (84 kg) 185 lbs. (84 kg) 215 lbs. (98 kg) 215 lbs. (98 kg) 215 lbs. (98 kg) 225 lbs. (102 kg) 225 lbs. (102 kg) 225 lbs. (102 kg) Caster Kit 3784000 ELECTRIC Electric LiftLIFT 25.5" min. 33.5" max. Shipping Weight 29.0" 4.4" 25.5" min. 33.5" max. ** Enclosures supported by mobile Base Stands will require special modifications to incorporate flexible ducting, wiring and plumbing when applied. B 34.3" FRONT FRONT SIDE SIDE † International electrical configuration Complies with Americans with Disabilities Act Standard for height of controls and receptacles 19 Purifier Logic + Class II Biosafety Cabinets ® ® S o l o™ B a s e S t a n d s SoLo™ Hydraulic Lift Base Stands are specifically designed to support Purifier Logic+ and Cell Logic+ Class II, Type A2 Biosafety Cabinets. The hydraulic lift system permits the stand to be lowered allowing the safety cabinet to be rolled through standard doorways as low as 78" (198 cm) high. Casters provide mobility and lock in place for stability. Standard Features • Meet NSF Standard for stability and construction. • Support any Purifier Logic+ or Cell Logic+ Class II, Type A2 Safety Cabinet. • ADA-compliant. • Durable powder-coated steel construction. • Support loads up to 1300 pounds (590 kg). • Built-in hydraulic lift is operated by a remote control with SoLo Hydraulic Lift Base Stand 3780311. buttons for upward and downward movement. Height adjustment positions the enclosure for persons of different statures, wheel-chair bound users, transport through doorways, and easier service access to upper components. A • Infinitely adjustable height provides work surface heights from 17.2" (43.7 cm) to 36.8" (93.5 cm) and overall enclosure height as low as 76.2" (193.5 cm). 39.9" MIN 59.5" MAX • 5" (13 cm) diameter, toe-locking, non-marking polyurethane casters with bearings for quiet operation. • Two handle bars on each side facilitate transport. Bars are durable PVC-coated steel tubes with polyamide brackets. • Accommodate Laptop Computer Arm 3869200, sold separately. 14.0" MIN 33.6" MAX See page 18. • Shipped fully assembled. Nominal Width Actual Width (A) Catalog # 3-Ft. 53.5" 3780310 3-Ft. 53.5" 3780314 3-Ft. 53.5" 3780330 3-Ft. 53.5" 3780334 3-Ft. 53.5" 3780338 4-Ft. 65.5" 3780311 4-Ft. 65.5" 3780315 4-Ft. 65.5" 3780331 4-Ft. 65.5" 3780335 4-Ft. 65.5" 3780339 5-Ft. 77.5" 3780312 5-Ft. 77.5" 3780316 5-Ft. 77.5" 3780332 5-Ft. 77.5" 3780336† 5-Ft. 77.5" 3780340 6-Ft. 89.5" 3780313 6-Ft. 89.5" 3780317 6-Ft. 89.5" 3780333 6-Ft. 89.5" 3780337 6-Ft. 89.5" 3780341 34.3" Electrical Requirements Plug Type Additional Load Capacity* Shipping Weight 115 volts, 60 Hz, 2 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 115 volts, 60 Hz, 2 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 115 volts, 60 Hz, 2 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 115 volts, 60 Hz, 2 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 230 volts, 50/60 Hz, 3 amps 115 volts, 15 amps North America, 230 volts British (UK), 230 volts Schuko, 230 volts China/Australia, 230 volts 115 volts, 15 amps North America, 230 volts British (UK), 230 volts Schuko, 230 volts China/Australia, 230 volts 115 volts, 15 amps North America, 230 volts British (UK), 230 volts Schuko, 230 volts China/Australia, 230 volts 115 volts, 15 amps North America, 230 volts British (UK), 230 volts Schuko, 230 volts China/Australia, 230 volts 700 lbs. (318 kg) 700 lbs. (318 kg) 700 lbs. (318 kg) 700 lbs. (318 kg) 700 lbs. (318 kg) 600 lbs. (272 kg) 600 lbs. (272 kg) 600 lbs. (272 kg) 600 lbs. (272 kg) 600 lbs. (272 kg) 500 lbs. (227 kg) 500 lbs. (227 kg) 500 lbs. (227 kg) 500 lbs. (227 kg) 500 lbs. (227 kg) 350 lbs. (159 kg) 350 lbs. (159 kg) 350 lbs. (159 kg) 350 lbs. (159 kg) 350 lbs. (159 kg) 395 lbs. (179 kg) 395 lbs. (179 kg) 395 lbs. (179 kg) 395 lbs. (179 kg) 395 lbs. (179 kg) 435 lbs. (197 kg) 435 lbs. (197 kg) 435 lbs. (197 kg) 435 lbs. (197 kg) 435 lbs. (197 kg) 460 lbs. (209 kg) 460 lbs. (209 kg) 460 lbs. (209 kg) 460 lbs. (209 kg) 460 lbs. (209 kg) 600 lbs. (272 kg) 600 lbs. (272 kg) 600 lbs. (272 kg) 600 lbs. (272 kg) 600 lbs. (272 kg) Labconco Corporation 8811 Prospect Avenue • Kansas City, MO 64132-2696 816-333-8811 or 800-821-5525 • FAX: 816-363-0130 E-MAIL: labconco@labconco.com • HOME PAGE: www.labconco.com © 2013 by Labconco Corporation • Printed in the U.S.A. Product design subject to change without notice • 2-04-GC-3/13-4M-R1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2013:03:14 15:17:52-05:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2014:06:25 15:28:09-07:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:06:25 15:28:09-07:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:c8fa5357-5299-40e5-9723-bab87404042a Original Document ID : xmp.did:F77F1174072068118C14A5B63BB16E0C Document ID : xmp.id:9FDDEE7D2A2068118083E16EA7BAB9BB Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:9EDDEE7D2A2068118083E16EA7BAB9BB Derived From Document ID : xmp.did:9EDDEE7D2A2068118083E16EA7BAB9BB Derived From Original Document ID: xmp.did:F77F1174072068118C14A5B63BB16E0C Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2013:03:14 15:17:52-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 20EXIF Metadata provided by EXIF.tools