3B TECH COOL-P800 Mini-split air conditioner User Manual Rollibot MiniSplitAC UM 0403 indd
3B TECH Inc Mini-split air conditioner Rollibot MiniSplitAC UM 0403 indd
3B TECH >
User Manual
Copyright © 2017. Rollibot, LLC. All Rights Reserved USER MANUAL
SAVE THIS MANUAL FOR FUTURE REFERENCE
Rollibot-MiniSplitAC-UM-0403.indd Spread 1 of 12 - Pages(24, 1)Rollibot-MiniSplitAC-UM-0403.indd Spread 1 of 12 - Pages(24, 1) 4/10/2017 7:41:18 PM4/10/2017 7:41:18 PM
www.rollibot.com
Customer Service: 1-844-585-6295
23
RolliBot RolliCool Mini-Split AC User Manual
Important: Do not disassemble the Product. Disassembling the Product will void this Warranty.
Only WP or a party expressly authorized by WP should perform service on this Product.
DISCLAIMER OF WARRANTY: THE REMEDIES DESCRIBED ABOVE ARE YOUR SOLE AND EXCLUSIVE REMEDIES
AND OUR ENTIRE LIABILITY FOR ANY BREACH OF THIS LIMITED WARRANTY. OUR LIABILITY SHALL UNDER NO
CIRCUMSTANCES EXCEED THE ACTUAL AMOUNT PAID BY YOU FOR THE DEFECTIVE PRODUCT, NOR SHALL
WE UNDER ANY CIRCUMSTANCES BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, SPECIAL OR PUNITIVE
DAMAGES OR LOSSES, WHETHER DIRECT OR INDIRECT.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
THE DURATION AND REMEDIES OF ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE
DURATION OF THIS EXPRESS LIMITED WARRANT
Rollibot-MiniSplitAC-UM-0403.indd Spread 2 of 12 - Pages(2, 23) 4/10/2017 7:41:19 PM
FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Warning: Changes or modications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment o and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body
22 RolliBot RolliCool Mini-Split AC User Manual
Section 8. Warranty
8.1 – Violation
The RolliCool Mini-Split Air Conditioner cannot be repaired or serviced within its warranty
period if any of the following has occurred:
• The warranty has expired
• Damage occurred during or in relation to non-routine and/or unauthorized disassembly
• Failure to provide a valid proof of purchase when requesting service or repair
• Damage occurred as a result of natural disaster etc.
• Damage occurred due to unexpected factors or man-made reasons (including mis-
operation, uid found in any openings, improper insertion or pulling, hauling, bumping,
improper voltage input and others)
8.2 – Information
ONE YEAR LIMITED HARDWARE WARRANTY
Your RolliCool Mini-Split Air Conditioner (“Product”) includes a One Year Limited Hardware
Warranty (“Warranty”). The Warranty covers product defects in materials and workmanship
under normal use. This Warranty is limited to residents of the United States and Canada only and
is available only to original purchasers. This Warranty gives you speci c legal rights, and you
may also have other rights which vary from state to state.
This Warranty starts on the date of your purchase and lasts for one year (the “Warranty Period”).
The Warranty Period is not extended if the Product is repaired or replaced. We may change the
availability of this limited warranty at our discretion, but any changes will not be retroactive.
Warranty services are provided by Warranty Pro (“WP”). If a hardware defect arises and a valid
claim is received within the Warranty Period, at its option and to the extent permitted by law,
WP will: (1) repair the hardware defect by using new or refurbished parts that are equivalent to
new in performance and reliability; or (2) exchange the Product with a product that is new or
refurbished which is substantially equivalent to the original product. This Warranty is for one
replacement only of like-items and does not cover items out of production if the product is no
longer made or stocked. This Warranty is not assignable or transferable. The original purchaser
may call WP’s toll-free number at 1-844-585-6295 for a service request.
When a product or part is exchanged, any replacement item becomes your property, and
the replaced item becomes WP’s property. This warranty only covers technical hardware
defectiveness during the warranty period and under normal use conditions. WP does not
warrant uninterrupted or error-free operation of this Product.
This Warranty does not cover any damage due to: (a) transportation; (b) storage; (c) improper
use; (d) failure to follow the product instructions or to perform any preventive maintenance; (e)
modi cations; (f) unauthorized repair; (g) normal wear and tear; or (h) external causes such as
accidents, abuse, or other actions or events beyond our reasonable control.
Dear Rollibot RolliCool Owner,
Welcome to the new age of cool!
The RolliCool COOL-P800 is an AC unit that uses the latest technology to improve your
quality of life. We’ve designed this unit to be easy to install and use in your home. It
features multiple modes to help keep you cool no matter what the weather’s like!
The COOL-P800 is designed for indoor use (with exhaust outside) and can be used in
di erent sized spaces. Included accessories make it easy to install the unit just about
anywhere. There’s even a remote control for a little more convenience!
All of the unit’s features are available through the RolliCool app. After pairing your AC
unit and your smartphone, stay cool however you like!
Thank you for being a part of the Rollibot family!
— The RolliBot Team
Rollibot-MiniSplitAC-UM-0403.indd Spread 3 of 12 - Pages(22, 3)Rollibot-MiniSplitAC-UM-0403.indd Spread 3 of 12 - Pages(22, 3) 4/10/2017 7:41:19 PM4/10/2017 7:41:19 PM
4RolliBot RolliCool Mini-Split AC User Manual
Table of Contents
Section 1. Information & Safety Warnings ........................................................... 5
1.1 – Introduction ................................................................................................... 5
1.2 – Safety Warnings .............................................................................................. 5
1.3 – Installation Warnings ..................................................................................... 5
1.4 – FCC Information .............................................................................................. 6
1.5 – Disposal at End-of-Life ................................................................................... 6
Section 2. RolliCool Parts ........................................................................................ 7
2.1 – Box Contents ................................................................................................... 7
2.2 – Components Overview ................................................................................... 7
2.3 – Control Panel ................................................................................................... 8
2.4 – Remote Overview .......................................................................................... 10
Section 3. Setting Up the AC .................................................................................. 11
3.1 – Installing the Indoor Unit .............................................................................. 11
3.3 – Connecting the Coupler ................................................................................ 14
Section 4. App Setup .............................................................................................. 16
Section 5. How to Use the RolliCool ..................................................................... 16
5.1 – Auto Mode ...................................................................................................... 16
5.2 – Cooling Mode ................................................................................................. 17
5.3 – Dehumidify Mode .......................................................................................... 17
5.4 – Fan Only Mode ............................................................................................... 18
5.5 – Timer ............................................................................................................... 18
Section 6. Maintenance .......................................................................................... 19
6.1 – How to Clean the Filters ................................................................................ 19
6.2 – How to Clean the Indoor Unit ....................................................................... 20
6.3 – How to Drain the Unit .................................................................................... 20
6.4 – How to Clear Water from Drainage Pipe ...................................................... 20
Section 7. Troubleshooting .................................................................................... 21
Section 8. Warranty ............................................................................................... 22
8.1 – Violation ......................................................................................................... 22
8.2 – Information .................................................................................................... 22
21
RolliBot RolliCool Mini-Split AC User Manual
Section 7. Troubleshooting
Problems Possible Causes Solution(s)
The unit does
not work.
There is no electricity. Turn it on after connecting it to a socket
with electricity.
The over ow indicator displays. Drain the water inside.
The indoor temperature is too
low or too high.
Use the unit when the indoor temperature
is between 44-95 F (7-35 C ).
Change the set temperature.
The cooling
e ect is weak.
There is direct sunlight. Cover any direct sunlight coming through
the windows.
Doors or windows are open;
there are a lot of people; or
there are other sources of heat.
Close doors and windows.
The lter is dirty. Clean or replace the lter.
The air inlet or outlet is blocked. Clear obstructions.
Excessive
Noise
The unit is not placed on a at
surface.
Put the unit on a at and stable surface.
Compressor
Issues
Overheating protection started. Wait 3 minutes until the temperature is
lowered then restart the unit.
The remote
control does
not work.
The remote and unit are too far
apart.
Get closer to the RolliCool and make sure
that the remote control directly faces the
unit.
The remote isn’t pointed in the
right direction.
Batteries are dead. Replace batteries.
When the RolliCool encounters errors, the display may show certain error codes. Refer to the
table below.
Code Possible Cause Solution(s)
E0 Water has collected in the unit. Unplug the unit. Use the Drainage Pipe and drain
out any water. Restart the unit.
E1 Indoor temp. sensor failure Contact customer service for troubleshooting.
E2 EVA sensor failure Contact customer service for troubleshooting.
E6 Overcooling The unit was turned on when the indoor
temperature was too low. Adjust the temperature
as needed.
E7 Overheating If the cooling e ect is weak, remove and clean
the lters. Restart the unit.
If none of the above information resolves your issue, please visit our website at www.rollibot.
com or contact customer service at 1-844-585-6295.
Rollibot-MiniSplitAC-UM-0403.indd Spread 4 of 12 - Pages(4, 21)Rollibot-MiniSplitAC-UM-0403.indd Spread 4 of 12 - Pages(4, 21) 4/10/2017 7:41:19 PM4/10/2017 7:41:19 PM
20 RolliBot RolliCool Mini-Split AC User Manual
3. Remove the lter and empty the debris into a waste receptacle.
4. Rinse the lter in lukewarm water if desired and allow time for it to
dry before replacing it.
5. Mild detergents may also be used.
6.2 – How to Clean the Indoor Unit
• Wipe the exterior clean with a non-abrasive cloth. If needed, the cloth can be damp-
ened with water.
• Do not use harsh chemicals to clean as these may damage the unit.
• Be careful to keep water out of the interior.
6.3 – How to Drain the Unit
In most cases, the Indoor Unit will not require draining. If this is necessary in some special case,
follow the instructions below.
Please make sure your AC unit is completely powered o before performing any
type of maintenance.
1. After turning o the RolliCool, unplug it.
2. If needed, remove the Drainage Pipe’s stopper and
drain the water down away from the unit. Using a bucket is
recommended.
3. To completely dry the inside, use Fan Only Mode for at
least two hours.
4. If the Drainage Pipe needs an extension, materials to do
so can be purchased at most hardware stores.
6.4 – How to Clear Water from Drainage Pipe
If the Drainage Pipe has excessive water that needs to be cleared, follow the instructions below.
Please make sure your AC unit is completely powered o before performing any type of maintenance.
Step 1. Unplug the unit and remove the Indoor Unit from the wall.
Step 2. Place the unit on a sturdy surface and remove the Coupler Cover.
Step 3. Use needle nose pliers to pinch the Drainage Pipe’s metal clasp to release the pipe from
the unit.
Step 4. Clear the water from the Drainage Pipe.
Step 5. Connect the Drainage Pipe back to the unit and push the clasp around the pipe where it
is connected to the unit.
Step 6. Use needle nose pliers to x the metal clasp back in place.
Step 7. Replace the cover, add and tighten the screw, and place the unit back on the wall.
Drainage
5
RolliBot RolliCool Mini-Split AC User Manual
Section 1. Information & Safety Warnings
1.1 – Introduction
This user manual will guide you through the functions and usage of your RolliCool Mini-Split Air
Conditioner. It is important that you follow all instructions and pay attention to all notes that
appear throughout this manual. Consult this manual before you attempt to use your RolliCool
Mini-Split AC. If you have questions not answered by this manual or are in need of repair or
non-routine service, contact customer service at 1-844-585-6295. Before contacting customer
service, please have your purchase information ready as this may be needed during the call. This
information may be recorded below.
Date of Purchase:
Place of Purchase:
1.2 – Safety Warnings
When reading this manual, note these icons:
Notes with this icon MUST be read, understood, and obeyed to prevent injury or damage etc.
Notes with this icon include relevant information.
Overall Usage
• Do not insert objects into the product.
• The product is not a toy. Do not leave children unsupervised around the product.
• The product is designed for indoor use only.
• Keep the product upright at all times.
• Do not use the product near any of the following places:
• Near anything ammable
• Direct sunlight
• Damp areas
• Dusty areas
• Do not use wax, thinner, or solvents when cleaning the air conditioner.
• Clean your lter once or more every couple of weeks.
• Do not place any obstacles in front of the inlet.
• Do not pull the power lines.
• In the event that the product is malfunctioning, shut the power o immediately.
• Switch o the product before cleaning.
• If used in homes near saltwater locations, the unit may be subject to accelerated
corrosion.
• You should only use parts you have received from RolliBot™ or that have been included
in the original packaging.
• Do not use the product for any purpose other than described in this user manual.
1.3 – Installation Warnings
INDOOR UNIT
• Do not install the indoor unit in a sloped setting.
• Do not install the indoor unit in direct sunlight.
Rollibot-MiniSplitAC-UM-0403.indd Spread 5 of 12 - Pages(20, 5)Rollibot-MiniSplitAC-UM-0403.indd Spread 5 of 12 - Pages(20, 5) 4/10/2017 7:41:19 PM4/10/2017 7:41:19 PM
6RolliBot RolliCool Mini-Split AC User Manual
• Do not install in places with open ames or ammable gas.
• Do not use extension cords etc. Only plug the indoor unit into a grounded wall outlet.
• Install in clear area without any obstructions nearby.
• Avoid installing the indoor unit in damp areas.
• Install near the wall with space to link the coolant lines between the indoor and outdoor
unit.
OUTDOOR UNIT
• Never install the outdoor unit in a place where the product is likely to fall.
• Make sure to drain the outdoor unit with the drainage pipe.
• Do not install the outdoor unit in direct sunlight.
• Do not install the outdoor unit near open ames or by ammable gas.
• Do not install the outdoor unit in extremely windy areas.
1.4 – FCC Information
DECLARATION OF CONFORMITY:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
FCC RELATED INFORMATION:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit di erent from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modi cations to this equipment. Such modi cations could void the user’s authority to operate
the equipment.
1.5 – Disposal at End-of-Life
This product must not be disposed of by incineration, land lling, or mixing with household
trash. Improper disposal of the battery contained within this product may result in the battery
heating up, rupturing, or igniting which may cause serious injury. The refrigerants contained
inside the RolliCool present chemical risks to the environment. The recommended disposal
for any RolliCool Portable Air Conditioner at its end-of-life is to dispose of the entire unit by
contacting your local recycling company. Local regulations and laws pertaining to the recycling
19
RolliBot RolliCool Mini-Split AC User Manual
• When a schedule is active, the unit will not turn on if the chosen temperature is higher than the indoor temperature.
TO SET A SHUTOFF TIME
1. When the unit and remote are on, press the Timer Button on the Control Panel or the remote.
2. Use the Up and Down Buttons to select the time the AC unit will turn o i.e. selecting “03” will
prompt the unit to turn o in 3 hours’ time etc.
3. After the selection is complete, the display will show the current indoor temperature and the
Schedule Light.
Section 6. Maintenance
Proper maintenance will help improve your RolliCool’s performance. The RolliCool will
periodically need its lter cleaned. For optimal performance, the lters should be cleaned at
least twice a month. It is also recommended to regularly inspect the Drainage Pipe.
If any type of non-routine maintenance is needed, such as any maintenance not described in Section 6 of this manual,
please contact customer service or a certi ed HVAC professional as the unit contains refrigerant.
6.1 – How to Clean the Filters
• Please make sure your AC unit is completely powered o before performing any type of maintenance.
• Do not scrape the air lters as it may sustain damage.
• A hand vacuum or low-powered vacuum or vacuum modes may be used to clean the lters.
• Replace the lters after cleaning. Do not use the RolliCool without the lters.
1. Pull o the front
panel.
2. Pull out the lter.
1
2
12
Rollibot-MiniSplitAC-UM-0403.indd Spread 6 of 12 - Pages(6, 19)Rollibot-MiniSplitAC-UM-0403.indd Spread 6 of 12 - Pages(6, 19) 4/10/2017 7:41:19 PM4/10/2017 7:41:19 PM
18 RolliBot RolliCool Mini-Split AC User Manual
5.4 – Fan Only Mode
With this mode, the unit will turn on and begin using the fan to promote air circulation.
1. Press the Power Button on the Control Panel or the remote.
2. Press the Mode Button on the Control Panel until the Fan Only Mode icon appears. Or simply
press the Fan Only Button on the remote.
3. Use the Fan Speed Button to change fan speed. Press it multiple times to cycle through 3 fan
speeds.
In Fan Only Mode, the fan speed is automatically set low and cannot be adjusted.
5.5 – Timer
With this mode, the unit will automatically turn on or o and regulate temperature according to
the selected times.
• Setting the schedule when the unit is o means setting the time the unit will turn on.
• Setting the schedule when the unit is on means setting the time the unit will run before it shuts o .
TO SET A TURN ON TIME
1. When the unit and remote are o , press the Timer Button on the Control Panel or the remote.
2. Use the Up and Down Buttons to select the time the AC unit will turn on i.e. selecting “03” will
prompt the unit to turn on in 3 hours’ time etc.
3. After the selection is complete, the display will show the Timer icon.
1
23
2
1
3
1
2
7
RolliBot RolliCool Mini-Split AC User Manual
and disposal of any RolliCool unit and/or products containing them will vary according to your
country, state, and local governments. You must check laws and regulations corresponding to
where you live in order to dispose of your RolliCool unit properly. It is the user’s responsibility to
dispose of their equipment properly in accordance with local regulations and laws.
For additional information about where you should drop o your RolliCool unit, please contact
your local or regional waste management o ce, your household waste disposal service, or your
point-of-sale.
Section 2. RolliCool Parts
2.1 – Box Contents
• 1 x RolliCool Mini-Split AC (Indoor Unit)
• 1 x RolliCool Mini-Split AC (Outdoor Unit)
• 1 x Remote Control
• 2 x Air Filter (pre-installed)
• 4 x Wall Anchors/Screws
• 1 x Window Kit
2.2 – Components Overview
RolliCool Mini-Split AC COOL-P800
(Indoor Unit)
RolliCool Mini-Split AC COOL-P800
(Outdoor Unit)
Remote ControlWall Anchors/Screws
Window Kit
ABC
12
3
4
7
8
11
10
5
6
1Front Panel
2Air Filter
3Handle
4Control Panel
5Remote
6Air Outlet
7Coolant Lines
8Mount Openings
9Coupler Cover
10 Drainage Pipe
11 Power Cord 9
INDOOR UNIT
Rollibot-MiniSplitAC-UM-0403.indd Spread 7 of 12 - Pages(18, 7)Rollibot-MiniSplitAC-UM-0403.indd Spread 7 of 12 - Pages(18, 7) 4/10/2017 7:41:19 PM4/10/2017 7:41:19 PM
8RolliBot RolliCool Mini-Split AC User Manual
2.3 – Control Panel
The RolliCool Mini-Split AC features an LED Control Panel which lights up when the AC unit turns
on and includes buttons.
CONTROL PANEL LIGHTS
Auto. Mode: This icon will light up when the unit is in Auto Mode.
Cool Mode: This icon will light up when the unit is in Cool Mode.
Dehumidify Mode: This icon will light up when the unit is in Dehumidify Mode.
Fan Only Mode: This icon will light up when the unit is in Fan Only Mode.
Celsius: If selected, this icon will light up when the current temperature is being
displayed.
1
2
3
4
5
1Handle
2Air Outlet
3Coolant Lines
4Condensation Outlet
5Coupler
OUTDOOR UNIT
Auto Mode Light
Cool Mode Light
Dehumidify Mode Light
Fan Only Mode Light
Power
Button
Mode
Button
Fan Speed
Button
Down
Button
Up
Button
Celsius Light
Fahrenheit Light
Schedule Light
Fan Speed Light
17
RolliBot RolliCool Mini-Split AC User Manual
5.2 – Cooling Mode
With this mode, the unit will turn on and regulate temperature as selected.
1. Press the Power Button on the Control Panel or the remote.
2. Press the Mode Button on the Control Panel until the Cool Mode light turns on. Press it
multiple times to cycle through di erent modes. Or simply press the Cool Button on the
remote.
3. Use the Up and Down Buttons to set the desired temperature between 61~88°F (16~31C ).
4. Use the Fan Speed Button to change fan speed. Press it multiple times to cycle through 3 fan
speeds.
When Cool Mode is active, the unit will not turn on if the chosen temperature is higher than the indoor temperature.
5.3 – Dehumidify Mode
With this mode, the unit will turn on and begin removing moisture from the air.
1. Press the Power Button on the Control Panel or the remote.
2. Press the Mode Button on the Control Panel until the Dehumidify Mode icon appears. Press it
multiple times to cycle through di erent modes. Or simply press the Dehumidify Button on
the remote.
In Dehumidify Mode, the fan speed is automatically set low and cannot be adjusted.
1
23
2
1
3
1
23
2
1
3
Rollibot-MiniSplitAC-UM-0403.indd Spread 8 of 12 - Pages(8, 17)Rollibot-MiniSplitAC-UM-0403.indd Spread 8 of 12 - Pages(8, 17) 4/10/2017 7:41:35 PM4/10/2017 7:41:35 PM
16 RolliBot RolliCool Mini-Split AC User Manual
Section 4. App Setup
For your convenience, there is an app for the RolliCool. The app is compatible with most Android
and iOS smartphones. The app can be used to set cooling schedules, change modes, and
more. Use your smartphone to search the Play or App Store for the “RolliCool” application then
download and install the app according to your operating system. After downloading the app,
see the steps and images below to use it and connect to your AC unit. For your convenience, the
steps have been divided into parts.
• Either wi- or Bluetooth® may be used for setup. It is not necessary to set up via both methods.
• Powering on the RolliCool will automatically enable Bluetooth® i.e. Bluetooth® will become enabled and stay enabled
as long as the RolliCool is turned on.
• For instructions on how to turn on Bluetooth®, consult materials for your Bluetooth®-enabled smartphone.
• As with most Bluetooth® devices, it is recommended to keep the connected devices at least 32 ft. within each other. The
connection may be terminated or fail to work properly if the connected devices are too far apart.
Section 5. How to Use the RolliCool
The RolliCool Mini-Split AC features a number of ways to keep cool and comfortable. Most
features can be used by pressing the buttons on the unit’s Control Panel, the remote, or via the
app.
In most cases where the remote can be used, the app can also be used as a substitute.
5.1 – Auto Mode
With this mode, the unit will turn on and regulate temperature as selected.
1. Press the Power Button on the Control Panel or the remote.
2. Press the Mode Button on the Control Panel until the Auto Mode light turns on. Press it
multiple times to cycle through di erent modes. Or simply press the Auto Button on the
remote.
3. Use the Up and Down Buttons to set the desired temperature between 61~88°F (16~31C ).
• When Auto Mode is active, the unit will not turn on if the chosen temperature is higher than the indoor temperature.
• In Auto Mode, the fan speed is automatically set and cannot be adjusted.
1
23
2
1
3
9
RolliBot RolliCool Mini-Split AC User Manual
Fahrenheit: If selected, this icon will light up when the current temperature is
being displayed.
Schedule: This icon will light up when a schedule has been programmed.
Fan Speed: This icon will light up and change according to the selected fan speed.
CONTROL PANEL BUTTONS
Power Button: Press to turn the unit on or o .
Mode Button: Press to cycle between Auto, Cool, Dehumidify, and Fan Only
modes.
Fan Speed Button: Press to cycle between 3 fan speeds.
Down Button: Press to lower temperature.
Up Button: Press to raise temperature.
• Scheduling can be done and/or adjusted via the Control Panel, remote, or the app. See the following section for more
information about the remote. See Section 4 for information about the app.
Rollibot-MiniSplitAC-UM-0403.indd Spread 9 of 12 - Pages(16, 9)Rollibot-MiniSplitAC-UM-0403.indd Spread 9 of 12 - Pages(16, 9) 4/10/2017 7:41:36 PM4/10/2017 7:41:36 PM
10 RolliBot RolliCool Mini-Split AC User Manual
Before Using the Remote
Pull the tab to remove the protective lm.
2.4 – Remote Overview
The RolliCool Mini-Split AC features a remote which may be used with the unit.
REMOTE BUTTONS
Power Button: Press to turn the unit on or o .
Auto Button: Press to turn on Auto Mode.
Cool Button: Press to turn on Cool Mode.
Dehumidify Button: Press to turn on Dehumidify Mode.
Fan Only Button: Press to turn on Fan Only Mode.
Schedule Button: Press to turn on Schedule Mode.
Up Button: Press to raise temperature or adjust schedule
duration.
Down Button: Press to lower temperature or adjust schedule
duration.
Fan Speed Button: Press to cycle between 3 fan speeds.
°C/°F Button: Press to switch between Celsius and Fahrenheit.
• Avoid pressing two buttons simultaneously as this may cause malfunctions.
• Avoid using the remote in areas with extreme temperature uctuations.
• If the remote will not be used for extended periods of time, remove the battery.
• The remote control’s range is approximately 23 ft. Use it within this range.
• The remote uses one CR2 (CR2035 3V) battery. This battery is included.
To Change the Battery
Pull part A in towards the remote then pull
part B out to remove the battery tray. Remove
any dead battery and replace with a new
battery, + side up.
15
RolliBot RolliCool Mini-Split AC User Manual
3.4 – Separating the Coupler
If needed, the Indoor and Outdoor Units can be disconnected from one another in case any
adjustments or maintenance is needed. Before separating the coupler from the unit, turn o the
RolliCool, disconnect it from any power supply and wait at least 5 minutes.
Never separate the coupler while the unit is on.
Step 1.
Unscrew the screw at the right side of the
cover. Push the button at the right side of the
cover and pull it away from the unit to remove
it.
Step 2.
Slowly open the latch and hold the Coolant
Lines so that they’re straight. Note, the unit
may emit a chugging sound due to the
refrigerant; this is normal.
Step 3.
Disconnect the power cable from the inside
of the unit. Lift the Coolant Lines up and away
from the unit to remove it.
Step 4.
Insert the rubber stopper into the end of the
Coupler to prevent leakage.
Cover
Keep the Coolant
Lines straight Latch
Power Cable
Rubber Cap
Rollibot-MiniSplitAC-UM-0403.indd Spread 10 of 12 - Pages(10, 15)Rollibot-MiniSplitAC-UM-0403.indd Spread 10 of 12 - Pages(10, 15) 4/10/2017 7:41:36 PM4/10/2017 7:41:36 PM
14 RolliBot RolliCool Mini-Split AC User Manual
Ensure that the rubber stopper is placed in a suitable location. If the Indoor and Outdoor Units are disconnected e.g. when
the unit is being moved, the rubber stopper should be reinstalled into the end of the Coupler. If separating the two, review
the following section.
3.3 – Connecting the Coupler
Step 1.
Unscrew the screw at the right side of the
cover. Push the button at the right side of the
cover and pull it away from the unit to remove
it.
Step 2.
Remove the rubber stopper from the end of
the Coupler if it is installed. Open the latch
and line the Coupler up with its connectors.
Step3.
Make sure the Coupler is properly threaded
into its connectors and push it straight down.
Step 4.
Slowly close the latch, taking care to use even
pressure on the latch.
Step 5.
Connect the power cable to the inside of the
unit.
Step 6.
Replace the Coupler Cover. Make sure to add
the screw.
Cover
Power Cable
Keep the Coolant
Lines straight
11
RolliBot RolliCool Mini-Split AC User Manual
Section 3. Setting Up the AC
3.1 – Installing the Indoor Unit
• Choose a mounting location situated next to a window as the Coolant Lines must be run through a window in order to
keep the Indoor and Outdoor Units connected.
• Using a stud detector for detection and installation into wall studs may be desired for more secure mounting.
Step 1. Choose a suitable
location on the wall for
mounting the unit.
Step 4.
Use a drill to make 4 holes at each of the marks.
Step 5.
Insert the Wall Anchors into the wall.
Step 6.
Add the screws into their anchors making sure a length of
4mm~9mm is left out of the wall.
Step 7.
Install the Indoor Unit onto the wall making sure the
notches in the Mount Openings slide over the screws.
Step 8.
Check to ensure the Indoor Unit is securely installed on the
wall.
Step 9.
Remove the Indoor Unit for now to prepare for connection.
After installing the Outdoor Unit (Section 3.2) and Connecting
the Coupler (Section 3.3), reinstall the Indoor Unit on the wall.
Step 2. Measure between the
Mount Openings on the back
of the unit.
Step 3. Mark locations on
the wall according to the
openings.
H
L
Rollibot-MiniSplitAC-UM-0403.indd Spread 11 of 12 - Pages(14, 11)Rollibot-MiniSplitAC-UM-0403.indd Spread 11 of 12 - Pages(14, 11) 4/10/2017 7:41:36 PM4/10/2017 7:41:36 PM
12 RolliBot RolliCool Mini-Split AC User Manual
WINDOW KIT PARTS
SECTIONS
These sections thread into
one another and should be
placed within a window gap.
A may be ipped so that the
opening is higher or lower.
CONNECTOR
This piece is later inserted into
the opening in Section A and
used to hold the Coolant Lines
in place.
SCREW FASTENER
These parts are used to secure
the sections together and
can be loosened or tightened
when adjusting the sections
according to window height.
ABC Screw Head
Washer
Screw Base
B
A
B
INSTALLATION
Step 1.
Separate one Screw Fastener
and thread the Screw Base
into one end of Section B.
Step 2.
Thread Section A onto the
end of Section B and use the
Screw Head and Washer to
secure the sections together.
Step 3.
Repeat Step 1 one at the other
end of Section B.
B
3.2 – Installing the Outdoor Unit
In order to let o exhaust and hot air, the Outdoor Unit should be placed on level, stable ground
outdoors. The Coolant Lines must be used to connect the two units and may be routed through
a window with the help of the Window Kit.
Please read all installation steps and parts instructions and information before attempting to install.
13
RolliBot RolliCool Mini-Split AC User Manual
Step 9.
Install the assembled kit
into a window gap and push
the window nearly closed
to secure it in place. Use the
fasteners to adjust as needed.
Step 4.
Thread Section C onto the
other end of Section B and
use the Screw Head and
Washer to secure the sections
together.
Step 5.
Separate one Screw Fastener
and thread the Screw Base
into one end of the second
Section B.
Step 6.
Thread the second Section B
into the other end of Section
C and use the Screw Head and
Washer to secure the sections
together.
Step 7.
Thread the Coolant Lines into
the side of the Connector
then t the Connector into
Section A making sure the
notch is in place.
Step 8.
Check that all Sections are
connected like so.
B
A
C
Screw Fasteners
A
B
C
B
B
B
C
Rollibot-MiniSplitAC-UM-0403.indd Spread 12 of 12 - Pages(12, 13)Rollibot-MiniSplitAC-UM-0403.indd Spread 12 of 12 - Pages(12, 13) 4/10/2017 7:41:36 PM4/10/2017 7:41:36 PM