3B TECH COOL-P800 Mini-split air conditioner User Manual Rollibot MiniSplitAC UM 0403 indd
3B TECH Inc Mini-split air conditioner Rollibot MiniSplitAC UM 0403 indd
3B TECH >
User Manual
Copyright © 2017. Rollibot, LLC. All Rights Reserved USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE Rollibot-MiniSplitAC-UM-0403.indd Spread 1 of 12 - Pages(24, 1) 4/10/2017 7:41:18 PM Important: Do not disassemble the Product. Disassembling the Product will void this Warranty. Only WP or a party expressly authorized by WP should perform service on this Product. DISCLAIMER OF WARRANTY: THE REMEDIES DESCRIBED ABOVE ARE YOUR SOLE AND EXCLUSIVE REMEDIES AND OUR ENTIRE LIABILITY FOR ANY BREACH OF THIS LIMITED WARRANTY. OUR LIABILITY SHALL UNDER NO CIRCUMSTANCES EXCEED THE ACTUAL AMOUNT PAID BY YOU FOR THE DEFECTIVE PRODUCT, NOR SHALL WE UNDER ANY CIRCUMSTANCES BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, SPECIAL OR PUNITIVE DAMAGES OR LOSSES, WHETHER DIRECT OR INDIRECT. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THE DURATION AND REMEDIES OF ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS LIMITED WARRANT FCC STATEMENT : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. www.rollibot.com Customer Service: 1-844-585-6295 FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body RolliBot RolliCool Mini-Split AC User Manual Rollibot-MiniSplitAC-UM-0403.indd Spread 2 of 12 - Pages(2, 23) 23 4/10/2017 7:41:19 PM Section 8. Warranty Dear Rollibot RolliCool Owner, 8.1 – Violation The RolliCool Mini-Split Air Conditioner cannot be repaired or serviced within its warranty period if any of the following has occurred: • The warranty has expired • Damage occurred during or in relation to non-routine and/or unauthorized disassembly • Failure to provide a valid proof of purchase when requesting service or repair • Damage occurred as a result of natural disaster etc. • Damage occurred due to unexpected factors or man-made reasons (including misoperation, fluid found in any openings, improper insertion or pulling, hauling, bumping, improper voltage input and others) Welcome to the new age of cool! The RolliCool COOL-P800 is an AC unit that uses the latest technology to improve your quality of life. We’ve designed this unit to be easy to install and use in your home. It features multiple modes to help keep you cool no matter what the weather’s like! The COOL-P800 is designed for indoor use (with exhaust outside) and can be used in different sized spaces. Included accessories make it easy to install the unit just about anywhere. There’s even a remote control for a little more convenience! 8.2 – Information ONE YEAR LIMITED HARDWARE WARRANTY Your RolliCool Mini-Split Air Conditioner (“Product”) includes a One Year Limited Hardware Warranty (“Warranty”). The Warranty covers product defects in materials and workmanship under normal use. This Warranty is limited to residents of the United States and Canada only and is available only to original purchasers. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. All of the unit’s features are available through the RolliCool app. After pairing your AC unit and your smartphone, stay cool however you like! Thank you for being a part of the Rollibot family! — The RolliBot Team This Warranty starts on the date of your purchase and lasts for one year (the “Warranty Period”). The Warranty Period is not extended if the Product is repaired or replaced. We may change the availability of this limited warranty at our discretion, but any changes will not be retroactive. Warranty services are provided by Warranty Pro (“WP”). If a hardware defect arises and a valid claim is received within the Warranty Period, at its option and to the extent permitted by law, WP will: (1) repair the hardware defect by using new or refurbished parts that are equivalent to new in performance and reliability; or (2) exchange the Product with a product that is new or refurbished which is substantially equivalent to the original product. This Warranty is for one replacement only of like-items and does not cover items out of production if the product is no longer made or stocked. This Warranty is not assignable or transferable. The original purchaser may call WP’s toll-free number at 1-844-585-6295 for a service request. When a product or part is exchanged, any replacement item becomes your property, and the replaced item becomes WP’s property. This warranty only covers technical hardware defectiveness during the warranty period and under normal use conditions. WP does not warrant uninterrupted or error-free operation of this Product. This Warranty does not cover any damage due to: (a) transportation; (b) storage; (c) improper use; (d) failure to follow the product instructions or to perform any preventive maintenance; (e) modifications; (f ) unauthorized repair; (g) normal wear and tear; or (h) external causes such as accidents, abuse, or other actions or events beyond our reasonable control. 22 Rollibot-MiniSplitAC-UM-0403.indd Spread 3 of 12 - Pages(22, 3) RolliBot RolliCool Mini-Split AC User Manual 4/10/2017 7:41:19 PM Table of Contents Section 7. Troubleshooting Section 1. Information & Safety Warnings ........................................................... 5 Problems Possible Causes Solution(s) The unit does not work. There is no electricity. Turn it on after connecting it to a socket with electricity. 1.3 – Installation Warnings ..................................................................................... 5 The overflow indicator displays. Drain the water inside. 1.4 – FCC Information .............................................................................................. 6 The indoor temperature is too low or too high. Use the unit when the indoor temperature is between 44-95 0F (7-35 0C ). 1.1 – Introduction ................................................................................................... 5 1.2 – Safety Warnings .............................................................................................. 5 1.5 – Disposal at End-of-Life ................................................................................... 6 Section 2. RolliCool Parts ........................................................................................ 7 Change the set temperature. There is direct sunlight. Cover any direct sunlight coming through the windows. Close doors and windows. 2.3 – Control Panel ................................................................................................... 8 Doors or windows are open; there are a lot of people; or there are other sources of heat. 2.4 – Remote Overview .......................................................................................... 10 The filter is dirty. Clean or replace the filter. Section 3. Setting Up the AC .................................................................................. 11 The air inlet or outlet is blocked. Clear obstructions. Excessive Noise The unit is not placed on a flat surface. Put the unit on a fl at and stable surface. Compressor Issues Overheating protection started. Wait 3 minutes until the temperature is lowered then restart the unit. The remote control does not work. The remote and unit are too far apart. Get closer to the RolliCool and make sure that the remote control directly faces the unit. 2.1 – Box Contents ................................................................................................... 7 The cooling effect is weak. 2.2 – Components Overview ................................................................................... 7 3.1 – Installing the Indoor Unit .............................................................................. 11 3.3 – Connecting the Coupler ................................................................................ 14 Section 4. App Setup .............................................................................................. 16 Section 5. How to Use the RolliCool ..................................................................... 16 5.1 – Auto Mode ...................................................................................................... 16 5.2 – Cooling Mode ................................................................................................. 17 The remote isn’t pointed in the right direction. 5.3 – Dehumidify Mode .......................................................................................... 17 Batteries are dead. 5.4 – Fan Only Mode ............................................................................................... 18 5.5 – Timer ............................................................................................................... 18 Replace batteries. When the RolliCool encounters errors, the display may show certain error codes. Refer to the table below. Code Possible Cause Solution(s) E0 Water has collected in the unit. Unplug the unit. Use the Drainage Pipe and drain out any water. Restart the unit. 6.2 – How to Clean the Indoor Unit ....................................................................... 20 E1 Indoor temp. sensor failure Contact customer service for troubleshooting. 6.3 – How to Drain the Unit .................................................................................... 20 E2 EVA sensor failure Contact customer service for troubleshooting. 6.4 – How to Clear Water from Drainage Pipe ...................................................... 20 E6 Overcooling The unit was turned on when the indoor temperature was too low. Adjust the temperature as needed. E7 Overheating If the cooling effect is weak, remove and clean the filters. Restart the unit. Section 6. Maintenance .......................................................................................... 19 6.1 – How to Clean the Filters ................................................................................ 19 Section 7. Troubleshooting.................................................................................... 21 Section 8. Warranty ............................................................................................... 22 8.1 – Violation ......................................................................................................... 22 8.2 – Information .................................................................................................... 22 Rollibot-MiniSplitAC-UM-0403.indd Spread 4 of 12 - Pages(4, 21) RolliBot RolliCool Mini-Split AC User Manual If none of the above information resolves your issue, please visit our website at www.rollibot. com or contact customer service at 1-844-585-6295. RolliBot RolliCool Mini-Split AC User Manual 21 4/10/2017 7:41:19 PM 3. Remove the filter and empty the debris into a waste receptacle. Section 1. Information & Safety Warnings 4. Rinse the filter in lukewarm water if desired and allow time for it to dry before replacing it. 1.1 – Introduction This user manual will guide you through the functions and usage of your RolliCool Mini-Split Air Conditioner. It is important that you follow all instructions and pay attention to all notes that appear throughout this manual. Consult this manual before you attempt to use your RolliCool Mini-Split AC. If you have questions not answered by this manual or are in need of repair or non-routine service, contact customer service at 1-844-585-6295. Before contacting customer service, please have your purchase information ready as this may be needed during the call. This information may be recorded below. 5. Mild detergents may also be used. 6.2 – How to Clean the Indoor Unit • Wipe the exterior clean with a non-abrasive cloth. If needed, the cloth can be dampened with water. • Do not use harsh chemicals to clean as these may damage the unit. • Be careful to keep water out of the interior. Date of Purchase: Place of Purchase: 6.3 – How to Drain the Unit In most cases, the Indoor Unit will not require draining. If this is necessary in some special case, follow the instructions below. Please make sure your AC unit is completely powered off before performing any type of maintenance. 1.2 – Safety Warnings When reading this manual, note these icons: Notes with this icon MUST be read, understood, and obeyed to prevent injury or damage etc. Notes with this icon include relevant information. 1. After turning off the RolliCool, unplug it. 2. If needed, remove the Drainage Pipe’s stopper and drain the water down away from the unit. Using a bucket is recommended. 3. To completely dry the inside, use Fan Only Mode for at least two hours. 4. If the Drainage Pipe needs an extension, materials to do so can be purchased at most hardware stores. Drainage 6.4 – How to Clear Water from Drainage Pipe If the Drainage Pipe has excessive water that needs to be cleared, follow the instructions below. Please make sure your AC unit is completely powered off before performing any type of maintenance. Step 1. Unplug the unit and remove the Indoor Unit from the wall. Step 2. Place the unit on a sturdy surface and remove the Coupler Cover. Step 3. Use needle nose pliers to pinch the Drainage Pipe’s metal clasp to release the pipe from the unit. Step 4. Clear the water from the Drainage Pipe. Step 5. Connect the Drainage Pipe back to the unit and push the clasp around the pipe where it is connected to the unit. Step 6. Use needle nose pliers to fix the metal clasp back in place. Step 7. Replace the cover, add and tighten the screw, and place the unit back on the wall. Overall Usage • Do not insert objects into the product. • The product is not a toy. Do not leave children unsupervised around the product. • The product is designed for indoor use only. • Keep the product upright at all times. • Do not use the product near any of the following places: • Near anything flammable • Direct sunlight • Damp areas • Dusty areas • Do not use wax, thinner, or solvents when cleaning the air conditioner. • Clean your filter once or more every couple of weeks. • Do not place any obstacles in front of the inlet. • Do not pull the power lines. • In the event that the product is malfunctioning, shut the power off immediately. • Switch off the product before cleaning. • If used in homes near saltwater locations, the unit may be subject to accelerated corrosion. • You should only use parts you have received from RolliBot™ or that have been included in the original packaging. • Do not use the product for any purpose other than described in this user manual. 1.3 – Installation Warnings INDOOR UNIT • Do not install the indoor unit in a sloped setting. • Do not install the indoor unit in direct sunlight. 20 Rollibot-MiniSplitAC-UM-0403.indd Spread 5 of 12 - Pages(20, 5) RolliBot RolliCool Mini-Split AC User Manual RolliBot RolliCool Mini-Split AC User Manual 4/10/2017 7:41:19 PM • • • • • Do not install in places with open flames or flammable gas. Do not use extension cords etc. Only plug the indoor unit into a grounded wall outlet. Install in clear area without any obstructions nearby. Avoid installing the indoor unit in damp areas. Install near the wall with space to link the coolant lines between the indoor and outdoor unit. • When a schedule is active, the unit will not turn on if the chosen temperature is higher than the indoor temperature. TO SET A SHUTOFF TIME OUTDOOR UNIT • • • • • Never install the outdoor unit in a place where the product is likely to fall. Make sure to drain the outdoor unit with the drainage pipe. Do not install the outdoor unit in direct sunlight. Do not install the outdoor unit near open flames or by flammable gas. Do not install the outdoor unit in extremely windy areas. 1.4 – FCC Information DECLARATION OF CONFORMITY: 1. When the unit and remote are on, press the Timer Button on the Control Panel or the remote. This device complies with Part 15 of the FCC Rules. 2. Use the Up and Down Buttons to select the time the AC unit will turn off i.e. selecting “03” will prompt the unit to turn off in 3 hours’ time etc. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC RELATED INFORMATION: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 3. After the selection is complete, the display will show the current indoor temperature and the Schedule Light. Section 6. Maintenance Proper maintenance will help improve your RolliCool’s performance. The RolliCool will periodically need its filter cleaned. For optimal performance, the filters should be cleaned at least twice a month. It is also recommended to regularly inspect the Drainage Pipe. If any type of non-routine maintenance is needed, such as any maintenance not described in Section 6 of this manual, please contact customer service or a certified HVAC professional as the unit contains refrigerant. 6.1 – How to Clean the Filters • • • • Please make sure your AC unit is completely powered off before performing any type of maintenance. Do not scrape the air filters as it may sustain damage. A hand vacuum or low-powered vacuum or vacuum modes may be used to clean the filters. Replace the filters after cleaning. Do not use the RolliCool without the filters. • Consult the dealer or an experienced radio/TV technician for help. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. 1. Pull off the front panel. 2. Pull out the filter. 1.5 – Disposal at End-of-Life This product must not be disposed of by incineration, landfilling, or mixing with household trash. Improper disposal of the battery contained within this product may result in the battery heating up, rupturing, or igniting which may cause serious injury. The refrigerants contained inside the RolliCool present chemical risks to the environment. The recommended disposal for any RolliCool Portable Air Conditioner at its end-of-life is to dispose of the entire unit by contacting your local recycling company. Local regulations and laws pertaining to the recycling Rollibot-MiniSplitAC-UM-0403.indd Spread 6 of 12 - Pages(6, 19) RolliBot RolliCool Mini-Split AC User Manual RolliBot RolliCool Mini-Split AC User Manual 19 4/10/2017 7:41:19 PM and disposal of any RolliCool unit and/or products containing them will vary according to your country, state, and local governments. You must check laws and regulations corresponding to where you live in order to dispose of your RolliCool unit properly. It is the user’s responsibility to dispose of their equipment properly in accordance with local regulations and laws. 5.4 – Fan Only Mode With this mode, the unit will turn on and begin using the fan to promote air circulation. For additional information about where you should drop off your RolliCool unit, please contact your local or regional waste management office, your household waste disposal service, or your point-of-sale. 2.1 – Box Contents Section 2. RolliCool Parts • • • • • 1. Press the Power Button on the Control Panel or the remote. 2. Press the Mode Button on the Control Panel until the Fan Only Mode icon appears. Or simply press the Fan Only Button on the remote. 1 x RolliCool Mini-Split AC (Indoor Unit) 1 x RolliCool Mini-Split AC (Outdoor Unit) 1 x Remote Control 2 x Air Filter (pre-installed) 4 x Wall Anchors/Screws • 1 x Window Kit 3. Use the Fan Speed Button to change fan speed. Press it multiple times to cycle through 3 fan speeds. In Fan Only Mode, the fan speed is automatically set low and cannot be adjusted. 5.5 – Timer With this mode, the unit will automatically turn on or off and regulate temperature according to the selected times. • • RolliCool Mini-Split AC COOL-P800 (Indoor Unit) Window Kit RolliCool Mini-Split AC COOL-P800 (Outdoor Unit) Setting the schedule when the unit is off means setting the time the unit will turn on. Setting the schedule when the unit is on means setting the time the unit will run before it shuts off. Wall Anchors/Screws TO SET A TURN ON TIME Remote Control 2.2 – Components Overview INDOOR UNIT 1 Front Panel 2 Air Filter 3 Handle 4 Control Panel 5 Remote 6 Air Outlet 7 Coolant Lines 1. When the unit and remote are off, press the Timer Button on the Control Panel or the remote. 2. Use the Up and Down Buttons to select the time the AC unit will turn on i.e. selecting “03” will prompt the unit to turn on in 3 hours’ time etc. Rollibot-MiniSplitAC-UM-0403.indd Spread 7 of 12 - Pages(18, 7) 9 Coupler Cover RolliBot RolliCool Mini-Split AC User Manual 11 10 Drainage Pipe 11 Power Cord 3. After the selection is complete, the display will show the Timer icon. 18 8 Mount Openings RolliBot RolliCool Mini-Split AC User Manual 10 4/10/2017 7:41:19 PM 5.2 – Cooling Mode OUTDOOR UNIT With this mode, the unit will turn on and regulate temperature as selected. 1 Handle 2 Air Outlet 3 Coolant Lines 4 Condensation Outlet 5 Coupler 2.3 – Control Panel 1. Press the Power Button on the Control Panel or the remote. The RolliCool Mini-Split AC features an LED Control Panel which lights up when the AC unit turns on and includes buttons. Auto Mode Light Celsius Light Cool Mode Light Fahrenheit Light Dehumidify Mode Light Schedule Light Fan Only Mode Light Fan Speed Light 2. Press the Mode Button on the Control Panel until the Cool Mode light turns on. Press it multiple times to cycle through different modes. Or simply press the Cool Button on the remote. 3. Use the Up and Down Buttons to set the desired temperature between 61~88°F (16~310C ). 4. Use the Fan Speed Button to change fan speed. Press it multiple times to cycle through 3 fan speeds. When Cool Mode is active, the unit will not turn on if the chosen temperature is higher than the indoor temperature. 5.3 – Dehumidify Mode With this mode, the unit will turn on and begin removing moisture from the air. Power Button Mode Fan Speed Down Button Button Button Up Button CONTROL PANEL LIGHTS Auto. Mode: This icon will light up when the unit is in Auto Mode. Cool Mode: This icon will light up when the unit is in Cool Mode. Dehumidify Mode: This icon will light up when the unit is in Dehumidify Mode. Fan Only Mode: This icon will light up when the unit is in Fan Only Mode. 1. Press the Power Button on the Control Panel or the remote. Celsius: If selected, this icon will light up when the current temperature is being 2. Press the Mode Button on the Control Panel until the Dehumidify Mode icon appears. Press it multiple times to cycle through different modes. Or simply press the Dehumidify Button on the remote. displayed. Rollibot-MiniSplitAC-UM-0403.indd Spread 8 of 12 - Pages(8, 17) In Dehumidify Mode, the fan speed is automatically set low and cannot be adjusted. RolliBot RolliCool Mini-Split AC User Manual RolliBot RolliCool Mini-Split AC User Manual 17 4/10/2017 7:41:35 PM Section 4. App Setup Fahrenheit: If selected, this icon will light up when the current temperature is For your convenience, there is an app for the RolliCool. The app is compatible with most Android and iOS smartphones. The app can be used to set cooling schedules, change modes, and more. Use your smartphone to search the Play or App Store for the “RolliCool” application then download and install the app according to your operating system. After downloading the app, see the steps and images below to use it and connect to your AC unit. For your convenience, the steps have been divided into parts. being displayed. • Either wi-fi or Bluetooth® may be used for setup. It is not necessary to set up via both methods. • Powering on the RolliCool will automatically enable Bluetooth® i.e. Bluetooth® will become enabled and stay enabled as long as the RolliCool is turned on. • For instructions on how to turn on Bluetooth®, consult materials for your Bluetooth®-enabled smartphone. • As with most Bluetooth® devices, it is recommended to keep the connected devices at least 32 ft. within each other. The connection may be terminated or fail to work properly if the connected devices are too far apart. Section 5. How to Use the RolliCool Schedule: This icon will light up when a schedule has been programmed. Fan Speed: This icon will light up and change according to the selected fan speed. CONTROL PANEL BUTTONS Power Button: Press to turn the unit on or off. Mode Button: Press to cycle between Auto, Cool, Dehumidify, and Fan Only modes. Fan Speed Button: Press to cycle between 3 fan speeds. The RolliCool Mini-Split AC features a number of ways to keep cool and comfortable. Most features can be used by pressing the buttons on the unit’s Control Panel, the remote, or via the app. Down Button: Press to lower temperature. Up Button: Press to raise temperature. In most cases where the remote can be used, the app can also be used as a substitute. • Scheduling can be done and/or adjusted via the Control Panel, remote, or the app. See the following section for more information about the remote. See Section 4 for information about the app. 5.1 – Auto Mode With this mode, the unit will turn on and regulate temperature as selected. 1. Press the Power Button on the Control Panel or the remote. 2. Press the Mode Button on the Control Panel until the Auto Mode light turns on. Press it multiple times to cycle through different modes. Or simply press the Auto Button on the remote. 3. Use the Up and Down Buttons to set the desired temperature between 61~88°F (16~310C ). • When Auto Mode is active, the unit will not turn on if the chosen temperature is higher than the indoor temperature. • In Auto Mode, the fan speed is automatically set and cannot be adjusted. 16 Rollibot-MiniSplitAC-UM-0403.indd Spread 9 of 12 - Pages(16, 9) RolliBot RolliCool Mini-Split AC User Manual RolliBot RolliCool Mini-Split AC User Manual 4/10/2017 7:41:36 PM 2.4 – Remote Overview 3.4 – Separating the Coupler The RolliCool Mini-Split AC features a remote which may be used with the unit. If needed, the Indoor and Outdoor Units can be disconnected from one another in case any adjustments or maintenance is needed. Before separating the coupler from the unit, turn off the RolliCool, disconnect it from any power supply and wait at least 5 minutes. REMOTE BUTTONS Never separate the coupler while the unit is on. Power Button: Press to turn the unit on or off. Auto Button: Press to turn on Auto Mode. Cool Button: Press to turn on Cool Mode. Dehumidify Button: Press to turn on Dehumidify Mode. Power Cable Fan Only Button: Press to turn on Fan Only Mode. Cover Schedule Button: Press to turn on Schedule Mode. Keep the Coolant Lines straight Latch Up Button: Press to raise temperature or adjust schedule duration. Step 1. Step 2. Down Button: Press to lower temperature or adjust schedule Unscrew the screw at the right side of the cover. Push the button at the right side of the cover and pull it away from the unit to remove it. Slowly open the latch and hold the Coolant Lines so that they’re straight. Note, the unit may emit a chugging sound due to the refrigerant; this is normal. duration. Fan Speed Button: Press to cycle between 3 fan speeds. °C/°F Button: Press to switch between Celsius and Fahrenheit. • • • • • Avoid pressing two buttons simultaneously as this may cause malfunctions. Avoid using the remote in areas with extreme temperature fluctuations. If the remote will not be used for extended periods of time, remove the battery. The remote control’s range is approximately 23 ft. Use it within this range. The remote uses one CR2 (CR2035 3V) battery. This battery is included. Rubber Cap Before Using the Remote Pull the tab to remove the protective film. 10 Rollibot-MiniSplitAC-UM-0403.indd Spread 10 of 12 - Pages(10, 15) To Change the Battery Step 3. Step 4. Disconnect the power cable from the inside of the unit. Lift the Coolant Lines up and away from the unit to remove it. Insert the rubber stopper into the end of the Coupler to prevent leakage. Pull part A in towards the remote then pull part B out to remove the battery tray. Remove any dead battery and replace with a new battery, + side up. RolliBot RolliCool Mini-Split AC User Manual RolliBot RolliCool Mini-Split AC User Manual 15 4/10/2017 7:41:36 PM 3.3 – Connecting the Coupler Section 3. Setting Up the AC 3.1 – Installing the Indoor Unit Power Cable • Choose a mounting location situated next to a window as the Coolant Lines must be run through a window in order to keep the Indoor and Outdoor Units connected. • Using a stud detector for detection and installation into wall studs may be desired for more secure mounting. Cover Keep the Coolant Lines straight Step 1. Step 2. Unscrew the screw at the right side of the cover. Push the button at the right side of the cover and pull it away from the unit to remove it. Remove the rubber stopper from the end of the Coupler if it is installed. Open the latch and line the Coupler up with its connectors. Step 1. Choose a suitable location on the wall for mounting the unit. Step 2. Measure between the Mount Openings on the back of the unit. Step 3. Mark locations on the wall according to the openings. Step 4. Use a drill to make 4 holes at each of the marks. Step 5. Insert the Wall Anchors into the wall. Step 6. Add the screws into their anchors making sure a length of 4mm~9mm is left out of the wall. Step3. Step 4. Make sure the Coupler is properly threaded into its connectors and push it straight down. Slowly close the latch, taking care to use even pressure on the latch. Step 7. Install the Indoor Unit onto the wall making sure the notches in the Mount Openings slide over the screws. Step 8. Check to ensure the Indoor Unit is securely installed on the wall. Step 9. Remove the Indoor Unit for now to prepare for connection. After installing the Outdoor Unit (Section 3.2) and Connecting the Coupler (Section 3.3), reinstall the Indoor Unit on the wall. Step 5. Step 6. Connect the power cable to the inside of the unit. Replace the Coupler Cover. Make sure to add the screw. Ensure that the rubber stopper is placed in a suitable location. If the Indoor and Outdoor Units are disconnected e.g. when the unit is being moved, the rubber stopper should be reinstalled into the end of the Coupler. If separating the two, review the following section. 14 Rollibot-MiniSplitAC-UM-0403.indd Spread 11 of 12 - Pages(14, 11) RolliBot RolliCool Mini-Split AC User Manual RolliBot RolliCool Mini-Split AC User Manual 11 4/10/2017 7:41:36 PM 3.2 – Installing the Outdoor Unit In order to let off exhaust and hot air, the Outdoor Unit should be placed on level, stable ground outdoors. The Coolant Lines must be used to connect the two units and may be routed through a window with the help of the Window Kit. Please read all installation steps and parts instructions and information before attempting to install. WINDOW KIT PARTS Screw Head Washer Screw Base SECTIONS CONNECTOR SCREW FASTENER These sections thread into one another and should be placed within a window gap. A may be flipped so that the opening is higher or lower. This piece is later inserted into the opening in Section A and used to hold the Coolant Lines in place. These parts are used to secure the sections together and can be loosened or tightened when adjusting the sections according to window height. Step 4. Step 5. Step 6. Thread Section C onto the other end of Section B and use the Screw Head and Washer to secure the sections together. Separate one Screw Fastener and thread the Screw Base into one end of the second Section B. Thread the second Section B into the other end of Section C and use the Screw Head and Washer to secure the sections together. INSTALLATION Step 1. Step 2. Step 3. Separate one Screw Fastener and thread the Screw Base into one end of Section B. Thread Section A onto the end of Section B and use the Screw Head and Washer to secure the sections together. Repeat Step 1 one at the other end of Section B. 12 Rollibot-MiniSplitAC-UM-0403.indd Spread 12 of 12 - Pages(12, 13) Step 7. Step 8. Step 9. Thread the Coolant Lines into the side of the Connector then fit the Connector into Section A making sure the notch is in place. Check that all Sections are connected like so. Install the assembled kit into a window gap and push the window nearly closed to secure it in place. Use the fasteners to adjust as needed. Screw Fasteners RolliBot RolliCool Mini-Split AC User Manual RolliBot RolliCool Mini-Split AC User Manual 13 4/10/2017 7:41:36 PM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Trapped : False Producer : Acrobat Distiller 10.1.1 (Windows) Creator Tool : Adobe InDesign CC 2017 (Windows) Modify Date : 2017:06:15 14:25:14+08:00 Create Date : 2017:04:10 19:41:52-07:00 Metadata Date : 2017:06:15 14:25:14+08:00 Thumbnail Width : 256 Thumbnail Height : 188 Thumbnail Format : JPEG Thumbnail Image : (Binary data 11053 bytes, use -b option to extract) GTS PDFX Conformance : PDF/X-1a:2001 GTS PDFX Version : PDF/X-1:2001 Version ID : 1 Rendition Class : proof:pdf Document ID : uuid:2279c417-39f4-4fda-bd41-d615bedcbe01 Instance ID : uuid:434d0fa3-ec1f-4a6f-81d4-14946ee44a11 Format : application/pdf Title : Rollibot-MiniSplitAC-UM-0403.indd Creator : Susan N Pages : 1 Has Visible Transparency : False Has Visible Overprint : True Max Page Size W : 325.966667 Max Page Size H : 237.066667 Max Page Size Unit : Millimeters Font Name : MinionPro-Regular, MyriadPro-CondIt, MyriadPro-BoldSemiCn, MyriadPro-Regular, MyriadPro-Bold, MyriadPro-BlackCond Font Family : Minion Pro, Myriad Pro, Myriad Pro, Myriad Pro, Myriad Pro, MyriadPro BlackCond Font Face : Regular, Condensed Italic, Bold SemiCondensed, Regular, Bold, BlackCond Font Type : Open Type, Open Type, Open Type, Open Type, Open Type, Unknown Font Version : Version 2.108;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.037;PS 2.000;hotconv 1.0.51;makeotf.lib2.0.18671, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, Version 5.016;PS 5.006;hotconv 1.0.67;makeotf.lib2.5.33168 Font Composite : False, False, False, False, False, False Font File Name : MinionPro-Regular.otf, MyriadPro-CondIt.otf, MyriadPro-BoldSemiCn.otf, MyriadPro-Regular.otf, MyriadPro-Bold.otf, AdobeHeitiStd-Regular.otf Plate Names : Cyan, Magenta, Yellow, Black Swatch Groups Group Name : 默认色板组 Swatch Groups Group Type : 0 Page Count : 12 Author : SusanEXIF Metadata provided by EXIF.tools