3M Scott Technologies 201122A X3 SEMS + BT User Manual 595289 01 A

Scott Safety-Division of Scott Technologies, Inc. X3 SEMS + BT 595289 01 A

Users Manual B Draft Rev

Page 1 of 36P/N 595289-01 Rev B  5/15OPERATION AND MAINTENANCE INSTRUCTIONSSEMS II SCOTT ELECTRONIC MANAGEMENT SYSTEMUSER PERSONAL DISTRESS ALARM AND USER ACCOUNTABILITY SYSTEM FOR THE SCOTT AIR-PAK X3 SELF-CONTAINED BREATHING APPARATUSSEMS II CONSOLE ON AIR-PAK X3 SCBAWARNINGTHE SCOTT SEMS II PERSONAL DISTRESS ALARM AND USER ACCOUNTABILITY SYSTEM IS INTENDED FOR USE WITH SCOTT SELF-CONTAINED BREATHING APPARATUS (SCBA) WHICH MAY SUPPORT HUMAN LIFE IN HAZARDOUS ATMOSPHERES. FAILURE TO CAREFULLY READ AND UNDERSTAND THE FOLLOWING INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH TO THE SCBA USER.USE OF A RESPIRATOR INTEGRATED WITH THE SEMS II / BLUETOOTH USER ACCOUNTABILITY SYSTEM WILL REQUIRE MODIFICATION OF THE RESPIRATOR "REGULAR OPERATIONAL INSPECTION PROCEDURES" AND WILL REQUIRE TRAINING OF THE RESPIRATOR USER IN THE USE OF SUCH RESPIRATORS.THE FOLLOWING INSTRUCTIONS SUPPLEMENT BUT DO NOT REPLACE THE OPERATING AND MAINTENANCE INSTRUCTIONS SUPPLIED WITH EACH RESPIRATOR.© 2015 Scott Safety. SCOTT, the SCOTT SAFETY Logo, Scott Health and Safety, SEMS II, PAK-ALERT, PAK-TRACKER, AIR-PAK, and NxG are registered and/or unregistered marks of Scott Technologies, Inc. or its afliates.DRAFT COPY - NOT FOR PUBLICATION IMPERIUM ACCOUNTABILITY BASE STATION (SHOWN  WITH REQUIRED PERSONAL  COMPUTER, NOT INCLUDED)WARNINGTHIS PRODUCT IS DESIGNED AND INTENDED TO FUNCTION PROPERLY IN REASONABLE/ORDINARY FIREFIGHT-ING CONDITIONS. IT HAS BEEN CERTIFIED TO THE STANDARDS CONTAINED IN THE 2013 EDITION OF NFPA 1982. LIKE ALL EQUIPMENT, THE FUNCTIONALITY OF THIS PRODUCT MAY BE COMPROMISED BY EXTREME FIRE CONDITIONS.PRELIMINARY DRAFT - NOT FOR PUBLICATION
Page 2 of 36P/N 595289-01 Rev B   5/15WARNINGDO NOT OPERATE THIS EQUIPMENT WHILE UN-DER THE INFLUENCE OF DRUGS, ALCOHOL, OR ANY MEDICATIONS OR SUBSTANCES WHICH MAY AFFECT VISION, DEXTERITY, OR JUDG-MENT. USERS OF THIS EQUIPMENT MUST BE IN GOOD PHYSICAL AND MENTAL HEALTH IN ORDER TO OPERATE SAFELY. DO NOT USE THIS EQUIPMENT WHEN FATIGUE PREVENTS SAFE OPERATION. STAY ALERT WHEN OPERATING THIS EQUIPMENT. INATTENTION OR CARELESS-NESS WHILE OPERATING THIS EQUIPMENT MAY RESULT IN SERIOUS INJURY OR DEATH.SYSTEM DESCRIPTIONSEMS II ACCOUNTABILITY SYSTEMThe SCOTT Electronic Management System (SEMS II) is a respirator user  accountability system that provides communication between respirator users in a hazardous area and an incident commander or other designated person outside of the hazardous area. The SCOTT SEMS II Personal Distress Alarm (PDA) is an optional accessory. It is intended to be integrated only with a compatible SCOTT self-contained breathing apparatus (SCBA) such as the AIR-PAK SCBA. The installation of the SCOTT SEMS II Personal Distress Alarm is approved by the National Institute of Occupational Safety and Health (NIOSH) on specic models of SCOTT SCBA. The complete SCOTT Emergency Management System (SEMS) consists of:•  The Personal Alert Safety System (PASS) on the SCBA to sound a loud alarm when the user is motionless for a short period of time;•  The IMPERIUM software with computer Base Station monitoring the status of SCBA users, including air supply levels, PASS activation, and evacuation calls. –Max. of 150 SCBAs using SEMS II –Max. of 50 SCBAs using BLUETOOTH® backup•  The PAK-TRACKER Locator System to locate the transmitted signal from a SEMS II Personal Distress Alarm (PDA) Portable Unit where PASS has been activated.The complete IMPERIUM ACCOUNTABILITY SYSTEM consists of:•  Individual transmitting SEMS II (or SEMS II with a BLUETOOTH backup) enabled portable unit with Control Consoles integrated into to the SCOTT self-contained breathing apparatus; •  Programmable ID Tags and programming equipment, (Tags are available in a variety of forms); •  A Personal Computer (not included) with IMPERIUM software installed;•  Receiver(s) to capture transmitted SEMS II and BLUETOOTH  signals to personal computer. Refer to the SCOTT CONNECT IMPERIUM ACCOUNTABILITY BASE STATION SOFTWARE Installation and Use instructions, SCOTT P/N 595290-01, in the HELP directory of the IMPERIUM software for a complete listing of all equipment available for the IMPERIUM ACCOUNTABILITY SYESTEM. All items are sold separately.SEMS II equipped PDA Portable Units provide a continuous limited two-way communication between the SCBA respirator control console and  X3 AIR-PAK SCBA WITH SEMS II DISTRESS ALARM ASSEMBLYSEMS II CONTROL CONSOLE ASSEMBLYSENSOR MODULE ASSEMBLY SEMS IISCOTT ELECTRONIC MANAGEMENT SYSTEMPERSONAL DISTRESS ALARM AND BASE STATIONNOTEUSE IN ACCORDANCE WITH NFPA 1500, "STANDARD ON FIRE DEPARTMENT OCCUPATIONAL SAFETY AND HEALTH PROGRAM."The BLUETOOTH trademarks are owned by BLUETOOTH SIG, Inc. Other trademarks and trade names in this document are those of their respective owners. © 2013 BLUETOOTH SIG, Inc. Subject to change without prior notice.MOTOROLA and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC.
Page 3 of 36P/N 595289-01 Rev B  5/15WARNINGNO PERSONAL ALERT SAFETY SYSTEM, RESPIRATOR OR COMBINATION OF PERSONAL ALERT SAFETY SYSTEM AND RESPIRATOR, BY THEMSELVES, CAN PROVIDE COMPLETE PROTECTION IN DANGEROUS SITUATIONS. FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL AND THE REQUIREMENTS OF AN ORGANIZED RESPIRATORY PROTECTION PROGRAM MAY LEAD TO SITUATIONS WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.WARNINGUSERS OF RESPIRATORS EQUIPPED WITH THE SEMS II DISTRESS ALARM MUST BE AWARE OF THE PROPER OPERATION OF THE DISTRESS ALARM. IF THE GREEN LIGHT IS NOT FLASHING NORMALLY, OR IF THE UNIT EXHIBITS ANY OTHER SIGNS OF A MALFUNCTION WITHOUT THE USER TAKING PROPER CORRECTIVE ACTION, IT MAY LEAD TO CIRCUMSTANCES THAT RESULT IN SERIOUS INJURY OR DEATH.SYSTEM DESCRIPTION CONTINUED ON NEXT PAGE...SEMS II PERSONAL DISTRESS ALARM CONTROL CONSOLEThe SCOTT SEMS II PDA Portable Unit, when added to a SCOTT SCBA respirator consists of a Sensor Module with battery compartment mounted to the bottom of the respirator backframe, a pressure gauge with transducer, and a Control Console mounted on the wearer’s right shoulder strap at the pressure gauge location. The SEMS II PDA Portable Unit requires six (6) AA batteries to operate the Sensor Module on the backframe. The SEMS II PDA Control Console is integrated into the SCOTT SCBA as a part of the remote air pressure gauge assembly which hangs over the right shoulder of the respirator user. The Control Console also operates the PERSONAL ALERT SAFETY SYSTEM (PASS) distress alarm intended to as-sist in locating a respirator user who is incapacitated or in need of assistance. The PASS distress alarm in this model reaches FULL ALARM in a total of 30 (thirty) seconds. The Control Console has a set of status lights, a dial air pres-sure gauge, and three control buttons which can easily be pressed with gloved hands. Power is supplied by batteries in the SEMS II PDA battery compartment on the SCBA backframe.WARNINGFOLLOW REGULAR OPERATIONAL INSPECTION PROCEDURE EXACTLY. IF THE SEMS II DISTRESS ALARM DOES NOT ACTUATE, OR IF ANY OTHER FEATURE  DOES NOT OPERATE AS DESCRIBED OR IF ANY OTHER OPERATIONAL MALFUNCTION IS NOTED, DO NOT USE THE RESPIRATOR.WARNINGTHE SEMS II ACCOUNTABILITY SYSTEM COMMUNICATES ONLY WITH FIREFIGHTER RESOURCES (RESPIRATOR USERS) USING A SCOTT SCBA EQUIPPED WITH THE SEMS II ACCOUNTABILITY SYSTEM INTEGRATED INTO THE PERSONAL DISTRESS ALARM. OTHER FIREFIGHTER RESOURCES WHO ARE NOT USING A PROPERLY EQUIPPED SCOTT RESPIRATOR MAY BE ADDED FOR ACCOUNT-ABILITY PURPOSES, BUT THEY WILL NOT BE AUTOMATICALLY ACCESSIBLE THROUGH THE COMMUNICATIONS FUNCTIONS OF THE SYSTEM. FAILURE TO RECOGNIZE THE STATUS OF FIREFIGHTER RESOURCES MAY RESULT IN SERIOUS INJURY OR DEATH.the IMPERIUM software. When logged on, all the SEMS II PDA Portable Units  communicate to the Base Station directly and/or through other logged on units forming a communications "mesh network" to the Base Station. This extends the range for the units furthest away from the Base Station. Because of this mesh network system, the signal strength of each user may change as the network constantly re-adjusts to the movement of the users.SCBAs addtionally equipped with an optional BLUETOOTH backup communication, provide a limited one-way transmission from the control console to the Base Station at one minute intervals via a APX™ RF Modem/ Radio network. No information can be transmitted back to the respirator user when transmitting in BLUETOOTH mode.In units equipped with both SEMS II and BLUETOOTH, the SEMS II is the primary mode of communication between the console and Base Station. BLUETOOTH will only transmit information via radio to the base station when the SEMS II is out of range or otherwise unable to link to the system. Once the SEMS II transmission has resumed, or the SCBA is turned off, the BLUETOOTH transmission will discontinue.SEMS II CONTROL CONSOLESAIR-PAK X3 MODEL   CONSOLENOTESEMS II ENABLED PDA UNITS HAVE BIDIRECTIONAL COMMUNICATION CAPABILI-TIES AND CAN BOTH TRANSMIT AND RECEIVE DATA BETWEEN THE PDA AND THE BASE STATION. WHEN IN BLUETOOTH MODE, BLUETOOTH ENABLED PDA CONTROL CONSOLES ARE UNIDIRECTIONAL ONLY. THEY CAN SEND DATA TO THE BASE STATION THROUGH APPROVED BLUETOOTH ENABLED  PORTABLE TWO-WAY RADIOS BUT CANNOT RECEIVE DATA BACK FROM THE BASE STATION.No personal alert safety system, respirator, or combination of personal alert safety system and respirator, by themselves, can provide complete protection in dangerous situations. However, using an alarm and a respirator in accordance with the require-ments of an organized respiratory protection program is one of the many safety precautions which should be taken to avoid personal injury or death.These instructions explain the operation and use of the main functions of the ac-countability system. Follow the REGULAR OPERATIONAL INSPECTION procedure as described. If any function fails to operate as described, do not use the equipment. Remove the unit from service and tag for repair by authorized personnel. This system communicates only with Fireghter Resources (Respirator Users) using a SCOTT SCBA equipped with the SEMS II Accountability System integrated into the Personal Distress Alarm. Complete training in the use of the SEMS II and Bluetooth equipment is required before actual use in a hazardous envirionment. If the equipment does not work as described in these instructions, remove the equipment from service and tag for repair by authorized personnel.
Page 4 of 36P/N 595289-01 Rev B   5/15SYSTEM DESCRIPTION CONTINUED...EXAMPLE OF IMPERIUM BASE STATION SCREEN DISPLAYSEMS II ACCOUNTABILITY SYSTEM BASE STATIONThe base station consists of a IMPERIUM  Accountability Software, USB Gateway or PCMCIA card SEMS II receiver, and/or optional APX RF Modem receiver installed on a Windows1 based Personal Computer (not included). SCOTT recommends use of a laptop computer designed for rugged use. Refer to the SCOTT CONNECT IMPERIUM ACCOUNTABILITY BASE STATION SOFTWARE Installation and Use instructions, SCOTT P/N 595290-01, in the HELP directory of the IMPERIUM software for complete system specication details, set up and operation. With the Imperium Event Management Software running on the PC, the incident com-mander has current information about status of the respirator users who are logged onto the Base Station, including information about air supply levels and PASS activa-tion. Simple dedicated functions in the software control the transmission to (SEMS II only) and receipt of signals from (SEMS II and BLUEtootth) respirator users. The same computer can be used for programming the ID Tags used with the SEMS II PDA. 1 WINDOWS  is a registered trademarks of MICROSOFT CORPORATION, Redmond, WashingtonSEMS II BASE STATION WITH USB GATEWAY INSTALLED ON  A LAPTOP PERSONAL COMPUTERWARNINGAUDIBLE ALARMS WILL ONLY SOUND FROM THE BASE STATION WHILE BASE STATION COMPUTER SPEAKERS ARE TURNED ON. MUTING THE SPEAKERS WILL RENDER THE BASE STATION ALARMS SILENT. BASE STATION COMMANDER MUST NOT MUTE THE BASE STATION SPEAKERS DURING AN ACTIVE EVENT. FAILURE TO MONITOR AND RESPOND TO AN ACTIVE ALARM COULD LEAD TO SERIOUS INJURY OR DEATH.APX RF MODEM
Page 5 of 36P/N 595289-01 Rev B  5/15When a respirator user opens the cylinder valve and begins use of a SCOTT SCBA equipped with the SEMS II PDA, the Accountability System electronics will automati-cally begin to operate. If the IMPERIUM Base Station is present at time of entry the SEMS II PDA will attempt to log-in to the Base Station. BLUETOOTH enabled units will attempt to log-in to the Base Station once the paired radio is turned on and they are communicating. When the SEMS II is out of range or otherwise unable to link to the system, the BLUETOOTH information will display on the base station. Once the SEMS II transmission has resumed, or the SCBA is turned off, the BLUETOOTH display will discontinue. It is the responsibility of the Incident Commanders from each re company to coordinate activities with each other and to maintain accountability for all participating reghter resources.Multiple organizations with SEMS II Accountability System equipment can operate at a single event scene since each Base Station operator can select and monitor which users log in on their Base Station. Multiple base stations may also be used at a single event to manage resources from several different re companies. SEMS II users will appear in one base station at a time. The user can be rejected and connect to an alternate base station. BLUETOOTH signats transmit to a base station modem via radio.  The BLUETOOTH users will simultaneously appear on ALL base stations that are congured to the same radio channel. BLUETOOTH units will continue to display on the base station screen until the PDA unit either re-establishes SEMS II communication or it is turned off and removed from the base station. The SEMS II Accountability System and Personal Distress Alarm can be quickly pro-grammed with the identication of the SCBA user using the SEMS II Accountability RFID Tag, Badge, or Button. Programming the ID Tags and Portable Units allows the organization to customize the identication of the SEMS II Portable Units. See SEMS II Programming Guide, SCOTT Imperium Commissioning for complete details of programming the SEMS II equipment. SCOTT recommends re-programming with the RFID card in accordance with your organization's procedures to assure that the user's unique ID number is in use at all times.SYSTEM DESCRIPTION CONTINUED ON NEXT PAGE...PROGRAMMING THE USER ID WITH THE RFID TAG ID ICONSEMS II RFID TAG WRITER, SCOTT P/N 200773-01.
Page 6 of 36P/N 595289-01 Rev B   5/15PAK-TRACKER LOCATOR SYSTEMThe SCOTT PAK-TRACKER Locator System is a two part electronic system consisting of a PAK-TRACKER Transmitter integrated into the SCOTT SEMS II distress alarm, and a PAK-TRACKER Hand Held Receiver, which is a directional receiver used to locate the signal coming from the PAK-TRACKER Transmitter. The PAK-TRACKER locator system transmitter is activated with the PASS alarm. The transmitter emits a radio signal with a unique ID number that can be tracked using the SCOTT PAK-TRACKER Hand Held Receiver unit. The PAK-TRACKER Hand Held Receiver is then used as a directional receiver to assist in leading the rescue team to the activated transmitter. By pointing the PAK-TRACKER Hand Held Receiver in the direction of the strongest relative signal, the rescue crew can follow the signal toward the respirator user who is incapacitated or in need of assistance.Use of this equipment must be part of a complete personnel accountability system that includes procedures for monitoring the deployment and condition of all users. Do not rely on the PAK-TRACKER Locator System as the only technique for locating miss-ing personnel. Failure to use this equipment properly may actually increase the time needed to locate and rescue personnel. TRAINING AND PRACTICE IN REALISTIC EMERGENCY SIMULATIONS IS REQUIRED BEFORE USE OF THIS EQUIPMENT. The users must become thoroughly familiar with the operation and the limitations of the locator system before entering a potentially hazardous or life threatening situation.The PAK-TRACKER Locator System User Instructions, SCOTT part number 595102-01, contain essential information on the use of the locator system and must be used as the basis of training for use of the whole system including use with a SEMS II distress alarm equipped with the PAK-TRACKER Transmitter. The PAK-TRACKER Locator System User Instructions include an overview of the system operation, limitations of the system, as well as any user level maintenance for the PAK-TRACKER Locator System equipment. Copies of the PAK-TRACKER Locator System User Instructions are available from your SCOTT distributor or from SCOTT Safety.All User Instructions are provided on the software CD in Adobe  Acrobat 2 format (pdf). You may download a free copy of Adobe Acrobat Reader from www.Adobe.com/Acrobat Reader.PAK-TRACKER HAND HELD RECEIVERWARNINGREAD AND UNDERSTAND THIS ENTIRE MAN-UAL AND THE PAK-TRACKER LOCATOR SYSTEM MANUAL, P/N 595102-01. TRAINING IS REQUIRED BEFORE USE OF THIS EQUIPMENT IN A HAZARDOUS SITUATION. THE TRAINING MUST INCLUDE AN UNDERSTANDING OF THE LIMITATIONS OF THE EQUIPMENT AND HOW TO INTERPRET LOCATING INFORMATION, ALONG WITH EXTENSIVE PRACTICE WITH THE SYSTEM IN A VARIETY OF ENVIRONMENTS. USE OF THIS EQUIPMENT MUST BE A PART OF A COMPLETE PERSONNEL ACCOUNTABILITY SYSTEM. ALWAYS UPDATE TRAINING WITH EACH NEW PIECE OF EQUIPMENT. USE OF A PAK-TRACKER LOCATOR SYSTEM WITHOUT PROPER TRAIN-ING MAY PLACE THE USERS AT HIGHER RISK IN DANGEROUS SITUATIONS WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.SYSTEM DESCRIPTION CONTINUED...2 Adobe and Adobe Acrobat are registered trademarks of Adobe Systems, San Jose, California
Page 7 of 36P/N 595289-01 Rev B  5/15DATA LOGGING FEATURERespirators equipped with a SCOTT SEMS II distress alarm integrated PASS device are compliant to NFPA 1982, 2013 Edition. The PASS device includes on-board electronics which maintain a running log of event data including start-up, shut-down, and PASS activation. The SCOTT DATA LOGGER Computer Interface is required to access the information. Instructions for downloading the data log are SCOTT P/N 595123-01 and are included with the computer interface.RETROFITTED UNITSInstallation of the SCOTT SEMS II Personal Distress Alarm requires some disassem-bly of the respirator and should only be performed by an authorized service center. Respirators already equipped with an approved SCOTT X3 Distress Alarm integrated PASS device may be retrotted with the SEMS II Accountability System Control Con-sole. However, if the PAK-TRACKER Transmitter was NOT enabled on the original X3 Distress Alarm, this will have to be enabled by a SCOTT Authorized Service Center to receive the full functionality described in these instructions.Contact SCOTT Safety, Monroe, NC at 1-800-247-7257 for complete details.Report any operational malfunctions of the PASS function of this device to the certication agency Safety Equipment Institute (SEI), 1307 Dolley Madison Blvd. Suite 3A, McLean, VA 22101, (703) 442-5732, FAX (703) 442-5756.QUESTIONS OR CONCERNSIf you have any questions or concerns regarding use of this equipment, contact your authorized SCOTT distributor, or contact SCOTT at 1-800-247-7257 (or 704-291-8300 outside the continental United States) or visit our web site at www.scottsafety.com.
Page 8 of 36P/N 595289-01 Rev B   5/15WARNINGTHE INFORMATION BELOW IS MEANT TO SUPPLEMENT, NOT REPLACE, THE TRAINING, SUPERVISION, MAINTENANCE, AND OTHER ELEMENTS OF YOUR ORGANIZED RESPIRATORY PROTECTION PROGRAM. SEE WARNING ON FIRST PAGE OF THIS DOCUMENT. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH.WARNINGUSERS OF RESPIRATORS EQUIPPED WITH THE SEMS II DISTRESS ALARM MUST BE AWARE OF THE PROPER OPERATION OF THE DISTRESS ALARM. FAILURE TO RECOGNIZE A MALFUNCTION OF THE SEMS II DISTRESS ALARM AND TAKE PROPER CORRECTIVE ACTION MAY RESULT IN SERIOUS INJURY OR DEATH.OPERATION AND USE OF THE SEMS II DISTRESS ALARM (PASS)ACTIVATIONPrepare the respirator for use according to the user instructions provided with the respirator. Install the batteries in the SEMS II Sensor Module according to the BAT-TERY INSTALLATION section of this instruction.The SEMS II distress alarm device is automatically activated when the respirator is pressurized by opening the cylinder valve of the respirator. To indicate activation, the sensor module will sound 3 quick audible chirps and the green light located on the control console will ash approximately once every three (3) seconds. The SEMS II distress alarm is now in sensing mode.Once activated, the SCOTT SEMS II distress alarm constantly monitors motion of the respirator backframe. The sensor module is located on the respirator backframe beneath the air cylinder and contains the motion sensor and the audible alarm. If the sensor module does not sense motion of the respirator for twenty (20) seconds, the SEMS II distress alarm will signal a pre-alarm condition. If there is still no motion of the respirator for the next twelve (12) seconds the full alarm will sound.The SCOTT SEMS II distress alarm will remain activated until turned OFF according to these instructions.THE CONTROL CONSOLE(PRESSURE GAUGE DEPENDS ON SYSTEM PRESSURE)RESET BUTTON(YELLOW BUTTON)MANUAL ALARM BUTTON(RED BUTTON)CONSOLEDISPLAYWITHDRAW BUTTON (GRAY BUTTON)EXTERNAL-HEADS UP DISPLAY (HUD)AIR-PAK X3 MODEL CONSOLEPASS  SIGNAL LIGHT
Page 9 of 36P/N 595289-01 Rev B  5/15WARNINGUSERS OF RESPIRATORS EQUIPPED WITH THE SEMS II DISTRESS ALARM MUST BE AWARE OF THE PROPER OPERATION OF THE DISTRESS ALARM. FAILURE TO RECOGNIZE A MALFUNCTION OF THE SEMS II DISTRESS ALARM AND TAKE PROPER CORRECTIVE ACTION MAY RESULT IN SERIOUS INJURY OR DEATH.PRE ALARM:If the respirator remains motionless for more than twenty (20) seconds, the SEMS II distress alarm will automatically sound a pre-alarm When the pre-alarm occurs, the green ashing light on the control console is replaced by  alternating  bright  red  lights  which  ash  approximately  once  a  second  and  are accompanied by an ascending/descending audible tone which increases in volume during the pre-alarm cycle. If the respirator user is not incapacitated or not in need of assistance, move the respi-rator to reset the pre-alarm. When reset, the ashing red light will be replaced by the ashing green and the ascending/descending tone will stop. Remember that the motion sensor is in the sensor module on the respirator backframe beneath the air cylinder. Actual movement of the respirator backframe is required to re-set the pre-alarm. Shaking the control console will not reset the SEMS II distress alarm .To manually reset the pre-alarm, press and hold the reset button on the side of the control console until three (3) quick audible chirps are heard and the red ashing light on the control console is replaced by the green ashing light.FULL ALARM:If the respirator remains motionless through the twelve (12) second pre-alarm cycle, the SEMS II distress alarm will go into full alarm. This may indicate that the user is incapacitated or in need of assistance and can not move.Full alarm is indicated by a loud alarm tone from the sensor module accompanied by simultaneous ashing red signal lights on the control console.  After an additional (10) second delay, the unit will send a notication of PASS activation to the SEMS II Base Station and the Pak-Tracker Locator transmitter in the unit will begin transmitting the unique ID number that can be received by the Pak-Tracker Hand Held Unit.  To reset the full alarm condition, press the reset button twice. After the full alarm has been silenced, the SEMS II distress alarm will remain activated in sensing mode with the green light ashing once per second. As long as the respirator is pressurized, there must be movement of the respirator at least every twenty (20) seconds or the distress alarm will again go into pre-alarm followed by full alarm as described above.MANUAL ALARM:If the respirator user requires immediate assistance, pressing the manual alarm button located on the front of the control console will immediately sound the full alarm. The manual alarm may be activated at any time, even when the respirator is not pressurized. The manual alarm is indicated by a loud alarm tone from the sensor module accom-panied by simultaneous ashing red signal lights on the control console. The unit will immediately send a notication of PASS activation to the SEMS II Base Station and the Pak-Tracker Locator transmitter in the unit will begin transmitting the unique ID number that can be received by the Pak-Tracker Hand Held Unit. . To reset the manual alarm, press the reset button twice. After the alarm has been silenced, the SEMS II distress alarm will remain activated in sensing mode.To turn the unit off, press the reset twice again while the unit is not in alarm mode.Remember, the loud audible alarm and ashing red light can be turned on at any time by pressing the manual alarm button on the control console.TO TURN OFF THE SEMS II DISTRESS ALARMWhen use of the respirator with the SEMS II distress alarm is no longer required, close the cylinder valve on the respirator and vent the residual air from the respirator system by opening the regulator purge valve. After all the air ow stops, press the reset button twice to turn off the distress alarm and close the regulator purge valve.If there is no pressure in the system when the RESET button is pressed twice, the unit will sound a quick two tone chirp to indicate that the alarm has been turned off. If there is air pressure left in the system when the RESET button is pressed twice, the sensor module will allow fteen (15) seconds to for the residual air to bleed from the system. .A green light will ash and sensor will beep for fteen (15) seconds. Once the air has completely bled from system, the unit will sound the quick two tone chirp to indicate that the alarm has been turned off. If pressure remains in the respirator after the fteen (15) seconds and/or the respirator cylinder valve remains open, alarm sensor WILL NOT turn off and the distress alarm will return to sensing mode. OPERATION AND USE OF THE SEMS II DISTRESS ALARMCONTINUED ON NEXT PAGE...
Page 10 of 36P/N 595289-01 Rev B   5/15If the respirator cylinder is turned off and depressurized without rendering the alarm sensor inactive (pressing the RESET button twice), the distress alarm will continue to monitor motion in sensing mode. This means that the distress alarm may be used to monitor motion after the respirator is turned off and depressurized. Resetting the full alarm after the respirator has been depressurized will not turn off the distress alarm. After resetting the full alarm, press the RESET switch twice with no alarm condition to turn off the distress alarm.LOW BATTERYIn a low battery condition, the SEMS II distress alarm will produce a single audible chirp from the sensor module once every two (2) seconds and the green light on the control module will not ash. In low battery condition, the SEMS II distress alarm will not emit the 3 beeps when cylinder valve is activated.While in low battery condition, the SEMS II distress alarm will continue to operate for a period of time greater then the longest duration cylinder available for the respirator. However, the batteries must be replaced before the respirator is used again. See the BATTERY REPLACEMENT section of these instructions.If batteries are completely discharged or have not been installed, there will be no light or sound and the unit will not operate.BATTERY TESTWhen the SEMS II PDA is in the off condition (cylinder valve closed with no ashing lights, the batteries in the entire system can be checked by depressing and holding the RESET button on the console.•  A GREEN LED will illuminate on the Control Console, if there is sufcient bat-tery power remaining,•  A RED LED indicates that the batteries are low and must be replaced before the respirator is to be used again.If a low battery message occurs, ALL batteries must be changed before the respirator is used again. See the BATTERY REPLACEMENT section of this instruction for details.WARNINGDO NOT USE A RESPIRATOR IN A LOW BATTERY CONDITION. FAILURE TO REPLACE THE BATTERIES AND/OR CONTINUING WITH MULTIPLE USES OF THE RESPIRATOR AFTER THE LOW BATTERY CONDITION HAS BEEN INDICATED BY THE SEMS II DISTRESS ALARM MAY RESULT IN FAILURE OF THE SEMS II DISTRESS ALARM DURING USE AND POSSIBLE INJURY OR DEATH OF THE USER.OPERATION AND USE OF THE SEMS II DISTRESS ALARMCONTINUED...DATA LOGGING FEATUREThe SEMS II Distress Alarm PASS device includes on-board electronics which maintain a running log of event data including start-up, shut-down, and PASS activation. The SCOTT DATA LOGGER Computer Interface is required to access the information. Instructions for downloading the data log are SCOTT P/N 595123-01 and are included with the computer interface.Use of the SCOTT DATA LOGGER Computer Interface will remove the programmed RFID card number and will automatically return to the default ID number.
Page 11 of 36P/N 595289-01 Rev B  5/15CONSOLE BUTTONSThere are three (3) buttons on the Control Console. They are as follows:MANUAL ALARM  Red  To activate the PASS alarm manuallyWITHDRAW  Gray  To signal withdraw and scan ID card RESET  Yellow  Used for various functions.CONSOLE DISPLAYThe Console Display has four (4) ICON Symbol segments that light in response to specic conditions. The four are:EVACThe EVAC symbol (Running Man) lights when either the Base Sta-tion sends a call to the user(s) to  EVACUATE (ashed RED), or the user presses the WITHDRAW Button on the Control Console (ashes YELLOW).  Base Station call to evacute will not transmit to PDA when communicating via BLUETOOTH.RANGEThe RANGE symbol lights when the user is out of range of the Base Station (SEMS II) or the APX radio (BLUETOOTH). The Base Station displays a similar message.  PASS ALARMThe PASS ALARM symbol lights when the user’s PASS is activated. The Base Station displays a similar message.IDThe ID symbol is used to indicate the ID programming mode and that the input from the user’s Accountability Tag has been accepted.OPERATION AND USE OF ACCOUNTABILITY SYSTEM WARNINGTRAINING IS REQUIRED BEFORE USE OF THIS EQUIPMENT IN A HAZARDOUS SITUATION. USE OF THIS EQUIPMENT MUST BE A PART OF A COMPLETE INCIDENT MANAGEMENT AND PERSONNEL ACCOUNTABILITY SYSTEM PROGRAM. THE TRAINING MUST INCLUDE AN UNDERSTANDING OF THE LIMITATIONS OF THE EQUIPMENT ALONG WITH EXTENSIVE PRACTICE WITH THE SYSTEM IN A VARIETY OF ENVIRONMENTS. ALWAYS UPDATE TRAINING WITH EACH NEW PIECE OF EQUIPMENT. USE OF THE SEMS II ACCOUNTABILITY SYSTEM WITHOUT PROPER TRAINING MAY PLACE THE USERS AT HIGHER RISK IN DANGEROUS SITU-ATIONS WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.The following section describes the features of the SEMS II Accountability System. Training is required before use of this equipment. Use of this equipment must be part of a complete incident management and personnel accountability program. WARNINGTHE SEMS II ACCOUNTABILITY SYSTEM COMMUNICATES ONLY WITH FIREFIGHTER RESOURCES (RESPIRATOR USERS) USING A SCOTT SCBA EQUIPPED WITH THE SEMS II ACCOUNTABILITY SYSTEM INTEGRATED INTO THE PERSONAL DISTRESS ALARM. OTHER FIREFIGHTER RESOURCES WHO ARE NOT USING A PROPERLY EQUIPPED SCOTT RESPIRATOR MAY BE ADDED FOR ACCOUNT-ABILITY PURPOSES, BUT THEY WILL NOT BE ACCESSIBLE THROUGH THE COMMUNICA-TIONS FUNCTIONS OF THE SYSTEM. FAILURE TO RECOGNIZE THE STATUS OF FIREFIGHTER RESOURCES MAY RESULT IN SERIOUS INJURY OR DEATH.THE CONTROL CONSOLERESET BUTTON(YELLOW BUTTON)MANUAL ALARM BUTTON(RED BUTTON)CONSOLEDISPLAYWITHDRAW BUTTON (GRAY BUTTON)EXTERNAL-HEADS UP DISPLAY (HUD)PASS  SIGNAL LIGHTAIRPRESSURE GAUGEOPERATION AND USE OF THE ACCOUNTABILITY SYSTEM CONTINUED ON NEXT PAGE...NOTESEMS II ENABLED PDA UNITS HAVE BIDIRECTIONAL COMMUNICATION CAPA-BILITIES AND CAN BOTH TRANSMIT AND RECEIVE DATA BETWEEN THE PDA AND THE BASE STATION. BLUETOOTH ENABLED PDA CONTROL CONSOLES ARE UNIDIRECTIONAL ONLY. THEY CAN SEND DATA TO THE BASE STATION THROUGH APPROVED BLUETOOTH ENABLED PORTABLE TWO-WAY RADIOS BUT CANNOT RECEIVE DATA BACK FROM THE BASE STATION.BLUETOOTH LED LIGHT (BLUE)
Page 12 of 36P/N 595289-01 Rev B   5/15PROGRAMMING A UNIT WITH AN RFID TAGSCOTT recommends re-programming with the RFID card in accordance with your organization's procedures to assure that the user's unique ID number is in use at all times. To program the identication of a SEMS II Portable unit with an RFID Tag, proceed as follows:1.  Verify that the air cylinder is closed and there is no residual air in the system.2.  Verify that the electronics have been inactive for at lease thirty (30) seconds.3.  On the Control Console, hold down the GRAY (Withdraw) button until the ID light goes on. Release the button. 4.  Within ten (10) seconds, hold your SEMS II ID Tag against the back of the Control Console labeled "SCAN ID TAGS HERE." 5.  To indicate the programming has been successful, the ID light will ash three (3) times slowly then go out.6.  When performing the REGULAR OPERATIONAL INSPECTION of the SEMS II Accountability System, verify that the correct ID appears on the Base Station display.NOTEONCE THE RESPIRATOR HAS BEEN PRESSURIZED FOR USE, THE ID CANNOT BE CHANGED. THE RESPIRATOR MUST BE SHUT DOWN AND THERE MUST BE NO RESIDUAL AIR PRESSURE LEFT IN THE SYSTEM TO CHANGE THE ID.To manually remove the programmed RFID card number, verify that the air cylinder is closed, there is no residual air in the system, and the PASS is in the off state. Press and hold the YELLOW RESET Button for eight (8) seconds. During reset, the red lights on the PASS console will alternately ash and SEMS II Distress Alarm Pass device will attempt to interface with Data Logger computer. Additionally, the unit will automatically return to the default ID number:–  if the battery cover is opened and/or the batteries are removed,   OR–  after twenty-four (24) hours.PRESSING THE GRAY (WITHDRAW) BUTTONPROGRAMMING THE USER ID WITH THE RFID TAG ID LIGHT WILL FLASH 3  TIMES SLOWLY TO INDICATE SUCCESSFUL PROGRAMOPERATION AND USE OF ACCOUNTABILITY SYSTEM CONTINUED...
Page 13 of 36P/N 595289-01 Rev B  5/15OPERATION AND USE OF THE ACCOUNTABILITY SYSTEM CONTINUED ON NEXT PAGE...OPERATION AND USE OF PDA PORTABLE CONTROL CONSOLE UNITSUsers of SCOTT respirators equipped with the SEMS II (and optional BLUETOOTH enabled PDA) Control Consoles must be fully trained in the operation of the equipment as part of a complete respiratory protection program before entering a hazardous environment.Start-up•  SEMS II: Use of the SEMS II enabled unit begins when the user rst opens the cylinder valve on the respirator. The unit will sound three chirps to indicate activation. After a brief start-up sequence, the module will sound 3 quick audible chirps and  a  green  light  located  on  the  control  console  will  ash approximately once a second. • BLUETOOTH: Use of the BLUETOOTH transmission begins when a unit communicates with a previously paired compatible portable two-way radio. Refer to the "PAIRING BLUETOOTH ENABLED PDA CONTROL CONSOLE WITH PORTABLE TWO-WAY RADIO" section of this instruction for pairing instruction. To start the connection turn on the radio. Then, open the cylinder. The LED light on the X3 console will begin ashing BLUE as the PDA searches for the paired radio. 2.  Initialization and RANGE•  SEMS II: After the start-up sequence, the SEMS II PDA Por-table Unit will send an Initialization signal to the base stationa.  When a SEMS II is searching for a connection to the base station, the RANGE symbol on the Control Console will flash YELLOW.b.  When a connection is made with the base station, the RANGE symbol on the Control Console will turn to solid GREEN c.  When a SEMS II respirator user loses contact with the base sta-tion, the RANGE symbol on the Control Console will flash YELLOW indicating out of range until it can regain contact. If using a dual SEMS II and BLUETOOTH unit, the BLUETOOTH may connect until SEMS II is back in range.•  BLUETOOTH: a.  When a Bluetooth connection is made to the two way radio the LED on the PDA unit will light solid Blue. b.  When the SCBA user moves too far from the radio after logging-in, the LED will flash BLUE until it is back in range.Except for those functions which involve communication all PASS functions of the Control Console and PDA distress alarm are still operational when the Portable Unit is either out of range or not connected to a base station or radio. 3.  PASS DISTRESS ALARMa.  The SEMS II PDA PASS distress alarm will operate in conjunc-tion with the Portable Unit. If the distress alarm on the respirator is activated, either by the user pressing and holding the Red MANUAL ALARM button for at least two seconds, or from the user being immobile for the required time duration, the Portable Unit will send a PASS distress alarm signal to the base station. This signal will override all other messages and actions of the Portable Unit. The PASS symbol on the Control Console will flash RED. (SEMS II and Bluetooth)b.  The PASS icon will appear Flashing RED on the Console, and an audible alert will sound. (SEMS II and Bluetooth)c.  When the base station acknowledges the user’s distress signal by selecting the TEAM Member's PASS button on the TEAM Details, the PASS symbol on the Control Console will turn Solid RED. (SEMS II ONLY)d.  The distress alarm on the respirator will continue until the user shuts down the respirator or resets the alarm.RANGEPASSEVAC WITHDRAWRANGE PASS IDCONTROL CONSOLE ICONSAIR-PAK X3SIGNALLIGHTSRESETBUTTON(YELLOW)MANUAL ALARM BUTTON(RED)WITHDRAW BUTTON (GRAY)CONTROL CONSOLEDISPLAYPDA PORTABLE CONTROL CONSOLEBLUETOOTH LED LIGHT (BLUE)
Page 14 of 36P/N 595289-01 Rev B   5/154.  EVACUATION (SEMS II ONLY)a.  If the respirator users are required to leave the hazardous area, the base station operator can send an evacuation message to the Portable Units of logged-in respirator users. This message can be sent either to all logged-in users (EVAC ALL), to everyone on an Assignment (EVAC ASSIGN), to everyone in a geographic DIVISION (EVAC BLDG) or to an individual logged-in users as selected from the TEAM Details (EVAC). b.  The Portable Unit will emit the alert sound and the EVAC symbol will begin flashing RED on the Control Console.c.  When an EVAC symbol begins flashing on the Control Console, the respirator user must press twice the Yellow RESET button on the Control Console to respond to the evacuation message. The EVAC symbol on the Control Console will turn ON solid RED until the user leaves the hazardous area and shuts down the respirator. The res-pirator user's EVAC symbol in the TEAM Details on the Display will change from RED to WHITE to indicate acknowledgement.Evacuation message will ONLY be sent to individual SEMS II PDA users or to the QUEUE interface. EVAC notice will not send to user while in BLUETOOTH mode but will send once SEMS II communications have resumed. EVAC button will be deactivated when no SEMS II Gateway is connected to the Base Station.5.  WITHDRAWa.  The respirator user may choose to leave the hazardous area. Pressing and holding the Gray WITHDRAW button for at least two seconds will send that message to the Base Station. The "EVAC" symbol on the Control Console will ash YELLOW quickly as the WITHDRAW message appears on the Base Station. b.  When the Base Station receives a user WITHDRAW message, the Base Station Operator selects the ACK W/D button.c)  After the Base Station acknowledges, the “EVAC” symbol on the Control Console will turn ON steady until user leaves hazardous area and shuts down the respirator.6.  Air Supply Cylinder Pressurea)  In addition to the other end-of-service indicators on the respirator, when the cylinder reaches one third of full pressure, the VIBE ALERT sounds a LOW AIR warning with an audible alarm. .b)  The VIBE ALERT alarm will be transmitted until the respirator has been de-pleted. This LOW AIR alarm is in addition to the other end-of-service indicators on the respirator.7.  Shutdowna)  After leaving the hazardous  area  and conrming that respirator use is no longer required, doff the respirator according the user instructions provided with the respirator.b)  Close the cylinder valve. Use the purge valve to release all the residual air pressure in the system.c)  Press the Yellow RESET button twice.d)  The Control Console will sound the alert tone. The SEMS II PDA Portable Unit is now off.EVAC/WITHDRAWWARNINGTHE RESPIRATOR USER MUST IMMEDI-ATELY LEAVE THE AREA REQUIRING RE-SPIRATORY PROTECTION WHEN AN END OF SERVICE INDICATOR ALARM ACTU-ATES. ACTUATION OF AN END OF SER-VICE INDICATOR ALARM WARNS THAT APPROXIMATELY 1/3 OF FULL PRESSURE REMAINS IN THE AIR SUPPLY CYLINDER (THAT IS, APPROXIMATELY 2/3 OF THE TOTAL AIR SUPPLY HAS BEEN USED). A DELAY IN LEAVING THE AREA AFTER ALARM ACTUATION MAY CAUSE DEPLE-TION OF BREATHING AIR SUPPLY WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.BASE STATION OPERATIONThe SEMS II Base Station consists of a SEMS II Accountability System Base Station installed in a Windows based Personal Computer, preferably a laptop (not included). SCOTT recommends use of a laptop computer designed for rugged use. Refer to the SCOTT CONNECT IMPERIUM ACCOUNTABILITY BASE STATION SOFTWARE Installation and Use instructions, SCOTT P/N 595290-01, in the HELP directory of the IMPERIUM software for complete details of computer requirements, Base Station software setup, and use of the Accountability System.The IMPERIUM Base Station must be operated by a fully trained individual as part of a complete incident management system and respiratory protection program. The Base Station Operator must have the ability to notify other personnel if an emergency situation develops as displayed by the SEMS II Accountability System.OPERATION AND USE OF ACCOUNTABILITY SYSTEM CONTINUED...WARNINGAUDIBLE ALARMS WILL ONLY SOUND FROM THE BASE STATION WHILE BASE STATION COMPUTER SPEAKERS ARE TURNED ON. MUTING THE SPEAKERS WILL RENDER THE BASE STATION ALARMS SILENT. BASE STATION COMMANDER MUST NOT MUTE THE BASE STATION SPEAKERS DURING AN ACTIVE EVENT. FAILURE TO MONITOR AND RESPOND TO AN ACTIVE ALARM COULD LEAD TO SERIOUS INJURY OR DEATH.EVAC/WITHDRAW
Page 15 of 36P/N 595289-01 Rev B  5/15WARNINGDO NOT TAKE THE BASE STATION INTO A FIRE OR INTO A POTENTIALLY FLAMMABLE OR EX-PLOSIVE ATMOSPHERE. OPERATE THE BASE STATION ONLY IN A SAFE AREA AWAY FROM THE HAZARDOUS ATMOSPHERE WHERE THE RESPIRATORS ARE BEING USED. USE OF THE BASE STATION IN A POTENTIALLY FLAMMABLE OR EXPLOSIVE ATMOSPHERE MAY CAUSE IG-NITION OF THE ATMOSPHERE WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.WARNINGTHE IMPERIUM ACCOUNTABILITY SYSTEM COMMUNICATES ONLY WITH FIREFIGHTER RESOURCES (RESPIRATOR USERS) USING A SCOTT SCBA RESPIRATOR EQUIPPED WITH THE IMPERIUM ACCOUNTABILITY SYSTEM INTEGRATED INTO THE PERSONAL DISTRESS ALARM. OTHER FIREFIGHTER RESOURCES WHO ARE NOT USING A PROPERLY EQUIPPED SCOTT RESPIRATOR MAY BE ADDED FOR ACCOUNTABILITY PURPOSES, BUT THEY WILL NOT BE AUTOMATICALLY ACCESSIBLE THROUGH THE COMMUNICATIONS FUNC-TIONS OF THE IMPERIUM SYSTEM. FAILURE TO RECOGNIZE THE STATUS OF FIREFIGHTER RESOURCES MAY RESULT IN SERIOUS INJURY OR DEATH.WARNINGTHE IMPERIUM ACCOUNTABILITY BASE STATION MUST BE MONITORED BY A FULLY TRAINED INDIVIDUAL WITH THE ABILITY TO DIRECT RESCUE OPERATIONS AT ALL TIMES WHEN LOGGED-IN RESPIRATOR USERS MAY BE IN A HAZARDOUS AREA. FAILURE TO PROVIDE A PROPERLY TRAINED BASE STATION OPERATOR MAY PERMIT A SITUATION TO OCCUR WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.PASSEVAC/WITHDRAW RANGEPRIMARY FUNCTIONS OF THE SOFTWAREIMPERIUM software is designed for both tactical and strategic event management with compliance to NIMS and the user’s own organizational standard operating guidelines (SOG’s).The software is not SCBA specic and is designed to be used also by rst responders.The primary purpose of the IMPERIUM is to monitor the activities of Accountability System users, including active SEMS II PDA (Personal Distress Alarm) users and Queue Accessory users, as well as Non-SEMS II PDA users (by use of RFID Tags to log into the system) and Equipment.The software is a TEAM Based approach to event management based on dened ASSIGNMENTS and TEAMS placed on those assignments. Each Event can be new or can be based on a customized set of parameters set in an EVENT template. The Application Settings can also be preset to control the way the Software displays and/or processes the information provided to the The IMPERIUM Base Station Operator. The primary functions of the software are as follows:1.  Open an EVENT.2.  Create ASSIGNMENTS for TEAMS.3.  ASSIGN Individual Resources to ASSIGNMENTS and TEAMS (and/or DIVISIONS depending on the nature of the event.)4.  REJECT Individual Resources (active SEMS II PDA users, Bluetooth enabled PDA users, NON-SEMS II PDA users and Equipment only.)5.  REMOVE Assignments, TEAMS, DIVISIONS, or Individuals from the event.6.  MONITOR the condition of active SEMS II and Bluetooth enabled PDA users and take the appropriate actions.7.  Create NOTES for the event.8.  Provide a REPORT of the event.Active SEMS II PDA users can send signals to and receive signals from the base station. When in BLUETOOTH mode, PDA users can send signals to the base sta-tion but cannot receive them from the base station. The base station operator can perform the following tasks:MONITOR ALERTS for:•  LOW AIR SUPPLY of each active SEMS II and BLUETOOTH enabled PDA user.•  PASS Activation (either automatic and manual activation) of each active SEMS II and BLUETOOTH enabled PDA user.•  OUT-OF-RANGE – Shows the status of the communication link from each User’s active SEMS II PDA (or QUEUE Interface) to the base station. (SEMS II and QUEUE only)•  WITHDRAW Notication from each active SEMS II and BLUETOOTH enabled PDA users.Send an EVACUATION (EVAC) Signal when required (SEMS II PDA USERS ONLY):•  EVAC ALL – Evacuate all logged in active SEMS II only.•  EVAC TEAM – Evacuate a TEAM of logged in active SEMS II only.•  EVAC ASSIGNMENT– Evacuate by ASSIGNMENT of logged in active SEMS II only.•  EVAC BLDG – Evacuate by DIVISION of logged in active SEMS II only.•  EVAC IND – Evacuate an Individual active SEMS II PDA users only. NOTESEMS II PDA UNITS AND QUEUE ACCESSORIES CAN INITIALLY TAKE APPROXIMATELY FORTY (40) SECONDS TO TWO (2) MINUTES TO CONNECT TO THE BASE STATION. CONNECTION TIME MAY INCREASE AS THE NUMBER OF ADDITIONAL NODES (EXTERNAL DEVICES) INCREASES.NOTEIF A PDA UNIT HAS BOTH SEMS II AND BLUETOOTH CAPABILITIES, THE SEMS II WILL TRANSMISSIONS WILL ALWAYS TAKE PRECEDENCE AND APPEAR AS A SEMS II USER ON THE BASE STATION. THE BLUETOOTH TRANSMISSION WILL ONLY APPEAR AS A BLUETOOTH USER IF THE SEMS II TRANSMISSION CANNOT CONNECT TO THE BASE STATION.BASE STATION OPERATION CONTINUED ON NEXT PAGE...
Page 16 of 36P/N 595289-01 Rev B   5/15WARNINGDO NOT TAKE THE BASE STATION INTO A FIRE OR INTO A POTENTIALLY FLAMMABLE OR EXPLOSIVE ATMOSPHERE. OPERATE THE BASE STATION ONLY IN A SAFE AREA AWAY FROM THE HAZARDOUS ATMOSPHERE WHERE THE RESPIRATORS ARE BEING USED. USE OF THE BASE STATION IN A POTENTIALLY FLAMMABLE OR EXPLOSIVE ATMOSPHERE MAY CAUSE IGNITION OF THE ATMOSPHERE WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.WARNINGTHE IMPERIUM ACCOUNTABILITY SYSTEM COMMUNICATES ONLY WITH FIREFIGHTER RESOURCES (RESPIRATOR USERS) USING A SCOTT SCBA RESPIRATOR EQUIPPED WITH THE IMPERIUM ACCOUNTABILITY SYSTEM INTEGRATED INTO THE PERSONAL DISTRESS ALARM. OTHER FIREFIGHTER RESOURCES WHO ARE NOT USING A PROPERLY EQUIPPED SCOTT RESPIRATOR MAY BE ADDED FOR ACCOUNTABILITY PURPOSES, BUT THEY WILL NOT BE AUTOMATICALLY ACCESSIBLE THROUGH THE COMMUNICATIONS FUNC-TIONS OF THE IMPERIUM SYSTEM. FAILURE TO RECOGNIZE THE STATUS OF FIREFIGHTER RESOURCES MAY RESULT IN SERIOUS INJURY OR DEATH.The EVAC/WITHDRAW, PASS, and RANGE icons that appear on the software display are the same as the EVAC/WITHDRAW, PASS, and RANGE symbols that appear on the PDA Control Console display.When active SEMS II PDA Users are logged into the system and included in the event activities (moved to the MAIN TACTICAL DISPLAY), they must be part of a TEAM and the TEAM must be associated with an ASSIGNMENT. As two individuals are as-sociated with each other, they appear as a TEAM with ability to designate one of the members as TEAM LEADER. If any member of a TEAM transmits an alert (PASS, LOW AIR, or OUT-OF-RANGE), the TEAM icon on the screen will indicate RED and an audible alarm will sound. The Alert information for the individual is available through the TEAM Details.When an ASSIGNMENT has been created and an individual is placed on the TACTI-CAL VIEW Display Screen, that person will be labeled TEAM 1 and associated with the current ASSIGNMENT. A TEAM should consist of a minimum of two (2) people. If another individual is placed on the TACTICAL VIEW Display Screen but not associ-ated with an existing TEAM, that individual will be labeled TEAM 2.Additional functions include:1.  Accountability for Support Personnel (Non-SEMS II PDA Users by use of RFID Tags to log into the system).2.  Personnel Accountability Report (PAR) Timer reminder can be set according to your standard procedures.3.  Event Report to provide an account of event information.NOTEACCESSIBILITY TO SOME SETTINGS MAY BE LIMITED BY YOUR SYSTEM ADMINISTRATOR TO MAINTAIN COMPLIANCE WITH APPLICABLE NATIONAL STANDARDS OR ESTABLISHED INTERNAL PROCEDURES.TRAINING REQUIRED BEFORE USE. Refer to the SCOTT CONNECT IMPERIUM ACCOUNTABILITY BASE STATION SOFTWARE Installation and Use instructions, SCOTT P/N 595290-01, in the HELP directory of the IMPERIUM software for complete details on the use of the IMPERIUM Accountability Base Station System.BASE STATION OPERATION CONTINUED...
Page 17 of 36P/N 595289-01 Rev B  5/15BASE STATION OPERATOR RESPONSIBILITIESThe base station Operator must create and track ASSIGNMENTS.The base station operator must monitor and respond to any ACTIVE ALERTS in accordance with the organization’s event management program. This may include issuing an EVAC signal to the individual or to the entire TEAM.Monitor for the following TEAM MEMBER ACTIVE ALERTS including:•  LOW AIR  – When the air supply cylinder reaches predetermined pressure, the end-of-service-time indicators (EOSTI) will activate on the SCBA and a LOW AIR signal will be sent to the base station. The TEAM Icon will ash RED, the "Team Summary" will show a red bar, the team member image of effected individual in the "Teammate Details" will display a red bar and the base station will sound the LOW AIR audible alarm.• PASS – When a User's PASS has been activated, the TEAM Icon will ash RED, the "Team Summary" will show a red bar, the team member image of effected individual in the "Teammate Details" will display a red bar and PASS icon, and the base station will sound the PASS audible alarm. These alarms will continue until the PASS has been turned off on the PDA unit. •  OUT OF RANGE –The OUT OF RANGE caution will begin after forty (40) seconds without a signal from the SEMS II PDA User or the QUEUE interface to the Base Station, or two (2) minutes without transmission from BLUETOOTH enabled PDA  to  the APX  Radio.  The  TEAM  Icon  will  ash YELLOW,  the  "Team Summary" will show a yellow bar, the team member image in "Teammate Details" will display a Yellow bar and Out of Range icon, and the base station will sound the Out of Range caution audible alarm indicating the system is trying to re-link with the user. –If re-linking does NOT occur, the TEAM Icon will ash RED, the "Team Sum-mary" will show a Red bar, the team member image in "Teammate Details" will display a Red bar and Out of Range icon, and the base station will sound the Out of Range audible alarm The base station operator must respond to the User’s out of RANGE signal in accordance with the organization’s event management program.•  WITHDRAW – An individual TEAM Member chooses to WITHDRAW by pressing the GRAY (or BLUE) button on the User’s Control Console on the SCBA. When this occurs, the WITHDRAW message is sent to the base station. The TEAM Icon will ash  RED, the "Team Summary" will show a red bar, the  team member image of effected individual in the "Teammate Details" will display a red bar and WITHDRAW icon, and the base station will sound the WITH-DRAW audible alarm. PAR CALL AND RESPONSE•  Support Personnel Accountability (Non-SEMS II PDA users by use of RFID Tags to log into the system). – The base station operator must monitor and coordinate the activities of Non-SEMS II PDA users who have logged into the system by the use of RFID Tags in accordance with the organization’s event management program.ALARM ICONSOut of RangeEvacuateEvacuation AcknowledgedWithdrawWithdraw AcknowledgedPASS AlarmPASS Alarm AcknowledgedWARNINGAUDIBLE ALARMS WILL ONLY SOUND FROM THE IMPERIUM BASE STATION WHILE WORKING WITHIN AN OPEN EVENT. NAVIGATION TO ANY OTHER SCREEN WILL RENDER THE ALARMS AT THE IMPERIUM BASE STATION SILENT. THE IMPERIUM BASE STATION COMMANDER MUST NOT NAVIGATE TO OTHER SCREENS DURING AN ACTIVE EVENT. FAILURE TO MONITOR AND RESPOND TO AN ACTIVE ALARM COULD LEAD TO SERIOUS INJURY OR DEATH.WARNINGSEMS II PDA UNITS AND THE QUEUE ACCES-SORY WILL ONLY CONNECT TO THE IMPERIUM BASE STATION WHILE WORKING WITHIN AN OPEN EVENT. NAVIGATION TO ANY OTHER SCREEN WILL TEMPORARILY DISCONNECT THESE DEVICES AND THEIR ALARMS. UPON RETURN TO THE EVENT, THE DEVICES WILL HAVE TO REESTABLISH A CONNECTION AND WILL NOT SHOW ANY VISUAL OR AUDIBLE ALARMS FOR APPROXIMATELY 2 MINUTES UNTIL CONNECTION IS REESTABLISHED. COMMANDER MUST NOT NAVIGATE TO OTHER SCREENS DURING AN ACTIVE EVENT. FAILURE TO MONITOR AND RESPOND TO AN ACTIVE ALARM COULD LEAD TO SERIOUS INJURY OR DEATH.
Page 18 of 36P/N 595289-01 Rev B   5/15USE AS PART OF AN ACCOUNTABILITY SYSTEMTRAINING REQUIRED BEFORE USE. Refer to the PAK-TRACKER Locator Sys-tem User Instructions, SCOTT P/N 595102-01 for complete details on the use of the PAK-TRACKER Locator System. Use of this equipment must be part of a complete personnel accountability system that includes procedures for monitoring the deploy-ment and condition of all users. Do not rely on the PAK-TRACKER Locator System as the only technique for locating missing personnel. A Rapid Intervention or Rescue team using the Hand Held Receiver must have a minimum of two (2) people. For their own safety, the team members must pay attention to their surroundings at all times while using the PAK-TRACKER Locator System.The accountability system must include procedures for alerting the incident commander and rescue teams when actuated transmitters or the missing personnel have been found or when they have moved from their previous location. It is the responsibility of the personnel accountability system to allow for such contingencies without exposing individuals and teams to unnecessary dangers.PRINCIPLES OF OPERATION OF THE PAK-TRACKER LOCATOR SYSTEMThe SCOTT PAK-TRACKER locator system is an electronic system consisting of a Hand Held Receiver and a Transmitter built into the SEMS II Sensor Module on the SCBA backframe. The Transmitter is activated when the PASS is in Full Alarm. When a Transmitter is activated, it sends out a radio signal in all directions that is received by the Hand Held Receiver. Understanding how the radio signal from a Transmitter behaves and how the Hand Held Receiver receives and displays the strength of that signal are critical to understanding the operation of the SCOTT PAK-TRACKER locator system. WARNINGREAD AND UNDERSTAND THIS ENTIRE MAN-UAL AND THE PAK-TRACKER LOCATOR SYSTEM MANUAL, P/N 595102-01. TRAINING IS REQUIRED BEFORE USE OF THIS EQUIPMENT IN A HAZARDOUS SITUATION. THE TRAINING MUST INCLUDE AN UNDERSTANDING OF THE LIMITATIONS OF THE EQUIPMENT AND HOW TO INTERPRET LOCATING INFORMATION, ALONG WITH EXTENSIVE PRACTICE WITH THE SYSTEM IN A VARIETY OF ENVIRONMENTS. USE OF THIS EQUIPMENT MUST BE A PART OF A COMPLETE PERSONNEL ACCOUNTABILITY SYSTEM. ALWAYS UPDATE TRAINING WITH EACH NEW PIECE OF EQUIPMENT. USE OF A PAK-TRACKER LOCATOR SYSTEM WITHOUT PROPER TRAIN-ING MAY PLACE THE USERS AT HIGHER RISK IN DANGEROUS SITUATIONS WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.MULTIPLE SIGNAL PATHS ARE POSSIBLEOPERATION AND USE OF THE SCOTT PAK-TRACKER LOCATOR SYSTEM
Page 19 of 36P/N 595289-01 Rev B  5/15WARNINGCONTINUED TRAINING AND PRACTICE IN A VARIETY OF SITUATIONS IS ESSENTIAL TO DEVELOPING THE SKILLS TO PROPERLY IN-TERPRET THE INFORMATION PROVIDED BY THE PAK-TRACKER LOCATOR SYSTEM. USE OF THIS EQUIPMENT WITHOUT TRAINING AND PRACTICE MAY JEOPARDIZE ALL PERSONNEL INVOLVED WHICH COULD LEAD TO SERIOUS INJURY OR DEATH.Successful operation of the PAK-TRACKER Locator system depends heavily on the interpretation of the relative signal strength information displayed on the Hand Held Receiver along with all other available information about the possible location of the activated transmitter. The Hand Held Receiver is very sensitive in responding to small differences in signal strength. The relative strength of the Transmitter signal detected by the Hand Held Receiver will vary depending on:1.  The distance from the Transmitter to the Hand Held Receiver, 2.  The path the Transmitter signal has taken to get to the Hand Held Receiver,3.  The materials between the Transmitter and the Hand Held Receiver which may have affected the signal from the Transmitter. The user of the Hand Held Receiver must interpret the readings on the Hand Held Receiver display along with other information, such as:–  training and knowledge in systematic search and rescue techniques,–  their sense of sight (watch where you are going),–  their sense of sound (listen for an activated PASS device), –  the deployment of the missing personnel, –  knowledge of the building layout and building materials, Do not rely solely on the readings from the Hand Held Receiver to locate the activated Transmitter. Refer to the PAK-TRACKER Locator System User Instructions, SCOTT P/N 595102-01 for complete details on the use of the PAK-TRACKER Locator System.When a SEMS II Control Console has been programmed with the user’s RFID Tag, the PAK-TRACKER locator system will display the rst eight characters of the Employee ID number as programmed on the RFID Tag. The rst eight (8) characters of the Employee ID number on the RFID Tag must be unique to that individual. Use a badge number or some other identier that is not shared by anyone else. Using a unique number in the rst eight (8) characters will assure that searchers using the PAK-TRACKER locator system will not see two signals with the same number displayed.If the RFID Tag is not used, PAK-TRACKER locator system will display the default eight digit ID number which appears on a label beside the cable connection on the Sensor Module. This default number can be reprogrammed using the SCOTT Pak-Link Computer Interface. Refer to the Pak-Link Computer Interface Installation and Use Instructions, SCOTT P/N 595123-01, for complete details.To return to the default ID number and remove the programmed RFID card number, proceed as follows:1.  Verify that the air cylinder is closed and there is no residual air in the system.2.  Verify that the electronics have been inactive for at lease thirty (30) seconds.3.  Press and hold the YELLOW button on the Console for eight (8) seconds until the red LEDS begin ashing alternately. In addition, the unit will automatically return to the default ID number:–  if the battery cover is opened and/or the batteries are removed,   OR–  after twenty-four hours.SCOTT recommends re-programming with the RFID card in accordance with your orga-nization's procedures to assure that the user's unique ID number is in use at all times.
Page 20 of 36P/N 595289-01 Rev B   5/15REGULAR OPERATIONAL INSPECTION Inspect and test the SCOTT SEMS II distress alarm, SEMS II Accountability System, and the PAK-TRACKER Locator System along with the inspection and test of the SCOTT SCBA respirator before each use. Refer to the PAK-TRACKER User Instruc-tions, SCOTT P/N 595102-01, provided with the SCOTT PAK-TRACKER Hand Held Receiver for complete details. Include the following inspection procedures with the REGULAR OPERATIONAL INSPECTION procedures dened in your respirator in-structions. If any malfunction of the respirator, the PAK-TRACKER Locator System, or the SEMS II distress alarm or Accountability System is noted during the inspection, remove the respirator from service and tag for repair by authorized personnel.To test the PAK-TRACKER locator transmitter, you must have an operating SCOTT PAK-TRACKER Hand Held Receiver.WARNINGFOLLOW REGULAR OPERATIONAL INSPECTION PROCEDURE EXACTLY. IF THE SEMS II DISTRESS ALARM DOES NOT ACTUATE, OR IF ANY OTHER FEATURE DOES NOT OPERATE AS DESCRIBED OR IF ANY OTHER OPERATIONAL MALFUNCTION IS NOTED, DO NOT USE THE RESPIRATOR.CAUTIONTHE PERFORMANCE PROPERTIES OF THE SEMS II DISTRESS ALARM CANNOT BE PROPERLY TESTED IN THE FIELD.WARNINGTHE PROPER OPERATION OF THE LOCATOR SYSTEM CANNOT BE CHECKED WITHOUT CHECKING ALL COMPONENTS OF THE SYSTEM TOGETHER. THE REGULAR OPERATIONAL INSPECTION MUST INCLUDE THE HAND HELD RECEIVER AND THE BASE STATION WORKING WITH EACH OTHER TO CONFIRM PROPER OPERATION. FAILURE TO PROPERLY INSPECT THE COMPLETE SYSTEM MAY RESULT IN FAILURE OF ONE COMPONENT WHICH COULD LEAD TO SERIOUS INJURY OR DEATH.NOTEIN SEVERAL OF THE INSPECTION PROCEDURES DESCRIBED A FULL ALARM WILL BE OBSERVED. THE FULL ALARM CONDITION INCLUDES AN AUDIBLE TONE THAT CAN EXCEED 95 DBA AT 3 METERS (9.9 FT.). TO PREVENT POS-SIBLE HEARING DAMAGE DURING TEST, IMMEDIATELY RESET THE ALARM ON VERIFICATION THAT IT IS FUNCTIONING PROPERLY. WEAR HEARING PROTECTION IF PROLONGED OR REPEATED EXPOSURE TO A FULL ALARM CONDITION IS ANTICIPATED.NOTEIF THIS INSPECTION IS DONE IN DIRECT SUNLIGHT IT MAY BE HELPFUL TO SHADE THE LENS ON THE CONTROL CONSOLE WITH YOUR HAND TO BE SURE THE LIGHTS ARE FLASHING AS DESCRIBED.1.  While performing the visual inspection of the respirator, visually inspect all distress alarm enclosures, lenses, and wire conduits for cracks, wear or other damage. If any damage is found, remove the respirator from service and tag for repair by qualied personnel. 2.  Inspect the SCOTT PAK-TRACKER Hand Held Receiver for any cracks or signs of damage. If any damage is found, remove the unit from service and tag for repair by qualied personnel. 3.  Turn on the SCOTT PAK-TRACKER Hand Held Receiver according to the operat-ing instructions provided with the unit. Position the Hand Held Receiver near by.4.  Turn on the computer with the SCOTT SEMS II MESH GATEWAY Software with the PCMCIA Communications Card or USB Gateway installed, according to this instructions. Position the computer near by.5.  With the cylinder valve closed, press the manual alarm button, located on the front of the distress alarm control console. a)  The manual alarm shall sound a loud almost continuous 3 tone chirp ac-companied by ashing of the red signal light on the control console. b)  The PAK-TRACKER Hand Held Receiver will sound an alarm and display the unique identication number of the SEMS II distress alarm. Use the SCROLL button on the Hand Held Receiver to highlight the active ID number and press the ENTER button on the Hand Held Receiver to select the displayed ID number. Point the unit directly at and in close proximity to the respirator. The signal strength displayed will be at its highest value.c)  Verify that the SEMS II functions are all operating properly and that PASS and EVAC alarms and acknowledgements operate according to these instructions.6.  Reset the manual alarm by pressing twice on the reset button located on the side of the control console (fully depress reset button, release and press again). a)  The unit will sound three chirps and the green light will ash. b)  The PAK-TRACKER Hand Held Receiver will reset to its non-alarm state. 7.  Turn the SEMS II distress alarm OFF by pressing the reset button twice again. The unit will sound a two tone chirp and the green light will go out.8.  Open the cylinder valve to pressurize the respirator system. The distress alarm shall sound 3 quick chirps and the light on the control console shall begin ash-ing green about once a second. The 3 chirps will sound approximately the same time the VIBRALERT in the mask mounted regulator actuates briey. Make sure the air ow is stopped by pressing the air saver/donning switch. WARNINGIN SEVERAL OF THE INSPECTION PROCEDURES DESCRIBED A FULL ALARM WILL BE OBSERVED. THE FULL ALARM CONDITION INCLUDES AN AUDIBLE TONE THAT CAN EXCEED 95 DBA AT 3 METERS (9.9 FT.). TO PREVENT POSSIBLE HEARING DAMAGE DURING TEST, IMMEDIATELY RESET THE ALARM ON VERIFICATION THAT IT IS FUNCTIONING PROPERLY. WEAR HEARING PROTECTION IF PROLONGED OR REPEATED EXPOSURE TO A FULL ALARM CONDITION IS ANTICIPATED.
Page 21 of 36P/N 595289-01 Rev B  5/159.  To check the pre-alarm, leave respirator motionless for twenty (20) seconds. The green ashing light shall be replaced by a red ashing light. An ascending/descending tone will sound increasing in volume. Leave the respirator motionless.10.  After the pre-alarm condition occurs, check the pre-alarm reset. Within twelve (12) seconds of the pre-alarm, move the respirator to activate the motion sensor. The SEMS II distress alarm shall reset to sensing mode. The red ashing light shall be replaced by a green ashing light and the ascending/descending tone shall stop.  Continue with regular operational inspection of respirator as directed by respirator instructions or your approved respiratory protection plan procedure. During the inspection the respirator must be moved or turned every thirty (30) seconds or less to prevent the sounding of the full alarm. After completion of all respirator checks and before turning off the cylinder valve:1.  Check the manual reset of the pre-alarm. Leave the respirator motionless until pre-alarm condition occurs. Within twelve (12) seconds press and single click the reset button. Three (3) chirps shall sound, then release button. The distress alarm shall reset to sensing mode and the alternating ashing red lights will be replaced by a ashing green light.2.  To check the full alarm, leave the respirator motionless until the pre-alarm condi-tion occurs. Do not reset. a)  The full alarm shall sound a loud almost continuous tone accompanied by simultaneous ashing of the red signal lights on the control console. b)  The PAK-TRACKER Hand Held Receiver will sound an alarm and display the Identication Number of the SEMS II distress alarm. The displayed number will be either the Sensor ID number which appears on the label on the Sensor Module or the ID number programmed using the SEMS II RFID Tag. Use the SCROLL button on the Hand Held Receiver to highlight the active ID number and press the ENTER button on the Hand Held Receiver to select the displayed ID number. Point the unit directly at and in close proximity to the respirator. The signal strength displayed will be at its highest value.4.  Reset the full alarm by pressing twice on the reset button located on the side of the control console (fully depress reset button, release and press again). a)  The loud alarm shall stop. The unit will sound three chirps and the green light will ash. The unit shall reset to sensing mode. b)  The PAK-TRACKER Hand Held Receiver will reset to its non-alarm state. 5.  Finish all respirator checks involving air ow and turn off the cylinder valve. Use the purge valve to release all residual air pressure in the system.With the cylinder valve OFF:1.  Check the continuing operation of the distress alarm. The distress alarm shall remain active with green light ashing. Do not move respirator, pre-alarm shall occur with twenty (20) seconds. Move respirator slightly, pre-alarm shall reset, green light shall start ashing again.2.  To turn the distress alarm off, press the reset button twice (press, release and press again). If there is air pressure left in the system, the green ashing light will continue to ash while a fteen second beep sequence is heard from the sen-sor module as the residual air bleeds from the system. As soon as the air has completely bled from system, the unit will sound a quick two tone chirp and the PASS DEVICE distress alarm will be inactive. If there is no pressure in the system when the RESET button is pressed twice, there will be no beep sequence. The distress alarm is now in the “OFF” condition. If there is air pressure in the system, the PASS DEVICE distress alarm will return to the active mode.NOTEIF THE LOW BATTERY INDICATION (ONE STEADY CHIRP EVERY TWO (2) SEC-ONDS WITH NO FLASHING LIGHTS) OCCURS AT ANY TIME DURING REGULAR OPERATIONAL INSPECTION, DO NOT USE THE RESPIRATOR. CHANGE THE BAT-TERIES IN THE SENSOR MODULE IMMEDIATELY AND REPEAT THE REGULAR OPERATIONAL TEST OR TAKE THE RESPIRATOR OUT OF SERVICE UNTIL THE BATTERIES ARE CHANGED AND THE REGULAR OPERATIONAL TEST IS SUC-CESSFULLY PERFORMED.FORMED.If any operational problems are found during the REGULAR OPERATIONAL INSPEC-TION, do no use the respirator. Remove the respirator from service and tag for repair by authorized personnel.WARNINGFOLLOW REGULAR OPERATIONAL INSPECTION PROCEDURE EXACTLY. IF THE SEMS II DISTRESS ALARM DOES NOT ACTUATE, OR IF ANY OTHER FEATURE DOES NOT OPERATE AS DESCRIBED OR IF ANY OTHER OPERATIONAL MALFUNCTION IS NOTED, DO NOT USE THE RESPIRATOR.WARNINGIF THE LOW BATTERY INDICATION (ONE STEADY CHIRP EVERY TWO (2) SECONDS WITH NO FLASHING LIGHTS) OCCURS AT ANY TIME DURING REGULAR OPERATIONAL INSPECTION, DO NOT USE THE RESPIRATOR. CHANGE THE BATTERIES IN THE SENSOR MODULE IMMEDIATELY AND REPEAT THE REGULAR OPERATIONAL TEST OR TAKE THE RESPIRATOR OUT OF SERVICE UNTIL THE BATTERIES ARE CHANGED AND THE REGULAR OPERATIONAL TEST IS SUCCESSFULLY PERFORMED.WARNINGFOLLOW REGULAR OPERATIONAL INSPECTION PROCEDURE EXACTLY. IF THE SEMS II DISTRESS ALARM DOES NOT ACTUATE, OR IF ANY OTHER FEATURE DOES NOT OPERATE AS DESCRIBED OR IF ANY OTHER OPERATIONAL MALFUNCTION IS NOTED, DO NOT USE THE RESPIRATOR.
Page 22 of 36P/N 595289-01 Rev B   5/15When performing the REGULAR OPERATIONAL INSPECTION verify that the Sensor Module lights are operating as described below:OPERATION OF SENSOR MODULE LIGHTSNOTETHE ORANGE LIGHT IS A COMBINATION OF THE RED, GREEN, AND BLUE LIGHTS THAT APPEARS ORANGE FROM A DISTANCE. AT CLOSE RANGE THE INDIVIDUAL LIGHTS MAY BE VISIBLE.            ACTION...  SENSOR MODULE LIGHTS WILL…Start up PASS (Open Cylinder) .................................................. Bright Light then Flash GREENNormal Operation ........................................................................ Flash GREENRespirator Low air (1/3 cylinder) ................................................. Flash ORANGE (alternately)Low Battery while ON ................................................................. GREEN light stops ashingShut down  .................................................................................. Lights OFFPress RESET w/unit OFF (BATTERY TEST)  ........................... Bright Light then:   Flash GREEN if Good/Flash RED if LowPress MANUAL ALARM with unit OFF  ..................................... Flash GREEN then Full Alarm Flash REDPress RESET from manual alarm  ............................................. Returns to Flash GREENPASS Pre-Alarm  ........................................................................ Flash RED (alternately)PASS Full alarm ......................................................................... Flash RED (simultaneously)REGULAR OPERATIONAL INSPECTION CONTINUED...
Page 23 of 36P/N 595289-01 Rev B  5/15CLEANING, MAINTENANCE AND STORAGE Cleaning, maintenance and storage of a respirator with a SEMS II distress alarm shall be done as part of the normal respirator CLEANING AND STORAGE and REGULAR OPERATIONAL INSPECTION as described in the OPERATING AND MAINTENANCE INSTRUCTIONS supplied with each SCOTT respirator. Refer to the PAK-TRACKER User Instructions, SCOTT P/N 595102-01, provided with the SCOTT PAK-TRACKER Hand Held Receiver for complete details of cleaning and storage of the Hand Held Receiver.Store the respirator and attached distress alarm in accordance with the OPERATION AND MAINTENANCE INSTRUCTIONS provided with the respirator. Do not store respirators equipped with distress alarms in the proximity of radio antennas or radio transmitter base units. Respirators equipped with SEMS II distress alarms must be stored or transported at least two (2) feet away from radio antennas on re equipment. Refer to the DETECTING AND AVOIDING RADIO FREQUENCY INTERFERENCE section of this instruction for details.Clean the exterior of the SEMS II distress alarm while cleaning the exterior of the respirator by wiping with a damp sponge and thoroughly wiping dry. The Signal Light lens on the front of the control console should be cleaned after every use to insure maximum light intensity at all times. Do not use solvents for cleaning or attempt to paint or apply decals to the exterior surfaces of the SEMS II distress alarm.If during use, the respirator and/or SEMS II distress alarm is suspected of being contaminated by a hazardous substance, the contaminant must be identied and properly removed or the contaminated component(s) must be replaced before next use. Dispose of the contaminant or the contaminated component(s) in accordance with applicable regulatory requirements.Except for the replacement of batteries, no attempt shall be made to do maintenance or to make adjustments or repairs beyond the scope of this instruction manual without proper training. MARKING AND PAINTINGDo not mark, etch, paint, drill, or apply labels to any of the SEMS II ACCOUNTABILITY SYSTEM components or housings in any way.REPLACEMENT PARTS AND SERVICE The SEMS II distress alarm is covered by a one year warranty.Consult your Authorized SCOTT Representative, Distributor or Service Center as to the availability of Service and Parts for the SEMS II distress alarm. Replacement Bat-teries of the type designated are commercially available over the counter, from your SCOTT Distributor, and from most Industrial Battery Distributors.Except for the replacement of batteries, no attempt shall be made to do maintenance or to make adjustments or repairs beyond the scope of this instruction manual without proper training. RETIREMENT CRITERIA AND CONSIDERATIONRetirement criteria and consideration shall be determined by SCOTT trained and Certied Overhaul Technicians.CLEANING, MAINTENANCE AND STORAGE CONTINUED ON NEXT PAGE...
Page 24 of 36P/N 595289-01 Rev B   5/15WARNINGREAD AND UNDERSTAND THE COMPLETE INSTRUCTION MANUAL BEFORE USING A RESPIRATOR WITH A SEMS II DISTRESS ALARM INSTALLED.WHEN THE SEMS II DISTRESS ALARM IS: IT INDICATES THAT:Quiet. No lights or soundFlashing the green lightFlashing the red light and sounding an ascending/descending tone.Flashing the red light and sounding a loud continuous toneChirping once every two (2) seconds with nolightashingThe SEMS II distress alarm is off or the batteries are used up or removed.The SEMS II distress alarm is on, in sens-ing mode, and monitoring your motion.You have not moved in the last twenty (20) seconds, SEMS II distress alarm will go into full alarm in twelve (12) seconds or less if you do not move.Full alarm: You have not moved in the last thirty (30) seconds or more or you pushed the manual alarm button.The batteries are low. You must put in new batteries before using the SEMS II distress alarm again (it will work in low battery conditionlongenoughtoletyounishthecylinder of air you are on).QUICK REFERENCE GUIDE TO USE:WHEN YOU WANT TO: YOU DO: THE SEMS II DISTRESS ALARM DOES:Turn it on.Re-set pre-alarmRe-set full alarmTurnitoff(nishedwithuse)Turn on the manual alarm.Open cylinder valve (cylinder must have air in it).Move so that the respirator moves.3 quick audible chirps, green ashinglightoncontrolconsole.Redashinglightchangestogreen, ascending/descending tone stops.Loud 3 tone chirp stops, 3 quick chirps,thenredashinglightchangestogreenashinglight.Theashinglightgoesoutandafteen(15)secondbeepse-quence occurs as the residual air bleeds off. Unit will sound a two tone chirp at turn off.Goes into full alarm, loud 3 tone chirps from sensor module and bright red ashinglightfromcon-trol console.Press re-set button on control console twice (push, release, push again).Close respirator cylinder valve, open regulator purge valve letting out all the trapped air, close regulator purge valve, press re-set button twice.Press alarm button on control console (works whether the SEMS II distress alarm is on or off).CLEANING, MAINTENANCE AND STORAGE CONTINUED...
Page 25 of 36P/N 595289-01 Rev B  5/15CAUTIONRESPIRATOR SYSTEM MUST NOT BE PRESSURIZED WHEN BATTERIES ARE BEING INSTALLED. DAMAGE TO THE ELECTRONIC COMPONENTS MAY RESULT IF BATTERIES ARE INSTALLED WITH SYSTEM PRESSURIZED.SCOTT respirators equipped with the PAK-ALERT distress alarm require six (6) “AA” cell batteries for operation. The six (6) batteries power the Heads-Up Display, the PASS device, and the PAK-TRACKER Transmitter. NOTETHE UNIT WILL RETURN TO THE DEFAULT ID NUMBER IF THE BATTERY COVER IS OPENED AND/OR THE BATTERIES ARE REMOVED. SCOTT RECOMMENDS RE-PROGRAMMING WITH THE RFID CARD IN ACCORDANCE WITH YOUR ORGANIZATION'S PROCEDURES TO ASSURE THAT THE USER'S UNIQUE ID NUMBER IS IN USE AT ALL TIMES.The batteries should be replaced only by a trained maintenance technician in a clean area known to be nonammable. Replace batteries as follows:1.  Close respirator cylinder valve, open regulator purge valve letting out all the trapped air, close regulator purge valve, press the reset button twice. If there is air pressure left in the system, the green ashing light will continue to ash while a fteen second beep sequence is heard from the Sensor Module as the residual air bleeds from the system. As soon as the air has completely bled from system, the unit will sound a quick two tone chirp and the PASS DEVICE distress alarm will be inactive. If there is no pressure in the system when the RESET button is pressed twice, there will be no beep sequence. If there is air pressure in the system, the PASS DEVICE distress alarm will return to the active mode.NOTEALWAYS BE SURE THAT CYLINDER VALVE IS OFF AND THE PASS DEVICE IS COMPLETELY INACTIVE BEFORE CHANGING BATTERIES. NEVER REMOVE OR REPLACE BATTERIES WITH SYSTEM PRESSURIZED.2.  When replacing batteries on respirators, remove the cylinder and place the res-pirator in a clean, non-hazardous area.3.  Use a Phillips driver to remove the Battery Housing Cover. Carefully remove the cover and set aside.4.  Remove used batteries from battery compartment by sliding them out of the bat-tery compartment.5.  Install six (6) fresh new “AA” batteries of the same type. Always replace all bat-teries at the same time.   The battery holder is marked with the style and orientation of the batteries required.   Use six (6) each of one of the following 1.5 volt AA batteries: – Duracell2 Alkaline MN1500–  Duracell Alkaline MX1500 –  Duracell Alkaline PC1500 –  Duracell Quantum MV1500–  Eveready Energizer3 Alkaline EN91–  Eveready Energizer Alkaline E91.   Do not mix batteries. Verify correct orientation of batteries as shown on label inside the battery holder.WARNINGTHE SEMS II DISTRESS ALARM IS INTENDED TO ASSIST IN LOCATING A PERSON WHO MAY BE IN A LIFE THREATENING SITUATION. FAILURE TO FOLLOW THE INSTRUCTIONS FOR OPENING, CHANGING THE BATTERIES AND RE-CLOSING THE BATTERY COMPARTMENT MAY RESULT IN DAMAGE WHICH COULD CAUSE FAILURE OF THE PASS DURING A LIFE THREATENING EMERGENCY OR COULD CAUSE A FIRE OR EXPLOSION IN A FLAMMABLE OR EXPLOSIVE ATMOSPHERE POSSIBLY RESULTING IN INJURY OR DEATH. WARNINGBATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NONFLAMMABLE.CHANGING THE BATTERIES IN A FLAMMABLE ATMOSPHERE MAY CAUSE AN IGNITION WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.BATTERY REPLACEMENT2 Duracell is a registered trademark of The Procter & Gamble Company, Cincinnati, OH 3 Energizer is a registered trademark of Eveready Battery Company, Inc., St Louis, MO.WARNINGTO REDUCE THE RISK OF EXPLOSION USE BATTERIES ONLY FROM THE LIST PROVIDED, DO NOT MIX OLD BATTERIES WITH UNUSED BATTERIES, AND DO NOT MIX BATTERIES FROM DIFFERENT MANUFAC-TURERS. UNAUTHORIZED SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY AND CAUSE AN EXPLOSION WHICH COULD LEAD TO SERIOUS INJURY OR DEATH. USE SCREWDRIVERTO LOOSEN SCREW AND REMOVE COVERWARNINGALWAYS INSTALL THE BATTERIES IN THE ORIENTATION SHOWN ON THE LABEL. FAILURE TO PROPERLY INSTALL THE BATTERIES WILL RESULT IN EITHER REDUCED OR NO OPERATION OF THE EQUIPMENT WHICH COULD LEAD TO FAILURE OF THE EQUIPMENT AND SERIOUS INJURY OR DEATH OF THE RESPIRATOR USER.BATTERY REPLACEMENT CONTINUED ON NEXT PAGE...
Page 26 of 36P/N 595289-01 Rev B   5/15CHECK YOUR WORK!BEFORE ASSEMBLY OF BATTERY COVER, CHECK TO SEE ALL BATTERIES ARE FRESH, NEW BATTERIES OF THE TYPE INDICATED ABOVE AND THAT THEY HAVE BEEN INSTALLED PROPERLY.BE SURE SEALING SURFACES ARE CLEAN BEFORE REASSEMBLY6.  The battery cover must be installed so that it is water tight after replacement. Clean the sealing rib around battery compartment and sealing face of the cover by wiping with a clean damp cloth to remove any dirt or foreign matter which might prevent a proper seal. Check cover gasket for tears or cuts. If damage is found, remove respirator from service and tag for repair by authorized personnel. 7.  To install battery cover, align the three grooves on the cover with the three tabs on the battery compartment and tighten the cover screw.8.  To test the batteries, verify that the PAK-ALERT distress alarm is in the off condi-tion (cylinder valve closed with no ashing green LED on the control console). a)  Press and hold the reset button on the console. A GREEN light on the console indicates sufcient battery power and that the batteries are properly installed.b)  If the unit displays the LOW BATTERY condition or no light at all, verify that the batteries are properly installed. If the batteries were properly installed, remove the batteries and replace with a new set of six (6) batteries. c)  If another set of properly installed batteries will still not produce a GREEN light on the battery test, remove the unit from service and mark for repair by authorized personnel.AFTER REPLACEMENT OF BATTERIES, PERFORM A REGULAR OPERATIONAL INSPECTION BEFORE RETURNING RESPIRATOR TO SERVICE.BATTERY REPLACEMENT CONTINUED...CAUTIONIMPROPER BATTERY COVER INSTALLATION CAN CAUSE BATTERIES TO OVERHEAT AND MAY CAUSE DAMAGE TO THE PRODUCT. ALWAYS MAKE SURE THAT THE ALIGNMENT GROOVES ON THE BATTERY COVER ARE ALIGNED WITH THE TABS ON THE BATTERY COMPARTMENT DURING INSTALLATION OF THE COVER.
Page 27 of 36P/N 595289-01 Rev B  5/15WARNINGKEEP THE ANTENNAS OF HAND-HELD RADIOS AT LEAST SIX (6) INCHES AWAY FROM THE CONTROL CONSOLE AND THE SENSOR MODULE OF THE SEMS II DISTRESS ALARM WHEN TRANSMITTING. CLOSE PROXIMITY OF RADIO EQUIPMENT TO THE SEMS II DISTRESS ALARM DURING RADIO TRANSMISSION MAY CAUSE THE UNIT TO MALFUNCTION. FAILURE TO RECOGNIZE A MALFUNCTION OF THE SEMS II DISTRESS ALARM AND TAKE THE PROPER CORRECTIVE ACTION MAY RESULT A NONWORKING DISTRESS ALARM WHICH WILL NOT SOUND IF THE USER STOPS MOVING AND LEAD TO SERIOUS INJURY OR DEATH. WARNINGBE AWARE OF THE POTENTIAL EFFECT OF RADIO TRANSMISSIONS FROM BASE STATION OR TRUCK MOUNT RADIOS WHEN USING A RESPIRATOR WITH THE SEMS II DISTRESS ALARM. CLOSE PROXIMITY OF RADIO EQUIPMENT TO THE SEMS II DISTRESS ALARM DURING RADIO TRANSMISSION MAY CAUSE THE UNIT TO MALFUNCTION. FAILURE TO RECOGNIZE A MALFUNCTION OF THE SEMS II DISTRESS ALARM AND TAKE THE PROPER CORRECTIVE ACTION MAY RESULT A NONWORKING DISTRESS ALARM WHICH WILL NOT SOUND IF THE USER STOPS MOVING AND LEAD TO SERIOUS INJURY OR DEATH. DETECTING AND AVOIDING RADIO FREQUENCY INTERFERENCEWhen any electronic device is adversely affected by radio waves, Radio Frequency Interference (RFI) is said to have occurred. All electronic devices like the SEMS II distress alarm may be subject to the effects of RFI. Radio transmissions from the antennas of radios including those used by re ghters, police and other public safety related personnel may produce RFI in the SEMS II distress alarm. RFI may occur while the radio is transmitting if the respirator equipped with the SEMS II distress alarm is in close proximity to a base station or high-powered vehicle mounted radio, or if the antenna of a personal portable hand held radio is touching or within six (6) inches of the Control Console or Sensor Module of the SEMS II distress alarm.Be aware of the symptoms of RFI. A SEMS II distress alarm affected by RFI may temporarily give false indications such as the sudden sounding of the loud continuous three-tone chirp of the full alarm. In some instances the lights on the control console may ash without sounding the alarm. In rare circumstances, an alarm which was sounding may stop.If the SEMS II distress alarm  exhibits any of the symptoms of RFI, identify the source of the RFI and do the following:–  If the symptoms of RFI occur when standing near a base station transmitting antenna or a truck mounted radio antenna, move away from the antenna until the symptoms stop. –  If the symptoms of RFI occur while transmitting on a hand-held radio, move the radio away from the SEMS II distress alarm   . CHECK THE CONTROL CONSOLE AND BE CERTAIN THE GREEN LIGHT IS FLASHING NORMALLY WHEN THE INTERFERENCE STOPS, REGARDLESS OF THE SOURCE.In normal usage with the air cylinder open, the SEMS II distress alarm will typically resume normal operation after experiencing RFI. If the SEMS II distress alarm is affected by RFI when the respirator air supply is turned off or the cylinder is empty, the distress alarm could be turned off during use. If this occurs, depress the RED Manual Alarm Button to activate the alarm. IF THE SYMPTOMS OF RFI OCCUR, THE RESPIRATOR USER MUST CHECK THE SEMS II DISTRESS ALARM TO VERIFY THAT IT IS FUNCTIONING PROPERLY. IF THE GREEN LIGHT ON THE CONTROL CONSOLE DOES NOT RESUME FLASH-ING IN THE NORMAL MANNER AFTER EXPERIENCING THE SYMPTOMS OF RFI, OR IF THE UNIT CONTINUES TO MALFUNCTION IN ANY OTHER WAY, PROCEED TO A SAFE AREA, REMOVE THE RESPIRATOR FROM SERVICE AND TAG FOR REPAIR BY AUTHORIZED PERSONNEL.HAND HELD RECEIVERSENSOR MODULECONTROL CONSOLEKEEP RADIO ANTENNAS AT LEASTSIX (6) INCHES FROM THESE AREASRFI WARNING AREAS
Page 28 of 36P/N 595289-01 Rev B   5/15Minimize or eliminate the effects of RFI by protecting the SEMS II distress alarm  with the following steps:– Maintain a safe distance from a base station transmitting antenna or a truck mounted radio antenna.– Keep the antennas of hand held radios at least six (6) inches away from the CON-TROL CONSOLE or the SENSOR MODULE. RFI AND THE PAK-TRACKER HAND HELD RECEIVERIf the Hand Held Receiver experiences RFI, it may be necessary to remove the Hand Held Receiver from service. In a known safe, non-hazardous area, remove and reinstall the batteries to reset the unit (see the BATTERY REPLACEMENT section of the PAK-TRACKER Locator System User Instructions, SCOTT P/N 595102-01). Then inspect and return the Hand Held Receiver to service.
Page 29 of 36P/N 595289-01 Rev B  5/15CLASS B DIGITAL DEVICENote: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:–  Reorient or relocate the receiving antenna–  Increase the separation between the equipment and receiver.–  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.–  Consult the dealer or an experienced radio/TV technician for help.FCC COMPLIANCE FCC Compliance Statement (Part 15.19)This device complies with Part 15 of the FCC Rules. Operation is subject to the  following two conditions: 1.  This device may not cause harmful interference, and 2.  This device must accept any interference received, Including interference that may cause undesired operation.   FCC Warning (Part 15.21)Changes or modications not expressly approved by the party responsible for compli-ance could void the user’s authority to operate the equipment.This portable transmitter with its antenna complies with FCC/IC RF exposure limits for general population / uncontrolled exposure. The X3 SEMS II Control Console Transmitter has been assigned  FCC ID:T5E201122 /  The X3 SEMS II with BLUETOOTH Control Console Trans-mitter has been assigned FCC ID: T5E201122ASAFETY LISTINGSCAUTIONDO NOT USE A FIBERGLASS WRAPPED ONE HOUR CYLINDER ON A MODEL 4.5 AIR-PAK EQUIPPED WITH A PAK-ALERT DIS-TRESS ALARM AS THE WEIGHT WILL EXCEED THE 35 LBS APPROVAL LIMIT FOR SCBA’S ESTABLISHED BY NIOSH.INDUSTRY CANADA COMPLIANCE   Industry Canada StatementThe term “IC” before the certication / registration number only signies that the In-dustry Canada technical specications were met.   Section 14 of RSS-210The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF eld in excess of Health Canada limits for the general population. Consult Safety Code 6, obtainable from Health Canada’s web site: www.hc-sc.gc.ca/rpb.This Device complies with Industry Canada License-exempt RSS standard(s). Opera-tion is subject to the following two conditions: 1.  this device may not cause interference, and 2.  this device must accept any interference, including interference that may cause undesired operation of the device.IC ID:  6453A-201122 / 6453A-201122ALA DÉCLARATION DE CANADA D'INDUSTRIEL' « IC » de terme avant que la certication/le nombre d'enregistrement signie seule-ment que le Canada d'Industrie spécications techniques ont été rencontrées.   Sectionner 14 de RSS-210 Le programme d'installation de cet équipement de radio doit garantir que l'antenne est localisée ou tel est indiqué qu'il n'émet pas le champ de RF dépassant les limites de Canada de Santé pour la population générale. Consulter le Code de Sécurité 6, procurable du site Web de Canada de Santé : www.hc-sc.gc.ca/rpb. Cet appareil est conforme aux normes Industry Canada exemptes de licence RSS standard(s). L'opération est assujetti au suivre deux conditions :1)  cet appareil ne peut pas causer l'intervention, et 2)  cet appareil doit accepter de l'intervention, y compris l'intervention qui peut causer l'opération non désirée de l'appareil.IC ID: 6453A-201122 / 6453A-201122A
Page 30 of 36P/N 595289-01 Rev B   5/15INTRINSICALLY SAFE LISTINGThe SEMS II distress alarm with Integrated Locator transmitter, Model Number 200451-SERIES, when installed on a SCOTT respirator, is listed as intrinsically safe per ANSI/UL Std. UL-913 in Class I, II,  Division 1,  Groups C, D, E, F, and G hazardous locations by SGS U. S. TESTING COMPANY, Inc. Only when powered by the batteries listed in this instruction or indicated on the label on the sensor module.To maintain Intrinsic Safety Listing, inspect the respirator with SEMS II distress alarm regularly per the Regular Operational Inspection procedures in this instruction. Sub-stitution of Components May Impair Intrinsic Safety. To reduce the risk of ignition of a ammable atmosphere, batteries must only be changed in an area known to be nonammable. To reduce the risk of explosion, use only the approved batteries, do not mix old batteries with unused batteries, or mix batteries from different manufacturers.HAND HELD RECEIVER NON-INCENDIVE LISTINGThe SCOTT PAK-TRACKER LOCATOR SYSTEM Hand Held Receiver P/N 200397-02 is listed by SGS U. S. TESTING COMPANY, Inc. as Non-Incendive per ANSI/UL Std. UL-1604 for use in Class I Division 2 Groups A, B, C, and D hazardous locations. Temperature Code T4 (-25° C to 85° C). To maintain the Non-Incendive Listing, the equipment must be inspected regularly per the following Regular Operational Inspec-tion procedures. Do not tamper with or substitute components in any manner. Use only SCOTT Battery Pack P/N 200402-02. Open the battery compartment only in an area known to be free of ammable or explosive hazards.WARNING – Substitution of Components May Impair the Non-Incendive Listing. To reduce the risk of ignition of a ammable atmosphere, battery must only be changed in an area known to be nonammable. Do not substitute any other battery or power source.WARNINGIF THE SEMS II DISTRESS ALARM IS USED IN AN AREA OF EXPLOSIVE OR FLAMMABLE HAZARDS, FAILURE TO REGULARLY INSPECT AS INSTRUCTED, FAILURE TO CORRECT DAMAGE BEFORE USE, OR THE INSTALLATION OF INCORRECT BATTERIES MAY LEAD TO A FIRE OR EXPLOSION WHICH MAY RESULT IN PERSONAL INJURY OR DEATH. WARNINGFAILURE TO REGULARLY INSPECT THE HAND HELD RECEIVER AS DESCRIBED IN THIS IN-STRUCTION OR FAILURE TO CORRECT ANY DAMAGE FOUND, MAY IMPAIR THE SAFETY OF THE EQUIPMENT. THE INSTALLATION OF INCORRECT BATTERY OR SUBSTITUTION OF ANY OTHER COMPONENTS MAY IMPAIR THE SAFETY OF THE EQUIPMENT. IF THE EQUIPMENT IS USED IN AN EXPLOSIVE OR FLAMMABLE ATMOSPHERE, IMPAIRING THE SAFETY OF THE UNIT MAY LEAD TO A FIRE OR AN EXPLOSION WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.WARNINGREPLACE HAND HELD RECEIVER BATTERY PACK ONLY WITH SCOTT BATTERY PACK, PART NO. 200402-02. DO NOT REMOVE, RE-CHARGE, OR REPLACE BATTERY PACK WHILE THE DEVICE IS IN A HAZARDOUS LOCATION. REMOVING, RE-CHARGING, OR REPLACING THE BATTERY PACK WHILE THE DEVICE IS IN A HAZARDOUS LOCATION MAY LEAD TO A FIRE OR AN EXPLOSION WHICH COULD RESULT IN SERIOUS INJURY OR DEATH.WARNINGRADIO FREQUENCY INTERFERENCE (RFI) MAY CAUSE A MALFUNCTION OF THE SEMS II PERSONAL DISTRESS ALARM. USERS OF RESPIRATORS EQUIPPED WITH THE SEMS II PERSONAL DISTRESS ALARM MUST BE AWARE OF THE PROPER OPERATION OF THE DISTRESS ALARM. FAILURE TO RECOGNIZE A MALFUNCTION OF THE EQUIPMENT AND TAKE PROPER CORRECTIVE ACTION MAY RESULT FAILURE OF THE SEMS II PERSONAL DISTRESS ALARM AND LEAD TO SERIOUS IN-JURY OR DEATH.RADIO FREQUENCY INTERFERENCE (RFI)When any electronic device is adversely affected by radio waves, Radio Frequency Interference (RFI) is said to have occurred. All electronic devices like the SEMS II distress alarm may be subject to the effects of RFI, most of which are temporary in nature. Users of the SCOTT SCBA with the integrated SEMS II distress alarm must be familiar with the normal operation of the distress alarm and must also be familiar with how to identify and avoid the effects of RFI (see DETECTING AND AVOIDING RADIO FREQUENCY INTERFERENCE on page 6). If RFI occurs to the SEMS II distress alarm, it may be caused by transmissions from hand-held or personal radios where the radio antenna is touching or very close to (less than 6 inches from) com-ponents of the SEMS II distress alarm. It may also be caused by transmissions from base stations or high-powered vehicle mounted radios or any other powerful source of electromagnetic radiation. WARNINGSUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY. TO REDUCE THE RISK OF IGNITION OF A FLAMMABLE ATMOSPHERE, BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NONFLAMMABLE. TO REDUCE THE RISK OF EXPLOSION, DO NOT MIX OLD BATTERIES WITH UNUSED BATTER-IES, OR MIX BATTERIES FROM DIFFERENT MANUFACTURERS.
Page 31 of 36P/N 595289-01 Rev B  5/15SEMS II DISTRESS ALARMPERFORMANCE SPECIFICATIONSSound Levels: Pre-Alarm... ......................... 80 to 105 dBA incrementally at left ear Full-Alarm ............................ 95 to 100 dBA @ 9.9 Ft. (3m)  Frequency Range ............... 1.5 KHz to 4 KHzBattery Life (fresh batteries)Alkaline Batteries:  Automatic (green ashing light, no sound) ..............Approx. 20 hours Full Alarm (red ashing light, 95 dBA sound)....... .Approx. 8 hoursComplianceThe SCOTT SEMS II distress alarm is a NIOSH approved accessory for use on only the following SCOTT SCBA respirators: (NIOSH approval numbers have been included for identication):SCOTT AIR-PAK X3 SNAP-CHANGE SCBASCOTT 2.2 AIR-PAK X3 (30 min.)  TC-13F-0712CBRNSCOTT 4.5 AIR-PAK X3 (30 min.)  TC-13F-0714CBRNSCOTT 4.5 AIR-PAK X3 (45 min.)  TC-13F-0716CBRNSCOTT 4.5 AIR-PAK X3 (60 min.)  TC-13F-0718CBRNSCOTT 5.5 AIR-PAK (30 min.)  TC-13F-0720CBRNSCOTT 5.5 AIR-PAK (45 min.)  TC-13F-0722CBRNSCOTT 5.5 AIR-PAK (60 min.)  TC-13F-0724CBRNSCOTT 5.5 AIR-PAK (75 min.)  TC-13F-0726CBRNPERSONAL COMPUTERThe personal computer Base Station environmental operating parameters are totally dependant on the limitations of the personal computer used with the SCOTT SEMS II Accountability System. Do not use the personal computer Base Station in environ-ments for which it is not designed. Handle the personal computer according to the instructions provided with the personal computer.EXPORT AND IMPORTThe international transport of the SCOTT SEMS II Accountability System and portions thereof is regulated under United States export regulations and may be regulated by the import regulations of other countries.If you have any questions or concerns regarding these regulations, contact SCOTT at 1-800-247-7257 (or 704-291-8300 outside the continental United States).SCOTT AIR-PAK X3 CGA SCBASCOTT 2.2 AIR-PAK X3 (30 min.)  TC-13F-0711CBRNSCOTT 4.5 AIR-PAK X3 (30 min.)  TC-13F-0713CBRNSCOTT 4.5 AIR-PAK X3 (45 min.)  TC-13F-0715CBRNSCOTT 4.5 AIR-PAK X3 (60 min.)  TC-13F-0717CBRNSCOTT 5.5 AIR-PAK (30 min.)  TC-13F-0719CBRNSCOTT 5.5 AIR-PAK (45 min.)  TC-13F-0721CBRNSCOTT 5.5 AIR-PAK (60 min.)  TC-13F-0723CBRNSCOTT 5.5 AIR-PAK (75 min.)  TC-13F-0725CBRNNOTEDO NOT USE A FIBERGLASS WRAPPED ONE HOUR CYLINDER ON A MODEL 4.5 AIR PAK EQUIPPED WITH A SEMS II DISTRESS ALARM AS THE WEIGHT WILL EXCEED THE 35 LBS APPROVAL LIMIT FOR SCBA’s ESTABLISHED BY NIOSH.
Page 32 of 36P/N 595289-01 Rev B   5/15END USER LICENSE AGREEMENTIMPORTANT-READ CAREFULLY: THIS IS A LEGAL AGREEMENT BETWEEN YOU, A SINGLE ENTITY (AS DEFINED IN SECTION 11 BELOW) (“YOU[R]”) AND SCOTT TECHNOLOGIES, INC. d/b/a SCOTT HEALTH AND SAFETY, 4320 GOLDMINE ROAD, MONROE, NC 28110 (“SCOTT”) PERTAINING TO THE SOFTWARE YOU ARE ABOUT TO INSTALL, COPY, ACCESS OR OTHERWISE USE (SINGULARLY AND COLLECTIVELY, THE “SOFTWARE”). SCOTT LICENSES THE SOFTWARE TO YOU ONLY UPON THE EXPRESS CONDITION THAT YOU ACCEPT ALL OF THE TERMS AND CONDITIONS CONTAINED IN THIS LICENSE AGREEMENT (THE “AGREEMENT”). YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE ACCESSING THE SOFTWARE. BY OPENING THE SEALED PACKAGE, INSTALLING, COPYING, ACCESSING OR OTHERWISE USING THE SOFTWARE, YOU ACCEPT THESE TERMS AND CONDITIONS AND UNDERSTAND THAT THEY WILL BE LEGALLY BINDING ON YOU. IF YOU DO NOT AGREE TO THE TERMS, THEN SCOTT IS UNWILLING TO LICENSE THE SOFTWARE TO YOU. IF YOU DO NOT AGREE WITH THEM, OR DO NOT WANT THEM BINDING ON YOU, YOU MUST NOT INSTALL, COPY, ACCESS OR OTHERWISE USE THE SOFTWARE AND YOU MAY RETURN THE SOFTWARE FOR A FULL REFUND (LESS ANY SHIP-PING FEES) WITHIN THIRTY (30) DAYS OF YOUR LICENSE PURCHASE DATE. IMPORTANT WARNING: IT IS CRITICAL FOR YOU TO REGULARLY BACK UP YOUR DATA. DATA BACK UP IS SOLELY YOUR RESPONSIBILITY. IN NO EVENT SHALL SCOTT BE LIABLE FOR ANY LOSS OF DATA.1.  Grant of License. The Software is protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. The Software is licensed, not sold, as follows: SCOTT hereby grants and you accept a non-exclusive, non-transferable license, subject to each provision of this Agree-ment, including, but not limited to, Sections 2 and 3 herein: to install and use the Software on only one (1) computer at one (1) location at any one (1) time. All rights not expressly granted to you are hereby reserved by SCOTT.  Upgrades: If the Software is an upgrade (“New Version”) to a version previ-ously licensed to you (“Previous Version”), you must destroy all copies of the Previous Version. SCOTT reserves the right to require you to show satisfactory proof that the Previous Version was destroyed. If SCOTT provides you additional materials that supplement or extend the Software, those additional materials shall be subject to this Agreement’s terms and conditions unless SCOTT otherwise agrees in writing. Notwithstanding the foregoing, you may retain one (1) back-up copy of the Previous Version and may use it solely: (i) to install the New Version hereby licensed and (ii) for archival (backup) purposes to reinstall the New Ver-sion hereby licensed if the initial installation fails. Under no circumstances may you otherwise operate the Previous Version and your license rights to each such Previous Version are terminated upon your rst successful installation of the New Version.2.  Title and Copyright. It is hereby understood and agreed that as between SCOTT and you, SCOTT is the owner of all rights, title and interest, including the copy-right, to the Software recorded on the media on which the Software is furnished and all subsequent copies thereof, regardless of the media or form in which the Software or copies thereof may exist. Except as expressly provided herein, you do not acquire any rights to the Software through the purchase of licenses to the Software.3.  Limitations On Use. The License granted to You shall not extend to any third party. Except as specically permitted pursuant to this Agreement, You shall not: (i) copy (except as permitted by applicable law or as provided in this Agreement), sell, modify, translate, transfer, reverse engineer, decompile or disassemble the Software, provided, however, that if You require information necessary to create an independent program which is interoperable with the Software, upon written noti-cation of such requirement SCOTT will make the necessary information available to You upon You entering into obligations to keep the information condential and payment of SCOTT’s costs of providing such information; (ii) remove any proprietary notice, label or mark, on or in the Software, whether in machine language or hu-man readable form; (iii) transmit or distribute the Software, in whole or in part; (iv) create any derivative work that is based on or incorporates the Software, in whole
Page 33 of 36P/N 595289-01 Rev B  5/15END USER LICENSE AGREEMENT CONTINUED ON NEXT PAGE...or in part; (v) use the Software to provide any service bureau by which any third party can access the Software, or by which information produced by the Software is sold or given to any third party through use of any technology now known or later devised; (vi) sublicense, assign, delegate or otherwise transfer the License or any right or obligation related to it for any reason without SCOTT’s prior written consent (any attempt to sublicense, assign, delegate or transfer this license, by contract, statute, corporate merger of any sort, regulation or court order without SCOTT’s prior written consent shall be void); (vii) export the Software outside of the country in which it was purchased without SCOTT’s express prior written consent; or (viii) install and operate the Software at any location not specically licensed in writing by SCOTT for such installation whether through physical transfer of a copy, electronic access through a wide area network of any description, or by any other means now known or hereinafter devised. Unauthorized copying of the Software or failure to comply with the above restrictions, will result in automatic termination of this Agreement. Un-authorized copying or distribution of the Software constitutes copyright infringementandmaybepunishableinafederalcriminalactionbyaneofuptoU.S.$250,000andimprisonmentuptove(5)years.Inaddition,federal civil remedies for copyright infringement allow for the recovery of actual damages based on the number of copies produced or statutory damages of up to U.S. $150,000 for willful copyright infringement.4.  Term. This Agreement shall continue for as long as you use the Software licensed herein or until terminated by SCOTT, whichever occurs rst. Without prejudice to any other rights, this Agreement will terminate if you fail to comply with any of its terms or conditions. You agree, upon termination, to destroy all copies of the Software.5.  NO WARRANTIES. THE SOFTWARE IS FURNISHED “AS IS” AND WITH ALL FAULTS. SCOTT, ITS AFFILIATES, RESELLERS, TECHNICAL SUPPORT PROVIDERS, DISTRIBUTORS, LICENSORS, AND SUBLICENSEES, MAKE, AND YOU RECEIVE, NO WARRANTIES, EXPRESS, IMPLIED, STATUTORY, OR IN ANY COMMUNICATION WITH YOU. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, SCOTT, ITS AFFILIATES, RESELLERS, TECHNICAL SUPPORT PROVIDERS, DISTRIBUTORS, LICENSORS, AND SUBLICENSEES DISCLAIM ALL WARRANTIES AND CONDITIONS, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT, OR ANY WARRANTY THAT OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE. YOU EXPRESSLY ASSUME ALL RISK RESULTING FROM SUPPORT SERVICES (WHETHER PERFORMED IN WHOLE, IN PART OR NOT AT ALL), OR FROM ANY VIRUS, DOWNLOADED MATERIAL, HARMFUL COMPONENT, OR THROUGH ANY INTERNET USE RESULTING FROM OR RELATING TO YOUR USE OF THE SOFTWARE OR ANY SITE OR SERVER THROUGH WHICH THE SOFTWARE IS AVAILABLE. YOU SHALL BE SOLELY RESPONSIBLE FOR THE ACCURACY AND TRANSMISSION OF ALL DATA ENTERED, ANY DAMAGE THAT RESULTS FROM OR IS ASSOCIATED WITH USE OF THE SOFTWARE.  IF THE SOFTWARE WAS PURCHASED IN THE UNITED STATES, THE ABOVE EXCLUSIONS MAY NOT APPLY TO YOU SINCE SOME STATES DO NOT AL-LOW THE EXCLUSION OF IMPLIED WARRANTIES. IN ADDITION TO THE ABOVE WARRANTY RIGHTS, YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE. THE ENTIRE RISK ARISING OUT OF USE OR PERFORMANCE OF THE SOFTWARE PRODUCT REMAINS WITH YOU.6.  LIMITATION OF LIABILITY. THE LIMITATION OF LIABILITY IS TO THE MAXI-MUM EXTENT PERMITTED BY APPLICABLE LAW. IN NO EVENT SHALL ANY OR ALL OF THE FOLLOWING: SCOTT, ITS AFFILIATES, RESELLERS, TECHNICAL SUPPORT PROVIDERS, DISTRIBUTORS, LICENSORS AND/OR SUBLICENSEES BE LIABLE FOR ANY DAMAGES, WHETHER ARISING IN CONTRACT, TORT OR OTHERWISE AND INCLUDING, WITHOUT LIMIT, ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OR CORRUP-TION OF BUSINESS INFORMATION OR OTHER DATA, COST OF COVER, OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF OR INABILITY TO USE THE SOFTWARE OR THE FAILURE TO PROVIDE FULL
Page 34 of 36P/N 595289-01 Rev B   5/15OR ADEQUATE SUPPORT SERVICES, EVEN IF SCOTT OR ANY OF ITS AFFILIATES HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAM-AGES. YOU ACKNOWLEDGE THAT THE LICENSE FEE AMOUNT REFLECTS THIS ALLOCATION OF RISK. IN ANY CASE, THE ENTIRE LIABILITY OF SCOTT, ITS AFFILIATES, RESELLERS, DISTRIBUTORS, LICENSORS AND SUBLICENSEES, UNDER ANY PROVISION OF THIS AGREEMENT SHALL BE LIMITED TO THE AMOUNT ACTUALLY PAID BY YOU FOR THE PARTICU-LAR SOFTWARE VERSION BEING LICENSED TO YOU PURSUANT TO THIS AGREEMENT AND SPECIFICALLY EXCLUDES ANY AMOUNT PAID BY YOU FOR SERVICES, HARDWARE, AND/OR ANY OTHER SOFTWARE. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LI-ABILITY, THE ABOVE LIMITATION MAY NOT APPLY TO YOU.7.  JAVA. The Software may contain support for programs written in Java. Java technology is not fault tolerant and is not designed, manufactured, or intended for use or resale as on-line control equipment in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navi-gation or communication systems, air trafc control, direct life support machines, or weapons systems, in which the failure of Java technology could lead directly to death, personal injury, or severe physical or environmental damage.8.  Export Restrictions / Restricted Rights for US Government Customers. You shall not to export or re-export the Software, any part thereof, or any process or service that is the direct product of the Software (collectively referred to as the “Restricted Components”), to any country, person or entity subject to U.S. export restrictions. You specically agree not to export or re-export any of the Restricted Components (i) to any country to which the U.S. has embargoed or restricted the export of goods or services, which currently include, but are not necessarily limited to the Balkans, Belarus, Burma, Cuba, Iran, Iraq, Liberia, Libya, North Korea, Sudan, Syria, and Zimbabwe (the foregoing list is subject to change - see http://www.treas.gov/ofces/enforcement/ofac/programs/),  or  to  any  national  of  any such country, wherever located, who intends to transmit or transport the products back to such country; (ii) to any entity You know or have reason to know will utilize the Restricted Components in the design, development or production of nuclear, chemical or biological weapons; or (iii) to any entity You know or have reason to know has been prohibited from participating in U.S. export transactions by any federal agency of the U.S. government. The Software may be a “commercial item” as that term is dened in 48 C.F.R. 2.101 (October 2004), consisting of “com-mercial computer software” and “commercial computer software documentation” as such terms are used in 48 C.F.R. 12.212 (October 2004) and “commercial computer software,” “computer databases,” “computer programs,” and “computer software documentation” as such terms are dened in DFARS 252.227-7014(a) (June 1995). Consistent with 48 C.F.R. 12.212, 48 C.F.R. 27.405(b) (October 2004), 48 C.F.R. 227.7202-3 (October 2004), and DFARS 227.7202-3 (October 1998), all U.S. Government users acquire the Software with only those rights as set forth herein. Manufacturer is Scott Technologies, Inc. d/b/a Scott Health and Safety, 4320 Goldmine Road, Monroe, NC 28110.9.  Equitable Relief. You acknowledge that, at the time this Agreement is entered, it would be impossible or inadequate to measure and calculate all of SCOTT’s damages for the breach of certain provisions of this Agreement, including without limitation Section 3.1, and that it would require a court of competent jurisdiction to ascertain SCOTT’s damages. Accordingly, if you breach or threaten to breach any of your obligations, other than payment when due, SCOTT shall be entitled, without showing or proving any actual damage sustained, to a stipulated tempo-rary restraining order, and shall thereafter be entitled to apply for a preliminary injunction, permanent injunction, and/or order compelling specic performance, to prevent the breach of your obligations under this Agreement. Nothing in this Agreement shall be interpreted as prohibiting SCOTT from pursuing or obtain-ing any other remedies as otherwise available to it for such actual or threatened breach, including recovery of damages.END USER LICENSE AGREEMENT CONTINUED...
Page 35 of 36P/N 595289-01 Rev B  5/1510.  Governing Law/Jurisdiction. This Agreement shall be exclusively interpreted, construed and enforced in all respects in accordance with the laws of the State of North Carolina (U.S.A.) without reference to its choice of law rules. Notwithstand-ing the foregoing, no action brought by either Party against the other for breach of this Agreement shall be limited to breach of contract remedies and either Party may bring any additional cause(s) of action that would otherwise be available to it, including and only as applicable based on the facts presented, copyright infringement pursuant to Title 17 of the United States Code. You hereby expressly and specically waives any objection You may have, pursuant to the Eleventh Amendment to the United States Constitution or otherwise, to the jurisdiction of, or any award that could be granted by, the United States Federal Courts.11.  General. As used in this Agreement “Afliate” means each: (i) individual, corpo-ration, partnership, limited liability company, limited liability partnership, practice, association, joint stock company, trust, unincorporated organization or other venture or business vehicle (each an “Entity”) in which SCOTT directly or benecially owns a twenty percent (20%) or greater equity interest; or (ii) Entity which, directly or indirectly, is in control of, is controlled by or is under common control with SCOTT; or (iii) the ultimate parent of SCOTT and any Entity which is owned or controlled, directly or indirectly, by the ultimate parent; or (iv) Entity that is a legally recognized franchisee or distributor of SCOTT. For the purpose of this denition, control of an Entity includes the direct or indirect power, whether or not exercised: (a) to vote fty percent (50%) or more of the securities or other interests having ordinary voting power for the election of directors or other managing authority of such Entity; or (b) to direct or cause the direction of the management or policies of such Entity, whether through ownership of voting securities, partnership interest or equity, by contract or otherwise. This Agreement sets forth the entire agreement and understanding of the parties relating to the subject matter herein and merges and supersedes all prior agreements, writings, commitments, discussions and understandings between them, including without limitation any license agreement embedded in the software. No modication of or amendment to this Agreement, nor any waiver of any rights under this Agreement, shall be effective unless in writing signed by the parties. If any provision of this Agreement is held by a court of competent jurisdiction to be invalid, prohibited, or unenforceable in any jurisdiction, such provision shall, as to such jurisdiction, be ineffective solely in such jurisdiction and only to the limited extent it is found to be invalid, prohibited, or unenforceable, and each and every remaining provision of this Agreement shall remain in full force and effect as if such invalid, prohibited, or unenforceable provision never had been included.. This Agreement shall be construed within its fair meaning and no inference shall be drawn against the drafting Party in interpreting this Agreement.YOU HEREBY ACKNOWLEDGE THAT YOU HAVE READ THIS AGREEMENT, UNDERSTAND IT, AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS.NOTICE:THESE USER INSTRUCTIONS ARE TO BE REMOVED ONLY BY THE END USER.
Page 36 of 36P/N 595289-01 Rev B   5/15SCOTT SAFETYMonroe Corporate CenterPO Box 569Monroe, NC 28111Telephone 1-800-247-7257Fax (704) 291-8330www.scottsafety.comPrinted in USASCOTT SAFETYLIMITED WARRANTY ON NFPA 1981 AND NFPA 1982, 2013 COMPLIANT AIR-PAK SCBA 2.2/4.5/5.5 PRODUCTSScott Safety (SCOTT) warrants NFPA 1981 and NFPA 1982, 2013 Compliant AIR-PAK SCBA 2.2/4.5/5.5 PRODUCTS (THE PRODUCTS) to be free from defects in workmanship and materials for a period of ten (10) years from the date of original manufacture by SCOTT. This warranty applies to all components of THE PRODUCTS including all accessories and optional equipment purchased and supplied at the time of original sale of THE PRODUCTS, EXCEPT pressure reducers, electrically operated devices, consumable supplies and carrying cases. SCOTT warrants all pressure reducers supplied with THE PRODUCTS to be free from defects in workmanship and materials for a period of fteen (15) years from the date of original manufacture by SCOTT. SCOTT warrants all electrically operated devices supplied with THE PRODUCTS to be free from defects in workmanship and materials for ve (5) years from the date of original manufacture by SCOTT. SCOTT further warrants all communications devices, unused consumable supplies, and carrying cases supplied with THE PRODUCTS to be free from defects in workmanship and materials for one (1) year from the date of original manufacture by SCOTT. SCOTT’s obligation under this warranty is limited to replacing or repairing (at SCOTT’s option) THE PRODUCTS or components shown to be defective in either workmanship or materials.Only personnel of SCOTT or, when directed by SCOTT, authorized SCOTT agents are authorized to perform warranty obligations. This warranty does not apply to defects or damage caused by any repairs of or alterations to THE PRODUCTS made by owner or any third party unless expressly permitted by SCOTT product manuals or by written authorization from SCOTT. To obtain performance under this warranty, and as a condition precedent to any duty of SCOTT, the purchaser must return such products to SCOTT, a SCOTT authorized distributor or a SCOTT authorized service center. Any product returned to SCOTT shall be sent to “SCOTT SAFETY” (Attn: Warranty Claim Dept.), P.O. Box 569, Monroe, NC 28111.This warranty does not apply to any malfunction of or damage to THE PRODUCTS resulting from accident, alteration, misuse or abuse.THIS WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN ADDITION, SCOTT EXPRESSLY DISCLAIMS ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES IN ANY WAY CONNECTED WITH THE SALE OR USE OF SCOTT SAFETY PRODUCTS, AND NO OTHER FIRM OR PERSON IS AUTHORIZED TO ASSUME ANY SUCH LIABILITY.

Navigation menu