4RF N0700AAAA0000A Aprisa XE 700-bbb-vv User Manual Aprisa XE
4RF Limited Aprisa XE 700-bbb-vv Aprisa XE
4RF >
Contents
- 1. User Manual 1
- 2. User Manual 2
User Manual 2
Protected Terminals | 181 11. Protected Terminals Monitored Hot Stand By (MHSB) This section describes configuring the protected terminal in MHSB mode. A protected terminal in MHSB mode comprises two radios interconnected using a MHSB switch. This MHSB switch comprises one RF switch and up to four tributary switches depending on the number of tributaries requiring switching: The MHSB switch protect terminals against any single failure in one radio. It also monitors the alarm output of each radio and switches between radios if major radio link alarms occur. The MHSB switch will not allow a switch to a faulty radio. The MHSB switch uses a CPU to monitor the alarm status received from both the connected radios' alarm ports. When a relevant major radio link alarm is detected on the active radio (that is, transmitter, receiver, power supply or modem), the CPU switches a bank of relays that switches all the interfaces and the transmit port from the main radio to a functioning stand-by radio. The stand-by radio now becomes the active radio. The MHSB switch has a hysteresis of 30 seconds to prevent switching on short alarm transients. The tributary switch and the RF switch are both a 19-inch rack-mount 1U high chassis. The MHSB switch option is available for all Aprisa XE frequency bands. Aprisa XE User Manual 182 | Protected Terminals Tributary Switch Front Panel No. Description Explanation Power supply input Input for DC power or AC power Protective earth M5 terminal intended for connection to an external protective conductor for protection against electric shock in case of a fault Interface ports Port for connecting to customer interface equipment Radio A interfaces These connect to the interface ports on radio A Radio B interfaces These connect to the interface ports on radio B Console For factory use only Ethernet Port for connecting to customer Ethernet network. This port is also used to set up and manage the radios remotely over an IP network Radio A Ethernet Connects to an Ethernet port on radio A Radio B Ethernet Connects to an Ethernet port on radio B 10 Alarms Alarm input/output connections for customer equipment 11 Radio A alarms Connects to the alarm port on radio A 12 Radio B alarms Connects to the alarm port on radio B 13 RF SW Provides power and signalling to the RF switch 14 Mode switch Three-position locking toggle switch to set the MHSB switch into automatic mode or radio A / radio B test mode 15 LEDs Mode and status LEDs Aprisa XE User Manual Protected Terminals | 183 Tributary Protection Switch LEDs LED Colour Appearance Explanation Green Solid The radio is active and is OK Green Flashing The radio is in standby mode and is OK Red Solid The radio is active and there is a fault No colour (off) The tributary switch is in 'slave' mode and the switching is controlled by the master tributary switch Red Flashing The radio is in standby mode, and there is a fault Green Solid The radio is active and is OK Green Flashing The radio is in standby mode and is OK Red Solid The radio is active and there is a fault No colour (off) The tributary switch is in 'slave' mode and the switching is controlled by the master tributary switch Red Flashing The radio is in standby mode, and there is a fault Green Solid The tributary protection switch is in 'auto' mode Green Flashing The tributary protection switch is in 'slave' mode Red Solid The tributary protection switch is in 'manual' mode (A or B) Blue Solid Indicates that there is power to the tributary protection switch On RF Switch Front Panel No. Description Explanation Radio QMA QMA connectors for connecting the protected radios Protective earth M5 terminal intended for connection to an external protective conductor for protection against electric shock in case of a fault Antenna port N-type female connector for connection to the antenna feeder cable. This view shows an internally mounted duplexer. If an external duplexer is fitted, the antenna port will be on the external duplexer Slave tributary switch outputs Connects to secondary tributary switch for control of additional interfaces Tributary switch Connects the RF switch to the tributary switch (the master if more than one tributary switch is required) LEDs Status LEDs Aprisa XE User Manual 184 | Protected Terminals RF Protection Switch LEDs LED Colour Appearance Explanation Tx A Green Solid RF is being received from radio A Tx B Green Solid RF is being received from radio B On Blue Solid Indicates that there is power to the RF protection switch Slave Tributary Switches Each tributary switch protects up to eight ports. Up to three slave tributary switches may be added to a MHSB terminal to protect up to 32 ports. Each slave tributary switch is interconnected by means of the slave tributary switch ports on the RF switch, as shown below. Note: A tributary switch that is operating as a slave (rather than a master) has a RJ-45 V.24 loopback connector plugged into the console port. If the connector is missing, contact Customer Support. Alternatively, you can make this connector. Follow the standard pinouts for a V.24 RJ-45 connection (see ‘QV24 Interface connections’ on page 273). Aprisa XE User Manual Protected Terminals | 185 MHSB Cabling The two radios are interconnected as follows: CAUTION: Do not connect Transmit to Receive or Receive to Transmit as this may damage the radio or the MHSB switch. Cables supplied with MHSB The following cables are supplied with a MHSB terminal: Ethernet interface: RJ-45 ports standard TIA-568A patch cables . Alarm interface: RJ-45 ports standard TIA-568A patch cables. RF ports: two QMA male patch cables are supplied. MHSB Power Supply See ‘DC Power Supply’ on page 37 and ‘AC Power Supply’ on page 40. Aprisa XE User Manual 186 | Protected Terminals Configuring the Radios for Protected Mode The MHSB switch does not require any special software. However, the radios connected to the MHSB switch must be configured to work with the MHSB switch. This sets the alarm outputs and inputs to function in MHSB mode. You must configure the interfaces of both radios connected to the MHSB switch identically. To perform this, you can either connect directly to the radio or use the test mode of the MHSB switch. MHSB Terminal IP Addresses Before configuring the link, you must ensure that the two independent links have correctly configured IP address details. All four radios in the protected link must be on the same subnet. Example of MHSB IP addressing Aprisa XE User Manual Protected Terminals | 187 Mounting the MHSB Radios and Switches Once the IP addresses are correctly configured, it is important to connect the A and B radios' Ethernet and Alarm ports correctly. In general, mount radio A above the MHSB switch and radio B below the MHSB switch: There is an Ethernet connection between any of the four Ethernet ports on each radio and the Ethernet port on the Tributary switch. There is also a connection between radio A and radio B, which ensures Ethernet traffic is maintained if a radio loses power. The Ethernet port on the protection switch can be connected to an Ethernet hub or switch to allow multiple connections. Important: The management Ethernet capacity on each of the four radios in the protected terminal must be identical for remote communications to work and there should only be one IP connection to the management network (via the tributary switch Ethernet port). Aprisa XE User Manual 188 | Protected Terminals Configuring the Terminals for MHSB It is recommended that you configure the local and remote A side first, then the local and remote B side. Both the local A and B radios must be configured identically, and both the remote A and B radios must be configured identically. Tip: As illustrated below, you may find it helpful to have two browser sessions running simultaneously. You can then easily see both the A and B sides of the protected link. To configure MHSB operation: 1. Select Link > Maintenance > MHSB. 2. Enable MHSB mode. 3. Select whether the radio is A or B. Ensure that the radio connected to the A side of the protection switch (normally above the MHSB switch) is set to Radio A and the radio connected to the B side of the protection switch (normally below the MHSB switch) is set to Radio B. In the event of a power outage, the radios will switch over to the A side of the protection switch when the power is restored. The A side is also the default active side. 4. When you have made your changes, click Apply to apply changes or Reset to restore the previous configuration. 5. Repeat steps 2 to 4 for the other side of the protected link. Aprisa XE User Manual Protected Terminals | 189 Clearing MHSB Alarms If a switchover event occurs, the OK LED on the front panel and on the Terminal status and menu bar in SuperVisor changes to amber. 1. Select Clear Switched Alarm from the MHSB Command drop-down list. 2. Click Apply to apply changes or Reset to reset the page. Note: When MHSB mode is enabled, external alarm input 2 is used by the protection system to carry alarms from the protection switch to the radio. In MHSB mode, therefore, only external alarm input 1 is available for user alarms. Aprisa XE User Manual 190 | Protected Terminals Hitless Space Diversity (HSD) HSD provides hitless RF receive path protection and hot standby transmitter redundancy. It is typically deployed for paths where high path availability is required. An Aprisa XE hitless space diversity terminal comprises two radio terminals, radio A and radio B. Radio A is the primary radio which is fitted with the interface cards and connects to antenna A. Antenna A always carries the transmitted signal and the received signal for Radio A. Radio B is the secondary radio the receiver of which connects to antenna B. The transmitter in this radio is the standby transmitter. In the event of a radio A active transmitter failure, radio B transmitter becomes active. Antenna B only carries the received signal for Radio B. This antenna is physically separated on the tower by a pre-determined distance from Antenna A. As both radios have a receive path, traffic from the path with the best received bit error rate is routed to the customer interfaces in radio A. In an HSD terminal, a HSD Protection Switch Card (PSC) is always fitted in slot H in Radio A and a HSD Protection Interface Card (PIC) is always fitted in slot H in Radio B. The PSC card has a card front switch which controls the hardware setting of the HSD system Active Radio (Auto Select, Radio A or Radio B). Customer interfaces are provided on radio A only in interface slots A to G. Interface connections to Ethernet and the external alarm inputs and outputs are also provided on radio A only. Aprisa XE User Manual Protected Terminals | 191 HSD Terminal Cabling The two HSD radios are interconnected as follows: Cables Supplied with HSD Terminal The following cables are supplied with a HSD terminal: RF cable A 110 mm QMA female to QMA female low loss RF cable is required to interconnect between the TX ports of both radio A and radio B. This cable carries the radio B transmitter output to the radio A transmitter switch. Ethernet Cable A 200 mm RJ45 to RJ45 Ethernet cable between the Ethernet ports of radio A and radio B. This cable carries management IP traffic between radio A and radio B. Traffic Cable A 200 mm RJ45 to RJ45 Ethernet cable between the PSC and PIC. This cable carries all user traffic between Radio A and Radio B. Aprisa XE User Manual 192 | Protected Terminals HSD Terminal IP Addresses Each radio in the HSD link is assigned a unique IP address. All four radios in the HSD link must be on the same subnet. The IP address of the four terminals can only be changed by logging into the relevant radio A or radio B. When the IP addresses have been setup, an ethernet connection to any of the four radios can access all four radios in the HSD link. The usual ethernet connection is to the near end Radio A (see ‘IP Addressing of Terminals’ on page 53). Example of IP addressing Aprisa XE User Manual Protected Terminals | 193 Configuring HSD Terminals To simplify the management and configuration of the HSD terminals, SuperVisor provides four windows which display the parameters for all four radios, the local and remote, radios A and B. The HSD System menu item displays the four windows. When a parameter is changed in the four window mode, the relevant parameter is automatically changed to the same setting on the corresponding radio e.g. if a radio A modulation type is changed, the radio B modulation type is also changed to the same setting. The Local and Remote menus continue to display the parameters for the local and remote radios for the near end terminal logged into. The majority of SuperVisor HSD System pages contain the same parameters and controls as the standard 1+0 XE terminal. The main exceptions are the HSD Control page and the HSD Performance Summary page. Aprisa XE User Manual 194 | Protected Terminals HSD Active Radio Control The HSD system ‘Active Radio’ control determines if the selection of Radio A or Radio B is automatic or manual. This controls both the radio transmitters and receivers. The Active Radio can be set with the hardware switch on the PSC card front or with the SuperVisor software control. The last change of hardware / software control determines the state of the HSD system. The SuperVisor software control will always reflect the state of the HSD system. After terminal startup or reboot, the state of the PSC mode switch determines the setting used by the system and the SuperVisor software control is set to reflect the state of the HSD system. The PSC card has two card front LEDs which indicate the status of the HSD system: PSC Mode Switch Hardware Control Change Software Control Change LED A LED B LED A LED B Radio A Solid Amber Off Flashing Amber Off Auto Select Solid Green Solid Green Flashing Amber Flashing Amber Off Solid Amber Off Flashing Amber Radio B To set the HSD controls: 1. Select HSD System > Maintenance > Control. 2. Set the Active Radio parameter. Active Radio Mode of Operation Auto Select (default) Automatic mode: The hitless receive will select traffic from the receive path of best performance The HSD system will switch to the standby transmitter if the active transmitter fails (TX failure alarm) Radio A Only Manual selection of radio path A only for both the transmitter and receiver i.e. no automatic switching Radio B Only Manual selection of radio path B only for both the transmitter and receiver i.e. no automatic switching Note: There is no timeout for a manual selection of the Active Radio setting (Radio A only or Radio B only) but a ‘Mode Switch Software Override’ alarm will warn if the software has overwritten the PSC Mode Switch. Aprisa XE User Manual Protected Terminals | 195 3. Set the Parameter Compare Checking. Parameter Compare Checking Option On (default) Any mismatch in parameters shown in Terminal Settings between Radio A and Radio B will generate a Parameter Mismatch alarm. Off No Parameter Mismatch alarm will be generated. To view the HSD System Performance Summary: 1. Select HSD System > Performance > Summary. Field Explanation Terminal UCEs The total number of HSD terminal uncorrectable blocks since the last reset Terminal Errored seconds The total number of HSD terminal operational seconds with errored traffic since the last reset Terminal Error free seconds The total number of HSD terminal error free operational seconds since the last reset Terminal BER The system will report an estimated HSD terminal Bit Error Rate up to a maximum of 1 in 1021 Active Transmitter Dislays the current active transmitter (TxA or TxB) Click Reset Counters to reset the error counters to zero. Aprisa XE User Manual In-Service Commissioning | 197 12. In-Service Commissioning Before You Start When you have finished installing the hardware, RF and the traffic interface cabling, the system is ready to be commissioned. Commissioning the terminal is a simple process and consists of: 1. Powering up the terminals 2. Configuring both the local and remote terminals using SuperVisor 3. Aligning the antennas 4. Synchronizing the terminals 5. Testing the link is operating correctly. As a minimum, conduct the suggested tests to ensure correct operation. More extensive testing may be required to satisfy the end client or regulatory body requirements. 6. Connecting up the client or user interfaces What You Will Need Appropriately qualified commissioning staff at both ends of the link. Safety equipment appropriate for the antenna location at both ends of the link. Communication equipment, that is, mobile phones or two-way radios. SuperVisor software running on an appropriate laptop, computer, or workstation at one end of the link. Tools to facilitate loosening and re-tightening the antenna pan and tilt adjusters. Predicted receiver input levels and fade margin figures from the radio link budget (You can use Surveyor (see ‘Path planning’ on page 23) to calculate the RSSI, fade margin, and availability). Aprisa XE User Manual 198 | In-Service Commissioning Applying Power to the Terminals WARNING: Before applying power to a terminal, ensure you have connected the safety earth and antenna cable. Apply power to the terminals at each end of the link. When power is first applied, all the front panel LEDs will illuminate red for several seconds as the system initializes. After the system is initialized, the OK LED on the front panel should illuminate green and if the terminals are correctly configured, the TX and RX LED should also be illuminated green. If the RX LED is: Red the antennas are may be significantly mis-aligned with no signal being received Amber the antennas may be roughly aligned with some signal being received Green the antennas are well-aligned and adequate signal is being received to create a reliable path If the TX LED is: Red the transmitter is faulty Amber there is a fault in the antenna connection or feeder cable Green the transmitter is working normally Review the Link Configurations Using SuperVisor 1. Connect a PC, with SuperVisor installed, to both terminals in the link. 2. Log into the link. 3. Select Link > Summary and confirm the following basic information: Terminal IP address(es) Terminal TX and RX frequencies RSSI (dBm) TX power (dBm) SNR (dBm) Note: If the terminals have not already been configured, refer to ‘Configuring the terminal’ on page 69, ‘Configuring the traffic interfaces’ on page 91, and ‘Configuring the traffic cross connections’ on page 145. Aprisa XE User Manual In-Service Commissioning | 199 Antenna Alignment For any point-to-point link, it is important to correctly align the antennas to maximize the signal strength at both ends of the link. Each antenna must be pointing directly at the corresponding antenna at the remote site, and they must both be on the same polarization. The antennas are aligned visually, and then small adjustments are made while the link is operating to maximize the received signal. Directional antennas have a radiation pattern that is most sensitive in front of the antenna, in line with the main lobe of the radiation pattern. There are several other lobes (side lobes) that are not as sensitive as the main lobe in front of the antenna. For the link to operate reliably, it is important that the main lobes of both antennas are aligned. If any of the side lobes are aligned to the opposite antenna, the received signal strength of both terminals will be lower, which could result in fading. If in doubt, check the radiation patterns of the antennas you are using. Checking the Antenna Polarization Check that the polarization of the antennas at each end of the link is the same. Antenna polarization of grid antennas are normally indicated by an arrow or with ‘H’ and ‘V’ markers (indicating horizontal and vertical). On Yagi antennas, ensure the orientation of the elements are the same at each end of the link. Transmit frequency and power, and antenna polarization would normally be defined by a regulatory body, and typically licensed to a particular user. Refer to your license details when setting the antenna polarization. Aprisa XE User Manual 200 | In-Service Commissioning Visually Aligning Antennas 1. Stand behind the antenna, and move it from side to side until it is pointing directly at the antenna at the remote site. The remote antenna may be made more visible by using a mirror, strobe light, or flag. If the remote end of the link is not visible (due to smoke, haze, or local clutter, etc), align the antenna by using a magnetic compass. Calculate the bearing using a scale map of the link path. When setting the antenna on the desired bearing ensure that you use the appropriate true-north to magnetic-north offset. Also ensure that the compass reading is not affected by standing too close to metallic objects. 2. Once the antenna is pointing at the remote antenna, tighten the nuts on the U-bolt or antenna clamp just enough to hold it in position. Leave the nuts loose enough so that small adjustments can still be made. Check that the antenna is still pointing in the correct direction. 3. Move the antenna up or down until it is pointing directly at the remote site. 4. Tighten the elevation and azimuth adjustment clamps. 5. Mark the position of the antenna clamps so that the antenna can be returned to this rough aim point easily when accurately aligning the antennas. 6. Repeat steps 1-5 at the opposite site. Note: Low gain antennas need less adjustment in elevation as they are simply aimed at the horizon. They should always be panned horizontally to find the peak signal. Aprisa XE User Manual In-Service Commissioning | 201 Accurately Aligning the Antennas Once the antennas are visually aligned, accurately align both antennas by carefully making small adjustments while monitoring the RSSI. This will give the best possible link performance. Note: Remember that it is important to align the main radiation lobes of the two antennas to each other, not any side lobes. It may be easier to perform this procedure if you can communicate with someone at the remote site by telephone, mobile, or two-way radio. 1. Connect a laptop PC running SuperVisor software and power up the terminals at both ends of the link. Select Link > Performance > Summary so that you can see the RSSI indication for the local terminal. Alternatively, use the RSSI test point on the front panel together with a multimeter (see ‘Measuring the RSSI’ on page 202). 2. Move the antenna through a complete sweep horizontally (known as a 'pan') either side of the point established in the visual alignment process above. Note down the RSSI reading for all the peaks in RSSI that you discover in the pan. 3. Move the antenna to the position corresponding to the maximum RSSI value obtained during the pan. Move the antenna horizontally slightly to each side of this maximum to find the two points where the RSSI drops slightly. 4. Move the antenna halfway between these two points and tighten the clamp. 5. If the antenna has an elevation adjustment, move the antenna through a complete sweep (known as a 'tilt') vertically either side of the point established in the visual alignment process above. Note down the RSSI reading for all the peaks in RSSI that you discover in the tilt. 6. Move the antenna to the position corresponding to the maximum RSSI value obtained during the tilt. Move the antenna slightly up and then down from the maximum to find the two points where the RSSI drops slightly. 7. Move the antenna halfway between these two points and tighten the clamp. 8. Recheck the pan (steps 2-4) and tighten all the clamps firmly. 9. Perform steps 1-8 at the remote site. Aprisa XE User Manual 202 | In-Service Commissioning Measuring the RSSI Measure the RSSI value with a multimeter connected to the RSSI test port on the front of the terminal (see ‘Front panel connections and indicators’ on page 31). 1. Insert the positive probe of the multimeter into the RSSI test port, and clip the negative probe to the chassis of the terminal (earth). 2. Pan and tilt the antenna until you get the highest VDC reading. The values shown in the table below relate the measured VDC to the actual received signal level in dBm regardless of bandwidth and frequency. RSSI test port value (VDC) RSSI reading (dBm) RSSI test port value (VDC) RSSI reading (dBm) RSSI test port value (VDC) RSSI reading (dBm) 0.000 - 100 0.675 - 73 1.350 - 46 0.025 - 99 0.700 - 72 1.375 - 45 0.050 - 98 0.725 - 71 1.400 - 44 0.075 - 97 0.750 - 70 1.425 - 43 0.100 - 96 0.775 - 69 1.450 - 42 0.125 - 95 0.800 - 68 1.475 - 41 0.150 - 94 0.825 - 67 1.500 - 40 0.175 - 93 0.850 - 66 1.525 - 39 0.200 - 92 0.875 - 65 1.550 - 38 0.225 - 91 0.900 - 64 1.575 - 37 0.250 - 90 0.925 - 63 1.600 - 36 0.275 - 89 0.950 - 62 1.625 - 35 0.300 - 88 0.975 - 61 1.650 - 34 0.325 - 87 1.000 - 60 1.675 - 33 0.350 - 86 1.025 - 59 1.700 - 32 0.375 - 85 1.050 - 58 1.725 - 31 0.400 - 84 1.075 - 57 1.750 - 30 0.425 - 83 1.100 - 56 1.775 - 29 0.450 - 82 1.125 - 55 1.800 - 28 0.475 - 81 1.150 - 54 1.825 - 27 0.500 - 80 1.175 - 53 1.850 - 26 0.525 - 79 1.200 - 52 1.875 - 25 0.550 - 78 1.225 - 51 1.900 - 24 0.575 - 77 1.250 - 50 1.925 - 23 0.600 - 76 1.275 - 49 1.950 - 22 0.625 - 75 1.300 - 48 1.975 - 21 0.650 - 74 1.325 - 47 2.000 - 20 Aprisa XE User Manual In-Service Commissioning | 203 Checking Performance The amount of testing performed on the completed installation will depend on circumstances. Some customers may need to prove to a local licensing regulatory body that the link complies with the license provisions. This may require special telecommunications test equipment to complete these tests. Most customers simply want to confirm that their data traffic is successfully passing over the link, or that the customer interfaces comply with known quality standard. However, the most important performance verification checks are: Receive input level Fade margin Long-term BER Checking the Receive Input Level The received signal strength at the local terminal is affected by many components in the system and has a direct relationship with the resulting performance of the link. A link operating with a lower than expected signal strength is more likely to suffer from degraded performance during fading conditions. The receive input level of a link is normally symmetrical (that is, similar at both ends). 1. Compare the final RSSI figure obtained after antenna alignment with that calculated for the link. 2. If the RSSI figure is in excess of 3 dB down on the predicted level, recheck and correct problems using the table below and then recheck the RSSI. Alternatively, recheck the link budget calculations. Possible cause Terminal(s) Is the terminal operating on the correct frequency? Local & remote Is the remote terminal transmit power correct? Remote Are all the coaxial connectors tight? Local & remote Is the antenna the correct type, that is, gain and frequency of operation? Local & remote Is the antenna polarized? Local & remote Is the antenna aligned? Local & remote Is the path between the terminals obstructed? Note: If following the above steps does not resolve the situation, contact Customer Support for assistance. 3. Record the RSSI figure on the commissioning form. 4. Repeat steps 1 to 2 for the other end of the link. Aprisa XE User Manual 204 | In-Service Commissioning Checking the Fade Margin The fade margin is affected by many components in the system and is closely related to the received signal strength. A link operating with a lower than expected fade margin is more likely to suffer from degraded performance during fading conditions. A reduced fade margin can be due to operating the link too close to the noise floor, or the presence of external interference. The fade margin of a link can be asymmetrical (that is, different at each end). Possible causes of low fade margin are as follows: Problem Terminal Low receive signal strength (see above table) Local and Remote Interfering signals on the same, or very close to, the frequency of the local terminal receiver. Local Intermodulation products that land on the same or very close to the frequency of the local terminal receiver. Local or Remote Operating near the local receiver noise floor Local To check the fade margin: 1. Confirm (and correct if necessary) the receive input level (see the previous test). Note: If the receive input level is lower than expected, the fade margin may also be low. 2. Select Link > Performance > Summary and check the current BER of the link in its normal condition is better than 10-6 (If necessary, clear out any extraneous errors by clicking Reset Counters). 3. Check the signal to noise (S/N) indication on the Link > Performance > Summary page. This shows the quality of the signal as it is being processed in the modem. It should typically be better than 30 dB. If it is less than 25 dB, it means that either the RSSI is very low or in-band interference is degrading the S/N performance. 4. Temporarily reduce the remote site's transmit power using either an external attenuator or SuperVisor (Remote > Terminal > Basic). Note: Ideally, the transmit power of the remote site should be reduced by up to 20 dB, which will require the use of an external 50 ohm coaxial attenuator capable of handling the transmit power involved. In the absence of an attenuator, reduce the transmit power using SuperVisor. 5. Check and note the current BER of the link in its now faded condition (Again, if necessary, clear out any extraneous errors (introduced by the power reduction step above) by clicking Reset Counters). 6. Compare the unfaded and faded BER performance of the link (steps 2 and 4). Continue to reduce the remote transmit power until either the BER drops to 10 -6 or the remote transmitter power has been reduced by 20 dB. Note: The fade margin of the link is expressed as a number (of dB) that the link can be faded (transmitter power reduced) without reducing the BER below operating specifications (1 * 10-6 BER). A 20 dB fade margin is adequate for most links. Aprisa XE User Manual In-Service Commissioning | 205 7. Record the fade margin and SNR results on the commissioning form. Note: If the transmit power is reduced using SuperVisor rather than an external attenuator, the fade margin should be recorded as ‘Greater than x dB’ (where x = the power reduction). 8. Restore the remote terminal transmit power to normal. 9. Repeat steps 1 to 7 for the other end of the link. Note: If following all the guidelines above does not resolve the situation, contact Customer Support for assistance. Checking the Long-Term BER The BER test is a measure of the stability of the complete link. The BER results of a link can be asymmetrical (that is, different at each end). 1. Select Link > Performance > Summary and check the current BER and error counters of the link. If necessary, clear out any extraneous errors by selecting Reset Counters. 2. Wait 15 minutes, and check the BER display and error counters again. If there are a small number of errors and the BER is still better than 1 x 10-9, continue the test for 24 hours. If there are a significant number of errors, rectify the cause before completing the 24 hour test. Note: It is normal to conduct the BER test in both directions at the same time, and it is important that no further work be carried out on the equipment (including the antenna) during this period. 3. The BER after the 24 hour test should typically be better than 1 x 10-8. 4. Record the BER results on the commissioning form. Bit Error Rate Tests A Bit Error Rate (BER) test can be conducted on the bench, (see ‘Bench Setup’ on page 43). Attach the BER tester to the interface port(s) of one terminal, and either another BER tester or a loopback plug to the corresponding interface port of the other terminal. This BER test can be carried out over the Ethernet, E1 / T1, V.24 or HSS interfaces. It will test the link quality with regard to user payload data. CAUTION: Do not apply signals greater than -20 dBm to the antenna as they can damage the receiver. In a bench setup, there must be 60 - 80 dB at up to 2 GHz of 50 ohm coaxial attenuation (capable of handling the transmit power) between the terminals’ antenna connectors. Aprisa XE User Manual 206 | In-Service Commissioning Additional Tests Depending on license requirements or your particular needs, you may need to carry out additional tests, such as those listed below. Refer to the relevant test equipment manuals for test details. Test Test equipment required TX power output measurements (at TX and duplexer outputs) Power meter TX spectrum bandwidth Spectrum analyzer TX spectral purity or harmonic outputs Spectrum analyzer TX center frequency Frequency counter or spectrum analyzer Bulk capacity BER test BER tester LAN throughput or errors LAN tester G.703 / HDB3 waveforms Digital oscilloscope Serial interface BER BER tester Audio quality PCM4 or SINAD test set Aprisa XE User Manual In-Service Commissioning | 207 Checking the Link Performance For a graphical indication of the link performance, you can use the constellation analyzer. The 'dots' are a graphical indication of the quality of the demodulated signal. Small dots that are close together indicate a good signal. If the dots become spaced further apart, this indicates that the signal quality is degrading. This signal quality degradation can be caused by low Rx signal level due to, for example: external interference failure of any of the following: modem, receiver, far end transmitter, an antenna (either end), a feeder or connector (for example, due to water damage) path issues such as multipath fading or obstructions To check the performance of the link using the constellation analyzer: 1. Select Link or Local or Remote > Performance > Constellation. 2. Click Start to start the constellation analyzer. While the constellation analyzer is running, the terminal will temporarily stop collecting error performance statistics. If you want to run the constellation analyzer anyway, click OK when you see this warning message: 3. Click Stop to stop the constellation analyzer. The terminal automatically resumes collecting error performance statistics. Aprisa XE User Manual 208 | In-Service Commissioning Viewing a Summary of the Link Performance To view the performance summary for a terminal: Select Link or Local or Remote > Performance > Summary. Field Explanation Link Performance Correctable errors The total number of correctable blocks since the last reset Uncorrectable errors The total number of uncorrectable blocks since the last reset SNR (dB) The Signal to Noise Ratio of the link in dB RSSI (dBm) The Received Signal Strength Indication at the Rx input in dBm Errored seconds The total number of operational seconds with errored traffic since the last reset Error free seconds The total number of error free operational seconds since the last reset BER The system will report an estimated Bit Error Rate up to a maximum of 1 in 1021 TX temperature The measured temperature in the transmitter module in °C RX temperature The measured temperature in the receiver module in °C Ethernet performance Transmitted packets The total number of transmitted Ethernet packets Received packets The total number of received Ethernet packets Received packet errors The total number of packets received with errors Click Reset Counters to reset the error counters to zero. Aprisa XE User Manual In-Service Commissioning | 209 Saving the History of the Link Performance Link performance history data is stored in a rolling buffer which can be saved as a *.cvs file (default filename is savedPerformanceHistory.csv). The maximum history data buffer is 1 week of 1 hour records and the last hour is displayed in minute records. The parameters saved are: Date / Time SNR (minimum over period) SNR (average over period) SNR (maximum over period) RSSI (minimum over period) RSSI (average over period) RSSI (maximum over period) BER (value at end of period) UCEs count (value at end of period) Transmitter temperature (value at end of period) To save the history of the link performance for a terminal: Select Local > Performance > Save History. Example of file (simulated fade data): PREVIOUS WEEK TIME Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr … 6 09:44:50 2009 6 10:44:50 2009 6 11:44:50 2009 6 12:44:51 2009 6 13:44:51 2009 6 14:44:51 2009 SNR min (dB) 35.14 35.14 35.14 15.31 22.52 16.20 SNR avg (dB) 35.26 35.26 35.26 25.77 22.75 26.05 SNR max (dB) 35.39 35.40 35.40 58.54 22.89 54.61 RSSI min (dBm) -54.00 -54.00 -54.00 -114.00 -84.10 -87.10 RSSI avg RSSI max (dBm) (dBm) -54.00 -54.00 -53.90 -53.90 -53.90 -53.90 -77.00 -54.00 -83.70 -83.60 -77.40 -60.20 SNR min (dB) 22.52 22.55 22.50 22.50 22.54 22.52 22.48 22.49 22.48 22.50 22.61 22.46 22.46 22.47 22.48 22.49 16.20 16.23 35.10 35.08 35.07 35.06 35.06 35.09 35.07 SNR avg (dB) 28.38 25.67 23.52 24.35 22.73 26.67 30.19 28.87 30.65 29.99 29.78 25.70 26.96 24.71 30.19 25.97 22.94 26.84 40.60 39.17 36.63 36.68 35.34 36.28 42.56 SNR max (dB) 22.75 22.75 22.75 22.78 22.77 22.75 22.79 22.74 22.74 22.75 22.76 22.74 22.75 22.75 22.73 22.75 54.61 49.90 35.24 35.28 35.26 35.24 35.25 35.24 35.28 RSSI min (dBm) -84.10 -84.10 -84.10 -84.10 -84.10 -84.10 -84.10 -84.10 -84.10 -84.00 -84.00 -84.10 -84.10 -84.10 -84.10 -84.20 -87.10 -87.00 -60.50 -60.50 -60.50 -60.60 -60.60 -60.50 -60.60 RSSI avg RSSI max (dBm) (dBm) -78.19 -83.80 -80.89 -83.80 -83.07 -83.70 -82.23 -83.70 -83.86 -83.80 -79.90 -83.80 -76.38 -83.70 -77.68 -83.80 -75.94 -83.80 -76.59 -83.80 -76.82 -83.80 -80.86 -83.90 -79.61 -83.80 -81.86 -83.80 -76.36 -83.80 -80.61 -83.80 -83.76 -83.90 -73.31 -60.30 -54.96 -60.30 -56.40 -60.30 -58.95 -60.20 -58.90 -60.30 -60.24 -60.30 -59.28 -60.30 -53.03 -60.30 BER 3.40E-12 3.39E-12 3.38E-12 1.58E-05 6.92E-06 9.67E-05 UCEs 144 144 144 1045 9912 72125 Tx Temp (deg C) 50 50 50 50 51 52 PREVIOUS HOUR TIME Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr Mon Apr … 6 14:11:51 2009 6 14:12:51 2009 6 14:13:51 2009 6 14:14:51 2009 6 14:15:51 2009 6 14:16:51 2009 6 14:17:51 2009 6 14:18:51 2009 6 14:19:51 2009 6 14:20:51 2009 6 14:21:51 2009 6 14:22:51 2009 6 14:23:51 2009 6 14:24:51 2009 6 14:25:51 2009 6 14:26:51 2009 6 14:27:51 2009 6 14:28:51 2009 6 14:29:51 2009 6 14:30:51 2009 6 14:31:51 2009 6 14:32:51 2009 6 14:33:51 2009 6 14:34:51 2009 6 14:35:51 2009 Aprisa XE User Manual BER 5.89E-06 5.86E-06 5.84E-06 5.81E-06 5.78E-06 5.75E-06 5.73E-06 5.71E-06 5.68E-06 5.66E-06 5.64E-06 5.62E-06 5.59E-06 5.57E-06 5.55E-06 5.53E-06 7.30E-06 6.67E-03 1.70E-03 9.13E-04 6.11E-04 4.52E-04 3.56E-04 2.92E-04 2.46E-04 UCEs 22821 23369 23847 24338 24855 25374 25918 26473 27007 27561 28167 28717 29237 29776 30368 30942 71751 72125 72125 72125 72125 72125 72125 72125 72125 Tx Temp (deg C) 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 52 210 | In-Service Commissioning To save the alarm history from the Remote terminal, login to the Remote terminal and Select Local > Alarms > Save History. Aprisa XE User Manual RSSI avg (dBm) Select Link or Local or Remote > Performance > Clear History. Aprisa XE User Manual 0.00 -10.00 -20.00 -30.00 -40.00 -50.00 -60.00 -70.00 To clear the history of the link performance for a terminal: -80.00 -90.00 Date / Time Mon Apr 6 14:26:51 2009 Mon Apr 6 14:27:51 2009 Mon Apr 6 14:28:51 2009 Mon Apr 6 14:29:51 2009 Mon Apr 6 14:30:51 2009 Mon Apr 6 14:31:51 2009 Mon Apr 6 14:32:51 2009 Mon Apr 6 14:33:51 2009 Mon Apr 6 14:34:51 2009 Mon Apr 6 14:35:51 2009 Mon Apr 6 14:27:51 2009 Mon Apr 6 14:28:51 2009 Mon Apr 6 14:29:51 2009 Mon Apr 6 14:30:51 2009 Mon Apr 6 14:31:51 2009 Mon Apr 6 14:32:51 2009 Mon Apr 6 14:33:51 2009 Mon Apr 6 14:34:51 2009 Mon Apr 6 14:35:51 2009 Mon Apr 6 14:24:51 2009 Mon Apr 6 14:23:51 2009 Mon Apr 6 14:22:51 2009 Mon Apr 6 14:21:51 2009 Mon Apr 6 14:20:51 2009 Mon Apr 6 14:19:51 2009 Mon Apr 6 14:18:51 2009 Mon Apr 6 14:26:51 2009 Date / Time Mon Apr 6 14:25:51 2009 Aprisa XE Link Performance Mon Apr 6 14:25:51 2009 Mon Apr 6 14:24:51 2009 Mon Apr 6 14:23:51 2009 Mon Apr 6 14:22:51 2009 Mon Apr 6 14:21:51 2009 Mon Apr 6 14:20:51 2009 Mon Apr 6 14:19:51 2009 Mon Apr 6 14:18:51 2009 Mon Apr 6 14:17:51 2009 Mon Apr 6 14:16:51 2009 Mon Apr 6 14:15:51 2009 Mon Apr 6 14:14:51 2009 Mon Apr 6 14:13:51 2009 Mon Apr 6 14:12:51 2009 Mon Apr 6 14:11:51 2009 Graph of Date / Time vs the average RSSI Mon Apr 6 14:17:51 2009 Mon Apr 6 14:16:51 2009 Mon Apr 6 14:15:51 2009 Mon Apr 6 14:14:51 2009 Mon Apr 6 14:13:51 2009 Mon Apr 6 14:12:51 2009 Mon Apr 6 14:11:51 2009 SNR avg (dB) In-Service Commissioning | 211 To create an Excel chart of the link performance for a terminal: 1. Open the *.csv file with Excel. 2. Select the ‘Time’ column and the column you wish to graph e.g. ‘SNR avg (dB)’ or ‘RSSI avg (dBm)’ 3. Select ‘Insert Chart’ from the Excel menu. Graph of Date / Time vs the average SNR Aprisa XE Link Performance 45.00 40.00 35.00 30.00 25.00 20.00 15.00 10.00 5.00 0.00 Maintenance | 213 13. Maintenance There are no user-serviceable components within the terminal. All hardware maintenance must be completed by 4RF or an authorized service centre. Do not attempt to carry out repairs to any boards or parts. Return all faulty terminals to 4RF or an authorized service centre. For more information on maintenance and training, please contact Customer Services. CAUTION: Electro Static Discharge (ESD) can damage or destroy the sensitive electrical components in the terminal. Routine Maintenance Every six or twelve months, for both ends of the link, you should record the RSSI and SNR levels as well as checking the following: Item What to check or look for Equipment shelter environment Water leaks Room temperature Excessive vibration Vermin damage Terminal mounting Firmly mounted Antenna cable connections Tight and dry Antenna cable and its supports Not loose or suffering from ultra-violet degradation Antenna and its mounting hardware Not loose, rusty or damaged Safety earth Connections tight Cabling intact DC system Connections tight Voltage in normal limits Batteries (if installed) Connections tight Electrolyte levels normal Aprisa XE User Manual 214 | Maintenance Terminal Upgrades You can upgrade all software for both terminals remotely (through a management network), which eliminates the need to physically visit either end of the link. A terminal is upgraded by accessing a running TFTP server (see ‘TFTP Upgrade Process’ on page 221). All the required files are uploaded from the TFTP server into the terminal and then activated following a terminal reboot. System files can be manually uploaded (see ‘Uploading System Files’ on page 226‘). Inventory File Software release 8.2.10 and all future software releases, contains an inventory file (similar to a manifest file) which is used to validate the software files in the terminal. To view the Software Status of the terminal: Select Link, Local or Remote > Summary Software status Function Standard Software Release The software status indicates ‘Standard Software Release’ if the following system software files have not been changed since the last TFTP Upgrade. Kernel image file Software image file Firmware image files Configuration files Modified Software Release The software status indicates ‘Modified Software Release’ if the system software files have been changed since the last TFTP Upgrade. This could be caused by: an image file which has been uploaded to the terminal since the last TFTP upgrade which is not part of that upgrade. an image file which was part of the last TFTP upgrade but was subsequently deleted. Upgrade Prerequisites To minimize disruption of link traffic and prevent your terminals from being rendered inoperative, please follow the procedures described in this section together with any additional information or instructions supplied with the upgrade package. Before upgrading the terminal, ensure that you have saved the configuration file (see ‘Saving the terminal's configuration’ on page 89) as well as the cross connection configuration (see ‘Saving cross connection configurations’ on page 155). The Remote terminal upgrade process will be faster if the bandwidth allocated to the management ethernet capacity is maximized. The terminal software must be identical at both ends of the link. At the end of the terminal upgrade process, the versions of image files (kernel software, and firmware) that were in use before the upgrade are still in the terminal. You can restore them, if required, by editing the image tables and reactivating the old files (see ‘Changing the Status of an Image ’ on page 232). IMPORTANT NOTE: Ensure you are logged into the Near end terminal as Admin before you start an upgrade. Aprisa XE User Manual Maintenance | 215 Software Upgrade Process Unzip and save the following folders to your hard drive: 8.6.77 Software tftpd32.exe The following steps are required for the software upgrade process: 1. Identify the correct TFTP upgrade type (see ‘Identifying the Correct TFTP Upgrade Type’ on page 217). 2. If the terminals are operating software prior to 8.3.40: Upload the Root File System (see ‘Uploading the Root File System’ on page 216) Upload the Motherboard Images (see ‘Uploading the Motherboard Images’ on page 216). Reboot the terminal. 3. Go through the steps of the TFTP upgrade process (see ‘TFTP Upgrade Process’ on page 221). 4. Upgrade for new FXO/FXS and modem images 5. Reboot the terminal. 6. Clear the Java and web browser caches (see ‘Step 7: Clear the Java and web browser caches’ on page 223). If the TFTP upload process fails, an ‘Upload Fail’ alarm is raised. If the TFTP upload process fails due to a power failure, the alarm is raised upon power recovery. Aprisa XE User Manual 216 | Maintenance Uploading the Root File System Note: Uploading of image files can only be performed to the local terminal i.e. not via the link to the remote terminal. 1. Logon to the local terminal as admin. 2. Go to SuperVisor > Local > Maintenance > Upload > Software. 3. Browse to the 8.6.77 Software folder and select ‘C-CC-R-8_6_7.img’. 4. Click Upload and wait for the upload status to display Succeeded. 5. Activate the ‘C-CC-R-8_6_7.img’ with SuperVisor Local > Maintenance > Image Table (see ‘Changing the Status of an Image File’ on page 232). Uploading the Motherboard Images The E1 and E2 motherboard images do not update as part of the TFTP upgrade. Check if the correct motherboard images are loaded with SuperVisor Local > Maintenance > Image Table. Example: Radio on V8.4.60 with a Rev C motherboard. The Motherboard Firmware images for this software version are: Motherboard Type Image Files Required Rev C C-fpga_E1-0-7-0.img C-fpga_E2-0-5-3.img (Motherboard 1 (Motherboard 2) Rev D C-fpga_E1-1-7-3.img C-fpga_E2-1-5-4.img (Motherboard 1 (Motherboard 2) If the motherboard image files are not correct, upload the relevant image files. Note: Uploading of image files can only be performed to the local terminal i.e. not via the link to the remote terminal. 1. Logon to the local terminal as admin 2. Go to SuperVisor > Local > Maintenance > Upload > Firmware. 3. Browse to the 8.6.77 Software folder and select ‘C-fpga_Ex-x-x-x.img’. 4. Click Upload and wait for the upload status to display Succeeded. 5. Activate the ‘C-fpga_Ex-x-x-x.img’ with SuperVisor Local > Maintenance > Image Table (see ‘Changing the Status of an Image File’ on page 232). Aprisa XE User Manual Maintenance | 217 Identifying the Correct TFTP Upgrade Type The correct TFTP upgrade type will depend on both the Bootloader Version and the Software Version Type. Aprisa XE terminals running the older bootloader software (bootloader version 0) have a limitation on the number of software images that can be loaded simultaneously into a terminal. Identifying the Bootloader Version Determine which bootloader version your terminal is running by using the SuperVisor menu item Maintenance > Support Summary and look for the ‘Bootloader Version’ number: (1) If your terminal is running bootloader version 1 or greater, use the TFTP full upgrade process. (2) If your terminal is running bootloader version 0 and running a software version prior to 7.0.6, use the TFTP partial upgrade process. (3) If your terminal is running bootloader version 0 and running a software version 7.0.6 or later, use the TFTP standard upgrade process. (4) HSD terminals cannot run with bootloader version 0. Aprisa XE User Manual 218 | Maintenance Identifying the Software Version Type There are six different software version types; ETSI type 1, ETSI type 1 HSD, ETSI type 2, ETSI type 2 HSD, FCC Part 101 and FCC Part 90. To determine which Software Version Type is currently installed on the terminal, take note of the ‘Software Version’ on SuperVisor Summary page. The last three characters indicate the Software Version Type. ETSI Compliance Body 8_6_77_E0 The E0 variant supports ETSI (Type 1) 1+0 and MHSB terminals with the same variants as Aprisa XE software version 8.4.40. 8_6_77_E1 The E1 variant supports ETSI (Type 2) 1+0 and MHSB terminals with the same variants as Aprisa XE software version 8.4.40 except for the 400 MHz 25 kHz and 50 kHz which has been replaced with 900 MHz 25 kHz and 50 kHz. 8_6_77_E0h The E0h variant supports ETSI (Type 1) Hitless Space Diversity (HSD) terminals with the same variants as Aprisa XE software version 8.4.40. 8_6_77_E1h The E1 variant supports ETSI (Type 2) Hitless Space Diversity (HSD) terminals with the same variants as Aprisa XE software version 8.4.40 except for the 400 MHz 25 kHz and 50 kHz which has been replaced with 900 MHz 25 kHz and 50 kHz. FCC Compliance Body 8_6_77_F0 The F0 variant supports FCC part 90 1+0 and MHSB terminals. 8_6_77_F0h The F0h variant supports FCC part 90 Hitless Space Diversity (HSD) terminals. 8_6_77_F1 The F1 variant supports FCC part 101 1+0 and MHSB terminals. 8_6_77_F1h The F1h variant supports FCC part 101 Hitless Space Diversity (HSD) terminals. Aprisa XE User Manual Maintenance | 219 Upgrade Version Files The following table defines the purpose of the upgrade version files: Upgrade Version File Upgrade Type Software Version Type 8_6_77_E0a Full TFTP upgrade ETSI TYPE 1 8_6_77_E0 Standard TFTP upgrade ETSI TYPE 1 8_6_77_E0h Standard TFTP upgrade ETSI TYPE 1 HSD 8_6_77_E0p Partial TFTP upgrade ETSI TYPE 1 8_6_77_E1a Full TFTP upgrade ETSI TYPE 2 8_6_77_E1 Standard TFTP upgrade ETSI TYPE 2 8_6_77_E1h Standard TFTP upgrade ETSI TYPE 2 HSD 8_6_77_E1p Partial TFTP upgrade ETSI TYPE 2 8_6_77_F0a Full TFTP upgrade FCC Part 90 8_6_77_F0 Standard TFTP upgrade FCC Part 90 8_6_77_F1a Full TFTP upgrade FCC Part 101 8_6_77_F1 Standard TFTP upgrade FCC Part 101 Installing RF Synthesizer Configuration Files If you are upgrading from a software version prior to 7_1_x, you will need to install new RF synthesizer files, refer to ‘Configuration Files’ on page 226. You can then upgrade the terminal using TFTP (see page 221). Frequency Band Synthesizer File(to be installed) Comments 300, 400 MHz XE_300_400_type_1_synth.cfg BB synthesizer 300, 400 MHz XE_300_400_type_2_synth.cfg E3 synthesizer 300, 400 MHz XE_300_400_type_3_synth.cfg 5 kHz sythesizer step 600, 700, 800, 900 MHz XE_600_700_800_900_synth.cfg 1400 MHz XE_1400_synth.cfg 1400 MHz XE_1400TCVR_synth.cfg 1800 MHz XE_1800_synth.cfg 2000, 2500 MHz XE_2000_2500_synth.cfg Aprisa XE User Manual New transceiver (introduced April 2012) 220 | Maintenance TFTP Upgrade Process Types TFTP partial upgrade process Run the TFTP upgrade process by typing 8_6_77_E0p in the Upgrade Version field. This will perform a partial upgrade which will delete unnecessary image files that might be taking up space in the Image Table (which could prevent a standard upgrade succeeding). Reboot the terminal. Run a TFTP standard upgrade process on the terminal. Reboot the terminal again. TFTP standard upgrade process This TFTP standard upgrade process excludes FPGA images for the newly introduced revisions of the Modem, DFXO and DFXS cards. Run the TFTP upgrade process by typing ‘8_6_77_E0’ in the Upgrade Version field. If the standard upgrade fails, it may be necessary to make space for the new images by manually deleting ‘Inactive’ firmware image files. To delete a firmware image file, select the SuperVisor menu item Maintenance > Image Table, select the firmware image and click on Edit. Set the IMAGE DETAILS Command to ‘Delete’ and click ‘Apply’. Reboot the terminal. Additional TFTP upgrade options have been provided to load the new images separately. Run the TFTP upgrade process using the file: ‘F1_8_6_7’ to load images for the newest DFXO and DFXS cards (rev D). ‘F2_8_6_7’ to load images for all revisions of DFXO and DFXS cards. ‘F3_8_6_7’ to load images for the newest Modem card (rev D). Reboot the terminal again. TFTP full upgrade process Run the TFTP upgrade process for 1+0 and MHSB terminals by typing ‘8_6_77_E0a’ in the Upgrade Version field. Run the TFTP upgrade process for HSD terminals by typing ‘8_6_77_E0h’ in the Upgrade Version field. Reboot the terminal. Aprisa XE User Manual Maintenance | 221 TFTP Upgrade Process To upgrade a terminal using the TFTP: 1. Run the TFTP server. 2. Login to the Near end terminal / local terminal (see ‘IP Addressing of Terminals’ on page 53). 3. Run the TFTP upgrade process on the Remote terminal. 4. Reboot the Remote terminal. 5. Run the TFTP upgrade process on the Local terminal. 6. Reboot the Local terminal. 7. Clear the Java and web browser caches. Step 1: Run the TFTP server 1. Double-click tftpd32.exe (located in the TFTPD directory) from the Aprisa CD supplied with the product. Leave the TFTPD32 application running until the end of the upgrade process. 2. Click Settings and make sure that both SNTP server and DHCP server are not selected (no tick), and click OK. 3. Click Browse and navigate to the root directory on the Aprisa CD (for example, D:\) supplied with the product, then click OK. 4. Note down the IP address of the TFTP server (shown in the Server Interfaces drop-down list in the TFTPD32 window) as you will need it later. Aprisa XE User Manual 222 | Maintenance Step 2: Log into the Local terminal Use SuperVisor to log into the Near end terminal (now the Local terminal) (see ‘IP Addressing of Terminals’ on page 53) with either 'modify' or 'admin' privileges. Step 3: Run the TFTP upgrade process on the Remote terminal 1. Select Remote > Maintenance > Upload > TFTP Upgrade. 2. Enter the IP address of the TFTP server. 3. Enter the version number of the software that you are upgrading to as a three digit number separated by underscores, for example, 8_6_77_E0 for ETSI variants. 4. Click Apply and check the TFTP server for download activity. The Upgrade Result changes from 'Executing' to either 'Succeeded' or 'Failed'. Note: This may take several minutes when upgrading the remote terminal. If the upgrade has failed: The TFTP server IP address may be set incorrectly The 'Current Directory' on the TFTP server was not pointing to the location of the upload config file e.g. 'Rel_8_6_77_E0.cfg' . There may not be enough free space in the image table to write the file. Inactive images can be deleted (and the terminal rebooted) to free up space for the new image (see ‘Changing the Status of an Image File’ on page 232). Step 4: Reboot the Remote terminal Reboot the remote terminal before proceeding with the next step of the upgrade process (see ‘Rebooting the Terminal’ on page 233). 1. Select Remote > Maintenance > Reboot and select [Hard Reboot] Communications to SuperVisor remote page will fail until the remote terminal reboot has completed. Aprisa XE User Manual Maintenance | 223 Step 5: Run the TFTP upgrade process on the Local terminal. 1. Select Local > Maintenance > Upload > TFTP Upgrade. 2. Enter the IP address of the TFTP server (that you noted earlier) 3. Enter the version number of the software (that you are upgrading to) for example, 8_6_77_E0. 4. Click Apply and check the TFTP server for download activity. The Upgrade Result changes from 'Executing' to either 'Succeeded' or 'Failed'. Note: This may take several minutes when upgrading the remote terminal. Step 6: Reboot the Local terminal Reboot the local terminal before proceeding with the next step of the upgrade process (see ‘Rebooting the Terminal’ on page 233). 1. Select Local > Maintenance > Reboot and select [Hard Reboot] 2. Log back into the Local terminal when the reboot has completed. Step 7: Clear the Java and web browser caches After upgrading the terminal you should clear the Java and web browser caches. The files stored in them may cause the SuperVisor and Cross Connections applications to display incorrectly. To clear the Java cache (Windows XP, Java 1.6): 1. Select Start > Control Panel. 2. Select Java 3. Click the General tab. 4. In the ‘Temporary Internet Files’, click Settings 5. Click on ‘Delete Files’ (‘Applications and Applets’ and ‘Trace and Log Files’ both ticked) and OK to confirm. Aprisa XE User Manual 224 | Maintenance To clear your web browser cache (Mozilla Firefox 1.x and above): 1. Select Tools > Options. 2. Select Privacy and then click Cache. 3. Click Clear to clear the cache, and then click OK to confirm. Aprisa XE User Manual Maintenance | 225 To clear your web browser cache (Internet Explorer 7.0 and above): 1. Select Tools > Internet Options. 2. On the General tab 3. In Browsing history, click Delete 4. In the ‘Temporary Internet Files’, click Delete Files and Yes to confirm. Aprisa XE User Manual 226 | Maintenance Uploading System Files System files e.g. configuration files, kernel image files, software image files and firmware image files can be uploaded manually. Note: You should only upgrade components that need changing. It is not always necessary, for instance, to replace kernel or software files when upgrading a single firmware file. If interdependency exists between file types, this will be made clear in the documentation that accompanied the update package. Configuration Files Configuration files (.cfg) are compressed archives containing a script to instruct the terminal on how to handle the other files in the archive. Uploading of configuration files can only be performed to the Local Terminal (not via the link to the Remote Terminal). RF synthesizer configuration files The RF synthesizer configuration archive contains files that provide values for the transmitter and receiver synthesizers to operate across the supported frequency bands. Synthesizer configuration filenames have the following format: XE_(frequency bands)_synth.cfg e.g. XE_300_400_synth.cfg Modem configuration files The Modem configuration archive contains files that provide values for the Modem to operate at the various supported channel sizes and modulation types. Modem configuration filenames have the following format: modem_(version number).cfg e.g. modem_8_3_1.cfg (ETSI variants) Cross-connect configuration files The Cross-connect configuration archive contains the Cross Connections application program that can be launched from within SuperVisor. Cross-connect configuration filenames have the following format: C-crossconnect_(version number).cfg e.g. C-crossconnect_8_6_7.cfg Aprisa XE User Manual Maintenance | 227 To upload a configuration file: 1. Select Local > Maintenance > Config Files > Upload Configuration 2. Browse to the location of the file required to be uploaded into the terminal *.cfg. 3. Click on Upload. The normal response is Succeeded if the file has been loaded correctly. A response of ‘Failed’ could be caused by: Not enough temporary space in the filesystem to uncompress the archive and execute the script A file or directory expected by the script not being present on the filesystem 4. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233). Aprisa XE User Manual 228 | Maintenance Image Files Image files (.img) are loaded into the terminal and either contains code that is executed by the system processor, or contain instructions to configure the various programmable logic elements. The image file types that can be uploaded are: Kernel image files Software image files Firmware image files Note: The Bootloader image file C-CC-B-(version number).srec and Flash File System image file C-CC-F(version number).img can only be changed in the factory. Uploading of image files can only be performed to the local terminal (not via the link to the remote terminal). To upload and activate an image file: 1. Upload the required image file. If the Upload Status page show ‘executing’, then ‘writing to flash’, then ‘Succeeded’, then the file has been written into the image table correctly. If the Upload Status is ‘Failed’, there may not be enough free space in the image table to write the file. Inactive images can be deleted (and the terminal rebooted) to free up space for the new image (see ‘Changing the Status of an Image File’ on page 232). 2. Set the status of the image to ‘activate’ (see ‘Changing the Status of an Image ’ on page 232). This actually sets the status to ‘Selected’ until after a terminal reboot. 3. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233). This activates the selected image. The image table status will now show ‘Active’. The previous image file status will now show as ‘Inactive’. Aprisa XE User Manual Maintenance | 229 Kernel image files Kernel image files contain code that forms the basis of the microprocessor’s operating system. There can only ever be two kernel image files in the image table, the active and the inactive. Kernel filenames have the following format: C-CC-K-(version number).img e.g. C-CC-K-6_0_0.img To upload a kernel image file; 1. Select Local > Maintenance > Upload > Kernel 2. Browse to the location of the file required to be uploaded into the terminal *.img. 3. Click on Upload. 4. Activate the image (see ‘Changing the Status of an Image File’ on page 232). 5. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233). Software image files Software image files contain code that forms the basis of the terminal’s application and management software (including the Web-based GUI). There can only ever be two software image files in the image table, the active and the inactive. Software image filenames have the following format: C-CC-R-(version number).img e.g. C-CC-R-8_6_7.img To upload a software image file; 1. Select Local > Maintenance > Upload > Software 2. Browse to the location of the file required to be uploaded into the terminal *.img. 3. Click on Upload. Software image files may take one or two minutes to upload as they can be quite large (≈ 2 Mbytes). The size of this file has caused some Microsoft Internet Explorer proxy server setups to abort during the software update process. To avoid this problem, either set the proxy file size limit to 'unlimited' or avoid the use of the proxy altogether. 4. Activate the image (see ‘Changing the Status of an Image File’ on page 232). 5. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233). Aprisa XE User Manual 230 | Maintenance Firmware image files Firmware image files contain instructions to configure the various programmable logic elements in the terminal. There can only ever be two firmware image files for the same HSC version in the image table, the active and the inactive. Firmware image filenames have the following format: C-fpga_ff-x-y-z.img e.g. C-fpga_E5-0-7-3.img where ff indicates the function (motherboard, interface card, etc). Function Number Function E1 Motherboard 1 E2 Motherboard 2 E5 QJET Interface Card E7 Q4EM Interface Card E8 DFXO Interface Card E9 DFXS Interface Card EA Modem EB QV24 Interface Card EC HSS Interface Card ED PSC (component of HSD system) EE PIC (component of HSD system) FA HSD modem FB QV24 Sync Interface Card where x indicates the HSC (hardware software compatibility) version. where y indicates the firmware major revision number where z indicates the firmware minor revision number To upload a firmware image file; 1. Select Local > Maintenance > Upload > Firmware 2. Browse to the location of the file required to be uploaded into the terminal *.img. 3. Click on Upload. 4. Activate the image (see ‘Changing the Status of an Image File’ on page 232). 5. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233). Aprisa XE User Manual Maintenance | 231 Viewing the Image Table To view the image table: 1. Select Link or Local or Remote > Maintenance > Image Table. The image table shows the following information: Heading Function Index A reference number for the image file Type The image type ‘Kernel’, ‘Software’ or ‘Firmware’. Status The status of the image; 'Active', 'Inactive', ‘Selected’, ‘Current (deselected)’ Image Size The image file size in bytes Version The image file name and version details Note: Configuration file details do not appear in the image table. Aprisa XE User Manual 232 | Maintenance Changing the Status of an Image File To change the status of an image: 1. Select Link or Local or Remote > Maintenance > Image Table. 2. Select the image you wish to change and click Edit. 3. On the Image Details, select the status from the Command drop-down list and click Apply. Status Function Active The image is currently being used by the system. Inactive The image is not currently being used by the system and could be deleted. Selected The image is not currently being used by the system but has been activated and will become active following a terminal reboot. Current (deselected) The image is currently being used by the system but as another image has been selected, it will become inactive following a terminal reboot. Aprisa XE User Manual Maintenance | 233 Rebooting the Terminal The local or remote terminals can be rebooted by SuperVisor. You can specify a ‘Soft Reboot’ which reboots the terminal without affecting traffic or a ‘Hard Reboot’ which reboots the terminal (similar to power cycling the terminal). You can specify an immediate reboot or setup a reboot to occur at a predetermined time. To reboot the terminal: 1. Select Link or Local or Remote > Maintenance > Reboot. 2. Select the Reboot Type field: Reboot Type Function None Does nothing. Soft Reboot Reboots the software but does not affect customer traffic. Hard Reboot Reboots the entire terminal and affects customer traffic. This reboot is similar cycling the power off and on. 3. Select the Reboot Command field: Reboot Command Function None Does nothing Reboot Now Execute the selected reboot now Timed Reboot Set the Reboot Time field to execute the selected reboot at a later date and time. This feature can be used to schedule the resulting traffic outage for a time that has least customer impact. Cancel Reboot Cancel a timed reboot. 4. Click Apply to execute the reboot or Reset to restore the previous configuration. Aprisa XE User Manual 234 | Maintenance Support Summary The support summary page lists key information about the terminal, for example, serial numbers, software version, frequencies and so on. To view the support summary: Select Link or Local or Remote > Maintenance > Support Summary. Aprisa XE User Manual Maintenance | 235 Installing Interface Cards CAUTION: You must power down the terminal before removing or installing interface cards. Interface cards are initially installed in the factory to the customers’ requirements however, during the life of the product, additional interface cards may need to be installed. Unless the terminals are protected (see ‘Protected terminals’ on page 197), installing new interface cards involves a substantial interruption of traffic across the link. Staff performing this task must have the appropriate level of education and experience; it should not be attempted by inexperienced personnel. To install an interface card: 1. Switch off the power to the terminal. 2. Prepare the terminal for new interface cards (see ‘Preparing the Terminal for New Interface Cards’ on page 236). 3. Install the interface card (see ‘Installing an Interface Card’ on page 238). 4. Power up the terminal. 5. Configure the slot (see ‘Configuring a Slot’ on page 240). A slot can be configured before installing a new interface card, or after the interface card is installed and the terminal power cycled. 6. Configure the cross connections. (see ‘Configuring the traffic cross connections’ on page 158) Aprisa XE User Manual 236 | Maintenance Preparing the Terminal for New Interface Cards To prepare the terminal for a new interface card: 1. Remove the terminal from service by first switching off the terminal power. For an AC powered terminal, remove the AC power connector. For a DC powered terminal, switch off the DC circuit breaker or supply fuse. 2. Remove all other cables from the terminal, marking their locations first, if necessary, to aid later restoration. The safety earth connection must be the last cable removed. 3. Ensure you have unobstructed access to the top and front of the terminal. Remove the terminal from the equipment rack, if required. 4. Remove the top cover of the terminal by removing two socket screws from the rear. Note: The top cover slides back towards the rear of the chassis. 5. Remove the front fascia by removing the four front panel socket screws. Note: The front fascia first hinges out to clear the antenna connector and earth stud, and is then removed by unclipping from the chassis and sliding downwards. See illustration below. Aprisa XE User Manual Maintenance | 237 6. Remove the card securing screw from the required interface slot. 7. There are two types of interface slot blanking plates, the seven tab break off and the single slot type (newer type). If the blanking plate is the seven tab break off, remove the slot blanking tab by folding the tab to and fro until it breaks off. If the blanking plate is the single slot type, unclip the blanking plate from behind the slot (assuming that the card securing screw has already been removed). Aprisa XE User Manual 238 | Maintenance Installing an Interface Card To install an interface card: 1. Remove the interface card from its packaging and static-safe bag. CAUTION: To avoid static damage to the terminal or the interface card being installed, use a static discharge wristband or similar antistatic device. 2. Offer the interface card into the chassis at an angle until the front panel of the card engages in the chassis. 3. Rotate the card in the chassis until it is level, and both parts of the card interface bus connector engage with the socket. Push down evenly on the interface card to seat it into the socket. Aprisa XE User Manual Maintenance | 239 4. Replace the card securing screw. Note: Some interface cards may not have the bracket to accept the card securing screw. 5. Replace the fascia and top covers, restore all cables, and power up the terminal. Aprisa XE User Manual 240 | Maintenance Configuring a Slot 1. Select Link or Local or Remote > Interface > Slot Summary. 2. Select the required slot and click Configure Slot. 'Slot' shows the slot the interface card is plugged into in the terminal (A – H). Details of the interface card currently installed in the slot are: 'HSC’ (hardware software compatibility) A number used by the system software to determine which FPGA ‘firmware image file’ to use in the interface card installed. 'H/W Rev’ (hardware revision). ‘Installed’ field shows the actual interface card installed in the slot. If there is no interface card installed in the slot, this field will show ‘none’. ‘Expected’ shows interface card type that had been previously installed. Interface cards can be setup before they are installed in the terminal or after they are installed in the terminal. 3. To setup a new interface card in a slot, select the interface card type you want to fit (or has been fitted) from the ‘Expected’ drop-down menu. Note: The transmitter, receiver and modem are configured in other sections (see ‘Configuring the terminal’ on page 69). 4. Click Apply to apply changes or Reset to restore the previous configuration. Aprisa XE User Manual Troubleshooting | 241 14. Troubleshooting Loopbacks Loopbacks are used as a tool for testing or as part of the commissioning process and will affect customer traffic across the link. The terminal supports three types of loopbacks: RF radio loopback Interface loopbacks, set at the interface ports Timeslot loopbacks RF Radio Loopback The RF radio loopback provides a loopback connection between the radio TX and radio RX. Each terminal is looped back independently. All traffic entering the transmit stage of the transceiver is transmitted on the RF link but is also looped back to the receiver section of the transceiver. This loopback will affect all traffic through the terminal. When the RF loopback is activated, both the radio RX and TX LEDs will flash. An RF loopback will automatically deactivate after the period set (in seconds) in the RF Loopback Timeout field. The default entry is 3600 seconds (60 minutes). When an RF loopback is activated, the ethernet path is disabled to prevent ethernet loopbacks. An RF loopback is deactivated if the terminal is rebooted. To activate or deactivate the RF loopback: Select Link or Local or Remote > Maintenance > Loopbacks. To activate the RF loopback, tick the RF Loopback checkbox. Untick the checkbox to deactivate it. Click Apply to apply changes or Reset to restore the previous configuration. Aprisa XE User Manual 242 | Troubleshooting Interface Loopbacks The interface loopback provides a loopback connection for the customer-connected equipment. These loopbacks are applied on a port-by-port basis and can only be enabled on active ports i.e. the port has to be activated by assigning traffic to it by the Cross Connections application. These are two types of interface loopbacks: Line Facing – port traffic from the customer is transmitted over the RF link but is also looped back to the customer Radio Facing – traffic received from the RF link is passed to the customer port but is also looped back to be transmitted over the RF link. Loopback type Description QJET (whole tributary) The QJET interface port has both Line Facing and Radio Facing loopbacks (see ‘QJET Port Settings’ on page 102). The interface card green LED flashes while the loopback is active. QJET (individual timeslot) The Cross Connections application can loopback framed E1 / T1 timeslots (see ‘Timeslot Loopbacks’ on page 243). Q4EM port The Q4EM interface port has both Line Facing and Radio Facing loopbacks (see ‘Q4EM Port Settings’ on page 104). The interface card yellow LED flashes while the loopback is active. DFXO port The DFXO interface Line Facing loopback loops back the port data to the customer. This loopback is performed on the digital path of the codec. The interface card yellow LED flashes while the loopback is active. DFXS port The DFXS interface Line Facing loopback loops back the port data to the customer. This loopback is performed on the digital path of the codec. The interface card yellow LED flashes while the loopback is active. HSS port The HSS interface Line Facing loopback loops back the port data to the customer. The interface card top green LED flashes while the loopback is active. QV24 port The QV24 interface Line Facing loopback will loop back the port data to the customer. Ethernet No loopback possible. Aprisa XE User Manual Troubleshooting | 243 Timeslot Loopbacks You can loopback framed E1 / T1 timeslots in the Cross Connections application. 1. Open the Cross Connections application. 2. Right-click the timeslot you want to loop back. 3. Select Timeslot Loopback - the looped timeslot will display in black: Aprisa XE User Manual 244 | Troubleshooting Alarms The LEDs (OK, RX, and TX) on the front panel illuminate either amber or red when there is a fault condition: Amber indicates a minor alarm that should not affect traffic across the link. Red indicates a major alarm condition that could affect traffic across the link. A major or minor alarm can be mapped to the external alarm outputs (see ‘Configuring the External Alarm Outputs’ on page 83). Diagnosing Alarms To view the Alarm Summary and their current states: Select Link or Local or Remote > Alarms > Summary. Aprisa XE User Manual Troubleshooting | 245 Alarm Explanation Synthesizer Status The selected transmit frequency is outside the tuning range of the transmitter synthesizer Modem Lock The terminal modem is not synchronized with the modem at the other end of the link TX Temp Shutdown The transmitter power amplifier temperature is greater than 75°C. The transmitter has shut down to prevent damage. TX Temp Warning The transmitter power amplifier temperature is greater than 70°C. The transmitter will continue to operate in this condition, but if the power amplifier temperature increases above 75°C, a major alarm condition is set and the transmitter will shut down to prevent further damage. TX AGC Voltage The transmitter power amplifier automatic gain control is out of limits for normal operation TX Reverse Power There is excessive reflected power at the transmitter port of the terminal, indicating a low return loss in the path between transmitter port and the antenna. TX Return Loss Status Indicates the difference between the transmitted power and the amount of power being reflected back into the terminal. The alarm will trigger when there is too much reflected power from the antenna that will degrade link performance. RX RSSI The RX RSSI alarm threshold is determined by the RSSI Thresholds for each of the modulation types (see ‘Setting the RSSI Alarm Threshold’ on page 80) Fan 1 The internal cooling fan 1 is not operating Fan 2 The internal cooling fan 2 is not operating External Input 1 -2 Indicates an active alarm state on the the external alarm input Alarm Output 1 - 4 Indicates an active alarm state on the the external alarm output MHSB Switch Indicates that the MHSB has switched over. The MHSB alarm is only shown if MHSB mode is enabled (see ‘Configuring the Terminals for MHSB’ on page 188). To view detailed alarm information: Select Link or Local or Remote > Alarms > Alarm Table The Alarm Table shows the source of the alarm and the type, the slot (and port, if applicable) where the alarm originated, the severity and the date and time the alarm occurred. To further diagnose the cause of the alarm (see ‘Identifying Causes of Alarms’ on page 250, and ‘Alarm Types’ on page 275). Aprisa XE User Manual 246 | Troubleshooting Viewing the Alarm History The alarm history page shows the historical alarm activity for up to 50 alarms. This page refreshes every 30 seconds. The alarm history for up to 100 alarms can be seen using SNMP (see ‘Configuring SNMP’ on page 85). To view the alarm history: Select Link or Local or Remote > Alarms > Alarm History. Field Explanation Source The component within the terminal that generated the alarm Type The type of alarm (see ‘Alarm types and sources’ on page 275) Slot The slot where the alarm originated, if applicable Port The port where the alarm originated, if applicable Severity Whether the alarm was a major or minor alarm Status Whether the alarm is active or cleared Time The date and time when the alarm occurred To clear the alarm history: Select Local or Remote > Alarms > Clear History This function clears all the alarm history including the 600 alarm rolling buffer (see ‘Saving the Alarm History’ on page 247). Aprisa XE User Manual Troubleshooting | 247 Saving the Alarm History The last 1500 alarms are stored in a rolling buffer which can be saved as a *.csv file. To save the alarm history: Select Local > Alarms > Save History A File Download dialog box opens. Click on Save to save the *.csv file to a folder or click on Open to open the file in the SuperVisor page. Example of file: Source Type Slot Port Severity Status Time Modem Modem Modem QV24 QV24 QV24 System Modem Modem Modem Transmitter Transmitter System QV24 QV24 QV24 HSS HSS QJET mdLOS mdTdmAlignmentLost mdDemodAlignmentLost v24CtrlLineLoss v24CtrlLineLoss v24CtrlLineLoss mdClkSyncFail mdLOS mdTdmAlignmentLost mdDemodAlignmentLost txADCChZeroLo txADCChZeroLo mdClkSyncFail v24CtrlLineLoss v24CtrlLineLoss v24CtrlLineLoss hssLoss hssLoss LOS Aux Aux Aux ---Aux Aux Aux Transmitter Transmitter ---G Major Major Major Major Major Major Major Major Major Major Minor Minor Major Major Major Major Minor Minor Minor Active Active Active Active Active Active Active Cleared Cleared Cleared Active Cleared Cleared Cleared Cleared Cleared Active Cleared Active Tue Jan 22 12:45:54 2008 Tue Jan 22 12:45:54 2008 Tue Jan 22 12:45:54 2008 Tue Jan 22 12:45:55 2008 Tue Jan 22 12:45:55 2008 Tue Jan 22 12:45:55 2008 Tue Jan 22 12:45:57 2008 Tue Jan 22 12:45:57 2008 Tue Jan 22 12:45:57 2008 Tue Jan 22 12:45:57 2008 Tue Jan 22 12:45:57 2008 Tue Jan 22 12:45:58 2008 Tue Jan 22 12:45:58 2008 Tue Jan 22 12:45:59 2008 Tue Jan 22 12:45:59 2008 Tue Jan 22 12:45:59 2008 Tue Jan 22 13:51:17 2008 Tue Jan 22 13:51:17 2008 Tue Jan 22 13:51:35 2008 SNR (dB) 35.28 35.29 35.26 35.28 35.27 35.29 RSSI (dBm) -52.8 -52.8 -52.8 Note: Windows security settings can prevent the download of files. In this case, click on the windows security message and select the SuperVisor menu option again (Alarms > Save History). To save the alarm history from the Remote terminal, login to the Remote terminal and Select Local > Alarms > Save History. Aprisa XE User Manual 248 | Troubleshooting Viewing Interface Alarms To view the alarms for a particular interface: 1. Select Link or Local or Remote > Interface > Interface Summary. 2. Select the desired interface card slot from the Interface Summary and click Alarms. This opens a page as shown below with a summary of the alarms on the interface card: The following fields are displayed: Source: The type of interface card that generated the alarm Type: The type of interface alarm Slot: The slot of the interface card that generated the interface alarm Port: The port that generated the interface alarm Severity: Whether the interface alarm was major or minor 3. Return to the Interface Summary page by either selecting Options > Interface Summary or clicking Back in the browser window. Aprisa XE User Manual Troubleshooting | 249 Clearing Alarms Select Link or Local or Remote > Alarms > Clear Alarms MHSB Command If a MHSB switchover event occurs, the OK LED on the front panel changes to amber. To clear the MHSB switchover alarm: Select ‘Clear Switched Alarm’ from the MHSB Command drop-down list and click on Apply. Image Table Alarm An image table alarm occurs if a problem occurred during the boot process which may have left the image table in an inconsistent state. To clear the image table alarm: The default image table alarm: this indicates that the image table has been rebuilt from defaults. This can indicate that an incorrect build of software is running on the terminal. Select ‘Clear the Default Image Table used alarm’ from the Image Table drop-down list and click on Apply. In addition to clearing the image table alarm, you should verify that the active images in the image table are correct for the software release. Upload Alarm An Upload Alarm occurs if the TFTP Upgrade process fails. This can indicate that the upgrade process cannot find the TFTP server or cannot find the software version number entered. To clear the upload alarm alarm: Select ‘Clear the Upload Failure Alarm’ from the Upload Alarm drop-down list and click on Apply. Aprisa XE User Manual 250 | Troubleshooting Identifying Causes of Alarms The following are possible causes of an alarm. LED Colour Possible causes OK Amber A minor system alarm is set Red A major system alarm is set Amber Low RSSI or AGC limits have been exceeded Red Receiver power supply or synthesizer failure Amber AGC, transmitter temperature, forward power or reverse power limits have been exceeded Red Transmit power supply or synthesizer failure RX TX OK LED Colour Alarm condition Suggested action Amber Fan failure Check that the fans are not blocked and can spin freely. Amber Interface card mismatch Using SuperVisor, check that the expected interface card and the fitted interface card are the same. Red Modem lock A modem lock alarm is generally seen when other conditions such as low RSSI are present. If there are no other alarms indicated, check the following: The terminal clocking is set up correctly. Both terminals are using the same modulation. Both terminals are using the same version of software. External RF Interference from equipment operating in adjacent channels. Check the constellation pattern for evidence of disturbances in the RF path. Compare RSSI with the expected values from the original path engineering calculation. Investigate any large differences. If the fault persists, contact your local representative. Red Interface alarms Check that the E1 or Ethernet interface cables are fitted correctly and the equipment they are connected to is functioning correctly. Aprisa XE User Manual Troubleshooting | 251 RX LED Colour Alarm condition Suggested action Amber Low RSSI Check that all antenna and feeder cables are firmly connected and not damaged or kinked Check there is no damage to the antenna Check the TX power and alarm status of the remote terminal Amber Receiver AGC Contact your local 4RF representative Red Receiver power supply Contact your local 4RF representative Colour Alarm condition Suggested action Amber Reverse power Check that all antenna and feeder cables are firmly connected and not damaged or kinked Check there is no damage to the antenna Check that the Receiver and Transmitter ports are correctly connected to the High and Low ports of the duplexer Red Transmitter temperature Check operation of cooling fan or fans Ensure the air grills on the sides of the terminal are clear Ensure the ambient air temperature around the equipment is less than 50˚C TX LED Aprisa XE User Manual 252 | Troubleshooting E1 / T1 Alarm Conditions The QJET interface yellow LED indicates: Loss of signal (LOS) A loss of signal alarm occurs when there is no valid G.703 signal at the E1 / T1 interface RX input from the downstream system. This alarm masks the LOF and AIS received alarms. Loss Of Frame alignment (LOF) A loss of frame alignment alarm occurs when the E1 / T1 interface RX input receives a valid G.703 signal (code and frequency) but does not receive a valid G.704 signal i.e. no frame alignment word, from the downstream system (in framed E1 / T1 modes only) (red alarm in framed T1 modes). This alarm masks the AIS received alarm. Alarm Indication Signal (AIS) An AIS received alarm occurs when AIS is received from the downstream system. An E1 / T1 interface will output AIS to the downstream system if the normal upstream traffic signal is not available e.g. loss of modem synchronization, loss of RF signal across the link (blue alarm in framed T1 modes). Remote Alarm Indicator (RAI) A remote alarm indicator occurs when RAI is received from the downstream system when it has an active LOS or LOF alarm (TS0 NFAS bit 3 in framed E1 modes and yellow alarm in framed T1 modes). TS16 Loss of signal (TS16LOS) A TS16 loss of signal alarm occurs when there is no valid TS16 signal at the E1 interface RX input from the downstream system (in E1 PCM 30 modes only). TS16 Remote Multi-frame Alarm Indicator (RMAI) A remote multiframe alarm indicator occurs when RMAI is received from the downstream system when it has an active TS16LOS alarm (TS16 F0 bit 6 in E1 PCM 30 modes only). TS16 Alarm Indication Signal (TS16AIS) A TS16 Alarm Indication Signal alarm occurs when AIS is received from the downstream system in TS16. An E1 interface will output the TS16 AIS signal to the downstream system if the normal TS16 multiframe signal is not available (in E1 PCM 30 modes only). The QJET interface green LED indicates: The QJET interface green LED flashes when the E1 / T1 port loopback is active. Aprisa XE User Manual Troubleshooting | 253 System Log SuperVisor automatically keeps a log, known as 'syslog', which captures all alarms, errors and events for each terminal. You can specify that the ‘syslog’ is saved to a particular file (see ‘Setting up for Remote Logging’ on page 255). You can then email this file to customer service, if requested, to enable them to fault-find more accurately. Checking the Syslog To view the Syslog: 1. Select Local > Performance > Logging > Syslog. This opens a new window: Aprisa XE User Manual 254 | Troubleshooting 2. The system log is quite hard to decipher in Internet Explorer. If you're using Internet Explorer, select View > Source, which opens the file in a more legible layout in Notepad. Save or print this file, as required. 3. If you want to save the system log, you can save it from within Notepad (or Internet Explorer). Select File > Save As. Navigate to where you want to save the file. Enter a meaningful filename and select 'Text File' from the Save As Type drop-down list. Click Save. You can specify that this file is automatically saved to a computer (see ‘Setting up for Remote Logging’ on page 255). Aprisa XE User Manual Troubleshooting | 255 Setting up for Remote Logging Note: When setting up to save the system log to a specific computer, be aware that the file is constantly updated and may get quite large quite quickly. To set up a terminal for remote logging: 1. Copy the TFTP server application (tftpd32.exe, which is located in the TFTPD directory) from the terminal product CD into a suitable directory on the PC (for example, C:\Program Files\TFTP Server). 2. Create another directory where you want the system logs to be saved for example; C:\Aprisa XE Syslog 3. Double-click tftpd32.exe. 4. Click Settings and make sure that both ‘Syslog Server’ and ‘Save syslog message’ boxes are ticked. 5. Click Browse and select a directory where you want the Syslog file to be saved (created in step 2). 6. Click OK to close the Settings dialog box. Aprisa XE User Manual 256 | Troubleshooting 7. In SuperVisor, select Link or Link or Local or Remote > Terminal > Advanced. 8. In the Remote Syslog Address field, enter the IP address of the PC on which the Syslog server is running. 9. In the Remote Syslog Port field, enter 514. 10. Reboot the terminal (Link or Local or Remote > Maintenance > Reboot). 11. Open the directory where the system logs are being saved to. You should see a file called syslog.txt. Aprisa XE User Manual Interface Connections | 257 15. Interface Connections RJ-45 Connector Pin Assignments RJ-45 pin numbering Interface Traffic Direction All interface traffic directions and labels used in this manual refer to the direction relative to the terminal. Refer to the diagram below. The traffic direction describes the transmit / receive paths and the direction of handshaking and clocking signals, depending on the interface. Aprisa XE User Manual 258 | Interface Connections QJET Interface Connections Pin number Pin function Direction TIA-568A wire colour Transmit Output Green/white Transmit Output Green Not used Receive Input Blue Receive Input Blue/white Not used Orange Not used Brown/white Not used Brown Orange/white RJ-45 connector LED indicators LED Status Explanation Green On Normal operation Yellow On Loss of signal (LOS) or Alarm Indication Signal (AIS) or Loss Of Frame alignment (LOF) in Framed modes Green Flashing Port in loopback The standard QJET interface is 120 ohm balanced. External Balun transformers can be used to provide a 75 ohm unbalanced interface. Aprisa XE User Manual Interface Connections | 259 Ethernet Interface Connections Pin number Pin function Direction TIA-568A wire colour Transmit Output Green/white Transmit Output Green Receive Input Orange/white Not used Blue Not used Blue/white Receive Not used Brown/white Not used Brown Input Orange RJ-45 connector LED indicators LED Status Explanation Green On Ethernet signal received Green Flashing Indicates data traffic present on the interface Note: Do not connect Power over Ethernet (PoE) connections to the Aprisa XE Ethernet ports as this will damage the port. Aprisa XE User Manual 260 | Interface Connections Q4EM Interface Connections Pin number Pin function Direction TIA-568A wire colour Input Green/white M1 Input Green Receive (Ra/R) Input Orange/white Transmit (Tb/R1) Output Blue Transmit (Ta/T1) Output Blue/white Receive (Rb/T) Input Orange Output Brown/white E1 Output Brown RJ-45 connector LED indicators LED Status Explanation Green Off No external source applied to M wire (no M wire current flowing) Green On External source applied to M wire (M wire current flowing) Green Flashing The interface loopback is active Yellow Off E wire relay contact open (no current in external device) Yellow On E wire relay contact closed (current flowing in external device) Aprisa XE User Manual Interface Connections | 261 E&M Signalling Types The Q4EM E&M signalling leads are optically isolated, bi-directional lines which can be externally referenced to meet any of the EIA-464 connection types I, II,IV or V (as shown below). The M1 lead associated with the M wire detector can be externally referenced to earth or battery as required. The E1 lead associated with the E wire output can be externally referenced to earth or battery as required. Aprisa XE User Manual 262 | Interface Connections Aprisa XE User Manual Interface Connections | 263 DFXS Interface Connections The subscriber interface connects the terminal to the customer's 2 wire telephone via a 2 wire line. Each 2 wire channel has two access points: one connects to a customer; the other is a local test port. CAUTION: If there is a power failure at either terminal, any telephone connected at the DFXS will not operate. Please ensure that a separate telephone that is not dependent on local power is available for use in an emergency. RJ-45 Pin number Pin function Direction TIA-568A wire colour Not used Green/white Not used Green Not used Orange/white Ring Bi-directional Blue Tip Bi-directional Blue/white Not used Orange Not used Brown/white Not used Brown RJ-45 connector LED indicators LED Status Explanation Green Off Interface operational but not in service Green On Normal operation Green Flashing Cadenced ringing on line Yellow Off No interface alarm Yellow On Interface alarm Yellow Flashing The interface loopback is active Both LEDs Flashing Loss of CAS signals Aprisa XE User Manual 264 | Interface Connections DFXO Interface Connections The DFXO interface connects the terminal to the telephone network via a 2 wire line. Each DFXO channel has two access points: one connects to a customer; the other is a local test port. RJ-45 Pin number Pin function Direction TIA-568A wire colour Not used Green/white Not used Green Not used Orange/white Ring Bi-directional Blue Tip Bi-directional Blue/white Not used Orange Not used Brown/white Not used Brown RJ-45 connector LED indicators LED Status Explanation Green Off Interface operational but not in service Green On Normal operation Green Flashing Cadenced ringing on line Yellow Off No interface alarm Yellow On Interface alarm Yellow Flashing The interface loopback is active Both LEDs Flashing Loss of CAS signals Aprisa XE User Manual Interface Connections | 265 HSS Interface Connections The connector on the high-speed synchronous serial interface is a high density LFH-60 (as used on standard Cisco WAN port serial interface cables and equivalents). The interface specification (X.21 / V.35 etc) is automatically changed by simply changing the type of interface cable connected to the HSS. LED indicators LED Status Explanation Top green LED On Normal operation Top green LED Flashing Loopback in place Lower green LED On Normal operation Aprisa XE User Manual 266 | Interface Connections Synchronous cable assemblies RS-449 Serial Cable Assembly for DCE (Part number: Cab Sync 449FC) Pin number Pin function Direction Shield Ground 22 SD+ SD- Input Input 23 ST+ ST- Output Output 24 RD+ RD- Output Output 25 RS+ RS- Input Input 26 RT+ RT- Output Output 27 CS+ CS- Output Output 10 37 LL SC Input 11 29 DM+ DM- Output Output 12 30 TR+ TR- Input Input 13 31 RR+ RR- Output Output 17 35 TT+ TT- Input Input 19 20 SG RC Aprisa XE User Manual Interface Connections | 267 RS-449 Serial Cable Assembly for DTE (Part number: Cab Sync 449MT) Pin number Pin function Direction Shield Ground 22 SD+ SD- Output Output 23 ST+ ST- Input Input 24 RD+ RD- Input Input 25 RS+ RS- Output Output 26 RT+ RT- Input Input 27 CS+ CS- Input Input 10 37 LL SC Output 11 29 DM+ DM- Input Input 12 30 TR+ TR- Output Output 13 31 RR+ RR- Input Input 17 35 TT+ TT- Output Output 19 20 SG RC Aprisa XE User Manual 268 | Interface Connections V.35 Serial Cable Assembly for DCE (Part number: Cab Sync V35FC) Pin number Pin function Direction Frame Ground Circuit Ground RTS Input CTS Output DSR Output RLSD Output DTR Input LT Input SD+ SD- Input Input RD+ RD- Output Output SCTE+ SCTE- Input Input SCR+ SCR- Output Output AA SCT+ SCT- Output Output V.35 Serial Cable Assembly for DTE (Part number: Cab Sync V35MT) Pin number Pin function Frame Ground Circuit Ground RTS Output CTS Input DSR Input RLSD Input DTR Output LT Output SD+ SD- Output Output RD+ RD- Input Input SCTE+ SCTE- Output Output SCR+ SCR- Input Input AA SCT+ SCT- Input Input Aprisa XE User Manual Direction Interface Connections | 269 X.21 Serial Cable Assembly for DCE (Part number: Cab Sync X21FC) Pin number Pin function Direction Shield Ground Transmit+ Transmit- Input Input 10 Control+ Control- Input Input 11 Receive+ Receive- Output Output 12 Indication+ Indication- Output Output 13 Timing+ Timing- Output Output Circuit Ground X.21 Serial Cable Assembly for DTE (Part number: Cab Sync X21MT) Pin number Pin function Direction Shield Ground Transmit+ Transmit- Output Output 10 Control+ Control- Output Output 11 Receive+ Receive- Input Input 12 Indication+ Indication- Input Input 13 Timing+ Timing- Input Input Circuit Ground Aprisa XE User Manual 270 | Interface Connections RS-530 Serial Cable Assembly for DCE (Part number: Cab Sync 530FC) Pin number Pin function Direction 14 BA(A), TXD+ BA(B), TXD- Input Input 16 BB(A), RXD+ BB(B), RXD- Output Output 19 CA(A), RTS+ CA(B), RTS- Input Input 13 CB(A), CTS+ CB(B), CTS- Output Output 22 CC(A), DSR+ CC(B), DSR- Output Output Shield 10 CF(A), DCD+ CF(B), DCD- Output Output 15 12 DB(A), TXC+ DB(B), TXC- Output Output 17 DD(A), RXC+ DD(B), RXC- Output Output 18 LL Circuit Ground Input 20 23 CD(A), DTR+ CD(B), DTR- Input Input 24 11 DA(A), TXCE+ DA(B), TXCE- Input Input 25 TM, not used Output Aprisa XE User Manual Interface Connections | 271 RS-530 Serial Cable Assembly for DTE (Part number: Cab Sync 530MT) Pin number Pin function Direction 14 BA(A), TXD+ BA(B), TXD- Output Output 16 BB(A), RXD+ BB(B), RXD- Input Input 19 CA(A), RTS+ CA(B), RTS- Output Output 13 CB(A), CTS+ CB(B), CTS- Input Input 22 CC(A), DSR+ CC(B), DSR- Input Input Shield 10 CF(A), DCD+ CF(B), DCD- Input Input 15 12 DB(A), TXC+ DB(B), TXC- Input Input 17 DD(A), RXC+ DD(B), RXC- Input Input 18 LL Circuit Ground Output 20 23 CD(A), DTR+ CD(B), DTR- Output Output 24 11 DA(A), TXCE+ DA(B), TXCE- Output Output 25 TM, not used Output Aprisa XE User Manual 272 | Interface Connections Cable WAN Connectors Cisco LFH-60 cable name WAN connector Connector gender Label on WAN end 449FC DB-37 female 'to DTE' 449MT DB-37 male 'to DCE' V35FC M34 female 'to DTE' V35MT M34 male 'to DCE' X21FC DB-15 female 'to DTE' X21MT DB-15 male 'to DCE' 530FC DB-25 female 'to DTE' 530MT DB-25 male 'to DCE' Aprisa XE User Manual Interface Connections | 273 QV24 Interface connections The QV24 is always configured as a DCE: RJ45 Pin number Pin function Direction TIA-568A wire colour RTS Input Green / white DTR Input Green TXD Input Orange / white Ground Blue Ground Blue / white RXD Output Orange DSR Output Brown / white CTS Output Brown RJ-45 connector LED indicators LED Status Explanation Green On / flashing Transmit data Yellow On / flashing Receive data QV24S Interface connections The QV24S is always configured as a DCE: RJ45 Pin number Pin function Direction TIA-568A wire colour RTS Input Green / white XTXC Input Green TXD Input Orange / white Ground Blue Ground Blue / white RXD Output Orange RXC Output Brown / white CTS Output Brown RJ-45 connector LED indicators LED Status Explanation Green On / flashing Transmit data Yellow On / flashing Receive data Aprisa XE User Manual Alarm Types and Sources | 275 16. Alarm Types and Sources Alarm Types Transmitter Alarms Transmitter Alarms for all Frequency Bands Type Explanation tx11VFail The transmitter 11 VDC power supply has failed tx28VFail The transmitter 28 VDC power supply has failed tx5VFail The transmitter 5 VDC power supply has failed txAmplifierBalance One side of the transmitter amplifier has failed txEEFail The transmitter on-board memory has failed txMibFail The transmitter MIB is corrupt in EEPROM txReturnLoss The transmitter return loss is high txSynthLD The transmitter synthesizer frequency is not set txTSensorFail The transmitter temperature sensor has failed Transmitter Alarms for 300, 400, 600, 700, 800, 900, 1400 MHz Frequency Bands txADCChZeroLo The transmitter AGC voltage is low txADCChZeroHi The transmitter AGC voltage is high txADCChOneLo The transmitter Forward Power Monitor reading is low txADCChOneHi The transmitter Forward Power Monitor reading is high txADCChTwoLo The transmitter Reverse Power Monitor reading is low txADCChTwoHi The transmitter Reverse Power Monitor reading is high txADCChThreeHi The transmitter temperature is greater than 75°C and the transmitter has shut down txADCChFourLo The transmitter synthesizer tuning voltage is low txADCChFourHi The transmitter synthesizer tuning voltage is high txADCChFiveLo The transmitter 28 VDC power supply voltage is low txADCChFiveHi The transmitter 28 VDC power supply voltage is high txADCChSixLo The transmitter 11 VDC power supply voltage is low txADCChSixHi The transmitter 11 VDC power supply voltage is high txADCChSevenLo The transmitter digital 5 VDC power supply voltage is low txADCChSevenHi The transmitter digital 5 VDC power supply voltage is high txADCChEightLo The transmitter reference 7 VDC power supply voltage is low txADCChEightHi The transmitter reference 7 VDC power supply voltage is high txADCChNineLo The transmitter VCO voltage is low txADCChNineHi The transmitter VCO voltage is high txADCChElevenHi The transmitter temperature is greater than 70°C. Aprisa XE User Manual 276 | Alarm Types and Sources Transmitter Alarms for 2000, 2500 MHz Frequency Bands txADCChZeroLo The transmitter AGC voltage is low txADCChZeroHi The transmitter AGC voltage is high txADCChOneLo The transmitter Forward Power Monitor reading is low txADCChOneHi The transmitter Forward Power Monitor reading is high txADCChTwoLo The transmitter Reverse Power Monitor reading is low txADCChTwoHi The transmitter Reverse Power Monitor reading is high txADCChThreeHi The transmitter temperature is greater than 75°C and the transmitter has shut down txADCChFourLo The transmitter synthesizer tuning voltage is low txADCChFourHi The transmitter synthesizer tuning voltage is high txADCChFiveLo The transmitter 28 VDC power supply voltage is low txADCChFiveHi The transmitter 28 VDC power supply voltage is high txADCChSixLo The transmitter 9 VDC power supply voltage is low txADCChSixHi The transmitter 9 VDC power supply voltage is high txADCChSevenLo The transmitter digital 5 VDC power supply voltage is low txADCChSevenHi The transmitter digital 5 VDC power supply voltage is high txADCChEightLo The transmitter reference -5 VDC power supply voltage is low txADCChEightHi The transmitter reference -5 VDC power supply voltage is high txADCChNineLo The transmitter VCO voltage is low txADCChNineHi The transmitter VCO voltage is high txADCChElevenHi The transmitter temperature is greater than 70°C. Aprisa XE User Manual Alarm Types and Sources | 277 Receiver Alarms Receiver Alarms for all Frequency Bands Type Explanation rx12VFail The receiver 12 VDC power supply has failed rxEEFail The on-board memory has failed rxMibFail The receiver MIB is corrupt in EEPROM rxOff The receiver is off rxRSSIHi The receiver maximum input level has been exceeded rxRSSILo The RSSI is below the alarm threshold setting (see page 80) rxSynthLD The synthesizer frequency is not set Receiver Alarms for 300, 400, 600, 700, 800, 900 MHz Frequency Bands rxADCChZeroLo The receiver 3.3 VDC power supply voltage is low rxADCChZeroHi The receiver 3.3 VDC power supply voltage is high rxADCChOneLo The receiver synthesizer tuning voltage is low rxADCChOneHi The receiver synthesizer tuning voltage is high rxADCChTwoLo The receiver +12 VDC power supply is low rxADCChTwoHi The receiver +12 VDC power supply is high rxADCChThreeLo The receiver +5 VDC power supply is low rxADCChThreeHi The receiver +5 VDC power supply is high rxADCChFourLo The receiver +12 VDC power supply is low (same alarm as TwoLo) rxADCChFourHi The receiver +12 VDC power supply is high (same alarm as TwoHi) rxADCChFiveLo The receiver VCO voltage is low rxADCChFiveHi The receiver VCO voltage is high rxADCChSevenLo The receiver RSSI is lower than the normal operating lower limit rxADCChSevenHi The receiver RSSI is higher than the normal operating upper limit rxADCChEightLo The receiver temperature is greater than 70°C (below spec) rxADCChEightHi The receiver temperature is less than -10°C (below spec) Aprisa XE User Manual 278 | Alarm Types and Sources Receiver Alarms for 1400 MHz Frequency Band rxADCChZeroLo The receiver 3.3 VDC power supply voltage is low rxADCChZeroHi The receiver 3.3 VDC power supply voltage is high rxADCChOneLo The receiver synthesizer tuning voltage is low rxADCChOneHi The receiver synthesizer tuning voltage is high rxADCChTwoLo The receiver -1.5 VDC power supply is low rxADCChTwoHi The receiver -1.5 VDC power supply is high rxADCChThreeLo The receiver +5 VDC power supply is low rxADCChThreeHi The receiver +5 VDC power supply is high rxADCChFourLo The receiver +9 VDC power supply is low rxADCChFourHi The receiver +9 VDC power supply is high rxADCChFiveLo The receiver VCO voltage is low rxADCChFiveHi The receiver VCO voltage is high rxADCChSevenLo The receiver RSSI is lower than the normal operating lower limit rxADCChSevenHi The receiver RSSI is higher than the normal operating upper limit rxADCChEightLo The receiver temperature is greater than 70°C (below spec) rxADCChEightHi The receiver temperature is less than -10°C (below spec) Aprisa XE User Manual Alarm Types and Sources | 279 Receiver Alarms for 2000, 2500 MHz Frequency Bands rxADCChZeroLo The receiver 3.3 VDC power supply voltage is low rxADCChZeroHi The receiver 3.3 VDC power supply voltage is high rxADCChOneLo The receiver synthesizer tuning voltage is low rxADCChOneHi The receiver synthesizer tuning voltage is high rxADCChTwoLo The receiver +12 VDC power supply is low rxADCChTwoHi The receiver +12 VDC power supply is high rxADCChThreeLo The receiver +5 VDC power supply is low rxADCChThreeHi The receiver +5 VDC power supply is high rxADCChFourLo The receiver +9 VDC power supply is low rxADCChFourHi The receiver +9 VDC power supply is high rxADCChFiveLo The receiver VCO voltage is low rxADCChFiveHi The receiver VCO voltage is high rxADCChSevenLo The receiver RSSI is lower than the normal operating lower limit rxADCChSevenHi The receiver RSSI is higher than the normal operating upper limit rxADCChEightLo The receiver temperature is greater than 70°C (below spec) rxADCChEightHi The receiver temperature is less than -10°C (below spec) Aprisa XE User Manual 280 | Alarm Types and Sources MUX Alarms Type Explanation muxInit A MUX card failed to program muxMibEEFail The MIB EEROM is corrupt muxCharEEFail The character data is corrupt Modem Alarms Type Explanation mdLOS The modem has loss of synchronization with the far end mdDemodAlignmentLost The modem is unable to synchronize to the payload framing mdTdmAlignmentLost The modem is unable to synchronize to the system bus timing mdRefAFail The modem reference clock A has failed mdRefBFail The modem reference clock B has failed mdClkSyncFail The modem is unable to synchronize to the system clock mdEEFail The modem EEPROM is corrupt mdUCEPresent The modem has uncorrectable errors Motherboard Alarms Type Explanation mbFan1Fail Fan 1 failure mbFan2Fail Fan 2 failure mbCardMismatch The expected interface card is different to the card that is fitted mbHwHsc A MUX card has an unsupported HSC number Aprisa XE User Manual Alarm Types and Sources | 281 QJET Alarms Type Explanation e1AIS The E1 interface RX input has received an Alarm Indication Signal from the downstream equipment. e1RAI The E1 interface RX input has received a Remote Alarm Indication alarm (RAI) from the downstream equipment. A remote alarm indicator signal is sent from the downstream equipment when it has an active LOS or LOF alarm. e1LOS The E1 interface Loss Of Signal alarm (LOS) e1CRC4 The E1 interface Cyclic Redundancy Check 4 alarm indicates a loss of or corrupted CRC data. e1LOF The E1 interface Loss Of Frame alignment (LOF) e1RMAI The E1 interface RX input has received an RMAI from the downstream equipment. A TS16 remote alarm indicator signal is sent from the downstream equipment when it has an active TS16 LOS or LOF alarm. e1TS16AIS The E1 interface RX input has received a TS16 Alarm Indication Signal from the downstream equipment. e1TS16LOS The E1 timeslot 16 Loss Of Signal alarm t1AIS The T1 interface RX input has received an Alarm Indication Signal from the downstream equipment (AIS Received alarm) t1RAI The T1 interface RX input has received a Remote Alarm Indication alarm (RAI) from the downstream equipment. t1LOS The T1 interface Loss Of Signal alarm (LOS) t1LOF The T1 interface Loss Of Frame alignment (LOF) DFXO Alarms Type Explanation fxoCodecOvld The DFXO detected a codec receive signal overload fxoBillToneOvld The DFXO detected a billing tone input signal overload (greater than 0.8 Vrms into 200 Ω) fxoUnplug The DFXO detected that the exchange line has been unplugged from interface fxoCurrentOvld The DFXO Loop current overload detected (greater than 100 mA) DFXS Alarms Type Explanation fxsCalibError The phone was off-hook during the DFXS initialization phase (during power up) fxsDCDCError The DFXS DC-DC converter has a low battery voltage error fxsCasLock The DFXS has a loss of CAS lock Aprisa XE User Manual 282 | Alarm Types and Sources HSS Alarms Type Explanation hssLoss The HSS has a loss of control pattern hssRxFifoFull The HSS RX FIFO has an overrun hssRxFifoEmpty The HSS RX FIFO has an underrun hssTxFifoFull The HSS TX FIFO has an overrun hssTxFifoEmpty The HSS TX FIFO has an underrun hssRxClockInvalid The HSS RX clock is invalid hssTxClockInvalid The HSS TX clock is invalid QV24 Alarms Type Explanation v24CtrlLineLoss The V.24 control lines are not in sync. External Alarm Inputs Type Explanation externalAlarm1 There has been an alarm on external alarm input 1. externalAlarm2 There has been an alarm on external alarm input 2. Remote Terminal Alarms Type Explanation remoteMajorAlarm There has been a major alarm on the remote terminal. remoteMinorAlarm There has been a minor alarm on the remote terminal. Aprisa XE User Manual Alarm Types and Sources | 283 Cross Connect Alarms Type Explanation ccNoBandwidth There is insufficient bandwidth for the current cross connection configuration. MHSB Alarms Type Explanation mhsbSwitchToStandby The terminal has switched from active to standby. HSD Alarms Type Explanation Mode Switch Software Override This alarm provides a warning if the SuperVisor ‘Active Radio’ HSD Control has overwritten the PSC Mode Switch. Companion Tx Fail This alarm occurs on Radio A if the Radio B transmitter (HSD Companion) has failed. This alarm could be caused by a missing RF cable between Radio A and Radio B. hsdCompanionLost This alarm occurs if there is no traffic from the HSD Companion radio. This alarm could be caused by a missing traffic cable between Radio A PSC card and Radio B PIC card. pscMuxAlignmentError This alarm occurs if the TDM mux loses alignment to the TDM bus. This alarm could be caused by a Radio A PSC hardware failure. pscDemuxAlignmentLost This alarm occurs if there is a change in state of the PSC Demux alignment. This alarm could be caused by a HSD system receiver signal loss (both Radio A and Radio B). pscTDMAlignmentLost This alarm occurs if there is a change in state of the PSC TDM alignment. This alarm could be caused by a HSD system receiver signal loss (both Radio A and Radio B) or a Radio A PSC hardware failure. hsdParamMismatch This alarm occurs if there is a parameter setting mismatch between Radio A and Radio B. The Parameter Mismatch alarms only occur if the HSD Control ‘Parameter Compare Checking’ option is set to ‘On’. hsdPMTxPower This alarm occurs if there is a parameter mismatch between Radio A and Radio B transmitter power setting. hsdPMTermRfChWidth This alarm occurs if there is a parameter mismatch between Radio A and Radio B channel size setting. hsdPMTxFreq This alarm occurs if there is a parameter mismatch between Radio A and Radio B transmitter frequency setting. hsdPMRxFreq This alarm occurs if there is a parameter mismatch between Radio A and Radio B receiver frequency setting. hsdPMTermModState This alarm occurs if there is a parameter mismatch between Radio A and Radio B modulation setting. hsdPMModemIntlvEna This alarm occurs if there is a parameter mismatch between Radio A and Radio B modem interleaver setting. Aprisa XE User Manual 284 | Alarm Types and Sources Software Alarms Type Explanation Upload Fail An Upload Fail alarm occurs if the TFTP Upgrade process fails. This can indicate that the upgrade process cannot find the TFTP server or cannot find the software version number entered. defaultImageTableUsed A default image table alarm indicates that the image table has been rebuilt from defaults. This can indicate that an incorrect build of software is running on the terminal. Aprisa XE User Manual Country Specific Settings | 285 17. Country Specific Settings The following table shows the country-specific settings for the DFXO / DFXS interface cards. If the country you want is not listed, contact the local telephone company for assistance. Country DFXO / DFXS Termination / balance impedance DFXO loop current limiter DFXO on-hook speed DFXO ringing impedance DFXO ringing detection threshold Argentina 600Ω On < 500 μs > 1 MΩ 16 Vrms Australia TN12 220Ω + (820Ω ║ 120nF) On 26 ms > 1 MΩ 16 Vrms Austria TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Bahrain TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Belgium TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Brazil 600Ω On < 500 μs > 1 MΩ 16 Vrms Bulgaria 220Ω + (820Ω ║ 120nF) On 3 ms > 1 MΩ 16 Vrms Canada 600Ω On < 500 μs > 1 MΩ 16 Vrms Chile 600Ω On < 500 μs > 1 MΩ 16 Vrms China 600Ω and China 200Ω + (680Ω ║ 100nF) On < 500 μs > 1 MΩ 16 Vrms Colombia 600Ω On < 500 μs > 1 MΩ 16 Vrms Croatia TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Cyprus TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Czech Republic TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Denmark TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Ecuador 600Ω On < 500 μs > 1 MΩ 16 Vrms Egypt TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms El Salvador 600Ω On < 500 μs > 1 MΩ 16 Vrms Finland TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms France TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Germany TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Greece TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Guam 600Ω On < 500 μs > 1 MΩ 16 Vrms Hong Kong 600Ω On < 500 μs > 1 MΩ 16 Vrms Hungary TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Iceland TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms India 600Ω On < 500 μs > 1 MΩ 16 Vrms Indonesia 600Ω On < 500 μs > 1 MΩ 16 Vrms Ireland TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Israel TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Italy TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Japan 600Ω On < 500 μs > 1 MΩ 16 Vrms Jordan 600Ω On < 500 μs > 1 MΩ 16 Vrms Kazakhstan 600Ω On < 500 μs > 1 MΩ 16 Vrms Kuwait 600Ω On < 500 μs > 1 MΩ 16 Vrms Aprisa XE User Manual 286 | Country Specific Settings Latvia TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Lebanon TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Luxembourg TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Macao 600Ω On < 500 μs > 1 MΩ 16 Vrms Malaysia 600Ω On < 500 μs > 1 MΩ 16 Vrms Malta TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Mexico 600Ω On < 500 μs > 1 MΩ 16 Vrms Morocco TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Netherlands TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms New Zealand BT3 (370Ω + (620Ω ║ 310nF)) On < 500 μs > 1 MΩ 16 Vrms Nigeria TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Norway TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Oman 600Ω On < 500 μs > 1 MΩ 16 Vrms Pakistan 600Ω On < 500 μs > 1 MΩ 16 Vrms Peru 600Ω On < 500 μs > 1 MΩ 16 Vrms Philippines 600Ω On < 500 μs > 1 MΩ 16 Vrms Poland TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Portugal TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Romania TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Russia 600Ω On < 500 μs > 1 MΩ 16 Vrms Saudi Arabia 600Ω On < 500 μs > 1 MΩ 16 Vrms Singapore 600Ω On < 500 μs > 1 MΩ 16 Vrms Slovakia TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Slovenia TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms South Africa TBR21 270Ω + (750Ω ║ 150nF) On < 500 μs > 12 kΩ 16 Vrms South Korea 600Ω On < 500 μs > 12 kΩ 16 Vrms Spain TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Sweden TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Switzerland TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms Taiwan 600Ω On < 500 μs > 1 MΩ 16 Vrms Thailand 600Ω On < 500 μs > 1 MΩ 16 Vrms UAE 600Ω On < 500 μs > 1 MΩ 16 Vrms UK BT Network 320Ω + (1050Ω ║ 230nF) and TBR21 270Ω + (750Ω ║ 150nF) On 3 ms > 1 MΩ 16 Vrms USA 600Ω On < 500 μs > 1 MΩ 16 Vrms Yemen 600Ω On < 500 μs > 1 MΩ 16 Vrms Aprisa XE User Manual Specifications | 287 18. Specifications RF Specifications ETSI Frequency Bands ETSI Frequency Bands ETSI Frequency Bands ETSI Frequency Band Frequency Tuning Range Synthesizer Step Size 300 MHz 330 - 400 MHz 6.25 kHz 400 MHz 394 - 460 MHz 5.0 kHz 400 MHz 400 - 470 MHz 6.25 kHz 600 MHz 620 - 715 MHz 12.5 kHz 800 MHz 805 - 890 MHz 12.5 kHz 900 MHz 850 - 960 MHz 12.5 kHz 1400 MHz 1350 - 1550 MHz 12.5 kHz 1800 MHz 1700 - 2100 MHz 62.5 kHz 2000 MHz 1900 - 2300 MHz 62.5 kHz 2500 MHz 2300 - 2700 MHz 62.5 kHz Modulation 16 / 32 / 64 / 128 QAM and QPSK (software configurable) Frequency stability (short term) < ±1 ppm Frequency stability (long term) < ±2 ppm Antenna connector N-type female 50 Ω Note 1 Frequency Ranges Country specific frequency ranges within the above tuning ranges can be accommodated Note 2 Modulation 128 QAM is unreleased: Please contact 4RF for availability. Note 3 Frequency stability Short term frequency stability is defined as changes in frequency due to environmental effects and power supply variations Long term frequency stability is defined as changes in frequency due to aging of crystal oscillators approx over 5 years Aprisa XE User Manual 288 | Specifications Product Range ETSI The Aprisa XE terminal provides the following ETSI frequency bands / channel sizes: Channel Size kHz MHz 25 50 75 125 150 200 250 500 1.00 1.35 1.75 3.50 7.00 14.00 112 256 400 640 808 1.02 1.24 2.39 4.89 6.62 8.63 17.18 35.51 65.46 300 400 Frequency Band MHz 600 800 900 1400 1800 2000 2500 kbit/s Mbit/s Transport capacity @ 64 QAM Product Released Product Release Pending Aprisa XE User Manual Specifications | 289 Link Capacity ETSI Channel size 25 kHz QPSK Gross 72 kbit/s E1 Gross E1 Wayside 75 kHz Gross E1 Wayside 125 kHz Gross E1 Wayside 150 kHz Gross E1 Wayside 200 kHz Gross E1 Wayside 250 kHz Gross E1 Wayside 500 kHz Gross E1 Wayside 1.0 MHz Gross E1 Wayside 1.35 MHz Gross E1 Wayside 1.75 MHz Gross E1 Wayside 3.5 MHz Gross E1 Wayside 7.0 MHz Gross E1 Wayside 14 MHz Gross E1 Wayside Notes 32 QAM 96 kbit/s 1 timeslot Wayside 50 kHz 16 QAM 80 kbit/s 1 timeslot 64 QAM 128 QAM 112 kbit/s 136 kbit/s 1 timeslot 1 timeslot 2 timeslots 8 kbit/s 32 kbit/s 48 kbit/s 8 kbit/s 168 kbit/s 208 kbit/s 256 kbit/s 296 kbit/s 2 timeslots 3 timeslots 4 timeslots 4 timeslots 16 kbit/s 40 kbit/s 16 kbit/s 0 kbit/s 40 kbit/s 128 kbit/s 264 kbit/s 312 kbit/s 400 kbit/s 440 kbit/s 2 timeslots 4 timeslots 4 timeslots 6 timeslots 6 timeslots 0 kbit/s 8 kbit/s 56 kbit/s 16 kbit/s 56 kbit/s 208 kbit/s 424 kbit/s 536 kbit/s 640 kbit/s 744 kbit/s 3 timeslots 6 timeslots 8 timeslots 10 timeslots 11 timeslots 16 kbit/s 40 kbit/s 24 kbit/s 0 kbit/s 40 kbit/s 264 kbit/s 536 kbit/s 672 kbit/s 808 kbit/s 944 kbit/s 4 timeslots 8 timeslots 10 timeslots 12 timeslots 14 timeslots 8 kbit/s 24 kbit/s 32 kbit/s 40 kbit/s 48 kbit/s 336 kbit/s 680 kbit/s 840 kbit/s 1024 kbit/s 1168 kbit/s 5 timeslots 10 timeslots 13 timeslots 16 timeslots 18 timeslots 16 kbit/s 40 kbit/s 8 kbit/s 0 kbit/s 16 kbit/s 408 kbit/s 824 kbit/s 1032 kbit/s 1240 kbit/s 1448 kbit/s 6 timeslots 12 timeslots 16 timeslots 19 timeslots 22 timeslots 24 kbit/s 56 kbit/s 8 kbit/s 24 kbit/s 40 kbit/s 792 kbit/s 1592 kbit/s 1992 kbit/s 2392 kbit/s 2792 kbit/s 12 timeslots 24 timeslots 31 timeslots 1 E1 1 E1 24 kbit/s 56 kbit/s 8 kbit/s 304 kbit/s 704 kbit/s 1624 kbit/s 3256 kbit/s 4072 kbit/s 4888 kbit/s 5704 kbit/s 1 E1 1 E1 24 kbit/s 1168 kbit/s 1984 kbit/s 712 kbit/s 1528 kbit/s 2200 kbit/s 4408 kbit/s 5512 kbit/s 6616 kbit/s 7720 kbit/s 25 timeslots 1 E1 2 E1s 2 E1s 2 E1s 3 E1s 2 E1s 3 E1s 112 kbit/s 232 kbit/s 1336 kbit/s 352 kbit/s 1456 kbit/s 2872 kbit/s 5752 kbit/s 7192 kbit/s 8632 kbit/s 10072 kbit/s 1 E1 2 E1s 3 E1s 4 E1s 4 E1s 784 kbit/s 1576 kbit/s 928 kbit/s 280 kbit/s 1720 kbit/s 5720 kbit/s 11448 kbit/s 14312 kbit/s 17176 kbit/s 20040 kbit/s 2 E1s 5 E1s 6 E1s 8 E1s 9 E1s 1544 kbit/s 1008 kbit/s 1784 kbit/s 472 kbit/s 1248 kbit/s 11832 kbit/s 23672 kbit/s 29592 kbit/s 35512 kbit/s 41432 kbit/s 5 E1s 11 E1s 14 E1s 17 E1s 1392 kbit/s 704 kbit/s 360 kbit/s 16 kbit/s 1760 kbit/s 23992 kbit/s 47992 kbit/s 59992 kbit/s 65464 kbit/s 65400 kbit/s 11 E1s 1024 kbit/s 22 E1s 2056 kbit/s 28 E1s 1528 kbit/s 28 E1s 7000 kbit/s The capacities specified are for Unframed E1 and so require 2088 kbit/s to transport via the radio. The management ethernet capacity must be subtracted from the gross capacity (default 64 kbit/s). See Product Range table for Channel Size / Frequency Band cross reference Aprisa XE User Manual 19 E1s 28 E1s 6936 kbit/s 290 | Specifications Receiver Sensitivity ETSI Channel size QPSK 16 QAM 32 QAM 64 QAM 128 QAM 25 kHz NA -105 dBm -102 dBm -99 dBm -96 dBm 50 kHz -109 dBm -103 dBm -100 dBm -97 dBm -94 dBm 75 kHz -107 dBm -101 dBm -98 dBm -95 dBm -92 dBm 125 kHz -105 dBm -99 dBm -96 dBm -93 dBm -90 dBm 150 kHz -104 dBm -98 dBm -95 dBm -92 dBm -89 dBm 200 kHz -102 dBm -96 dBm -93 dBm -90 dBm -87 dBm 250 kHz -101 dBm -95 dBm -92 dBm -89 dBm -86 dBm 500 kHz -99 dBm -93 dBm -90 dBm -87 dBm -84 dBm 1.0 MHz -96 dBm -90 dBm -87 dBm -84 dBm -81 dBm 1.35 MHz -95 dBm -89 dBm -86 dBm -83 dBm -80 dBm 1.75 MHz -94 dBm -88 dBm -85 dBm -82 dBm -79 dBm 3.5 MHz -90 dBm -84 dBm -81 dBm -78 dBm -75 dBm 7.0 MHz -87 dBm -81 dBm -78 dBm -75 dBm -72 dBm 14 MHz -84 dBm -78 dBm -75 dBm -72 dBm -69 dBm Notes Typical performance specified at the antenna port for 10-6 BER. The receiver is typically 1 dB more sensitive for a BER of 10-3. NA (Not Available) Transmitter Power ETSI Frequency Band QPSK 16 QAM 32 QAM 64 QAM 128 QAM 300 MHz 21 to 35 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 400 MHz 21 to 35 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 600 MHz 21 to 35 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 800 MHz 21 to 35 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 900 MHz 21 to 35 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 1400 MHz 21 to 35 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 1800 MHz 21 to 35 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 2000 MHz 20 to 34 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 2500 MHz 20 to 34 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm Aprisa XE User Manual Specifications | 291 System Gain ETSI Channel Size QPSK 16 QAM 32 QAM 64 QAM 128 QAM 25 kHz NA 136 dB 132 dB 128 dB 125 dB 50 kHz 144 dB 134 dB 130 dB 126 dB 123 dB 75 kHz 142 dB 132 dB 128 dB 124 dB 121 dB 125 kHz 140 dB 130 dB 126 dB 122 dB 119 dB 150 kHz 139 dB 129 dB 125 dB 121 dB 118 dB 200 kHz 137 dB 127 dB 123 dB 119 dB 116 dB 250 kHz 136 dB 126 dB 122 dB 118 dB 115 dB 500 kHz 134 dB 124 dB 120 dB 116 dB 113 dB 1.0 MHz 131 dB 121 dB 117 dB 113 dB 110 dB 1.35 MHz 130 dB 120 dB 116 dB 112 dB 109 dB 1.75 MHz 129 dB 119 dB 115 dB 111 dB 108 dB 3.5 MHz 125 dB 115 dB 111 dB 107 dB 104 dB 7.0 MHz 122 dB 112 dB 108 dB 104 dB 101 dB 14 MHz 119 dB 109 dB 105 dB 101 dB 98 dB Notes Typical performance specified at the antenna port for 10-6 BER. The system gain is typically 1 dB greater for a BER of 10-3. Figures decrease by 1 dB for the 2000 and 2500 MHz bands at QPSK. System Gain = maximum transmit power - receiver sensitivity NA (Not Available) Aprisa XE User Manual 292 | Specifications Link Delays ETSI Note: The default Modem Interleaver Mode setting is on for channel sizes of 250 kHz and greater and off for channel sizes of 200 kHz and less (see ‘Modem Interleaver Mode’ on page 72). Typical 1+0, MHSB end-to-end link delay - interleaver off Channel size 25 kHz QPSK NA 16 QAM 32 QAM 64 QAM 128 QAM 51.8 ms 40.6 ms 35.7 ms 30.3 ms 50 kHz 46.2 ms 24.3 ms 20.2 ms 16.9 ms 15.0 ms 75 kHz 30.4 ms 16.2 ms 14.0 ms 11.4 ms 10.6 ms 125 kHz 22.3 ms 12.1 ms 10.0 ms 8.6 ms 7.0 ms 150 kHz 15.9 ms 8.8 ms 7.3 ms 6.4 ms 5.7 ms 200 kHz 12.8 ms 7.2 ms 6.2 ms 5.3 ms 4.9 ms 250 kHz 10.8 ms 6.2 ms 5.3 ms 4.6 ms 4.2 ms 500 kHz 6.3 ms 3.9 ms 3.4 ms 3.1 ms 2.8 ms 1.0 MHz 3.8 ms 2.6 ms 2.3 ms 2.2 ms 2.1 ms 1.35 MHz 3.1 ms 2.3 ms 2.1 ms 2.0 ms 1.9 ms 1.75 MHz 3.1 ms 2.3 ms 2.1 ms 2.0 ms 1.9 ms 3.5 MHz 2.0 ms 1.7 ms 1.6 ms 1.6 ms 1.6 ms 7.0 MHz 1.7 ms 1.5 ms 1.5 ms 1.5 ms 1.4 ms 14 MHz 1.5 ms 1.4 ms 1.4 ms 1.4 ms 1.4 ms Typical 1+0, MHSB end-to-end link delay - interleaver on QPSK 25 kHz 32 QAM 64 QAM 128 QAM 153.6 ms 118.9 ms 103.5 ms 86.9 ms 50 kHz 138.8 ms 70.5 ms 57.9 ms 47.8 ms 41.8 ms 75 kHz 90.3 ms 46.1 ms 39.5 ms 31.4 ms 28.8 ms 125 kHz 65.6 ms 33.7 ms 27.3 ms 23.1 ms 17.8 ms 150 kHz 45.8 ms 23.7 ms 19.3 ms 16.4 ms 14.3 ms 200 kHz 36.5 ms 19.0 ms 15.8 ms 13.2 ms 11.8 ms 250 kHz 30.4 ms 16.0 ms 13.1 ms 11.2 ms 9.8 ms 500 kHz 16.5 ms 9.0 ms 7.5 ms 6.5 ms 5.7 ms 1.0 MHz 8.8 ms 5.1 ms 4.3 ms 3.9 ms 3.5 ms 1.35 MHz 6.8 ms 4.1 ms 3.6 ms 3.2 ms 2.9 ms 1.75 MHz 5.6 ms 3.5 ms 3.1 ms 2.8 ms 2.9 ms 3.5 MHz 3.5 ms 2.4 ms 2.2 ms 2.1 ms 2.0 ms 7.0 MHz 2.4 ms 1.9 ms 1.8 ms 1.7 ms 1.7 ms 14 MHz 1.9 ms 1.6 ms 1.6 ms 1.5 ms 1.5 ms Notes NA 16 QAM The end to end link delays are measured from E1 / T1 interface to E1 / T1 interface The delay figures are typical and can vary when the system re-synchronizes NA (Not Available) Aprisa XE User Manual Specifications | 293 Typical HSD end-to-end link delay - interleaver on QPSK 25 kHz 16 QAM NA 32 QAM 64 QAM 128 QAM 305.4 ms 223.2 ms 202.2 ms NA 50 kHz 247.1 ms 142.0 ms 122.1 ms 95.2 ms NA 75 kHz 185.3 ms 95.8 ms 82.8 ms 67.0 ms NA 125 kHz NA NA NA NA NA 150 kHz 93.3 ms 47.3 ms 39.5 ms 33.7 ms NA 200 kHz 75.6 ms 38.9 ms 32.7 ms 25.5 ms NA 250 kHz 63.6 ms 32.8 ms 25.2 ms 21.6 ms NA 500 kHz 34.0 ms 17.0 ms 14.8 ms 11.4 ms NA 1.0 MHz 16.9 ms 9.5 ms 8.0 ms 6.5 ms NA 1.35 MHz NA NA NA NA NA 1.75 MHz 9.9 ms 5.1 ms 4.9 ms 4.4 ms NA 3.5 MHz 5.5 ms 3.5 ms 3.1 ms 3.1 ms NA 7.0 MHz 3.6 ms 2.5 ms 2.3 ms 2.3 ms NA 14 MHz 2.4 ms 2.0 ms 2.0 ms 2.0 ms NA Notes The end to end link delays are measured from E1 / T1 interface to E1 / T1 interface The delay figures are typical and can vary when the system re-synchronizes NA (Not Available) Aprisa XE User Manual 294 | Specifications FCC Frequency Bands FCC Frequency Bands FCC Frequency Band Frequency Tuning Range Synthesizer Step Size 400 MHz 421 - 512 MHz 6.25 kHz 700 MHz 698 - 806 MHz 12.5 kHz 900 MHz 928 - 960 MHz 12.5 kHz 2500 MHz 2314 - 2350 MHz 62.5 kHz Modulation 16 / 32 / 64 / 128 QAM and QPSK (software configurable) Frequency stability (short term) < ±1 ppm Frequency stability (long term) < ±2 ppm Antenna connector N-type female 50 Ω Note 1 Frequency bands Contact 4RF for other frequency band options Note 2 Modulation 128 QAM is unreleased: Please contact 4RF for availability. Note 3 Frequency stability Short term frequency stability is defined as changes in frequency due to environmental effects and power supply variations Long term frequency stability is defined as changes in frequency due to aging of crystal oscillators approx over 5 years Product Range FCC The Aprisa XE terminal provides the following FCC frequency bands / channel sizes: Channel Size kHz Frequency Band MHz 25 400 100 MHz 200 250 500 1.00 Part 27 Part 27 Part 90 700 900 Part 101 Part 101 2500 88 424 Part 27 Part 27 1.24 2.39 952 kbit/s Mbit/s Transport capacity @ 64 QAM Promoted Product Release Pending Aprisa XE User Manual 4.98 Specifications | 295 Link Capacity FCC Channel size 25 kHz QPSK Gross Gross 136 kbit/s T1 2 timeslots Wayside Gross Gross 500 kHz T1 1.0 MHz Gross Notes 24 kbit/s 40 kbit/s 280 kbit/s 352 kbit/s 424 kbit/s 608 kbit/s 4 timeslots 5 timeslots 6 timeslots 9 timeslots 312 kbit/s 632 kbit/s 792 kbit/s 952 kbit/s 1112 kbit/s 9 timeslots 12 timeslots 14 timeslots 17 timeslots 56 kbit/s 56 kbit/s 24 kbit/s 56 kbit/s 24 kbit/s 408 kbit/s 824 kbit/s 1032 kbit/s 1240 kbit/s 1448 kbit/s 12 timeslots 16 timeslots 19 timeslots 22 timeslots 24 kbit/s 56 kbit/s 8 kbit/s 24 kbit/s 40 kbit/s 792 kbit/s 1592 kbit/s 1992 kbit/s 2392 kbit/s 2792 kbit/s 1 T1 1 T1 1 T1 1 T1 24 kbit/s 8 kbit/s 408 kbit/s 808 kbit/s 1208 kbit/s 1656 kbit/s 3320 kbit/s 4152 kbit/s 4984 kbit/s 5816 kbit/s T1 1 T1 Wayside 1 timeslot 8 kbit/s 32 kbit/s 12 timeslots Wayside 1 timeslot 56 kbit/s 40 kbit/s 6 timeslots Gross 1 timeslot 128 QAM 104 kbit/s 32 kbit/s T1 Wayside 88 kbit/s 24 kbit/s 4 timeslots Wayside 64 QAM 8 kbit/s T1 250 kHz 72 kbit/s 0 timeslots Wayside 200 kHz 32 QAM 56 kbit/s T1 100 kHz 16 QAM 72 kbit/s 2 T1s 152 kbit/s 2 T1s 984 kbit/s 3 T1s 232 kbit/s 3 T1s 1064 kbit/s The capacities specified are for Unframed T1 and so require 1584 kbit/s to transport via the radio. The management ethernet capacity must be subtracted from the gross capacity (default 64 kbit/s). See Product Range table for Channel Size / Frequency Band cross reference Receiver Sensitivity FCC Channel Size QPSK 16 QAM 32 QAM 64 QAM 128 QAM 25 kHz NA -105 dBm -102 dBm -99 dBm -96 dBm 100 kHz -106 dBm -100 dBm -97 dBm -94 dBm -91 dBm 200 kHz -102 dBm -96 dBm -93 dBm -90 dBm -87 dBm 250 kHz -101 dBm -95 dBm -92 dBm -89 dBm -86 dBm 500 kHz -99 dBm -93 dBm -90 dBm -87 dBm -84 dBm 1.0 MHz -96 dBm -90 dBm -87 dBm -84 dBm -81 dBm Notes Typical performance specified at the antenna port for 10-6 BER. The receiver is typically 1 dB more sensitive for a BER of 10-3. Transmit Power FCC Frequency Band QPSK 16 QAM 32 QAM 64 QAM 128 QAM 400 MHz NA 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 700 MHz 21 to 35 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 900 MHz 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm 2500 MHz 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm Aprisa XE User Manual 296 | Specifications System Gain FCC 400 MHz, 700 MHz, 900 MHz Channel Size QPSK 16 QAM 32 QAM 64 QAM 128 QAM 25 kHz NA 136 dB 132 dB 128 dB 125 dB 100 kHz 135 dB 129 dB 126 dB 123 dB 120 dB 200 kHz 131 dB 125 dB 122 dB 119 dB 116 dB 500 kHz 134 dB 124 dB 120 dB 116 dB 113 dB 1.0 MHz 131 dB 121 dB 117 dB 113 dB 110 dB QPSK 16 QAM 32 QAM 64 QAM 128 QAM 250 kHz 130 dB 124 dB 121 dB 118 dB 115 dB 500 kHz 128 dB 122 dB 119 dB 116 dB 113 dB 2500 MHz Notes Typical performance specified at the antenna port for 10-6 BER. The system gain is typically 1 dB greater for a BER of 10-3. System Gain = maximum transmit power - receiver sensitivity Link Delays FCC Note: The default Modem Interleaver Mode setting is on for channel sizes of 250 kHz and greater and off for channel sizes of 200 kHz and less (see ‘Modem Interleaver Mode’ on page 72). Interleaver off Channel size 25 kHz QPSK NA 16 QAM 32 QAM 64 QAM 128 QAM 64.4 ms 52.3 ms 44.2 ms 38.5 ms 100 kHz 28.8 ms 15.3 ms 12.7 ms 10.9 ms 8.2 ms 200 kHz 15.9 ms 8.8 ms 7.3 ms 6.4 ms 5.1 ms 250 kHz 11.2 ms 6.6 ms 5.4 ms 5.0 ms 4.2 ms 500 kHz 5.9 ms 3.5 ms 3.4 ms 3.2 ms 2.8 ms 1.0 MHz 3.8 ms 2.6 ms 2.3 ms 2.2 ms 2.1 ms Interleaver on Channel size 25 kHz QPSK 32 QAM 64 QAM 128 QAM 191.6 ms 154.1 ms 129.1 ms 111.2 ms 100 kHz 85.3 ms 43.6 ms 35.3 ms 29.7 ms 21.4 ms 200 kHz 45.8 ms 23.7 ms 19.3 ms 16.4 ms 12.3 ms 250 kHz 33.2 ms 17.5 ms 14.3 ms 12.1 ms 9.8 ms 500 kHz 17.5 ms 9.3 ms 8.0 ms 6.9 ms 5.7 ms 1.0 MHz 8.8 ms 5.1 ms 4.3 ms 3.9 ms 3.5 ms Notes NA 16 QAM The end to end link delays are measured from E1 / T1 interface to E1 / T1 interface The delay figures are typical and can vary when the system re-synchronizes Aprisa XE User Manual Specifications | 297 Industry Canada Frequency Bands IC Frequency Bands IC Frequency Band Frequency Tuning Range Synthesizer Step Size 400 MHz 400 - 470 MHz 6.25 kHz 900 MHz 928 - 960 MHz 12.5 kHz 2000 MHz 1900 - 2300 MHz 62.5 kHz Modulation 16 / 32 / 64 / 128 QAM and QPSK (software configurable) Frequency stability (short term) < ±1 ppm Frequency stability (long term) < ±2 ppm Antenna connector N-type female 50 Ω Note 1 Frequency bands Contact 4RF for other frequency band options Note 2 Modulation 128 QAM is unreleased: Please contact 4RF for availability. Note 3 Frequency stability Short term frequency stability is defined as changes in frequency due to environmental effects and power supply variations Long term frequency stability is defined as changes in frequency due to aging of crystal oscillators approx over 5 years Product Range IC The Aprisa XE terminal provides the following Industry Canada frequency bands / channel sizes: Channel Size Freq Band kHz MHz 25 75 100 150 200 500 1.00 1.75 3.50 7.00 14.00 88 400 424 808 952 2.39 4.89 8.63 17.18 35.51 65.46 400 900 2000 kbit/s Mbit/s Transport capacity @ 64 QAM Aprisa XE User Manual 298 | Specifications Link Capacity IC Channel size 25 kHz QPSK Gross NA T1 Gross T1 Wayside 100 kHz Gross T1 Wayside 150 kHz Gross T1 Wayside 200 kHz Gross T1 Wayside 500 kHz Gross T1 Wayside 1.0 MHz Gross T1 Wayside 1.75 MHz Gross T1 3.5 MHz 2 timeslots 88 kbit/s 1 timeslot NA 1 timeslot 56 kbit/s 8 kbit/s 24 kbit/s 264 kbit/s 312 kbit/s 400 kbit/s 4 timeslots 128 QAM 4 timeslots 6 timeslots 440 kbit/s 6 timeslots 0 kbit/s 8 kbit/s 56 kbit/s 16 kbit/s 56 kbit/s 136 kbit/s 280 kbit/s 352 kbit/s 424 kbit/s 608 kbit/s 2 timeslots 4 timeslots 5 timeslots 6 timeslots 9 timeslots 8 kbit/s 24 kbit/s 32 kbit/s 40 kbit/s 32 kbit/s 264 kbit/s 536 kbit/s 672 kbit/s 808 kbit/s 944 kbit/s 4 timeslots 8 timeslots 10 timeslots 12 timeslots 14 timeslots 8 kbit/s 24 kbit/s 32 kbit/s 40 kbit/s 48 kbit/s 312 kbit/s 632 kbit/s 792 kbit/s 952 kbit/s 1112 kbit/s 4 timeslots 56 kbit/s 792 kbit/s 12 timeslots 9 timeslots 12 timeslots 14 timeslots 17 timeslots 56 kbit/s 24 kbit/s 56 kbit/s 24 kbit/s 1592 kbit/s 1992 kbit/s 2392 kbit/s 2792 kbit/s 1 T1 1 T1 1 T1 1 T1 24 kbit/s 8 kbit/s 408 kbit/s 808 kbit/s 1208 kbit/s 1624 kbit/s 3256 kbit/s 4072 kbit/s 4888 kbit/s 5704 kbit/s 1 T1 2 T1s 40 kbit/s 88 kbit/s 904 kbit/s 136 kbit/s 952 kbit/s 2872 kbit/s 5752 kbit/s 7192 kbit/s 8632 kbit/s 10072 kbit/s 1 T1 2 T1s 3 T1s 3 T1s 4 T1s 5 T1s 3 T1s 6 T1s 1000 kbit/s 856 kbit/s 712 kbit/s 568 kbit/s Gross 5720 kbit/s 11448 kbit/s 14312 kbit/s 17176 kbit/s 20040 kbit/s Gross T1 Wayside Gross T1 Wayside Notes 128 kbit/s 64 QAM 1288 kbit/s Wayside 14 MHz 72 kbit/s Wayside T1 7.0 MHz 32 QAM 56 kbit/s 0 timeslots Wayside 75 kHz 16 QAM 3 T1s 7 T1s 9 T1s 10 T1s 12 T1s 968 kbit/s 360 kbit/s 56 kbit/s 1336 kbit/s 1032 kbit/s 11832 kbit/s 23672 kbit/s 29592 kbit/s 35512 kbit/s 41432 kbit/s 7 T1s 14 T1s 18 T1s 22 T1s 26 T1s 744 kbit/s 1496 kbit/s 1080 kbit/s 664 kbit/s 248 kbit/s NA 47992 kbit/s 59992 kbit/s 65464 kbit/s 65400 kbit/s 30 T1s 472 kbit/s 32 T1s 9304 kbit/s 32 T1s 14776 kbit/s The capacities specified are for Unframed T1 and so require 1584 kbit/s to transport via the radio. The management ethernet capacity must be subtracted from the gross capacity (default 64 kbit/s). See Product Range table for Channel Size / Frequency Band cross reference NA (Not Available) Aprisa XE User Manual 32 T1s 14712 kbit/s Specifications | 299 Receiver Sensitivity IC Channel size QPSK 16 QAM 32 QAM 64 QAM 128 QAM 25 kHz NA -105 dBm -102 dBm -99 dBm NA 75 kHz -107 dBm -101 dBm -98 dBm -95 dBm -92 dBm 100 kHz -106 dBm -100 dBm -97 dBm -94 dBm -91 dBm 150 kHz -104 dBm -98 dBm -95 dBm -92 dBm -89 dBm 200 kHz -102 dBm -96 dBm -93 dBm -90 dBm -87 dBm 500 kHz -99 dBm -93 dBm -90 dBm -87 dBm -84 dBm 1.0 MHz -96 dBm -90 dBm -87 dBm -84 dBm -81 dBm 1.75 MHz -94 dBm -88 dBm -85 dBm -82 dBm -79 dBm 3.5 MHz -90 dBm -84 dBm -81 dBm -78 dBm -75 dBm 7.0 MHz -87 dBm -81 dBm -78 dBm -75 dBm -72 dBm 14 MHz NA -78 dBm -75 dBm -72 dBm -69 dBm Notes Typical performance specified at the antenna port for 10-6 BER. The receiver is typically 1 dB more sensitive for a BER of 10-3. NA (Not Available) Transmitter Power IC Frequency Band QPSK 16 QAM 32 QAM 64 QAM 128 QAM 400 MHz 15 to 35 dBm 15 to 31 dBm 15 to 30 dBm 15 to 29 dBm 15 to 29 dBm 900 MHz 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm 15 to 29 dBm 2000 MHz 20 to 34 dBm 17 to 31 dBm 16 to 30 dBm 15 to 29 dBm 15 to 29 dBm 128 QAM System Gain IC Channel Size QPSK 16 QAM 32 QAM 64 QAM 25 kHz NA 136 dB 132 dB 128 dB NA 75 kHz 142 dB 132 dB 128 dB 124 dB 121 dB 100 kHz 135 dB 129 dB 126 dB 123 dB 120 dB 150 kHz 139 dB 129 dB 125 dB 121 dB 118 dB 200 kHz 131 dB 125 dB 122 dB 119 dB 116 dB 500 kHz 133 dB 124 dB 120 dB 116 dB 113 dB 1.0 MHz 130 dB 121 dB 117 dB 113 dB 110 dB 1.75 MHz 128 dB 119 dB 115 dB 111 dB 108 dB 3.5 MHz 124 dB 115 dB 111 dB 107 dB 104 dB 7.0 MHz 121 dB 112 dB 108 dB 104 dB 101 dB 14 MHz NA 109 dB 105 dB 101 dB 98 dB Notes Typical performance specified at the antenna port for 10-6 BER. The system gain is typically 1 dB greater for a BER of 10-3. System Gain = maximum transmit power - receiver sensitivity NA (Not Available) Aprisa XE User Manual 300 | Specifications Link Delays IC Note: The default Modem Interleaver Mode setting is on for channel sizes of 250 kHz and greater and off for channel sizes of 200 kHz and less (see ‘Modem Interleaver Mode’ on page 72). Interleaver off Channel size QPSK 16 QAM 32 QAM 64 QAM 128 QAM 25 kHz NA 49.6 ms 39.4 ms 34.9 ms NA 75 kHz 35.5 ms 19.0 ms 16.8 ms 13.6 ms 10.6 ms 100 kHz 28.8 ms 15.3 ms 12.7 ms 10.9 ms 8.2 ms 150 kHz 17.5 ms 10.1 ms 8.5 ms 7.1 ms 5.7 ms 200 kHz 15.9 ms 8.8 ms 7.3 ms 6.4 ms 5.1 ms 500 kHz 6.3 ms 3.5 ms 3.4 ms 3.2 ms 2.8 ms 1.0 MHz 3.8 ms 2.6 ms 2.3 ms 2.2 ms 2.1 ms 1.75 MHz 3.1 ms 2.3 ms 2.1 ms 2.0 ms 1.9 ms 3.5 MHz 2.6 ms 2.0 ms 1.8 ms 1.8 ms 1.7 ms 7.0 MHz 2.0 ms 1.7 ms 1.6 ms 1.6 ms 1.6 ms 14 MHz NA 1.6 ms 1.5 ms 1.5 ms 1.5 ms Interleaver on Channel size QPSK 16 QAM 32 QAM 64 QAM 128 QAM 25 kHz NA 164.7 ms 127.7 ms 111.8 ms NA 75 kHz 103.7 ms 53.2 ms 45.8 ms 36.4 ms 28.8 ms 100 kHz 85.3 ms 43.6 ms 35.3 ms 29.7 ms 21.4 ms 150 kHz 51.4 ms 26.8 ms 21.9 ms 18.6 ms 14.3 ms 200 kHz 45.8 ms 23.7 ms 19.3 ms 16.4 ms 12.3 ms 500 kHz 16.5 ms 9.3 ms 8.0 ms 6.9 ms 5.7 ms 1.0 MHz 8.8 ms 5.1 ms 4.3 ms 3.9 ms 3.5 ms 1.75 MHz 6.8 ms 4.1 ms 3.6 ms 3.2 ms 2.9 ms 3.5 MHz 5.1 ms 3.2 ms 2.8 ms 2.6 ms 2.4 ms 7.0 MHz 3.5 ms 2.4 ms 2.2 ms 2.1 ms 2.0 ms 14 MHz NA 2.1 ms 1.9 ms 1.8 ms 1.8 ms Notes The end to end link delays are measured from E1 / T1 interface to E1 / T1 interface The delay figures are typical and can vary when the system re-synchronizes NA (Not Available) Aprisa XE User Manual Specifications | 301 Receiver Performance Maximum input level -20 dBm Dynamic range 58 to 87 dB (at 10-6 BER) depending on modulation type and channel size C/I ratio (carrier to interference ratio) C/I ratio = CdB - IdB Co-channel better than 16 dB at QPSK better than 20 dB at 16 QAM better than 23 dB at 32 QAM better than 27 dB at 64 QAM better than 30 dB at 128 QAM 1st adjacent channel better than -5 dB 2nd adjacent channel better than -30 dB Typical performance specified at the antenna port for 10-6 BER. Notes The dynamic range is typically 2 dB greater for a BER of 10-3. Duplexers Code Frequency Band Option A0 300 MHz Standard A1 300 MHz A2 300 MHz B0 TX / RX Min Split Passband Lo Band Hi Band Mounting 9.45 MHz 2 MHz 330 - 400 MHz 330 - 400 MHz External Option 1 5 MHz 0.5 MHz 330 - 400 MHz 330 - 400 MHz External Option 2 20 MHz 3.5 MHz 330 - 400 MHz 330 - 400 MHz External 400 MHz Standard 9.45 MHz 2 MHz 400 - 470 MHz 400 - 470 MHz External B1 400 MHz Option 1 5 MHz 0.5 MHz 400 - 470 MHz 400 - 470 MHz External B2 400 MHz Option 2 20 MHz 3.5 MHz 400 - 470 MHz 400 - 470 MHz External C0 400 MHz Standard 3 MHz 0.5 MHz 470 - 492 MHz 473 - 495 MHz External D0 600 MHz Standard 45 MHz 7 MHz 620 - 715 MHz 620 - 715 MHz Internal E0 700 MHz Standard 30 MHz 7 MHz 698 - 806 MHz 698 - 806 MHz Internal F0 800 MHz Standard 40 MHz 7 MHz 805 - 890 MHz 805 - 890 MHz Internal G0 900 MHz Standard 40 MHz 7 MHz 850 - 960 MHz 850 - 960 MHz Internal G1 900 MHz Option 1 9 MHz 1.5 MHz 928 - 960 MHz 928 - 960 MHz External G2 900 MHz Option 2 9 MHz 1 MHz 928 - 960 MHz 928 - 960 MHz Internal G3 900 MHz Option 3 5.5 MHz 0.5 MHz 900 - 960 MHz 900 - 960 MHz External G4 900 MHz Option 4 3.6 MHz 0.5 MHz 900 - 960 MHz 900 - 960 MHz External H0 1400 MHz Standard 48 MHz 7 MHz 1350 - 1550 MHz 1350 - 1550 MHz Internal H1 1400 MHz Option 1 23.5 MHz 7 MHz 1350 - 1550 MHz 1350 - 1550 MHz Internal K0 1800 MHz Standard 47.5 MHz 14 MHz 1700 - 2100 MHz 1700 - 2100 MHz Internal I0 2000 MHz Standard 91 MHz 14 MHz 1900 - 2300 MHz 1900 - 2300 MHz Internal J0 2500 MHz Standard 74 MHz 14 MHz 2300 - 2700 MHz 2300 - 2700 MHz Internal J1 2500 MHz Option 1 32 MHz 4 MHz 2314 - 2318 MHz 2346 - 2350 MHz Internal Notes All duplexers are bandpass Contact 4RF for other duplexer options Aprisa XE User Manual 302 | Specifications Interface Specifications Ethernet Interface General Diagnostics Interface RJ-45 * 4 (Integrated 4-port switch) Cabling CAT-5 UTP, supports auto MDIX (Standard Ethernet) Maximum line length 100 metres on cat-5 or better Bandwidth allocation n x 8 kbit/s up to maximum available. n x 64 kbit/s is recommended for terminals with higher channel size (> 500 kHz, 32 QAM). Ethernet capacity The ethernet capacity maximum is determined by the lesser of the available radio link capacity or 50 Mbit/s. Maximum packet size ‘Standard’ Ethernet packets: max 1518 octets Tagged and double-tagged packets: max 1526 octets Data buffer size Up to 256 frames Address table size 2048 IP addresses WAN protocol HDLC Ethernet mode 10Base-T or 100Base-TX Full duplex or half duplex (Auto-negotiating and auto-sensing) VLAN tagging IEEE 802.1Q VLAN tagging QoS IEEE 802.1p Ipv4 TOS DiffServ Ipv6 traffic class Spanning Tree Forwards 802.1D Spanning Tree Protocol packets up to 1526 bytes in length. Green LED On: Ethernet signal received Flashing: Indicates data traffic present on the interface Note: Do not connect Power over Ethernet (PoE) connections to the Aprisa XE Ethernet ports as this will damage the port. Aprisa XE User Manual Specifications | 303 QJET Quad E1 / T1 Interface General Standard G.703 and G.704 Interface RJ-45 Line termination impedance E1 120 Ω balanced T1 100 Ω balanced Maximum line length E1 typically up to 1.7 km (43 dB of loss at 1024 kHz in standard 0.4 mm2 cable). T1 typically up to 1.7 km (36 dB of loss at 772 kHz in standard 0.4 mm2 cable). Bandwidth allocation Framed E1s require a link bandwidth of 2048 kbit/s. Unframed E1s require a link bandwidth of 2088 kbit/s. Framed T1s require a link bandwidth of 1544 kbit/s. Unframed T1s require a link bandwidth of 1584 kbit/s. Line code E1 HDB3 or AMI T1 B8ZS or AMI Diagnostics Tx Waveform Shaper (T1 only) 0 ~ 133 ft 133 ~ 266 ft 266 ~ 399 ft 399 ~ 533 ft 533 ~ 655 ft Stability ±50 ppm Jitter performance G.823 (sections 2 & 3) Green LED On: Interface is operational and in service Off: No 2 Mbit/s input signal Flashing: The interface loopback is active. Yellow LED On: Alarm Off: No alarm Aprisa XE User Manual 304 | Specifications Q4EM Quad 4 Wire E&M Interface General Analogue Signalling Diagnostics Audio 64 kbit/s (PCM A-Law as per ITU G.711) 32, 24 and 16 kbit/s (ADPCM as per ITU G.726 and ANSI TI.303) E&M signalling 8 kbit/s per port Maximum line length 400 metres Transmission performance characteristics ITU G.712 E4 for an operating level range of -14 dBr to +4 dBr for a G.711 64 kbit/s coded channel Input level range -14.0 dBr to +4.0 dBr in 0.5 dB steps Output level range -14.0 dBr to +4.0 dBr in 0.5 dB steps Default output level 0 dBr Default input level 0 dBr Maximum level +3.14 dBm0 Port impedance 600 Ω Return loss better than 25 dB over the frequency range 200 - 3600 Hz Transformer isolation 3.88 kV End to end gain Frequency response 0 dB ± 0.1 dB (300-3000 Hz) 0 dB ± 0.5 dB (250-3400 Hz) Audio line protection Secondary protection Signal to total distortion > 30 dB (0 dBm0 to -30 dBm0) > 22 dB (-45 dBm0) E&M Mode independent (external power supply / ground reference required) Pulse distortion 4:1 multiplexed < 2.250 ms Non-multiplexed 250 µs M loop current 5.0 to 6.5 mA (constant current) M detection voltage 9 VDC M maximum voltage 60 VDC E circuit impedance 45 Ω closed > 100 kΩ open Maximum E circuit current 100 mA E maximum voltage 60 V E&M circuit protection E: Current limited to 120 mA, overvoltage to 350 V M: Current limited to 6.5 mA, overvoltage to 100 V Green LED Off: No external source applied to M wire On: External source applied to M wire Flashing: The interface loopback is active Yellow LED Off: E wire relay contact open On: E wire relay contact closed Aprisa XE User Manual Specifications | 305 DFXO Dual Foreign Exchange Office Interface General Analogue Audio 64 kbit/s (PCM as per ITU G.711) 32, 24 and 16 kbit/s (ADPCM as per ITU G.726 and ANSI TI.303) Signalling allocation 8 or 32 kbit/s allocated for CAS (multiplexed / non multiplexed) Companding A-Law or µ-Law Maximum line length 600 metres (2000 feet) on 0.4 mm / 26 AWG copper pair Calling line ID (CLI) Support provided for ETSI: EN 300 659-1 & 2 and BT: SIN 227 and 242 Fax Conforms to G3 standard for 64 kbit/s PCM and 32 kbit/s ADPCM compression Transmission performance characteristics ITU G.712 E2 for an operating level range of -6 dBr to +1 dBr for a G.711 64 kbit/s coded channel Input level range -10 dBr to +1.0 dBr in 0.5 dB steps Output level range -10 dBr to +1.0 dBr in 0.5 dB steps Default Input level -4.0 dBr Default Output level -1.0 dBr Maximum level +3.14 dBm0 Line impedance / Hybrid balance impedance options 600 Ω 900 Ω 600 Ω + 2.16 µF 900 Ω + 2.16 µF 270 Ω + 750 Ω || 150 nF (TBR-21) 220 Ω + 820 Ω || 120 nF (TN12) 370 Ω + 620 Ω || 310 nF (BT3) 320 Ω + 1050 Ω || 210 nF (BT Network) 200 Ω + 680 Ω || 100 nF (China) Return Loss better than 12 dB 300 Hz to 600 Hz better than 15 dB 600 Hz to 3400 Hz Trans hybrid loss better than 13 dB 300 Hz to 3400 Hz better than 17 dB 500 Hz to 2500 Hz (with matched external line and hybrid balance impedance) Common mode rejection ratio better than 40 dB 50 Hz to 3800 Hz Echo Canceller provides up to 64 ms of echo cancellation reduces the echo by more than 15 dB at an input signal level of 10 dBm0. better than 46 dB 600 Hz to 3400 Hz Aprisa XE User Manual 306 | Specifications Signalling DTMF dialing Standard DTMF dialing over the voice channel Pulse dialing Transparent decadic signalling at 7 - 14 PPS with break period limits of 60 - 73 % Pulse distortion 4:1 multiplexed < 2.250 ms Non-multiplexed 250 µs Reversals Line polarity reversal detection Loop current limit maximum of 60 mA with Loop Current Limiter On maximum of 160 mA with Loop Current Limiter Off Metering level sensitivity 12 kHz / 16 kHz billing tone detection with a selectable level sensitivity of -17dBm to -40 dBm in 1dB steps into 200 Ω (60 mV rms to 5 mV rms into 200 Ω). Metering level maximum The maximum level of metering signal the DFXO can tolerate without voice band interference is 0.8 Vrms into 200 Ω. Loop resistance on-hook >1 MΩ Ringing detection threshold Three selectable options of 16 Vrms, 26 Vrms and 49 Vrms ± 20 %. Ringing detection frequency 15 to 50 Hz sine wave Ringing input impedance Two selectable options of >1 MΩ and >12 kΩ Ringing DC offset range tolerance 0 to -75VDC Ringing input voltage maximum up to 100 Vrms Ringing cadence limits Ringing ON: Ringing OFF: min 270 ms 180 ms max 10 secs 4 secs Ringing cadence distortion < 40 ms cadence error on both ring and silent periods Physical Physical interface Dual RJ-45 per port (1 line port, 1 monitor port) Diagnostics Green LED Off: Interface operational but not in service On: Interface in service Flashing: Cadenced ringing on line Yellow LED Off: No interface alarm On: Interface alarm Flashing: The interface loopback is active Aprisa XE User Manual Specifications | 307 DFXS Dual Foreign Exchange Subscriber Interface General Analogue Audio 64 kbit/s (PCM as per ITU G.711) 32, 24 and 16 kbit/s (ADPCM as per ITU G.726 and ANSI TI.303) Signalling Allocation 8 or 32 kbit/s allocated for CAS (multiplexed / non multiplexed) Compression coding A-Law or µ-Law Maximum line length 600 metres (2000 feet) on 0.4 mm / 26 AWG copper pair Calling line ID (CLI) Support provided for ETSI: EN 300 659-1 & 2 and BT: SIN 227 and 242 Fax Conforms to G3 standard for 64 kbit/s PCM and 32 kbit/s ADPCM compression Transmission performance characteristics ITU G.712 E2 for an operating level range of -6 dBr to +2.0 dBr for a G.711 64 kbit/s coded channel Input level range -9.0 dBr to +2.0 dBr in 0.5 dB steps Output level range -9.5 dBr to +2.5 dBr in 0.5 dB steps Default Input level +1.0 dBr Default Output level -6.0 dBr Maximum level +3.14 dBm0 Line impedance / Hybrid balance impedance options 600 Ω 900 Ω 600 Ω + 2.16 µF 900 Ω + 2.16 µF 220 Ω + (820 Ω || 120 nF) (TN12) 270 Ω + (750 Ω || 150 nF) (TBR21) 370 Ω + (620 Ω || 310 nF) (BT3) Return Loss better than 12 dB 300 Hz to 600 Hz better than 15 dB 600 Hz to 3400 Hz Trans hybrid loss better than 13 dB 300 Hz to 3400 Hz better than 17 dB 500 Hz to 2500 Hz (with matched external line and hybrid balance impedance) Common mode rejection ratio better than 40 dB 50 Hz to 3800 Hz better than 46 dB 600 Hz to 3400 Hz Aprisa XE User Manual 308 | Specifications Signalling Physical Diagnostics Feed voltage output -48 V (160 + 160 Ω voltage source current limited) Loop current limit 35 mA ± 10 %. Seize signal Loop start only (no ground start) Loop detect threshold 9 to 12 mA (step function between on hook and off hook) Loop non-seizure current > 6 mA (step function between on hook and off hook) Loop release threshold > 4 mA DTMF dialing Standard DTMF dialing over the voice channel Pulse dialing Transparent decadic signalling at 7 - 14 PPS with break period limits of 60 - 73 % (with loop current > 23 mA) Pulse distortion 4:1 multiplexed < 2.250 ms Non-multiplexed 250 µs Reversals output Line polarity reversal output (optional) Metering output frequency 12 kHz / 16 kHz ± 0.5 %. Metering output voltage Four selectable output voltages of 100 mV, 200 mV, 300 mV and 400 mV rms into 200 Ω ± 20 % sourced via the Line Impedance setting but limited to a maximum open circuit voltage of 1 Vrms. Metering output distortion Billing tone total distortion < 5 %. Ringer waveform Sinusoidal with a maximum total distortion of 10% (into 3 REN load) Ringer voltage (open circuit) Five selectable ringer output voltages sourced via an internal ringing resistance of 178 per port. The ringing output is a composite balanced AC ringing voltage with a differential DC offset voltage. 60 Vrms + 0 VDC 55 Vrms + 10 VDC 50 Vrms + 18 VDC 45 Vrms + 22 VDC 40 Vrms + 24 VDC Both the DC and AC components have a tolerance of ± 5%. Ringer output frequency Three selectable options of 17, 25 or 50 Hz ± 5% Ringer output power 60 Vrms source into a load of 2 REN 45 Vrms source into a load of 3 REN (1 REN 6930 F) Ring trip Ring trip will ocurr in < 150 ms following DC loop of > 20 mA Ring trip immunity Ring trip will not ocurr if the DFXS outputs ringing into a load of 500 in series with 4.4 F or less. Physical interface Dual RJ-45 per port (1 line port, 1 monitor port) Line protection Secondary protection (4RF recommends the use of external primary protection in lightning prone areas) Green LED Off: Interface operational but not in service On: Interface in service Flashing: Cadenced ringing on line Yellow LED Off: No interface alarm On: Interface alarm Flashing: The interface loopback is active Aprisa XE User Manual Specifications | 309 QV24 Quad V.24 Serial Data Interface General Interface ITU-T V.24 / EIA/TIA RS-232E Interface direction DCE only Bandwidth allocation 8 to 120 kbit/s in 8 kbit/s steps (dependent on rate selected) Control line allocation 8 kbit/s Maximum line length 10 metres Data clamp Mark hold when out of sync. Control line clamp Off when loss of sync. Clock Internally generated from 2.048 MHz system clock (synchronized at both ends) Transparent mode Operation is completely transparent but limited to 0-600 bit/s Standard mode data bits 7 or 8 bits Standard mode parity Transparent (enable / disable) Standard mode stop bits 1 or 2 bits Asynchronous Data rates 300, 600, 1200, 2400, 4800, 7200, 9600, 12800, 14400, 19200, 23040, 28800, 38400, 57600 and 115200 bit/s Control signals End-to-end CTS to RTS, DSR to DTR Diagnostics Green LED Indicates RX data traffic present Yellow LED Indicates TX data traffic present Async parameters QV24S Quad V.24 Serial Data Interface General Interface ITU-T V.24 / EIA/TIA RS-232E Interface direction DCE only Bandwidth allocation 8 to 120 kbit/s in 8 kbit/s steps (dependent on rate selected) Control line allocation 8 kbit/s Maximum line length 10 metres Data clamp Mark hold when out of sync. Control line clamp Off when loss of sync. Synchronous Data rates 300, 600, 1200, 2400, 4800, 9600 and 19200 bit/s Control signals End-to-end CTS to RTS Diagnostics Green LED Indicates RX data traffic present Yellow LED Indicates TX data traffic present Aprisa XE User Manual 310 | Specifications HSS Single High Speed Synchronous Data Interface General Diagnostics Interfaces ITU-T V.35 ITU-T X.21 EIA RS-449 EIA RS-530 Bandwidth allocation 8 to 2048 kbit/s in 8 kbit/s steps (dependent on rate selected) 8 kbit/s for control lines Maximum line length 3 metres Clock Internally generated from 2.048 MHz system clock (synchronized at both ends) on DCE to DCE mode. Clock provided by external DCE when in DTE mode. Remote DCE outputs clock-timed by incoming clock at DTE. Top Green LED On: Normal operation Flashing: Loopback Lower Green LED On: Normal operation External Alarm Interfaces Alarm inputs Alarm outputs Overall Detector type Isolated current detectors Detection current 5.0 to 6.5 mA (constant current) Detection voltage 9 to 60 VDC or AC rms Contact type Isolated semiconductor relay type contacts Maximum current 100 mA Maximum voltage 0 to 60 VDC or AC rms Ouput impedance 45 Ω closed > 100 kΩ open Latency The latency for an alarm presented on an external alarm input to the alarm being output on an external alarm output is < 2 seconds Auxiliary Interfaces Management Configuration and management Embedded web server and / or SNMP accessed via Ethernet interface or across link Test points RSSI Front panel test point for measuring the RSSI voltage Aprisa XE User Manual Specifications | 311 Power Specifications AC Power Supply Nominal voltage Input voltage range Maximum Power input Max VA Frequency 115 VAC 103 - 127 Vrms 180 W 400 VA 47 - 63 Hz 230 VAC 207 - 254 Vrms 180 W 400 VA 47 - 63 Hz Nominal voltage Input voltage range Maximum Power input Maximum input current Recommended DC breaker rating +12 VDC LP 10.5 to 18 VDC 53 W 5A 8A ±12 VDC 10.5 to 18 VDC 180 W 18 A 25 A ±24 VDC 20.5 to 30 VDC 180 W 8A 10 A ±48 VDC 40 to 60 VDC 180 W 4A 5A DC Power Supply Aprisa XE User Manual 312 | Specifications Power Consumption Terminal Type Power Consumption (min – max) Standard Aprisa XE 1+0 terminal 34 to 170 W Input power (dependent on the transmitter output power, the interface cards fitted and the power supply option) Standard Aprisa XE 1+1 terminal 74 to 375 W Input power (dependent on the transmitter output power, the interface cards fitted, the number of trib switches and the power supply option) Standard Aprisa XE HSD terminal 68 to 286 W Input power (dependent on the transmitter output power, the interface cards fitted and the power supply option) Power Consumption Model An Aprisa XE Power Consumption model program called XEpower is on the Aprisa XE CD. This program shows the typical power consumption for any product configuration. Java 1.6 is required to be installed on your PC to run this program. Standard Aprisa XE 1+0 terminal – 48 VDC These power consumption figures represent the typical power drawn by a single standard 1400 MHz 1+0 terminal measured at the input to a ± 48 VDC power supply. Power Consumption (min – max) 40 to 150 W Input power (dependent on interface cards fitted and transmitter output power level) Terminal only: TX power of + 20 dBm 44 W TX power of + 25 dBm 54 W TX power of + 30 dBm 61 W TX power of + 35 dBm 64 W Interface cards: QJET four port E1 card 2.3 W (four ports operating) Q4EM four port 4W E&M card 0.6 W (all states) QV24 four port V.24 card 0.2 W (all states) DFXO two port 2W FXO card 0.7 W (all states) DFXS two port 2W FXS card One DFXS card installed with both ports idle (on hook): 2.5 W Plus: 1.9 W / line off-hook (200 ohm copper loop plus 450 ohm telephone) 1.0 W / line ringing (60 Vrms 25Hz source via 100 ohm copper loop into a 1 REN load) 1.5 W / line ringing (45 Vrms 25Hz source via 100 ohm copper loop into a 3 REN load) HSS single port high speed data 1.0 W (all states) MHSB: Tributary and RF switch 13 W not switched 25 W switched Aprisa XE User Manual Specifications | 313 Low Power Aprisa XE 1+0 terminal – 12 VDC These power consumption figures represent the typical power drawn by a single low power 1400 MHz 1+0 terminal measured at the input to a low power +12 VDC power supply. Power Consumption (min – max) 34 to 53 W Input power (dependent on interface cards fitted and transmitter output power level) Terminal only: TX power of + 20 dBm 34 W TX power of + 24 dBm 40 W Interface cards: QJET four port E1 card 1.9 W (four ports operating) Q4EM four port 4W E&M card 0.53 W (all states) QV24 four port V.24 card 0.15 W (all states) DFXO two port 2W FXO card 0.56 W (all states) DFXS two port 2W FXS card One DFXS card installed with both ports idle (on hook): 2.1 W Plus: 1.6 W / line off-hook (200 ohm copper loop plus 450 ohm telephone) 0.8 W / line ringing (60 Vrms 25Hz source via 100 ohm copper loop into a 1 REN load) 1.2 W / line ringing (45 Vrms 25Hz source via 100 ohm copper loop into a 3 REN load) HSS single port high speed data 0.85 W (all states) Aprisa XE User Manual 314 | Specifications Protection System Specifications MHSB Protection MHSB switches RF switch Tributary switch Switching time < 25 ms from detection of alarm condition Switch hysteresis 30 seconds (to prevent switching on short alarm transients) RF path restore time < 10 seconds TX relay / cable loss 1.0 dB RX splitter / cable loss 4.0 dB Total system loss System gain reduced by a maximum of 5 dB Ports HSD Protection TX path TX relay / cable loss Switching times Transmit path < 25 ms from detection of alarm condition Receive path Hitless 1.0 dB Aprisa XE User Manual Specifications | 315 General Specifications Environmental Operating range -10 to +50˚ C Storage range -20 to +70˚ C Humidity Maximum 95% non-condensing Acoustic noise emission 59 dBA (A-weighted Sound Power Level) Mechanical Height Standard terminal 2 U high (internal duplexer) 3 – 4 U high (depending on external duplexer type) MHSB terminal 6 U high (internal duplexer) 7 – 8 U high (depending on external duplexer type) HSD terminal 4 U high (internal duplexer) 6 – 8 U high (depending on external duplexer type) Width 19-inch rack mount 434 mm (without mounting brackets attached) 483 mm (with mounting brackets attached) Depth 372 mm Colour Pure black Weight Standard terminal 8 kg (internal duplexer) 9 - 12 kg (depending on external duplexer type) MHSB terminal 25 kg (internal duplexer) 26 – 29 kg (depending on external duplexer type) HSD terminal 17 kg (internal duplexer) 19 – 24 kg (depending on external duplexer type) ETSI Compliance Radio EN 301 751, EN 300 630 EN 302 217 Parts 1, 2.1, and 2.2 EMI/EMC EN 301 489 Parts 1 & 4 Safety EN 60950 CSA 253147 applicable for AC, 48 VDC and 24 VDC product variants Environmental ETS 300 019 Class 3.2 Aprisa XE User Manual Product End Of Life | 317 19. Product End Of Life End-of-Life Recycling Programme (WEEE) The WEEE Directive concerns the recovery, reuse, and recycling of electronic and electrical equipment. Under the Directive, used equipment must be marked, collected separately, and disposed of properly. 4RF Limited has implemented an end-of-life recycling programme to manage the reuse, recycling, and recovery of waste in an environmentally safe manner using processes that comply with the WEEE Directive (EU Waste Electrical and Electronic Equipment 2002/96/EC). The WEEE Symbol Explained This symbol appears on Electrical and Electronic Equipment (EEE) as part of the WEEE (Waste EEE) directive. It means that the EEE may contain hazardous substances and must not be thrown away with municipal or other waste. WEEE Must Be Collected Separately You must not dispose of electrical and electronic waste with municipal and other waste. You must separate it from other waste and recycling so that it can be easily collected by the proper regional WEEE collection system in your area. YOUR ROLE in the Recovery of WEEE By separately collecting and properly disposing of WEEE, you are helping to reduce the amount of WEEE that enters the waste stream. One of the aims of the WEEE directive is to divert EEE away from landfill and encourage recycling. Recycling EEE means that valuable resources such as metals and other materials (which require energy to source and manufacture) are not wasted. Also, the pollution associated with accessing new materials and manufacturing new products is reduced. EEE Waste Impacts the Environment and Health Electrical and electronic equipment (EEE) contains hazardous substances which have potential effects on the environment and human health. If you want environmental information on the Aprisa XE terminal, contact us (on page 19). Aprisa XE User Manual Abbreviations | 319 20. Abbreviations ADC Analogue to Digital Converter H/W Hardware ADPCM Adaptive Differential Pulse Code Modulation IC Integrated Circuit IF Intermediate Frequency ADSL Asymmetrical Digital Subscriber Line IP Internet Protocol AGC Automatic Gain Control I/O Input/Output AMP Amplifier ISP Internet Service Provider BER Bit Error Rate kbit/s Kilobits per second CAS Channel Associated Signalling kHz Kilohertz CPE Customer Premises Equipment LAN Local Area Network CLI Calling Line Identification LED Light Emitting Diode DAC Digital to Analogue Converter LOS Loss of Signal dB Decibels mA Milliamps dBc Decibels relative to carrier power MAC Media Access Control dBm Decibels relative to 1 mW Mbit/s Megabits per second dBr Decibels relative to the transmission reference point MHSB Monitored Hot Standby MHz Megahertz DCE Data Communications Equipment MIB Management Information Base DTE Data Terminal Equipment MTBF Mean Time Between Failures DTI Digital Trunk Interface MTTR Mean Time To Repair E&M Ear and Mouth ms milliseconds EMC Electro-Magnetic Compatibility NFAS EMI Electro-Magnetic Interference Not Frame Alignment Signal (E1 frame) ESD Electro-Static Discharge NMS Network Management System ETSI European Telecommunications Standards Institute OSI Open Systems Interconnection PABX FAS Frame frame) Private Exchange PBX Private Branch Exchange FEC Forward Error Correction PC Personal Computer FFE Feed Forward Equalizer PCM Pulse Code Modulation F/W Firmware PCA Printed Circuit Assembly FXO Foreign Exchange Office PLL Phase Locked Loop FXS Foreign Exchange Subscriber POP Point of Presence GSM Global System communications POTS Plain Old Telephone Service ppm Parts Per Million PSTN Public Switched Network PMR Public Mobile Radio Alignment Signal for (E1 Mobile HSC Hardware Software Compatibility HSS High-Speed Synchronous Serial Aprisa XE User Manual Automatic Branch Telephone QAM Quadrature Amplitude Modulation QPSK Quadrature Phase Shift Keying RAI Remote Alarm Indicator RF Radio Frequency RoHS Restriction Substances of RSSI Received Indication Signal RX Receiver SNMP Simple Network Protocol SNR Signal to Noise Ratio SWR Standing Wave Ratio TCP/IP Transmission Control Protocol/Internet Protocol Hazardous Strength Management TCXO Temperature Crystal Oscillator Compensated TETRA Terrestrial Trunk Radio TFTP Trivial File Transfer Protocol TMR Trunk Mobile Radio TX Transmitter UTP Unshielded Twisted Pair VAC Volts AC VCO Voltage Controlled Oscillator VDC Volts DC VoIP Voice over Internet Protocol WEEE Waste Electrical and Electronic Equipment Acknowledgments and Licensing | 321 21. Acknowledgments and Licensing The Aprisa XE product software runs the GNU Linux Operating System and incorporates several other packages in accordance with the free software philosophy. The following list identifies the licensed software used: BusyBox Description: Tiny versions of common UNIX utilities Reference: http://busybox.net/ License Type: GNU General Public License (GPL) DropBear SSH Server Description: Small and secure SSH Server Reference: http://matt.ucc.asn.au/dropbear/ License Type: MIT Style License GoAhead WebServer 2.1 Description: Embedded Web Server Reference: http://webserver.goahead.com/ License Type: Private License Linux Kernel Description: Linux Kernel version 2.4.26 Reference: http://www.kernel.org/ License Type: GNU General Public License (GPL) Net-SNMP Description: Various tools relating to SNMP Reference: http://www.net-snmp.org/ License Type: CMU/UCD and BSD License uClibc Description: C library for embedded Linux systems Reference: http://uclibc.org/ License Type: GNU Lesser General Public License (LGPL) U-Boot Description: Bootloader Reference: http://u-boot.sourceforge.net/ License Type: GNU General Public License (GPL) Aprisa XE User Manual 322 | Acknowledgments and Licensing Software Licensed Under the GPL Some of the above packages licensed under the GPL have been modified by 4RF Limited. The copyright holders of these modified packages (including 4RF Limited) agree to them being distributed under the terms of the General Public License. Copies of the GNU General Public License (GPL) and Lesser General Public License (LGPL) can be obtained from the Free Software Foundation Inc, 59 Temple Place - Suite 330, Boston, MA, 02111-1307, USA. Plain text copies of these licenses can also be found at: http://www.gnu.org/licenses/gpl.txt http://www.gnu.org/licenses/lgpl.txt If you would like a copy of the GPL source code used in this product on a CD, please send US$50.00 (to cover the preparation of the CD and transport costs) to 4RF Limited, PO Box 13-506, Wellington, New Zealand. Software Licensed Under Other Licenses The following copyright notices are included for packages not covered by the GPL: Dropbear SSH Server (MIT License) Dropbear—a SSH2 server Copyright © 2002, 2003 Matt Johnston All rights reserved Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the ‘Software’), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED ‘AS IS’, WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. Aprisa XE User Manual Acknowledgments and Licensing | 323 Net-SNMP Part 1: CMU/UCD (BSD like) Copyright © 2001-2003, Networks Associates Technology, Inc All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. Neither the name of the Networks Associates Technology, Inc nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ‘AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Part 2: Networks Associates Technology, Inc. (BSD) Copyright © 2001-2003, Networks Associates Technology, Inc All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. Neither the name of the Networks Associates Technology, Inc nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ‘AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Aprisa XE User Manual 324 | Acknowledgments and Licensing Part 3: Cambridge Broadband Ltd (BSD) Portions of this code are copyright © 2001-2003, Cambridge Broadband Ltd. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. The name of Cambridge Broadband Ltd. may not be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER ‘AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Part 4: Sun Microsystems, Inc. (BSD) Copyright © 2003 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Use is subject to license terms below. This distribution may include materials developed by third parties. Sun, Sun Microsystems, the Sun logo and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. Neither the name of the Sun Microsystems, Inc. nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ‘AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Aprisa XE User Manual Acknowledgments and Licensing | 325 Part 5: Sparta, Inc. (BSD) Copyright © 2003-2004, Sparta, Inc All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. Neither the name of the Networks Associates Technology, Inc nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ‘AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. GoAhead WebServer (Private License) GoAhead WebServer Copyright (c) 2000 GoAhead Software, Inc. All Rights Reserved Aprisa XE User Manual Commissioning Form | 327 22. Commissioning Form Aprisa XE User Manual Index | 329 23. Index 2 wire 105 4 wire 102 AC power supply access rights accessory kit AIS alarms alarm summary clearing alarms E1 / T1 alarm conditions external history identifying causes interface alarms saving history termination types A-law antennas aligning checking polarization corner reflector directional antennas installing parabolic selection and siting siting yagi attenuators 38 63 19 250 242 247 250 33 244 248 246 245 33 273 110 197 197 23 21, 22 32 21 21 23 22 41 balun transformer basic terminal settings bench setup BER brownout recovery module browser cache, clearing 256 72 41 203 39 222 cabling accessory kit 19 coaxial feeder 24, 41 for HSD 189 for MHSB 183 shielded 262 cache, clearing 221, 222 CAS 110, 159, 160, 161, 162 Castle Rock 83 CD contents 18 clock source setting for 100, 131 compatibility of interfaces 156 configuration files 224 configuration, saving 87, 153 constellation analyser 205 corner reflector antenna 23 country specific settings 283 cross connections creating 150 deleting 155 drop and insert 152 point to point 150 printing 154 saving configurations 153 selecting timeslots 164 sending configurations 153 Symmetrical Connection Wizard 174 cross connections application about 145 ethernet capacity 148 getting configurations 149 installing 144 required system configuration for 143 toolbar 147 total assigned link capacity 145 user capacity 148 DC power supply DCD mode declaration of conformity DFXO interface card country specific settings cross connections for Aprisa XE User Manual 35 135 iii 118 283 169 330 | Index interface connections for port settings for signalling for DFXS interface card country specific settings cross connections for interface connections for port settings for signalling for directional antennas Drop & Insert capacity DSR DTR mode duplexer parameters 262 118 169 110 283 169 261 110 169 21, 22 146 134 77 E&M interface E1 alarm conditions framed unframed earthing environmental requirements error counters Ethernet capacity port status Quality of Service VLAN tagging exchange end external alarms configuring inputs mapping outputs 102 250 158, 159 158 24, 26, 41 25 203 148 98 94 91 118 79 79 81 81 180 gateway factory default 62 handshaking DCD mode 135 DSR DTR mode 134 RTS CTS mode 133 hardware accessory kit 19 installing 31, 32 hitless 188 HSD 188 cabling 189 configuring terminals 191 IP addresses 190 HSS clocking clocking types 137 cloud mode 141 internal clocking 137 pass-through clocking 137 pipe mode 138 primary/secondary master clocking 137 synchronous clock selection modes 136 HSS interface card 131 cross connections for 172 handshaking 133 interface connections for 263 port settings for 131 humidity 25 fade margin fault finding feeder cables framed mode framed modes PCM30C mode PCM31C mode T1 ESF modes T1 SF modes frequency bands frequency bands ETSI front panel connections indicators tributary switch 202 201, 239, 251 24 158 159 159 161, 162 160 27 285 29 29 image files updating table of in-service commissioning installation interface cabling interface cards before installing configuring installing port settings summary types interface connections DFXO Aprisa XE User Manual 226 230 195 31, 33 34 234 90 236 90 89 30 255 262 Index | 331 DFXS Ethernet HSS Q4EM QJET QV24 QV24S interface pinouts HSS interface traffic direction interfaces, compatibility IP address factory defaults network terminal understanding 261 257 263 258 256 271 271 263 255 156 62 52 73 51 Java clearing cache requirement for 221 18, 47, 143 clearing alarms for 187 configuring radios for 184 configuring the terminals 186 front panel RF protection switch ................... 181 hot stand-by 179 IP addressing 184 monitored hot stand-by 179 mounting 185 power supply 183 slave tributary switch 182 standby mode 181 tributary switch front panel ............................... 180 MIB saving 87 minor alarms, mapping 81 modify user group 63 mounting kit 19 operating temperature 25 LEDs identifying colours 248 interface 256, 257, 258, 261, 262, 263 RF protection switch 182 tributary protection switch 181 lightning protection 26 link budget 24 link capacity, assigned 146 link performance 201, 205 LOF 250 logging in SuperVisor 58 Loop interface circuits 105 loopbacks about 239 interface lookbacks 240 timeslot loopbacks 241 LOS 250 maintenance major alarms, mapping management ethernet capacity MHSB cabling 211 81 148 179 183 passwords changing 65 path planning 21 path propagation calculator 21 PCM modes 158, 159, 160, 161, 162 performance, of link 201, 205, 206 performance, save history 207 pinouts 262 DFXS 261 Ethernet 257 Q4EM 258 QJET 256 QV24 271 QV24S 271 Synchronous cable assemblies 264 POTS 105, 110, 118 power AC power 38 DC cabling 36 DC power 35 power supply 25, 35 powering up 196 protected terminals HSD 188 MHSB 179 Aprisa XE User Manual 332 | Index Q4EM interface card cross connections for 168 E&M signalling types 259 interface connections for 258 port settings for 102 QJET interface card cross connections for 157 interface connections for 256 modes 158, 159, 160, 161, 162 port settings for 100 Quality of Service (QoS) 94 QV24 interface card 126, 127 baud rate 170 cross connections for 170 interface connections for 271 port settings for 126, 127 QV24S interface card 128 interface connections for 271 port settings for 128 rack space RAI rebooting the terminal receiver RF protection switch front panel LEDs RF settings modem performance RS-449 synchronous data RS-530 synchronous data RSSI alarm threshold aligning the antennas RTS CTS mode 31 250 231 28 181 182 67 70 131 131 78 199 133 MIB details setting access controls setting trap destinations viewing traps Space Diversity specifications auxiliary interfaces DFXO interface DFXS interface environmental ethernet interface ETSI external alarms interface general HSS interface MHSB Q4EM interface QJET interface QV24 interface QV24s interface static damage, avoiding storage temperature subnet mask factory default subscriber end SuperVisor logging into logging out opening page PC requirements for PC settings for Surveyor syslog error logging remote logging system performance specifications ETSI 86 84 85 86 188 285 308 303 305 313 300 313 308 313 308 312 302 301 307 307 236 25 62 110 57 58 59 60 47 48 21 251 251 253 285 safety earth setup menu COM port settings Hyperterminal setup basic settings signalling mode slots configuring terminal SNMP T1 40 44 44 55 169 238 30 83 alarm conditions framed unframed temperature terminal alarm summary applying power clocking earthing installing logging into Aprisa XE User Manual 250 158, 160, 161, 162 158 25 242 196 74 26, 40, 41 31 58 Index | 333 logging out modules near and far, explained operating conditions power supplies rebooting upgrading terminal emulator test equipment TFTP server timed reboot timeslots PCM modes selecting tools traffic direction of interfaces tranformer, Balun transmitter tributary switch LEDs troubleshooting 59 28 51 25 35 231 224 87 204 219 231 X.21 synchronous data 159 164 31 255 256 28 181 239 unframed mode upgrading the terminal uploading system files user ethernet capacity users access rights adding changing passwords deleting disabling saving user information session details user groups view user group 158 224 148 63 63 65 64 64 64 65 63 63 V.24 serial data V.35 synchronous data 126, 127, 128 131 web browser cache, clearing WEEE 222 315 Aprisa XE User Manual 131
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Doug.Connor Create Date : 2012:07:26 13:35:13+12:00 Modify Date : 2012:08:01 13:33:48-07:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2012:08:01 13:33:48-07:00 Creator Tool : Microsoft® Office Word 2007 Format : application/pdf Title : Aprisa XE User Manual Creator : Doug.Connor Document ID : uuid:81bb271e-1015-4e9a-856d-3450ad4e5bad Instance ID : uuid:51290228-1dc4-461f-991e-22ab53797911 Producer : Microsoft® Office Word 2007 Page Count : 153EXIF Metadata provided by EXIF.tools