4RF N0700AAAA0000A Aprisa XE 700-bbb-vv User Manual Aprisa XE

4RF Limited Aprisa XE 700-bbb-vv Aprisa XE

Contents

User Manual 2

Download: 4RF N0700AAAA0000A Aprisa XE 700-bbb-vv User Manual Aprisa XE
Mirror Download [FCC.gov]4RF N0700AAAA0000A Aprisa XE 700-bbb-vv User Manual Aprisa XE
Document ID1765065
Application IDtV2NUijTnd0XMf72rYXyNg==
Document DescriptionUser Manual 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize244.51kB (3056436 bits)
Date Submitted2012-08-13 00:00:00
Date Available2012-08-13 00:00:00
Creation Date2012-07-26 13:35:13
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2012-08-01 13:33:48
Document TitleAprisa XE User Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Doug.Connor

Protected Terminals | 181
11. Protected Terminals
Monitored Hot Stand By (MHSB)
This section describes configuring the protected terminal in MHSB mode.
A protected terminal in MHSB mode comprises two radios interconnected using a MHSB switch. This MHSB
switch comprises one RF switch and up to four tributary switches depending on the number of tributaries
requiring switching:
The MHSB switch protect terminals against any single failure in one radio. It also monitors the alarm
output of each radio and switches between radios if major radio link alarms occur. The MHSB switch will
not allow a switch to a faulty radio.
The MHSB switch uses a CPU to monitor the alarm status received from both the connected radios' alarm
ports. When a relevant major radio link alarm is detected on the active radio (that is, transmitter,
receiver, power supply or modem), the CPU switches a bank of relays that switches all the interfaces and
the transmit port from the main radio to a functioning stand-by radio. The stand-by radio now becomes
the active radio.
The MHSB switch has a hysteresis of 30 seconds to prevent switching on short alarm transients.
The tributary switch and the RF switch are both a 19-inch rack-mount 1U high chassis. The MHSB switch
option is available for all Aprisa XE frequency bands.
Aprisa XE User Manual
182 | Protected Terminals
Tributary Switch Front Panel
No.
Description
Explanation
Power supply input
Input for DC power or AC power
Protective earth
M5 terminal intended for connection to an external protective
conductor for protection against electric shock in case of a fault
Interface ports
Port for connecting to customer interface equipment
Radio A interfaces
These connect to the interface ports on radio A
Radio B interfaces
These connect to the interface ports on radio B
Console
For factory use only
Ethernet
Port for connecting to customer Ethernet network. This port is
also used to set up and manage the radios remotely over an IP
network
Radio A Ethernet
Connects to an Ethernet port on radio A
Radio B Ethernet
Connects to an Ethernet port on radio B
10
Alarms
Alarm input/output connections for customer equipment
11
Radio A alarms
Connects to the alarm port on radio A
12
Radio B alarms
Connects to the alarm port on radio B
13
RF SW
Provides power and signalling to the RF switch
14
Mode switch
Three-position locking toggle switch to set the MHSB switch into
automatic mode or radio A / radio B test mode
15
LEDs
Mode and status LEDs
Aprisa XE User Manual
Protected Terminals | 183
Tributary Protection Switch LEDs
LED
Colour
Appearance
Explanation
Green
Solid
The radio is active and is OK
Green
Flashing
The radio is in standby mode and is OK
Red
Solid
The radio is active and there is a fault
No colour (off)
The tributary switch is in 'slave' mode and the
switching is controlled by the master tributary
switch
Red
Flashing
The radio is in standby mode, and there is a fault
Green
Solid
The radio is active and is OK
Green
Flashing
The radio is in standby mode and is OK
Red
Solid
The radio is active and there is a fault
No colour (off)
The tributary switch is in 'slave' mode and the
switching is controlled by the master tributary
switch
Red
Flashing
The radio is in standby mode, and there is a fault
Green
Solid
The tributary protection switch is in 'auto' mode
Green
Flashing
The tributary protection switch is in 'slave' mode
Red
Solid
The tributary protection switch is in 'manual'
mode (A or B)
Blue
Solid
Indicates that there is power to the tributary
protection switch
On
RF Switch Front Panel
No.
Description
Explanation
Radio QMA
QMA connectors for connecting the protected radios
Protective earth
M5 terminal intended for connection to an external protective
conductor for protection against electric shock in case of a fault
Antenna port
N-type female connector for connection to the antenna feeder
cable. This view shows an internally mounted duplexer. If an
external duplexer is fitted, the antenna port will be on the
external duplexer
Slave tributary
switch outputs
Connects to secondary tributary switch for control of additional
interfaces
Tributary switch
Connects the RF switch to the tributary switch (the master if
more than one tributary switch is required)
LEDs
Status LEDs
Aprisa XE User Manual
184 | Protected Terminals
RF Protection Switch LEDs
LED
Colour
Appearance
Explanation
Tx A
Green
Solid
RF is being received from radio A
Tx B
Green
Solid
RF is being received from radio B
On
Blue
Solid
Indicates that there is power to the RF protection switch
Slave Tributary Switches
Each tributary switch protects up to eight ports. Up to three slave tributary switches may be added to a
MHSB terminal to protect up to 32 ports. Each slave tributary switch is interconnected by means of the
slave tributary switch ports on the RF switch, as shown below.
Note: A tributary switch that is operating as a slave (rather than a master) has a RJ-45 V.24 loopback
connector plugged into the console port. If the connector is missing, contact Customer Support.
Alternatively, you can make this connector. Follow the standard pinouts for a V.24 RJ-45 connection (see
‘QV24 Interface connections’ on page 273).
Aprisa XE User Manual
Protected Terminals | 185
MHSB Cabling
The two radios are interconnected as follows:
CAUTION: Do not connect Transmit to Receive or Receive to Transmit as this may damage the radio or the
MHSB switch.
Cables supplied with MHSB
The following cables are supplied with a MHSB terminal:
Ethernet interface: RJ-45 ports standard TIA-568A patch cables .
Alarm interface: RJ-45 ports standard TIA-568A patch cables.
RF ports: two QMA male patch cables are supplied.
MHSB Power Supply
See ‘DC Power Supply’ on page 37 and ‘AC Power Supply’ on page 40.
Aprisa XE User Manual
186 | Protected Terminals
Configuring the Radios for Protected Mode
The MHSB switch does not require any special software. However, the radios connected to the MHSB
switch must be configured to work with the MHSB switch. This sets the alarm outputs and inputs to
function in MHSB mode.
You must configure the interfaces of both radios connected to the MHSB switch identically. To perform
this, you can either connect directly to the radio or use the test mode of the MHSB switch.
MHSB Terminal IP Addresses
Before configuring the link, you must ensure that the two independent links have correctly configured IP
address details.
All four radios in the protected link must be on the same subnet.
Example of MHSB IP addressing
Aprisa XE User Manual
Protected Terminals | 187
Mounting the MHSB Radios and Switches
Once the IP addresses are correctly configured, it is important to connect the A and B radios' Ethernet and
Alarm ports correctly. In general, mount radio A above the MHSB switch and radio B below the MHSB
switch:
There is an Ethernet connection between any of the four Ethernet ports on each radio and the Ethernet
port on the Tributary switch. There is also a connection between radio A and radio B, which ensures
Ethernet traffic is maintained if a radio loses power.
The Ethernet port on the protection switch can be connected to an Ethernet hub or switch to allow
multiple connections.
Important: The management Ethernet capacity on each of the four radios in the protected terminal must
be identical for remote communications to work and there should only be one IP connection to the
management network (via the tributary switch Ethernet port).
Aprisa XE User Manual
188 | Protected Terminals
Configuring the Terminals for MHSB
It is recommended that you configure the local and remote A side first, then the local and remote B side.
Both the local A and B radios must be configured identically, and both the remote A and B radios must be
configured identically.
Tip: As illustrated below, you may find it helpful to have two browser sessions running simultaneously.
You can then easily see both the A and B sides of the protected link.
To configure MHSB operation:
1. Select Link > Maintenance > MHSB.
2. Enable MHSB mode.
3. Select whether the radio is A or B.
Ensure that the radio connected to the A side of the protection switch (normally above the MHSB
switch) is set to Radio A and the radio connected to the B side of the protection switch (normally
below the MHSB switch) is set to Radio B.
In the event of a power outage, the radios will switch over to the A side of the protection switch when
the power is restored. The A side is also the default active side.
4. When you have made your changes, click Apply to apply changes or Reset to restore the previous
configuration.
5. Repeat steps 2 to 4 for the other side of the protected link.
Aprisa XE User Manual
Protected Terminals | 189
Clearing MHSB Alarms
If a switchover event occurs, the OK LED on the front panel and on the Terminal status and menu bar in
SuperVisor changes to amber.
1. Select Clear Switched Alarm from the MHSB Command drop-down list.
2. Click Apply to apply changes or Reset to reset the page.
Note: When MHSB mode is enabled, external alarm input 2 is used by the protection system to carry
alarms from the protection switch to the radio. In MHSB mode, therefore, only external alarm input 1 is
available for user alarms.
Aprisa XE User Manual
190 | Protected Terminals
Hitless Space Diversity (HSD)
HSD provides hitless RF receive path protection and hot standby transmitter redundancy. It is typically
deployed for paths where high path availability is required.
An Aprisa XE hitless space diversity terminal comprises two radio terminals, radio A and radio B.
Radio A is the primary radio which is fitted with the interface cards and connects to antenna A.
Antenna A always carries the transmitted signal and the received signal for Radio A.
Radio B is the secondary radio the receiver of which connects to antenna B. The transmitter in this radio is
the standby transmitter.
In the event of a radio A active transmitter failure, radio B transmitter becomes active.
Antenna B only carries the received signal for Radio B. This antenna is physically separated on the tower
by a pre-determined distance from Antenna A.
As both radios have a receive path, traffic from the path with the best received bit error rate is routed to
the customer interfaces in radio A.
In an HSD terminal, a HSD Protection Switch Card (PSC) is always fitted in slot H in Radio A and a HSD
Protection Interface Card (PIC) is always fitted in slot H in Radio B. The PSC card has a card front switch
which controls the hardware setting of the HSD system Active Radio (Auto Select, Radio A or Radio B).
Customer interfaces are provided on radio A only in interface slots A to G. Interface connections to
Ethernet and the external alarm inputs and outputs are also provided on radio A only.
Aprisa XE User Manual
Protected Terminals | 191
HSD Terminal Cabling
The two HSD radios are interconnected as follows:
Cables Supplied with HSD Terminal
The following cables are supplied with a HSD terminal:
RF cable
A 110 mm QMA female to QMA female low loss RF cable is required to interconnect between the TX ports
of both radio A and radio B. This cable carries the radio B transmitter output to the radio A transmitter
switch.
Ethernet Cable
A 200 mm RJ45 to RJ45 Ethernet cable between the Ethernet ports of radio A and radio B. This cable
carries management IP traffic between radio A and radio B.
Traffic Cable
A 200 mm RJ45 to RJ45 Ethernet cable between the PSC and PIC. This cable carries all user traffic
between Radio A and Radio B.
Aprisa XE User Manual
192 | Protected Terminals
HSD Terminal IP Addresses
Each radio in the HSD link is assigned a unique IP address. All four radios in the HSD link must be on the
same subnet.
The IP address of the four terminals can only be changed by logging into the relevant radio A or radio B.
When the IP addresses have been setup, an ethernet connection to any of the four radios can access all
four radios in the HSD link. The usual ethernet connection is to the near end Radio A (see ‘IP Addressing of
Terminals’ on page 53).
Example of IP addressing
Aprisa XE User Manual
Protected Terminals | 193
Configuring HSD Terminals
To simplify the management and configuration of the HSD terminals, SuperVisor provides four windows
which display the parameters for all four radios, the local and remote, radios A and B. The HSD System
menu item displays the four windows.
When a parameter is changed in the four window mode, the relevant parameter is automatically changed
to the same setting on the corresponding radio e.g. if a radio A modulation type is changed, the radio B
modulation type is also changed to the same setting.
The Local and Remote menus continue to display the parameters for the local and remote radios for the
near end terminal logged into.
The majority of SuperVisor HSD System pages contain the same parameters and controls as the standard
1+0 XE terminal. The main exceptions are the HSD Control page and the HSD Performance Summary page.
Aprisa XE User Manual
194 | Protected Terminals
HSD Active Radio Control
The HSD system ‘Active Radio’ control determines if the selection of Radio A or Radio B is automatic or
manual. This controls both the radio transmitters and receivers.
The Active Radio can be set with the hardware switch on the PSC card front or with the SuperVisor
software control. The last change of hardware / software control determines the state of the HSD system.
The SuperVisor software control will always reflect the state of the HSD system.
After terminal startup or reboot, the state of the PSC mode switch determines the setting used by the
system and the SuperVisor software control is set to reflect the state of the HSD system.
The PSC card has two card front LEDs which indicate the status of the HSD system:
PSC Mode
Switch
Hardware Control Change
Software Control Change
LED A
LED B
LED A
LED B
Radio A
Solid Amber
Off
Flashing Amber
Off
Auto Select
Solid Green
Solid Green
Flashing Amber
Flashing Amber
Off
Solid Amber
Off
Flashing Amber
Radio B
To set the HSD controls:
1. Select HSD System > Maintenance > Control.
2. Set the Active Radio parameter.
Active Radio
Mode of Operation
Auto Select
(default)
Automatic mode:
The hitless receive will select traffic from the receive path of best
performance
The HSD system will switch to the standby transmitter if the active
transmitter fails (TX failure alarm)
Radio A Only
Manual selection of radio path A only for both the transmitter and
receiver i.e. no automatic switching
Radio B Only
Manual selection of radio path B only for both the transmitter and
receiver i.e. no automatic switching
Note: There is no timeout for a manual selection of the Active Radio setting (Radio A only or Radio B only)
but a ‘Mode Switch Software Override’ alarm will warn if the software has overwritten the PSC Mode
Switch.
Aprisa XE User Manual
Protected Terminals | 195
3. Set the Parameter Compare Checking.
Parameter Compare Checking
Option
On
(default)
Any mismatch in parameters shown in Terminal Settings
between Radio A and Radio B will generate a Parameter
Mismatch alarm.
Off
No Parameter Mismatch alarm will be generated.
To view the HSD System Performance Summary:
1. Select HSD System > Performance > Summary.
Field
Explanation
Terminal UCEs
The total number of HSD terminal uncorrectable blocks since the last
reset
Terminal Errored
seconds
The total number of HSD terminal operational seconds with errored
traffic since the last reset
Terminal Error free
seconds
The total number of HSD terminal error free operational seconds since
the last reset
Terminal BER
The system will report an estimated HSD terminal Bit Error Rate up to a
maximum of 1 in 1021
Active Transmitter
Dislays the current active transmitter (TxA or TxB)
Click Reset Counters to reset the error counters to zero.
Aprisa XE User Manual
In-Service Commissioning | 197
12. In-Service Commissioning
Before You Start
When you have finished installing the hardware, RF and the traffic interface cabling, the system is ready
to be commissioned. Commissioning the terminal is a simple process and consists of:
1. Powering up the terminals
2. Configuring both the local and remote terminals using SuperVisor
3. Aligning the antennas
4. Synchronizing the terminals
5. Testing the link is operating correctly. As a minimum, conduct the suggested tests to ensure correct
operation. More extensive testing may be required to satisfy the end client or regulatory body
requirements.
6. Connecting up the client or user interfaces
What You Will Need
Appropriately qualified commissioning staff at both ends of the link.
Safety equipment appropriate for the antenna location at both ends of the link.
Communication equipment, that is, mobile phones or two-way radios.
SuperVisor software running on an appropriate laptop, computer, or workstation at one end of the
link.
Tools to facilitate loosening and re-tightening the antenna pan and tilt adjusters.
Predicted receiver input levels and fade margin figures from the radio link budget (You can use
Surveyor (see ‘Path planning’ on page 23) to calculate the RSSI, fade margin, and availability).
Aprisa XE User Manual
198 | In-Service Commissioning
Applying Power to the Terminals
WARNING:
Before applying power to a terminal, ensure you have connected the safety
earth and antenna cable.
Apply power to the terminals at each end of the link.
When power is first applied, all the front panel LEDs will illuminate red for several seconds as the system
initializes.
After the system is initialized, the OK LED on the front panel should illuminate green and if the terminals
are correctly configured, the TX and RX LED should also be illuminated green.
If the RX LED is:
Red
the antennas are may be significantly mis-aligned with no signal being
received
Amber
the antennas may be roughly aligned with some signal being received
Green
the antennas are well-aligned and adequate signal is being received to create
a reliable path
If the TX LED is:
Red
the transmitter is faulty
Amber
there is a fault in the antenna connection or feeder cable
Green
the transmitter is working normally
Review the Link Configurations Using SuperVisor
1. Connect a PC, with SuperVisor installed, to both terminals in the link.
2. Log into the link.
3. Select Link > Summary and confirm the following basic information:
Terminal IP address(es)
Terminal TX and RX frequencies
RSSI (dBm)
TX power (dBm)
SNR (dBm)
Note: If the terminals have not already been configured, refer to ‘Configuring the terminal’ on page 69,
‘Configuring the traffic interfaces’ on page 91, and ‘Configuring the traffic cross connections’ on page
145.
Aprisa XE User Manual
In-Service Commissioning | 199
Antenna Alignment
For any point-to-point link, it is important to correctly align the antennas to maximize the signal strength
at both ends of the link. Each antenna must be pointing directly at the corresponding antenna at the
remote site, and they must both be on the same polarization. The antennas are aligned visually, and then
small adjustments are made while the link is operating to maximize the received signal.
Directional antennas have a radiation pattern that is most sensitive in front of the antenna, in line with
the main lobe of the radiation pattern. There are several other lobes (side lobes) that are not as sensitive
as the main lobe in front of the antenna.
For the link to operate reliably, it is important that the main lobes of both antennas are aligned. If any of
the side lobes are aligned to the opposite antenna, the received signal strength of both terminals will be
lower, which could result in fading. If in doubt, check the radiation patterns of the antennas you are
using.
Checking the Antenna Polarization
Check that the polarization of the antennas at each end of the link is the same.
Antenna polarization of grid antennas are normally indicated by an arrow or with ‘H’ and ‘V’ markers
(indicating horizontal and vertical).
On Yagi antennas, ensure the orientation of the elements are the same at each end of the link.
Transmit frequency and power, and antenna polarization would normally be defined by a regulatory body,
and typically licensed to a particular user. Refer to your license details when setting the antenna
polarization.
Aprisa XE User Manual
200 | In-Service Commissioning
Visually Aligning Antennas
1. Stand behind the antenna, and move it from side to side until it is pointing directly at the antenna at
the remote site. The remote antenna may be made more visible by using a mirror, strobe light, or
flag.
If the remote end of the link is not visible (due to smoke, haze, or local clutter, etc), align the
antenna by using a magnetic compass. Calculate the bearing using a scale map of the link path.
When setting the antenna on the desired bearing ensure that you use the appropriate true-north to
magnetic-north offset. Also ensure that the compass reading is not affected by standing too close to
metallic objects.
2. Once the antenna is pointing at the remote antenna, tighten the nuts on the U-bolt or antenna clamp
just enough to hold it in position. Leave the nuts loose enough so that small adjustments can still be
made. Check that the antenna is still pointing in the correct direction.
3. Move the antenna up or down until it is pointing directly at the remote site.
4. Tighten the elevation and azimuth adjustment clamps.
5. Mark the position of the antenna clamps so that the antenna can be returned to this rough aim point
easily when accurately aligning the antennas.
6. Repeat steps 1-5 at the opposite site.
Note: Low gain antennas need less adjustment in elevation as they are simply aimed at the horizon. They
should always be panned horizontally to find the peak signal.
Aprisa XE User Manual
In-Service Commissioning | 201
Accurately Aligning the Antennas
Once the antennas are visually aligned, accurately align both antennas by carefully making small
adjustments while monitoring the RSSI. This will give the best possible link performance.
Note: Remember that it is important to align the main radiation lobes of the two antennas to each other,
not any side lobes. It may be easier to perform this procedure if you can communicate with someone at
the remote site by telephone, mobile, or two-way radio.
1. Connect a laptop PC running SuperVisor software and power up the terminals at both ends of the link.
Select Link > Performance > Summary so that you can see the RSSI indication for the local terminal.
Alternatively, use the RSSI test point on the front panel together with a multimeter (see ‘Measuring
the RSSI’ on page 202).
2. Move the antenna through a complete sweep horizontally (known as a 'pan') either side of the point
established in the visual alignment process above. Note down the RSSI reading for all the peaks in RSSI
that you discover in the pan.
3. Move the antenna to the position corresponding to the maximum RSSI value obtained during the pan.
Move the antenna horizontally slightly to each side of this maximum to find the two points where the
RSSI drops slightly.
4. Move the antenna halfway between these two points and tighten the clamp.
5. If the antenna has an elevation adjustment, move the antenna through a complete sweep (known as a
'tilt') vertically either side of the point established in the visual alignment process above. Note down
the RSSI reading for all the peaks in RSSI that you discover in the tilt.
6. Move the antenna to the position corresponding to the maximum RSSI value obtained during the tilt.
Move the antenna slightly up and then down from the maximum to find the two points where the RSSI
drops slightly.
7. Move the antenna halfway between these two points and tighten the clamp.
8. Recheck the pan (steps 2-4) and tighten all the clamps firmly.
9. Perform steps 1-8 at the remote site.
Aprisa XE User Manual
202 | In-Service Commissioning
Measuring the RSSI
Measure the RSSI value with a multimeter connected to the RSSI test port on the front of the terminal (see
‘Front panel connections and indicators’ on page 31).
1. Insert the positive probe of the multimeter into the RSSI test port, and clip the negative probe to the
chassis of the terminal (earth).
2. Pan and tilt the antenna until you get the highest VDC reading. The values shown in the table below
relate the measured VDC to the actual received signal level in dBm regardless of bandwidth and
frequency.
RSSI test
port value
(VDC)
RSSI
reading
(dBm)
RSSI test
port value
(VDC)
RSSI
reading
(dBm)
RSSI test
port value
(VDC)
RSSI
reading
(dBm)
0.000
- 100
0.675
- 73
1.350
- 46
0.025
- 99
0.700
- 72
1.375
- 45
0.050
- 98
0.725
- 71
1.400
- 44
0.075
- 97
0.750
- 70
1.425
- 43
0.100
- 96
0.775
- 69
1.450
- 42
0.125
- 95
0.800
- 68
1.475
- 41
0.150
- 94
0.825
- 67
1.500
- 40
0.175
- 93
0.850
- 66
1.525
- 39
0.200
- 92
0.875
- 65
1.550
- 38
0.225
- 91
0.900
- 64
1.575
- 37
0.250
- 90
0.925
- 63
1.600
- 36
0.275
- 89
0.950
- 62
1.625
- 35
0.300
- 88
0.975
- 61
1.650
- 34
0.325
- 87
1.000
- 60
1.675
- 33
0.350
- 86
1.025
- 59
1.700
- 32
0.375
- 85
1.050
- 58
1.725
- 31
0.400
- 84
1.075
- 57
1.750
- 30
0.425
- 83
1.100
- 56
1.775
- 29
0.450
- 82
1.125
- 55
1.800
- 28
0.475
- 81
1.150
- 54
1.825
- 27
0.500
- 80
1.175
- 53
1.850
- 26
0.525
- 79
1.200
- 52
1.875
- 25
0.550
- 78
1.225
- 51
1.900
- 24
0.575
- 77
1.250
- 50
1.925
- 23
0.600
- 76
1.275
- 49
1.950
- 22
0.625
- 75
1.300
- 48
1.975
- 21
0.650
- 74
1.325
- 47
2.000
- 20
Aprisa XE User Manual
In-Service Commissioning | 203
Checking Performance
The amount of testing performed on the completed installation will depend on circumstances. Some
customers may need to prove to a local licensing regulatory body that the link complies with the license
provisions. This may require special telecommunications test equipment to complete these tests. Most
customers simply want to confirm that their data traffic is successfully passing over the link, or that the
customer interfaces comply with known quality standard.
However, the most important performance verification checks are:
Receive input level
Fade margin
Long-term BER
Checking the Receive Input Level
The received signal strength at the local terminal is affected by many components in the system and has a
direct relationship with the resulting performance of the link. A link operating with a lower than expected
signal strength is more likely to suffer from degraded performance during fading conditions. The receive
input level of a link is normally symmetrical (that is, similar at both ends).
1. Compare the final RSSI figure obtained after antenna alignment with that calculated for the link.
2. If the RSSI figure is in excess of 3 dB down on the predicted level, recheck and correct problems using
the table below and then recheck the RSSI. Alternatively, recheck the link budget calculations.
Possible cause
Terminal(s)
Is the terminal operating on the correct frequency?
Local & remote
Is the remote terminal transmit power correct?
Remote
Are all the coaxial connectors tight?
Local & remote
Is the antenna the correct type, that is, gain and frequency of operation?
Local & remote
Is the antenna polarized?
Local & remote
Is the antenna aligned?
Local & remote
Is the path between the terminals obstructed?
Note: If following the above steps does not resolve the situation, contact Customer Support for
assistance.
3. Record the RSSI figure on the commissioning form.
4. Repeat steps 1 to 2 for the other end of the link.
Aprisa XE User Manual
204 | In-Service Commissioning
Checking the Fade Margin
The fade margin is affected by many components in the system and is closely related to the received
signal strength. A link operating with a lower than expected fade margin is more likely to suffer from
degraded performance during fading conditions. A reduced fade margin can be due to operating the link
too close to the noise floor, or the presence of external interference. The fade margin of a link can be
asymmetrical (that is, different at each end).
Possible causes of low fade margin are as follows:
Problem
Terminal
Low receive signal strength (see above table)
Local and Remote
Interfering signals on the same, or very close to, the frequency of the
local terminal receiver.
Local
Intermodulation products that land on the same or very close to the
frequency of the local terminal receiver.
Local or Remote
Operating near the local receiver noise floor
Local
To check the fade margin:
1. Confirm (and correct if necessary) the receive input level (see the previous test).
Note: If the receive input level is lower than expected, the fade margin may also be low.
2. Select Link > Performance > Summary and check the current BER of the link in its normal condition is
better than 10-6 (If necessary, clear out any extraneous errors by clicking Reset Counters).
3. Check the signal to noise (S/N) indication on the Link > Performance > Summary page. This shows the
quality of the signal as it is being processed in the modem. It should typically be better than 30 dB. If
it is less than 25 dB, it means that either the RSSI is very low or in-band interference is degrading the
S/N performance.
4. Temporarily reduce the remote site's transmit power using either an external attenuator or SuperVisor
(Remote > Terminal > Basic).
Note: Ideally, the transmit power of the remote site should be reduced by up to 20 dB, which will
require the use of an external 50 ohm coaxial attenuator capable of handling the transmit power
involved. In the absence of an attenuator, reduce the transmit power using SuperVisor.
5. Check and note the current BER of the link in its now faded condition (Again, if necessary, clear out
any extraneous errors (introduced by the power reduction step above) by clicking Reset Counters).
6. Compare the unfaded and faded BER performance of the link (steps 2 and 4). Continue to reduce the
remote transmit power until either the BER drops to 10 -6 or the remote transmitter power has been
reduced by 20 dB.
Note: The fade margin of the link is expressed as a number (of dB) that the link can be faded
(transmitter power reduced) without reducing the BER below operating specifications (1 * 10-6 BER). A
20 dB fade margin is adequate for most links.
Aprisa XE User Manual
In-Service Commissioning | 205
7. Record the fade margin and SNR results on the commissioning form.
Note: If the transmit power is reduced using SuperVisor rather than an external attenuator, the fade
margin should be recorded as ‘Greater than x dB’ (where x = the power reduction).
8. Restore the remote terminal transmit power to normal.
9. Repeat steps 1 to 7 for the other end of the link.
Note: If following all the guidelines above does not resolve the situation, contact Customer Support
for assistance.
Checking the Long-Term BER
The BER test is a measure of the stability of the complete link. The BER results of a link can be
asymmetrical (that is, different at each end).
1. Select Link > Performance > Summary and check the current BER and error counters of the link. If
necessary, clear out any extraneous errors by selecting Reset Counters.
2. Wait 15 minutes, and check the BER display and error counters again. If there are a small number of
errors and the BER is still better than 1 x 10-9, continue the test for 24 hours. If there are a significant
number of errors, rectify the cause before completing the 24 hour test.
Note: It is normal to conduct the BER test in both directions at the same time, and it is important that
no further work be carried out on the equipment (including the antenna) during this period.
3. The BER after the 24 hour test should typically be better than 1 x 10-8.
4. Record the BER results on the commissioning form.
Bit Error Rate Tests
A Bit Error Rate (BER) test can be conducted on the bench, (see ‘Bench Setup’ on page 43).
Attach the BER tester to the interface port(s) of one terminal, and either another BER tester or a loopback
plug to the corresponding interface port of the other terminal.
This BER test can be carried out over the Ethernet, E1 / T1, V.24 or HSS interfaces. It will test the link
quality with regard to user payload data.
CAUTION: Do not apply signals greater than -20 dBm to the antenna as they can damage the receiver. In a
bench setup, there must be 60 - 80 dB at up to 2 GHz of 50 ohm coaxial attenuation (capable of handling
the transmit power) between the terminals’ antenna connectors.
Aprisa XE User Manual
206 | In-Service Commissioning
Additional Tests
Depending on license requirements or your particular needs, you may need to carry out additional tests,
such as those listed below.
Refer to the relevant test equipment manuals for test details.
Test
Test equipment required
TX power output measurements (at TX and
duplexer outputs)
Power meter
TX spectrum bandwidth
Spectrum analyzer
TX spectral purity or harmonic outputs
Spectrum analyzer
TX center frequency
Frequency counter or spectrum analyzer
Bulk capacity BER test
BER tester
LAN throughput or errors
LAN tester
G.703 / HDB3 waveforms
Digital oscilloscope
Serial interface BER
BER tester
Audio quality
PCM4 or SINAD test set
Aprisa XE User Manual
In-Service Commissioning | 207
Checking the Link Performance
For a graphical indication of the link performance, you can use the constellation analyzer.
The 'dots' are a graphical indication of the quality of the demodulated signal. Small dots that are close
together indicate a good signal. If the dots become spaced further apart, this indicates that the signal
quality is degrading. This signal quality degradation can be caused by low Rx signal level due to, for
example:
external interference
failure of any of the following: modem, receiver, far end transmitter, an antenna (either end), a
feeder or connector (for example, due to water damage)
path issues such as multipath fading or obstructions
To check the performance of the link using the constellation analyzer:
1. Select Link or Local or Remote > Performance > Constellation.
2. Click Start to start the constellation analyzer.
While the constellation analyzer is running, the terminal will temporarily stop collecting error
performance statistics. If you want to run the constellation analyzer anyway, click OK when you see
this warning message:
3. Click Stop to stop the constellation analyzer.
The terminal automatically resumes collecting error performance statistics.
Aprisa XE User Manual
208 | In-Service Commissioning
Viewing a Summary of the Link Performance
To view the performance summary for a terminal:
Select Link or Local or Remote > Performance > Summary.
Field
Explanation
Link Performance
Correctable errors
The total number of correctable blocks since the last reset
Uncorrectable errors
The total number of uncorrectable blocks since the last reset
SNR (dB)
The Signal to Noise Ratio of the link in dB
RSSI (dBm)
The Received Signal Strength Indication at the Rx input in dBm
Errored seconds
The total number of operational seconds with errored traffic since the
last reset
Error free seconds
The total number of error free operational seconds since the last reset
BER
The system will report an estimated Bit Error Rate up to a maximum of
1 in 1021
TX temperature
The measured temperature in the transmitter module in °C
RX temperature
The measured temperature in the receiver module in °C
Ethernet performance
Transmitted packets
The total number of transmitted Ethernet packets
Received packets
The total number of received Ethernet packets
Received packet errors
The total number of packets received with errors
Click Reset Counters to reset the error counters to zero.
Aprisa XE User Manual
In-Service Commissioning | 209
Saving the History of the Link Performance
Link performance history data is stored in a rolling buffer which can be saved as a *.cvs file (default
filename is savedPerformanceHistory.csv). The maximum history data buffer is 1 week of 1 hour records
and the last hour is displayed in minute records.
The parameters saved are:
Date / Time
SNR (minimum over period)
SNR (average over period)
SNR (maximum over period)
RSSI (minimum over period)
RSSI (average over period)
RSSI (maximum over period)
BER (value at end of period)
UCEs count (value at end of period)
Transmitter temperature (value at end of period)
To save the history of the link performance for a terminal:
Select Local > Performance > Save History.
Example of file (simulated fade data):
PREVIOUS WEEK
TIME
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
…
6 09:44:50 2009
6 10:44:50 2009
6 11:44:50 2009
6 12:44:51 2009
6 13:44:51 2009
6 14:44:51 2009
SNR min
(dB)
35.14
35.14
35.14
15.31
22.52
16.20
SNR avg
(dB)
35.26
35.26
35.26
25.77
22.75
26.05
SNR max
(dB)
35.39
35.40
35.40
58.54
22.89
54.61
RSSI min
(dBm)
-54.00
-54.00
-54.00
-114.00
-84.10
-87.10
RSSI avg RSSI max
(dBm)
(dBm)
-54.00
-54.00
-53.90
-53.90
-53.90
-53.90
-77.00
-54.00
-83.70
-83.60
-77.40
-60.20
SNR min
(dB)
22.52
22.55
22.50
22.50
22.54
22.52
22.48
22.49
22.48
22.50
22.61
22.46
22.46
22.47
22.48
22.49
16.20
16.23
35.10
35.08
35.07
35.06
35.06
35.09
35.07
SNR avg
(dB)
28.38
25.67
23.52
24.35
22.73
26.67
30.19
28.87
30.65
29.99
29.78
25.70
26.96
24.71
30.19
25.97
22.94
26.84
40.60
39.17
36.63
36.68
35.34
36.28
42.56
SNR max
(dB)
22.75
22.75
22.75
22.78
22.77
22.75
22.79
22.74
22.74
22.75
22.76
22.74
22.75
22.75
22.73
22.75
54.61
49.90
35.24
35.28
35.26
35.24
35.25
35.24
35.28
RSSI min
(dBm)
-84.10
-84.10
-84.10
-84.10
-84.10
-84.10
-84.10
-84.10
-84.10
-84.00
-84.00
-84.10
-84.10
-84.10
-84.10
-84.20
-87.10
-87.00
-60.50
-60.50
-60.50
-60.60
-60.60
-60.50
-60.60
RSSI avg RSSI max
(dBm)
(dBm)
-78.19
-83.80
-80.89
-83.80
-83.07
-83.70
-82.23
-83.70
-83.86
-83.80
-79.90
-83.80
-76.38
-83.70
-77.68
-83.80
-75.94
-83.80
-76.59
-83.80
-76.82
-83.80
-80.86
-83.90
-79.61
-83.80
-81.86
-83.80
-76.36
-83.80
-80.61
-83.80
-83.76
-83.90
-73.31
-60.30
-54.96
-60.30
-56.40
-60.30
-58.95
-60.20
-58.90
-60.30
-60.24
-60.30
-59.28
-60.30
-53.03
-60.30
BER
3.40E-12
3.39E-12
3.38E-12
1.58E-05
6.92E-06
9.67E-05
UCEs
144
144
144
1045
9912
72125
Tx Temp
(deg C)
50
50
50
50
51
52
PREVIOUS HOUR
TIME
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
Mon Apr
…
6 14:11:51 2009
6 14:12:51 2009
6 14:13:51 2009
6 14:14:51 2009
6 14:15:51 2009
6 14:16:51 2009
6 14:17:51 2009
6 14:18:51 2009
6 14:19:51 2009
6 14:20:51 2009
6 14:21:51 2009
6 14:22:51 2009
6 14:23:51 2009
6 14:24:51 2009
6 14:25:51 2009
6 14:26:51 2009
6 14:27:51 2009
6 14:28:51 2009
6 14:29:51 2009
6 14:30:51 2009
6 14:31:51 2009
6 14:32:51 2009
6 14:33:51 2009
6 14:34:51 2009
6 14:35:51 2009
Aprisa XE User Manual
BER
5.89E-06
5.86E-06
5.84E-06
5.81E-06
5.78E-06
5.75E-06
5.73E-06
5.71E-06
5.68E-06
5.66E-06
5.64E-06
5.62E-06
5.59E-06
5.57E-06
5.55E-06
5.53E-06
7.30E-06
6.67E-03
1.70E-03
9.13E-04
6.11E-04
4.52E-04
3.56E-04
2.92E-04
2.46E-04
UCEs
22821
23369
23847
24338
24855
25374
25918
26473
27007
27561
28167
28717
29237
29776
30368
30942
71751
72125
72125
72125
72125
72125
72125
72125
72125
Tx Temp
(deg C)
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
52
210 | In-Service Commissioning
To save the alarm history from the Remote terminal, login to the Remote terminal and Select Local >
Alarms > Save History.
Aprisa XE User Manual
RSSI avg (dBm)
Select Link or Local or Remote > Performance > Clear History.
Aprisa XE User Manual
0.00
-10.00
-20.00
-30.00
-40.00
-50.00
-60.00
-70.00
To clear the history of the link performance for a terminal:
-80.00
-90.00
Date / Time
Mon Apr 6 14:26:51 2009
Mon Apr 6 14:27:51 2009
Mon Apr 6 14:28:51 2009
Mon Apr 6 14:29:51 2009
Mon Apr 6 14:30:51 2009
Mon Apr 6 14:31:51 2009
Mon Apr 6 14:32:51 2009
Mon Apr 6 14:33:51 2009
Mon Apr 6 14:34:51 2009
Mon Apr 6 14:35:51 2009
Mon Apr 6 14:27:51 2009
Mon Apr 6 14:28:51 2009
Mon Apr 6 14:29:51 2009
Mon Apr 6 14:30:51 2009
Mon Apr 6 14:31:51 2009
Mon Apr 6 14:32:51 2009
Mon Apr 6 14:33:51 2009
Mon Apr 6 14:34:51 2009
Mon Apr 6 14:35:51 2009
Mon Apr 6 14:24:51 2009
Mon Apr 6 14:23:51 2009
Mon Apr 6 14:22:51 2009
Mon Apr 6 14:21:51 2009
Mon Apr 6 14:20:51 2009
Mon Apr 6 14:19:51 2009
Mon Apr 6 14:18:51 2009
Mon Apr 6 14:26:51 2009
Date / Time
Mon Apr 6 14:25:51 2009
Aprisa XE Link Performance
Mon Apr 6 14:25:51 2009
Mon Apr 6 14:24:51 2009
Mon Apr 6 14:23:51 2009
Mon Apr 6 14:22:51 2009
Mon Apr 6 14:21:51 2009
Mon Apr 6 14:20:51 2009
Mon Apr 6 14:19:51 2009
Mon Apr 6 14:18:51 2009
Mon Apr 6 14:17:51 2009
Mon Apr 6 14:16:51 2009
Mon Apr 6 14:15:51 2009
Mon Apr 6 14:14:51 2009
Mon Apr 6 14:13:51 2009
Mon Apr 6 14:12:51 2009
Mon Apr 6 14:11:51 2009
Graph of Date / Time vs the average RSSI
Mon Apr 6 14:17:51 2009
Mon Apr 6 14:16:51 2009
Mon Apr 6 14:15:51 2009
Mon Apr 6 14:14:51 2009
Mon Apr 6 14:13:51 2009
Mon Apr 6 14:12:51 2009
Mon Apr 6 14:11:51 2009
SNR avg (dB)
In-Service Commissioning | 211
To create an Excel chart of the link performance for a terminal:
1. Open the *.csv file with Excel.
2. Select the ‘Time’ column and the column you wish to graph e.g. ‘SNR avg (dB)’ or ‘RSSI avg (dBm)’
3. Select ‘Insert Chart’ from the Excel menu.
Graph of Date / Time vs the average SNR
Aprisa XE Link Performance
45.00
40.00
35.00
30.00
25.00
20.00
15.00
10.00
5.00
0.00
Maintenance | 213
13. Maintenance
There are no user-serviceable components within the terminal.
All hardware maintenance must be completed by 4RF or an authorized service centre.
Do not attempt to carry out repairs to any boards or parts.
Return all faulty terminals to 4RF or an authorized service centre.
For more information on maintenance and training, please contact Customer Services.
CAUTION: Electro Static Discharge (ESD) can damage or destroy the sensitive electrical components in the
terminal.
Routine Maintenance
Every six or twelve months, for both ends of the link, you should record the RSSI and SNR levels as well as
checking the following:
Item
What to check or look for
Equipment shelter environment
Water leaks
Room temperature
Excessive vibration
Vermin damage
Terminal mounting
Firmly mounted
Antenna cable connections
Tight and dry
Antenna cable and its supports
Not loose or suffering from ultra-violet degradation
Antenna and its mounting hardware
Not loose, rusty or damaged
Safety earth
Connections tight
Cabling intact
DC system
Connections tight
Voltage in normal limits
Batteries (if installed)
Connections tight
Electrolyte levels normal
Aprisa XE User Manual
214 | Maintenance
Terminal Upgrades
You can upgrade all software for both terminals remotely (through a management network), which
eliminates the need to physically visit either end of the link.
A terminal is upgraded by accessing a running TFTP server (see ‘TFTP Upgrade Process’ on page 221). All
the required files are uploaded from the TFTP server into the terminal and then activated following a
terminal reboot.
System files can be manually uploaded (see ‘Uploading System Files’ on page 226‘).
Inventory File
Software release 8.2.10 and all future software releases, contains an inventory file (similar to a manifest
file) which is used to validate the software files in the terminal.
To view the Software Status of the terminal:
Select Link, Local or Remote > Summary
Software status
Function
Standard Software
Release
The software status indicates ‘Standard Software Release’ if the
following system software files have not been changed since the last
TFTP Upgrade.
Kernel image file
Software image file
Firmware image files
Configuration files
Modified Software
Release
The software status indicates ‘Modified Software Release’ if the system
software files have been changed since the last TFTP Upgrade.
This could be caused by:
an image file which has been uploaded to the terminal since the
last TFTP upgrade which is not part of that upgrade.
an image file which was part of the last TFTP upgrade but was
subsequently deleted.
Upgrade Prerequisites
To minimize disruption of link traffic and prevent your terminals from being rendered inoperative, please
follow the procedures described in this section together with any additional information or instructions
supplied with the upgrade package.
Before upgrading the terminal, ensure that you have saved the configuration file (see ‘Saving the
terminal's configuration’ on page 89) as well as the cross connection configuration (see ‘Saving cross
connection configurations’ on page 155).
The Remote terminal upgrade process will be faster if the bandwidth allocated to the management
ethernet capacity is maximized.
The terminal software must be identical at both ends of the link.
At the end of the terminal upgrade process, the versions of image files (kernel software, and firmware)
that were in use before the upgrade are still in the terminal. You can restore them, if required, by editing
the image tables and reactivating the old files (see ‘Changing the Status of an Image ’ on page 232).
IMPORTANT NOTE: Ensure you are logged into the Near end terminal as Admin before you start an
upgrade.
Aprisa XE User Manual
Maintenance | 215
Software Upgrade Process
Unzip and save the following folders to your hard drive:
8.6.77 Software
tftpd32.exe
The following steps are required for the software upgrade process:
1. Identify the correct TFTP upgrade type (see ‘Identifying the Correct TFTP Upgrade Type’ on page
217).
2. If the terminals are operating software prior to 8.3.40:
Upload the Root File System (see ‘Uploading the Root File System’ on page 216)
Upload the Motherboard Images (see ‘Uploading the Motherboard Images’ on page 216).
Reboot the terminal.
3. Go through the steps of the TFTP upgrade process (see ‘TFTP Upgrade Process’ on page 221).
4. Upgrade for new FXO/FXS and modem images
5. Reboot the terminal.
6. Clear the Java and web browser caches (see ‘Step 7: Clear the Java and web browser caches’ on
page 223).
If the TFTP upload process fails, an ‘Upload Fail’ alarm is raised. If the TFTP upload process fails due to a
power failure, the alarm is raised upon power recovery.
Aprisa XE User Manual
216 | Maintenance
Uploading the Root File System
Note: Uploading of image files can only be performed to the local terminal i.e. not via the link to the
remote terminal.
1. Logon to the local terminal as admin.
2. Go to SuperVisor > Local > Maintenance > Upload > Software.
3. Browse to the 8.6.77 Software folder and select ‘C-CC-R-8_6_7.img’.
4. Click Upload and wait for the upload status to display Succeeded.
5. Activate the ‘C-CC-R-8_6_7.img’ with SuperVisor Local > Maintenance > Image Table (see ‘Changing
the Status of an Image File’ on page 232).
Uploading the Motherboard Images
The E1 and E2 motherboard images do not update as part of the TFTP upgrade.
Check if the correct motherboard images are loaded with SuperVisor Local > Maintenance > Image Table.
Example: Radio on V8.4.60 with a Rev C motherboard.
The Motherboard Firmware images for this software version are:
Motherboard Type
Image Files Required
Rev C
C-fpga_E1-0-7-0.img
C-fpga_E2-0-5-3.img
(Motherboard 1
(Motherboard 2)
Rev D
C-fpga_E1-1-7-3.img
C-fpga_E2-1-5-4.img
(Motherboard 1
(Motherboard 2)
If the motherboard image files are not correct, upload the relevant image files.
Note: Uploading of image files can only be performed to the local terminal i.e. not via the link to the
remote terminal.
1. Logon to the local terminal as admin
2. Go to SuperVisor > Local > Maintenance > Upload > Firmware.
3. Browse to the 8.6.77 Software folder and select ‘C-fpga_Ex-x-x-x.img’.
4. Click Upload and wait for the upload status to display Succeeded.
5. Activate the ‘C-fpga_Ex-x-x-x.img’ with SuperVisor Local > Maintenance > Image Table (see ‘Changing
the Status of an Image File’ on page 232).
Aprisa XE User Manual
Maintenance | 217
Identifying the Correct TFTP Upgrade Type
The correct TFTP upgrade type will depend on both the Bootloader Version and the Software Version
Type.
Aprisa XE terminals running the older bootloader software (bootloader version 0) have a limitation on the
number of software images that can be loaded simultaneously into a terminal.
Identifying the Bootloader Version
Determine which bootloader version your terminal is running by using the SuperVisor menu item
Maintenance > Support Summary and look for the ‘Bootloader Version’ number:
(1)
If your terminal is running bootloader version 1 or greater, use the TFTP full upgrade process.
(2)
If your terminal is running bootloader version 0 and running a software version prior to 7.0.6,
use the TFTP partial upgrade process.
(3)
If your terminal is running bootloader version 0 and running a software version 7.0.6 or later,
use the TFTP standard upgrade process.
(4)
HSD terminals cannot run with bootloader version 0.
Aprisa XE User Manual
218 | Maintenance
Identifying the Software Version Type
There are six different software version types; ETSI type 1, ETSI type 1 HSD, ETSI type 2, ETSI type 2 HSD,
FCC Part 101 and FCC Part 90.
To determine which Software Version Type is currently installed on the terminal, take note of the
‘Software Version’ on SuperVisor Summary page. The last three characters indicate the Software Version
Type.
ETSI Compliance Body
8_6_77_E0
The E0 variant supports ETSI (Type 1) 1+0 and MHSB terminals with the same
variants as Aprisa XE software version 8.4.40.
8_6_77_E1
The E1 variant supports ETSI (Type 2) 1+0 and MHSB terminals with the same
variants as Aprisa XE software version 8.4.40 except for the 400 MHz 25 kHz
and 50 kHz which has been replaced with 900 MHz 25 kHz and 50 kHz.
8_6_77_E0h
The E0h variant supports ETSI (Type 1) Hitless Space Diversity (HSD)
terminals with the same variants as Aprisa XE software version 8.4.40.
8_6_77_E1h
The E1 variant supports ETSI (Type 2) Hitless Space Diversity (HSD) terminals
with the same variants as Aprisa XE software version 8.4.40 except for the
400 MHz 25 kHz and 50 kHz which has been replaced with 900 MHz 25 kHz
and 50 kHz.
FCC Compliance Body
8_6_77_F0
The F0 variant supports FCC part 90 1+0 and MHSB terminals.
8_6_77_F0h
The F0h variant supports FCC part 90 Hitless Space Diversity (HSD)
terminals.
8_6_77_F1
The F1 variant supports FCC part 101 1+0 and MHSB terminals.
8_6_77_F1h
The F1h variant supports FCC part 101 Hitless Space Diversity (HSD)
terminals.
Aprisa XE User Manual
Maintenance | 219
Upgrade Version Files
The following table defines the purpose of the upgrade version files:
Upgrade Version File
Upgrade Type
Software Version Type
8_6_77_E0a
Full TFTP upgrade
ETSI TYPE 1
8_6_77_E0
Standard TFTP upgrade
ETSI TYPE 1
8_6_77_E0h
Standard TFTP upgrade
ETSI TYPE 1 HSD
8_6_77_E0p
Partial TFTP upgrade
ETSI TYPE 1
8_6_77_E1a
Full TFTP upgrade
ETSI TYPE 2
8_6_77_E1
Standard TFTP upgrade
ETSI TYPE 2
8_6_77_E1h
Standard TFTP upgrade
ETSI TYPE 2 HSD
8_6_77_E1p
Partial TFTP upgrade
ETSI TYPE 2
8_6_77_F0a
Full TFTP upgrade
FCC Part 90
8_6_77_F0
Standard TFTP upgrade
FCC Part 90
8_6_77_F1a
Full TFTP upgrade
FCC Part 101
8_6_77_F1
Standard TFTP upgrade
FCC Part 101
Installing RF Synthesizer Configuration Files
If you are upgrading from a software version prior to 7_1_x, you will need to install new RF synthesizer
files, refer to ‘Configuration Files’ on page 226.
You can then upgrade the terminal using TFTP (see page 221).
Frequency Band
Synthesizer File(to be installed)
Comments
300, 400 MHz
XE_300_400_type_1_synth.cfg
BB synthesizer
300, 400 MHz
XE_300_400_type_2_synth.cfg
E3 synthesizer
300, 400 MHz
XE_300_400_type_3_synth.cfg
5 kHz sythesizer step
600, 700, 800, 900 MHz
XE_600_700_800_900_synth.cfg
1400 MHz
XE_1400_synth.cfg
1400 MHz
XE_1400TCVR_synth.cfg
1800 MHz
XE_1800_synth.cfg
2000, 2500 MHz
XE_2000_2500_synth.cfg
Aprisa XE User Manual
New transceiver (introduced
April 2012)
220 | Maintenance
TFTP Upgrade Process Types
TFTP partial upgrade process
Run the TFTP upgrade process by typing 8_6_77_E0p in the Upgrade Version field.
This will perform a partial upgrade which will delete unnecessary image files that might be taking up
space in the Image Table (which could prevent a standard upgrade succeeding).
Reboot the terminal.
Run a TFTP standard upgrade process on the terminal.
Reboot the terminal again.
TFTP standard upgrade process
This TFTP standard upgrade process excludes FPGA images for the newly introduced revisions of the
Modem, DFXO and DFXS cards.
Run the TFTP upgrade process by typing ‘8_6_77_E0’ in the Upgrade Version field.
If the standard upgrade fails, it may be necessary to make space for the new images by manually deleting
‘Inactive’ firmware image files.
To delete a firmware image file, select the SuperVisor menu item Maintenance > Image Table, select the
firmware image and click on Edit. Set the IMAGE DETAILS Command to ‘Delete’ and click ‘Apply’.
Reboot the terminal.
Additional TFTP upgrade options have been provided to load the new images separately. Run the TFTP
upgrade process using the file:
‘F1_8_6_7’ to load images for the newest DFXO and DFXS cards (rev D).
‘F2_8_6_7’ to load images for all revisions of DFXO and DFXS cards.
‘F3_8_6_7’ to load images for the newest Modem card (rev D).
Reboot the terminal again.
TFTP full upgrade process
Run the TFTP upgrade process for 1+0 and MHSB terminals by typing ‘8_6_77_E0a’ in the Upgrade Version
field.
Run the TFTP upgrade process for HSD terminals by typing ‘8_6_77_E0h’ in the Upgrade Version field.
Reboot the terminal.
Aprisa XE User Manual
Maintenance | 221
TFTP Upgrade Process
To upgrade a terminal using the TFTP:
1. Run the TFTP server.
2. Login to the Near end terminal / local terminal (see ‘IP Addressing of Terminals’ on page 53).
3. Run the TFTP upgrade process on the Remote terminal.
4. Reboot the Remote terminal.
5. Run the TFTP upgrade process on the Local terminal.
6. Reboot the Local terminal.
7. Clear the Java and web browser caches.
Step 1: Run the TFTP server
1. Double-click tftpd32.exe (located in the TFTPD directory) from the Aprisa CD supplied with the
product. Leave the TFTPD32 application running until the end of the upgrade process.
2. Click Settings and make sure that both SNTP server and DHCP server are not selected (no tick), and
click OK.
3. Click Browse and navigate to the root directory on the Aprisa CD (for example, D:\) supplied with the
product, then click OK.
4. Note down the IP address of the TFTP server (shown in the Server Interfaces drop-down list in the
TFTPD32 window) as you will need it later.
Aprisa XE User Manual
222 | Maintenance
Step 2: Log into the Local terminal
Use SuperVisor to log into the Near end terminal (now the Local terminal) (see ‘IP Addressing of
Terminals’ on page 53) with either 'modify' or 'admin' privileges.
Step 3: Run the TFTP upgrade process on the Remote terminal
1. Select Remote > Maintenance > Upload > TFTP Upgrade.
2. Enter the IP address of the TFTP server.
3. Enter the version number of the software that you are upgrading to as a three digit number separated
by underscores, for example, 8_6_77_E0 for ETSI variants.
4. Click Apply and check the TFTP server for download activity.
The Upgrade Result changes from 'Executing' to either 'Succeeded' or 'Failed'.
Note: This may take several minutes when upgrading the remote terminal.
If the upgrade has failed:
The TFTP server IP address may be set incorrectly
The 'Current Directory' on the TFTP server was not pointing to the location of the upload config file
e.g. 'Rel_8_6_77_E0.cfg' .
There may not be enough free space in the image table to write the file. Inactive images can be
deleted (and the terminal rebooted) to free up space for the new image (see ‘Changing the Status
of an Image File’ on page 232).
Step 4: Reboot the Remote terminal
Reboot the remote terminal before proceeding with the next step of the upgrade process (see ‘Rebooting
the Terminal’ on page 233).
1. Select Remote > Maintenance > Reboot and select [Hard Reboot]
Communications to SuperVisor remote page will fail until the remote terminal reboot has completed.
Aprisa XE User Manual
Maintenance | 223
Step 5: Run the TFTP upgrade process on the Local terminal.
1. Select Local > Maintenance > Upload > TFTP Upgrade.
2. Enter the IP address of the TFTP server (that you noted earlier)
3. Enter the version number of the software (that you are upgrading to) for example, 8_6_77_E0.
4. Click Apply and check the TFTP server for download activity.
The Upgrade Result changes from 'Executing' to either 'Succeeded' or 'Failed'.
Note: This may take several minutes when upgrading the remote terminal.
Step 6: Reboot the Local terminal
Reboot the local terminal before proceeding with the next step of the upgrade process (see ‘Rebooting
the Terminal’ on page 233).
1. Select Local > Maintenance > Reboot and select [Hard Reboot]
2. Log back into the Local terminal when the reboot has completed.
Step 7: Clear the Java and web browser caches
After upgrading the terminal you should clear the Java and web browser caches. The files stored in them
may cause the SuperVisor and Cross Connections applications to display incorrectly.
To clear the Java cache (Windows XP, Java 1.6):
1. Select Start > Control Panel.
2. Select Java
3. Click the General tab.
4. In the ‘Temporary Internet Files’, click Settings
5. Click on ‘Delete Files’ (‘Applications and Applets’ and ‘Trace and Log Files’ both ticked) and OK to
confirm.
Aprisa XE User Manual
224 | Maintenance
To clear your web browser cache (Mozilla Firefox 1.x and above):
1. Select Tools > Options.
2. Select Privacy and then click Cache.
3. Click Clear to clear the cache, and then click OK to confirm.
Aprisa XE User Manual
Maintenance | 225
To clear your web browser cache (Internet Explorer 7.0 and above):
1. Select Tools > Internet Options.
2. On the General tab
3. In Browsing history, click Delete
4. In the ‘Temporary Internet Files’, click Delete Files and Yes to confirm.
Aprisa XE User Manual
226 | Maintenance
Uploading System Files
System files e.g. configuration files, kernel image files, software image files and firmware image files can
be uploaded manually.
Note: You should only upgrade components that need changing. It is not always necessary, for instance, to
replace kernel or software files when upgrading a single firmware file. If interdependency exists between
file types, this will be made clear in the documentation that accompanied the update package.
Configuration Files
Configuration files (.cfg) are compressed archives containing a script to instruct the terminal on how to
handle the other files in the archive.
Uploading of configuration files can only be performed to the Local Terminal (not via the link to the
Remote Terminal).
RF synthesizer configuration files
The RF synthesizer configuration archive contains files that provide values for the transmitter and receiver
synthesizers to operate across the supported frequency bands.
Synthesizer configuration filenames have the following format:
XE_(frequency bands)_synth.cfg
e.g. XE_300_400_synth.cfg
Modem configuration files
The Modem configuration archive contains files that provide values for the Modem to operate at the
various supported channel sizes and modulation types.
Modem configuration filenames have the following format:
modem_(version number).cfg
e.g. modem_8_3_1.cfg (ETSI variants)
Cross-connect configuration files
The Cross-connect configuration archive contains the Cross Connections application program that can be
launched from within SuperVisor.
Cross-connect configuration filenames have the following format:
C-crossconnect_(version number).cfg
e.g. C-crossconnect_8_6_7.cfg
Aprisa XE User Manual
Maintenance | 227
To upload a configuration file:
1. Select Local > Maintenance > Config Files > Upload Configuration
2. Browse to the location of the file required to be uploaded into the terminal *.cfg.
3. Click on Upload.
The normal response is Succeeded if the file has been loaded correctly.
A response of ‘Failed’ could be caused by:
Not enough temporary space in the filesystem to uncompress the archive and execute the script
A file or directory expected by the script not being present on the filesystem
4. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233).
Aprisa XE User Manual
228 | Maintenance
Image Files
Image files (.img) are loaded into the terminal and either contains code that is executed by the system
processor, or contain instructions to configure the various programmable logic elements. The image file
types that can be uploaded are:
Kernel image files
Software image files
Firmware image files
Note: The Bootloader image file C-CC-B-(version number).srec and Flash File System image file C-CC-F(version number).img can only be changed in the factory.
Uploading of image files can only be performed to the local terminal (not via the link to the remote
terminal).
To upload and activate an image file:
1. Upload the required image file.
If the Upload Status page show ‘executing’, then ‘writing to flash’, then ‘Succeeded’, then the file has
been written into the image table correctly.
If the Upload Status is ‘Failed’, there may not be enough free space in the image table to write the
file. Inactive images can be deleted (and the terminal rebooted) to free up space for the new image
(see ‘Changing the Status of an Image File’ on page 232).
2. Set the status of the image to ‘activate’ (see ‘Changing the Status of an Image ’ on page 232).
This actually sets the status to ‘Selected’ until after a terminal reboot.
3. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233).
This activates the selected image. The image table status will now show ‘Active’.
The previous image file status will now show as ‘Inactive’.
Aprisa XE User Manual
Maintenance | 229
Kernel image files
Kernel image files contain code that forms the basis of the microprocessor’s operating system. There can
only ever be two kernel image files in the image table, the active and the inactive.
Kernel filenames have the following format:
C-CC-K-(version number).img
e.g. C-CC-K-6_0_0.img
To upload a kernel image file;
1. Select Local > Maintenance > Upload > Kernel
2. Browse to the location of the file required to be uploaded into the terminal *.img.
3. Click on Upload.
4. Activate the image (see ‘Changing the Status of an Image File’ on page 232).
5. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233).
Software image files
Software image files contain code that forms the basis of the terminal’s application and management
software (including the Web-based GUI). There can only ever be two software image files in the image
table, the active and the inactive.
Software image filenames have the following format:
C-CC-R-(version number).img
e.g. C-CC-R-8_6_7.img
To upload a software image file;
1. Select Local > Maintenance > Upload > Software
2. Browse to the location of the file required to be uploaded into the terminal *.img.
3. Click on Upload.
Software image files may take one or two minutes to upload as they can be quite large (≈ 2 Mbytes). The
size of this file has caused some Microsoft Internet Explorer proxy server setups to abort during the
software update process. To avoid this problem, either set the proxy file size limit to 'unlimited' or avoid
the use of the proxy altogether.
4. Activate the image (see ‘Changing the Status of an Image File’ on page 232).
5. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233).
Aprisa XE User Manual
230 | Maintenance
Firmware image files
Firmware image files contain instructions to configure the various programmable logic elements in the
terminal. There can only ever be two firmware image files for the same HSC version in the image table,
the active and the inactive.
Firmware image filenames have the following format:
C-fpga_ff-x-y-z.img
e.g. C-fpga_E5-0-7-3.img
where ff indicates the function (motherboard, interface card, etc).
Function Number
Function
E1
Motherboard 1
E2
Motherboard 2
E5
QJET Interface Card
E7
Q4EM Interface Card
E8
DFXO Interface Card
E9
DFXS Interface Card
EA
Modem
EB
QV24 Interface Card
EC
HSS Interface Card
ED
PSC (component of HSD system)
EE
PIC (component of HSD system)
FA
HSD modem
FB
QV24 Sync Interface Card
where x indicates the HSC (hardware software compatibility) version.
where y indicates the firmware major revision number
where z indicates the firmware minor revision number
To upload a firmware image file;
1. Select Local > Maintenance > Upload > Firmware
2. Browse to the location of the file required to be uploaded into the terminal *.img.
3. Click on Upload.
4. Activate the image (see ‘Changing the Status of an Image File’ on page 232).
5. Reboot the terminal using a ‘Hard Reboot’ (see ‘Rebooting the Terminal’ on page 233).
Aprisa XE User Manual
Maintenance | 231
Viewing the Image Table
To view the image table:
1. Select Link or Local or Remote > Maintenance > Image Table.
The image table shows the following information:
Heading
Function
Index
A reference number for the image file
Type
The image type ‘Kernel’, ‘Software’ or ‘Firmware’.
Status
The status of the image; 'Active', 'Inactive', ‘Selected’, ‘Current (deselected)’
Image Size
The image file size in bytes
Version
The image file name and version details
Note: Configuration file details do not appear in the image table.
Aprisa XE User Manual
232 | Maintenance
Changing the Status of an Image File
To change the status of an image:
1. Select Link or Local or Remote > Maintenance > Image Table.
2. Select the image you wish to change and click Edit.
3. On the Image Details, select the status from the Command drop-down list and click Apply.
Status
Function
Active
The image is currently being used by the system.
Inactive
The image is not currently being used by the system and could be
deleted.
Selected
The image is not currently being used by the system but has been
activated and will become active following a terminal reboot.
Current (deselected)
The image is currently being used by the system but as another image
has been selected, it will become inactive following a terminal reboot.
Aprisa XE User Manual
Maintenance | 233
Rebooting the Terminal
The local or remote terminals can be rebooted by SuperVisor.
You can specify a ‘Soft Reboot’ which reboots the terminal without affecting traffic or a ‘Hard Reboot’
which reboots the terminal (similar to power cycling the terminal).
You can specify an immediate reboot or setup a reboot to occur at a predetermined time.
To reboot the terminal:
1. Select Link or Local or Remote > Maintenance > Reboot.
2. Select the Reboot Type field:
Reboot Type
Function
None
Does nothing.
Soft Reboot
Reboots the software but does not affect customer traffic.
Hard Reboot
Reboots the entire terminal and affects customer traffic.
This reboot is similar cycling the power off and on.
3. Select the Reboot Command field:
Reboot Command
Function
None
Does nothing
Reboot Now
Execute the selected reboot now
Timed Reboot
Set the Reboot Time field to execute the selected reboot at a later date
and time.
This feature can be used to schedule the resulting traffic outage for a
time that has least customer impact.
Cancel Reboot
Cancel a timed reboot.
4. Click Apply to execute the reboot or Reset to restore the previous configuration.
Aprisa XE User Manual
234 | Maintenance
Support Summary
The support summary page lists key information about the terminal, for example, serial numbers,
software version, frequencies and so on.
To view the support summary:
Select Link or Local or Remote > Maintenance > Support Summary.
Aprisa XE User Manual
Maintenance | 235
Installing Interface Cards
CAUTION: You must power down the terminal before removing or installing interface cards.
Interface cards are initially installed in the factory to the customers’ requirements however, during the
life of the product, additional interface cards may need to be installed.
Unless the terminals are protected (see ‘Protected terminals’ on page 197), installing new interface cards
involves a substantial interruption of traffic across the link. Staff performing this task must have the
appropriate level of education and experience; it should not be attempted by inexperienced personnel.
To install an interface card:
1. Switch off the power to the terminal.
2. Prepare the terminal for new interface cards (see ‘Preparing the Terminal for New Interface Cards’ on
page 236).
3. Install the interface card (see ‘Installing an Interface Card’ on page 238).
4. Power up the terminal.
5. Configure the slot (see ‘Configuring a Slot’ on page 240).
A slot can be configured before installing a new interface card, or after the interface card is installed
and the terminal power cycled.
6. Configure the cross connections. (see ‘Configuring the traffic cross connections’ on page 158)
Aprisa XE User Manual
236 | Maintenance
Preparing the Terminal for New Interface Cards
To prepare the terminal for a new interface card:
1. Remove the terminal from service by first switching off the terminal power. For an AC powered
terminal, remove the AC power connector. For a DC powered terminal, switch off the DC circuit
breaker or supply fuse.
2. Remove all other cables from the terminal, marking their locations first, if necessary, to aid later
restoration. The safety earth connection must be the last cable removed.
3. Ensure you have unobstructed access to the top and front of the terminal. Remove the terminal from
the equipment rack, if required.
4. Remove the top cover of the terminal by removing two socket screws from the rear.
Note: The top cover slides back towards the rear of the chassis.
5. Remove the front fascia by removing the four front panel socket screws.
Note: The front fascia first hinges out to clear the antenna connector and earth stud, and is then
removed by unclipping from the chassis and sliding downwards. See illustration below.
Aprisa XE User Manual
Maintenance | 237
6. Remove the card securing screw from the required interface slot.
7. There are two types of interface slot blanking plates, the seven tab break off and the single slot type
(newer type).
If the blanking plate is the seven tab break off, remove the slot blanking tab by folding the tab to and
fro until it breaks off.
If the blanking plate is the single slot type, unclip the blanking plate from behind the slot (assuming
that the card securing screw has already been removed).
Aprisa XE User Manual
238 | Maintenance
Installing an Interface Card
To install an interface card:
1. Remove the interface card from its packaging and static-safe bag.
CAUTION: To avoid static damage to the terminal or the interface card being installed, use a static
discharge wristband or similar antistatic device.
2. Offer the interface card into the chassis at an angle until the front panel of the card engages in the
chassis.
3. Rotate the card in the chassis until it is level, and both parts of the card interface bus connector
engage with the socket. Push down evenly on the interface card to seat it into the socket.
Aprisa XE User Manual
Maintenance | 239
4. Replace the card securing screw.
Note: Some interface cards may not have the bracket to accept the card securing screw.
5. Replace the fascia and top covers, restore all cables, and power up the terminal.
Aprisa XE User Manual
240 | Maintenance
Configuring a Slot
1. Select Link or Local or Remote > Interface > Slot Summary.
2. Select the required slot and click Configure Slot.
'Slot' shows the slot the interface card is plugged into in the terminal (A – H).
Details of the interface card currently installed in the slot are:
'HSC’ (hardware software compatibility) A number used by the system software to determine
which FPGA ‘firmware image file’ to use in the interface card installed.
'H/W Rev’ (hardware revision).
‘Installed’ field shows the actual interface card installed in the slot. If there is no interface card
installed in the slot, this field will show ‘none’.
‘Expected’ shows interface card type that had been previously installed. Interface cards can be setup
before they are installed in the terminal or after they are installed in the terminal.
3. To setup a new interface card in a slot, select the interface card type you want to fit (or has been
fitted) from the ‘Expected’ drop-down menu.
Note: The transmitter, receiver and modem are configured in other sections (see ‘Configuring the
terminal’ on page 69).
4. Click Apply to apply changes or Reset to restore the previous configuration.
Aprisa XE User Manual
Troubleshooting | 241
14. Troubleshooting
Loopbacks
Loopbacks are used as a tool for testing or as part of the commissioning process and will affect customer
traffic across the link.
The terminal supports three types of loopbacks:
RF radio loopback
Interface loopbacks, set at the interface ports
Timeslot loopbacks
RF Radio Loopback
The RF radio loopback provides a loopback connection between the radio TX and radio RX. Each terminal
is looped back independently.
All traffic entering the transmit stage of the transceiver is transmitted on the RF link but is also looped
back to the receiver section of the transceiver. This loopback will affect all traffic through the terminal.
When the RF loopback is activated, both the radio RX and TX LEDs will flash.
An RF loopback will automatically deactivate after the period set (in seconds) in the RF Loopback Timeout
field. The default entry is 3600 seconds (60 minutes).
When an RF loopback is activated, the ethernet path is disabled to prevent ethernet loopbacks.
An RF loopback is deactivated if the terminal is rebooted.
To activate or deactivate the RF loopback:
Select Link or Local or Remote > Maintenance > Loopbacks.
To activate the RF loopback, tick the RF Loopback checkbox. Untick the checkbox to deactivate it.
Click Apply to apply changes or Reset to restore the previous configuration.
Aprisa XE User Manual
242 | Troubleshooting
Interface Loopbacks
The interface loopback provides a loopback connection for the customer-connected equipment.
These loopbacks are applied on a port-by-port basis and can only be enabled on active ports i.e. the port
has to be activated by assigning traffic to it by the Cross Connections application.
These are two types of interface loopbacks:
Line Facing – port traffic from the customer is transmitted over the RF link but is also looped back to the
customer
Radio Facing – traffic received from the RF link is passed to the customer port but is also looped back to
be transmitted over the RF link.
Loopback type
Description
QJET
(whole tributary)
The QJET interface port has both Line Facing and Radio Facing loopbacks (see
‘QJET Port Settings’ on page 102).
The interface card green LED flashes while the loopback is active.
QJET
(individual timeslot)
The Cross Connections application can loopback framed E1 / T1 timeslots (see
‘Timeslot Loopbacks’ on page 243).
Q4EM port
The Q4EM interface port has both Line Facing and Radio Facing loopbacks (see
‘Q4EM Port Settings’ on page 104).
The interface card yellow LED flashes while the loopback is active.
DFXO port
The DFXO interface Line Facing loopback loops back the port data to the
customer. This loopback is performed on the digital path of the codec.
The interface card yellow LED flashes while the loopback is active.
DFXS port
The DFXS interface Line Facing loopback loops back the port data to the
customer. This loopback is performed on the digital path of the codec.
The interface card yellow LED flashes while the loopback is active.
HSS port
The HSS interface Line Facing loopback loops back the port data to the
customer.
The interface card top green LED flashes while the loopback is active.
QV24 port
The QV24 interface Line Facing loopback will loop back the port data to the
customer.
Ethernet
No loopback possible.
Aprisa XE User Manual
Troubleshooting | 243
Timeslot Loopbacks
You can loopback framed E1 / T1 timeslots in the Cross Connections application.
1. Open the Cross Connections application.
2. Right-click the timeslot you want to loop back.
3. Select Timeslot Loopback - the looped timeslot will display in black:
Aprisa XE User Manual
244 | Troubleshooting
Alarms
The LEDs (OK, RX, and TX) on the front panel illuminate either amber or red when there is a fault
condition:
Amber indicates a minor alarm that should not affect traffic across the link.
Red indicates a major alarm condition that could affect traffic across the link.
A major or minor alarm can be mapped to the external alarm outputs (see ‘Configuring the External Alarm
Outputs’ on page 83).
Diagnosing Alarms
To view the Alarm Summary and their current states:
Select Link or Local or Remote > Alarms > Summary.
Aprisa XE User Manual
Troubleshooting | 245
Alarm
Explanation
Synthesizer Status
The selected transmit frequency is outside the tuning range of the
transmitter synthesizer
Modem Lock
The terminal modem is not synchronized with the modem at the other end
of the link
TX Temp Shutdown
The transmitter power amplifier temperature is greater than 75°C. The
transmitter has shut down to prevent damage.
TX Temp Warning
The transmitter power amplifier temperature is greater than 70°C. The
transmitter will continue to operate in this condition, but if the power
amplifier temperature increases above 75°C, a major alarm condition is
set and the transmitter will shut down to prevent further damage.
TX AGC Voltage
The transmitter power amplifier automatic gain control is out of limits for
normal operation
TX Reverse Power
There is excessive reflected power at the transmitter port of the terminal,
indicating a low return loss in the path between transmitter port and the
antenna.
TX Return Loss
Status
Indicates the difference between the transmitted power and the amount
of power being reflected back into the terminal. The alarm will trigger
when there is too much reflected power from the antenna that will
degrade link performance.
RX RSSI
The RX RSSI alarm threshold is determined by the RSSI Thresholds for each
of the modulation types (see ‘Setting the RSSI Alarm Threshold’ on page
80)
Fan 1
The internal cooling fan 1 is not operating
Fan 2
The internal cooling fan 2 is not operating
External Input 1 -2
Indicates an active alarm state on the the external alarm input
Alarm Output 1 - 4
Indicates an active alarm state on the the external alarm output
MHSB Switch
Indicates that the MHSB has switched over. The MHSB alarm is only shown
if MHSB mode is enabled (see ‘Configuring the Terminals for MHSB’ on
page 188).
To view detailed alarm information:
Select Link or Local or Remote > Alarms > Alarm Table
The Alarm Table shows the source of the alarm and the type, the slot (and port, if applicable) where the
alarm originated, the severity and the date and time the alarm occurred.
To further diagnose the cause of the alarm (see ‘Identifying Causes of Alarms’ on page 250, and ‘Alarm
Types’ on page 275).
Aprisa XE User Manual
246 | Troubleshooting
Viewing the Alarm History
The alarm history page shows the historical alarm activity for up to 50 alarms. This page refreshes every
30 seconds.
The alarm history for up to 100 alarms can be seen using SNMP (see ‘Configuring SNMP’ on page 85).
To view the alarm history:
Select Link or Local or Remote > Alarms > Alarm History.
Field
Explanation
Source
The component within the terminal that generated the alarm
Type
The type of alarm (see ‘Alarm types and sources’ on page 275)
Slot
The slot where the alarm originated, if applicable
Port
The port where the alarm originated, if applicable
Severity
Whether the alarm was a major or minor alarm
Status
Whether the alarm is active or cleared
Time
The date and time when the alarm occurred
To clear the alarm history:
Select Local or Remote > Alarms > Clear History
This function clears all the alarm history including the 600 alarm rolling buffer (see ‘Saving the Alarm
History’ on page 247).
Aprisa XE User Manual
Troubleshooting | 247
Saving the Alarm History
The last 1500 alarms are stored in a rolling buffer which can be saved as a *.csv file.
To save the alarm history:
Select Local > Alarms > Save History
A File Download dialog box opens.
Click on Save to save the *.csv file to a folder or click on Open to open the file in the SuperVisor page.
Example of file:
Source
Type
Slot
Port
Severity
Status
Time
Modem
Modem
Modem
QV24
QV24
QV24
System
Modem
Modem
Modem
Transmitter
Transmitter
System
QV24
QV24
QV24
HSS
HSS
QJET
mdLOS
mdTdmAlignmentLost
mdDemodAlignmentLost
v24CtrlLineLoss
v24CtrlLineLoss
v24CtrlLineLoss
mdClkSyncFail
mdLOS
mdTdmAlignmentLost
mdDemodAlignmentLost
txADCChZeroLo
txADCChZeroLo
mdClkSyncFail
v24CtrlLineLoss
v24CtrlLineLoss
v24CtrlLineLoss
hssLoss
hssLoss
LOS
Aux
Aux
Aux
---Aux
Aux
Aux
Transmitter
Transmitter
---G
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Minor
Minor
Minor
Active
Active
Active
Active
Active
Active
Active
Cleared
Cleared
Cleared
Active
Cleared
Cleared
Cleared
Cleared
Cleared
Active
Cleared
Active
Tue Jan 22 12:45:54 2008
Tue Jan 22 12:45:54 2008
Tue Jan 22 12:45:54 2008
Tue Jan 22 12:45:55 2008
Tue Jan 22 12:45:55 2008
Tue Jan 22 12:45:55 2008
Tue Jan 22 12:45:57 2008
Tue Jan 22 12:45:57 2008
Tue Jan 22 12:45:57 2008
Tue Jan 22 12:45:57 2008
Tue Jan 22 12:45:57 2008
Tue Jan 22 12:45:58 2008
Tue Jan 22 12:45:58 2008
Tue Jan 22 12:45:59 2008
Tue Jan 22 12:45:59 2008
Tue Jan 22 12:45:59 2008
Tue Jan 22 13:51:17 2008
Tue Jan 22 13:51:17 2008
Tue Jan 22 13:51:35 2008
SNR
(dB)
35.28
35.29
35.26
35.28
35.27
35.29
RSSI
(dBm)
-52.8
-52.8
-52.8
Note: Windows security settings can prevent the download of files. In this case, click on the windows
security message and select the SuperVisor menu option again (Alarms > Save History).
To save the alarm history from the Remote terminal, login to the Remote terminal and Select Local >
Alarms > Save History.
Aprisa XE User Manual
248 | Troubleshooting
Viewing Interface Alarms
To view the alarms for a particular interface:
1. Select Link or Local or Remote > Interface > Interface Summary.
2. Select the desired interface card slot from the Interface Summary and click Alarms.
This opens a page as shown below with a summary of the alarms on the interface card:
The following fields are displayed:
Source: The type of interface card that generated the alarm
Type: The type of interface alarm
Slot: The slot of the interface card that generated the interface alarm
Port: The port that generated the interface alarm
Severity: Whether the interface alarm was major or minor
3. Return to the Interface Summary page by either selecting Options > Interface Summary or clicking
Back in the browser window.
Aprisa XE User Manual
Troubleshooting | 249
Clearing Alarms
Select Link or Local or Remote > Alarms > Clear Alarms
MHSB Command
If a MHSB switchover event occurs, the OK LED on the front panel changes to amber.
To clear the MHSB switchover alarm:
Select ‘Clear Switched Alarm’ from the MHSB Command drop-down list and click on Apply.
Image Table Alarm
An image table alarm occurs if a problem occurred during the boot process which may have left the image
table in an inconsistent state.
To clear the image table alarm:
The default image table alarm: this indicates that the image table has been rebuilt from defaults. This
can indicate that an incorrect build of software is running on the terminal.
Select ‘Clear the Default Image Table used alarm’ from the Image Table drop-down list and click on Apply.
In addition to clearing the image table alarm, you should verify that the active images in the image table
are correct for the software release.
Upload Alarm
An Upload Alarm occurs if the TFTP Upgrade process fails. This can indicate that the upgrade process
cannot find the TFTP server or cannot find the software version number entered.
To clear the upload alarm alarm:
Select ‘Clear the Upload Failure Alarm’ from the Upload Alarm drop-down list and click on Apply.
Aprisa XE User Manual
250 | Troubleshooting
Identifying Causes of Alarms
The following are possible causes of an alarm.
LED
Colour
Possible causes
OK
Amber
A minor system alarm is set
Red
A major system alarm is set
Amber
Low RSSI or AGC limits have been exceeded
Red
Receiver power supply or synthesizer failure
Amber
AGC, transmitter temperature, forward power or reverse power limits
have been exceeded
Red
Transmit power supply or synthesizer failure
RX
TX
OK LED
Colour
Alarm condition
Suggested action
Amber
Fan failure
Check that the fans are not blocked and can spin freely.
Amber
Interface card
mismatch
Using SuperVisor, check that the expected interface card and the
fitted interface card are the same.
Red
Modem lock
A modem lock alarm is generally seen when other conditions such
as low RSSI are present. If there are no other alarms indicated,
check the following:
The terminal clocking is set up correctly.
Both terminals are using the same modulation.
Both terminals are using the same version of software.
External RF Interference from equipment operating in adjacent
channels.
Check the constellation pattern for evidence of disturbances in
the RF path.
Compare RSSI with the expected values from the original path
engineering calculation. Investigate any large differences.
If the fault persists, contact your local representative.
Red
Interface alarms
Check that the E1 or Ethernet interface cables are fitted
correctly and the equipment they are connected to is functioning
correctly.
Aprisa XE User Manual
Troubleshooting | 251
RX LED
Colour
Alarm condition
Suggested action
Amber
Low RSSI
Check that all antenna and feeder cables are firmly connected
and not damaged or kinked
Check there is no damage to the antenna
Check the TX power and alarm status of the remote terminal
Amber
Receiver AGC
Contact your local 4RF representative
Red
Receiver power
supply
Contact your local 4RF representative
Colour
Alarm condition
Suggested action
Amber
Reverse power
Check that all antenna and feeder cables are firmly connected
and not damaged or kinked
Check there is no damage to the antenna
Check that the Receiver and Transmitter ports are correctly
connected to the High and Low ports of the duplexer
Red
Transmitter
temperature
Check operation of cooling fan or fans
Ensure the air grills on the sides of the terminal are clear
Ensure the ambient air temperature around the equipment is
less than 50˚C
TX LED
Aprisa XE User Manual
252 | Troubleshooting
E1 / T1 Alarm Conditions
The QJET interface yellow LED indicates:
Loss of signal (LOS)
A loss of signal alarm occurs when there is no valid G.703 signal at the E1 / T1 interface RX input from
the downstream system.
This alarm masks the LOF and AIS received alarms.
Loss Of Frame alignment (LOF)
A loss of frame alignment alarm occurs when the E1 / T1 interface RX input receives a valid G.703
signal (code and frequency) but does not receive a valid G.704 signal i.e. no frame alignment word,
from the downstream system (in framed E1 / T1 modes only) (red alarm in framed T1 modes).
This alarm masks the AIS received alarm.
Alarm Indication Signal (AIS)
An AIS received alarm occurs when AIS is received from the downstream system.
An E1 / T1 interface will output AIS to the downstream system if the normal upstream traffic signal is
not available e.g. loss of modem synchronization, loss of RF signal across the link (blue alarm in
framed T1 modes).
Remote Alarm Indicator (RAI)
A remote alarm indicator occurs when RAI is received from the downstream system when it has an
active LOS or LOF alarm (TS0 NFAS bit 3 in framed E1 modes and yellow alarm in framed T1 modes).
TS16 Loss of signal (TS16LOS)
A TS16 loss of signal alarm occurs when there is no valid TS16 signal at the E1 interface RX input from
the downstream system (in E1 PCM 30 modes only).
TS16 Remote Multi-frame Alarm Indicator (RMAI)
A remote multiframe alarm indicator occurs when RMAI is received from the downstream system when
it has an active TS16LOS alarm (TS16 F0 bit 6 in E1 PCM 30 modes only).
TS16 Alarm Indication Signal (TS16AIS)
A TS16 Alarm Indication Signal alarm occurs when AIS is received from the downstream system in TS16.
An E1 interface will output the TS16 AIS signal to the downstream system if the normal TS16 multiframe signal is not available (in E1 PCM 30 modes only).
The QJET interface green LED indicates:
The QJET interface green LED flashes when the E1 / T1 port loopback is active.
Aprisa XE User Manual
Troubleshooting | 253
System Log
SuperVisor automatically keeps a log, known as 'syslog', which captures all alarms, errors and events for
each terminal.
You can specify that the ‘syslog’ is saved to a particular file (see ‘Setting up for Remote Logging’ on page
255). You can then email this file to customer service, if requested, to enable them to fault-find more
accurately.
Checking the Syslog
To view the Syslog:
1. Select Local > Performance > Logging > Syslog.
This opens a new window:
Aprisa XE User Manual
254 | Troubleshooting
2. The system log is quite hard to decipher in Internet Explorer. If you're using Internet Explorer, select
View > Source, which opens the file in a more legible layout in Notepad. Save or print this file, as
required.
3. If you want to save the system log, you can save it from within Notepad (or Internet Explorer). Select
File > Save As. Navigate to where you want to save the file. Enter a meaningful filename and select
'Text File' from the Save As Type drop-down list. Click Save.
You can specify that this file is automatically saved to a computer (see ‘Setting up for Remote Logging’ on
page 255).
Aprisa XE User Manual
Troubleshooting | 255
Setting up for Remote Logging
Note: When setting up to save the system log to a specific computer, be aware that the file is constantly
updated and may get quite large quite quickly.
To set up a terminal for remote logging:
1. Copy the TFTP server application (tftpd32.exe, which is located in the TFTPD directory) from the
terminal product CD into a suitable directory on the PC (for example, C:\Program Files\TFTP Server).
2. Create another directory where you want the system logs to be saved for example;
C:\Aprisa XE Syslog
3. Double-click tftpd32.exe.
4. Click Settings and make sure that both ‘Syslog Server’ and ‘Save syslog message’ boxes are ticked.
5. Click Browse and select a directory where you want the Syslog file to be saved (created in step 2).
6. Click OK to close the Settings dialog box.
Aprisa XE User Manual
256 | Troubleshooting
7. In SuperVisor, select Link or Link or Local or Remote > Terminal > Advanced.
8. In the Remote Syslog Address field, enter the IP address of the PC on which the Syslog server is
running.
9. In the Remote Syslog Port field, enter 514.
10. Reboot the terminal (Link or Local or Remote > Maintenance > Reboot).
11. Open the directory where the system logs are being saved to. You should see a file called syslog.txt.
Aprisa XE User Manual
Interface Connections | 257
15. Interface Connections
RJ-45 Connector Pin Assignments
RJ-45 pin numbering
Interface Traffic Direction
All interface traffic directions and labels used in this manual refer to the direction relative to the
terminal. Refer to the diagram below.
The traffic direction describes the transmit / receive paths and the direction of handshaking and clocking
signals, depending on the interface.
Aprisa XE User Manual
258 | Interface Connections
QJET Interface Connections
Pin
number
Pin function
Direction
TIA-568A wire colour
Transmit
Output
Green/white
Transmit
Output
Green
Not used
Receive
Input
Blue
Receive
Input
Blue/white
Not used
Orange
Not used
Brown/white
Not used
Brown
Orange/white
RJ-45 connector LED indicators
LED
Status
Explanation
Green
On
Normal operation
Yellow
On
Loss of signal (LOS) or
Alarm Indication Signal (AIS) or
Loss Of Frame alignment (LOF) in Framed
modes
Green
Flashing
Port in loopback
The standard QJET interface is 120 ohm balanced.
External Balun transformers can be used to provide a 75 ohm unbalanced interface.
Aprisa XE User Manual
Interface Connections | 259
Ethernet Interface Connections
Pin
number
Pin function
Direction
TIA-568A wire
colour
Transmit
Output
Green/white
Transmit
Output
Green
Receive
Input
Orange/white
Not used
Blue
Not used
Blue/white
Receive
Not used
Brown/white
Not used
Brown
Input
Orange
RJ-45 connector LED indicators
LED
Status
Explanation
Green
On
Ethernet signal received
Green
Flashing
Indicates data traffic present on the interface
Note: Do not connect Power over Ethernet (PoE) connections to the Aprisa XE Ethernet ports as this will
damage the port.
Aprisa XE User Manual
260 | Interface Connections
Q4EM Interface Connections
Pin
number
Pin function
Direction
TIA-568A wire
colour
Input
Green/white
M1
Input
Green
Receive (Ra/R)
Input
Orange/white
Transmit (Tb/R1)
Output
Blue
Transmit (Ta/T1)
Output
Blue/white
Receive (Rb/T)
Input
Orange
Output
Brown/white
E1
Output
Brown
RJ-45 connector LED indicators
LED
Status
Explanation
Green
Off
No external source applied to M wire (no M
wire current flowing)
Green
On
External source applied to M wire (M wire
current flowing)
Green
Flashing
The interface loopback is active
Yellow
Off
E wire relay contact open (no current in
external device)
Yellow
On
E wire relay contact closed (current flowing
in external device)
Aprisa XE User Manual
Interface Connections | 261
E&M Signalling Types
The Q4EM E&M signalling leads are optically isolated, bi-directional lines which can be externally
referenced to meet any of the EIA-464 connection types I, II,IV or V (as shown below).
The M1 lead associated with the M wire detector can be externally referenced to earth or battery as
required.
The E1 lead associated with the E wire output can be externally referenced to earth or battery as
required.
Aprisa XE User Manual
262 | Interface Connections
Aprisa XE User Manual
Interface Connections | 263
DFXS Interface Connections
The subscriber interface connects the terminal to the customer's 2 wire
telephone via a 2 wire line.
Each 2 wire channel has two access points: one connects to a customer; the
other is a local test port.
CAUTION:
If there is a power failure at either terminal, any telephone
connected at the DFXS will not operate.
Please ensure that a separate telephone that is not
dependent on local power is available for use in an
emergency.
RJ-45
Pin number
Pin function
Direction
TIA-568A wire
colour
Not used
Green/white
Not used
Green
Not used
Orange/white
Ring
Bi-directional
Blue
Tip
Bi-directional
Blue/white
Not used
Orange
Not used
Brown/white
Not used
Brown
RJ-45 connector LED indicators
LED
Status
Explanation
Green
Off
Interface operational but not in service
Green
On
Normal operation
Green
Flashing
Cadenced ringing on line
Yellow
Off
No interface alarm
Yellow
On
Interface alarm
Yellow
Flashing
The interface loopback is active
Both LEDs
Flashing
Loss of CAS signals
Aprisa XE User Manual
264 | Interface Connections
DFXO Interface Connections
The DFXO interface connects the terminal to the telephone network via a 2
wire line.
Each DFXO channel has two access points: one connects to a customer; the
other is a local test port.
RJ-45
Pin number
Pin function
Direction
TIA-568A wire
colour
Not used
Green/white
Not used
Green
Not used
Orange/white
Ring
Bi-directional
Blue
Tip
Bi-directional
Blue/white
Not used
Orange
Not used
Brown/white
Not used
Brown
RJ-45 connector LED indicators
LED
Status
Explanation
Green
Off
Interface operational but not in service
Green
On
Normal operation
Green
Flashing
Cadenced ringing on line
Yellow
Off
No interface alarm
Yellow
On
Interface alarm
Yellow
Flashing
The interface loopback is active
Both LEDs
Flashing
Loss of CAS signals
Aprisa XE User Manual
Interface Connections | 265
HSS Interface Connections
The connector on the high-speed synchronous serial interface is a high density
LFH-60 (as used on standard Cisco WAN port serial interface cables and
equivalents).
The interface specification (X.21 / V.35 etc) is automatically changed by simply
changing the type of interface cable connected to the HSS.
LED indicators
LED
Status
Explanation
Top green LED
On
Normal operation
Top green LED
Flashing
Loopback in place
Lower green LED
On
Normal operation
Aprisa XE User Manual
266 | Interface Connections
Synchronous cable assemblies
RS-449 Serial Cable Assembly for DCE (Part number: Cab Sync 449FC)
Pin number
Pin function
Direction
Shield Ground
22
SD+
SD-
Input
Input
23
ST+
ST-
Output
Output
24
RD+
RD-
Output
Output
25
RS+
RS-
Input
Input
26
RT+
RT-
Output
Output
27
CS+
CS-
Output
Output
10
37
LL
SC
Input
11
29
DM+
DM-
Output
Output
12
30
TR+
TR-
Input
Input
13
31
RR+
RR-
Output
Output
17
35
TT+
TT-
Input
Input
19
20
SG
RC
Aprisa XE User Manual
Interface Connections | 267
RS-449 Serial Cable Assembly for DTE (Part number: Cab Sync 449MT)
Pin number
Pin function
Direction
Shield Ground
22
SD+
SD-
Output
Output
23
ST+
ST-
Input
Input
24
RD+
RD-
Input
Input
25
RS+
RS-
Output
Output
26
RT+
RT-
Input
Input
27
CS+
CS-
Input
Input
10
37
LL
SC
Output
11
29
DM+
DM-
Input
Input
12
30
TR+
TR-
Output
Output
13
31
RR+
RR-
Input
Input
17
35
TT+
TT-
Output
Output
19
20
SG
RC
Aprisa XE User Manual
268 | Interface Connections
V.35 Serial Cable Assembly for DCE (Part number: Cab Sync V35FC)
Pin number
Pin function
Direction
Frame Ground
Circuit Ground
RTS
Input
CTS
Output
DSR
Output
RLSD
Output
DTR
Input
LT
Input
SD+
SD-
Input
Input
RD+
RD-
Output
Output
SCTE+
SCTE-
Input
Input
SCR+
SCR-
Output
Output
AA
SCT+
SCT-
Output
Output
V.35 Serial Cable Assembly for DTE (Part number: Cab Sync V35MT)
Pin number
Pin function
Frame Ground
Circuit Ground
RTS
Output
CTS
Input
DSR
Input
RLSD
Input
DTR
Output
LT
Output
SD+
SD-
Output
Output
RD+
RD-
Input
Input
SCTE+
SCTE-
Output
Output
SCR+
SCR-
Input
Input
AA
SCT+
SCT-
Input
Input
Aprisa XE User Manual
Direction
Interface Connections | 269
X.21 Serial Cable Assembly for DCE (Part number: Cab Sync X21FC)
Pin number
Pin function
Direction
Shield Ground
Transmit+
Transmit-
Input
Input
10
Control+
Control-
Input
Input
11
Receive+
Receive-
Output
Output
12
Indication+
Indication-
Output
Output
13
Timing+
Timing-
Output
Output
Circuit Ground
X.21 Serial Cable Assembly for DTE (Part number: Cab Sync X21MT)
Pin number
Pin function
Direction
Shield Ground
Transmit+
Transmit-
Output
Output
10
Control+
Control-
Output
Output
11
Receive+
Receive-
Input
Input
12
Indication+
Indication-
Input
Input
13
Timing+
Timing-
Input
Input
Circuit Ground
Aprisa XE User Manual
270 | Interface Connections
RS-530 Serial Cable Assembly for DCE (Part number: Cab Sync 530FC)
Pin number
Pin function
Direction
14
BA(A), TXD+
BA(B), TXD-
Input
Input
16
BB(A), RXD+
BB(B), RXD-
Output
Output
19
CA(A), RTS+
CA(B), RTS-
Input
Input
13
CB(A), CTS+
CB(B), CTS-
Output
Output
22
CC(A), DSR+
CC(B), DSR-
Output
Output
Shield
10
CF(A), DCD+
CF(B), DCD-
Output
Output
15
12
DB(A), TXC+
DB(B), TXC-
Output
Output
17
DD(A), RXC+
DD(B), RXC-
Output
Output
18
LL
Circuit Ground
Input
20
23
CD(A), DTR+
CD(B), DTR-
Input
Input
24
11
DA(A), TXCE+
DA(B), TXCE-
Input
Input
25
TM, not used
Output
Aprisa XE User Manual
Interface Connections | 271
RS-530 Serial Cable Assembly for DTE (Part number: Cab Sync 530MT)
Pin number
Pin function
Direction
14
BA(A), TXD+
BA(B), TXD-
Output
Output
16
BB(A), RXD+
BB(B), RXD-
Input
Input
19
CA(A), RTS+
CA(B), RTS-
Output
Output
13
CB(A), CTS+
CB(B), CTS-
Input
Input
22
CC(A), DSR+
CC(B), DSR-
Input
Input
Shield
10
CF(A), DCD+
CF(B), DCD-
Input
Input
15
12
DB(A), TXC+
DB(B), TXC-
Input
Input
17
DD(A), RXC+
DD(B), RXC-
Input
Input
18
LL
Circuit Ground
Output
20
23
CD(A), DTR+
CD(B), DTR-
Output
Output
24
11
DA(A), TXCE+
DA(B), TXCE-
Output
Output
25
TM, not used
Output
Aprisa XE User Manual
272 | Interface Connections
Cable WAN Connectors
Cisco LFH-60
cable name
WAN connector
Connector gender
Label on WAN end
449FC
DB-37
female
'to DTE'
449MT
DB-37
male
'to DCE'
V35FC
M34
female
'to DTE'
V35MT
M34
male
'to DCE'
X21FC
DB-15
female
'to DTE'
X21MT
DB-15
male
'to DCE'
530FC
DB-25
female
'to DTE'
530MT
DB-25
male
'to DCE'
Aprisa XE User Manual
Interface Connections | 273
QV24 Interface connections
The QV24 is always configured as a DCE:
RJ45
Pin number
Pin function
Direction
TIA-568A wire
colour
RTS
Input
Green / white
DTR
Input
Green
TXD
Input
Orange / white
Ground
Blue
Ground
Blue / white
RXD
Output
Orange
DSR
Output
Brown / white
CTS
Output
Brown
RJ-45 connector LED indicators
LED
Status
Explanation
Green
On / flashing
Transmit data
Yellow
On / flashing
Receive data
QV24S Interface connections
The QV24S is always configured as a DCE:
RJ45
Pin number
Pin function
Direction
TIA-568A wire
colour
RTS
Input
Green / white
XTXC
Input
Green
TXD
Input
Orange / white
Ground
Blue
Ground
Blue / white
RXD
Output
Orange
RXC
Output
Brown / white
CTS
Output
Brown
RJ-45 connector LED indicators
LED
Status
Explanation
Green
On / flashing
Transmit data
Yellow
On / flashing
Receive data
Aprisa XE User Manual
Alarm Types and Sources | 275
16. Alarm Types and Sources
Alarm Types
Transmitter Alarms
Transmitter Alarms for all Frequency Bands
Type
Explanation
tx11VFail
The transmitter 11 VDC power supply has failed
tx28VFail
The transmitter 28 VDC power supply has failed
tx5VFail
The transmitter 5 VDC power supply has failed
txAmplifierBalance
One side of the transmitter amplifier has failed
txEEFail
The transmitter on-board memory has failed
txMibFail
The transmitter MIB is corrupt in EEPROM
txReturnLoss
The transmitter return loss is high
txSynthLD
The transmitter synthesizer frequency is not set
txTSensorFail
The transmitter temperature sensor has failed
Transmitter Alarms for 300, 400, 600, 700, 800, 900, 1400 MHz Frequency Bands
txADCChZeroLo
The transmitter AGC voltage is low
txADCChZeroHi
The transmitter AGC voltage is high
txADCChOneLo
The transmitter Forward Power Monitor reading is low
txADCChOneHi
The transmitter Forward Power Monitor reading is high
txADCChTwoLo
The transmitter Reverse Power Monitor reading is low
txADCChTwoHi
The transmitter Reverse Power Monitor reading is high
txADCChThreeHi
The transmitter temperature is greater than 75°C and the
transmitter has shut down
txADCChFourLo
The transmitter synthesizer tuning voltage is low
txADCChFourHi
The transmitter synthesizer tuning voltage is high
txADCChFiveLo
The transmitter 28 VDC power supply voltage is low
txADCChFiveHi
The transmitter 28 VDC power supply voltage is high
txADCChSixLo
The transmitter 11 VDC power supply voltage is low
txADCChSixHi
The transmitter 11 VDC power supply voltage is high
txADCChSevenLo
The transmitter digital 5 VDC power supply voltage is low
txADCChSevenHi
The transmitter digital 5 VDC power supply voltage is high
txADCChEightLo
The transmitter reference 7 VDC power supply voltage is low
txADCChEightHi
The transmitter reference 7 VDC power supply voltage is high
txADCChNineLo
The transmitter VCO voltage is low
txADCChNineHi
The transmitter VCO voltage is high
txADCChElevenHi
The transmitter temperature is greater than 70°C.
Aprisa XE User Manual
276 | Alarm Types and Sources
Transmitter Alarms for 2000, 2500 MHz Frequency Bands
txADCChZeroLo
The transmitter AGC voltage is low
txADCChZeroHi
The transmitter AGC voltage is high
txADCChOneLo
The transmitter Forward Power Monitor reading is low
txADCChOneHi
The transmitter Forward Power Monitor reading is high
txADCChTwoLo
The transmitter Reverse Power Monitor reading is low
txADCChTwoHi
The transmitter Reverse Power Monitor reading is high
txADCChThreeHi
The transmitter temperature is greater than 75°C and the
transmitter has shut down
txADCChFourLo
The transmitter synthesizer tuning voltage is low
txADCChFourHi
The transmitter synthesizer tuning voltage is high
txADCChFiveLo
The transmitter 28 VDC power supply voltage is low
txADCChFiveHi
The transmitter 28 VDC power supply voltage is high
txADCChSixLo
The transmitter 9 VDC power supply voltage is low
txADCChSixHi
The transmitter 9 VDC power supply voltage is high
txADCChSevenLo
The transmitter digital 5 VDC power supply voltage is low
txADCChSevenHi
The transmitter digital 5 VDC power supply voltage is high
txADCChEightLo
The transmitter reference -5 VDC power supply voltage is low
txADCChEightHi
The transmitter reference -5 VDC power supply voltage is high
txADCChNineLo
The transmitter VCO voltage is low
txADCChNineHi
The transmitter VCO voltage is high
txADCChElevenHi
The transmitter temperature is greater than 70°C.
Aprisa XE User Manual
Alarm Types and Sources | 277
Receiver Alarms
Receiver Alarms for all Frequency Bands
Type
Explanation
rx12VFail
The receiver 12 VDC power supply has failed
rxEEFail
The on-board memory has failed
rxMibFail
The receiver MIB is corrupt in EEPROM
rxOff
The receiver is off
rxRSSIHi
The receiver maximum input level has been exceeded
rxRSSILo
The RSSI is below the alarm threshold setting (see page 80)
rxSynthLD
The synthesizer frequency is not set
Receiver Alarms for 300, 400, 600, 700, 800, 900 MHz Frequency Bands
rxADCChZeroLo
The receiver 3.3 VDC power supply voltage is low
rxADCChZeroHi
The receiver 3.3 VDC power supply voltage is high
rxADCChOneLo
The receiver synthesizer tuning voltage is low
rxADCChOneHi
The receiver synthesizer tuning voltage is high
rxADCChTwoLo
The receiver +12 VDC power supply is low
rxADCChTwoHi
The receiver +12 VDC power supply is high
rxADCChThreeLo
The receiver +5 VDC power supply is low
rxADCChThreeHi
The receiver +5 VDC power supply is high
rxADCChFourLo
The receiver +12 VDC power supply is low (same alarm as TwoLo)
rxADCChFourHi
The receiver +12 VDC power supply is high (same alarm as TwoHi)
rxADCChFiveLo
The receiver VCO voltage is low
rxADCChFiveHi
The receiver VCO voltage is high
rxADCChSevenLo
The receiver RSSI is lower than the normal operating lower limit
rxADCChSevenHi
The receiver RSSI is higher than the normal operating upper limit
rxADCChEightLo
The receiver temperature is greater than 70°C (below spec)
rxADCChEightHi
The receiver temperature is less than -10°C (below spec)
Aprisa XE User Manual
278 | Alarm Types and Sources
Receiver Alarms for 1400 MHz Frequency Band
rxADCChZeroLo
The receiver 3.3 VDC power supply voltage is low
rxADCChZeroHi
The receiver 3.3 VDC power supply voltage is high
rxADCChOneLo
The receiver synthesizer tuning voltage is low
rxADCChOneHi
The receiver synthesizer tuning voltage is high
rxADCChTwoLo
The receiver -1.5 VDC power supply is low
rxADCChTwoHi
The receiver -1.5 VDC power supply is high
rxADCChThreeLo
The receiver +5 VDC power supply is low
rxADCChThreeHi
The receiver +5 VDC power supply is high
rxADCChFourLo
The receiver +9 VDC power supply is low
rxADCChFourHi
The receiver +9 VDC power supply is high
rxADCChFiveLo
The receiver VCO voltage is low
rxADCChFiveHi
The receiver VCO voltage is high
rxADCChSevenLo
The receiver RSSI is lower than the normal operating lower limit
rxADCChSevenHi
The receiver RSSI is higher than the normal operating upper limit
rxADCChEightLo
The receiver temperature is greater than 70°C (below spec)
rxADCChEightHi
The receiver temperature is less than -10°C (below spec)
Aprisa XE User Manual
Alarm Types and Sources | 279
Receiver Alarms for 2000, 2500 MHz Frequency Bands
rxADCChZeroLo
The receiver 3.3 VDC power supply voltage is low
rxADCChZeroHi
The receiver 3.3 VDC power supply voltage is high
rxADCChOneLo
The receiver synthesizer tuning voltage is low
rxADCChOneHi
The receiver synthesizer tuning voltage is high
rxADCChTwoLo
The receiver +12 VDC power supply is low
rxADCChTwoHi
The receiver +12 VDC power supply is high
rxADCChThreeLo
The receiver +5 VDC power supply is low
rxADCChThreeHi
The receiver +5 VDC power supply is high
rxADCChFourLo
The receiver +9 VDC power supply is low
rxADCChFourHi
The receiver +9 VDC power supply is high
rxADCChFiveLo
The receiver VCO voltage is low
rxADCChFiveHi
The receiver VCO voltage is high
rxADCChSevenLo
The receiver RSSI is lower than the normal operating lower limit
rxADCChSevenHi
The receiver RSSI is higher than the normal operating upper limit
rxADCChEightLo
The receiver temperature is greater than 70°C (below spec)
rxADCChEightHi
The receiver temperature is less than -10°C (below spec)
Aprisa XE User Manual
280 | Alarm Types and Sources
MUX Alarms
Type
Explanation
muxInit
A MUX card failed to program
muxMibEEFail
The MIB EEROM is corrupt
muxCharEEFail
The character data is corrupt
Modem Alarms
Type
Explanation
mdLOS
The modem has loss of synchronization with the far end
mdDemodAlignmentLost
The modem is unable to synchronize to the payload framing
mdTdmAlignmentLost
The modem is unable to synchronize to the system bus timing
mdRefAFail
The modem reference clock A has failed
mdRefBFail
The modem reference clock B has failed
mdClkSyncFail
The modem is unable to synchronize to the system clock
mdEEFail
The modem EEPROM is corrupt
mdUCEPresent
The modem has uncorrectable errors
Motherboard Alarms
Type
Explanation
mbFan1Fail
Fan 1 failure
mbFan2Fail
Fan 2 failure
mbCardMismatch
The expected interface card is different to the card that is fitted
mbHwHsc
A MUX card has an unsupported HSC number
Aprisa XE User Manual
Alarm Types and Sources | 281
QJET Alarms
Type
Explanation
e1AIS
The E1 interface RX input has received an Alarm Indication Signal
from the downstream equipment.
e1RAI
The E1 interface RX input has received a Remote Alarm Indication
alarm (RAI) from the downstream equipment.
A remote alarm indicator signal is sent from the downstream
equipment when it has an active LOS or LOF alarm.
e1LOS
The E1 interface Loss Of Signal alarm (LOS)
e1CRC4
The E1 interface Cyclic Redundancy Check 4 alarm indicates a loss
of or corrupted CRC data.
e1LOF
The E1 interface Loss Of Frame alignment (LOF)
e1RMAI
The E1 interface RX input has received an RMAI from the
downstream equipment.
A TS16 remote alarm indicator signal is sent from the downstream
equipment when it has an active TS16 LOS or LOF alarm.
e1TS16AIS
The E1 interface RX input has received a TS16 Alarm Indication
Signal from the downstream equipment.
e1TS16LOS
The E1 timeslot 16 Loss Of Signal alarm
t1AIS
The T1 interface RX input has received an Alarm Indication Signal
from the downstream equipment (AIS Received alarm)
t1RAI
The T1 interface RX input has received a Remote Alarm Indication
alarm (RAI) from the downstream equipment.
t1LOS
The T1 interface Loss Of Signal alarm (LOS)
t1LOF
The T1 interface Loss Of Frame alignment (LOF)
DFXO Alarms
Type
Explanation
fxoCodecOvld
The DFXO detected a codec receive signal overload
fxoBillToneOvld
The DFXO detected a billing tone input signal overload (greater
than 0.8 Vrms into 200 Ω)
fxoUnplug
The DFXO detected that the exchange line has been unplugged
from interface
fxoCurrentOvld
The DFXO Loop current overload detected (greater than 100 mA)
DFXS Alarms
Type
Explanation
fxsCalibError
The phone was off-hook during the DFXS initialization phase
(during power up)
fxsDCDCError
The DFXS DC-DC converter has a low battery voltage error
fxsCasLock
The DFXS has a loss of CAS lock
Aprisa XE User Manual
282 | Alarm Types and Sources
HSS Alarms
Type
Explanation
hssLoss
The HSS has a loss of control pattern
hssRxFifoFull
The HSS RX FIFO has an overrun
hssRxFifoEmpty
The HSS RX FIFO has an underrun
hssTxFifoFull
The HSS TX FIFO has an overrun
hssTxFifoEmpty
The HSS TX FIFO has an underrun
hssRxClockInvalid
The HSS RX clock is invalid
hssTxClockInvalid
The HSS TX clock is invalid
QV24 Alarms
Type
Explanation
v24CtrlLineLoss
The V.24 control lines are not in sync.
External Alarm Inputs
Type
Explanation
externalAlarm1
There has been an alarm on external alarm input 1.
externalAlarm2
There has been an alarm on external alarm input 2.
Remote Terminal Alarms
Type
Explanation
remoteMajorAlarm
There has been a major alarm on the remote terminal.
remoteMinorAlarm
There has been a minor alarm on the remote terminal.
Aprisa XE User Manual
Alarm Types and Sources | 283
Cross Connect Alarms
Type
Explanation
ccNoBandwidth
There is insufficient bandwidth for the current cross connection
configuration.
MHSB Alarms
Type
Explanation
mhsbSwitchToStandby
The terminal has switched from active to standby.
HSD Alarms
Type
Explanation
Mode Switch Software
Override
This alarm provides a warning if the SuperVisor ‘Active Radio’ HSD
Control has overwritten the PSC Mode Switch.
Companion Tx Fail
This alarm occurs on Radio A if the Radio B transmitter (HSD
Companion) has failed. This alarm could be caused by a missing
RF cable between Radio A and Radio B.
hsdCompanionLost
This alarm occurs if there is no traffic from the HSD Companion
radio. This alarm could be caused by a missing traffic cable
between Radio A PSC card and Radio B PIC card.
pscMuxAlignmentError
This alarm occurs if the TDM mux loses alignment to the TDM bus.
This alarm could be caused by a Radio A PSC hardware failure.
pscDemuxAlignmentLost
This alarm occurs if there is a change in state of the PSC Demux
alignment. This alarm could be caused by a HSD system receiver
signal loss (both Radio A and Radio B).
pscTDMAlignmentLost
This alarm occurs if there is a change in state of the PSC TDM
alignment. This alarm could be caused by a HSD system receiver
signal loss (both Radio A and Radio B) or a Radio A PSC hardware
failure.
hsdParamMismatch
This alarm occurs if there is a parameter setting mismatch
between Radio A and Radio B.
The Parameter Mismatch alarms only occur if the HSD Control
‘Parameter Compare Checking’ option is set to ‘On’.
hsdPMTxPower
This alarm occurs if there is a parameter mismatch between
Radio A and Radio B transmitter power setting.
hsdPMTermRfChWidth
This alarm occurs if there is a parameter mismatch between
Radio A and Radio B channel size setting.
hsdPMTxFreq
This alarm occurs if there is a parameter mismatch between
Radio A and Radio B transmitter frequency setting.
hsdPMRxFreq
This alarm occurs if there is a parameter mismatch between
Radio A and Radio B receiver frequency setting.
hsdPMTermModState
This alarm occurs if there is a parameter mismatch between
Radio A and Radio B modulation setting.
hsdPMModemIntlvEna
This alarm occurs if there is a parameter mismatch between
Radio A and Radio B modem interleaver setting.
Aprisa XE User Manual
284 | Alarm Types and Sources
Software Alarms
Type
Explanation
Upload Fail
An Upload Fail alarm occurs if the TFTP Upgrade process fails.
This can indicate that the upgrade process cannot find the TFTP
server or cannot find the software version number entered.
defaultImageTableUsed
A default image table alarm indicates that the image table has
been rebuilt from defaults. This can indicate that an incorrect
build of software is running on the terminal.
Aprisa XE User Manual
Country Specific Settings | 285
17. Country Specific Settings
The following table shows the country-specific settings for the DFXO / DFXS interface cards. If the country
you want is not listed, contact the local telephone company for assistance.
Country
DFXO / DFXS Termination / balance
impedance
DFXO
loop
current
limiter
DFXO
on-hook
speed
DFXO
ringing
impedance
DFXO
ringing
detection
threshold
Argentina
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Australia
TN12 220Ω + (820Ω ║ 120nF)
On
26 ms
> 1 MΩ
16 Vrms
Austria
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Bahrain
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Belgium
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Brazil
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Bulgaria
220Ω + (820Ω ║ 120nF)
On
3 ms
> 1 MΩ
16 Vrms
Canada
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Chile
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
China
600Ω and
China 200Ω + (680Ω ║ 100nF)
On
< 500 μs
> 1 MΩ
16 Vrms
Colombia
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Croatia
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Cyprus
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Czech Republic
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Denmark
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Ecuador
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Egypt
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
El Salvador
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Finland
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
France
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Germany
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Greece
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Guam
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Hong Kong
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Hungary
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Iceland
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
India
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Indonesia
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Ireland
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Israel
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Italy
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Japan
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Jordan
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Kazakhstan
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Kuwait
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Aprisa XE User Manual
286 | Country Specific Settings
Latvia
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Lebanon
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Luxembourg
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Macao
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Malaysia
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Malta
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Mexico
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Morocco
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Netherlands
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
New Zealand
BT3 (370Ω + (620Ω ║ 310nF))
On
< 500 μs
> 1 MΩ
16 Vrms
Nigeria
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Norway
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Oman
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Pakistan
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Peru
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Philippines
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Poland
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Portugal
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Romania
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Russia
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Saudi Arabia
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Singapore
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Slovakia
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Slovenia
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
South Africa
TBR21 270Ω + (750Ω ║ 150nF)
On
< 500 μs
> 12 kΩ
16 Vrms
South Korea
600Ω
On
< 500 μs
> 12 kΩ
16 Vrms
Spain
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Sweden
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Switzerland
TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
Taiwan
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Thailand
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
UAE
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
UK
BT Network 320Ω + (1050Ω ║ 230nF)
and TBR21 270Ω + (750Ω ║ 150nF)
On
3 ms
> 1 MΩ
16 Vrms
USA
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Yemen
600Ω
On
< 500 μs
> 1 MΩ
16 Vrms
Aprisa XE User Manual
Specifications | 287
18. Specifications
RF Specifications
ETSI
Frequency Bands ETSI
Frequency Bands ETSI
Frequency Bands ETSI
Frequency
Band
Frequency
Tuning Range
Synthesizer
Step Size
300 MHz
330 - 400 MHz
6.25 kHz
400 MHz
394 - 460 MHz
5.0 kHz
400 MHz
400 - 470 MHz
6.25 kHz
600 MHz
620 - 715 MHz
12.5 kHz
800 MHz
805 - 890 MHz
12.5 kHz
900 MHz
850 - 960 MHz
12.5 kHz
1400 MHz
1350 - 1550 MHz
12.5 kHz
1800 MHz
1700 - 2100 MHz
62.5 kHz
2000 MHz
1900 - 2300 MHz
62.5 kHz
2500 MHz
2300 - 2700 MHz
62.5 kHz
Modulation
16 / 32 / 64 / 128 QAM and QPSK (software configurable)
Frequency stability (short term)
< ±1 ppm
Frequency stability (long term)
< ±2 ppm
Antenna connector
N-type female 50 Ω
Note 1 Frequency Ranges
Country specific frequency ranges within the above tuning ranges can be accommodated
Note 2 Modulation
128 QAM is unreleased: Please contact 4RF for availability.
Note 3 Frequency stability
Short term frequency stability is defined as changes in frequency due to environmental effects and power supply
variations
Long term frequency stability is defined as changes in frequency due to aging of crystal oscillators approx over 5
years
Aprisa XE User Manual
288 | Specifications
Product Range ETSI
The Aprisa XE terminal provides the following ETSI frequency bands / channel sizes:
Channel Size
kHz
MHz
25
50
75
125
150
200
250
500
1.00
1.35
1.75
3.50
7.00
14.00
112
256
400
640
808
1.02
1.24
2.39
4.89
6.62
8.63
17.18
35.51
65.46
300
400
Frequency Band MHz
600
800
900
1400
1800
2000
2500
kbit/s
Mbit/s
Transport capacity @ 64 QAM
Product Released
Product Release Pending
Aprisa XE User Manual
Specifications | 289
Link Capacity ETSI
Channel size
25 kHz
QPSK
Gross
72 kbit/s
E1
Gross
E1
Wayside
75 kHz
Gross
E1
Wayside
125 kHz
Gross
E1
Wayside
150 kHz
Gross
E1
Wayside
200 kHz
Gross
E1
Wayside
250 kHz
Gross
E1
Wayside
500 kHz
Gross
E1
Wayside
1.0 MHz
Gross
E1
Wayside
1.35 MHz
Gross
E1
Wayside
1.75 MHz
Gross
E1
Wayside
3.5 MHz
Gross
E1
Wayside
7.0 MHz
Gross
E1
Wayside
14 MHz
Gross
E1
Wayside
Notes
32 QAM
96 kbit/s
1 timeslot
Wayside
50 kHz
16 QAM
80 kbit/s
1 timeslot
64 QAM
128 QAM
112 kbit/s
136 kbit/s
1 timeslot
1 timeslot
2 timeslots
8 kbit/s
32 kbit/s
48 kbit/s
8 kbit/s
168 kbit/s
208 kbit/s
256 kbit/s
296 kbit/s
2 timeslots
3 timeslots
4 timeslots
4 timeslots
16 kbit/s
40 kbit/s
16 kbit/s
0 kbit/s
40 kbit/s
128 kbit/s
264 kbit/s
312 kbit/s
400 kbit/s
440 kbit/s
2 timeslots
4 timeslots
4 timeslots
6 timeslots
6 timeslots
0 kbit/s
8 kbit/s
56 kbit/s
16 kbit/s
56 kbit/s
208 kbit/s
424 kbit/s
536 kbit/s
640 kbit/s
744 kbit/s
3 timeslots
6 timeslots
8 timeslots
10 timeslots
11 timeslots
16 kbit/s
40 kbit/s
24 kbit/s
0 kbit/s
40 kbit/s
264 kbit/s
536 kbit/s
672 kbit/s
808 kbit/s
944 kbit/s
4 timeslots
8 timeslots
10 timeslots
12 timeslots
14 timeslots
8 kbit/s
24 kbit/s
32 kbit/s
40 kbit/s
48 kbit/s
336 kbit/s
680 kbit/s
840 kbit/s
1024 kbit/s
1168 kbit/s
5 timeslots
10 timeslots
13 timeslots
16 timeslots
18 timeslots
16 kbit/s
40 kbit/s
8 kbit/s
0 kbit/s
16 kbit/s
408 kbit/s
824 kbit/s
1032 kbit/s
1240 kbit/s
1448 kbit/s
6 timeslots
12 timeslots
16 timeslots
19 timeslots
22 timeslots
24 kbit/s
56 kbit/s
8 kbit/s
24 kbit/s
40 kbit/s
792 kbit/s
1592 kbit/s
1992 kbit/s
2392 kbit/s
2792 kbit/s
12 timeslots
24 timeslots
31 timeslots
1 E1
1 E1
24 kbit/s
56 kbit/s
8 kbit/s
304 kbit/s
704 kbit/s
1624 kbit/s
3256 kbit/s
4072 kbit/s
4888 kbit/s
5704 kbit/s
1 E1
1 E1
24 kbit/s
1168 kbit/s
1984 kbit/s
712 kbit/s
1528 kbit/s
2200 kbit/s
4408 kbit/s
5512 kbit/s
6616 kbit/s
7720 kbit/s
25 timeslots
1 E1
2 E1s
2 E1s
2 E1s
3 E1s
2 E1s
3 E1s
112 kbit/s
232 kbit/s
1336 kbit/s
352 kbit/s
1456 kbit/s
2872 kbit/s
5752 kbit/s
7192 kbit/s
8632 kbit/s
10072 kbit/s
1 E1
2 E1s
3 E1s
4 E1s
4 E1s
784 kbit/s
1576 kbit/s
928 kbit/s
280 kbit/s
1720 kbit/s
5720 kbit/s
11448 kbit/s
14312 kbit/s
17176 kbit/s
20040 kbit/s
2 E1s
5 E1s
6 E1s
8 E1s
9 E1s
1544 kbit/s
1008 kbit/s
1784 kbit/s
472 kbit/s
1248 kbit/s
11832 kbit/s
23672 kbit/s
29592 kbit/s
35512 kbit/s
41432 kbit/s
5 E1s
11 E1s
14 E1s
17 E1s
1392 kbit/s
704 kbit/s
360 kbit/s
16 kbit/s
1760 kbit/s
23992 kbit/s
47992 kbit/s
59992 kbit/s
65464 kbit/s
65400 kbit/s
11 E1s
1024 kbit/s
22 E1s
2056 kbit/s
28 E1s
1528 kbit/s
28 E1s
7000 kbit/s
The capacities specified are for Unframed E1 and so require 2088 kbit/s to transport via the radio.
The management ethernet capacity must be subtracted from the gross capacity (default 64 kbit/s).
See Product Range table for Channel Size / Frequency Band cross reference
Aprisa XE User Manual
19 E1s
28 E1s
6936 kbit/s
290 | Specifications
Receiver Sensitivity ETSI
Channel size
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
25 kHz
NA
-105 dBm
-102 dBm
-99 dBm
-96 dBm
50 kHz
-109 dBm
-103 dBm
-100 dBm
-97 dBm
-94 dBm
75 kHz
-107 dBm
-101 dBm
-98 dBm
-95 dBm
-92 dBm
125 kHz
-105 dBm
-99 dBm
-96 dBm
-93 dBm
-90 dBm
150 kHz
-104 dBm
-98 dBm
-95 dBm
-92 dBm
-89 dBm
200 kHz
-102 dBm
-96 dBm
-93 dBm
-90 dBm
-87 dBm
250 kHz
-101 dBm
-95 dBm
-92 dBm
-89 dBm
-86 dBm
500 kHz
-99 dBm
-93 dBm
-90 dBm
-87 dBm
-84 dBm
1.0 MHz
-96 dBm
-90 dBm
-87 dBm
-84 dBm
-81 dBm
1.35 MHz
-95 dBm
-89 dBm
-86 dBm
-83 dBm
-80 dBm
1.75 MHz
-94 dBm
-88 dBm
-85 dBm
-82 dBm
-79 dBm
3.5 MHz
-90 dBm
-84 dBm
-81 dBm
-78 dBm
-75 dBm
7.0 MHz
-87 dBm
-81 dBm
-78 dBm
-75 dBm
-72 dBm
14 MHz
-84 dBm
-78 dBm
-75 dBm
-72 dBm
-69 dBm
Notes
Typical performance specified at the antenna port for 10-6 BER.
The receiver is typically 1 dB more sensitive for a BER of 10-3.
NA (Not Available)
Transmitter Power ETSI
Frequency Band
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
300 MHz
21 to 35 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
400 MHz
21 to 35 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
600 MHz
21 to 35 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
800 MHz
21 to 35 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
900 MHz
21 to 35 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
1400 MHz
21 to 35 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
1800 MHz
21 to 35 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
2000 MHz
20 to 34 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
2500 MHz
20 to 34 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
Aprisa XE User Manual
Specifications | 291
System Gain ETSI
Channel Size
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
25 kHz
NA
136 dB
132 dB
128 dB
125 dB
50 kHz
144 dB
134 dB
130 dB
126 dB
123 dB
75 kHz
142 dB
132 dB
128 dB
124 dB
121 dB
125 kHz
140 dB
130 dB
126 dB
122 dB
119 dB
150 kHz
139 dB
129 dB
125 dB
121 dB
118 dB
200 kHz
137 dB
127 dB
123 dB
119 dB
116 dB
250 kHz
136 dB
126 dB
122 dB
118 dB
115 dB
500 kHz
134 dB
124 dB
120 dB
116 dB
113 dB
1.0 MHz
131 dB
121 dB
117 dB
113 dB
110 dB
1.35 MHz
130 dB
120 dB
116 dB
112 dB
109 dB
1.75 MHz
129 dB
119 dB
115 dB
111 dB
108 dB
3.5 MHz
125 dB
115 dB
111 dB
107 dB
104 dB
7.0 MHz
122 dB
112 dB
108 dB
104 dB
101 dB
14 MHz
119 dB
109 dB
105 dB
101 dB
98 dB
Notes
Typical performance specified at the antenna port for 10-6 BER.
The system gain is typically 1 dB greater for a BER of 10-3.
Figures decrease by 1 dB for the 2000 and 2500 MHz bands at QPSK.
System Gain = maximum transmit power - receiver sensitivity
NA (Not Available)
Aprisa XE User Manual
292 | Specifications
Link Delays ETSI
Note: The default Modem Interleaver Mode setting is on for channel sizes of 250 kHz and greater and off
for channel sizes of 200 kHz and less (see ‘Modem Interleaver Mode’ on page 72).
Typical 1+0, MHSB end-to-end link delay - interleaver off
Channel size
25 kHz
QPSK
NA
16 QAM
32 QAM
64 QAM
128 QAM
51.8 ms
40.6 ms
35.7 ms
30.3 ms
50 kHz
46.2 ms
24.3 ms
20.2 ms
16.9 ms
15.0 ms
75 kHz
30.4 ms
16.2 ms
14.0 ms
11.4 ms
10.6 ms
125 kHz
22.3 ms
12.1 ms
10.0 ms
8.6 ms
7.0 ms
150 kHz
15.9 ms
8.8 ms
7.3 ms
6.4 ms
5.7 ms
200 kHz
12.8 ms
7.2 ms
6.2 ms
5.3 ms
4.9 ms
250 kHz
10.8 ms
6.2 ms
5.3 ms
4.6 ms
4.2 ms
500 kHz
6.3 ms
3.9 ms
3.4 ms
3.1 ms
2.8 ms
1.0 MHz
3.8 ms
2.6 ms
2.3 ms
2.2 ms
2.1 ms
1.35 MHz
3.1 ms
2.3 ms
2.1 ms
2.0 ms
1.9 ms
1.75 MHz
3.1 ms
2.3 ms
2.1 ms
2.0 ms
1.9 ms
3.5 MHz
2.0 ms
1.7 ms
1.6 ms
1.6 ms
1.6 ms
7.0 MHz
1.7 ms
1.5 ms
1.5 ms
1.5 ms
1.4 ms
14 MHz
1.5 ms
1.4 ms
1.4 ms
1.4 ms
1.4 ms
Typical 1+0, MHSB end-to-end link delay - interleaver on
QPSK
25 kHz
32 QAM
64 QAM
128 QAM
153.6 ms
118.9 ms
103.5 ms
86.9 ms
50 kHz
138.8 ms
70.5 ms
57.9 ms
47.8 ms
41.8 ms
75 kHz
90.3 ms
46.1 ms
39.5 ms
31.4 ms
28.8 ms
125 kHz
65.6 ms
33.7 ms
27.3 ms
23.1 ms
17.8 ms
150 kHz
45.8 ms
23.7 ms
19.3 ms
16.4 ms
14.3 ms
200 kHz
36.5 ms
19.0 ms
15.8 ms
13.2 ms
11.8 ms
250 kHz
30.4 ms
16.0 ms
13.1 ms
11.2 ms
9.8 ms
500 kHz
16.5 ms
9.0 ms
7.5 ms
6.5 ms
5.7 ms
1.0 MHz
8.8 ms
5.1 ms
4.3 ms
3.9 ms
3.5 ms
1.35 MHz
6.8 ms
4.1 ms
3.6 ms
3.2 ms
2.9 ms
1.75 MHz
5.6 ms
3.5 ms
3.1 ms
2.8 ms
2.9 ms
3.5 MHz
3.5 ms
2.4 ms
2.2 ms
2.1 ms
2.0 ms
7.0 MHz
2.4 ms
1.9 ms
1.8 ms
1.7 ms
1.7 ms
14 MHz
1.9 ms
1.6 ms
1.6 ms
1.5 ms
1.5 ms
Notes
NA
16 QAM
The end to end link delays are measured from E1 / T1 interface to E1 / T1 interface
The delay figures are typical and can vary when the system re-synchronizes
NA (Not Available)
Aprisa XE User Manual
Specifications | 293
Typical HSD end-to-end link delay - interleaver on
QPSK
25 kHz
16 QAM
NA
32 QAM
64 QAM
128 QAM
305.4 ms
223.2 ms
202.2 ms
NA
50 kHz
247.1 ms
142.0 ms
122.1 ms
95.2 ms
NA
75 kHz
185.3 ms
95.8 ms
82.8 ms
67.0 ms
NA
125 kHz
NA
NA
NA
NA
NA
150 kHz
93.3 ms
47.3 ms
39.5 ms
33.7 ms
NA
200 kHz
75.6 ms
38.9 ms
32.7 ms
25.5 ms
NA
250 kHz
63.6 ms
32.8 ms
25.2 ms
21.6 ms
NA
500 kHz
34.0 ms
17.0 ms
14.8 ms
11.4 ms
NA
1.0 MHz
16.9 ms
9.5 ms
8.0 ms
6.5 ms
NA
1.35 MHz
NA
NA
NA
NA
NA
1.75 MHz
9.9 ms
5.1 ms
4.9 ms
4.4 ms
NA
3.5 MHz
5.5 ms
3.5 ms
3.1 ms
3.1 ms
NA
7.0 MHz
3.6 ms
2.5 ms
2.3 ms
2.3 ms
NA
14 MHz
2.4 ms
2.0 ms
2.0 ms
2.0 ms
NA
Notes
The end to end link delays are measured from E1 / T1 interface to E1 / T1 interface
The delay figures are typical and can vary when the system re-synchronizes
NA (Not Available)
Aprisa XE User Manual
294 | Specifications
FCC
Frequency Bands FCC
Frequency Bands FCC
Frequency
Band
Frequency
Tuning Range
Synthesizer
Step Size
400 MHz
421 - 512 MHz
6.25 kHz
700 MHz
698 - 806 MHz
12.5 kHz
900 MHz
928 - 960 MHz
12.5 kHz
2500 MHz
2314 - 2350 MHz
62.5 kHz
Modulation
16 / 32 / 64 / 128 QAM and QPSK (software configurable)
Frequency stability (short term)
< ±1 ppm
Frequency stability (long term)
< ±2 ppm
Antenna connector
N-type female 50 Ω
Note 1 Frequency bands
Contact 4RF for other frequency band options
Note 2 Modulation
128 QAM is unreleased: Please contact 4RF for availability.
Note 3 Frequency stability
Short term frequency stability is defined as changes in frequency due to environmental effects and power supply variations
Long term frequency stability is defined as changes in frequency due to aging of crystal oscillators approx over 5 years
Product Range FCC
The Aprisa XE terminal provides the following FCC frequency bands / channel sizes:
Channel Size
kHz
Frequency Band MHz
25
400
100
MHz
200
250
500
1.00
Part 27
Part 27
Part 90
700
900
Part 101
Part 101
2500
88
424
Part 27
Part 27
1.24
2.39
952
kbit/s
Mbit/s
Transport capacity @ 64 QAM
Promoted
Product Release Pending
Aprisa XE User Manual
4.98
Specifications | 295
Link Capacity FCC
Channel size
25 kHz
QPSK
Gross
Gross
136 kbit/s
T1
2 timeslots
Wayside
Gross
Gross
500 kHz
T1
1.0 MHz
Gross
Notes
24 kbit/s
40 kbit/s
280 kbit/s
352 kbit/s
424 kbit/s
608 kbit/s
4 timeslots
5 timeslots
6 timeslots
9 timeslots
312 kbit/s
632 kbit/s
792 kbit/s
952 kbit/s
1112 kbit/s
9 timeslots
12 timeslots
14 timeslots
17 timeslots
56 kbit/s
56 kbit/s
24 kbit/s
56 kbit/s
24 kbit/s
408 kbit/s
824 kbit/s
1032 kbit/s
1240 kbit/s
1448 kbit/s
12 timeslots
16 timeslots
19 timeslots
22 timeslots
24 kbit/s
56 kbit/s
8 kbit/s
24 kbit/s
40 kbit/s
792 kbit/s
1592 kbit/s
1992 kbit/s
2392 kbit/s
2792 kbit/s
1 T1
1 T1
1 T1
1 T1
24 kbit/s
8 kbit/s
408 kbit/s
808 kbit/s
1208 kbit/s
1656 kbit/s
3320 kbit/s
4152 kbit/s
4984 kbit/s
5816 kbit/s
T1
1 T1
Wayside
1 timeslot
8 kbit/s
32 kbit/s
12 timeslots
Wayside
1 timeslot
56 kbit/s
40 kbit/s
6 timeslots
Gross
1 timeslot
128 QAM
104 kbit/s
32 kbit/s
T1
Wayside
88 kbit/s
24 kbit/s
4 timeslots
Wayside
64 QAM
8 kbit/s
T1
250 kHz
72 kbit/s
0 timeslots
Wayside
200 kHz
32 QAM
56 kbit/s
T1
100 kHz
16 QAM
72 kbit/s
2 T1s
152 kbit/s
2 T1s
984 kbit/s
3 T1s
232 kbit/s
3 T1s
1064 kbit/s
The capacities specified are for Unframed T1 and so require 1584 kbit/s to transport via the radio.
The management ethernet capacity must be subtracted from the gross capacity (default 64 kbit/s).
See Product Range table for Channel Size / Frequency Band cross reference
Receiver Sensitivity FCC
Channel Size
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
25 kHz
NA
-105 dBm
-102 dBm
-99 dBm
-96 dBm
100 kHz
-106 dBm
-100 dBm
-97 dBm
-94 dBm
-91 dBm
200 kHz
-102 dBm
-96 dBm
-93 dBm
-90 dBm
-87 dBm
250 kHz
-101 dBm
-95 dBm
-92 dBm
-89 dBm
-86 dBm
500 kHz
-99 dBm
-93 dBm
-90 dBm
-87 dBm
-84 dBm
1.0 MHz
-96 dBm
-90 dBm
-87 dBm
-84 dBm
-81 dBm
Notes
Typical performance specified at the antenna port for 10-6 BER.
The receiver is typically 1 dB more sensitive for a BER of 10-3.
Transmit Power FCC
Frequency Band
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
400 MHz
NA
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
700 MHz
21 to 35 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
900 MHz
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
2500 MHz
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
Aprisa XE User Manual
296 | Specifications
System Gain FCC
400 MHz, 700 MHz, 900 MHz
Channel Size
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
25 kHz
NA
136 dB
132 dB
128 dB
125 dB
100 kHz
135 dB
129 dB
126 dB
123 dB
120 dB
200 kHz
131 dB
125 dB
122 dB
119 dB
116 dB
500 kHz
134 dB
124 dB
120 dB
116 dB
113 dB
1.0 MHz
131 dB
121 dB
117 dB
113 dB
110 dB
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
250 kHz
130 dB
124 dB
121 dB
118 dB
115 dB
500 kHz
128 dB
122 dB
119 dB
116 dB
113 dB
2500 MHz
Notes
Typical performance specified at the antenna port for 10-6 BER.
The system gain is typically 1 dB greater for a BER of 10-3.
System Gain = maximum transmit power - receiver sensitivity
Link Delays FCC
Note: The default Modem Interleaver Mode setting is on for channel sizes of 250 kHz and greater and off
for channel sizes of 200 kHz and less (see ‘Modem Interleaver Mode’ on page 72).
Interleaver off
Channel size
25 kHz
QPSK
NA
16 QAM
32 QAM
64 QAM
128 QAM
64.4 ms
52.3 ms
44.2 ms
38.5 ms
100 kHz
28.8 ms
15.3 ms
12.7 ms
10.9 ms
8.2 ms
200 kHz
15.9 ms
8.8 ms
7.3 ms
6.4 ms
5.1 ms
250 kHz
11.2 ms
6.6 ms
5.4 ms
5.0 ms
4.2 ms
500 kHz
5.9 ms
3.5 ms
3.4 ms
3.2 ms
2.8 ms
1.0 MHz
3.8 ms
2.6 ms
2.3 ms
2.2 ms
2.1 ms
Interleaver on
Channel size
25 kHz
QPSK
32 QAM
64 QAM
128 QAM
191.6 ms
154.1 ms
129.1 ms
111.2 ms
100 kHz
85.3 ms
43.6 ms
35.3 ms
29.7 ms
21.4 ms
200 kHz
45.8 ms
23.7 ms
19.3 ms
16.4 ms
12.3 ms
250 kHz
33.2 ms
17.5 ms
14.3 ms
12.1 ms
9.8 ms
500 kHz
17.5 ms
9.3 ms
8.0 ms
6.9 ms
5.7 ms
1.0 MHz
8.8 ms
5.1 ms
4.3 ms
3.9 ms
3.5 ms
Notes
NA
16 QAM
The end to end link delays are measured from E1 / T1 interface to E1 / T1 interface
The delay figures are typical and can vary when the system re-synchronizes
Aprisa XE User Manual
Specifications | 297
Industry Canada
Frequency Bands IC
Frequency Bands IC
Frequency
Band
Frequency
Tuning Range
Synthesizer
Step Size
400 MHz
400 - 470 MHz
6.25 kHz
900 MHz
928 - 960 MHz
12.5 kHz
2000 MHz
1900 - 2300 MHz
62.5 kHz
Modulation
16 / 32 / 64 / 128 QAM and QPSK (software configurable)
Frequency stability (short term)
< ±1 ppm
Frequency stability (long term)
< ±2 ppm
Antenna connector
N-type female 50 Ω
Note 1 Frequency bands
Contact 4RF for other frequency band options
Note 2 Modulation
128 QAM is unreleased: Please contact 4RF for availability.
Note 3 Frequency stability
Short term frequency stability is defined as changes in frequency due to environmental effects and power supply
variations
Long term frequency stability is defined as changes in frequency due to aging of crystal oscillators approx over 5
years
Product Range IC
The Aprisa XE terminal provides the following Industry Canada frequency bands / channel sizes:
Channel Size
Freq Band
kHz
MHz
25
75
100
150
200
500
1.00
1.75
3.50
7.00
14.00
88
400
424
808
952
2.39
4.89
8.63
17.18
35.51
65.46
400
900
2000
kbit/s
Mbit/s
Transport capacity @ 64 QAM
Aprisa XE User Manual
298 | Specifications
Link Capacity IC
Channel size
25 kHz
QPSK
Gross
NA
T1
Gross
T1
Wayside
100 kHz
Gross
T1
Wayside
150 kHz
Gross
T1
Wayside
200 kHz
Gross
T1
Wayside
500 kHz
Gross
T1
Wayside
1.0 MHz
Gross
T1
Wayside
1.75 MHz
Gross
T1
3.5 MHz
2 timeslots
88 kbit/s
1 timeslot
NA
1 timeslot
56 kbit/s
8 kbit/s
24 kbit/s
264 kbit/s
312 kbit/s
400 kbit/s
4 timeslots
128 QAM
4 timeslots
6 timeslots
440 kbit/s
6 timeslots
0 kbit/s
8 kbit/s
56 kbit/s
16 kbit/s
56 kbit/s
136 kbit/s
280 kbit/s
352 kbit/s
424 kbit/s
608 kbit/s
2 timeslots
4 timeslots
5 timeslots
6 timeslots
9 timeslots
8 kbit/s
24 kbit/s
32 kbit/s
40 kbit/s
32 kbit/s
264 kbit/s
536 kbit/s
672 kbit/s
808 kbit/s
944 kbit/s
4 timeslots
8 timeslots
10 timeslots
12 timeslots
14 timeslots
8 kbit/s
24 kbit/s
32 kbit/s
40 kbit/s
48 kbit/s
312 kbit/s
632 kbit/s
792 kbit/s
952 kbit/s
1112 kbit/s
4 timeslots
56 kbit/s
792 kbit/s
12 timeslots
9 timeslots
12 timeslots
14 timeslots
17 timeslots
56 kbit/s
24 kbit/s
56 kbit/s
24 kbit/s
1592 kbit/s
1992 kbit/s
2392 kbit/s
2792 kbit/s
1 T1
1 T1
1 T1
1 T1
24 kbit/s
8 kbit/s
408 kbit/s
808 kbit/s
1208 kbit/s
1624 kbit/s
3256 kbit/s
4072 kbit/s
4888 kbit/s
5704 kbit/s
1 T1
2 T1s
40 kbit/s
88 kbit/s
904 kbit/s
136 kbit/s
952 kbit/s
2872 kbit/s
5752 kbit/s
7192 kbit/s
8632 kbit/s
10072 kbit/s
1 T1
2 T1s
3 T1s
3 T1s
4 T1s
5 T1s
3 T1s
6 T1s
1000 kbit/s
856 kbit/s
712 kbit/s
568 kbit/s
Gross
5720 kbit/s
11448 kbit/s
14312 kbit/s
17176 kbit/s
20040 kbit/s
Gross
T1
Wayside
Gross
T1
Wayside
Notes
128 kbit/s
64 QAM
1288 kbit/s
Wayside
14 MHz
72 kbit/s
Wayside
T1
7.0 MHz
32 QAM
56 kbit/s
0 timeslots
Wayside
75 kHz
16 QAM
3 T1s
7 T1s
9 T1s
10 T1s
12 T1s
968 kbit/s
360 kbit/s
56 kbit/s
1336 kbit/s
1032 kbit/s
11832 kbit/s
23672 kbit/s
29592 kbit/s
35512 kbit/s
41432 kbit/s
7 T1s
14 T1s
18 T1s
22 T1s
26 T1s
744 kbit/s
1496 kbit/s
1080 kbit/s
664 kbit/s
248 kbit/s
NA
47992 kbit/s
59992 kbit/s
65464 kbit/s
65400 kbit/s
30 T1s
472 kbit/s
32 T1s
9304 kbit/s
32 T1s
14776 kbit/s
The capacities specified are for Unframed T1 and so require 1584 kbit/s to transport via the radio.
The management ethernet capacity must be subtracted from the gross capacity (default 64 kbit/s).
See Product Range table for Channel Size / Frequency Band cross reference
NA (Not Available)
Aprisa XE User Manual
32 T1s
14712 kbit/s
Specifications | 299
Receiver Sensitivity IC
Channel size
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
25 kHz
NA
-105 dBm
-102 dBm
-99 dBm
NA
75 kHz
-107 dBm
-101 dBm
-98 dBm
-95 dBm
-92 dBm
100 kHz
-106 dBm
-100 dBm
-97 dBm
-94 dBm
-91 dBm
150 kHz
-104 dBm
-98 dBm
-95 dBm
-92 dBm
-89 dBm
200 kHz
-102 dBm
-96 dBm
-93 dBm
-90 dBm
-87 dBm
500 kHz
-99 dBm
-93 dBm
-90 dBm
-87 dBm
-84 dBm
1.0 MHz
-96 dBm
-90 dBm
-87 dBm
-84 dBm
-81 dBm
1.75 MHz
-94 dBm
-88 dBm
-85 dBm
-82 dBm
-79 dBm
3.5 MHz
-90 dBm
-84 dBm
-81 dBm
-78 dBm
-75 dBm
7.0 MHz
-87 dBm
-81 dBm
-78 dBm
-75 dBm
-72 dBm
14 MHz
NA
-78 dBm
-75 dBm
-72 dBm
-69 dBm
Notes
Typical performance specified at the antenna port for 10-6 BER.
The receiver is typically 1 dB more sensitive for a BER of 10-3.
NA (Not Available)
Transmitter Power IC
Frequency Band
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
400 MHz
15 to 35 dBm
15 to 31 dBm
15 to 30 dBm
15 to 29 dBm
15 to 29 dBm
900 MHz
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
15 to 29 dBm
2000 MHz
20 to 34 dBm
17 to 31 dBm
16 to 30 dBm
15 to 29 dBm
15 to 29 dBm
128 QAM
System Gain IC
Channel Size
QPSK
16 QAM
32 QAM
64 QAM
25 kHz
NA
136 dB
132 dB
128 dB
NA
75 kHz
142 dB
132 dB
128 dB
124 dB
121 dB
100 kHz
135 dB
129 dB
126 dB
123 dB
120 dB
150 kHz
139 dB
129 dB
125 dB
121 dB
118 dB
200 kHz
131 dB
125 dB
122 dB
119 dB
116 dB
500 kHz
133 dB
124 dB
120 dB
116 dB
113 dB
1.0 MHz
130 dB
121 dB
117 dB
113 dB
110 dB
1.75 MHz
128 dB
119 dB
115 dB
111 dB
108 dB
3.5 MHz
124 dB
115 dB
111 dB
107 dB
104 dB
7.0 MHz
121 dB
112 dB
108 dB
104 dB
101 dB
14 MHz
NA
109 dB
105 dB
101 dB
98 dB
Notes
Typical performance specified at the antenna port for 10-6 BER.
The system gain is typically 1 dB greater for a BER of 10-3.
System Gain = maximum transmit power - receiver sensitivity
NA (Not Available)
Aprisa XE User Manual
300 | Specifications
Link Delays IC
Note: The default Modem Interleaver Mode setting is on for channel sizes of 250 kHz and greater and off
for channel sizes of 200 kHz and less (see ‘Modem Interleaver Mode’ on page 72).
Interleaver off
Channel size
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
25 kHz
NA
49.6 ms
39.4 ms
34.9 ms
NA
75 kHz
35.5 ms
19.0 ms
16.8 ms
13.6 ms
10.6 ms
100 kHz
28.8 ms
15.3 ms
12.7 ms
10.9 ms
8.2 ms
150 kHz
17.5 ms
10.1 ms
8.5 ms
7.1 ms
5.7 ms
200 kHz
15.9 ms
8.8 ms
7.3 ms
6.4 ms
5.1 ms
500 kHz
6.3 ms
3.5 ms
3.4 ms
3.2 ms
2.8 ms
1.0 MHz
3.8 ms
2.6 ms
2.3 ms
2.2 ms
2.1 ms
1.75 MHz
3.1 ms
2.3 ms
2.1 ms
2.0 ms
1.9 ms
3.5 MHz
2.6 ms
2.0 ms
1.8 ms
1.8 ms
1.7 ms
7.0 MHz
2.0 ms
1.7 ms
1.6 ms
1.6 ms
1.6 ms
14 MHz
NA
1.6 ms
1.5 ms
1.5 ms
1.5 ms
Interleaver on
Channel size
QPSK
16 QAM
32 QAM
64 QAM
128 QAM
25 kHz
NA
164.7 ms
127.7 ms
111.8 ms
NA
75 kHz
103.7 ms
53.2 ms
45.8 ms
36.4 ms
28.8 ms
100 kHz
85.3 ms
43.6 ms
35.3 ms
29.7 ms
21.4 ms
150 kHz
51.4 ms
26.8 ms
21.9 ms
18.6 ms
14.3 ms
200 kHz
45.8 ms
23.7 ms
19.3 ms
16.4 ms
12.3 ms
500 kHz
16.5 ms
9.3 ms
8.0 ms
6.9 ms
5.7 ms
1.0 MHz
8.8 ms
5.1 ms
4.3 ms
3.9 ms
3.5 ms
1.75 MHz
6.8 ms
4.1 ms
3.6 ms
3.2 ms
2.9 ms
3.5 MHz
5.1 ms
3.2 ms
2.8 ms
2.6 ms
2.4 ms
7.0 MHz
3.5 ms
2.4 ms
2.2 ms
2.1 ms
2.0 ms
14 MHz
NA
2.1 ms
1.9 ms
1.8 ms
1.8 ms
Notes
The end to end link delays are measured from E1 / T1 interface to E1 / T1 interface
The delay figures are typical and can vary when the system re-synchronizes
NA (Not Available)
Aprisa XE User Manual
Specifications | 301
Receiver Performance
Maximum input level
-20 dBm
Dynamic range
58 to 87 dB (at 10-6 BER)
depending on modulation type and channel size
C/I ratio
(carrier to interference ratio)
C/I ratio = CdB - IdB
Co-channel
better than 16 dB at QPSK
better than 20 dB at 16 QAM
better than 23 dB at 32 QAM
better than 27 dB at 64 QAM
better than 30 dB at 128 QAM
1st adjacent channel
better than -5 dB
2nd adjacent channel
better than -30 dB
Typical performance specified at the antenna port for 10-6 BER.
Notes
The dynamic range is typically 2 dB greater for a BER of 10-3.
Duplexers
Code
Frequency
Band
Option
A0
300 MHz
Standard
A1
300 MHz
A2
300 MHz
B0
TX / RX
Min Split
Passband
Lo Band
Hi Band
Mounting
9.45 MHz
2 MHz
330 - 400 MHz
330 - 400 MHz
External
Option 1
5 MHz
0.5 MHz
330 - 400 MHz
330 - 400 MHz
External
Option 2
20 MHz
3.5 MHz
330 - 400 MHz
330 - 400 MHz
External
400 MHz
Standard
9.45 MHz
2 MHz
400 - 470 MHz
400 - 470 MHz
External
B1
400 MHz
Option 1
5 MHz
0.5 MHz
400 - 470 MHz
400 - 470 MHz
External
B2
400 MHz
Option 2
20 MHz
3.5 MHz
400 - 470 MHz
400 - 470 MHz
External
C0
400 MHz
Standard
3 MHz
0.5 MHz
470 - 492 MHz
473 - 495 MHz
External
D0
600 MHz
Standard
45 MHz
7 MHz
620 - 715 MHz
620 - 715 MHz
Internal
E0
700 MHz
Standard
30 MHz
7 MHz
698 - 806 MHz
698 - 806 MHz
Internal
F0
800 MHz
Standard
40 MHz
7 MHz
805 - 890 MHz
805 - 890 MHz
Internal
G0
900 MHz
Standard
40 MHz
7 MHz
850 - 960 MHz
850 - 960 MHz
Internal
G1
900 MHz
Option 1
9 MHz
1.5 MHz
928 - 960 MHz
928 - 960 MHz
External
G2
900 MHz
Option 2
9 MHz
1 MHz
928 - 960 MHz
928 - 960 MHz
Internal
G3
900 MHz
Option 3
5.5 MHz
0.5 MHz
900 - 960 MHz
900 - 960 MHz
External
G4
900 MHz
Option 4
3.6 MHz
0.5 MHz
900 - 960 MHz
900 - 960 MHz
External
H0
1400 MHz
Standard
48 MHz
7 MHz
1350 - 1550 MHz
1350 - 1550 MHz
Internal
H1
1400 MHz
Option 1
23.5 MHz
7 MHz
1350 - 1550 MHz
1350 - 1550 MHz
Internal
K0
1800 MHz
Standard
47.5 MHz
14 MHz
1700 - 2100 MHz
1700 - 2100 MHz
Internal
I0
2000 MHz
Standard
91 MHz
14 MHz
1900 - 2300 MHz
1900 - 2300 MHz
Internal
J0
2500 MHz
Standard
74 MHz
14 MHz
2300 - 2700 MHz
2300 - 2700 MHz
Internal
J1
2500 MHz
Option 1
32 MHz
4 MHz
2314 - 2318 MHz
2346 - 2350 MHz
Internal
Notes
All duplexers are bandpass
Contact 4RF for other duplexer options
Aprisa XE User Manual
302 | Specifications
Interface Specifications
Ethernet Interface
General
Diagnostics
Interface
RJ-45 * 4 (Integrated 4-port switch)
Cabling
CAT-5 UTP, supports auto MDIX (Standard Ethernet)
Maximum line length
100 metres on cat-5 or better
Bandwidth allocation
n x 8 kbit/s up to maximum available.
n x 64 kbit/s is recommended for terminals with higher
channel size (> 500 kHz, 32 QAM).
Ethernet capacity
The ethernet capacity maximum is determined by the lesser
of the available radio link capacity or 50 Mbit/s.
Maximum packet size
‘Standard’ Ethernet packets: max 1518 octets
Tagged and double-tagged packets: max 1526 octets
Data buffer size
Up to 256 frames
Address table size
2048 IP addresses
WAN protocol
HDLC
Ethernet mode
10Base-T or 100Base-TX
Full duplex or half duplex
(Auto-negotiating and auto-sensing)
VLAN tagging
IEEE 802.1Q VLAN tagging
QoS
IEEE 802.1p
Ipv4 TOS DiffServ
Ipv6 traffic class
Spanning Tree
Forwards 802.1D Spanning Tree Protocol packets up to 1526
bytes in length.
Green LED
On: Ethernet signal received
Flashing: Indicates data traffic present on the interface
Note: Do not connect Power over Ethernet (PoE) connections to the Aprisa XE Ethernet ports as this will
damage the port.
Aprisa XE User Manual
Specifications | 303
QJET Quad E1 / T1 Interface
General
Standard
G.703 and G.704
Interface
RJ-45
Line termination impedance
E1 120 Ω balanced
T1 100 Ω balanced
Maximum line length
E1 typically up to 1.7 km (43 dB of loss at 1024 kHz in
standard 0.4 mm2 cable).
T1 typically up to 1.7 km (36 dB of loss at 772 kHz in
standard 0.4 mm2 cable).
Bandwidth allocation
Framed E1s require a link bandwidth of 2048 kbit/s.
Unframed E1s require a link bandwidth of 2088 kbit/s.
Framed T1s require a link bandwidth of 1544 kbit/s.
Unframed T1s require a link bandwidth of 1584 kbit/s.
Line code
E1 HDB3 or AMI
T1 B8ZS or AMI
Diagnostics
Tx Waveform Shaper
(T1 only)
0 ~ 133 ft
133 ~ 266 ft
266 ~ 399 ft
399 ~ 533 ft
533 ~ 655 ft
Stability
±50 ppm
Jitter performance
G.823 (sections 2 & 3)
Green LED
On: Interface is operational and in service
Off: No 2 Mbit/s input signal
Flashing: The interface loopback is active.
Yellow LED
On: Alarm
Off: No alarm
Aprisa XE User Manual
304 | Specifications
Q4EM Quad 4 Wire E&M Interface
General
Analogue
Signalling
Diagnostics
Audio
64 kbit/s (PCM A-Law as per ITU G.711)
32, 24 and 16 kbit/s (ADPCM as per ITU G.726 and ANSI
TI.303)
E&M signalling
8 kbit/s per port
Maximum line length
400 metres
Transmission performance
characteristics
ITU G.712 E4 for an operating level range of -14 dBr to
+4 dBr for a G.711 64 kbit/s coded channel
Input level range
-14.0 dBr to +4.0 dBr in 0.5 dB steps
Output level range
-14.0 dBr to +4.0 dBr in 0.5 dB steps
Default output level
0 dBr
Default input level
0 dBr
Maximum level
+3.14 dBm0
Port impedance
600 Ω
Return loss
better than 25 dB over the frequency range 200 - 3600 Hz
Transformer isolation
3.88 kV
End to end gain
Frequency response
0 dB ± 0.1 dB (300-3000 Hz)
0 dB ± 0.5 dB (250-3400 Hz)
Audio line protection
Secondary protection
Signal to total distortion
> 30 dB (0 dBm0 to -30 dBm0)
> 22 dB (-45 dBm0)
E&M
Mode independent (external power supply / ground
reference required)
Pulse distortion
4:1 multiplexed < 2.250 ms
Non-multiplexed 250 µs
M loop current
5.0 to 6.5 mA (constant current)
M detection voltage
9 VDC
M maximum voltage
60 VDC
E circuit impedance
45 Ω closed
> 100 kΩ open
Maximum E circuit current
100 mA
E maximum voltage
60 V
E&M circuit protection
E: Current limited to 120 mA, overvoltage to 350 V
M: Current limited to 6.5 mA, overvoltage to 100 V
Green LED
Off: No external source applied to M wire
On: External source applied to M wire
Flashing: The interface loopback is active
Yellow LED
Off: E wire relay contact open
On: E wire relay contact closed
Aprisa XE User Manual
Specifications | 305
DFXO Dual Foreign Exchange Office Interface
General
Analogue
Audio
64 kbit/s (PCM as per ITU G.711)
32, 24 and 16 kbit/s (ADPCM as per ITU G.726 and ANSI
TI.303)
Signalling allocation
8 or 32 kbit/s allocated for CAS (multiplexed / non
multiplexed)
Companding
A-Law or µ-Law
Maximum line length
600 metres (2000 feet) on 0.4 mm / 26 AWG copper pair
Calling line ID (CLI)
Support provided for ETSI: EN 300 659-1 & 2 and BT: SIN 227
and 242
Fax
Conforms to G3 standard for 64 kbit/s PCM and 32 kbit/s
ADPCM compression
Transmission performance
characteristics
ITU G.712 E2 for an operating level range of -6 dBr to +1 dBr
for a G.711 64 kbit/s coded channel
Input level range
-10 dBr to +1.0 dBr in 0.5 dB steps
Output level range
-10 dBr to +1.0 dBr in 0.5 dB steps
Default Input level
-4.0 dBr
Default Output level
-1.0 dBr
Maximum level
+3.14 dBm0
Line impedance / Hybrid
balance impedance options
600 Ω
900 Ω
600 Ω + 2.16 µF
900 Ω + 2.16 µF
270 Ω + 750 Ω || 150 nF (TBR-21)
220 Ω + 820 Ω || 120 nF (TN12)
370 Ω + 620 Ω || 310 nF (BT3)
320 Ω + 1050 Ω || 210 nF (BT Network)
200 Ω + 680 Ω || 100 nF (China)
Return Loss
better than 12 dB 300 Hz to 600 Hz
better than 15 dB 600 Hz to 3400 Hz
Trans hybrid loss
better than 13 dB 300 Hz to 3400 Hz
better than 17 dB 500 Hz to 2500 Hz
(with matched external line and hybrid balance impedance)
Common mode rejection
ratio
better than 40 dB 50 Hz to 3800 Hz
Echo Canceller
provides up to 64 ms of echo cancellation
reduces the echo by more than 15 dB at an input signal level
of 10 dBm0.
better than 46 dB 600 Hz to 3400 Hz
Aprisa XE User Manual
306 | Specifications
Signalling
DTMF dialing
Standard DTMF dialing over the voice channel
Pulse dialing
Transparent decadic signalling at 7 - 14 PPS with break
period limits of 60 - 73 %
Pulse distortion
4:1 multiplexed < 2.250 ms
Non-multiplexed 250 µs
Reversals
Line polarity reversal detection
Loop current limit
maximum of 60 mA with Loop Current Limiter On
maximum of 160 mA with Loop Current Limiter Off
Metering level sensitivity
12 kHz / 16 kHz billing tone detection with a selectable
level sensitivity of -17dBm to -40 dBm in 1dB steps into 200
Ω
(60 mV rms to 5 mV rms into 200 Ω).
Metering level maximum
The maximum level of metering signal the DFXO can tolerate
without voice band interference is 0.8 Vrms into 200 Ω.
Loop resistance on-hook
>1 MΩ
Ringing detection threshold
Three selectable options of 16 Vrms, 26 Vrms and 49 Vrms ±
20 %.
Ringing detection frequency
15 to 50 Hz sine wave
Ringing input impedance
Two selectable options of >1 MΩ and >12 kΩ
Ringing DC offset range
tolerance
0 to -75VDC
Ringing input voltage
maximum
up to 100 Vrms
Ringing cadence limits
Ringing ON:
Ringing OFF:
min
270 ms
180 ms
max
10 secs
4 secs
Ringing cadence distortion
< 40 ms cadence error on both ring and silent periods
Physical
Physical interface
Dual RJ-45 per port (1 line port, 1 monitor port)
Diagnostics
Green LED
Off: Interface operational but not in service
On: Interface in service
Flashing: Cadenced ringing on line
Yellow LED
Off: No interface alarm
On: Interface alarm
Flashing: The interface loopback is active
Aprisa XE User Manual
Specifications | 307
DFXS Dual Foreign Exchange Subscriber Interface
General
Analogue
Audio
64 kbit/s (PCM as per ITU G.711)
32, 24 and 16 kbit/s (ADPCM as per ITU G.726 and ANSI
TI.303)
Signalling Allocation
8 or 32 kbit/s allocated for CAS (multiplexed / non
multiplexed)
Compression coding
A-Law or µ-Law
Maximum line length
600 metres (2000 feet) on 0.4 mm / 26 AWG copper pair
Calling line ID (CLI)
Support provided for ETSI: EN 300 659-1 & 2 and BT: SIN 227
and 242
Fax
Conforms to G3 standard for 64 kbit/s PCM and 32 kbit/s
ADPCM compression
Transmission performance
characteristics
ITU G.712 E2 for an operating level range of -6 dBr to
+2.0 dBr for a G.711 64 kbit/s coded channel
Input level range
-9.0 dBr to +2.0 dBr in 0.5 dB steps
Output level range
-9.5 dBr to +2.5 dBr in 0.5 dB steps
Default Input level
+1.0 dBr
Default Output level
-6.0 dBr
Maximum level
+3.14 dBm0
Line impedance / Hybrid
balance impedance options
600 Ω
900 Ω
600 Ω + 2.16 µF
900 Ω + 2.16 µF
220 Ω + (820 Ω || 120 nF) (TN12)
270 Ω + (750 Ω || 150 nF) (TBR21)
370 Ω + (620 Ω || 310 nF) (BT3)
Return Loss
better than 12 dB 300 Hz to 600 Hz
better than 15 dB 600 Hz to 3400 Hz
Trans hybrid loss
better than 13 dB 300 Hz to 3400 Hz
better than 17 dB 500 Hz to 2500 Hz
(with matched external line and hybrid balance impedance)
Common mode rejection
ratio
better than 40 dB 50 Hz to 3800 Hz
better than 46 dB 600 Hz to 3400 Hz
Aprisa XE User Manual
308 | Specifications
Signalling
Physical
Diagnostics
Feed voltage output
-48 V (160 + 160 Ω voltage source current limited)
Loop current limit
35 mA ± 10 %.
Seize signal
Loop start only (no ground start)
Loop detect threshold
9 to 12 mA (step function between on hook and off hook)
Loop non-seizure current
> 6 mA (step function between on hook and off hook)
Loop release threshold
> 4 mA
DTMF dialing
Standard DTMF dialing over the voice channel
Pulse dialing
Transparent decadic signalling at 7 - 14 PPS with break
period limits of 60 - 73 % (with loop current > 23 mA)
Pulse distortion
4:1 multiplexed < 2.250 ms
Non-multiplexed 250 µs
Reversals output
Line polarity reversal output (optional)
Metering output frequency
12 kHz / 16 kHz ± 0.5 %.
Metering output voltage
Four selectable output voltages of 100 mV, 200 mV, 300 mV
and 400 mV rms into 200 Ω ± 20 % sourced via the Line
Impedance setting but limited to a maximum open circuit
voltage of 1 Vrms.
Metering output distortion
Billing tone total distortion < 5 %.
Ringer waveform
Sinusoidal with a maximum total distortion of 10% (into 3
REN load)
Ringer voltage (open circuit)
Five selectable ringer output voltages sourced via an
internal ringing resistance of 178 per port.
The ringing output is a composite balanced AC ringing
voltage with a differential DC offset voltage.
60 Vrms + 0 VDC
55 Vrms + 10 VDC
50 Vrms + 18 VDC
45 Vrms + 22 VDC
40 Vrms + 24 VDC
Both the DC and AC components have a tolerance of ± 5%.
Ringer output frequency
Three selectable options of 17, 25 or 50 Hz ± 5%
Ringer output power
60 Vrms source into a load of 2 REN
45 Vrms source into a load of 3 REN
(1 REN 6930
F)
Ring trip
Ring trip will ocurr in < 150 ms following DC loop of > 20 mA
Ring trip immunity
Ring trip will not ocurr if the DFXS outputs ringing into a
load of 500 in series with 4.4 F or less.
Physical interface
Dual RJ-45 per port (1 line port, 1 monitor port)
Line protection
Secondary protection (4RF recommends the use of external
primary protection in lightning prone areas)
Green LED
Off: Interface operational but not in service
On: Interface in service
Flashing: Cadenced ringing on line
Yellow LED
Off: No interface alarm
On: Interface alarm
Flashing: The interface loopback is active
Aprisa XE User Manual
Specifications | 309
QV24 Quad V.24 Serial Data Interface
General
Interface
ITU-T V.24 / EIA/TIA RS-232E
Interface direction
DCE only
Bandwidth allocation
8 to 120 kbit/s in 8 kbit/s steps (dependent on rate
selected)
Control line allocation
8 kbit/s
Maximum line length
10 metres
Data clamp
Mark hold when out of sync.
Control line clamp
Off when loss of sync.
Clock
Internally generated from 2.048 MHz system clock
(synchronized at both ends)
Transparent mode
Operation is completely transparent but limited to 0-600
bit/s
Standard mode data bits
7 or 8 bits
Standard mode parity
Transparent (enable / disable)
Standard mode stop bits
1 or 2 bits
Asynchronous Data rates
300, 600, 1200, 2400, 4800, 7200, 9600, 12800, 14400,
19200, 23040, 28800, 38400, 57600 and 115200 bit/s
Control signals
End-to-end
CTS to RTS, DSR to DTR
Diagnostics
Green LED
Indicates RX data traffic present
Yellow LED
Indicates TX data traffic present
Async
parameters
QV24S Quad V.24 Serial Data Interface
General
Interface
ITU-T V.24 / EIA/TIA RS-232E
Interface direction
DCE only
Bandwidth allocation
8 to 120 kbit/s in 8 kbit/s steps (dependent on rate
selected)
Control line allocation
8 kbit/s
Maximum line length
10 metres
Data clamp
Mark hold when out of sync.
Control line clamp
Off when loss of sync.
Synchronous Data rates
300, 600, 1200, 2400, 4800, 9600 and 19200 bit/s
Control signals
End-to-end
CTS to RTS
Diagnostics
Green LED
Indicates RX data traffic present
Yellow LED
Indicates TX data traffic present
Aprisa XE User Manual
310 | Specifications
HSS Single High Speed Synchronous Data Interface
General
Diagnostics
Interfaces
ITU-T V.35
ITU-T X.21
EIA RS-449
EIA RS-530
Bandwidth allocation
8 to 2048 kbit/s in 8 kbit/s steps (dependent on rate
selected)
8 kbit/s for control lines
Maximum line length
3 metres
Clock
Internally generated from 2.048 MHz system clock
(synchronized at both ends) on DCE to DCE mode.
Clock provided by external DCE when in DTE mode.
Remote DCE outputs clock-timed by incoming clock at DTE.
Top Green LED
On: Normal operation
Flashing: Loopback
Lower Green LED
On: Normal operation
External Alarm Interfaces
Alarm inputs
Alarm outputs
Overall
Detector type
Isolated current detectors
Detection current
5.0 to 6.5 mA (constant current)
Detection voltage
9 to 60 VDC or AC rms
Contact type
Isolated semiconductor relay type contacts
Maximum current
100 mA
Maximum voltage
0 to 60 VDC or AC rms
Ouput impedance
45 Ω closed
> 100 kΩ open
Latency
The latency for an alarm presented on an external alarm
input to the alarm being output on an external alarm output
is < 2 seconds
Auxiliary Interfaces
Management
Configuration and
management
Embedded web server and / or SNMP accessed via Ethernet
interface or across link
Test points
RSSI
Front panel test point for measuring the RSSI voltage
Aprisa XE User Manual
Specifications | 311
Power Specifications
AC Power Supply
Nominal
voltage
Input voltage
range
Maximum Power
input
Max VA
Frequency
115 VAC
103 - 127 Vrms
180 W
400 VA
47 - 63 Hz
230 VAC
207 - 254 Vrms
180 W
400 VA
47 - 63 Hz
Nominal voltage
Input voltage
range
Maximum Power
input
Maximum input
current
Recommended
DC breaker
rating
+12 VDC LP
10.5 to 18 VDC
53 W
5A
8A
±12 VDC
10.5 to 18 VDC
180 W
18 A
25 A
±24 VDC
20.5 to 30 VDC
180 W
8A
10 A
±48 VDC
40 to 60 VDC
180 W
4A
5A
DC Power Supply
Aprisa XE User Manual
312 | Specifications
Power Consumption
Terminal Type
Power Consumption (min – max)
Standard Aprisa XE 1+0 terminal
34 to 170 W Input power
(dependent on the transmitter output power, the interface cards
fitted and the power supply option)
Standard Aprisa XE 1+1 terminal
74 to 375 W Input power
(dependent on the transmitter output power, the interface cards
fitted, the number of trib switches and the power supply option)
Standard Aprisa XE HSD terminal
68 to 286 W Input power
(dependent on the transmitter output power, the interface cards
fitted and the power supply option)
Power Consumption Model
An Aprisa XE Power Consumption model program called XEpower is on the Aprisa XE CD. This program
shows the typical power consumption for any product configuration. Java 1.6 is required to be installed on
your PC to run this program.
Standard Aprisa XE 1+0 terminal – 48 VDC
These power consumption figures represent the typical power drawn by a single standard 1400 MHz 1+0
terminal measured at the input to a ± 48 VDC power supply.
Power Consumption (min – max)
40 to 150 W Input power (dependent on interface cards fitted
and transmitter output power level)
Terminal only:
TX power of + 20 dBm
44 W
TX power of + 25 dBm
54 W
TX power of + 30 dBm
61 W
TX power of + 35 dBm
64 W
Interface cards:
QJET four port E1 card
2.3 W (four ports operating)
Q4EM four port 4W E&M card
0.6 W (all states)
QV24 four port V.24 card
0.2 W (all states)
DFXO two port 2W FXO card
0.7 W (all states)
DFXS two port 2W FXS card
One DFXS card installed with both ports idle (on hook): 2.5 W
Plus:
1.9 W / line off-hook (200 ohm copper loop plus 450 ohm
telephone)
1.0 W / line ringing (60 Vrms 25Hz source via 100 ohm copper
loop into a 1 REN load)
1.5 W / line ringing (45 Vrms 25Hz source via 100 ohm copper
loop into a 3 REN load)
HSS single port high speed data
1.0 W (all states)
MHSB:
Tributary and RF switch
13 W not switched
25 W switched
Aprisa XE User Manual
Specifications | 313
Low Power Aprisa XE 1+0 terminal – 12 VDC
These power consumption figures represent the typical power drawn by a single low power 1400 MHz 1+0
terminal measured at the input to a low power +12 VDC power supply.
Power Consumption (min – max)
34 to 53 W Input power (dependent on interface cards fitted and
transmitter output power level)
Terminal only:
TX power of + 20 dBm
34 W
TX power of + 24 dBm
40 W
Interface cards:
QJET four port E1 card
1.9 W (four ports operating)
Q4EM four port 4W E&M card
0.53 W (all states)
QV24 four port V.24 card
0.15 W (all states)
DFXO two port 2W FXO card
0.56 W (all states)
DFXS two port 2W FXS card
One DFXS card installed with both ports idle (on hook): 2.1 W
Plus:
1.6 W / line off-hook (200 ohm copper loop plus 450 ohm
telephone)
0.8 W / line ringing (60 Vrms 25Hz source via 100 ohm copper
loop into a 1 REN load)
1.2 W / line ringing (45 Vrms 25Hz source via 100 ohm copper
loop into a 3 REN load)
HSS single port high speed data
0.85 W (all states)
Aprisa XE User Manual
314 | Specifications
Protection System Specifications
MHSB Protection
MHSB switches
RF switch
Tributary switch
Switching time
< 25 ms from detection of alarm condition
Switch hysteresis
30 seconds (to prevent switching on short alarm transients)
RF path restore time
< 10 seconds
TX relay / cable loss
1.0 dB
RX splitter / cable loss
4.0 dB
Total system loss
System gain reduced by a maximum of 5 dB
Ports
HSD Protection
TX path
TX relay / cable loss
Switching times
Transmit path
< 25 ms from detection of alarm condition
Receive path
Hitless
1.0 dB
Aprisa XE User Manual
Specifications | 315
General Specifications
Environmental
Operating range
-10 to +50˚ C
Storage range
-20 to +70˚ C
Humidity
Maximum 95% non-condensing
Acoustic noise emission
59 dBA (A-weighted Sound Power Level)
Mechanical
Height
Standard terminal
2 U high (internal duplexer)
3 – 4 U high (depending on external duplexer type)
MHSB terminal
6 U high (internal duplexer)
7 – 8 U high (depending on external duplexer type)
HSD terminal
4 U high (internal duplexer)
6 – 8 U high (depending on external duplexer type)
Width
19-inch rack mount
434 mm (without mounting brackets attached)
483 mm (with mounting brackets attached)
Depth
372 mm
Colour
Pure black
Weight
Standard terminal
8 kg (internal duplexer)
9 - 12 kg (depending on external duplexer type)
MHSB terminal
25 kg (internal duplexer)
26 – 29 kg (depending on external duplexer type)
HSD terminal
17 kg (internal duplexer)
19 – 24 kg (depending on external duplexer type)
ETSI Compliance
Radio
EN 301 751, EN 300 630
EN 302 217 Parts 1, 2.1, and 2.2
EMI/EMC
EN 301 489 Parts 1 & 4
Safety
EN 60950
CSA 253147 applicable for AC, 48 VDC and 24 VDC product
variants
Environmental
ETS 300 019 Class 3.2
Aprisa XE User Manual
Product End Of Life | 317
19. Product End Of Life
End-of-Life Recycling Programme (WEEE)
The WEEE Directive concerns the recovery, reuse, and recycling of electronic and electrical equipment.
Under the Directive, used equipment must be marked, collected separately, and disposed of properly.
4RF Limited has implemented an end-of-life recycling programme to manage the reuse, recycling, and
recovery of waste in an environmentally safe manner using processes that comply with the WEEE Directive
(EU Waste Electrical and Electronic Equipment 2002/96/EC).
The WEEE Symbol Explained
This symbol appears on Electrical and Electronic Equipment (EEE) as part of the WEEE (Waste EEE)
directive. It means that the EEE may contain hazardous substances and must not be thrown away with
municipal or other waste.
WEEE Must Be Collected Separately
You must not dispose of electrical and electronic waste with municipal and other waste. You must
separate it from other waste and recycling so that it can be easily collected by the proper regional WEEE
collection system in your area.
YOUR ROLE in the Recovery of WEEE
By separately collecting and properly disposing of WEEE, you are helping to reduce the amount of WEEE
that enters the waste stream.
One of the aims of the WEEE directive is to divert EEE away from landfill and encourage recycling.
Recycling EEE means that valuable resources such as metals and other materials (which require energy to
source and manufacture) are not wasted. Also, the pollution associated with accessing new materials and
manufacturing new products is reduced.
EEE Waste Impacts the Environment and Health
Electrical and electronic equipment (EEE) contains hazardous substances which have potential effects on
the environment and human health. If you want environmental information on the Aprisa XE terminal,
contact us (on page 19).
Aprisa XE User Manual
Abbreviations | 319
20. Abbreviations
ADC
Analogue to Digital Converter
H/W
Hardware
ADPCM
Adaptive Differential Pulse Code
Modulation
IC
Integrated Circuit
IF
Intermediate Frequency
ADSL
Asymmetrical Digital Subscriber
Line
IP
Internet Protocol
AGC
Automatic Gain Control
I/O
Input/Output
AMP
Amplifier
ISP
Internet Service Provider
BER
Bit Error Rate
kbit/s
Kilobits per second
CAS
Channel Associated Signalling
kHz
Kilohertz
CPE
Customer Premises Equipment
LAN
Local Area Network
CLI
Calling Line Identification
LED
Light Emitting Diode
DAC
Digital to Analogue Converter
LOS
Loss of Signal
dB
Decibels
mA
Milliamps
dBc
Decibels relative to carrier power
MAC
Media Access Control
dBm
Decibels relative to 1 mW
Mbit/s
Megabits per second
dBr
Decibels
relative
to
the
transmission reference point
MHSB
Monitored Hot Standby
MHz
Megahertz
DCE
Data Communications Equipment
MIB
Management Information Base
DTE
Data Terminal Equipment
MTBF
Mean Time Between Failures
DTI
Digital Trunk Interface
MTTR
Mean Time To Repair
E&M
Ear and Mouth
ms
milliseconds
EMC
Electro-Magnetic Compatibility
NFAS
EMI
Electro-Magnetic Interference
Not Frame Alignment Signal (E1
frame)
ESD
Electro-Static Discharge
NMS
Network Management System
ETSI
European
Telecommunications
Standards Institute
OSI
Open Systems Interconnection
PABX
FAS
Frame
frame)
Private
Exchange
PBX
Private Branch Exchange
FEC
Forward Error Correction
PC
Personal Computer
FFE
Feed Forward Equalizer
PCM
Pulse Code Modulation
F/W
Firmware
PCA
Printed Circuit Assembly
FXO
Foreign Exchange Office
PLL
Phase Locked Loop
FXS
Foreign Exchange Subscriber
POP
Point of Presence
GSM
Global
System
communications
POTS
Plain Old Telephone Service
ppm
Parts Per Million
PSTN
Public
Switched
Network
PMR
Public Mobile Radio
Alignment
Signal
for
(E1
Mobile
HSC
Hardware Software Compatibility
HSS
High-Speed Synchronous Serial
Aprisa XE User Manual
Automatic
Branch
Telephone
QAM
Quadrature Amplitude Modulation
QPSK
Quadrature Phase Shift Keying
RAI
Remote Alarm Indicator
RF
Radio Frequency
RoHS
Restriction
Substances
of
RSSI
Received
Indication
Signal
RX
Receiver
SNMP
Simple Network
Protocol
SNR
Signal to Noise Ratio
SWR
Standing Wave Ratio
TCP/IP
Transmission
Control
Protocol/Internet Protocol
Hazardous
Strength
Management
TCXO
Temperature
Crystal Oscillator
Compensated
TETRA
Terrestrial Trunk Radio
TFTP
Trivial File Transfer Protocol
TMR
Trunk Mobile Radio
TX
Transmitter
UTP
Unshielded Twisted Pair
VAC
Volts AC
VCO
Voltage Controlled Oscillator
VDC
Volts DC
VoIP
Voice over Internet Protocol
WEEE
Waste Electrical and Electronic
Equipment
Acknowledgments and Licensing | 321
21. Acknowledgments and Licensing
The Aprisa XE product software runs the GNU Linux Operating System and incorporates several other
packages in accordance with the free software philosophy.
The following list identifies the licensed software used:
BusyBox
Description: Tiny versions of common UNIX utilities
Reference: http://busybox.net/
License Type: GNU General Public License (GPL)
DropBear SSH Server
Description: Small and secure SSH Server
Reference: http://matt.ucc.asn.au/dropbear/
License Type: MIT Style License
GoAhead WebServer 2.1
Description: Embedded Web Server
Reference: http://webserver.goahead.com/
License Type: Private License
Linux Kernel
Description: Linux Kernel version 2.4.26
Reference: http://www.kernel.org/
License Type: GNU General Public License (GPL)
Net-SNMP
Description: Various tools relating to SNMP
Reference: http://www.net-snmp.org/
License Type: CMU/UCD and BSD License
uClibc
Description: C library for embedded Linux systems
Reference: http://uclibc.org/
License Type: GNU Lesser General Public License (LGPL)
U-Boot
Description: Bootloader
Reference: http://u-boot.sourceforge.net/
License Type: GNU General Public License (GPL)
Aprisa XE User Manual
322 | Acknowledgments and Licensing
Software Licensed Under the GPL
Some of the above packages licensed under the GPL have been modified by 4RF Limited. The copyright
holders of these modified packages (including 4RF Limited) agree to them being distributed under the
terms of the General Public License.
Copies of the GNU General Public License (GPL) and Lesser General Public License (LGPL) can be obtained
from the Free Software Foundation Inc, 59 Temple Place - Suite 330, Boston, MA, 02111-1307, USA. Plain
text copies of these licenses can also be found at:
http://www.gnu.org/licenses/gpl.txt
http://www.gnu.org/licenses/lgpl.txt
If you would like a copy of the GPL source code used in this product on a CD, please send US$50.00 (to
cover the preparation of the CD and transport costs) to 4RF Limited, PO Box 13-506, Wellington, New
Zealand.
Software Licensed Under Other Licenses
The following copyright notices are included for packages not covered by the GPL:
Dropbear SSH Server (MIT License)
Dropbear—a SSH2 server
Copyright © 2002, 2003 Matt Johnston
All rights reserved
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and
associated documentation files (the ‘Software’), to deal in the Software without restriction, including
without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the
following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial
portions of the Software.
THE SOFTWARE IS PROVIDED ‘AS IS’, WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM,
DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
SOFTWARE.
Aprisa XE User Manual
Acknowledgments and Licensing | 323
Net-SNMP
Part 1: CMU/UCD (BSD like)
Copyright © 2001-2003, Networks Associates Technology, Inc
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided
that the following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of conditions and the
following disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the Networks Associates Technology, Inc nor the names of its contributors may be
used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ‘AS IS'' AND ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Part 2: Networks Associates Technology, Inc. (BSD)
Copyright © 2001-2003, Networks Associates Technology, Inc
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided
that the following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of conditions and the
following disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the Networks Associates Technology, Inc nor the names of its contributors may be
used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ‘AS IS'' AND ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Aprisa XE User Manual
324 | Acknowledgments and Licensing
Part 3: Cambridge Broadband Ltd (BSD)
Portions of this code are copyright © 2001-2003, Cambridge Broadband Ltd.
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided
that the following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of conditions and the
following disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
The name of Cambridge Broadband Ltd. may not be used to endorse or promote products derived from this
software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER ‘AS IS'' AND ANY EXPRESS OR IMPLIED
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER BE
LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Part 4: Sun Microsystems, Inc. (BSD)
Copyright © 2003 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara,
California 95054, U.S.A. All rights reserved.
Use is subject to license terms below.
This distribution may include materials developed by third parties.
Sun, Sun Microsystems, the Sun logo and Solaris are trademarks or registered trademarks of Sun
Microsystems, Inc. in the U.S. and other countries.
Redistribution and use in source and binary forms, with or without modification, are permitted provided
that the following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of conditions and the
following disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the Sun Microsystems, Inc. nor the names of its contributors may be used to endorse
or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ‘AS IS'' AND ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Aprisa XE User Manual
Acknowledgments and Licensing | 325
Part 5: Sparta, Inc. (BSD)
Copyright © 2003-2004, Sparta, Inc
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided
that the following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of conditions and the
following disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
Neither the name of the Networks Associates Technology, Inc nor the names of its contributors may be
used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS ‘AS IS'' AND ANY EXPRESS
OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
GoAhead WebServer (Private License)
GoAhead WebServer
Copyright (c) 2000 GoAhead Software, Inc. All Rights Reserved
Aprisa XE User Manual
Commissioning Form | 327
22. Commissioning Form
Aprisa XE User Manual
Index | 329
23. Index
2 wire
105
4 wire
102
AC power supply
access rights
accessory kit
AIS
alarms
alarm summary
clearing alarms
E1 / T1 alarm conditions
external
history
identifying causes
interface alarms
saving history
termination
types
A-law
antennas
aligning
checking polarization
corner reflector
directional antennas
installing
parabolic
selection and siting
siting
yagi
attenuators
38
63
19
250
242
247
250
33
244
248
246
245
33
273
110
197
197
23
21, 22
32
21
21
23
22
41
balun transformer
basic terminal settings
bench setup
BER
brownout recovery module
browser cache, clearing
256
72
41
203
39
222
cabling
accessory kit
19
coaxial feeder
24, 41
for HSD
189
for MHSB
183
shielded
262
cache, clearing
221, 222
CAS
110, 159, 160, 161, 162
Castle Rock
83
CD contents
18
clock source
setting for
100, 131
compatibility of interfaces
156
configuration files
224
configuration, saving
87, 153
constellation analyser
205
corner reflector antenna
23
country specific settings
283
cross connections
creating
150
deleting
155
drop and insert
152
point to point
150
printing
154
saving configurations
153
selecting timeslots
164
sending configurations
153
Symmetrical Connection Wizard
174
cross connections application
about
145
ethernet capacity
148
getting configurations
149
installing
144
required system configuration for
143
toolbar
147
total assigned link capacity
145
user capacity
148
DC power supply
DCD mode
declaration of conformity
DFXO interface card
country specific settings
cross connections for
Aprisa XE User Manual
35
135
iii
118
283
169
330 | Index
interface connections for
port settings for
signalling for
DFXS interface card
country specific settings
cross connections for
interface connections for
port settings for
signalling for
directional antennas
Drop & Insert capacity
DSR DTR mode
duplexer parameters
262
118
169
110
283
169
261
110
169
21, 22
146
134
77
E&M interface
E1
alarm conditions
framed
unframed
earthing
environmental requirements
error counters
Ethernet
capacity
port status
Quality of Service
VLAN tagging
exchange end
external alarms
configuring
inputs
mapping
outputs
102
250
158, 159
158
24, 26, 41
25
203
148
98
94
91
118
79
79
81
81
180
gateway
factory default
62
handshaking
DCD mode
135
DSR DTR mode
134
RTS CTS mode
133
hardware
accessory kit
19
installing
31, 32
hitless
188
HSD
188
cabling
189
configuring terminals
191
IP addresses
190
HSS clocking
clocking types
137
cloud mode
141
internal clocking
137
pass-through clocking
137
pipe mode
138
primary/secondary master clocking
137
synchronous clock selection modes
136
HSS interface card
131
cross connections for
172
handshaking
133
interface connections for
263
port settings for
131
humidity
25
fade margin
fault finding
feeder cables
framed mode
framed modes
PCM30C mode
PCM31C mode
T1 ESF modes
T1 SF modes
frequency bands
frequency bands ETSI
front panel
connections
indicators
tributary switch
202
201, 239, 251
24
158
159
159
161, 162
160
27
285
29
29
image files
updating table of
in-service commissioning
installation
interface cabling
interface cards
before installing
configuring
installing
port settings
summary
types
interface connections
DFXO
Aprisa XE User Manual
226
230
195
31, 33
34
234
90
236
90
89
30
255
262
Index | 331
DFXS
Ethernet
HSS
Q4EM
QJET
QV24
QV24S
interface pinouts
HSS
interface traffic direction
interfaces, compatibility
IP address
factory defaults
network
terminal
understanding
261
257
263
258
256
271
271
263
255
156
62
52
73
51
Java
clearing cache
requirement for
221
18, 47, 143
clearing alarms for
187
configuring radios for
184
configuring the terminals
186
front panel
RF protection switch ................... 181
hot stand-by
179
IP addressing
184
monitored hot stand-by
179
mounting
185
power supply
183
slave tributary switch
182
standby mode
181
tributary switch
front panel ............................... 180
MIB
saving
87
minor alarms, mapping
81
modify user group
63
mounting kit
19
operating temperature
25
LEDs
identifying colours
248
interface
256, 257, 258, 261, 262, 263
RF protection switch
182
tributary protection switch
181
lightning protection
26
link budget
24
link capacity, assigned
146
link performance
201, 205
LOF
250
logging in
SuperVisor
58
Loop interface circuits
105
loopbacks
about
239
interface lookbacks
240
timeslot loopbacks
241
LOS
250
maintenance
major alarms, mapping
management
ethernet capacity
MHSB
cabling
211
81
148
179
183
passwords
changing
65
path planning
21
path propagation calculator
21
PCM modes
158, 159, 160, 161, 162
performance, of link
201, 205, 206
performance, save history
207
pinouts
262
DFXS
261
Ethernet
257
Q4EM
258
QJET
256
QV24
271
QV24S
271
Synchronous cable assemblies
264
POTS
105, 110, 118
power
AC power
38
DC cabling
36
DC power
35
power supply
25, 35
powering up
196
protected terminals
HSD
188
MHSB
179
Aprisa XE User Manual
332 | Index
Q4EM interface card
cross connections for
168
E&M signalling types
259
interface connections for
258
port settings for
102
QJET interface card
cross connections for
157
interface connections for
256
modes
158, 159, 160, 161, 162
port settings for
100
Quality of Service (QoS)
94
QV24 interface card
126, 127
baud rate
170
cross connections for
170
interface connections for
271
port settings for
126, 127
QV24S interface card
128
interface connections for
271
port settings for
128
rack space
RAI
rebooting the terminal
receiver
RF protection switch
front panel
LEDs
RF settings
modem performance
RS-449 synchronous data
RS-530 synchronous data
RSSI
alarm threshold
aligning the antennas
RTS CTS mode
31
250
231
28
181
182
67
70
131
131
78
199
133
MIB details
setting access controls
setting trap destinations
viewing traps
Space Diversity
specifications
auxiliary interfaces
DFXO interface
DFXS interface
environmental
ethernet interface
ETSI
external alarms interface
general
HSS interface
MHSB
Q4EM interface
QJET interface
QV24 interface
QV24s interface
static damage, avoiding
storage temperature
subnet mask
factory default
subscriber end
SuperVisor
logging into
logging out
opening page
PC requirements for
PC settings for
Surveyor
syslog
error logging
remote logging
system performance specifications
ETSI
86
84
85
86
188
285
308
303
305
313
300
313
308
313
308
312
302
301
307
307
236
25
62
110
57
58
59
60
47
48
21
251
251
253
285
safety earth
setup menu
COM port settings
Hyperterminal
setup basic settings
signalling mode
slots
configuring
terminal
SNMP
T1
40
44
44
55
169
238
30
83
alarm conditions
framed
unframed
temperature
terminal
alarm summary
applying power
clocking
earthing
installing
logging into
Aprisa XE User Manual
250
158, 160, 161, 162
158
25
242
196
74
26, 40, 41
31
58
Index | 333
logging out
modules
near and far, explained
operating conditions
power supplies
rebooting
upgrading
terminal emulator
test equipment
TFTP server
timed reboot
timeslots
PCM modes
selecting
tools
traffic direction of interfaces
tranformer, Balun
transmitter
tributary switch
LEDs
troubleshooting
59
28
51
25
35
231
224
87
204
219
231
X.21 synchronous data
159
164
31
255
256
28
181
239
unframed mode
upgrading the terminal
uploading system files
user ethernet capacity
users
access rights
adding
changing passwords
deleting
disabling
saving user information
session details
user groups
view user group
158
224
148
63
63
65
64
64
64
65
63
63
V.24
serial data
V.35 synchronous data
126, 127, 128
131
web browser cache, clearing
WEEE
222
315
Aprisa XE User Manual
131

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Doug.Connor
Create Date                     : 2012:07:26 13:35:13+12:00
Modify Date                     : 2012:08:01 13:33:48-07:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2012:08:01 13:33:48-07:00
Creator Tool                    : Microsoft® Office Word 2007
Format                          : application/pdf
Title                           : Aprisa XE User Manual
Creator                         : Doug.Connor
Document ID                     : uuid:81bb271e-1015-4e9a-856d-3450ad4e5bad
Instance ID                     : uuid:51290228-1dc4-461f-991e-22ab53797911
Producer                        : Microsoft® Office Word 2007
Page Count                      : 153
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UIPN0700AAAA0000A

Navigation menu