ABB Enterprise Software 2411 2.4 GHz 802.11n High Power Mini-PCI Card User Manual 6310 6320 Guide
Tropos Networks, Inc. 2.4 GHz 802.11n High Power Mini-PCI Card 6310 6320 Guide
Users Manual
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 ii
Copyright Notice
©2003-2008 Tropos Networks, Inc. All rights reserved. Tropos and PWRP are registered trademarks of Tropos
Networks, Inc. Tropos Networks, MetroMesh, AMCE, TMCX, SABRE, CMDP, MESM and Metro-Scale Mesh
Networking Defined are trademarks of Tropos Networks, Inc. Loctite is a registered trademark of Loctite Corporation,
USA. All other brand or product names are trademarks or registered trademarks of their respective holder(s).
Information contained herein is subject to change without notice. The only warranties for Tropos products and
services are set forth in the express warranty statements accompanying such products and services. Nothing herein
should be construed as constituting an additional warranty. Tropos shall not be liable for technical or editorial errors or
omissions contained herein.
This product includes technology protected by U.S. Patents 6,704,301; 6,965,575; 7,016,328; 7,031,293; and
7,058,021.
FCC Notice to Users and Operators
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in
which case the user will be required to correct the interference at his own expense. If this equipment does cause
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to correct the interference by using one of the following measures:
Reorient or relocate the receiving antenna.
Increase separation between the equipment and receiver.
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician.
This Part 15 radio device operates on a non-interference basis with other devices operating at this frequency. Any
changes or modification to said product not expressly approved by Tropos Networks could void the user's authority to
operate this device.
Industry Canada
Notice to users and operators:
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des
réglements d’équipement. L’opération est sujette aux deux conditions suivantes : (1) cet dispositif peut ne pas causer
l'interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l'interférence qui
peut causer l’opération peu désirée.
Warning
It is illegal to modify the construction of this product. Modifying the operating frequency or
enhancing the transmit output power through the use of external amplifiers or other
equipment is specifically disallowed by the “Telecommunications Act.”
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 iii
Warning
This device is for outdoor or indoor use with conditions that no harmful interference to
authorized radio stations results from the operation of this device. This device shall not
influence aircraft security and/or interfere with legal communications as defined in the
“Telecommunications Act.” If this device is found to cause interference, the operator of this
equipment shall cease operating this device immediately until no interference is achieved.
European Union WEEE Notice
It is important for users of this equipment to participate in reuse, recycling, and other forms of recovery. The potential
effects on the environment and human health as a result of the presence of hazardous substances in electrical and
electronic equipment are a waste of natural resources and cause pollution.
For EU member countries, this symbol means: Do not dispose of this equipment as unsorted
municipal waste. This equipment must be collected separately.
The return and collection of this product has not been defined at this time, please contact Tropos
Networks for return and/or collection.
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 iv
European Community Language Versions of Informal Statement for
Inclusion in User Information
The following statements are in accordance with Article 6.3 of Directive 1999/5/EC.
5320
5320
5320
5320
5320
5320
5320
5320
5320
5320
5320
5320
5320
5320
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
6320
6310
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 v
STOP!! STOP!! STOP!! STOP!!
READ THIS FIRST!
Important Safety Instructions
The exclamation point within an equilateral triangle is intended to alert the user
to the presence of important operating and maintenance (servicing) instructions
in the literature accompanying the product.
The lightning flash with an arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to constitute a
risk of electric shock to persons.
Caution
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not defeat the safety purpose of the grounding.
Only use attachments/accessories specified by the manufacturer.
Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damage in any way, such as power-supply cord or plug is
damaged, liquid has been spilled on objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 vi
Warning
Risk of personal injury or death when installing this device!
There is a risk of personal injury or death if the router antennas come near
electric power lines. Carefully read and follow all instructions in this manual. By
nature of the installation, you may be exposed to hazardous environments and
high voltage. Use caution when installing the outdoor system.
This apparatus must be connected to earth ground.
Do not open the unit — risk of electric shock inside.
Risque d'électrocution. Ne pas ouvrir l'unité.
Caution
You are cautioned that any change or modification not expressly approved in this
manual could void your authority to operate this equipment.
Les changements et modifications, non expressément approuvés dans le présent
manuel, peuvent entraîner une interdiction d'utiliser cet appareil pour l'utilisateur.
Service
There are no user-serviceable parts inside. All service must be performed by
qualified personnel.
Vous ne devez pas réparer les pièces se trouvant à l'intérieur de l'appareil. Les
réparations doivent être effectuées uniquement par du personnel qualifié.
The Tropos 6310 and 6320 routers are installed in wet, outdoor locations. Make
sure closure caps are installed and all cable connections are securely fastened and
waterproofed.
Surfaces may become hot. Use caution when accessing the Tropos 6310 and 6320
routers.
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 vii
Contents
1 Installing the Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Product Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tropos 6310 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tropos 6320 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Preparing for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Hardware and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Site Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Location Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Site Surveys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Mounting Strategies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Proper Use of Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pole, Tower, and Streetlight Mounting Instructions . . . . . . . . . . . . . . . . . . . . 9
Metal Pole Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wood Pole Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Wood Brace Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Tower Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Streetlight Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Connecting Data Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Grounding the Router. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Grounding the Data Protection Device . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Safety and Servicing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Servicing the Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2 Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3 Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4 Antenna Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5 Installation Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 viii
6 Wind Loading Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 ix
List of Figures
Tropos 6310/ 6320 Router Exploded View . . . . . . . . . . . . . . . . . . . . . . . 3
Example Mounting Location - Antennas Facing Upward . . . . . . . . . . . . 7
Proper Use of the Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Metal Pole Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Placing the Router on the Mounting Assembly . . . . . . . . . . . . . . . . . . . 12
Wood Pole Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Wood Brace Mounting Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Tower Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Streetlight Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Routing the Data/Power Cable to the Router . . . . . . . . . . . . . . . . . . . . 19
Data Port Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Grounding Arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Grounding the Indoor Network Protection Unit . . . . . . . . . . . . . . . . . . . 22
6310/ 6320 Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.4 GHz Antenna Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5 GHz Antenna Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 x
List of Tables
Tropos 6310 Router Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tropos 6320 Router Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Power Options / Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Certifications, Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Installation Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 1
1Installing the Router
This guide explains how to install the Tropos® 6310 and 6320 MetroMesh™ routers safely and
is intended for trained technical professionals. This chapter covers the following topics:
“Product Summary” on page 2
“Preparing for Installation” on page 3
“Mounting Strategies” on page 6
“Proper Use of Clamps” on page 8
“Pole, Tower, and Streetlight Mounting Instructions” on page 9
“Connecting Data Cables” on page 18
“Grounding the Router” on page 21
“Safety and Servicing Information” on page 23
Product Summary
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 2
Product Summary
This document contains installation instructions for the following products:
Tropos 6310 Router
Tropos 6320 Router
Tropos 6310 Router
The Tropos 6310 router has the following characteristics:
802.11b/g/n band, 2400-2483 MHz
Support for 802.11b/g/n clients
PoE power input 20-60 Vdc; 100-277 VAC with external accessory
LAN and Management 10/100BaseT Ethernet ports, auto-sensing
Table 1 lists the Tropos 6310 router models.
Tropos 6320 Router
The Tropos 6320 router has the following characteristics:
802.11a/b/g/n dual band, 2400-2500 MHz/5470-5825 MHz
Support for 802.11a/b/g/n clients
PoE power input 20-60 Vdc; 100-277 VAC with external accessory
LAN and Management 10/100BaseT Ethernet ports, auto-sensing
Table 1 lists the Tropos 6320 router models.
Table 1 Tropos 6310 Router Models
Model Description
63103030 6310: 2.4 GHz, PoE power (FCC)
63102530 6310: 2.4 GHz, PoE power (ETSI)
Table 2 Tropos 6320 Router Models
Model Description
63203030 6320: 2.4 and 5.8 GHz, PoE power (FCC)
63202530 6320: 2.4 and 5.4 GHz, PoE power (ETSI)
Preparing for Installation
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 3
Preparing for Installation
The Tropos 6310 and 6320 routers must be installed by a trained professional, value added
reseller, or systems integrator who is familiar with RF planning issues and regulatory limits
defined by the governing body of the country in which the unit will be installed. This section
explains how to prepare the installation site.
An exploded view of the router assembly is shown in Figure 1.
Note
Operating the unit with non-qualified antennas is a violation of U.S. FCC Rules Part 15.203(c), Code of
Federal Regulations, Title 47.
Figure 1 Tropos 6310/ 6320 Router Exploded View
Trpo_001
Clamp
Pole
bracket
Ground
symbol
LAN port
PoE power input
MGT
port
802.11b/g/n Rx
802.11 a/n Tx/Rx
802.11b/g/n Rx
802.11b/g/n Tx/Rx
IR Receiver
LED
Mounting
bracket
Connector
access cover
Ground connection
Preparing for Installation
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 4
Installation Hardware and Tools
The following installation accessories are included in the shipping package:
One pole bracket
One 4-inch diameter clamp
One 6-inch diameter clamp
Five 5/16-inch #10-32 stainless steel hex head machine screws
You must supply the following tools:
Level
5/16-inch nut driver
1/4-inch flat blade screwdriver
Tower mounting only: stainless or galvanized steel channel stock and 1/2-inch or
5/8-inch nuts, bolts, and washers to connect to the tower arm.
Wood pole mounting only: one 1/4-inch diameter, 3 1/2-inch long lag bolt
Site Planning
To ensure safe and durable wiring, router installation must follow appropriate electrical and
building codes. Follow the National Electrical Code (NEC) requirements, unless local codes in
your area take precedence over the NEC code.
The following distance limits apply to installations that have 10/100 Base-T Category 5 network
cables attached to the routers:
300 feet maximum between devices for 100BaseT operation
500 feet maximum for 10BaseT operation.
The Ethernet duplex and speed setting is configurable.
Note
National Electrical Codes (NEC) Article 800 requires the use of Agency Listed (UL/CSA/TUV) Building
Entrance Protector for all power and data communications cables entering a building. The NEC
intends by Article 800 to protect the building and occupants from fires caused by transient voltage and
current surges.
Note
Ethernet data cable installations having lengths greater than 140 feet in the outdoor environment must
use a UL497 approved (UL/CSA/TUV Listed) primary protection device at the building entrance.
Ethernet data cable installations having lengths less than 140 feet in the outdoor environment may use
a UL497A (UL/CSA/TUV Listed) secondary protection device at the building entrance. Tropos Data
Protection Device and Network Protection Units are UL497A secondary protection devices.
Preparing for Installation
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 5
Location Guidelines
Tropos routers are radio devices and therefore susceptible to interference that can reduce
throughput and range. Follow these guidelines to ensure the best performance:
Install the unit in an area where trees, buildings, and large steel structures do not obstruct
radio signals to and from the antenna. Direct line-of-sight operation is best.
Install the unit away from microwave ovens or other devices operating in the 2.4 GHz,
4.9 GHZ, or 5.8 GHz frequency range.
Install the unit away from other possible sources of 802.11a/b/g/n interference, such as
cordless phones, home spy cameras, frequency hopping (FHSS) and DSSS LAN
transceivers (non-802.11), electronic news gathering video links, radars, amateur radios,
land mobile radio services, local government sites (such as law enforcement), fixed
microwave services, local TV transmission and private fixed point transmitters.
Site Surveys
Due to variations in component configuration, placement, and physical environment, each
installation is unique. Before installing routers, perform a site survey to determine the optimum
placement of units for maximum range, coverage, and network performance. Consider the
following factors when performing a site survey:
Data rates—Sensitivity and range are inversely proportional to data bit rates. The maximum
radio range is achieved at the lowest workable data rate. A decrease in receiver threshold
sensitivity occurs as radio data rate increases.
Antenna orientation—Proper antenna orientation is a critical factor in maximizing radio
range. As a general rule, range increases in proportion to gain and antenna height measured
from the ground.
Physical environment—Clear or open areas provide better radio range than closed or filled
areas. The less cluttered the operating environment, the greater the range.
Obstructions—A physical obstruction, such as a building or tree, can block or hinder
communication. Avoid locating antennas in a location where there is an obstruction between
sending and receiving devices.
Building materials—Radio penetration is influenced by the building material used in
construction. For example, drywall construction permits greater range than concrete blocks.
Mounting Strategies
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 6
Power Source
The Tropos 6310 and 6320 routers are powered by power over Ethernet (PoE) input:
PoE (20-60Vdc)
100-277 VAC with external accessory
Caution
Tropos 6310 and 6320 routers use proprietary PoE. The routers are not 802.3af
compliant.
Safety
Installing the routers can pose a serious hazard. Be sure to take precautions to avoid the
following:
Exposure to high voltage lines during installation
Falls when working at heights or with ladders
Injuries from dropping tools and equipment
Contact with AC wiring
Mounting Strategies
When choosing mounting locations, consider the available mounting structures and antenna
clearance. The router should always be mounted with the top of the unit horizontal and level and
with the antennas facing upward.
It is usually best to attach ground and data cables to the router prior to mounting. Before
mounting the router, review the wiring instructions in “Grounding the Router” on page 21 and
“Connecting Data Cables” on page 18 to determine the best strategy for the selected location.
Note
To eliminate potential interference from the mounting structure, the router should be
mounted with at least 4 feet of clearance around the antennas.
Mounting Strategies
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 7
Acceptable options for mounting on a streetlight are shown in Figure 2. In each case the router is
mounted to assure clearance for the antennas above the height of the streetlight.
Figure 2 Example Mounting Location - Antennas Facing Upward
trpo_002
Antennas clear of obstruction
Antennas clear
of obstruction
Proper Use of Clamps
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 8
Proper Use of Clamps
The mounting assembly contains a clamp to secure the router to the mounting structure. Figure 3
illustrates the proper use of the clamp. The clamp must be routed through a slot in the pole
bracket as shown in the figure, and then attached to the pole and tightened.
The pole bracket should be leveled before it is secured to the pole.
Figure 3 Proper Use of the Clamp
trpo_003
Clamp
Pole
bracket
Mounting
bracket
Band goes
behind
inner tabs
Pole, Tower, and Streetlight Mounting Instructions
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 9
Pole, Tower, and Streetlight Mounting Instructions
This section explains how to mount the router on a pole, tower, or streetlight. It is best to mount
the router to aluminum or galvanized steel structures. The mounting brackets are designed to
pierce any oxidation layers that are on the outside of the pole, thereby assuring good quality
connection to the grounded structure.
Due to potential antenna obstruction issues, the router is not designed to be directly mounted on
a building wall. If it is necessary to mount the router on a wall, follow the instructions for
mounting on a wooden pole (“Wood Pole Mounting” on page 13), and attempt to mount the
router with maximum possible clearance around the antennas.
Note
The router should always be mounted with the top of the router horizontal and level and with the
antennas facing upward.
Note
It is best to attach ground and data cables to the router before sliding the router into the mounting
bracket, as explained in this section. Before mounting the router, review the wiring instructions in
“Grounding the Router” on page 21 and “Connecting Data Cables” on page 18 to determine the best
strategy for the selected location.
Note
Mounting to wood, concrete, or painted poles may require primary grounding for the unit. Check the
national electrical codes in your area for specific rules.
Pole, Tower, and Streetlight Mounting Instructions
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 10
Metal Pole Mounting
Figure 4 illustrates proper mounting for an outdoor metal pole.
Note
Antennas must be clear of obstruction.
Figure 4 Metal Pole Mounting
Clamp
Pole
bracket
Wireless router
Pole, Tower, and Streetlight Mounting Instructions
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 11
Mount the router on a metal pole
1. Select a mounting location. You can attach the router to any pipe or pole with diameter
between 1 inch and 10 inches.
2. Slip the flat portion of the clamp under the inner slot of the pole bracket.
3. Use the clamp to attach the pole bracket to the pole, making sure that it is level. Depending
upon the diameter of the pole, you may need to use a single small clamp, single large clamp,
or pair of large clamps joined together to reach around the pole.
4. Attach the mounting bracket of the router to the pole bracket with two 5/16-inch machine
screws (refer to Figure 4 for the correct orientation):
Insert one screw through the hole at the top of the mounting bracket to the hole at the top
of the pole bracket.
Insert the other screw through the curved slot track in the mounting bracket to the hole in
the middle of the pole bracket just above the clamp slot.
5. Level the mounting bracket by rotating the unit along the curved slot tracks. Tighten the
screws.
6. Place the upright router onto the top of the mounting bracket, as shown in Figure 5. Secure
the mounting bracket to the router by attaching two 5/16-inch machine screws through the
holes in the mounting bracket tabs to corresponding holes on the bottom of the router.
Pole, Tower, and Streetlight Mounting Instructions
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 13
Wood Pole Mounting
Figure 6 illustrates proper mounting for an outdoor wood pole.
Note
Antennas must be clear of obstruction.
Figure 6 Wood Pole Mounting
trpo_005
Pole
bracket
Wireless Router
Pole, Tower, and Streetlight Mounting Instructions
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 14
Mount the router on a wood pole
1. Select a mounting location. You can attach the router to any outdoor wood pole of diameter
at least 1 inch.
2. Attach the pole bracket to the pole by threading a 1/4-inch bolt through the hole in the clamp
slot to the pole. The bolt should be at least 3 1/2 inches in length. Make sure that the bracket
is level.
3. Attach the mounting bracket of the router to the pole bracket with two 5/16-inch machine
screws (refer to Figure 4 for the correct orientation):
Insert one screw through the hole at the top of the mounting bracket to the hole at the top
of the pole bracket.
Insert the other screw through the curved slot track in the mounting bracket to the hole in
the middle of the pole bracket just above the clamp slot.
4. Level the mounting bracket by rotating the unit along the curved slot tracks. Tighten the
screws.
5. Place the upright router onto the top of the mounting bracket, as shown in Figure 5 on page
12. Secure the mounting bracket to the router by attaching two 5/16-inch machine screws
through the holes in the mounting bracket tabs to corresponding holes on the bottom of the
router.
To continue installing the router, see “Connecting Data Cables” on page 18.
Pole, Tower, and Streetlight Mounting Instructions
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 15
Wood Brace Mounting
You can mount the pole bracket directly on a wood brace without using clamps, as shown in
Figure 7.
Figure 7 Wood Brace Mounting Option
Mount the router on a wood pole
1. Select a mounting location. You can attach the router to any wood brace.
2. Attach the pole bracket to the wood brace with two 1/4-inch lag bolts that are at least 3 1/2
inches in length, making sure that the wood brace is level.
3. Attach the mounting bracket of the router to the pole bracket with two 5/16-inch machine
screws (refer to Figure 4 for the correct orientation):
Insert one screw through the hole at the top of the mounting bracket to the hole at the top
of the pole bracket.
Insert the other screw through the curved slot track in the mounting bracket to the hole in
the middle of the pole bracket just above the clamp slot.
4. Level the mounting bracket by rotating the unit along the curved slot tracks. Tighten the
screws.
trpo_006
Wood brace
1/4" lag bolt
3-1/2" minimum
Pole, Tower, and Streetlight Mounting Instructions
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 16
5. Place the upright router onto the top of the mounting bracket, as shown in Figure 5 on page
12. Secure the mounting bracket to the router by attaching two 5/16-inch machine screws
through the holes in the mounting bracket tabs to corresponding holes on the bottom of the
router.
To continue installing the router, see “Connecting Data Cables” on page 18.
Tower Mounting
You can mount the router on an outdoor tower.
Note
At the antenna level, the router must be free from metal obstruction within a 4-foot radius (Figure 8).
Figure 8 Tower Mounting
Mount the Tropos router on a tower
1. Remove the pole bracket from the mounting bracket, if they are attached.
2. Make a tower bracket by attaching the mounting bracket directly to any stainless steel or
galvanized steel channel stock.
3. Attach the mounting bracket to the tower arm so that the top of the shield is horizontal and
level.
4. Tighten the mounting bolts.
5. Place the upright router onto the top of the mounting bracket, as shown in Figure 5 on page
12. Secure the mounting bracket to the router by attaching two 5/16-inch machine screws
through the holes in the mounting bracket tabs to corresponding holes on the bottom of the
router.
To continue installing the router, see “Connecting Data Cables” on page 18.
trp0 007
4'
Brackets not included
Channel stock
Pole, Tower, and Streetlight Mounting Instructions
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 17
Streetlight Mounting
You can mount the router on the horizontal or angled arm of a streetlight. Figure 9 shows a
typical streetlight mounting installation.
Figure 9 Streetlight Mounting
Mount the router on a streetlight
1. Select a mounting location. You can attach the router to any streetlight arm with diameter 1”
to 10”.
2. Slip the flat portion of the clamp under the inner slot of the pole bracket.
3. Use the clamp to attach the pole bracket to the arm, making sure that it is level. Depending
upon the diameter of the arm, you may need to use a single small clamp, single large clamp,
or pair of large clamps joined together.
trpo_00
Pole
bracket
Router
Connecting Data Cables
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 18
4. Attach the mounting bracket of the router to the pole bracket with two 5/16-inch machine
screws (refer to Figure 4 for the correct orientation):
Insert one screw through the hole at the top of the mounting bracket to the hole at the top
of the pole bracket.
Insert the other screw through the curved slot track in the mounting bracket to the hole in
the middle of the pole bracket just above the clamp slot.
5. Level the mounting bracket by rotating the unit along the curved slot tracks. Tighten the
screws.
6. Place the upright router onto the top of the mounting bracket, as shown in Figure 5 on page
12. Secure the mounting bracket to the router by attaching two 5/16-inch machine screws
through the holes in the mounting bracket tabs to corresponding holes on the bottom of the
router.
To continue installing the router, see the next section, “Connecting Data Cables.”
Connecting Data Cables
The router is equipped with two Ethernet ports that support RJ45 connectors. To provide power
to the router as well as wired network connectivity, you must connect an Ethernet cable to the
LAN port. Cable connection to the MGT port is used for router configuration.
This section describes how to connect the Ethernet cables.
Note
The router is shipped pre-configured. For post-installation changes in configuration, you can
communicate with the router by way of its wireless connection. For more information, see the Tropos
Networks Configuration Guide.
Note
Only use shielded Cat5 cable rated for outdoor use. For protection against risk of fire, electrical hazard
and to ensure the reliable operation of this equipment, the shields of the Cat5 cable must be properly
terminated and bonded to the unit and to the protective earth (PE) at the building entrance.
Note
National Electrical Codes (NEC) Article 800 requires the use of Agency Listed (UL/CSA) Building
Entrance Protector for all power and communications cables entering a building. The NEC intends by
Article 800 to protect the building and occupants from fires caused by transient voltage and current
surges.
Warning
DC voltage may be present on RJ-45 pins 4,5 (+) and 7,8 (-)
Connecting Data Cables
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 19
Attention
Une tension continue peut être présente sur les broches RJ-45 4, 5 (+) et 7, 8 (-).
Note
This is not a mid-span powered device. Never attempt to daisy-chain Power Over Ethernet devices.
Connecting the Ethernet cable
1. Have the Ethernet data cable, nut, rubber boots, and cable gland available.
2. Remove the cable gland from the bottom of the router. For power and wired network
connectivity, use the LAN port, which is farther from the edge of the router than the MGT
port (see Figure 11).
3. Press the tab on the RJ45 connector down as you push the cable through the nut. Make sure
that the orientation is consistent with Figure 10.
4. Separate the rubber boot as needed and slide the connector through the boot. Use the boot
with the smaller diameter opening, unless the cable is too wide to permit the boot to close
completely.
5. Slide the cable through the cable gland, as shown in Figure 10.
Figure 10 Routing the Data/Power Cable to the Router
trpo_014
Nut
Cable gland
Rubber boot
Connecting Data Cables
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 20
6. Plug the cable into the appropriate port on the router. For power and wired network
connectivity, plug the cable into the LAN port, which is farther from the edge of the router
than the MGT port (see Figure 11).
7. Screw the cable gland onto the bottom of the router, and then slide the nut over the rubber
boot and screw both tightly to the cable gland. Tighten the nut to ensure a positive water
seal. Figure 11 shows how the cable assembly is attached to the bottom of the router.
Figure 11 Data Port Connection
trpo_012
Shielded outdoor
cat5 cable
drip loop
Shield termination
Cable gland
(watertight)
Tighten four screws to
fasten cable gland
Access area
LAN port
(includes power)
MGT port
Grounding the Router
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 21
Grounding the Router
Caution
You must install an external grounding wire if the router is installed on a non-metal pole
or if the metal installation structure is not properly grounded. You must also ground the
outdoor data protection device to a bonded pipe or ground rod. Make sure that
grounding is complete before you connect power to the router.
The grounding arrangement for the router is shown in Figure 12.
Figure 12 Grounding Arrangement
Ground the router
1. Insert the grounding screw into the grounding screw hole on the bottom of the router.
2. Connect a length of #10 AWG bare copper wire to the grounding screw and tighten.
3. Connect the other end of the grounding wire to a grounding strap that is attached to a
grounded surface or other earth ground, such as a grounding rod.
trp0_009
10 AWG wire
to ground
Grounding strap
on pipe or grounding rod
Grounding
screw
Grounding the Router
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 22
Grounding the Data Protection Device
The grounding arrangement for an indoor data protection device is shown in Figure 13.
Ground an indoor data protection device
1. Place the protection device as close to the building entrance as possible.
2. Connect a length of #10 AWG bare copper wire to the ground post on the data protection
device.
3. Connect the other end of the grounding wire to the ground connection of an electrical outlet
or a grounded water pipe.
Figure 13 Grounding the Indoor Network Protection Unit
trp_140
10 AWG wire
to ground
Grounding wire
to elecrtical outlet ground
or water pipe
Indoor network
protection unit
To network
Data cable enters
building wall
through conduit
Shielded RJ45 ports
Safety and Servicing Information
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 23
Safety and Servicing Information
The Federal Communications Commission (FCC) with its action in ET Docket 96-8 has adopted
a safety standard for human exposure to RF electromagnetic energy emitted by FCC certified
equipment. The Tropos 6310 and 6320 routers meet the uncontrolled environmental limits found
in OET-65 and ANSI C95.1, 1991. Proper operation of this device according to the instructions
found in this manual and the hardware and software guides on the router results in user exposure
that is substantially below the FCC recommended limits.
Safety Guidelines
Follow these guidelines to ensure safe operation of the router:
Do not touch or move the antennas while the unit is transmitting or receiving.
Do not hold any component containing a radio such that the antenna is very close to or
touching any exposed parts of the body, especially the face or eyes, while transmitting.
Do not operate the radio or attempt to transmit data unless the antenna is connected;
otherwise, the radio may be damaged.
Use in specific environments:
Do not operate a portable transmitter near unshielded blasting caps or in an explosive
environment unless it is a type especially qualified for such use.
The use of wireless devices in hazardous locations is limited to the constraints posed by
the safety directors of such environments.
The use of wireless devices on airplanes is governed by the Federal Aviation
Administration (FAA).
The use of wireless devices in hospitals is restricted to the limits set forth by each
hospital.
Servicing the Router
The router has no user serviceable parts inside. For any service-related issues, contact Tropos
Customer Support (support@tropos.com).
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 25
3Product Specifications
The tables in this chapter contain specifications for the Tropos 6310 and 6320 routers:
“Physical Specifications” on page 25
“Interfaces” on page 27
“Power Options / Consumption” on page 30
“Certifications, Other” on page 30
Table 3 Physical Specifications
Specification Value
Physical Dimensions
Inches Height: 2.5" (6.4cm) without antennas
Height: 14.25" (36.2cm) with antennas
Width: 8.75" (22.2cm)
Depth: 7.25" (18.4cm)
Weight
lbs - maximum
Kg - maximum
4 lbs (1.8 kg)
5 lbs (2.3 kg) with mounting brackets
Mounting
Mounting Pole Diameter 1” to 10”
Temperature
Operating Range Min: -40o C
Max: 55o C
Storage Range Min: -40o C
Max: 85o C
Weather
Weather Rating IP67 weathertight
Wind Survivability > 165 mph
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 26
Wind Loading (165 mph) < 210 newtons
Projected Area 0.7 sq. ft. (100 sq. in.)
Corrosion Resistance ASTM B117 Salt Fog rust resistance compliant
Color
Color Unpainted metal/White Radome
Shock and Vibration
Operational: ETSI 300-19-2-4
Specification T41.E,
class 4M3
Transportation: ISTA 2A
Reliability
Reliability (MTBF) 505,787 hours demonstrated
Field failure rate 1.73%
Status Lamp
Indicators Green/Red/Blue
Table 3 Physical Specifications (continued)
Specification Value
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 27
Table 4 Interfaces
Specification Value
LAN Interface
IEEE 802.3 10/100BaseT •Auto sensing
•Maximum Distance (ft):
550 (10BaseT Duplex Setting)
300 (100BaseT Duplex Setting)
•RJ45 connector
MGT Interface
IEEE 802.3 10/100Base T •Auto sensing
•Maximum Distance (ft):
550 (10BaseT Duplex Setting)
300 (100BaseT Duplex Setting)
•RJ45 connector
802.11b/g/n Wireless Interface
Standard IEEE 802.11b/g/n Wi-Fi
Frequency Range •2400 to 2483 MHz ISM Band (CH 1-11) FCC Part 15
Models: 63103030, 63203030
•2400 to 2500 MHz (CH 1-13) ETSI/EU
Models: 63102530, 63202530
Modulation 802.11g/n - OFDM (64-QAM, 16-QAM, QPSK, BPSK)
802.11b - DSSS (DBPSK, DQPSK, CCK)
Rx Sensitivity
Tx Power ETSI/EU 5dBm-20dBm (EIRP) set in 1dB units
FCC/IC 19dBm-34dBm (EIRP) set in 1dB units
-97dBm @ 1 Mbps -95dBm @ 18 Mbps
-94dBm @ 5.5 Mbps -92dBm @ 24 Mbps
-92dBm @ 11 Mbps -89dBm @ 36 Mbps
-96dBm @ 6 Mbps -85dBm @ 48 Mbps
-96dBm @ 12 Mbps -84dBm @ 54 Mbps
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 28
Rx Saturation
Maximum Power at Antenna
Port
-5dBm (1 Mbps)
-5dBm (2 Mbps)
-5dBm (5.5 Mbps)
-5dBm (11 Mbps)
-5dBm (6 Mbps)
-5dBm (9 Mbps)
-5dBm (12 Mbps)
-10dBm (18 Mbps)
-30dBm (24 Mbps)
-35dBm (36 Mbps)
-35dBm (48 Mbps)
-35dBm (54 Mbps)
Antennas Multi-antenna system: 1-TX x 3-RX
6dBi omnidirectional integrated antennas
Support for 802.11n MRC
802.11a/n Wireless Interface
Standard IEEE 802.11a/n Wi-Fi
Frequency Range 5.725 - 5.850 GHz (FCC/IC)
5.470 - 5.725 GHz (ETSI/EU)
Modulation OFDM (64-QAM, 16-QAM)
Rx Sensitivity
Tx Power ETSI/EU 15dBm-30dBm (EIRP) set in 1dB units
FCC/IC 18dBm-33dBm (EIRP) set in 1dB units
Table 4 Interfaces (continued)
Specification Value
-92dBm @ 6 Mbps -84dBm @ 24 Mbps
-91dBm @ 9 Mbps -81dBm @ 36 Mbps
-90dBm @ 12 Mbps -77dBm @ 48 Mbps
-87dBm @ 18 Mbps -75dBm @ 54 Mbps
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 29
Rx Saturation
Maximum Power at Antenna
Port
-30dBm (6 Mbps)
-30dBm (9 Mbps)
-30dBm (12 Mbps)
-30dBm (18 Mbps)
-30dBm (24 Mbps)
-35dBm (36 Mbps)
-35dBm (48 Mbps)
-35dBm (54 Mbps)
Antennas Multi-antenna system: 1-TX x 1-RX
8dBi omnidirectional integrated antennas
Support for 802.11n
Table 4 Interfaces (continued)
Specification Value
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 30
Table 5 Power Options / Consumption
Specification Value
Antenna Protection <= 0.5μJ for 3kA @ 8/20μS Waveform
EN61000-4-2 Level 4 ESD Immunity
EN61000-4-5 Level 4 Surge Immunity
Data Port Protection EN61000-4-2 Level 4 ESD Immunity
EN61000-4-5 Level 4 Surge Immunity
Power
Power Input Power input: PoE (20-60Vdc)
100-277 VAC with external accessory
Power Consumption 10 W typical
Table 6 Certifications, Other
Regulatory Domain Specification
U.S. CFR 47 FCC Part 90
CFR 47 FCC Part 15.C; Class B
UL579/IEC 60529 IP67 Rated for Outdoor Use
ISTA 2A
Europe EN60950 cTUVus Listed I.T.E.
IEEE/ANSI C62.41 Category C AC Surge Immunity
EN61000-4-5 Level 4 AC Surge Immunity
EN61000-4-2 Level 4 ESD Immunity
EN61000-4-4 Level 4 EFT Burst Immunity
EN61000-4-3 EMC Field Immunity
ETSI EN 301 489-17
ETSI EN 300 328
EN 60950-1, IEC 60950-1
CISPR 22 Class B
CE
Canada Industry Canada RSS210
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 32
2.4 GHz Antennas
Specifications for the 2.4 GHz antennas:
Integrated omni antenna
Length: 11.5” (29.2 cm)
Average gain azimuth: 5.2dBi
Peak gain: 6.0 dBi
Maximum efficiency: 73%
Antenna Patterns are shown in Figure 15.
Figure 15 2.4 GHz Antenna Patterns
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 33
5 GHz Antenna
Specifications for the 5 GHz antenna:
Integrated omni antenna
Length: 10” (25.4 cm)
Average gain azimuth: 7.0dBi
Peak gain: 8.0 dBi
Maximum efficiency: 68%
Antenna Patterns are shown in Figure 16.
Figure 16 5 GHz Antenna Patterns
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 34
5Installation Accessories
This chapter contains accessory ordering information:
Table 7 Installation Accessories
Description Manufacturer Part Number Distributor Contact Information
Outdoor CAT5 4-Pair Data
Cable
Belden
Belden
7929A
7921A
(recommended)
Anixter
Anixter
www.anixter.com
www.anixter.com
Superior
Essex
BBDG Crossover
Distribution
www.crossoverdistribution.com
Cable, CAT5, 8 Conductor,
Harsh Environment
Madison
Cable
08KFK00013 Tyco www.madisoncable.com
Data Protection Device Polyphaser IX-2H1DC48/W Polyphaser www.polyphaser.com
Hyperlink HGLN-CAT5-1 Hyperlink www.hyperlinktech.com
Data and PoE Protection
Device
Polyphaser POLNX4-60 Talley
Communications,
Inc.
www.talleycom.com
Universal remote control Universal
Remote
MX-500 Amazon www.amazon.com
PoE PSE 90-264VAC
PoE injector
Skynet SNP-POET 48V
SNP-POE9 24V
PowerGate www.powergatellc.com/
EnGenius EBU-101-01 Netgate www.netgate.com
Pole Power ANSI C136.10
PoE
SB Wireless SB-POEAPT-2448 SB Wireless www.sbwireless.com
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 35
6Wind Loading Considerations
The American Association of State Highway and Transportation Officials (AASHTO) standards
manual, “Standard Specifications for Structural Supports for Signs, Luminaires and Traffic
Signals,” governs most structural support issues related to traffic lighting and controls. Many
state and city public works departments site the AASHTO standard as the guide for their
requirements. Local municipalities in coastal states, which experience frequent hurricanes, etc.,
may have exceptions to the AASHTO standard that require higher design limits for wind
velocity or dead load.
Numerous pole and mast arm assemblies are used for traffic controls and traffic lighting. Each
assembly and installation is unique and worthy of an evaluation of the static and dynamic load
bearing capabilities; however, in most cases, the assembly will include a pole with a single 6', 9'
or 12' mast arm holding a single luminaire. Many of these mast arms are typically designed to
hold hundreds of pounds of static load and to carry several square meters of sail area in 80mph
winds. The typical mast arm is capable of supporting a single traffic control (typically weighing
around 160 lbs) and a single traffic sign (typically presenting a few square meters of sail area). A
single luminaire typically weighs about 60 lbs and presents about 3 square feet of sail area.
Note
Each assembly and installation is unique and worthy of an evaluation of the static and
dynamic load bearing capabilities. It is your responsibility to evaluate the load bearing
capabilities of the structure.
The router weighs approximately 5 lbs, including all mounting hardware. The router can be
mounted to the pole portion of the streetlight or to the mast arm portion.
When the router is mounted to the pole or mast arm, most of the unit is hidden by the pole or
mast arm and therefore presents minimal additional sail area to the structure. When the router is
mounted to the pole portion of the structure, the sail area of the router is approximately 1 square
foot. Pole manufacturers have advised Tropos Networks that small communications devices
such as Tropos routers do not present any significant static or dynamic load to these structures.
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 36
Abbreviations
The following acronyms are used in this document.
Table 8 Abbreviations
2P Two-Phase or Split Phase
2W Two-Wire
3W Three-Wire
AASHTO American Association of State Highway and Transportation Officials
AC Alternating Current
ANSI American National Standards Institute
AWG American Wire Gauge
C Celsius
CAT Category
CCK Complementary Code Keying
CE Conformite Europeene
CFR Code of Federal Regulations
CISPR International Special Committee on Radio Interference
CSA Canadian Standard Association
dB Decibels
dBi Decibels Relative to an Isotropic Radiator
dBm Decibels Referred to 1 Milliwatt
DBPSK Differential-Binary Phase-Shift Keying
DC Direct Current
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 37
DGT Directorate General of Telecommunications (Taiwan)
DQPSK Differential-Quadrature Phase-Shift Keying
DSSS Direct-Sequence Spread Spectrum
EFT Electrically Fast Transients
EIRP Effective Isotropic Radiated Power
EMC Electromagnetic Compatibility
EN IEC standard
ESD Electrostatic Discharge
ETSI European Telecommunications Standards Institute
EU European Union
FCC Federal Communications Commission
FHSS Frequency Hopping Spread Spectrum
HFC Hybrid Fiber Coax
Hz Hertz
IEC International Electrotechnical Commission
IEEE Institute of Electrical and Electronics Engineers
IP67 Ingress Protection Standard
ISM Instrumentation, Scientific, and Medical band
ISTA International Safe Transit Association
LAN Local Area Network
Mbps Megabits Per Second
MHz Megahertz
MIL-STD Military Standard
MPHPT Ministry of Public Management, Home Affairs, Posts and Telecommunications (Japan)
MSO Multiple Service Operator
MTBF Mean Time Between Failure
N Neutral
Table 8 Abbreviations (continued)
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 38
NEC National Electrical Codes
NEMA National Electrical Manufacturers Association
OFDM Orthogonal Frequency Division Multiplexing
P Phase
PE Protective Earth
PoE Power over Ethernet
RJ45 Registered Jack 45
RSS Received Signal Strength
Rx Receive
RXD Receive Data
TUV Technical Inspection Association
Tx Transmit
TXD Transmit Data
UL Underwriters Laboratories
UPS Uninterruptible Power Supply
VAC Voltage (Alternating Current)
VCCI Voluntary Control Council for Interference (Japan)
VDC Voltage (Direct Current)
VSWR Voltage Standing Wave Ratio
WWatts
Table 8 Abbreviations (continued)
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320 39
Index
Numerics
2.4 GHz antenna 32
2.4 GHz antennas 32
5 GHz antenna 33
6310 router 2
6320 router 2
A
accessories 34
American Association of State Highway and Transportation
Officials (AASHTO) 35
antennas
2.4 GHz 32
5 GHz 33
patterns 32, 33
type and placement 5
B
building materials 5
C
cable gland 19
cautions vi
certifications 30
clamps 8
clearance for mounting 6
concrete pole mounting 9
connecting a data port 18
D
data cables
attaching before mounting 6
data port
connecting 18
data protection device 22
data rate considerations 5
distance limits 4
diversity 5
F
FCC antenna rules 3
G
grounding
connecting 22
data protection device 22
router 21
I
installation hardware and tools 4
installation, site surveys 5
installing Tropos router 1
interfaces 27
L
LAN port 18
location guidelines 5
M
management port 18
metal pole mounting 10
models 2
mounting
clearance 6
instructions 9
large diameter poles 8
metal pole 10
orientation 6
strategies 6
streetlight 17
streetlight options 7
to wood, concrete, painted poles 9
tower 16
wood brace 15
wood pole 13
O
obstructions 5
order numbers 34
Tropos MetroMesh Routers Installation Guide, Models 6310 and 6320
P
physical environment 5
pole mounting 10
ports 18
power
consumption 24
source 6
specifications 30
preparing for installation 3
product specifications
certifications 30
interfaces 27
physical 25
power 30
R
regulatory notices ii
RJ45 Ethernet ports 18
router
diagram 3
exploded view 3
router models 2
rubber boot 19
S
safety
general considerations 6
information 23
site planning 4
site surveys 5
specifications
certifications 30
interfaces 27
physical 25
power 30
streetlight
mounting instructions 17
mounting options 7
T
tools for installation 4
tower mounting 16
W
warnings, general vi
wind loading 35
wood brace mounting 15