ACSI Elec. Exit Device For Print Series 1500 Electric Lock Catalog Locks
User Manual: ACSI Series 1500 Electric Lock Catalog Literature
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
A C S I 1 - 8 0 0 - 7 5 3 - 5 5 5 8 E L E C T R I C L O C K M O D I F I C AT I O N L I S T I N G L O C K S C H E M AT I C S Note: If you do not find the lock of your choice listed, please consult with our factory engineering staff. We may request that you send a sample for further evaluation. Manufacturer Arrow Baldwin Best Corbin Russwin Dorma Falcon Hager PDQ Sargent Schlage Yale Mortise Locks AM17 BM17 6065 6065LS 35H7J, 45H7J 2055 ML9070 ML561, MA561 3850 MR148 8237 L9050 L9070 L9080* 9453 8808 A C S I Cylindrical Locks H12 Q12 Unit Locks AE - Authorized Egress E L E C T R I C A L S P E C I F I C AT I O N S LM - Latchbolt Monitor RED - Normally Open BLACK - Common YELLOW - Common RED - Closed Loop Secure GRAY - Normally Closed WHITE - Open Loop Secure SM - Security Monitoring BLACK - Common 1 - 8 0 0 - 7 5 3 - 5 5 5 8 1510/1520 BLUE BLUE M1510/1520 C1510/1520 MU1510/1520 12VAC/DC 24VAC/DC 12VAC/DC 24VAC/DC 12VAC/DC 24VAC/DC 612 330 250 150 612 330 ma ma ma ma ma ma L O C K I N T O T H E A C S I A D VA N TA G E L O C K I N T O T H E A C S I A D VA N TA G E AC POWER LEADS GREEN - Closed Loop Secure 3357 UT5257 BROWN - Open Loop Secure WHITE WHITE DC POWER LEADS Note: Red TY-Wrap on leads designates 12 volt T561 3480 10G04 D80 Rhodes (Lever) D53 (Knob) D94 ND80, ND94 5405LN M O D I F I C AT I O N S T O : ARROW *Schlage L9080 must be supplied with extra spring cage to compensate for lever sag of outside trim. BALDWIN BEST E L E C T R I C L O C K C O M PA R I S O N C H A RT ACSI Arrow M1510C-00-1 A17-177 B17-177 M1510C-00-2 M1520C-00-1 A17-178 B17-178 M1520C-00-2 C1510C-00-1 C1520C-00-1 Q12-177 H12-177 Q12-178 H12-178 AE LM* SM* DM* Best EWEL Corbin Russwin 20903 20910 WWEL 20901 20920 EWEU 20905 20930 WWEU 20940 20940 33903 Dorma ML9080EL Falcon Sargent M851 8270 Schlage L9080EL CORBIN/RUSSWIN Yale 8890 FA L C O N HAGER MARKS ML9082EL M811 8272 L9082EL 8894-2 ML9080EU M881 8271 L9080EU 8891 PDQ SARGENT SCHLAGE L9082EU M821 8273 L9082EU 8895-2 10G70 ND80PDEL 5490 10G71 ND80PDEU 5491 RX LX* RX YA L E S E R I E S 33905 RQE LS* M92 M91* M105* RX* 1 5 0 0 E L E C T R I C L O C K C A T A L O G REX LBM* DX* *Available Mortise Only 2720 Clark Avenue • St. Louis, Missouri 63103 • 1-800-753-5558 • 314-652-5588 • FAX: 314-652-2090 • WWW.ACSI-INC.COM 2720 Clark Avenue • St. Louis, Missouri 63103 • 1-800-753-5558 • 314-652-5588 • FAX: 314-652-2090 • WWW.ACSI-INC.COM A C S I 1 - 8 0 0 - 7 5 3 - 5 5 5 8 A C S I SERIES 1500 E L E C T R I C L O C K S HOW TO ORDER (cont.) ACSI supplies high quality UL Listed modifications to a wide range of manufacturer’s locksets. Series 1500 electric locks provide safety and security for stairtower doors or controlled areas where both locking and latching are required. The Series 1500 locks allow remote electric locking or unlocking while conforming to life-safety codes. Features • UL Listed • Fail Safe (Power Lock) Outside trim is locked when power is applied and unlocked when power is removed (storeroom function when energized). Lockset will unlock in event of power failure (passage function). • Fail Secure (Power Unlock) Outside trim is unlocked when power is applied and locked when power is removed. Lockset will lock in event of power failure. • Continuous duty solenoids • 24VDC, 24VAC, 12VDC, or 12VAC, operation • When key cylinders are provided in the locks, the latchbolt may be momentarily retracted with key even though electrically locked. NOTE: Locks that are electrically unlocked may not be locked via the key cylinder. • Wide variety of monitoring options are available • Interface with Life-Safety Systems Typical Installation 115V, INPUT SERIES 1440 POWER SUPPLY SERIES 1300 DOOR CONTROL SERIES 1100 ELECTRIC HINGE WIRES IN CONDUIT (IF FRAMES ARE FILLED) 302-03-03 MORTAR GUARD (IF FRAMES ARE FILLED) Applications Stairtower doors, office doors, classrooms, interlocks, elevator lobby doors, laboratories, computer rooms, cashier stations, hospital equipment rooms, pharmaceutical storage rooms. DM DPS MK-10 2 2 Modification Number 3 Options 4 Locking 5 Lock Part No. 6 Operating Voltage 7 Quick Connect Cable 8 Handing M C MU 1510 1520 1500 AE LM SM 1 2 Full Part Number 24VDC 24VAC/DC 12VDC 12VAC/DC QC LC RH LH RHR LHR 1510 AE 1 1. Lock Type (Select type of lock to be modified) Description Mortise Lock Cylindrical Lock Unit Lock L9070 (Schlage) 24VDC 2. Modification Number (Select type of modification required) Model 1510 1520 Description Fail Safe Control Fail Secure Control RH Description Standard control locks outside (secure side) trim. Locks both sides – Mortise locks only. 5. Lock Part No. Distributors supply ACSI with mortise, cylindrical, or unit locks for modification. Please supply the lock manufacturer’s part number. Example: L9070, 8237, 8808, ND80, 3357, etc. Note: Refer to the last page of this catalog section for a complete listing of locks required by ACSI. 6. Operating Voltage Model 24VDC 12VDC 24VAC/DC 12VAC/DC Note: Mortise locks can be supplied with pneumatic control. Consult factory. 1 - 8 0 0 - 7 5 3 - 5 5 5 8 ACCESSORIES Description Authorized Egress (Mortise or Cylindrical Lock) ACSI Authorized Egress is a SPDT switch which monitors the activation of the INSIDE trim. The AE switch can be used to: • Shunt a door alarm to allow egress • Signal a control console when the trim is activated • Activate a door alarm • Control an electromagnetic lock for egress Latch Bolt Monitor (Mortise Lock)* • Latch bolt monitoring is a SPDT switch which monitors the full extension of the main latch. Security Monitoring (Mortise Lock)* • The ACSI SM option monitors, in series, solenoid status (locked or unlocked) and latch status (deadlatch position). Deadbolt Monitor (Mortise Lock)* • Deadbolt monitoring is a SPDT switch which monitors the extension of the deadbolt. Door Position Sensor (Mortise Lock)* • Door position monitoring is a SPDT magnetic sensor used to confirm door position. Magnetic sensors mounted in the mortise lock react to the proximity of a magnet mounted in the ASA strike. (Strike not included) • Consult Factory for Models Available Authorized Egress Kit • Field installable for Schlage L series mortise lock Note: Leave #3 blank if no options are required. * Not available on cylindrical locks or unit locks. Model 1 1 Lock Type Model M C MU SM 4. Locking HOW TO ORDER Example: M Model AE LM QC DOOR CABLE SERIES 1500 ELECTRIC LOCK 3. Options A C S I 1 - 8 0 0 - 7 5 3 - 5 5 5 8 7. Quick Connect Cable Model QC LC 8. Handing Model RH LH RHR LHR Description Quick Connect Cable • QC 6' quick connect cable. Allows for ease of installation in transfer of power from the lock to the electric hinge. Lynx Connector (ASSA Connector) • LC4 4 pin connector • LC8 8 pin connector • LC12 4 pin and 8 pin connectors Description Right Hand Left Hand Right Hand Reverse Left Hand Reverse Model 1580-1 1580-2 Description AC/DC Converter Voltage Regulator • Regulates source voltages up to 30 volts DC (35 volts AC) to a 24VDC output level. • Works with AC or DC source voltages • Can be used with 24VAC/DC rated cylindrical or mortise locks up to 360MA. • UL Listed E L E C T R I C M O RT I S E L O C K B O D I E S ACSI Stocks Electric Mortise Lock Bodies available in Schlage, Corbin Russwin, Sargent, Yale, Best, Falcon, and Dorma. The locks are available in fail safe and fail secure, 24 volt or 12 volt and a variety of monitoring options. Model M1510 M1510 M1510 M1510 M1510 M1510 M1510 M1520 M1520 M1520 M1520 M1520 M1520 M1520 L9070B 2055B 8237B 8808B 45H75B MA561B ML9070B L9070B 2055B 8237B 8808B 45H75B MA561B ML9070B 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC 24VAC/DC Mortise Lock Body Schlage-Fail Safe Corbin Russwin-Fail Safe Sargent-Fail Safe Yale-Fail Safe Best-Fail Safe Falcon-Fail Safe Dorma-Fail Safe Schlage-Fail Secure Corbin Russwin-Fail Secure Sargent-Fail Secure Yale-Fail Secure Best-Fail Secure Falcon-Fail Secure Dorma-Fail Secure ELECTRIC CYLINDRICAL LOCKS ACSI Stocks Electric Cylindrical locks available in a Schlage, Sargent, Yale and Corbin Russwin. Authorized Egress (Request to Exit) and 12 volt options are available. Model C1510 C1520 ND80B ND80B C1510 C1510 C1510 10G04B 24VAC/DC LL 626 3357B 24VAC/DC NZD 626 5405LNB 24VAC/DC AU 626 24VAC/DC 24VAC/DC Cylindrical Lock Schlage-Fail Safe Schlage-Fail Secure Note: Specify trim style, format and finish. Available in Rhodes, Sparta and Athens trim style. Finishes available in 626, 625 and 613. C1520 C1520 C1520 10G04B 24VAC/DC LL 626 3357B 24VAC/DC NZD 626 5405LNB 24VAC/DC AU 626 Sargent-Fail Safe Corbin Russwin-Fail Safe Yale-Fail Safe Sargent-Fail Secure Corbin Russwin-Fail Secure Yale-Fail Secure
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2011:11:07 17:47:30Z Creator : QuarkXPress(R) 7.5 Modify Date : 2011:12:12 12:29:31-06:00 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : QuarkXPress(R) 7.5 Metadata Date : 2011:12:12 12:29:31-06:00 Producer : QuarkXPress(R) 7.5 Format : application/pdf Title : Elec. Exit Device for Print Document ID : uuid:c7062cda-c659-4b81-a2f3-9774b1e2e865 Instance ID : uuid:56759ed0-044a-4559-8639-c131126dba47 Page Count : 2EXIF Metadata provided by EXIF.tools