ACSI Elec. Exit Device For Print Series 1500 Electric Lock Catalog Locks

User Manual: ACSI Series 1500 Electric Lock Catalog Literature

Open the PDF directly: View PDF PDF.
Page Count: 2

2720 Clark Avenue • St. Louis, Missouri 63103 • 1-800-753-5558 • 314-652-5588 • FAX: 314-652-2090 • WWW.ACSI-INC.COM
LOCK INTO THE ACSI ADVANTAGE
LOCK INTO THE ACSI ADVANTAGE
S E R I E S 1 5 0 0 E L E C T R I C L O C K C A T A L O G
M O D I F I C AT I O N S T O :
A R R O W
B A L D W I N
B E S T
C O R B I N / R U S S W I N
FA L C O N
H A G E R
M A R K S
P D Q
S A R G E N T
S C H L A G E
YA L E
ACSI 1-800-753-5558
AE - Authorized Egress LM - Latchbolt Monitor
Note: Red TY-Wrap on leads designates 12 volt
LOCK SCHEMATICS ELECTRICAL S P E C IFICATIONS
RED - Normally Open
YELLOW - Common
GRAY - Normally Closed
BLACK - Common
RED - Closed Loop Secure
WHITE - Open Loop Secure
SM - Security Monitoring 1510/1520
BLACK - Common
GREEN - Closed Loop Secure
BROWN - Open Loop Secure
BLUE AC POWER
BLUE LEADS
WHITE DC POWER
WHITE LEADS
M1510/1520 12VAC/DC 612 ma
24VAC/DC 330 ma
C1510/1520 12VAC/DC 250 ma
24VAC/DC 150 ma
MU1510/1520 12VAC/DC 612 ma
24VAC/DC 330 ma
*Schlage L9080 must be supplied with extra spring cage to compensate for lever sag of outside trim.
ELECTRIC LOCK MODIFICATI O N L I STING
ACSI Arrow Best Corbin Russwin Dorma Falcon Sargent Schlage Yale
M1510C-00-1 A17-177 EWEL 20903 ML9080EL M851 8270 L9080EL 8890
B17-177 20910
M1510C-00-2 WWEL 20901 ML9082EL M811 8272 L9082EL 8894-2
20920
M1520C-00-1 A17-178 EWEU 20905 ML9080EU M881 8271 L9080EU 8891
B17-178 20930
M1520C-00-2 WWEU 20940 L9082EU M821 8273 L9082EU 8895-2
20940
C1510C-00-1 Q12-177 33903 10G70 ND80PDEL 5490
H12-177
C1520C-00-1 Q12-178 33905 10G71 ND80PDEU 5491
H12-178
AE RQE M92 RX* RX RX REX
LM* LS* M91* LX* LBM*
SM* M105*
DM* DX*
ELECTRIC LOCK COMPARISO N C H A RT
*Available Mortise Only
ACSI 1-800-753-5558
2720 Clark Avenue • St. Louis, Missouri 63103 • 1-800-753-5558 • 314-652-5588 • FAX: 314-652-2090 • WWW.ACSI-INC.COM
Note: If you do not find the lock of your choice listed, please consult with our factory engineering staff. We
may request that you send a sample for further evaluation.
Manufacturer Mortise Locks Cylindrical Locks Unit Locks
Arrow AM17 H12
BM17 Q12
Baldwin 6065
6065LS
Best 35H7J, 45H7J
Corbin Russwin 2055 3357 UT5257
Dorma ML9070
Falcon ML561, MA561 T561
Hager 3850 3480
PDQ MR148
Sargent 8237 10G04
Schlage L9050 D80 Rhodes (Lever)
L9070 D53 (Knob)
L9080* D94
9453 ND80, ND94
Yale 8808 5405LN
4. Locking
Model Description
1Standard control locks outside
(secure side) trim.
2Locks both sides – Mortise locks only.
HOW TO ORDER
1. Lock Type (Select type of lock to be modified)
Model Description
MMortise Lock
CCylindrical Lock
MU Unit Lock
ACSI supplies high quality UL Listed modifications to a wide range of manufacturer’s locksets. Series 1500
electric locks provide safety and security for stairtower doors or controlled areas where both locking and
latching are required. The Series 1500 locks allow remote electric locking or unlocking while conforming to
life-safety codes.
SERIES 1500 ELECTRIC LOCKS
Features
UL Listed
Fail Safe (Power Lock)
Outside trim is locked when power is applied and
unlocked when power is removed (storeroom
function when energized). Lockset will unlock in
event of power failure (passage function).
Fail Secure (Power Unlock)
Outside trim is unlocked when power is applied
and locked when power is removed. Lockset will
lock in event of power failure.
Continuous duty solenoids
24VDC, 24VAC, 12VDC, or 12VAC, operation
When key cylinders are provided in the locks, the
latchbolt may be momentarily retracted with key
even though electrically locked. NOTE: Locks
that are electrically unlocked may not be locked
via the key cylinder.
Wide variety of monitoring options are available
Interface with Life-Safety Systems
Applications
Stairtower doors, office doors, classrooms, inter-
locks, elevator lobby doors, laboratories, computer
rooms, cashier stations, hospital equipment rooms,
pharmaceutical storage rooms.
Typical Installation
ACSI 1-800-753-5558
SERIES 1300
DOOR CONTROL
115V, INPUT
QC
DOOR CABLE
SERIES 1100
ELECTRIC
HINGE
WIRES IN
CONDUIT
(IF FRAMES
ARE FILLED)
302-03-03
MORTAR
GUARD
(IF FRAMES
ARE FILLED)
SERIES
1440
POWER
SUPPLY
SERIES
1500
ELECTRIC
LOCK
12 3456 78
Lock Modification Options Locking Lock Operating Quick Handing
Type Number Part No. Voltage Connect
Cable
M 1510 AE 1 Full 24VDC QC RH
C 1520 LM 2 Part 24VAC/DC LC LH
MU 1500 SM Number 12VDC RHR
12VAC/DC LHR
Example:
M 1510 AE 1 L9070 (Schlage) 24VDC RH
7. Quick Connect Cable
Model Description
QC Quick Connect Cable
QC 6' quick connect cable. Allows
for ease of installation in transfer
of power from the lock to the
electric hinge.
LC Lynx Connector (ASSA Connector)
• LC4 4 pin connector
• LC8 8 pin connector
• LC12 4 pin and 8 pin connectors
6. Operating Voltage
Model
24VDC 24VAC/DC
12VDC 12VAC/DC
Note: Mortise locks can be supplied with pneumatic
control. Consult factory.
3. Options
Model Description
AE Authorized Egress (Mortise or Cylindrical Lock)
ACSI Authorized Egress is a SPDT switch which monitors the activation of the INSIDE trim.
The AE switch can be used to:
• Shunt a door alarm to allow egress
• Signal a control console when the trim is activated
• Activate a door alarm
• Control an electromagnetic lock for egress
LM Latch Bolt Monitor (Mortise Lock)*
• Latch bolt monitoring is a SPDT switch which monitors the full extension of the main latch.
SM Security Monitoring (Mortise Lock)*
• The ACSI SM option monitors, in series, solenoid status (locked or unlocked) and latch status
(deadlatch position).
DM Deadbolt Monitor (Mortise Lock)*
• Deadbolt monitoring is a SPDT switch which monitors the extension of the deadbolt.
DPS Door Position Sensor (Mortise Lock)*
• Door position monitoring is a SPDT magnetic sensor used to confirm door position. Magnetic
sensors mounted in the mortise lock react to the proximity of a magnet mounted in the ASA
strike. (Strike not included)
• Consult Factory for Models Available
MK-10 Authorized Egress Kit
• Field installable for Schlage L series mortise lock
Note: Leave #3 blank if no options are required.
*Not available on cylindrical locks or unit locks.
5. Lock Part No.
Distributors supply ACSI with mortise, cylindrical, or
unit locks for modification. Please supply the lock
manufacturer’s part number.
Example: L9070, 8237, 8808, ND80, 3357, etc.
Note: Refer to the last page of this catalog section
for a complete listing of locks required by ACSI.
ACSI 1-800-753-5558
HOW TO ORDER (con t . )
2. Modification Number
(Select type of modification required)
Model Description
1510 Fail Safe Control
1520 Fail Secure Control
8. Handing
Model Description
RH Right Hand
LH Left Hand
RHR Right Hand Reverse
LHR Left Hand Reverse
ACCESSORIES
Model Description
1580-1 AC/DC Converter
1580-2 Voltage Regulator
Regulates source voltages up to 30 volts DC (35 volts AC) to a 24VDC output level.
Works with AC or DC source voltages
Can be used with 24VAC/DC rated cylindrical or mortise locks up to 360MA.
UL Listed
ACSI 1-800-753-5558
ACSI Stocks Electric Mortise Lock Bodies available in Schlage, Corbin Russwin, Sargent, Yale, Best,
Falcon, and Dorma. The locks are available in fail safe and fail secure, 24 volt or 12 volt and a variety of
monitoring options.
Model Mortise Lock Body
M1510 L9070B 24VAC/DC Schlage-Fail Safe
M1510 2055B 24VAC/DC Corbin Russwin-Fail Safe
M1510 8237B 24VAC/DC Sargent-Fail Safe
M1510 8808B 24VAC/DC Yale-Fail Safe
M1510 45H75B 24VAC/DC Best-Fail Safe
M1510 MA561B 24VAC/DC Falcon-Fail Safe
M1510 ML9070B 24VAC/DC Dorma-Fail Safe
M1520 L9070B 24VAC/DC Schlage-Fail Secure
M1520 2055B 24VAC/DC Corbin Russwin-Fail Secure
M1520 8237B 24VAC/DC Sargent-Fail Secure
M1520 8808B 24VAC/DC Yale-Fail Secure
M1520 45H75B 24VAC/DC Best-Fail Secure
M1520 MA561B 24VAC/DC Falcon-Fail Secure
M1520 ML9070B 24VAC/DC Dorma-Fail Secure
ELECTRIC MORTISE LOCK BODIES
ACSI Stocks Electric Cylindrical locks available in a Schlage, Sargent, Yale and Corbin Russwin.
Authorized Egress (Request to Exit) and 12 volt options are available.
Model Cylindrical Lock
C1510 ND80B 24VAC/DC Schlage-Fail Safe
C1520 ND80B 24VAC/DC Schlage-Fail Secure
Note: Specify trim style, format and finish. Available in Rhodes, Sparta and Athens trim style. Finishes
available in 626, 625 and 613.
C1510 10G04B 24VAC/DC LL 626 Sargent-Fail Safe
C1510 3357B 24VAC/DC NZD 626 Corbin Russwin-Fail Safe
C1510 5405LNB 24VAC/DC AU 626 Yale-Fail Safe
C1520 10G04B 24VAC/DC LL 626 Sargent-Fail Secure
C1520 3357B 24VAC/DC NZD 626 Corbin Russwin-Fail Secure
C1520 5405LNB 24VAC/DC AU 626 Yale-Fail Secure