ADC Telecommunications DVICSRIU800 800 MHz Remote Interface Unit User Manual manual

ADC Telecommunications Inc 800 MHz Remote Interface Unit manual

manual

Download: ADC Telecommunications DVICSRIU800 800 MHz Remote Interface Unit User Manual manual
Mirror Download [FCC.gov]ADC Telecommunications DVICSRIU800 800 MHz Remote Interface Unit User Manual manual
Document ID159085
Application IDmoA3UQXnDBK4QpwWV/jEHw==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize152.07kB (1900920 bits)
Date Submitted2001-07-10 00:00:00
Date Available2001-07-10 00:00:00
Creation Date2001-05-24 15:25:57
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2001-06-12 13:16:22
Document Titlemanual

FCC ID: F8I-DVICSRIU800
ADCP-75-114
Issue C June 2001
Digivance
Indoor Coverage Solution
800 Mhz Remote Interface Unit User Manual
DRAFT
1145993
ADCP-75-114 • Issue C • June 2001 • Preface
COPYRIGHT
 2001, ADC Telecommunications, Inc.
All Rights Reserved
Printed in the U.S.A.
REVISION HISTORY
ISSUE
DATE
Issue C
06/2001
REASON FOR CHANGE
Original
TRADEMARK INFORMATION
ADC and ADC Telecommunications are registered trademarks of ADC Telecommunications, Inc.
Digivance is a trademark of ADC Telecommunications, Inc.
TORX is a registered trademark of Textron, Inc.
DISCLAIMER OF LIABILITY
Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no
event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims
any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies
to all products, publications and services during and after the warranty period.
This publication may be verified at any time by contacting ADC’s Technical Assistance Center at 1-800-366-3891, extension 63475
(in U.S.A. or Canada) or 952-946-3475 (outside U.S.A. and Canada), or by e-mail to bcg_tac@adc.com.
ADC Telecommunications, Inc.
P.O. Box 1101, Minneapolis, Minnesota 55440-1101
In U.S.A. and Canada: 1-800-366-3891
Outside U.S.A. and Canada: (952) 938-8080
Fax: (952) 946-3292
Page ii
ADCP-75-114 • Issue C • June 2001 • Preface
TABLE OF CONTENTS
Content
Page
DESCRIPTION ....................................................................... 1
1.1
1.2
Mounting .................................................................... 2
1.3
Fault Detection and Alarm Reporting .................................................. 3
1.4
RF Signal Connections ........................................................... 3
1.5
RF Signal Level Adjustments ....................................................... 3
1.6
Powering .................................................................... 3
1.7
Cooling ..................................................................... 3
1.8
User Interface ................................................................. 4
1.9
Specifications ................................................................. 5
INSTALLATION ...................................................................... 7
2.1
Tools and Materials ............................................................. 7
2.2
Unpacking and Inspections ........................................................ 7
2.3
Mounting Procedure ............................................................. 8
2.4
Chassis Ground Connection ........................................................11
2.5
Coaxial Cable Connections ........................................................12
2.6
External Alarm System Connections ..................................................14
2.7
AC Power Connection ............................................................15
OPERATION ........................................................................17
3.1
Primary Functions and Components................................................... 1
Tools and Materials .............................................................17
3.2
Turn-Up Unit and Verify Operation....................................................17
3.3
Forward Path Level Adjustment .....................................................18
3.4
Reverse Path Level Adjustment .....................................................21
MAINTENANCE ......................................................................22
4.1
Tools and Materials .............................................................22
4.2
Fault Detection and Alarm Reporting ..................................................22
4.3
Fan Replacement...............................................................23
CUSTOMER INFORMATION AND ASSISTANCE..................................................25
Page iii
 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001 • Preface
ABOUT THIS MANUAL
This publication provides a description of the Digivance ICS Remote Interface Unit (RIU) plus
instructions for installing the RIU. An overview of the Digivance ICS and a complete
description of the Digital Host Unit (DHU), Digital Remote Unit (DRU) and the Digital
Expansion Unit (DEU) are provided in the Digivance ICS Installation and Operation Manual
(ADCP-75-110). The RIU is an interface device that is used in conjunction with the Digivance
ICS product.
RELATED PUBLICATIONS
Listed below are related manuals and their publication numbers. Copies of these publications
can be ordered by contacting the ADC Technical Assistance Center at 1-800-366-3891
(in U.S.A. or Canada) or 952-946-3000, extension 63475 (outside U.S.A. and Canada).
Title/Description
ADCP Number
Digivance ICS Installation and Operation Manual
ADCP-75-110
Provides an overview of the Digivance ICS, a complete description of the
DHU, DRU, and DEU, system planning and engineering guidelines, DHU
installation instructions, system turn-up and test procedures, and system
troubleshooting and maintenance procedures.
Digivance ICS Digital Expansion Unit Installation Instructions
Provides a description of the DEU and procedures for installing the DEU.
ADCP-75-111
Digivance ICS Digital Remote Unit Installation Instructions
Provides a description of the DRU and procedures for installing the DRU.
ADCP-75-112
Digivance ICS Local Interface Unit User Manual
Provides a description of the LIU and procedures for installing the LIU.
ADCP-75-113
ADMONISHMENTS
Important safety admonishments are used throughout this manual to warn of possible hazards
to persons or equipment. An admonishment identifies a possible hazard and then explains what
may happen if the hazard is not avoided. The admonishments — in the form of Dangers,
Warnings, and Cautions — must be followed at all times. These warnings are flagged by use of
the triangular alert icon (seen below), and are listed in descending order of severity of injury or
damage and likelihood of occurrence.
Danger: Danger is used to indicate the presence of a hazard that will cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
Page iv
 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001 • Preface
Warning: Warning is used to indicate the presence of a hazard that can cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
Caution: Caution is used to indicate the presence of a hazard that will or can cause minor
personal injury or property damage if the hazard is not avoided.
GENERAL SAFETY PRECAUTIONS
Warning: Wet conditions increase the potential for receiving an electrical shock when
installing or using electrically powered equipment. To prevent electrical shock, never install or
use electrical equipment in a wet location or during a lightning storm.
STANDARDS CERTIFICATION
FCC: This equipment complies with the applicable sections of Title 47 CFR Part 22.
UL/CUL: This equipment complies with UL and CUL 1950 Standard for Safety for
Information Technology Equipment, Including Electrical Business Equipment.
IC (Industry Canada): This equipment complies with IC Certification RSS-131.
LIST OF ACRONYMS AND ABBREVIATIONS
The acronyms and abbreviations used in this manual are detailed in the following list:
AC
CUL
DC
DEU
DHU
DRU
EIA
ESD
FCC
IC
ICS
LIU
NOC
RIU
Amperes
Alternating Current
Canadian Underwriters Laboratories
Direct Current
Digital Expansion Unit
Digital Host Unit
Digital Remote Unit
Electronic Industries Association
Electrostatic Discharge
Federal Communications Commission
Industry Canada
Indoor Coverage Solution
Local Interface Unit
Network Operations Center
Remote Interface Unit
Page v
 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001 • Preface
RF
UL
VAC
VDC
WECO
Page vi
 2001, ADC Telecommunications, Inc.
Radio Frequency
Underwriters Laboratories
Volts
Volts Alternating Current
Volts Direct Current
Western Electric Company
ADCP-75-114 • Issue C • June 2001
DESCRIPTION
This section provides a complete description of the Remote Interface Unit (RIU).
1.1 Primary Functions and Components
The RIU, shown in Figure 1, serves as the interfacing unit between a remote BTS and the
Digivance DHU. The RIU provides the following basic functions:
•
RF interface to the BTS (through donor antenna) and DHU
•
Gain adjustments to the forward and reverse path RF signal
•
Duplexing of the forward and reverse path RF signals
•
Alarm reporting to an external alarm system
17.2 INCHES
(437 mm)
11.4 INCHES
(290 mm)
3.5 INCHES
(89 mm)
13.6 INCHES
(345 mm)
16650-A
3.9 INCHES
(99 mm)
MOUNTING
BRACKET
(BOTH SIDES)
FRONT PANEL
CABLE MANAGEMENT
TRAY
Figure 1. Remote Interface Unit
A remote interface between the DHU and the BTS (cell site base station) via a donor antenna
requires specific RF input and output signal levels at the DHU and antenna. The correct levels
at the DHU and antenna can be provided using the RIU. The RIU provides adjustable gain in
both the RF forward and reverse paths. The RIU connects to a directional antenna through a
duplexer which provides separate forward and reverse path connections for the DHU. In the
forward path (downlink), the RIU provides the recommended composite maximum RF input
signal level at the DHU which is –20 dBm. When the level of the RF input signal at the DHU
is –20 dBm, the level of the RF output signal at the DRU is +13 dBm which is the maximum
allowed.
Page 1
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
In the reverse path, the required RF output signal level to the donor antenna will vary
depending on the DRU path loss. When the level of the reverse path (uplink) signal at the DRU
is at the recommended composite maximum level of –40 dBm, the level of the RF output
signal from the DHU is –30 dBm. Therefore, it will generally be necessary to add some gain to
the reverse path signal in order to achieve the required output signal level at the donor antenna.
A block diagram showing a typical remote DHU to BTS interface is provided in Figure 2.
The RIU consists of an electronic circuit board assembly, power supply, duplexer, and linear
power amplifier that are mounted within a powder-coated sheet metal enclosure. The metal
enclosure provides a mounting point for the electronic components, serves as a heat sink, and
controls RF emissions. Except for the fan, the electronic components are not user replaceable.
The RIU is designed for use within a non-condensing indoor environment such as inside a
wiring closet or cabinet. All controls, connectors, and indicators are mounted on the RIU front
panel for convenient access. Cable management functions for the power and coaxial cables are
provided by a cable management tray that extends outward from the RIU front panel.
DIRECTIONAL
ANTENNA TO/FROM
CELL SITE BTS
REVERSE
(UPLINK)
DIRECTIONAL ANTENNA
TO/FROM HANDSETS
FORWARD
(DOWNLINK)
+13 dBm
(COMPOSITE
MAX)
-20 dBm
(COMPOSITE
MAX)
OPTICAL LINK
DIGITAL
HOST
UNIT
REMOTE
INTERFACE
UNIT
-30 dBm
(COMPOSITE
MAX)
-40 dBm
(COMPOSITE
MAX)
DIGITAL
REMOTE
UNIT
OPTICAL LINK
16425-A
Figure 2. Remote BTS Interface Block Diagram
Two versions of the 800 Mhz RIU are available. One version is used to interface with an Aband BTS and the other version is used to interface with a B-band BTS. The frequency (800
Mhz) and band (A or B) are clearly marked on a label attached to the RIU cable management
tray.
1.2 Mounting
The RIU may be used in both rack-mount and wall-mount applications. For rack mount
applications, a pair of reversible mounting brackets is provided that allow the RIU to be mounted
in either a 19-inch or 23-inch EIA or WECO equipment rack. When rack-mounted, the front
panel of the RIU is flush with the front of the rack. The cable management tray extends 3.9
inches (99 mm) beyond the front panel. Fasteners are provided for rack-mount applications.
For wall-mount applications, a pair of holes is provided in the cable management tray which
allow the RIU to be mounted on any flat vertical surface. The mounting brackets may also be
removed and reinstalled is such a way as to be used to secure the RIU to a flat vertical surface.
The RIU should be oriented with the front panel facing upward when wall-mounted. The
fasteners must be provided by the installer in wall-mount applications.
Page 2
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
1.3 Fault Detection and Alarm Reporting
The RIU is designed to detect a power amplifier over or under current condition and a high
temperature condition. A single front panel Light Emitting Diode (LED) indicator turns from
green to red or yellow if a fault is detected. A set of alarm contacts (normally open and
normally closed) are also provided for reporting an alarm to an external alarm system when a
fault is detected. Both major alarm (power amplifier over/undercurrent condition or power
failure) and minor alarm (high temperature) contacts are provided.
1.4 RF Signal Connections
The RF signal connections between the RIU and DHU are supported through a pair of type N
female connectors mounted on the RIU front panel. One connector is used for connecting the
forward path coaxial cable and the other connector is used for connecting the reverse path coaxial
cable. The RF signal connection between the RIU and the donor antenna is supported through a
single type N female connector. The single connector is used for connecting the coaxial jumper
cable that links the RIU to the donor antenna. The DHU cannot be connected directly to a donor
antenna and requires an interface device such as the RIU.
Note: To comply with Maximum Permissible Exposure (MPE) requirements, antennas must be
installed to provide at least 20 centimeters (8 inches) of separation from all persons per FCC
47 CFR part 2.1091.
1.5 RF Signal Level Adjustments
The RIU is equipped with two digital attenuators for adjusting the signal levels of the forward
and reverse path RF signals. The attenuators provide an attenuation adjustment range of 0 to 31
dB and can be set in 1 dB increments. In the forward path, this range provides a maximum
gain of +40 dB (with attenuator set to 0) or a minimum gain of +9 dB (with attenuator set to 31
dB). In the reverse path, this range provides a maximum gain of +59 dB (with attenuator set
to 0) or a minimum gain of +28 dB (with attenuator set to 31 dB). Each attenuator is adjustable
by means of two rotary switches which are mounted behind the RIU front panel. Access to
each rotary switch is through a small hole. A small screwdriver is required to adjust the switch
setting. Turning each switch adds or removes attenuation and therefore adjusts the signal level
of the specified signal path.
1.6 Powering
The RIU is powered by 120/240 VAC (50–60 Hz) power which is supplied through a standard
three-conductor AC power cord. The power cord is provided with the RIU and is 98 inches
(2.5 meters ) long. A resetable circuit breaker/On-Off switch is provided at the unit front panel.
The switch applies power to the RIU internal power supply.
1.7 Cooling
Continuous air flow for cooling is provided by a fan mounted on the right side of the housing.
A minimum of 3 inches (76 mm) of clearance space must be provided on both the left and right
sides of the RIU for air intake and exhaust. An alarm is provided that indicates if a high
temperature condition (>58º C/136º F) occurs. The fan may be field-replaced if it fails.
Page 3
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
1.8 User Interface
The RIU user interface consists of the various connectors, switches, terminals, and LED that
are provided on the RIU front panel. The RIU user interface points are indicated in Figure 3
and described in Table 1.
(2) AC POWER
ON/OFF SWITCH
(4) REVERSE LEVEL
ADJUSTMENT
SWITCHES
(6) FORWARD
RF OUTPUT
CONNECTOR
(7) REVERSE
RF INPUT
CONNECTOR
16651-A
(1) ANTENNA
CONNECTOR
(3) AC POWER CORD
CONNECTOR
NOTE: SHOWN WITHOUT
CABLE MANAGEMENT TRAY
(5) FORWARD LEVEL
ADJUSTMENT
SWITCHES
(8) ALARM LED
INDICATOR
(9) ALARM
CONNECTOR
Figure 3. Remote Interface Unit User Interface
Table 1. Remote Interface Unit User Interface
REF
No.
USER INTERFACE
DESIGNATION
DEVICE
FUNCTIONAL DESCRIPTION
ANTENNA
N-type female RF
coaxial connector
Used for connecting the donor antenna
coaxial cable.
I/O
I/O rocker switch/
circuit breaker
Provides AC power On/Off control and AC
power over current protection.
POWER
3-wire AC power
cord connector
Used for connecting the AC power cord.
REV LEVEL ADJ
Rotary switch
Used to adjust the reverse path RF signal
level by adding or removing attenuation.
Rotary switch
Used to adjust the forward path RF signal
level by adding or removing attenuation.
MSB
LSB
FWD LEVEL ADJ
MSB
LSB
FORWARD OUT
N-type female RF
coaxial connector
Used for connecting the RIU to DHU
forward path coaxial cable.
REVERSE IN
N-type female RF
coaxial connector
Used for connecting the DHU to RIU
reverse path coaxial cable.
ALARMS
Multi-colored LED
(Red/Green/Yellow)
Indicates if the RIU is normal or faulty. (see
Section 3 for a detailed description)
MINOR
Screw-type terminal
connector (14–26
AWG)
Used for connecting the RIU to an external
alarm system. Includes normally open (NO),
normally closed (NC), and common (COM)
wiring connections.
MAJOR
Page 4
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
1.9 Specifications
The specifications for the RIU are provided in Table 2. All specifications apply after a five
minute warm-up period.
Table 2. Remote Interface Unit Specifications
PARAMETER
SPECIFICATION
Environmental
Operating Temperature
0º to 50º C (32º to 122º F)
Storage Temperature
–30º to +70º C (–22 to 158º F)
Humidity
No condensation
Weather resistance
Indoor installation only
REMARKS
RF Forward Path
A-band frequency range
869 to 891.5 MHz
B-band frequency range
880-894 MHz
RF Gain
+9 to +40 dB
Adjustable in 1 dB steps
Gain Variation
± 1.5 dB
Over frequency, temperature,
and unit-to-unit.
Gain stepsize accuracy
± (0.2 + 3% of gain setting in dB)
dB
Output power
–20 dBm composite maximum to
Digivance ICS input
With proper attenuation setting
Input level
–29 dBm composite maximum
To drive Digivance ICS DHU
VSWR
1.5:1 or better, both ports
IP3
> +30 dBm
RF Reverse Path
A-band frequency range
824 to 835 and 845 to 846.5 MHz
B-band frequency range
835 to 849 MHz
RF Gain
+29 to +59 dB
Adjustable in 1 dB steps
Gain Variation
±1.5 dB
Over frequency, temperature,
and unit-to-unit.
Gain stepsize accuracy
± (0.2 + 3% of gain setting in dB)
dB
Output power
+ 29 dBm composite maximum
When driven with Digivance
ICS DHU
Input level
–30 dBm composite maximum
From Digivance ICS DHU
output
VSWR
1.5:1 or better, both ports
IP3
> +46 dBm
Continued
Page 5
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
Table 2. Remote Interface Unit Specifications (Continued)
PARAMETER
SPECIFICATION
REMARKS
Physical
Weight
20.2 lbs (8.7 kg)
Dimensions (H×W×D)
3.5 × 19.0 × 17.25 Inches
(89 × 482 × 438 mm)
Color
Putty white
RF connections
Type N
Female
Alarm connection
Screw terminals (14–26 AWG)
NO, NC, and COM
Reliability
MTBF 80,000 hours
Electrical
Power source
120–240 VAC, 50–60 Hz
AC Connection
IEC 320
Male
Power consumption
250 W
Maximum
Current rating
85–250 VAC, 2 Amp input
Donor Antenna
Type
Directional
Gain
15 dB or greater
Page 6
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
INSTALLATION
This section provides the installation procedures for the RIU. Installation of the various
Digivance ICS units may proceed separately from the installation of the RIU.
2.1 Tools and Materials
The following tools are required in order to complete the procedures in this section:
•
Box cutter
•
Pencil or scribe
•
Medium and small size flat-bladed screwdrivers
•
Phillips screwdriver (#2)
•
TORX screwdriver (T20)
•
Wire cutters
•
Wire stripper
•
Tool kit for attaching N-type male connectors to coaxial cable
•
Drill and assorted drill bits (wall-mount installations only)
The following materials are required in order to complete the procedures in this section:
•
Wall-mount fasteners (wall-mount applications only)
•
#22 AWG (0.40 mm) category 3 or 5 cable (for external alarm connections)
•
#18 AWG (1.00 mm) insulated stranded copper wire (for chassis grounding wire)
•
Ring terminal for #18 wire (for chassis ground wire connection)
•
High performance, flexible, low loss 50-ohm coaxial cable
•
N-type male connectors
•
Wire ties
2.2 Unpacking and Inspection
This sub-section provides instructions for opening the shipping boxes, verifying that all parts
have been received, and verifying that no shipping damage has occurred. Use the following
procedure to unpack and inspect the RIU:
1. Open the shipping carton and carefully unpack the RIU from the protective packing
material.
2. Check the RIU for broken or missing parts. If there are any damages, contact ADC (see
section 5 at the end of this manual) for an RMA (Return Material Authorization) and to
reorder if replacement is required.
Page 7
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
2.3 Mounting Procedure
The RIU may be either rack-mounted or wall-mounted. Of the procedures that follow, use
whichever procedure is appropriate for the installation.
2.3.1
Rack-Mount Installation
The RIU may be mounted in either a 19-inch or 23-inch EIA or WECO equipment rack. Both
US standard and metric machine screws are included for rack mounting the RIU. When
loading the RIU in a rack, make sure the mechanical loading of the rack is even to avoid a
hazardous condition such as a severely unbalanced rack. The rack should safely support the
combined weight of all the equipment it holds. In addition, the maximum recommended
ambient temperature for the RIU is 50º C (122º F). Allow sufficient air circulation or space
between units when the RIU is installed in a multi-unit rack assembly because the operating
ambient temperature of the rack environment might be greater than room ambient.
Warning: Wet conditions increase the potential for receiving an electrical shock when
installing or using electrically-powered equipment. To prevent electrical shock, never install
or use electrical equipment in a wet location or during a lightning storm.
Use the following procedure to install the RIU in the equipment rack:
1. The RIU is shipped with the mounting brackets installed for 19-inch rack installations. If
mounting the RIU in a 19-inch rack, proceed to step 4. If mounting the RIU in a 23-inch
rack, proceed to step 2.
2. Remove both mounting brackets from the RIU (requires TORX screwdriver with T20 bit).
3. Reinstall both mounting brackets so the long side of the bracket is flush with the RIU
front panel as shown in Figure 4. Use the screws removed in step 2 to re-attach the
brackets to the RIU enclosure.
REMOVE AND REINSTALL MOUNTING
BRACKETS AS SHOWN FOR
INSTALLATION IN 23-INCH RACKS
16487-B
Figure 4. Installing the Mounting Brackets for 23-Inch Rack Installations
Page 8
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
4. Position the RIU in the designated mounting space in the rack (per system design) and
then secure the mounting brackets to the rack using the four machine screws provided
(use #12-24 screws or M6 x 10 screws, whichever is appropriate) as shown in Figure 5.
Note: Provide a minimum of 3 inches (76 mm) of clearance space on both the left and right
sides of the RIU for air intake and exhaust.
16483-B
Figure 5. RIU Rack Mount Installation
2.3.2
Wall-Mount Installation
The RIU may be mounted from any flat vertical surface. It is recommended that a backer board
such as 3/4-inch plywood be applied over the mounting surface to provide a secure base for
attaching the RIU. Two mounting holes are provided in the cable management tray for securing
the RIU to the mounting surface. In addition, the mounting brackets may be removed and then
reinstalled in such a way that they can be used for securing the RIU to the mounting surface.
Either method for mounting may be used at the discretion of the installer. The fasteners must be
provided by the installer. Use the following procedure to wall-mount the RIU:
Warning: Wet conditions increase the potential for receiving an electrical shock when
installing or using electrically-powered equipment. To prevent electrical shock, never install
or use electrical equipment in a wet location or during a lightning storm.
1. Obtain the appropriate fasteners (lag bolts, screw anchors, etc.) for securing the RIU to
the mounting surface.
2. If the mounting brackets will be used to secure the RIU to the mounting surface, proceed
to step 3. If the mounting brackets will not be used to secure the RIU to the mounting
surface, skip steps 3 and 4 and proceed to step 5.
Page 9
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
3. Remove both mounting brackets from the RIU (requires TORX screwdriver with T20 bit).
4. Reinstall both mounting brackets so the short side of the bracket is flush with the bottom
of the RIU as shown in Figure 6. Use the screws removed in step 3 to re-attach the
brackets to the RIU enclosure.
16484-B
Figure 6. Installing the Mounting Brackets for Wall-Mount Installation
5. Position the RIU on the mounting surface in the specified location (per the system
design) with the front panel facing up as shown in Figure 7.
Note: Provide a minimum of 3 inches (76 mm) of clearance space on both the left and right
sides of the RIU for air intake and exhaust.
6. Using the RIU as a template, mark the location of the mounting holes on the mounting
surface.
Note: The mounting holes in the RIU cable management tray are spaced 11-21/32 inches
(296 mm) center to center.
7. Set the RIU aside and then drill appropriately sized holes in the mounting surface for the
fasteners.
8. If using only the mounting brackets to secure the RIU to the mounting surface, skip step
9 and proceed to step 10. If using the cable management tray mounting holes to secure
the RIU to the mounting surface, proceed to step 9.
9. Partially install the fasteners for the cable management tray mounting holes. Leave the
head of each fastener protruding about 1/4 inch (6 mm) from the mounting surface.
10. Hang the RIU from the fasteners installed in step 9 or position the RIU for installation if
using only the mounting brackets.
11. Install and securely tighten all fasteners.
Page 10
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
BACKER BOARD SUCH
AS 3/4-INCH PLYWOOD
16486-B
Figure 7. RIU Wall-Mount Installation
2.4 Chassis Ground Connection
A stud is provided on the rear side of the chassis for connecting a grounding wire to the
chassis. Use the following procedure to connect the grounding wire to the chassis and to route
the grounding wire to an approved earth ground source:
1. Obtain a length of #18 AWG (1.00 mm) insulated stranded copper wire for use as a
chassis grounding wire.
2. Terminate one end of the wire with a ring terminal.
3. Locate the chassis ground stud at the rear of the RIU as shown in Figure 8.
4. Attach the ring end of the wire to the chassis ground stud (see Figure 8).
5. Route the free end of the chassis grounding wire to an approved (per local code or
practice) earth ground source.
Page 11
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
16169-A
Figure 8. Chassis Ground Stud
6. Cut the chassis grounding wire to length and connect it to the approved ground source as
required by local code or practice.
Note: Be sure to maintain reliable grounding for rack and wall mounted equipment. Pay
particular attention to ground source connections.
2.5 Coaxial Cable Connections
The RF signal connections between the RIU and DHU are supported through a pair of type N
female connectors mounted on the RIU front panel. One connector is used for connecting the
forward path coaxial cable and the other connector is used for connecting the reverse path
coaxial cable. The RF signal connection between the RIU and the donor antenna is supported
through a single type N female connector. The single connector is used for connecting the
coaxial jumper cable that links the RIU to the donor antenna.
2.5.1
Forward and Reverse Path Coaxial Cable Connections
Use the following procedure to install the forward and reverse path coaxial cables that link the
RIU to the DHU:
1. Locate the forward and reverse path coaxial cables that were routed to the RIU from the
DHU.
Note: The procedures for routing the reverse and forward path coaxial cables from the
DHU to the RIU and for connecting the cables to the DHU are covered in the Digivance
ICS Installation and Operation Manual (ADCP-75-110) which is provided with the DHU.
2. Terminate each cable with a type N male connector following the connector supplier’s
recommendations.
3. Connect the forward path cable to the FORWARD OUT connector on the RIU front
panel as shown in Figure 9.
Page 12
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
FORWARD OUT
CONNECTOR
TYPE-N MALE CONNECTOR
16652-A
REVERSE IN
CONNECTOR
Figure 9. FORWARD OUT and REVERSE IN Coaxial Cable Connections
4. Connect the reverse path cable to the REVERSE IN connector on the RIU front panel as
shown in Figure 9.
5. Dress and secure cables at the RIU.
2.5.2
Antenna Coaxial Cable Connection
Use the following procedure to install the coaxial cable that links the RIU to the donor
antenna:
Note: To comply with Maximum Permissible Exposure (MPE) requirements, antennas must be
installed to provide at least 20 centimeters (8 inches) of separation from all persons per FCC
47 CFR part 2.1091.
1. Obtain the required length of high performance, flexible, low loss 50-ohm coaxial
communications cable for the antenna coaxial connection.
2. Route the coaxial cable between the RIU and the donor antenna (per system design) and
cut to the required length. Allow sufficient slack for dressing and organizing cables at the
RIU and antenna.
3. Terminate each cable end with a type N male connector following the connector
supplier’s recommendations.
4. Connect the RIU end of the antenna cable to the ANTENNA connector on the RIU front
panel as shown in Figure 10.
5. Connect the antenna end of the antenna cable to the donor antenna.
6. Dress and secure cables at the RIU and donor antenna.
Page 13
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
ANTENNA
CONNECTOR
16653-A
TYPE-N MALE CONNECTOR
Figure 10. RIU Antenna Cable Connection
2.6 External Alarm System Connections
The alarm interface between the RIU and an external alarm system is supported by a sixterminal plug (with screw-type terminals) that connects to a receptacle on the RIU front panel.
The terminal plug provides connections to normally open (NO) and normally closed (NC) dry
type alarm contacts for both minor and major alarms. A category 3 or 5 cable is typically used
to connect the RIU to the external alarm system. Use the following procedure to install the
alarm wiring and connect it to the RIU:
1. Obtain the required length of category 5 cable.
2. Route the cable between the RIU and the external alarm system (if not already routed)
and then cut to required length. Allow sufficient slack for dressing and organizing the
cable at the RIU.
3. Strip back the outer cable sheath and insulation to expose the wires at both ends of the
cable and strip back 0.2 inches (5 mm) of insulation each wire.
4. Connect the Major alarm wire pair to the MAJOR COM/NC or MAJOR COM/NO
terminals (whichever is required by the external alarm system) on the RIU alarm terminal
connector (supplied with RIU) as shown in Figure 11.
Page 14
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
ALARM
CONNECTOR
MINOR
ALARM
WIRES
MAJOR
ALARM
WIRES
ALARM CONNECTOR
DETAIL
16482-B
Figure 11. External Alarm System Connections
5. Connect the Minor alarm wire pair to the MINOR COM/NC or MINOR COM/NO
terminals (whichever is required by the external alarm system) on the RIU alarm terminal
connector as shown in Figure 11.
6. Connect the Major and Minor alarm wire pairs to the appropriate terminals on the
external alarm system.
7. Dress and secure cable.
2.7 AC Power Connection
The AC power interface between the RIU and the AC power source is supported by a 3-wire
AC power cord connector located on the RIU front panel. The AC connector provides a
connection point for the power cord which is provided separately with the RIU. Use the
following procedure to install the AC power cord:
1. Place the RIU AC power ON/OFF switch, shown in Figure 12, in the OFF position
(press O).
Page 15
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
16654-A
AC POWER CORD
Figure 12. AC Power Connection
2. Locate the AC power cord which is provided separately with the RIU. Use only the AC
power cord provided with the RIU or an equivalent UL listed and CSA certified 3conductor, 18 AWG cord terminated in a molded-on plug cap rated 125 V, 15 A with a
minimum length of 6 feet (1.8 m).
Note: The RIU is intended to be used with a 3-wire grounding type plug which has a
grounding pin. Equipment grounding is to ensure safe operation. Do not defeat the
grounding means. Verify RIU is reliably grounded when installed.
3. Connect the receptacle end of the power cord to the AC connector on the RIU.
4. Route the plug end of the power cord to the specified AC outlet (per the system design)
and connect plug to outlet.
Warning: The current rating of the RIU is 2 Amps at 120 VAC. Avoid overloading circuits
which may cause damage to over-current protection devices and supply wiring.
5. Dress and secure cable.
6. When the RIU installation is complete, refer to Section 3 of this manual for the unit turnup and test procedures.
Page 16
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
OPERATION
This section provides guidelines for turning-up the RIU, verifying that the RIU is operating
properly, setting the forward and reverse path signal levels, and correcting any installation
problems.
3.1 Tools and Materials
The following tools and materials are required in order to complete the procedures in this section:
•
Portable spectrum analyzer or network analyzer
•
Pencil or pen
•
Writing pad
3.2 Turn-Up Unit and Verify Operation
The process of turning-up the RIU and verifying operation involves setting the forward and
reverse path signal levels, turning on the power, verifying that the LED indicator shows normal
operation, and then measuring the forward and reverse path signal levels. Refer to Table 3 for a
detailed description of the ALARM LED indicator.
Table 3. Remote Interface Unit LED Indicator
INDICATOR
COLOR
DESCRIPTION
Green
Indicates if the RIU is normal or if a fault is detected.
RIU in normal state, no faults detected.
Yellow
Red
High temperature fault detected. (Minor alarm)
Over or undercurrent fault on power amplifier detected. (Major alarm)
ALARM
Off
AC power off or RIU internal fault.
Use the following procedure to power-up the system:
1. Temporarily disconnect the alarm system or notify the alarm system provider that testing
is in progress.
2. Adjust the forward and reverse path signal levels as specified in sections 3.3 and 3.4.
3. Verify that the donor antenna is properly installed and connected.
Note: To comply with Maximum Permissible Exposure (MPE) requirements, antennas must be
installed to provide at least 20 centimeters (8 inches) of separation from all persons per FCC
47 CFR part 2.1091.
4. Verify that the RIU is connected to the appropriate AC outlet.
5. Place the ON/OFF switch on the RIU in the ON position (press I).
6. Verify that the ALARM LED on the RIU turns green.
7. Check the forward path RF signal level at the DHU RF IN port and verify that the DHU
input signal level is –20 dBm. Re-adjust FWD LEVEL ADJ rotary switches to add or
remove gain if required.
Page 17
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
8. Check the reverse path RF signal level at the antenna and verify that the signal level is
correct per the system design. Re-adjust REV LEVEL ADJ rotary switches to add or
remove gain if required.
9. Reconnect the alarm system or notify the alarm system provider that testing is complete.
3.3 Forward Path Level Adjustment
The level of the composite RF output signal from the donor antenna will vary depending on the
gain of the antenna and the number of channels present. To interface with the DHU, the
forward path signal level must be adjusted to provide a –20 dBm composite (maximum) input
signal to the DHU. Use the following procedure to adjust the RIU to provide the required
forward path signal level at the DHU:
1. Connect a spectrum analyzer or power meter to the antenna connector. The required
signal levels and test points are shown in Figure 13.
DIRECTIONAL
ANTENNA TO/FROM
CELL SITE BTS
MEASURE RF LEVEL
OF A SINGLE CARRIER
AT ANTENNA OUTPUT
CHECK SYSTEM DESIGN
SPECIFICATIONS FOR RF LEVEL
REQUIRED AT DONOR ANTENNA
-20 dBm REQUIRED
AT INPUT TO DHU
(COMPOSITE MAX) FORWARD
(DOWNLINK)
DIRECTIONAL ANTENNA
TO/FROM HANDSETS
+13 dBm
(COMPOSITE
MAX)
-40 dBm
(COMPOSITE
MAX)
OPTICAL LINK
DIGITAL
HOST
UNIT
REMOTE
INTERFACE
UNIT
DIGITAL
REMOTE
UNIT
OPTICAL LINK
-30 dBm OUTPUT
FROM DHU
(COMPOSITE MAX)
REVERSE
(UPLINK)
16655-A
Figure 13. Signal Levels and Test Points
2. Measure the RF level of a single carrier, such as the control channel, in dBm. Make sure
the resolution bandwidth of the spectrum analyzer or power meter is narrow enough to
measure the power of the single 30 kHz channel only.
3. Verify that all carriers are coming in at equal power at bandwidth.
4. Calculate the total composite signal output power from the antenna using the following
formula:
Ptot = Pc+10 LogN
Where,
Ptot is the total composite power in dBm
Pc is the power per carrier in dBm as measured in step 2, and
N is the total number of channels.
Page 18
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
5. Determine the total cable loss that is imposed by the coaxial cable that links the antenna
to the RIU and by the forward path coaxial cable that links the RIU to the DHU.
6. Subtract the total cable loss from the total composite power calculated in step 4.
7. Subtract –20 (the composite maximum input signal level required at the DHU) from the
amount determined in step 6. The difference equals the total amount of gain required to
raise the forward path signal level to the –20 dBm level required by the DHU. The result
should be negative which indicates that gain is required. The following formula outlines
the required calculations:
Ptot – CLtot – (–20) = Amount of gain (should be negative) required.
Where;
Ptot is the total composite power in dBm (step 4)
CLtot is the total cable loss (step 5)
–20 is the composite maximum input signal level required at the DHU
8. Using a small screwdriver, adjust the FWD LEVEL ADJ rotary switches to insert the
gain required (as determined in step 7) to provide a –20 dBm signal at the DHU. Refer to
Figure 14 for a description of how the rotary switches work and to Table 4 for the
adjustment settings.
Note: The RIU provides a forward path signal adjustment range of from +9 dB to +40 dB.
9. Disconnect the spectrum analyzer or power meter from the antenna.
FWD LEVEL ADJ
REV LEVEL ADJ
MSB
LSB
MSB
LSB
14 0 2
12
10 8 6
14 0 2
12
10 8 6
16
16
16649-A
INSERT A SMALL SCREWDRIVER INTO THE SLOT.
ROTATE THE SWITCH UNTIL THE WHITE ARROW IS
ALIGNED WITH THE REQUIRED SETTING.
Figure 14. Rotary Switch Adjustment
Page 19
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
Table 4. RIU Rotary Switch Adjustment Settings
REVERSE GAIN SETTINGS
FORWARD GAIN SETTINGS
GAIN
(+dB)
MSB
SETTING
LSB
SETTING
GAIN
(+dB)
MSB
SETTING
LSB
SETTING
59
40
58
39
57
38
56
37
55
36
54
35
53
34
52
33
51
32
50
31
49
10
30
10
48
11
29
11
47
12
28
12
46
13
27
13
45
14
26
14
44
15
25
15
43
16
24
16
42
16
23
16
41
16
22
16
40
16
21
16
39
16
20
16
38
16
19
16
37
16
18
16
36
16
17
16
35
16
16
16
34
16
15
16
33
16
10
14
16
10
32
16
11
13
16
11
32
16
12
12
16
12
30
16
13
11
16
13
28
16
14
10
16
14
28
16
15
16
15
Page 20
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
3.4 Reverse Path Level Adjustment
The level of the composite RF signal that should be input to the antenna will vary depending
on the maximum acceptable DRU path loss per the system design. The design objective is for
the Digivance system to provide unity gain. Use the following procedure to adjust the RIU to
provide the required reverse path signal level at the antenna:
1. Determine the maximum acceptable DRU path loss per the system design specifications.
2. Determine the total gain provided by the DRU antenna and the donor antenna.
3. Determine the total cable loss that is imposed by the reverse path coaxial cable that links
the DHU to the RIU and the coaxial cable that links the RIU to the antenna.
4. Calculate the total gain that must be added by the RIU using the following formula:
RIU Gain = DRU path loss + Cable loss – DHU gain (10 dB) – Antenna Gain
The result should be negative which indicates that gain is required.
5. Using a small screwdriver, adjust the REV LEVEL ADJ rotary switches to insert the gain
required as determined in step 4. Refer to Figure 14 for a description of how the rotary
switches work and to Table 4 for the adjustment settings.
Note: The RIU provides a reverse path signal adjustment range of from +28 dB to +59 dB.
Page 21
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
MAINTENANCE
This section explains the alarm reporting system, provides a method for isolating and
troubleshooting faults, and provides procedures for replacing the cooling fan.
The RIU requires no regular maintenance to insure continuous and satisfactory operation.
Maintenance, as it applies to the RIU, primarily involves diagnosing and correcting service
problems as they occur. When an alarm is reported, it will be necessary to follow a systematic
troubleshooting procedure to locate the problem. Once the source of the problem is isolated,
the appropriate corrective action can be taken to resolve the problem. The only component that
can be replaced is the cooling fan. The failure of any other component within the RIU requires
replacement of the RIU.
4.1 Tools and Materials
The following tools and materials are required in order to complete the procedures in this
section:
•
ESD wrist strap
•
Small size flat-bladed screwdriver
•
TORX screwdriver (T10)
4.2 Fault Detection and Alarm Reporting
Detection of a fault by the RIU generates an external alarm response. An ALARM LED
indicator is provided on the RIU front panel to visually indicate when a fault is detected. In
addition, normally open (NO) and normally closed (NC) dry alarm contacts are provided to
report minor and major alarms to an external alarm system. A minor alarm is defined as a
high temperature condition. A major alarm is defined as a power amplifier over/undercurrent
condition.
When the RIU alarm contacts are connected to an external alarm system, detection of a fault
will generate an alarm at the Network Operations Center (NOC). Whenever a problem is
reported, refer to Table 5 to isolate and correct the fault.
Table 5. Fault Isolation and Troubleshooting
Alarm Type:
Minor
ALARM Indicator: Yellow:
POSSIBLE CAUSE
CORRECTIVE ACTION/COMMENTS
1. Air intake or exhaust openings to RIU
chassis blocked.
2. Ambient temperature > 58º C/136º F.
3. Faulty fan.
1. Remove cause of air-flow blockage.
2. Reduce ambient temperature.
3. Replace fan (see Subsection 4.3).
Continued
Page 22
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
Table 5. Fault Isolation and Troubleshooting, Continued
Alarm Type:
Major
ALARM Indicator: Red:
POSSIBLE CAUSE
CORRECTIVE ACTION/COMMENTS
1. Over or undercurrent condition detected at
power amplifier
1. Replace RIU.
Alarm Type:
Major
ALARM Indicator: Off:
POSSIBLE CAUSE
CORRECTIVE ACTION/COMMENTS
1. AC power source off or disconnected.
2. Faulty RIU
1. Restore AC power.
2. Replace RIU.
4.3 Fan Replacement
It is recommended that the fan (catalog number DGVI-200000FAN) be replaced every five years.
Replacement of a fan requires that the RIU be turned off for a short period of time. This will drop
all existing calls, cause a temporary loss of service, and generate a major alarm. Use the following
procedure to replace the RIU cooling fan:
1. Before touching the RIU or handling a fan, slip on an Electro-Static Discharge (ESD)
wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist
strap while completing each section of the fan installation procedure.
Warning: Electronic components can be damaged by static electrical discharge. To prevent
ESD damage, always wear an ESD wrist strap when working on the RIU and when handling
electronic components.
2. Notify the NOC or alarm monitoring system operator that the system is going offline.
3. Place the RIU AC power On/Off switch in the OFF position (press O) and disconnect the
AC power cord.
Caution: High voltage components are present within the RIU enclosure. Disconnect the AC
power cord from the AC power source before proceeding to step 4.
4. Remove the four flat-head screws (requires TORX screwdriver with T15 bit) that secure the
fan/grill assembly to the side of the enclosure as shown in Figure 15 and save for reuse.
5. Carefully withdraw the fan/grill assembly from the enclosure until the wiring harness is
exposed and the connector is accessible.
6. Lift the small latch on the wiring harness connector (see Figure 15) and carefully unplug
the connector from the circuit board connector.
7. Remove the four plastic rivets that secure the faulty fan to the grill by pushing outward
on rivet center post until the rivet can be withdrawn from the grill as shown in Figure 16.
8. Remove the fan from the grill and then locate the replacement fan.
9. Use the rivets removed in step 7 to secure the replacement fan to the grill. Orient the fan
so the wiring harness is on the right side (side of fan that faces toward back of enclosure
when installed) and the arrow on the fan housing faces into the enclosure.
Page 23
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
LATCH
16637-A
Figure 15. Fan/Grill Assembly Removal
16485-B
Figure 16. Removing Fan From Grill
10. Connect the wiring harness connector to the circuit board connectors.
11. Route the wiring harness under the fan.
12. Secure the fan/grill assembly to the side of the enclosure (see Figure 15) using the four
flat-head screws removed in step 4.
13. Reconnect the AC power cord and place the RIU AC power On/Off switch in the ON
position (press I).
14. Verify that the fan runs properly following power up.
15. Notify the NOC or alarm monitoring system operator that the system is going back
online.
Page 24
© 2001, ADC Telecommunications, Inc.
ADCP-75-114 • Issue C • June 2001
CUSTOMER INFORMATION AND ASSISTANCE
For customers wanting information on ADC products or help in using them, ADC offers the
services listed below. To obtain any of these services by telephone, first dial the central ADC
telephone number, then dial the extension provided below.
The central number for calls originating in the U.S.A. or Canada is 1-800-366-3891. For calls
originating outside the U.S.A. or Canada, dial country code “1” then dial 952-946-3000.
Sales Assistance
Extension 63000
• Quotation Proposals
• Ordering and Delivery
• General Product Information
Systems Integration
Extension 63000
•
•
•
•
•
•
•
Complete Solutions (from Concept to Installation)
Network Design and Integration Testing
System Turn-Up and Testing
Network Monitoring (Upstream or Downstream)
Power Monitoring and Remote Surveillance
Service/Maintenance Agreements
Systems Operation
BCG Technical Assistance Center
Extension 63475
E-Mail: bcg_tac@adc.com
•
•
•
•
•
•
Technical Information
System/Network Configuration
Product Specification and Application
Training (Product-Specific)
Installation and Operation Assistance
Troubleshooting and Repair
Product Return Department
Extension 63748
E-Mail: repair&return@adc.com
• ADC Return Authorization number and instructions must
be obtained before returning products.
Product information may also be obtained using the ADC web site at www.adc.com or by
writing ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, MN 55440-1101, U.S.A.
Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no
event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further
disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of
liability applies to all products, publications and services during and after the warranty period.
This publication may be verified at any time by contacting ADC’s Technical Assistance Center at 1-800-366-3891, extension 63475
(in U.S.A. or Canada) or 952-946-3475 (outside U.S.A. and Canada), or by e-mail to bcg_tac@adc.com.
© 2001, ADC Telecommunications, Inc.
All Rights Reserved
Printed in U.S.A.
Page 25

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2001:05:24 15:25:57
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2001:06:12 13:16:22-05:00
Page Count                      : 31
EXIF Metadata provided by EXIF.tools
FCC ID Filing: F8I-DVICSRIU800

Navigation menu