Get I nform at ion  Page 110 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Viewing the Alarms ReportTo access the Current Alarms report, in the Syst em  Menu bar, click System Information>  Get Information, and then in the Reports panel Type list, select  Alarms.The Current Alarms table provides the following inform ation:•Severity—whet her alarm  is classified as Maj or or Minor.•Ack’d—whether the alarm  has been acknowledged, as indicat ed by a checkm ark.•Alarm Code—syst em -assigned alarm  code. See “ Troubleshoot ing Alarm s”  on page 185 or use t he “ I ndex of Alarm s”  on page 313 to find t he page num ber for a specific alarm  description, which includes t he alarm  code.•Alarm Name—descriptive nam e of alarm .•Timestamp—dat e and tim e when the alarm  occurred (YYYY:MM:DD:HH:MM:SS)•Unit Id—ident ifies the unit  wit hin t he syst em ;  see “ Unit  I dentificat ion”  on page 43.•Unit Type—what  t he unit is, such as Host  or Rem ot e•Unit Name—nam e assigned t o the unit•Module—type of m odule wit hin the specified unit  t hat  is experiencing t he alarm  ( SeRF, DART, Power Det ect or, SFP)•Module Name—user- assigned nam e for t he m odule t hat assist s in ident ifying m odules when t roubleshoot ing•RF Band—type of passband provided by t he DART ( if applicable)
Syst em  I nform at ionFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 111ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.•Extended Info—link t hat  provides furt her inform at ion on the alarm , including troubleshoot ing inform at ion.IFEU + RAU ReportThe  IFEU + RAU report  pert ains t o an I nt erReach Spectrum  system  and is not applicable t o t his release.
Get I nform at ion  Page 112 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Viewing the All ReportThe All Report  consolidat es all available report s into a single web page.
Syst em  I nform at ionFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 113ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Downloading a ReportCAUTION! The All Report or Analog Units Report can take several minutes to download.You can download the reports t o your laptop in Windows Excel form at .Do t he following t o download a report  t o your com puter:1I n the Syst em  Menu bar, click System Information >  Get Information.2On t he Get Information page, in t he Reports panel Type list, select  t he nam e of the report  that  you want  to download.3Click Download.4I n t he File Download window, click Save.
Get I nform at ion  Page 114 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20115I n t he Save As window, navigat e to where you want  the report file saved, and then click Save.The file is saved as specified.
Syst em  I nform at ionFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 115ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.6Go t o the directory where t he file was saved t o open t he file.NOTE: While Excel is often used to view this file, Excel uses characters such as hyphens and slashes to create formulas. If discrepancies are seen in this report, use a text editor to verify the report’s content.
Get Optics I nform ation  Page 116 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011GET OPTICS INFORMATIONThe Get Optics Information page allows you t o view inform ation on t he fiber.To access the Get Optics Information page, in t he Syst em  Menu bar, click System Information >  Get Optics Information.The Filter panel has t he following elem ent s:•View list —allows you t o select  a filt er to be applied t o the page•contains box—allows you t o ent er filt er crit eria•Filter button—click t o apply t he filt erThe Get Optics Information t able has the following elem ents:•Unit Type—whether the unit  is a Host or Rem ot e•Unit Name—user defined nam e of t he unit•SFP Number—syst em  assigned num ber ( from  1 t o 8) for t he Optical port s•SFP Name—user ent ered port nam e or UNKNOWN_SFPNAME, which indicates that a nam e has not  been entered.• Optics Type–LongRange—26 dB–IntermediateRange—18 dB) .
Syst em  I nform at ionFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 117ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.•Wavelength (nm)—num ber displayed is t he wavelengt h transm it t ed through this port :– Non- duplex and WDM configurat ions1550 nm  fwd1310 nm  rev– CWDM configurations can be one of eight  wavelengt hs:•Tx Power (dBm)—launch power level in dBm  of forward pat h signal. The m inim um  FWD launch power is - 2 dBm , and t he m axim um  is 3 dBm .•Rx Power (dBm)—Receive power level in dBm  of reverse pat h signal, which incorporates the launch power of t he Rem ot e Unit  SFP plus all optical losses ( insert ion losses, fiber cable loss, and so fort h) .•Remote Name—nam e of the Rem ot e connected t o t his Optics port .•Alarm Status—whet her an alarm  is active. I f an alarm  is act ive, there will be a Minor or Major link t hat  you click to open a dialog that  defines the act ive alarm , as described in “ Viewing Alarm  Det ails”  on page 45. The background color of the Alarm Status cell also indicat es t he alarm  level (see “ Alarm  Color Codes”  on page 44) .1470 nm 1550 nm1490 nm 1570 nm1510 nm 1590 nm1530 nm 1610 nm
Get Logs  Page 118 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011GET LOGSThe Get Logs page allows you to save com pressed t ar archive files of Prism  logs.This featur e is prim arily used by ADC personnel when t roubleshoot ing a syst em . However, you should know how t o creat e a log so you can em ail the log t o ADC if request ed t o do so.1To access the Get Logs page, in t he System  Menu bar, click System Information >  Get Logs.2Click Get Logs.3I n t he File Download dialog, click Save.
Syst em  I nform at ionFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 119ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.4I n t he Save As dialog, navigat e t o where you want  t o save the log file.Aft er a log has been creat ed, it  is list ed as an Available Log in t he Get Logs page.5I n Windows, navigat e t o where you saved the log zip file on your hard drive.6Double- click on t he t ar file to access the logs.
Get Logs  Page 120 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011I nt ent ionally Blank Page
FlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 121ADCP- 77- 177  • I ssue 1 • July 2011 © 2011 ADC Telecommunications, Inc.SYSTEM MANAGEMENTMoving or Reconfiguring Fibers .............................................................................................. 122Edit  t he Properties of All Unit s in t he System ........................................................................... 123Reset All Unit s t o Fact ory Default ........................................................................................... 124Backing Up a Syst em  Configurat ion ........................................................................................ 126Restoring a Backed Up System  Configuration ........................................................................... 128Perform  Syst em  Test ............................................................................................................ 131Schedule Syst em  Test .......................................................................................................... 135Schedule Syst em  Test s by Dat e and Tim e .......................................................................... 135Disable a Scheduled Syst em  Test ...................................................................................... 137Set  SNMP Trap Managers ...................................................................................................... 138Adding an SNMP Trap Manager ......................................................................................... 139Modifying an SNMP Trap Manager ..................................................................................... 141Delet ing an SNMP Trap Manager ....................................................................................... 142Set up SNMP  ....................................................................................................................... 144Activate Optional Features .................................................................................................... 145The EMS views and param et ers discussed in t his section affect  the entire Prism  syst em , as opposed t o affecting an individual unit  or m odule.Topics Page
Moving or Reconfiguring Fibers  Page 122 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011MOVING OR RECONFIGURING FIBERSI f you need t o m ove or reconfigure fibers during t roubleshoot ing, follow t he st eps below.1Move Host  SFPs and fibers to t heir new locations.2Do t he following if a previously filled SFP posit ion is now em pty:aThere will st ill be a GUI  represent at ion of a Rem ot e on t hat  SFP. To rem ove this ghost represent at ion, follow the st eps in “ Clear All Disconnect  Alarm s”  on page 184.bTo delete fiber and SFP alarm s at t ribut ed t o the abandoned SFP positions, follow t he st eps in “ Clear Current Alarm s”  on page 170.3 Com ple t e t his st ep only for m oved DARTs now  in a n alarm e d st ate. I f the configurat ion of a Rem ot e Unit  DART originally connect ed t o an SFP does not  m atch t he configurat ion of the DART m oved t o t he SFP, the new DART will have an alarm  st at e such as Module Missing Fault or DART Hardware Mismatch. I n this inst ance, follow the st eps in “ Clearing DART Configurat ions”  on page 161 to clear the configurat ion of t he DART in the alarm ed st at e.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 123ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.EDIT THE PROPERTIES OF ALL UNITS IN THE SYSTEMThe Edit Unit Properties page t hat  is accessible t hrough the Syst em  Menu bar allows you t o edit  basic inform ation and opt ionally provide not es for all t he unit s in the syst em  at one tim e.To access the Edit Unit Properties page, in t he Syst em  Menu bar, click System Configuration >  Edit Unit Properties.The Edit Unit Properties page has the following elem ent s, where each row in the Edit Unit Properties t able correspond t o the unit  identified in the Unit Id colum n.•Unit Id colum n—ident ifies t he unit  wit hin t he system ;  see “ Unit I dent ificat ion”  on page 43.•Unit Name colum n—provides a text  box t hat  allows you t o ent er a unique nam e for t he Host  and each connect ed Rem ot e. Each Unit Name m ust  st art  with an alphabet ical charact er, be between 5 and 40 charact ers (alphanum eric or underscore only) , and contain no spaces.•IP Address colum n—t he I P address of t he unitNOTE: An IP address of the type 169.254.x.y will only be communicable if the connected laptop also has a 169.254.x.y address. •Contact Alarms colum n—ident ifies act ive contact alarm s, if any. For inform ation on contact alarm s, see any of t he following:–“ Contact  Alarm s—Host Syst em  Card”  on page 201–“ Contact  Alarm s—Rem ot e Unit ”  on page 201•Notes colum n—provides a text  box t hat  allows you t o ent er notes specific to t he unit . You can ent er up t o 256 charact ers;  all keyboard charact ers can be used.
Reset  All Unit s t o Fact ory Default  Page 124 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011RESET ALL UNITS TO FACTORY DEFAULTThis procedure reset s t he Host  and all connected Rem ot e Unit s ( PRU or URU)  to their fact ory default settings.This procedure does not  clear com m anded Out of Service and Band Lockout  set tings ( see Table  on page 42) .1Docum ent all configurat ion dat a, as everything except  user I Ds and I P configurat ion will have to be re- ent ered. To record the current configuration:aFollow the procedures in “ Viewing t he All Report” on page 112 t o access the syst em  configurat ion reports.bFollow the procedures in “ Downloading a Report ”  on page 113 t o download the syst em  configurat ion reports to a hard drive.2I n t he Syst em  Tree, click on the Host  icon.3I n t he Unit Menu bar, click Unit Configuration >  Edit Properties, t o open t he Unit Configuration > Edit Properties page.4Click Reset all units to factory defaults.5I n t he confirm at ion dialog, click OK.The syst em  configuration is cleared, and you are logged out  of your current  EMS session.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 125ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.6Log back int o the EMS t o reconfigure t he system .NOTE: It may take a few minutes for the EMS to recognize the Host and connected remotes.
Backing Up a System  Configurat ion  Page 126 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011BACKING UP A SYSTEM CONFIGURATIONThe Backup page allows you t o backup t he syst em  configurat ion. A backup file size is t ypically less t han 1 MB, and a new backup overwrit es the pre- exist ing backup. You use the backup file t o restore t he configuration as described in “ Rest oring a Backed Up Syst em  Configurat ion”  on page 128.Do t he following t o backup a syst em  configurat ion:1I n t he Syst em  Menu bar, click System Configuration >  Backup.2Click Backup. I f the back up procedure fails, the following error m essage displays:  Failed to create Back Up. At  the end of a successful backup, a link t o t he downloaded file appears. 3To download the back-up file, click t he link that  appears, t he nam e for which is in the form at of HOSTNAME_<DATETIME>.tgz. Only one file will be available.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 127ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.4I n t he File Download window, click Save.5I n t he Save As window, navigat e to where you want t he backup file saved, and then click Save.
Rest oring a Backed Up System  Configur at ion  Page 128 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011RESTORING A BACKED UP SYSTEM CONFIGURATIONCAUTION! A System Restore can only occur if a previous system configuration has been backed up as described in “Backing Up a System Configuration” on page 126.CAUTION! A system restore requires that you log back into the system. Once you click the Restore button, the system will be unavailable for approximately two minutes. Perform this procedure during a maintenance window.NOTE: A System Restore can only be performed by a user logged in as admin user or by a user with Network Manager rights. A user assigned only Network User rights will not see the System Restore node in the Function System Tree.The System Restore page allows for a restorat ion of a backed up syst em  configurat ion, as follows:•The Restore funct ion assum es t hat  the sam e or com parable replacem ent hardware com ponents are in place as when t he Backup funct ion occurred. I f hardware com ponent changes have occurred, alarm s t hat point  to t he differences will arise.•I f a Rem ot e has been added ( that  is, was not  part  of t he original system  hardware setup) , then t he newly added Rem ot e will not  be restored since it  was not  present  during t he syst em  configurat ion backup.Do t he follow ing t o r est ore a sy st e m  back up: 1Make sure t here is sufficient disk space for the backed up syst em  configuration that  you want t o rest ore.2I n the Syst em  Menu bar, click System Configuration >  Restore.3Click t he Browse but t on next  to t he File box t o browse to the location of t he backup file.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 129ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.4I n t he Choose File window, click on t he back- up file to select it  (the backup filenam e is in the form at of HOSTNAME_<DATETIME>.tgz, and then click Open.5I n t he Restore page, wait  for t he file nam e and pat h t o display in t he File box and for t he ennoblem ent of t he Upload but ton, and then click Upload.6I n t he Restore page, wait  for t he file upload m essage t o display and for the ennoblem ent  of the Upload and Restore buttons, and t hen click Restore.
Rest oring a Backed Up System  Configur at ion  Page 130 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20117I n t he confirm at ion dialog, click OK. St atus m essages display t o not ify you if t he restorat ion failed or com plet ed successfully. Aft er a successful rest orat ion, you are logged out of t he syst em .8Log back in t o t he EMS to cont inue m anagem ent activit ies.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 131ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.PERFORM SYSTEM TESTSyst em  Test perform s an RF integrit y check of the syst em . Cert ain alarm s ( such as the RAU Antenna Disconnect alarm ) can only be set  or cleared by running Syst em  Test .CAUTION! Running System Test (System Configuration > Perform System Test) with un-terminated Host DARTs may cause a false RLM Upconvert Fault. Ensure that all Host DARTs are terminated before running System Test.CAUTION! System Test interrupts RF transmission; System Test should therefore only be run during a normal maintenance window.CAUTION! Do not make any software or hardware configuration changes during System Test, as changes made during the test will make the test results unreliable.1I n the Syst em  Menu bar, click System Configuration >  Perform System Test.NOTE: The table at the bottom of the Perform System Test page presents the results of the last System Test, if any, as shown above.
Perform  Syst em  Test  Page 132 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20112I n t he Bands list , select  t he passbands for which you want t o perform  Syst em  Test . Only configured passbands will be list ed in t he Bands list .3I n t he DART list , select  t he DART you want  t o perform  Syst em  Test. Only t hose DARTS that  are available will be list ed in t he DART list .CAUTION! Regardless if only 1 DART or all DARTs are selected for System Test, System Test temporarily shuts down the RF to all DARTs in the system.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 133ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.4Click Perform System Test. A System Test has started m essage displays.This m essage should be followed by one of t hese m essages. You m ay need to click Refresh to see these m essages.•System Test passed. •System Test failed. •System Test not available. •System Test passed – exceptions noted in log file. Aft er a few seconds, t he Last Test Results panel updates wit h a list  of m aj or and m inor alarm s wit h a corresponding t im est am p for when System  Test  was run.5( Opt ional)  Do the following t o download t he result s of System  Test  (to m ake the file available for later use, such as t roubleshoot ing) .aClick t he Click Here to Download link.bI n t he File Download dialog, click Save.
Perform  Syst em  Test  Page 134 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011cI n t he Save As dialog, navigat e t o where you want  to save t he file, and t hen click Save.The file is saved in Excel form at .
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 135ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.SCHEDULE SYSTEM TESTYou can schedule a Syst em  Test t o run on a specific dat e and tim e, as described in:•“ Schedule Syst em  Test s by Dat e and Tim e”  on page 135•“ Disable a Scheduled System  Test ”  on page 137Schedule System Tests by Date and TimeCAUTION! Running System Test (System Configuration > Perform System Test) with un-terminated Host DARTs may cause a false RLM Upconvert Fault. Ensure that all Host DARTs are terminated before running System Test.CAUTION! System Test interrupts RF transmission; System Test should therefore only be run during a normal maintenance window.CAUTION! Do not make any software or hardware configuration changes during System Test, as changes made during the test will make the test results unreliable.Do t he following t o schedule a single or recurring Syst em  Test:1I n the Syst em  Menu bar, click System Configuration >  Schedule System Test.2Select   Enable t o enable the scheduled Syst em  Test ( see also “ Disable a Scheduled System  Test ”  on page 137) .3I n t he Bands list , select  t he band( s)  that  you want t o test .4I n t he DART list , select  t he DART(s)  t hat  you want t o t est .
Schedule Syst em  Test  Page 136 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20115Click t he icon to t he right  of t he DATE box to schedule on which dat e t he Syst em  Test  will run. I f you enter t he date m anually, use the YYYY/MM/DD form at . For exam ple, to run a Syst em  Test  on 14 June 2011, enter:  2011/06/14.6I n t he Time box, ent er the tim e that  the Syst em  Test  is to run. Use the 24- hour tim eclock form at of HH:MM:SS.7( Opt ional)  Use the Recurrence radio but t ons to set up a recurring Syst em  Test . •To have the Syst em  Test recurrence int erval be counted by days, select  the Day(s) (1-30) radio but t on, and t hen in the corresponding box, ent er how m any days should pass between each occurrence of this Syst em  Test .•To have t he Syst em  Test  recurrence int erval be counted by weeks, select  the Week(s) (1-4) radio but t on, and t hen in t he corresponding box, ent er how m any weeks should pass bet ween each occurrence of this Syst em  Test .8Click Apply. NOTE: If you leave either the DATE or TIME parameter empty and then click Apply, Schedule System Test will not run. However, if you leave both the DATE and TIME parameters empty and then click Apply, the System Test starts immediately.The following exam ple has scheduled a Syst em  Test for 850 Classic passbands on 850 Classic DARTs inst alled in Host1 t o occur on 2 April 2011 at  1: 00 AM. This System  Test  will occur in one- week int ervals.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 137ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Disable a Scheduled System TestWhen you disable a scheduled Syst em  Test, t he Bands, DART, Date, and Time set ting rem ain, but the test will not  be run again unt il enabled.1I n the Syst em  Menu bar, click System Configuration >  Schedule System Test.2Deselect  Enable. 3Click Apply.
Set  SNMP Trap Managers  Page 138 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011SET SNMP TRAP MANAGERSThe Set SNMP Trap Managers page allows you t o add, delet e, and m odify SNMP Trap Managers. The Registered Trap Manager table, at  the top of the page, details any exist ing SNMP Trap Managers, where:•Select radio but t on—allows you t o select  an exist ing SNMP Trap Manager to m odify or delet e it .•IP Address—shows t he I P address of regist ered trap m anagers•Port—shows the port  num ber for regist ered t rap m anagers•Community—shows t he Com m unity password for regist ered trap m anagers•Version—shows t he trap version for regist ered t rap m anagersI f a Trap Manager has not been created, t he t able is em pt y:
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 139ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Adding an SNMP Trap Manager1I n the Syst em  Menu bar, click System Configuration >  Set SNMP Trap Managers.2I n t he Add New Trap Manager panel, do t he following:aI n t he IP Address box ent er the I P address of t he device t hat  you want t o add as a t rap receiver. The address m ust be in t he xxx.xxx.xxx.xxx form at.bI n t he Port box, ent er t he port on the device t hat  will receive the traps. The norm al and recom m ended SNMP Trap port is 162.cI n t he Community box, enter a password that will allow access t o the device. The Community password m ust be between 6 and 20 alphanum eric characters ( usually public or private) .dI n t he Version list , select  the trap version for the SNMP Trap Manager t hat  you are regist ering ( V1 or V2c) .
Set  SNMP Trap Managers  Page 140 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20113Click Add.The Registered Trap Managers table updat es wit h the new SNMP Trap Manager.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 141ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Modifying an SNMP Trap Manager1I n t he Syst em  Menu bar, click System Configuration >  Set SNMP Trap Managers. The Registered Trap Managers table list s exist ing SNMP Trap Managers.2I n t he Registered Trap Managers t able, select  t he trap m anager t hat  you want t o m odify.3I n t he Add New Trap Managerpanel, do any of t he following:•I n t he IP Address box ent er a new I P address. The address m ust be in t he xxx.xxx.xxx.xxx form at.•I n t he Port box, enter t he port  on t he device t hat  will receive t he traps. The norm al and recom m ended SNMP t rap port is 162.•I n t he Community box, enter a password t hat allows access to t he device ( usually public or privat e) . The Com m unit y password is lim it ed to 20 charact ers.•I n t he Version list , select  the trap version for the SNMP Trap Manager t hat  you are regist ering.4Click Modify. The Registered Trap Managers t able updat es wit h t he m odified SNMP Trap Manager.
Set  SNMP Trap Managers  Page 142 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Deleting an SNMP Trap Manager1I n t he Syst em  Menu bar, click System Configuration >  Set SNMP Trap Managers. The Registered Trap Managers table list s exist ing SNMP Trap Managers.2I n t he Registered Trap Managers t able, select  the trap m anager that  you want t o delet e.3Click Delete.4I n t he confirm at ion window, click OK.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 143ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.The delet ed SNMP Trap Manager is rem oved from  t he Registered Trap Managerstable and will no longer receive traps.
Set up SNMP  Page 144 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011SETUP SNMP 1To access t he Setup SNMP page, in t he Syst em  Menu bar, click System Configuration>  Setup SNMP.2I n t he SNMP V1 Agent Override panel, do the following.aI n t he Mode list , select  t he SNMP V1 Agent  Override m ode:• Enabled• DisabledbI n t he Address box, ent er the SNMP V1 Agent Override address. I f t he SNMP Agent  Override Mode is not Disabled, t he syst em  uses this address as t he source address in t he t raps.3I n t he SNMP Port Number box, ent er the SNMP port  num ber for sets and gets.4Click Apply to m odify the SNMP set t ings.
Syst em  Managem entFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 145ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.ACTIVATE OPTIONAL FEATURESThe Activate Optional Features page allows you t o act ivat e opt ional features available in t he system  t hat  are purchased aft er t he Host  Unit has been shipped.NOTE: Activation Codes are supplied by ADC Technical Assistance (see “Appendix C: Contacting ADC/TE Connectivity” on page 297).1To access the Activate Optional Features page, in t he Syst em  Menu bar, click System Configuration >  Activate Optional Features.2I n t he Activation Code box that  corresponds to t he feat ure t hat you want  to act ivat e, ent er t he act ivat ion code provided by ADC.3Click Activate. The following Information m essage displays.
Activat e Opt ional Features  Page 146 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011I nt ent ionally Blank Page
FlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 147ADCP- 77- 177  • I ssue 1 • July 2011 © 2011 ADC Telecommunications, Inc.MANAGING UNITSBasic Unit  Views .................................................................................................................. 148View Optical Port s ................................................................................................................ 149Viewing DARTs .................................................................................................................... 151Viewing Net work St atist ics .................................................................................................... 152Editing Unit  Properties .......................................................................................................... 153Configuring Opt ical Ports.......................................................................................................153Viewing the Status of t he Host  Unit ........................................................................................ 154Viewing t he St at us of a Rem ot e Unit ....................................................................................... 156Module St atus Table ....................................................................................................... 156DART St atus Table .................................................................................................... 157LNA St atus Table ...................................................................................................... 158LPA St at us Table....................................................................................................... 158PD Stat us Table ........................................................................................................ 159Opt ical Status Table ........................................................................................................ 159Rem ot e Stat us Table....................................................................................................... 160Rem ot e Unit  Capacity and Tem perat ure............................................................................. 160Clear ing DART Configurat ions ................................................................................................ 161Set  t he Capacit y for a New Rem ot e Unit  RSI  Board ................................................................... 162Using t he EMS GUI  to Change t he Rem ot e Unit  Capacit y ...................................................... 162Using Telnet or ssh to Change t he Rem ot e Unit  Capacit y...................................................... 163Rebooting a Unit .................................................................................................................. 164Resett ing an LPA.................................................................................................................. 165This sect ion describes the Prism  EMS param eters whose set tings affect t he individual unit s wit hin a Prism  syst em .Topics Page
Basic Unit  View s  Page 148 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011BASIC UNIT VIEWSWhen you click on a device icon in t he Syst em  Tree, t he following view opens in the EMS View Fram e, in which t here are three places where t he select ed device is ident ified. Not ice also the indicat ors for act ive alarm s. I n this inst ance the alarm  overlays on the Host  and Rem ot e Unit  icons indicat e that an alarm  is act ive on each device, and t he Alarm  Count er shows the count of act ive alarm s.The following graphic identifies the com ponents in a basic unit  view.Figure 22. Overview of Components in a Basic Unit ViewThe Unit view provides t he following inform ation:•Name—user- defined or system  nam e of the select ed unit .•Unit Type—t he type of device that  t he select ed unit is:–Host–PRU—Prism  Rem ot e Unit–URU—URH Rem ote Unit•Alarm—highest  level of alarm  occurring on the select ed unit . Not ice t hat  in t his exam ple, t he Alarm  indicat ors show t hat t here are four Minor alarm s act ive on this syst em . The Unit  view let s you know that  at  least one of t he alarm s is act ive on the Host . •Temperature—int ernal tem perat ure of t he selected unit.•Notes—text  box t hat  allows you t o ent er notes specific t o the select ed unit . You can enter up to 256 charact ers;  all keyboard characters can be used.Host icon withMinor alarm overlayRemote Unit icon withMajor alarm overlayUnit identifier(by Unit Name)Unit identifiers inSystem Tree(by Unit Name and Unit ID)Alarm Counter(system wide)Unit identifier(by Unit Name)
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 149ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.VIEW OPTICAL PORTSThe View Optical Ports page shows the current usage and alarm  st at us of the optical port s on a Host  or a PRU/ URU plus the current values of key operat ing param et ers. The Host and PRU/ URU chassis have eight  opt ical ports, but  the View Optical Ports page only shows act ive port s ( t hose physically connect ed t o a Host  or PRU/ URU) . Each port in t he page represent s one set  of forward and reverse pat hs bet ween a Host and Rem ot e.1I n t he Syst em  Tree, click on an icon for a Host  or Rem ot e Unit.2I n the Unit  Menu bar, click Unit Information >  View Optical Ports. The View Optical Ports table has the following com ponent s:•SFP Number—Syst em  assigned port num ber. •SFP Name—user ent ered port  nam e or UNKNOWN_SFPNAME, which indicat es that  no nam e has been ent ered. •In/Out—used for cascading, which is not support ed in this release. The Host  will therefore always be set as Out ( indicat es that  t he forward link for t he connect ed SFP is going away from  t he Host) and t he SFPs for all Rem ot e Unit s will always be set as In.• Optics Type–LongRange—26 dB–IntermediateRange—18 dB.
View  Opt ical Port s  Page 150 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011•Wavelength (nm)—wave length transm it t ed through t his port:– Non- duplex and WDM configurat ions:  1550 nm  fwd or 1310 nm  rev– CWDM configurations can be one of eight  wavelengths:•Tx Power (dBm)—launch power level in dBm  of forward path signal. The m inim um  FWD launch power is - 2 dBm , and the m axim um  is 3 dBm .•Rx Power (dBm)—receive power level in dBm  of reverse path signal, which incorporates the launch power of t he Rem ote Unit SFP plus all optical losses ( insert ion losses, fiber cable loss, and so fort h) .•Host Name/Remote Name—dependent  on t he unit  select ed in St ep 1 on page 149:– I f a Host  Unit  was select ed, t hen t he colum n is labeled Remote Name and the dat a in the colum n pert ains t o t he Rem ot e connected t o this Opt ical port  ident ified in SFP Number and SFP Name.– I f a Rem ot e Unit was select ed, t hen the colum n is labeled Host Name and t he dat a in t he colum n pert ains t o t he Host  (for selected PRU/ URU)  connect ed to t his Opt ical port identified in SFP Number and SFP Name.•Alarm Status—whet her an alarm  is act ive. I f an alarm  is act ive, t here will be a Minor or Major link t hat  you click t o open a dialog t hat  defines t he act ive alarm , as described in “Viewing Alarm  Det ails”  on page 45. The background color of the Alarm Status cell also indicat es t he alarm  level ( see “ Alarm  Color Codes”  on page 44) .1470 nm 1510 nm 1550 nm 1590 nm1490 nm 1530 nm 1570 nm 1610 nm
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 151ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.VIEWING DARTS1I n t he Syst em  Tree, click on t he icon of t he Host  or PRU/ URU for which you want t o view inform ation on it s DARTs.2I n t he Unit  Menu bar, click Unit Information >  View DARTs t o open t he View DARTspage. The table in t he View DARTs page provides t he following inform ation:•DART Number—identifies any installed DARTs by the slot  num ber in which it  is inst alled in the Host  or PRU/ URU chassis•DART Name—syst em  or user- assigned nam e;  default  is UNKNOWN_DARTNAME.•Band Type—which DART m odel is installed, and t he band t ype that  it  is providing•Passband—t ype of passband •Alarm Status—whet her an alarm  is active. I f an alarm  is act ive, t here will be a  Minor or Major link t hat  you click t o open a dialog that defines t he act ive alarm , as described in “ Viewing Alarm  Details”  on page 45. The background color of t he Alarm Status cell also indicat es t he alarm  level ( see “ Alarm  Color Codes”  on page 44) .
View ing Network St at ist ics  Page 152 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011VIEWING NETWORK STATISTICS1I n t he Syst em  Tree, click on an icon for a Host  or Rem ot e Unit .2I n t he Unit Menu bar, click Unit Information >  View Network Statistics t o open t he View Network Statistics page.The View Network Statistics table has the following com ponents:•Port—I dent ifies t he port s in the net work. •Rx Bytes—Receive byt e count er t hat  increm ents by t he byt e count of fram es received, including t hose in bad packet s, excluding pream ble and SFD but  including FCS bytes.•Rx Packets—Receive packet count er that  increm ent s for each fram e received packet  ( including bad packet s, all unicast , broadcast, and m ult icast  packets) .•RX FCS Errors—Receive FCS error count er that  increm ents for each fram e received that  has an int egral 64 t o 1518 lengt h and contains a fram e check sequence error.•Rx Broadcast Pkts—Receive broadcast packet count er t hat increm ents for each broadcast  good fram e of lengt hs 64 to 1518 ( non VLAN)  or 1522 ( VLAN) , excluding m ult icast  fram es. Does not  include range/ length errors.•Rx Multicast Pkts—Receive m ult icast packet  counter t hat  increm ents for each m ult icast  good fram e of lengt hs 64 to 1518 ( non VLAN) or 1522 ( VLAN) , excluding broadcast  fram es. This count  does not  include range/ lengt h errors.•Rx Fragmented Frames—Receive fragm ent s counter t hat  increm ent s for each fram e received that  cont ains an invalid FCS and is less than 64 byt es. This includes int egral and non-int egral lengt hs.•Rx Jabber Frames—Receive jabber count er t hat  increm ents for fram es received that  exceed 1518 ( non VLAN) or 1522 ( VLAN)  bytes and cont ain an invalid FCS. This includes alignm ent errors.
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 153ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.•Tx Byte Counter—Transm it  byte count er t hat  increm ents by t he num ber of byt es that  were put on t he wire including fragm ents of fram es t hat  were involved wit h collisions. This count does not  include pream ble/ SFD or j am  bytes. This counter does not  count if t he fram e is t runcat ed.•Tx Pkt Counter—Transm it  packet counter that  increm ent s for each t ransm it t ed packet  ( including bad packets, excessive deferred packets, excessive collision packets, lat e collision packet s, all unicast , broadcast, and m ult icast  packet s).•Tx Broadcast Pkts—Transm it  broadcast packet counter t hat  increm ent s for each broadcast  fram e t ransm it t ed ( excluding m ult icast  fram es) .•Tx Multicast Pkts—Transm it  m ult icast  packet count er that  increm ents for each m ult icast  valid fram e transm it t ed ( excluding broadcast fram es) .•Reset Counter but ton—click t o clear t he st at istics in the Network Statistics page.EDITING UNIT PROPERTIESUnit propert ies are set  during init ial set up, but  can be changed at  any t im e. See one of t he following:•“ Configure Basic Host  Unit  Propert ies”  on page 64•“ Label t he PRU/ URU”  on page 66.CONFIGURING OPTICAL PORTSOpt ical port  configurations are set during init ial set up, but can be changed at  any tim e. See one of t he following:•See “ Label the Host  Opt ical Port s”  on page 67.•See “ Label PRU/ URU Opt ical Ports”  on page 70.
View ing the St at us of the Host  Unit  Page 154 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011VIEWING THE STATUS OF THE HOST UNIT1I n t he Syst em  Tree, click on the Host  icon.2I n the Unit  Menu bar, click Unit Information >  View Status.The  Unit Information > View Status page provides the following inform ation for t he select ed Host . The background of each t able cell is color coded t o t he level of the alarm ;  see “ Viewing Param eters and Alarm s”  on page 44. For further inform ation on t hese fault s and alarm s, see “ Troubleshoot ing Alarm s”  on page 185.•Module Status t able—provides st atus inform ation for inst alled DARTs, where colum ns 1 through 8 correspond t o t he slot  in which t he DART resides ( Colum n 1 =  Slot  1, and so forth) . I f a DART colum n has no background color, a DART is not installed in that  slot .–DART Fault—Sum m ary of DART Downconverter 1 Synt hesizer Unlocked, Downconverter 2 Synt hesizer Unlocked, Upconvert er Synthesizer Unlocked, DC Supply Fault alarm s, and DART FPGA stat us.–DART Over Drive Fault—Red indicates t hat t he RF signal received from  t he BTS/ BDA is t oo st rong. Fault  t hreshold is + 19 dBm .–DART Under Drive Fault—DART forward RF input  signal below the norm al operating lim it . Fault  t hreshold is + 5 -  Fwd Gain -  20–Module Missing Fault—One of t he Host  pluggable m odules is m issing ( DART/ SFP). –DART Hardware Mismatch—Host  DART does not  support  the select ed passband. Fault  occurs when a Host DART is replaced wit h another DART of t he incorrect t ype.•Optical Status table—shows t he current usage and alarm  st at us of the optical port s on the Host  plus t he current values of som e key operat ing param et ers.
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 155ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.The Host  has eight optical port s, but t he Optical Status table only shows act ive port s (physically connect ed t o a Rem ot e) . Each port  in t he table (where SFP 1 is colum n 1, SFP 2 is colum n 2, and so forth)  represent s one set  of forwar d and reverse paths between a Host and Rem ot e. Physically, t his m ay have been accom plished wit h a dual-connect or through that  port . Each physical port cont ains an SFP t ransceiver wit h t wo connectors.The Optical Status t able only shows t he Receive power level from  t he Rem ot e Unit  ( REV pat h) . To see the Receive power level in the FWD pat h ( from  t he Host t o the Rem ot e), you m ust  open the Unit Information > View Status page for t he desired Rem ot e as described in “ Viewing t he St atus of a Rem ot e Unit ”  on page 156.–Optical RX High BER—High bit error rat e ( BER) detected by fiber opt ic receiver. Fault  threshold is 0.00001. Threshold cannot be changed.–Optical RX No Light—No signal det ect ed by opt ical receiver. –Optical Transmitter Fault—SFP opt ical t ransm itter failed.–Optical Over Drive—SFP optical receive input  power above specification. The fault t hreshold cannot  be changed, and is1 dBm for I R -9 dBm for LR. –Optical Under Drive—SFP optical receive input  power below specificat ion. The fault t hreshold cannot  be changed, and is-18 dBm for I R -27 dBm for LR. –Module Missing Fault—One of t he Host SFPs is m issing.•Host Status table—shows the current overall stat us of t he Host .–Host Major Contact Alarm Output Active—Maj or Contact  Alarm  Output active.–Host Minor Contact Alarm Output Active—Minor Cont act Alarm  Output active.–Remote Major Contact Alarm Output Active—Red indicat es NO/ NC m aj or alarm  cont act s are in an alarm  posit ion. These connect ions are typically wired t o a local alarm  alert system . This st atus indicat or is red when a m aj or alarm  is present  on any Rem ot e connected t o the Host . –Remote Minor Contact Alarm Output Active—Yellow indicates that  NO/ NC m inor alarm  contact s are in an alarm  position. These connections are typically wired t o a local alarm  alert  system . This st atus indicat or is yellow when a m inor alarm  is present on any Rem ot e connected t o Host. –SeRF Fault—st ate of t he SeRF. Red indicat es t hat  eit her t he SeRF clock source is unacceptable or t he SeRF card FPGA is not  program m ed.–Fan Fault—st at e of t he Host chassis fan. Red indicat es t hat  the Host  chassis fan is spinning t oo slowly.–Temperature High—Red indicat es t hat t he current t em perat ure of t he Host int erior is above it s operat ing lim it s. Fault  t hreshold is 62° C. –Temperature Low—Yellow indicates that  t he current t em perat ure of the Host int erior is below its operat ing lim it s. Fault  t hreshold is 0° C. •Temperature—Gives t he current t em perature of the Host  chassis int erior in degrees Centigrade, as det ect ed by t he Host .
View ing t he St at us of a Rem ot e Unit  Page 156 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011VIEWING THE STATUS OF A REMOTE UNITFor furt her inform ation on t he faults listed in t he View Stat us page for Rem ot e Units, see “ Troubleshoot ing Alarm s”  on page 185.1I n t he Syst em  Tree, click on t he icon of the PRU/ URU for which you want  t o view it s st at us.2I n the Unit  Menu bar, click Unit Information >  View Status.The  Unit Information > View Status page provides the following inform ation for t he select ed Rem ot e Unit . The background of each t able cell is color coded t o the level of t he alarm ;  see “ Viewing Param eters and Alarm s”  on page 44. For m ore inform at ion on the fault s and alarm s, see “Troubleshoot ing Alarm s”  on page 185.Module Status TableThe  Module Status t able provides st at us inform at ion for PRU/ URU m odules where colum ns 1 t hrough 8 correspond t o the slot  in which a DART resides ( see “ RF Module Capabilit ies and GUI  Represent at ion”  on page 21) . The following sect ions describe the different  sections wit hin t he Module Status t able.
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 157ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.DART Status TableThe DART Status t able presents stat us of the DARTs in a Rem ot e Unit . There can be bet ween 1 and 8 DARTs inst alled in a Rem ot e Unit. I f a DART colum n has no background color, a DART is not inst alled in that  slot , as shown below.The DART Status t able has t he following elem ents.•DART Fault—Sum m ary of DART Downconverter 1 Synt hesizer Unlocked, Downconverter 2 Synt hesizer Unlocked, Upconvert er Synthesizer Unlocked, DC Supply Fault alarm s, and DART FPGA stat us.•DART DC Supply Fault—DART Module DC supply voltages out side specificat ion.•DART Hardware Mismatch—Host  DART does not  support t he select ed passband. Fault  occurs when a Host DART is replaced wit h another DART of the incorrect  type.•DART Temperature High—DART tem perat ure above operating lim it . Threshold is 85° C.•Delay Out Of Range—PRU/ URU delay set t ings out side t he valid range.•DART Temperature Low—DART t em perature below operating lim it . Threshold is - 40° C.•Module Missing Fault—DART m odule is m issing.
View ing t he St at us of a Rem ot e Unit  Page 158 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011LNA Status TableThe  LNA Status table present s st at us inform ation for t he Low Noise Am plifiers in a Rem ot e Unit . There can be bet ween 1 and 8 LNAs inst alled in a Prism  Rem ot e Unit .•LNA Power Fault—PRU/ URU Low Noise Am plifier Power fault.•Module Missing Fault—LNA m odule is m issing.LPA Status TableThe LPA Status t able presents stat us inform ation for t he Linear Power Am plifiers in a Rem ote Unit. There can be bet ween 1 and 4 LPAs inst alled in a Prism  Rem ot e Unit .•LPA Disabled—PRU/ URU Linear Power Am plifier ( LPA)  disabled due to an int ernally det ect ed problem .  (VSWR, DC, Loop Fault , Low Power, or Tem perat ure High alarm ) .•LPA VSWR Fault—PRU/ URU Linear Power Am plifier ( LPA)  VSWR fault .•LPA DC Fault—PRU/ URU Linear Power Am plifier ( LPA) DC fault .•LPA Loop Fault—PRU/ URU Linear Power  Am plifier ( LPA)  Loop fault .•LPA Over Power—PRU/ URU Linear Power Am plifier ( LPA)  out put  power level above operating lim it .•LPA Low Power Fault—I nt ernal Linear Power Am plifier ( LPA)  Low Power fault . Gain of one or m ore internal am plifiers out side of specificat ion) .•LPA Missing—LPA m odule is m issing.•LPA Over Temperature—PRU/ URU LPA above operat ing lim it .
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 159ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.PD Status TableThe PD Status t able presents stat us inform ation for t he Power Det ect or in a Rem ot e Unit. There can be between 1 and 4 PDs inst alled in a Prism  Rem ot e Unit .•System VSWR Fault—PRU/ URU VSWR m easurem ent above specificat ion.•RF Power Low—PRU/ URU RF Out put  Power below m inim um  threshold.•Module Missing Fault—Power Det ect or m odule is m issing.•Duplexer Mismatch—Configured frequency range not  support ed by Duplexer.Optical Status TableThe Optical Status t able provides st atus inform ation for SFPs inst alled in a Rem ot e Unit ( PRU/ URU) .There can be bet ween 1 and 8 SFPs inst alled in a Rem ot e Unit . I f a colum n has no background color, an SFP is not  inst alled in that  slot . •Optical RX High BER—High bit  error rat e ( BER) det ect ed by fiber optic receiver. Threshold is 0.00001.•Optical RX No Light—No signal det ect ed by opt ical receiver.•Optical Transmitter Fault—SFP opt ical t ransm itter failed.•Optical Over Drive—SFP opt ical receive input  power above specification. Thresholds are as follows:–1 dBm for I R –-9 dBm for LR. •Optical Under Drive—SFP optical receive input power below specification. Thresholds are as follows:–-18 dBm for I R–-27 dBm for LR.•Module Missing Fault—SFP m odule is m issing.
View ing t he St at us of a Rem ot e Unit  Page 160 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Remote Status Table The  Remote Status t able provides general st at us inform at ion for a Rem ot e Unit  ( PRU/ URU) . •Host Lost—Host  is not  com m unicating wit h PRU/ URU.•AC Power Supply Fault—Power supply is in a failed st ate, or the AC power is below t he m inim um  required voltage. •Temperature High—Tem perat ure above operating lim it . Threshold is 95° C.•Temperature Low—Tem perat ure below operating lim it . Threshold is Minus 40° C.•Contact Alarm Input 1 Active—Host  Contact Alarm  I nput # 1 active.•Fan Under Speed—Fans operating below expect ed RPM.•Contact Alarm Input 2 Active—Host  Contact Alarm  I nput # 2 active.•Fan Over Speed—Fans operating above expect ed RPM.•Door Open—Door open on PRU.•SeRF Fault—Sum m ary of SeRF Synt hesizer Unlocked alarm  and SeRF FPGA st at us.•Software Version Mismatch Fault—Soft ware version on the Host  and Rem ot e Units do not  m atch.Remote Unit Capacity and TemperatureThe  Unit Information > View Status page for Rem ot e Unit s also provides unit capacit y and t em perat ure inform ation for the select ed Rem ot e Unit ( PRU/ URU) . •Capacity—the num ber of RF groups available to t he Rem ot e Unit .•Temperature—The int ernal Tem perat ure of the select ed unit .
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 161ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.CLEARING DART CONFIGURATIONSThis procedure does the following:  •resets t he gain•resets t he DART nam e•clears all links•clears the passband•clears all associat ed alarm s1I n t he Syst em  Tree, click on an icon for a Host  or Rem ot e Unit.2I n t he Unit  Menu bar, click Unit Configuration >  Clear DART Configuration, t o open the Clear DART Configuration page.3I n t he Select colum n, select  t he DART(s)  for which you want t o clear configurat ion.4Click Clear Configuration.5I n t he confirm at ion window, click OK.
Set  t he Capacit y for  a New Rem ot e Unit  RSI  Board  Page 162 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011I f t he DART has been rem oved from  t he Host or PRU/ URU chassis, then t he ent ire DART ent ry disappears. I f the DART is st ill present  in t he Host  or PRU/ URU chassis, t hen the DART Name and Passband is reset t o default.SET THE CAPACITY FOR A NEW REMOTE UNIT RSI BOARDThe Capacity set t ing in the Edit Properties page pert ains to t he PRU/ URU Rem ot e SeRF I nt erface ( RSI ) board and t he num ber of RF groups available t o the Rem ot e Unit . This param et er is set during m anufacturing and should be changed only when t he RSI  board has been replaced.Using the EMS GUI to Change the Remote Unit CapacityThe Capacity setting can be changed by logging onto the EMS t hrough t he Rem ot e Craft port .1Open t he unit  and connect your laptop t o t he Craft port on t he SeRF.2Login to t he EMS, using t he following param eters:•I P address is 192.168.0.1 •User Nam e is operator •Password is operator
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 163ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.3I n t he Syst em  Tree, click the icon of the PRU/ URU whose propert ies you want  to change.4I n t he Unit Menu bar, click Unit Configuration >  Edit Properties, t o open the Unit Configuration > Edit Properties page for t he select ed PRU.5I n t he Capacity list , set  the Capacity of t he new RSI  board:•For all RSI  boards inst alled in a URH, Capacity should always be set t o 3.•For an RSI  board inst alled in a PRU, Capacity can be 1, 2, 3, or 4 and indicat es the num ber of RF Modules inst alled in the PRU.6Click Apply.Using Telnet or ssh to Change the Remote Unit CapacityAlt ernat ely, t he capacit y can be changed using Telnet  or ssh. 1Access the Edit Unit  Propert ies page to det erm ine t he I P address for the Host  and Rem ote Unit(s) . I n the Syst em  Menu bar, click System Configuration > Edit Unit Properties. Each row in t he Edit Unit Properties table correspond t o the unit  ident ified in the Unit Id colum n. Use the IP Address colum n to det erm ine t he I P address for each unit .2Login to t he Host  using telnet or ssh.3From  t he Host , login t o the Rem ot e Unit  using t he following com m and,where Nis t he Rem ot e Unit I D ( 1 -  8):  sshremote N 4Once logged into t he Rem ot e Unit , execut e t he following com m and, where X is the capacity ( 1-4) :  /usr/local/fwu/bin/EEPROMWriteForCapacity.sh X
Reboot ing a Unit  Page 164 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011REBOOTING A UNITCAUTION! The system configuration is stored on the Host. Rebooting the Host therefore results in a loss of RF for the Host and connected Remote Units until the Host comes back up. Depending on the system configuration, it can take 5 to 20 minutes before management communication is restored. CAUTION! Host configuration persists across a Reboot. However, the current EMS session will close and you will need to log back in to the EMS after the Host reboot has completed.CAUTION! Rebooting a Remote Unit causes Loss of Service and should not be used unless other troubleshooting processes have been followed and did not fix the issue being experienced at the PRU/URU. 1I n the Syst em  Tree, click on t he icon of the unit t hat  you want t o reboot.2I n t he Unit Menu bar, click Unit Configuration >  Reboot, t o open the Unit Configuration > Reboot page.3Click Reboot.•Once the reboot  st art s, a process m essage displays.•Aft er t he reboot  has com plet ed, a Unit has been rebooted m essage displays.•Aft er the Host  reboots, the EMS login window opens.
Managing Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 165ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.RESETTING AN LPACAUTION! Once an LPA Reset is started, Loss of Service occurs. It takes approximately 10 to 20 seconds before the LPA signal recovers. The GUI RF power reading will take longer depending on the number of Remotes equipped—for a fully loaded Prism system with 8 Remotes the power reading could take several minutes to update.NOTE: Only a user logged in under the admin or a Network Manager account can change Prism system settings through the EMS.You use the LPA Reset but t on to bring an LPA back int o service ( restart) t hat  st opped because of a m aj or LPA alarm . I n a dual-LPA syst em , reset t ing the LPA applies t o bot h LPAs at t he sam e tim e.1To access the Configure Remote Forward Gain page, in t he Syst em  Menu bar, click System Configuration >  Configure Remote Forward Gain.2I n t he Remote Id list , select  t he Rem ote Unit  whose LPA you need to reset .3I n t he Remote DART list , select  t he DART whose LPA you need t o reset .4Click t he LPA Reset but ton.5I n the LPA Reset  caution dialog, click OK.
Reset t ing an LPA  Page 166 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011I nt ent ionally Blank Page
FlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 167ADCP- 77- 177  • I ssue 1 • July 2011 © 2011 ADC Telecommunications, Inc.ALARMSView Current  Alarm s.............................................................................................................168Clear  Current  Alarm s ............................................................................................................170View Alarm  Hist ory ............................................................................................................... 170Clear ing Alar m  Hist ory ..........................................................................................................172Filt ering the Alarm  History.....................................................................................................172Manage Alarm s.................................................................................................................... 174Enable and Disable Host  and Rem ot e Unit  Alarm s ............................................................... 178Set  RF Power Low Threshold ............................................................................................ 180Ant enna Disconnect  Alarm ............................................................................................... 181Manage Cont act  Alarm s ........................................................................................................ 182Acknowledge All Alarm s ........................................................................................................ 183Clear  All Disconnect  Alarm s ................................................................................................... 184Troubleshooting Alarm s ........................................................................................................ 185Maj or Alarm s—Host  Unit .................................................................................................. 185Maj or Alarm s—Host  Unit  DARTs........................................................................................ 185Maj or Alarm s—Host  SeRF Modules .................................................................................... 187Maj or Alarm s—Host  Unit  SFPs .......................................................................................... 188Maj or Alarm s—Rem ot e Unit s ............................................................................................ 189Maj or Alarm s—PRU/ URU DARTs........................................................................................ 189Maj or Alarm s—PRU/ URU SeRF Modules.............................................................................. 191Maj or Alarm s—PRU/ URU SFPs .......................................................................................... 193Maj or Alarm s—PRU or URU Duplexer ................................................................................. 194Maj or Alarm s—PRU or URU LNA........................................................................................ 194Maj or Alarm s—PRU or URU LPA ........................................................................................ 195Maj or Alarm s—PRU or URU Power Det ect or ........................................................................ 196Minor Alarm s—Host  Unit  DARTs ........................................................................................ 197Minor Alarm s—Host  Unit  SeRF Module ............................................................................... 197Minor Alarm s—Host  Unit  SFPs .......................................................................................... 198Minor Alarm s—PRU/ URU DARTs........................................................................................ 198Minor Alarm s—PRU/ URU SeRF Modules.............................................................................. 199Minor Alarm s—PRU/ URU SFPs .......................................................................................... 200Minor Alarm s—PRU or URU LPAs ....................................................................................... 200Cont act  Alarm s—Host Syst em  Card ................................................................................... 201Cont act  Alarm s—Rem ot e Unit .......................................................................................... 201This sect ion describes how t o m anage and underst and t he alarm s that are report ed by t he EMS. This sect ion also provides corresponding Trap nam es.Topics Page
View  Current  Alar m s  Page 168 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011VIEW CURRENT ALARMSTo access the View Current Alarms page, in t he System  Menu bar, click Alarms >  View Current Alarms. ( For inform ation on the alarm  color codes, see “ Alarm  Color Codes”  on page 44.)The View Current Alarms t able provides the following inform at ion:•Severity—whet her t he alarm  is classified as Maj or or Minor.•Ack’d—whether the alarm  has been acknowledged, as indicat ed by a checkm ark.•Alarm Code—system -assigned alarm  code. •Alarm Name—descriptive nam e of alarm .•Timestamp—dat e and tim e when the alarm  occurred (YYYY:MM:DD:HH:MM:SS)•Unit Id—ident ifies t he unit  wit hin the syst em  t hat  raised t he alarm ;  see “ Unit  I dent ification”  on page 43.•Unit Type—what  t he unit is, such as Host  or Rem ot e•Unit Name—nam e assigned t o the unit•Module—type of m odule that is experiencing t he alarm  ( SeRF, DART, LPA, LNA, Power Det ect or, SFP)•Module Name—user- assigned nam e for the m odule. •RF Band—type of passband provided by the DART.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 169ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.•Extended Info—link t hat  once clicked opens anot her web page, which provides furt her inform ation on t he alarm , including troubleshooting inform at ion, as shown in t he following graphic.–Description—text  description of alarm–Remedy—what  you can do t o correct  t he alarm  st at e–Threshold—value t hat  once surpassed generat es an alarm–Notes—user- defined notes, if any, for the unit .
Clear Current Alarm s  Page 170 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011CLEAR CURRENT ALARMS1To access the View Current Alarms page, in the Syst em  Menu bar, click Alarms >  View Current Alarms.2I n t he View Current Alarms page, click Clear Alarms.3I n t he confirm at ion window, click OK.All current  alarm s, wit h t he except ion of persist ent  alarm s, are cleared from  the View Current Alarms t able.VIEW ALARM HISTORYTo access the View Alarm History page, in t he System  Menu bar, click Alarms >  ViewAlarm History. ( For inform ation on t he alarm  color codes, see “ Alarm  Color Codes”  on page 44.)
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 171ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.The View Alarm History table provides the following inform ation:•Severity—whet her t he alarm  is classified as Major or Minor.•Ack’d—whet her t he alarm  has been acknowledged, as indicated by a checkm ark.•Alarm Code—system -assigned alarm  code. •Alarm Name—descriptive nam e of alarm .•Timestamp—dat e and t im e when the alarm  occurred (YYYY:MM:DD:HH:MM:SS)•Unit Id—ident ifies t he unit  wit hin the syst em  t hat  raised t he alarm ;  see “ Unit  I dent ification”  on page 43.•Unit Type—what  t he unit is, such as Host  or Rem ot e•Unit Name—nam e assigned t o the unit•Module—type of m odule that is experiencing t he alarm  ( SeRF, DART, LPA, LNA, Power Det ect or, SFP)•Module Name—user- assigned nam e for the m odule. •RF Band—type of passband provided by the DART.•First, Previous, Last but tons—if t he View Alarm History t able is longer t han what  can fit  on a single web page, First, Previous, Last but tons are included:–First—j um ps the display t o the first  page of alarm s–Previous—jum ps t he display to t he page of alarm s that  you viewed im m ediat ely prior to t he current page–Last—j um ps t he display t o the last  page of alarm s•Clear History but t on—see “ Clearing Alarm  Hist ory” on page 172.
Clearing Alarm  History  Page 172 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011CLEARING ALARM HISTORY1To access the View Alarm History page, in the Syst em  Menu bar, click Alarms >  View Alarm History. 2Click Clear History.3I n t he confirm at ion window, click OK.The View Alarm History page is cleared.FILTERING THE ALARM HISTORYThe View Alarm History page allows you t o filt er, or  select, which alarm  hist ories you want t o page.1To access the View Alarm History page, in the Syst em  Menu bar, click Alarms >  View Alarm History. 2Do t he following in t he Filter panel:aI n t he View list , select  how you want  to filt er the alarm s:•None—all alarm s display•Unit Name—filt er by the user- assigned nam e of a unit•Host Number—filt er by t he syst em -assigned num ber for the Host•Remote Number—filter by t he system -assigned num ber for a Rem ote•Event Name—filter by an event  ( alarm  or incident) nam e.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 173ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.bI n t he contains box, ent er t he crit eria by which you want  t o filt er t he alarm  hist ory list .cClick Filter.The View Alarm History page refreshes, and now lists only t hose alarm s that  m eet the specified filter crit eria. I n t his exam ple, only t hose event s wit h t he word “ DART”  in them  display.
Manage Alarm s  Page 174 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20113To rem ove the filt er:aI n t he View list , select None.bDelet e any text  from  t he contains box.cClick Filter.MANAGE ALARMSTo access the Manage Alarms page, in the Syst em  Menu bar, click Alarms >  Manage Alarms. •For an exam ple of a Manage Alarms page for a Host  Unit , see Figure 23 on page 175 and Figur e 24 on page 176.•For an exam ple of a Manage Alarms page for a Rem ot e Unit , see Figure 25  on page 177 and Figure 26 on page 178.The Manage Alarms page has t he following elem ent s:•Select m enu—has t he following im plem entat ions:–Global—displays alarm s for t he Host  and all connect ed Rem ot e Unit s. Please not e, however, that  this view does not reflect t he current  st at us of alarm  enable/ disable condit ions—it is designed t o show you at  a glance those alarm s that  can be m anaged. To effect a change in the m anagem ent of an alarm  and t o see the current st ate of an alarm , select a specific unit .–Unit name—each unit  in the syst em  is list ed by nam e, which allows you t o select  for which unit  you want t o m anage alarm s. •Antenna Disconnect Severity m enu—see “ Antenna Disconnect Alarm ”  on page 181.•Unit field—what t ype of unit  t he alarm  pert ains t o:–Host –Remote •Module field—which m odule t he alarm  pertains to:–DART—can be up to eight DARTs listed–LNA—can be up t o t wo LNAs list ed– Power Detector –SFP—can be up t o eight  SFPs list ed –SeRF •Alarm Name field—identifies the alarm  by nam e;  see Table 23 on page 178. NOTE: For definitions of the alarms listed above, see “Troubleshooting Alarms” on page 185.•Enabled select ion box—select  to enable alarm  reporting for t he corresponding alarm .•Threshold Value field—value that once surpassed generat es the specified alarm ;  see Table 23 on page 178.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 175ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Figure 23. Example of Manage Alarms Page—Host Unit Part 1
Manage Alarm s  Page 176 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Figure 24. Example of Manage Alarms Page—Host Unit Part 2
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 177ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Figure 25. Example of Manage Alarms Page—Remote Unit Part 1
Manage Alarm s  Page 178 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Figure 26. Example of Manage Alarms Page—Remote Unit Part 2Enable and Disable Host and Remote Unit AlarmsThe  Manage Alarms page allows you t o enable and disable alarm  reporting for t he alarm s list ed in Table 23 on page 178.Table 23. Alarms That Can Be Enabled/Disabled  Unit Module Alarm Alarm ThresholdRemote RDI AC Power Supply 1 FaultRemote RDI AC Power Supply 2 FaultRemote RDI AC Power Supply 3 FaultRemote RDI AC Power Supply 4 FaultRemote PRU/URU AC Power Supply Fault
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 179ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Host DART DART ALC Limiting +19 - Fwd Gain dBmHost DART DART DC Supply FaultRemote DART DART DC Supply FaultHost DART DART Over Drive +19 dBmRemote DART DART Temperature High 85 Deg CRemote DART DART Temperature Low minus 40 deg CHost DART DART Under Drive +5 - Fwd Gain - 20 dBmRemote SeRF Door OpenRemote DART Downconvert FaultRemote DART DART DC Supply FaultRemote SFP Excess ConnectionsHost DART FLM Downconvert FaultRemote DART FWD Cal Tone FaultRemote SFP Invalid Device ConnectionRemote LNA LNA Power FaultHost SFP Optical Over Drive 1 dBm(IR)/-9dBm(LR)Remote SFP Optical Over Drive 1 dBm(IR)/-9dBm(LR)Host SFP Optical RX High BER 0.00001Remote SFP Optical RX High BER 0.00001Host SFP Optical RX No LightRemote SFP Optical RX No LightHost SFP Optical Under Drive -18 (IR) dBm/-27 dBm (LR)Remote SFP Optical Under Drive -18 dBm (IR)/ -27 dBm (LR)Remote DART REV Test Tone LowRemote PD RF Power Low  0 dBm*Host DART RLM Upconvert Fault Host DART RLM Upconvert Indeterminate Remote SeRF Software Version Mismatch Fault Remote PD System VSWR Fault  3:1Host SeRF Temperature High  62 Deg CRemote SeRF Temperature High  95 Deg CPRU/URU SeRF Temperature High  62 Deg CHost SeRF Temperature Low  0 Deg CRemote SeRF Temperature Low Minus 40 Deg CPRU/URU SeRF Temperature Low 0 Deg CRemote LPA Under PowerRemote DART Upconvert FaultRemote DART Upconvert IndeterminateRemote DART Uplink Inactivity Fault 10 dB above the noise floor.* You can manually set the threshold for RF Power Low; see “Set RF Power Low Threshold” on page 180Table 23.  Alarms That Can Be Enabled/Disabled  (Cont.)Unit Module Alarm Alarm Threshold
Manage Alarm s  Page 180 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Do t he following t o enable/ disable alarm  report ing:1To access the Manage Alarms page, in the Syst em  Menu bar, click Alarms >  Manage Alarms.2I n t he Select list , select  the Rem ot e Unit  for which you want t o change the threshold of the RF Power Low alarm .3I n t he Threshold Value box for t he RF Power Low alarm , ent er the new t hreshold, which m ust  be bet ween 0 dB -  40 dB.4Click Apply.Set RF Power Low ThresholdThe following rules apply to set t ing alarm  t hresholds:•Only the t hreshold for the RF Power Low alarm  can be changed.•Only users wit h Network Manager or Adm in privileges can perform  t his procedure.•Alarm  t hresholds cannot  be set  t hrough SNMP MI Bs.•I f you perform  a Reset to Factory Defaults, t he alarm  t hreshold values are reset;  you will need t o be reconfigure the alarm  t hreshold values, as necessary. •Alarm  t hreshold values are configured by unit —t hey cannot  be set  globally for all units in t he syst em .Do t he following t o set t he RF Power Low alarm  t hreshold:1To access the Manage Alarms page, in the Syst em  Menu bar, click Alarms >  Manage Alarms.2I n t he Select list , select  the Rem ot e Unit  for which you want t o change the threshold of the RF Power Low alarm .3I n t he Threshold Value box for t he RF Power Low alarm , ent er the new t hreshold, which m ust  be bet ween 0 dB -  40 dB.4Click Apply.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 181ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Antenna Disconnect AlarmI n t he Manage Alarms page, t here is an Antenna Disconnect Severity m enu, which pert ains only t o Rem ot e Access Unit s ( RAUs)  in an I nt erReach Spectrum  system . This feature is therefore not  applicable t o a FlexWave Prism  syst em  and should not  be changed from  its default  setting.
Manage Cont act  Alarm s  Page 182 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011MANAGE CONTACT ALARMS1To access the Manage Contact Alarms page, in t he Syst em  Menu bar, click Alarms >  Manage Contact Alarms.2I n t he Select m enu, select for which unit  cont act  alarm s are t o be configured.The Manage Contact Alarms page has the following Read- Only elem ents:•Unit Name—nam e assigned t o the unit•Contact Alarm—nam e assigned t o t he cont act  alarm  3I n t he Severity list , set  t he severit y level of t he cont act  alarm :•Minor ( default )•Major 4I n t he Mode list , set  the m ode for t he cont act  alarm :•Normally Open (default)•Normally Closed 5I n t he Name box, enter a nam e for t his alarm .•Ent er bet ween 1 and 255 alphanum eric charact ers. Spaces and Underscores are allowed, except  they cannot  be used as t he first  charact er.•I f you do not  want t o nam e the alarm , leave t he Name box em pt y.6I n t he Enabled select ion box for t he alarm  t hat  you want  t o m anage, do one of the following:•Select  the Enabled checkbox t o enable alarm  reporting for this alarm  t ype.•Rem ove (deselect )  t he checkm ark from  t he Enabled checkbox t o disable alarm  reporting for t his alarm  type.7Click Apply.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 183ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.ACKNOWLEDGE ALL ALARMS1To access the Acknowledge All Alarms page, in t he Syst em  Menu bar, click Alarms >  Acknowledge All Alarms.2Click Acknowledge All.3I n t he confirm at ion window, click OK.An All alarms have been acknowledged m essage displays.
Clear All Disconnect  Alarm s  Page 184 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011CLEAR ALL DISCONNECT ALARMSNOTE: Clear All Disconnects is not applicable to the Host—it is applicable only to PRUs.CAUTION! This procedure removes all information related to the disconnected units from the configuration database. 1To access the Clear All Disconnects page, in t he Syst em  Menu bar, click Alarms >  Clear All Disconnects.2Click Clear All Disconnects.Aft er approxim at ely one m inute, t he Syst em  Tree updates by rem oving t he disconnect  overlay from  t he unit  icon( s) . ( For an exam ple of t he disconnect overlay, see Table 11 on page 42.)
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 185ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.TROUBLESHOOTING ALARMSThis sect ion list s and defines alarm s that t he FlexWave Prism  EMS reports, and provides rem edies for t hose alarm s. The MI B Trap nam e for each alarm  is also list ed.Major Alarms—Host Unit Ala rm : Rem ot e  LostTrap: fwuHstSERFRmtLostFaultAlarm Code: AC1Definition: Rem ot e Unit  ( PRU/ URU)  not  com m unicating wit h Host .Remedy: Check t hat  the PRU/ URU has power and t hat  the power swit ch is on. Check t hat  at least  one Host SFP is connect ed t o t his PRU/ URU and has acceptable RX power.Major Alarms—Host Unit DARTs Ala rm : DART D C Supply FaultTrap: fwuHstDARTDCSupplyFaultAlarm Code: AC28Definition: DART card DC supply volt ages outside specificat ion.Remedy: Check whether the Host  supply volt age is in the range of 21-60 VDC. I f t he volt age is correct and the alarm  persists for 5 m inutes (m ay be transient  on st art up) , replace the DART.Ala rm : DART D ow nconvert e r 1  Syn thesizer UnlockedTrap: fwuHstDARTDwnCon1SynLockFaultAlarm Code: AC25Definition: DART downconvert er 1 synt hesizer unlocked.Remedy: The Downconverter 1 Synt hesizer Unlocked alarm  can occur during Host reboot s and DART hotswaps. I f the alarm  persists aft er 5 m inutes, replace the DART.Ala rm : DART D ow nconvert e r 2  Synthesize r Unlock edTrap: fwuHstDARTDwnCon2SynLockFaultAlarm Code: AC26Definition: DART downconvert er 2 synt hesizer unlocked.Remedy: The Downconverter 2 Synt hesizer Unlocked alarm  can occur during Host reboot s and DART hotswaps. I f the alarm  persists aft er 5 m inutes, replace the DART.
Troubleshoot ing Alarm s  Page 186 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ala rm : DART FaultTrap: fwuHstDARTFaultAlarm Code: AC29Definition: Sum m ary of DART Downconverter 1 Synt hesizer Unlocked, Downconverter 2 Synt hesizer Unlocked, Upconvert er Synthesizer Unlocked, DC Supply Fault alarm s, and DART FPGA st at us.Remedy: I nspect alarm s (Alarms > View Current Alarms) for upconvert er/ downconvert er/ DC supply alarm s on the sam e Host  DART and follow t he rem edies for t hose alarm s. I f none of these alarm s are found, unplug and replug t he DART in the Host . I f t he alarm  persist s, replace the DART.Ala rm : DART H a rdw ar e Mism atchTrap: fwuHstDARTHardwareMismatchFaultAlarm Code: AC32Definition: Host  DART does not  support  t he selected passband. Fault  occurs when a Host  DART is replaced wit h another DART of t he incorrect  type.Remedy: I nst all a DART t hat  supports the select ed passband. I f t he Host DART position is t o be changed t o a different frequency band, rem ove and clear the DART configuration (Unit Configuration > Clear DART Configuration) , inst all the new DART, set t he passband, and establish the new link (System Configuration > Configure DART Links) .Ala rm : DART Ove r Dr iveTrap: fwuHstDARTOverDriveFaultAlarm Code: AC30Definition: DART forward RF input  too high.Threshold: + 19 dBmRemedy: Reduce the Host  DART forward RF input  level.Ala rm : DART Upcon vert er Synt hesizer UnlockedTrap: fwuHstDARTUpConSynLockFaultAlarm Code: AC27Definition: DART upconvert er synt hesizer unlocked.Remedy: The DART Upconvert er Synt hesizer Unlocked alarm  can occur during Host reboot s and DART hotswaps. I f the alarm  persists aft er 5 m inutes, replace the DART.Ala rm : FLM  D ow ncon vert er Fa ultTrap: fwuHstBTSFLMFailFaultAlarm Code: AC47Definition: Forward Link Monit or ( FLM) fault  active.Remedy: I f alarm  persist s, then replace the DART.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 187ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Ala rm : M odule  M issing FaultTrap: fwuHstModuleMissingFaultAlarm Code: AC2Definition: One of t he Host  pluggable m odules is m issing (DART/ SFP) .Remedy: Eit her replace Host  m odule or clear DART configuration ( Unit Configuration > Clear DART Configuration) .Ala rm : RLM  Upcon vert  FaultTrap: fwuHstRLMUpconvertFailureFaultAlarm Code: AC48Definition: Reverse Link Monit or ( RLM) fault  act ive.Remedy: Running Syst em  Test ( System Configuration > Perform System Test) wit h un- t erm inat ed Host  DARTs m ay cause a false RLM Upconvert Fault. Ensure that  all Host  DARTs are t erm inated before running Syst em  Test . I f alarm  persist s, then replace t he DART.Major Alarms—Host SeRF ModulesAla rm : Fa n Fa ultTrap: fwuHstSysCardFanFaultAlarm Code: AC6Definition: Fan not funct ioning.Remedy: Verify intake and exhaust vent s are clear of obst ruct ions and/ or debris. I f alarm  persists, replace Fan Module.Ala rm : Se RF Fa ultTrap: fwuHstSERFFaultAlarm Code: AC10Definition: Sum m ary of SeRF Synt hesizer Unlocked alarm  and SeRF FPGA st at us.Remedy: Check for relat ed Host  SeRF alarm s (Alarms > View Current Alarms) . I f no SeRF alarm s exist , FPGA is faulty;  replace Host  SeRF Module.Ala rm : SeRF Synt he sizer Unlock e dTrap: fwuHstSERFSynthAlarmFaultAlarm Code: AC9Definition: SeRF synthesizer unlocked. Remedy: Check Host  reference clock set t ings (Unit Configuration > Edit Properties) . Reseat  t he Syst em  Module. I f reference clock source is external, ver ify 10 MHz clock source and connect ion. I f reference clock source is internal and the alarm s persist s, replace t he Host Syst em  Module.
Troubleshoot ing Alarm s  Page 188 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ala rm : Te m pe ra t ure  H ighTrap: fwuHstOverTempFaultAlarm Code: AC4Definition: Tem perat ure above operat ing lim it .Threshold: 62° CRemedy: Check for Host  Fan Fault  alarm  (Alarms > View Current Alarms) . Verify that am bient  tem perat ure is less t han 50° C. Verify Host air intake and exhaust  vent s are clear of debris.Major Alarms—Host Unit SFPs Ala rm : Opt ical Ove r DriveTrap: fwuHstSERFOptOverDriveFaultAlarm Code: AC16Definition: SFP opt ical receive input  power above specificat ion.Threshold: Threshold for I R is 1 dBm , and for LR is - 9 dBm  Remedy: Reduce t he opt ical receive level by adding optical at t enuat ion. Replace optical at t enuator if fault y.Ala rm : Opt ica l RX N o Ligh tTrap: fwuHstSERFOptRxNoLightFaultAlarm Code: AC14Definition: No signal det ect ed by optical receiver.Remedy: Check for broken fiber opt ic cable;  replace if found. Check for disconnect ed fiber opt ic cable;  reconnect  cable if necessary. Check that  the PRU/ URU has power.Ala rm : Opt ical Tra nsm it t e r Fa ultTrap: fwuHstSERFOptLaserFaultAlarm Code: AC15Definition: SFP opt ical t ransm it t er failed.Remedy: Replace Host SFP.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 189ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Major Alarms—Remote UnitsThe following alarm s apply to bot h the Prism  Rem ot e Unit  ( PRU)  and t he URH Rem ot e Unit  (URU).Ala rm : M odule  M issing FaultTrap: fwuRmtModuleMissingFaultAlarm Code: AC68Definition: A pluggable m odule is m issing from  a Rem ote Unit , and can be any of t he following:  DART, SFP, LNA, LPA, or PD. Remedy: Eit her replace the PRU/ URU m odule or clear DART configurat ion ( Unit Configuration > Clear DART Configuration) .Major Alarms—PRU/URU DARTsThe following alarm s apply to DARTs inst alled in a Prism  Rem ot e Unit  ( PRU)  or a URH Rem ot e Unit  ( URU).Ala rm : DART D C Supply FaultTrap: fwuRmtDARTDCSupplyFaultAlarm Code: AC97Definition: DART card DC supply volt ages outside specificat ion.Remedy: I f the alarm  persists for 5 m inutes ( m ay be t ransient on st artup), replace the DART.Ala rm : DART FaultTrap: fwuRmtDARTFaultAlarm Code: AC101Definition: Sum m ary of DART Downconverter 1 Synt hesizer Unlocked, Downconverter 2 Synt hesizer Unlocked, Upconvert er Synthesizer Unlocked, DC Supply Fault alarm s, and DART FPGA st at us.Remedy: I nspect alarm s (Alarms > View Current Alarms) for upconvert er/ downconvert er/ DC supply alarm s on the PRU/ URU DART and follow t he rem edies for those alarm s. For PRU DART only—if none of t hese alarm s are present, power cycle t he RF Module. I f the alarm  persists, replace the RF Module.
Troubleshoot ing Alarm s  Page 190 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ala rm : DART H a rdw ar e Mism atchTrap: fwuRmtDARTHardwareMismatchFaultAlarm Code: AC98Definition: Host  DART does not  support  t he selected passband. Fault  occurs when a Host  DART is replaced wit h another DART of t he incorrect  type.Remedy: I nst all a DART t hat supports the select ed passband. I f t he posit ion of the PRU/ URU DART is t o be changed to a different frequency band, rem ove and clear t he DART configurat ion ( Unit Configuration > Clear DART Configuration), install the new DART, set t he passband, and est ablish the new link ( System Configuration > Configure DART Links) .Ala rm : Dow n convert Fa ultTrap: fwuRmtDownconvertfailureFaultAlarm Code: AC128Definition: Band specific alarm  raised during Reverse Link Monit oring on PRU/ URU.Remedy: Ret ry Syst em  Test ( System Configuration > Perform System Test). I f alarm  persist s, replace the DART.Ala rm : Dow n converter  1  Syn t he sizer UnlockedTrap: fwuRmtDARTDwnCon1SynLockFaultAlarm Code: AC93Definition: DART downconvert er 1 synt hesizer unlocked.Remedy: The Downconverter 1 Synt hesizer Unlocked alarm  can occur during Host reboot s and DART hotswaps. I f the alarm  persists aft er 5 m inutes, replace the DART.Ala rm : Dow n converter  2  Syn t he sizer UnlockedTrap: fwuRmtDARTDwnCon2SynLockFaultAlarm Code: AC94Definition: DART downconvert er 2 synt hesizer unlocked.Remedy: The Downconverter 2 Synt hesizer Unlocked alarm  can occur during Host reboot s and DART hotswaps. I f the alarm  persists aft er 5 m inutes, replace the DART.Ala rm : FW D Ca l Tone  FaultTrap: fwuRmtDownlinkCalToneFailureFaultAlarm Code: AC124Definition: Forward calibrat ion t one not  at  expect ed level.Remedy: Ret ry Syst em  Test ( System Configuration > Perform System Test). I f alarm  persist s, replace the DART.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 191ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Ala rm : REV Test  Ton e LowTrap: fwuRmtUplinkFailureDetectLowFaultAlarm Code: AC125Definition: Reverse test t one not at  expect ed level.Remedy: Ret ry Syst em  Test ( System Configuration > Perform System Test) . I f alarm  persist s, replace the DART.Ala rm : Upconver t  FaultTrap: fwuRmtUpconvertfailureFaultAlarm Code: AC126Definition: Band specific alarm  raised during Forward Link Monit oring on PRU/ URU.Remedy: Ret ry Syst em  Test ( System Configuration > Perform System Test) . I f alarm  persist s, replace the DART.Ala rm : Upconve rt I nde t erm inat eTrap: fwuRmtUpconIndetFaultAlarm Code: AC129Definition: Band specific alarm  raised during Forward Link Monit oring on PRU/ URU.Remedy: Ret ry Syst em  Test ( System Configuration > Perform System Test) . I f alarm  persist s, replace the DART.Ala rm : Upconver t er Synt hesize r UnlockedTrap: fwuRmtDARTUpConSynLockFaultAlarm Code: AC95Definition: DART upconvert er synt hesizer unlocked.Remedy: The DART Upconvert er Synt hesizer Unlocked alarm  can occur during Host reboot s and DART hotswaps. I f the alarm  persists aft er 5 m inutes, replace the DART.Major Alarms—PRU/URU SeRF ModulesThe following alarm s apply to a SeRF m odule installed in a Prism  Rem ot e Unit  ( PRU)  or in a URH Rem ot e Unit  ( URU) .Ala rm : Fa n Under SpeedTrap: fwuRmtFanUnderSpeedFaultAlarm Code: AC77Definition: Fans operating below expect ed RPM.Remedy: Verify intake and exhaust vent s are clear of obst ruct ions and/ or debris. I f alarm  persists, replace Fan Module.
Troubleshoot ing Alarm s  Page 192 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ala rm : Host  LostTrap: fwuRmtSeRFHstLostFaultAlarm Code: AC88Definition: Host  not  com m unicat ing wit h PRU/ URU.Remedy: Check t hat  the Host  has power and t hat  t he power swit ch is on. Check that  at  least  one of t he PRU/ URU SFPs is connect ed to t his Host and has acceptable RX power.Ala rm : Se RF Fa ultTrap: fwuRmtSERFFaultAlarm Code: AC87Definition: Sum m ary of SeRF Synt hesizer Unlocked alarm  and SeRF FPGA st at us.Remedy: Check for relat ed Host SeRF alarm s (Alarms > View Current Alarms) . I f no SeRF alarm s exist , FPGA is faulty;  replace PRU SeRF Module.Ala rm : SeRF Synt he sizer Unlock e dTrap: fwuRmtSERFSynthAlarmFaultAlarm Code: AC86Definition: SeRF synthesizer unlocked. Remedy: Ensure that  the PRU/ URU has an opt ical input signal. Check t hat  the Host reference clock is properly configured and is not  in alarm ;  otherwise replace the PRU/ URU SeRF m odule.Ala rm : Te m pe ra t ure  H ighTrap: fwuRmtOverTempFaultAlarm Code: AC73Definition: Tem perat ure above operat ing lim it .Threshold: 95° CRemedy: Check for PRU/ URU Fan Fault  alarm  (Alarms > View Current Alarms). Verify that  am bient  t em perat ure is less t han 50° C. Verify that t he air int ake and exhaust  vent s for the PRU/ URU are clear of debris.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 193ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Major Alarms—PRU/URU SFPs The following alarm s apply to SFPs inst alled in a Prism  Rem ot e Unit ( PRU)  or in a URH Rem ot e Unit  ( URU).NOTE: Cascading Remote Units is not supported in this release. Alarms that pertain to cascaded Remote Units are included as reference only.Ala rm : Ex ce ss Conn ect ionsTrap: fwuRmtExcessConnFaultAlarm Code: AC134Definition: Two or m ore PRU/ URU connected t o a single cascaded PRU/ URU, or a nint h PRU/ URU connected in cascade, or there are m ore out going fibers than incom ing fibers on a PRU/ URU in a cascade. Remedy: Connect  fiber optic cables per cascade connect ion rules. Refer to appropriat e inst allat ion guide for det ails.Ala rm : Fiber  Conn ect ion  M ism atchTrap: fwuRmtFiberConnMismatchFaultAlarm Code: AC133Definition: Fiber opt ic cable connect ions bet ween cascaded PRU/ URUs not  following SFP connection rules.Remedy: Connect  fiber optic cables per cascade connect ion rules. Refer to appropriat e inst allat ion guide for det ails.Ala rm : I nva lid D evice  Conn ect ionTrap: fwuRmtInvalidDevConnFaultAlarm Code: AC135Definition: PRU/ URU is connected t o a DRU or vice versa.Remedy: Ensure that  cascaded Rem otes are all the sam e t ype ( t hat  is, a PRU to a PRU and a DRU t o a DRU) . Refer t o appropriate inst allat ion guide for det ails.Ala rm : Opt ica l Over DriveTrap: fwuRmtSERFOptOverDriveFaultAlarm Code: AC84Definition: SFP opt ical receive input  power above specificat ion.Threshold: Threshold for I R is 1 dBm , and for LR is - 9 dBm  Remedy: Reduce t he opt ical receive level by adding opt ical attenuat ion. Replace opt ical at tenuat or if faulty.
Troubleshoot ing Alarm s  Page 194 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ala rm : Opt ica l RX N o Ligh tTrap: fwuRmtSERFOptRxNoLightFaultAlarm Code: AC82Definition: No signal det ect ed by optical receiver.Remedy: Check/ repair opt ical overdrive condit ions ( Unit Information > View Optical Ports). Ensure that fiber optic connections are clean. Check for kinks or sharp bends in t he fiber optic cable;  replace fiber opt ic cable if unable to correct any problem s found.Ala rm : Opt ical Tra nsm it t e r Fa ultTrap: fwuRmtSERFOptLaserFaultAlarm Code: AC83Definition: SFP opt ical t ransm it t er failed.Remedy: Replace Host SFP.Major Alarms—PRU or URU Duplexer The following alarm s apply to Duplexers, which are inst alled in t he Prism  Rem ot e Unit ( PRU)  or t he URH Rem ot e Unit  ( URU).Ala rm : Duple xer  M ism at chTrap: fwuRmtDuplexerFreqMismatchFaultAlarm Code: AC116Definition: Configured frequency range not  supported by Duplexer.Remedy: Change DART passband t o fit wit hin duplexer frequency range ( System Configuration >  Configure DART Links). I f alarm  persists, cont act  ADC.Major Alarms—PRU or URU LNAThe following alarm s apply t o LNAs inst alled in a Prism  Rem ot e Unit ( PRU)  or URH Rem ot e Unit  (URU).Ala rm : LN A Pow er Fa ultTrap: fwuRmtLNAPowerFaultAlarm Code: AC115Definition: PRU/ URU Low Noise Am plifier ( LNA)  Power fault.Remedy: The low noise am plifier has an int ernal error. I f alarm  persist s, replace the RF Module.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 195ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Major Alarms—PRU or URU LPAThe following alarm s apply t o LPAs inst alled in a Prism  Rem ot e Unit  (PRU)  or URH Rem ot e Unit  (URU).Ala rm : LPA D C FaultTrap: fwuRmtLPADcFaultAlarm Code: AC109Definition: PRU/ URU Linear Power Am plifier ( LPA)  DC fault .Remedy: Caused by int ernally det ect ed problem  wit h t he LPA.  I m pact is loss of RF service. Reset  LPA.  I f alarm  persist s, replace the RF Module.Ala rm : LPA D isabledTrap: fwuRmtLPADisableFaultAlarm Code: AC105Definition: PRU/ URU Linear Power Am plifier ( LPA)  disabled due t o an int ernally detected problem .  (VSWR, DC, Loop Fault, Low Power, or Tem perat ure High alarm ) .Remedy: The LPA is disabled because of an int ernally det ect ed problem . Perform  an LPA Reset .  I f the fault persists replace t he RF Module.Ala rm : LPA Loop FaultTrap: fwuRmtLPALoopFaultAlarm Code: AC110Definition: PRU/ URU Linear Power Am plifier ( LPA)  Loop fault.Remedy: Caused by int ernally det ect ed problem  wit h t he LPA.  I m pact is loss of RF service. Lower DART(s)  gain by 10 dB, reset  the LPA, and ret urn gain t o previous value.  I f alarm  persists, replace RF Module.Ala rm : LPA Low  Pow er Fa ultTrap: fwuRmtLPALowPowerFaultAlarm Code: AC111Definition: I nt ernal Linear Power Am plifier ( LPA)  Low Power fault.  Gain of one or m ore int ernal am plifiers out side of specificat ion).Remedy: Caused by int ernally det ect ed problem  wit h t he LPA.  I m pact is loss of RF service. Reset  LPA.  I f alarm  persist s, replace the RF Module.Ala rm : LPA M issingTrap: fwuRmtLPADetectFaultAlarm Code: AC112Definition: Linear Power Am plifier ( LPA)  det ect ion fault.  LPA m issing from  PRU.Remedy: Cause is fault y RF Module.  I m pact is loss of RF service. I f alarm  persist s, replace the RF Module.
Troubleshoot ing Alarm s  Page 196 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ala rm : LPA Over Pow erTrap: fwuRmtLPAOverPowerFaultAlarm Code: AC107Definition: PRU/ URU Linear Power Am plifier ( LPA)  out put  power level above operating lim it .Threshold: Variable by LPA band.Remedy: Causes include, forward pat h gains are set  too high or Host RF input  levels are too high.  I m pact  is loss of RF service. Reduce PRU forward gain ( "Syst em  Configurat ion ->  Configure Rem ot e Forward Gain") . Reset  t he LPA, and t hen m onit or RF out put  power levels.  Adjust  gain to acceptable values.  I f t he alarm  persists, replace t he RF Module.Ala rm : LPA VSW R Fa ultTrap: fwuRmtLPAVswrFaultAlarm Code: AC108Definition: PRU/ URU Linear Power Am plifier ( LPA)  VSWR fault .Threshold: 3: 1Remedy: Causes include, fault y RF Module, faulty/ loose RF Module t o bulkhead cable, faulty/ loose external light ning arrest or, cable or antenna. I m pact  is loss of RF service. Reset  LPA.  I f alarm  persist s, replace the RF Module.Major Alarms—PRU or URU Power DetectorAla rm : RF Pow e r LowTrap: fwuRmtRFPowerFaultAlarm Code: AC114Definition: PRU/ URU RF Output Power below m inim um  t hreshold.Threshold: 0 dBm ;  can be configured by user, see “ Set  RF Power Low Threshold”  on page 180.Remedy: Check for Host DART underdrive alarm  or low RF input  from  BTS. Check t he Host  and Rem ot e forward gains are set  correct ly.Ala rm : Syst em  VSW R Fa ultTrap: fwuRmtSystemVswrFaultAlarm Code: AC113Definition: PRU/ URU VSWR m easurem ent  above specificat ion.Threshold: 3: 1Remedy: Perform  cable sweeps on external ant enna cable syst em .  Put  a load on t he PRU/ URU by disconnect ing the ext ernal antenna cable to determ ine if the source of t he VSWR condit ion is int ernal or external. I f  int ernal, replace the RF Module.  I f ext ernal, t roubleshoot  and determ ine source of high VSWR reading.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 197ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Minor Alarms—Host Unit DARTs Ala rm : DART ALC Lim it ingTrap: fwuHstDARTALCLimitingFaultAlarm Code: AC33Definition: Host  DART forward path Aut om atic Level Cont rol act ive.Threshold: + 19 -  Fwd GainRemedy: Decrease t he Host  DART forward path gain (System Configuration > Configure Host Forward Gain) , or reduce the RF signal level from  t he BTS/ BDA.Ala rm : DART Un der Dr iveTrap: fwuHstDARTUnderDriveFaultAlarm Code: AC31Definition: DART forward RF input  signal below the norm al operat ing lim it.Threshold: + 5 -  Fwd Gain -  20Remedy: Check t hat  an RF signal is present  at t he Host DART forward input . I f an RF signal is present, t hen increase the forward gain of t he Host  DART. I f t he alarm  does not clear when gain is at m axim um , increase the power of t he BTS/ BDA RF signal.Ala rm : RLM Upconver t  I ndet er m inateTrap: fwuHstRLMUpConIndetFaultAlarm Code: AC49Definition: Unable t o run RLM due t o Host  Reverse Gain being set  too low.Remedy: I ncrease Host  Reverse Gain ( System Configuration >  Configure Host Forward Gain).Minor Alarms—Host Unit SeRF ModuleAla rm : Te m pe ra t ure  LowTrap: fwuHstUnderTempFaultAlarm Code: AC5Definition: Tem perat ure below operating lim it .Threshold: 0° CRemedy: Verify that  am bient  tem perat ure is great er t han 0° C;  fix low tem perat ure condit ion in t he Host 's location.
Troubleshoot ing Alarm s  Page 198 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Minor Alarms—Host Unit SFPs Ala rm : Opt ical RX High BERTrap: fwuHstSERFOptRxBERFaultAlarm Code: AC13Definition: High bit error rat e ( BER) det ect ed by fiber optic receiver.Threshold: 0.00001Remedy: Check/ repair opt ical overdrive condit ions ( Unit Information > View Optical Ports). Ensure that fiber optic connections are clean. Check for kinks or sharp bends in t he fiber optic cable;  replace fiber opt ic cable if unable to correct any problem s found.Ala rm : Opt ical Under  D riveTrap: fwuHstSERFOptUnderDriveFaultAlarm Code: AC17Definition: SFP opt ical receive input  power below specificat ion.Threshold: Threshold for I R is - 1 dBm , and for LR is -27 dBm  Remedy: Check fiber opt ic cable for t oo m uch at tenuat ion and/ or dirty connect ions. Check SFP t ype ( wavelengt h or I R/ LR)  being used;  replace the SFP if it  is the wrong t ype.Minor Alarms—PRU/URU DARTsThe following alarm s apply t o DARTs inst alled in a Prism  Rem ot e Unit  ( PRU)  or in a URH Rem ot e Unit  ( URU) .Ala rm : DART Tem per a t ur e HighTrap: fwuRmtDARTOverTempFaultAlarm Code: AC99Definition: DART t em perat ure above operat ing lim it .Threshold: 85° CRemedy: Check t he PRU/ URU fans. Check the air flow around the PRU/ URU. Ensure that  t he PRU/ URU door is closed and that  t he am bient tem perat ure is less than 50° C. Check that  t he heat sink m at erial on the PRU/ URU DARTs has not  been dam aged. I f the alarm  persist s, replace RF Module.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 199ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Ala rm : DART Tem per a t ur e LowTrap: fwuRmtDARTLowTempFaultAlarm Code: AC100Definition: DART t em perat ure below operat ing lim it .Threshold: - 4 0° CRemedy: Check am bient condit ions;  fix low tem perat ure conditions in t he DART's locat ion.Ala rm : Dela y Out Of Ra ngeTrap: fwuRmtRangingFaultAlarm Code: AC96Definition: PRU/ URU delay set t ings out side t he valid range.Remedy: Ent er forward and reverse delay values (System Configuration > Configure Delay) wit hin t he displayed range.Minor Alarms—PRU/URU SeRF ModulesThe following alarm s apply t o SeRF m odules installed in a Prism  Rem ot e Unit ( PRU) or in a URH Rem ote Unit  ( URU).Ala rm : Fa n Over  SpeedTrap: fwuRmtFanOverSpeedFaultAlarm Code: AC76Definition: Fans operating above expect ed RPM.Remedy: I f alarm  persist s, t hen replace the Fan Module.Ala rm : Te m pe ra t ure  LowTrap: fwuRmtUnderTempFaultAlarm Code: AC74Definition: Tem perat ure below operating lim it .Threshold: Minus 40° CRemedy: Verify that  am bient  t em perat ure is greater t han -40° C;  fix low tem perat ure condit ion at  the location of t he PRU/ URU.
Troubleshoot ing Alarm s  Page 200 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Minor Alarms—PRU/URU SFPsThe following alarm s apply to SFPs inst alled in a Prism  Rem ot e Unit ( PRU)  or in a URH Rem ot e Unit  ( URU).Ala rm : Opt ical RX High BERTrap: fwuRmtSERFOptRxBERFaultAlarm Code: AC81Definition: High bit error rat e ( BER) det ect ed by fiber optic receiver.Threshold: 0.00001Remedy: Check/ repair opt ical overdrive condit ions ( Unit Information > View Optical Ports). Ensure that fiber optic connections are clean. Check for kinks or sharp bends in t he fiber optic cable;  replace fiber opt ic cable if unable to correct any problem s found.Ala rm : Opt ical Under  D riveTrap: fwuRmtSERFOptUnderDriveFaultAlarm Code: AC85Definition: SFP opt ical receive input  power below specificat ion.Threshold: Threshold for I R is - 1 dBm , and for LR is -27 dBmRemedy: Check fiber opt ic cable for t oo m uch at tenuat ion and/ or dirty connect ions. Check SFP t ype ( wavelengt h or I R/ LR)  being used;  replace the SFP if it  is the wrong t ype.Remedy: Check for any m aj or alarm s ( Alarms > View Current Alarms). Follow t he rem edies for those alarm s.Minor Alarms—PRU or URU LPAs The following alarm s apply t o LPAs inst alled in a Prism  Rem ote Unit ( PRU)  or URH Rem ot e Unit  (URU).Ala rm : LPA Over Tem per atureTrap: fwuRmtLPAHighTempFaultAlarm Code: AC106Definition: PRU/ URU LPA above operat ing lim it .Threshold: 89° CRemedy: Check am bient t em perature. Fix any t em perat ure problem s in t he area of t he PRU/ URU. Check the PRU/ URU t em perat ure. Replace fan if it  is faulty and correct  any air flow problem s ar ound t he PRU/ URU. Reset  LPA. I f the alarm  persist s, replace t he RF Module.
Alar m sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 201ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Contact Alarms—Host System CardAla rm : Host  M a j or Con t act  Ala rm  Out put  Act iveTrap: fwuHstContactAlarmOutput1Alarm Code: AC41Definition: User configurable Maj or Contact Alarm  Out put  act ive.Remedy: Check for any m aj or alarm s ( Alarms > View Current Alarms). Follow t he rem edies for t hose alarm s.Ala rm : Host  M inor  Contact  Alarm  Output  Act iveTrap: fwuHstContactAlarmOutput2Alarm Code: AC42Definition: User configurable Minor Cont act  Alarm  Output active.Remedy: Check for any m inor alarm s (Alarms > View Current Alarms). Follow the rem edies for t hose alarm s.Ala rm : Host  Cont act  Alarm  I nput  1Trap: fwuHstContactAlarmInput1Alarm Code: AC43Definition: Host  Cont act  Alarm  I nput  # 1 active. Alarm  level is user configurable.Remedy: Check equipm ent connect ed t o Host  Cont act  Alarm  I nput  1, or check cont act  polarit y ( t hat  is, Norm ally Open or Norm ally Closed) .Ala rm : Host  Cont act  Alarm  I nput  2Trap: fwuHstContactAlarmInput2Alarm Code: AC44Definition: Host  Cont act  Alarm  I nput  # 2 active. Alarm  level is user configurable.Remedy: Check equipm ent connect ed t o Host  Cont act  Alarm  I nput  2, or check cont act  polarit y ( t hat  is, Norm ally Open or Norm ally Closed) .Contact Alarms—Remote UnitThe following alarm s can apply to t he Prism  Rem ot e Unit ( PRU) or t he URH Rem ot e Unit ( URU) .Ala rm : Cont a ct  Alarm  I nput 1  Act iveTrap: fwuRemoteContactAlarmInput1Alarm Code: AC65Definition: Rem ot e Unit  ( PRU/ URU)  Cont act  Alarm  I nput  # 1 active.Remedy: Check equipm ent  connect ed to Rem ot e Unit  ( PRU/ URU)  Cont act  Alarm  I nput  1, or check cont act polarit y ( i.e., Norm ally Open or Norm ally Closed) .
Troubleshoot ing Alarm s  Page 202 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ala rm : Cont a ct  Alarm  I nput 2  Act iveTrap: fwuRemoteContactAlarmInput2Alarm Code: AC66Definition: Rem ot e Unit  ( PRU/ URU)  Cont act  Alarm  I nput  # 2 active.Remedy: Check equipm ent connect ed to Rem ot e Unit  ( PRU/ URU)  Cont act Alarm  I nput  2, or check cont act polarit y ( i.e., Norm ally Open or Norm ally Closed) .
FlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 203ADCP- 77- 177  • I ssue 1 • July 2011 © 2011 ADC Telecommunications, Inc.USERSUnderst anding FlexWave EMS User Accounts ........................................................................... 204Manage Users Page .............................................................................................................. 205Add a New User ............................................................................................................. 205Change a User’s Access Level ........................................................................................... 207Change a User Password ................................................................................................. 208Change Your Personal Password ............................................................................................. 210Recovering a Password ......................................................................................................... 211Delet e a User ...................................................................................................................... 212This sect ion t ells you how to m anage users, passwords, and user access t o a Prism  sy stem .Topics Page
Underst anding FlexWave EMS User Account s  Page 204 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011UNDERSTANDING FLEXWAVE EMS USER ACCOUNTSThe EMS provides securit y, which can be broadly classified as:  •User Authentication, which defines t he way a user is identified prior t o being allowed to log on t o the EMS. User Aut henticat ion ensures t hat only known users have access by providing a m et hod of ident ifying each user t hrough a user I D and password.•User Authorization, which involves m anaging t he user’s privileges in t he Prism  net work m anagem ent  infrastruct ure. Aut horization is based on the concept of user access syst em  configuration restrictions. There are t hree user- access account s that can be assigned by the adm in:•adm in—t he default  user account t hat  has unrestricted access t o all EMS user account s and m anagem ent capabilit ies. To prot ect  against  unaut horized access to t he Prism  net work, t he user assigned t he adm in role should follow t he process described in “ Change Your Personal Password”  on page 210 t o change the password for t he adm in user account.•Net work Manager—has read and writ e access to all syst em  funct ions except  user account  m anagem ent.•Net work User—has read only perm issions into the syst em .There are also t wo default  user- access account s for the Rem ot e that  cannot  be delet ed or changed:•operator—is only supported on t he Craft  int erface of a Rem ot e, and provides Read Only access t o m ost of the Prism  Rem ot e funct ions. However, t he operatorlogin can be only t o change t he Rem ot e Capacit y set ting ( see “Set t he Capacity for a New Rem ot e Unit  RSI  Board”  on page 162) .•viewer—has Read Only rights for Prism  and URH Rem ot es.FlexWave EMS prevent s a login in which the user enters an invalid User I D or password. Table 24 lists t he default user account s and passwords.Table 24. Default User Account Device AccessUser Name Default PasswordPort AccessHost Remoteadmin adc123 Network andCraft ports N/Aviewer viewer N/A Craft portoperator operator N/A Craft port
User sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 205ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.MANAGE USERS PAGEThe Manage Users page allows you t o:•“ Add a New User” on page 205•“ Change a User’s Access Level”  on page 207•“ Change a User Password”  on page 208.Add a New UserCAUTION! If Auto Complete (that is, remember username/password) is turned on in your web browser, when you add a new user, the browser automatically fills in Prism user names and passwords with the saved information. To avoid this, disable Auto Complete in your browser.1To access the Manage Users page, in t he Syst em  Menu bar, click Users >  Manage Users.2I n t he Manage Users page, click Add New User.3Do t he following in t he Add New User page:aI n t he Name box, ent er a user nam e, which m ust st art wit h an alphabet ical charact er, cont ain at least  5 characters ( alphanum eric or underscore only), and cont ain no spaces. bI n t he Password box, ent er a password specific t o t his user. The Password m ust contain at  least 6 alphanum eric or special characters, and cannot  be em pty or contain spaces.cI n t he Confirm Password box, enter t he exact sam e password as you entered in t he Password box.dI n t he Access Level m enu, select  the access level for t his user. See “ Underst anding FlexWave EMS User Accounts”  on page 204.
Manage Users Page  Page 206 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20114Click Add. The following m essage displays, list ing the new user by Name. Addit ionally, t he Add New User fields are cleared so you can add ot her users as needed.5I n t he Syst em  Menu bar, click Users >  Manage Users t o see an updat ed list  of users.
User sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 207ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Change a User’s Access Level1I n the Syst em  Menu bar, click Users >  Manage Users t o see a list  of users.2To change a user’s access, select  the user in t he Select colum n, which activat es the operational but tons.3Click Change Access.4Verify that  t he nam e list ed for Selected User is the user  whose access level you want t o change.5I n t he Change Access Level page, use t he Access Level m enu t o change t he access level for t his user. For further inform at ion on access levels, see “ Underst anding FlexWave EMS User Account s”  on page 204.6Click Change Access.The Access Level for <username> is changed successfully m essage displays.
Manage Users Page  Page 208 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20117I n t he Syst em  Menu bar, click Users >  Manage Users t o see an updat ed list  of users.At  this tim e the operat ional buttons, wit h the except ion of Add New User and Refresh, will be disabled, as no user is select ed.Change a User PasswordNOTE: Only the admin user or a user with the Network Manager access level can change the password of another user.1I n the Syst em  Menu bar, click Users >  Manage Users t o see a list  of users.2To change a user’s password, select  t he user in t he Select colum n, which act ivat es the operat ional but t ons.
User sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 209ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.3Click Change Password.4I n t he Change Password page, do t he following:aVerify that  the nam e list ed for Selected User is for t he user whose password you want t o change.bI n t he New Password box, enter a new password for this user. The Password m ust  cont ain at  least 6 alphanum eric or special characters, and cannot  be em pty or contain spaces.cI n t he Confirm Password box, ent er t he exact  sam e password as you ent ered in t he New Password box.5Click Change Password.The Password changed successfully m essage displays.
Change Your Personal Passw ord  Page 210 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011CHANGE YOUR PERSONAL PASSWORD1I n the Syst em  Menu bar, click Users >  Change Password.2I n t he Change Password page, do t he following:aI n t he Old Password box, ent er your exist ing password.bI n t he New Password box, enter a new password for this user. The Password m ust  cont ain at  least  6 alphanum eric or special charact ers, and cannot  be em pty or contain spaces.cI n t he Confirm Password box, enter t he exact sam e password as you entered in t he New Password box.3Click Change Password.The Password for <username> has been changed m essage displays.
User sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 211ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.RECOVERING A PASSWORDI f a user changes his or her password and t hen forget s t he new password, the adm in user needs t o recreat e an account  for t he user. I f the password is changed and then forgot t en for t he adm in user, the adm in should cont act  ADC for assist ance.
Delet e a User  Page 212 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011DELETE A USER1I n the Syst em  Menu bar, click Users >  Manage Users t o see a list  of users.2Select  the user whose account  is t o be delet ed in t he Select colum n, which act ivat es the operat ional but t ons.3Click Delete. 4I n t he confirm at ion dialog, which ident ifies t he user being delet ed, click OK.The  User deleted successfully m essage displays and t he Users t able is updat ed in the Manage Users page.
FlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 213ADCP- 77- 177  • I ssue 1 • July 2011 © 2011 ADC Telecommunications, Inc.UPGRADING THE SYSTEM AND UNITSUpload t he Upgrade Files ...................................................................................................... 214Updat ing a Prism  Syst em ...................................................................................................... 216Com m it  the Upgr ade ............................................................................................................ 219Abort  an Update .................................................................................................................. 220Updat ing I ndividual Unit s ...................................................................................................... 221Upgrading a Prism  syst em  or a unit wit hin a Prism  system  is a three- st ep process, in which you do t he following:1Upload t he upgrade file.2Use t he upgrade file t o updat e t he syst em  or unit .3Com m it  the updat e.Topics Page
Upload the Upgrade Files  Page 214 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011UPLOAD THE UPGRADE FILESUse t he Upload page t o t ransfer the required upgrade files from  a com puter or laptop t o your Prism  syst em  or unit .Each soft ware upgrade requires the following files t o go from  one version t o the next :• upgrade.x-y.tar.gz.md5• upgrade.x-y.tar.gzwhere•x ident ifies the version from  which t he unit / syst em  is being upgraded•y ident ifies the version to which t he unit / system  is being upgraded.NOTE: Each upgrade file set is designed to upgrade a specific EMS release, which may be updating the EMS GUI or unit firmware, or both. If you try to apply upgrade files to a system/unit that is not running the EMS release for which the upgrade files are designed, the update will abort when it runs its version check.Do t he following t o upload t he required upgrade files:1Cont act  ADC t o obtain the appropriate upgrade files ( see “ Appendix C:  Cont act ing ADC/ TE Connect ivit y”  on page 297). 2Verify that  t here is sufficient  space on the disk drive to accom m odat e t he upgrade files t hat  you need to upload.3Save t he upgrade files to your com puter.4To access the Upload page, in t he Syst em  Menu bar, click Upgrades >  Upload.5Click Browse.6I n t he Choose File dialog, navigat e t o where the upgrade *.tar.gz and *.tar.gz.md5 files are st ored.
Upgrading t he Syst em  and Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 215ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.7Select  the *.tar.gz file, and then click Open.The  Choose File dialog closes and t he nam e of the select ed file displays in t he Upgrades >  Upload page File box.8Click Upload. Wait  for the File has been uploaded m essage t o display.
Updat ing a Pr ism  System  Page 216 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20119I n t he Upload page, Click Browse.1 0 I n t he Choose File dialog, navigat e t o where the upgrade *.tar.gz and *.tar.gz.md5 files are st ored. 1 1 Select  the *.tar.gz.md5 upgrade file, and t hen click Open.1 2 The  Choose File dialog closes and t he nam e of t he selected file displays in the Upgrades >  Upload page File box.1 3 Click Upload. Wait  for the File has been uploaded m essage t o display.UPDATING A PRISM SYSTEMFollow this procedure t o updat e a FlexWave Prism  syst em , or an individual unit  wit hin a FlexWave Prism  syst em .CAUTION! Do not make any configuration changes during an update.CAUTION! This procedure takes the system selected for update temporarily offline (see estimates in Table 25). Perform this procedure during normal maintenance window. NOTE: To update an individual unit, see “Updating Individual Units” on page 221.Do t he following t o update an FlexWave Prism  system :1Access t he Soft ware/ Firm ware report t o verify current  syst em  soft ware.aI n the Syst em  Menu bar, click System Information > Get Information.The System Information > Get Information page opens.bI n t he Type list , select  Software/Firmware. ( This is t he default setting.)Table 25. Estimated Time a System is Offline During an UpgradeSystem Configuration Approximate Time Offline(Minutes)1 Host + 1 Remote Unit 7 - 11 1 Host + 2 Remote Units 10 - 181 Host + 3 Remote Units 15 - 271 Host + 4 Remote Units 21 - 371 Host + 5 Remote Units 28 - 481 Host + 6 Remote Units 37 - 611 Host + 7 Remote Units 48 - 761 Host + 8 Remote Units 60 - 92
Upgrading t he Syst em  and Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 217ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.The Software/Firmware t able provides the following inform at ion:•Module Type—type of unit ( Host, PRU, or URU). •Name—user- assigned nam e for t he unit .•Unit Id—ident ifies the unit  wit hin the syst em  ( see “ Unit  I dent ification”  on page 43) .•Version—version of inst alled soft ware/ firm ware.•Upgrade Status—t he following st at es can be seen. However, wit h t he except ion of Normal operation and Upgraded, the st at es occur very quickly during t he corresponding action and are rarely viewed.–Normal operation –Upgrading –Upgrading reboot –Committing –Aborting –Recovering – Upgraded–NA ( analog units only) . 2Follow the steps in “ Upload t he Upgrade Files”  on page 214 to upload t he required upgrade files.
Updat ing a Pr ism  System  Page 218 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20113Update the Host  and t he Rem ot e Unit(s) :  aI n the Syst em  Menu bar, click Upgrades >  Update Units. I n t he Update Units page, you are not ified t hat  the file t hat  you uploaded in “ Upload t he Upgrade Files”  on page 214 is ready for use. I f an upgrade file is not list ed, repeat t he steps in “ Upload t he Upgrade Files”  on page 214.bI n t he Select Unit Type list , select  Host+DRU+PRU+URU.NOTE: The IFEU + RAU option pertains to an InterReach Spectrum system only and is not applicable to a Prism system. As such, do not select the IFEU + RAU option.cClick  Update Now. An inform ation m essage that  t he updat e has st art ed appears. Wit hin four m inut es, t he EMS logs you off and t erm inat es t he EMS session.
Upgrading t he Syst em  and Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 219ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.CAUTION! At this point, the system goes offline for the approximate time listed in Table 25  on page 216.dWait  approxim at ely four m inutes, and t hen log back in to t he EMS to com plete this procedure.4Com plet e St ep 1 on page 216 t o verify the st atus of the Host / Rem ot e Unit ( s)  updat es.COMMIT THE UPGRADENOTE: If you need to abort an update, go to“Abort an Update” on page 220.1Com plet e t he st eps in “ Updat ing a Prism  Syst em ”  on page 216.2I n the Syst em  Menu bar, click Upgrades >  Commit.3I n t he Upgrades > Commit page, click Commit.4I n t he confirm at ion window, click OK.The syst em  inform s you when the com m it  operation has com pleted.
Abort an Updat e  Page 220 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011ABORT AN UPDATEAn upgrade can be aborted, if necessary. NOTE: If you want to commit an update, go to “Commit the Upgrade” on page 219.1To access the Upgrades Abort page, in t he Syst em  Menu bar, click Upgrades >  Abort.2Click Abort.3I n t he confirm at ion window, click OK.The syst em  inform s you when the abort operat ion has com plet ed.
Upgrading t he Syst em  and Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 221ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.UPDATING INDIVIDUAL UNITSOnly perform  a unit  updat e on a unit  when the unit is being added t o the syst em  as a new or replacem ent unit, and t he new unit  requires a firm ware updat e t o m at ch t he firm ware version of the ot her units wit hin t he syst em .CAUTION! If this procedure is performed on a Host Unit, the Host is taken offline (see estimates in Table 25 on page 216). Perform this procedure during normal maintenance time.CAUTION! Do not make any configuration changes during an update.NOTE: To update a Prism system, follow the steps in “Updating a Prism System” on page 216.Com plet e t he following steps to updat e an individual Host , PRU, or URU:1Access t he Soft ware/ Firm ware report t o verify current  syst em  soft ware.aI n the Syst em  Menu bar, click System Information > Get Information.The System Information > Get Information page opens.bI n t he Type list , select  Software/Firmware. ( This is the default  set t ing.)For inform ation on t he Software/Firmware table, see “ Updat ing a Prism  System ”.2Follow t he steps in “Upload t he Upgrade Files”  on page 214 to upload the required updat e files.3I n the Syst em  Tree, click on t he icon of the unit t hat  you want t o updat e.
Updat ing I ndividual Unit s  Page 222 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 20114I n the Unit  Menu bar, click Unit Upgrades, Upgrade.NOTE: If you have not uploaded the required update files, the following page opens, and the Update button is disabled. You cannot continue until the correct update files have been loaded.5Click Update.Wit hin four m inut es, t he EMS logs you off and t erm inat es t he EMS session. CAUTION! At this point, the system goes offline for the approximate time listed in Table 25  on page 216.6Wait  approxim at ely four m inutes, and then log back in t o the EMS to com plet e this procedure.7Com plet e St ep 1 on page 216 t o verify the st atus of t he updat e. Do not  m ove forward to the next  st ep unt il the UpGrade Status in the Soft ware/ Firm ware table is listed as Upgraded.
Upgrading t he Syst em  and Unit sFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 223ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.8Com m it  the updat e t o t he unit. ( I f you need to abort an updat e, go t o “ Abort an Update”  on page 220.)aI n the Syst em  Menu bar, click Upgrades >  Commit.bI n t he Upgrades > Commit page, click Commit.cI n t he confirm at ion window, click OK.The syst em  inform s you when the com m it  operation has com pleted.9Com plet e St ep 1 on page 216 to verify t he stat us of t he updat e.
Updat ing I ndividual Unit s  Page 224 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011I nt ent ionally Blank Page
FlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 225ADCP- 77- 177  • I ssue 1 • July 2011 © 2011 ADC Telecommunications, Inc.SPECIAL FEATURESRun Script ........................................................................................................................... 226Run Com m and .....................................................................................................................226Configure Feature ................................................................................................................ 227This sect ion describes special features of the Prism  EMS.NOTE: Some of the features in this section are for use by ADC only.Topics Page
Run Scr ipt  Page 226 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011RUN SCRIPTThe  Run Script page, accessed via Special Features > Run Script, is not applicable t o a Prism  syst em  and should not be used.RUN COMMANDThe Run Command page, accessed via Special Features > Run Command, is not  applicable to a Prism  syst em  and should not  be used.
Special Feat uresFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 227ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.CONFIGURE FEATURECAUTION! This procedure requires a system reboot. The system configuration is stored on the Host. Rebooting the Host therefore results in a loss of RF for the Host and connected Remote Units until the Host comes back up. Depending on the system configuration, it can take 5 to 20 minutes before management communication is restored. CAUTION! Host configuration will not persist across a Configure Feature Reboot—all settings will revert to factory default. You will need to reconfigure the Prism system after the system reboots.CAUTION! The current EMS session will close and you will need to log back in to the EMS after the Host reboot has completed.1Docum ent all configuration data, as set tings will have to be re- ent ered. To record t he current  configuration:aFollow the procedures in “ Viewing t he All Report ”  on page 112 to access t he syst em  configurat ion reports.bFollow the procedures in “ Downloading a Report ”  on page 113 t o download the syst em  configuration report s t o a hard drive.2To access the Configure Feature page, in the Syst em  Menu bar, click Special Features >  Configure Feature.3I n t he Feature box, ent er the code for the feature.4I n t he Password box, enter t he password that enables the feat ur e.5Click Apply.6I n t he confirm at ion dialog, click OK.7Log back in to the EMS once t he login window displays.8Follow the st eps in “ I nit ial FlexWave Prism  Syst em  Set up”  on page 55 t o reconfigure t he Prism  syst em , using the set tings recorded in St ep 1 on page 227.
Configure Feat ure  Page 228 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011I nt ent ionally Blank Page
FlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 229ADCP- 77- 177  • I ssue 1 • July 2011 © 2011 ADC Telecommunications, Inc.USING AN SNMP INTERFACESNMP Overview ...................................................................................................................230Working wit h Prism  MI B Files................................................................................................. 231Accessing Prism  MI Bs...................................................................................................... 233Syst em  Dat e and Tim e MI B Form at ................................................................................... 234Band Types ................................................................................................................... 235Prism  MI B Obj ect s................................................................................................................ 236Param eters in ADC- FLEXWAVE- URH-MI B ........................................................................... 237Syst em - Level Param eters .......................................................................................... 237Host  Unit  Param eters ................................................................................................ 239Host  Param eters.................................................................................................. 239Host  SeRF Card Param eters .................................................................................. 240Host  SeRF Optics Param et ers ................................................................................ 243Host  SeRF ENET Swit ch Param et ers ....................................................................... 245Host  SeRF FPGA Param eters ................................................................................. 247Host  List  of Rem ot es Param et ers ........................................................................... 247Host  DART Module Param et er s .............................................................................. 248Host  Syst em  Card Param et ers ............................................................................... 252Rem ot e Unit  Param eters ............................................................................................ 254Rem ot e Param eters ............................................................................................. 254Prism  Rem ot e Syst em  Card................................................................................... 256Prism  Rem ot e SeRF General.................................................................................. 257Prism  Rem ot e SeRF Opt ics.................................................................................... 260Prism  Rem ot e SeRF ENET Swit ch ........................................................................... 262Prism  Rem ot e SeRF FPGA ..................................................................................... 264Prism  Rem ot e DART............................................................................................. 264Prism  Rem ot e LPA ............................................................................................... 270Prism  Rem ot e Power Det ect or ............................................................................... 272Prism  Rem ot e LNA/ Duplexer ................................................................................. 273Prism  Rem ot e RDI  Card ........................................................................................ 274Prism  Rem ot e RSI  Car d ........................................................................................ 275Com m on Managed Obj ect s ......................................................................................... 276Prism  DART Mapping ............................................................................................ 276Schedule Syst em  Link Test ................................................................................... 278SNMP Set tings .................................................................................................... 279Regist er SNMP Trap Manager ................................................................................ 280Geographic Locations ................................................................................................ 281GEO Obj ect s ....................................................................................................... 281GEO Table Obj ect s............................................................................................... 282Managed Obj ect s for Traps ......................................................................................... 283Prism  I nput Cont act  Alarm  Managem ent  Table......................................................... 283Syst em  Act ive Alarm  Table ................................................................................... 284Alarm  Managem ent Table ..................................................................................... 287Alarm  Enable Table .............................................................................................. 288St atic Alarm s Table.............................................................................................. 288Working wit h SNMP Traps ..................................................................................................... 290View the Traps ............................................................................................................... 290Managing Traps.............................................................................................................. 291Dat e and Tim e Stam ps in Tr aps ........................................................................................ 292Variable Bindings............................................................................................................ 293Topics Page
SNMP Overview  Page 230 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011SNMP OVERVIEWSNMP ( Sim ple Net work Managem ent  Protocol)  is an international st andard for rem ot e control of online devices. A t ypical scenario involves t he devices being cont rolled, rem ot e com puters ( called m anagers)  that  can cont rol them , a network connect ion, and SNMP soft ware. The SNMP software includes SNMP m anager soft ware on cont rolling com put ers, SNMP agent  soft ware on m anaged devices, and one or m ore MI Bs used by the SNMP m anagers for each cont rolled device. I n som e cases, SNMP proxy agent software is run on an int erm ediate device t o access a m anaged device t hat would not  ot herwise be directly accessible.The Prism  syst em  SNMP int erface, shown schem at ically in Figure 27 allows a rem ot e user using an SNMP m anager t o access t he sam e dat abase as accessed by the st andard EMS interface.Figure 27. SNMP and a Prism SystemIPIPWebGET/SETTRAPWindows 2000 or Windows XPcomputer runningInternet Explorer or Mozillaand/or SNMP ManagerDatabaseEMSINTERNALNetwork portHost Unit
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 231ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.WORKING WITH PRISM MIB FILESNOTE: Examples shown in this chapter use a browser from AdventNet or iReasoning. Procedural details may vary with another browser, but the basic steps are the same.NOTE: In the Prism system, the database accessed through the SNMP interface is the same database as used by the EMS graphical user interface. There is therefore a similarity between MIB objects and the parameters displayed in the EMS Web pages.Figure 28 shows t he features of a t ypical MI B browser.Figure 28. Typical MIB BrowserAs m entioned earlier, a MI B is a database specificat ion cont aining definitions and organizat ion of inform at ion. The database consist s of tables of obj ect s used t o exchange inform ation between a m anager and agent . Dat abase inform ation is exchanged using the following basic operat ions:  •GET—obt ains an obj ect  value from  t he dat abase.•SET—set s t he value of an obj ect  in the database.•GET-NEXT—get s the next  it em  in the database, be it t he next t ype of obj ect or the next  obj ect  of t he specified t ype. This is especially useful for discovering the presence of ent ries in dynam ic t ables.•GET-BULK—requests m ultiple item s in one m essage.•TRAP/NOTIFICATION—sends an alarm  in which a response can be sent  by a m anager t o an agent confirm ing receipt  of t he alarm .
Wor king wit h Prism  MI B Files  Page 232 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011I n a m anager browser, a MI B looks like t he EMS System  Tree’s hierarchy of folders and files, as shown in Figure 29. Figure 29. Prism MIB TreeMI B it em s are arranged in a hierarchy of groups, like a hierarchy of folders. Known OI Ds specify scalars ( obj ect s) . MI B obj ects are arranged in groups and t ables. To be specified com plet ely, t able entries require one or m ore row indices. Each set  of obj ect s (wit hin a single folder) represents one such group or table. An obj ect m arked wit h a key sym bol indicates that  view is t he key value for t hat  table.The Prism  MI B is defined by t hree files:•ADC-FWU-URH-TC-MIB.mib •ADC-FWU-IRS-TC-MIB.mib •ADC-FLEXWAVE-URH.mib The MI B can be found on t he SeRF I I  card in the Host  in /usr/local/fwu/mibs. “ Prism  MI B Obj ect s”  on page 236 list s object s t hat  m ay be accessed for GET/SEToperations and t raps/ not ificat ions that  are sent t o SNMP m anagers regist ered t o receive t hem  whenever t he respective fault condit ion occurs. NOTE: TRAPS/NOTIFICATIONS are listed with the corresponding EMS alarm in “Troubleshooting Alarms” on page 185.
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 233ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Accessing Prism MIBsThe Prism  Agent  MI B can be accessed using any SNMP m anager wit h an act ive net work connect ion. The I P address of t he Host m ust  be known and ent ered in t he MI B browser.1On t he m anager com puter, open t he MI B Browser. 2Load t he MI B files in the following order:aADC-FWU-URH-TC-MIB.mib bADC-FWU-IRS-TC-MIB.mib cADC-FLEXWAVE-URH.mib 3Ent er t he I P address of t he Host of t he Prism  syst em  in t he t ext box provided next  to Host. 4Enter the Port number as 161.NOTE: If you are upgrading from a previous release, note the change in the SNMP Port number. In previous releases, the SNMP Port number was 8001. It is now 161.5Enter the Read Community as public and Write Community as private.6Set Timeout t o 15 seconds.7For SNMP version v2c and v3, set Maximum Repetitions t o 10 or less.8To see an overview t he MI B cont ent , expand t he MI B t ree, as shown below.
Wor king wit h Prism  MI B Files  Page 234 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011System Date and Time MIB FormatfwuHstSystemDateandTime allows you t o set  the syst em  dat e and tim e, where the input is as follows:YYYY-MM-DD,HH:MM:SS.D (24-Hour Time Format)where fields are required ( none are opt ional)  and indicate the following in 24- Hour tim e form at.•YYYY—Year•MM—Month•DD—dat e•HH—Hour•MM—Min ut e•SS—SecondsYou can input  the m ont h, dat e, hour, m inutes, seconds, and deci seconds as a single digit  or as a double digit ( t hat is, prefixed wit h 0) .The support ed dat e and t im e range is from  1970-01-01,00:00:00 t o 2037-12-31,23:59:59.The out put  for m ont h, dat e, hour, m inutes, and seconds will always be in double digit  form at  (prefixed wit h 0) . The out put  for deci seconds will always be single digit .For exam ple, t he output of 2009-01-02,03:04:05 can be result ant  from  eit her of t he following input s:•I nput  1—2009-01-02,03:04:05•I nput  2—2009-1-2,3:4:5
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 235ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Band TypesTable 26 list s the band t ypes for Host RF DARTs, and Table 27 on page 236 list s the band types for Rem ote I F DARTs.Table 26. MIB Band Types—Host RF DARTSMID Value Band Type-1 undefined 1Classic8502Classic19003ClassicSMR8004ClassicSMR9005ClassicAws21006Classic1800200 SingleSuperPcs1900201 SingleSuper1800202 SingleSuperUmts2100203 SingleSuperAws21008SuperPcs190010 SuperUmts210011 SuperAws210012 SuperEgsm90013 SuperLowerAbc70014 SuperUpperC700205 SingleSuperLowerAbc700206 SingleSuperUpperC700
Prism  MI B Obj ect s  Page 236 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011PRISM MIB OBJECTSObj ect s in the Prism  Agent  MI B divide into t wo t ypes:  GET/SET object s and Trap/ Notificat ion obj ect s.For each GET and SET obj ect , t here is an SNMP synt ax, which is a range of values defined in t he MI B file. These values are what  can be ent ered in a SET com m and and ret urned in a GET com m and.The following sect ions list  all MI B obj ect s wit hin t he Prism  Agent MI B. Obj ect s that are available for SET com m ands are also available for GET com m ands.Table 27. MIB Band Types—Remote IF DARTSMID Value Band Type15 SuperIf85016 SuperIfPcs190017 SuperIfSmr80018 SuperIfSmr90019 SuperIf180021 SuperIfAws210023 SuperIfPath1LowerAbc70024 SuperIfPath1UpperC70025 SuperIfPath2LowerAbc70026 SuperIfPath2UpperC700207 SingleSuperIf850208 SingleSuperIfPcs1900209 SingleSuperIfSmr800210 SingleSuperIfSmr900211 SingleSuperIf1800213 SingleSuperIfAws2100215 SingleSuperIfPath1LowerAbc700 216 SingleSuperIfPath1UpperC700 217 SingleSuperIfPath2LowerAbc700 218 SingleSuperIfPath2UpperC700
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 237ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Parameters in ADC-FLEXWAVE-URH-MIBSystem-Level ParametersSyst em  Dat e  a nd Tim eSNMP MIB: fwuHstSystemDateAndTimeDescription: The dat e and tim e set t ings on t he systemValues: 1970-01- 01,00: 00: 00 to 2037-12-31,23: 59: 59;  see “ Syst em  Date and Tim e MI B Form at” on page 234Default: Syst em  t im eSyntax: Dat eAndTim eAccess Level: Oct et StringSyst em  Ala rm  Ack now ledgeSNMP MIB: fwuSystemAlarmAckDescription: Acknowledges all or individual alarm sValues: 0 =  Acknowledge all alarm sGreat er t hen 0, I d of t he alarm  to be acknowledgedSyntax: I nteger32Access Level: Read- Writ eSyst em  Ala rm  LevelSNMP MIB: fwuAlarmLevelDescription: Alarm  level of syst emSyntax: Alarm TypeAccess Level: Read- Writ eSyst em  Te st  On Pow e r UpSNMP MIB: fwuPwrUpLinkTestDescription: Syst em / Link Test  on Power Up (Link Test )Values: 1 =  Enable0 =  DisableDefault: 0Syntax: Unsigned32Access Level: Read- Writ e
Prism  MI B Obj ect s  Page 238 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011DART Band Type  for  Syst em  Test  User Com m ande dSNMP MIB: fwuUserCommLinkTestDartBandTypeDescription: Band t ype ( t he RF DART type)  of select ed unit sValues: See “ Band Types”  on page 235.Default: 0Syntax: BandTypeAccess Level: Read- Writ eDART I D for  Syst e m  Test  Use r Com m a nde dSNMP MIB: fwuUserCommLinkTestDartIdDescription: I d of a particular DARTValues: 1 -  8Syntax: I nteger32Access Level: Read- Writ e Syst em  Ala rm  St atus Sum m arySNMP MIB: fwuSystemAlarmStatusSummaryDescription: Alarm  St atus Sum m ary for ent ire syst emSyntax: Alarm TypeAccess Level: Read OnlyCle ar Syst em  Configura t ionSNMP MIB: fwuClearSysConfigDescription: Changing t he value from  0 to 1 clears the setting for the entire set t ings on the syst emValues: 0 =  Disable1=  EnableDefault: 0Syntax: I nteger32Access Level: Read- Writ eLast  Run  Tim e  of Syst em / Link TestSNMP MIB: fwuLinkTestLastRunTimeDescription: Tim e when the Syst em / Link test was last  runSyntax: Dat eAndTim eAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 239ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Host Unit ParametersHost ParametersHost  N um berSNMP MIB: fwuHstNumberDescription: Num ber enum erating a HostValues: A num ber great er than 0Default: 1Syntax: I nteger32Access Level: Read OnlyHost  N a m eSNMP MIB: fwuHstNameDescription: User defined nam e of t he Host  Values: Alphanum eric Charact ers. Except  as first  character, t he underscore ( _)  character is allowed. Must  be 5 t o 40 charact ers in length, wit h no spaces.Default: Unknown_Host Nam e Syntax: Display StringAccess Level: Read- Writ eHost  Un it  ResetSNMP MIB: fwuHstUnitResetDescription: Reset s t he Host SeRF card when t he value is changed from  0 t o 1Values: 0=  norm al1 =  resetDefault: 0 Syntax: I ntegerAccess Level: Read- Writ eHost  Back Plane  Re visionSNMP MIB: fwuHstBackPlaneRevDescription: Provides the back plane revision of t he Host  ( Three pin Version Num ber of the Chassis back plane)Values: SI ZE ( 1…40)Syntax: Oct al St ringAccess Level: Read Only
Prism  MI B Obj ect s  Page 240 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Host  Alarm  St a t us Sum m a rySNMP MIB: fwuHstAlarmStatusSummaryDescription: Alarm  St atus Sum m ary for Host  Syntax: ALARM- TYPEAccess Level: Read OnlyTe m pera t ure M ea sure m entSNMP MIB: fwuHstTempMeasDescription: Host syst em  t em perat ure value in CelsiusValues: SI ZE (  1…8)Syntax: Oct al St ringAccess Level: Read OnlyLinking ModeSNMP MIB: fwuHstLinkingModeAccess Level: The DART Linking m ode on t he Syst emValues: 2 =  ManualDefault: 2Syntax: I ntegerAccess Level: Read- Writ eHost SeRF Card ParametersLinux Kernel Ve rsionSNMP MIB: fwuHstSERFLinuxKernelVerDescription: Linux Kernel Version of the Host  systemSyntax: Display StringAccess Level: Read OnlyLinu x Boot  Loader Ver sionSNMP MIB: fwuHstSERFLinuxBootLoaderVerDescription: Version Num ber of t he second st age boot  loaderSyntax: Display StringAccess Level: Read OnlyCom pact  Flash SW  Ver sionSNMP MIB: fwuHstSERFCompactFlashSWVerDescription: Com pact  Flash Version of the Host  syst emValues: Form at  of:  aa.bb.cc.ddwhere each of aa, bb, cc, dd m ust  be bet ween 00 and 99Syntax: Display StringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 241ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.PPC H W  Mon it or SW  Ver sionSNMP MIB: fwuHstSERFPPCHWMonSWVerDescription: Soft ware Version of the hardware Monit or process running on t he HostSyntax: Display StringAccess Level: Read OnlyPPC Application Monit or SW  VersionSNMP MIB: fwuHstSERFPPCAPPMonSWVerDescription: Soft ware Version of the Applicat ion Monit or process running on t he HostSyntax: Display StringAccess Level: Read OnlySN M P Agent  SW  VersionSNMP MIB: fwuHstSERFPPCSNMPAgentSWVerDescription: Soft ware Version of the HTTP/ SNMP agent  running on HostSyntax: Display StringAccess Level: Read OnlyPPC M ate Monit or SW  VersionSNMP MIB: fwuHstSERFPPCMATEMonSWVerDescription: Soft ware Version of the Mat e Monit or process running on the HostUnitSyntax: Display StringAccess Level: Read OnlyPPC EN ET Monit or SW  VersionSNMP MIB: fwuHstSERFPPCENETMonSWVerDescription: Soft ware Version of the Ethernet  Monitor process running on the HostUnitSyntax: Display StringAccess Level: Read OnlyPPC FPGA M onit or SW  VersionSNMP MIB: fwuHstSERFPPCFPGAMonSWVerDescription: Version of FPGA Loaded on SeRFSyntax: Display StringAccess Level: Read Only
Prism  MI B Obj ect s  Page 242 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Linux First  St age Boot  Loader Ve rsionSNMP MIB: fwuHstSERFLinuxBootLoaderVerDescription: Boot  Loader1 Version of the Host  syst emSyntax: Display StringAccess Level: Read OnlySe RF FPGA Ver sionSNMP MIB: fwuHstSERFFPGAVerDescription: Version of FPGA Loaded on SeRFSyntax: Display StringAccess Level: Read OnlyRI  ADC Pa rt N um berSNMP MIB: fwuHstSERFRIADCPartNumberDescription: Host SeRF I nvent ory -  ADC Part Num berSyntax: Display StringAccess Level: Read OnlyRI  Se rial N um berSNMP MIB: fwuHstSERFRISerialNumberDescription: Host SeRF I nventory -  Serial Num berSyntax: Display StringAccess Level: Read OnlyRI  Dat e  CodeSNMP MIB: fwuHstSERFRIDateCodeDescription: Host SeRF I nvent ory -  Dat e CodeSyntax: Display StringAccess Level: Read OnlySe RF RI  H a rdw ar e VersionSNMP MIB: fwuHstSERFRIHWVerDescription: Host SeRF I nventory -  Hardware VersionSyntax: Oct al St ringAccess Level: Read OnlySe RF RI  H a rdw ar e Genera t ionSNMP MIB: fwuHstSERFRIHWGenDescription: Host SeRF Hardware Generat ionValues: 0 =  First  Generat ion1 =  Second Generat ion Syntax: I ntegerAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 243ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.pTh rea d Soft w a re VersionSNMP MIB: fwupThreadSoftwareVersionDescription: The version num ber of pThread processSyntax: DisplaySt ringAccess Level: Read OnlySubagent  Softw ar e VersionSNMP MIB: fwuSubagentSwVersionDescription: The version num ber of t he subagentSyntax: DisplaySt ringAccess Level: Read OnlyW e b Server  Softw are  VersionSNMP MIB: fwuWebServerSwVersionDescription: The version num ber of web serverSyntax: DisplaySt ringAccess Level: Read OnlyHost SeRF Optics ParametersSFP Num be rSNMP MIB: fwuHstSERFOptSFPNumberDescription: SFP Num bers used as I ndex for Opt ical Port sValues: 1 -  8Syntax: I nt eger32 Access Level: Read OnlySFP Nam eSNMP MIB: fwuHstSERFOptSFPNameDescription: User defined SFP nam e - Opt ical Port  Nam eValues: Alphanum eric Charact ers. Except  as first  character, t he underscore ( _)  charact er is allowed. Must be between 5 and 32 characters in lengt h, wit h no spaces.Default: UnknownSFPNam eSyntax: Display StringAccess Level: Read- Writ eSFP TypeSNMP MIB: fwuHstSERFOptSFPTypeDescription: SFP Type - Opt ical Port TypeSyntax: Opt icsTypeAccess Level: Read Only
Prism  MI B Obj ect s  Page 244 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011SFP Transm ission ColorSNMP MIB: fwuHstSERFOptSFPTxColorDescription: SFP wavelengt h in nanom eter ( nm )Syntax: I nteger32Access Level: Read OnlyFW D Launch  Pow e rSNMP MIB: fwuHstSERFOptFwdLaunchPowerMeasDescription: Value of Host  Transm it  m easured opt ical power in dBmSyntax: DisplaySt ringAccess Level: Read OnlyREV Re ceive  Pow erSNMP MIB: fwuHstSERFOptRevLaunchPowerMeasDescription: Value of Host  Receive m easured opt ical power in dBmSyntax: DisplaySt ringAccess Level: Read OnlyMate N am eSNMP MIB: fwuHstSERFOptMateNameDescription: Nam e of Host  Mat esValues: I nherit s the valid values from  Host  Nam eDefault: NASyntax: DisplaySt ringAccess Level: Read OnlyMate I DSNMP MIB: fwuHstSERFOptMateIdDescription: I D ( num erical)  of com panion Rem ot e UnitValues: See “ Unit  I dentificat ion”  on page 43Syntax: NodeAddr1Access Level: Read OnlyMat e SFP I DSNMP MIB: fwuHstSERFOptMateSfpIdDescription: Slot  I D of t he SFP used at  rem ot e endValues: 1 -  8Syntax: I nteger32Access Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 245ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Host SeRF ENET Switch ParametersEt her net  Port  N um berSNMP MIB: fwuHstSERFEthPortNumberDescription: An ident ifier for each Ethernet  portValues: 1…12Syntax: Unsigned32Access Level: Read OnlyEt her net  Port  TypeSNMP MIB: fwuHstSERFEthPortTypeDescription: An ident ifier for t he type of Et hernet portSyntax: Enet TypeAccess Level: Read OnlyHost  SFP I DSNMP MIB: fwuHstSERFEthPortSFPIdDescription: I dent ifier of SFP to which t he Ethernet port connectsValues: 1…8Syntax: I nteger32Access Level: Read OnlyRx - by t e sSNMP MIB: fwuHstSERFEthPortRxBytesDescription: Receive byt e count erSyntax: Count er64Access Level: Read OnlyRx - p ack e t sSNMP MIB: fwuHstSERFEthPortRxPktsDescription: Receive packet  count erSyntax: Count er64Access Level: Read OnlyRx- fsc- e rrorsSNMP MIB: fwuHstSERFEthPortRxFcsErrorsDescription: Receive FCS error count erSyntax: Count er64Access Level: Read Only
Prism  MI B Obj ect s  Page 246 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Re ce iv e- m ult ica st - pa ck et sSNMP MIB: fwuHstSERFEthPortRxMulticastPktsDescription: Receive m ult icast packet counterSyntax: Count er64Access Level: Read OnlyRe ce iv e- br oa dca st - pa ck e t sSNMP MIB: fwuHstSERFEthPortRxBroadcastPktsDescription: Receive broadcast packet counterSyntax: Count er64Access Level: Read OnlyRx- fragm ent ed- fram esSNMP MIB: fwuHstSERFEthPortRxFragmtdFramesDescription: Receive fragm ents count erSyntax: Count er64Access Level: Read OnlyRx- j abber- fram e sSNMP MIB: fwuHstSERFEthPortRxJabbersFramesDescription: Receive jabber count erSyntax: Count er64Access Level: Read OnlyTx - byte- cou nt erSNMP MIB: fwuHstSERFEthPortTxByteCounterDescription: Transm it  byte counterSyntax: Count er64Access Level: Read OnlyTx - pa ck e t sSNMP MIB: fwuHstSERFEthPortTxPktsDescription: Transm it  packet counterSyntax: Count er64Access Level: Read OnlyTx - m ult ica st - pa ck e t sSNMP MIB: fwuHstSERFEthPortTxMulticastPktsDescription: Transm it  m ulticast packet counterSyntax: Count er64Access Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 247ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Tx - br oa dca st - p ack e t sSNMP MIB: fwuHstSERFEthPortTxBroadcastPktsDescription: Transm it  broadcast packet counterSyntax: Count er64Access Level: Read OnlyHost SeRF FPGA ParametersSt a t u sSNMP MIB: fwuHstSERFFPGAStatusDescription: Gives t he st atus if FPGA on SeRF CardValues: 0 =  PPC can t alk t o FPGA1 =  PPC cannot  t alk t o FPGADefault: 0Syntax: I ntegerAccess Level: Read OnlyHost List of Remotes ParametersMonit or I nde xSNMP MIB: fwuHMmonIndexDescription: I ndex of t he Host  m at e m onit or t ableSyntax: I nteger32Access Level: Read OnlyRem ot e  I DSNMP MIB: fwuHMmonRmtIDDescription: I D ( num erical)  of com panion Rem ot e UnitValues: See “ Unit  I dentificat ion”  on page 43Syntax: NodeAddr1Access Level: Read OnlyRem ot e  I P AddressSNMP MIB: fwuHMmonRmtIPAddressDescription: List  of I P addresses of connected Rem ot e Unit ( s)Syntax: I pAddressAccess Level: Read Only
Prism  MI B Obj ect s  Page 248 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Host DART Module ParametersCard N um berSNMP MIB: fwuHstDARTNumberDescription: A unique ident ifier for each DART Module Obj ectValues: Range 1 -  8Syntax: I ntegerAccess Level: Read OnlyCard N am eSNMP MIB: fwuHstDARTNameDescription: A user defined nam e for each DART Module Values: Alphanum eric Charact ers. Except  as first  character, t he underscore ( _)  charact er is allowed. Must be between 5 and 32 charact ers in lengt h, wit h no spaces.Description: Unknown_DARTSyntax: Display StringAccess Level: Read- Writ eBa nd TypeSNMP MIB: fwuHstDARTBandTypeDescription: Band t ype of Host  DART ModuleValues: See “ Band Types”  on page 235.Default: - 1Syntax: BAND- TYPEAccess Level: Read OnlyPa ssbandSNMP MIB: fwuHstDARTPassBandDescription: Passband for t he select ed DARTValues: SI ZE ( 0…40)Default: - 1Syntax: OCTET STRI NG Access Level: Read- Writ eOpe rating ModeSNMP MIB: fwuHstDARTOperatingModeDescription: Operat ing m ode of t he DART ModuleSyntax: ModeTypeAccess Level: Read- Writ e
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 249ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Diversit y St a t usSNMP MIB: fwuHstDARTDiversityStatusDescription: Diversit y St atus of Host  DART ModuleValues: 0 =  Non- diversit y1 =  Diversit yDefault: 0Syntax: I ntegerAccess Level: Read OnlyForw ard GainSNMP MIB: fwuHstDARTForwardGainDescription: Prim ary Gain of Host  DART Module Default: 0Syntax: GainTypeAccess Level: Read- Writ eReverse GainSNMP MIB: fwuHstDARTReverseGainDescription: Prim ary Gain of Host  DART ModuleValues: 5…36, Unit s =  dB, increm ents 1dBDefault: 0Syntax: GainTypeAccess Level: Read- Writ eFPGA St atusSNMP MIB: fwuHstDARTFPGAStatusDescription: Host DART FPGA St at us;  indicat es whet her the SeRF FPGA can talk to t he DART FPGAValues: 0 =  SeRF FPGA can talk t o DART FPGA1 =  SeRF FPGA cannot  talk t o DART FPGADefault: 0Syntax: I ntegerAccess Level: Read OnlyFPGA Pr ogram  Ver sionSNMP MIB: fwuHstDARTFPGAProgramVerDescription: FPGA version on t he DART ModuleSyntax: Display StringAccess Level: Read Only
Prism  MI B Obj ect s  Page 250 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011RI  ADC Pa rt N um berSNMP MIB: fwuHstDARTRIADCPartNumberDescription: Host DART I nventory Dat a -  ADC Part  Num berSyntax: Display StringAccess Level: Read OnlyRI  Se rial N um berSNMP MIB: fwuHstDARTRISerialNumberDescription: Host DART I nventory Dat a -  Serial Num berSyntax: Display StringAccess Level: Read OnlyRI  Dat e  CodeSNMP MIB: fwuHstDARTRIDateCodeDescription: Host  DART I nventory Data CodeSyntax: Display StringAccess Level: Read OnlyDART RI  H W  Ve rsionSNMP MIB: fwuHstDARTRIHWVerDescription: Host DART I nventory Dat a -  HW VersionSyntax: Display StringAccess Level: Read OnlyRow  St a t usSNMP MIB: fwuHstDARTRowStatusDescription: The st atus of t his concept ual rowSyntax: Row St at u sAccess Level: Read- Cr eat ePe ak Avera ge  I npu t  Pow er Level 1SNMP MIB: fwuHstDARTPeakInputPwrLvl1Description: Peak Average input  Power Level1. For Diversit y syst em s, this will be NA.Default: NASyntax: DisplaySt ringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 251ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Pe ak Avera ge  I nput  Pow er Level 2SNMP MIB: fwuHstDARTPeakInputPwrLvl2Description: Peak Average input Power level2. For Diversit y system s, this will be NA.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyMin Avera ge  I nput Pow e r Le ve l 1SNMP MIB: fwuHstDARTPeakAvgInputPwrLvl1Description: Minim um  Average I nput  Power Level1. For Diversity syst em s, t his will be NA.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyMin Avera ge  I nput Pow e r Le ve l 2SNMP MIB: fwuHstDARTPeakAvgInputPwrLvl2Description: Minim um  Average I nput  Power Level2. For Diversity syst em s, t his will be NA.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyPe ak I nput Pow e r Level 1SNMP MIB: fwuHstDARTMinAvgInputPwrLvl1Description: Peak I nput  Power Level2. For Diversit y system s, this will be NA.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyPe ak I nput Pow e r Level 2SNMP MIB: fwuHstDARTMinAvgInputPwrLvl2Description: Peak I nput  Power Level2. For Diversit y system s, this will be NA.Default: NASyntax: DisplaySt ringAccess Level: Read Only
Prism  MI B Obj ect s  Page 252 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Pow e r Level M odeSNMP MIB: fwuHstDARTInputPowerModeDescription: DART power level ModeValues: 0 =  snapshot 1 =  m axHoldDefault: 0Syntax: I ntegerAccess Level: Read- Writ ePow e r Level Max Hold Re setSNMP MIB: fwuHstDARTPwrLevelMaxHoldResetDescription: Host DART I nput  Power Level Max Hold Reset  Values: - 1 =  Not Applicable0 =  Norm al1 =  ResetDefault: - 1Syntax: I ntegerAccess Level: Read- Writ eLast  M a x  H old Reset Tim eSNMP MIB: fwuHstDARTLastMaxHoldResetTimeDescription: Dat e and Tim e of the last  m axHold reset t im e of the Host  DARTSyntax: Dat eAndTim eAccess Level: Read OnlyI de ntify RF Sour ceSNMP MIB: fwuHstDARTInputSrcDescription: I dent ifies whether t he connect ion is to BTS/ BDAValues: 1 =  BTS2 =  BDADefault: 1Syntax: I ntegerAccess Level: Read- Writ eHost System Card ParametersRI  ADC Pa rt N um berSNMP MIB: fwuHstSysCardRIADCPartNumberDescription: Rm t I nventory Dat a -  ADC Part Num berSyntax: Display StringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 253ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.RI  Se rial N um berSNMP MIB: fwuHstSysCardRISerialNumberDescription: Rm t I nventory Dat a -  Serial Num berSyntax: Display StringAccess Level: Read OnlyRI  Dat e  CodeSNMP MIB: fwuHstSysCardRIDateCodeDescription: Rm t I nventory Dat a -  Dat e CodeSyntax: Display StringAccess Level: Read OnlyRI  HW  VersionSNMP MIB: fwuHstSysCardRIHWVerDescription: Rm t I nventory Dat a -  Hardware VersionSyntax: Display StringAccess Level: Read Only1 0  M H z Refer ence  ClockSNMP MIB: fwuHstSysCard10MhzRefClockDescription: Syst em  Card Reference clockValues: 0- I nt er nal1-ext ernal ref clockDefault: 0Syntax: I ntegerAccess Level: Read- Writ eClock Pr iorit y Le velSNMP MIB: fwuHstSysCardCPLevelDescription: Syst em  card m ast er clock priorit y level Values: 1…14Default: 14Syntax: I nteger32Access Level: Read- Writ e
Prism  MI B Obj ect s  Page 254 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ou t put Refer ence  ClockSNMP MIB: fwuHstSysCardOutputRefClockDescription: Syst em  Card Reference clock. Syst em  Module support s only 10 MHz and Syst em  Board I I  support s bot h 10 MHz and 30 MHz Clock out put .Values: 0 =  Off1 =  10 MHz clock2 =  30 MHz clockDefault: 1 for Host2 for I F Rem ot eSyntax: I ntegerAccess Level: Read- Writ eRI  Hardw are Genera t ionSNMP MIB: fwuHstSysCardRIHWGenDescription: Host Syst em  Card Hardware Generat ionValues: 0 =  First  Generat ion1 =  Second Generat ionDefault: 1Syntax: I ntegerAccess Level: Read OnlyRemote Unit ParametersRemote ParametersN um b erSNMP MIB: fwuRmtNumberDescription: Num ber of the connected Rem ot e Unit .Values: See “ Unit  I dentificat ion”  on page 43Syntax: UnitI d2Access Level: Read OnlyN a m eSNMP MIB: fwuRmtNameDescription: User defined nam e of the Rem ot e Unit .Values: Alphanum eric Charact ers. Except  as first  character, t he underscore ( _)  charact er is allowed. Must be between 5 and 40 charact ers in lengt h, wit h no spaces.Syntax: Display StringAccess Level: Read- Writ e
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 255ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Ala rm  St a t us Sum m arySNMP MIB: fwuRmtAlarmStatusSummaryDescription: Sum m ary of alarm  stat us of t he ( connect ed)  Rem ot e Unit .Syntax: Alarm TypeAccess Level: Read OnlyTypeSNMP MIB: fwuRmtTypeDescription: Type of Rem ot e. Syntax: unit TypeAccess Level: Read OnlyTe m pera t ure M ea sure m entSNMP MIB: fwuRmtTempMeasurementDescription: Tem perat ure of each Rem ot e Unit  in celsius. Syntax: Oct al St ringAccess Level: Read OnlyPr ism  Un it  Reset SNMP MIB: fwuPrismUnitResetDescription: Boolean. Way t o reset t he Rem ot e Unit  rem ot ely. Only applicable to URH Rem ot e Unit s ( URUs).Values: 0 =  Norm al1 =  ResetDefault: Default :  0Syntax: I ntegerAccess Level: Read- Writ eCat alog St at eSNMP MIB: fwuRmtCatalogStateDescription: Cat alog st at e of Rem ot e Unit . Values: This is used in the Recovery of t he Rem ot e UnitSyntax: Cat alogTypeAccess Level: Read OnlyTa ble  Row  St a t usSNMP MIB: fwuRmtGeneralTableRowStatusDescription: The st atus of t his concept ual row.Syntax: RowSt atusAccess Level: Read- Cr eat e
Prism  MI B Obj ect s  Page 256 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011DART I d SNMP MIB: fwuUsrCommLinkTestDartIdDescription: To ident ify the DART Values: 1 -  8Syntax: Unsigned32Access Level: Read- Writ ePrism Remote System CardRI  ADC Pa rt N um berSNMP MIB: fwuRmtSysCardRIADCPartNumberDescription: Rem ot e Unit  I nvent ory Dat a:  ADC Part Num ber.Syntax: Display StringAccess Level: Read OnlyRI  Se rial N um berSNMP MIB: fwuRmtSysCardRISerialNumberDescription: Rem ot e Unit  I nvent ory Data:  Serial Num berSyntax: Display StringAccess Level: Read OnlyRI  Dat e  CodeSNMP MIB: fwuRmtSysCardRIDateCodeDescription: Rem ot e Unit  I nvent ory Data:  Dat eCode Num berSyntax: Display StringAccess Level: Read OnlyRI  Hardw are Ve rsionSNMP MIB: fwuRmtSysCardRIHWVersionDescription: Rm t I nventory Dat a -  Hardware Num berSyntax: Display StringAccess Level: Read Only1 0  M hz Re fere nce  ClockSNMP MIB: fwuRmtSysCard10MhzRefClockDescription: Rem ot e System  Card Reference clock. I t can be internal or ext ernal.Values: 0- I nt ernal1-ext ernal ref clockDescription: 0Syntax: I ntegerAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 257ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Ou t put Refer ence  ClockSNMP MIB: fwuRmtSysCardOutputRefClockDescription: Rem ot e System  Card Reference clock. System  Board support s only 10 MHz and Syst em  Board I I  support s bot h 10 MHz and 30 MHz Clock out putValues: 0 -  off1 -  clock10m hz2 -  clock30m hz Default: 2 Syntax: I ntegerAccess Level: Read- Writ eRI  Hardw are GenSNMP MIB: fwuRmtSysCardRIHWGenDescription: Rem ot e Syst em  Card Hardware GenerationValues: First  Generation =  0Second Generat ion =  1Syntax: I ntegerAccess Level: Read OnlyPrism Remote SeRF GeneralLinux Kernel Ve rsionSNMP MIB: fwuRmtSERFLinuxKernelVerDescription: Linux Kernel Version of the rem ote syst em .Syntax: Display StringAccess Level: Read OnlyLinux  Boot Loader  VersionSNMP MIB: fwuRmtSERFLinuxBootLoaderVerDescription: Linux Boot loader Version of the rem ot e syst em .Syntax: Display StringAccess Level: Read OnlyLinux First St a ge  Boot  Loader Ver sionSNMP MIB: fwuRmtSERFLinuxBootLoaderVerDescription: Boot  Loader1 Version of t he host  syst em .Syntax: Display StringAccess Level: Read Only
Prism  MI B Obj ect s  Page 258 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Com pact  Flash SW  Ver sionSNMP MIB: fwuRmtSERFCompactFlashSWVerDescription: Com pact  Flash Software Version of t he rem ot e syst em .Values: Form at  of:  aa.bb.cc.ddwhere each of aa, bb, cc, dd m ust  be bet ween 00 and 99Syntax: Display StringAccess Level: Read OnlyPPC H W  Mon it or SW  Ver sionSNMP MIB: fwuRmtSERFPPCHWMonSWVerDescription: Hardware m onit or process  Soft ware Version of t he rem ot e system .Syntax: Display StringAccess Level: Read OnlyPPC Application Monit or SW  VersionSNMP MIB: fwuRmtSERFPPCAPPMonSWVerDescription: Applicat ion m onit or process  Software Version of the rem ot e syst em .Syntax: Display StringAccess Level: Read OnlyPPC Agent  SW  Ver sionSNMP MIB: fwuRmtSERFPPCSNMPAgentSWVerDescription: SNMP agent   Soft ware Version of t he rem ot e system .Syntax: Display StringAccess Level: Read OnlyPPC M ate Monit or SW  VersionSNMP MIB: fwuRmtSERFPPCMATEMonSWVerDescription: Mate m onit or process  Soft ware Version of t he rem ot e syst em .Syntax: Display StringAccess Level: Read OnlyPPC EN ET Monit or SW  VersionSNMP MIB: fwuRmtSERFPPCENETMonSWVerDescription: ENET m onit or process  Soft ware Version of t he rem ot e syst em .Syntax: Display StringAccess Level: Read OnlyPPC FPGA M onit or SW  VersionSNMP MIB: fwuRmtSERFPPCFPGAMonSWVerDescription: FPGA m onit or process Soft ware Version of the rem ot e syst em .Syntax: Display StringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 259ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Se RF FPGA Ver sionSNMP MIB: fwuRmtSERFFPGAVerSyntax: Display StringAccess Level: Read OnlyRI  ADC Pa rt N um berSNMP MIB: fwuRmtSERFRIADCPartNumberDescription: Rem ot e SeRF I nventory -   ADC Part  Num ber.Syntax: Display StringAccess Level: Read OnlypTh rea d Soft w a re VersionSNMP MIB: fwuRmtpThreadSoftwareVerDescription: The version num ber of pThread process.Syntax: DisplaySt ringAccess Level: Read OnlyW e b Server  Softw are  VersionSNMP MIB: fwuRmtWebServerSwVerDescription: The version num ber of web server.Syntax: DisplaySt ringAccess Level: Read OnlyRI  Hardw are Ve rsionSNMP MIB: fwuRmtSERFPPCHWMonSWVerDescription: Hardware m onit or process  Software Ver sion of the rem ot e system .Syntax: DisplaySt ringAccess Level: Read OnlyRI  Hardw are SNMP MIB: fwuRmtSERFRIHWGenDescription: Rem ot e SeRF Hardware Generat ion.Values: First  Generation =  0Second Generat ion =  1Syntax: I ntegerAccess Level: Read Only
Prism  MI B Obj ect s  Page 260 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Prism Remote SeRF OpticsOpt ics N um berSNMP MIB: fwuRmtSERFOptSFPNumberDescription: A unique ident ifier of each SFPValues: 1 -  8Syntax: I ntegerAccess Level: Read OnlyOpt ics N a m eSNMP MIB: fwuRmtSERFOptSFPNameDescription: User defined nam e of each Rem ot e SFP.Values: Alphanum eric Charact ers. Except  as first  character, t he underscore ( _) character is allowed. Must be bet ween 5 and 32 charact ers wit h no spaces. Syntax: Display StringAccess Level: Read-  Writ eOpt ics TypeSNMP MIB: fwuRmtSERFOptSFPTypeDescription: SFP Type - Opt ical Port Type.Syntax: Opt icsTypeAccess Level: Read OnlyOpt ics ColorSNMP MIB: fwuRmtSERFOptSFPColorDescription: SFP wavelengt h in nanom eter.Values: I nteger32Syntax: Read OnlyREV La un ch Pow e rSNMP MIB: fwuRmtSERFOptRevLaunchPowerMeasDescription: Value of Rem ote Receive m easured optical power in dbm  .Syntax: Display StringAccess Level: Read OnlyForw ard Receive Pow e rSNMP MIB: fwuRmtSERFOptFwdLaunchPowerMeasDescription: Value of Rem ote Transm it  m easured opt ical power in dbm .Syntax: Display StringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 261ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Mate N am e SNMP MIB: fwuRmtSERFOptMateNameDescription: Nam e of Rem ote m at e.Values: I nherit s valid values from  Rem ot e nam e Syntax: DisplaySt ringAccess Level: Read OnlyMate Unit  I DSNMP MIB: fwuRmtSERFOptMateIdDescription: Num erical I D of com panion Rem ot e Unit .Values: See “ Unit  I dentificat ion”  on page 43Syntax: NodeAddr1Access Level: Read OnlyMate Unit  SFP I DSNMP MIB: fwuRmtSERFOptMateSfpIdDescription: I dent ifier of SFP to which t he m at e connects .Values: 1 -  8Syntax: I nteger32Access Level: Read OnlyMode  SNMP MIB: fwuRmtSERFIPEnableDescription: Mode of I P enable RF carrier.Values: 1=  I PEnable 2 =  I P DisableDefault: 2Syntax: I ntegerAccess Level: Read-  Writ eSFP Dire ct ionSNMP MIB: fwuRmtSERFOptMateSfpDirDescription: I ndicat es whet her t he fiber is incom ing or out going on this SFP port .Values: - 1 =  Unknown0 =  I n1 =  OutSyntax: I ntegerAccess Level: Read Only
Prism  MI B Obj ect s  Page 262 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Prism Remote SeRF ENET SwitchEt her net  Port  N um berSNMP MIB: fwuRmtSERFEthPortNumberDescription: A unique ident ifier for each Et hernet  port.Values: Port num ber, which can be bet ween 1 and 12 Syntax: Unsigned32Access Level: Read OnlyEt her net  Port  TypeSNMP MIB: fwuRmtSERFEthPortTypeDescription: An ident ifier for t he t ype of Ethernet  port .Values: Port t ype: Net work port Craft port Managem ent portSwit ch portSyntax: ENET- TYPEAccess Level: Read OnlyEt her net  SFP I dSNMP MIB: fwuRmtSERFEthSFPIDDescription: I dent ifier of SFP t o which this et hernet  port connects to.Syntax: I nteger32Access Level: Read OnlyRx - by t e sSNMP MIB: fwuRmtSERFEthPortRxBytesDescription: Receive byt e count er.Syntax: Count er64Access Level: Read OnlyRx - p ack e t sSNMP MIB: fwuRmtSERFEthPortRxPktsDescription: Receive packet  counter.Syntax: Count er64Access Level: Read OnlyRx- fsc- e rrorsSNMP MIB: fwuRmtSERFEthPortRxFscErrorsDescription: Receive FCS error count er.Syntax: Count er64Access Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 263ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Re ce iv e- m ult ica st - pa ck e t sSNMP MIB: fwuRmtSERFEthPortRxMulticastPktsDescription: Receive m ult icast  packet counter.Syntax: Count er64Access Level: Read OnlyRe ce iv e - br oa dca st - pa ck e t sSNMP MIB: fwuRmtSERFEthPortRxBroadcastPktsDescription: Receive broadcast packet  counter.Syntax: Count er64Access Level: Read OnlyRx- fragm ent ed- fram esSNMP MIB: fwuRmtSERFEthPortRxFragmtdFramesDescription: Receive fragm ents counter.Syntax: Count er64Access Level: Read OnlyRx- j abber- fr am e sSNMP MIB: fwuRmtSERFEthPortRxJabbersFramesDescription: Receive j abber count er.Syntax: Count er64Access Level: Read OnlyTx - byte- cou nt erSNMP MIB: fwuRmtSERFEthPortTxByteCounterDescription: Transm it  byte counterSyntax: Count er64Access Level: Read OnlyTx - pa ck e t sSNMP MIB: fwuRmtSERFEthPortTxPktsDescription: Transm it  packet counterSyntax: Count er64Access Level: Read OnlyTx - m ult ica st - pa ck e t sSNMP MIB: fwuRmtSERFEthPortTxMulticastPktDescription: Transm it m ult icast  packet  counterSyntax: Count er64Access Level: Read Only
Prism  MI B Obj ect s  Page 264 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Tx - br oa dca st - p ack e t sSNMP MIB: fwuRmtSERFEthPortTxBroadcastPktsDescription: Transm it  broadcast packet counterSyntax: Count er64Access Level: Read OnlyPrism Remote SeRF FPGAFPGA St atusSNMP MIB: fwuRmtSERFFPGAStatusDescription: Rem ot e SeRF Card FPGA st at us.Values: 0 =  PPC can t alk t o FPGA1=  PPC cannot  talk to FPGADefault: 0Syntax: I ntegerAccess Level: Read OnlyPrism Remote DARTCard N um berSNMP MIB: fwuRmtDARTNumberDescription: A unique ident ifier for each DART Module Obj ect .Values: 1 -  8Syntax: Unsigned32Access Level: Read OnlyN a m eSNMP MIB: fwuRmtDARTNameDescription: A user defined nam e for each DART Module. Values: Alphanum eric Charact ers. Except  as first  character, t he underscore ( _)  charact er is allowed. Must be between 5 and 32 charact ers in lengt h, wit h no spaces. Default: Unknown_DARTSyntax: DisplaySt ringAccess Level: Read- Writ eBa nd TypeSNMP MIB: fwuRmtDARTBandTypeDescription: Band t ype of t he Host  DARTValues: See “ Band Types”  on page 235.Default: - 1Syntax: BandTypeAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 265ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Pa ssbandSNMP MIB: fwuRmtDARTPassBandDescription: Passband for the select ed DARTValues: Size of t he passband, which can be bet ween 0 and 40Default: - 1Syntax: Oct et StringAccess Level: Read- Writ eOpe rating ModeSNMP MIB: fwuRmtDARTOperatingModeDescription: Operat ing m ode of t he DART Module.Default: 1Syntax: ModeTypeAccess Level: Read- Writ eDiversit y St a t usSNMP MIB: fwuRmtDARTDiversityStatusDescription: Diversit y St atus of Host  DART Module.Values: 1 =  Diversit y 0 =  Non- diversit yDefault: 0Syntax: I ntegerAccess Level: Read- Writ eForw ard GainSNMP MIB: fwuRmtDARTForwardGainDescription: Prim ary Gain in forward path of Rem ot e Unit  DART Module.Default: 0Syntax: GainTypeAccess Level: Read- Writ eReverse GainSNMP MIB: fwuRmtDARTReverseGainDescription: Prim ary Gain in reverse pat h of Rem ot e Unit  DART Module.Default: 0Syntax: GainTypeAccess Level: Read OnlyForw ard Dela ySNMP MIB: fwuRmtDARTForwardDelayDescription: Rem ot e DART Module forward delay in Micro Seconds.Syntax: DelayTypeAccess Level: Read- Writ e
Prism  MI B Obj ect s  Page 266 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Reverse Dela ySNMP MIB: fwuRmtDARTReverseDelayDescription: Rem ot e DART Module reverse delay in Micro SecondsSyntax: DelayTypeAccess Level: Read- Writ eFPGA Pr ogram  Ver sionSNMP MIB: fwuRmtDARTFPGAProgramVerDescription: FPGA Version on t he Rem ot e Unit  DART Module.Syntax: DisplaySt ringAccess Level: Read OnlyFPGA St atusSNMP MIB: fwuRmtDARTFPGAStatusDescription: Rem ot e DART FPGA St at us. I t indicat es if t he SeRF FPGA can talk t o DART FPGA or not .Values: 0 =  SeRF FPGA can talk t o DART FPGA1 =  SeRF FPGA  cannot t alk t o DART FPGADefault: 0Syntax: I ntegerAccess Level: Read OnlyTe m pera t ure M ea sure m entSNMP MIB: fwuRmtDARTTempMeasDescription: Tem perat ure of Rem ot e DART Module.Syntax: DisplaySt ringAccess Level: Read OnlyADC Pa rt N um berSNMP MIB: fwuRmtDARTRIADCPartNumberDescription: Rem ot e DART I nventory Data -  ADC Part  Num ber.Syntax: Display  St ringAccess Level: Read OnlySe rial N um berSNMP MIB: fwuRmtDARTRISerialNumberDescription: Rem ot e DART I nventory Data -  Serial Num ber.Syntax: Display  St ringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 267ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Dat e  CodeSNMP MIB: fwuRmtDARTRIDateCodeDescription: Rem ot e DART I nventory Dat a -  Dat eCode.Syntax: Display StringAccess Level: Read OnlyRI  Hardw are Ve rsionSNMP MIB: fwuRmtDARTRIHWVerDescription: Rem ot e DART I nventory Dat a -  HW Version.Syntax: Display StringAccess Level: Read OnlyTa ble  Row  St a t usSNMP MIB: fwuRmtDARTGeneralTableRowStatusDescription: The st atus of t his concept ual row.Syntax: RowSt atusAccess Level: Read- Cr eat eAct ual Forw ard De la ySNMP MIB: fwuRmtDARTActualForwardDelayDescription: Act ual value of Forward delay for Rem ot e DART.Syntax: I nteger32Access Level: Read OnlyForw ard Dela y -  Low er  BoundSNMP MIB: fwuRmtDARTForwardLowerboundDelayDescription: Lower bound of Forward delay for Rem ot e DARTSyntax: I nteger32Access Level: Read OnlyForw ard Dela y -  Uppe r BoundSNMP MIB: fwuRmtDARTForwardUpperboundDelayDescription: Upper bound of Forward delay for Rem ot e DART.Syntax: I nteger32Access Level: Read OnlyRem ot e  D ART Act ual Re ve rse Dela ySNMP MIB: fwuRmtDARTActualReverseDelayDescription: Reverse delay for Rem ot e DART.Syntax: I nteger32Access Level: Read Only
Prism  MI B Obj ect s  Page 268 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Reverse Dela y -  Low er  BoundSNMP MIB: fwuRmtDARTReverseLowerboundDelayDescription: Lower bound of Reverse delay for Rem ot e DARTSyntax: I nteger32Access Level: Read OnlyReverse Dela y -  Uppe r BoundSNMP MIB: fwuRmtDARTReverseUpperboundDelayDescription: Upper bound of Reverse delay for Rem ot e DARTSyntax: I nteger32Access Level: Read OnlyPe ak I nput Pow e r Level1SNMP MIB: fwuRmtDARTPeakInputPwrLvl1Description: Peak I nput  Power Level1 t o a Rem ote DART.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyPe ak I nput Pow e r Level2SNMP MIB: fwuRmtDARTPeakInputPwrLvl2Description: Peak I nput  Power Level2 t o a Rem ote DART.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyPe ak Avera ge  I npu t  Pow er Level 1SNMP MIB: fwuRmtDARTPeakAvgInputPwrLvl1Description: Peak Average I nput Power Level1 t o a Rem ot e DART.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyPe ak Avera ge  I npu t  Pow er Level 2SNMP MIB: fwuRmtDARTPeakAvgInputPwrLvl2Description: Peak Average I nput Power Level2 t o a Rem ot e DART.Default: NASyntax: DisplaySt ringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 269ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Minim um  Ave rage I nput  Pow er Le ve l 1SNMP MIB: fwuRmtDARTMinAvgInputPwrLvl1Description: Minim um  Average I nput  Power Level1 t o a Rem ot e DART.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyMinim um  Ave rage I nput  Pow er Le ve l 2SNMP MIB: fwuRmtDARTMinAvgInputPwrLvl2Description: Minim um  Average I nput  Power Level2 t o a Rem ot e DART.Default: NASyntax: DisplaySt ringAccess Level: Read OnlyPow e r Level M odeSNMP MIB: fwuRmtDARTInputPowerModeDescription: Rem ot e DART I nput  Power Level Mode.Values: 0 =  Snap Shot 1 =  Max Hold Default: 0Syntax: I ntegerAccess Level: Read- Writ ePow e r Level Max Hold ResetSNMP MIB: fwuRmtDARTPwrLevelMaxHoldResetDescription: Reset s t he Power Level Max HoldValues: - 1 =  Not Applicable0 =  norm al1 =  reset  Default: - 1Syntax: I ntegerAccess Level: Read- Writ eLast  M a x  H old Reset Tim eSNMP MIB: fwuRmtDARTLastMaxHoldResetTimeDescription: Dat e and Tim e of the last  m axHold reset t im e of Rem ot e.Syntax: DisplaySt ringAccess Level: Read Only
Prism  MI B Obj ect s  Page 270 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Reverse Pa t h Gain M odeSNMP MIB: fwuRmtDARTReverseGainModeDescription: To cont rol gain m ode on t he Reverse Pat h. Applicable t o both Classic and Super DARTs.Values: 0 -  Norm al1 -  HighDefault: 0Syntax: I ntegerAccess Level: Read- Writ ePrism Remote LPALPA N um berSNMP MIB: fwuRmtLPANumberDescription: A unique identifier for an LPA.Values: 1 -  4Syntax: Unsigned32Access Level: Read OnlyLPA ResetSNMP MIB: fwuRmtLPAResetDescription: Set t his object  t o a value of 1 t o cause LPA to reset  it self. Values: 0 =  norm al1 =  resetDefault: 0Syntax: I ntegerAccess Level: Read- Writ eOpe rating ModeSNMP MIB: fwuRmtLPAOpStateDescription: The operating m odes of Rem ot e Unit  LPAValues: 0 =  Operat ing1 =  OfflineDefault: 1Syntax: I ntegerAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 271ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.LPA Cont rolSNMP MIB: fwuRmtLPAControlDescription: To control t he operat ing m ode of Rem ot e Unit  LPA.Values: 0 =  Norm al1 =  St andbyDefault: 1Syntax: I ntegerAccess Level: Read- Writ eMode l N um berSNMP MIB: fwuRmtLPAPartNumDescription: Rem ot e LPA Part  Num ber.Syntax: DisplaySt ringAccess Level: Read OnlySe rial N um berSNMP MIB: fwuRmtLPASerialNumDescription: Rem ot e LPA Serial Num ber.Syntax: DisplaySt ringAccess Level: Read OnlyHar dw are VersionSNMP MIB: fwuRmtLPAHWVerDescription: Rem ot e LPA Hardware Version.Syntax: DisplaySt ringAccess Level: Read OnlySoft w are VersionSNMP MIB: fwuRmtLPASWVerDescription: Rem ot e LPA Soft ware Version.Syntax: DisplaySt ringAccess Level: Read OnlyD escr ip t ionSNMP MIB: fwuRmtLPADescrDescription: Band t ype of Rem ot e LPA Syntax: DisplaySt ringAccess Level: Read Only
Prism  MI B Obj ect s  Page 272 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Prism Remote Power DetectorPow e r De t ect or N um berSNMP MIB: fwuRmtPowerDetectorNumberDescription: I ndex and a unique ident ifier for each power detector.Values: 1 -  4Syntax: I nteger32Access Level: Read OnlyRF Pow e r Output  Mea surem entSNMP MIB: fwuRmtRFPowerOutputMeasDescription: The value of Rem ot e RF Power Output in dBmValues: Up t o 5 charactersSyntax: Oct et  St ringAccess Level: Read OnlyDuple x er RI  Se rial N um berSNMP MIB: fwuRmtPwrDetectorBoardRISerialNumDescription: Power Det ect or I nvent ory -  Serial Num ber.Syntax: DisplaySt ringAccess Level: Read OnlyDuple x er RI  Da t e  CodeSNMP MIB: fwuRmtPwrDetectorBoardRIDateCodeDescription: Power Det ect or I nvent ory -  Date Code.Syntax: DisplaySt ringAccess Level: Read OnlyDuple xer  RI  H a rdw are  VersionSNMP MIB: fwuRmtPwrDetectorBoardRIHWVerDescription: Power Det ector I nvent ory -  HW Version.Values: Up t o 8 Charact ersSyntax: Oct et  St ringAccess Level: Read OnlyDuple x er RI  ADC Pa rt  N um berSNMP MIB: fwuRmtPwrDetectorBoardRIADCPartNumDescription: Power Det ector I nvent ory -  ADC Part Num ber.Syntax: DisplaySt ringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 273ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Syst em  VSW R Mea sure m entSNMP MIB: fwuRmtSystemVswrMeasDescription: Measured VSWR valueValues: Up t o 8 Charact ersSyntax: Oct et StringAccess Level: Read OnlyPrism Remote LNA/DuplexerLN A N um be rSNMP MIB: fwuRmtLNANumberDescription: I ndex and an unique ident ifier for LNA Object s.Values: Num ber that  identifies an LNA and that can be from  1 to 8Syntax: I nteger32Access Level: Read OnlyLN A TypeSNMP MIB: fwuRmtLNATypeDescription: Rem ot e LNA card t ype. Syntax: LnaTypeAccess Level: Read OnlyRI  ADC Pa rt N um berSNMP MIB: fwuRmtLNARIADCPartNumberDescription: LNA I nventory Data - ADC Part  Num ber.Syntax: Display StringAccess Level: Read OnlyRI  Se rial N um berSNMP MIB: fwuRmtLNARISerialNumberDescription: LNA I nventory Dat a -  Serial Num ber.Syntax: Display String Access Level: Read OnlyRI  Dat e  CodeSNMP MIB: fwuRmtLNARIDateCodeDescription: LNA I nventory Data - Date Code.Syntax: Display StringAccess Level: Read Only
Prism  MI B Obj ect s  Page 274 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011RI  Hardw are Ve rsionSNMP MIB: fwuRmtLNARIHWVerDescription: LNA I nventory Data - HW Version.Syntax: DisplaySt ringAccess Level: Read OnlyDuple x er  t ypeSNMP MIB: fwuRmtDuplexerTypeDescription: Duplexer hardware t ype.Syntax: DuplexerTypeAccess Level: Read OnlyPrism Remote RDI CardRDI  N u m berSNMP MIB: fwuRmtRDINumberDescription: I ndex and an ident ifier for each RDI .Values: Num ber that  ident ifies an RDI  and t hat  can be from  1 to 4Syntax: Unsigned32Access Level: Read OnlyRI  ADC Pa rt N um berSNMP MIB: fwuRmtRDIRIADCPartNumberDescription: RDI  I nventory Dat a - ADC Part  Num ber.Syntax: Display StringAccess Level: Read OnlyRI  Se rial N um berSNMP MIB: fwuRmtRDIRISerialNumberDescription: RDI  I nventory Dat a - Serial Num ber.Syntax: Display StringAccess Level: Read OnlyRI  Dat e CodeSNMP MIB: fwuRmtRDIRIDateCodeDescription: RDI  I nventory Dat a - Dat e Code.Syntax: DisplaySt ringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 275ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.RI  Hardw are Ve rsionSNMP MIB: fwuRmtRDIRIHWVerDescription: RDI  I nventory Dat a - HW Version.Syntax: Display StringAccess Level: Read OnlyPrism Remote RSI CardRI  ADC Pa rt N um berSNMP MIB: fwuRmtRSIRIADCPartNumberDescription: Rem ot e I nventory Data -  ADC Part Num ber.Syntax: Display StringAccess Level: Read OnlySe rial N um berSNMP MIB: fwuRmtRSIRISerialNumberDescription: Rem ot e I nventory Data -  Serial Num ber.Syntax: Display StringAccess Level: Read OnlyDat e  CodeSNMP MIB: fwuRmtRSIRIDateCodeDescription: Rem ot e I nventory Data -  Dat e Code.Syntax: DisplaySt ringAccess Level: Read OnlyRI  Hardw are Ve rsionSNMP MIB: fwuRmtRSIRIHWVerDescription: Rem ot e I nventory Data -  Hardware Version.Syntax: Display StringAccess Level: Read OnlyRem ot e  Ca pa cit ySNMP MIB: fwuRmtCapacityDescription: The num ber of RF m odules t hat  m ay be inst alled in t he Rem ot e Unit .Values: Num ber bet ween 1 and 4Default: 1Syntax: Unsigned32Access Level: Read Only
Prism  MI B Obj ect s  Page 276 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Common Managed ObjectsPrism DART MappingI nde xSNMP MIB: fwuDARTMappingIndex Description: I ndex of DART Mapping Table.Values: Num ber bet ween 0 and 100Syntax: Unsigned32Access Level: Not AccessibleUnit  I dSNMP MIB: fwuUnitIDDescription: I dent ifier for t he unitSyntax: HOSTNBR- TYPEAccess Level: Read OnlyUnit   D ART I dSNMP MIB: fwuUnitDARTIDDescription: I dent ifier of DART on the unitValues: Num erical value t hat  can be from  1 t o 8Syntax: I nteger32Access Level: Read OnlyUnit  SFP I dSNMP MIB: fwuUnitSFPIDDescription: I dent ifier of unit  SFP connect ed toward t he m ate DART ( out going) .Values: Num erical value t hat  can be from  1 t o 8Syntax: I nteger32Access Level: Read OnlyUnit  D ART Pa ssba ndSNMP MIB: fwuUnitDartPassBandDescription: Band-Passband inform at ion of the linked DART on the Host side. Values: Num erical value t hat  indicat es size, and t hat  can be from  0 to 40Syntax: OCTET STRI NGAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 277ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Mate I dSNMP MIB: fwuMateIDDescription: I dent ifier of ( com panion) m at e unitValues: See “ Unit  I dentificat ion”  on page 43Syntax: REMOTENBR- TYPEAccess Level: Read OnlyMat e D ART I dSNMP MIB: fwuMateDARTIdDescription: I dent ifier of ( com panion) DART on m at e unit.Syntax: I nteger32Access Level: Read OnlyMat e SFP I dSNMP MIB: fwuMateSFPIdDescription: I dent ifier of rem ot e side SFP connect ed t oward t he unit DART ( incom ing) Syntax: I nteger32Access Level: Read OnlyMate DART Pa ssbandSNMP MIB: fwuMateDartPassbndDescription: Band-Passband inform at ion of t he linked DART on the Mat e side.Syntax: OCTET STRI NGAccess Level: Read OnlySt a rt Tim e Slot  on  SFPSNMP MIB: fwuSfpStartTimeSlotDescription: St art ing t im e slot  on the fiber t hat  is carrying t he RF t raffic from  unit  to m ate DART Module. Values: 1- 12Syntax: I nteger32Access Level: Read OnlyEnd Tim e Slot  on SFPSNMP MIB: fwuSfpEndTimeSlotDescription: Ending t im eslot  on the fiber t hat  is carrying t he RF t raffic from  unit  to m ate DART Module.Values: 1- 12Syntax: I nteger32Access Level: Read Only
Prism  MI B Obj ect s  Page 278 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Mapping St a t usSNMP MIB: fwuMappingStatus Description: St atus of DART m apping tableSyntax: Row St at u sAccess Level: SetSchedule System Link TestSyst em  Link Te st  ModeSNMP MIB: sysLinkTestMode Description: RLM Test  for System .Values: 0 =  Disable1 =  Enable Syntax: I NTEGER Access Level: Read- Writ eSt a rt Dat e a nd Tim eSNMP MIB: sysLinkStartTime Description: The St art  dat e and tim e of linking t est  execution.Syntax: Dat eAndTim eAccess Level: Read- Writ eRecur rence  Tim e  SNMP MIB: sysLinkRecurrenceTime Description: Recurrence of syst em  link test , in t erm s of days. Values: 1 -  3650 =  don't recurSyntax: Unsigned32Access Level: Read- Writ eDART Band TypeSNMP MIB: sysLinkDARTBandType Description: Band t ype ( t he RF DART type)  of select ed unit sValues: See “ Band Types”  on page 235.Enter 0 to select  all unit s.Syntax: BandTypeAccess Level: Read- Writ e
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 279ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.DART I dSNMP MIB: fwuSchLinkTestDartIdDescription: I n which slot t he DART resides.Values: 1 -  8Syntax: I ntegerAccess Level: Read- Writ eSNMP SettingsV1  Trap Agent Addr ess Override M odeSNMP MIB: fwuV1TrapAgentAddrOverrideModeDescription: V1 trap agent  address override m ode.Values: 0 =  Disable1 =  EnableDefault: 0Syntax: I NTEGERAccess Level: Read- Writ eV1  Trap Agen t  Addr ess Ove rride I P AddressSNMP MIB: fwuV1TrapAgentAddrOverrideIPAddrDescription: V1 trap agent  address overriding addressSyntax: DisplaySt ringAccess Level: Read- Writ eSN M P Tra p Resend I nt e rvalSNMP MIB: fwuSnmpTrapResendIntervalDescription: I nt erval in m inut es that  m ust  pass before t he t rap is resent  Values: 0 t o 1440, where 0 =  DisableSyntax: I nteger32Access Level: Read- Writ eMax im um  for SN MP Tr ap Resend SNMP MIB: fwuSnmpTrapResendMaximumDescription: Maxim um  num ber of t im es t rap will be r esent  wit h   Disable =  0Values: 0 t o 360Syntax: I nteger32Access Level: Read- Writ e
Prism  MI B Obj ect s  Page 280 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Et her net  M odem  W ake UpSNMP MIB: fwuEthernetModemWakeUpDescription: I f an ext ernal m odem  is used, sends a “ wake up”  m essageValues: 0 =  False1 =  TrueSyntax: I nteger32Access Level: Read- Writ eRegister SNMP Trap ManagerRow  I nde xSNMP MIB: fwuTrapMgrRowId Description: I ndex for t his t ableSyntax: I ntegerAccess Level: Read- Writ eTr ap M ange r I P Addr essSNMP MIB: fwuTrapMgrIpAddressDescription: I P Address of the regist ered Trap m anagerValues: Default  =  127.0.0.1Syntax: I pAddressAccess Level: Read- Writ eList e ning PortSNMP MIB: fwuTrapMgrListeningPortDescription: Port at  which t he m anager listens for the t rap. This value m ust  be set  by t he user before the row stat us is m ade act ive. Ot herwise, an error will be indicated.Values: 162, or any other unreserved portDefault: 162Syntax: I ntegerAccess Level: Read- Writ eCom m unit ySNMP MIB: fwuTrapCommunityDescription: Trap Com m unit y for the m anagerValues: PublicPrivat eDefault: PublicSyntax: DisplaySt ringAccess Level: Read- Writ e
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 281ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Tr ap Ve rsionSNMP MIB: fwuTrapVersionDescription: Version of SNMP used for t his t rap dest inat ion.Values: 0 =  V11 =  V2c2 =  I nformDefault: 1Syntax: I ntegerAccess Level: Read- Writ eRow  St a t usSNMP MIB: fwuTrapMgrRowStatusDescription: The st atus of t his concept ual row.Syntax: RowSt atusAccess Level: Read- Cr eat eGeographic LocationsGEO ObjectsGeo Hea rtbeat  Tim erSNMP MIB: fwuGeoHeartbeatTimerDescription: Heart beat can be sent  at  the tim er specified here in m inutesValues: Num ber that  represents m inutes, t hat  can be from  1 to 30Default: 20Syntax: I nteger32Access Level: Read OnlyGEO Table ObjectsI nde xSNMP MIB: fwuGeoIndexDescription: I ndex of Geo t able.Values: Num ber that  can be from  0 to 64Syntax: Display StringAccess Level: Read- Writ eGeo La t it udeSNMP MIB: fwuGeoLatitudeDescription: I dent ifies t he Lat it ude of a Rem ot e Unit .Syntax: Lat AndLongAccess Level: Read- Writ e
Prism  MI B Obj ect s  Page 282 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Geo Longit udeSNMP MIB: fwuGeoLongitudeDescription: I dent ifies t he Longit ude of a Rem ot e Unit .Syntax: Lat AndLongAccess Level: Read- Writ eGeo Rem ot e  N a m eSNMP MIB: fwuGeoRmtNameDescription: Derived from  fwuRmtName. Syntax: Display StringAccess Level: Read OnlyGeo St a t usSNMP MIB: fwuGeoStatusDescription: St andard SNMP row st at us for t his table. Values: 0 =  not  Present 1 =  act ive2 =  inact ive Syntax: I ntegerAccess Level: Read OnlyManaged Objects for TrapsPrism Input Contact Alarm Management TableUnit  I ndexSNMP MIB: fwuUnitIndexDescription: The num ber of unit connect ed.Values: See “ Unit  I dentificat ion”  on page 43Syntax: NodeAddr1Access Level: Read OnlyAla rm  CodeSNMP MIB: fwuSYstemAlarmCodeDescription: An alphanum eric code t hat  uniquely ident ifies an alarm / fault .Values: Each alarm / fault  has a unique alphanum eric code. See “ Troubleshoot ing Alarm s”  on page 185 or use t he “ I ndex of Alarm s”  on page  313 t o find t he page num ber for a specific alarm  description, which includes t he alarm  code.Syntax: Unsigned32Access Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 283ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Con t act  AlarmSNMP MIB: fwuContactAlarmDescription: Hardware Assigned Nam eSyntax: Display StringAccess Level: Read OnlySe ve r it ySNMP MIB: fwuContactAlarmSeverityDescription: Severit y of the alarmValues: 2=  Minor3 =  Maj orDefault: MinorSyntax: Unsigned I nt eger Access Level: Read- Writ eMode  SNMP MIB: fwuContactAlarmModeDescription: Mode of t he AlarmValues: 1= Norm ally Closed2 =  Norm ally OpenDefault: 2Syntax: Unsigned I nt egerAccess Level: Read- Writ eAla rm  N am eSNMP MIB: fwuContactAlarmNameDescription: User Assigned Nam eValues: Alphanum eric Charact ers. Except  as first  character, t he underscore ( _) charact er and spaces are allowed. Must  be 5 to 40 characters in lengt h.Default: Blank (em pty st ring)Syntax: Display StringAccess Level: Read- Writ eCont a ct  Alarm  En ableSNMP MIB: fwuContactAlarmEnableDescription: Enable/ Disable the cont act  alarmValues: 1 =  Enabled 0 =  Disabled Default: EnabledSyntax: Unsigned I nt egerAccess Level: Unsigned I nt eger
Prism  MI B Obj ect s  Page 284 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011System Active Alarm TableAla rm  Se quence nu m ber SNMP MIB: fwuSystemAlarmSequenceNumberDescription: I ndex and unique I D for each t rap in Alarm Table.Values: I ndex of t he Alarm TableSyntax: Unsigned32Access Level: Not AccessibleUnit  N ode  Addr ess SNMP MIB: fwuSystemAlarmTrapNodeAddressSyntax: UnitI d2Access Level: Read- Writ eSyst em  LabelSNMP MIB: fwuSystemlabelDescription: Syst em  Nam e or Host nam eSyntax: DisplaySt ringAccess Level: Read OnlyRem ot e  N a m e  for Ala rmSNMP MIB: fwuSystemAlarmRmtNameDescription: Rem ot e nam e, where t he alarm  originat ed.Syntax: DisplaySt ringAccess Level: Read OnlyRem ot e  Type  for  Ala rmSNMP MIB: fwuSystemAlarmRmtTypeDescription: I dent ifies t he type of the Rem ot e ( PRU or URU)Syntax: UnitTypeAccess Level: Read OnlyModu le Type for Ala rmSNMP MIB: fwuSystemAlarmModuleTypeDescription: Hardware m odule t ype, where t he alarm  has originat ed like . SeRF, DART, SFP, LPA, LNA.Syntax: ModuleTypeAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 285ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Modu le N um ber  for   Alar mSNMP MIB: fwuSystemAlarmModuleNumberDescription: Hardware m odule num ber, where t he alarm  has originat ed. Values: Bet ween 1 and 8Syntax: Unsigned32Access Level: Read OnlyModu le N a m e for Ala rmSNMP MIB: fwuSystemAlarmModuleNameDescription: Nam e of hardware m odule where t rap originated.Syntax: DisplaySt ringAccess Level: Read OnlyAla rm  Se ve rit ySNMP MIB: fwuSystemAlarmSeverityDescription: Severit y of the alarmSyntax: Alarm TypeAccess Level: Read OnlyAla rm  Pa ss Band SNMP MIB: fwuSystemAlarmRFBand Description: Describes the Band that  m ay be affected due the raised alarm  PCS, GSM, AWS. Syntax: DisplaySt ringAccess Level: Read OnlyAla rm  Tim eSNMP MIB: fwuSystemAlarmTimeStampDescription: Tim e at  t rap in raised.Syntax: Syst em Dat eand Tim eAccess Level: Read OnlyAla rm  CodeSNMP MIB: fwuSystemAlarmCodeDescription: An alphanum eric code t hat  uniquely ident ifies an alarm / fault .Values: Each alarm / fault  has a unique alphanum eric code. See “ Troubleshoot ing Alarm s”  on page 185 or use t he “ I ndex of Alarm s”  on page  313 t o find t he page num ber for a specific alarm  description, which includes t he alarm  code.Syntax: Unsigned32Access Level: Read Only
Prism  MI B Obj ect s  Page 286 FlexWave Prism  Elem ent Managem ent  System  7.1 User Manual© 2011 ADC Telecommunications, Inc ADCP-77- 177 • I ssue 1 • July 2011Ala rm  Host  N u m berSNMP MIB: SystemAlarmHstNbrDescription: Num ber ident ifying the host in t he syst emSyntax: Unsigned32Access Level: Read OnlyAna log Node  Addr essSNMP MIB: fwuSystemAlarmAnalogAddress Description: Analog Portion of the node addressSyntax: UnitI D3Access Level: Read Writ eAlarm Management TableAla rm  CodeSNMP MIB: fwuSystemAlarmCodeDescription: An alphanum eric code t hat  uniquely ident ifies an alarm / fault .Values: See  “ Troubleshoot ing Alarm s”  on page 185 or use the “ I ndex of Alarm s”  on page 313 t o find t he page num ber for a specific alarm  description, which includes t he alarm  code.Syntax: Unsigned32Access Level: Read OnlyAla rm  Cont r olSNMP MIB: fwuSystemAlarmManageable Description: I ndicat es t he abilit y t o Enable or Disable  alarmValues: Enable =  1Disable = 0Syntax: UpdatedAccess Level: Read OnlyAla rm  Th re sh oldSNMP MIB: fwuSystemAlarmThresholdDescription: The threshold at  which the alarm  is raised ( Whenever applicable)Values: See  “ Troubleshoot ing Alarm s”  on page 185 or use the “ I ndex of Alarm s”  on page 313 t o find t he page num ber for a specific alarm  description, which includes the alarm  t hreshold, if any.Syntax: DisplaySt ringAccess Level: Read Only
Using an SNMP I nt erfaceFlexWave Prism  Elem ent Managem ent  Syst em  7.1 User Manual Page 287ADCP- 77- 177  • I ssue 1 • July 2011 ©  2011 ADC Telecom m unicat ions, I nc.Ala rm ed Module SNMP MIB: fwuSystemAlarmModTypeDescription: I dent ifies t he m odule type t hat  raised t he alarm .Values: SeRFDARTLPALNAPower Det ectorSFPSyntax: I nteger32Access Level: Read OnlyAlarm Enable TableAla rm  CodeSNMP MIB: fwuSystemModuleAlarmcodeDescription: An alphanum eric code t hat  uniquely ident ifies an alarm / fault .Values: See  “ Troubleshoot ing Alarm s”  on page 185 or use the “ I ndex of Alarm s”  on page 313 t o find t he page num ber for a specific alarm  description, which includes t he alarm  code.Syntax: Unsigned32Access Level: Read OnlyN ode AddressSNMP MIB: fwuSystemTrapNodeAddressSyntax: UnitI d2Access Level: Read OnlyAla rm ed Module N um berSNMP MIB: fwuSystemAlarmModuleNoDescription: I dent ifies t he specific m odule t ype t hat  raised t he alarm .Values: SeRFDARTLPALNAPower Det ectorSFPSyntax: Unsigned32Access Level: Read Only