ADC Telecommunications PSM230WM FWP-W4MT000MOD User Manual

ADC Telecommunications Inc FWP-W4MT000MOD

user manual

Dual-Band Dual-Slot RF ModuleSingle-Slot RF ModuleLegacy Dual-Slot 40W RF ModuleHDM RF ModuleFlexWavePrism Remote Unit RF ModuleInstallation GuideTECP-77-141 · Issue 8 · August 2015TE Connectivity, TE and TE connectivity (logo) FlexWave, InterReach, InterReach Fusion and InterReach Unison are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners.The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity's obligations shall only be as set forth in TE Connectivity's Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.This installation guide provides the information you need to install TE Connectivity FlexWave Prism RF Modules into a Prism Remote Unit (PRU). Installation instructions are provided for the following Prism Remote Unit RF Modules:•Single-Bay RF Modules, which includes the HDM RF Modules•Dual-Bay RF Modules–Dual-Band RF Modules–Legacy 40W RF Modules.
Page 2 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015TABLE OF CONTENTSDocument Overview ...........................................................................................................................................................................................3Revision History.......................................................................................................................................................................................................5Document Cautions and Notes ...............................................................................................................................................................................5Abbreviations Used in this Guide............................................................................................................................................................................5Overview of RF Modules for Prism Remote Units ................................................................................................................................................6RF Module Digital/Analog Radio Transceivers ........................................................................................................................................................7RF Module Types.....................................................................................................................................................................................................9Single- and Dual-Bay RF Modules with Classic or SuperDARTs .......................................................................................................................9HDM RF Modules ..........................................................................................................................................................................................10Legacy Dual-Bay 40W RF Modules ................................................................................................................................................................11RF Module Components ....................................................................................................................................................................................12Linear Power Amplifiers ........................................................................................................................................................................................13Duplexer and Low Noise Amplifier........................................................................................................................................................................14Digital Processing Module.....................................................................................................................................................................................14Cables ....................................................................................................................................................................................................................14RF Group Assignments for PRU RF Module Bays ................................................................................................................................................15Understanding RF Cable Rules...........................................................................................................................................................................18RF Module Cables and Supported Bay Use for Single-Card, Dual-Card, and HDM RF Modules ...........................................................................18RF Module Cables and Supported Bay Installations for Legacy Dual-Bay 40W RF Modules.................................................................................20Install the RF Module(s) ....................................................................................................................................................................................21Safety Precautions.................................................................................................................................................................................................21Guard against Damage from Electro-Static Discharge ..........................................................................................................................................22Unpack and Inspect the RF Module ......................................................................................................................................................................22Remove Release Liners from the RF Module ........................................................................................................................................................23Check the DC Power Switch for the Module Bay ..................................................................................................................................................24Dual-Bay Modules Only—Remove the Module Bay Shelf.....................................................................................................................................25Install the RF Module into the Prism Remote Chassis...........................................................................................................................................26Secure RF Module Latches ....................................................................................................................................................................................34Connect Latches on Single-Bay and HDM RF Modules .................................................................................................................................34Connect Latches on Dual-Bay RF Modules....................................................................................................................................................35Latches on Legacy Dual-Bay 40W RF Modules..............................................................................................................................................36Verify that the RF Module Mounting Hook is Engaged.................................................................................................................................36Connect the RF Module Cables to the PRU Chassis ..............................................................................................................................................36Connecting Cables in a Single-Bay RF Module Installation ...........................................................................................................................37Connecting Cables in a Dual-Bay RF Module Installation..............................................................................................................................40Power on the RF Module(s) and the Prism Remote Unit......................................................................................................................................44Close the Remote Unit Door and Solar Shield.......................................................................................................................................................46Provision the Prism Remote Unit..........................................................................................................................................................................46FlexWave Notch Filter (FWP-SPRINTFILTER) ......................................................................................................................................................47Standards Certification......................................................................................................................................................................................49Accessing User Documentation on the TE Customer Portal................................................................................................................................50Contacting TE Connectivity................................................................................................................................................................................51
FlexWave Prism Remote Unit RF Module Installation Guide Page 3TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityDOCUMENT OVERVIEWTable 1 lists the RF Modules that this installation guide supports. Table 1. FlexWave Prism RF Modules Supported in this Installation Guide Catalog Number DescriptionHigh-Density Module (HDM); Single BayFWP-L4MT000MOD 20W 700 lABC Module, MIMO HDM, Single-BayFWP-L4MTU4MMOD 20W 700 lABC/700uC, Dual, Single-BayFWP-U4MT000MOD 20W 700 uC Module, MIMO HDM, Single-BayFWP-44MT000MOD 20W 800 MIMO, Single Bay, with two External FiltersFWP-441T841MOD 20W 800 SMR/ 1900 PCS, Dual RF Module FWP-C4MT000MOD 20W 850 Cell/1900 PCS, Dual, Single-BayFWP-B4MT000MOD 20W 850 DUAL, MIMO, Single BayFWP-84MT000MOD 20W 1900 PCS Dual MIMO, Single-BayFWP-84MTA4MMOD 20W 1900/2100 Dual, Single BayFWP-W4MT000MOD 20W 2300 WCS FDD, MIMO HDM, Single-BayFWP-A416000MOD 20W AWS Module, Non-Diversity, HDM, Single BayFWP-A4MT000MOD 20W AWS Band 4 MIMO HDM, Single-BayFWP-8416000MOD 20W PCS Module, Non-Diversity, HDM, Single BayFWP-B410000MOD 20W Wideband Cell Module, Non-DiversityFWP-A81T000MOD 40W AWS Band 4 SISO HDM, Single-BayFWP-881T000MOD 40W PCS Band 2 & 25 SISO HDM, Single-BayFWP-B810100MOD 40W Wideband Cell Module, Non-Diversity, Single-BaySingle SuperDART; Single BayFWP-I210000MOD 6.5W 800 APAC Module, Non-Diversity, Classic (Extended 1 MHz)FWP-6216000MOD 10W 900 EGSM, Non-Diversity, Single SuperDARTFWP-K216000MOD 10W 900 P-GSM Module, Non-Diversity, Single SuperDARTFWP-F216000MOD 10W APAC EGSM Module, Single SuperDARTFWP-7416000MOD 20W 1800 GSM, Non-Diversity, Single SuperDARTFWP-9416D00MOD 20W 2100 UMTS Module, DIV Ready, Single SuperDARTFWP-9416000MOD 20W 2100 UMTS, Non-Diversity, Single SuperDARTFWP-L416000MOD 20W 700 Lower ABC Module, Non-Diversity, Single SuperDARTFWP-U416000MOD 20W 700 LTE, UPPER C, SISO, Single SuperDARTFWP-U816100MOD 40W 700 Upper C Module, Non-Diversity, Single SuperDART, Single-BayDual SuperDART; Single BayFWP-741S000MOD 20W 1800 GSM, Non-Diversity, DL SuperDARTFWP-A41S000MOD 20W AWS 2100 12SFWP-841S000MOD 20W PCS 1900 12SFWP-941S000MOD 20W, UMTS 2100, Non-Diversity, DL SuperDART
Page 4 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015The RF Modules listed in Table 1 are compatible only with the Remote Units listed in Table 2.Table 2. Supported FlexWave Prism Remote Unit ChassisCatalog Number DescriptionSingle-Bay Prism RemoteDual-Bay Prism RemoteTri-Bay Prism RemoteQuad-Bay Prism RemoteTwo Single SuperDARTs; Diversity; Single BayFWP-6226000MOD 10W 900 EGSM, Diversity, Single SuperDARTFWP-K226000MOD 10W 900 P-GSM Module, Diversity, Single SuperDARTFWP-7426000MOD 20W 1800 GSM, Diversity, Single SuperDARTFWP-9426000MOD 20W, 2100 UMTS, Diversity, Single SuperDARTFWP-A426000MOD 20W AWS Module, Diversity, Single SuperDARTFWP-8426000MOD 20W PCS Module, Diversity, Single SuperDARTClassic DART; Single BayFWP-4210000MOD 6.5W 800 SMR Module, Non-Diversity, ClassicFWP-8420000MOD 20W 1900 PCS DiversityFWP-8410000MOD 20W 1900 PCS Non-DiversityFWP-A420000MOD 20W 2100 AWS DiversityFWP-A410000MOD 20W 2100 AWS Non-DiversityFWP-B420000MOD 20W Wideband Cell Module, Diversity, ClassicFWP-J410D00MOD 20W 850 Cell (870-890) Module, Diversity Ready, ClassicClassic DART; Two-BayFWP-8810000MOD 40W PCS Module, Non-Diversity, Classic (Dual-Bay)FWP-A810000MOD 40W AWS Module, Non-Diversity, Classic, Dual-BayDual Classic DART; Two-BayFWP-D210000MOD 6.5W 800/900 ESMR Module, Non-Diversity, ClassicFP1-XXXXXXXXXXXRU FP2-XXXXXXXXXXXRUFP3-XXXXXXXXXXXRUFP4-XXXXXXXXXXXRUTable 1.  FlexWave Prism RF Modules Supported in this Installation Guide (Cont.)Catalog Number Description
FlexWave Prism Remote Unit RF Module Installation Guide Page 5TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityRevision HistoryTable 3. Revision HistoryIssue Document Date Technical Updates1April 2012 Original2February 2013 Changed Prism Remote Unit model names from Single-/Dual-/Tri-/Quad-Band to Single-/Dual-/Tri-/Quad-Bay. (TECP-77-201).3May 2013 Added “Understanding RF Cable Rules” on page 18..4October 2013 Added the 20W AWS Band 4 MIMO HDM, 40W AWS Band 4 SISO HDM and 40W PCS Band 25 SISO HDM RF Modules.5January 2014 Added FWP-84MT000MOD and FWP-L4MTU4MMOD RF Modules, and added Table 13 on page 39.6August 2014 Added support for FWP-B4MT000MOD, FWP-44MT000MOD, and FWP-84MTA4MMOD RF Modules; added the external FlexWave Notch Filter (FWP-SPRINTFILTER), see “FlexWave Notch Filter (FWP-SPRINTFILTER)” on page 47. 7December 2014 Added caution about potential temporary loss of RF for HDM RF Modules after closing the chassis door.8March 2015 Adds support for the Dual 20W 2300 WCS FDD, MIMO, Single-Bay RF Module (FWP- W4M T000MOD); adds “Close the Remote Unit Door and Solar Shield” on page 46.Document Cautions and NotesTwo types of messages, identified below, appear in the text:CAUTION! Cautions indicate operations or steps that could cause personal injury, induce a safety problem in a managed device, destroy or corrupt information, or interrupt or stop services.NOTE: Notes contain information about special circumstances.Abbreviations Used in this GuideCDRH Center for Diseases and Radiological Health LVDS Low-Voltage Differential Signalingcm Centimeter MHz MegahertzDART Digital/Analog Radio Transceiver MIMO Multiple-Input Multiple-OutputdB Decibel MOD ModuledBm Decibel-milliwatts PA Power AmplifierDCS Distributed Call Signaling PRIM PrimaryDD Digital Dividend PRU Prism Remote UnitDIV Diversity PWR PowerDPM Digital Processing Module REV ReverseEMC Electromagnetic Compatibility RF Radio FrequencyESD Electro-Static Discharge Rx ReceiveEU European Union SDART Super Digital/Analog Radio TransceiverFCC Federal Communications Commission SeRF Serialized RFFDA Food and Drug Administration SFP Small Form-Factor PluggableFRU Fullband Remote Unit TIM Thermal-Interface MaterialFWD Forward Tx TransmitHDM High Density Module UL Underwriters' Laboratories, Inc.HMFOC Hardened Multi-Fiber Optic Connector UMTS Universal Mobile Telecommunications SystemIC Industry Canada WWattLED Light-Emitting Diode WCS Wireless Communications Services
Page 6 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015OVERVIEW OF RF MODULES FOR PRISM REMOTE UNITSFigure 1 illustrates the Prism Remote Unit (PRU), which controls RF emissions, interfaces with the FlexWave Prism Host Unit.Single-BayPrism Remote UnitDual-BayPrism Remote UnitTri-BayPrism Remote UnitQuad-BayPrism Remote UnitFigure 1. Prism Remote Units (PRUs)Depending on the Prism Remote Unit model, a PRU enclosure can have from one to four RF Module bays and can support up to four RF Modules, as indicated by the model name. That is, the Single-Bay PRU has one RF Module bay and can only support one RF Module, and the Quad-Bay PRU has four RF Module bays and can support up to four RF Modules. The function of the Remote Unit RF Modules on the Forward Path is to:•convert the digitized RF transported from the Host to Analog RF•amplify the Analog RF signal•provide signal filtering.The function of the Remote Unit RF Modules on the Reverse Path is to:•convert the Analog RF from the handset to Digital RF for transport to the Host•amplify the Digital RF signal•provide signal filtering.NOTE: The RF Modules are field replaceable, but cannot be serviced in the field.
FlexWave Prism Remote Unit RF Module Installation Guide Page 7TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityRF Module Digital/Analog Radio TransceiversEach RF Module can support any of the following Digital/Analog Radio Transceiver (DART) combinations:•one Classic DART or one Single SuperDART•two Classic DARTs (i.e., the 6.5W 800/900 ESMR Module, Non-Diversity, Classic)•two Classic DARTs—Diversity•two Single SuperDARTs—Diversity•one Dual SuperDART•one or two sets of Tx and Rx Boards (HDM).Each RF Module will have up to two 6-timeslot DARTs or one 12-timeslot DART per RF Module.The DART type determines the maximum number of links, where there can be up to eight Classic DARTs or Single SuperDARTs that support 39 MHz each, or up to 4 Dual SuperDARTs that support up to 75MHz each. Prism supports the DART Module types listed below.•Classic DARTs are 6-timeslot DARTs that support up to 35 MHz contiguous bandwidth (see Table 4 on page 7).•Single SuperDARTs are 6-timeslot DARTs that support two non-contiguous bands in the entire frequency range of the DART, but cannot exceed 39 MHz total RF bandwidth (see Table 5 on page 8).•Dual SuperDARTs are 12-timeslot DARTs that support up to 60-75 MHz (see Table 6 on page 8)Table 4. Single-Position Classic DARTsDART Module Type Maximum Bandwidth (MHz) Maximum Fiber Slots800 APAC iDEN Classic 19 3800 SMR Classic 7* 3850 Cell Classic 25 4900 SMR Classic 5 1* Classic Prism RF Modules and Spectrum RAU support 18 MHz; Prism HDM 800 only supports 7 MHz, per Sprint direction.NOTE: Industry Canada PCS 20 dB nominal bandwidth is less than 61.5 MHz.NOTE: Industry Canada AWS 20 dB nominal bandwidth is less than 47.2 MHz
Table 5. Single-Position SuperDARTs(1) DART Name Used in… MaximumFrequencySpan (MHz)Maximum Bandwidth(MHz)MaximumFiberSlotsHost Units HEUs1800 GSM SGL SuperDART Yes No 75 39 61900 PCS SGL SuperDART Yes Yes 70 39 62100 AWS SGL SuperDART Yes Yes 45 39 62100 UMTS SGL SuperDART Yes No 60 39 6700 IABC SGL SuperDART Yes Yes 18 18 3700 uC SGL SuperDART Yes Yes 10 10 2900 EGSM SGL SuperDART Yes No 35 35 6(1) When using a Host Unit with both a SeRF II and System Board II or III, the bandwidths and fiber for the following Single SuperDARTs can be greater than 6 fiber slots, for full-band capability, when used in Host Unit Slots 1 and 3:•1800 GSM SGL SuperDART •1900 PCS SGL SuperDART •2100 AWS SGL SuperDART •2100 UMTS SGL SuperDART This requires 12 fiber slots when full-band passband is selected for these Single SuperDARTs in Host Unit DART positions 1 and 3.Table 6. Dual-Position SuperDARTsDART Module Type MaximumBandwidth(MHz)MaximumFiberSlots1800 GSM DL SuperDART 75 121900 PCS DL SuperDART 70 122100 AWS DL SuperDART 45 82100 UMTS DL SuperDART 60 12Page 8 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015
FlexWave Prism Remote Unit RF Module Installation Guide Page 9TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityRF Module TypesThe Remote Unit RF Modules are available in the following formats, and as described in the following sections:•“Single- and Dual-Bay RF Modules with Classic or SuperDARTs” on page 9•“HDM RF Modules” on page 10•“Legacy Dual-Bay 40W RF Modules” on page 11.Single- and Dual-Bay RF Modules with Classic or SuperDARTsFigure 2 shows examples of Single- and Dual-Bay RF Modules, both of which have two DARTs. Single-Bay RF Modules have the following elements:•one or two DARTs•one Duplexer that comprises–one Low Noise Amplifier (LNA)–one Power Detector (PD)•one Linear Power Amplifier (LPA)Dual-Band Dual-Bay RF Modules have the following elements:•two DARTs•two Duplexers, each of which comprises–one Low Noise Amplifier (LNA)–one Power Detector (PD)•one Linear Power Amplifier (LPA)•one Remote DART Interface (RDI) board.Dual-Band Dual-Bay RF ModuleSingle-Bay Dual-Card RF ModuleFigure 2. Single- and Dual-Bay RF Modules•one Remote DART Interface (RDI) board.
Page 10 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015HDM RF ModulesHigh-Density Module (HDM) RF Modules (Figure 3) are designed to provide the ability to deploy either a two 20W Multiple Input Multiple Output (MIMO) paths of the same band, known as a MIMO RF Module; two 20W Single Input Single Output (SISO) with two different bands, known as dual RF Module; or a single 40W Single Input Single Output (SISO) RF Module within a single-bay of a PRU. An HDM RF Module does the following:•interfaces with one Host DART-either Classic or SuperDART, or one CDIU•supports two non-contiguous RF slices up to 39 MHz total bandwidth in a Dual or MIMO configuration•supports full bandwidth in a SISO configuration, up to 75 MHz•supports 20W per band/Path in a Dual/MIMO RF Module•supports up to 40W RF output power in a SISO RF Module.The components of a PRU HDM RF Module are dependent on the module type, as listed in Table 7.Table 7. Components of PRU HDM RF ModulesRF Module Type DPM LPA Duplexer LNA Power Detector Rx Card Tx CardSISO 1111111MIMO/Dual Band Module 1222222Figure 3. HDM RF Modules
FlexWave Prism Remote Unit RF Module Installation Guide Page 11TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityLegacy Dual-Bay 40W RF ModulesThe Legacy Dual-Bay 40W RF Module (Figure 5) is designed for AWS and PCS frequencies and is supported only by Classic DARTs. The Legacy Dual-Bay 40W RF Module comprises:•one Classic DART•one Duplexer that comprises–one Low Noise Amplifier (LNA)–one Power Detector (PD)•two Power Amplifiers (PAs)•one Remote DART Interface (RDI) board.NOTE: This manual describes how to install the PCS 1900 and AWS 2100 Non-Diversity RF Modules. Figure 4. Legacy Dual-Bay 40W RF Module
Page 12 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015RF MODULE COMPONENTSFigure 5 shows typical RF Module components, using the Single-Bay RF Module as an example.MounnglatchMounng hook Duplexer Power Amplifier (PA)DARTsNOTE: The RDI is internal to the RF Module and is therefore not shown.LNA(inside the Duplexer caviy)Figure 5. Single-Bay RF Module ComponentsFigure 6 shows the components of an HDM RF Module.Duplexers Power AmplifierMounng latchMounng hookTx and Rx CardsDPMFigure 6. HDM RF Module Components
FlexWave Prism Remote Unit RF Module Installation Guide Page 13TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityLinear Power AmplifiersThe Linear Power Amplifier (LPA) is a high quality broadband RF amplifier used for achieving Prism product-rated power for the Remote Unit Tx forward path RF. The PAs are pass-band specific, with the maximum composite Tx power levels listed in Table 8 for Single-Card, Dual-Card, and HDM RF Modules and Table 9 on page 13 for Legacy Dual-Bay 40W RF Modules.The LPA is housed within the RF Module, and is not field serviceable.Table 8. LPA Maximum Composite Tx Power Levels for Single-Card, Dual-Card, and HDM RF ModulesBandwidth (MHz) supported across entire spectrumPassband MaximumdBm WattsHDMSingle Super DART ClassicDARTDualSuperDARTDual/MIMO SISOAWS 2100 43 20 39 45 39 NA 4546 40 NA 45 39 NA 45Cellular 850 43 20 25 25 NA 25 NA46 40 25 25 NA 25 NAEGSM 900 40 10 35 35 35 NA NADCS 1800  42 15.8 39 75 39 NA 75LTE 700 Lower ABC 43 20 18 18 18 NA NALTE 700 Upper C 43 20 10 10 10 NA NA46 40 10 10 10 NA NAPCS 1900 43 20 39 70 39 NA 7046 40 39 70 39 NA 70PGSM 900 40 10 25 25 25 NA NASMR 800 43 20 7 7 NA 7NASMR 900 38 6.5 NA NA NA 5NAUMTS 2100 42 15.8 39 60 39 NA 602300 WCS 43 20 10 10 10 NA NATable 9. LPA Maximum Composite Tx Power Levels for Legacy Dual-Bay 40W RF ModulesPassband MaximumdBm WattsBandwidth (MHz)supported acrossentire spectrum Classic DARTPCS 1900 +46 40 35AWS 2100 +46 40 35NOTE: Industry Canada 20 dB Pass Band Model Number FWP-C4MT000MOD Cellular 850 MHz = 26.3 MHz and the PCS 1900 = 66.8 MHz.
Page 14 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Duplexer and Low Noise AmplifierThe RF Module provides the Remote Unit with an internal Duplexer that is optimized to provide the desired RF band-pass filtering and in-band equipment isolation between FWD and REV paths. The Duplexer provides the filtering necessary to the transmit and receive paths to and from the connected antenna. The Duplexer for the Single- and Dual-Bay RF Modules and the Legacy Dual-Bay 40W RF Modules contains up to two REV path Low Noise Amplifiers (LNA for PRI and/or SEC reverse paths). The Duplexer for an HDM RF Module does not have a Low Noise Amplifier.Duplexers are not field serviceable.Digital Processing ModuleThe Digital Processing Module (DPM) is found only in the HDM RF Modules. The DPM provides the primary processing and logic functions for the HDM RF Module. It also provides the primary power interface for the HDM RF Module, and conversion of the native 28 Vdc voltage to lower voltages as necessary for functionality.The DPM has a Transmit (Tx) Board and a Receive (Rx) Board:•Tx Board—provides band specific filtering for the intended Transmit path.•Rx Board—provides band specific filtering for the intended Receive path. CablesAlways provided at each RF Module shelf are five cables:•two High-Speed Data Cables, which in this document are referred to as LVDS (Low-Voltage Differential Signaling) cables•two RF Cables (TX0/RX0) and (TX1/RX1)•one Power (PWR) Cable.The RF Module cables that are pre-installed in the PRU connect to the corresponding connectors on the RF Module. The RF Module cables correlate to the antenna connectors on the bottom of the Remote Unit chassis. •
FlexWave Prism Remote Unit RF Module Installation Guide Page 15TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityRF GROUP ASSIGNMENTS FOR PRU RF MODULE BAYSA PRU comprises from one to four RF Module bays. Figure 7 illustrates the numbering of RF Module bays and DARTs.Quad-Bay Remote Unit with Single-Card RF ModulesSeRF ModuleDART 7DART 8Bay DDART 5DART 6Bay CDART 3DART 4Bay BDART 1DART 2Bay AFigure 7. RF Modules Bays in a PRU
Page 16 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Table 10 lists how the FlexWave Prism EMS references the RF group assignments and corresponding components of each RF Module.Table 10. Remote Unit RF Group Assignments (from Top/Down)Physical RF BayDART NumberLNA Number LPA Numberfor Single LPALPA Number for Dual LPAsPower Detector Number for Single PDPower Detector Number for Dual PDsPrimary DiversityD8 8 78787 7 7 7C6 6 56565 5 5 5B4 4 34343 3 3 3A2 2 12121 1 1 1NOTE: For software releases prior to 7.3, the LPAs were labeled as 1, 2, 3, and 4.NOTE: For Classic dual position 40W RF Modules only: in a dual LPA system, the Configure Remote Forward Gain page shows two values for the LPA status, one for each LPA. Changing the LPA Mode or resetting the LPA applies to both LPAs at the same time.CAUTION! Should your system experience an LPA problem, refer to Table 10 to ensure that you apply new settings or troubleshoot the correct RF Module.The Legacy Dual-Bay 40W RF Module occupies two bays in a PRU. Figure 8 shows the main components in a PRU enclosure, with a Legacy 40W RF Module occupying Bays A and B. The controlling DART will always be in the upper bay (B or D), and the second LPA is always in the lower bay (A or C).
Legacy Dual-Bay 40W RF Modulein Bay B (upper slot) and Bay A (lower slot) with the controlling DART in Bay BAC or DC power switchFour DC power switchesSeRF Module and Power suppliesBay C (empty for future use)Bay D (empty for future use)FansConnecvity panel with Status LEDFlexWave Prism Remote Unit RF Module Installation Guide Page 17TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityFigure 8. Legacy Dual-Bay 40W RF Module in a Quad-Bay PRUNOTE: If a Legacy Dual-Bay 40W RF Module AWS 2100 and a Legacy Dual-Bay 40W RF Module PCS 1900 are both installed in a Quad-Bay PRU, it is recommended that the PCS 1900 be installed in upper-most bay, and the AWS 2100 be installed in the lower-most bay.NOTE: To accommodate two-bay modules, you need to remove a module bay shelf as described in “Dual-Bay Modules Only—Remove the Module Bay Shelf” on page 25.
Page 18 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015UNDERSTANDING RF CABLE RULES•When installing a Diversity, MIMO or Dual-Band RF Module, both RF cables labeled MOD N TX0/RX0 and MOD N TX1/RX1 shall be connected to the N-Style connections of the RF Module. Note that older labeling schemes used “PRI” and “DIV”. To match old labeling schemes to current labeling:Old Label New LabelPRI TX0/RX0DIV TX1/RX1•When installing a Non-Diversity or SISO RF Module, or an SMR 800/900 Dual-Band Dual-Bay RF Module:–The MOD N TX0/RX0 cable shall be connected to the single available N-Style RF Connection of the RF Module. –The MOD N TX1/RX1 cable shall be constrained to the existing cables using a tie wrap or similarly accepted fastener so it cannot be pinched or prevent the Remote Unit door from closing. Do not cut or attempt to otherwise remove this RF Cable.•RF cables are hand-formable; however, cables must adhere to a minimum bend radius of 1-inch from the outlet of the integrated cable guide to the respective N-Style RF connection on the RF Module. RF Module Cables and Supported Bay Use for Single-Card, Dual-Card, and HDM RF ModulesThe RF cable and connector labels correspond to the RF Module bays in the Remote Unit chassis, where MOD A is the bottom bay and MOD D is the top bay. •The cables and connectors have corresponding labels as shown in Table 11 for Single-Card, Dual-Card, and HDM RF Modules. For Dual-Bay installations, the RF cables and connectors are labeled as MOD N TX0/RX0 and MOD N TX1/RX1, where N refers to the top bay of the double-bay installation. For example:–For a Dual-Bay installation in a Quad-Bay chassis in which the RF Module is installed in the Bay D and Bay C combination, the RF cables and connectors are labeled as MOD D TX0/RX0 and MOD D TX1/RX1.–For a Dual-Bay installation in a Tri-Bay chassis in which the RF Module is installed in the Bay B and Bay A combination, the RF cables and connectors are labeled as MOD B TX0/RX0 and MOD B TX1/RX1.•Table 11 also shows which RF Module type can be installed in which PRU bay or bay combination. •The Single-Bay chassis is not included in Table 11.
Table 11. Supported Bay Use and RF Antenna Labels for Single-Card, Dual-Card, and HDM RF Modules  (From Top of Remote Unit Chassis Down)Supported Bay Configurations for Single-Bay RF Modules Supported Bay Combinationsfor Dual-Bay RF ModulesRF Module Cable, RF Module Connector, and Remote Antenna Connector LabelFunction Supported Bays in Dual-Bay ChassisSupported Bays in Tri-Bay ChassisSupported Bays in Quad-Bay ChassisBay DMOD D N/A N/AMOD DMod D TX0/RX0 Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module DMod D TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module D Bay CMOD C  N/A MOD C Mod C TX0/RX0  Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module CMod C TX1/RX1 Diversity receive/Path 2 for Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module C Bay BMOD BMOD B MOD B MOD BMod B TX0/RX0  Transmit RF power and primary/Path 1receive to/from the antenna for RF Module BMod B TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module B Bay AMOD AMod A TX0/RX0  Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module AMod A TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module A FlexWave Prism Remote Unit RF Module Installation Guide Page 19TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE Connectivity
Page 20 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015RF Module Cables and Supported Bay Installations for Legacy Dual-Bay 40W RF ModulesThe cables and connectors have corresponding labels as shown in Table 12 for Legacy Dual-Bay 40W RF Modules. Table 12 also shows which RF Module type can be installed in which PRU bay(s) when a 40W Dual-Bay RF Module is part of the RF Module mix in a PRU chassis. The Single-Bay chassis is not included in Table 12.For Dual-Bay installations, the RF cables and connectors are labeled as MOD N TX0/RX0 and MOD N TX1/RX1, where N refers to the top bay of the double-bay installation. For example:•For a Dual-Bay installation in a Quad-Bay chassis in which the RF Module is installed in the Bay D and Bay C combination, the RF cables and connectors are labeled as MOD D TX0/RX0 and MOD D TX1/RX1.•For a Dual-Bay installation in a Tri-Bay chassis in which the RF Module is installed in the Bay C and Bay B combination, the RF cables and connectors are labeled as MOD C TX0/RX0 and MOD C TX1/RX1.Table 12. Supported Bay Assignments and RF Antenna Labels for Legacy Dual-Bay 40W RF Modules (From Top of Remote Unit Chassis Down)Supported Bay Combinations for Legacy 40W Dual-Bay RF Modules RF Module Cable, RF Module Connector, and Remote Antenna Connector LabelFunction Dual-Bay Tri-Bay Tri-Bay Quad-BayBay DN/A N/A N/AMOD DMOD DMOD CMod D TX0/RX0 Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module DMod D TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module D Bay CN/A MOD C MOD C MOD CMod C TX0/RX0  Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module CMod C TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module CBay BMOD B MOD B MOD B MOD BMOD BMod B TX0/RX0  Transmit RF power and primary/Path 1receive to/from the antenna for RF Module BMod B TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module B Bay AMOD A  MOD AMod A TX0/RX0  Transmit RF power and primary/Path 1 receive to/from the antenna for RF Module AMod A TX1/RX1 Transmit RF power and secondary/Path 2 receive to/from the antenna for RF Module A Note: For Dual Module installations the center module shelf needs to be removed; see “Dual-Bay Modules Only—Remove the Module Bay Shelf” on page 25.Note: Install the Legacy Dual-Bay 40W RF Module in the lower-most bay in the chassis. If, however, if two Legacy Dual-Bay 40W RF Modules are present, install the 2100 Module in the lower-most Bay and the 1900 Module in the upper-most Bay.
FlexWave Prism Remote Unit RF Module Installation Guide Page 21TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityINSTALL THE RF MODULE(S)The following sections guide you through the installation of an RF Module into a Remote Unit chassis. The process to install the four different types of RF Modules is basically the same; however, differences are noted and should be followed.NOTE: In the following steps, the RF cables and connectors are referred to as MOD N TX0/RX0 and as MOD N TX1/RX1 where N equals A, B, C, or D.NOTE: When installing RF Modules, populate the RF Modules from highest frequency band to lowest within the Remote Unit chassis. Likewise for power output, populate from the bottom bay to the top; higher output to lower output. That is, for a deployment with 2100 40W, 1900 40W, 850 20W and 700 20W MIMO, install the RF Modules as follows:• 2100 40W RF Module in Bay A• 1900 40W RF Module in Bay B• 850 20W RF Module in Bay C• 700 20W MIMO RF Module in Bay D.Safety PrecautionsCAUTION! This is restricted access equipment and only qualified service personnel should service and operate this equipment using appropriate tools.CAUTION! Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm. CAUTION! Always allow sufficient fiber length to permit routing of patch cords and pigtails without severe bends. Fiber optic patch cords or pigtails may be permanently damaged if bent or curved to a radius of less than 2 inches (5.1 cm). CAUTION! Exterior surfaces of the Prism Remote Unit may be hot. Use caution during servicing.CAUTION! Service personnel must confirm that the perimeter gasket and door-to-door gaskets are in place when closing the Remote Unit doors after servicing.CAUTION! This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transceiver of any digital unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transceiver or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the adapter or connector.CAUTION! This system is an RF Transmitter and continuously emits RF energy. Maintain 3 foot (91.4 cm) minimum clearance from the antenna while the system is operating. Wherever possible, shut down the RAN before servicing the antenna.
Page 22 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Guard against Damage from Electro-Static DischargeCAUTION! Electro-Static Discharge (ESD) can damage electronic components. To prevent ESD damage, always wear an ESD wrist strap when working with a Prism Remote Unit or when handling any of its components—including the RF Modules. Connect the ground wire on the ESD wrist strap to an earth ground source before touching the Prism Remote Unit or any of its components. Wear the wrist strap the entire time that you work with the Prism Remote Unit and its components. CAUTION! Place Prism RF Modules in anti-static packing material when transporting or storing them.Unpack and Inspect the RF Module1Inspect the exterior of the shipping container(s) for evidence of rough handling that may have damaged the components in the container.2Unpack each container while carefully checking the contents for damage and verify with the packing slip.3If damage is found or parts are missing, file a claim with the commercial carrier and notify TE Customer Service (see “Contacting TE Connectivity” on page 51). Save the damaged cartons for inspection by the carrier.4Save all shipping containers for use if the equipment requires shipment at a future date. CAUTION! Handle the RF Module with care during installation. Be especially careful to not damage the thermal-interface material (TIM), which is attached to the LPA, DARTs, and/or Motherboard with TX/RX boards. If the TIM is damaged, the LPA can overheat. Before installing the RF Module, check to see if the heatsink material is gouged or cracked. If the TIM is damaged, do not install the RF Module and contact TE Connectivity for assistance (see “Contacting TE Connectivity” on page 51 for contact information).CAUTION! If the thermal-interface material is damaged, the installation and use of the RF Module may void the warranty of the RF Module.
FlexWave Prism Remote Unit RF Module Installation Guide Page 23TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityRemove Release Liners from the RF ModuleNOTE: Release Liners are present on front and back of new modules.1Open the Remote Unit enclosure.2Remove release liners, if present, from the thermal pads on the RF Module prior to installing the module into the Remote Unit chassis.CAUTION! The thermal pads are very sensitive to mishandling—do not nick, scratch, or ding them.For Single- and Dual-Bay RF Modules, the thermal pads are located as listed below and as shown in Figure 9, which shows a Legacy Dual-Bay 40W RF Module.•one large pad on the back surface of each Linear Power Amplifier (LPA)•up to two on the front surface (DARTs)•one on the left side for the (RDI)•one on the vector modulator boardOne largethermal pad on each PA(boom of the LPA)One thermal padfor the RDIOne thermal padfor each DARTOne thermal padfor each DARTOne thermal padfor RF PowerCombinerOne thermal padfor VectorModulator•one on the RF power combiner.Figure 9. Thermal Pads on a Legacy Dual-Bay 40W RF Module
Page 24 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015For HDM RF Modules, the thermal pads are located as listed below and as shown in Figure 10.•one pad for each Rx and Tx board•one large pad over the DPM•one for each Power Amplifier (PA), which is on the bottom of the HDM RF Module. DPM Thermal PadTx A Thermal PadTx B Thermal PadRx A Thermal PadRx B Thermal Pad2.9796 in2.9796 inNOTE: Tx and Rx cards are paired: Tx A ony pairs with Rx A and Tx B only pairs with Rx B.Figure 10. Thermal Pads on an HDM RF ModuleCheck the DC Power Switch for the Module BayDC Power switch for Bay ADC Power switch for Bay BDC Power switch for Bay CDC Power switch for Bay DEnsure that the DC power switch that corresponds to the bay(s) in which the RF Module is to be installed is in the Off position (see graphic to the right).
FlexWave Prism Remote Unit RF Module Installation Guide Page 25TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityDual-Bay Modules Only—Remove the Module Bay Shelf1Use 9/64” Allen Wrench toremove the three module-shelf screwsRemove Module D Shelf forDual-Band Dual-Slot RF ModulesRemove Module B Shelf forDual-Slot 40W RF ModulesFOR DUAL-BAY RF MODULES ONLY.If you are installing a Dual-Bay RF Module, you must remove a module bay shelf from the PRU chassis to accommodate the module’s size. (For further information, see Table 11 on page 19.)Remove the shelf as appropriate for the RF Module:•When installing in the A and B Bays, remove the Module B Bay Shelf.•When installing in the C and D Bays, remove Module D Bay Shelf.To remove a Module Bay Shelf:aUse a 9/64” Allen™ wrench to remove the three screws that attach the module shelf to the PRU chassis, as shown in the following graphic.bDiscard or store the module shelf and fasteners.
Page 26 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Install the RF Module into the Prism Remote Chassis1Hold the RF Module so that the DART card(s) face away from the PRU and the Mounting Hook is toward the Receiving flange on the PRU chassis.NOTE: Always install RF Modules from the bottom up. Do not skip a bay, as this provides more efficient heat dissipation.2Holding the RF Module at a 45° angle in respect to the rear heatsink, rest the bottom surface of the module on the RF Module shelf, as shown in one of the following graphics, and as applicable to the RF Module.•Single-Bay RF Module: Figure 11 on page 26•HDM RF Module: Figure 12 on page 27•Dual-Bay RF Module: Figure 13 on Page 28•Legacy Dual-Bay 40W RF Module: Figure 14 on Page 29.Bay CBay DSeRFModuleBay ABay BSingle-SlotRF ModuleHeat Sink Figure 11. Installing a Single-Bay RF Module
Bay CBay DSeRF ModuleBay ABay BHDM RF ModuleFlexWave Prism Remote Unit RF Module Installation Guide Page 27TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityFigure 12. Installing an HDM RF Module
Installing a Dual-BandDual-Slot RF ModulePage 28 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Figure 13. Installing a Dual-Bay RF Module
FlexWave Prism Remote Unit RF Module Installation Guide Page 29TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityFigure 14. Installing a Legacy Dual-Bay 40W RF Module
Page 30 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 20153Align the Mounting Hook on the module with the receiving flange on the PRU heat sink, and then slide the RF Module in toward the flange until it can go no further.RF ModuleMounnghookChassisReceivingflangeMounng Bracket atback of the PRU(View is looking down into thePRU chassis from the top.)4Push the left edge of the RF Module back and into the PRU chassis until it can go no further, as shown in the following graphics:•For Single-Bay RF Modules, see Figure 15 on page 31.•For HDM RF Modules, see Figure 16 on page 32.•For Dual-Bay RF Modules, see Figure 17 on page 33, which uses the Legacy Dual-Bay 40W RF Module as an example.CAUTION! Make sure the RF Module is seated correctly in the Module shelf. Incorrect alignment of the RF Module can cause the RF Module to fail due to overheating. • The front edge of the RF Module should be parallel with the shelf above it.• The Mounting Hook on the RF Module should be fully engaged with the Receiving flange on the Remote Unit chassis.• An incorrectly seated RF Module makes closing the Prism door difficult. If you later cannot shut the Remote Unit door, verify that the RF Module is installed correctly.
Push the RF Moduleback into the chassisunl it can go no further.Single-SlotRF ModuleFlexWave Prism Remote Unit RF Module Installation Guide Page 31TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityFigure 15. Seating a Single-Bay RF Module
Push the HDM RF Moduleback into the chassisunl it can go no further.HDMRF ModulePage 32 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Figure 16. Seating an HDM RF Module
Push the RF Module backinto the chassis unl it cango no further.FlexWave Prism Remote Unit RF Module Installation Guide Page 33TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityFigure 17. Seating a Dual-Bay RF Module
Page 34 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Secure RF Module Latches1To secure the module latches on the left side of the RF Module, do one of the following, as appropriate for the RF Module being installed:•“Connect Latches on Single-Bay and HDM RF Modules” on page 34•“Connect Latches on Dual-Bay RF Modules” on page 35.Connect Latches on Single-Bay and HDM RF ModulesFor Single-Bay and HDM RF Modules, secure two latches, as shown in Figure 18.Two latches on Single-SlotRF ModulesTwo latches onHDM RF ModulesFigure 18. Latches on Single-Bay and HDM RF Modules
FlexWave Prism Remote Unit RF Module Installation Guide Page 35TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityConnect Latches on Dual-Bay RF ModulesFor Dual-Bay RF Modules, secure four latches, as shown in Figure 19.Four latches in aDual-Band Dual-SlotRF ModuleFigure 19. Dual-Bay RF Module Latches
Page 36 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Latches on Legacy Dual-Bay 40W RF ModulesFor Legacy Dual-Bay 40W RF Modules, secure four latches, as shown in Figure 20.Four latches in a Legacy Dual-Slot 40WRF ModuleFigure 20. Legacy Dual-Bay 40W RF Module LatchesVerify that the RF Module Mounting Hook is EngagedVerify that the RF Module Mounting Hook is engaged correctly by pulling the module away from the heat sink. The RF Module should not move. If the RF Module moves during this check, repeat all the steps starting at “Install the RF Module into the Prism Remote Chassis” on page 26 through this step. Connect the RF Module Cables to the PRU ChassisThe steps to connect the RF Module cables have been separated into two different procedures; follow the steps that correspond to the RF Module being installed.•“Connecting Cables in a Single-Bay RF Module Installation” on page 37•“Connecting Cables in a Dual-Bay RF Module Installation” on page 40.
FlexWave Prism Remote Unit RF Module Installation Guide Page 37TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityConnecting Cables in a Single-Bay RF Module Installation1Position the cables so that they are under the right edge of the RF Module, pointing up.2Follow the rules listed in “Understanding RF Cable Rules” on page 18.3Connect the RF Module cables, in the order shown below. As you work, refer to the graphic that corresponds to the RF Module being installed into a single bay of the PRU: for a Single-Bay RF Module, refer to Figure 21 on page 38, and for an HDM RF Module, refer to Figure 22 on page 39 and Table 13 on page 39.aConnect the MOD N TX0/RX0 cable to the RF Module (the RF cables and connectors are referred to as MOD N TX0/RX0 where N equals A, B, C, or D).iInsert the N-Style Plug of the MOD N TX0/RX0 cable into the TX0/RX0 N-Style Jack of the RF Module.ii Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.iii Torque coupling nut to 8 ±1 in-lbs to ensure full connection.NOTE: Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and higher than normal VSWR reported by the system.bConnect the MOD N TX1/RX1 cable to the RF Module (the RF cables and connectors are referred to as MOD N TX1/RX1 where N equals B, C, or D).iIf a TX1/RX1 RF Module connection is available, insert the N-Style Plug of the MOD N TX1/RX1 cable into the TX1/RX1 N-Style Jack of the RF Module. If RF Module connection is not available, constrain the MOD N TX1/RX1 cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.ii Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.iii Torque coupling nut to 8 ±1 in-lbs to ensure full connection.NOTE: Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and higher than normal VSWR reported by the system.cConnect the LVDS Cables to the RF Module—the LVDS cables labeled PRIM and DIV should always either be connected to a RF Module or strain relieved to adjacent cables, as this protects the cable against damage through misplacement. Maintain adequate strain-relief distances from the connection points to the RF Module.iConnect the MOD N DIV LVDS Cable to the DIV receptacle of the RF Module by inserting and sliding in until fully seated. Full insertion can be recognized by an audible click as the LVDS Cable Connector locks into the RF Module Receptacle.ii Connect the MOD N PRIM LVDS Cable to the PRIM connector, following the same steps as above. Full insertion can be recognized by an audible click as the LVDS Cable Connector locks into the RF Module Receptacle.iii Ensure the two LVDS cables are fully seated and latched into their respective receptacles on the RF Module by lightly pulling outward on the connectors. If fully seated and locked into position, the cable connectors will not slide back out.
Page 38 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015dConnect the Power cable to the PWR receptacle of the RF Module.iEnsure that the  DC power switch that corresponds to the bay(s) in which the RF Module is to be installed is in the Off position (see “Check the DC Power Switch for the Module Bay” on page 24).iInsert the Power cable into the PWR connector, and slide it in until fully seated. Full insertion can be recognized by an audible click as the Power cable Connector locks into the RF Module Receptacle. ii Verify  that  the  Power  cable  is  fully  seated  by  lightly  pulling  back on it while making sure to not depress the release triggers on the ends of the connector. When fully inserted, the cable should not be able to be removed from the receptacle.4Repeat all the steps in “Install the RF Module(s)” on page 21 to install other RF Modules.Bay ABay DBay CBay BSeRFModuleTX0/RX0TX1/RX1DIVPRIMPWRNote roung ofhigh-speed cablesNote bendradii ≥ 1-inchEdge of Connector Interface PanelCable connecons for a Single-Slot RF ModuleFigure 21. Cable Connections for Single-Bay RF Modules
Cable Connecons for an HDM RF ModuleTX0/RX0TX1/RX1POWERDATA 1 (DIV)DATA 0 (PRIM)Cable Connecon Notes• Always connect the Power cable.• Always connect the two LVDS cables: PRIM and DIV.• SISO requires one RF cable (TX0/RX0).• MIMO and Dual-Band require two RF cables   (TX1/RX1 and TX0/RX0).FlexWave Prism Remote Unit RF Module Installation Guide Page 39TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityCAUTION! Ensure that all cable bends are below the top edge of the Connector Interface Panel as indicated by the dashed line in the preceding figure. Failure to correctly position the cables could inhibit closing the Remote Unit door, which can result in damage to the cables.Figure 22. Cable Connections for HDM RF ModulesTable 13 lists how to correctly connect HDM RF Modules to the Antenna ports on the bottom of the Remote Unit.Table 13. HDM Antenna Port MappingRF Module Catalog # Description TX0/RX0 TX1/RX120W 700 lABC Module, MIMO HDM, Single-Bay Path 1 Path 220W 700 uC Module, MIMO HDM, Single-Bay Path 1 Path 220W 700 lABC/700uC, Dual, Single-Bay 700 lABC 700 uC20W 800 MIMO, Single Bay, with two External Filters Path 1 Path 220W 800 SMR/ 1900 PCS, Dual RF Module  1900 80020W 850 DUAL, MIMO, Single Bay Path 1 Path 220W 850 Cell/1900 PCS, Dual, Single-Bay 1900 85020W 1900 PCS Dual MIMO, Single-Bay Path 1 Path 220W 1900/2100 Dual, Single Bay 2100 190020W HDM AWS Band 4 MIMO, Single-Bay Path 1 Path 2(1)  A 20W 800 SMR/ 1900 PCS, Dual RF Module RF Module (FWP-441T841MOD) requires a FlexWave Notch Filter (FWP-SPRINTFILTER) between the Remote Unit and the antenna to provide protection from spurious emissions in the Public Safety band below 861.35 MHz and the Cellular band above 869.5 MHz. Information on how to install the Notch Filter is provided in “FlexWave Notch Filter (FWP-SPRINTFILTER)” on page 47.FWP-L4MT000MODFWP-U4MT000MODFWP-L4MTU4MMODFWP-44MT000MODFWP-441T841MOD (1) FWP-B4MT000MODFWP-C4MT000MODFWP-84MT000MODFWP-84MTA4MMODFWP-A4MT000MOD
Page 40 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Connecting Cables in a Dual-Bay RF Module Installation1Position the cables so that they are under the right edge of the RF Module, pointing up.2Follow the rules listed in “Understanding RF Cable Rules” on page 18.3Working from the bottom connector up, connect the RF Module cables, as described below. As you work, refer to the graphic that corresponds to the RF Module being installed in the Dual-Bay: for a Dual-Bay RF Module, refer to Figure 23 on Page 42, and for a Legacy Dual-Bay 40W RF Module, refer to Figure 24 on Page 43.aConnect the MOD N TX1/RX1 cable to the N-Style RF connector on the Dual-Bay RF Module (the RF cables and connectors are referred to as MOD N TX1/RX1 where N equals B, C, or D).iConstrain the MOD N TX1/RX1 cable of the lower RF Module bay to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.ii Connect the MOD N TX1/RX1 cable to the TX1/RX1 N-Style Jack of the upper RF Module Bay.iii Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.iv Torque coupling nut to 8 ±1 in-lbs to ensure full connection.NOTE: Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and higher than normal VSWR reported by the system.bConnect the MOD N TX0/RX0 cable to the RF Module (the RF cables and connectors are referred to as MOD N TX0/RX0 where N equals A, B, C, or D).iInsert the N-Style Plug of the MOD N TX0/RX0 cable into the TX0/RX0 N-Style Jack of the lower RF Module  bay.  If  RF  Module  connection  is  not  available,  constrain the MOD N TX0/RX0 cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.ii Turn the coupling nut of the plug clockwise to thread onto the jack and finger-tighten.iii Torque coupling nut to 8 ±1 in-lbs to ensure full connection.NOTE: Insufficient torque applied to RF Module connections can result in elevated insertion/return loss and higher than normal VSWR reported by the system.cConnect the LVDS Cables to the RF Module.iIf available, connect  the MOD N DIV LVDS Cable to the DIV receptacle of the lower RF Module by inserting and sliding in until fully seated. If DIV receptacle is not available, constrain the MOD N DIV LVDS Cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing. Full insertion  can  be  recognized  by  an  audible  click  as  the  LVDS  Cable Connector locks into the RF Module Receptacle.ii Connect the MOD N DIV LVDS Cable to the DIV receptacle of the upper RF Module by inserting and sliding in until fully seated. If DIV receptacle is not available, constrain the MOD N DIV LVDS Cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing. Full insertion can be recognized by an audible click as the LVDS Cable Connector locks into the RF Module Receptacle.
FlexWave Prism Remote Unit RF Module Installation Guide Page 41TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE Connectivityiii If available, connect the MOD N PRIM LVDS Cable to the PRIM receptacle of the upper RF Module by inserting and sliding in until fully seated. If DIV receptacle is not available, constrain the N PRIM LVDS Cable to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.iv Ensure the two LVDS cables are fully seated and latched into their respective receptacles on the RF Module by lightly pulling outward on the connectors. If fully seated and locked into position, the cable connectors will not slide back out.dConnect the Power cable to the PWR receptacle of the RF Module.iEnsure that the DC power switch that corresponds to the bay(s) in which the RF Module is to be installed is in the Off position (see “Check the DC Power Switch for the Module Bay” on page 24).ii Insert the Power cable into the PWR receptacle of the lower RF Module bay, and slide it in until fully seated. Full insertion can be recognized by an audible click as the Power cable Connector locks into the RF Module Receptacle. iInsert the Power cable into the PWR receptacle of the upper RF Module bay, and slide it in until fully seated. Full insertion can be recognized by an audible click as the Power cable Connector locks into the RF Module Receptacle. If the PWR receptacle is not available,  constrain  the  Power  cable  to accompanying cables using a tie wrap so it cannot be pinched or prevent the Remote Unit door from closing.ii Verify  that  the  Power  cable  is  fully  seated by  lightly  pulling back on it while making sure to not depress the release triggers on the ends of the connector. When fully inserted, the cable should not be able to be removed from the receptacle.4Repeat all the steps in “Install the RF Module(s)” on page 21 to install other RF Modules.
Cable Connecons for a Dual-Slot RF ModuleTie wrapFactory-installedRX1 cableTwo N-TypeRF connectorsN-TypeRF connectorPage 42 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Figure 23. Cable Connections for Dual-Band Dual-Bay RF Modules
Tie wrap around factory-installedRX1 cableKeep cable bendsbehind the edge of the Connector Interface PanelFlexWave Prism Remote Unit RF Module Installation Guide Page 43TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityFigure 24. Cable Connections for Legacy Dual-Bay 40W RF ModulesCAUTION! Ensure that all cable bends are below the top edge of the Connector Interface Panel as indicated by the dashed line in the preceding figure. Failure to correctly position the cables could inhibit closing the Remote Unit door, which can result in damage to the cables.
Page 44 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Power on the RF Module(s) and the Prism Remote Unit1If necessary, power up the Remote Unit by turning its AC or DC power switch to On.2Ensure that the external Status LED on the bottom of the Remote Unit goes off. Boom of an AC-Powered PRU Boom of a DC-Powered PRUStatus  LEDNETWORKPOWER48VDC/XXAMOD DTX1/RX1NETWORKMOD DTX1/RX1POWER100-240 VAC50-60 HzXX AMPSWARNING:HIGH LEAKAGE CURRENT. EARTHCONNECTION ESSENTIAL BEFORECONNECTING SUPPLYMOD DTX0/RX0MOD DTX0/RX0NOTE: During bootup, this LED will be red. After approximately one minute, the LED should extinguish.NOTE: The preceding graphic illustrates the Status LED on a Quad-Bay PRU. The Status LED for the Single-Bay, Dual-Bay, and Tri-Bay PRUs is in the same location and functions the same as the Status LED for the Quad-Bay PRU.
FlexWave Prism Remote Unit RF Module Installation Guide Page 45TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE Connectivity3Follow the rules listed below to toggle the Power switch that corresponds to each RF Module to its ON position.•For Dual-Band Dual-Bay RF Modules, use the Power switch for the lower module. For example, to power up a Dual-Bay RF Module in combined bays C+D in a Quad-Bay chassis, turn ON DC Power switch for Mod C; leave the DC Power switch for Mod D OFF.•A Legacy Dual-Bay 40W RF Module uses the Power Supplies in both bays. If the Legacy Dual-Bay 40W RF Module is installed in bays C+D, turn ON the Power switch for Mod C and Mod D.Bay ASeRFModuleAC/DC Powerswitch forPRU chassisDC Power switch for Bay ADC Power switch for Bay BDC Power switch for Bay CDC Power switch for Bay DBay BBay CBay D4Verify that the LEDs for all installed RF Modules (located next to their respective connectors) are green. If any of the RF Module LEDs are not green, verify that each RF Module cable is seated fully in its respective connector. If after checking the cable connections and an LED is not green, contact TE for assistance (see “Contacting TE Connectivity” on page 51).
Page 46 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Close the Remote Unit Door and Solar Shield1Do not slam the door to close it—gently swing the door shut and press it firmly closed. 2Slowly close each door latch in a smooth fluid motion—do not allow the door latches to snap closed. For best results, starting with the top latch and working down to the bottom latch, use a flat-head screwdriver to close each latch as shown below.3Do not slam the Solar Shield to close it—gently swing it shut and press it firmly closed. Solar Shield DoorDoor latchCAUTION! Service personnel must confirm that the perimeter gasket and door-to-door gaskets are in place when closing the Remote Unit doors after servicing.CAUTION! If the PRU door was allowed to snap closed, RF output from an HDM RF Module may be disabled for up to three minutes. Any alarms generated immediately following the opening/closing of the PRU Doors, such as Door Open, RF Power Low, System VSWR Fault, and LPA VSWR Fault, automatically clear once the RF has recovered. If alarms do not clear after three minutes, please contact TE for technical support; see “Contacting TE Connectivity” on page 51.Provision the Prism Remote Unit Refer to the current EMS System Setup and Provisioning Guide for information on configuring the PRU for a FlexWave Prism system.
FlexWave Prism Remote Unit RF Module Installation Guide Page 47TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityFLEXWAVE NOTCH FILTER (FWP-SPRINTFILTER)A FlexWave Notch Filter (FWP-SPRINTFILTER) ships with and is required in installations of the following RF Modules:•20W 800 SMR/ 1900 PCS, Dual RF Module (FWP-441T841MOD)•20W 800 MIMO, Single Bay, with two External Filters (FWP-44MT000MOD).Notch Filter Installation TipsYou install the Notch Filter between the Prism Remote Unit and the antenna to provide protection from spurious emissions in the Public Safety band below 861.35 MHz and the Cellular band above 869.0 MHz. The following are installation tips for the Notch Filter:•You can use the same mounting method to mount the Notch Filter as you used to mount the Remote Unit. •Mount the Notch Filter vertically with the N-type female connectors at the bottom. •There are two Ground lugs on the Notch Filter, which are on the back of the two mounting brackets. Follow local practice to ground the Notch Filter.Figure 25 provides the dimensions required to create a mounting template.16.0 ±.1.70.702.805 .95 .951.002 Locaons5/16-18Ground LugFront ViewSide ViewBack View4.5517.9 ±.14.10 MounngBracket15.938.51MounngBracketFigure 25. Notch Filter Mounting Dimensions
Page 48 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015Figure 26 illustrates how to pole mount the Notch Filter.1.13 3.81InputN-TypeFemaleConnectorOutput N-TypeFemaleConnectorBand must be long enoughto wrap around the poleBoom View ofNotch FilterHose clamp sized forinstallaon requirementMounng BracketNOTE: The 800 Notch Filter isdesigned to accept input from the PRU in either itsOutput or Input port, as well as the feed from the antenna.  Figure 26. Pole Mounting a Notch FilterNotch Filter SpecificationsFrequency Range (MHz) Maximum Emissions (Sprint requirement) per 30 kHz817-824 —< 854  < -76 dBm854-859 < -76 dBm859-861.35 < -76 dBm861.35-861.5 < -56 dBm861.5-861.6 < -42 dBm862-869 —Enclosure Rating IP67RF Connectors N-Type Connector, Female (2)Ground Studs (w/star washer) All ground Studs must accept AWG 6 wireMounting Strap mount (Vertical and Horizontal) on up to 12" pole, or Wall mountSize 15.93" x 8.51" x 4.10"Weight 18 LBSOperational Temperature -25°C to +65°CHumidity ETSI 300-019-1-3 10%-100% CondensingVibration-operation ETSI 300-019-1-4Vibration-transportation ETSI 300-019-1-2
FlexWave Prism Remote Unit RF Module Installation Guide Page 49TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivitySTANDARDS CERTIFICATIONFCCThis equipment complies with the applicable sections of Title 47 CFR Part 15 (Host Unit), Part 22 (800 MHz Cellular), Part 24 (1900 MHz - PCS), Part 90 (800/900 - SMR), and Part 27 (2100 MHz - AWS, 700 MHz -LTE and 2300 MHz - WCS).WARNING. This is NOT a CONSUMER device. It is designated for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express Consent of an FCC Licensee to operate this device. Unauthorized use may result in Significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.ICThis equipment complies with the applicable sections of RSS-131- Zone Enhancers for the Land Mobile Service. The term “IC:” before the radio certification number only signifies that Industry Canada Technical Specifications were met.The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device.Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum composite output from the antenna cannot exceed 1000 Watts ERP (LTE, Cellular and SMR), the antenna cannot exceed 1640 Watts EIRP (PCS and AWS), and the antenna must be permanently installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons.UL/CULThis will be installed in a restricted access location. This equipment complies with Type 4, per UL and CUL 50, Standard for Enclosures for Electrical Equipment. This equipment provides the degree of protection specified by IPX6 as defined in IEC Publication 529.FDA/CDRHThis equipment uses a Class 1 LASER according to FDA/CDRH Rules. This product conforms to all applicable standards of 21 CFR Part 1040.Caution: Modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.EU Harmonized StandardsMeets essential requirements of R&TTE 1999/5/EC. •Article 3.1a—The protection of the health and the safety of the user and any other person, including the objectives with respect to safety requirements contained in Directive 2006/95/EC, but with no voltage limit applying.•Article 3.1b—The protection requirements with respect to electromagnetic compatibility contained in Directive 2004/108/EC.•Article 3.2—In addition, radio equipment shall be so constructed that it effectively uses the spectrum allocated to terrestrial/space radio communication and orbital resources so as to avoid harmful interference.EMC StandardsEN 55022 and EN55024 (CE marked) Safety StandardsThis equipment complies with IEC 60950-1, 2ND Edition + Amendment 1 (CE marked) and with UL 60950-1, 2ND Edition + Amendment 1 (File number E174166) (USA and Canada)
Page 50 FlexWave Prism Remote Unit RF Module Installation Guide©2015 TE Connectivity TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015ACCESSING USER DOCUMENTATION ON THE TE CUSTOMER PORTALYou can access additional user documentation on the TE Customer Portal, as described below.1Click on the following URL link:https://www.te.com/portal/wireless/ (Alternatively, enter the preceding URL into your web browser, and then press ENTER on your keyboard.)2Access to the Customer Portal requires a user account and password. On the Sign In page, do one of the following:•If you have an account, in the Already Registered? Sign In Now panel, enter your Email and Password, and then click Sign In.•If you don’t have an account, under Create an Account, click Register Now and follow the prompts.3On the Wireless Customer Portal home page, in either the Resources or Documents panel, click the Manuals and Data Sheets link.4On the Manuals and Data Sheets page, do the following:aOpen the folder for the product line that corresponds to the document that you want to access.bClick on the title of the manual that you wish to open.c(Optional) Save the PDF to your computer.
FlexWave Prism Remote Unit RF Module Installation Guide Page 51TECP-77-141 Issue 8  •  300001744178 Rev H  •  August 2015 ©2015 TE ConnectivityCONTACTING TE CONNECTIVITYTelephone NumbersSalesAsia Pacific +65-6294-9948France 0800 914032Germany 0180 2232923Italy 0800 782374Spain 900 983291United Kingdom 0800 960236USA or Canada 1-800-366-3891Extension 73000Connectivity Extension 73475Wireless Extension 73476Technical SupportUSA or Canada 1-800-530-9960Elsewhere +1-952-917-0761Online AccessCustomer Portalhttps://www.te.com/portal/wireless/Technical Support for Wireless Productshttp://www.te.com/WirelessSupport