ADRF KOREA ADX-R-743M High Power Remote Unite (Distribute Antenna System) User Manual ADX DAS HRU
ADRF KOREA, Inc. High Power Remote Unite (Distribute Antenna System) ADX DAS HRU
User Manual
ADX DAS HRU User Manual Version 0.3 3116 West Vanowen St. Burbank, CA 91505 Tel: 818-840-8131 Fax: 818-840-8138 www.adrftech.com Advanced RF Technologies, Inc. Information in this document is subject to change without notice. Advanced RF Technologies, Inc. 1996-2013. All rights reserved. Please send comments to: E-Mail: Phone: Fax: info@adrftech.com (818) 840-8131 (800) 313-9345 (818) 840-8138 Address: Advanced RF Technologies, Inc. Attention: Technical Publications Department 3116 Vanowen St. Burbank, CA 91505 USA www.adrftech.com Advanced RF Technologies, Inc. ii Revision History Version 0.1 0.2 Author YH Ko YH Ko Descriptions Date Initial Release Section 9 corrected 10/02/13 04/18/14 Change List Version Change list Advanced RF Technologies, Inc. Contents iii Table of Contents 1. Introduction ......................................................................................................................................................15 1.1 1.2 Highlights ...................................................................................................................................................15 Head End Parts List ....................................................................................................................................16 1.2.1 ADX-H-NMS-PKG Parts List .................................................................................................................16 1.2.2 ADX-H-BCU Parts List ..........................................................................................................................17 1.2.3 ADX-H-RFU Parts List ..........................................................................................................................17 1.2.4 ADX-RACK-ODU Parts List ...................................................................................................................18 1.2.5 ADX-H-ODU4 Parts List .......................................................................................................................18 1.2.6 ADX-H-ODU1 Parts List .......................................................................................................................18 1.3 High Power Remote Unit Parts List ............................................................................................................19 1.3.1 ADX-R-xxx43M (Main HRU) Parts List .................................................................................................19 1.3.2 ADX-R-xxx43M (Main HRU) Parts List .................................................................................................19 1.4 ADX DAS Quick View ..................................................................................................................................20 1.4.1 HE Quick View ....................................................................................................................................20 1.4.3 RU Quick View ....................................................................................................................................21 1.5 2. Warnings and Hazards ...............................................................................................................................22 Block Diagram ...................................................................................................................................................23 2.1 ADX DAS Block Diagram .............................................................................................................................24 2.2 ADX DAS Topology .....................................................................................................................................25 2.3 Configuration .............................................................................................................................................26 2.3.1 Single band or multi-band configuration (1~3 bands) ........................................................................26 2.3.2 Multi-band configuration (4~6 bands) ...............................................................................................27 2.4 3. ADX-DAS Scalability ...................................................................................................................................27 ADX Overview ...................................................................................................................................................29 3.1 Head End ....................................................................................................................................................29 3.1.1 NMS (Network Management System) ................................................................................................30 3.1.1.1 LEDs ..........................................................................................................................................30 3.1.1.2 Ethernet Port ............................................................................................................................31 3.1.1.3 Host/Remote Switch .................................................................................................................31 3.1.1.4 HE View/RU View Switch ..........................................................................................................31 3.1.2 RFU (ADX-H-RFU-x) .............................................................................................................................32 3.1.2.1 LEDs ..........................................................................................................................................32 3.1.2.2 RF Ports .....................................................................................................................................33 3.1.2.3 Communication Port .................................................................................................................33 3.1.3 Channel Combiner (ADX-H-CHC) ........................................................................................................33 3.1.3.1 RF ports .....................................................................................................................................33 3.1.4 Optic Unit (ADX-RACK-ODU, ADX-H-ODU4/ADX-H-ODU1).................................................................34 Advanced RF Technologies, Inc. iv 3.1.4.1 LEDs ..........................................................................................................................................34 3.1.4.2 RF Ports .....................................................................................................................................34 3.1.4.3 Optic Ports ................................................................................................................................35 3.1.4.4 Communication Port .................................................................................................................35 3.1.5 Power Supply Unit (ADX-H-PSU).........................................................................................................35 3.1.5.1 LEDs ..........................................................................................................................................36 3.1.5.2 AC Input On/Off Switch, AC Input Port and AC Input Selection Switch ....................................36 3.1.5.3 Battery Backup Port, Battery Install Port and Battery Backup Switch ......................................36 3.1.6 Optional Band Combiner Unit (ADX-H-BCU-x)....................................................................................37 3.1.6.1 LEDs ..........................................................................................................................................37 3.1.6.2 RF Ports .....................................................................................................................................38 3.1.6.3 Communication Port .................................................................................................................38 3.2 HRU ............................................................................................................................................................38 3.2.1 Port .....................................................................................................................................................38 3.2.1.1 RF Port ......................................................................................................................................38 3.2.1.1.1 Antenna server port (DIN type) ..............................................................................................38 3.2.1.1.2 Extension port (N type) ..........................................................................................................39 3.2.1.2 Optic port..................................................................................................................................39 3.2.1.3 GUI, RS 485 port .......................................................................................................................39 3.2.2 LEDs ....................................................................................................................................................40 3.2.3 AC On/Off Switch, AC Port..................................................................................................................41 4. Cable Connection ..............................................................................................................................................42 4.1 Head End Connection Diagrams ................................................................................................................42 4.1.1 Front/Rear Head End Connection View with Optional BCU unit ........................................................42 4.1.2 Rear Head End Connection View with (4) ADX-RACK-ODU units .......................................................43 4.2 5. High Power Remote Unit Connection Diagrams ........................................................................................44 Mounting method .............................................................................................................................................45 5.1 Head End ....................................................................................................................................................45 5.1.1 Rack Mount ........................................................................................................................................45 5.1.2 Wall Mount .........................................................................................................................................46 5.2 HRU ............................................................................................................................................................47 5.2.1 Wall Mount .........................................................................................................................................47 6. Installation ........................................................................................................................................................47 6.1 6.2 Pre-Installation Inspection .........................................................................................................................47 ADX DAS Installation Procedure ................................................................................................................48 6.2.1 HE Installation Procedure ...................................................................................................................48 6.2.1.1 Installing a ADX DAS HE in a rack ..............................................................................................48 6.2.1.2 Wall mounting the ADX DAS HE................................................................................................50 6.2.2 RU Installation Procedure ...................................................................................................................52 Advanced RF Technologies, Inc. 7. 6.3 Grounding ..................................................................................................................................................54 6.4 Optic Port Cleaning ....................................................................................................................................55 Commissioning ..................................................................................................................................................56 7.1 Pre-Commissioning Check .........................................................................................................................56 7.1.1 Verify cable connections ....................................................................................................................56 7.1.2 Connect to the Web-GUI ....................................................................................................................56 7.1.3 Check Navigation Tree Status .............................................................................................................57 7.1.4 Set Location Info, Installer Info and Date & Time...............................................................................57 7.1.5 Verify Navigation Tree Links ...............................................................................................................57 7.1.6 BOM Comparison & Check Band Configuration .................................................................................58 7.1.7 Lock current navigation tree ..............................................................................................................58 7.2 Commissioning...........................................................................................................................................59 7.2.1 Optic Commissioning ..........................................................................................................................59 7.2.1.1 How to compensate the optic loss ...........................................................................................59 7.2.2 HE Commissioning ..............................................................................................................................61 7.2.2.1 Composite power .....................................................................................................................61 7.2.3 HRU Commissioning ...........................................................................................................................67 7.3 DAS Install Verification ..............................................................................................................................68 7.3.1 Setting SNMP & Remote IP .................................................................................................................68 7.3.2 Verification through Web based GUI .................................................................................................68 7.3.3 UL noise power detection ..................................................................................................................68 8. Web-GUI ...........................................................................................................................................................69 8.1 Web-GUI Setup ..........................................................................................................................................69 8.1.1 DAS system/PC Connection Using Web-GUI ......................................................................................69 8.2 Administrator/User Mode .........................................................................................................................70 8.2.1 Common .............................................................................................................................................70 8.2.1.1 Navigation tree Lock/Unlock ....................................................................................................70 8.2.1.2 Navigation Tree.........................................................................................................................70 8.2.1.3 Power Status .............................................................................................................................71 8.2.1.4 Commissioning Status ...............................................................................................................71 8.2.1.5 Information ...............................................................................................................................71 8.2.2 Status Tab ...........................................................................................................................................72 8.2.2.1 Status – NMS ............................................................................................................................72 8.2.2.2 Status – BCU .............................................................................................................................75 8.2.2.3 Status – RFU ..............................................................................................................................77 8.2.2.4 Status – ODU .............................................................................................................................79 8.2.2.5 Status – HRU Hub...................................................................................................................... 82 8.2.2.6 Status – Remote module ..........................................................................................................83 8.2.3 Control Tab .........................................................................................................................................86 Advanced RF Technologies, Inc. vi 8.2.3.1 Control – NMS .......................................................................................................................... 86 8.2.3.2 Control – BCU ...........................................................................................................................87 8.2.3.3 Control – RFU ............................................................................................................................88 8.2.3.4 Control – ODU ...........................................................................................................................92 8.2.3.5 Control – RH Hub ...................................................................................................................... 93 8.2.3.6 Control – Remote Module (Master or Slave RU) ......................................................................94 8.2.4 Install Tab ...........................................................................................................................................97 8.2.4.1 Install – NMS .............................................................................................................................97 8.2.4.2 Install – BCU ............................................................................................................................100 8.2.4.3 Install – RFU ............................................................................................................................101 8.2.4.4 Install – ODU ...........................................................................................................................103 8.2.4.5 Install – HRU Hub ....................................................................................................................104 8.2.4.6 Install – Remote Module (Master or Slave RU) ......................................................................105 8.2.5 System ..............................................................................................................................................107 8.2.5.1 System: Account .....................................................................................................................107 8.2.5.2 System: Logs ...........................................................................................................................108 8.2.5.3 System: Update.......................................................................................................................109 8.2.5.4 System: System Information ................................................................................................... 110 8.2.5.5 System: Backup/Restore .........................................................................................................111 8.2.5.6 System: SNMP.........................................................................................................................113 8.2.5.7 System: Closeout Package ...................................................................................................... 114 8.2.6 Help ..................................................................................................................................................115 8.2.7 Logout ...............................................................................................................................................115 8.3 9. 10. Guest Mode .............................................................................................................................................115 System-Wide Specification (to be connected to HE via Optic line) ................................................................116 9.1 PCS band ..................................................................................................................................................116 9.2 AWS band ................................................................................................................................................116 9.3 Cellular band ............................................................................................................................................117 9.4 700 band ..................................................................................................................................................118 antenna specifications ....................................................................................................................................119 10.1 Omni Antenna ..........................................................................................................................................119 11. Mechanical Drawing .......................................................................................................................................120 Advanced RF Technologies, Inc. vii Figures Figure 1-1 Figure 1-2 Figure 2-1 Figure 2-2 Figure 2-3 Figure 2-4 Figure 3-1 Figure 3-2 Figure 3-3 Figure 3-4 Figure 3-5 Figure 3-6 Figure 3-7 Figure 3-8 Figure 3-9 Figure 3-10 Figure 3-11 Figure 3-12 Figure 3-13 Figure 3-14 Figure 3-15 Figure 3-16 Figure 3-17 Figure 3-18 Figure 3-19 Figure 3-20 Figure 3-21 Figure 3-22 Figure 3-23 Figure 3-24 Figure 3-25 Figure 3-26 Figure 3-27 Figure 3-28 Figure 3-29 Figure 3-30 Figure 3-31 Figure 4-1 Figure 4-2 Figure 4-3 Figure 4-4 Figure 5-1 Figure 5-2 Figure 5-3 Figure 6-1 Figure 6-2 Figure 6-3 Figure 6-4 Figure 6-5 Figure 6-6 ADX DAS HE Quick View .....................................................................................................................20 ADX DAS HRU Quick View ...................................................................................................................21 ADX DAS Block Diagram (4BANDS) .....................................................................................................24 ADX DAS Topology ..............................................................................................................................25 ADX DAS 3bands Configuration ..........................................................................................................26 ADX DAS 4bands Configuration ..........................................................................................................27 Head End Front View ..........................................................................................................................29 ADX-H-NMS Front View ......................................................................................................................30 NMS LED .............................................................................................................................................30 Ethernet Port ......................................................................................................................................31 Host/Remote Switch ...........................................................................................................................31 HE View/RU View Switch ....................................................................................................................31 RFU Front & Rear View .......................................................................................................................32 RFU LED ..............................................................................................................................................32 Communication Port (RFU) .................................................................................................................33 ADX-H-CHC Front & Rear View ...........................................................................................................33 ADX-RACK-ODU Front & Rear view ....................................................................................................34 ADX-H-ODU4 and ADX-H-ODU1 Installed in ADX-RACK-ODU ............................................................34 ADX-RACK-ODU LED............................................................................................................................34 ODU RF Ports ......................................................................................................................................35 ODU Optic Ports..................................................................................................................................35 Communication Port (ODU) ................................................................................................................35 ADX-H-PSU Front & Rear View ...........................................................................................................35 HE PSU LED .........................................................................................................................................36 HE PSU AC Input On/Off Switch, AC Input Port and AC Input Selection Switch .................................36 Battery Backup Port, Battery Install Port and Battery Backup Switch ................................................36 ADX-H-BCU Front & Rear View ...........................................................................................................37 BCU LED ..............................................................................................................................................37 Communication Port (BCU) ................................................................................................................38 ADX-HRU Single enclosure (bottom view) ..........................................................................................38 Inner Optic port connection ...............................................................................................................39 Optic connection ................................................................................................................................39 ADX-HRU 3bands GUI connection (Single enclosure) .........................................................................40 ADX-HRU 4bands GUI, RS 485 connection (2 enclosures) ..................................................................40 HRU LED ..............................................................................................................................................41 HRU AC Port ........................................................................................................................................41 HRU AC Switch ....................................................................................................................................41 HE Cable connection (1 ADX-RACK-ODU +1 BCU) ..............................................................................43 HE Cable connection (4 ADX-RACK-ODUs).......................................................................................... 43 ADX-HRU 3bands connection (Single enclosure) ................................................................................44 ADX-HRU 4bands connection (2 enclosures) ...................................................................................... 44 HE Rack Mount (Front & Rear view) ...................................................................................................45 HE Wall Mount (Top View) .................................................................................................................46 HRU Wall Mount .................................................................................................................................47 ADX HE 19” Rack Mount Instructions .................................................................................................49 ADX HE Wall Mount Instructions ........................................................................................................50 Wall Mount Instructions for ADX-HE added 1U Unit ..........................................................................51 HRU Wall Mount Instructions .............................................................................................................53 Ground Cable Connection (HE rear side) ............................................................................................54 Ground Cable Connection (HRU dual side) .........................................................................................54 Advanced RF Technologies, Inc. viii Figure 6-7 Figure 6-8 Figure 7-1 Figure 7-2 Figure 7-3 Figure 7-4 Figure 7-5 Figure 7-6 Figure 7-7 Figure 7-8 Figure 8-1 Figure 8-2 Figure 8-3 Figure 8-4 Figure 8-5 Figure 8-6 Figure 8-7 Figure 8-8 Figure 8-9 Figure 8-10 Figure 8-11 Figure 8-12 Figure 8-13 Figure 8-14 Figure 8-15 Figure 8-16 Figure 8-17 Figure 8-18 Figure 8-19 Figure 8-20 Figure 8-21 Figure 8-22 Figure 8-23 Figure 8-24 Figure 8-25 Figure 8-26 Figure 8-27 Figure 8-28 Figure 8-29 Figure 8-30 Figure 8-31 Figure 8-32 Figure 8-33 Figure 8-34 Figure 8-35 Figure 8-36 Figure 8-37 Figure 8-38 Figure 8-39 Figure 8-40 Figure 8-41 Figure 8-42 Figure 8-43 Optic Connector Cleaning (left) and Optic Port Cleaning (right) ........................................................55 SC/APC Optic Connector Dust Cap .....................................................................................................55 Login window......................................................................................................................................56 Navigation tree Lock/Unlock ..............................................................................................................57 Navigation tree ...................................................................................................................................57 ODU Install page .................................................................................................................................59 measured optic loss display ................................................................................................................59 BCU Install Window ............................................................................................................................65 RFU Install Window ............................................................................................................................66 Remote Module Install Window .........................................................................................................67 Login screen ........................................................................................................................................69 Navigation tree Lock/Unlock ..............................................................................................................70 Navigation tree ...................................................................................................................................70 ADX DAS General Information ............................................................................................................71 Status - NMS .......................................................................................................................................72 System Summary ................................................................................................................................72 System scan time, HE view/RU view ...................................................................................................73 HE alarm status ...................................................................................................................................73 HE Commissioning status ...................................................................................................................74 Status – BCU .......................................................................................................................................75 Status – BCU Band ..............................................................................................................................75 Status – BCU Power & Atten ...............................................................................................................75 Status – BCU Power Ratio...................................................................................................................76 Status – BCU Alarm .............................................................................................................................76 Status – RFU ........................................................................................................................................77 Status – RFU Band...............................................................................................................................77 Power & Gain Display (Admin) ...........................................................................................................77 Power & Gain Display (User) ..............................................................................................................78 Status - ODU .......................................................................................................................................79 Summary (Status – ODU) ....................................................................................................................79 RF Status (Status – ODU) ....................................................................................................................80 Optic Status (Status – ODU) ................................................................................................................80 Optic Attenuation (Status – ODU) ......................................................................................................81 Optic Path Status (Status – ODU) .......................................................................................................81 Status - HRU Hub ................................................................................................................................82 RU Alarm Status (Status - HRU Hub) ...................................................................................................82 RU Commissioning Status (Status - HRU Hub) .................................................................................... 82 Status – Remote Module ....................................................................................................................83 PCS Band Information (Status – Remote Module) .............................................................................84 Power & Gain (Admin) ........................................................................................................................84 Power & Gain (User) ...........................................................................................................................84 Optic Power (Status – Master HRU only)............................................................................................85 Control - NMS .....................................................................................................................................86 Heartbeat (Control – NMS) .................................................................................................................86 HE System Reboot & Factory Setting (Control – NMS) .......................................................................86 NMS System Reboot & Factory Setting (Control – NMS) ...................................................................86 Control – BCU .....................................................................................................................................87 Control – BCU Manual ATT Control ....................................................................................................87 Control – BCU Reboot/Factory Setting ...............................................................................................88 Control – BCU Alarm Setting...............................................................................................................88 Control - RFU ......................................................................................................................................88 General Setting (Control – RFU) (Admin)............................................................................................89 General Setting (Control – RFU) (User) ...............................................................................................89 Advanced RF Technologies, Inc. ix Figure 8-44 Figure 8-45 Figure 8-46 Figure 8-47 Figure 8-48 Figure 8-49 Figure 8-50 Figure 8-51 Figure 8-52 Figure 8-53 Figure 8-54 Figure 8-55 Figure 8-56 Figure 8-57 Figure 8-58 Figure 8-59 Figure 8-60 Figure 8-61 Figure 8-62 Figure 8-63 Figure 8-64 Figure 8-65 Figure 8-66 Figure 8-67 Figure 8-68 Figure 8-69 Figure 8-70 Figure 8-71 Figure 8-72 Figure 8-73 Figure 8-74 Figure 8-75 Figure 8-76 Figure 8-77 Figure 8-78 Figure 8-79 Figure 8-80 Figure 8-81 Figure 8-82 Figure 8-83 Figure 8-84 Figure 8-85 Figure 8-86 Figure 8-87 Figure 8-88 Figure 8-89 Figure 8-90 Figure 8-91 Figure 8-92 Figure 8-93 Figure 8-94 Figure 8-95 Figure 8-96 Reboot & Factory Setting (Control – RFU) ..........................................................................................89 UL Noise Detection (Control – RFU) ...................................................................................................89 UL Noise Detection - PCS band ...........................................................................................................90 Manual Attenuator Control Setting (Control – RFU) ..........................................................................90 Alarm Threshold Setting (Control – RFU) ...........................................................................................91 Control – ODU.....................................................................................................................................92 Optic Attenuation – ODU ....................................................................................................................92 Reboot & factory Setting (Control – ODU) .........................................................................................93 Control – HRU Hub .............................................................................................................................93 Reboot & Factory Setting (Control – HRU Hub) ..................................................................................93 Control – Remote Module ..................................................................................................................94 General Setting (Control - RU) ...........................................................................................................94 Reboot & factory Setting (Control - RU) .............................................................................................95 Optic Setting (Control - RU) ................................................................................................................95 Manual Atten Control (Control - RU) ..................................................................................................95 Alarm Setting (Control - RU) ...............................................................................................................96 Install - NMS .......................................................................................................................................97 HE Commissioning Status (Install – NMS) ...........................................................................................97 SNMP (Install – NMS)..........................................................................................................................98 Location Setting (Install – NMS) .........................................................................................................98 External Modem Box Setting (Install – NMS) .....................................................................................98 Description (Install – NMS) .................................................................................................................99 SNMP Agent False Alarm Test (Install – NMS) ....................................................................................99 Location Info / Installer Info (Install – NMS) .......................................................................................99 Date & Time Setting (Install – NMS) .................................................................................................100 Install – BCU ......................................................................................................................................100 Install – BCU Commissioning ............................................................................................................101 Install – BCU Description ..................................................................................................................101 Install - RFU .......................................................................................................................................102 RFU Commissioning (Install – RFU) ...................................................................................................103 Description (Install – RFU) ................................................................................................................103 Install – ODU .....................................................................................................................................103 Optic control (Control – ODU) ..........................................................................................................104 Description (Install – ODU) ...............................................................................................................104 Install-RU Hub ...................................................................................................................................105 RU Commissioning Status (Install-RU Hub) ...................................................................................... 105 Description (Install-RU Hub) .............................................................................................................105 Install-Remote Module .....................................................................................................................106 RU Output Commissioning (Install-RU) ............................................................................................106 Description (Install-Remote Module) ...............................................................................................107 Account Management ......................................................................................................................107 New Account ....................................................................................................................................107 Change Password ..............................................................................................................................108 Event Log ..........................................................................................................................................108 User Log ............................................................................................................................................109 System update ..................................................................................................................................109 Message after System update is complete .......................................................................................110 System Information ..........................................................................................................................110 System Notification ..........................................................................................................................111 Bill of material ..................................................................................................................................111 Setting Backup (Before) ....................................................................................................................112 Setting Backup (After).......................................................................................................................112 Setting Restore .................................................................................................................................113 Advanced RF Technologies, Inc. Figure 8-97 Figure 8-98 Figure 8-99 Figure 8-100 Figure 8-101 Figure 10-1 Figure 10-2 SNMP V1/V2 .....................................................................................................................................113 SNMP V3 ...........................................................................................................................................114 System- Closeout Package ................................................................................................................114 System- Closeout Package after the file upload ...............................................................................114 Help...................................................................................................................................................115 HE Drawing .......................................................................................................................................120 Master HRU Drawing ........................................................................................................................121 Advanced RF Technologies, Inc. xi Tables Table 1-1 Table 1-2 Table 1-3 Table 1-4 Table 1-5 Table 1-6 Table 1-7 Table 1-8 Table 2-1 Table 3-1 Table 3-2 Table 3-3 Table 3-4 Table 3-5 Table 3-6 Table 7-1 Table 7-2 Table 7-3 Table 7-4 Table 7-5 Table 7-6 Table 7-7 Table 7-8 Table 7-9 Table 7-10 Table 8-1 Table 8-2 Table 8-3 Table 8-4 Table 8-5 Table 8-6 Table 8-7 Table 8-8 Table 8-9 Table 8-10 Table 8-11 Table 8-12 Table 8-13 Table 8-14 Table 8-15 Table 8-16 Table 8-17 Table 8-18 Table 8-19 Table 8-20 Table 8-21 Table 8-22 Table 8-23 ADX-H-NMS Parts List .........................................................................................................................16 ADX-H-BCU Parts List ..........................................................................................................................17 ADX-H-RFU Parts List ..........................................................................................................................17 ADX-RACK-ODU Parts List ...................................................................................................................18 ADX-H-ODU4 Parts List .......................................................................................................................18 ADX-H-ODU1 Parts List .......................................................................................................................18 Main HRU Parts List ............................................................................................................................19 Extended HRU Parts List .....................................................................................................................19 ADX-DAS Scalability ............................................................................................................................27 NMS LED Specifications ......................................................................................................................30 RFU LED Specifications .......................................................................................................................32 ODU LED Specifications ......................................................................................................................34 HE PSU LED Specifications ..................................................................................................................36 BCU LED Specifications .......................................................................................................................37 Master HRU LED Specifications ..........................................................................................................41 Optic loss compensation table ...........................................................................................................60 Back-off value for each technology due to traffic breathing ..............................................................61 Input signal conditions @HE RFU downlink input ..............................................................................62 HE maximum downlink input level without 10dB attenuator ............................................................62 HE downlink input signal conditions after adding 10dB attenuator to HE downlink input port ........62 HE maximum downlink input level after adding 10dB attenuator to HE downlink input port ..........63 Input signal conditions @HE BCU downlink input ..............................................................................63 HE maximum downlink input level .....................................................................................................63 Targeted maximum input power ........................................................................................................63 Maximum Output Power per carrier ..................................................................................................64 Account Information for Login ...........................................................................................................69 Navigation tree ...................................................................................................................................70 Power Supply Status ...........................................................................................................................71 Commissioning ICON ..........................................................................................................................71 System Summary Description .............................................................................................................73 Description for HE Commissioning status...........................................................................................74 Description for NMS alarm .................................................................................................................74 RFU Alarm Status ................................................................................................................................78 Summary Description .........................................................................................................................80 Description for optic path status ........................................................................................................81 Description for HRU Commissioning status ........................................................................................83 Alarm Status (Status - HRU Hub) ........................................................................................................83 Operating Status (Status – Remote Module) ......................................................................................85 Description for General Setting ..........................................................................................................89 Description for Main Gain Control Setting (Control – RFU) ................................................................90 Description for Alarm Threshold Setting (Control – RFU)...................................................................91 Description for Optic Attenuation (Control – ODU) ...........................................................................93 Description for General Setting (Control - RU) ...................................................................................94 Description for Optic Setting (Control - RU) .......................................................................................95 Description for Manual Atten Control (Control - RU) .........................................................................96 Description for HE Commissioning Status (Install – NMS) ..................................................................97 Description for Optic control (Control – ODU) .................................................................................104 Description for HRU Commissioning status ......................................................................................105 Advanced RF Technologies, Inc. xii Advanced RF Technologies, Inc. xiii Terms and Abbreviations The following is a list of abbreviations and terms used throughout this document. Abbreviation/Term AGC ALC AROMS BCU BTS CDMA CHC CW DAS DL Downlink HE HPA HW IF LNA LTE MS NMS ODU OEU PLL PSU RF RFU RU HRU Remote Module SW UL Uplink VSWR Definition Automatic Gain Control Automatic Level Control ADRF’ Repeater Operation and Management System Band Combiner Unit Base Transceiver Station Code Division Multiple Access Channel combiner Continuous Wave (un-modulated signal) Distributed Antenna System Downlink The path covered from the Base Transceiver Station (BTS) to the subscribers’ service area via the repeater Head End High Power Amplifier Hardware Intermediate Frequency Low Noise Amplifier Long Term Evolution Mobile Station Network Management System Optic Distribution Unit which is located in ADX-RACK-ODU. An ADX-RACK-ODU has two ODUs. Optic Expansion Unit Phased Locked Loop Power Supply Unit Radio Frequency RF Channel Unit Remote Unit which is composed of master HRU and multiple slaves RU High Power RU generic term for master HRU and Master RU, slave RU Software Uplink The path covered from the subscribers’ service area to the Base Transceiver Station (BTS) via the repeater Voltage Standing Wave Ratio Advanced RF Technologies, Inc. 14 1. INTRODUCTION Up to (8) frequency bands in one body: Currently the ADX supports 700 MHz (Lower A, Lower B, Lower C, and Upper C), 700MHz Public Safety w/ Upper D support, Cellular, PCS, SMR800/SMR900, and AWS bands. 1.1 Highlights Modular Structure (HE) Supports multi bands service (700MHz, 700MHz PS, Cell, PCS, AWS, SMR800/SMR900 etc.) in one body Supports up to 8 RF units Supports optional combining/balancing of multiple carriers’ signals via BCU (Band Combiner Unit) Supports up to a of maximum of 32 Remote Units Tri band per HRU enclosure 43dBm of downlink composite output power Requires only single strand of fiber per remote unit Operates with up to 5dBo optical loss (with ADX-H-ODU4, single mode), up to 10dBo optical loss possible(with ADX-H-ODU1, single mode) Supports SNMP v1, v2, v3 (get, set & traps) Web-based GUI Interface; No 3rd party GUI software required Web-GUI connectivity via DHCP in host mode Versatility and Usability: ADX gives total control to the user. Control parameters such as gain, output power, and alarm threshold can be changed using Web-GUI interface allowing the user to fine tune the system to the given RF environment. Uplink noise measurement routine Support RU View mode, refer to section 3.1.1.4 Incremental Automatic Shutdown/Resume Time: ADX gradually increases the time span between automatic shutdown and resume period before it permanently shuts itself down Support ALC function to prevent ADX DAS from input overload or output overpower Advanced RF Technologies, Inc. 15 1.2 Head End Parts List 1.2.1 ADX-H-NMS-PKG Parts List Table 1-1 Label ADX-H-NMS Parts List Quantity Description 28 ADX-H-NMS-PKG (Network Management System Package) ADX-H-NMS ADX-H-PSU (AC to DC Supply) ADX-H-CHC (Head End Channel Combiner) AC Power Cord RJ-45 Crossover Cable Ground Cable Documentation CD (User Manual, Quick Start Guide and Troubleshooting Guide) Wall Anchor Bolt Set SMA terminators L-mounting Brace A. B. C. D. G. Advanced RF Technologies, Inc. E. H. 16 F. 1.2.2 ADX-H-BCU Parts List Table 1-2 ADX-H-BCU Parts List Label Quantity Description ADX-H-BCU (Band Combiner Unit) N-Type terminators NM to NM RF Jumper Cables (3ft) Data/Power Cable Chassis mounting brace A. B. 1.2.3 C. D. ADX-H-RFU Parts List Table 1-3 ADX-H-RFU Parts List Label Quantity Description ADX-H-RFU (RF Unit) N-Type Terminators SMA Male RF Jumper Cables A. Advanced RF Technologies, Inc. B. C. 17 E. 1.2.4 ADX-RACK-ODU Parts List Table 1-4 ADX-RACK-ODU Parts List Label Quantity Description ADX-RACK-ODU Data/Power Cable Chassis Mounting Brace ADX-RACK-ODU POWER LD FAIL LINK1 LINK2 LINK3 LINK4 LD FAIL ODU1 LINK1 LINK2 LINK3 LINK4 ODU2 A. B. 1.2.5 C. ADX-H-ODU4 Parts List Table 1-5 ADX-H-ODU4 Parts List Label Quantity Description ADX-H-ODU4 (4-port Optical Unit) SMA-M Terminators SMA-M to SMA-M RF Jumper Cable (3ft) VHF UL UL OUT VHF DL DL IN ADX-H-ODU-4 A. B. 1.2.6 LINK 4 LINK 3 LINK 2 LINK 1 C. ADX-H-ODU1 Parts List Table 1-6 ADX-H-ODU1 Parts List Label Quantity Description ADX-H-ODU1 (1-port Optical Unit) SMA-M Terminators SMA-M to SMA-M RF Jumper Cable (3ft) VHF UL UL OUT VHF DL DL IN ADX-H-ODU-1 A. Advanced RF Technologies, Inc. LINK 1 18 B. C. 1.3 High Power Remote Unit Parts List 1.3.1 ADX-R-xxx43M (Main HRU) Parts List Table 1-7 1.3.2 Main HRU Parts List Label Quantity Description ADX-R-xxx43M (Main HRU) N type-M terminators USB Cable AC cable Ground cable Anchor Bolt Manual CD Install guide Wall mount template ADX-R-xxx43M (Main HRU) Parts List Table 1-8 Extended HRU Parts List Label Quantity Description ADX-R-xxx43E (Extended HRU) N type-M terminators RF cable 6ft USB cable Crossover Ethernet cable 6ft AC cable Ground cable Anchor Bolt Manual CD Install guide Wall mount template Advanced RF Technologies, Inc. 19 1.4 ADX DAS Quick View 1.4.1 HE Quick View ADX-H-BCU-X POWER ADX-RACK-ODU POWER 1.4.2 SOFT FAIL Band Combiner Unit (BCU) Optic Unit (ODU) 19” rack mount Holes LD FAIL LINK1 LINK2 LINK3 LINK4 LD FAIL LINK1 ODU1 Channel Combiner (CHC) LINK2 LINK3 LINK4 ODU2 UL1 UL2 UL3 UL4 UL5 UL6 UL7 UL8 DL1 DL2 DL3 DL4 DL5 DL6 DL7 DL8 ADX-H-CHC ADX-H-RFU-7 POWER DL OUT SOFT FAIL SOFT FAIL SOFT FAIL HARD FAIL HARD FAIL HARD FAIL DL SIG LOW DL SIG LOW DL SIG LOW IL FA IL -H ST FA ER LO FA IL -R PO FA IL -H ER SO FT PO SO FT ADX-H-NMS NMS Unit TT ADX-H-PSU Power Supply Unit (PSU) IL UL IN FA DL OUT RF Channel Unit (RFU) ADX-H-RFU-A POWER UL IN FA IL LIN -R FA IL -H LIN FA IL -R POWER DL OUT HOST Host / Remote Switch, HE view/RU view Switch & RJ-45 port HE VIEW ADX-H-RFU-P UL IN REMOTE RU VIEW CH3 CH2 CH1 BCU Sum Port SUM BAND COM DL IN 3 DPX 3 UL OUT 3 VHF UL 2 UL OUT 2 DL IN 2 VHF DL 2 DPX 2 UL OUT 2 DL IN 1 DPX 1 DL IN 2 UL OUT 1 VHF UL 1 DL OUT UL OUT 1 VHF DL 1 RF Ports connected to CHC UL IN DL IN 1 OPT Optic Ports LINK 8 LINK 7 LINK 6 LINK 5 LINK 4 LINK 3 LINK 2 UL8 UL7 UL6 UL5 UL4 UL3 UL2 UL1 DL8 DL7 DL6 DL5 DL4 DL3 DL2 DL1 LINK 1 RF Ports connected to ODU DL IN UL OUT DPX DL IN UL OUT DL IN DPX ADX-H-RFU-A UL OUT DL IN DPX ADX-H-RFU-C UL OUT DPX ADX-H-RFU-7 ADX-H-RFU-P RFU Simplex Port RFU Duplex Port Battery Backup Port Battery Backup On/Off Switch BATTERY OFF S/W ON OPT 1 OPT 2 OPT 3 OPT 4 BAND COM 1 BAND COM 2 AUX_CH 1 BAND COM 3 BAND COM 4 AUX_CH 2 AC Input & On/Off Switch OFF ODU Interface Ports BATTERY 24V 1A BCU Interface Ports BATTERY INSTALL AC SELECT Ground terminal OFF/ON AC Input Voltage Selection Switch (110V/220V) AUX CH Interface Ports Figure 1-1 Advanced RF Technologies, Inc. AC IN ADX DAS HE Quick View 20 1.4.3 RU Quick View Controller per band RAU Duplexer HPA ORU RCU Optic port PSU Splitter Unit reserve port RF extension port for additional band PCS_A_ SERVER AWS_A_ SERVER 700LTE_A_ SERVER DL_A UL_A DL_B UL_B Server antenna port GUI_A Local GUI port GUI_B RS-485_A POWER OPTIC_A Optic port OPTIC_B AC IN 110V hGdGhjs iGdGhju jGdGmUn AC port RS-485_B RS-485 port for additional band RS-485 port for reserve Ground terminal Fan unit Figure 1-2 Advanced RF Technologies, Inc. ADX DAS HRU Quick View 21 1.5 Warnings and Hazards WARNING! ELECTRIC SHOCK Opening the ADX DAS could result in electric shock and may cause severe injury. WARNING! EXPOSURE TO RF Working with the ADX DAS while in operation, may expose the technician to RF electromagnetic fields that exceed FCC rules for human exposure. Visit the FCC website at www.fcc.gov/oet/rfsafety to learn more about the effects of exposure to RF electromagnetic fields. RF EXPOSURE & ANTENNA PLACEMENT Guidelines Actual separation distance is determined upon gain of antenna used. Please maintain a minimum safe distance of at least 100cm while operating near the donor and the server antennas. Also, the donor antenna needs to be mounted outdoors on a permanent structure. WARRANTY Opening or tampering the ADX DAS will void all warranties. Advanced RF Technologies, Inc. 22 ָ֦ [Y1]: ܹࢽ 50Æ100cm 2014/05/29 FCC Part 15 Class A NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. Laser Safety Fiber optic ports of the ADX DAS emit invisible laser radiation at the 1310, 1550nm wavelength window. To avoid eye injury never look directly into the optical ports, patch cords or optical cables. Do not stare into beam or view directly with optical instruments. Always assume optical output is on. Only technicians familiar with fiber optic safety practices and procedures should perform optical fiber connections and disconnections of the ADX DAS and the associated cables. The ADX DAS complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No.50 (July26. 2001)@IEC 60825-1, Amendment2 (Jan. 2001). Care of Fiber Optic Connectors Do not remove the protective covers on the fiber optic connectors until a connection is ready to be made. Do not leave connectors uncovered when not connected. The tip of the fiber optic connectors should not come into contact with any object or dust. Refer to the cleaning procedure for information on the cleaning of the fiber tip. 2. BLOCK DIAGRAM Advanced RF Technologies, Inc. 23 2.1 ADX DAS Block Diagram AWS BTS { j y { j y PCS Combiner { j y |s { j y |s { j y |s AWS RFU ks ks jGj vTo |s DL IN V/UHF(136~512) SMR800 BTS |s { j y |s { j y |s 700M RFU 4:1 2:1 ks { j y DL IN V/UHF(136~512) DL IN (698~2690) UL OUT V/UHF(136~512) vTo vTo vTo 4:1 ks +( 4:1 SMR900 RFU 4:1 2:1 2:1 ks 4:1 SMR800 RFU vk|JY UL OUT (698~2690) ks SMR900 BTS PCS BTS vk|JX UL OUT (698~2690) 2:1 Cellular RFU UL OUT V/UHF(136~512) 4:1 700M BTS DL IN (698~2690) ks 4:1 PCS RFU CELL BTS 4:1 PCS BTS 2SWLRQDO &RPELQHU 0$,1B+58 (;7(16,21B+58 Reserved Reserved 2W PCS vy| 4W 4W 2W AWS 700M 4W 2W 4W COM 4W CELL 4W 4W 2W vy| wz| BRS 4W SMR WI-FI wz| tptvG hu{ RAU HPA Reserved #1 HRU (PCS) Duplexer PCS HPA RAU AWS #2 HRU (AWS) Duplexer COM 700M RAU HPA CELL BRS #3 HRU (700) Duplexer SMR WI-FI Figure 2-1 Advanced RF Technologies, Inc. ADX DAS Block Diagram (4BANDS) 24 HPA RAU Reserved Duplexer #4 HRU (CELL) 2.2 ADX DAS Topology HE(Head End Unit) BCU(optional) PCS RFU Service Carrier #2 (Band Combiner Unit with BTS or BDA) (RF Interface Unit with BTS or BDA) Service Carrier #3 RU(Remote Unit) PCS Master RU Cellular Slave RU AWS Slave RU OPT-H (RF to Optical) Cellular RFU Service Carrier #1 (RF Interface Unit with BTS or BDA) OPT-H Combiner Service Carrier #1 700M Slave RU (RF to Optical) CHC-H AWS RFU Service Carrier #2 700M RFU Service Carrier #2 (RF to Optical) PCS Master RU Cellular Slave RU AWS Slave RU OPT-H 700M Slave RU OPT-H Combiner (HE Channel Combiner) (RF Interface Unit with BTS or BDA) (RF to Optical) (RF Interface Unit with BTS or BDA) Combiner PCS Master RU Cellular Slave RU AWS Slave RU RF Optic 700M Slave RU (Optic Expansion Unit) PCS Master RU Cellular Slave RU AWS Slave RU Combiner OEU 700M Slave RU Combiner PCS Master RU Cellular Slave RU AWS Slave RU 700M Slave RU 700M Slave RU Figure 2-2 Advanced RF Technologies, Inc. ADX DAS Topology 25 Combiner PCS Master RU Cellular Slave RU AWS Slave RU 2.3 Configuration 2.3.1 Single band or multi-band configuration (1~3 bands) Figure 2-3 ADX DAS 3bands Configuration HRU is composed of only Main HRU for 1~3 bands configuration In this case, Main HRU has single ORU. Advanced RF Technologies, Inc. 26 2.3.2 Multi-band configuration (4~6 bands) Figure 2-4 ADX DAS 4bands Configuration HRU is composed of Main HRU and Extended HRU for 4~6 bands In this case, Main HRU has single ORU. 2 RF cables needed between Main HRU and Extended HRU 1 communication cable needed between Main HRU and Extended HRU 2.4 ADX-DAS Scalability Table 2-1 Unit Scalability Supported band 700M, Cellular, AWS 1W/2W, PCS 1W/2W, SMR800/900, PS700 RFU HE ADX-DAS Scalability NMS Optic Unit Up to 4 Band Combiner Unit Power Supply Unit (AC or DC) RU or HRU Up to 4 OEU PSU (RU) up to 6: card type th th 7 & 8 RFU: 19” rack type Up to 8 Channel Combiner RU or HRU Remarks To support multiple carriers Capable of supplying power to 8 RFUs, 4 BCUs, 4 ODU racks and NMS. Up to 60 Up to 4 Adaptor type 1 per remote module 19” rack mount Advanced RF Technologies, Inc. Capable of supplying power to 8 Remote 27 (AC or DC) Advanced RF Technologies, Inc. Modules 28 3. ADX OVERVIEW 3.1 Head End Head end components include: ADX-H-NMS (Network Management System) ADX-H-CHC (Head End Channel Combiner) ADX-H-PSU (Head End Power Supply) Up to [4] ADX-H-BCU (Band Combiner Unit) Up to [8] ADX-H-RFU-x (RF Unit) Up to [4] ADX-RACK-ODU (Optical Unit) Specifications Size: 19.0 x 14.6 x 12.2 inches (482 x 370 x 311 mm) Weight: 83.7 lbs (38.0 Kg)@4 RFU, CHC-H, PSU and NMS Power Consumption: 52W@4 RFU, 1 ADX-H-ODU4 and NMS, 28W@1 RFU, 1 ADX-H-ODU4 and NMS Power Input: 110VAC or -48VDC(optional) Supports the ADRF-BBU for external battery backup solution ADX-H-BCU-P POWER ADX-H-RACK-ODU POWER LD FAIL1-4 LINK1 UL1 SOFT FAIL LINK2 LINK3 UL2 UL3 UL4 DL2 DL3 DL4 LINK4 LD FAIL5-8 LINK5 LINK6 LINK7 LINK8 UL5 UL6 UL7 UL8 DL5 DL6 DL7 DL8 ADX-H-CHC DL1 ADX-H-RFU-P ADX-H-RFU-7 POWER DL OUT POWER UL IN DL OUT ADX-H-RFU-A POWER UL IN POWER DL OUT UL IN DL OUT SOFT FAIL SOFT FAIL SOFT FAIL SOFT FAIL HARD FAIL HARD FAIL HARD FAIL HARD FAIL DL SIG LOW DL SIG LOW DL SIG LOW DL SIG LOW IL FA IL ST ER FA IL -R FA IL -H FA IL LIN -R FA IL -H LIN FA IL -R HOST HE VIEW FT FT FA SO ER IL -H ADX-H-NMS SO LO PO TT ADX-H-PSU FA UL IN ADX-H-RFU-C PO REMOTE RU VIEW Figure 3-1 Advanced RF Technologies, Inc. Head End Front View 29 3.1.1 Supports SNMP v1, v2, and v3 (get, set & trap) and web-based GUI Interface. Monitors alarms and status Provides control interfaces with all subordinate modules Provides overall DAS structure via the auto tree update function Size: 19.0 x 12.1 x 1.7 inches Weight: 5.5 lbs IL -R FA IL -R FA IL -H FA HE VIEW NK FA IL -H FA IL -H HOST LI LI NK HA RD PO SO FT ER ADX-H-NMS FA IL -R Spec SO FT Functions and features HA RD NMS (Network Management System) REMOTE RU VIEW Figure 3-2 ADX-H-NMS Front View 3.1.1.1 LEDs SOFT FAIL-H SOFT FAIL-R HARD FAIL-H HARD FAIL-R LINK FAIL-H LINK FAIL-R Solid Green OFF Solid Yellow Solid Green Solid Yellow Solid Green Solid Red Solid Green Solid Red Solid Green Solid Yellow Solid Green Solid Yellow Solid Green Advanced RF Technologies, Inc. -R LI FA FA IL IL LAI -F LI AR NMS LED NMS LED Specifications ADX DAS-NMS Power -H -F Figure 3-3 Table 3-1 LAI LAR SO FT -F AI AI -F FT PO SO ER L- NMS has LEDs on the front panel as shown in Figure 3-3. Specifications NMS power is ON NMS power is OFF HE Soft Fail alarm exists in the system No HE Soft Fail alarms are present in the system RU Soft Fail alarm exists in the system No HRU Soft Fail alarms are present in the system HE Hard Fail alarm exists in the system No HE Hard Fail alarms are present in the system RU Hard Fail alarm exists in the system No HRU Hard Fail alarms are present in the system HE Link Fail alarm exists in the system No HE Link Fail alarms are present in the system RU Link Fail alarm exists in the system No HRU Link Fail alarms are present in the system 30 3.1.1.2 Ethernet Port The Ethernet port can be used to communicate directly with the ADX DAS using a RJ-45 crossover cable or can also be used to connect the ADX DAS to an external modem box. HOST HE VIEW REMOTE RU VIEW Figure 3-4 Ethernet Port 3.1.1.3 Host/Remote Switch The Host/Remote Switch allows the user to switch the default Repeater IP, Subnet Mask, and Gateway of the repeater to an alternative setup. These settings can be adjusted by logging into the ADX DAS in HOST mode and configuring the settings under the Modem Box Setting section under the Install Page of NMS. Once the settings are set, flipping the switch to the REMOTE position will reboot NMS module with the new alternate settings. Please note that when the NMS is set to the REMOTE position, DHCP is disabled and the NMS will not automatically assign an IP address to any device that connects directly to the NMS. HOST HE VIEW REMOTE RU VIEW Figure 3-5 Host/Remote Switch Host IP: 192.168.63.1 (Fixed IP, unable to modify this IP address) Remote IP: 192.168.63.5 (Default IP, but can be modified in Host mode) 3.1.1.4 HE View/RU View Switch The HE View/RU View Switch allows the user to disable the periodic monitoring performed by the NMS. In the HE view mode, the NMS monitors the status of all subordinate units connected to NMS but when switched to HRU view the NMS does not monitor the subordinate units. HRU View mode will allow the user to go to a HRU and monitor/control the HE. If the NMS is set to the HE View mode and tries to connect to a HRU to monitor the HE, data collisions between the NMS and HRU may prevent the user from properly monitoring or configuring the HE when at the RU. HOST HE VIEW REMOTE RU VIEW Figure 3-6 Advanced RF Technologies, Inc. HE View/RU View Switch 31 3.1.2 RFU (ADX-H-RFU-x) ADX-H-RFU-P ksGpu |sGv|{ POWER UL IN DL OUT SOFT FAIL HARD FAIL kw DL SIG LOW ADX-H-RFU-P Figure 3-7 Functions and features RFU Front & Rear View Provide RF interface with BTS Each RFU has independent gain control and filtering Modular type and hot swappable Supports duplex port or simplex TX & RX ports Easily support additional frequency bands by adding a single RFU Reduces complexity and overall equipment size Specifications Size: 12.8 x 6.2 x 2.8 inches Weight: 7.3 lbs 3.1.2.1 LEDs RFU has LEDs on the front panel as shown in Figure 3-8. POWER SOFT FAIL HARD FAIL DL SIG LOW Figure 3-8 Table 3-2 RFU LED RFU LED Specifications ADX DAS-Module Power Soft Fail Hard Fail DL SIG LOW Solid Green OFF Solid Yellow Solid Green Solid Red Solid Green Solid Yellow Solid Green Advanced RF Technologies, Inc. Specifications Module power is ON. Module power is OFF. Soft Fail alarm exists in the RFU. No Soft Fail alarms are present in the RFU. Hard Fail alarm exists in the RFU. No Hard Fail alarms are present in the RFU. When DL input signal level is lower than the defined threshold level. (default threshold value: -5dBm) When DL input signal level is upper than the defined threshold level. 32 3.1.2.2 RF Ports 3.1.2.2.1 DL IN/UL OUT & DPX ports DL IN/UL OUT & DPX Ports (refer to Figure 3-7) are located at the back of RFU and can be connected directly to the BTS. The RFU can support incoming signal strength from 0 to 25dBm. 3.1.2.2.2 DL OUT/UL IN DL OUT/UL IN Ports (refer to Figure 3-7) are located at the front of the RFU and connect directly to the HE Channel Combiner (ADX-H-CHC). 3.1.2.3 Communication Port The ADX-H-NMS monitors and controls the RFU via this port. DC Power is also provided to the RFU via this port. Figure 3-9 3.1.3 Communication Port (RFU) Channel Combiner (ADX-H-CHC) UL1 UL2 UL3 UL4 UL5 UL6 UL7 UL8 DL1 DL2 DL3 DL4 DL5 DL6 DL7 DL8 ADX-H-CHC UL8 UL7 UL6 UL5 UL4 UL3 UL2 UL1 DL8 DL7 DL6 DL5 DL4 DL3 DL2 DL1 Figure 3-10 ADX-H-CHC Front & Rear View Functions & Features Combines DL signals received from each RFU and feeds the combined signals to the ADX-RACKODU Combines UL signals received from each HRU and feeds the combined signal to the ADX-H-RFU Supports up to 8 RFUs and (4) ADX-RACK-ODU Specifications Size: 16.9 x 12.9 x 1.7 inches Weight: 11.0 lbs 3.1.3.1 RF ports 3.1.3.1.1 RF ports at the front panel (DL 1 to DL 8, UL 1 to UL 8) DL 1(to DL 8) & UL 1(to UL 8) RF ports are connected to DL OUT/UL IN Ports at the front panel of RFU. Receive the downlink signal from each RFU Split the uplink signal received from ODU to each RFU 3.1.3.1.2 RF ports at the back panel (DL 1 to DL 8, UL 1 to UL 8) DL 1(to DL 8) & UL 1(to UL 8) RF ports are connected to DL IN/UL OUT Ports at the back panel of ODU. Transfer the combined downlink signals to ODU Receive the uplink signal from ODU Advanced RF Technologies, Inc. 33 3.1.4 Optic Unit (ADX-RACK-ODU, ADX-H-ODU4/ADX-H-ODU1) ADX-RACK-ODU POWER LD FAIL LINK1 LINK2 LINK3 LINK4 LD FAIL LINK1 ODU1 LINK2 LINK3 LINK4 ODU2 OPT Figure 3-11 VHF UL UL OUT VHF DL ADX-RACK-ODU Front & Rear view DL IN VHF UL LINK 4 LINK 3 Figure 3-12 VHF DL DL IN LINK 2 LINK 1 LINK 4 LINK 3 LINK 2 LINK LINK11 ADX-H-ODU4 and ADX-H-ODU1 Installed in ADX-RACK-ODU Functions & Features Converts signal from RF to optic and transports signals up to a maximum of 10Km (optical 5dBo loss including optical connection loss). ADX-H-ODU4 can supports up to (4) Main HRUs and up to 5dBo optical loss. ADX-H-ODU1 can supports up to 10dBo optical loss. Minimizes the number of optic fiber cable need by transporting multi band signals over a single strand of fiber using WDM technology. UL OUT ADX-H-ODU-4 ADX-H-ODU-1 OPT ADX-H-ODU-4 Spec Size: 19.0 x 12.9 x 1.7 inches (482 x 327 x 44 mm) Weight: 13.2 lbs (6.0 kg) 3.1.4.1 LEDs The ADX-RACK-ODU has the following LEDs on the front panel as shown in Figure 3-13. Figure 3-13 ADX-RACK-ODU LED Table 3-3 ODU LED Specifications ADX DAS-Module Power LD FAIL LINK1 to LINK4 Solid Green OFF OFF Solid Yellow Solid Green Solid Yellow Solid Green Specifications Module power is ON Module power is OFF ODU is not installed LD Fail alarm exists in the ODU No LD Fail alarm is present in the ODU PD Fail alarm exists No PD Fail alarm is present 3.1.4.2 RF Ports VHF UL 1 Advanced RF Technologies, Inc. UL OUT 1 VHF DL 1 34 DL IN 1 Figure 3-14 ODU RF Ports 3.1.4.2.1 DL IN/UL OUT The combined downlink signal received from ADX-H-CHC is transferred to the DL IN 1(or 2) at the back of ODU. The UL OUT port connects any of the ports on back of the ADX-H-CHC labeled UL 1 ~8. 3.1.4.2.2 VHF DL/VHF UL VHF DL/UHF UL ports are used to support Public Safety in the VHF & UHF frequency bands. VHF/UHF signals for Public Safety bypass the ADX-H-CHC and connect directly to the VHF DL/UHF UL ports of the ADX-H-ODU. 3.1.4.3 Optic Ports LINK 4 LINK 3 LINK 2 LINK 1 Figure 3-15 ODU Optic Ports The ADX-H-ODU4 has (4) optic ports and can support up to (4) Main HRU’s. Likewise, the ADX-H-ODU1 has (1) optic ports and can support up to (1) Main HRU. 3.1.4.4 Communication Port ADX-H-NMS monitors and controls the ADX-RACK-ODU via this port. DC power is provided from the ADX-HPSU to the ADX-RACK-ODU via this port. OPT Figure 3-16 Communication Port (ODU) Power Supply Unit (ADX-H-PSU) IL FA IL FA ST ER LO PO TT ADX-H-PSU 3.1.5 OFF Figure 3-17 ADX-H-PSU Front & Rear View Functions & Features Capable of supporting up to: (8) ADX-H-RFUs (4) ADX-H-BCU (4) ADX-H-ODU ADX-H-NMS Support the ADRF-BBU for an external battery backup solution Specificaitons Size: 16.9 x 13.1 x 1.7 inches Weight: 7.7lbs Power Input: 110V or 220VAC, selectable by switch Advanced RF Technologies, Inc. 35 3.1.5.1 LEDs FA IL TT IL FA AC ST BA LO PO ER ADX-H-PSU has the following LEDs on the front panel as shown in Figure 3-18. Figure 3-18 HE PSU LED Table 3-4 HE PSU LED Specifications ADX DAS-Module Power CHG STS LOW BATT AC FAIL DC FAIL Specifications Solid Green OFF Solid Yellow Blinking Green Solid Green OFF Solid Yellow Solid Green Solid Yellow Solid Green Solid Yellow Solid Green ADX-H-PSU power is ON ADX-H-PSU power is OFF No AC power is available and ADRF-BBU is being used PSU is charging the ADRF-BBU ADRF-BBU is completely charged Battery is not connected Low Battery alarm exist in the PSU No Low Battery alarm is present in the PSU AC Fail alarm exists in the PSU No AC Fail alarm is present in the PSU DC Fail alarm exists in the RFU No DC Fail alarms is present in the PSU 3.1.5.2 AC Input On/Off Switch, AC Input Port and AC Input Selection Switch AC IN ON/OFF AC SELECT Figure 3-19 HE PSU AC Input On/Off Switch, AC Input Port and AC Input Selection Switch The AC Power on/off switch is located at the back panel of HE PSU. The ADX-H-PSU can operate at 110V AC and 220V AC. The user should verify that the AC input voltage switch is set to the correct voltage before powering on the ADX-H-PSU. 3.1.5.3 Battery Backup Port, Battery Install Port and Battery Backup Switch OFF OFF BATTERY 24V 1A BATTERY S/W ON BATTERY INSTALL Figure 3-20 Battery Backup Port, Battery Install Port and Battery Backup Switch The Battery Switch can be used to provide power to the optional External Backup Battery (ADRF-BBU) (Figure 3-20). Advanced RF Technologies, Inc. 36 The ADX-H-PSU can be connected to an ADRF-BBU (ADRF Battery Backup Unit) which can provide power during a power outage. If an ADRF-BBU is utilized, connect the ADRF-BBU to the ADX-H-PSU via the external battery backup port as shown in Figure 3-20. (WARNING: The circuit switch on the ADRF-BBU must be set to the OFF position before connecting the ADRFBBU to the ADX-H-PSU to prevent damage to the ADX-H-PSU or the ADRF-BBU and personal injury.) Note: Please contact ADRF Technical Support for assistance if you are unfamiliar with the installation procedure of our battery box. The Battery Install port is used to let ADX-H-NMS know if an ADRF-BBU is connected to the ADX-H-PSU or not. If an ADRF-BBU is connected without the cable connection to Battery Install port, the ADX-H-NMS will not detect the ADRF-BBU. The procedure for connecting HE PSU to BBU 3.1.6 BATT S/W OFF Connect ADRF-BBU to HE PSU Battery port and Battery Install port using HE battery cable BATT S/W ON Optional Band Combiner Unit (ADX-H-BCU-x) ADX-H-BCU-P POWER CH3 SOFT FAIL CH2 CH1 SUM BAND COM DL IN 3 DPX 3 UL OUT 3 DL IN 2 DPX 2 UL OUT 2 DL IN 1 DPX 1 UL OUT 1 DL OUT UL IN Figure 3-21 ADX-H-BCU Front & Rear View Functions & Features Combines and balances up to 3 carriers’ signals Easily supports multiple carriers’ signals by adding a single piece of equipment Reduces complexity and expansion costs to support multiple carriers’ signals in a single system Input range: +5 ~ +25dBm Specifications Size: 19.0 x 12.9 x 1.7 inches Weight: 9.9 lbs 3.1.6.1 LEDs The ADX-H-BCU has the following LEDs on the front panel as shown in Figure 3-22. POWER SOFT FAIL Figure 3-22 BCU LED Table 3-5 Advanced RF Technologies, Inc. BCU LED Specifications 37 ADX DAS-Module Power Specifications Solid Green OFF Solid Yellow Solid Green Soft Fail Module power is ON Module power is OFF Soft Fail alarm exist in the RFU No Soft Fail alarms are present in the RFU 3.1.6.2 RF Ports 3.1.6.2.1 DL IN/UL OUT & DPX ports DL IN/UL OUT & DPX Ports are located at the back of BCU and connect directly to a BTS. 3.1.6.2.2 DL OUT/UL IN DL OUT/UL IN Ports are located on the back of ADX-H-BCU and connect directly to the ADX-H-RFU. 3.1.6.3 Communication Port ADX-H-NMS monitors and controls the ADX-H-BCU via this port. DC Power is provided from ADX-H-PSU to the ADX-H-BCU via this port. BAND COM Figure 3-23 Communication Port (BCU) 3.2 HRU The High power remote unit is composed of a (1) Main HRU and up to (1) Extended HRU. Main HRU and Extended HRU use same enclosure. PCS_A_ SERVER AWS_A_ SERVER 700LTE_A_ SERVER DL_A GUI_A UL_A DL_B GUI_B UL_B RS-485_A POWER vG OPTIC_A OPTIC_B AC IN 110V hGdGhjs iGdGhju jGdGmUn RS-485_B Figure 3-24 ADX-HRU Single enclosure (bottom view) 3.2.1 Port 3.2.1.1 RF Port 3.2.1.1.1 Antenna server port (DIN type) Advanced RF Technologies, Inc. 38 - Non-use port is masked with blank cover. 3.2.1.1.2 Extension port (N type) DL_A, UL_A : extension of additional band DL_B, UL_B : reserved port 3.2.1.2 Optic port Figure 3-25 Inner Optic port connection Figure 3-26 Optic connection 3.2.1.3 GUI, RS 485 port Advanced RF Technologies, Inc. 39 - GUI_A, RS 485_A is for additional band GUI_B, RS 485_B is for reserve GUI connectivity is along with optic line position (See the pictures below of various combinations) PCS_A_ SERVER AWS_A_ SERVER 700LTE_A_ SERVER DL_A GUI_A UL_A DL_B GUI_B UL_B RS-485_A POWER vG OPTIC_A OPTIC_B AC IN 110V hGdGhjs iGdGhju jGdGmUn RS-485_B |Gn|pG |Gn|pG Figure 3-27 ADX-HRU 3bands GUI connection (Single enclosure) PCS_A_ SERVER AWS_A_ SERVER 700LTE_A_ SERVER DL_A GUI_A UL_A DL_B GUI_B CELL_A_ SERVER UL_B DL_A GUI_A RS-485_A POWER vG OPTIC_A UL_B RS-485_A OPTIC_A OPTIC_B AC IN 110V hGdGhjs iGdGhju jGdGmUn hGdGhjs iGdGhju jGdGmUn RS-485_B |Gn|pG |Gn|pG Figure 3-28 ADX-HRU 4bands GUI, RS 485 connection (2 enclosures) LEDs HRU has the following LEDs on the front panel as shown in Figure 3-29. GUI_A GUI_B RS-485_A POWER OPTIC_A DL_B POWER OPTIC_B AC IN 110V 3.2.2 UL_A GUI_B OPTIC_B IN 110V hGdGhjs iGdGhju jGdGmUn RS-485_B Advanced RF Technologies, Inc. 40 RS-485_B Figure 3-29 HRU LED Table 3-6 Master HRU LED Specifications ADX DAS-Module Power 3.2.3 Solid Green OFF Specifications Module power is ON Module power is OFF AC On/Off Switch, AC Port Figure 3-30 HRU AC Port Figure 3-31 HRU AC Switch The AC Power on/off switch is located on PSU in the enclosure of each ADX-HRU. The ADX-HRU is operated at the only 110V AC. The socket-outlet shall be installed near the equipment and shall be easily accessible (WARNING: The AC switch must be set to OFF before cable connection to avoid equipment damage and personal injury.) (WARNING: To avoid damage, be sure 110V AC for operation of ADX-HRU.) (CAUTION: DOUBLE POLE/NEUTRAL FUSING.) The procedure for connecting HRU Advanced RF Technologies, Inc. 41 4. AC S/W OFF AC cable connection Optic connection RF cable connection RS 485 connection AC S/W ON CABLE CONNECTION 4.1 Head End Connection Diagrams 4.1.1 Front/Rear Head End Connection View with Optional BCU unit ADX-H-BCU-P POWER ADX-H-OPT POWER LD FAIL1-4 LINK1 UL1 SOFT FAIL LINK2 LINK3 UL2 UL3 UL4 DL2 DL3 DL4 LINK4 LD FAIL5-8 LINK5 LINK6 LINK7 LINK8 UL5 UL6 UL7 UL8 DL5 DL6 DL7 DL8 ADX-H-CHC DL1 ADX-H-RFU-P ADX-H-RFU-7 POWER POWER DL OUT UL IN ADX-H-RFU-A POWER DL OUT UL IN POWER DL OUT UL IN DL OUT SOFT FAIL SOFT FAIL SOFT FAIL SOFT FAIL HARD FAIL HARD FAIL HARD FAIL HARD FAIL DL SIG LOW DL SIG LOW DL SIG LOW DL SIG LOW IL FA ST IL FA ER ER FT HOST FA SO SO PO FT FA IL -H ADX-H-NMS LO PO TT ADX-H-PSU IL -R FA IL -H FA IL LIN -R FA IL -H LIN FA IL -R UL IN ADX-H-RFU-C HE VIEW REMOTE RU VIEW CH3 CH2 CH1 SUM BAND COM DL IN 3 DPX 3 UL OUT 3 VHF UL 2 UL OUT 2 DL IN 2 VHF DL 2 DPX 2 UL OUT 2 DL IN 1 DPX 1 DL IN 2 UL OUT 1 VHF UL 1 DL OUT UL OUT 1 VHF DL 1 UL IN DL IN 1 OPT LINK 8 LINK 7 LINK 6 UL8 UL7 UL6 DL8 DL7 DL6 LINK 5 LINK 4 UL5 UL4 DL5 DL IN DL4 UL OUT DL IN UL OUT LINK 3 UL3 UL2 DL3 DL2 DL IN LINK 2 LINK 1 UL1 DL1 UL OUT DL IN UL OUT DPX DPX DPX DPX ADX-H-RFU-A ADX-H-RFU-C ADX-H-RFU-7 ADX-H-RFU-P OFF OPT 2 OPT 3 OPT 4 BAND COM 1 BAND COM 2 AUX_CH 1 BAND COM 3 BAND COM 4 AUX_CH 2 BATTERY S/W ON OFF OPT 1 Advanced RF Technologies, Inc. BATTERY 24V 1A 42 BATTERY INSTALL AC SELECT AC IN OFF/ON yz[_\ wGMGz ym Figure 4-1 4.1.2 HE Cable connection (1 ADX-RACK-ODU +1 BCU) Rear Head End Connection View with (4) ADX-RACK-ODU units VHF UL 2 UL OUT 2 VHF DL 2 DL IN 2 VHF UL 1 UL OUT 1 VHF DL 1 DL IN 1 OPT LINK 8 LINK 7 VHF UL 2 UL OUT 2 LINK 6 VHF DL 2 LINK 5 LINK 4 DL IN 2 VHF UL 1 LINK 3 LINK 2 UL OUT 1 VHF DL 1 LINK 1 DL IN 1 OPT LINK 8 LINK 7 VHF UL 2 UL OUT 2 LINK 6 VHF DL 2 LINK 5 LINK 4 DL IN 2 VHF UL 1 LINK 3 LINK 2 UL OUT 1 VHF DL 1 LINK 1 DL IN 1 OPT LINK 8 LINK 7 VHF UL 2 UL OUT 2 LINK 6 VHF DL 2 LINK 5 LINK 4 DL IN 2 VHF UL 1 LINK 3 LINK 2 UL OUT 1 VHF DL 1 LINK 1 DL IN 1 OPT LINK 8 LINK 7 LINK 6 UL8 UL7 UL6 DL8 DL7 DL6 LINK 5 LINK 4 UL5 UL4 DL5 DL IN DL4 UL OUT DL IN UL OUT LINK 3 LINK 2 UL3 UL2 DL3 DL2 DL IN LINK 1 UL1 DL1 UL OUT DL IN UL OUT DPX DPX DPX DPX ADX-H-RFU-A ADX-H-RFU-C ADX-H-RFU-7 ADX-H-RFU-P OFF OPT 2 OPT 3 OPT 4 BAND COM 1 BAND COM 2 AUX_CH 1 BAND COM 3 BAND COM 4 AUX_CH 2 BATTERY S/W ON OFF OPT 1 BATTERY 24V 1A BATTERY INSTALL AC SELECT AC IN OFF/ON yz[_\ wGMGz ym Figure 4-2 Advanced RF Technologies, Inc. HE Cable connection (4 ADX-RACK-ODUs) 43 4.2 High Power Remote Unit Connection Diagrams Ethernet cable for RS 485 is crossover type PCS_A_ SERVER AWS_A_ SERVER 700LTE_A_ SERVER DL_A GUI_A UL_A DL_B GUI_B UL_B RS-485_A POWER vG OPTIC_A OPTIC_B AC IN 110V hGdGhjs iGdGhju jGdGmUn RS-485_B Figure 4-3 PCS_A_ SERVER AWS_A_ SERVER 700LTE_A_ SERVER ADX-HRU 3bands connection (Single enclosure) DL_A GUI_A UL_A DL_B GUI_B CELL_A_ SERVER UL_B DL_A GUI_A RS-485_A POWER vG OPTIC_A UL_A DL_B GUI_B UL_B RS-485_A POWER OPTIC_B OPTIC_A OPTIC_B AC IN 110V AC IN 110V hGdGhjs iGdGhju jGdGmUn hGdGhjs iGdGhju jGdGmUn RS-485_B RS-485_B Figure 4-4 ADX-HRU 4bands connection (2 enclosures) x WARNING! The RS-485 ports should NEVER be connected to the Enthernet port of laptop or Ethernet Network Equipment. Doing so may cause serious damage to the Remote Modules or network equipments. Advanced RF Technologies, Inc. 44 5. MOUNTING METHOD 5.1 Head End 5.1.1 Rack Mount Figure 5-1 HE Rack Mount (Front & Rear view) Expandable up to 4 ADX-RACK-ODUs, 4 BCUs and 2 AUX CHs Advanced RF Technologies, Inc. 45 5.1.2 Wall Mount Figure 5-2 HE Wall Mount (Top View) Expandable up to 3 units (ODU, BCU) or max 3U (132mm) ODU or BCU will be stacked up above basic 19” HE chassis which includes NMS, RFU, PSU and CHC Advanced RF Technologies, Inc. 46 5.2 HRU 5.2.1 Wall Mount ADX-HRU is support only wall mount. Figure 5-3 6. HRU Wall Mount INSTALLATION 6.1 Pre-Installation Inspection Please follow these procedures before installing ADX HRU equipment: Verify the number of packages received against the packing list. Check all packages for external damage; report any external damage to the shipping carrier. If there is damage, a shipping agent should be present before you unpack and inspect the contents because damage caused during transit is the responsibility of the shipping agent. Open and check each package against the packing list. If any items are missing, contact ADRF customer service. If damage is discovered at the time of installation, contact the shipping agent. Verify the AC voltage with DVM (Volt meter) is 110V AC. Incorrect AC voltage can damage the ADX equipment. This power of this system shall be supplied through wiring installed in a normal building. If powered directly from the mains distribution system, it shall be used additional protection, such as overvoltage protection device. Over voltage category(OVC) & Pollution degree(PD) Over voltage category (OVC) Advanced RF Technologies, Inc. OVC II 47 Pollution degree (PD) PD2 6.2 ADX DAS Installation Procedure 6.2.1 HE Installation Procedure CAUTION: ADX DAS HE should be installed inside building only. 6.2.1.1 Installing a ADX DAS HE in a rack The ADX HE chassis mounts in a standard 19” (483mm) equipment rack. Allow clearance of 3” (76mm) at the front and rear, and 2” (51mm) on both sides for air circulation. No top or bottom clearance is required. Consideration: Eight mounting holes are located on 4 corners of ADX HE to attach it to the 19” rack. The ADX HE must be securely attached to a rack that can support the weight of the ADX. Mount procedure The following steps should be followed while mounting the ADX HE Detach the wall mount bracket assembled located at the base of the ADX-HE chassis Verify that the HE and Mounting holes are in good condition Set the ADX DAS HE against the 19”rack and secure the unit with screws Verify that ADX HE is securely attached Connect the GND cable Connect the RF cable Connect the Power Connect the Optic cable Advanced RF Technologies, Inc. 48 Figure 6-1 Advanced RF Technologies, Inc. ADX HE 19” Rack Mount Instructions 49 6.2.1.2 Wall mounting the ADX DAS HE If the ADX HE chassis is being mounted to a wall, then allow clearance of at least 17” (430mm) on the top (front side of HE) and 2” (51mm) on the bottom (rear side of HE) and 2” (51mm) on both sides and front for air circulation. Mount procedure The following steps should be followed when wall mounting the ADX HE Verify that the HE and Mounting hole are in good condition Place the ADX HE against the wall and mark of the mounting holes Drill holes(4holes, 18Żmm, 50mm depth) in the installation surface and insert the anchor bolts Bolt the ADX HE to the wall Make sure the ADX HE is securely attached Connect the GND cable Connect the RF cable Connect the Power Connect the Optic cable Figure 6-2 Advanced RF Technologies, Inc. ADX HE Wall Mount Instructions 50 6.2.1.2.1 Installing added rack type modules into basic HE chassis Additional modules such as the ADX-RACK-ODU and ADX-H-BCU can be mounted to the Chassis (ADX-H-CHA) using the included mounting brackets that come with the add-on modules. A maximum of up to 3 addon modules (ODU, BCU) can be mounted to the chassis ODU or BCU will be stacked up above basic 19” HE chassis which includes NMS, RFU, PSU and CHC Figure 6-3 Advanced RF Technologies, Inc. Wall Mount Instructions for ADX-HE added 1U Unit 51 6.2.2 RU Installation Procedure Wall mounting the ADX HRU Mount procedure The following steps should be followed while mounting the Remote Module Verify that the HRU and Mounting hole are in good condition Separate the wall mount bracket from the HRU Placed the wall mount bracket against the wall and mark off the mounting holes Drill holes(4holes, 18Żmm) in the installation surface then insert the enclosed anchor bolts Bolt the mounting bracket to the wall Install the HRU to the mounting bracket Fasten the HRU to the mounting bracket using the included screws Verify that the HRU is securely attached Connect the Antenna cable Connect the Power Connect the Optic cable (if applicable) Advanced RF Technologies, Inc. 52 Figure 6-4 Advanced RF Technologies, Inc. HRU Wall Mount Instructions 53 6.3 Grounding A ground cable is included in the box. The grounding terminals are located at the rear of the ADX HE and RU. The grounding cable should be properly connected before powering on the equipment. BATTERY 24V OPT 2 OPT 3 OPT 4 BAND COM 1 BAND COM 2 AUX_CH 1 BAND COM 3 BAND COM 4 AUX_CH 2 BATT S/W OFF OPT 1 Figure 6-5 Figure 6-6 BATTERY INSTALL AC SELECT ON/OFF AC IN Ground Cable Connection (HE rear side) Ground Cable Connection (HRU dual side) Round terminals located on the side of a 1.25mmŒ(16AWG)or more wires Using permanently connected to earth. Advanced RF Technologies, Inc. 54 6.4 Optic Port Cleaning We recommend cleaning optic connector using a dry optical cleaning swab or tissue in a dry environment as needed. We recommend cleaning the optic connectors only if the expected optic loss is higher than the loss reported in the Web-GUI by 1.5dBo. (Figure 6-7) When optic connector are not in use, the port should be covered with a protective dust cap. (Figure 6-8) Figure 6-7 Optic Connector Cleaning (left) and Optic Port Cleaning (right) Figure 6-8 Advanced RF Technologies, Inc. SC/APC Optic Connector Dust Cap 55 7. COMMISSIONING The commissioning process is composed of the following: Pre-Commissioning Check (refer to section 7.1) Optic Commissioning (Optic loss compensation) (refer to section 7.2.1) HE commissioning (refer to section 7.2.2) RU commissioning (refer to section 0) Commissioning verification (refer to section 0) 7.1 Pre-Commissioning Check 7.1.1 Verify cable connections Before powering up units, check all RF cables, fiber cables, and power cables connections. All power LEDs should be lit 1 minute after the components have been turned on. Check whether LD & PD LEDs of HE ODU modules are solid GREEN. (PD LED will be lit green when connected to a Master RU). 7.1.2 If the PD LED for the link with a connection with to a HRU is OFF, then check the optic cable connection. If the optic cable is good and the PD LED is not lit green, the try another optic port on the ADXRACK-ODU to see if the other port lights up green. Connect to the Web-GUI Confirm that the NMS Host/Remote switch is set to the Host position Confirm that the HE View/RU View switch is set to the HE View position Connect the RJ-45 crossover cable from the Ethernet port of NMS to the Ethernet port of laptop Launch a standard Internet browser like IE or Google Chrome and type the System Controller’s IP address (192.168.63.1) into the addess bar On the login screen use the following default login/password to gain access: Username: adrf Password: adrf Figure 7-1 Advanced RF Technologies, Inc. Login window 56 7.1.3 Check Navigation Tree Status Check whether the status of navigation tree is Lock or Unlock. The navigation tree should be in the “Unlock” state in when adding or removing active ADX components. Figure 7-2 Navigation tree Lock/Unlock When the system is locked: Unable to detect any hardware that is added Able to detect any link fails (communication errors between NMS and components) System should be locked after final commissioning When the system is unlocked: Unable to perform BCU, RFU, or HRU commissioning System is continually scanning for new hardware 7.1.4 Set Location Info, Installer Info and Date & Time Go to the Install page of NMS Enter Location & installer information Set current Date & Time 7.1.5 Verify Navigation Tree Links Check whether all units connected to HE & HRU are being displayed in the navigation tree. Navigation tree is located on the left side of Web-GUI (Figure 7-3 ) Figure 7-3 Navigation tree Check whether link fails exist. Link fails status can be seen on the front panel of NMS module via the Link FailH and Link Fail-R LED lights. If LINK-H fail exists, power cycle the HE PSU and check if LINK-H fail is still present and repeat this step up to 3 times or until the alarm clears. If LINK-H fail still exists after 3 power cycles, then contact ADRF Technical support. If LINK-R fail exists, power cycle the ADX-H-ODU module which is connected to the Master HRU with link fail and check to see if the LINK-R fail is still present and repeat this step up to 3 times or until the alarm clears. If LINK-R fail still exists after 3 power cycles, contact ADRF Technical support. Advanced RF Technologies, Inc. 57 7.1.6 BOM Comparison & Check Band Configuration BOM comparison Check Band Configuration 7.1.7 On the System information page in the System menu, the list of all components connected to the ADX-H-NMS should match the ADX Navigation tree. This list can be used to verify BOM generated by designer or installer for all active components. Please note that passive components such as the ADX-H-CHC, ADX-R-CHC, ADX-H-PSU, and the ADX-R-4WS will not show up on this report. Check whether the band configuration of ADX-H-RFU is identical to the band configuration of the ADX HRU units. Any discrepancies will appear in the System Information report. Check to see if there are multiple remote modules with the same frequency bands within 1 remote unit. This information is displayed on the System Information page in the System menu as notification message. Lock current navigation tree If there are no errors in the process of BOM Comparison & Check Band Configuration, then lock the Navigation Tree by cliking on the “Lock System” button. After locking the Navigation Tree, link fail alarms should not appear. If link fail alarms are present, please check the physical connection of the device with the link fail alarm. The system must first be placed in the “Unlock” state before adding any new devices. Newly added devices will appear in the Navigation Tree when the page is refreshed. Once all new hardware has been added to the Navigation Tree, the tree must be locked before commissioning the system. Advanced RF Technologies, Inc. 58 7.2 Commissioning 7.2.1 Optic Commissioning Figure 7-4 ODU Install page Navigate to the Install page of ADX-H-ODU (Figure 7-4) Compare the values of measured optic loss (LD power – PD power) in the Web-GUI with the actual optic loss which is typically measured at the time of installation of the fiber. The calculated optic loss is displayed when the mouse pointer is placed over the Status indicator of each link Figure 7-5 If the difference between the measure optic loss and the calculated loss is larger than 1.5dBo, then clean the optic connector and optic port using optical cleaning swab. (refer to section 6.4) The following is the definiton of the Status indicator of each link: measured optic loss display Green: Indicates that optic loss is less than 5dBo Orange: Indicates that optic loss is greater than 5dBo Gray: No Master HRU is connected to this link. The following is the definition for the background color of the Commissioning button: Green: Indicates that no optic loss compensation is needed. Orange: Indicates that optic loss compensation is needed. Gray: No Master HRU is connected to this link. 7.2.1.1 How to compensate the optic loss Advanced RF Technologies, Inc. 59 Optic loss compensation should be performed when the color of “Commissioning” button is orange. The “Commissioning” button will turn orange when the difference between the compensated attenuation and the actual compensated attenuation level is greater than 1.5 dB. Optic compensation can be performed by clicking the orange “Commissioning” button. The optic loss compensation for uplink and downlink are performed separately. The optic loss compensation for downlink will be performed based on the LD level of the ODU and the PD level of the Master RU. The optic loss compensation for uplink will be performed based on the LD level of the Master HRU and the PD level of the ODU. Optic loss compensation adjusts the attenuation based on Table 7-1 and the calculated optic loss (LD level-PD Level). The calculated optic loss is displayed when a mouse is placed on the circle of each link. (Refer to section 7.2.1.1) Based on the table below, when the calculated optic loss is 1dB, the attenuation will be set to 11dB. The attenuator for downlink optic loss compensation is located at the Master RU. The attenuators for uplink optic loss compensation are located at the ODU. Table 7-1 Optic loss compensation table Optic Loss (dBo) Compensated Attenuation (dB) 0.5 13 12 11 Example: Let’s say that this ADX-H-ODU had previously been commissioned in a system where the optic loss was 3 dBo. In the previous system, the correct amount of attenuation is 7dB. The ADX-H-ODU was moved to another site and the new system has an optic loss of only 1dBo. At 1dBo of loss, the correct amount of attenuation should be 11 dB. When this system powers on, optic commissioning will need to be performed because the difference between the old attenuation level and the new attenuation level is 4dB which exceeds the 1.5 dB threshold. Once optic commissioning is performed, it will set the attenaution level to 11 dB. Advanced RF Technologies, Inc. 60 7.2.2 HE Commissioning HE commissioning is composed of HE BCU and HE RFU commissioning. The HE BCU is an optional component and should be used when WPSs’ signals are being used in the same frequency band. 7.2.2.1 Composite power To perform HE commissioning, the user should calculate downlink composite input level and add the proper amount of breath room required for rise in traffic. Information that is needed to calculate commissioning levels are: 7.2.2.1.1 7.2.2.1.1.1 DL Composite Input Level Calculations for HE Commissioning Single WSP in a frequency band Measure the output power of the BTS signal that will be inserted into the RFU using a Spectrum Analyzer. Service frequency band Service technology The number of wireless service provider The number of carriers per technology The number of band sharing same amplifier If input signal includes more than one technology, then measure the composite power of each technology. Based on Table 7-2, calculate the maximum composite input level by using the following formula: “Output power of BTS of technology being used” + “back-off value” (refer to Table 7-2) If calculated composite HE DL input power exceeds the permitted maximum input range, then additional attenuation will need to be added so that the calculated HE DL input power does not exceed 25dBm. Table 7-2 7.2.2.1.1.2 Back-off value for each technology due to traffic breathing Technology Connected to BTS CDMA 1xEVDO WCDMA HSPA iDEN GSM LTE 6~8dB 6~8dB 8~10dB 8~10dB 0~3dB 0~3dB 8~10dB Multiple WSPs in a frequency band When multiple WSPs exist in a frequency band at the same time, the ADX-H-BCU can be used to combine/divide the signals received from multiple WSPs. Measure the output power of the BTS signal that will be inserted into the BCU using a Spectrum Analyzer. The ADX-H-BCU can receive up to 3 incoming DL signals. Each incoming signal can be attenuated individually allowing the user to specify power ratios to control the power per carrier. The downlink path of BCU has the input range from 0 to 25dBm. If the downlink output of BCU exceeds DL output ALC level set by user, ALC function will activate and limit the DL output from exceeding the defined ALC level. The DL output of ADX-H-BCU is transferred to the DL input of RFU. If input signal includes more than one technology, then measure the composite power of each technology. Based on Table 7-2, calculate the maximum composite input level by using the following formula: “Output power of BTS of technology being used” + “back-off value” (refer to Table 7-2) Advanced RF Technologies, Inc. 61 - If calculated composite HE DL input power exceeds the permitted maximum input range, then additional attenuation will need to be added to the BCU input port so that the calculated HE DL input power does not exceed 25dBm. The RFU DL input commission level is the combined DL Output ALC Level of the ADX-H-BCU which can be obtained from the Control page of the ADX-H-BCU. 7.2.2.1.2 7.2.2.1.2.1 The maximum input level of HE RFU will not exceed 10dBm (= 5dBm + 10*log10 (3)) because the maximum output of BCU each path is limited to 5dBm by the ALC function. Example of commissioning value calculation AT&T signal in the PCS band with multiple technologies (without attenuation) Table 7-3 shows 2 technologies being used by AT&T within the same band which are inputted into the HE RFU. Table 7-3 Input signal conditions @HE RFU downlink input WSP AT&T Technology GSM WCDMA Total input per band 20.0dBm 20.0dBm HE Total Input 23.0dBm The downlink input level for each technology should be measured because two technologies (GSM & WCDMA) are being used by AT&T in the PCS band. The HE DL maximum input level for each technology can be calculated by adding the back-off value per technology due to traffic load change (breathing). Total measured input power for GSM is 20dBm and for WCDM is 20dBm. Estimated Total Max Input per band = Total input per band + back-off value per band for breathing. HE DL maximum input level becomes the sum of HE DL maximum input level for each technology. The sum of HE DL maximum input level for each technology is 28dBm (25.0dBm for GSM + 25.0dBm for WCDMA = 28.0dBm) and this value is 3dB (28dBm – 25dBm) larger than the maximum DL input of HE RFU. If the calculated HE downlink commissioning value exceeds the maximum DL input of HE RFU, attenuation will need to be added have the calculated HE downlink commissioning level not exceed 25dBm. Table 7-4 HE maximum downlink input level without 10dB attenuator WSP AT&T Total input per band 20.0dBm Back off per band for breathing 5.0dB 20.0dBm 5.0dB Estimated Total Max Input per band 25.0dBm 25.0dBm Estimated Total Max Input 28.0dBm Available Max Input 25.0dBm 7.2.2.1.2.2 AT&T signals in the PCS band with multiple technologies (with 10dB of attenuation) After adding 10dB of attenuation to the system, the input levels per band and HE Total Input can be seen below: Table 7-5 HE downlink input signal conditions after adding 10dB attenuator to HE downlink input port WSP Technology Advanced RF Technologies, Inc. AT&T GSM WCDMA 62 Total input per band 10.0dBm 10.0dBm HE Total Input 13.0dBm The RFU can now be commissioned with the 10dB of attenuation by using a DL input commission level of 18dBm. Table 7-6 HE maximum downlink input level after adding 10dB attenuator to HE downlink input port WSP AT&T Total input per band 10.0dBm Back off per band for breathing 5.0dB 10.0dBm 5.0dB Estimated Total Max Input per band 15.0dBm 15.0dBm Estimated Total Max Input 18.0dBm Available Max Input 25.0dBm 7.2.2.1.2.3 Multiple WSPs’ signals exist in the PCS band (with power ratio) Table 7-7 displays all the various incoming DL signals that are entering into the HE PCS BCU. The ADX-H-BCU has total 3 input ports and in the example below each port has been assigned to Sprint, AT&T, and VzW. Table 7-7 Input signal conditions @HE BCU downlink input WSP Sprint- CH1 Technology CDMA GSM AT&T- CH2 WCDMA CDMA Total input per band 5.0dBm 10.0dBm 10.0dBm 7.0dBm BCU Total Input 14.5dBm Calculate maximum DL input level for each WSP factoring in the back-off values. Table 7-8 WSP Sprint- CH1 5.0dBm 10.0dBm 10.0dBm 7.0dBm Back off per band for breathing 4.0dB 5.0dB 5.0dB 4.0dB 15.0dBm 15.0dBm AT&T- CH2 9.0dBm 18.0dBm VZW- CH3 11.0dBm Based on the calculated maximum DL input level for each port, the user should decide on a target maximum Input power for each BCU port. Targeted maximum Input power for each BCU port should not be less than the calculated maximum DL input level for each port and should not exceed the maximum input level, 25dBm. Table 7-9 WSP Targeted maximum input power Targeted DL Output Power Ratio set by user HE maximum downlink input level Total input per carrier Estimated Total Max Input per carrier VzW- CH3 Targeted maximum input power Sprint- CH1 AT&T- CH2 VZW- CH3 9.0dBm 18.0dBm 11.0dBm 19.2dBm 30.0% 20.0% 50.0% Calculate the DL maximum output power of BCU based on targeted maximum Input power for each BCU port. The highest power ratio that has been set is VZW- CH3 @ 50%. The ADX-H-BCU will apply attenuation to this port to set the maximum output power to 5dBm, therefore 6dB of attenuation will be applied to this port. Advanced RF Technologies, Inc. 63 ! The attenuation and DL output ALC level for the other ports are set based on the formula below to keep the power ratio between BCU ports. The maximum output power for the specified path = 10*log10[10^(Max_ALC/10)x(Pwr_Ratio)/ Max_Ratio] Max_ALC: DL output ALC level for the path with maximum power ratio = 5dBm Pwr_Ratio: Targeted DL output power ratio value for the specified path Max_Ratio: maximum power ratio value The attenuation for the specified path = The targeted maximum input power for the specified path The maximum output power for the specified path DL output ALC level = The targeted maximum input power for the specified path - The attenuation for the specified path The path for AT&T- CH2 The maximum output power = 10*log10[10^(5/10)x20%/50%] = 1.02dBm The ATT value = 18.0dBm-1.02dBm=16.98dB Î 16.5dB(the control step of used attenuator is 0.5dB) DL output ALC level = 18dBm – 16.5dB = 1.5dBm The path for Sprint- CH1 The maximum output power = 10*log10[10^(5/10)x30%/50%] = 2.78dBm The ATT value = 9.0dBm-2.78dBm=6.22dB Î 6.0dB(the control step of used attenuator is 0.5dB) DL output ALC level = 9.0dBm – 6.0dB = 3.0dBm The DL maximum output power of BCU is the sum of maximum output power for each port and this power becomes the HE RFU input commissioning level. The maximum input level of HE RFU should be less than 10dBm (= 5dBm + 10*log10 (3)) because the maximum output of BCU per each path doesn’t exceed 5dBm by ALC function. Table 7-10 WSP Targeted maximum input power Maximum Output Power per carrier Sprint AT&T VZW 9.0dBm 18.0dBm 11.0dBm 19.2dBm Targeted DL Output Power Ratio set by user 30.0% 20.0% 50.0% DL maximum output power (ATT control step, 0.5dB is not considered) 2.78dBm 1.02dBm 5.0dBm 6.0dB 16.5dB 6.0dB 3.0dBm 1.5dBm 5.0dBm ATT value DL output ALC level or DL Maximum output power (ATT control step, 0.5dB is considered) DL Output Power Ratio considering ATT control step 0.5dB Advanced RF Technologies, Inc. 8.2dBm(RFU DL Input commissioning level) 30.37% 21.50% 64 48.13% 7.2.2.1.3 HE BCU Commissioning When performing BCU commissioning, the user will need to enter the DL input commissioning level and Targeted DL Output Power Ratio for each RF path. Refer to section 7.2.2.1 to calculate DL input commissioning level. If a port is not being used, the DL Input Commissioning Level should be set to “disabled”. 7.2.2.1.3.1 HE BCU Commissioning Procedure Go to Install page of the BCU on the Web-GUI Figure 7-6 BCU Install Window Select a DL Input Commissioning Level for each RF path Enter HE BCU downlink output power ratio for each port Press the “Apply” button The attenuation value and output ALC level for each DL/UL path will be set automatically based on the HE BCU downlink input commissioning level and downlink output power ratio for each port. The BCU will check to see if ALC is active on any of the ports. DL Input Commissioning Levels range is 0~+25dBm (0.5dB step) During the commissioning routine, if ALC is activated, a popup message will appear stating that ALC is running. If this is the case, then there is a chance that the “back-off” value needs to be increase to allow more breathing room. The BCU checks to see if the BCU has any alarms. If a soft fail is present, the system will prompt the user whether or not they would like to continue. If hard fail is present, the commissioning process will stop immediately. Advanced RF Technologies, Inc. 65 7.2.2.1.4 HE RFU commissioning If a BCU is being used in the system, the BCU should be commissioned before commissioning the HE RFU. For RFU commissioning, the user will need to calculate the DL input commissioning level. Refer to section 7.2.2.1 to for information to determine the DL input commissioning level. 7.2.2.1.4.1 HE RFU commissioning Procedure Go to Install page of RFU on the Web-GUI Enter HE RFU downlink input commissioning level Press the “Apply” button The attenuation levels will be set automatically based on DL Input Commissioning Level that is selected. Checks to see if DL input is low. Figure 7-7 During the commissioning routine, if DL input level is 10dB less than commissioning level, a popup message will appear stating that DL input is low. If this is the case, then there is a chance that the “back-off” value needs to decrease breathing room. During the commissioning routine, if ALC is activated, a popup message will appear stating that ALC is running. If this is the case, then there is a chance that the “back-off” value needs to be increase to allow more breathing room. Checks to see if the RFU has any alarms. Input range: 0~+25dBm, 0.5dB step Checks to see if ALC is active. RFU Install Window If a soft fail is present, the system will prompt the user whether or not they would like to continue. If hard fail is present, the commissioning process will stop immediately. Commissioning is successfully completed. Advanced RF Technologies, Inc. 66 7.2.3 HRU Commissioning HRU composite downlink output level can be determined using simulation tools like iBwave. User should simulate this output level in order to ensure that all service areas have sufficient coverage. The simulated composite DL output power value should not exceed the maximum output level of the HRU, which is 43dBm. The simulated composite DL output power value would be used as HRU DL commissioning output level. DL attenuation value will be adjusted automatically based on this simulated value HRU commissioning level. For HRU commissioning, user should enter information on DL output commissioning level. Refer to section 7.2.2.1 to calculate DL output commissioning level. Go to Install page of Remote Module on the webGUI Figure 7-8 Remote Module Install Window Enter HRU downlink output commissioning level Press the “Apply” button The attenuation level for each DL/UL path will be set automatically based on DL Output Commissioning Level that is entered Checks to see if DL output is low. During the commissioning routine, if ALC is activated, a popup message will appear stating that ALC is running. If this is the case, then there is a chance that the “back-off” value needs to be increase to allow more breathing room. Checks to see if the Sub-RU has any alarms. During the commissioning routine, if DL output level is 10dB less than commissioning level, a popup message will appear stating that DL output is low. If this is the case, then there is a chance that the “back-off” value needs to decrease breathing room. Checks to see if ALC is is active. Output range: 5~+43dBm, 0.5dB step If a soft fail is present, the system will prompt the user whether or not they would like to continue. If hard fail is present, the commissioning process will stop immediately. Commissioning is successfully completed. Advanced RF Technologies, Inc. 67 7.3 DAS Install Verification 7.3.1 Setting SNMP & Remote IP Go to Install page of NMS (refer to section 8.2.4.1.4) When external modem box is connected, user should set SNMP & Remote IP information. 7.3.2 Verification through Web based GUI Go to System information page of System (refer to section 8.2.5.4.1) 7.3.3 Check if Remote Module with same frequency band exist more than one within one HRU. Check if there are any noncommissioned modules in HE or RU. Check if any critical alarms are present. UL noise power detection When the UL noise levels is larger than the expected value, ADX DAS has a function that will measure the uplink noise for each HRU and will generates a report with the UL noise levels. This will help the user determine which HRU might be the cause of the elevated UL noise. UL noise power measurement can be performed for only one frequency band at a time. For more information, refer to section 8.2.3.3.3. Advanced RF Technologies, Inc. 68 8. WEB-GUI 8.1 Web-GUI Setup The Web-GUI allows the user to communicate with the DAS system either locally or remotely. To connect to the DAS system locally, you will need a laptop with an Ethernet port and a RJ-45 crossover cable. To connect to the DAS system remotely, you will need to have an active internet connection and the ADX system must have and external modem box connected to the ADX. 8.1.1 DAS system/PC Connection Using Web-GUI Verify that your Local Area Connection is set to Obtain an IP address automatically under the Internet Protocol (TCP/IP) properties Connect the RJ-45 crossover cable between the laptop’s Ethernet port and the repeater’s Ethernet port Launch an Internet Browser Type the following IP address into the address bar of Microsoft Internet Explorer: http://192.168.63.1 If you are connecting to the unit remotely (use of a modem), then skip this and next step. If you are connecting to the unit remotely, then type the IP address of the modem to connect to the unit The following login screen will appear: Figure 8-1 Login screen If you are not the Administrator, please type in your assigned username & password which you should have received from the Administrator. Table 8-1 Account Information for Login Account type Show items Control Items Default ID Default Password Administrator User Guest all Items restricted items restricted items all items restricted items read-only admin adrf guest admin adrf guest Advanced RF Technologies, Inc. 69 8.2 Administrator/User Mode 8.2.1 Common 8.2.1.1 Navigation tree Lock/Unlock When the system is “Locked”, a green lock icon will appear above the navigation tree. When the system is locked, new devices cannot be added. Any devices added to the system when the system is “Locked” will not be detected by the NMS. After a system has been commissioned properly, the system should be left in the “Locked” position. To unlock the system, click on the “Unlock System” button to the right of the icon. When the system is “Unlocked”, an orange icon will appear above the navigation tree. When the system is unlocked, new devices added to the system will be automatically detected. Once the new hardware appears in the system tree, then the system can be locked. To lock the system, click on the “Lock System” button to the right of the icon. Figure 8-2 Navigation tree Lock/Unlock 8.2.1.2 Navigation Tree Figure 8-3 Navigation tree The navigation tree located on the left hand side of the Web-GUI allows the user to switch between the various modules that are connected to the system. Table 8-2 Parameters Navigation tree Description Expands the entire navigation tree Collapses the entire navigation tree The module has the expandable subordinate modules The branch is currently expanded The module has soft fail alarm The module has hard fail alarm The module has no alarms (normal) The selected module will have orange colored text Advanced RF Technologies, Inc. 70 8.2.1.3 Power Status Display the power source that is currently being used. Table 8-3 Input Power Status Power Supply Status Display Image AC Battery 8.2.1.4 Commissioning Status Display whether or not the module has successfully been commissioned. Table 8-4 Status Commissioning ICON Display Image Commissioned Not-Commissioned 8.2.1.5 Information Figure 8-4 ADX DAS General Information Information: Displays the serial number, latitude/longitude, firmware version of selected module, and Web GUI version of the NMS. Location: Displays the address where the ADX DAS is installed. Description: Displays the description of selected module. The description of each module can be edited from the Install tab. It is recommended to use the location of the module as the description. This description information can be seen when hovering over the device tree in order to easily identify each component. Technical Support: Displays ADRF’s Technical Support contact information. Installer Contact Info: Displays the contact information of the installer. Advanced RF Technologies, Inc. 71 8.2.2 Status Tab 8.2.2.1 Status – NMS Figure 8-5 Status - NMS The NMS Status page provides an overall view of how the system is performing. From the NMS Status page, the user can see what modules are connected to ADX DAS. In addition, the user can see if any alarms are present in the system and also the commissioning status of each module. 8.2.2.1.1 System Summary Figure 8-6 System Summary The Summary section provides the user with the number of components physically connected, the number of soft/hard/link fails present in the system, and also the number of commissioned and non-commissioned componnets. Advanced RF Technologies, Inc. 72 Table 8-5 Description Connected Display the number of modules physically connected to ADX DAS Soft Fail Display the number of soft fail present on each module Hard Fail Display the number of hard fail present on each module Link Fail Display the number of link fail present on each module Display the number of non-commissioned or commission failed module Commissioned Display the number of successfully commissioned module HE View / HRU View, System Scan Time HE View/RU View Parameters Not Commissioned 8.2.2.1.2 System Summary Description Displays whether the NMS is set to HE view or HRU view. Refer to section 3.1.1.4 System Scan Time Displays the time it takes to scan and update the information of all the modules that are on the navigation tree. This time will increase as more components are added to the system. When Navigation Tree is unlocked, the user should wait at least the “System Scan Time” for the system to detect newly added hardware. Figure 8-7 8.2.2.1.3 System scan time, HE view/RU view HE Alarm Status Display the alarm status of each HE component. Figure 8-8 Advanced RF Technologies, Inc. HE alarm status 73 8.2.2.1.4 HE Commissioning Status Display commissioning status of each HE component. Figure 8-9 Table 8-6 HE Commissioning status Description for HE Commissioning status Status Installed Status Commissioning Status 8.2.2.1.5 Display Description Physically Installed Physically Not-Installed Success Failed or not commissioned Text is black Text is gray Green Gray Alarm Displays alarm status of the NMS. If an alarm is present in the system, the color of the system alarm tab will change according to the type of failure. Table 8-7 Alarm System Power Alarm Description for NMS alarm Severity Description Over Temperature Hard Fail / Soft Fail Temperature of NMS is higher than the threshold level for over temperature alarm Temperature of the NMS is lower than the threshold level for under temperature alarm Under Temperature Soft Fail System Halt Hard Fail HE system halt AC Fail Soft Fail AC power is operating outside of its normal range DC Fail Soft Fail DC power is operating outside of its normal range Over Current Hard Fail Total current of HE is higher than the threshold level for over current alarm Battery Low Soft Fail Voltage of battery connected to HE PSU is lower than the defined threshold Advanced RF Technologies, Inc. 74 8.2.2.2 Status – BCU Figure 8-10 Status – BCU 8.2.2.2.1 Band Displays the bandwidth and the frequency ranges for DL and UL of the BCU module. Figure 8-11 Status – BCU Band 8.2.2.2.2 Power & Atten Figure 8-12 Status – BCU Power & Atten DL Commissioning Level: Displays the commissioning level for each individual RF path. If unit has not been commissioned, “Not Commissioned” will be displayed. Advanced RF Technologies, Inc. 75 x 8.2.2.2.3 DL Input: Displays the currently incoming signal strength of each RF path along with the composite DL input power of all 3 RF paths. Atten: Displays the attenuation values that the system is currently using which is defined by the power ratios specified by the user. DL Output: Displays the output value for each RF path along with the composite DL output power of all 3 RF paths. The DL Output level for each RF path will not exceed 5dBm and the composite output power will not exceed 10 dBm. Power Ratio Figure 8-13 Status – BCU Power Ratio 8.2.2.2.4 Targeted DL Output Power: Displays desired power ratios specified by the user. If unit has not been commissioned, “Not Commissioned” will be displayed. Actual DL Output Power: Displays the currently power ratios that the system is using. These values will fluctuate based on the amount of traffic that is in the system. Alarm Displays the current alarm status of each individual RF path. Parameters for both DL Signal Low and DL Input Overload can be specified from the Control tab. Figure 8-14 Status – BCU Alarm Advanced RF Technologies, Inc. 76 8.2.2.3 Status – RFU Figure 8-15 Status – RFU 8.2.2.3.1 Band Displays the bandwidth and the frequency ranges for DL and UL of the RFU module. Figure 8-16 Status – RFU Band 8.2.2.3.2 Power & Gain (Admin/User) Admin Mode- Displays the Downlink Input/output, Downlink/Uplink Attenuation, and Uplink Output. User Mode- Displays the Downlink Input, Downlink/Uplink Attenuation, and Uplink Output. Figure 8-17 Power & Gain Display (Admin) Advanced RF Technologies, Inc. 77 Figure 8-18 Power & Gain Display (User) Input [dBm]: Displays the Downlink RF input level which comes from the ADX-H-BCU or BTS. This value should be between 0 to 25 dBm. ALC Atten [dB]: The amount of attenuation that is being used by the system when ALC is active. Atten [dB]: The amount of attenuation that has been set manually by the user. Output [dBm]: The downlink/uplink output power of the RFU and NOT the output power of the RU. 8.2.2.3.3 Alarm Displays System, RF, and Power Alarms. If an alarm is present in the system, then the color of the tab will change according to the type of failure. Table 8-8 Alarm Severity Link Fail Soft Fail Over Temperature Hard Fail / Soft Fail Under Temperature Soft Fail System Halt Hard Fail DL Signal not detected Soft Fail System RF Alarm RFU Alarm Status DL Signal Low Input Overload Overpower Power Alarm Advanced RF Technologies, Inc. Soft Fail Hard Fail / Soft Fail Hard Fail / Soft Fail Description A component is physically connected, but the NMS is unable to communicate with it. The temperature of NMS is higher than the threshold level for over temperature alarm. The temperature of NMS is lower than the threshold level for under temperature alarm. System will go into a “System Halt” state when a hard fail alarm does not clear after 10 checks. System Halt can only be cleared with a power cycle, reboot, or factory settings. Downlink input signal is lower than the defined threshold by user. Downlink input signal is lower than the defined threshold by user. Downlink input signal is higher than the defined threshold. Uplink output signal is higher than the defined threshold by user. AC Fail Soft Fail AC power is not operating within parameters. DC Fail Soft Fail DC power is not operating within parameters. Over Current Hard Fail Total current of HE is higher than the threshold level for over current alarm. Battery Low Soft Fail Voltage of battery connected to HE PSU is lower than the defined threshold. 78 8.2.2.4 Status – ODU Figure 8-19 Status - ODU 8.2.2.4.1 Summary The Summary section displays the number of remote modules that are physically connected, the number of soft/hard/link fail alarms, and the number of Remote Module that have been commissioned and the number of Remote Module that need to be commissioned. Figure 8-20 Summary (Status – ODU) Advanced RF Technologies, Inc. 79 Table 8-9 8.2.2.4.2 Summary Description Parameters Description Connected Displays the number of Remote Module’s connected to the ADX-RACK-ODU. Soft Fail Displays the total number of soft fail present. Hard Fail Displays the number of hard fail present on each module. Link Fail Displays the number of link fail present on each module. Not Commissioned Displays the number of non-commissioned or commission failed module. Commissioned Display the number of successfully commissioned module RF Status Displays the DL input power and the UL output power for each ODU. An ADX-RACK-ODU is composed of 2 ODUs. Figure 8-21 RF Status (Status – ODU) 8.2.2.4.3 Optic Status Display LD Power and PD Power for each optic path. LD Power is the power that is being sent to the HRU and PD Power is the power that is being received from the RU. Figure 8-22 Optic Status (Status – ODU) 8.2.2.4.4 Optic Atten (Admin Only) The ADX-H-ODU has 3 types of attenuators. Downlink Common Attenuator- Displays the common attenuation level on the DL path. Uplink Common Attenuator- Displays the common attenuation level on the UL path. Uplink Optic Attenuator- Displays the amount of attenuation used at each optical link. Advanced RF Technologies, Inc. 80 Uplink Common attenuator Downlink Common attenuator Uplink Optic attenuator Figure 8-23 Optic Attenuation (Status – ODU) 8.2.2.4.5 Optic Path Status Displays the optic status for each optic path Figure 8-24 Optic Path Status (Status – ODU) Table 8-10 Status LD Status PD Status Normal LD fail Not Connected Normal PD fail Comm Fail or Not Connected Advanced RF Technologies, Inc. Description for optic path status Display Description Green, optic signal being sent to Master HRU is > -5dBm Orange, optic signal being sent to Master HRU is < -5dBm Gray, no connection between ODU and Master RU Green, optic signal being received from Master HRU is > -10dBm Orange, optic signal being received from Master HRU is < -10dBm Gray, no connection between ODU and Master RU 81 8.2.2.5 Status – HRU Hub RU-Hub is not separate module but is integrated into the master RU. The picture of HRU Hub displayed on web based GUI is same as the picture of master RU. Figure 8-25 Status - HRU Hub 8.2.2.5.1 RU Alarm Status The HRU Hub can support up to 8 remote modules. The HRU alarm status displays the alarm status of each remote module. Figure 8-26 RU Alarm Status (Status - HRU Hub) 8.2.2.5.2 RU Commissioning Status Display the Commissioning status of each Remote Module. Figure 8-27 RU Commissioning Status (Status - HRU Hub) Advanced RF Technologies, Inc. 82 Table 8-11 Description for HRU Commissioning status Status Installed Status Commissioning Status 8.2.2.5.3 Display Description Installed Not-Installed Success Fail or not yet Text is black Text is gray Green Gray Alarm Table 8-12 Alarm Status (Status - HRU Hub) Alarm System Power Alarm Severity Description Link Fail Soft Fail Present when a module cannot communicate with the NMS System Halt Hard Fail System will go into a “System Halt” state when a hard fail alarm does not clear after 10 checks. System Halt can only be cleared with a power cycle, reboot, or factory settings. AC Fail Soft Fail AC power is not within parameters. DC Fail Soft Fail DC power is not within parameters. Over Current Hard Fail Total current of HRU is higher than the threshold level for over current alarm Battery Low Soft Fail Voltage of battery connected to HRU PSU is lower than the defined threshold 8.2.2.6 Status – Remote module Figure 8-28 Status – Remote Module Advanced RF Technologies, Inc. 83 8.2.2.6.1 Band Display the spectrum that is being used. The band column displays the bandwidth that has been used. The downlink column displays the center frequency of the used downlink band. The uplink column displays the center frequency of the used uplink band. Figure 8-29 PCS Band Information (Status – Remote Module) 8.2.2.6.2 Power & Gain (Admin/User) Display the Downlink output, Downlink/Uplink Attenuation, and Uplink Input/output. Figure 8-30 Power & Gain (Admin) Figure 8-31 Power & Gain (User) Admin Input [dBm]: Displays the RF input level for Uplink only for the Remote Module. ALC Atten [dB]: The amount of attenuation used when ALC is activate. Atten [dB]: The amount of attenuation manually set by the user. [M]Output [dBm]: Output power of RF transceiver (1 stage amplification). st nd [H]Output [dBm]: Output power of downlink HPA (2 stage amplification). Input [dBm]: Displays the RF input level for Uplink only for the Remote Module. Atten [dB]: The amount of attenuation manually set by the user. Output [dBm]: Displays the total composite output power. User Advanced RF Technologies, Inc. 84 8.2.2.6.3 Optic Power (Master-RU Only) Display the LD Power and PD Power of optic module inside the Master RU. Figure 8-32 Optic Power (Status – Master HRU only) 8.2.2.6.4 Operating Status Table 8-13 Operating Status (Status – Remote Module) Alarm System Link Fail Over Temperature RF Alarm Power Alarm Advanced RF Technologies, Inc. Severity Description Soft Fail Hard Fail / Soft Fail No communication with NMS. Temperature is higher than the threshold level for over temperature alarm. Temperature is lower than the threshold level for under temperature alarm. System halt on either the Master HRU or Slave RU. System halt occurs when a hard fail alarm fails to clear after 10 checks. LD Fail present in the Master RU’s optic unit. PD Fail present in the Master RU’s optic unit. Uplink input signal is higher than the defined threshold. Downlink output signal is higher than the defined threshold by user. Under Temperature Soft Fail System Halt Hard Fail ORU LD Fail ORU PD Fail Soft Fail Soft Fail Input Overload Hard Fail Over Power Hard Fail / Soft Fail VSWR Soft Fail Triggered when power is being reflected back to the system, typically due to a loose connector. AC Fail Soft Fail AC power is not operating within parameters. DC Fail Soft Fail DC power is not operating within parameters. Over Current Hard Fail Total current of HRU is higher than the threshold level for over current alarm. Battery Low Soft Fail Voltage of battery connected to HE PSU is lower than the defined threshold. 85 8.2.3 Control Tab 8.2.3.1 Control – NMS Figure 8-33 Control - NMS 8.2.3.1.1 Heartbeat Time Allows the user to enable or disable SNMP traps from being sent out and also specify the Heartbeat interval. Time and date stamps of the last 2 heartbeats will be displayed in the “Last heartbeat sent out” section. Figure 8-34 Heartbeat (Control – NMS) 8.2.3.1.2 HE System Allows the user to perform a HE system reboot or HE full system factory settings Figure 8-35 HE System Reboot & Factory Setting (Control – NMS) 8.2.3.1.3 NMS System Allows the user to perform a NMS Unit reboot or NMS factory settings Figure 8-36 NMS System Reboot & Factory Setting (Control – NMS) Advanced RF Technologies, Inc. 86 8.2.3.2 Control – BCU Figure 8-37 Control – BCU 8.2.3.2.1 Manual ATT Control Figure 8-38 Control – BCU Manual ATT Control Downlink: Allows the user to manually adjust the DL attenuation levels for each RF path. Adjusting these settings is not recommended since it will change the power ratios set by the user. Uplink: Allows the user to manually adjust the UL attenuation levels for each RF path. Adjusting these settings is not recommended, unless additional attenuation is needed on the UL path. DL Output ALC Level: Allows the user to manually set the DL Output ALC Levels for each RF path. Adjusting these settings is not recommended since it will change the power ratios set by the user. These settings are automatically set by the system during the BCU commissioning process. This section also displays the composite DL Output ALC Level which is the value that can be used to commission the RFU. Advanced RF Technologies, Inc. 87 8.2.3.2.2 Reboot / Factory Setting Allows the user reboot or restore factory settings of the BCU. Figure 8-39 Control – BCU Reboot/Factory Setting 8.2.3.2.3 Alarm Setting Figure 8-40 Control – BCU Alarm Setting Downlink Input Overload: Allows the user to specify the level at which the DL Input Overload alarm is triggered. Values range from 0 dBm to +25 dBm. Downlink Signal Low: Allows the user to specify the level at which the DL Signal Low alarm is triggered. Values range from -10 dBm to +20 dBm. Downlink Input Overload Alarm On: Allows to user to enable or disable the Input Overload Alarm [Path – A/B/C] Downlink Signal Low Alarm On: Allows the user to enable or disable the DL Signal Low alarm for each RF path. 8.2.3.3 Control – RFU Figure 8-41 Control - RFU Advanced RF Technologies, Inc. 88 8.2.3.3.1 General Setting To enable any of the settings, click on the checkbox and click the Apply button. Figure 8-42 General Setting (Control – RFU) (Admin) Figure 8-43 General Setting (Control – RFU) (User) Table 8-14 Name Description for General Setting Description Available Accounts Downlink ALC Enables or disables Downlink ALC Uplink ALC Downlink ON Enables or disables Uplink ALC Enables or disables the RFU Downlink path Administrator Administrator, User Enables or disables the RFU Uplink path Administrator, User Uplink ON Uplink Noise Det 8.2.3.3.2 Administrator Displays if the module is turned on or off due to the UL Noise Detection Routine Reboot / Factory Setting Allows the user reboot or restore factory settings of the RFU. Figure 8-44 Reboot & Factory Setting (Control – RFU) 8.2.3.3.3 Uplink Noise Detection (Admin Only) Figure 8-45 UL Noise Detection (Control – RFU) Advanced RF Technologies, Inc. 89 Administrator The “UL Noise Det” button will take you to the UL Noise Detection page which will allow you to run the UL Noise Detection routine. Figure 8-46 UL Noise Detection - PCS band The Auto UL noise measurement routine can be run by clicking on the Check button. After all UL noise measurement have been taken, the levels for each UL path will be displayed and along with the difference between minimum detect level and measured detect level. The user will be able to see which path is generating the elevated UL noise level based on the measured detect level and difference value. To navigate back to the RFU control page, click on the Control tab again. 8.2.3.3.4 Manual Atten Control (Admin) (User) Figure 8-47 Manual Attenuator Control Setting (Control – RFU) Table 8-15 Description for Main Gain Control Setting (Control – RFU) Name Description Range Step Available Accounts Downlink Atten Downlink Attenuator to be adjusted manually 0 ~ 25dB 0.5dB Administrator, User Uplink Atten DL Output ALC Level Uplink Attenuator to be adjusted manually To set the Max output ALC level 0 ~ 35dB -10 ~ 0dBm 0.5dB 0.5dBm Administrator, User Administrator UL Output ALC Level To set the Max output ALC level -20 ~ 0dBm 0.5dBm Administrator, User Advanced RF Technologies, Inc. 90 DL Output ALC Offset To set the Max output ALC Offset -10 ~ 0dBm 0.5dBm Administrator UL Output ALC Offset To set the Max output ALC Offset -20 ~ 0dBm 0.5dBm Administrator 8.2.3.3.5 Alarm Setting Figure 8-48 Alarm Threshold Setting (Control – RFU) Table 8-16 Name Downlink Signal Low Downlink Signal Not Detected Uplink Over Power Description for Alarm Threshold Setting (Control – RFU) Description Allows the user to specify the minimum incoming DL input signal level before triggering a “Downlink Signal Low” soft-fail alarm. Allows the user to specify the minimum incoming DL input signal level before triggering a “Downlink Signal Not Detected” soft-fail alarm. Allows the user to specify the how strong the output signal of uplink can be before triggering an “Uplink Over Power” Hard Fail alarm. Advanced RF Technologies, Inc. 91 Range Default threshold -10 ~ 20dBm -5dBm -10 ~ 20dBm -10dBm -20 ~ 0dBm 0dBm 8.2.3.4 Control – ODU Figure 8-49 Control – ODU 8.2.3.4.1 Optic Attenuation (Admin Only) Figure 8-50 Optic Attenuation – ODU Advanced RF Technologies, Inc. 92 Table 8-17 Description for Optic Attenuation (Control – ODU) Name Description DL/UL common ATT DL ATT UL ATT 8.2.3.4.2 Allows the user to control overall optic DL/UL path gain. Used to compensate DL optic loss. Used to compensate UL optic loss. Reboot/Factory Setting Allow the user to perform ODU reboot or ODU factory settings. Figure 8-51 Reboot & factory Setting (Control – ODU) 8.2.3.5 Control – RH Hub Figure 8-52 Control – HRU Hub 8.2.3.5.1 Reboot/Factory Setting Allows the user to perform HRU Hub reboot or HRU Hub factory settings Figure 8-53 Reboot & Factory Setting (Control – HRU Hub) Advanced RF Technologies, Inc. 93 Range Default threshold 0 ~ 30dB 0 ~ 13dB 0 ~ 13dB 5dB 13dB 13dB 8.2.3.6 Control – Remote Module (Master or Slave RU) Figure 8-54 Control – Remote Module 8.2.3.6.1 General Setting (Admin/User) (Admin) (User) Figure 8-55 Table 8-18 Name Downlink ALC Downlink On Uplink ALC Uplink On General Setting (Control - RU) Description for General Setting (Control - RU) Description Available Accounts This setting allows you to enable or disable the downlink ALC function. When ALC is enabled, the downlink output power will not exceed the Downlink Output Level specified in the Manual Atten Control section. This setting allows you to enable or disable the Downlink path. This setting allows you to enable or disable the uplink ALC function. When ALC is enabled, the Uplink output power will not exceed the Uplink Output Level specified in the Manual Atten Control section. This setting allows you to enable or disable the Uplink path. Advanced RF Technologies, Inc. 94 Administrator Administrator, User Administrator Administrator, User 8.2.3.6.2 Reboot/Factory Setting Allows the user to Reboot or restore Factory Settings on the remote module. Figure 8-56 Reboot & factory Setting (Control - RU) 8.2.3.6.3 Optic Setting (Only Master RU) (Admin Only) Figure 8-57 Optic Setting (Control - RU) Table 8-19 Name Description Downlink Optic Atten PD Power LD Power 8.2.3.6.4 Description for Optic Setting (Control - RU) RF attenuator to compensate the optic loss of downlink Incoming power level from the ODU Outgoing power level to the ODU Range Step Available Accounts 0~ 13.0 dB 0.5 dB Administrator Administrator Administrator Manual Attenuator Control (Admin) (User) Figure 8-58 Manual Atten Control (Control - RU) Advanced RF Technologies, Inc. 95 Table 8-20 Name Description for Manual Atten Control (Control - RU) Description Range Default Available Accounts threshold Downlink Atten Allows the user to specify how much attenuation to use. 0 ~ 30dB 30dB Administrator, User Uplink Atten DL Output ALC Level UL Output ALC Level Allows the user to specify how much attenuation to use. The remote module will prevent the downlink output power from exceeding the specified value. The system will prevent the output power to exceed the specified value. When the incoming signal level increases, the system will not adjust the gain levels until it reaches the ALC Offset Level. When the incoming signal level increases, the system will not adjust the gain levels until it reaches the ALC Offset Level. 0 ~ 25dB 25dB Administrator, User 5~43dBm 43dBm Administrator, User 0 ~ 10dBm 5 or 6dBm Administrator 0 ~ 10dB 5dB Administrator, User 0 ~ 10dB 3dB Administrator DL Output ALC Offset UL Output ALC Offset 8.2.3.6.5 Alarm Setting Figure 8-59 Alarm Setting (Control - RU) DL Over Power Limit: The overpower alarm threshold can be adjusted from 5~43dBm. +2dB from the DL overpower limit will trigger a soft fail and >2dB will trigger a hard fail alarm VSWR Alarm ON : Enable or disables the VSWR Alarm. Advanced RF Technologies, Inc. 96 8.2.4 Install Tab 8.2.4.1 Install – NMS Figure 8-60 Install - NMS 8.2.4.1.1 HE Commissioning Status Figure 8-61 HE Commissioning Status (Install – NMS) Table 8-21 Description for HE Commissioning Status (Install – NMS) Status Installed Status Commissioning Status Display Description Physically Installed Text is black Physically Not-Installed Success Fail or not commissioned Text is gray Green Advanced RF Technologies, Inc. Gray 97 8.2.4.1.2 SNMP Figure 8-62 SNMP (Install – NMS) The SNMP section allows you to specify the Site ID and Manager IP. The Site-ID is the code that is used to identify a particular module. The Manager IP field is where the user inputs the IP address of the NOC system that is being used to monitor the SNMP traps. 8.2.4.1.3 Location This section allows the user to input the latitude and the longitude of the repeater. Figure 8-63 Location Setting (Install – NMS) Select N or S from the dropdown menu for Latitude Select E or W from the dropdown menu for Longitude Input the first 3 numbers of the latitude/longitude in the text area after the “+” and before the “.” Input the last 6 numbers of the latitude/longitude in the text area after the “.” 8.2.4.1.4 External Modem Box Settings This section allows the user to specify an alternative IP, Subnet Mask, and Gateway settings. These settings are enabled when the Host/Remote switch is set to the Remote position. Figure 8-64 External Modem Box Setting (Install – NMS) 8.2.4.1.5 Description Advanced RF Technologies, Inc. 98 This section allows the user to save the description of NMS. Figure 8-65 Description (Install – NMS) 8.2.4.1.6 SNMP Agent False Alarm Test This section allows the user to generate both soft and hard fail alarms. After alarms are generated, the NOC can poll the ADX to see if alarms are present. All alarms generated during this test are false alarms. Figure 8-66 SNMP Agent False Alarm Test (Install – NMS) 8.2.4.1.7 Location Info / Installer Info This section allows the user to specify the address of the repeater and also the information of the installer. Figure 8-67 Location Info / Installer Info (Install – NMS) Advanced RF Technologies, Inc. 99 8.2.4.1.8 Date & Time This section allows the user to specify the current date and time. Figure 8-68 Date & Time Setting (Install – NMS) 8.2.4.2 Install – BCU Figure 8-69 Install – BCU Advanced RF Technologies, Inc. 100 8.2.4.2.1 BCU Commissioning Figure 8-70 Install – BCU Commissioning 8.2.4.2.2 Current DL Input Level: DL Input Commissioning Level: Targeted DL Output Power Ratio: Commissioning Progress: Previous DL Commissioning Level: Last Commissioning Date: Last Commissioning Time: Description Figure 8-71 Install – BCU Description BCU: This section allows the user to set the description of BCU. Path A/B/C: Allows the user to specify a name for each RF path. The names of each RF path will appear in the column headers. 8.2.4.3 Install – RFU Advanced RF Technologies, Inc. 101 Figure 8-72 Install - RFU Advanced RF Technologies, Inc. 102 8.2.4.3.1 RFU Commissioning This section allows the user to perform RFU commission. To perform RFU commissioning, select a DL Input Commissioning Level from the dropdown menu and click Apply. The commissioning progress is displayed on the Commissioning Progress bar. Any errors, warnings, and messages will appear via a popup window. Please refer to the ADX Installation Guide to determine the proper RFU commissioning levels. Figure 8-73 RFU Commissioning (Install – RFU) 8.2.4.3.2 Description This section allows the user to set the description of RFU. Figure 8-74 Description (Install – RFU) 8.2.4.4 Install – ODU Figure 8-75 Install – ODU 8.2.4.4.1 Optic Commissioning This section will allow the user to perform any optic compensation if it is necessary. The Commissioning button will turn orange if optic compensation is needed. Advanced RF Technologies, Inc. 103 Figure 8-76 Optic control (Control – ODU) Table 8-22 Description for Optic control (Control – ODU) Display & Control Description Optic loss is less than 5dBo Optic loss is more than 5dBo Not connected to a RU No optic loss compensation is needed. Optic loss compensation is needed. Not connected to a RU 8.2.4.4.2 Description This section allows the user to save the description of ODU. Figure 8-77 Description (Install – ODU) 8.2.4.5 Install – HRU Hub Advanced RF Technologies, Inc. 104 Figure 8-78 Install-RU Hub 8.2.4.5.1 RU Commissioning Status Figure 8-79 RU Commissioning Status (Install-RU Hub) Table 8-23 Description for HRU Commissioning status Status Installed Status Commissioning Status 8.2.4.5.2 Display Physically Installed Physically Not-Installed Success Fail or not commissioned Description This section allows the user to save the description of HRU Hub. Figure 8-80 Description (Install-RU Hub) 8.2.4.6 Install – Remote Module (Master or Slave RU) Advanced RF Technologies, Inc. Description Text is black Text is gray Green Gray 105 Figure 8-81 Install-Remote Module 8.2.4.6.1 RU Output Commissioning This section allows the user to perform HRU commission. To perform HRU commission, select a DL Output Commissioning Level from the dropdown menu and then click Apply. The commissioning progress is displayed on the Commissioning Progress bar. Any errors, warnings, and messages will appear via a popup window. Figure 8-82 RU Output Commissioning (Install-RU) Advanced RF Technologies, Inc. 106 8.2.4.6.2 Description This section allows the user to save the description of remote module. Figure 8-83 Description (Install-Remote Module) 8.2.5 System The System tab allows the user to perform firmware updates, upload closeout packages, view any changes to the system, backup existing configuration, and add/remove user accounts, and change the login credentials of the Administrator. 8.2.5.1 System: Account 8.2.5.1.1 System: Account - Account Management (Admin Only) The Account Management section allows the Administrator to delete any user/guest account. Please note that the Account Management section is only available if you are logged into the system as the Administrator. To delete a user/guest account click on the Account Management link and under the Delete column, click on the delete button. Figure 8-84 Account Management 8.2.5.1.2 System: Account - New Account (Admin Only) The New account section allows the Administrator to create a new user/guest account. Please note that the new account section is only available if you are logged into the system as the Administrator. To create a new user/guest account click on the new account link and fill in the fields highlighted in yellow as shown below. Figure 8-85 New Account Advanced RF Technologies, Inc. 107 8.2.5.1.3 System: Account - Change Password The Change Password section allows the current user who is logged into the system to change their login credentials. Figure 8-86 Change Password 8.2.5.2 System: Logs 8.2.5.2.1 System: Logs - Event Log This section displays system events that have taken place. The Event Log displays who has made the changes, the time and date of when the event took place, and what changes were made to the system. The System Log tracks the following events: System Initiation Alarm Set Alarm Clear Figure 8-87 Event Log Advanced RF Technologies, Inc. 108 8.2.5.2.2 System: Logs - User Log This section tracks user activity within the system. The User Log displays who has made the changes, the time and date of when the event took place, and what changes were made to the system. The User Log tracks the following items: Log in / Log out activity Changes to gain/attenuation/output values System event generated by user(firmware update, backup/resote, create/delete account) DAS Navigation Tree Lock/Unlock Description change Repeater/installer information change Setting date/time Figure 8-88 User Log 8.2.5.3 System: Update To perform a firmware update, click on the System:Update tab and the following screen will show up. Figure 8-89 System update Click on the ‘Browse’ button and locate the firmware file. Click on the Update button to perform the firmware update. Once the firmware update is complete, the following message will appear. Advanced RF Technologies, Inc. 109 Figure 8-90 Message after System update is complete 8.2.5.4 System: System Information 8.2.5.4.1 System: System Information System Information Check The System Information Check button will check the ADX configuation and report possible discrepancies. System Information This section displays the general system information of the ADX DAS. Figure 8-91 System Information Advanced RF Technologies, Inc. 110 x System Notification This section is displayed only when the following conditions are present: When multiple remote modules with same frequency band exist in a RU. When the remote module does not match with the RFU being used. Figure 8-92 System Notification BOM BOM displays all parts that are connected to the ADX-H-NMS. The BOM can be downloaded as a CSV file by clicking the ‘Download’ button at the bottom right. Figure 8-93 Bill of material 8.2.5.5 System: Backup/Restore Advanced RF Technologies, Inc. 111 x Settings Backup Clicking the Backup will create a temporary backup file stored inside of the ADX. Once the file is created, it will need to be downloaded to a computer. A download button will appear after the backup file has been created. If the ADX is power cycled or rebooted, then the temporary backup file will be lost. We recommend downloading the backup file immediately after it has been created. Click on the Download button to download the backup file. Figure 8-94 Setting Backup (Before) Figure 8-95 Setting Backup (After) Setting Restore Advanced RF Technologies, Inc. 112 Restore function can be used to restore the saved settings from the backup file. Once the backup file is loaded, the tree in the figure below will appear. Check the boxes of the modules that you would like to restore and then click the “Restore” button at the bottom on this section. We recommend creating a new backup file if adding or removing modules from the ADX. Discrepancies between the backup file and the existing tree could cause restore errors. Figure 8-96 Setting Restore 8.2.5.6 System: SNMP SNMP V1/V2 This section allows you to add community strings for SNMP v1 and v2. Figure 8-97 SNMP V1/V2 Advanced RF Technologies, Inc. 113 x SNMP V3 This section allows the user to add accounts for SNMP v3. Figure 8-98 SNMP V3 8.2.5.7 System: Closeout Package The closeout package section will allow the user to upload documents to the ADX-H-NMS. The maximum file size for each upload is limited to 10 MB. The total amount of space available for uploading document is 100 MB. Please do not use this section as the primary storage location of your documents. Documents may become unavailable if the system goes down. Figure 8-99 System- Closeout Package To upload documents to the module, click on the “Browse” button and locate the file that you would like to upload, then enter in a Description of the file being uploaded. Afterwards, click on the “Add File” button to upload the file. Below is what you will see after the file upload. To delete the file, click on the delete button located in the last column. Figure 8-100 System- Closeout Package after the file upload Advanced RF Technologies, Inc. 114 8.2.6 Help If an internet connection is available, clicking on the Help Tab will redirect the user to our Technical Support page. Figure 8-101 Help 8.2.7 Logout Clicking the Logout button will log the current user off the system. 8.3 Guest Mode When logging into the system as a guest, the guest will only have read-only privileges and will not be able to make any changes to the system. Advanced RF Technologies, Inc. 115 9. SYSTEM-WIDE SPECIFICATION (TO BE CONNECTED TO HE VIA OPTIC LINE) 9.1 PCS band Item Specification Downlink 1930-1995MHz Uplink 1850-1915MHz Frequency DL Input Range at HE 0~25dBm DL 18~43dB, 0.5dB step, ATT range: 0~25dB UL -5~30dB, 0.5dB step, ATT range: 0~35dB Range Gain Accuracy ָ֦ [Y2]: Correction 14/05/08 0~15dB: < ±0.5dB, 15~35dB: < ±1.0dB Gain Flatness < ±3.0dB Composite Maximum Output Power Downlink HRU at 43dBm±2dB -15dBm±2dB ָ֦ [Y3]: Correction 14/05/08 Noise Figure @max gain 7.0dB ָ֦ [Y4]: Correction 14/05/08 VSWR < 1:1.5 EVM < 8% Optical Loss 0~5dBo(with ADX-H-ODU4)/0~10dBo(with ADX-H-ODU1) System Delay <2us @0dBo optic loss Spurious FCC, 3GPP TS 36.104, 3GPP2 C.S0010-C Operating Temperature -30-55qC Operating Humidity 5-90% Dimension (W x H x D) 12.6 x 35.5 x 11.8 in Weight 105.8 lbs.(without mounting bracket) Cooling Method Fan Mount Wall mount, Pole mount(optional) RF Connector DIN type female Weather Resistance IP56/NEMA 4X Uplink at HE 9.2 AWS band Item Frequency Downlink Advanced RF Technologies, Inc. Specification 2110-2155MHz 116 Uplink 1710-1755MHz DL Input Range at HE 0~25dBm DL 18~43dB, 0.5dB step, ATT range: 0~25dB UL -5~30dB, 0.5dB step, ATT range: 0~35dB Range Gain Accuracy ָ֦ [Y5]: Correction 14/05/08 0~15dB: < ±0.5dB, 15~35dB: < ±1.0dB Gain Flatness < ±3.0dB Composite Maximum Output Power Downlink HRU at 43dBm±2dB -15dBm±2dB ָ֦ [Y6]: Correction 14/05/08 Noise Figure @max gain 7.0dB ָ֦ [Y7]: Correction 14/05/08 VSWR < 1:1.5 EVM < 8% Optical Loss 0~5dBo(with ADX-H-ODU4)/0~10dBo(with ADX-H-ODU1) System Delay <2us @0dBo optic loss Spurious FCC, 3GPP TS 36.104, 3GPP2 C.S0010-C Operating Temperature -30-55qC Operating Humidity 5-90% Dimension (W x H x D) 12.6 x 35.5 x 11.8 in Weight 105.8 lbs.(without mounting bracket) Cooling Method Fan Mount Wall mount, Pole mount(optional) RF Connector DIN type female Weather Resistance IP56/NEMA 4X Uplink at HE 9.3 Cellular band Item Specification Downlink 869-894MHz Uplink 824-849MHz Frequency DL Input Range at HE Advanced RF Technologies, Inc. 0~25dBm 117 DL 18~43dB, 0.5dB step, ATT range: 0~25dB UL -5~30dB, 0.5dB step, ATT range: 0~35dB Range Gain Accuracy ָ֦ [Y8]: Correction 14/05/08 0~15dB: < ±0.5dB, 15~35dB: < ±1.0dB Gain Flatness < ±3.0dB Composite Maximum Output Power Downlink HRU at 43dBm±2dB -15dBm±2dB ָ֦ [Y9]: Correction 14/05/08 Noise Figure @max gain 7.0dB ָ֦ [Y10]: Correction 14/05/08 VSWR < 1:1.5 EVM < 8% Optical Loss 0~5dBo(with ADX-H-ODU4)/0~10dBo(with ADX-H-ODU1) System Delay <2us @0dBo optic loss Spurious FCC, 3GPP TS 36.104, 3GPP2 C.S0010-C Operating Temperature -30-55qC Operating Humidity 5-90% Dimension (W x H x D) 12.6 x 35.5 x 11.8 in Weight 105.8 lbs.(without mounting bracket) Cooling Method Fan Mount Wall mount, Pole mount(optional) RF Connector DIN type female Weather Resistance IP56/NEMA 4X Uplink at HE 9.4 700 band Item Specification Lower ABC 728-746MHz Upper C 746-757MHz Lower ABC 698-716MHz Upper C 776-787MHz Downlink Frequency Uplink Advanced RF Technologies, Inc. 118 DL Input Range at HE 0~25dBm DL 18~43dB, 0.5dB step, ATT range: 0~25dB UL -5~30dB, 0.5dB step, ATT range: 0~35dB Range Gain Accuracy 0~15dB: < ±0.5dB, 15~35dB: < ±1.0dB Gain Flatness Composite Maximum Output Power ָ֦ [Y11]: Correction 14/05/08 < ±3.0dB Downlink HRU at 43dBm±2dB -15dBm±2dB ָ֦ [Y12]: Correction 14/05/08 Noise Figure @max gain 7.0dB ָ֦ [Y13]: Correction 14/05/08 VSWR < 1:1.5 EVM < 8% Optical Loss 0~5dBo(with ADX-H-ODU4)/0~10dBo(with ADX-H-ODU1) System Delay <2us @0dBo optic loss Spurious FCC, 3GPP TS 36.104, 3GPP2 C.S0010-C Operating Temperature -30-55qC Operating Humidity 5-90% Dimension (W x H x D) 12.6 x 35.5 x 11.8 in Weight 105.8 lbs.(without mounting bracket) Cooling Method Fan Mount Wall mount, Pole mount(optional) RF Connector DIN type female Weather Resistance IP56/NEMA 4X Uplink at HE ָ֦ [Y14]: Add Antenna Spec. 2014/05/29 10. ANTENNA SPECIFICATIONS 10.1 Omni Antenna Frequency 698-960MHz Polarization 1710-2690MHz Vertical Gain 2dBi 3dBi VSWR <1.7:1 <1.5:1 Impedance 50: Power Rating 50W Advanced RF Technologies, Inc. 119 11. MECHANICAL DRAWING Figure 11-1 HE Drawing Advanced RF Technologies, Inc. 120 Figure 11-2 Master HRU Drawing Advanced RF Technologies, Inc. 121
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : YH Ko Create Date : 2014:05:29 17:08:28+09:00 Modify Date : 2014:05:29 17:08:28+09:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : YH Ko Title : ADX DAS HRU User Manual Creator Tool : Microsoft® Office Word 2007 Metadata Date : 2014:05:29 16:27:28+09:00 Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:d6cd6b10-a701-42e0-be4e-11548dff144d Instance ID : uuid:614f0c6f-4ddb-4ea3-b7f8-092bb8c8bda4 Page Count : 121EXIF Metadata provided by EXIF.tools