User Manual
INSTRUCTIONS FOR USE
ACCESS CONTROL SYSTEM PE3LR
WANDER MONITORING AD-CARE
Access Control Systems / Wander monitoring
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
2
www.adveez.com
SUMMARY
PE3LR / AD-CARE SYSTEM OVERVIEW P. 1
WORKING PRINCIPLE
SYSTEM COMPONENTS - READERS/CONTROLLERS/SOFTWARE P. 2
SYSTEM COMPONENTS - TAGS / CARDS / AD-CARE-W WRIST P. 4
PE3LR / AD-CARE STAND ALONE SYSTEM DETAILS P. 6
Technical specicaons PE3LR-C / AD-CARE Stand-alone controller P. 6
Wiring informaon PE3LR-C / AD-CARE Stand-alone controller P. 7
Technical specicaons PE3LR-E external reader P.10
POSITIONNING CONTROLLER / EXTERNAL ANTENNA P. 11
Single / Dual reader conguraon
Specic recommendaons / conguraons
Access Control Systems / Wander monitoring
FCC - 15.21 NOTE:
The user manual for an intenonal or unintenonal radiator shall cauon the user that changes or modicaons not expressly
approved by the party responsible for compliance could void the user’s authority to operate the equipment. (PE3LR-C / PE3LR-
T/ PE3LR-TCH / AD-CARE-W)
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
1
www.adveez.com
The ADVEEZ PE3LR is a hands-free access control system that combines precision, long range and 3D detecon. It oers very con-
venient and ecient access control via the ADVEEZ PE3RL-T card/tag which can be carried in a bag or pocket and sll be quickly
idened. The PE3LR is ideal for upgrading tradional key pad and card swipe systems or applicaons where hands-free access is
required including: clean rooms, hospitals, parking, entry automaon for disabled persons, etc. PE3LR system components are
compact, robust and easy to install.
By creang precise detecon zones, the ADVEEZ system avoids misdetecon, which is the main drawback of exisng systems.
All ADVEEZ Readers supports 125 kHz, in addion to Adveez hands-free tags.
The PE3LR system is also compable with all types of electronic locks (magnec locks, electro-mechanic locks, motorized locks,
etc.) and automac devices (motorized doors). It can be connected to exisng supervised access control systems as well.
ADVEEZ AD-CARE wander monitoring system is a variant of PE3LR system which takes advantage of the precise & robust ADVEEZ
detecon. AD-CARE controllers can detect people wearing the AD-CARE-W wrist within a distance of 1 m up to 4 m.
It can then send an alarm, lock the access to be monitored, send and alarm locally or remotely to pagers and access control net-
work controllers. Hands free tags can be used for passing through monitored accesses with paents & clearing alarms automac
ally.
Main controller includes reading funcon . External antenna can extend main controller detecon zone.
Easy conguraon per soware of detecon zones, enrolling of cards, wander management wrist.
PE3LR / AD-CARE SYSTEM OVERVIEW
SIMPLE, FLEXIBLE, AND RELIABLE SOLUTION
ADVEEZ TECHNOLOGY ADVANTAGES
100% Hands Free Access: accurate, long range, compable with ADVEEZ & exisng OEM access control systems
AD-CARE WANDER MONITORING SYSTEM
DETECTION PRINCIPLE PE3LR / AD-CARE
Access Control Systems / Wander monitoring
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
2
www.adveez.com
PE3LR / AD-CARE SYSTEM OVERVIEW
INSTALLATION OVERWIEW
PE3LR-C / AD-CARE-C
main controller
Request to
Exit buon input (2 wires)
PE3LR-E External antenna
wiring (passive reader)
(6 wires)
Door contact input
(2 wires)
Addional contact
Relay output 2
(2 wires)
Alarm, Display…..
Magnec Lock
Door strike
Relay output 1
(2 wires)
DATA INTERFACE OVERWIEW
WIEGAND OUTPUT
For connecon to access controllers
(2 wires / Data0-Data1)
Serial RS485 OUTPUT:
Connecon to ADVEEZ network controllers
Connecon to Nurse call systems (AD-CARE version)
(2 wires / Data0-Data1)
Local connecon to PC for stand alone mode conguraon
Access Control Systems / Wander monitoring
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
3
www.adveez.com
ands-free Access Control System PE3LR
SYSTEM COMPONENTS PE3LR / AD-CARE
INTERNAL READER—PE3LR-C / AD-CARE STAND-ALONE CONTROLLER
EXTERNAL READER / ANTENNA PE3LR-E
ORGANEEZ SUPERVISED ACCESS CONTROL MANAGEMENT (not described in present doc.)
64000 event history / 10000 users / 128 readers / TCP-IP-R-485-Radio network
SYSTEM COMPONENTS— PE3LR/AD-CARE controller & PE3LR external antenna—FCC ID: R8T-PE3LR-C
Hands-free Access Control – 1 access point
1024 cards in stand-alone version (64000 users in network version)
Program cards directly with Master Card (PE3LR-MC) or management soware via PC– USB Cable
The Internal Reader funcon PE3LR-C Door Controller allows:
-Seng hands-free access or proximity (125 kHz) control in the secured zone on the external side without
adding an addional Reader
-Enrolling badges directly via the controller
-Sensing movement direcon between PE3LR-C internal Reader and PE3LR-E external Reader
-Connecng to ADVEEZ supervised access control system in a wired RS485 mode (Ref. P3LR-C-MC) or wire-
less (ref. PE3LR-C-WL)
-connecng to exisng third party access control systems via Wiegand output
-connecng to nurse call systems (AD-CARE version)
- Waterproof and robust for outdoor installaon
- addional Hands Free / detecon zone
- ADVEEZ PE3LR-T Hands-free tag reading
- 125 KHz EM4100, 4200, 4450 Marin card reading
Access Control Systems / Wander monitoring
PE3LR-PLG-WANDER-MONITORING (AD-CARE)
- Enroll & Delete cards / wrist
- Download logged events
- Congure access control (relay output) & alarm clear-
PE3LR-PLG (PE3LR ACCESS CONTROL)
- Enroll & Delete cards
- Download logged events
- Congure access control (relay output)
STAND ALONE CONFIGURATION SOFTWARE (not described in present document)
This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two condi-
tions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation”
WARNING STATEMENT FOR MODULE:
Because of the power level and grant condions of the Zig-Bee module, the 20cm separaon distance warning statement is need-
ed. Please see below.: The antenna(s) used for this transmier must be installed to provide a minimum separaon distance of
20cm, and must not be co-located or operang in conjuncon with any other antenna or transmier.
FULL FUNCTION BENEFIT FROM PE3LR / AD-CARE WILL BE OBTAINED WITH FOLLOWING SOFTWARE
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
4
www.adveez.com
Access Control Systems / Wander monitoring
SYSTEM COMPONENTS PE3LR / AD-CARE
SYSTEM COMPONENTS—CREDENTIALS
HANDS-FREE CARD HOLDER PE3LR-TCH (FCC-ID: R8T-PE3LR-TCH*)
HANDS-FREE TAG PE3LR-T (FCC-ID: R8T-PE3LR-T*)
Carries standard swipe or RFID proximity ISO cards
CR2032 baery life: 2,000,000 hands-free tag acvaons
Combines hands-free access system with exisng swipe and magnec card
Dimensions: 86 mm / 54 mm / 0.76 mm
Black (ref: RAL9004)
CR2032 baery life: 2,000,000 hands-free tag acvaons
Tag dimensions 74 mm/ 34 mm / 10 mm
Hands-free badge color opons: Black (ref: RAL9004), Grey (ref:
RAL9006) - Red Master Tag PE3LR-T-MC enables programming tags
CAUTION:
Both hands free PE3LR-T & PE3LR-TCH work in proximity mode for access as well as for programming. Tags must
be approached to PE3LR-C, AD-CARE-C & PE3LR-E ADVEEZ logo.
Once the tag has been programmed on the system , baery must be inserted or removed & re-inserted in order
Inserng CR2032 baery
Declip tag cap and insert
baery in holder
TORX SCREW
DIAM. 2.5MM
×4
Inserng CR2032 baery:
Remove cover (4 screws -torx) and insert
baery in holder
“This device (FCC ID : R8T-PERL3-TCH) complies with part 15 of the FCC
Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any inter-
ference received, including interference that may cause undesired operation”
“This device (FCC ID : R8T-PERL3-T) complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation”
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
5
www.adveez.com
SYSTEM COMPONENTS—CREDENTIALS
TORX SCREW
DIAM. 2.5MM
×4
CAUTION:
AD-CARE-W wrist works in proximity mode for access as well as for programming. Tags must be approached to
PE3LR-C, AD-CARE-C & PE3LR-E ADVEEZ logo.
Once AD-CARE-W wrist has been programmed on the system , baery must be inserted or removed & re-
inserted in order to iniate tag rights.
Access Control Systems / Wander monitoring
SYSTEM COMPONENTS PE3LR / AD-CARE
AD-CARE-W WANDER MONITORING WRIST (FCC-ID: R8T-AD-CARE-W*)
Inserng CR1632 baery:
Remove cover (4 screws -torx), remove
printed circuit board from housing and
insert baery in holder
CR1632 baery life: 2,000,000 wander monitoring acvaons
Housing dimensions 52 mm/ 40 mm / 9,5 mm
White an-batcterial plasc housing
1 way white wrist material: Vinyl
Wrist width: 16 mm
“This device (FCC ID: R8T-AD-CARE-W) complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference re-
ceived, including interference that may cause undesired operation”
FCC - 15.21 NOTE:
The user manual for an intenonal or unintenonal radiator shall cauon the user that changes or modicaons not expressly
approved by the party responsible for compliance could void the user’s authority to operate the equipment. (PE3LR-C / PE3LR-
T/ PE3LR-TCH / AD-CARE-W)
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
6
www.adveez.com
PE3LR / AD-CARE Controller specicaons / mounng instrucons
PE3LR-C / AD-CARE-C controller (FCC-ID : R8T-PE3LR-C*)
Stand alone door controller PE3LR-C / AD-CARE (health care variant)
Programming via PC
2 frequency RF system
Both ADVEEZ hands Free + 125 kHz EM cards supported
12V/24V power supply with no conguraon needed
200 mA average current draw / 1A peak
Operang temperature : -20°C / +70°C
Protecon class: IP54
Weight: 0.200 kg
10000 users
64000 event history
RS485 network—radio network opon (PE3LR-C-WL)
2 relays / 1 door contact switch
Mounng & Dimensions
Mounng (cauon: avoid mounng close to 125kHz proximity card
readers):
1) Fit all cables with terminal appropriate terminal blocks
according wiring details in page 3
2) Mount the back cover on the wall (4 screws) and let the
Cables ed with the terminal blocks go through the back cover
3) Connect all the terminal blocks on the printed circuit board
according to wiring diagram page 3.
4) Mount and screw the front cover unit on the back cover
4 screws - 4×60 mm 4 S6 wall plugs
Access Control Systems / Wander monitoring
“This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation”
WARNING STATEMENT FOR MODULE:
Because of the power level and grant condions of the Zig-Bee module, the 20cm separaon distance warning statement is need-
ed. Please see below.: The antenna(s) used for this transmier must be installed to provide a minimum separaon distance of
20cm, and must not be co-located or operang in conjuncon with any other antenna or transmier.
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
7
www.adveez.com
Block 1 – BLUE– 4 Pins – POWER SUPPLY –RTE buon
Pin 1: Tx1
Pin 2: Tx2
Pin 3: LED Green
Pin 4: LED red
Pin 5: GROUND
Pin 6: RX
Block 2 – GREY- 6 Pins – 2 Relay / Door contact
Pin 1: RS485-B
Pin 2: RS485-A
Pin 3: GROUND
Pin 4: Door Contact
Pin 5: DATA 1 - Wiegand
Pin 6: DATA 0 - Wiegand
Block 3 – GREY - 6 contacts - COMMUNICATION
Pin 1: Relay– NO2
Pin 2: Relay - C2
Pin 3: Relay– NC2
Pin 1: Relay– NO1
Pin 2: Relay- C1
Pin 3: Relay – NC1
Block 4 – GREY– 6 contacts External Antenna
Pin 1: 12V/24V
Pin 2: GROUND
Pin 3: Request To Exit buon +
Pin 4: Request To Exit buon -
Jumper conguraon
U17 : Inline switches for indexing controllers
J3 OFF + J4 OFF single internal antenna acvaon
J3 ON + J4 OFF Both internal & external antennas acvated
J3 OFF + J4 ON Single external antenna acvaon
J3 ON + J4 ON Internal & external readers acvated—ltering of misdetec-
ons in secured zone acvated
J2 ON: long range—internal antenna
J6 ON: acvaon buzzer
J1 ON: long range acvaon external
antenna
J7 ON: acvaon de la LED
interne
J5 ON: Red LED acvated
WIRING INFORMATION—TERMINAL BLOCK DETAILS PE3LR/AD-CARE Controller
Jumper OFF Jumper ON
1
1
1
B3 B4
B2
B1
U17
Reset Buon
Connector for
USB-PC communicaon
Access Control Systems / Wander monitoring
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
8
www.adveez.com
Wiring informaon - PE3LR/AD-CARE interface to access CTL & nurse call
BLOCK 3 : NURSE CALL (ESPA4.4.4 output or POCSAG TEXT or ASCII)
Select ck box ESPA4.4.4 orPOCSAG TEXT or ASCII raw data depending on device used
Monitored access can be named
Pager Adress / groups can be selected for ESPA communicaon mode.
Protocole conguraon depending on device downstream of AD-CARE controller :
Pin 1: RS485-B
Pin 2: RS485-A
Pin 3: GROUND
Contacteur de porte
Pin 4: DATA 1 - Wiegand Access control—door controllers
Pin 5: DATA 0 - Wiegand Access control—door controllers
RS485-RS232 TX
Converter RX
446
MHz
Access Control Systems / Wander monitoring
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
9
www.adveez.com
WIRING INFORMATION—PE3LR / AD-CARE—LOCKING DEVICES / RELAYS / POWER SUPPLY
Pin 1: Relay – NO2
Pin 2: Relay - C2
Pin 3: Relay – NC2
Pin 1: Relay – NO1
Pin 2: Relay - C1
Pin 3: Relay – NC1
0V/-PWR
Block 2 – GREY - 6 contacts – 2 Relay / Contacts—Door strike conguraon (NO)
12V/+Alim
Intrusion—Alarm wiring depends on device
Manufaturer / type
+ door strike
Pin 1: Relay – NO2
Pin 2: Relay - C2
Pin 3: Relay – NC2
Pin 1: Relay – NO1
Pin 2: Relay - C1
Pin 3: Relay – NC1
0V/-PWR
Block 2 – GREY - 6 contacts – 2 Relay / Contacts—Magnec Lock conguraon (NC—permanently supplied)
12V/+PWR
Intrusion—Alarm wiring depends on device
Manufaturer / type
+ magnec lock
Pin 1: 12V/24V
Pin 2: GROUND
Pin 3: RTE Buon +
Pin 4: RTE Buon -
+ ALIM
- ALIM
+
-
Block 1 – BLUE– 4 contacts – POWER SUPPLY –RTE
Access Control Systems / Wander monitoring
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
10
www.adveez.com
WIRING INFORMATION PE3LR / AD-CARE
*Internal and External door control
PE3LR-C-MC
12V / 24V
PE3LR-E
Reading of hands free card PE3LR-T with high reading distance accuracy
PE3LR-E enables extending detecon zone by connecng it to PE3LR-C
Mounng on standard wall box– 2 screws (minimum distance from a metal surface: 5 cm)
(cauon: avoid mounng close to 125kHz proximity card readers)
Connecon via removable terminal block
2 colors (red/green) LED actuaon
Mul technology antenna
PE3LR-E EXTERNAL READER (FCC-ID : R8T-PE3LR-C*)
Removable terminal block details
Block 1 – Grey - 6 ways – Internal Reader
PIN# 1: green LED
PIN# 2: red LED
PIN# 3: Ground LED
PIN# 4: Tx1
PIN# 5: Tx2
PIN# 6: Rx1
External reader backside view / terminal block pin ordering details
Mounng 2 screws 4 mm × 60 mm on a standard recessed conduit box 67 mm diameter and 40 mm depth
Access Control Systems / Wander monitoring
“This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation”
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
11
www.adveez.com
PE3LR-C is posioned on entry on the
inside wall or on the outside wall
depending on wall metal content
Zone to be secured
The access control can work with the single door
controller/internal reader.
The following drawing shows the detecon zone
inside the ring.
In this conguraon, the access control works in both
direcon (internal and external).
The door controller / internal reader PE3LR-C must be placed
in the secured zone to prevent any risk of aack towards
controller. There is then no outside indicaon of idencaon
Bi-reader conguraon : external an-vandal device
Secured Zone/Outside view– PE3LR-E Inside view– PE3LR-C
Door controller Installaon External Reader Installaon
Single-reader conguraon - PE3LR-C / AD-CARE
External Reader
Internal Reader/ Door controller
Internal Reader/ Door controller
Door reader
Cable/External reader
Door contact switch
Electric lock
Access Control Systems / Wander monitoring
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
12
www.adveez.com
PE3LR-E located on the entrance
ZONE 1 ZONE 2
Sensing movement direcon via PE3LR-C door controller
Drawing below shows 2 separated zones, each being ed with 1 external reader close
to entrance and 1 controller/internal reader inside.
Door controller’s jumper J1 is acvated so that reader funcon gets acvated.
Door controller’s jumper J4 is deacvated so that access control is not acve on exit.
If card bearer wants to enter zone 1 with authorized card, his card is detected while
Filtering misdetecons inside the secured zone
Inhibing the detecon in a given area
Door controller’s dipswitch J1 is acvated so that reading funcon is acve.
A switch contact of exit request is connected to the Block 4. The dipswitch J4 of door
controller is deacvated to disable the access control in exit.
If card bearer being situated in zone 1 with authorized card wishes to pass the door
(controlled door) of the zone without going out, his card is detected in the intersecon
between green and orange detecon zones. The controller/internal reader will then
idenfy the passage of PE3LR-E reader in the internal detecon zone avoiding to unlock
the access.
Posioning readers of two dierent accesses
Two dierent detecon ranges can be congured on PE3LR-C
The detecon range in short distance (dipswitch J1 or J2 deacvated) is 1.5 m.
The detecon range in long distance (dipswitch J1 or J2 acvated) is 3 m.
PE3LR-C controller
Located in the zone to be secured
Access Control Systems / Wander monitoring
ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 email: contact@adveez.com
31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA
+33(0)582082193 +1 602-549-7898
13
www.adveez.com
Hands-free access control system PE3LR
ADVEEZ SUPERVISED SYSTEM : connecng PE3LR & AD-CARE controllers
Manage Access authorizaon for all card types
Control 128 doors in Radio / RJ-45 / RS-485 mode
In the radio mode, each Controller PE3LR-C-NT is a network access point
Central access control management: users, credenals, readers, etc.
Event history recording - 64000 per access controller
Connecng the Network controller to the PC via USB cable
TECHNICAL SPECIFICATIONS PE3LR-NT NETWORK CONTROL
ACCESS CONTROL SOFTWARE
-Program / Delete credenals, users, readers
-Manage Administrators rights
-Manage me intervals, schedules and holidays
-Congure Hands-free access control:
Relay acvaon duraon
Detecon distance
Soware supplied on a USB drive with a USB cable and installaon guide
PE3LR-C-NT
12V / 24V
PE3LR-E
Administrative PC
RS-485 / USB
PE3LR-NT
*ADVEEZ Connecon
*Radio / RJ-45/ RS-485 Transmission
*Door control funcon
Radio / RJ-45 / RS-485
PE3LR-NT