ADVEEZ AD-CARE-W ACTIVE TAG User Manual

ADVEEZ ACTIVE TAG

User Manual

Download: ADVEEZ AD-CARE-W ACTIVE TAG User Manual
Mirror Download [FCC.gov]ADVEEZ AD-CARE-W ACTIVE TAG User Manual
Document ID1930131
Application IDRyz43ct4989T/6/mRwEdnw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize138.65kB (1733092 bits)
Date Submitted2013-04-02 00:00:00
Date Available2013-04-02 00:00:00
Creation Date2013-03-29 10:15:26
Producing SoftwareMicrosoft® Publisher 2010
Document Lastmod2013-03-29 10:15:26
Document TitleUser Manual
Document CreatorMicrosoft® Publisher 2010
Document Author: ADVEEZ PC9

Access Control Systems / Wander monitoring
INSTRUCTIONS FOR USE
ACCESS CONTROL SYSTEM PE3LR
WANDER MONITORING AD-CARE
Access Control Systems / Wander monitoring
SUMMARY
PE3LR / AD-CARE SYSTEM OVERVIEW
P. 1
WORKING PRINCIPLE
SYSTEM COMPONENTS - READERS/CONTROLLERS/SOFTWARE
P. 2
SYSTEM COMPONENTS - TAGS / CARDS / AD-CARE-W WRIST
P. 4
PE3LR / AD-CARE STAND ALONE SYSTEM DETAILS
P. 6
Technical specifications PE3LR-C / AD-CARE Stand-alone controller
P. 6
Wiring information PE3LR-C / AD-CARE Stand-alone controller
P. 7
Technical specifications PE3LR-E external reader
P.10
POSITIONNING CONTROLLER / EXTERNAL ANTENNA
P. 11
Single / Dual reader configuration
Specific recommendations / configurations
FCC - 15.21 NOTE:
The user manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly
approved by the party responsible for compliance could void the user’s authority to operate the equipment. (PE3LR-C / PE3LRT/ PE3LR-TCH / AD-CARE-W)
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
PE3LR / AD-CARE SYSTEM OVERVIEW
ADVEEZ TECHNOLOGY ADVANTAGES
100% Hands Free Access: accurate, long range, compatible with ADVEEZ & existing OEM access control systems
The ADVEEZ PE3LR is a hands-free access control system that combines precision, long range and 3D detection. It offers very convenient and efficient access control via the ADVEEZ PE3RL-T card/tag which can be carried in a bag or pocket and still be quickly
identified. The PE3LR is ideal for upgrading traditional key pad and card swipe systems or applications where hands-free access is
required including: clean rooms, hospitals, parking, entry automation for disabled persons, etc. PE3LR system components are
compact, robust and easy to install.
By creating precise detection zones, the ADVEEZ system avoids misdetection, which is the main drawback of existing systems.
All ADVEEZ Readers supports 125 kHz, in addition to Adveez hands-free tags.
The PE3LR system is also compatible with all types of electronic locks (magnetic locks, electro-mechanic locks, motorized locks,
etc.) and automatic devices (motorized doors). It can be connected to existing supervised access control systems as well.
AD-CARE WANDER MONITORING SYSTEM
ADVEEZ AD-CARE wander monitoring system is a variant of PE3LR system which takes advantage of the precise & robust ADVEEZ
detection. AD-CARE controllers can detect people wearing the AD-CARE-W wrist within a distance of 1 m up to 4 m.
It can then send an alarm, lock the access to be monitored, send and alarm locally or remotely to pagers and access control network controllers. Hands free tags can be used for passing through monitored accesses with patients & clearing alarms automatic
DETECTION PRINCIPLE
PE3LR / AD-CARE
ally.
Main controller includes reading function . External antenna can extend main controller detection zone.
Easy configuration per software of detection zones, enrolling of cards, wander management wrist.
SIMPLE, FLEXIBLE, AND RELIABLE SOLUTION
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
PE3LR / AD-CARE SYSTEM OVERVIEW
INSTALLATION OVERWIEW
Request to
Exit button input (2 wires)
PE3LR-C / AD-CARE-C
main controller
Door contact input
(2 wires)
PE3LR-E External antenna
wiring (passive reader)
(6 wires)
Magnetic Lock
Door strike
Relay output 1
(2 wires)
Additional contact
Relay output 2
(2 wires)
Alarm, Display…..
DATA INTERFACE OVERWIEW
WIEGAND OUTPUT
For connection to access controllers
(2 wires / Data0-Data1)
Serial RS485 OUTPUT:
 Connection to ADVEEZ network controllers
 Connection to Nurse call systems (AD-CARE version)
(2 wires / Data0-Data1)
Local connection to PC for stand alone mode configuration
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
ands-free
Access
Control
Access
Systems
Control/ System
WanderPE3LR
monitoring
SYSTEM COMPONENTS PE3LR / AD-CARE
SYSTEM COMPONENTS— PE3LR/AD-CARE controller & PE3LR external antenna—FCC ID: R8T-PE3LR-C
INTERNAL READER—PE3LR-C / AD-CARE STAND-ALONE CONTROLLER
Hands-free Access Control – 1 access point
1024 cards in stand-alone version (64000 users in network version)
Program cards directly with Master Card (PE3LR-MC) or management software via PC– USB Cable
The Internal Reader function PE3LR-C Door Controller allows:
-Setting hands-free access or proximity (125 kHz) control in the secured zone on the external side without
adding an additional Reader
-Enrolling badges directly via the controller
-Sensing movement direction between PE3LR-C internal Reader and PE3LR-E external Reader
-Connecting to ADVEEZ supervised access control system in a wired RS485 mode (Ref. P3LR-C-MC) or wireless (ref. PE3LR-C-WL)
-connecting to existing third party access control systems via Wiegand output
-connecting to nurse call systems (AD-CARE version)
EXTERNAL READER / ANTENNA PE3LR-E
- Waterproof and robust for outdoor installation
- additional Hands Free / detection zone
- ADVEEZ PE3LR-T Hands-free tag reading
- 125 KHz EM4100, 4200, 4450 Marin card reading
This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation”
WARNING STATEMENT FOR MODULE:
Because of the power level and grant conditions of the Zig-Bee module, the 20cm separation distance warning statement is needed. Please see below.: The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of
20cm, and must not be co-located or operating in conjunction with any other antenna or transmitter.
FULL FUNCTION BENEFIT FROM PE3LR / AD-CARE WILL BE OBTAINED WITH FOLLOWING SOFTWARE
STAND ALONE CONFIGURATION SOFTWARE (not described in present document)
PE3LR-PLG (PE3LR ACCESS CONTROL)
PE3LR-PLG-WANDER-MONITORING (AD-CARE)
- Enroll & Delete cards
- Enroll & Delete cards / wrist
- Download logged events
- Download logged events
- Configure access control (relay output) & alarm clear-
- Configure access control (relay output)
ORGANEEZ SUPERVISED ACCESS CONTROL MANAGEMENT (not described in present doc.)
64000 event history / 10000 users / 128 readers / TCP-IP-R-485-Radio network
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
SYSTEM COMPONENTS PE3LR / AD-CARE
SYSTEM COMPONENTS—CREDENTIALS
HANDS-FREE TAG PE3LR-T (FCC-ID: R8T-PE3LR-T*)

CR2032 battery life: 2,000,000 hands-free tag activations

Tag dimensions 74 mm/ 34 mm / 10 mm

Hands-free badge color options: Black (ref: RAL9004), Grey (ref:
RAL9006) - Red Master Tag PE3LR-T-MC enables programming tags
Inserting CR2032 battery
Declip tag cap and insert
battery in holder
“This device (FCC ID : R8T-PERL3-T) complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation”
HANDS-FREE CARD HOLDER PE3LR-TCH (FCC-ID: R8T-PE3LR-TCH*)
 Carries standard swipe or RFID proximity ISO cards
TORX SCREW
DIAM. 2.5MM
×4
 CR2032 battery life: 2,000,000 hands-free tag activations
 Combines hands-free access system with existing swipe and magnetic card
 Dimensions: 86 mm / 54 mm / 0.76 mm
 Black (ref: RAL9004)
“This device (FCC ID : R8T-PERL3-TCH) complies with part 15 of the FCC
Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation”
Inserting CR2032 battery:
Remove cover (4 screws -torx) and insert
battery in holder
CAUTION:
 Both hands free PE3LR-T & PE3LR-TCH work in proximity mode for access as well as for programming. Tags must
be approached to PE3LR-C, AD-CARE-C & PE3LR-E ADVEEZ logo.
 Once the tag has been programmed on the system , battery must be inserted or removed & re-inserted in order
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
SYSTEM COMPONENTS PE3LR / AD-CARE
SYSTEM COMPONENTS—CREDENTIALS
AD-CARE-W WANDER MONITORING WRIST (FCC-ID: R8T-AD-CARE-W*)

CR1632 battery life: 2,000,000 wander monitoring activations

Housing dimensions 52 mm/ 40 mm / 9,5 mm

White anti-batcterial plastic housing

1 way white wrist material: Vinyl

Wrist width: 16 mm
TORX SCREW
DIAM. 2.5MM
×4
Inserting CR1632 battery:
Remove cover (4 screws -torx), remove
printed circuit board from housing and
insert battery in holder
“This device (FCC ID: R8T-AD-CARE-W) complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation”
CAUTION:
 AD-CARE-W wrist works in proximity mode for access as well as for programming. Tags must be approached to
PE3LR-C, AD-CARE-C & PE3LR-E ADVEEZ logo.
 Once AD-CARE-W wrist has been programmed on the system , battery must be inserted or removed & reinserted in order to initiate tag rights.
 FCC - 15.21 NOTE:
The user manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly
approved by the party responsible for compliance could void the user’s authority to operate the equipment. (PE3LR-C / PE3LRT/ PE3LR-TCH / AD-CARE-W)
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
PE3LR / AD-CARE Controller specifications / mounting instructions
PE3LR-C / AD-CARE-C controller (FCC-ID : R8T-PE3LR-C*)
Stand alone door controller PE3LR-C / AD-CARE (health care variant)
Programming via PC
2 frequency RF system
Both ADVEEZ hands Free + 125 kHz EM cards supported
12V/24V power supply with no configuration needed
200 mA average current draw / 1A peak
Operating temperature : -20°C / +70°C
Protection class: IP54
Weight: 0.200 kg
10000 users
64000 event history
RS485 network—radio network option (PE3LR-C-WL)
2 relays / 1 door contact switch
Mounting & Dimensions
Mounting (caution: avoid mounting close to 125kHz proximity card
readers):
1) Fit all cables with terminal appropriate terminal blocks
according wiring details in page 3
2) Mount the back cover on the wall (4 screws) and let the
Cables fitted with the terminal blocks go through the back cover
3) Connect all the terminal blocks on the printed circuit board
according to wiring diagram page 3.
4) Mount and screw the front cover unit on the back cover
4 screws - 4×60 mm 4 S6 wall plugs
“This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation”
WARNING STATEMENT FOR MODULE:
Because of the power level and grant conditions of the Zig-Bee module, the 20cm separation distance warning statement is needed. Please see below.: The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of
20cm, and must not be co-located or operating in conjunction with any other antenna or transmitter.
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
WIRING INFORMATION—TERMINAL BLOCK DETAILS PE3LR/AD-CARE Controller
Block 1 – BLUE– 4 Pins – POWER SUPPLY –RTE button
Pin 1: 12V/24V
Pin 2: GROUND
B2
B1
Pin 3: Request To Exit button +
Pin 4: Request To Exit button -
Block 2 – GREY- 6 Pins – 2 Relay / Door contact
Pin 1: Relay– NO2
B4
B3
Reset Button
Pin 2: Relay - C2
U17
Pin 3: Relay– NC2
Pin 1: Relay– NO1
Pin 2: Relay- C1
Connector for
USB-PC communication
Pin 3: Relay – NC1
Jumper configuration
Block 3 – GREY - 6 contacts - COMMUNICATION
Pin 1: RS485-B
Pin 2: RS485-A
Jumper OFF
Pin 3: GROUND
Jumper ON
Pin 4: Door Contact
J3 OFF + J4 OFF single internal antenna activation
Pin 5: DATA 1 - Wiegand
J3 ON + J4 OFF Both internal & external antennas activated
J3 OFF + J4 ON
Pin 6: DATA 0 - Wiegand
Single external antenna activation
Block 4 – GREY– 6 contacts External Antenna
J3 ON + J4 ON Internal & external readers activated—filtering of misdetections in secured zone activated
J2 ON: long range—internal antenna
J6 ON: activation buzzer
J1 ON: long range activation external
antenna
J7 ON: activation de la LED
interne
Pin 1: Tx1
Pin 2: Tx2
Pin 3: LED Green
Pin 4: LED red
J5 ON: Red LED activated
Pin 5: GROUND
Pin 6: RX
U17 : Inline switches for indexing controllers
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
Wiring information - PE3LR/AD-CARE interface to access CTL & nurse call
BLOCK 3 : NURSE CALL (ESPA4.4.4 output or POCSAG TEXT or ASCII)
Pin 1: RS485-B
RS485-RS232
TX
Pin 2: RS485-A
Converter
RX
446
MHz
Pin 3: GROUND
Contacteur de porte
Pin 4: DATA 1 - Wiegand Access control—door controllers
Pin 5: DATA 0 - Wiegand Access control—door controllers
Protocole configuration depending on device downstream of AD-CARE controller :
Select tick box ESPA4.4.4 orPOCSAG TEXT or ASCII raw data depending on device used
Monitored access can be named
Pager Adress / groups can be selected for ESPA communication mode.
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
WIRING INFORMATION—PE3LR / AD-CARE—LOCKING DEVICES / RELAYS / POWER SUPPLY
Block 2 – GREY - 6 contacts – 2 Relay / Contacts—Door strike configuration (NO)
+ door strike
Pin 1: Relay – NO2
12V/+Alim
Pin 2: Relay - C2
0V/-PWR
Pin 3: Relay – NC2
Pin 1: Relay – NO1
Intrusion—Alarm wiring depends on device
Pin 2: Relay - C1
Manufaturer / type
Pin 3: Relay – NC1
Block 2 – GREY - 6 contacts – 2 Relay / Contacts—Magnetic Lock configuration (NC—permanently supplied)
Pin 1: Relay – NO2
0V/-PWR
12V/+PWR
Pin 2: Relay - C2
+ magnetic lock
Pin 3: Relay – NC2
Pin 1: Relay – NO1
Intrusion—Alarm wiring depends on device
Pin 2: Relay - C1
Manufaturer / type
Pin 3: Relay – NC1
Block 1 – BLUE– 4 contacts – POWER SUPPLY –RTE
+ ALIM
Pin 1: 12V/24V
- ALIM
Pin 2: GROUND
Pin 3: RTE Button +
Pin 4: RTE Button -
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
WIRING INFORMATION PE3LR / AD-CARE
PE3LR-E EXTERNAL READER (FCC-ID : R8T-PE3LR-C*)
Reading of hands free card PE3LR-T with high reading distance accuracy
PE3LR-E enables extending detection zone by connecting it to PE3LR-C
PE3LR-C-MC
Mounting on standard wall box– 2 screws (minimum distance from a metal surface: 5 cm)
(caution: avoid mounting close to 125kHz proximity card readers)
12V / 24V
Connection via removable terminal block
2 colors (red/green) LED actuation
Multi technology antenna
PE3LR-E
Removable terminal block details
Block 1 – Grey - 6 ways – Internal Reader
*Internal and External door control
PIN# 1: green LED
PIN# 2: red LED
PIN# 3: Ground LED
PIN# 4: Tx1
PIN# 5: Tx2
PIN# 6: Rx1
External reader backside view / terminal block pin ordering details
Mounting
2 screws 4 mm × 60 mm on a standard recessed conduit box 67 mm diameter and 40 mm depth
“This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation”
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
10
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
Single-reader configuration - PE3LR-C / AD-CARE
The access control can work with the single door
PE3LR-C is positioned on entry on the
inside wall or on the outside wall
depending on wall metal content
controller/internal reader.
The following drawing shows the detection zone
inside the ring.
In this configuration, the access control works in both
Zone to be secured
direction (internal and external).
The door controller / internal reader PE3LR-C must be placed
in the secured zone to prevent any risk of attack towards
controller. There is then no outside indication of identification
Bi-reader configuration : external anti-vandal device
Inside view– PE3LR-C
Secured Zone/Outside view– PE3LR-E
Internal Reader/ Door controller
External Reader
External Reader Installation
Door controller Installation
Internal Reader/ Door controller
Door contact switch
Electric lock
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
11
www.adveez.com
Door reader
Cable/External reader
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Access Control Systems / Wander monitoring
PE3LR-E located on the entrance
PE3LR-C controller
Located in the zone to be secured
ZONE 1
ZONE 2
Sensing movement direction via PE3LR-C door controller
Drawing below shows 2 separated zones, each being fitted with 1 external reader close
to entrance and 1 controller/internal reader inside.
Door controller’s jumper J1 is activated so that reader function gets activated.
Door controller’s jumper J4 is deactivated so that access control is not active on exit.
If card bearer wants to enter zone 1 with authorized card, his card is detected while
Filtering misdetections inside the secured zone
Inhibiting the detection in a given area
Door controller’s dipswitch J1 is activated so that reading function is active.
A switch contact of exit request is connected to the Block 4. The dipswitch J4 of door
controller is deactivated to disable the access control in exit.
If card bearer being situated in zone 1 with authorized card wishes to pass the door
(controlled door) of the zone without going out, his card is detected in the intersection
between green and orange detection zones. The controller/internal reader will then
identify the passage of PE3LR-E reader in the internal detection zone avoiding to unlock
the access.
Positioning readers of two different accesses
Two different detection ranges can be configured on PE3LR-C
The detection range in short distance (dipswitch J1 or J2 deactivated) is 1.5 m.
The detection range in long distance (dipswitch J1 or J2 activated) is 3 m.
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
12
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898
Hands-free access control system PE3LR
ADVEEZ SUPERVISED SYSTEM : connecting PE3LR & AD-CARE controllers
TECHNICAL SPECIFICATIONS PE3LR-NT NETWORK CONTROL
Manage Access authorization for all card types
Control 128 doors in Radio / RJ-45 / RS-485 mode
In the radio mode, each Controller PE3LR-C-NT is a network access point
Central access control management: users, credentials, readers, etc.
Administrative PC
Event history recording - 64000 per access controller
PE3LR-NT
Connecting the Network controller to the PC via USB cable
RS-485 / USB
*ADVEEZ Connection
*Radio / RJ-45/ RS-485 Transmission
PE3LR-NT
*Door control function
Radio / RJ-45 / RS-485
PE3LR-C-NT
12V / 24V
PE3LR-E
ACCESS CONTROL SOFTWARE
-Program / Delete credentials, users, readers
-Manage Administrators rights
-Manage time intervals, schedules and holidays
-Configure Hands-free access control:
Relay activation duration
Detection distance
Software supplied on a USB drive with a USB cable and installation guide
ADD-INS-PE3LR-CARE-ENG-31
ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163
31027 Toulouse Cedex 3 FRANCE
+33(0)582082193
13
www.adveez.com
Subject to change without notice
email: contact@adveez.com
Phoenix, AZ USA
+1 602-549-7898

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 15
Language                        : en-US
Tagged PDF                      : Yes
Author                          : ADVEEZ PC9
Create Date                     : 2013:03:29 10:15:26+01:00
Modify Date                     : 2013:03:29 10:15:26+01:00
Producer                        : Microsoft® Publisher 2010
Creator                         : Microsoft® Publisher 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R8T-AD-CARE-W

Navigation menu