APC XS 1500 BX1500BP_EN_REV01 User Manual To The E2f62543 0382 4465 Ad3c 47fe24f655f5
User Manual: APC XS 1500 to the manual
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
® 1 2 INSTALL PEDESTAL EXTENDER INSTALL BACK-UPS AND BATTERY PACK IN PEDESTAL 3 4 CONNECT BATTERY CARTRIDGE OPERATING ENVIRONMENT w w w.apc.com 32 - 104oF (0 - 40oC) A Align ✔ Back-UPS® XS 1500 User’s Manual 5 7 CONNECT EQUIPMENT / POWER 83 BR24 BP Battery Pack Printer or Scanner SURGEONLY FAX BATTERY BACKUP Wall Outlet Building Wiring Fault TVSS GND External Disk or CD / DVD Drive Modem/ Phone/Fax 6 CONNECT PHONE/ MODEM/FAX Wall Outlet Circuit Breaker Push to Reset Phone Jack CHECK BUILDING WIRING FAULT INDICATOR If the rear panel Building Wiring Fault (red) indicator is lit, a potential shock hazard exists due to one of the following conditions: • Open or high resistance ground • Hot or neutral polarity reversed • Overloaded neutral circuit Improper building wiring should be corrected by a qualified electrician. Do not use the Back-UPS until the condition that caused the fault is corrected. Note: Improper building wiring will not prevent the Back-UPS from operating, but it will limit its protection capability. Building Wiring Fault Indicator Computer Wall Outlet Building Wiring Fault TVSS GND TVSS GND Input: 120V~ 12A, 60Hz Computer Modem Port Modem/ Phone/Fax Modem/ Phone/Fax 12 ✔ ✘ B Slide Together CONNECT BACK-UPS TO BATTERY PACK Data Port 24 inches 60 cm Monitor 13 INSTALL SOFTWARE ON COMPUTER Follow the on-screen instructions. CONNECT TVSS GROUND The Back-UPS features a transient voltage surge-suppression (TVSS) screw for connecting the ground lead on additional surge suppression devices such as network and data line surge protectors. NOTE: Macintosh Users - for full USB performance, use OS 9.22 or higher. There are four status indicators (lights) on the front panel of the Back-UPS (On Line, On Battery, Overload, and Replace Battery). If Autoplay is not enabled on the computer, proceed as follows: TVSS GND 1. On the computer desktop of the display, doubleclick on My Computer. 2. Double-click on the CD-ROM drive icon and follow the on-screen instructions. Modem/ Phone/Fax To Computer USB Port USB RJ-45 Data Port 10 11 ORIENTATION BR24BP Battery Pack ✘ Computer ✔ ✔ SWITCH ON THE BACK-UPS Note: Allow the Back-UPS to charge for a full eight (8) hours prior to use. • When Self-Test has successfully completed, only the green On Line indicator will be lit. Press the front panel Power ON/OFF switch and observe that the following events occur after pressing and releasing the switch: • If the battery cartridges are not connected (see Step 3 above), the green On Line indicator and red Replace Battery indicators will light. The Back-UPS will also emit a chirping sound. • The green On Line indicator flashes. • The yellow On Battery indicator lights while a Self-Test is being performed. On Battery (yellow) - is lit whenever the battery of the Back-UPS is powering equipment connected to the Battery Backup Outlets. Four Beeps Every 30 Seconds - this alarm is sounded whenever the Back-UPS is running On Battery. Consider saving work in progress. Overload (red) - is lit whenever power demand has exceeded the capacity of the Back-UPS. Continuous Tone - this alarm is sounded whenever the Battery Backup outlets are overloaded. On Line Overload From Data Line TVSS CONNECT INTERFACE CABLE STATUS INDICATORS AND ALARMS On Battery Wall Outlet 9 Replace Battery On Line (green) - is lit whenever utility power is powering the Battery Backup outlets. Continuous Beeping - this alarm is sounded whenever a low battery condition is reached. Battery run-time is very low. Promptly save any work in progress and exit all open applications. Shutdown the operating system, computer and the Back-UPS. Circuit Breaker - the circuit breaker button located on the rear panel of the Back-UPS will stick out if an overload condition forces the BackUPS to disconnect itself from utility power. If the button sticks out, disconnect non-essential equipment. Reset the circuit breaker by pushing the button inward. Replace Battery (red) - is lit whenever the battery is near the end of its useful life, or if the battery is not connected (see above). A battery that is near the end of its useful life has insufficient run-time and should be replaced. Chirps for 1 Minute Every 5 Hours - this alarm is sounded whenever the battery has failed the automatic diagnostic test. SPECIFICATIONS TROUBLESHOOTING Problem Back-UPS will not switch on. Possible Cause Ensure the Back-UPS is securely connected to an AC outlet. Back-UPS circuit breaker “tripped”. Disconnect non-essential equipment from the Back-UPS. Reset (push in) the rear panel circuit breaker. Switch on the Back-UPS and plug in devices one at a time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip. Utility input voltage quality is out of range. Back-UPS does not power essential equipment during an outage. Back-UPS operates on battery although utility power exists. Equipment plugged into a Surge Only outlet. Back-UPS circuit breaker “tripped”. Utility input voltage quality is out of range. Back-UPS does not provide expected backup time. Item Corrective Action Back-UPS not connected to AC power source. Consider adjusting the transfer voltage and sensitivity. See Transfer Voltage and Sensitivity Adjustment. Unplug device from 'Surge Only' outlet and move to a 'Battery Backup' outlet. Disconnect non-essential equipment from the Back-UPS. Reset (push in) the rear panel circuit breaker. Switch the Back-UPS on and plug equipment in one-at-a-time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip. Consider adjusting the transfer voltage and sensitivity. See Transfer Voltage and Sensitivity Adjustment. Back-UPS is heavily loaded. Unplug non-essential equipment (printers, scanners, etc) from the Battery Backup outlets and plug into 'Surge Only' outlets. Back-UPS battery cartridge is discharged due to recent power outage and has not had time to recharge. Charge the battery cartridge for 8 hours. Back-UPS runtime is reduced until the battery cartridge is fully charged. Battery has reached the end of its life. Replace battery cartridge (see Order Replacement Battery Cartridge). Red Replace Battery indicator is flashing. Green On Line indicator is on. Internal battery cartridge is not connected. Connect battery cartridge (see Connect Battery Cartridge). Red Replace Battery indicator is on. Battery has reached the end of its life. Replace the battery cartridge (see Order Replacement Battery Cartridge). Red Overload indicator is on or flashing. Connected equipment is drawing more power than the Back-UPS can provide. Move one or more equipment power plugs from Battery Backup outlets to Surge Only outlets. Green On Line indicator is on and all other front panel indicators are flashing. Internal UPS fault. Contact APC Technical Support (see Contact Information). SERVICE On-line Input Voltage Range (default setting) 88 - 139 Vac Automatic Voltage Regulation (AVR) On-line Frequency Range The battery cartridge in the Back-UPS typically lasts 3-6 years, shorter if subjected to frequent outages or elevated temperatures. Note: Batteries in the battery pack are not user-replaceable. The battery cartridge and battery pack can be ordered online at www.apc.com. For the Back-UPS, order part number RBC33; for the battery pack order BR24BP. Please recycle spent battery cartridges. 1. 2. 3. +12% 47 - 63 Hz (autosensing) On-battery Waveshape Stepped Sine Wave Maximum Load 1500 VA - 865 W Typical Recharge Time 24 Hours Operating Temperature 32o to 104oF o 23o to The standard warranty is two (2) years from the date of purchase. APC’s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement unit to the customer. 113oF -5o to 45oC Operating / Storage Relative Humidity Size (H x W x D) 0 to 95% non-condensing 14.6 x 6.8 x 13.1 inch 37.1 x 17.2 x 33.3 cm Weight 52.5 lbs (23.5 kg) Shipping Weight 58.5 lbs (26.5 kg) CONTACT INFORMATION FCC / DOC Class B Certified On Battery Run-Time See http://www.apc.com/product TRANSFER VOLTAGE AND SENSITIVITY ADJUSTMENT In situations where the Back-UPS or connected equipment appears too sensitive to input voltage, it may be necessary to adjust the transfer voltage. This is a simple task requiring use of the front panel pushbutton. To adjust the transfer voltage, proceed as follows: 1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a Standby Mode (no indicators lit). 2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the Back-UPS will flash to acknowledge going into Programming Mode. 3. The Back-UPS will then indicate its current Lower Transfer Voltage, as shown in the following table. Indicators Lit Lower Transfer Voltage Sensitivity Use When 1 78 Vac Low Use only for extreme conditions of low input voltage. Not recommended for computer loads. 2 83 Vac Medium Back-UPS frequently goes On Battery due to low input voltage. 3 88 Vac High (factory default) Connected equipment is sensitive to low voltage (recommended). REPLACE BATTERY CARTRIDGE Consult the Troubleshooting section to eliminate common problems. If the problem persists, go to http://www.apc.com/support/. If the problem still persists, contact APC Technical Support. • Have the Back-UPS model number, serial number and date of purchase available. Be prepared to troubleshoot the problem with an APC Technical Support representative. If this is not successful, APC will issue a Return Merchandise Authorization (RMA) number and a shipping address. LIMITED WARRANTY o 0 to 40 C Storage Temperature EMI Classification ORDER REPLACEMENT BATTERY CARTRIDGE If the Back-UPS arrived damaged, notify the carrier. If the Back-UPS requires service, do not return it to the dealer. The following steps should be taken: Specification Technical Support Internet USA / Canada Mexico Brazil Worldwide http://www.apc.com/support http://www.apc.com 1.800.800.4272 292.0253 / 292.0255 0800.12.72.1 +1.401.789.5735 4. To select 78 volts as the Lower Transfer Voltage, press the pushbutton until 1 indicator is flashing. 5. To select 83 volts as the Lower Transfer Voltage, press the pushbutton until 2 indicators are flashing. 6. To select 88 volts as the Lower Transfer Voltage, press the pushbutton until 3 indicators are flashing. 7. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds, the Back-UPS will exit Programming Mode; all indicators will extinguish. Battery Cartridge 990-2121 1/03 Copyright © 2003 American Power Conversion All rights reserved. APC, PowerChute plus Personal Edition, and Back-UPS are registered trademarks of American Power Conversion. All other trademarks are the property of their respective owners.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2002:12:19 09:32:42 Producer : Acrobat Distiller 4.0 for Windows Creator : AdobePS5.dll Version 5.0.1 Title : BX1500BP_EN_REV01.fm Modify Date : 2002:12:19 09:32:42-05:00 Page Count : 2EXIF Metadata provided by EXIF.tools