ASSALOY SCYICLS3 Microprocessor Controlled Networked Lock User Manual 11 0394 Exhibit Cover

ASSA ABLOY Inc. Microprocessor Controlled Networked Lock 11 0394 Exhibit Cover

Manual

    5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-SCYICLS3 IC: 6982A-SCYICLS3  FCC Rule Part: 15.225, 15.249 IC Radio Standards Specification: RSS-210  ACS Project Number:  11-0394   Manufacturer: Assa Abloy Model: C2-IA/IK     Manual
A8122A Pre-Launch Draft11/11Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written  permission of Sargent Manufacturing Company is prohibited. Incepta™ Series C2 with Aperio™ TechnologyMortise LockInstallation InstructionsC2
1-800-810-WIRE • www.sargentlock.com • A8122A  Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.11/11/111234567                         Table of ContentsWarning  ...................................................................................2General Description .................................................................3Specifications ..........................................................................3System Overview .....................................................................3Parts Breakdown .....................................................................4Lock Installation ......................................................................6Maintenance  .........................................................................14Operational Check  ................................................................15Lock LED Indications  ............................................................16Changes or modications to this device not expressly approved by ASSA ABLOY could void the user’s authority to operate the equipment.Warning 1FCC:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.Industry Canada:This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que lapuissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Any retrot or other eld modication to a re rated opening can potentially impact the re rating of the opening, and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specic situation. When retrotting any portion of an existing re rated opening, or specifying and installing a new re-rated opening, please consult with a code specialist or local code ofcial (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.89!
11/11/111-800-810-WIRE • www.sargentlock.com • A8122A        3Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series C2 Mortise Lock  Warning: SARGENT Mfg. Co. Incepta Series C2 locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications.System Overview4!To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.SpecificationsGeneral Description23The SARGENT® Incepta Series C2 lock with Aperio™ Technology makes it easy and cost-effective to bring access control to doors. It uses local wireless communication between the lock and an Aperio hub to con-nect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door. The Incepta Series C2 utilizes HID® iCLASS® 13.56 MHz smart card tech-nology and all technology features are supported by the physical security of SARGENT ANSI/BHMA Grade 1 hardware.This product is operated by six (6) “AA” alkaline batteries. SARGENT mortise locks are designed with quality components to provide high security, performance, and durability.The Incepta Series mortise lock may be used for both indoor and outdoor applications. A weather-protectivegasket is required for outdoor applications.Lock•  IEEE 802.15.4 UHF interface•  AES 128 bit encryptionCredential Support•  HID 13.56 MHz iCLASS (full authentication, all formats)When a user presents a supported credential to the lock, the Aperio system is designed to send the credential wirelessly to the Aperio Hub. The Aperio Hub (wired through RS-485 or  Wiegand) then communicates with an EAC (Electronic Access Control) system. The EAC system provides the access decision to the Aperio Hub where access to the lock is either granted or denied.    Access Control PanelAperio Hub Electronic Access Control SystemTCP/IPRS-485/WiegandIEEE 802.15.4  (2.4GHz)
4          1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.11/11/11 Profile Series C2 Mortise Lock  Parts Breakdown13.56 MHz iCLASS                 54123567896103141516161719182022 222120Tools Required:•  #2 Phillips screwdriver•  Flat head•  T10 Torx Driver•  Security allen wrench (provided)
11/11/111-800-810-WIRE • www.sargentlock.com • A8122A        5Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series C2 Mortise Lock  1 52-4481 Reader Assembly 12 52-1332 Gasket (Optional) 13 52-2847 Conduit Pack (Optional) 14 52-1370 Fire Shield 15 52-1327 Mounting Plate 16 52-4488 Screw Pack 17 52-4486 Controller Module 18 01-0898 AA battery 69 52-4483 Inside Cover Assembly 110 52-4321 Door Position Switch Pack 111 A8120  Field Prep Template (not shown) 112 4697 Door Manufacturers Template (not shown) 113 A8122 Instructions (not shown) 114 C2-7976-hand-finish Lock body with dead bolt with Cylinder 1C2-7977-hand-finish Lock body with dead bolt without CylinderC2-7978-hand-finish Lock body without dead bolt with CylinderC2-7979-hand-finish Lock body without dead bolt without Cylinder15 79-0035 Without dead bolt 179-0036 With dead bolt (shown) 116 77-4236 Mortise Screw Pack - Specify Finish (Includes: Wood and Metal Lock body Screws, Faceplate Screws, and Strike Screws)117 Consult Factory #41 Mortise Cylinder 118 13-2131 97 Ring 119 77-4081 130W Turn Lever 120 Consult Factory Reference Incepta Catalog 121 78-3696 O-rose 122 79-2162 Trim Pack 1   ITEM PART NO. DESCRIPTION QTY.  Parts Breakdown 13.56 MHz iCLASS (Continued)
6          1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.11/11/11 Profile Series C2 Mortise Lock  A.   Verify Hand and Bevel of DoorStand on outside of locked door when determining door hand.Lock InstallationLH Left Hand Hinges Left Open Inward LHRB Left Hand Reverse Bevel Hinges Left Open Outward RHRight Hand Hinges Right Open Inward RHRB Right Hand Reverse Bevel Hinges Right Open Outward Fig. 1A1   Prepare Door6B. Door PreparationPrior to installation, all holes must be free of burrs, debris and sharp edges. Prepare door according to appropriate template (see website www.intelligentopenings.com).•  Field Template: A8120 (ships with product)•  Door Manufacture’s Template: 4697Through-bolt HoleThumb Turn Lever Hole Outside Cylinder Hole(only with cylinder installation)Outside of DoorInside of DoorRibbon Cable Hole Lever Handle HoleThrough-bolt HoleRibbon Cable Hole  Inside of Lock body Wire HoleLever Handle HoleThrough-bolt HoleMortisedPocketThumb Turn Lever HoleFig. 1BExternal DPS Hole
11/11/111-800-810-WIRE • www.sargentlock.com • A8122A        7Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series C2 Mortise Lock  2   How to Change Hand of Lock body1.  Position lock body so the red surface of the locking piece is visible.2.  Insert blade type screwdriver into locking piece slot to rotate  locking piece.3.  Push locking piece toward the back of the lock body and rotate the locking piece 180° until RED surface is on opposite side.Note: Red indicates locked (outside) side.  Fig.  2AA.  Reverse Lock Hand1.  Rotate the latchbolt 180°.2.  Flip deadlatch by hand to match bevel of latchbolt.B.   Reverse Latch HandRed locking pieceFig. 2BRed locking piece3   Install Lock body1.  Feed the wire harness through the mortise pocket and inside preparation hole as depicted in Fig. 3.2.  Carefully push the lock body into the pocket while lightly applying tension to the wire harness. Note: Do not pull the lock into the pocket with the harness alone. Ensure that the wire harness is not pinched between the lock and the mortise pocket. 3.    Insert (2) #12-24 screws into the lock body and tighten with a screw driver.Mortise  Connectors Fig. 3Inside of Door(2) #12-24 screws
8          1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.11/11/11 Profile Series C2 Mortise Lock  4   Assemble Trim1. With outside lever horizontal, insert the mounting post through outside of door and lock body.    Make certain the lever spindle is properly engaged inside the lock body (Fig 4A).2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 4B).3. Slide inside adapter and plate      assembly over spindle and secure with      (2) 8-32 X 5/8” Phillips oval head and      lock washer machine screws. Fig.  4BFig.  4A8-32 X 5/8” Phillips Oval Head and Lock WasherMachineScrewInside of DoorOutside of DoorFig. 5A Fig. 5BSet ScrewInside LeverSpindleRose1. Rotate the inside rose rst counter clock     wise  to seat the threads then clockwise      to securely tighten.2. Slide lever handle onto spindle until fully      seated. Be sure handle is horizontal and      facing the hinge side of the door. Push      lever onto spindle so minimum gap       is visible.3. Tighten the set screw securely with       a T20 Torx.4. Before closing the door, test that the     lever is functional and ensure      smooth operation of the      latchbolt.5  Install Inside Rose and Inside Lever AssemblyInside of Door
11/11/111-800-810-WIRE • www.sargentlock.com • A8122A        9Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series C2 Mortise Lock  Fig.  6B1.  Slide the spring and the rosette onto the cylinder.2.  Rotate the cylinder into cylinder hole with ngers.3.  Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole.  Note: Do not attempt to tighten all the way.4.  Verify the orientation of the cylinder has the Sargent logo as depicted in Fig. 6A.5.  Hand tighten the cylinder clamp set screw to prevent  unscrewing of the cylinder (Fig 6C).5. Test cylinder function:  •  Key retracts latchbold and deadbolt  (7976 function) •  Cylinder not present for 7977 and 7979 functions.NOTE: Use lever handle holes  to manipulate mortise to ease thread engagement of cylinder.Fig.  6COutside of DoorIMPORTANT: Position cylinder so that the SARGENT logo is positioned correctly.Correct            IncorrectFig. 6A6   Outside Cylinder Installation7  Install Thumb TurnFig.  7Thumb TurnInside of DoorCylinder Clamp-ScrewPhillips Screwdriver  1. Insert thumb turn into preparation hole and engage slot in lock body.  2. Project deadbolt  3. Orient mounting plate so screw hole is vertical (aligned with        preparation holes).  4. Secure plate with phillips screw provided.  5. Test thumb turn for function by retracting and projecting the deadbolt.Phillips screwRosetteSpringCylinder
10          1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.11/11/11 Profile Series C2 Mortise Lock  8  Attach Front PlateAttach front plate with (2) at head screws. Outside of DoorFig.  81.  FOR METAL DOORS ONLY: assemble plastic collar (not shown) to DPS sensor prior to door insertion.2.  Feed DPS wire harness through the hole in the door edge,  connector rst.3.  Pull the DPS wire harness out the door preparation hole on the inside of the door.4.  Seat the plastic DPS sensor into the door edge hole by hand.       IMPORTANT: DO NOT UTILIZE TOOLS TO SEAT SWITCH9  DPS (Door Position Switch) InstallationDoor Position Switch (DPS) Fig.  9(2) at head screws
11/11/111-800-810-WIRE • www.sargentlock.com • A8122A        11Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series C2 Mortise Lock  10  Inside Mounting Plate Installation1.  Assemble (1) washer to each through bolt (2 sets provided)2.  Insert through bolts and washers into upper and lower mounting plate holes.3.  Assemble re shield to mounting plate by aligning the mounting plate posts with holes..Mounting PlateFire shield11  Weather Conduit Installation (Optional P/N 52-2847)Fig.  10CFig.  10AInside of Door2x Through bolts2x Through boltsFig.  10Bopen slot Fig. 11AInstall weather conduit on NON FIRE-RATED exterior doors only (Fig. 11A). 1.  Carefully insert the weather conduit into the ribbon cable hole on                  the inside of the door.2.  Place the O-ring around the weather conduit on the outside and                    up against the door (Fig. 11B). Fig. 11BRibbon Cable HoleO-RingInside of Door
12          1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.11/11/11 Profile Series C2 Mortise Lock  13  Outside Reader Installation1.  Orient the reader so the HID logo is at the bottom              and the lens is at the top.2.  Feed the ribbon cable through the door (from out               side to inside).3.  Install the reader to the outside of door by aligning             the mounting posts with the door preparation holes.              Hold the reader in position with hand.4.  Tighen the (2) through bolts on the inside of the door              to secure the reader.HID ReaderOutside of Door Inside of DoorFig.  13A Fig.  13BFire-rated doors require a gasket on the outside of the door (Fig. 11A).1.  Place the gasket on the on the reader posts.2.  Continue to step 13.12  Gasket Installation (Optional P/N 52-1332)Fig. 12
11/11/111-800-810-WIRE • www.sargentlock.com • A8122A        13Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series C2 Mortise Lock  14  Configuring RX Switch Handing1.  Each lever handle has a sensor installed but only the inside lever is              utilized for RX sensing.2.  To properly congure the RX functionality, connect the terminals as              indicated below:        RH or RHRB door handing (blue to blue)        LH or LHRB door handing (yellow to blue)3.  Note: Factory default is blue to blue        IMPORTANT: grasp each connector rmly before separating.        Do not pull wires apart.Wire harnessWire harnessDPSLock body wiring15 Battery Housing Installation1.  Connect the outside reader ribbon cable to the top of the         battery housing (See Fig.15B for detail).2.  Connect the DPS wire to the 3-wire header at the lower                                   left corner of the PCB.3.  Connect the lock body harness to the 5-wire header at         the lower right corner of the PCB.        IMPORTANT: Conrm the correct connector orientation         prior to assembly. Do not force connectors.            Note: If the HID wire harness must be twisted to connect to                       the battery housing the HID reader has been installed upside                  down. Please turn the HID reader right side up and reinstall,         then connect.Lock body wiringDPSFig. 15AFig. 15BInside of DoorFig.  14
14          1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.11/11/11 Profile Series C2 Mortise Lock  16 Secure Battery Housing 1.  Position the DPS and harness below the tabs of the                        mounting plate.2.  Align the tabs of the battery housing with the tabs of the                        mounting plate. Push down.3.   Lightly press the lock harness to assemble.4.   Snap battery compartment into position.Fig. 1617  Battery Installation1.  Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly.2.   After batteries are installed an audible “beep” will sound, the lock motor will cycle and red LED lights will ash.    Fig. 17Inside of DoorInside of Door
11/11/111-800-810-WIRE • www.sargentlock.com • A8122A        15Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series C2 Mortise Lock  18  Inside Cover Installation1.  Assemble cover by hooking top edge on inside mounting plate.2.  Carefully press bottom of cover toward door without pinching any wires.3.  Secure the cover utilizing a 1/8” security Allen wrench.Fig. 18Inside Cover1/8” Security Allen ScrewInside of DoorFor battery replacement:        When replacing the  (6) “AA” alkaline batteries in the        compartment, please note batteries must be replaced within 5           minutes to prevent the internal clock from becoming inaccurate. Maintenance 7
16          1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.11/11/11 Profile Series C2 Mortise Lock  For 7976- and 7978-function mortise locks with cylinders:1.  Insert key into cylinder and rotate.There should be no friction against lock case, wire harness or any other obstructions. (Refer to Section -6 Wiring if harness friction exists).2.  Check that the key retracts the latch: The key should rotate freely.3.  Throw the deadbolt:Check that the key retracts both the deadbolt and the latch.4.  Try the inside lever:Ensure it retracts latch and deadbolt (if provided).5.  Present a valid iCLASS credential to un-lock outside lever and retract latch. Operational Check 8
11/11/111-800-810-WIRE • www.sargentlock.com • A8122A        17Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series C2 Mortise Lock  The lock has three LED lights that support an optical scheme with red, yellow and green.  The indication scheme is described by the gures below:Fig. Lock Normal operation LED indicationLock LED Indications9NOTE: When the lock mechanism is blocked (lock jammed) the knob must be turned to release it. The “Error in lock” indication is also shown instead of the POST ashes if the battery is not accepted as new after a power-on-reset.1  Lock Normal Operation LED indication2  Lock Maintenance LED Indication Some special LED indication schemes are used during lock maintenance actions:Enter configuration mode Five yellow flashes (.125 s each)Fig. Lock maintenance LED indication Card read  (congurable) Access granted,  EAC ofine or onlineAccess denied,   EAC online Access denied,  EAC ofine Lock mechanism is  blocked when closingError in lock,  maintenance required  Time to replace the battery   Battery reached end of life, lock disabledOne yellow ash (.25 second) One green ash (1 second)  One red ash (1 second)  Three red ashes (.5 s each) Continuous red ashes blocked when closing (.125 seconds every 1 second) Ten red ashes (.125 s each), maintenance required; repeated if lock can’t close Continuous yellow ashes (.25 seconds every 5 seconds) Continuous red ashes of life,  (.25 seconds every 5 seconds)
SARGENT Manufacturing100 Sargent DriveNew Haven, CT 06511 USA800-810-WIRE (9473) • www.sargentlock.comFounded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The company’s customer base includes commercial construction, institutional, and industrial markets.Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.ASSA ABLOY is the global leader in door opening solutions, dedicated tosatisfying end-user needs for security, safety and convenience. A8122A  - 11/113  Lock Self Test LED IndicationAfter replacing the battery, a Power On Self Test (POST) is performed. The result is indicated using a series of red and green LED ashes as is described by the gure below:One red, one green ash  (1 second each)   One red ash followed by 16 red or green ashes (.5 s each)Fig. Lock POST LED indicationThe rst ash is always red. If the POST fails, the color of the 16 trailing ashes indicate the status of each individual test as described by the following table: Blink Meaning if Red Code in Event Log2 Main board firmware corrupt 0x0001 3 Override list corrupt 0x00024 Production data corrupt 0x00045 Security data corrupt 0x00086 Configuration data corrupt 0x00107 Battery power low 0x00208 RFID reader circuit error 0x00409 Voltage regulator error 0x008010 Card detection circuit error 0x010011 Secure area communication error 0x020012 Secure area memory corrupt 0x040013 Secure area sensor or motor error 0x080014 Radio modem communication error 0x100015 Radio modem memory corrupt 0x200016 Radio modem configuration error 0x400017 Radio modem RF circuit error 0x8000NOTE: If the battery is not accepted as new after a power on reset, no POST is performed.                Instead, the 10 quick red ashes used to indicate Error in lock is shown.