ASSALOY SCYICLS3 Microprocessor Controlled Networked Lock User Manual 11 0394 Exhibit Cover
ASSA ABLOY Inc. Microprocessor Controlled Networked Lock 11 0394 Exhibit Cover
ASSALOY >
Manual
Certification Exhibit FCC ID: U4A-SCYICLS3 IC: 6982A-SCYICLS3 FCC Rule Part: 15.225, 15.249 IC Radio Standards Specification: RSS-210 ACS Project Number: 11-0394 Manufacturer: Assa Abloy Model: C2-IA/IK Manual 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 C2 Incepta™ Series C2 with Aperio™ Technology Mortise Lock Installation Instructions A8122A Pre-Launch Draft 11/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Table of Contents Warning . ..................................................................................2 General Description..................................................................3 Specifications...........................................................................3 System Overview......................................................................3 Parts Breakdown......................................................................4 Lock Installation.......................................................................6 Maintenance ..........................................................................14 Operational Check .................................................................15 Lock LED Indications . ...........................................................16 Warning Changes or modifications to this device not expressly approved by ASSA ABLOY could void the user’s authority to operate the equipment. 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. FCC: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Industry Canada: This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. “This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.” Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. 1-800-810-WIRE • www.sargentlock.com • A8122A Profile Series C2 Mortise Lock General Description The SARGENT® Incepta Series C2 lock with Aperio™ Technology makes it easy and cost-effective to bring access control to doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door. The Incepta Series C2 utilizes HID® iCLASS® 13.56 MHz smart card technology and all technology features are supported by the physical security of SARGENT ANSI/BHMA Grade 1 hardware. This product is operated by six (6) “AA” alkaline batteries. SARGENT mortise locks are designed with quality components to provide high security, performance, and durability. The Incepta Series mortise lock may be used for both indoor and outdoor applications. A weather-protective gasket is required for outdoor applications. Lock Credential Support • • • IEEE 802.15.4 UHF interface AES 128 bit encryption HID 13.56 MHz iCLASS (full authentication, all formats) System Overview When a user presents a supported credential to the lock, the Aperio system is designed to send the credential wirelessly to the Aperio Hub. The Aperio Hub (wired through RS-485 or Wiegand) then communicates with an EAC (Electronic Access Control) system. The EAC system provides the access decision to the Aperio Hub where access to the lock is either granted or denied. Electronic Access Control System Access Control Panel TCP/IP RS-485/Wiegand Aperio Hub Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Specifications IEEE 802.15.4 (2.4GHz) To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only. Warning: SARGENT Mfg. Co. Incepta Series C2 locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications. 1-800-810-WIRE • www.sargentlock.com • A8122A 11/11/11 Profile Series C2 Mortise Lock Parts Breakdown 13.56 MHz iCLASS 10 19 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 20 18 17 21 22 22 20 Tools Required: 16 16 14 15 1-800-810-WIRE • www.sargentlock.com • A8122A • #2 Phillips screwdriver • Flat head • T10 Torx Driver • Security allen wrench (provided) Profile Series C2 Mortise Lock Parts Breakdown 13.56 MHz iCLASS (Continued) QTY. 52-4481 Reader Assembly 52-1332 Gasket (Optional) 52-2847 Conduit Pack (Optional) 52-1370 Fire Shield 52-1327 Mounting Plate 52-4488 Screw Pack 52-4486 Controller Module 01-0898 AA battery 52-4483 Inside Cover Assembly 10 52-4321 Door Position Switch Pack 11 A8120 Field Prep Template (not shown) 12 4697 Door Manufacturers Template (not shown) 13 A8122 Instructions (not shown) 14 C2-7976-hand-finish Lock body with dead bolt with Cylinder C2-7977-hand-finish Lock body with dead bolt without Cylinder C2-7978-hand-finish Lock body without dead bolt with Cylinder C2-7979-hand-finish Lock body without dead bolt without Cylinder 15 79-0035 Without dead bolt 79-0036 With dead bolt (shown) 16 77-4236 Mortise Screw Pack - Specify Finish (Includes: Wood and Metal Lock body Screws, Faceplate Screws, and Strike Screws) 17 Consult Factory #41 Mortise Cylinder 18 13-2131 97 Ring 19 77-4081 130W Turn Lever 20 Consult Factory Reference Incepta Catalog 21 78-3696 O-rose 22 79-2162 Trim Pack 1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. DESCRIPTION PART NO. 11/11/11 ITEM Profile Series C2 Mortise Lock Lock Installation 1 Prepare Door A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. LH LHRB RH RHRB Left Hand Hinges Left Open Inward Left Hand Reverse Bevel Hinges Left Open Outward Right Hand Hinges Right Open Inward Right Hand Reverse Bevel Hinges Right Open Outward Fig. 1A B. Door Preparation Prior to installation, all holes must be free of burrs, debris and sharp edges. Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Prepare door according to appropriate template (see website www.intelligentopenings.com). • Field Template: A8120 (ships with product) • Door Manufacture’s Template: 4697 Inside of Door Outside of Door Ribbon Cable Hole External DPS Hole Through-bolt Hole Through-bolt Hole Inside of Lock body Wire Hole Outside Cylinder Hole (only with cylinder installation) Lever Handle Hole Thumb Turn Lever Hole Mortised Pocket 11/11/11 Fig. 1B Ribbon Cable Hole 1-800-810-WIRE • www.sargentlock.com • A8122A Lever Handle Hole Profile Series C2 Mortise Lock 2 How to Change Hand of Lock body A. Reverse Lock Hand 1. Position lock body so the red surface of the locking piece is visible. 2. Insert blade type screwdriver into locking piece slot to rotate locking piece. 3. Push locking piece toward the back of the lock body and rotate the locking piece 180° until RED surface is on opposite side. Note: Red indicates locked (outside) side. B. Reverse Latch Hand 1. Rotate the latchbolt 180°. Red locking piece 2. Flip deadlatch by hand to match bevel of latchbolt. Red locking piece 3 Install Lock body Fig. 2B 1. Feed the wire harness through the mortise pocket and inside preparation hole as depicted in Fig. 3. 2. Carefully push the lock body into the pocket while lightly applying tension to the wire harness. Note: Do not pull the lock into the pocket with the harness alone. Ensure that the wire harness is not pinched between the lock and the mortise pocket. 3. Insert (2) #12-24 screws into the lock body and tighten with a screw driver. Inside of Door Mortise Connectors (2) #12-24 screws Fig. 3 1-800-810-WIRE • www.sargentlock.com • A8122A 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 2A Profile Series C2 Mortise Lock 4 Assemble Trim 1. With outside lever horizontal, insert the mounting post through outside of door and lock body. Make certain the lever spindle is properly engaged inside the lock body (Fig 4A). 2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 4B). 3. Slide inside adapter and plate assembly over spindle and secure with (2) 8-32 X 5/8” Phillips oval head and lock washer machine screws. Outside of Door Inside of Door 8-32 X 5/8” Phillips Oval Head and Lock Washer Machine Screw Fig. 4B 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 4A 5 Install Inside Rose and Inside Lever Assembly 1. Rotate the inside rose first counter clock wise to seat the threads then clockwise to securely tighten. Inside of Door 2. Slide lever handle onto spindle until fully seated. Be sure handle is horizontal and facing the hinge side of the door. Push lever onto spindle so minimum gap is visible. Spindle 3. Tighten the set screw securely with a T20 Torx. Rose 4. Before closing the door, test that the lever is functional and ensure smooth operation of the latchbolt. Set Screw Fig. 5A 1-800-810-WIRE • www.sargentlock.com • A8122A Inside Lever Fig. 5B Profile Series C2 Mortise Lock 6 Outside Cylinder Installation 1. Slide the spring and the rosette onto the cylinder. 2. Rotate the cylinder into cylinder hole with fingers. 3. Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole. Note: Do not attempt to tighten all the way. 4. Verify the orientation of the cylinder has the Sargent logo as depicted in Fig. 6A. 5. Hand tighten the cylinder clamp set screw to prevent unscrewing of the cylinder (Fig 6C). 5. Test cylinder function: • Key retracts latchbold and deadbolt (7976 function) • Cylinder not present for 7977 and 7979 functions. Outside of Door NOTE: Use lever handle holes to manipulate mortise to ease thread engagement of cylinder. IMPORTANT: Position cylinder so that the SARGENT logo is positioned correctly. Rosette Spring Phillips Screwdriver Cylinder Fig. 6A Cylinder ClampScrew Fig. 6B Fig. 6C Inside of Door 7 Install Thumb Turn 1. Insert thumb turn into preparation hole and engage slot in lock body. 2. Project deadbolt 3. Orient mounting plate so screw hole is vertical (aligned with preparation holes). 4. Secure plate with phillips screw provided. 5. Test thumb turn for function by retracting and projecting the deadbolt. Phillips screw Thumb Turn Fig. 7 1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Incorrect 11/11/11 Correct Profile Series C2 Mortise Lock 8 Attach Front Plate Attach front plate with (2) flat head screws. Outside of Door (2) flat head screws 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 8 9 DPS (Door Position Switch) Installation 1. FOR METAL DOORS ONLY: assemble plastic collar (not shown) to DPS sensor prior to door insertion. 2. Feed DPS wire harness through the hole in the door edge, connector first. 3. Pull the DPS wire harness out the door preparation hole on the Door Position inside of the door. Switch (DPS) 4. Seat the plastic DPS sensor into the door edge hole by hand. IMPORTANT: DO NOT UTILIZE TOOLS TO SEAT SWITCH Fig. 9 10 1-800-810-WIRE • www.sargentlock.com • A8122A Profile Series C2 Mortise Lock 10 Inside Mounting Plate Installation Mounting Plate 1. Assemble (1) washer to each through bolt (2 sets provided) 2. Insert through bolts and washers into upper and lower mounting plate holes. 3. Assemble fire shield to mounting plate by aligning the mounting plate posts with holes.. 2x Through bolts Fig. 10A Fire shield Inside of Door 2x Through bolts open slot Fig. 10C 11 Weather Conduit Installation (Optional P/N 52-2847) Install weather conduit on NON FIRE-RATED exterior doors only (Fig. 11A). 1. Carefully insert the weather conduit into the ribbon cable hole on the inside of the door. 2. Place the O-ring around the weather conduit on the outside and up against the door (Fig. 11B). Ribbon Cable Hole O-Ring Fig. 11B Fig. 11A Inside of Door 1-800-810-WIRE • www.sargentlock.com • A8122A 11 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 10B Profile Series C2 Mortise Lock 12 Gasket Installation (Optional P/N 52-1332) Fire-rated doors require a gasket on the outside of the door (Fig. 11A). 1. Place the gasket on the on the reader posts. 2. Continue to step 13. Fig. 12 13 Outside Reader Installation 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 1. Orient the reader so the HID logo is at the bottom and the lens is at the top. 2. Feed the ribbon cable through the door (from out side to inside). 3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes. Hold the reader in position with hand. 4. Tighen the (2) through bolts on the inside of the door to secure the reader. Outside of Door Inside of Door HID Reader Fig. 13A 12 1-800-810-WIRE • www.sargentlock.com • A8122A Fig. 13B Profile Series C2 Mortise Lock Inside of Door 14 Configuring RX Switch Handing Wire harness 1. Each lever handle has a sensor installed but only the inside lever is utilized for RX sensing. 2. To properly configure the RX functionality, connect the terminals as indicated below: RH or RHRB door handing (blue to blue) LH or LHRB door handing (yellow to blue) 3. Note: Factory default is blue to blue IMPORTANT: grasp each connector firmly before separating. Do not pull wires apart. DPS Lock body wiring Fig. 14 15 Battery Housing Installation Wire harness DPS Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 1. Connect the outside reader ribbon cable to the top of the battery housing (See Fig.15B for detail). 2. Connect the DPS wire to the 3-wire header at the lower left corner of the PCB. 3. Connect the lock body harness to the 5-wire header at the lower right corner of the PCB. IMPORTANT: Confirm the correct connector orientation prior to assembly. Do not force connectors. Note: If the HID wire harness must be twisted to connect to the battery housing the HID reader has been installed upside down. Please turn the HID reader right side up and reinstall, then connect. Lock body wiring Fig. 15A 1-800-810-WIRE • www.sargentlock.com • A8122A 13 11/11/11 Fig. 15B Profile Series C2 Mortise Lock Inside of Door 16 Secure Battery Housing 1. Position the DPS and harness below the tabs of the mounting plate. 2. Align the tabs of the battery housing with the tabs of the mounting plate. Push down. 3. Lightly press the lock harness to assemble. 4. Snap battery compartment into position. 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Fig. 16 Inside of Door 17 Battery Installation 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly. 2. After batteries are installed an audible “beep” will sound, the lock motor will cycle and red LED lights will flash. Fig. 17 14 1-800-810-WIRE • www.sargentlock.com • A8122A Profile Series C2 Mortise Lock 18 Inside Cover Installation 1. Assemble cover by hooking top edge on inside mounting plate. 2. Carefully press bottom of cover toward door without pinching any wires. 3. Secure the cover utilizing a 1/8” security Allen wrench. Inside of Door Inside Cover 1/8” Security Allen Screw Fig. 18 Maintenance 1-800-810-WIRE • www.sargentlock.com • A8122A Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. For battery replacement: When replacing the (6) “AA” alkaline batteries in the compartment, please note batteries must be replaced within 5 minutes to prevent the internal clock from becoming inaccurate. 15 11/11/11 Profile Series C2 Mortise Lock Operational Check For 7976- and 7978-function mortise locks with cylinders: 1. Insert key into cylinder and rotate. There should be no friction against lock case, wire harness or any other obstructions. (Refer to Section -6 Wiring if harness friction exists). 2. Check that the key retracts the latch: The key should rotate freely. 3. Throw the deadbolt: Check that the key retracts both the deadbolt and the latch. 4. Try the inside lever: Ensure it retracts latch and deadbolt (if provided). 11/11/11 Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. 5. Present a valid iCLASS credential to unlock outside lever and retract latch. 16 1-800-810-WIRE • www.sargentlock.com • A8122A Profile Series C2 Mortise Lock Lock LED Indications 1 Lock Normal Operation LED indication The lock has three LED lights that support an optical scheme with red, yellow and green. The indication scheme is described by the figures below: Card read (configurable) One yellow flash (.25 second) Access granted, EAC offline or online One green flash (1 second) Access denied, EAC online One red flash (1 second) Access denied, EAC offline Three red flashes (.5 s each) Lock mechanism is blocked when closing Continuous red flashes blocked when closing (.125 seconds every 1 second) Ten red flashes (.125 s each), maintenance required; repeated if lock can’t close Error in lock, maintenance required Time to replace the battery Continuous yellow flashes (.25 seconds every 5 seconds) Battery reached end of life, lock disabled Continuous red flashes of life, (.25 seconds every 5 seconds) Fig. Lock Normal operation LED indication Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. NOTE: When the lock mechanism is blocked (lock jammed) the knob must be turned to release it. The “Error in lock” indication is also shown instead of the POST flashes if the battery is not accepted as new after a power-on-reset. 2 Lock Maintenance LED Indication Some special LED indication schemes are used during lock maintenance actions: Enter configuration mode Five yellow flashes (.125 s each) Fig. Lock maintenance LED indication 1-800-810-WIRE • www.sargentlock.com • A8122A 17 11/11/11 3 Lock Self Test LED Indication After replacing the battery, a Power On Self Test (POST) is performed. The result is indicated using a series of red and green LED flashes as is described by the figure below: One red, one green flash (1 second each) One red flash followed by 16 red or green flashes (.5 s each) Fig. Lock POST LED indication The first flash is always red. If the POST fails, the color of the 16 trailing flashes indicate the status of each individual test as described by the following table: Blink Meaning if Red Code in Event Log Main board firmware corrupt 0x0001 Override list corrupt 0x0002 Production data corrupt 0x0004 Security data corrupt 0x0008 Configuration data corrupt 0x0010 Battery power low 0x0020 RFID reader circuit error 0x0040 Voltage regulator error 0x0080 10 Card detection circuit error 0x0100 11 Secure area communication error 0x0200 12 Secure area memory corrupt 0x0400 13 Secure area sensor or motor error 0x0800 14 Radio modem communication error 0x1000 15 Radio modem memory corrupt 0x2000 16 Radio modem configuration error 0x4000 17 Radio modem RF circuit error 0x8000 NOTE: If the battery is not accepted as new after a power on reset, no POST is performed. Instead, the 10 quick red flashes used to indicate Error in lock is shown. SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. A8122A - 11/11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : courtney.merrick Create Date : 2011:11:23 10:06:21-05:00 Modify Date : 2011:11:23 10:06:21-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2011:11:23 10:06:21-05:00 Creator Tool : Adobe Acrobat Pro 9.0.0 Format : application/pdf Title : Microsoft Word - 11-0394 - Exhibit Cover.doc Creator : courtney.merrick Document ID : uuid:5f30db93-7b09-4bae-92ab-caa1b60db510 Instance ID : uuid:51aa022a-9425-4f61-b017-cc811d10ec61 Producer : Adobe Acrobat Pro 9.0.0 Page Count : 19EXIF Metadata provided by EXIF.tools