ASSALOY SCYICLS3 Microprocessor Controlled Networked Lock User Manual 11 0394 Exhibit Cover

ASSA ABLOY Inc. Microprocessor Controlled Networked Lock 11 0394 Exhibit Cover

Manual

Download: ASSALOY SCYICLS3 Microprocessor Controlled Networked Lock User Manual 11 0394   Exhibit Cover
Mirror Download [FCC.gov]ASSALOY SCYICLS3 Microprocessor Controlled Networked Lock User Manual 11 0394   Exhibit Cover
Document ID1590082
Application IDEJmtHz2bdIctbeYP6Upe0Q==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize188.45kB (2355607 bits)
Date Submitted2011-11-29 00:00:00
Date Available2011-11-29 00:00:00
Creation Date2011-11-23 10:06:21
Producing SoftwareAdobe Acrobat Pro 9.0.0
Document Lastmod2011-11-23 10:06:21
Document TitleMicrosoft Word - 11-0394 - Exhibit Cover.doc
Document CreatorAdobe Acrobat Pro 9.0.0
Document Author: courtney.merrick

Certification Exhibit
FCC ID: U4A-SCYICLS3
IC: 6982A-SCYICLS3
FCC Rule Part: 15.225, 15.249
IC Radio Standards Specification: RSS-210
ACS Project Number: 11-0394
Manufacturer: Assa Abloy
Model: C2-IA/IK
Manual
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
C2
Incepta™
Series C2
with Aperio™
Technology
Mortise Lock
Installation Instructions
A8122A
Pre-Launch
Draft
11/11
Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
Table of Contents
Warning . ..................................................................................2
General Description..................................................................3
Specifications...........................................................................3
System Overview......................................................................3
Parts Breakdown......................................................................4
Lock Installation.......................................................................6
Maintenance ..........................................................................14
Operational Check .................................................................15
Lock LED Indications . ...........................................................16
Warning
Changes or modifications to this device not expressly approved by ASSA ABLOY
could void the user’s authority to operate the equipment.
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
FCC:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
Interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada:
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des
règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui
peut causer l’opération peu désirée.
“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum
(or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other
users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is
not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne
d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire
les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son
gain de sorte que la
puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une
communication satisfaisante.
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening,
and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in
any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a
new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to
ensure compliance with all applicable codes and ratings.
1-800-810-WIRE • www.sargentlock.com • A8122A
Profile Series C2 Mortise Lock
General Description
The SARGENT® Incepta Series C2 lock with Aperio™ Technology makes it easy and cost-effective to bring
access control to doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access
control – the wiring at the door. The Incepta Series C2 utilizes HID® iCLASS® 13.56 MHz smart card technology and all technology features are supported by the physical security of SARGENT ANSI/BHMA Grade 1
hardware.
This product is operated by six (6) “AA” alkaline batteries. SARGENT mortise locks are designed with quality
components to provide high security, performance, and durability.
The Incepta Series mortise lock may be used for both indoor and outdoor applications. A weather-protective
gasket is required for outdoor applications.
Lock
Credential Support
•
•
•
IEEE 802.15.4 UHF interface
AES 128 bit encryption
HID 13.56 MHz iCLASS (full authentication, all formats)
System Overview
When a user presents a supported credential to
the lock, the Aperio system is designed to send
the credential wirelessly to the Aperio Hub. The
Aperio Hub (wired through RS-485 or Wiegand)
then communicates with an EAC (Electronic
Access Control) system. The EAC system provides
the access decision to the Aperio Hub where
access to the lock is either granted or denied.
Electronic Access
Control System
Access Control Panel
TCP/IP
RS-485/Wiegand
Aperio Hub
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Specifications
IEEE 802.15.4
(2.4GHz)
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
Warning: SARGENT Mfg. Co. Incepta Series C2 locksets utilizing a door position switch (DPS) are not rated for,
or intended for use in life safety applications.
1-800-810-WIRE • www.sargentlock.com • A8122A
11/11/11
Profile Series C2 Mortise Lock
Parts Breakdown
13.56 MHz iCLASS 					
10
19
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
20
18
17
21
22
22
20
Tools Required:
16
16
14
15
1-800-810-WIRE • www.sargentlock.com • A8122A
•
#2 Phillips screwdriver
•
Flat head
•
T10 Torx Driver
•
Security allen wrench
(provided)
Profile Series C2 Mortise Lock
Parts Breakdown 13.56 MHz iCLASS (Continued)
QTY.
52-4481
Reader Assembly
52-1332
Gasket (Optional)
52-2847
Conduit Pack (Optional)
52-1370
Fire Shield
52-1327
Mounting Plate
52-4488
Screw Pack
52-4486
Controller Module
01-0898
AA battery
52-4483
Inside Cover Assembly
10
52-4321
Door Position Switch Pack
11
A8120
Field Prep Template (not shown)
12
4697
Door Manufacturers Template (not shown)
13
A8122
Instructions (not shown)
14
C2-7976-hand-finish
Lock body with dead bolt with Cylinder
C2-7977-hand-finish
Lock body with dead bolt without Cylinder
C2-7978-hand-finish
Lock body without dead bolt with Cylinder
C2-7979-hand-finish
Lock body without dead bolt without Cylinder
15
79-0035
Without dead bolt
79-0036
With dead bolt (shown)
16
77-4236
Mortise Screw Pack - Specify Finish (Includes: Wood and Metal
Lock body Screws, Faceplate Screws, and Strike Screws)
17
Consult Factory
#41 Mortise Cylinder
18
13-2131
97 Ring
19
77-4081
130W Turn Lever
20
Consult Factory
Reference Incepta Catalog
21
78-3696
O-rose
22
79-2162
Trim Pack
1-800-810-WIRE • www.sargentlock.com • A8122A
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
DESCRIPTION
PART NO.
11/11/11
ITEM
Profile Series C2 Mortise Lock
Lock Installation
1 Prepare Door
A. Verify Hand and Bevel of Door
Stand on outside of locked door when determining door hand.
LH
LHRB
RH
RHRB
Left Hand
Hinges Left
Open Inward
Left Hand
Reverse Bevel
Hinges Left
Open Outward
Right Hand
Hinges Right
Open Inward
Right Hand
Reverse Bevel
Hinges Right
Open Outward
Fig. 1A
B. Door Preparation
Prior to installation, all holes must be free of burrs, debris and sharp edges.
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Prepare door according to appropriate template (see website www.intelligentopenings.com).
• Field Template: A8120 (ships with product)
• Door Manufacture’s Template: 4697
Inside of Door
Outside of Door
Ribbon Cable Hole
External DPS
Hole
Through-bolt Hole
Through-bolt Hole
Inside of Lock body
Wire Hole
Outside Cylinder Hole
(only with cylinder
installation)
Lever Handle Hole
Thumb Turn Lever Hole
Mortised
Pocket
11/11/11
Fig. 1B
Ribbon Cable Hole
1-800-810-WIRE • www.sargentlock.com • A8122A
Lever Handle Hole
Profile Series C2 Mortise Lock
2 How to Change Hand of Lock body
A. Reverse Lock Hand
1. Position lock body so the red surface of the locking piece is visible.
2. Insert blade type screwdriver into locking piece slot to rotate
locking piece.
3. Push locking piece toward the back of the lock body and rotate
the locking piece 180° until RED surface is on opposite side.
Note: Red indicates locked (outside) side.
B. Reverse Latch Hand
1. Rotate the latchbolt 180°.
Red locking
piece
2. Flip deadlatch by hand to match bevel of latchbolt.
Red locking piece
3 Install Lock body
Fig. 2B
1. Feed the wire harness through the mortise pocket and inside
preparation hole as depicted in Fig. 3.
2. Carefully push the lock body into the pocket while lightly applying
tension to the wire harness.
Note: Do not pull the lock into the pocket with the harness alone.
Ensure that the wire harness is not pinched between the lock and
the mortise pocket.
3. Insert (2) #12-24 screws into the lock body and tighten with a
screw driver.
Inside of Door
Mortise
Connectors
(2) #12-24 screws
Fig. 3
1-800-810-WIRE • www.sargentlock.com • A8122A
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 2A
Profile Series C2 Mortise Lock
4 Assemble Trim
1. With outside lever horizontal, insert the mounting post through outside of door and lock body.
Make certain the lever spindle is properly engaged inside the lock body (Fig 4A).
2. On the inside of the door, insert spindle into square hole of mortise lock (Fig 4B).
3. Slide inside adapter and plate
assembly over spindle and secure with
(2) 8-32 X 5/8” Phillips oval head and
lock washer machine screws.
Outside of Door
Inside of Door
8-32 X 5/8”
Phillips
Oval
Head and
Lock
Washer
Machine
Screw
Fig. 4B
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 4A
5 Install Inside Rose and Inside Lever Assembly
1. Rotate the inside rose first counter clock
wise to seat the threads then clockwise
to securely tighten.
Inside of Door
2. Slide lever handle onto spindle until fully
seated. Be sure handle is horizontal and
facing the hinge side of the door. Push
lever onto spindle so minimum gap
is visible.
Spindle
3. Tighten the set screw securely with
a T20 Torx.
Rose
4. Before closing the door, test that the
lever is functional and ensure
smooth operation of the
latchbolt.
Set Screw
Fig. 5A
1-800-810-WIRE • www.sargentlock.com • A8122A
Inside Lever
Fig. 5B
Profile Series C2 Mortise Lock
6 Outside Cylinder Installation
1. Slide the spring and the rosette onto the cylinder.
2. Rotate the cylinder into cylinder hole with fingers.
3. Insert key 75% of the way and utilize the key to rotate the cylinder into the rest of the cylinder hole.
Note: Do not attempt to tighten all the way.
4. Verify the orientation of the cylinder has the Sargent logo as depicted in Fig. 6A.
5. Hand tighten the cylinder clamp set screw to prevent
unscrewing of the cylinder (Fig 6C).
5. Test cylinder function:
•
Key retracts latchbold and deadbolt
(7976 function)
•
Cylinder not present for 7977 and
7979 functions.
Outside of Door
NOTE: Use lever handle holes
to manipulate mortise to ease
thread engagement of cylinder.
IMPORTANT: Position cylinder so that the
SARGENT logo is positioned correctly.
Rosette
Spring
Phillips
Screwdriver
Cylinder
Fig. 6A
Cylinder
ClampScrew
Fig. 6B
Fig. 6C
Inside of Door
7 Install Thumb Turn
1. Insert thumb turn into preparation hole and engage slot in lock body.
2. Project deadbolt
3. Orient mounting plate so screw hole is vertical (aligned with
preparation holes).
4. Secure plate with phillips screw provided.
5. Test thumb turn for function by retracting and projecting the deadbolt.
Phillips
screw
Thumb Turn
Fig. 7
1-800-810-WIRE • www.sargentlock.com • A8122A
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Incorrect
11/11/11
Correct
Profile Series C2 Mortise Lock
8 Attach Front Plate
Attach front plate with (2) flat head screws.
Outside of Door
(2) flat head screws
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 8
9 DPS (Door Position Switch) Installation
1. FOR METAL DOORS ONLY: assemble plastic collar (not shown)
to DPS sensor prior to door insertion.
2. Feed DPS wire harness through the hole in the door edge,
connector first.
3. Pull the DPS wire harness out the door preparation hole on the
Door Position
inside of the door.
Switch (DPS)
4. Seat the plastic DPS sensor into the door edge hole by hand.
IMPORTANT: DO NOT UTILIZE TOOLS TO SEAT SWITCH
Fig. 9
10
1-800-810-WIRE • www.sargentlock.com • A8122A
Profile Series C2 Mortise Lock
10 Inside Mounting Plate Installation
Mounting Plate
1. Assemble (1) washer to each through bolt (2 sets provided)
2. Insert through bolts and washers into upper and lower
mounting plate holes.
3. Assemble fire shield to mounting plate by aligning the
mounting plate posts with holes..
2x Through bolts
Fig. 10A
Fire shield
Inside of Door
2x Through bolts
open slot
Fig. 10C
11 Weather Conduit Installation (Optional P/N 52-2847)
Install weather conduit on NON FIRE-RATED exterior doors only (Fig. 11A).
1. Carefully insert the weather conduit into the ribbon cable hole on
the inside of the door.
2. Place the O-ring around the weather conduit on the outside and
up against the door (Fig. 11B).
Ribbon Cable Hole
O-Ring
Fig. 11B
Fig. 11A
Inside of Door
1-800-810-WIRE • www.sargentlock.com • A8122A
11
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 10B
Profile Series C2 Mortise Lock
12 Gasket Installation (Optional P/N 52-1332)
Fire-rated doors require a gasket on the outside of the door (Fig. 11A).
1. Place the gasket on the on the reader posts.
2. Continue to step 13.
Fig. 12
13 Outside Reader Installation
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
1. Orient the reader so the HID logo is at the bottom
and the lens is at the top.
2. Feed the ribbon cable through the door (from out
side to inside).
3. Install the reader to the outside of door by aligning
the mounting posts with the door preparation holes.
Hold the reader in position with hand.
4. Tighen the (2) through bolts on the inside of the door
to secure the reader.
Outside of Door
Inside of Door
HID Reader
Fig. 13A
12
1-800-810-WIRE • www.sargentlock.com • A8122A
Fig. 13B
Profile Series C2 Mortise Lock
Inside of Door
14 Configuring RX Switch Handing
Wire harness
1. Each lever handle has a sensor installed but only the inside lever is
utilized for RX sensing.
2. To properly configure the RX functionality, connect the terminals as
indicated below:
RH or RHRB door handing (blue to blue)
LH or LHRB door handing (yellow to blue)
3. Note: Factory default is blue to blue
IMPORTANT: grasp each connector firmly before separating.
Do not pull wires apart.
DPS
Lock
body
wiring
Fig. 14
15 Battery Housing Installation
Wire harness
DPS
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
1. Connect the outside reader ribbon cable to the top of the
battery housing (See Fig.15B for detail).
2. Connect the DPS wire to the 3-wire header at the lower
left corner of the PCB.
3. Connect the lock body harness to the 5-wire header at
the lower right corner of the PCB.
IMPORTANT: Confirm the correct connector orientation
prior to assembly. Do not force connectors.
Note: If the HID wire harness must be twisted to connect to
the battery housing the HID reader has been installed upside
down. Please turn the HID reader right side up and reinstall,
then connect.
Lock
body
wiring
Fig. 15A
1-800-810-WIRE • www.sargentlock.com • A8122A
13
11/11/11
Fig. 15B
Profile Series C2 Mortise Lock
Inside of Door
16 Secure Battery Housing
1. Position the DPS and harness below the tabs of the
mounting plate.
2. Align the tabs of the battery housing with the tabs of the
mounting plate. Push down.
3. Lightly press the lock harness to assemble.
4. Snap battery compartment into position.
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
Fig. 16
Inside of Door
17 Battery Installation
1. Place (6) “AA” alkaline batteries in the compartment, being
careful to align polarity properly.
2. After batteries are installed an audible “beep” will sound,
the lock motor will cycle and red LED lights will flash.
Fig. 17
14
1-800-810-WIRE • www.sargentlock.com • A8122A
Profile Series C2 Mortise Lock
18 Inside Cover Installation
1. Assemble cover by hooking top edge on inside
mounting plate.
2. Carefully press bottom of cover toward door without
pinching any wires.
3. Secure the cover utilizing a 1/8” security Allen wrench.
Inside of Door
Inside
Cover
1/8” Security
Allen Screw
Fig. 18
Maintenance
1-800-810-WIRE • www.sargentlock.com • A8122A
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
For battery replacement:
When replacing the (6) “AA” alkaline batteries in the
compartment, please note batteries must be replaced within 5
minutes to prevent the internal clock from becoming inaccurate.
15
11/11/11
Profile Series C2 Mortise Lock
Operational Check
For 7976- and 7978-function mortise locks with cylinders:
1. Insert key into cylinder and rotate.
There should be no friction against lock case, wire harness or
any other obstructions.
(Refer to Section -6 Wiring if harness friction exists).
2. Check that the key retracts the latch:
The key should rotate freely.
3. Throw the deadbolt:
Check that the key retracts both the deadbolt and the latch.
4. Try the inside lever:
Ensure it retracts latch and deadbolt (if provided).
11/11/11
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
5. Present a valid iCLASS credential to unlock outside lever and retract latch.
16
1-800-810-WIRE • www.sargentlock.com • A8122A
Profile Series C2 Mortise Lock
Lock LED Indications
1 Lock Normal Operation LED indication
The lock has three LED lights that support an optical scheme with red, yellow and green.
The indication scheme is described by the figures below:
Card read
(configurable)
One yellow flash (.25 second)
Access granted,
EAC offline or online
One green flash (1 second)
Access denied,
EAC online
One red flash (1 second)
Access denied,
EAC offline
Three red flashes (.5 s each)
Lock mechanism is
blocked when closing
Continuous red flashes blocked when
closing (.125 seconds every 1 second)
Ten red flashes (.125 s each), maintenance
required; repeated if lock can’t close
Error in lock,
maintenance required
Time to replace the battery
Continuous yellow flashes
(.25 seconds every 5 seconds)
Battery reached end of life,
lock disabled
Continuous red flashes of life,
(.25 seconds every 5 seconds)
Fig. Lock Normal operation LED indication
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
NOTE: When the lock mechanism is blocked (lock jammed) the knob must be turned to release it.
The “Error in lock” indication is also shown instead of the POST flashes if the battery is not accepted
as new after a power-on-reset.
2 Lock Maintenance LED Indication
Some special LED indication schemes are used during lock maintenance actions:
Enter configuration
mode
Five yellow flashes (.125 s each)
Fig. Lock maintenance LED indication
1-800-810-WIRE • www.sargentlock.com • A8122A
17
11/11/11
3 Lock Self Test LED Indication
After replacing the battery, a Power On Self Test (POST) is performed. The result is indicated
using a series of red and green LED flashes as is described by the figure below:
One red, one green flash
(1 second each)
One red flash followed by 16 red or
green flashes (.5 s each)
Fig. Lock POST LED indication
The first flash is always red. If the POST fails, the color of the 16 trailing flashes indicate the
status of each individual test as described by the following table:
Blink
Meaning if Red
Code in Event Log
Main board firmware corrupt
0x0001
Override list corrupt
0x0002
Production data corrupt
0x0004
Security data corrupt
0x0008
Configuration data corrupt
0x0010
Battery power low
0x0020
RFID reader circuit error
0x0040
Voltage regulator error
0x0080
10
Card detection circuit error
0x0100
11
Secure area communication error
0x0200
12
Secure area memory corrupt
0x0400
13
Secure area sensor or motor error
0x0800
14
Radio modem communication error
0x1000
15
Radio modem memory corrupt
0x2000
16
Radio modem configuration error
0x4000
17
Radio modem RF circuit error
0x8000
NOTE: If the battery is not accepted as new after a power on reset, no POST is performed.
Instead, the 10 quick red flashes used to indicate Error in lock is shown.
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-810-WIRE (9473) • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
ASSA ABLOY is the global leader in door opening solutions, dedicated to
satisfying end-user needs for security, safety and convenience.
A8122A - 11/11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : courtney.merrick
Create Date                     : 2011:11:23 10:06:21-05:00
Modify Date                     : 2011:11:23 10:06:21-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2011:11:23 10:06:21-05:00
Creator Tool                    : Adobe Acrobat Pro 9.0.0
Format                          : application/pdf
Title                           : Microsoft Word - 11-0394 - Exhibit Cover.doc
Creator                         : courtney.merrick
Document ID                     : uuid:5f30db93-7b09-4bae-92ab-caa1b60db510
Instance ID                     : uuid:51aa022a-9425-4f61-b017-cc811d10ec61
Producer                        : Adobe Acrobat Pro 9.0.0
Page Count                      : 19
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-SCYICLS3

Navigation menu