ASSALOY SCYPROX4 Microprocessor Controlled Networked Lock User Manual 11 0282

ASSA ABLOY Inc. Microprocessor Controlled Networked Lock 11 0282

Manual

    5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-SCYPROX4 IC: 6982A-SCYPROX4  FCC Rule Part: 15.209, 15.249 IC Radio Standards Specification: RSS-210  ACS Project Number:  11-0282.W06   Manufacturer: Assa Abloy Model: N2-PA/PK     User Manual
A8078B 08/11Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written  permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 with Aperio™ TechnologyMortise LockInstallation Instructionsv.N2
1-800-810-WIRE • www.sargentlock.com • A8078B Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.08/22/111234567                         Table of ContentsWarning  ...................................................................................2General Description .................................................................3Specifications ..........................................................................3System Overview .....................................................................3Parts Breakdown .....................................................................4Lock Installation ......................................................................6Operational Check  ................................................................14Lock LED Indications  ............................................................15Warning: Changes or modications to this device not expressly approved by ASSA ABLOY could void the user’s authority to operate the equipment.Warning 1FCC:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to which the receiv-er is connected.•  Consult the dealer or an experienced radio/TV technician for help.Industry Canada:This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.“This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.8
08/22/111-800-810-WIRE • www.sargentlock.com • A8078B       3Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 Mortise Lock  Warning: SARGENT Mfg. Co. Prole Series v.N2 locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications.System Overview4!To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.SpecificationsGeneral Description23The SARGENT® Prole Series v.N2 lock with Aperio™ Technology makes it easy and cost-effective to bring access control to additional doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door. The Prole Series v.N2 is available with HID® 125 kHz proximity or iCLASS® 13.56 MHz smart card technology, and all technology features are supported by the physical security of SAR-GENT ANSI/BHMA Grade 1 hardware.This product is operated by six (6) “AA” alkaline batteries. SARGENT mortise locks are designed with quality components to provide high security, performance and durability.The Aperio mortise lock may be used for both indoor and outdoor applications. A weather-protectivegasket is recommended for outdoor applications.Lock•  IEEE 802.15.4 UHF interface•  AES 128 bit encryptionCredential Support•  HID 13.56 MHz iCLASS (full authentication, all formats)•  125 kHz proximity credentialsWhen a user presents a supported credential to the lock, the Aperio system is designed to send the credential wirelessly to the Aperio Hub. The Aperio Hub (wired through RS-485 or  Wiegand) then communicates with an EAC (Electronic Access Control) system. The EAC system provides the access decision to the Aperio Hub where access to the lock is either granted or denied.    Access Control PanelAperio Hub Electronic Access Control SystemTCP/IPRS-485/WiegandIEEE 802.15.4  (2.4GHz)
4          1-800-810-WIRE • www.sargentlock.com • A8078B Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.08/22/11 Profile Series v.N2 Mortise Lock  Parts Breakdown57489991637921091121113151415513.56 MHz iCLASS & 125 kHz Prox                 5
08/22/111-800-810-WIRE • www.sargentlock.com • A8078B       5Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 Mortise Lock  1 Outside Lever Reference 8200 Catalog for available levers 12 Inside Lever Reference 8200 Catalog for available levers 13 82-0495 O/S Escutcheon only with Cylinder 182-0493 O/S Escutcheon only without Cylinder 14 82-0492 Inside Escutcheon only without Thumb Turn 182-0494 Inside Escutcheon only with Thumb Turn 15 52-5291 Aperio Electronic Replacement Pack, 13.56 MHz iCLASS 152-5319 Aperio Electronic Replacement Pack, Prox only, N2-PA7 52-4340 Battery Cover Assembly 18 01-1212 Security Screw 19 52-2427 Profile Screw Pack - Specify Finish (Includes: Fire Stop Plate, Trim Mounting Screws, Security Allen Wrench)110 Consult Factory Lever Handle Screw (Depends on Lever Style) 111 Consult Factory Inside Adapter Assembly (Depends on Lever Style) 112 Consult Factory Outside Adapter Assembly (Depends On Lever Style) 113 N2-82276-hand-finish Lockbody with Dead Bolt with Cylinder 1N2-82277-hand-finish Lockbody with Dead Bolt without CylinderN2-82278-hand-finish Lockbody without Dead Bolt with CylinderN2-82279-hand-finish Lockbody without Dead Bolt without Cylinder14 82-0084 Faceplate with Dead Bolt (shown) 182-0081 Faceplate without Dead Bolt 115 77-4336 Mortise Screw Pack - Specify Finish (Includes: Wood and Metal Lock body Screws, Faceplate Screws, and Strike Screws)116 Consult Factory #43 Mortise Cylinder 1   ITEM PART NO. DESCRIPTION QTY.  Parts Breakdown 13.56 MHz iCLASS and 125 kHz (Continued)
6          1-800-810-WIRE • www.sargentlock.com • A8078B Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.08/22/11 Profile Series v.N2 Mortise Lock  A.   Verify Hand and Bevel of DoorStand on outside of locked door when determining door hand.Lock InstallationLH Left Hand Hinges Left Open Inward LHRB Left Hand Reverse Bevel Hinges Left Open Outward RHRight Hand Hinges Right Open Inward RHRB Right Hand Reverse Bevel Hinges Right Open Outward Fig. 1A1   Prepare Door6B. Door PreparationPrior to installation, all holes must be free of burrs, debris and sharp edges. Prepare door according to appropriate template (see website www.intelligentopenings.com):•  Field Template: A7457 (ships with product)•  Door Manufacture’s Template: 4533Outside Cylinder Hole(only with cylinder installation)Outside of Door Inside of DoorRibbon Cable Hole (Controller to Keypad, if used)Lever Handle HoleThrough-bolt HoleRibbon Cable Hole  (Controller to Keypad)Inside of Lockbody Wire HoleLever Handle HoleThrough-bolt HolePre-drilled and/orTapped HolesMortisedPocketThumb Turn Lever HoleFig. 1BThrough-bolt HoleThrough-bolt Hole
08/22/111-800-810-WIRE • www.sargentlock.com • A8078B       7Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 Mortise Lock  2   How to Change Hand of Lock bodyBeveled surface of latchbolt must face strike.The deadlatch is self adjusting.To change the hand of the latchbolt:1.  Insert the blade of a slotted screwdriver approximately  1/4” into the spade shape slot behind latch.2.  Rotate the screwdriver 90° to push latchbolt out  until back of bolt clears lock case front.3.  Rotate latchbolt 180° until the latchbolt drops  back into the lockbody.Note: Latch cannot be unscrewed.The red surface of locking piece must face the outside/locked side of door. To rotate locking piece (Fig. 2A):1.  Position lock body so the red surface of the locking piece is visible.2.  Insert blade type screwdriver into locking piece slot to rotate locking piece toward back of lock body.3.  Rotate the locking piece 180° until RED surface is on opposite side.Note: Red indicates locked side (outside).  Push InRight Hand ShownLocking Guide SlotFig.  2AA.  Reverse Lock HandC.   Reverse Latch HandFig.  2BB.  Wire HarnessMake sure the plastic retaining ring is seated  correctly (Fig. 2B):1.  Visually note how the wires are currently routed; they must be similarly routed after changing hand to prevent dam-age caused by snagging on the cylinder cam.2.  Remove the black plastic retaining ring from the lock body.3.  Carefully pull the wires through the opposite lock body hole.4.   Position the retaining ring so that the large slot is ori-ented towards the top of the lock body.5.   Push the retaining ring into the lock body so that it fully seats as shown Fig. 2B.  Note: The wired do not run through the center of the ring, they run through the slot in the retaining ring.6.   Visually check that the wires are routed so that they will not catch on the cylinder cam.Fig. 2C
8          1-800-810-WIRE • www.sargentlock.com • A8078B Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.08/22/11 Profile Series v.N2 Mortise Lock  3  Mortise Lock Body DIP Switch Settings Fig. 3A4   Install LockbodyTo install the Lockbody: 1.  Feed the wires rst through the mortise pocket then feed the wires from the lockbody through the inside door prep for the mortise cutout (Fig. 4A).Note: Connectors and wires must be fed through the non-cylinder side. 2.  The wires from the lockbody exit the inside door prep through  the mortise cutout.3.  Loosely secure the lockbody in the door with two #12 x 1-1/4” wood screws or #12-24 x 1/2” machine screws.Note: Do not completely tighten at this time.(2) #12-24 x 1/2” Long Flat Head Screws for Metal Doors(2) #12 x 1-1/4” Long Flat Head Screws for Metal DoorsFig.  4AMortise  Connectors Inside of DoorDIP switchNOTE: The DIP switch RX settings located on  the rear of the mortise lockbody must be set prior  to lock installation. Failure to follow sticker directions will cause inaccurate RX activity to be reported to the access control panel.Set DIP switch for appropriate door application by sliding the DIP switch  to the side opposite the red surface of the locking slide.
08/22/111-800-810-WIRE • www.sargentlock.com • A8078B       9Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 Mortise Lock  5   Door OptionsA.  Fire Stop Plate (P/N 52-0033)   B.   Weather Conduit (P/N 52-2847)Install weather conduit (part number 52-2847) on NON Fire-Rated exterior doors only (Fig. 5B).1.  Carefully insert the weather conduit into the ribbon cable hole on the inside of the door.2.  Place the O-ring around the  weather conduit on the outside  and up against the door (Fig. 5B).   Fig.  5AOutside of Door(2) Self-Tapping #8 x 1/2” Screws for Wood and Metal DoorsFire  Stop PlateOutside of DoorFig.  5BFor exterior applications, use weatherseal gasket  between escutcheon and outside door surface. To apply weatherseal gasket: 1.  Carefully remove the backing from the gasket (Fig. 6A). 2.  Apply gasket to escutcheon:a.  Starting in one place, press the adhesive side of the gasket rmly against the escutcheon.b.  Work around the escutcheon, pressing the  sticky side of the gasket rmly against  the escutcheon edge.c.  The gasket should be aligned so that all edges of the escutcheon are covered.6   Install Gasket (for Exterior Doors) Fig.  6AFire-rated doors require a re stop plate on the outside of the door (Fig. 5A).1.  Drill (2) 1/8” x 1-1/4” deep holes in the door, if not already present.Refer to template for re-stop prep locations.2.  Attach with ap up and out using (2) #8 x 1/2”  self-tapping screws for wood and metal doors.
10          1-800-810-WIRE • www.sargentlock.com • A8078B Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.08/22/11 Profile Series v.N2 Mortise Lock  8   Install Lock1.  With outside lever horizontal, locate the outside escutcheon on the door,  while directing the mounting posts through the  door and lock body (Fig.8A).Make sure the lever spindle is properly  engaged in lock.2.  On the inside of the door, insert spindle  into the square hole of mortise lock.3.  Slide inside adapter and plate assembly  over spindle and loosely secure with  2 through-bolt screws (#8-32 x 5/8”).Note: For 82276 and 82278, loosely thread | cylinder through escutcheon and into the lock  body before tightening the lock case screws and  escutcheon through bolts.4.  Loosely install the optional cylinder, if present.5.  Fully tighten the lock case screws and  escutcheon through bolts.   1.  Attach escutcheons to the door after  the wires are connected.Note: The 43 cylinder may be used  with or without a gasket.2A. For fire rated doors:  Feed ribbon cable       with connector from outside of door through weatherseal        gasket and re stop plate (Fig. 7A).  Note: Install ribbon cable with        cable exiting down.2B. For non-fire rated doors:  Feed ribbon       cable with connector from outside of door through       weatherseal gasket (if used) and weather conduit.      Note: Install ribbon cable with cable exiting down.7   Install Outside EscutcheonFig.  6AOutside of DoorLock Case ScrewsInside of DoorFig.  8A
08/22/111-800-810-WIRE • www.sargentlock.com • A8078B       11Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 Mortise Lock  9  Inside Escutcheon ConnectionsBefore the controller is attached to the door:1.  Connect the cable from the mortise lock  to the bottom of the controller assembly (TB1).  Note: The red wire aligns with the Pin 1 indicator on the left of the PC board. There are two guide pins built into the PC board to aid in proper alignment.2.  Attach the reader assembly ribbon cable  into the controller assembly (TB2).Inside of DoorFig.  9AMortise ConnectorReader Ribbon Cable10  Install Inside Esutcheon 1.  Gently fold the excess ribbon cable into the ribbon cable hole and mortise and wires into the inside of lock body wire hole,  being careful not to pinch wires. 2.  Insert (2) #8-32 x 1-1/4” screws through inside  escutcheon and thread into outside escutcheon.Straighten escutcheons and tighten securely.Inside of DoorFig.  10A1Fig.  9A DetailPin 1 indicatorSmall alignment keyWide alignment keyRed wire (Pin 1) aligns on the left.TB1TB2
12          1-800-810-WIRE • www.sargentlock.com • A8078B Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.08/22/11 Profile Series v.N2 Mortise Lock  Inside of DoorFig.  11BFig.  11A12  Install and Secure CylinderFig.  12AOutside of Door11  Install Inside Lever1.  Slide lever handle onto spindle until fully  seated (Fig. 11A).2.  Tighten the set screw securely  with 1/8” hex wrench (Fig. 11B).1.  Slide cylinder through the spring and screw into lockbody, rotating the cylinder  clockwise (Fig. 12A). Cylinder should be ush with rosette/collar.Note: The 43 cylinder may be used when installing this product with or without a gasket.Note: SARGENT logo must be horizontal and on the top of the cylinder (Fig. 12B). 2.  Secure the cylinder by  tightening the cylinder clamp screw located  above the deadbolt using a #2 Phillips screwdriver (Fig. 12C).Using the key, test cylinder functions: •  82278 Function: Key retracts latch.•  82276 Function: Key retracts latch  and projects and retracts deadbolt.Fig.  12BCorrect               Incorrect#2 Phillips ScrewdriverCylinder  Clamp  ScrewFig.  12C
08/22/111-800-810-WIRE • www.sargentlock.com • A8078B       13Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 Mortise Lock  13  Attach Front PlateAttach front plate with (2) at head screws.Fig.  13AOutside of Door14  install or Replace Batteries1.  To install or replace batteries, rst remove the battery cover  (if necessary) using the provided security tool (Fig.14A). 2.  Unscrew the bottom screw of the battery keeper and remove  the battery keeper, being careful not to break the top tabs holding it in place (Fig.14B). 3.  Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly.4.  Replace battery keeper, being careful to engage  tabs on the top to hold it in place (Fig. 14B). 5.  Attach battery cover to inside escutcheon,  making sure to line up tabs with retaining slots  in battery cover (Fig. 14C). 6.  Secure with the security screw using tool. (Fig. 14A).Fig. 14BFig. 14CTabsRetaining Slots Inside of DoorFig. 14ASecurity Tool (01-029)Battery CoverSecurity ScrewNOTE: Ensure the tamper switch activator does not fall out of the cover during assembly. A tamper event mes-sage will be sent to the EAC panel if tamper is enabled.
14          1-800-810-WIRE • www.sargentlock.com • A8078B Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.08/22/11 Profile Series v.N2 Mortise Lock  For 82276- and 82278-function mortise locks with cylinders:1.  Insert key into cylinder and rotate.There should be no friction against lock case, wire harness or any other obstructions. (Refer to Section -6 Wiring if harness friction exists).2.  Check that the key retracts the latch: The key should rotate freely.3.  Throw the deadbolt:Check that the key retracts both the deadbolt and the latch.4.  Try the inside lever:Ensure it retracts latch and deadbolt (if provided).5.  Present a valid iCLASS or 125 kHz prox creden-tial to unlock outside lever and retract latch. Operational Check 7
08/22/111-800-810-WIRE • www.sargentlock.com • A8078B       15Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited. Profile Series v.N2 Mortise Lock  The lock has three LEDs that support an optical scheme with red, yellow and green.  The indication scheme is described by the gures below:Fig. Lock Normal operation LED indicationLock LED Indications8NOTE: When the lock mechanism is blocked (lock jammed) the knob must be turned to release it. The “Error in lock” indication is also shown instead of the POST ashes if the battery is not accepted as new after a power¬on¬reset.1  Lock Normal Operation LED indication2  Lock Maintenence LED Indication Some special LED indication schemes are used during lock maintenance actions:Enter configuration mode Five yellow flashes (.125 s each)Fig. Lock maintenance LED indication Card read  (congurable) Access granted,  EAC ofine or onlineAccess denied,   EAC online Access denied,  EAC ofine Lock mechanism is  blocked when closingError in lock,  maintenance required  Time to replace the battery   Battery reached end of life, lock disabledOne yellow ash (.25 second) One green ash (1 second)  One red ash (1 second)  Three red ashes (.5 s each) Continuous red ashes blocked when closing (.125 seconds every 1 second) Ten red ashes (.125 s each), maintenance required; repeated if lock can’t close Continuous yellow ashes (.25 seconds every 5 seconds) Continuous red ashes of life,  (.25 seconds every 5 seconds)
SARGENT Manufacturing100 Sargent DriveNew Haven, CT 06511 USA800-810-WIRE (9473) • www.sargentlock.comFounded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The company’s customer base includes commercial construction, institutional, and industrial markets.Copyright © 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.ASSA ABLOY is the global leader in door opening solutions, dedicated tosatisfying end-user needs for security, safety and convenience. A8078B - 08/113  Lock Self Test LED IndicationAfter replacing the battery, a Power On Self Test (POST) is performed. The result is indicated using a series of red and green LED ashes as is described by the gure below:One red, one green ash  (1 second each)   One red ash followed by 16 red or green ashes (.5 s each)Fig. Lock POST LED indicationThe rst ash is always red. If the POST fails, the color of the 16 trailing ashes indicate the status of each individual test as described by the following table: Blink Meaning if Red Code in Event Log2 Main board firmware corrupt 0x0001 3 Override list corrupt 0x00024 Production data corrupt 0x00045 Security data corrupt 0x00086 Configuration data corrupt 0x00107 Battery power low 0x00208 RFID reader circuit error 0x00409 Voltage regulator error 0x008010 Card detection circuit error 0x010011 Secure area communication error 0x020012 Secure area memory corrupt 0x040013 Secure area sensor or motor error 0x080014 Radio modem communication error 0x100015 Radio modem memory corrupt 0x200016 Radio modem configuration error 0x400017 Radio modem RF circuit error 0x8000NOTE: If the battery is not accepted as new after a power on reset, no POST is performed.                Instead, the 10 quick red ashes used to indicate Error in lock is shown.

Navigation menu