ASSALOY YRHCPZB0 Yale Real Living Electronic Zigbee Lock User Manual 12 0001 Exhibit Cover

ASSA ABLOY Inc. Yale Real Living Electronic Zigbee Lock 12 0001 Exhibit Cover

Manual - YRT210-ZB

    5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-YRHCPZB0 IC: 6982A-YRHCPZB0  FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210  ACS Project Number:  12-0001   Manufacturer: Assa Abloy Inc. Models: YRDZB, YRD210-ZB, YRD220-ZB, YRT210-ZB, YRT220-ZB     Manual – YRT210-ZB
For Technical Assistance call Yale at 1-800-810-WIRE (9473)NOTE TO INSTALLERFAILURE TO FOLLOW THESE INSTRUCTIONSCOULD RESULT IN DAMAGE TO THE PRODUCTAND VOID THE FACTORY WARRANTYAn ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev AThis document is available on our website in printed Spanish and French. Go to www.yalecommercial.com.  Click "Product Information  & Documentation" and then "Installation Instructions".Este documento está disponible en español en nuestra página de internet. Vaya a www.yalecommercial.com.  Presione "Información del Producto y Documentación" y luego "Instrucciones de Instalación".Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalecommercial.com. Cliquez sur le " ; Information sur le produit et Documentation" et puis " Installation Instructions".Yale Real Living™ Push Button LeverInstallation and Programming Instructions
2An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev AWarnings .........................................................................................................................2Return Lock to Factory Default ................................................................................3Introduction .....................................................................................................................3InstallationComponents and Tools .............................................................................................4Prepare Lock for Installation ................................................................................. 5-6Install Lock .......................................................................................................... 6-11ProgrammingProgramming Features-Menus-Keys-Definitions ............................................. 12-13Lock Operation ................................................................................................. 14-15Miscellaneous InformationHardware Troubleshooting ......................................................................................17 Programming Troubleshooting ...............................................................................18Installing the Network Module ...............................................................................19Change Lever Handing .................................................................................... 20-21Installing/Replacing Cylinder ................................................................................ 22Sample Pin Code Management Sheets ........................................................... 23-24TABLE OF CONTENTSWARNINGSFCC: FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee)Model(s): YRT210-ZW, YRT210-ZBThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to which the receiver           is connected.•  Consult the dealer or an experienced radio/TV technician for help.IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and security of this product. Misalignment can cause performance degradation and a lessening of security.Finish Care: This lockset is designed to provide the highest standard of product quality and perfor-mance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coat-ing and result in tarnishing.Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc. could void the user's authority to operate the equipment.
3An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A    Factory Default SettingsTo reset the lock to factory default, see the following:The following procedure returns the lock to its factory defaults by deleting all user codes (including the Master PIN code*) and returning all programming features to their original default settings (see below).  1. Remove the batteries and then remove the inside escutcheon           to access the reset button.2. The reset button (see image at right) is located above the            PCB cable connector. 3. Hold down the reset button for a minimum of 3 seconds and          then reinstall the batteries; once the batteries are properly              installed, release the reset button. All features, including adjustable settings** (see below) should     now be returned to factory default.Upon reset, Master Code Registration is the only option available and must be performed prior to any other programming of the lock.See "Operation" later in this manual for programming instructions.    Reset Lock to Factory DefaultReset ButtonInside EscutcheonSettings Factory DefaultMaster Code Registration requiredAuto Re-lock EnabledOne Touch Re-Lock EnabledAudio EnabledAuto Re-lock Time **30 SecondsWrong Code Entry Limit **5 TimesShutdown Time **60 Seconds**Adjustable only when using Network Module
4An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev AIndustry Canada:Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)Model(s): YRT210-ZW, YRT210-ZBThis Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:“This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie.Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device.Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.INTRODUCTIONThe Yale Real Living™ Stand-alone Push Button Lever Lock combines a robust lockset with a   contemporary electronic aesthetic.Users benefit from an interactive Push Button keypad that makes day-to-day access effortless for simple updates to user information in the event of staffing changes or security breaches.            Yale Real Living™ is engineered for quick and easy installation and fits in place of a standard lever lock door prep (ANSI/BHMA A156.115).If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network controller. That distance is influenced by objects between the lock and the controller and may be expanded depending on proximity to other RF network devices. Also, if the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.
5An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev ALock Installation #2 Phillips screw driver Allen wrench (3mm) - provided   Parts Illustrations    Tools NeededCOMPONENTS AND TOOLSINSTALLATIONOutsideEscutcheon Inside Escutcheon4 AA Alkaline BatteriesLatch boltStrike  Included in the box. . .Door Prep 2-1/8" (54mm) hole saw 1" (26mm) boring bit 7/64" (2.5mm) drill bit  Chisel & hammerNetwork Module (Optional)Latch BoltKeys(4) Inside Escutcheon Mounting Screws(2) Inside Mounting Plate Screws(2) Latch & (2) Strike Plate Mounting ScrewsCylinderAllen Wrench(2) Hex Set ScrewsOutside & Inside Lever HandlesInside Mounting Plate with Gasket (back of Inside Escutcheon)Battery CoverInstallation InstructionsTemplateLatch BoltStrike PlateInside Mounting Plate             (with gasket)Inside EscutcheonOutside Escutcheon(2) Screw Packs (see below)KeysCylinderBattery CoverAllen Wrench4 AA Alkaline Batteries
6An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev AINSTALL LOCK   Install LatchA.  Remove the latch (Fig. 1) and strike plate from the packaging.NOTE: Latch ships with backset in 2-3/8" position (Fig. 1).        Backset is the measurement from door edge to center               of 2-1/8" diameter hole (see template supplied with lock).If required, pull to extend to 2-3/4" backset position (Detail 1A).NOTE: Different holes are used for (2) through bolts depending on backset (see Detail 1A).Figure  1Detail 1A2-3/8" through bolt posts2-3/4" through bolt postsThe lock is packed representative of how it will install on the door.Before installing the lock on the door:B. Install latch bolt in door.  1. Attach with two (2) M4 x 25.4mm screws supplied.C.  Install strike on the door frame, using two (2) M4 x 25mm             screws supplied, making sure to allow for the latch to be            centered in the strike.NOTE: The latch bolt (and strike) can be installed in only one of two ways -              with the bevel (slope) of latch facing out or facing in while standing               outside of the door. If the door opens in, the bevel will face the outside; if the doors opens out, the bevel will face in. The strike plate is installed according to the orientation of the latch bolt. See Figures 1 & 2 for an example of a RH door that opens in.NOTE: Make sure door has been prepped according to specifications in template included              with lock.(4) M4 x 25.4mmFlat HeadCombination ScrewsNOTE: Both latch face and strike plate have adhesive-backed covers to                    prevent marring and should be removed upon installation.Figure  2
7An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev AOutside Escutcheon (with gasket)Outside of DoorFigure 1ADo not remove clip from Outside Escutcheon shank until correct handing has been determined and Outside Lever Handle is to be installed.(See page 9)1. From outside of door, position the outside escutcheon by first routing the cable      through 2-1/8" diameter hole and under the latch (Fig. 3A & B), then insert           posts* and tailpiece into the latch.    NOTE: Cable goes      under latch (Fig. 1A & 1B).  Outside of DoorFigure 1BInside of Door "Top" of Drive Tube       (marked WHITE)Tailpiece*Posts are inserted in holes according to backset adjustment. (Refer back to Detail 1A under "Install Lock") NOTE: The "tops" of both the square drive tube and the hub (in the shank) are marked to               indicate their orientation for proper installation (Figures A & B).   Install Outside Escutcheon
8An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A3.  Install outside escutcheon.     A. Position the outside escutcheon by routing the            cable through 2-1/8" diameter hole (Fig. 3A),               under the latch. NOTE: Cable goes    under latch (Fig. 3B).  Figure 3BInside of Door4.  Holding the outside escutcheon flush to the door,                    position the inside mounting plate by routing the       cable/connector through the mounting plate's 1/2"       rectangular hole below center hole and then route                   through left upper slot, then behind center rib (Fig. 4A).Figure 4A5.  Secure both assemblies using (2)  M4 x 25mm pan       head machine screws (Fig. 4A).      Ensure that outside escutcheon is vertically aligned.     Tighten securely with a #2 Phillips screwdriver.           Do not over-tighten.  Figure 3AOutside of DoorSquare Drive Tube  is marked (WHITE) to indicate "top""Top" of Drive Tube       (marked WHITE)     NOTE: The "tops" of both the square drive tube and the            tailpiece it contains are marked to indicate their                        proper orientation (Fig. 3A & 3B).      B. Ensure tailpiece is oriented in the horizontal position           (Fig. 3B) and insert tailpiece through center of latch            so that outside escutcheon is flush to the surface of                   the door.Tailpiece must be in horizontal positionRED mark indicates "top"
9An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A6.  Attach cable assembly to the inside escutcheon printed circuit board (PCB) by lining up       notches on top of cable connector to slots on PCB connector (Fig. 6A & 6B).      Press connector in firmly using thumbs until completely seated (properly seated position        indicated by arrows on PCB as in Fig. 6A and 6B). Figure 6ARoute cable as indicated - do not cover holes CAUTION: Use care when assembling to ensure that the cable lies against the back recessed area of the inside escutcheon (Fig. 6A). Position and bend cable, as shown in Fig. 6A to prevent binding when installing the escutcheon over the mounting plate.  7. Install inside escutcheon:     A. Ensure that thumb turn on inside escutcheon is positioned                   vertically (Fig. 7).      B. Install and secure inside escutcheon to inside mounting plate           using (4) M4 x 8mm [8-32 x 5/16"] pan head machine screws           through the inside escutcheon into the mounting plate. NOTE: Make sure cable does not obstruct path of the mounting                            screws and is not being pinched by any metal parts.VerticalFigure 6B
10An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev ABefore proceeding with the next step, determine that the handing of the lever is correct. Both outside and inside lever handles should always point toward the door hinges.    Determine Lever HandingNOTE: For correct lever handing, the              hex set screw for the outside               lever shank must be installed                as shown (Fig. 8B). Hex Set ScrewLH/LHRFigure  8BC. Install cylinder in outside lever as indicated (Fig. 8C).Note correct "swoop" of lever handle (Fig. 8C)CorrectFigure 8CRH/RHRIncorrectFigure 8AA. Once correct handing is determined, remove the       clip from the shank (Fig. 8A) that has held the              hub in its correct position. Do not rotate cam from its original position.B. Install hex set screw8. Attach outside lever handle to the outside escutcheon:Detail 8A1
11An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev AD.  Insert key in cylinder (outside lever handle); rotate key 90° clockwise (Fig. 8E). E.  Insert allen wrench (included) in set screw on side of shank (toward edge of                 door); turn clockwise to allow placement of lever handle over shank; do not overtighten.F.  Push lever handle/key/cylinder in until hole on handle aligns with set screw.  DEFFigure  8EHinge side of Door90°G.  Insert allen wrench and tighten set screw by turning counter-clockwise (Fig. 8F).H.  Turn key 90° counter-clockwise; pull to remove key and test operation of lever        handle, ensuring that the latch moves smoothly.H90°GFigure  8F
12An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A 9.  Attach inside lever handle: C.  Turn set screw counter-clockwise                            to tighten.10.  Insert four (4) AA alkaline batteries; the lock          will flash and beep several times..  11.  Note: Refer to programming instructions prior to            completion of this step.       Install battery cover and tighten Phillips         head screw.IMPORTANT:  Before installing the batteries, test the mechanical operation of lock                           by rotating the outside and inside lever handles. Also try using both the thumbturn and key. The movement of the latch should be smooth and unobstructed. If operation is not smooth, review the previous steps to ensure proper installation, while maintaining proper alignment of escutcheons.A. Rotate thumbturn counter-clockwise to horizontal position (Fig. 9A).B. Insert allen wrench (included) in set screw        on side of shank (toward edge of door);                    turn clockwise to allow placement of           inside lever handle over shank.Figure 9AFigure 9BFigure 9C
13An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev APROGRAMMINGPROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONSProgramming Features-Menus-Keys-Definitions ............................................. 12-13Operation .......................................................................................................... 14-15Network Module SlotAlkaline Batteries4 AA Type  Hex Screw     Battery Cover   Outside    Inside    Menu and Icons Used in This GuideClick the indicated number.     Enter Master PIN code* (4-8 digits in length).Press the Star key on the keypad to Enter or Accept entry.     Enter User PIN. Can be 4-8 digits in length.Press the Pound key on the keypad to enter Menu mode.User Number (1 - 25);  RF Controlled (1 - 250).~MUStatus IndicatorNumbersCylinder   Low Battery Warning1   Lockout Mode2     Return to previous step3    Status IndicatorsRED RED & BLUEBLUE*The Master Pin Code must be registered prior to any further programming of the lock.
14An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev ALockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user PIN code access. When attempting to enter a code while the unit is in Lockout, the Status Indicator flashes RED and BLUE; the keypad flashes as well.Low Battery: When battery power is low, the Status Indicator flashes RED. If battery power is completely lost, use the key override. Master PIN Code: The Master code is used for programming and for feature settings. NOTE: The Master Pin Code must be registered prior to programming the lock. The Master code will also operate the lock.Auto Re-Lock Time: After successful code entry and the unit unlocks, it will automati-cally re-lock after a default of thirty (30) seconds. Re-lock time is adjustable from five (5) to thirty (30) seconds.    One Touch Re-Lock: When the bolt is retracted, activating the keypad will extend the bolt       (during Auto Re-Lock duration or when Auto Re-Lock is disabled). Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow operation after the wrong code entry limit has been met. When the unit is in Shutdown, the Status Indicator flashes RED and BLUE; the keypad flashes as well.Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone playback for use in quiet areas. Audio mode is enabled or disabled through feature pro-gramming by the Master code.Status LED: Located on inside escutcheon. User PIN Code: The User code operates the lock. Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes.Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is adjustable from three (3) to ten (10) times through feature settings (up to 5 times with no RF network enabled - default is 5; 10 with RF network enabled).     Definitions    Factory Default Settings*Adjustable with Network ModuleSettings Factory DefaultMaster Code Registration requiredAuto Re-lock EnabledOne Touch Re-Lock EnabledAudio EnabledAuto Re-lock Time **30 SecondsWrong Code Entry Limit **5 TimesShutdown Time **60 Seconds
15An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A1Press the   key to enter Master Code Registration.   1Enter a 4-8 digit Master PIN code      followed by the   key.    2   1.  Press the   key to enter Master Code Registration. 2.  Enter a 4-8 digit Master PIN code followed by the   key.    Register Master Code Before Programming*User Codes can only be programmed through the Master Code*.1. Enter the 4-8 digit Master PIN code followed by the   key. 2. Enter   followed by the   key. 3. Enter the User number to be registered (1-25) followed by the   key. 4. Enter a 4-8 digit PIN code for the User number followed by the   key.    User Pin Code RegistrationNote: When registering User codes, the code must be entered within 20 seconds. If time expires, no codes are registered and the process must be re-started.    PIN code structureMaximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes.*Master PIN Code must be registered prior to programming the lock.OPERATION
16An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev AEnable  Disable        Feature Programming Through Menu Mode Using Master PIN code*  *The Master PIN code must be registered prior to programming of the lock.1. Enter the 4-8 digit Master PIN code followed by the   key. 2. Enter digit corresponding to the function to be performed followed by the   key. Note: If the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit. 12Master PIN RegistrationMMUser Number (UN) 1~25: without network module 1~250: with network module   User PIN RegistrationCompleteUCompleteFor quiet areas, select Disable (3) in Audio Mode.RegisterDelete   Advanced Lock SettingsAudio ModeN/A All Code Lockout**Network Module Setting RegisterEnableEnableDisableDeleteDisable**This function appears only with RF network module installed.Auto Re-lock Setting Enable  Disable   Inside Escutcheon LEDOne Touch Locking Setting Enable  Disable   Note: If the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.
17An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A   Open Door with PIN Code   1  Enter PIN code.    2Complete the code entry  by pressing the   key.Unlock.   3
18An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev ACycle the lock in both the locked and the unlocked positions. If problems are found: TROUBLESHOOTING    Hardware TroubleshootingSymptom Suggested ActionDoor is binding a. Check that door and frame are properly aligned and door is free swinging.b. Check hinges: They should not be loose or have excessive wear on knuckles. Latch bolt will not deadlock a. Check for sufficient clearance of the latch bolt within the strike-side jamb. Correct this by     increasing the depth of the pocket for the latch bolt.b. Check for misalignment of latch bolt and/or strike which may be preventing latch bolt from     properly entering the strike. With the door open, extend and retract the latch bolt; if it is     smooth, check the strike alignment. Latch bolt does not extend or retract smoothly   a.  Latch bolt and strike are misaligned, see above.b. Check the backset of door relative to adjustments already made to latch bolt.c. Verify proper door preparation and re-bore holes that are too small or misaligned.d. Verify keypad cable/connector is routed under the latch bolt (see Fig. A).e. Verify latch bolt is installed with correct side up (Fig. A).MISCELLANEOUSHardware Troubleshooting ......................................................................................17 Programming Troubleshooting ...............................................................................18Installing the Network Module  ...............................................................................19Change Lever Handing .................................................................................... 20-21 Replace/Install Cylinder  .........................................................................................22Sample Pin Code Management Sheets ........................................................... 23-24Inside of DoorFigure A
19An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A    Programming Troubleshooting*  When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface; it is                recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).** Network module units onlySymptom Suggested ActionLock does not respond – door is open and accessible.•  Press each keypad button to see if they respond when pressed.•  Check batteries are installed and oriented correctly (polarity) in the battery case.•  Check batteries are in good condition; replace batteries* if discharged.•  Check to see if cable is fully connected and not pinched.Lock does not respond – door is locked and inaccessible. •  Batteries may be completely discharged.•  Use mechanical key to gain entry and replace batteries*.Unit chimes to indicate code accep-tance, but the door will not open.•  Check to see if there is another locking device on the door.•  Check the door gaps for any foreign objects between door and frame.•  Check that the cable is firmly connected to the PC board.Unit operates to allow access, but will not automatically re-lock. •  Check to see if Auto Re-lock Mode is enabled. •  Disable Auto Re-lock Mode to lock the door (automatically).•  If low battery indicator is lit (see below), change batteries*.PIN codes will not register. •  PIN codes must consist of 4 to 8 digits to register.•  The same PIN code cannot be used for multiple users. •  Registration/management of PIN codes is set by the authority of the Master Code.•  Contact the Master user•  User codes must be entered within 20 seconds or the process will have to be restarted.•  The star  (*) or pound   (#) cannot be used as part of the PIN code.Upon entering a PIN code and press-ing the star (*) key, the lock gives a series of beeps, flashes red and blue LEDs seven times, and does not unlock.  •  Lockout Mode is enabled.•  Only the Master can enable/disable Lockout Mode.•  Contact the Master user.Upon entering a PIN code and press-ing the (*) key, there are different tones.•  Check to see if the lock is set to Lockout Mode.•  Setting/managing Lockout Mode is done through Master Code only. Contact the Master user.The unit operates, but it makes  no sound.•  Enable Audio Mode.The unit displays intermittent RED flashes.•  This is the Low Battery indicator alerting that it is time to replace the batteries. Replace all four (4) batteries* with new AA Alkaline batteries.Upon entering a PIN code and press-ing the star (*) key, the unit responds  with a series of beeps and the keypad flashes three times.•  The digits entered were incorrect or incomplete. Re-enter the correct code followed by the star   key.
20An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev AIMPORTANT: The batteries must be removed prior to removing and/or inserting the network module:•  Remove batteries•  Remove and/or insert network module•  Reinstall batteries   Installing the Network ModuleUse Feature Programming step 7 (page 15) for enrollment of the Network Module.
21An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A   How to Change Handing of Lever (Reverse Levers)1.   Remove the outside lever handle:A.  Insert key in cylinder (outside lever handle); rotate key 90° clockwise. B.  Insert allen wrench (included) in set screw on side of lever (toward edge of          door); turn clockwise to loosen lever handle.C.  Pull to remove lever handle/key/cylinder.   A90°90°CB
22An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A2. Remove the inside lever handle:A. Insert allen wrench (included) in set screw on side of lever       (towards edge of door); turn clockwise to loosen handle.B.  Pull to remove lever handle.   AA. Remove and switch handles (inside to outside, outside to inside).B. Remove cylinder from outside lever handle.C. Insert cylinder in "new" outside lever (Fig. 3A).D. Push handle in allowing holes for set screw to align.E. Insert set screw and tighten lever handle by turning set screw counter-clockwise.3. Change the lever handing:IncorrectNOTE:  "Swoop" of lever handle must be oriented in upward direction as shown in  Fig. 3ACorrectFigure 3ABFigure 3B
23An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A1.   Remove cylinder:A. Repeat previous steps for removing the outside lever handle.B. Remove cylinder.   How to Replace or Install Cylinder2.   Install new cylinder:      A. Insert cylinder in "new" outside lever.     B. Push handle in allowing holes for set screw to align.         C. Insert set screw and tighten by turning set screw counter-clockwise.      D. Verify that new cylinder fits and rotates freely.     E. Test operation of the new cylinder/key.
24An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev APIN CODE MANAGEMENT SAMPLE SHEETSPIN Code Management  (No Network Module - Up to 25 Users)Location:                                                        Door Number:  User User Name User # PIN CodeUser Type User Name User  # PIN CodeMaster User 13User 01  User 14User 02 User 15User 03 User 16User 04 User 17User 05 User 18User 06 User 19User 07 User 20User 08 User 21User 09 User 22User 10 User 23User 11 User 24User 12 User 25
25An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev APIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entriesUser Type User Name User  # PIN Code User User Name User # PIN CodeMaster User ___ User ___ User ___ User ___  User ___  User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___
ONLINE LITERATURE AND TEMPLATESFor the latest information on Yale products visit our website at www.yalelocks.com. Click on the “Literature” button to find the most up-to-date catalogs, parts manuals, templates, specifica-tions and installation instructions.Yale Locks & Hardware100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.comYale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Yale Real Living™ is a trademark of Copyright © 2012, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without express written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited.YALE, with its unique global reach and range of products, is the world’s favorite lock — the preferred solution for securing your home, family and personal belongings.ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.An ASSA ABLOY Group brandP/N AYRT-210-INST-FUL Rev A