ASSALOY YRHCPZW0 Yale Real Living Electronic Zwave Lock User Manual 12 0002 Exhibit Cover

ASSA ABLOY Inc. Yale Real Living Electronic Zwave Lock 12 0002 Exhibit Cover

Manual - YRD210-ZW

Download: ASSALOY YRHCPZW0 Yale Real Living Electronic Zwave Lock User Manual 12 0002   Exhibit Cover
Mirror Download [FCC.gov]ASSALOY YRHCPZW0 Yale Real Living Electronic Zwave Lock User Manual 12 0002   Exhibit Cover
Document ID1641738
Application IDhwxrwbuvx9WRa7qdctdcMw==
Document DescriptionManual - YRD210-ZW
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize299.63kB (3745414 bits)
Date Submitted2012-02-22 00:00:00
Date Available2012-02-22 00:00:00
Creation Date2012-02-17 13:51:17
Producing SoftwareAdobe Acrobat Pro 9.0.0
Document Lastmod2012-02-17 13:51:17
Document TitleMicrosoft Word - 12-0002 - Exhibit Cover.doc
Document CreatorAdobe Acrobat Pro 9.0.0
Document Author: courtney.merrick

Certification Exhibit
FCC ID: U4A-YRHZPZW0
IC: 6982A-YRHZPZW0
FCC Rule Part: 15.249
IC Radio Standards Specification: RSS-210
ACS Project Number: 12-0002
Manufacturer: Assa Abloy Inc.
Models: YRD220-ZW, YRD210-ZW, YRT210-ZW, YRT220-ZW
Manual – YRD210-ZW
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Yale Real Living™ Push Button Deadbolt
Installation and Programming Instructions
NOTE TO INSTALLER
FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN DAMAGE TO THE PRODUCT
AND VOID THE FACTORY WARRANTY
For Technical Assistance call Yale at 1-800-810-WIRE (9473)
This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com.
Click “Product Information & Documentation” and then “Installation Instructions”.
Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com.
Presione “Información del Producto y Documentación” y luego “Instrucciones de Instalación”.
Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com.
Cliquez sur le “ ; Information sur le produit et Documentation” et puis “Installation Instructions”.
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
TABLE OF CONTENTS
Warnings...................................................................................................................... 2-4
Reset Lock to Factory Default...................................................................................3
Introduction......................................................................................................................4
Installation
Components and Tools..............................................................................................5
Prepare Lock for Installation......................................................................................6
Install Lock............................................................................................................. 7-8
Programming
Programming Features-Menus-Keys-Definitions................................................ 9-10
Lock Operation.................................................................................................. 11-12
Miscellaneous Information
Hardware Troubleshooting.......................................................................................13
Programming Troubleshooting................................................................................14
Installing the Network Module.................................................................................15
Replace/Install Cylinder...........................................................................................16
Sample Pin Code Management Sheets............................................................ 17-18
WARNINGS
Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc.
could void the user's authority to operate the equipment.
IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and
security of this product. Misalignment can cause performance degradation and a lessening of
security.
Finish Care: This lockset is designed to provide the highest standard of product quality and
performance. Care should be taken to ensure a long-lasting finish. When cleaning is required
use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes
could damage the coating and result in tarnishing.
FCC:
FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee)
Model(s): YRD210-ZW, YRD210-ZB
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful Interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
To Ensure Proper Lock Handing and for an explanation
of how to determine your lock handing, please read this
important note.
IMPORTANT: Do not install batteries until the lock is completely installed on door.
For your convenience, the Yale Real Living lock will automatically determine
whether it will function as a right or left-handed lock. (The "hand" or "handing"
of the lock, is determined by the side of the entry door that the hinges are on
when standing outside the door)
NOTE: The bolt must be in a retracted (unlocked) position when
installing the lockset and before batteries are installed.
When the batteries are properly inserted for the first time, the lock will attempt
to determine its handing - whether the lock is installed on the door or not. If the
lock is not completely installed on the door, it could hand itself incorrectly.
Should this occur, the lock must be installed on the door and then reset to its
factory defaults, allowing the lock to "hand" itself correctly.
To reset the lock to factory default, see the following:
Reset Lock to Factory Default
The following procedure clears the automatic handing of the
lock and returns the lock to programming default - deleting
all user codes and setting the Master PIN code* back to the
default ("12345678").
Reset Button
Cable
1. Remove the batteries and then remove the inside escutcheon
to access the reset button.
2. The reset button (see image at right) is located above the
PCB cable connector.
3. Hold down the reset button for a minimum of 3 seconds and
then reinstall the batteries; once the batteries are properly
installed, release the reset button.
Inside Escutcheon
4. Reassemble the lock by reversing the same steps on page 6.
All features should now be returned to factory default.
*The default Master PIN code must be changed prior to programming of the lock.
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
Industry Canada:
Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)
Model(s): YRD210-ZW, YRD210-ZB
This Class B digital apparatus meets all requirements of the Canadian Interference Causing
Equipment Regulations. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne
causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce
dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle
interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:
“This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm between
the radiator and your body. This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.”
Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its gain should be
so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne
d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour
réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies
de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire
pour une communication réussie.
Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s).
Operation is subject to the following two conditions: 1) this device may not cause interference, and 2)
this device must accept any interference, including interference that may cause undesired operation of
the device.
Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son
fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des
interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent
causer un mauvais fonctionnement du dispositif.
INTRODUCTION
The Yale Real Living™ Stand-alone Push Button Deadbolt Lock combines a robust lockset with a
contemporary electronic aesthetic.
Users benefit from a push button keypad that makes day-to-day access effortless for simple updates
to user information in the event of staffing changes or security breaches. Yale Real Living™ is engineered for quick and easy installation and fits in place of a standard deadbolt lock door prep (ANSI/
BHMA A156.115).
If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network
controller. That distance is influenced by objects between the lock and the controller and may be
expanded depending on proximity to other RF network devices. Also, if the lock is connected to a
network controller, it is recommended that it is programmed through the centralized user interface
(PC or hand-held device) to ensure communication between the lock and the controller unit.
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
INSTALLATION
COMPONENTS AND TOOLS
Included in the box. . .
Quick Start Guide
Inside Escutcheon
Bolt
Installation Instructions
Inside Mounting Plate
Strike Plate
Door Marker
Battery Cover
Screw Pack
Outside Escutcheon
4 AA Alkaline Batteries
Keys
Parts Illustrations
Bolt
Battery Cover
Outside
Escutcheon
(2) Through
bolts
Inside
Escutcheon
4 AA Alkaline
Batteries
Inside
Mounting
Plate
(3) Inside Escutcheon
Mounting screws
Keys
Strike Plate
(4) Bolt & Strike Plate
Mounting Screws
Network Module
(Optional)
Tools Needed
Door Prep
ƒƒ 2-1/8" (54mm) hole saw
Lock Installation
ƒƒ #2 Phillips screwdriver
ƒƒ 1" (26mm) boring bit
ƒƒ 7/64" (2.5mm) drill bit
ƒƒ Chisel & hammer
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
PREPARE LOCK FOR INSTALLATION
Unpack the Lock
The lock is packed representative of how it will install on
the door.
Before installing the lock on the door:
A. Inside escutcheon
1. Loosen the screw (Phillips #2) holding the battery
cover. (The screw remains attached to battery
cover)
2. Slide the battery cover up and out (note the two tabs
at bottom of battery cover).
3. Remove the inside mounting plate (with gasket) from
the back (door side) of the inside escutcheon.
Battery Cover
Inside Escutcheon
a. Ensure that gasket
on Inside Mounting
Plate is properly
fitted. Note the
positioning of the
gasket's five rubber
nubs (Figure 3A) .
Inside Escutcheon & Mounting Plate
(with gasket)
Figure 3A
B. Bolt
Note: Bolt ships with backset in 2-3/8" position. If required, press small black button on
underside of bolt and pull to extend to 2-3/4"
backset position.
Detail 3B1
Figure 3B
C. The outside escutcheon (with gasket) remains assembled.
Outside Escutcheon
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
INSTALL LOCK
1. Install bolt in door.
NOTE: The bolt must be in a retracted (unlocked) position
when installing the lockset.
Attach with (2) M4 x 25.4mm [8-32 x 1"] screws supplied.
(2) M4 x 25.4mm
[8-32 x 1"]
Flat Head
Combination Screws
2. Install strike on the door frame, making sure to allow
for the bolt to be centered in the strike.
(2) M4 x 25.4mm
[8-32 x 1"]
Flat Head
Combination Screws
3. Install outside escutcheon.
As you position the outside escutcheon, route the
cable through 2-1/8" diameter hole (Figure 3A).
NOTE: Cable goes under bolt (see Fig. 3B).
Figure 3A
4. Holding the outside escutcheon flush to the door,
position the inside mounting plate by first routing
the cable and connector through the mounting 		
plate's 1/2" hole (Fig. 4A) and then inserting the
mounting plate “tongue“ into the bottom slot of the
outside escutcheon (Fig. 4B).
Figure 3B
“Tongue”
Figure 4A
Figure 4B
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
5. Secure both assemblies using (2) M6 x 59.5mm
pan head machine screws, making sure that
outside escutcheon is vertically aligned.
Hand-tighten until snug. Do not over-tighten.
CAUTION:
Use care when assembling to ensure that
the cable lies against the back recessed
area of the inside escutcheon (Fig. 6A).
Position and bend cable, using the harness
clip as shown in Fig. 6A to prevent binding
when installing the escutcheon over the
mounting plate.
Route cable
as indicated do not cover
hole
6. Attach cable assembly to the inside escutcheon
PC board by lining up notches on top of cable
connector to slots on PCB connector (Fig. 6B).
Note that connector should be pressed in firmly using thumbs until completely seated (proper position
indicated by arrows on PCB as in Fig. 6A & 6B ) .
Figure 6A
Figure 6B
7. Install inside escutcheon on inside mounting
plate. Note the horizontal orientation of the tailpiece (Fig. 7A) as you insert the inside escutcheon
(thumb turn should be vertical).
8. Install and secure using (3) M4 x 8mm [8-32 x 5/16"]
pan head screws through the inside escutcheon into
the mounting plate.
Figure 7A
IMPORTANT: Before installing the batteries, test
the mechanical operation of the lock by using
both thumb turn and the key. The movement of the
bolt should be smooth and unobstructed. If
operation is not smooth, review the previous steps
to ensure proper installation.
NOTE: The bolt must be in a retracted (unlocked) position
prior to installing the batteries.
9. Insert four (4) AA alkaline batteries. The lock responds
with a series of beeps, a red/blue flash and a quick flash
of all keypad LEDs. When activating the lock for the
first time, the lock will adjust for proper handing.
Note: Refer to programming instructions prior to completion of
step 10.
10. Install battery cover and tighten Phillips head screw.
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
PROGRAMMING
Programming Features-Menus-Keys-Definitions................................................ 8-10
Operation........................................................................................................... 11-13
PROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONS
Outside
Inside
Phillips Screw
Status Indicator
Battery Cover
Network Module Slot
Numbers
Alkaline Batteries
4 AA Type
Cylinder
Status Indicator
Thumb Turn
Privacy Mode Button
Menu and Icons Used in This Guide
Click the indicated number.
Enter Master PIN code (4-8 digits in
length).
(Factory default: 12345678)
Press the Star key on the keypad to Enter
or Accept entry.
Enter User PIN. Can be 4-8 digits in
length.
Press the Pound key on the keypad to
enter Menu mode.
User Number (1 - 25);
RF Controlled (1 - 250).
Status Indicators
Low Battery Warning
RED
Lock-out Mode
RED &
BLUE
Return to previous step
BLUE
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
Definitions
Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all
user PIN code access. When attempting to enter a code while the unit is in Lockout, the
Status Indicator flashes RED and BLUE; the keypad flashes as well.
Low Battery: When battery power is low, the Status Indicator flashes RED. If battery
power is completely lost, use the key override.
Master PIN Code: The Master code is used for programming and for feature settings.
NOTE: The default Master Pin Code must be changed prior to programming the
lock. The Master code will also operate the lock.
Privacy Mode: This button located under the thumb turn on the inside escutcheon, activates and deactivates the keypad and is indicated by a BLUE flash every ten (10) seconds. It is also overridden by mechanically operating the thumb turn or key.
Auto Re-lock Time: After successful code entry and the unit unlocks, it will automatically
re-lock after a default of thirty (30) seconds. Re-lock time is adjustable from five (5) to
thirty (30) seconds.
One Touch Re-Lock: When the bolt is retracted, activating the keypad will extend the bolt
(during Auto Re-Lock duration or when Auto Re-Lock is disabled).
Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow
operation after the wrong code entry limit has been met. When the unit is in Shutdown,
the Status Indicator flashes RED and BLUE; the keypad flashes as well.
Silent Mode: Choosing Silent (3) in Audio mode shuts off the code confirmation tone
playback for use in quiet areas. Audio mode is enabled or disabled through feature programming by the Master code.
Status LED: Located on inside escutcheon.
User PIN Code: The User code operates the lock. Maximum number of user codes is
250 with Network Module; without Network Module, maximum is 25 user codes.
Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering
a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is
adjustable from three (3) to ten (10) times through feature settings (up to 5 times with no
RF network enabled - default is 5; 10 with RF network enabled).
Factory Defaults
Settings
Factory Defaults
Master Code
12345678
Auto Re-lock
Enabled
Audio
Enabled
Re-lock Time
*30 Seconds
Wrong Code Entry Limit
*5 Times
Shutdown Time
*60 Seconds
*Adjustable with Network Module
10
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
Lock Operation
Change Default Master Code Before Programming*
1. Enter the 8-digit default Master PIN code (12345678) followed by the
2. Enter “1” followed by the
key.
key.
3. Enter new 4-8 digit Master PIN code followed by the
key.
*Default Master PIN Code must be changed prior to programming the lock.
11
Enter current Master PIN code,
followed by the
key.
Enter '1' to change Master PIN code,
followed by the
key.
Enter the new Master PIN code (4~8
digits), followed by the
key.
PIN code structure
Maximum number of user codes is 250 with Network Module; without Network Module,
maximum is 25 user codes.
Set Up User Codes
User Codes can only be programmed through the Master Code.
key.
1. Enter the 4-8 digit Master PIN code followed by the
key.
2. Enter “2“ followed by the
3. Enter the User number to be registered (1-25) followed by the
4. Enter a 4-8 digit PIN code for the User number followed by the
key.
key.
Note: When registering User codes, the code must be entered with in 20 seconds.
If time expires, no codes are registered and the process must be re-started.
Privacy Mode vs. Lockout Mode
ƒƒ Lockout is a Menu feature that restricts Pin code access (except Master).
ƒƒ Privacy mode is set by pressing and holding the button (found below thumb turn) for a
duration of four beeps. This deactivates the keypad, and because it is set from the inside,
provides a secure lock for the convenience of the occupant(s).
11
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
Open Door with PIN Code
Enter PIN code.
Complete the code entry
key.
by pressing the
Unlock.
Feature Programming Through Menu Mode Using Master Code*
1. Enter the 4-8 digit Master PIN code followed by the
key.
2. Enter digit corresponding to the function to be performed followed by the
key.
Note: If the lock is connected to a network controller, it is recommended that it is
programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.
User Number (UN)
ƒƒ 1~25: without network module
Master PIN Setting
ƒƒ 1~250: with network module
User PIN Registration
User PIN Deletion
Auto Re-lock
Complete
Complete
Enable
Disable
Audio Mode
Enable
For quiet areas, select Disable (3)
in Audio Mode.
Disable
All Code Lock-out
Enable
Disable
7 *Network Module Setting
*This function appears
only with network module
installed
Register
Delete
CAUTION: When joining a network your controller may or may not
be aware of any previously saved user codes stored in the lock. It is
recommended that all user codes be deleted from the lock prior to
joining a network.
12
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
MISCELLANEOUS
Hardware Troubleshooting.......................................................................................13
Programming Troubleshooting................................................................................14
Installing the Network Module.................................................................................15
How to Replace/Install Cylinder..............................................................................16
Sample Pin Code Management Sheets............................................................ 17-18
TROUBLESHOOTING
Hardware Troubleshooting
Cycle the lock in both the locked and the unlocked positions. If problems are found:
Symptom
Door is binding
Suggested Action
a. Check that door and frame are properly aligned and door is free swinging.
b. Check hinges: They should not be loose or have excessive wear on knuckles.
Bolt will not deadlock
a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing
the depth of the pocket for the bolt.
b. Check for misalignment of bolt and/or strike which may be preventing bolt from properly
entering the strike. With the door open, extend and retract the bolt; if it is smooth, check the
strike alignment.
Bolt does not extend or retract smoothly
a. Bolt and strike are misaligned, see above.
b. Check the backset of door relative to adjustments already made to bolt.
c. Verify proper door preparation and re-bore holes that are too small or misaligned.
d. Verify keypad cable/connector is routed under the bolt (see Fig. A).
e. Verify bolt is installed correct side up (Fig. A).
Figure A
Yale Real Living™ locks are automatically handed. On startup, hold down the reset button
and wait while the lock tests bolt operation. The default Master Pin Code must be changed
before any other programming.
13
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
Programming Troubleshooting
Symptom
Suggested Action
Lock does not respond – door is
open and accessible.
•
•
•
•
Press each keypad button to see if they respond when pressed.
Check batteries are installed and oriented correctly (polarity) in the battery case.
Check batteries are in good condition; replace batteries* if discharged.
Check to see if cable is fully connected and not pinched.
Lock does not respond – door is
locked and inaccessible.
•
•
Lock may be in Privacy mode (set from inside room). Mechanical key will grant access.
Batteries may be completely discharged.
•
Use mechanical key to gain entry and replace batteries*.
Unit chimes to indicate code acceptance, but the door will not open.
•
•
•
Check to see if there is another locking device on the door.
Check the door gaps for any foreign objects between door and frame.
Check that the cable is firmly connected to the PC board.
Unit operates to allow access, but will
not automatically re-lock.
•
Check to see if Auto Re-lock Mode is enabled.
•
Disable Auto Re-lock Mode to lock the door (automatically).
If low battery indicator is lit (see below), change batteries*.
•
PIN codes will not register.
•
•
•
•
•
PIN codes must consist of 4 to 8 digits to register.
The same PIN code cannot be used for multiple users.
Registration/management of PIN codes is set by the authority of the Master Code.
•
Contact the Master user
User codes must be entered within 20 seconds or the process will have to be restarted.
The star
(*) or pound
(#) cannot be used as part of the PIN code.
Upon entering a PIN code and pressing the star (*) key, the lock gives
a series of beeps, flashes red and
blue LEDs seven times, and does not
unlock.
•
•
Lockout Mode is enabled.
Only the Master can enable/disable Lockout Mode.
•
Contact the Master user.
Upon entering a PIN code and pressing the (*) key, there are different
tones.
•
•
Check to see if the lock is set to Lockout Mode.
Setting/managing Lockout Mode is done through Master Code only. Contact the Master
user.
The unit operates, but it makes
no sound.
•
Enable Audio Mode.
The unit displays intermittent RED
flashes.
•
This is the Low Battery indicator alerting that it is time to replace the batteries. Replace
all four (4) batteries* with new AA Alkaline batteries.
Upon entering a PIN code and pressing the star (*) key, the unit responds
with a series of beeps and the keypad
flashes three times.
•
The digits entered were incorrect or incomplete. Re-enter the correct code followed by
the star
key.
* When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface (UI); it
is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).
** Network Module locks only
14
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
Installing the Network Module
IMPORTANT: The batteries must be removed prior to removing and/or inserting the
network module:
• Remove batteries
• Remove and/or insert network module
• Reinstall batteries
Use feature programming step 7 (page 13) for enrollment of the
Network Module.
15
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
How to Replace or Install Cylinder
1. Remove cylinder:
A. Remove outside escutcheon from door.
B. Remove rubber gasket.
C. Remove two screws holding plastic guide
in place.
D. Remove plastic guide.
E. Remove screw with washer holding cylinder in
place (visible after plastic guide is removed).
F. Remove cylinder by pulling towards the
door side of escutcheon.
Before installing cylinder, please be sure you have
correct length tailpiece.
2. Install new cylinder:
A. Reverse previous steps for removing cylinder.
Cylinder tailpiece information:
1-3/8"* to 2" thick doors, L = 3-1/2" (88.8mm)
2" to 2-1/4" thick doors, L = 3-3/4" (95.3mm)
Tailpiece
*Requires addition of Thin Door Kit.
T = .098" (2.5mm)
W = .2" (5.2mm)
16
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
PIN CODE MANAGEMENT SAMPLE SHEETS
PIN Code Management (No Network Module - Up to 25 Users)
Location:
User Type
Door Number:
User Name
User #
User
User Name
User #
PIN Code
PIN Code
Master
User 13
User 1
User 14
User 2
User 15
User 3
User 16
User 4
User 17
User 5
User 18
User 6
User 19
User 7
User 20
User 8
User 21
User 9
User 22
User 10
User 23
User 11
User 24
User 12
User 25
17
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries
User Type
User Name
User #
PIN Code
User
Master
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User ___
User Name
User #
PIN Code
18
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand
ONLINE LITERATURE AND TEMPLATES
For the latest information on Yale products visit our website at
www.yalelocks.com. Click on the “Literature” button to find the
most up-to-date catalogs, parts manuals, templates, specifications and installation instructions.
Yale Locks & Hardware
100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company.
Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Yale Real Living™ is a trademark of
Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2011, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without express
written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited.
YALE, with its unique global reach and range of products, is the world’s favorite lock — the preferred solution for securing your home, family
and personal belongings.
ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : courtney.merrick
Create Date                     : 2012:02:17 13:51:17-05:00
Modify Date                     : 2012:02:17 13:51:17-05:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2012:02:17 13:51:17-05:00
Creator Tool                    : Adobe Acrobat Pro 9.0.0
Format                          : application/pdf
Title                           : Microsoft Word - 12-0002 - Exhibit Cover.doc
Creator                         : courtney.merrick
Document ID                     : uuid:d5299165-6a95-4852-8e79-66f60ec67a3a
Instance ID                     : uuid:d7fe6a5c-de73-4ee1-8349-6453db68918f
Producer                        : Adobe Acrobat Pro 9.0.0
Page Count                      : 20
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4A-YRHCPZW0

Navigation menu