ASUSTeK Computer BAPAC1750 Business Dual-band Wireless-AC Access Point User Manual Users manual

ASUSTeK Computer Inc Business Dual-band Wireless-AC Access Point Users manual

Users manual.pdf

Download: ASUSTeK Computer BAPAC1750 Business Dual-band Wireless-AC Access Point User Manual Users manual
Mirror Download [FCC.gov]ASUSTeK Computer BAPAC1750 Business Dual-band Wireless-AC Access Point User Manual Users manual
Document ID3275648
Application IDZVwWJ5lMfJ8RdAvI9vWbfw==
Document DescriptionUsers manual.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize115.17kB (1439677 bits)
Date Submitted2017-02-03 00:00:00
Date Available2017-08-02 00:00:00
Creation Date2016-11-01 17:10:29
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2017-01-06 17:10:49
Document TitleUsers manual.pdf
Document CreatorAdobe InDesign CS6 (Windows)

Hardware features
Quick Start Guide
1 x BAP-AC1750
1 x BAP mounting bracket
1 x DC adapter (12V/2A)
1 x Quick Start Guide
1 x VIP card
Mounting accessories
4 x Truss head machine screws (Φ4mm)
4 x Jam nuts
4 x Flat washers
Extra accessories
4 x Round head drywall screw (Φ3mm)
4 x M.6 plastic anchors (Φ6.5mm)
NOTE:		 If any of the items is damaged or missing, contact ASUS for technical inquiries and
support.
Mounting to the ceiling
You can mount your BAP-AC1750 to the ceiling either on the ceiling tile rail (T-bar) or
on the ceiling tile.
On the T-bar rail
1. On the installed T-bar rail on the
ceiling, install the bundled bracket
through the T-bar holder. The AP
weight is sustained by the clamp.
NOTE:		 The bundled bracket supports the
T-bar width up to 24mm.
2. Install your BAP-AC1750 into the
bracket.
Mounting your BAP-AC1750 directly to the wall
Requirements
1. Drill two 6.5mm holes on the wall with a distance of 281mm betweeen them.
2. Place two 6.5mm M6 plastic anchors in the two holes.
3. Tighten two 3mm round head drywall screws into the two M6 plastic anchors in
the holes.
4. Hang your BAP-AC1750 into the two screws on the wall.
• CAT5e network cable or better
• Drill and drill bit (6.5mm for wall‐mounting or 4mm for ceiling‐mounting)
• Optional: Drywall or keyhole saw (to cut 25mm hole for the Ethernet cable feed)
BAP-AC1750
Package contents
Hardware installation
Guidelines
1.
Ethernet LED
Solid green: Ethernet cable is connected, but no data transmission.
Quick flashing green: Ethernet cable is connected, and data is transmitting.
2.
PoE LED
Solid green: Ethernet cable is connected, but no data transmission.
Quick flashing green: Ethernet cable is connected, and data is transmitting.
3.
5GHz / 2.4GHz LED
Solid green: Wi-Fi is ready.
Quick flashing green: Transmitting or receiving data via Wi-Fi connection.
4.
Power LED
Solid green: BAP-AC1750 is ready.
Slow flashing green
•   BAP-AC1750 is trying to reach the access controller.
•   BAP-AC1750 is updating its firmware.
•   BAP-AC1750 is resetting to its default settings.
Quick flashing red
•   BAP-AC1750 is either in an uninitialized state, or cannot reach the access controller.
NOTE:   When power LED is off and all the other LEDs are solidly lit up, this indicates that the controller
daemon (CAPWAP) crashed.
5.
Kensington security slot
Insert a Kensington lock into this hole to keep your BAP-AC1750 safe.
6.
Power (DC-IN) port
Insert the bundled DC adapter into this port and connect to a power source.
7.
Reset button
This button resets or restores the system to its factory default settings.
8.
USB port
Insert a USB device such as a USB flash drive into the port.
9.
Ethernet (LAN) port
Connect a network cable into this port to establish Ethernet connection.
10.
Follow these guidelines to get the maximum coverage:
• Place your BAP-AC1750 in a centralized area.
• Do not install your BAP-AC1750 near metal objects such as heating ducts, metal
doors, or electric service panels.
• If you are installing more than one BAP-AC1750, place them about 80 feet apart.
• When you install your BAP-AC1750 on a pole, the coverage is 180 degrees.
NOTE:		 Do not mount two BAP-AC1750s back to back on a pole to achieve a 360 degrees
coverage. The two BAP-AC1750 could interfere with each other.
Mounting options
Mounting your BAP-AC1750 to the
bracket and to the wall
128mm
1. Drill four 6.5mm holes on the wall.
2. Place four 6.5mm M6 plastic anchors in the
four holes.
3. Tighten the bracket to the wall with four
3mm round head drywall screws.
4. Align and install your BAP-AC1750 into the
bracket.
PoE port
Insert a network cable into this port to establish Ethernet connection and provide DC power input.
On the ceiling tile
1. When the T-bar width is more than 24mm or has a reveal edge treatment, drill
four holes on the tile.
2. Cut about 25 mm rectangular hole on the tile for the Ethernet cable feed.
3. Attach the bracket to the tile with the four bundled truss head machine screws.
4. Tighten the bracket to the tile with the four bundled  jam nuts and flat washers.
5. Align and install your BAP-AC1750 into the bracket.
wall
Unmounting your BAP-AC1750
Via a PoE compliant power source
Press the notch on the bracket to
unmount your BAP-AC1750.
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
POE Switch
Standard Switch
OR
POE Switch
POE Injector
IMPORTANT!    Use only the DC adapter that came with your package or an 802.3at compliant
PoE power source. Using other DC adapters may damage your BAP-AC1750.
Securing your BAP-AC1750
1. Locate the Kensington
security slot on your BAPAC1750.
2. Insert a Kensington lock
into the security slot and
secure it to an immovable
object.
NOTES:
•
•
•
Connecting the power supply
When both the DC adapter and PoE power source are plugged to your BAP-AC1750, the
DC power is the primary source of your BAP-AC1750. When the DC power fails, your BAPAC1750 changes to the 802.3at PoE source.
BAP-AC1750 can be powered by 802.3at compliant (25.5W) PoE switch/PoE injector or
802.3af compliant (12.95W) PoE switch/PoE injector. When your BAP-AC1750 is operated
on 802.3af power, the USB port is disabled, and the TX power reduces 3dB from power by
802.3at.
Environment Specifications:
Temperature
-5°C to 50 degrees °C (OperatingTemperature)
-20°C to 70°C (Storage Temperature)
Operating humidity
- 5% to 95% (Noncondensing)
You can connect either the bundled DC adapter or an 802.3at power source to your
BAP-AC1750.
Via the DC adapter
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Standard Switch
E12038 / First Edition / October 2016
E12038_BAP-AC1750_QSG.indd 1
2016/11/1 17:10:30
Safety Notices
ASUS Recycling/Takeback Services
Canada, avis d’Industry Canada (IC)
Networks Global Hotline Information
•
•
•
ASUS recycling and takeback programs come from our commitment to the highest standards
for protecting our environment. We believe in providing solutions for you to be able to
responsibly recycle our products, batteries, other components, as well as the packaging
materials. Please go to http://csr.asus.com/english/Takeback.htm for the detailed recycling
information in different regions.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1)
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
Region
Read, follow, and keep these instructions.
Heed all warnings.
Only use attachments/accessories specified by the manufacturer.
WARNING!
•
•
Do not use this product in location that can be submerged by water.
Avoid using this product during an electrical storm. There may be a remote risk of electric
shock from lightning.
Electrical Safety Information
•
•
•
Compliance is required with respect to voltage, frequency, and current requirements
indicated on the manufacturer’s label. Connection to a different power source than
those specified may result in improper operation, damage to the equipment or pose a
fire hazard if the limitations are not followed.
There are no operator serviceable parts inside this equipment. Service should be
provided only by a qualified service technician.
This equipment is provided with a detachable power cord which has an integral safety
ground wire intended for connection to a grounded safety outlet.
a)	Do not substitute the power cord with one that is not the provided approved
type. Never use an adapter plug to connect to a 2‐wire outlet as this will defeat the
continuity of the grounding wire.
b)	The equipment requires the use of the ground wire as a part of the safety
certification, modification or misuse can provide a shock hazard that can result in
serious injury or death.
c) Contact a qualified electrician or the manufacturer if there are questions about the
installation prior to connecting the equipment.
d)	Protective earthing is provided by Listed AC adapter. Building installation shall
provide appropriate short‐circuit backup protection.
e)	Protective bonding must be installed in accordance with local national wiring
rules and regulations.
Limited Warranty
ASUSTeK Inc. warrants that the product(s) furnished hereunder (the “Product(s)”) shall be free
from defects in material and workmanship for a period of three years from the date of shipment
by ASUSTek Inc. under normal use and operation. ASUSTek sole and exclusive obligation and
liability under the foregoing warranty shall be for ASUSTek Inc. , at its discretion, to repair or
replace any Product that fails to conform to the above warranty during the above warranty
period. The expense of removal and reinstallation of any Product is not included in this
warranty. The warranty period of any repaired or replaced Product shall not extend beyond its
original term.
Warranty Limitations
The above warranty can be applied with following terms:
• This warranty is can be availed by the first buyer only and is not transferable from one
user to another.
• The warranty excludes demonstration/installation of the product purchased.
• If customer purchases the product from overseas market that has a local warranty, the
product is repairable at additional charges.
• In the event of repairs/replacement of any parts of the unit, this warranty will thereafter
continue and remain in force only for the unexpired period of the warranty.
• Moreover time taken for repair/replacement and in transit whether under the warranty
or otherwise shall not be excluded from the warranty period.
• ASUS will not be responsible for loss of any data on the network devices, under any
circumstances. Customers are encouraged to back up all data stored from your side
before giving to service center.
• ASUS’ liability shall be subject to the rates and terms of the ASP performing such
services. All third party peripherals whether purchased as a part of the system or
bundled with it, normally come with the prevailing suppliers warranty and ASUS does
not warranty error free or uninterrupted operation of the equipment.
The above warranty does not apply if the Product:
• Original serial number is removed, obliterated or altered from the product or cabinet
modification, except by ASUSTek, or ASUSTeks’ authorized representatives, or as
approved by ASUSTek in writing.
• Defects or damage due to non-recommended softwares added by customer or virus
attack.
• Not used as per instructions in the user’s manual.
• Any defects caused due to misuse, abuse, negligence, abnormal physical,
electromagnetic or electrical stress, including lightning strikes, or accident Natural
calamities while in transit to service centre or purchasers’ residence.
• Premises where the product is kept in conditions that do not conform to recommended
operating conditions of the machine.
• The product being serviced or repaired by anyone or un-trained engineer other than
Authorized service Provider and modification from original ASUS manufacturing
standard.
• Has been painted, rebranded or physically modified in any way.
• Has been damaged or impaired as a result of using third party firmware
• Exposing the products to water on any circumstances by the user.
In addition, the above warranty shall apply only if: the product has been properly installed
and used at all times in accordance, and in all material respects, with the applicable Product
documentation; all Ethernet cabling runs use CAT5 (or above), and for indoor installations,
indoor cabling requirements are followed.
E12038_BAP-AC1750_QSG.indd 2
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 40cm
between the radiator & your body.
IMPORTANT!   This device within the 5.15 ~ 5.25 GHz is restricted to indoor operations to
reduce any potential for harmful interference to co-channel MSS operations.
•
•
•
•
•
•
•
WARNING!
•
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
• Users must not modify this device. Modifications by anyone other than the party responsible
for compliance with the rules of the Federal Communications Commission (FCC) may void
the authority granted under FCC regulations to operate this device.
• For product available in the USA/Canada market, only channel 1~11 can be operated.
Selection of other channels is not possible.
•
•
This device and its antenna(s) must not be co-located or operating in conjunction with
any other antenna or transmitter except in accordance with FCC multi-transmitter product
procedures.
Safety Information
To maintain compliance with FCC’s RF exposure guidelines, this equipment should be installed
and operated with minimum distance 40cm between the radiator and your body. Use on the
supplied antenna.
Declaration of Conformity for R&TTE directive 1999/5/EC
Essential requirements – Article 3
Protection requirements for health and safety – Article 3.1a
Testing for electric safety according to EN 60950-1 has been conducted. These are considered
relevant and sufficient.
Protection requirements for electromagnetic compatibility – Article 3.1b
Testing for electromagnetic compatibility according to EN 301 489-1 and EN 301 489-17 has
been conducted. These are considered relevant and sufficient.
Effective use of the radio spectrum – Article 3.2
Testing for radio test suites according to EN 300 328 & EN 301 893 have been conducted. These
are considered relevant and sufficient.
Operate the device in 5150-5250 MHz frequency band for indoor use only.
For product available in the USA/Canada market, only channel 1~11 can be operated.
Selection of other channels is not possible.
Pour les produits disponibles aux États-Unis / Canada du marché, seul le canal 1 à 11
peuvent être exploités. Sélection d'autres canaux n'est pas possible.
This device and it's antennas(s) must not be co-located or operating in conjunction with
any other antenna or transmitter except in accordance with IC multi-transmitter product
procedures.
Cet appareil et son antenne (s) ne doit pas être co-localisés ou fonctionnement en
association avec une autre antenne ou transmetteur.
Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain approved f or the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type should be
chosen so that the equivalent isotropically radiated power (e.i.r.p) is not more than that
necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé
pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son
gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas
l'intensité nécessaire à l'établissement d'une communication satisfaisante.
This radio transmitter (3568A-RTGW00) has been approved by Industry Canada to operate
with the antenna types listed below with the maximum permissible gain and required
antenna impedance for each antenna type indicated. Antenna types not included in this list,
having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
Le présent émetteur radio (3568A-RTGW00) a été approuvé par Industrie Canada pour
fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible
maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus
dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement
interdits pour l'exploitation de l'émetteur.
The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for
harmful interference to co-channel mobile satellite systems.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement
pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux
systèmes de satellites mobiles utilisant les mêmes canaux.
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變
更頻率、加大功率或變更原設計之特性及功能。低功率射頻電機之使用不得影響飛
航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方
得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機
須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。
Canada, Industry Canada (IC) Notices
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Radio Frequency (RF) Exposure Information
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 40cm
between the radiator & your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de
40cm de distance entre la source de rayonnement et votre corps.
Korea
Thailand
Asia-Pacific
Singapore
Malaysia
Philippines
India
India(WL/NW)
Americas
Middle East + Africa
1800-2090365
Indonesia
0062-2129495000
500128 (Local Only)
Vietnam
1900-555581
Hong Kong
USA
Canada
00852-35824770
Mexico
001-8008367847
Egypt
Saudi Arabia
UAE
Turkey
South Africa
800-2787349
800-1212787
00971-42958941
0090-2165243000
0861-278772
*6557/00972-39142800
*9770/00972-35598555
0040-213301786
00387-33773163
00359-70014411
00359-29889170
00385-16401111
00382-20608251
00381-112070677
00368-59045400
00368-59045401
00372-6671796
00371-67408838
00370-37329000
00370-522101160
Israel
Romania
Bosnia Herzegovina
Bulgaria
Balkan Countries
0082-215666868
0066-24011717
1800-8525201
0065-64157917
0065-67203835
(Repair Status Only)
0060-320535077
1800-18550163
Croatia
Montenegro
Serbia
Slovenia
Estonia
Latvia
Lithuania-Kaunas
Lithuania-Vilnius
1-812-282-2787
Service Hours
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-17:00 Sat-Sun
09:00-18:00 Mon-Fri
09:00-17:00 Sat-Sun
09:30-17:00 Mon-Fri
09:00-18:00 Mon-Fri
11:00-19:00 Mon-Fri
11:00-19:00 Mon-Fri
11:00-13:00 Sat
10:00-19:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Sat
09:00-21:00 Mon-Sun
09:30-17:00 Mon-Fri
9:30 – 12:00 Sat
08:00-12:00
13:30-17:30 Mon-Sat
10:00-19:00 Mon-Sat
8:30-12:00 EST Mon-Fri
9:00-18:00 EST Sat-Sun
08:00-20:00 CST Mon-Fri
08:00-15:00 CST Sat
09:00-18:00 Sun-Thu
09:00-18:00 Sat-Wed
09:00-18:00 Sun-Thu
09:00-18:00 Mon-Fri
08:00-17:00 Mon-Fri
08:00-17:00 Sun-Thu
08:30-17:30 Sun-Thu
09:00-18:30 Mon-Fri
09:00-17:00 Mon-Fri
09:30-18:30 Mon-Fri
09:30-18:00 Mon-Fri
09:00-17:00 Mon-Fri
09:00-17:00 Mon-Fri
09:00-17:00 Mon-Fri
08:00-16:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
NOTE:   For more information, visit the ASUS support site at: http://support.asus.com
Networks Global Hotline Information
Region
Country
Hotline Number
Cyprus
800-92491
France
Hungary
0033-170949400
0049-1805010920
0049-1805010923
( component support )
0049-2102959911 ( Fax )
0036-15054561
Italy
199-400089
Greece
00800-44142044
Austria
Netherlands/
Luxembourg
Belgium
Norway
Sweden
Finland
Denmark
Poland
Spain
Portugal
Slovak Republic
Czech Republic
Switzerland-German
Switzerland-French
Switzerland-Italian
United Kingdom
Ireland
Russia and CIS
Ukraine
0043-820240513
09:00-17:30 Mon-Fri
09:00-13:00 ;
14:00-18:00 Mon-Fri
09:00-13:00 ;
14:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
0031-591570290
09:00-17:00 Mon-Fri
0032-78150231
0047-2316-2682
0046-858769407
00358-969379690
0045-38322943
0048-225718040
0034-902889688
00351-707500310
00421-232162621
00420-596766888
0041-848111010
0041-848111014
0041-848111012
0044-8448008340
0035-31890719918
008-800-100-ASUS
0038-0445457727
09:00-17:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
10:00-19:00 Mon-Fri
09:00-18:00 Mon-Fri
08:30-17:30 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
08:00-17:00 Mon-Fri
08:00-17:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-17:00 Mon-Fri
09:00-17:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
Germany
CE Mark Warning
This is a Class B product, in a domestic environment, this product may cause radio interference,
in which case the user may be required to take adequate measures.
This equipment may be operated in AT, BE, CY, CZ, DK, EE, FI, FR, DE, GR, HU, IE, IT, LU, MT, NL, PL,
PT, SK, SL, ES, SE, GB, IS, LI, NO, CH, BG, RO, RT.
Japan
0081-570783886 (Non-Toll Free)
NCC 警語
Prohibition of Co-location
Hotline Number
1300-278788
0800-278788
0800-1232787
WARNING!
•
Country
Australia
New Zealand
Europe
Service Hours
09:00-13:00 ;
14:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
09:00-18:00 Mon-Fri
10:00-17:00 Mon-Fri
2016/11/1 17:10:31

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2016:11:01 17:10:29+08:00
Metadata Date                   : 2017:01:06 17:10:49+08:00
Modify Date                     : 2017:01:06 17:10:49+08:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:690f8bcc-7415-4faa-8c51-d09e47d9989d
Original Document ID            : xmp.did:8756A4E40F74E6119BFDB8D74C64D386
Document ID                     : xmp.id:9EFEB39A12A0E6118F31BA41060C60BD
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:EBFC163212A0E6118F31BA41060C60BD
Derived From Document ID        : xmp.did:021C0AC24D97E611A75EF82D9F46DC59
Derived From Original Document ID: xmp.did:8756A4E40F74E6119BFDB8D74C64D386
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2016:11:01 17:10:29+08:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MSQ-BAPAC1750

Navigation menu