AVALUE TECHNOLOGY ORPORATION AID173 Panel PC User Manual AID 173S QRG 2011 05 13 STD

Avalue Technology Inc. Panel PC AID 173S QRG 2011 05 13 STD

manual

Download: AVALUE TECHNOLOGY ORPORATION AID173 Panel PC User Manual AID 173S QRG 2011 05 13  STD
Mirror Download [FCC.gov]AVALUE TECHNOLOGY ORPORATION AID173 Panel PC User Manual AID 173S QRG 2011 05 13  STD
Document ID1467976
Application IDJiNSEg3BFC4Dku7QGlx2yg==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize150.1kB (1876287 bits)
Date Submitted2011-05-19 00:00:00
Date Available2011-05-19 00:00:00
Creation Date2011-05-13 15:08:14
Producing SoftwareBullzip PDF Printer / www.bullzip.com / Freeware Edition
Document Lastmod2011-05-18 15:52:57
Document TitleMicrosoft Word - AID-173S QRG 2011-05-13 _STD_.doc
Document CreatorUnknownApplication
Document Author: jay_wu

Avalue Intelligent Display & Systems
AID-173S
All-In-One Bedside Terminals
Quick Reference Guide
1st Ed- 15 October 2010
Copyright © 2010 Avalue Technology Inc., All Rights Reserved
By Jason Lin
AID-173S Quick Reference Guide
Federal Communication Commission Interference Statement
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT
TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Notice:
(1) A Unshielded-type power cord is required in order to meet FCC emission limits and
also to prevent interference to the nearby radio and television reception. It is
essential that only the supplied power cord by used.
(2) Use only shielded cables to connect I/O devices to this equipment.
(3) Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
AID-173S Quick Reference Guide
AID-173S Quick Reference Guide
FCC RF Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20cm between the radiator & your body.
For product available in the USA/Canada market, only channel 1~11 can
be operated. Selection of other channels is not possible. The antenna(s)
used for this transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter. Shielded interface
cables must be used in order to comply with emission limits.
AID-173S Quick Reference Guide
AID-173S Quick Reference Guide
CONTENT
1. AID-173S Bedside Terminals Features ...........................................................5
1.1 Front Look .........................................................................................6
1.2 Rear & Bottom Look .........................................................................7
1.3 Handset..............................................................................................8
2. Setting Up AID-173S Bedside Terminals........................................................9
2.1 Mounting..........................................................................................10
2.2 Cabling.............................................................................................11
2.3 System Activation & Registration .................................................12
2.4 Connecting to the Internet .............................................................13
3. Using AID-173S Bedside Terminals...............................................................14
3.1. Turn ON/OFF the System ..............................................................15
3.2 Using LCD Display and Touch Screen..........................................16
3.3 Using Earphone and Microphone ..................................................17
3.4 Using the Smart Card Reader ........................................................18
3.5 Using Magnetic Strip Reader .........................................................19
4.
3.6 Using RFID Reader/Writer ..............................................................20
3.7 Using Handset.................................................................................21
3.8 Using Barcode Scanner .................................................................23
Upgrading AID-173S Bedside Terminals ..................................................24
4.1 Adding/Removing/Replacing Memory ..........................................25
4.2 Adding/Removing/Replacing TV Tuner.........................................26
4.3 Removing and Replacing the Wireless Card................................27
4.4 Adding 3rd Party Mini-PCIe Cards ................................................28
4.5 Removing and Replacing the Hard Disk Drive .............................29
AID-173S Quick Reference Guide
AID-173S Quick Reference Guide
1. AID-173S Bedside Terminals Features
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
In this chapter, you will learn all of the features of AID-173S bedside
terminals.
1.1 Front Look
1.2 Rear & Bottom Look
1.3 Handset
AID-173S Quick Reference Guide
AID-173S Quick Reference Guide
1.1 Front Look
Magnetic Strip Reader
17.3” TFT-LCD & Touch Screen
Camera
Handset
3 x USB
RFID Reader/Writer
Cord
Power on/off
Smart Card Reader
Reserved
AID-173S Quick Reference Guide
Brightness
Volume
Up/down
Up/down
AID-173S Quick Reference Guide
1.2 Rear & Bottom Look
LAN
HDMI Output (optional)
TV Antenna Input (optional)
DVI-I Output (Optional, 1024*768)
USB Port
DC in
Service Door
Speaker
Speaker
Microphone
BNC Video Input (Optional)
Nursing Call Input
AID-173S Quick Reference Guide
COM2
COM1
AID-173S Quick Reference Guide
1.3 Handset
Barcode Scanner
Volume
Scan button
Key
Descriptions
Activate the phone software (i.e. Skype)
Nurse Call
Answer
Hang Up
Contact List Up
Contact List Down
Numeric Keys
* Key
# Key
AID-173S Quick Reference Guide
AID-173S Quick Reference Guide
2. Setting Up AID-173S Bedside Terminals
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
In this chapter, you will learn how to set up AID-173S bedside
terminal hardware and cable connection. Finally, with Internet ISP
setting information, you will be able to connect AID-173S bedside
terminal to the Internet.
2.1 Mounting
2.2 Cabling
2.3 System Activation & Registration
2.4 Connecting to the Internet
AID-173S Quick Reference Guide
AID-173S Quick Reference Guide
2.1 Mounting
VESA 75 Mounting
Suggested Mounting Screws
Note: 4 pieces of M6x10 screws
AID-173S Quick Reference Guide
10
AID-173S Quick Reference Guide
2.2 Cabling
1. Power Cable
2. Ethernet (RJ-45) Cable (Optional)
3. TV (Coaxial) Cable (Optional)
Coaxial connector
Ethernet (RJ-45)
Connector
Power Jack
Please follow below steps to connect the power cable and the system.
AID-173S Quick Reference Guide
11
AID-173S Quick Reference Guide
2.3 System Activation & Registration
1. When you first receive the system, a system activation and software
registration might be performed before the use of this system.
2. Please consult your local service providers for more details.
AID-173S Quick Reference Guide
12
AID-173S Quick Reference Guide
2.4 Connecting to the Internet
1. Use built-in wireless LAN to connect to the Internet.
2. Use Ethernet (RJ-45) to connect to the Internet.
3. Consult your Internet Service Provider (ISP) for software settings.
Note: ISP, IP, (wireless) router, Access Point, DSL modem, Access ID &
Password, and so on, are needed for Internet access.
AID-173S Quick Reference Guide
13
AID-173S Quick Reference Guide
3. Using AID-173S Bedside Terminals
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
In this chapter, you will learn how to use all the features of
AID-173S bedside terminal.
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
Turn ON/OFF the System
Using LCD Display and Touch Screen
Using Ear Phone and Microphone
Using Smart Card Reader
Using Magnetic Strip Reader
Using RFID Reader/Writer
Using Handset
Using Barcode Scanner
AID-173S Quick Reference Guide
14
AID-173S Quick Reference Guide
3.1. Turn ON/OFF the System
ON/OFF Touch Button
3.1.1 Turn ON the System
1.
2.
3.
4.
Check if the led on the Power ON/OFF icon is red.
Move your finger on the top of the Power ON/OFF icon.
The led on the Power ON/OFF icon turns green.
Now the system is turned ON.
3.1.2 Turn OFF the System
1. Move your finger on the top of the Power ON/OFF icon for about 4
seconds.
2. The led on the Power ON/OFF icon turns red.
3. The system is turned OFF.
Note: We recommend use the operating system shut down procedures to turn
OFF the system.
AID-173S Quick Reference Guide
15
AID-173S Quick Reference Guide
3.2 Using LCD Display and Touch Screen
Control Buttons
3.2.1 Adjust System Volume
1. Move your finger on the top of the Volume Up or Volume Down icon.
2. The volume will be adjusted accordingly.
3.2.2 Adjust LCD Display Brightness
1. Move your finger on the top of the Brightness Up or Brightness Down
icon.
2. The brightness of the LCD display will be adjusted accordingly.
3.2.3 Using Touch Screen
1. To select the item on the touch screen, press the item once.
2. To select and open the item, press the item twice quickly.
3. To open the secondary menu, press and hold until the menu appears and
then moving your finger to select the menu item. When you determine
the menu item, release your finger and the item is selected.
AID-173S Quick Reference Guide
16
AID-173S Quick Reference Guide
3.3
Using Earphone and Microphone
1. Open the rubber cover on the right side of the system.
2. Insert the earphone phone or microphone into the jacks.
AID-173S Quick Reference Guide
17
AID-173S Quick Reference Guide
3.4 Using the Smart Card Reader
1. Have the IC card face up.
2. Insert the IC card into the Smart Card Reader slot.
AID-173S Quick Reference Guide
18
AID-173S Quick Reference Guide
3.5 Using Magnetic Strip Reader
1. Have your card with the magnetic strip facing outside.
2. Slide the card from top to the bottom.
AID-173S Quick Reference Guide
19
AID-173S Quick Reference Guide
3.6 Using RFID Reader/Writer
1. Attach the card to the RFID Reader/Writer. Keep card close to the
reader no greater than 5cm.
2. The RFID will beep if the card is read or written successfully.
Note: The RFID Reader/Writer accepts ISO 14443A standard cards ONLY.
AID-173S Quick Reference Guide
20
AID-173S Quick Reference Guide
3.7 Using Handset
Take the Handset
1. When you want to use the handset, lift the handset from the cradle.
2. Replace the handset back to the handset cradle with keypad facing
inside.
AID-173S Quick Reference Guide
21
AID-173S Quick Reference Guide
Start and End a Phone Conversation
1. To make a phone call, enter the
numbers by press the number on
the keypad and press “Dial” icon.
2. To end a phone conversation,
press the “Hang Up” icon.
3. Use the volume control to adjust
the volume of the handset.
Note: Phone application software and
Internet connection are required.
AID-173S Quick Reference Guide
22
AID-173S Quick Reference Guide
3.8 Using Barcode Scanner
1. Take the handset and turn it over.
2. Aim the barcode and maintain an appropriate distance between and
barcode and scanner.
3. Press SCAN button.
4. The Barcode Scanner will “Beep” when the barcode is successfully read.
AID-173S Quick Reference Guide
23
AID-173S Quick Reference Guide
4. Upgrading AID-173S Bedside Terminals
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
In this chapter, you will learn several peripherals upgrade or
replacement. Please perform these steps with care.
▲ WARNING: Turn OFF the system and disconnect the power
cable before performing the following tasks.
▲CAUTION: Only a certified service technician is authorized to
remove the cover and access the components inside the system.
4.1 Adding/Removing/Replacing Memory
4.2 Adding/Removing/Replacing TV Tuner
4.3 Removing and Replacing the Wireless Card
4.4 Adding 3rd Party Mini-PCIe Cards
4.5 Removing and Replacing the Hard Disk Drive
AID-173S Quick Reference Guide
24
AID-173S Quick Reference Guide
4.1 Adding/Removing/Replacing Memory
1. Remove the two screws from
the service door.
2. Open the service door.
1. Push the two latches of the
retaining clips away from the
memory module.
2. The memory module will pop
up at an angle.
3. Lift the memory module from
the memory socket.
1. Align the correct location of
the key slot on the connector
edge.
2. Slide the memory module into
the memory socket.
3. Push the memory module
down until the retaining clip
latches catch.
4. Close the service door.
5. Insert the two screws on the
service door.
Note: Please use the correct type of memory on both memory sockets.
AID-173S Quick Reference Guide
25
AID-173S Quick Reference Guide
4.2 Adding/Removing/Replacing TV Tuner
1. Remove the two screws from
the service door.
2. Open the service door.
1.
Unplug the TV signal cable.
2.
3.
Unlock the mini-PCIe socket.
Pull the TV module out of the
socket.
1. Place the TV module into the
mini-PCIe socket.
2. Lock the mini-PCIe socket.
3. Connect the TV signal cable to
the TV module.
4. Close the service door.
5. Insert the two screws on the
service door.
AID-173S Quick Reference Guide
26
AID-173S Quick Reference Guide
4.3 Removing and Replacing the Wireless Card
1. Remove the two screws from
the service door.
2. Open the service door.
1. Unplug the two antennas from
the wireless module.
2. Unlock the mini-PCIe socket.
3. Pull the wireless module out of
the socket.
1. Place the wireless module into
the mini-PCIe socket.
2. Lock the mini-PCIe socket.
3. Connect the two antenna to the
wireless module.
4. Close the service door.
5. Insert the two screws on the
service door.
AID-173S Quick Reference Guide
27
AID-173S Quick Reference Guide
4.4 Adding 3rd Party Mini-PCIe Cards
1. Remove the two screws from
the service door.
2. Open the service door.
1. Insert the 3rd party mini-PCIe
card into the empty mini-PCIe
expansion socket.
2. Lock the mini-PCIe socket.
Close the service door and insert
two screws.
AID-173S Quick Reference Guide
28
AID-173S Quick Reference Guide
4.5 Removing and Replacing the Hard Disk Drive
1. Remove the two screws from
the service door.
2. Open the service door.
1. Remove the two top screws
from the hard bracket from the
hard disk cage.
2. Disconnect the power and data
cables from the back of the hard
disk drive.
3. Lift the top of the hard disk drive
bracket and pull the hard disk
drive from the cage.
Remove the two screws on the
bracket from the hard disk.
Continue on next page…
AID-173S Quick Reference Guide
29
AID-173S Quick Reference Guide
1. Insert the two screws on the
bracket.
2. Place the hard disk drive into
the cage.
3. Insert two screws on the
bracket and the cage.
4. Connect the power and data
cable to the hard disk drive.
5. Close the service door and
insert two screws.
End of This Document
AID-173S Quick Reference Guide
30
AID-173S Quick Reference Guide
Thank you for purchasing and using AID-173S Bedside Terminals.
We hope you have a joyful experience with our products and services.
AID-173S Quick Reference Guide
31

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : 3.1-702
About                           : 44a408a0-7f8b-11e0-0000-aec4db117a2b
Producer                        : Bullzip PDF Printer / www.bullzip.com / Freeware Edition
Modify Date                     : 2011:05:18 15:52:57+02:00
Create Date                     : 2011:05:13 15:08:14+08:00
Creator Tool                    : UnknownApplication
Metadata Date                   : 2011:05:18 15:52:57+02:00
Document ID                     : 44a408a0-7f8b-11e0-0000-aec4db117a2b
Instance ID                     : uuid:9ee6c37a-cb04-4e93-b34b-5b95472286ef
Format                          : application/pdf
Title                           : Microsoft Word - AID-173S QRG 2011-05-13 _STD_.doc
Creator                         : jay_wu
Page Count                      : 31
Author                          : jay_wu
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XBG-AID173

Navigation menu