AVITA SCW-10XX Bluetooht Weight Scale User Manual Instruction Manual
AVITA Corporation Bluetooht Weight Scale Instruction Manual
AVITA >
User Manual
Model : SC101
Before Use
Precautions………………………………....1
Scale Components………………………... 2
Error Displays..…………………………..... 3
Installing(or Replacing) Batteries …….... 4
Measurement weight……….………………6
Wireless connection…………….………… 8
References
Specifications……………………………… 9
Maintaining the Scale……………..……... 9
FCC Staeement.................................10
Operations
Specifications SC101
Read Before Use
Type BF Applied Part
!Please read this booklet before using your scale.
!Do not place your scale on a soft, wet or slippery
floor.It is recommended that the scale be used on
a solid level surface, such as tile, wood, or
laminate flooring.
!Place your scale on a solid level flooring surface.
Your scale contains delicate, high-precision
parts. Avoid extremes in the temperature,
humidity, direct sunlight,shock , moisture and
dust.
!Do not disassemble repair, or remodel the scale.
!Do not step onto your scale with wet feet. Make
certain that feet are dry to prevent slipping or
serious injury.
!Do not step on the edge.
!Do not place feet on the display window.
Precautions
1
Indications for use
Scale components
!This scale is designed for indoor use to measure
the weight.
Display Front
Back
Bluetooth
Slide Mod
RESET
KG/L
2
!The following measurement can be selected by
slide switch and are classified into two
categories WEIGHT MODE and WEIGHT
CONNECTION MODE, you have choice to
select and have your weight displayed in KG or
LB.
!The scale has an “automatic- power-off”
function to turn off in about sixty seconds after
non-operation.
3
Error Display
Low battery mark
(Replace the batteries
with new ones)
Your weight is overload
Installing (or Replacing) Batteries
Caution:
!Insert the battery with the positive (+) and
negative (-) terminals properly aligned with the
corresponding symbols in the battery
compartment.
!Improper installation of the batteries may
cause battery leakage.
!Replace all four batteries with new ones, when
“Lo” symbol is displayed.
!Do not mix used and new batteries. It may
result in damage to the scale or shorten battery
life.
!The battery life is dependant upon the
environmental temperature, battery type and
usage.
!Remove the batteries from the battery
compartment, when the scale is not to be used
for a long time. They may leak and damage
your scale.
!Discard waste batteries according to the local
law.
4
5
Steps for Installing (or Replacing) Batteries
1. Remove the battery
compartment cover on
the underside of the
scale by gently pushing
on the arrow and lifting
the cover backward.
2. Place four new batteries
with the positive (+) and
negative (-) terminals
properly aligned with the
corresponding symbols
in the battery compartment.
3. Replace the cover by sliding
it into the compartment and
gently pressing into place.
6
Measurement Weight
Measurement Your Weight
1. Slide switch to correct
Mode Example
A: Set the slide switch to
“BLUETOOTH ON”, Tap
on the scale,the scale
will calibrate and display
. Bluetooth indicator
light to flash, Means
Bluetooth connection is
open. (Concrete
operation please look at in
wireless connection)
B. Set the slide switch to
“BLUETOOTH OFF”,Tap
on the scale, the scale ill
calibrate and display .
Bluetooth indicator light
is power-off, This is
measurement weight
only All display segments
are visible for three
seconds.
Wait until 0.00 is displayed.
(The display show
0.00kg/0.00lb)
7
Step on the scale and position
your feet in a manner that will
distribute your weight evenly
over the entire scale platform.
The LCD display will flash two
times, then the display will
show your weight. Stand still
while reading the display.
Now you step off the scale,
the display will show
0.00kg/0.00lb,You can
measurement your weight
again.
(Caution: If you remain standing on the scale
or step off the scale without sixty seconds after
your weight has displayed and then turn off
automatically).
Wireless Connection
1.Turn the Scale to the back side.
2.Turn on the bluetooth switch (From “0” to “1”),
while the device is performing an inquiry to find
other devices to which to connect, the LED on
the front side of the Scale will be quickly flashing.
When the device connects successfully to health
Monitoring devices, such as a computer or a
mobile phone, the LED is keeping on shining. At
the end of the measurement, your Scale will be
sent to your health monitoring device.
3.To disconnect from health monitoring devices,
turn off the bluetooth switch (From “1” to “0”),
then the LED will stop shining.
Back
Bluetooth
Slide Mod
RESET
KG/L
8
9
Digital display Liquid crystal display,
38mm character height
Maximum capacity 200kg/440lb
Minimum display 0.05kg/0.11lb
Bluetooth connection BlueMod+B20 (
Stollmann E+V GMBH))
Power source Four type AAA
batteries (1.5 volt X 4, included)
Battery life Approximately 1000
Measurements
5℃~35℃,30~85%RH
-20℃~60℃,10~95%RH
Specifications are subjects to change without
prior notice and any obligation on the part of the
manufacturer.
□Clean the scale with a dry, soft cloth or a
cloth moistened with water and a mild
detergent. Never use alcohol, benzene,
thinner or other harsh chemicals to clean
the scale.
□Remove the batteries, if the scale is not
going to be used for a long time.
Specifications SC101
Maintaining the scale
Operation Environment
Storage & Transportation
Environment
FCC Statement
FCC Caution: Any changes or modifications not
expressly approved by the party responsible for
compliance could void the user's authority to
operate this equipment.
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
This device and its antenna(s) must not be co-
located or operating in conjunction with any other
antenna or transmitter.
10
EU Representative:
Golden Star Computer (UK) Ltd.,
Unit 39, Rainbow Industrial Estate,
Trout Road, West Drayton,
Middx. UB7, 7RN, United Kingdom
AViTA Corporation
9F, No.78, Sec.1, Kwang-Fu Rd.,
San-Chung, Taipei County,
Taiwan
No.28 Xinyang Road,
Economic Development Zone,
Yangzhou City, Jiangsu Province,
China 225009
EC REP