Setup & Installation 11Chapter 24/3/03 Accton Draft—CONFIDENTIALWhen prompted, log in to the Aruba WLAN Switch as the administrator:user: adminpassword: <administrator password (not displayed)>This will present you with the Aruba WLAN Switch SOE console prompt (soe>).Specify the physical Aruba WLAN Switch port to which the new Aruba 50 is con-nected:soe> connect <slot number>/<port number>This will present you with the Aruba 50 console prompt (#). Once connected to the console, follow the instruction on page 12 to configure Aruba 50.Direct Terminal ConnectionUse this procedure when connecting the Aruba 50 through the LAN or to a non-SPOE net-work port on the Aruba WLAN Switch. Under these topologies, a direct terminal connection is required for initial setup.NOTE—If connecting the Aruba 50 directly to a SPOE network port on the Aruba WLAN Switch, see the instructions on page 10.Set up your local terminal.This procedure requires a terminal or computer running terminal emulation software with the following settings:Connect the terminal directly to the Aruba 50.Use a standard serial cable to connect the Aruba 50 console port to a serial port on your termi-nal (see Appendix B for port specification).Establish console communication.Press <Enter> a few times to establish communication between the terminal and the Aruba 50. You will be presented the Aruba 50 console prompt (#).Once connected to the Aruba 50 console, follow the instruction on page 12 to configure the device.TABLE 2-1 Console Terminal SettingsBaud Rate Data Bits Parity Stop Bits Flow Control9600 8 None 1 None45123
4/3/03 Accton Draft—CONFIDENTIAL12 Aruba 50 Part 0500007AInstallation Guide May 2003Configure the Aruba 50From the Aruba 50 console, access the boot prompt.Reboot the Aruba 50 and then immediately (within three seconds as the device is booting) press any key to interrupt the process:# boot<Any key (while booting)>This will present you with the Aruba 50 boot prompt (apboot>).Set the intended location for the Aruba 50:apboot> setenv location <building number>.<floor number>.<device number>If you performed the recommended site survey using the Aruba WLAN Switch’s built-in planning tools, the location data for all access points and air monitors can be found on the tool’s deployment screen (see the Aruba AirOS Software Guide).If you plan to manually generate the location data, record the following information for each access point and air monitor. It will be required when configuring the Aruba WLAN Switch.Building Number A unique number (1-255) is required for each building in your campus.Floor Number Within any building, a unique number (1-255) is required for each floor.Device Number Within any floor, a unique number (1-65536) is required for each access point or air monitor.Device Description Note the intended function of the device (access point or dedicated air monitor) and a brief description of its service location.X, Y Coordinates For each access point and air monitor, measure its X and Y position (in feet) relative to the bottom-left corner of the building plan as seen from overhead. For example:Use the same fixed point and orientation for all floors in a building.12
Setup & Installation 13Chapter 24/3/03 Accton Draft—CONFIDENTIALSpecify host information, if necessary.The Aruba 50 uses the default host name aruba-master to find the host Aruba WLAN Switch. This assumes that your DNS has been configured to resolve aruba-master to the master Aruba WLAN Switch IP address.zIf you are not using DNS, you must manually configure the Aruba 50 with the IP address of the master Aruba WLAN Switch:apboot> setenv serverip <switch IP address>zIf you are using DNS but wish to specify a different host name, use the following com-mands:apboot> setenv master <switch host name>apboot> setenv serverip <switch host name>Save the configuration and reboot the Aruba 50.apboot> saveapboot> bootOnce the Aruba 50 boots, disconnect it and mount it in its intended service location (see instructions on page 14).34
4/3/03 Accton Draft—CONFIDENTIAL14 Aruba 50 Part 0500007AInstallation Guide May 2003Mount the Aruba 50When initial setup is complete, mount the Aruba 50 in its intended service location.Select a location as close as possible to the center of the intended coverage area. If necessary, use the Aruba WLAN Switch’s built-in site survey software to determine the optimum loca-tions for your access points and air monitors (see your Aruba AirOS Software Guide).The service location should be free from obstructions or obvious sources of interference. Nor-mally, the higher you place an access point or air monitor, the better its performance.The Aruba 50 can be mounted in the following ways:FIGURE 2-2  Aruba 50 Mounting OptionsFlat on a table or shelf (with the LEDs on top) either free-standing or using the included mounting kitUpright on a wall (with the port connectors on top) using the included mounting kitSuspended from above (with the LEDs on bottom) using the included mounting kit123CAUTION—For safety purposes, do not mount the Aruba 50 sideways (with the air vents on top and bottom).
Setup & Installation 15Chapter 24/3/03 Accton Draft—CONFIDENTIALFree-Standing PlacementTo place the Aruba 50 on a flat table or shelf, first attach the included non-skid foot-pads to the bottom of the chassis.Using the Mounting KitUse the included mounting kit to attach the Aruba 50 to a wall, shelf, or ceiling.NOTE—Do not attach the rubber foot-pads to the Aruba 50 when using the mounting kit.Attach the mounting cradle to a solid mounting surface.Place the flat side of the cradle against the mounting surface. If attaching the cradle to a wall, orient it so that the cable tie anchors are positioned at the top. If attaching the cradle to a table, shelf, or ceiling, orient the cable tie anchors toward the cable route.CAUTION—Do not place the Aruba 50 in any place where it could fall on people or equipment. For more secure installation, use the included mounting kit.1
4/3/03 Accton Draft—CONFIDENTIAL16 Aruba 50 Part 0500007AInstallation Guide May 2003Use the four included #6 screws (or equivalent) to secure the mounting cradle. If attaching the cradle to drywall, we recommend using appropriate wall anchors (not included) as show in Figure 2-3:FIGURE 2-3  Attaching the Mounting Cradle
Setup & Installation 17Chapter 24/3/03 Accton Draft—CONFIDENTIALPlace the Aruba 50 into the mounting cradle as shown in Figure 2-4.FIGURE 2-4  Placing the Aruba 50 into the CradleAlign the front edge of the chassis with the etched line on the mounting cradle. This will fit the Aruba 50 mounting slots over the matching cradle posts.Press and hold the Aruba 50 chassis against the retaining clips on the cradle.Slide the Aruba 50 into place. When properly positioned, the retaining clips will spring up to hold the chassis firmly in place.NOTE—To remove the Aruba 50 from the cradle, press down on both retaining clips and slide the chassis free of the mounting posts.Secure the Aruba 50, if desired.To prevent the unauthorized removal of the Aruba 50 from its installed location, use a Kens-ington MicroSaver Security Cable (not included). Wrap the security cable around an immov-able object, insert the cable’s lock into the Kensington Security Slot on the back of the Aruba 50, and turn the key.Orient the antennas.For best performance, swivel the antennas so that they are oriented vertically (see Figure 2-2 on page 14).Once mounting is complete, connect the required cables (see instructions on page 18).2ABC34
4/3/03 Accton Draft—CONFIDENTIAL18 Aruba 50 Part 0500007AInstallation Guide May 2003Connect Required CablesThe cables required for operating the Aruba 50 depend on your intended network topology (see Figure 2-1 on page 8) and on the physical location.Direct SPOE to the Aruba WLAN SwitchUse this procedure when connecting the Aruba 50 directly to an SPOE-compatible network port on the Aruba WLAN Switch (see “Power Over Ethernet” on page 2). SPOE provides 10/100 Mbps Ethernet, serial connection, and power over one cable.NOTE—If connecting the Aruba 50 through the LAN or to a non-SPOE network port on the Aruba WLAN Switch, see the instructions on page 19.Connect the included SPOE adapter to the Aruba 50.Connect the adapter’s 9-pin serial connector to the Console port on the back of the Aruba 50.Connect the adapter’s male RJ-45 plug to the FE port on the back of the Aruba 50.Connect the Aruba 50 to the Aruba WLAN Switch.The connection between the Aruba 50 and the Aruba WLAN Switch requires an 8-conduc-tor, Category 5 UTP, straight-through FE cable with RJ-45 connectors (see Appendix B for port specifications).Any FE cable installed in an air-handling space, as described in NEC (2002) Article 300.22(C), should be suitable under NEC Article 800.50 and marked accordingly for use in plenums and air-handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP or CMP. Install cables in accordance with all applicable local regulations and practices.Connect one end of the FE cable directly to the RJ-45 socket on the SPOE adapter that was attached to the Aruba 50 in the previous step.Connect the other end of the FE cable directly to an available SPOE network port on the Aruba WLAN Switch.NOTE—The Aruba 50 must be connected to the Aruba WLAN Switch without any inter-vening hubs, routers, or other networking equipment.1AB2AB
Setup & Installation 19Chapter 24/3/03 Accton Draft—CONFIDENTIALLAN or POE ConnectionUse this procedure when connecting the Aruba 50 through the LAN or to a non-SPOE net-work port on theAruba WLAN Switch.NOTE—If connecting the Aruba 50 directly to a SPOE network port on the Aruba WLAN Switch, see the instructions on page 18.Connect the Aruba 50 to the network.Connect one end of an FE cable to a network hub, router, or switch that has a routable path to the Aruba WLAN Switch.zIf the connecting device supports POE (see “Power Over Ethernet” on page 2), use an 8- or 4-conductor, Category 5 UTP, straight-through FE cable.zIf the connecting device does not support POE, use a 4- or 8-conductor, Category 5 UTP, straight-through or crossover FE cable.Any FE cable installed in an air-handling space, as described in NEC (2002) Article 300.22(C), should be suitable under NEC Article 800.50 and marked for use in plenums and air-handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP or CMP. Install cables in accordance with all applicable local regulations and practices.For port and cable details, see Appendix B.Connect the other end of the FE cable to the FE port on the back of the Aruba 50.Connect power.The Aruba 50 can receive electrical power using the following options:zPOE–If connecting the Aruba 50 to a device that supplies IEEE 802.3af compliant POE (see “Power Over Ethernet” on page 2), no additional power connection is necessary.zPower OutletNOTE—When the Aruba 50 is installed in an air-handling space, as described in NEC (2002) Article 300.22(C), POE must be used instead of a power outlet.If local regulations and practices permit, connect the included AC power adapter cable to the DC power socket on the rear panel of the Aruba 50 and plug it into an appropriate power outlet.CAUTION—Use only the AC power adapter supplied with this device. Other-wise, the product may be damaged.1AB2
4/3/03 Accton Draft—CONFIDENTIAL20 Aruba 50 Part 0500007AInstallation Guide May 2003
Troubleshooting 21Appendix A4/1/03 Accton Draft—CONFIDENTIALAPPENDIX ATroubleshooting*Information Pending
4/1/03 Accton Draft—CONFIDENTIAL22 Aruba 50 Part 0500007AInstallation Guide May 2003
Port Specifications 23Appendix B4/1/03 Accton Draft—CONFIDENTIALAPPENDIX BPort SpecificationsConsole PortThe console port is located on the back of the Aruba 50 and has a DB-9 female connector. Port pin-outs are shown in Figure B-1:Figure B-1  Aruba 50 Console PortCommunication settings for the console port are specified in Table B-1 :Tab l e B - 1  Console Terminal SettingsBaud Rate Data Bits Parity Stop Bits Flow Control9600 8 None 1 NoneAruba 50ConsoleDB-9 FemaleDCE Pin-Out
4/1/03 Accton Draft—CONFIDENTIAL24 Aruba 50 Part 0500007AInstallation Guide May 2003FE PortThe 10/100 Mbps Ethernet (FE) port is located on the back of the Aruba 50 and has an RJ-45 female connector. Port pin-outs are shown in Figure B-2:Figure B-2  Aruba 50 FE PortThe port accepts a 4- or 8-conductor Category 5 UTP FE cable with an RJ-45 male connector.The FE port detects MDI/MDX and automatically adjusts for straight-through or crossover cables. However, if Power Over Ethernet (POE) is used, a straight-through cable is required.The maximum length for FE cables is 100 meters (325 feet).When the Aruba 50 is installed in an air-handling space, as described in NEC (2002) Article 300.22(C), POE is required. Also, any FE cable installed in such spaces should be suitable under NEC Article 800.50 and marked accordingly for use in plenums and air-handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP or CMP.Install cables in accordance with all applicable local regulations and practices.
Port Specifications 25Appendix B4/1/03 Accton Draft—CONFIDENTIALSPOE AdapterThe Serial & Power Over Ethernet (SPOE) adapter pin-outs are shown in Figure B-3:Figure B-3  Aruba SPOE AdapterThe adapter requires an 8-conductor Category 5 UTP, straight-through FE cable with RJ-45 male connectors. The cable must connect the SPOE adapter to an FE+SPOE port on the Aruba WLAN Switch, with no intervening hubs, routers, or other network equipment.The maximum length for FE cables is 100 meters (325 feet).The Aruba 50 and SPOE adapter are plenum rated. When is installed in an air-handling space, as described in NEC (2002) Article 300.22(C), the connecting FE cable should be suitable under NEC Article 800.50 and marked accordingly for use in plenums and air-handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP or CMP.Install cables in accordance with all applicable local regulations and practices.
4/1/03 Accton Draft—CONFIDENTIAL26 Aruba 50 Part 0500007AInstallation Guide May 2003
Product Specifications 27Appendix C4/1/03 Accton Draft—CONFIDENTIALAPPENDIX CProduct SpecificationsThe following specifications apply to the Aruba 50 Wireless Access Point (model WAP-50).PhysicalEnvironmentTABLE C-1 Physical SpecificationsItem MeasurementSize 20.5 x 13.6 x 4 cm(8.07 x 5.35 x 1.58 in)Weight 280 gram (9.9 oz.)TABLE C-2 Environmental SpecificationsItem MeasurementTemperature Operating: 0 to 50 ºC (32 to 122 ºF)Storage: 0 to 70 ºC (32 to 158 ºF)Humidity 5% to 95% (non-condensing)
4/1/03 Accton Draft—CONFIDENTIAL28 Aruba 50 Part 0500007AInstallation Guide May 2003OperationGeneralTABLE C-3 Operational SpecificationsItem MeasurementMaximum Channels 802.11a—US & Canada: 13, Japan: 5802.11b—US & Canada: 1-11, Europe: 1-13, France: 10-13,Japan: 1-14, Spain: 10-11Maximum Clients 64Operating Range 802.11a—Up to 503 m (1650 ft.)802.11b—Up to 396 m (1300 ft.)Data Rate 802.11a—6, 9, 12, 18, 24, 36, 48, 54 Mbps per channel802.11b—1, 2, 5.5, 11 Mbps per channelOperating Frequency 802.11a—5.15 ~ 5.25 GHz (lower band) US/Canada, Japan5.25 ~ 5.35 GHz (middle band) US/Canada5.725 ~ 5.825 GHz (upper band) US/Canada802.11b—2.412 ~ 2.452 GHz US/Canada, Japan2.457 ~ 2.462 GHz US/Canada, Europe, France, Japan, Spain2.467 ~ 2.472 GHz Europe, France, Japan2.484 GHz JapanOutput Power 16 dBm minimumPower Adapter Input—100-240 AC, 50-60 HzAccess Point Input—3.3 VDC, 3 A (AC adapter), or48 VDC, 150 mA (POE)LED Indicators Ready (Power), LAN (Ethernet Link/Activity), .A and .B (Access Point/Air Monitor Mode)Standards IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX,IEEE 802.11a/b, IEEE 802.3af802.11b—2.412 ~ 2.452 GHz US/Canada, Japan2.457 ~ 2.462 GHz US/Canada, Europe, France, Japan, Spain2.467 ~ 2.472 GHz Europe, France, Japan2.484 GHz Japan15. IEEE 802.3af
Product Specifications 29Appendix C4/1/03 Accton Draft—CONFIDENTIALMaximum DistanceMaximum distances posted below are the actual tested distance thresholds. However, there are many variables such as barrier composition and construction and local environmental interfer-ence that may impact your actual distances and cause you to experience distance thresholds far lower than those we post below:An Outdoor Environment is a line-of-sight environment with no interference or obstruction between the access point and clients.An Indoor Environment is a typical office or home environment with floor to ceiling obstruc-tions between the access point and clients.TABLE C-4 IEEE 802.11a Maximum DistancesSpeed (Mbps)Condition544836241812 9 6OutdoorEnvironment40 m (132 ft.)221 m (726 ft.)251 m (825 ft.)322 m (1056 ft.)350 m (1155 ft.)382 m (1254 ft.)453 m (1485 ft.)503 m (1650 ft.)IndoorEnvironment18 m (60 ft.)25 m (82 ft.)30 m (99 ft.)35 m (115 ft.)40 m (132 ft.)45 m (149 ft.)48 m (157 ft.)50 m (165 ft.)TABLE C-5 IEEE 802.11b Maximum DistancesSpeed (Mbps)Condition 11 5.5 2 1OutdoorEnvironment152 m(500 ft.)233 m(766 ft.)315 m(1033 ft.)396 m(1300 ft.)IndoorEnvironment23 m(75 ft.)30 m(100 ft.)61 m(200 ft.)61 m(200 ft.)IEEE 802.11b Maximum Distances152 m(500 ft.)233 m(766 ft.)315 m(1033 ft.)396 m(1300 ft.)Speed (Mbps)115.52123 m(75 ft.)30 m(100 ft.)61 m(200 ft.)61 m(200 ft.)An Outdoor Environment is a line-of-sight environment with no interference or obstructionbetween the access point and clients.An Indoor Environment is a typical office or home environment with floor to ceiling obstructions between the access point and clients.
4/1/03 Accton Draft—CONFIDENTIAL30 Aruba 50 Part 0500007AInstallation Guide May 2003Sensitivity and ModulationTABLE C-6 IEEE 802.11a Sensitivity and ModulationModulation/Rates Sensitivity(dBm)5.15-5.25GHZ(dBm)5.25-5.35GHZ(dBm)BPSK (6 Mbps) -85 16 20BPSK (9 Mbps) -84 16 20QPSK (12 Mbps) -83 16 19QPSK (18 Mbps) -81 16 1916 QAM (24 Mbps) -78 16 1816 QAM (36 Mbps) -74 16 1864 QAM (48 Mbps) -69 16 1664 QAM(54 Mbps) -65 14 14TABLE C-7 IEEE 802.11b Sensitivity and ModulationModulation/Rates Sensitivity(dBm)2.412-2.484GHZ(dBm)DBPSK (1 Mbps) -86 20DQPSK (2 Mbps) -85 17PBCC (5.5 Mbps) -85 15CCK (5.5 Mbps) -81 13PBCC (11 Mbps) -83 7CCK (11 Mbps) -81 0IEEE 802.11b Sensitivity and Modulation2.412-2.484GHZDBPSK (1 Mbps) -86 20DQPSK (2 Mbps)PBCC (5.5 Mbps)CCK (5.5 Mbps)PBCC (11 Mbps)CCK (11 Mbps)-86-85-85-81-83-812017151370C-5
Product Specifications 31Appendix C4/1/03 Accton Draft—CONFIDENTIALCertificationsTABLE C-8 CertificationsItem MeasurementElectromagneticCompatibilityFCC Part 15 Class B, FCC Part 15 Class C 15.207/15.247,FCC Part 15 Class E 15.407ICES-003,RSS 210 (CAN)IEC 61000-4-2/3/4/6/11EN 55022, EN55024 (89/336/EEC),ETS 300 328 (89/336/EEC), ETS 301 489 (89/336/EEC),ETS 301 893AS/NZS 3548,RFS 29 (NZ)Safety CSA/NTRL (CSA 22.2 No. 950 & UL 1950)EN60950 (TÜV/GS), IEC60950 (CB), UL 2043C-6