Acer orporated AM100 Air Monitor User Manual AM100 User s Manual

Acer Incorporated Air Monitor AM100 User s Manual

Contents

Users Manual

   AM100 Air Monitor    Indoor Air Quality Monitor
Chapter of Contents  I  Copyright   The documentation and the software included with this product are copyrighted 2017 by Acer Incorporated. All rights are reserved. Acer Incorporated. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Acer Incorporated. Information provided in this manual is intended to be accurate and reliable. However, Acer Incorporated. assumes no responsibility for its use, nor for any infringements of the rights of third parties, which may result from its use.    Declaration of Conformity   FCC Class B Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.  Warning! Any changes or modifications made to the equipment which are not expressly approved by the relevant standards authority could void your authority to operate the equipment.   Caution! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dis-pose of used batteries according to the manufacturer’s instructions.
II  Chapter  of  Contents       Packing List Before you begin installing AM100, please make sure that the following materials have been shipped:   AM100   Accessories for AM100 -  Warranty card -  Safety card -  Quick Guide -  USB Cable -  USB Adaptor -  Mounting screws If any of these items are missing or damaged, contact your distributor or sales representative immediately.   Technical Support and Assistance   1.  Visit the Acer web site at www.acer.com/support where you can find the latest information about the product.    2.  Contact your distributor, sales representative, or Acer's customer service center for technical support if you need additional assistance. Please have the following information ready before you call:   -  Product name and serial number   -  Description of your peripheral attachments   -  Description of your software (operating system, version, application software, etc.)   -  A complete description of the problem   -  The exact wording of any error messages         Warning! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equiv- alert type recommended by the manufacturer. Dispose of used batteries, according to the manufacturer's instructions.
Chapter of Contents  III   Warning! 1.  Use 3.75V Li-ion rechargeable battery. 2.  Packing: please carry the unit with both hands, handle with care 3.  Maintenance: to properly maintain and clean the surfaces, use only approved products or clean with a dry applicator  Safety Instructions   1.  Read these safety instructions carefully. 2.  Keep this User Manual for later reference. 3.  Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4.  For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5.  Keep this equipment away from humidity. 6.  Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage. 7.  The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS. 8.  Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. 9.  Position the power cord so that people cannot step on it. Do not place anything over the power cord. 10.  All cautions and warnings on the equipment should be noted. 11.  If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. 12.  Never pour any liquid into an opening. This may cause fire or electrical shock. 13.  Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel. 14.  If one of the following situations arises, get the equipment checked by service personnel: 15.  The power cord or plug is damaged. 16.  Liquid has penetrated into the equipment. 17.  The equipment has been exposed to moisture. 18.  The equipment does not work well, or you cannot get it to work according to the user's manual. 19.  The equipment has been dropped and damaged. 20.  The equipment has obvious signs of breakage. 21.  DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -25° C    OR ABOVE 50° C. THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT.
IV  Chapter  of  Contents       22.  CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER, DISCARD USED   BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. DISCLAIMER: This set of instructions is given according to IEC 704-1. Acer disclaims all responsibility for the accuracy of any statements contained herein.
Chapter of Contents  V     Table of Contents CHAPTER 1 GENERAL INFORMATION ......................................... 1 1.1 INTRODUCTION ..........................................................................................1 1.2 GENERAL SPECIFICATION ...........................................................................1 1.2.1 General ......................................................................................................................... 1 1.3 DIMENSIONS .............................................................................................2 1.4 POWER SPECIFICATION ..............................................................................2 CHAPTER 2 GENERAL SPECIFICATION ...................................... 3 2.1 AM100 AIR MONITOR SPECIFICATION .........................................................3 2.2 LED & KEY INFORMATION ..........................................................................4 2.2.1 WiFi LED ....................................................................................................................... 4 2.2.2 Power LED .................................................................................................................... 5 2.2.3 Function Key ................................................................................................................. 5 CHAPTER 3 INSTALLATION AND DOWNLOAD APP ................... 6 3.1 INSTALLATION ............................................................................................6 3.2 DOWNLOAD THE APPS ................................................................................7
VI  Chapter  of  Contents       List of Figures Figure 1-1   Dimensions of AM100 ........................................................................................ 2 Figure 2-1   WiFi LED Position .............................................................................................. 4 Figure 2-2   Power LED Position ........................................................................................... 5 Figure 2-3   Function Key Position ......................................................................................... 5 Figure 3-1   Desk standalone or wall-mount AM100 .............................................................. 6 Figure 3-2   Power On and color light .................................................................................... 6 Figure 3-3   QR Code for App ................................................................................................ 7   List of Tables Table 2-1 AM100 Product Specification ................................................................................. 3
General Information  1  Chapter 1  General Information This chapter gives background information on the AM100. Sections include:   Introduction   General Specifications   Dimensions  1.1  Introduction The AM100 is an indoor air quality monitor that able to detect PM2.5/PM10, Co2, TVOC, Temperature, Humidity, and Lighting of your environment, it’s able to connect with Acer AOP cloud for long-term AQI records and provide pre-caution message of the air quality surrounds you.  1.2  General Specification 1.2.1 General  Dimensions (W x H x D): 100 mm (L) x 100 mm (H) x 43.7 mm (D)  Weight: 240 kg  Power supply: ADAPTER 100-240VAC in, 5V /1A DC out
2  General Information     1.3  Dimensions Figure 1-1   Dimensions of AM100    1.4  Power Specification  AC Characteristics:   -  AC Input 100 ~ 240V 0.2A Max., 50 ~ 60Hz  Output Type: Micro-USB  Output Voltage: 5V, 1A Max  Vendor Model: DSA-5PFU1-05
General Specification  3  Chapter 2  General Specification This chapter details system setup on the AM100  2.1  AM100 Air Monitor Specification  Table 2-1  AM100 Product Specification Processor BROADCOM 20737S ARM Cortex-M3 Memory Embedded 512Kb EEPROM 60Kb RAM Power Voltage range/frequency: 100 ~ 240V AC, 50/60 Hz DC Output: 5V/1A Battery Build-in Rechargeable/non-Replaceable Lithium-ion Polymer Battery Connectivity Bluetooth Bluetooth 4.0 LE Wireless LAN Wi-Fi 802.11 b/g/n   Sensors Particulate Matter PM2.5/PM10 (μg/m³) Experimental estimation from Sensor output  Detectable Particle size > 0.7μ m PM2.5 Range: 0 - 500 μg/m³ ;Resolution: 1.0 μg/m³ PM10 Range: 0-1000 ug/m3; Resolution: 1.0 ug/m3 TVOC Detect Total concentration of Volatile Organic Compounds:   Alcohols, Aldehydes, Aliphatic Hydrocarbons, Amines, Aromatic hydrocarbons, CO, CH4, LPG, Ketones, Organic acids, etc.  Range: 125 - 3500 PPB Resolution: 1.0 PPB IAQ-CO2 indicator Conversion from tVOC (Range: 450-10000 ppm, Resolution: 1 PPM Temperature Range: -20℃ to 80℃, Resolution: 0.1 ℃ Humidity Relative Humidity %; Range: 0 - 100%, Resolution: 1.0% Ambient Light Sensor Yes Multimedia Buzzer Yes Temperature Operating 5℃ ~40℃ Storage -25℃ ~50℃ Shipping -25℃ ~50℃ Humidity Operating 0%~85%
4  General Specification      2.2  LED & Key Information 2.2.1 WiFi LED Figure 2-1   WiFi LED Position   Blank – No Connection Red – Connect to WiFi AP Green – Connect to Acer AOP
General Specification  5  2.2.2 Power LED Figure 2-2   Power LED Position   Blank – Power cable disconnect Red – Charging Green – 100% charged  2.2.3 Function Key Figure 2-3   Function Key Position   Press 2 sec. – Instant detect air quality Press 3 sec. – Clean WiFi AP setting Press 5 sec. – Clean BT setting
Installation and Download App  6   Chapter 3  Installation and Download App This chapter details installing the AM100 Installation and Download App Sections include:   Installation   App Download  3.1  Installation Connect the AM100 with USB power cable. Adding micro-USB L sharp transfer socket for desk standalone or without it for wall-mount.  Figure 3-1   Desk standalone or wall-mount AM100     Power on the device and the air quality color light will show.  Figure 3-2   Power On and color light
7  Installation and Download App   3.2  Download the apps You can download the apps for both Android and iOS  Scan the QR code  Figure 3-3   QR Code for App

Navigation menu