Aclara Power Line Systems Y72160-301 Wireless Meter Reading System User Manual RF
Aclara Power-Line Systems Inc. Wireless Meter Reading System RF
Users Manual
DRAFT TWACS - ORION FOR CENTRON METER USER GUIDE Y10426-TUM DRAFT Proprietary Notice Information contained in this document is private to Distribution Control Systems, Inc., St. Louis, Missouri (DCSI). This information may not be published, reproduced, or otherwise disseminated without the express written authorization of DCSI. Any software or firmware described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by DCSI. DCSI assumes no responsibility for any errors that may appear in this document. Changes not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. DRAFT No responsibility is assumed for the use or reliability of software on equipment that is not supplied by DCSI. TWACS, the TWACS logo, and the DCSI logo are registered trademarks of Distribution Control Systems, Inc., St. Louis, Mo. All other registered trademarks are property of their respective owners. TWACS® Two-Way Automatic Communication System, a product of Distribution Control Systems, Inc. Confidential and Proprietary Copyright 2006 All Rights Reserved TWACS® - ORION® for CENTRON® Meter User Guide (Y10426-TUM) DRAFT Table of Contents Figures and Tables iii Using this Manual Purpose . . . . . . . Warnings . . . . . . . Icon Definitions . . . . Related Documentation Support . . . . . . . Let Us Know How We’re . . . . . . . . . . . . . . . Doing Chapter 1: Installation and Operation DRAFT System Overview . . . . . . . . . . . . . . . . Theory of Operation . . . . . . . . . . . . . . . Electric Meter Transceiver (EMTR-2) . . . . . . . Badger Meter, Inc. ORION® Transmitter . . . . . Hand Held Transceiver - Low Power (HHTR-LP) . . Navigating the HHTR-LP Screens . . . . . . . HHTR-LP Menus . . . . . . . . . . . . . . . RF Hardware Installation. . . . . . . . . . . . . Pre-Installation Field Survey . . . . . . . . . . Environmental Conditions . . . . . . . . . . Installing a New EMTR-2 Module . . . . . . . . . ORION Equipment Installation . . . . . . . . . . ORION Equipment Replacement . . . . . . . . . Installing a Replacement EMTR-2 Module . . . . . Replace the Remt List In the EMTR-2. . . . . . . ORION and EMTR-2 Communication Setup . . . . . Install the ORION (Linking the ORION and EMTR-2) Confirm ORION Installation . . . . . . . . . . No ORION Data Received During the Install . . . Delete the ORION from the Remt List . . . . . . Chapter 2: Testing, Troubleshooting, and Maintenance Troubleshooting and Error Messages. TNS Troubleshooting . . . . . . . Field Troubleshooting. . . . . . . Configuration/Installation Status HHTR-LP Displayed Error Codes . Meter Shop Test System . . . . . . Maintenance . . . . . . . . . . . Warranty . . . . . . . . . . . . . Return Procedures. . . . . . . . . Chapter 3: Specifications .6 .7 .8 .9 10 11 11 13 13 13 15 16 16 16 16 20 20 22 22 23 27 28 28 28 29 32 34 35 35 35 37 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 38 Electrical Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Compliance Specifications . . . . . . . . . . . . . . . . . . . . . . . 38 TWACS® - ORION® for CENTRON® Meter User Guide Table of Contents Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . 39 Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 39 41 Glossary 45 Index 53 DRAFT Acronyms ii TWACS® - ORION® for CENTRON® Meter User Guide Figures and Tables Electric Meter Transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 ORION transmitters for water, gas, and remote . . . . . . . . . . . . . . 9 ORION transmitter specifications. . . . . . . . . . . . . . . . . . . . . . . . 9 Hand Held Transceiver keypad functions. . . . . . . . . . . . . . . . . . 10 Error Code Description and Solution. . . . . . . . . . . . . . . . . . . . . 32 Return address label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Electrical ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Compliance specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Environmental specifications . . . . . . . . . . . . . . . . . . . . . . . . . 39 Physical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Labeling requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 DRAFT Figure 1.1 Figure 1.2 Table 1.1 Figure 1.3 Table 2.1 Figure 2.1 Table 3.1 Table 3.2 Table 3.3 Table 3.4 Table 3.5 TWACS® - ORION® for CENTRON® Meter User Guide iii DRAFT Figures and Tables iv TWACS® - ORION® for CENTRON® Meter User Guide USING THIS MANUAL DRAFT This section contains information that helps you understand and use this manual. TWACS® - ORION® for CENTRON® Meter User Guide Purpose Purpose This TWACS® - ORION ®for CENTRON® Meter User Guide contains theory of operation, pre-installation considerations, hardware installation procedures, and instructions for using an Hand Held Transceiver - Low Power (HHTR-LP) tool to establish the communication link between the ORION® and EMTR-2. DRAFT Warnings TWACS® - ORION® for CENTRON® Meter User Guide Using this Manual Icon Definitions Icon Definition HAZARD Indicates electrical equipment hazards and resulting death or serious injury from misuse. WARNING Indicates a potentially hazardous situation which - if precautions are not taken - could result in death or serious personal injury. DRAFT CAUTION Indicates a potentially hazardous situation which- if precautions are not taken - may result in minor or moderate injury. IMPORTANT Provides information that is important, but will not result in NOTE physical injury if not followed. Provides additional information or tips on the process. Related Documentation The following publications are referenced in this manual. The DCSI documents listed below plus the latest version of all other DCSI technical publications are available through the TWACS® Portal (https:// portal.twacs.com/). • Electronic Metering Transponder for CENTRON Meter User Guide (Y10317TM) • TNS End User Guide (Y10285TM) • Returned Merchandise Packing Requirement Service Advisory (Y10377TM) • Stationary RCE Test Unit Technical Manual (Y103018-1TM) • Portable RCE Test Unit Technical Manual (Y10327-3TM) • CENTRON Meter Technical Reference (RES-CEN-0025-08.02) • Pit ORION Installation Data (ORI-I-36) • Universal 1 Tranamitter Installation Data (ORI-I-39) • Recordall Transmitter Register Remote ORION 3-Wire Installation Data (ORI-I-35) • ORION Integral Transmitter for Gas Meters Installation and Operation Manual (ORI-IOM-39) • ORION Equipped Gas Meters Using the Badger-Radix Programming Tool Installation and Operation Manual (ORI-IOM-40) • ORION Programming Software Installation and Operation Manual (ORI-IOM-38) TWACS® - ORION® for CENTRON® Meter User Guide Support Support Please address your questions to Customer Care as follows: E-mail: care@twacs.com Phone: 1-800-892-9008 Address: Distribution Control Systems, Inc. 945 Hornet Drive Hazelwood, MO 63042 USA DRAFT Let Us Know How We’re Doing In an ongoing effort to produce effective documentation, the Technical Publications department at DCSI welcomes any feedback you can offer regarding this manual. Please relay feedback, including suggestions for improvement or to alert us to corrections, by sending an email to techpubs@twacs.com or calling Customer Care at 1-800-892-9008. TWACS® - ORION® for CENTRON® Meter User Guide CHAPTER CHAPTER 0 INSTALLATION AND OPERATION CHAPTER0 DRAFT This chapter provides a brief overview of the TWACS-ORION system, explains how the TWACS-ORION system interfaces with the TWACS system, and describes the functions of the EMTR-2, HHTR-LP, and ORION transmitter. It is useful for installers and personnel who would benefit from an overview of the entire system. TWACS® - ORION® for CENTRON® Meter User Guide System Overview System Overview The TWACS - ORION system utilizes radio frequency (RF) transmission communication between a RF-enabled auxiliary meter and a RF-enabled CENTRON meter. Data relative to energy usage from auxiliary gas, water, or another electric meter can be gathered and retrieved in this manner. The system provides selectable Total Consumption data and Present Consumption data based on the hourly interval meter reading. Information is retrieved across the Two-Way Automatic Communication System (TWACS) network by the TWACS Net Server (TNS) located at the utility company. DRAFT The TWACS - ORION system solution is comprised of the following RF devices: NOTE • Electric Meter Transceiver (EMTR-2) • Hand Held Transceiver - Low Power (HHTR-LP) • Electronic Metering Transponder (EMT-3C-MP) Also part of the system, but not provided or installed by DCSI, is the Badger Meter, Inc. ORION transmitter that is installed at the auxiliary meter and converts the meter information into electronic signals. RF communication links the ORION (located at the auxiliary meter) to the EMTR-2 (located inside a nearby electric meter.) This communication enables successful operation of the Automatic Meter Reading (AMR) system. AUXILIARY METER RF COMMUNICATION UP TO 400 FEET LINE-OF-SIGHT ORION TRANSMITTER ELECTRIC METER ELECTRIC METER TRANSCEIVER (EMTR) TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation Theory of Operation The DCSI TWACS® - ORION® system operates within the 916.450 MHz UHF radio frequency range on channel 43A. This unlicensed frequency band is known as the ISM (Industrial, Science, and Medical) band. All components in the DCSI TWACS® - ORION®system comply with FCC (Federal Communications Commission) rules and regulations for radio devices operating in this frequency range. DRAFT This band provides up to 79 channels; the TWACS® - ORION® system uses 51 of these channels. A channel is defined as a pair of adjacent frequencies used for transmission and for reception. Refer to the note below. Because the FCC limits the amount and duration of channel energy that can be emitted during RF transmission, the TWACS® - ORION® system employs transmission Frequency Shift Keying (FSK). This modulation and frequency hopping technology serves to: • Comply with FCC regulations • Reduce potential interference to and from other devices operating in the same band • Reduce the potential for eavesdropping • Minimize the effects of signal reduction NOTE Frequency hopping employs an algorithm that provides a half duplex (one transmission direction at a time [send or receive]), pseudo-random sequence of frequencies for the two-way radio link. Frequency Shift Keying modulation controls data transmission by “frequency shifting” between two frequencies (a channel). One frequency is used to represent the logical “1” and a different frequency represents the logical “0”. Five channels provide link acquisition with the HHTR-LP while the remaining 45 channels are used for data transmission after a successful link is established. The one remaining channel is used for TWACS-ORION communication. The EMTR-2 retains data until new data is uploaded during an ORION session. If an ORION transmitter is removed from the Remt List table stored in the EMTR-2, the previously loaded data (for the removed ORION transmitter) is automatically deleted. TWACS® - ORION® for CENTRON® Meter User Guide Theory of Operation Electric Meter Transceiver (EMTR-2) The EMTR-2 is an electronic module assembly (EMA) that is installed in a TWACS-enabled CENTRON meter. The EMTR-2 is connected to the EMT-3C-MP transponder during meter/transponder integration. The EMTR-2 adds functionality to the host EMT-3C-MP. It does not communicate over the power line, but uploads the data to the EMT-3C-MP that has power line TWACS capabilities. DRAFT The EMTR-2 can communicate with up to four ORION transmitters. Data from the ORION transmitter is relayed to the EMA. This data is accessed by the TNS across the TWACS network. Near the top of the hour, the EMTR-2 listens (for 12.5 seconds) for communication from an ORION transmitter. Then, for 8.5 seconds the EMTR-2 listens for an HHTR-LP. This pattern cycles 35 times. No further communication occurs until the next top of the hour. The top of the hour is set in TNS. Refer to Metering Maintenance in the TNS User Guide for instructions. Figure 1.1 Electric Meter Transceiver TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation Badger Meter, Inc. ORION® Transmitter The DCSI RF TWACS System and the Badger Meter, Inc. ORION transmitter are capable of data communication. The ORION module uses the RF bubble-up broadcast mode to communicate (one way) from the auxiliary meter to the electric meter. The ORION transmitter sends customer usage data (at 100Kbps) every five seconds on the 916.450 MHz frequency channel. The RF TWACS system receives this data and transmits it to the EMTR-2. Then it is retrieved by the utility, across power distribution lines. Figure 1.2 ORION transmitters for water, gas, and remote GAS ORION DRAFT WATER ORION REMOTE ORION Specifications: Table 1.1 ORION transmitter specifications ORION Specification Description Power Functional Life Expectancy 3.6 VDC embedded battery Minimum: 10 years Expected: 15 years 916.450 MHz Burst mode fixed length packet, simplex 3-of-6 100 Kbps + 1 Kbps None Frequency Shift Keying (FSK) Non Return to Zero (NRZ) Single channel (43A) 400 ft. clear line of sight affected by installation and conditions; less if pit installed Frequency Data Communications Data Format Data Rate Data Encryption Modulation Packet Encoding Channels Range TWACS® - ORION® for CENTRON® Meter User Guide Theory of Operation Hand Held Transceiver - Low Power (HHTR-LP) The DCSI Hand Held Transceiver - Low Power (HHTR-LP) is used to configure and setup the EMTR-2 (installed in the electric meter). The HHTR-LP is also used to create the communication link between the EMTR-2 and the ORION transmitter and can be used to test the radio link. DRAFT Figure 1.3 Hand Held Transceiver keypad functions 10 TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation Navigating the HHTR-LP Screens Use the arrow buttons to navigate through the HHTR-LP screens. Table 1.2 HHTR-LP screen navigation buttons Button Number Graphic Function DRAFT NOTE Move left Move up Move right Move down When pressing the 7, 8, 9, or 0 numeric button, the HHTR-LP automatically determines whether the numeric or scroll functionality of the button is required. Adjust the display contrast by using the number 2 and 3 buttons as follows: • Increase the contrast - Hold down the Shift button and repeatedly press the number 2 button. • Decrease the contrast - Hold down the Shift button and repeatedly press the number 3 button. Esc button functionality: • Press once to end the current procedure and return to the previous menu. • Repeatedly press to “back out” to previous menus. HHTR-LP Menus The following list describes the menus and selections available from the HHTR-LP. Main Menu Item Order - Main menu selection. • New/Go - Presents screens that allow entry of an order number. Remote - Main menu selection. • Orion - Top-level Orion menu. • Install (See page 20). TWACS® - ORION® for CENTRON® Meter User Guide 11 Theory of Operation • Com Stat - Presents configuration status screens (See page 29).This status information is read from the EMTR-2. • RMTR - RMTR menu. Not used in the TWACS-ORION System. EMTR - Main menu selection. • Status - Presents EMTR-2 status data screens. • Replace - Presents screens that enable replacement of the EMTR-2 (See page 16). • Delete - Presents screens that enable removal of the ORION from the Remt List (See page 16). • Remt List - Displays list of linked ORION transmitters. DRAFT Serial Com - Not used. 12 TWACS - Main menu selection. • HRTS - Enables configuration of meter auxiliary ports. • TWACS Modem - Not used. HHTR Config - Main menu selection. • Setup - Presents screens that enable selection of HHTR-LP options. • Status - Not used. • Power - Presents screens that enable selection of Power options. • Diags - Presents screens that enable selection of Diagnostic options. TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation RF Hardware Installation This section provides instructions for installing the RF hardware onsite. A functioning network can be created and its functionality verified before leaving the site. Pre-Installation Field Survey DRAFT The field survey is used to review the environmental conditions present at any particular location and lay out the system to maximize performance. DCSI recommends that you conduct a field survey before performing the actual hardware installation. As with all RF devices, certain environmental conditions must be present to optimize RF communications. Be aware of the factors that affect the radio transmission between the ORION and the EMTR-2 when performing the field survey, such as: • Metal objects • Thick walls or foliage • Local radio interference • Position of the ORION and/or EMTR-2 Factor in all environmental conditions when planning the location of the meter/EMTR-2 assembly. NOTE A clear line of sight between the ORION transmitter and receiver is preferred, but is not always attainable. The following section discusses the environmental conditions that may affect RF transmissions between the ORION and EMTR-2. Environmental Conditions Optimal RF communication between the ORION and the EMTR-2 is affected by many environmental conditions. Vehicular traffic, parked vehicles in the signal path, weather conditions, construction, and even the growth of foliage may affect or degrade RF communication. Gradual loss of communication from the ORION (caused by an aging battery for example) can be detected through system checks by the TWACS Net Server (TNS) Master Station. Persistent loss of communication may indicate environmental interference and require a site visit to determine the cause. NOTE Sites that continue to experience persistent loss of communication may require a wired solution to ensure reliable operation. TWACS® - ORION® for CENTRON® Meter User Guide 13 RF Hardware Installation The following environmental factors or conditions may affect RF transmission between the ORION unit and the EMTR-2 located at the electric meter. • Metal Objects Metal objects significantly reduce the strength of the signals reaching the receiver. Ensure that no metal cladding, cabling, mirrors, water tanks, refrigerators, pipes, etc. are near the ORION or EMTR-2. The straight-line path between both units should be as unobstructed as possible. NOTE A small, single item, such as a pipe situated half-way between the transmitter and receiver, is less likely to have any affect on the signal strength than a larger item(s). DRAFT • Thick walls or foliage NOTE Thick walls or foliage between the transmitter and receiver can reduce the signal strength. Brick, aluminum siding, thick stone walls, and concrete can impede signal reception. Avoid dense foliage between the RF units and, when possible, provide a reserve “growth” clearance to accommodate the growth of foliage on bushes and trees during spring and summer. Radio signals can pass more easily through plasterboard walls, fiberglass, and wood paneling than the previously listed materials. • Local radio interference The close proximity of a cell phone mast, a taxi operator's base station, or large electrical equipment may provide strong radio interference. The AMR radio devices should be relocated if these interferences are present. • Position of the ORION and/or EMTR-2 These are important factors in RF deployment. The ORION antenna is omni-directional. The signal radiates 360 degrees. The EMTR-2 antenna alignment is parallel to the front cover of the electric meter, and is the most sensitive RF reception surface. Face the front of the meter/EMTR-2 toward the ORION transmitter when possible; even on opposite sides of a building. This allows maximum communication surface and distance between the units. Allow for some additional power margin in the signal strength to accommodate seasonal or other changes in environmental conditions. In the future, after installation, the site owner should inform you of any alterations to the site that could affect radio performance. 14 TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation Installing a New EMTR-2 Module This procedure installs an EMTR-2 module by installing an RF-equipped CENTRON meter. Technicians must install this equipment in accordance with all National and Local Code provisions. WARNING WARNING - EXPLOSIVE HAZARD - Substitution of components may impair suitability for Class I, Division 2. DRAFT CAUTION Wear all safety equipment according to your utility rules before opening the meter base: hard hats, safety face shield, fire retardant clothing, high voltage rated gloves, safety rated shoes. WARNING Any work on or near energized meters, meter sockets, or other metering equipment can present a danger of electrical shock. Such shock could cause serious injury or death. To field install a new EMTR-2-equipped CENTRON meter, refer to the Electronic Metering Transponder for CENTRON Meter User Guide (Y10317TM). To complete the installation process, the meter must be configured into the TNS (refer to the TNS End User Guide for directions). In order to complete this next step in the installation process, record the location of the meter by collecting the following information: • • • • • • • TWACS Serial number (required) Substation (required) Bus Feeder Phase Detection Signal The TNS operator uses this location information to search for the meter. The more pieces of location information available, the less time TNS will take to search for the meter. Refer to the TNS End User Guide for data retrieval instructions. TWACS® - ORION® for CENTRON® Meter User Guide 15 RF Hardware Installation ORION Equipment Installation Follow the Badger Meter, Inc.equipment installation instructions to install the ORION transmitter. Installers must install the ORION equipment in accordance with all National and Local Code provisions. ORION Equipment Replacement Follow the Badger Meter, Inc.equipment instructions to remove and replace an existing ORION transmitter. Installers must perform these procedures in accordance with all National and Local Code provisions. DRAFT Installing a Replacement EMTR-2 Module NOTE This procedure is the same as installing a new EMTR-2-equipped meter. Previous usage data must be retrieved and ORION/EMTR-2 linkage information must be reassigned to the replacement EMTR-2. 1. Refer to Installing a New EMTR-2 Module on page 15 for installation instructions. 2. Refer to ORION and EMTR-2 Communication Setup on page 20 for linkage assignment instructions. Refer to the TNS End User Guide for data retrieval instructions. Replace the Remt List In the EMTR-2 This procedure downloads the Remt List from the existing EMTR-2 to the HHTR-LP so the Remt List can be uploaded to the replacement EMTR-2. Two important conditions apply to this procedure: 1. NOTE If communication is not possible, this procedure can not be performed. Replace the existing meter according to your utility procedures, and perform Install the ORION (Linking the ORION and EMTR-2) on page 20 to install the individual ORION transmitters. 2. 16 The existing EMTR-2 must be able to communicate with the ORION for the Remt List to be downloaded to the HHTR-LP to simplify reinstalling applicable ORIONs. This procedure requires the physical removal of the existing installed meter and installation of a replacement meter/EMTR-2 combination. TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation Perform the following procedure to replace an EMTR-2. If you pressed the HHTR-LP On/Off button at the end of any previous procedure, begin with step 1. -ORIf you pressed the Esc button, begin with step 2. 1. Press the On/Off button on the HHTR-LP. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR DRAFT 2. Press the down arrow button to position the cursor in front of the REMOTE option. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR 3. Press the down arrow button to position the cursor in front of the EMTR option. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR 4. Press the Enter button. The EMTR menu appears. EMTR Menu Select Replace Delete Status Remt. List 5. Press the Enter button. The following screen appears. EMTR: Replacement Select: Read Old EMTR Write New EMTR 6. Press the Enter button. The following screen appears. TWACS® - ORION® for CENTRON® Meter User Guide 17 RF Hardware Installation EMTR: Replacement Verify Order # XXXXX ESC: No, Enter: Yes 7. Enter an Order number if different from that displayed and press Enter to Accept. The following screen appears. DRAFT EMTR: Replacement Enter Serial Number Old S/N: _________ Enter To Accept 8. Press the Enter button. The following two screens appear. EMTR: Replacement EMTR S/N 1234567890 Receiving Remote Lst, EMTR: Replacement EMTR S/N 1234567890 Success! NOTE At this point in the procedure, the technician must replace the “old” utility meter with a replacement integrated meter/EMTR-2 combination. Refer to Installing a New EMTR-2 Module on page 15. 9. Press the Esc button once and the following screen appears. EMTR: Replacement Select: Read Old EMTR Write New EMTR 10. Press the Enter button. The Order Number screen appears. EMTR: Replacement Verify Order # XXXXX ESC: No, Enter: Yes 11. 18 Enter the order number and press the Enter button. The following screen appears. TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation EMTR: Replacement Enter Serial Number New S/N: ___________ Enter To Accept 12. Press the Enter button. The following two screens appear. EMTR: Replacement DRAFT Verifying New EMTR, Please Wait... EMTR: Replacement EMTR S/N 1234567890 Success! 13. Press the Esc button three times to return to the Main Menu screen. -ORPress the On/Off button. TWACS® - ORION® for CENTRON® Meter User Guide 19 ORION and EMTR-2 Communication Setup ORION and EMTR-2 Communication Setup This section describes the steps required to use the HHTR-LP to configure, link, and remove/replace an ORION or EMTR-2. RF equipment setup procedures consist of configuring the EMTR-2 and making the RF communication link between the ORION and EMTR-2. You may also view the communication statistics (Refer to Field Troubleshooting on page 28), or test the link between the ORION and EMTR-2 by reading the Total Consumption register for the applicable port and verifying the reading on the auxiliary meter dials. Install the ORION (Linking the ORION and EMTR-2) Complete the following steps to link the ORION to a nearby EMTR-2. DRAFT 1. Press the On/Off button on the HHTR-LP. The “flash” screen appears momentarily displaying the software version number. Firmware Vn.n is replaced with the firmware version number installed in your HHTR-LP. DCSI: HHTR-LP Y72160-301 Firmware Vn.n Www.twacs.com The Main Menu screen appears. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR 2. Press the down arrow once to position the arrow cursor in front of the REMOTE option. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR 3. Press the Enter button. Remote Menu Select: ORION 4. 20 Press the Enter button to accept the default selection. TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation Orion Menu Select: Install Com Stat 5. Press the Enter button to accept Install. Orion Install Menu Enter Serial Number Orion S/N 123456 Enter To Accept DRAFT 6. NOTE Enter the ORION serial number in the spaces provided, if it is not automatically entered for you. The EMTR recognizes only 6-digit numbers. ORION serial numbers (from BadgerMeter, Inc.) may have more than 6 numbers in the serial number. Enter only the last 6 digits of the serial number or the EMTR will NOT recognize the ORION transmitter. 7. Press the Enter button. Orion Install Menu Select: Water Nat Gas Propane Electric 8. Press the Enter button. Orion Install Menu Enter Serial Number EMTR S/N 123456 Enter To Accept 9. Press the Enter button. Orion Install Menu EMTR S/N 123456 Orion S/N 123456 EMTR checking tables Orion Install Menu EMTR S/N 123456 Orion S/N 123456 EMTR writing tables TWACS® - ORION® for CENTRON® Meter User Guide 21 ORION and EMTR-2 Communication Setup Orion Install Menu EMTR S/N 123456 Orion S/N 123456 EMTR trying Orn. Acq. DRAFT Orion Install Menu EMTR S/N 123456 Orion S/N 123456 EMTR checking EnrTbl NOTE Orion Install Menu EMTR S/N 123456 Orion S/N 123456 Success! 10. Press any key and the following screen displays. Orion Install Menu Success! Reading: 01234567890 RSSI: 255 11. Press the Esc button to return to the ORION Menu. If you receive a message from the Error Codes list, press the Esc button, then repeat steps 5-9. Refer to HHTR-LP Displayed Error Codes on page 32 for error code description and resolution. Your previously selected options will appear on the screens when you repeat steps 5-9. Make new selections or entries, or press the Enter button to accept each correct entry. Confirm ORION Installation You may confirm that the ORION transmitter was successfully installed by performing a Remote List query. No ORION Data Received During the Install If you receive the following message after step 9. of the Install procedure... Orion Install Menu EMTR S/N 123456 Orion S/N 123456 SSI=0 Esc:OK Ent:Rpt 22 TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation 12. Press the Enter button to recheck. The EMTR-2 attempts to reacquire the ORION signal. If the EMTR-2 is successful, the “success” screen shown in step 9 displays. 13. Press the ESC button and the following two screens display. Orion Install Menu EMTR S/N 123456 Orion S/N 123456 Warn: No Orion Data DRAFT Orion Install Menu Warn: No Orion Data Reading: 0 RSSI: 0 14. Press the ESC button to return to the ORION Menu Refer to Troubleshooting and Error Messages on page 28. Delete the ORION from the Remt List If your ORION and EMTR-2 are not communicating, or if you need to replace a malfunctioning ORION module, this procedure provides the instructions to delete the ORION from the Remt List stored in the EMTR-2. Complete the following steps to delete the ORION from the EMTR-2. 1. Press the On/Off button on the HHTR-LP. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR 2. Press the down arrow button twice to position the cursor in front of the EMTR option. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR 3. Press the Enter button. EMTR Menu Select Status Delete Remt List Replace TWACS® - ORION® for CENTRON® Meter User Guide 23 ORION and EMTR-2 Communication Setup Use the arrow buttons to select Delete. 5. Press the Enter button. The Remote Menu appears. 4. Remote Menu Select: ORION 6. Press the Enter button. DRAFT EMTR: Delete Orion Enter Serial Number EMTR S/N:_______ Enter To Accept 7. Enter the serial number of the EMTR-2 in the EMTR-2 S/N field, if it is not automatically entered for you. 8. Press the Enter button. EMTR: Delete Orion Enter Serial Number Orn. S/N:_______ Enter To Accept 9. Enter the Orion serial number in the Orn. S/N field, if it is not automatically entered for you. 10. Press Enter to accept. The following two screens display briefly. EMTR: Delete Orion EMTR S/N 123456 Orion S/N 123456 Receiving Remote List EMTR: Delete Orion EMTR S/N 123456 Orion S/N 123456 Found Orion, Del’ing The Success! screen displays, indicating that the ORION has been successfully removed from the Remt List table stored in the EMTR-2. 24 TWACS® - ORION® for CENTRON® Meter User Guide Installation and Operation EMTR: Delete Orion EMTR S/N 123456 Success! Press the Esc button twice to return to the Main Menu screen. DRAFT 11. TWACS® - ORION® for CENTRON® Meter User Guide 25 DRAFT ORION and EMTR-2 Communication Setup 26 TWACS® - ORION® for CENTRON® Meter User Guide CHAPTER TESTING, TROUBLESHOOTING, AND MAINTENANCE DRAFT This chapter explains how to test and manage typical TWACS-ORION system problems. It is useful for installers and meter shop personnel. TWACS® - ORION® for CENTRON® Meter User Guide 27 Troubleshooting and Error Messages Troubleshooting and Error Messages The following troubleshooting information can be used to determine the cause of improper operation of the TWACS-ORION system. TNS Troubleshooting The TNS system can be used to check module and meter communication. The TNS system includes error flags in returned messages that aid in issue identification. For error codes, refer to the Troubleshooting chapter in the TNS End User Guide. DRAFT For information about TNS Trouble Server Applications, refer to the Trouble Server Applications in the TNS End User Guide. Field Troubleshooting Distribution Control Systems, Inc. has developed various software and hardware products for testing TWACS-enabled devices in the field and the meter shop. See the Meter Shop Test System section of this chapter for information regarding use of this system. The EMTR-2 has no field serviceable parts. It can only install, delete, or query installed ORION transmitters. When necessary, the HHTR can be used to • Install the Orion transmitter (HHTR can not communicate with Orion) • Query the EMTR for a remote installed list • Delete Orion from the EMTR installed list • Check EMTR status (Hardware & Firmware version, and RCE Type & Model) A remote list query by the HHTR gives port-specific information for each installed Orion transmitter as follows: • Serial Number • Present Total Consumption (not current total consumption, but rather last RF communication total consumption, usually < 1 hr old) • Leak Detect (tripped by water meter, will reset on its own, or can be manually reset in the field; see the meter manufacturer documentation for trip and reset conditions) • Tamper Detect (must be field reset at water meter) • RSSI (snapshot-from last check in) • Acquisition Failures 28 TWACS® - ORION® for CENTRON® Meter User Guide Chapter 2 • Testing, Troubleshooting, and Maintenance • 24 Hr Acq Log If there is a problem, the applicable error code is displayed. For RF communication, and HHTR-LP or user error codes, refer to HHTR-LP Displayed Error Codes. Configuration/Installation Status You can view additional information about configuration and link status by selecting Com Stat from the ORION Menu screen. Although this information is read from the EMTR-2, check the RF Link Data: Acq Log (refer to step 16. of this procedure) to verify recent successful ORION/EMTR communication. Complete the following steps to view configuration and link status data. DRAFT 1. Press the On/Off button on the HHTR-LP. The “flash” screen appears momentarily displaying the software version number. Firmware Vn.n is replaced with the firmware version number installed in your HHTR-LP. DCSI: HHTR-LP Y72160-301 Firmware Vn.n Www.twacs.com The Main Menu screen appears. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR 2. Press the down arrow once to position the arrow cursor in front of the REMOTE option. Main Menu Order Serial Com REMOTE TWACS HHTR Config EMTR 3. Press the Enter button. Remote Menu Select: ORION 4. Press the Enter button to accept the ORION default selection. TWACS® - ORION® for CENTRON® Meter User Guide 29 Troubleshooting and Error Messages Orion Menu Select: Install Com Stat 5. Press the down arrow once to position the arrow cursor in front of the Com Stat option. Orion Menu Select: Install Com Stat DRAFT 6. Press the Enter button. Orion Com Status Enter the Serial #, Orn S/N:_______ Enter To Accept 7. Enter the ORION serial number in the spaces provided. 8. Press the Enter button. Orion Com Status Enter the Serial #, EMTR S/N:_______ Enter To Accept 9. Enter the EMTR-2 serial number in the spaces provided. 10. Press the Enter button. The following two screens appear. Orion Com Status Collecting data from EMTR. Please Wait... Orion Com Status EMTR S/N _________ Orion S/N _________ Success! 11. Press the down arrow or the Enter button. The following status screen appears. 30 TWACS® - ORION® for CENTRON® Meter User Guide Chapter 2 • Testing, Troubleshooting, and Maintenance Orion Com Status Reading: 1234567890 Battery: N/A N/V Memory: N/A • Reading: displays the number on the ORION. A correct number (0000000000-9999999999) here verifies proper equipment operation. Press the down arrow or the Enter button. 12. DRAFT Orion Com Status Meter Com: N/A Hist MTR Com: N/A LeakDet: N Tamper: N • Ignore Meter Com. • Ignore the Hist MTR Com entry for installation purposes. • LeakDet options are Y or N (Water only). If Y, a site visit is required to locate the leak. Clear error and reset the meter onsite after correcting the leak. Leak detect trips at the meter if total consumption is continuously incremented. After no continuous consumption for a period of time (determined by the meter manufacturer) the meter will automatically reset. • Tamper options are Y or N. Clear error and reset the meter onsite after correcting tamper source. Press the down arrow or the Enter button. 13. Orion Com Status RF Link Data: PA: N/A RSSI: 123 Link: N/A • RSSI (Received Signal Strength Indicator) displays the received signal strength. The range is 0-255 with 255 being the highest strength. 14. Press the down arrow or the Enter button Orion Com Status RF Link Data: Last Ch: N/A Acq Failures: 0 Ignore this screen for installation purposes. TWACS® - ORION® for CENTRON® Meter User Guide 31 Troubleshooting and Error Messages 15. Press the down arrow or the Enter button Orion Com Status RF Link Data: Lnk Abandonment: N/A Error Code: N/A Ignore this screen for installation purposes. 16. Press the down arrow or the Enter button DRAFT Orion Com Status RF Link Data: 24 Hr Acq Log:00000000 00000000 00000000 The Acq Log displays 24 bits (in three groups of eight) representing the hourly check-in for the last 24 hours. A one (1) indicates that the hourly check-in was successful and a zero (0) indicates that it was not. The least significant bit (bottom right) indicates the past hour check-in status. Each hour the bits are shifted one position to the left. In the example below, the ORION successfully checked in the past hour, but did not for each of the previous three hours. Acq Log: 11111111 11111101 11110001 17. Press the On/Off button to turn the HHTR-LP Off. HHTR-LP Displayed Error Codes Table 2.1 Error The following table lists the error code number and error message text that the HHTR-LP displays when the specific error is encountered while using the HHTR-LP to communicate with the TWACS-ORION system. Error Code Description and Solution Description The following error codes are RF communication errors. 01 RF Error General error. 02 Service Not Supported Service is not supported. 03 Not used 04 Operation Not Possible RF error. 05 Inappropriate Action RF error. Requested 06 RF Device Busy RF error. 07 Data From Device Not RF error. (Usually memory) Ready 31 RF Device Sent NAK RF error 32 Solution Retry the command. Retry the command. Retry the command. Retry the command. Retry the command. Retry the command. Retry the command. TWACS® - ORION® for CENTRON® Meter User Guide Chapter 2 • Testing, Troubleshooting, and Maintenance Table 2.1 Error Code Description and Solution Error Description DRAFT 32 Can not acquire an RF Link RF error 33 Operation Timed Out Operation time expired without success. The following error codes are internal HHTR-LP or user errors. 101 RF PIC sends a NAK The RFPIC isn't ready or doesn't understand the command. The RF PIC internal to the HHTR-LP has failed. 102 RF PIC is busy RFPIC is performing another operation and is currently busy. The RF PIC internal to the HHTR-LP was in the middle of another command. 103 No response from RF PIC The RFPIC isn't responding to the on HHTR-LP UI. No Response from the RF PIC. The RF PIC didn't respond to the UI processor. 104 RF PIC send invalid The RFPIC sent an invalid response response to the UI. The HHTR-LP UI processor didn't recognize the response from the RF PIC. 105 Operation canceled Indicates the Esc button was pressed during an operation. 106 ORION-EMTR session The HHTR-LP timed out waiting failed for the RMTR to respond back to the HHTR-LP.The HHTR-LP was unable to link to the requested EMTR-2. 107 No Space Available in The EMTR is at capacity. It can EMTR. The Table is Full. not accept additional Remotess. 112 EMTR already has Remotes assigned 113 The New EMTR can not accept xx Number of Remotes. 114 An order needs to be created first. Use the order menu Can not program a new EMTR with the data from an old EMTR because the new EMTR already has Remotes assigned. Can not program a new EMTR with the data from an old EMTR because the new EMTR can not store as many Remote as the old EMTR. When replacing an EMTR, the HHTR-LP needs to store the Remt list. An “order number” needs to be assigned so that the HHTR-LP has a location to store the list. TWACS® - ORION® for CENTRON® Meter User Guide Solution Retry the command. Retry the command. Retry the command. Retry the command. Retry the command. Retry the command. The user aborted the last command. Verify the serial number and retry the command. A Remote must be removed before adding another. Remove all Remotes from the new EMTR first. Select “order” from the main menu, select “new” and enter a number. 33 Meter Shop Test System Table 2.1 Error Code Description and Solution Error Description 208 ORION S/N Already exists in the EMTR Table. Can not install the selected ORION because it is already installed. Can not remove the ORION nor perform a Com Status because that ORION is not installed to the selected EMTR. This service in the EMTR is at capacity. It can not accept additional Orions. 209 The Selected ORION is NOT in the EMTR Table. DRAFT 211 Service is Full, Can not add ORION to the EMTR List. 215 The Selected Remt. is NOT an Orion. Solution Check serial number and try again. An ORION must be removed from this service before adding another. If you are unable to resolve a problem with the TWACS-ORION system, return the meter to your integrator or DCSI. See Return Procedures. Refer to the Electronic Metering Transponder for CENTRON Meter User Guide (Y10317TM) Rev. A for transponder-related troubleshooting information. Refer to the CENTRON Meter Technical Reference Guide for additional meter information. Meter Shop Test System Use the Meter Shop Test System to test TWACS signaling, read select transponder registers, zero select transponder registers, and perform various other transponder functions on a TWACS-enabled CENTRON meter. For complete details on the Meter Shop Test System, see the Meter Shop Test System Help (accessed by clicking the Help button on the Meter Shop Test Tool main menu) or contact your Program Manager or DCSI Customer Care at care@twacs.com or 1-800-892-9008. Because of the various test equipments available for use with DCSI products and the configuration requirements/options, the Meter Shop Test System Set-Up Guide (Y10030TM), will guide you through initial equipment selection and setup for meter/module testing. This user guide contains all the module-specific information necessary to test the RF TWACS-ORION System installed in the CENTRON meter. EMT-3C module TWACS serial number and meter-specific information is available on the meter label. Refer to Figure 2.1. Additional information, such as module Type and Model, can be found in Chapter 1 of this user guide. If you are unable to resolve a problem with the TWACS-ORION System, return the meter to your integrator or DCSI. See Return Proceduresbelow. 34 TWACS® - ORION® for CENTRON® Meter User Guide Chapter 2 • Testing, Troubleshooting, and Maintenance Maintenance The TWACS-ORION system requires no maintenance. Warranty Refer to contract terms for warranty information. DRAFT Return Procedures DCSI equipment which has been integrated or retrofitted by a third party, must be returned to the third party. Please do not return third party integrated equipment to DCSI. Contact the third party to obtain their “Return Authorization Number” and shipping instructions and return the equipment directly to the integrator/retrofitter. If you are a DCSI certified integrator and the product cannot be repaired in the meter shop, remove the module and complete the following procedure. NOTE Before returning an item to DCSI, refer to your contract terms for warranty information. If an item is out of warranty, a diagnostic fee may apply. Please send an email to rma@twacs.com for a diagnostic estimate. If you have any questions regarding returns, send an email to rma@twacs.com. 1. Send an email to rma@twacs.com with the information listed below. Within 24 hours, excluding weekends and holidays, you will receive an email acknowledging receipt of your request. After DCSI processes your request, you will receive a Return Material Authorization (RMA) number with the shipping instructions. To expedite the process, be sure to include all the information requested below: • Company name [Distributor name and location (city and state) if applicable] • Ship To name and address • Contact name, phone number, and email address • DCSI part number of each item • Serial number of each item • Description of each item • Total quantity (by DCSI part number) for each item • Specific reason for return of each item • Manufacturer number (number starting with A/M/V/C/W) of each RCE item 2. Once you receive an RMA number, package the IMT-XM according to the shipping instructions received and following the notes below. TWACS® - ORION® for CENTRON® Meter User Guide 35 Return Procedures IMPORTANT Items should be properly packaged to avoid shipping/handling damage during transit. Items must be packaged in individual anti-static or static dissipative bags and packed in sturdy, appropriately sized commercial boxes with packing material (styrofoam peanuts, bubblewrap, paper, etc.) arranged to prevent movement; in single layers; with the appropriate packaging between layers. Original packaging with dividers should be retained, reused, and re-identified if possible. IMPORTANT Items not packaged in accordance with DCSI packing requirements will not be accepted and will be returned freight collect. Please refer to the Returned Merchandise Packing Requirement Service Advisory (Y10377TM) for DCSI approved methods and materials. Contact DCSI Customer Care at care@twacs.com to receive a copy of this service advisory. DRAFT 3. 36 Mark the outside of the shipping container with the RMA number on the address label as shown in the following example. Figure 2.1 Return address label Upon shipment, send an email to rma@twacs.com with the shipping information (Carrier Name, Waybill/Pro/Tracking Number, and Date item left your facility) so DCSI can track the shipment. TWACS® - ORION® for CENTRON® Meter User Guide CHAPTER SPECIFICATIONS DRAFT This chapter contains electrical, environmental, and physical specifications for the EMTR-2 and HHTR-LP. TWACS® - ORION® for CENTRON® Meter User Guide 37 Electrical Specifications Electrical Specifications The electrical specifications include: • Electrical ratings • Compliance Specifications Electrical Ratings The following table provides the electrical ratings. Electrical ratings DRAFT Table 3.1 Parameter Rating Voltage Quiescent power Maximum input surge Internal fusing Grounding Electronics connection 6V<=V<=12V 25mA approximate 100mA maximum None None The EMTR-2 is connected to the EMT-3C-MP transponder during meter/transponder integration. Electronics isolation Refer to the Electronic Metering Transponder for CENTRON Meter User Guide Y10317TM. Compliance Specifications NOTE The following table provides the compliance specifications. ANSI C12.1-2001 is the referring standard for tests listed in tables 5.2, 5.3, and 5.4. Table 3.2 Compliance specifications Test Title Applicable Specification EMI/RFI Emission conducted/radiated ANSI C12.1-2001 Test No. 27- “Radio Frequency Conducted and Radiated Emissions” per CFR 47 Part 15, Class A and B. (See also ANSI C63.4) ANSI C12.1-2001 Test No. 26- “Effect of Radio Frequency Interference” ANSI C12.1-2001/IEEE C62.41-1991 Test No. 17- “Effect of High Voltage Line Surges” ANSI C12.1-2001 Test No. 25- “Electrical Fast Transient/Burst” (Testing at 100 and 400 KHz is required) IEC 801-4: 1988 ANSI/IEEE C.37.90.1 - 2002 EMI/RFI Susceptibility AC line surge Electrical fast transient Surge withstand capability FT and OSC 38 TWACS® - ORION® for CENTRON® Meter User Guide Chapter 3 • Specifications Table 3.2 Compliance specifications Test Title Applicable Specification High voltage isolation on meter chassis Voltage interruption test ANSI C12.1-2001 Test No. 15- “Insulation” Effect of electrostatic discharge Effect of Variation of Frequency Effect of Variation of Voltage on the Metering Device DRAFT NOTE ANSI C12.1-2001 Test No. 16- “Voltage Interruption” ANSI C12.1-2001 Test No. 28- “Effect of Electric Discharge (ESD)” ANSI C12.1-2001. Test #6 ANSI C12.1-2001. Test #5. Per Measurement Canada, Specifications/Standards LMG-EG-07 & PS-E-09-E are used to verify compliance with Canadian criteria. Environmental Specifications The following table provides the environmental specifications. Table 3.3 Environmental specifications Thermal Effect of operating temperature Per ANSI C12.1-2001 Test No. 30 Humidity Effect of relative humidity, both operational and storage Per ANSI C12.1-2001 Test No. 31 Physical Specifications The following table provides the physical specifications. Table 3.4 Physical specifications Parameter Specification Size, weight, form factor Integrated dimensions Installation instructions Meter-specific Provided with shipping package. One per TWACS-enabled meter carton. Compliance Testing Specifications Mechanical tests • • • • Mechanical Shock Mechanical Vibration Transportation Drop Test Transportation Vibration Per relevant sections of ANSI C12.1 - 2001 described below: • • • • Test #32, per IEC 60068 part 2-27 Test #34, per IEC 60068 part 2-6 Test #33, per ISTA Test Procedure 1A Test #35, per ISTA Test Procedure 1A TWACS® - ORION® for CENTRON® Meter User Guide 39 Physical Specifications Table 3.4 Physical specifications Parameter Specification Physical Tamper Protection Meter seal Supported Table 3.5 Labeling requirements Labeling Requirements and Serial Number DRAFT HHTR-LP Labeling per ANSI C12.10-1987 for: 40 • • • • DCSI/customer name DCSI/customer logo TWACS serial number Barcode TWACS® - ORION® for CENTRON® Meter User Guide Acronyms Asynchronous Data Link Control AMR Automatic Meter Reading AP Alternate Pathmaps ASCII American Standard Code for Information Interchange BPA Backplane Assembly CCA Card Cage Assembly CCE Central Control Equipment CIS Customer Information System DRAFT ADLC CLI Command Line Interface CMT Commercial Meter Transponder CPSA CRU Power Supply Assembly CRA Correlation Receiver Assembly CRMA Correlation Receiver Multiplexer Assembly CRPA Correlation Receiver Processor Assembly CRU Control and Receiving Unit CT Current Transformer DCPA Direct Current Power Assembly DCSI Distribution Control Systems, Inc. DP Diagnostic Pending DPA Distribution Panel Assembly DS Diagnostic Set DSI Disconnect Switch Interbase EMA Electronic Metering Assembly EMTR Electronic Meter Transceiver EOM End of Message FEP Front-End Processor FCC Federal Communication Commission FSK Frequency Shift Keying GUI Graphical User Interface HHTR-LP Hand Held Transceiver - Low Power IC Incomplete IMT/CMT Data ILS Integrated Load Survey TWACS® - ORION® for CENTRON® Meter User Guide 41 Acronyms Inbound Multiplexer Assembly IMT Integrated Metering Transponder IP In Progress IPU Inbound Pickup Unit ISM Industrial, Science, and Medical KWH Kilowatt Hours LCT Load Control Transponder LS Load Survey MIT Meter Interface Transponder MS Master Station MSFE Master Station Field Equipment DRAFT IMA MTU Modulation Transformer Unit NA Invalid Data NS Register Not Supported ODBC Open Database Connectivity OFIA Outbound Fiber Optics Interface Assembly OK Successful Read OMU Outbound Modulation Unit OPA Outbound Processor Assembly PD Partial Data PE Pending PR Pending Retry QC Quality Code RC Reasonability Check Failed RCE Remote Communications Equipment RF Radio Frequency RI Reset In Progress RL Register Length Invalid RM Read Meter RMTR Remote Meter Transceiver RO Retry Override RPA Receiver Processor Assembly RSSI Received Signal Strength Indicator SCADA Supervisory Control and Data Acquisition SCE Substation Communications Equipment 42 TWACS® - ORION® for CENTRON® Meter User Guide Acronyms Substation Communications Processor Assembly SDC Service Disconnect/Connect SP Substation Status STS Substation Test Set TC Total Consumption TD Total Demand TNS TWACS Net Server TOU Time of Use TP Tamper Pending TS Tamper Set TWACS Two-Way Automatic Communication System DRAFT SCPA UHF Ultra High Frequency ZC Zero Crossing TWACS® - ORION® for CENTRON® Meter User Guide 43 DRAFT Acronyms 44 TWACS® - ORION® for CENTRON® Meter User Guide Glossary American National Standards Institute (ANSI) An independent, U.S.-based technical standards organization. AMR See Automatic Meter Reading. ANSI See American National Standards Institute. Automatic Meter Reading (AMR) DRAFT Electronic accumulation and transport of meter data. billing demand information Consists of the demand reset count, which increments, and the demand previous billing. billing read Defines the registers used during one-time scheduled reads and on-request reads. DSHTBill read (Daily Shift Billing) Defines the registers used during recurring scheduled reads; normally used to create billing files. blink count See power-down count. bus identification Identifies the substation bus to which DCSI’s equipment is connect. CCE See Central Control Equipment. Central Control Equipment (CCE) The top level of the TWACS system hierarchy, also referred to as the Master Station. The CCE typically resides at the utility home office, providing system control and data storage for the TWACS system. CIS See Customer Information System. TWACS® - ORION® for CENTRON® Meter User Guide 45 Glossary CMT See Commercial Metering Transponder. Customer Information System (CIS) A computer database that utilities use to keep track of their customer information (name, address, phone, meter serial number). Often includes bill printing functionality. Commercial Metering Transponder (CMT) An electronic assembly integrated into a commercial application electric meter to add TWACS communications capability to the meter. Daylight Saving Time (DST) DRAFT Daylight Saving Time is the practice of turning the clock ahead in the Spring and back again in the Fall. delay The number of minutes after the interval has occurred before the SCE attempts to send a time sync command to the RCE. demand The rate at which power is delivered over a specified period of time; the rate of consumption. Demand is expressed in kilowatts. demand interval The specified interval of time on which a demand measurement is based. Intervals are commonly specified as 15, 30, and 60 minutes. demand meter A metering device that indicates or records demand, maximum demand, or both. detection point Identifies the specific conductor on which the inbound signal is detected. This point is identified as either A phase, B phase, C phase, or neutral. dial encoder A device that encodes or converts the position of metering dials (normally used in water meters) into an electrical signal for subsequent processing and transmission. DST See Daylight Saving Time 46 TWACS® - ORION® for CENTRON® Meter User Guide Electronic Metering Assembly (EMA) An electronic assembly integrated into an electric meter to add TWACS communications capability to the meter. Electronic Meter Transceiver (EMTR) An electronic communication device that transmits and receives using RF transmission. EMA See Electronic Metering Assembly. EMTR See Electronic Meter Transceiver. DRAFT Federal Communication Commission (FCC) The Federal Communications Commission (FCC) is an independent United States government agency, directly responsible to Congress, and is charged with regulating interstate and international communications by radio, television, wire, satellite and cable. Among its duties, the FCC is responsible for rating personal computers and other electronic equipment as either Class A or Class B. The ratings indicate how much radiation a particular device emits. feeder identification Identifies which feeders are connected to which bus(es). firing angle The place on the sine wave where the RTS places the TWACS signal. frequency shift keying A data transmission control method that modulates, i.e. “shifts” between two radio frequencies. hand held transceiver - Low Power (HHTR-LP) A control device used to set up, link, and establish communication between the EMTR and Badger components of the TWACS RF system. industrial, science, and medical (ISM) An unlicensed radio frequency band. interval A relatively short time period over which energy use data is recorded by the transponder. The interval may be set for 15, 30, or 60 minutes, depending on the transponder type. Interval data is recorded for each consecutive interval. TWACS® - ORION® for CENTRON® Meter User Guide 47 Glossary interval data A breakdown of consumption over specific intervals of time. ISM See Industrial, Science, and Medical. load profile Recording, storing, and analyzing consumption data over a period of time for a particular installation. master station See Central Control Equipment (CCE). DRAFT maximum demand The highest demand measured over a selected period of time, such as one month. Meter Integration and Meter Test (MIMT) A department within DCSI that reviews utility meter programming files and determines register programming requirements. MIMT See Meter Integration and Meter Test. nonvolatile memory A physical data storage area that maintains its content when the power is turned off. on-demand reads An unscheduled command to read a register. ORION Transmitter A one-way (simplex) radio frequency transmitter, manufactured by Badger Meter Inc., that allows retrieval of metering data from pit-set water, water, and gas meters. It periodically broadcasts a data packet. PCB See Printed Circuit Board. peak demand See maximim demand. 48 TWACS® - ORION® for CENTRON® Meter User Guide phase The current supply conductors, other than the neutral conductor of a polyphase circuit, that usually carry the designation A phase, B phase, C phase. power-down count A voltage interruption greater than 0.1 seconds that the module will count as a power outage and will increase the power-down count register by one. Sometimes referred to as blink count. previous billing demand The maximum kW, or demand, as recorded at the time of the last reset. This value is normally used for billing purposes. DRAFT previous interval demand The demand value stored in the meter that reflects the demand prior to the last reset. Printed Circuit Board (PCB) A thin plate on which electronic components are placed. pulser An electronic or magnetic device that generates electric pulses in a quantity that is proportional to the physical variable under measurement and which the pulses represent. rate class A rate class is a set of registers read for a particular class of customer with a particular meter model. It defines registers used for Billing and DSHTBill reads. RCE See Remote Communication Equipment. received signal strength indicator (RSSI) A value indicating the strength of the received radio frequency signal. registers Data storage locations on the transponder microprocessor that contain a variety of information that is retrievable by the master station. The type of data in registers includes consumption and demand data TWACS® - ORION® for CENTRON® Meter User Guide 49 Glossary Remote Communication Equipment (RCE) The base of the TWACS system hierarchy. RCEs consist of the DCSI family of transponder products. RCEs are located at customer sites and interface TWACS communication with various end devices such as meters, water heaters, and air conditioning units to enable automatic meter reading (AMR), load management, or other functions. Remote Test Set (RTS) A TWACS communications test device used at a remote site to communicate locally, using TWACS, to a transponder over the power line. Remote Meter Transceiver (RMTR) DRAFT An electronic communication device that transmits accumulated data using RF transmission. Not used with the TWACS-ORION System. Remote Acquisition List A list of Remote Meter Transceivers stored in the EMTR. RSSI See Received Signal Strength Indicator. RTS See Remote Test Set. SCE See Substation Communication Equipment. Serial Time Unit (STU) A 2.5 seconds interval of time and the unit of measure of DCSI’s Serial Time system. The intervals of time begin at 12:00 midnight on a cyclic 24-hour basis. Example: 1:00 a.m. would in serial time: signal mode Identifies the path combination used during outbound communications. This combination can be either line-to-ground or line-to-line. STU See Serial Time Unit 50 TWACS® - ORION® for CENTRON® Meter User Guide Substation Communications Equipment (SCE) The middle tier of the TWACS system hierarchy, consisting of all TWACS substation equipment (CRU, OMU, IPU, and MTU). The SCE transmits and receives data between CCE and RCE. time-of-use (TOU) A multiple tiered billing technique based on when the consumer uses the energy. TNS See TWACS Net Server. TOU DRAFT See time-of-use transponders Two-way field devices that can receive and send messages to and from the substation. TWACS See Two-Way Automatic Communication System. TWACS Net Server (TNS) Chief component of the entire Two-Way Automatic Communication System. Manages all collected metering and interval data as well as the connection between the utility and the consumer’s premises. Two-Way Automatic Communication System (TWACS) A patented technology that allows the utility to send and retrieve information to and from meters and other devices using the utility’s power lines as a communication network. Ultra High Frequency (UHF) A frequency range in the radio frequency spectrum between 300 MHz and 3.0 GHz. window The amount of time in minutes available after the delay has occurred for the SCE to send a date/time command. TWACS® - ORION® for CENTRON® Meter User Guide 51 DRAFT Glossary 52 TWACS® - ORION® for CENTRON® Meter User Guide Index acquisition list, Remt 12, 23, 24 acronyms 41 ANSI 45 labeling requirements 40 line of sight 6, 13 linking, ORION and EMTR 20 Badger Meter, Inc 6 maintenance 35 menus, HHTR EMTR 12 delete 12 Remt list 12 replace 12 status 12 HHTR Config 12 diags 12 power 12 setup 12 status 12 Remote 11 RMTR 12 TWACS 12 HRTS 12 TWACS modem care@twacs.com 4 communication 13 compliance specifications 38 current configuration 23 customer care 4 DRAFT Delete 23 electric meter transceiver 6, 8, 25 electrical ratings 38 electrical specifications 38 EMTR See electric meter transceiver environmental specifications 39 error codes 29 FCC Meter Shop Test System 34 ORION 16, 20, 31 ORION transmitter 9 Com Stat 12 Install 11 See federal communications commission federal communications commission 7 frequency hopping 7 frequency shift keying 7 FSK See frequency shift keying glossary 45 hand held transceiver 6, 10 keypad functions menus 11 physical specifications 39 purpose 7 radio frequency range 7 return material authorization (RMA) 35 return procedures 35 RF equipment installation environmental conditions 13 field installing a replacement EMTR module 10 16 HHTR See hand held transceiver industrial, science, and medical band 7 ISM band See industrial, science, and medical band 12 pre-installation field survey rma@twacs.com 35, 36 RSSI 31 13 safety equipment 15 specifications 37 compliance TWACS® - ORION® for CENTRON® Meter User Guide 38 53 Index electrical 38 environmental physical 39 39 Troubleshooting Field 32 TNG 28 TWACS - ORION system electric meter transceiver hand held transceiver 6 TWACS Net Server (TNS) 6 Two-Way Automatic Communication System (TWACS) 6 DRAFT warnings 2 warranty 35 54 TWACS® - ORION® for CENTRON® Meter User Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2006:06:09 07:45:51Z Creator Tool : FrameMaker 7.2 Modify Date : 2006:06:09 08:02:21-05:00 Metadata Date : 2006:06:09 08:02:21-05:00 Format : application/pdf Creator : bakers Title : RF.book Document ID : uuid:25dfc160-231b-434c-97e3-fdccbd9eae92 Instance ID : uuid:92d59574-4e5b-45e4-9ad2-95cd8a2f0385 Has XFA : No Page Count : 62 Author : bakersEXIF Metadata provided by EXIF.tools