Ademco 04007500 Microwave/PIR motion sensor User Manual

Honeywell International Inc. Microwave/PIR motion sensor Users Manual

a href="https://usermanual.wiki/Ademco" itemprop="url"> Ademco >

Users Manual

DT7500SN V-PlexTM DUAL TEC Motion Sensor  - Installation Instructions                              WTTV- V+OPEN / OUVERTURE / APERTURA / APERTURA / OPENLOCATION / EMPLACEMENT / POSIZIONAMENTO / LOCALIZACIÓN / LOCATION  MOUNT / INSTALLATION / MONTAGGIO / MONTAJE / MOUNT3Range AdjustmentRéglage de la portée hyper Regolazione della portata Ajuste del rango de detecciónRange Adjustment 52.1 - 2.4 m(7 - 8 ft)162WIRE / CABLAGE / COLLEGAMENTO / CABLEADO / WIREIDENTIFY COMPONENTS AND SELECT APPROPRIATE SETTINGS / IDENTIFICATION DES COMPOSANTS ET SÉLECTION DES PARAMÈTRES APPROPRIÉS / IDENTIFICARE I COMPONENTI E SELEZIONARE LE IMPOSTAZIONI APPROPRIATE / IDENTIFICAR LOS COMPONENTES Y SELECCIONAR LA CONFIGURACIÓN ADECUADA / IDENTIFY COMPONENTS AND SELECT APPROPRIATE SETTINGS1Polling Loop9 - 13VDCSMB-10TTAMPER24 VDC, 10mA0.3-1.3mm2(22-16 AWG)Cover Tamper SwitchContact AP du capot Interruttore tamper sul     coperchio Tamper de la cubierta Cover Tamper Switch32Rear Tamper Breakaway TabRear Tamper Breakaway TabRear Tamper Breakaway TabRear Tamper Breakaway TabRear Tamper Breakaway TabWWith SMB10T With SMB10T With SMB10T With SMB10T With SMB10T With SMB10T ONOFF1234525%50% 75%100%TT+-WONOFF12345Pulse Count 2Low SensitivityLED Disabled Microwave Walk Test OFFAnti-Mask OFFPulse Count 1High SensitivityLED EnabledMicrowave Walk Test ONAnti-Mask ONLEDREPLACE CIRCUIT BOARD / REMISE EN PLACE DU PCB / RIPOSIZIONARE IL CIRCUITO / VOLVER A COLOCAR LA PLACA DE CIRCUITO IMPRESO / REPLACE CIRCUIT BOARD4If installed with a Smart V-PlexTM Panel:The sensor will not transmit or indicate intrusion alarms when the panel is disarmed; in the armed state, the sensor will respond to all communications to or with the host panel.If installed with a Standard V-PlexTM Panel: The sensor will respond to all communications with the host panel armed or disarmed.ONOFF12345Pulse Count 2Low SensitivityLED Disabled Microwave Walk Test OFFAnti-Mask OFFPulse Count 1High SensitivityLED EnabledMicrowave Walk Test ONAnti-Mask ON<FR> If installed with a Smart V-PlexTM Panel:  The sensor will not transmit or indicate intrusion alarms when the panel is disarmed; in the armed state, the sensor will respond to all communications to or with the host panel.If installed with a Standard V-PlexTM Panel:   The sensor will respond to all communications with the host panel, armed or disarmed.Use these holes when mounting to a standard U.S. electrical junction boxONOFF12Lowest Sensitivity: 3 - 5 Steps; Up to 45 kg (100 lb) Pet ImmunityLowest Sensitivity: 3 - 5 Steps; Up to 45 kg (100 lb) Pet ImmunityLowest Sensitivity: 3 - 5 Steps; Up to 45 kg (100 lb) Pet ImmunityLowest Sensitivity: 3 - 5 Steps; Up to 45 kg (100 lb) Pet ImmunityLowest Sensitivity: 3 - 5 Steps; Up to 45 kg (100 lb) Pet ImmunityONOFF12Low Sensitivity: 2 - 4 Steps; Up to 23 kg (50 lb) Pet ImmunityLow Sensitivity: 2 - 4 Steps; Up to 23 kg (50 lb) Pet ImmunityLow Sensitivity: 2 - 4 Steps; Up to 23 kg (50 lb) Pet ImmunityLow Sensitivity: 2 - 4 Steps; Up to 23 kg (50 lb) Pet ImmunityLow Sensitivity: 2 - 4 Steps; Up to 23 kg (50 lb) Pet ImmunityONOFF12Medium Sensitivity: 1 - 3 Steps; No Pet ImmunityMedium Sensitivity: 1 - 3 Steps; No Pet ImmunityMedium Sensitivity: 1 - 3 Steps; No Pet ImmunityMedium Sensitivity: 1 - 3 Steps; No Pet ImmunityMedium Sensitivity: 1 - 3 Steps; No Pet ImmunityONOFF12High Sensitivity: 1 - 2 Steps; No Pet ImmunityHigh Sensitivity: 1 - 2 Steps; No Pet ImmunityHigh Sensitivity: 1 - 2 Steps; No Pet ImmunityHigh Sensitivity: 1 - 2 Steps; No Pet ImmunityHigh Sensitivity: 1 - 2 Steps; No Pet ImmunityLook-Down Mask (install as shown when using Pet Immune Lens)Look-Down Mask (install as shown when using Pet Immune Lens)Look-Down Mask (install as shown when using Pet Immune Lens)Look-Down Mask (install as shown when using Pet Immune Lens)Look-Down Mask (install as shown when using Pet Immune Lens)aONOFF12345Pulse Count 2Low SensitivityLED Disabled Microwave Walk Test OFFAnti-Mask OFFPulse Count 1High SensitivityLED EnabledMicrowave Walk Test ONAnti-Mask ON<IT> If installed with a Smart V-PlexTM Panel:  The sensor will not transmit or indicate intrusion alarms when the panel is disarmed; in the armed state, the sensor will respond to all communications to or with the host panel.If installed with a Standard V-PlexTM Panel:   The sensor will respond to all communications with the host panel, armed or disarmed.ONOFF12345Pulse Count 2Low SensitivityLED Disabled Microwave Walk Test OFFAnti-Mask OFFPulse Count 1High SensitivityLED EnabledMicrowave Walk Test ONAnti-Mask ON<ES> If installed with a Smart V-PlexTM Panel:  The sensor will not transmit or indicate intrusion alarms when the panel is disarmed; in the armed state, the sensor will respond to all communications to or with the host panel.If installed with a Standard V-PlexTM Panel:   The sensor will respond to all communications with the host panel, armed or disarmed.ONOFF12345Pulse Count 2Low SensitivityLED Disabled Microwave Walk Test OFFAnti-Mask OFFPulse Count 1High SensitivityLED EnabledMicrowave Walk Test ONAnti-Mask ON<PT> If installed with a Smart V-PlexTM Panel:  The sensor will not transmit or indicate intrusion alarms when the panel is disarmed; in the armed state, the sensor will respond to all communications to or with the host panel.If installed with a Standard V-PlexTM Panel:   The sensor will respond to all communications with the host panel, armed or disarmed.Wide Angle Lens (installed)Wide Angle Lens (installed)Wide Angle Lens (installed)Wide Angle Lens (installed)Wide Angle Lens (installed)Pet Immune Lens (included)Pet Immune Lens (included)Pet Immune Lens (included)Pet Immune Lens (included)Pet Immune Lens (included)
Download:
Mirror Download [FCC.gov]
Document ID992099
Application IDUb9/8CXbRee1Rofv6hQVcQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize125.52kB (1568945 bits)
Date Submitted2008-08-28 00:00:00
Date Available2008-08-28 00:00:00
Creation Date2008-05-28 13:17:35
Producing SoftwareAcrobat Distiller 4.05 for Windows
Document Lastmod2008-05-29 11:00:02
Document TitleUsers Manual
FCC ID Filing: C2D04007500

Navigation menu