Ademco 8DL5800FLOOD Wireless Water Leak Detector User Manual Users Manaul

Honeywell International Inc. Wireless Water Leak Detector Users Manaul

Users Manaul

Download: Ademco 8DL5800FLOOD Wireless Water Leak Detector User Manual Users Manaul
Mirror Download [FCC.gov]Ademco 8DL5800FLOOD Wireless Water Leak Detector User Manual Users Manaul
Document ID3674297
Application IDciWSJcTqIQaM/xweBQLeOw==
Document DescriptionUsers Manaul
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.86kB (348218 bits)
Date Submitted2017-12-12 00:00:00
Date Available2017-12-13 00:00:00
Creation Date2017-08-16 11:46:57
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2017-08-16 11:47:01
Document TitleUsers Manaul
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: Millien, Jean (S&FS)

5800FLOOD Flood Detector & Temperature Sensor
Instructions d’installation
INSTALLATION INSTRUCTIONS
The ADEMCO 5800FLOOD Flood Detector & Temperature
Sensor is a wireless transmitter used with Honeywell’s alarm
systems that support 5800 series devices. Applications include
bathrooms, laundry rooms, boilers and basements etc.
Ce contact de porte / fenêtre sans fil est conçu pour être
utilisé avec les panneaux de commande Honeywell qui
supportent les dispositifs de la série 5800. Applications
include bathrooms, laundry rooms, boilers and basements etc.
The 5800FLOOD:
• can serve as a hot and/or cold temperature sensor via
internal thermal sensor
(sends alarm to control when temperature is lower than
45°F (Cold condition) or above 95°F, (Hot condition).
• can serve as a Water leakage or Flood Detector via built-in
metal contacts on the bottom of the unit
(sends alarm to control within approximately 40 seconds
after water has come in contact with the metal probes.)
• does not require external probes
• functions (modes) set by programming pre-defined device
loop numbers (see table 1) to separate zones in the control
panel.
• provides tamper supervision, which sends a trouble signal
to the control if the unit’s cover is removed.
The 5800FLOOD:
INSTALLATION
INSTALLATION
Check Signal Strength: Before installing permanently,
conduct Go/No Go tests (see control's instructions) to
verify adequate signal strength from the planned location.
Adjust the device location as necessary.
Check Signal Strength: Before installing permanently,
conduct Go/No Go tests (see control's instructions) to
verify adequate signal strength from the planned location.
Adjust the device location as necessary.

• can serve as a hot and/or cold temperature sensor via
internal thermal sensor
(sends alarm to control when temperature is lower than
45°F (Cold condition) or above 95°F, (Hot condition).
• can serve as a Water leakage or Flood Detector via built-in
metal contacts on the bottom of the unit
(sends alarm to control within approximately 40 seconds
after water has come in contact with the metal probes.)
• does not require external probes
• functions (modes) set by programming pre-defined device
loop numbers (see table 1) to separate zones in the control
panel.
• provides tamper supervision, which sends a trouble signal
to the control if the unit’s cover is removed.

Water Leak Detection
Place the device on the floor or other desired location near any
area that potentially can be subject to a water leak condition
(ex. floor near or inside a kitchen cabinet, near the base of a
refrigerator, in a bathroom, basement, etc.).
Water Leak Detection
Place the device on the floor or other desired location near any
area that potentially can be subject to a water leak condition
(ex. floor near or inside a kitchen cabinet, near the base of a
refrigerator, in a bathroom, basement, etc.).
Make sure the metal contacts at the bottom of the enclosure
are clean and free of any debris before positioning the unit in
place.
Make sure the metal contacts at the bottom of the enclosure
are clean and free of any debris before positioning the unit in
place.
To ensure the unit remains in place, use the double-sided tape
to adhere unit to the floor or other surface.
To ensure the unit remains in place, use the double-sided tape
to adhere unit to the floor or other surface.
IMPORTANT: After a water leak detection event, make sure the
contacts and the unit are completely dry and free of any debris
before relocating the device.
IMPORTANT: After a water leak detection event, make sure the
contacts and the unit are completely dry and free of any debris
before relocating the device.
Temperature Sensing
Mount the device low on a wall in the desired location with
double-sided adhesive tape (supplied).
Temperature Sensing
Mount the device low on a wall in the desired location with
double-sided adhesive tape (supplied).
If used solely as a temperature sensor, the 5800FLOOD can
be mounted low on a wall with double-sided adhesive tape
(supplied).
If used solely as a temperature sensor, the 5800FLOOD can
be mounted low on a wall with double-sided adhesive tape
(supplied).
IMPORTANT:
• Do not install this device on or near metal objects, Avoid
locating the device near wiring such as AC, telephone, HVAC,
computer data cables, etc.
• Avoid mounting the detector near heat generating devices
(e.g. ovens, heat vents, furnaces, boilers) or on a metal
cabinet.
• DO NOT remove the circuit board from the back case.
IMPORTANT:
• Do not install this device on or near metal objects, Avoid
locating the device near wiring such as AC, telephone, HVAC,
computer data cables, etc.
• Avoid mounting the detector near heat generating devices
(e.g. ovens, heat vents, furnaces, boilers) or on a metal
cabinet.
• DO NOT remove the circuit board from the back case.
PROGRAMMING (Setting the Operating Mode)
PROGRAMMING (Setting the Operating Mode)
Table 1 lists the functions of the 5800FLOOD with their
respective loop numbers.
Program each desired loop function as a separate zone in the
control panel.
1. Enter the control’s Zone Programming mode.
2. Assign a zone number for each loop used.
Loop = 1, 2, or 3 (see table for loop functions)
Zone Type = choose a zone type based on desired operation
(ex. 24-Hr. Aux, Waterflow)
Input Type = 03 (Supervised RF)
3. When prompted for the serial number, press and release
the unit’s tamper switch twice.
Alternatively, you can manually enter the sensor serial
number found on the unit’s label.
Table 1
Table 1 lists the functions of the 5800FLOOD with their
respective loop numbers.
Program each desired loop function as a separate zone in the
control panel.
1. Enter the control’s Zone Programming mode.
2. Assign a zone number for each loop used.
Loop = 1, 2, or 3 (see table for loop functions)
Zone Type = choose a zone type based on desired operation
(ex. 24-Hr. Aux, Waterflow)
Input Type = 03 (Supervised RF)
3. When prompted for the serial number, press and release
the unit’s tamper switch twice.
Alternatively, you can manually enter the sensor serial
number found on the unit’s label.
Mode
Flood
Loop
Loop 3
Temperature
Cold
Hot
Fault Occurs When
After…
probe contacts water
40 sec
Temperature is..
Loop 1
below 45°F (7C)
Loop 2 above 95°F (35C)
Restore when …
no contact with water and
40 sec
contacts are dry
Temperature is..
above 45°F (7C)
15 min
After…
below 95°F (35C)
15 min
Table 1 (French)
Mode
Flood
Loop
Loop 3
Temperature
Fault Occurs When
After…
Restore when …
probe contacts water
40 sec
no contact with water and
40 sec
contacts are dry
Temperature is..
Temperature is..
below 45°F (7C)
Cold
Loop 1
Hot
Loop 2 above 95°F (35C)
After…
above 45°F (7C)
15 min
below 95°F (35C)
15 min
TESTING
TESTING
1. With the control panel in Test mode, remove & replace
device cover to activate.
2. System keypad should beep and display each programmed
zone (loop).
3. Exit control’s test mode.
1. With the control panelin Test mode, remove & replace
device cover to activate.
2. System keypad should beep and display each programmed
zone (loop).
3. Exit control’s test mode.
MAINTAINING PROPER OPERATION
MAINTAINING PROPER OPERATION
To maintain the detector in proper working condition, it is
important that you observe the following:
• Replace the battery when a low battery condition is reported.
• Make sure the unit is situated flat on the floor, or any other
surface and make sure the contacts are not blocked by debris
or dirt as these will affect conductivity of water in the area.
• Clean and dry the metal probes before reusing the device
following the water leak detection.
• It is recommended to get the advice of the alarm company to
relocate the device.
To maintain the detector in proper working condition, it is
important that you observe the following:
• Replace the battery when a low battery condition is reported.
• Make sure the unit is situated flat on the floor, or any other
surface and make sure the contacts are not blocked by debris
or dirt as these will affect conductivity of water in the area.
• Clean and dry the metal probes before reusing the device
following the water leak detection.
• It is recommended to get the advice of the alarm company to
relocate the device.
BATTERY REPLACEMENT
BATTERY REPLACEMENT
After removing the battery; wait at least 30
seconds before installing the new one. Use
only the following 3V Lithium batteries:
After removing the battery; wait at least 30
seconds before installing the new one. Use
only the following 3V Lithium batteries:
• Panasonic CR123A
• Duracell DL123A
• Huiderui CR123A
• Honeywell 466
• Panasonic CR123A
• Duracell DL123A
Attention de batterie : Risque d'incendie,
d'explosion et de brûlures. Ne rechargez pas,
démonter, chauffer au-dessus de 212° F (100°C),
ou incinérer. Débarrassez-vous des batteries
utilisées de façon appropriée. Gardez à partir des
enfants.
CAUTION: Risk of fire, explosion, and burns. Do
not recharge, disassemble, heat above 212°F
(100°C) or incinerate. Dispose of used batteries
properly. Keep away from children.
NOTE: Constant exposure to high or low
temperature or high humidity may reduce battery
life.
SPECIFICATIONS
Battery Type
Standby Current
Consumption
Low Battery Detection
Unit (Battery) Shut Down
RF Frequency
RF Range
3V Lithium, CR123A
(battery life ~4-5 years)
3µA maximum
2.8V ±20mV
1.8V ±20mV
344.94MHZ (5800 protocol)
200ft (60m) nominal indoors from
wireless transmitters (the actual
range to be determined with the
security system in the Test mode).
Operational Temperature 14°F to 104°F (-10°C to +40°C)
Cold- Hot Alert detection < 45°F for Cold, and ≥ 95°F for Hot
(<7.2°C for Cold, and ≥ 35°C for Hot)
Water Sensing Probes
Stainless steel contacts
Water Leak Detection
Reports alarm within 30-40 seconds.
Dimensions
3.1” L x 1.6” W x 2.0” D max.
(7.9cm L x 4.1mm W x 5.8mm D max.)
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE
CONTROL WITH WHICH THIS DEVICE IS USED, FOR
DETAILS REGARDING LIMITATIONS OF THE ENTIRE
ALARM SYSTEM.
• Huiderui CR123A
• Honeywell 466
NOTE : Une exposition constante à des
températures élevées ou basses ou à un taux
d'humidité élevée peut réduire la durée de vie de la
pile.
SPECIFICATIONS
Battery Type
Standby Current
Consumption
Low Battery Detection
Unit (Battery) Shut Down
RF Frequency
RF Range
3V Lithium, CR123A
(battery life ~4-5 years)
3µA maximum
2.8V ±20mV
1.8V ±20mV
344.94MHZ (5800 protocol)
200ft (60m) nominal indoors from
wireless transmitters (the actual
range to be determined with the
security system in the Test mode).
Operational Temperature 14°F to 104°F (-10°C to +40°C)
Cold- Hot Alert detection < 45°F for Cold, and ≥ 95°F for Hot
(<7.2°C for Cold, and ≥ 35°C for Hot)
Water Sensing Probes
Stainless steel contacts
Water Leak Detection
Reports alarm within 30-40 seconds.
Dimensions
3.1” L x 1.6” W x 2.0” D max.
(7.9cm L x 4.1mm W x 5.8mm D max.)
POUR LES DÉTAILS CONCERNANT LES LIMITATIONS
DU SYSTÈME DANS SON ENSEMBLE, REPORTEZ-VOUS
AUX INSTRUCTIONS D’INSTALLATION DU PANNEAU DE
COMMANDE AVEC LEQUEL LE DISPOSITIF EST UTILISÉ.
FCC / IC STATEMENT
FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's
Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC rules and Industry Canada’s license-exempt RSSs. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Unauthorized changes or modifications could void the user's authority to operate the equipment.
Cet appareil est conforme à la partie 15 des règles de la FCC & et exempt de licence RSS d’Industrie Canada. Son fonctionnement est
soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute
interférence reçue y compris les interférences causant une réception indésirable.
Support and Warranty / Soutien et Garantie
For online support information, please go to: https://mywebtech.honeywell.com/
Pour de l’assistance en ligne, visitez : https://mywebtech.honeywell.com/
For the latest warranty information, go to: www.honeywell.com/security/hsc/resources/wa
Pour les dernières informations de garantie, s'il vous plaît aller à :
www.honeywell.com/security/hsc/resources/wa
For patent information, see www.honeywell.com/patents
Pour des informations sur les brevets, voir www.honeywell.com/patents
Honeywell is a registered trademark of Honeywell International Inc. All
other trademarks are the properties of their respective owners. All
rights reserved.
Honeywell des marque déposée de Honeywell International Inc. Toutes
les autres marques de commerce appartiennent à leurs propriétaires
respectifs. Tous droits réservés.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
 2017 Honeywell International Inc.
www.honeywell.com/security
MyWebTech
Warranty
Garantie
Patents
Brevets
Ê800-23123jŠ
800-23123 8/17 Rev A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : EN-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Modify Date                     : 2017:08:16 11:47:01-04:00
Create Date                     : 2017:08:16 11:46:57-04:00
Metadata Date                   : 2017:08:16 11:47:01-04:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Document ID                     : uuid:cad40f6c-d6af-4d7a-ad90-e1ed24e50a49
Instance ID                     : uuid:a09cfa0a-8d47-4579-b797-5b34da1852b7
Subject                         : 37
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : Millien, Jean (S&FS)
Producer                        : Adobe PDF Library 11.0
Keywords                        : 
Source Modified                 : D:20170816154641
Company                         : Honeywell
Doc Index Ref                   : b8ea0dbd-6ba1-446f-9c7f-a8b92bdeeb13
Bj Saver                        : RTHabjDncQUIrFiViV8PDdlm+eM6fL4p
Bj Document Label XML           : 
Bj Document Security Label      : Honeywell Unrestricted
BJ Classification               : Honeywell Unrestricted
Page Layout                     : OneColumn
Page Count                      : 4
Author                          : Millien, Jean (S&FS)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CFS8DL5800FLOOD

Navigation menu